Analytical Spectroscopy Library - Volume 7
Applications of Synchrotron Radiation to Materials Analysis
Analytical Spectroscopy Library
A Series of Books Devoted to the Application of Spectroscopic Techniques to Chemical Analysis Volume 1 NMR for Liquid Fossil Fuels, by L. Petrakis and D. Allen Volume 2 Advances in Standards and Methodology in Spectrophotometry, edited by C. Burgess and K.D. Mielenz Volume 3 lntroduction to Inductively Coupled Plasma Atomic Emission Spectrometry, by G.L. Moore Volume 4 Sample lntroduction in Atomic Spectroscopy, edited by J. Sneddon Volume 5 Atomic Absorption Spectrometry. Theory, Design and Applications, edited by S.J. Haswell Volume 6 Spectrophotometry, Luminescence and Colour; Science and Compliance, edited by C. Burgess and D.G. Jones Volume 7 Applications of Synchrotron Radiation to Materials Analysis, edited by H. Saisho and Y. Gohshi
Analytical Spectroscopy Library - Volume 7
Applications of Synchrotron Radiation to Materials Analysis
edited by
H. Saisho Liaison Office, Faculty of Science and Engineering, Ritsumeikan University, Noji-cho 7916, Kusatsu, Shiga 525-77, Japan
and
Y. Gohshi Department of Applied Chemistry, Faculty of Engineering, University of Tokyo, 7-3-1Hongo Bunkyo, Tokyo 113, Japan
ELSEVIER Amsterdam - Lausanne - Oxford - New York - Shannon -Tokyo
- 1996
ELSEVIER SCIENCE B.V. Sara Burgerhartstraat 25 P.O. Box 21 1,1000 AE Amsterdam, The Netherlands
ISBN 0 444 88857-8
O 1996 Elsevier Science B.V. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of the publisher, Elsevier Science B.V., Copyright & Permissions Department, P.O. Box 521, 1000 A M Amsterdam, The Netherlands. Special regulations for readers in the USA. This publication has been registered with the Copyright Clearance Center Inc. (CCC), 222 Rosewood Drive Danvers, M A 01923. Information can be obtained from the CCC about conditions under which photocopies of parts of this publication may be made in the USA. All other copyright questions, including photocopying outside of the USA, should be referred to the copyright owner, Elsevier Science B.V., unless otherwise specified. No responsibility is assumed by the publisher for any injury and/or damage to persons or property as a matter of products liability, negligence or otherwise, or from any use or operation of any methods, products, instructions or ideas contained in the material herein. This book is printed on acid-free paper Printed in The Netherlands
Preface This book is a part of the series "Analytical Spectroscopy Library" and is devoted to X-ray analysis by synchrotron radiation. X-ray analysis is one of the oldest and most well established techniques in analytical chemistry. The method, however, is still on the leading edge of instrumental analysis. X-rays are nonrestrictive and can be tuned to a very sharp bandwidth. Their very short wavelength enables high resolution imaging down to a molecular or atomic scale. These potential capabilities are not well realized in current X-ray analytical instruments. The largest drawback is the low intensity of an X-ray source. Recent developments in the synchronotron radiation (SR) X-ray source are the real breakthrough, and the photon deficiency problem is now being solved. The number of SR facilities, however, is limited and their distribution is not uniform in the world. Whereas research reports are circulated in the US and EU countries very well, reports from the orient are often inaccessible due to language barriers. This volume is intended to describe various facets of X-ray analytical methods by SR with some emphasis on Japanese activity. The editors hope that this volume will provide general perspectives of X-ray analysis by SR, with the added spice of Japanese activity in the Photon Factory and the future Spring-8 project. Chapter 1 (Mititaka TERASAWA and Motohiro KIHARA) is a concise introduction to synchrotron facilities and the related basic instrumentation. The chapter will be helpful to understand the discussion of machine operators and technicians and to communicate with design people in the planning of a new ring or an insertion device. In chapter 2 (Hideo SHAISHO and Hideki HASHIMOTO), X-ray fluorescence analysis is discussed. SR provides tunable excitation which is very effective in improving a detection limit (DL). The detailed discussion on DL is based on a theoretical estimation of background and the discussion can be extended to future research planning. Another important characteristic of SR is natural collimation, which leads to total reflection analysis. The theoretical treatment in this chapter will be especially useful for thin layer analysis by XRF. Chapter 3 (Shinjiro HAYAKAWA and Yohichi GOHSHI) covers microbeam and chemical state analysis. Instrumentation for microbeam optics is completely dependent on the fabrication technology of optical components which are state of the art. Xray analysts, however, can expect better performance of a microbeam optical system with the knowledge of optical systems described in this chapter. In addition to its imaging capability, an energy tunable microprobe can speciate analytes. Several sophisticated applications are discussed. Chapter 4 (Hiroyuki OYANAGI) covers X-ray absorption fine structure, which is the most widely used technique in the application of SR to material analysis. Instrumentation
in the detection system is included together with a general description of XAFS and a variety of applications.
Chapter 5 (Toshiaki OHTA, Kiyotaka ASAKURA and Toshihiko
YOKOYAMA) covers surface structural analyses.
Surface sensitive signal detection is
described, followed by SEXAFS and NEXAFS applications to surface phenomena. Other important techniques such as surface diffraction, standing wave, and angle resolved photoemission fine structure are also explained together with several applications. Chapter 6 (Kanji KAJIWARA and Yuzuru HIRAGI), Structure Analysis by Small-angle X-ray Scattering, describes the powerful traditional method for organic molecules, especially polymers. Chapter 7 (Fujio IZUMI) explains details of the Rietveld method and its applications to synchrotron X-ray powder diffraction data. The author has developed much software for the Rietveld method and his experience contributes to the comprehensive description given in this chapter. Chapter 8 (Katsuhisa USAMI) and Tatsumi HIRANO), Xray Microtomography deals with large scale structural analysis. Energy tunability of the SR X-ray source adds even more elemental and chemical state information to the tomographic image of information. Though there is still a gap between atomic scale structural analysis and mm or pm analysis, this will be bridged by the future SR X-ray method. The editors H.S. and Y.G. hope that this volume will be of help to research scientists and students who are interested in materials analysis by X-ray methods. H.S. and Y.G. finally appreciate the effort and patience of all the authors and the staff at Elsevier Science. February 1996 Y. GOHSHI H. SAISHO
CONTENTS Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1. Basic characteristics of synchrotron radiation and its related facilities and instrumentation by M. Terasawa (Hyogo 671-22, Japan) and M. Kihara (Ibaraki 305, Japan) . . . . . . . . . 2. X-ray fluorescence analysis by H. Saisho and H. Hashimoto (Shiga 520, Japan) . . . . . . . . . . . . . . . . . . . . . 3. Microbeam and chemical state analysis by Shinjiro Hayakawa and Yohichi Gohshi (Tokyo 113, Japan) . . . . . . . . . . .
4. X-ray absorption fine structure by H. Oyanagi (Ibaraki 305, Japan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. Application to surface structure analyses by T. Ohta, K. Asakura and T. Yokoyama (Tokyo 113, Japan) . . . . . . . . . . . . . . . . . . 6. Structure analysis by small-angle X-ray scattering by K. Kajiwara (Kyoto 606, Japan) and Y. Hiragi (Kyoto-fu 61 1, Japan) . . . . . . . . . . . 7. The Rietveld method and its applications to synchrotron X-ray powder data by F. Izumi (Ibaraki 305, Japan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8. X-ray microtomography by K. Usami and T. Hirano (Ibaraki 3 19-12, Japan) . . . . . . . . . . . . . . . . . . . . .
Subject index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
This Page Intentionally Left Blank
Applications of Synchrotron Radiation to Materials Analysis H. Saisho and Y. Gohshi (Editors) 9 1996 Elsevier Science B.V. All rights reserved.
CHAPTER 1
BASIC C H A R A C T E R I S T I C S OF S Y N C H R O T R O N R A D I A T I O N AND ITS RELATED FACILITIES AND INSTRUMENTATION Mititaka T E R A S A W A Himeji Institute of T e c h n o l o g y 2167 Shosha, Himeji, H y o g o 671-22, Japan
Motohiro KIHARA National L a b o r a t o r y for H i g h E n e r g y Physics ( K E K ) Oho, T s u k u b a , Ibaraki 305, Japan
1.1. I N T R O D U C T I O N Electromagnetic radiation emitted by charged particles when they move at a highly relativistic velocity on a circular orbit is called synchrotron radiation, or SR in s h o r t - which was named after the first observation of the radiation in an electron circular accelerator, a synchrotron. Although the synchrotron radiation was, in its early history, considered simply to be a useless and harmful by-product generated in circular accelerators, it has become of great interest and is utilized in materials science as an intense and versatile photon source. At the beginning, the radiation was used as a powerful photon source for spectroscopy in the wavelengths ranging from soft X-rays to the vacuum ultra-violet (VUV). From the early 1960s many of the existing electron synchrotrons in the several hundred MeV class have been modified and turned over to synchrotron radiation facilities. In the mid 1970s, an electron storage ring became a normal photon source facility, in place of the electron synchrotron. The storage rings were originally developed for collision experiments in high energy physics. In the electron synchrotron, electrons are accelerated and, after the maximum energy is achieved, are extracted, usually at a rate of several tens per second. In
contrast, in the storage ring the previously accelerated electrons are injected into and stored in the ring orbit. As a consequence this is greatly superior to the former synchrotron as an intense and stable radiation source. Recently large storage rings in the multi-GeV class have been developed and the wavelengths of the radiation have been extended to the hard X-ray range. The use of such high energy X-rays is now having a great impact in studies on X-ray scattering, diffraction, inner shell ionization, and even nuclear excitation. Nowadays the usefulness of synchrotron radiation is well recognized in various research fields, and many storage tings dedicated to synchrotron radiation research have been constructed or are currently under construction. Moreover, insertion devices, which allow radiation of much higher brilliance to be obtained, are well developed and available as practical facilities. The synchrotron radiation is usually emitted by electrons moving in a circular orbit in the bending magnet. The radiation from insertion devices such as the undulator and the multipole wiggler, which are positioned on the straight section of the storage ring, is of extremely high brilliance - - and also has a shorter wavelength with multipole wigglers than with bending magnets. The storage tings of recent advanced synchrotron radiation facilities are designed to have many long straight sections so as to accommodate such insertion devices as low emittance and high brilliance photon sources. Consequently, the tings always tend to become larger.
1.1.1. Properties of Synchrotron Radiation Electrons submitted to an acceleration field emit electromagnetic waves. This phenomenon is well recognized in a classic antenna where the electrons are travelling in conducting wires, the acceleration is very weak, and the emission takes place in the radiofrequency range. With vacuum electron tubes, such as the klystron, it is possible to increase the acceleration on electrons which are travelling in the vacuum, and to push the emission into the ultra-high frequency (UHF) range. In these tubes the electron energy is fairly weak. In circular high energy electron accelerators,~with electron energies up to several giga electron volts (GeV), the magnetic field in the bending magnets induces a very strong centripetal acceleration in the highly relativistic electrons, with an energy E >> m c 2 where m is the rest mass of electron. The acceleration induces an electromagnetic wave emission up to several hundreds keV in the most energetic machines. This radiation is called synchrotron radiation. Relativistic positrons also emit synchrotron radiation in the magnetic field by the same principle. Thus, circular electron- and positron-accelerators and storage rings, in which the particles move with relativistic energies, have become man-made sources of synchrotron radiation. The radiation source is basically composed of three component facilities: a linear accelerator, the synchrotron and the storage ring. Electrons are injected into an electron synchrotron at a relatively low energy, say several hundred MeV, from the linear accelerator. They are then accelerated on a fixed circular orbit. The synchrotron consists of an array of magnets for focusing and bending the electron beam, and straight linear sections for accelerating the
particles. The magnetic field in the deflecting magnets is increased during the acceleration in order to keep the electrons on the same circular path as their energy is gradually increased. Finally, when they reach the appropriate energy, the electrons are transferred to the storage ring. Here the magnetic field remains constant. There are acceleration sections within the storage ring which compensate for the energy losses due to synchrotron radiation. Around the storage ring the radiation from the stored electrons can be used for various experiments. This photon production is of extreme interest for spectroscopy. Synchrotron radiation has a number of outstanding properties: (1) A continuous spectrum from the infrared to the X-ray region. (2) High intensity, owing to the high current electrons accumulated in the storage ring. (3) Collimation of the emitted radiation in the instantaneous direction of flight of the emitting particles (the angular spread is of the order of 1 mrad). (4) Linear polarization, with the electric vector parallel to the plane of the orbit. (5) Circular polarization above and below the plane of the orbit. (6) High brilliance of the source, because of the small cross section of the electron beam and the high degree of collimation of the radiation. (7) A time structure with pulse lengths down to 100 ps. (8) Absolute calculability of all the properties of the source. (9) Cleanliness of the source, since the light emission takes place in an ultra-high vacuum, in contrast to the situation in gas discharge or spark lamps. 1.1.2. Historical Remarks Although synchrotron radiation was first observed directly by Elder and his co-workers [1] at the General Electric 70 MeV synchrotron in 1947, the theoretical consideration of radiation by charged particles in circular motion goes back to the work of Lienard in 1898 [2]. Further theoretical work was made by Schott [3], Jassinsky [4], Kerst [5], Ivanenko and Pomeranchuk [6], Arzimovitch and Pomeranchuk [7] and others through to 1946. Blewett [8] was one of the first to be concerned with the effects of the radiation on the operation of electron accelerators and he observed the effects on the electron orbit in 1945, although he did not detect the radiation itself. After the observation of the radiation by Elder and his co-workers in 1947 the interest in synchrotron radiation was renewed. Comprehensive theoretical treatments were presented by Sokolov and his co-workers [9] and by Schwinger [10] in the late 1940s and later. With these works the theory was fully developed so that accurate predictions could be made regarding the intensity, spectral and angular distributions, polarization, and so on. Following the first observation Elder and his co-workers carded out experimental investigations in the late 1940s on the properties of the radiation, using the General Electric 70 MeV synchrotron. In the 1950s studies of synchrotron radiation were extended by several groups [11], using the 250 MeV synchrotron at the Lebedev Institute in Moskow, by Corson [12] and Tomboulian and
his co-workers [13] using the Comell 300 MeV synchrotron, and by Codling and Madden [14] using the 180 MeV synchrotron at the National Bureau of Standards (NBS) in Washington D.C. In the mid-1960s Haensel and his co-workers [ 15] were the first to utilize radiation from a multi-GeV accelerator, the 6 GeV synchrotron in Hamburg. The investigations mentioned above confirmed the basic theoretical predictions and provided much useful data and experience in the use of the radiation.
1.2. PRINCIPLE OF SYNCHROTRON RADIATION EMISSION 1. 2. 1. Principle of Synchrotron Radiation Emission The properties of synchrotron radiation (SR) can be derived by applying the methods of classical electrodynamics to the motion of relativistic electrons and positrons in circular orbits. Hereafter we confine the following discussion to the radiation emission only by electrons, because the principle of the emission by positrons is the same. First of all, we consider the circular motion of an electron with momentum p in a magnetic field B. The radius of the electron orbit, p, is given by the following equation. pc = Bep
(1-1)
where e is the electron charge and c is the speed of light. For relativistic electrons, E 2 = p 2 c 2 + m 2 c 4 ~ p2c2
(1-2)
where E is electron total energy and m is the electron rest-mass. From Eqns. (1-1) and (1-2), E = Bep
(1-3)
This relation is described using practical units, by Eqn. (1-4). B[tesla] p[m] = 3.336 E[GeV]
(1-4)
Angular distribution of SR When an electron is non-relativistic (fl = v/c << 1) and the velocity is significantly low compared to the speed of light, the electron on a circular orbit is accelerated toward the center of the orbit, and emits a dipole radiation whose axis is in the direction of the acceleration. The radiation power per unit solid angle, which is the energy of the electromagnetic wave emitted in unit time from the electron with the acceleration of dv/dt, is given by
d P ( z ) = e 2 (~t)2sin2z dO 4~rc 2
(1-5)
where Z is the angle between the directions of the acceleration and electromagnetic wave transmission. Therefore the angular distribution of the radiation power based on a dipole radiation shows the typical pattern of sin2z. As shown in Fig. 1-1, the radiation emission is at maximum in a direction normal to the acceleration (2' = 7r/2), and there is no emission at the two acceleration directions of Z = 0 and 27 = 7r.
dv
-Orbit- - - . . . . ~
Acceleration /--~~)~'~Ujt
)
at
'J
To
v
spectrograph
(a)
(b)
Fig. 1-1. Radiation patterns of electrons in circular motion at low velocity.
K
K' P
,-x-(x, y, z, t) (x', y', z', t')
vt
Otl
Z "JI
Z'
I
Fig. 1-2. Coordinate systems showing Lorentz transformation. Electrons moving at the velocity v are on the system K', and the radiations are observed on the system K. When an electron moves near the light speed, the properties of SR from the electron are described by relativistic electrodynamics. If an observer is in a fixed coordinate system located on the electron, he observes the same angular distribution of sin2z as for the non-relativistic
case mentioned above, even if the electron moves relativistically. However, if an observer is in the stationary coordinate system, the angular distribution becomes distorted due to the relativistic effect. Let us take a stationary coordinate system K(x,y,z,t), and another coordinate system K' (x ',y ",z ',t ") which is moving at speed v along the direction of the z axis. The relationship between the two systems is given by the Lorentz transformation,
z = 7(z' + vt') X ' - X'
y=y' t = 7 (t' + flz'/c)
(1-6)
where fl = v/c and, 1
r 41_/32 _
(1-7)
E
(1-8)
mc 2
= 1957 E[GeV]
(1-9)
Here, ?'is the energy of the electron represented in units of the electron's rest mass energy, that is mc 2 = 511 keV. For example, fl = 0.999999868 and ?' = 1957 for E = 1.0 GeV. The electron mass becomes 1957 times the rest mass, which means that the acceleration of relativistic particles increases the mass, while changing the velocity little, because it is almost the speed of light. As shown in Fig. 1-2, if the SR, which is emitted at angle 0 ' from the z' coordinate from an electron fixed at the K' system is observed at angle 0 from the z coordinate, the following relationship is obtained, using the Lorentz transformation for velocity.
cos0'+ fl
COS0 =
1 + fl c o s O '
(1-10)
sinO'
sin0 =
y(1 + fl cosO')
(1-11)
then, tanO=l
sinO'
? ' c o s O ' + fl
(1-12)
The angle 0 ' = + nr/2 in the K' system, at which no radiation is emitted, is proved to correspond to 0 = + 1/Tin the K system, according to Eqn. (1-12). The sin2z angular distribution of radiation emission is extremely distorted and a forward focusing, in which the radiation is concentrated within a sharp cone with its axis tangential to the electron circular orbit, is observed, as shown in Fig. 1-3.
....
Orbit . . . . .
Acceleration
dv dt
,
To"
V
(a)
spectrograph
(b)
Fig. 1-3. Radiation patterns of electrons in circular motion at velocity approaching that of light. The root mean square (r.m.s.) of the radiation emission angle, which corresponds to half the cone angle, is expressed as follows for the radiations near the emission spectrum center; (i//2)1/2 = 1 7
(1-13)
For example, 1/7 = 0.064 mrad for E = 8.0 GeV, which means only 6.4 mm spread of the radiation 100 m from the source point. It is understood that the SR is an ideal collimated beam. Actually, the intensity of the radiation drops rapidly with increase in the angle ~ i n the direction vertical to the electron orbit plane, while the plane is filled with the radiation because electrons are emitting their radiation all the way round.
Spectra In the case when an electron moves non-relativistically on a circular orbit with radius p, an angular frequency of radiation is equal to an electron revolution frequency, coo = v/p. When an electron moves relativistically, the main frequency components of the radiation are significantly
higher harmonics of the revolution frequency too. Let us consider an observer standing on a line tangential to the electron orbit, as shown in Fig. 1-4. The observer will be subjected to the radiation which is emitted by the electrons moving between A and B on the circular arc, the length of the arc being 2p/7' because the radiation emission angle is about 2/7,. The time interval of the radiation to which the observer is exposed will be the time that the radiation travels from A to B, subtracted from the time that the electron moves along the arc AB, that is, 2p At = v)'
2p sin~ 2p c = -U~-(c - 1)
(1-14)
Adopting
v/c = fl= 1 - 1/(2 7' 2) At=
p = C7' 3
(1-15)
1
(1-16)
too7' 3
The radiation is confined to an extremely short pulse, since this time interval is in inverse proportion to ),3. For example, At = 3.48 x 10-20 sec in the case of E = 8.0 GeV and p = 40.1 m.
observer
Fig. 1-4. Electrons in circular motion and synchrotron radiation emitted by the electrons in a tangential direction. An electric field of pulsed radiation as a function of frequency, E(to), is derived as the Fourier transformation of the time-dependent electric field, E(t). The power-spectrum of SR is determined by E(to) 2. In the present case, E(t) is a periodic pulse with the pulse width of
p/(c7"3), and the pulse interval 27rp/c, as shown schematically in Fig. 1-5a. The quantity E(to) 2 consists of a vast number of higher harmonics of the basic angular frequency too = c/p,
as shown in Fig. 1-5b. The frequency tOp of the major parts in the power-spectrum is determined from Eqn. (1-17). 2--~ = 2~ y3 too top = At
(1-17/
IJJ
q 2r~p
t
C
(a)
coo
Ill
._ v
~p
(b)
Fig. 1-5. Synchrotron radiation (SR) emitted by electrons in circular motion. (a) Time variation of the electric field induced by SR. (b) Spectrum of the radiation power. The spectrum is understood to include extremely high order Fourier components. While the whole spectrum consists of many spectral lines with the interval of too, it actually becomes a continuum because of the energy fluctuation of electrons caused by emitting radiations. Thus the wavelength spectrum extends widely from the infrared to the X-ray region. We use a critical (or characteristic) angular frequency toc as a parameter characterizing the power spectrum, that is,
toc = ~ 'Y 3 600
(1-18)
This parameter is defined to be an angular frequency at which the power spectrum is divided equally. A critical wavelength, ~,c, is then defined as Ze = 27rc = 4 ~
toc
3
P
~,3
(1-19)
Using practical units, A,c[A] = 5.59
p[m] _ 18.6 E 3 [GeV] E 2 [GeV] B [tesla] n
Also, a critical energy, e c, is defined by
(1-20)
I0 hc
(1-21) = 12.4 _ 2.22E3[ GeV] ee [keV] Ac[A] p[m]
(1-22)
For example, for E = 8.0 GeV and p = 40.1 m, the basic angular frequency is 090 = 7.48 x 106/sec = 7.48 MHz, and the critical angular frequency becomes o9c = 4.31 x 1019/sec. The critical wavelength Zc = 0.438 A, and the critical energy ec = 28.3 keV.
Polarization An electric field vector of an electric dipole radiation is represented by the sine-squared angular distribution as shown in Figs. 1-1 a and 1-1 b. The radiation emitted by an electron in the plane of its orbital is completely polarized, with the electric vector parallel to the orbital plane. Above and below this plane the radiation is elliptically polarized, to a degree determined by the viewing angle.
-
-
Orbit
~>0
'.-z.... ~
"
Accele "~--"O
-..
.~M
(a)
T
s S
SSS
~
~'~
~
e
v
(b)
Fig. 1-6. Polarization of synchrotron radiation. For emission in the orbit plane the electric vector lies in the plane, and for emission at some angle gt with respect to the orbit plane the vector also has a component normal to the parallel component. The polarization can be understood as a change of the acceleration vector being applied to an electron during its circular motion, as shown in Fig. 1-6. If an observer standing near a tangent line at the radiation source point traces the changing vector, the polarization is decided according to the locus of the vector. When the observation is made at 1g = 0 on the orbital plane, the
11 acceleration vector locus is always on the horizontal plane, and the radiation is linearly polarized. On the other hand, when the observation is made at gt > 0 and gt < 0, being off the plane, the acceleration vector locus is elliptical, and elongated in a horizontal direction, and the radiation has elliptical polarization. The rotation of the polarization is inverted for ~ > 0 and gt <0.
Coherency As we will discuss later (see Section 1.6. INSERTION DEVICES), if an undulator is employed in the storage ring, coherent radiation with an extraordinarily higher brightness is obtained. However, with a normal bending magnet, the radiation is incoherent, especially in the shorter wavelength range. Therefore the intensity is the total of the radiation emitted by each electron.
1. 2. 2. Basic Equations of Synchrotron Radiation
Radiation induced by electrons First of all we may take the Larmor formula for the power radiated by a single non-relativistic electron with mass m and charge e. The formula is obtained by integrating Eqn. (1-5) over solid angle, and is described as follows; e2/dv/2=2 e 2 /dp/2 W = 2--~ ~dt ! 3 n ~ 3 ~dt l
(1-23)
For a relativistic electron in circular motion, Eqn. (1-23) is rewritten by replacing the momentum p by an four dimensional momentum vector (P, iE/c), where P = TP. Adopting an intrinsic time ds =dt/?', e 2 //dP/2 1 /dE/2~ W = ~ m2c3 |~~s ] - ~ ~-~S] | _ 2 e___L_ 2
I(dPl2
- 3 m2c 3 ),2 I~ dt !
l/dE/2t
7~ ~-~! |
(1-24)
In a circular accelerator, the change of E with time is negligibly small compared to the change in p, and the second term in the bracket in Eqn. (1-24) is neglected.
d---PI2= r2 m2/0v dt !
~dt !
12
= ,y2 m 2 (evB~ (1-25)
= ~, 2 m 2 c4[p2
Eventually, W [erg/sec/electron] = ~_~_~__ ? ,2C e
4 (1-26)
Total radiation power is proportional to ~,4, i.e. E 4 , and inversely as p2. Eqn. (1-26) is the Larmor formula for a relativistic electron in circular motion. Radiation power and photon number
Schwinger [ 10] has provided the expression for the instantaneous radiation power (C.G.S. units) emitted per unit wavelength and per radian (in vertical angle gr by a monoenergetic electron in circular orbit: d2W Ierg/sec/rad(vertical)/cm/electron] d I/td~ -32tr3 p3
)'8{1+(?'1/~}2 K2/3(~)+ (~'l/t)2 K2/3(~) 1+()' V)2
(1-27)
where ~ = Ac { 1+(]~r and K1/3 and K2/3 are modified Bessel functions of the second kind, gt is the angle between the direction of photon emission and the instantaneous orbital plane, and A,c is the critical wavelength given by Eqn. (1-19). It is noted that the angular spread of the radiation is dependent on the wavelength. If ~, is in the vicinity of ~,c, the spread Agtis almost 2/7, as given in Eqn.(1-13). If ~ is far from A,c, the spreads are given by [I],11/2
Agt--- t2~3~1
AV =
' for ~, << Ac
, for ~ >> ~,c
(1-28)
(1-29)
The angular distribution becomes sharp as the wavelength decreases, in general. For ~, << ~,c, the distribution tends to a smaller angle than 2/7', while, for A, >> A,c, it spreads to a larger angle than 2/?,, and approaches a shallow dip at gt = 0 (see Fig. 1-7).
13 A representation of a photon number is sometimes useful instead of the powers expressed by Eqn. (1-27). The photon number is given as follows, by dividing the power by single photon energy, hc/L d3N [photons/sec/rad(vertical)/cm/electron] dtdvd,~ -87r 2 h /92 ~, 3{1+(~#')2}2
:o. 97
1+(~) 2
(1-30)
{
(1-31)
Assuming the electron beam current in storage ring is J, the number of electrons emitting the radiation is given by n
=
27rp j ec
(1-32)
= 1.31 • 1011 p [m] J[amp]
(1-33)
The photon number for the beam current of J [amp] is calculated by multiplying n to Eqn. (130). For the emission angle of 1 mrad in the electron orbital plane and 1 mrad in the direction vertical to the orbital plane, multiplying 10-6/27r by the Eqn. (1-30) gives the photon number. When 0.1% of band-width is adopted as a wavelength width, multiplying AA = 0.001~ = 0.001 x 47r/3 x 102 p[m]/y 3 x A/~c gives the corresponding photon number. Eventually, the number of photons per sec in 1 mrad 2 of solid angle, 0.1% band width, and a beam current of 1 mA is given by d3N [photons/sec/mrad2/0.1% b.w./mA] dtdl2dA,/& = 3.46 x 103 'J,'2
K22/3(~)+
1+('Bg)2
K2/3(~) (1-34)
This photon number is called a "brightness". Figure 1-7 shows an example of the angular distribution of photon number for various wavelengths [16]. As mentioned above, the shorter the wavelength, the smaller is the angular spread. In the orbital plane V = 0, Eqn. (1-34) is reduced to
14
d3N
]
dt d,QdMA, lqr=o
= 3 . 4 6 x 103 yg(Xc]2~"2 [~,c
-~--~] ~ 2/3~-~]
(1-35)
~d' 1
=
1oooA
.
--
I
r
.
.
.
.
.
.
l 1A
|
Azimuthal angle
.
.
.
.
.
~ (mrad)
Fig. 1-7. Angular distribution of SR. Photon number as a function of perpendicular angle V, calculated for the wavelength of radiations at E = 2 GeV and p = 5.55 m [16]. 1 014 <
E 013
d
E ~1
~
012
01 ~
,,_..
n'-
101~ 1 00.01
0.1
1
10
1 O0
E n e r g y , KeV 1 1000
I
100
I
10
I
1
I
0.1
1000 9
I
,,
0.01
Wavelength , A
Fig. 1-8. Typical spectral distribution of SR. Brilliance as a function of photon energy for (a) PF (E = 2.5 GeV, p = 8.66 m) and (b) SPring-8 (E = 8.0 GeV, p = 40.1 m). Examples of spectral distribution at V = 0 are shown for the cases of E = 2.5 GeV, p = 8.66 m (PF ring ), and for E = 8.0 GeV, p = 40.1 m (SPring-8) in Fig. 1-8. When Z =/2c, K2/3(!/2) = 1.206 and the photon number is given by
15 d3N
)
-
03
dtd-~MA ~o,Z=Z~- 5.04 x 1
y
2 (1-36)
Spectral distribution The spectral distribution of the radiation power is reduced by integrating Eqn. (1-27) over all vertical angles. dW[erg/sec/cm/electron] = 35/2 e2c r 7 aa(y) d~, 16n:2 p3
(1-37)
dW [erg/sec/~Jelectron] = 6.83 x 10 -24 7 7 G3(y) d~, p3Em]
(1-38)
y=~,c = e _ ec
(1-39)
or
where,
Here, G3(y) is the formula for n = 3 of Gn(y), which has been provided by Green [ 17].
Gn(y) = ynGo(y), G0(y) =
K5/ 3(r/ )d r/ (1-40)
where/(5/3(r/) is a modified Bessel function of the second kind. The values of various Bessel functions and integrals as a function of V are given in the Appendix of this chapter. Figure 1-9 shows the curves of Gn(y) for n - 1, 2, and 3 as a function of y. The radiation power spectrum is decided by G3(y), which has a maximum value of 1.24 and a fwhm of 0.84 ~,c, when y - 2.35, i.e.,/1, = 0.425 Ac. The radiation power for the electron beam current of 1 mA is represented by dW [erg/sec//~/mA] = 8.94 x 10-16 y 7 G3(y) dA p2[m]
(1-41)
Moreover, the power for the emission angle of 1 mrad in a horizontal direction is represented by dW [erg/sec/mrad(horiz.)/]k/mA] = 1.42 x 10 -19 ~t 7 G3(y) d0dZ p/Em]
(1-42)
16 where 0 is an angle in the horizontal direction. By dividing Eqn. (1-37) by hc/&, the power is converted to the photon number. d2N [photons/sec]cm/electron] = 33/2e 2 it 4 G2(y) dt dA, 47rh /92
(1-43)
d2N [photons/sec//~/electron] = 1.44 x 10- 5 ~,4 G2(y) dt dA, /921111]
(1-44)
or
101
I -
'
.......
I
'
.......
I
1 0~
........
I
'
' '''"1
:
1 0 -1
1 0 -2
1 0 -3
0.1
I
Fig. 1-9. Curves of Gn(y) for n
10
1/y = 1, 2 a n d
3.
100
1000
The radiation power spectrum is decided
by G3(Y). The photon number spectra is decided by G2(y), which is shown in Fig. 1-9. G2(y) has a maximum value 0.683 at y = 1.32, i.e., ~ = 0.76 2c, and has a fwhm 2.3 ~ . The photon number for an electron beam current of 1 mA is given by d2N [photons/sec/,2k/rnA] = 1.88 x 103 ~' 4 Gz(y) dt d,~, p2[m]
(1-45)
and the number for the emission angle of 1 mrad in a horizontal direction is given by d2N [photons/sec//~/mrad(horiz.)/mA] = 3.00 x 10-1 y4 G2(y) dtd0d~, p2[m]
(1-46)
17 Moreover, the photon number for a band width of AZ = 0.001 g is given by d3N dtdOdZi-----------~[photons/sec/mrad(horiz.)/O.l% b.w./mA]
=
1.26 x 107 ?'GI(y)
(1-47)
The photon number represented by Eqn. (1-47) is called "flux".
2 "~
1 02
..................... ~.............................. ~..................... p..................... .=..................... .
, oo
...........1 0 .
.
.
.
.
.
.
p=,i6m
10-2
10.4
~.
10s
10 -e 0.001
0.01
0.1
;~
1
10
(A)
1 O0
1000
Fig. 1-10. Spectral distributions of synchrotron radiation represented by the radiation power for various electron energies at an electron orbiting radius of 40 m. 1 0e
......................... ; ........................ ! ........................................................................ i i ~
o~
1 05
103 0.01
0.1
1
~(A)
10
100
1000
Fig. 1-11. Spectral distributions of synchrotron radiation represented by the photon numbers for various electron energies at an electron orbiting radius of 40 m.
18 The flux spectra depend on G l(y), shown in Fig. 1-9. G l(y) has a maximum value 0.92 at y = 0.29, i.e., ~, - 3.4 ~,c. The photon number at peak in the flux spectra is calculated by - d3N -
dtdOdM~,
[photons/sec/mrad(horiz.)/0.1% b.w./mA] = 1.16 x 107 ~'
(1-48)
Figures 1-10 and 1-11 are the spectral distributions of the radiation power and the photon number, respectively, showing the wavelength dependencies for various electron energies at a definite electron orbiting radius. The power and the photon number have remarkably wide spectral ranges of wavelength, and broad peaks. With an electron energy increase the peak shows an increase in the amount of power and the photon number, and a shift to shorter wavelength. The spectra have sharp cut-offs in the shorter wavelength range where both the power and photon number decrease steeply with increasing electron energy. In long wavelength range both spectra show gradually decreasing characteristics which is not likely to change much with electron energy.
Polarization The radiation is predominantly polarized with the electric vector parallel to the acceleration vector. The two terms in the last bracket of Eqn. (1-25) are associated with the intensities in the two directions of the polarization, Ip and I N, having the electric vector parallel and normal to the orbital plane, respectively. Figure 1-12 shows the angular distribution of the two components [ 18]. As is evident in Fig. 1-12a, the parallel component Ip has a sharp peak at ~r = 0 on the plane, while the normal component I N is zero at V = 0 and has small peaks above and below the plane (V > 0 and gr < 0). A degree of linear polarization Pl is defined as follows, /p - IN Ip + IN
Pl = ~
(1-49)
K~/3 (~) _ (]i i11)2 K2/3 (~)
l+(rv)
(1-50) Fig. 1-12b shows P l as a function of ~. At gr = 0, the radiation is of complete linear polarization and Pl = 1 (100% polarization). As I~ increases, PI decreases. Since the two components of the electric vector have a well defined phase relationship with respect to each other, namely +n/2 or-~/2 above or below the orbital plane, there is a degree of
19 circular polarization, Pc, with the decomposition of the elliptically polarized wave into rightand left-hand waves with intensities I R and I L, respectively. p c = IR - IL = +_ 1lip IN
IR + IL
Ip + IN
(1-51)
The positive and negative signs correspond to gt > 0 and gt < 0, respectively. As is evident in Fig. 1-12c, the circular polarization, Pc, is 0 at gt- 0. As I~ increases, the radiation tends to the circularly polarized condition, Pc - 1, although the total intensity decreases rapidly. e = 10 eV
"1 ~
e = 1 O0 e V
~1
+
e = 10000
'
eV
'
.__
m
(a)
g
.s 0 " " .....
0--
~...
"~
I
--2 0
I
-2
2
.9
'~ .+
-o "iI__ 0
t'-
-1
_!
1.
.
.
.
2 0
.~
.;
.I
.2
.9
(c)
.I..J
" "
-~.,
.s
0
I
V
(mrad)
2 o
u
•
I
1
(mrad)
2 0
V
(mrad)
Fig. 1-12. Angular distribution of intensity components with electric vector parallel (Ip) and normal (IN) to the plane of the synchrotron, linear polarization and circular polarization (from decomposition into left (IL) and fight (IR) hand circularly polarized components) for a storage ring with p = 12.12 m and an energy of E = 3.5 GeV calculated for three photon energies, gtis the electron angle perpendicular to the orbital plane [17]. By integrating Eqn. (1-27) over all wavelengths, the angular distribution of radiation power is obtained.
20 dW [erg/sec/rad(vertical)/electron] d~
=e2Cp275{1+(71//)2}-5/2 {1-7-6 - + 165 1+(~/i}2_ (Tgt)~_ }
(1-52) In this formula, the first and second terms in the last bracket correspond to parallel and vertical component of the polarization, respectively. Integration of Eqn. (1-27) over all angles and all wavelengths yields about 75% polarization in the orbital plane. Total radiation power and total photon number Total number is obtained by integrating Eqn. (1-37) over all wavelengths and the result is in agreement with Eqn. (1-26). The energy which a single electron loses by emitting radiation during one turn is given by AE [erg/electron/tuml = c2ZP W= 4z ep]t42
(1-53)
If we adopt practical units, AE [keV/electron/tum] =
88.5 E 4 [GeV]
p[m]
(1-54)
When the electron beam current is J, the total radiation power is given by
W_4ze2 _ __~ __p__,ff 4 j
(1-55)
In practical units, W[kW] =
88.5 E 4 [GeW] J [anlp]
p[m]
= 26.6 E 3 [GeV] B [tesla] J[amp]
(1-56)
For example, in the case of E = 2.5 GeV and p = 8.66 m, AE = 399 keV/electron/tum and W = 120 kW for J = 0.3 amp. In the case o f E = 8.0 GeV a n d p =40.1 m, AE = 9.04 MeV/electron/tum and W = 892 kW for J = 0.1 amp. The radiation power per 1 mrad on the horizontal plane is calculated for a beam current of 1 mA, as follows:
21 dW [watts/mrad]mA] = 0.0141 E 4 [GeV] dO p[m]
(1-57)
Then, the total number of photons emitted per unit time per electron, by integrating Eqn. (1-43) over all wavelengths, is dNdt[photons/sec/electron]
_5 ~
ff'e2~z hp
(1-58)
Moreover, the photon number per electron per turn is given by AN [photons/electron/turn] = 2 z p dN = 5 z ot 7 c dt
(1-59)
where a = 2 ~ 2 / ( h c ) = 1/137 is the fine structure constant. Brightness and brilliance
Previously we discussed the radiation emission from an electron in ideal circular motion. In practice, since the electron in the storage ring moves in an equilibrium orbit with some amount of fluctuation in space and angle, some corrections are necessary for the exact calculation of the spectral and angular distributions and the degree of polarization of the synchrotron radiation. Let us take x- and y-axes in the plane perpendicular to the tangent direction (z-axis) of a circular orbit, as shown in Fig. 1-13. Assuming that the electron beam has a Gaussian distribution in the xy-plane, and the standard deviations of the spatial distribution are represented by crx and Cry in the x- and y-directions, respectively, then the cross section of the electron beam, i.e., the size of the radiation source, is 2.352 Crx Cry (because the full width at half maximum is 2.35 times the standard deviation). The extents of angular distribution are also similarly represented by the standard deviations of Crx' and Cry'. The values of crx, Crx', Cry and Cry' are variable, depending on the location along the electron orbit. However, there is an interrelation between Crx and Crx', and also Cry and Cry'. We define an emittance ex and ey as follows, Ex = axax'
(1-60)
ey = Cryay"
(1-61)
The emittance is independent of electron motion, according to Liouville's theorem. When the spatial distribution of the electron beam is small, the angular divergence becomes large, and vice versa. Moreover, there is a correlation between ex and ey, depending on the storage ring structure and the oscillatory motion of electron beam in orbit.
22
r
X
/
-Orbit ~
12.35 y
y -<
2.35o'x
950'x' L..J'
z
..._1
2.35~y'
Fig. 1-13. Schematic diagram showing the size and angular divergence of synchrotron radiation source. As mentioned previously, the photon flux, which is the photon number emitted per unit time, per unit angle in the horizontal plane, and unit band width, is defined by d3N
dtd OdA/~
[photons/sec/mrad(horiz.)/O.1% b.w./mA]
The flux is decided only by the electron energy, and is not related to the size and angular spread of the electron beam. Brightness, which is the flux represented for unit solid angle, i.e., the photon number per unit time, unit solid angle and unit band width, is defined by d3N [photons/sec/mrad2/0.1% b.w./mA] dtdl-2dA/~,. According to this definition, the angular divergence is given by convolution of the angular width of the electron beam with the intrinsic angular width of the radiation. High brightness would be required in many synchrotron radiation experiments, especially when one uses an aberration-free optical system. "Brilliance" is the brightness divided by the size of the radiation source, i.e., the photon number per unit time, unit solid angle, unit area,.and unit band width. The brilliance is defined by
23
d~ dtdl'2dSdA/A
[photons/sec/mrad2/mm2/0.1% b.w./mA]
where S represents the area of the radiation source, being related to the size and angular spread of the electron beam. When one needs a focused sharp radiation, high brilliance is necessary. The low electron beam emittance gives high brightness and high brilliance. 1.3. TYPICAL SYNCHROTRON RADIATION SOURCES The synchrotron radiation facility is typically composed of a linear accelerator, synchrotron, and storage ring, although several variations are possible. The major part of the facility is of course the storage ring. High energy electrons accelerated by the linear accelerator and synchrotron are injected and stored in the storage ring. In this section we discuss the characteristics of the source facility in general and describe typical facilities in operation and under construction.
1.3.1. General System of SR Source In the storage ring, as a radiation source, high energy electrons moving in a definite circular orbit are stored for more than several hours. The electrons are injected into the storage ring after being accelerated up to a final storage energy by the linear accelerator, and by the synchrotron in the case of full energy injection. Sometimes, especially in small or intermediate size SR facilities, the injection system is designed to be operated at a lower energy than the final storage energy, and there must be one or more radiofrequency cavities in the storage ring in order to accelerate electrons to full energy. When the electron energy is several 100 MeV, the SR spectra have a peak around soft X-ray to VUV range. And when the energy is several GeV, the spectral peak is in the X-ray range. Dipole magnets are arranged along the electron orbit to bend the electron beam. The magnetic field of the magnets is kept constant in the storage ring because the electron beam energy has to be kept constant. There are photon beam ports at the location of the dipole magnets so that the synchrotron radiation may be utilized. Between the dipole magnets on the straight beam line section there are quadrupole magnets, which provide magnetic fields with gradients to act as lenses for the electron optics system. The electron beam is maintained in a stable oscillation (betatron oscillation) around an equilibrium orbit by the lens action with the magnets. The electron circulating in the ring loses energy by emitting synchrotron radiation. This energy loss is again supplied by radiofrequency cavities, which are set up on a straight section of the ring, and an associated power supply. The radiofrequency may be selected so as to be an integer multiple of the electron orbital revolution frequency. The integer is called the harmonic number of the ring. With this scheme of radiofrequency acceleration, electrons in the ring can be grouped in bunches of the harmonic number. The radiation is, therefore, pulsed at definite
24 intervals. A fairly high total electron current is available since many discrete bunches of electrons are in the ring, although there is a limitation to the number of electrons stored in one bunch. If time-analysis experiments are intended, the electrons should be stored in a small number of bunches, with the interval of the radiation pulse being spread. When the electrons are assembled in a single bunch, the photon pulse interval is the maximum and equal to the time when electrons turn over the ring. The radiation is pulsed to the bunch width, which is typically about 10% of the radiofrequency period. The electron beam should be of small emittance so that we obtain a radiation source having high brilliance. The chamber in which the electrons circulate has to be maintained at an ultra-high vacuum. For the stored electron beam's decay time to be of the order of many hours, the average pressure must be in the 10-9 to 10-10 Torr range to minimize scattering of the stored electrons by the residual gas atoms. In the current SR facility design, insertion devices such as wigglers and undulators are widely employed in the storage ring. The insertion devices are other magnetic structures, which for many experiments are more effective sources of synchrotron radiation than the dipole bending magnets. The principles of the radiation emission from the devices (wiggler and undulator) are shown in Fig. 1-14a and 1-14b. Both wiggler and undulator magnets are inserted into the periodically deflected, although there is no net deflection or displacement of the beam from the equilibrium orbit.
2
(a)
2
(b) Fig. 1-14. Radiation from insertion devices; (a) Multi-pole wiggler and (b) undulator. Let us define a parameter K in order to characterize the synchrotron radiation emitted from the insertion devices, as follows.
25
eBoAu
K =
2nmc 2 = 0.934 Bdtesla] Au[Cm]
(1-62) (1-63)
Here, B o is the peak field and )~u the magnet period in cm. K is called "deflection parameter", being independent of the electron energy. A maximum angle with which an electron oscillates around the axis (z-axis) is given by K/),. On the other hand, instantaneously emitted photons are focused in a very small cone with angular width 1/?'. Thus, in the case of K >> 1 (Fig. 114a), the radiation can be observed in the z-axis only when electrons move near the top of their oscillating trajectories. This photon emission is evident via the wiggler (multi-pole wiggler). The radiation shows an increase in the critical energy, and a shift of the overall spectrum to higher energies compared to the dipole bending magnet radiation, although the spectral profiles are similar in both two magnets. If the wiggler is composed of N poles, the electrons oscillate N times within the wiggler and the radiation intensity (brightness) is increased to N times. In the case of K ~ 1 or K < 1 (Fig. 1-14b), the radiation is observed without intermission in the z-axis. This emission of radiation is evident in the undulator. The electric vector of the undulator radiation changes sinusoidally. Therefore, the radiation spectrum, which is described by its Fourier transformation, is quasi-monochromatic and a primary wave is prominent. The radiation, which is emitted at an angle 0 with respect to the z-axis, has its k-th order higher harmonics of the wavelength 2 k, given by ,~k
=
K2 2 k ~ ( 1 + - ~ + ~'202)
(1-64)
In the case of K << 1, the major component of the radiation is the primary wave, with wavelength/1,1 = Au/(27'2), on the z-axis (0= 0). As we will see later, an electron emits waves which add coherently. The radiation intensity varies with the square of N, and the spectral width A&/A is of the order of I/N, where N is the number of periods of the undulator. Electrons travel incoherently with respect to each other, and the photon intensity is proportional to the number of electrons. Undulators are extremely intense tunable radiation sources. 1.3.2. Typical Synchrotron Radiation Source Facilities
In response to a rapidly increasing demand a number of synchrotron radiation facilities have been built or are under construction or planning throughout the world. All the existing or planned SR facilities fall into three general classes: (i) small scale facilities with the electron energy less than 1 GeV and ec < 1 keV; (ii) intermediate scale facilities with the 1 GeV to 3 GeV electrons and 1 < ec < 10 keV; and (iii) large scale facilities with the electron energy higher than 3 GeV and e c > 10 keV. Generally speaking, the larger scale facilities can produce higher
26 energy photons or X-rays. However, of course, what decides the photon energies is the orbital radius as well as energy of the electrons. Even if the electron energy is low, higher energy photons are emitted with a high dipole-magnet field, which makes the electron orbital radius small. The first class facilities, which mainly produce radiation with wavelengths from soft X-rays to vacuum ultraviolet (VUV) radiations or longer, are useful for research in photo-electron spectroscopy (XPS), photochemistry, and photoabsorption in the soft X-ray to VUV range, and lithography and photo-etching. On the other hand, using the small scale facilities is not always beneficial for X-ray spectrochemical analysis, because X-rays with energy higher than 1 keV are usually employed as primary X-rays in the analysis. Intermediate and large scale facilities may be preferable for X-ray spectrochemical analysis. The large scale ones, especially, can produce X-rays with energy higher than 100 keV with high intensity, which make possible the excitation of K X-rays of even the heaviest element, uranium. In this Section, we describe, as examples, three of the typical facilities dedicated for SR studies, that is, the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory, USA, the Photon Factory (PF) at National Laboratory for High Energy Physics (KEK) at Tsukuba, Japan and the Super Photon Ring (SPring-8) at Harima Science Garden City, Japan (under construction).
National Synchrotron Light Source (NSLS) The NSLS was designed and built as a combined light source for VUV and X-rays. The overall layout of the facility is shown in Fig. 1-15. Electrons are accelerated in a linear accelerator to 100 MeV, and injected into a booster synchrotron and accelerated up to 700 MeV. Then the electron beam is transferred either to the 700 MeV VUV ring or to the 2.5 GeV X-ray storage ring. Table 1.1 Parameters of the VUV- and X-ray- storage tings in the National Synchrotron Light Source. Parameters
VUV Storage Ring
Normal operating energy Maximum operating current Lifetime Circumference Number of beam ports of dipoles Number of insertion devices Maximum length of insertion devices ~c (ec)
745 MeV 1.0 amp
B (p)
1.23 T (1.91 m)
51.0 m 17 2 2.5 m 25.3 A (486 eV)
X-ray Storage Ring 2.5 GeV 0.25 amp --20 hr 170.1 m 30 5 <4.5m 2.48/~ (5.0 keV) at 1.22 T 0.60 A (20.8 keV) at 5.0 T 1.22 T (6.875 m)
27 Table 1.1 (continued) X-ray Storage Ring
VUV Storage Ring
Parameters Damping times, lrx = Vy
17 msec
6 msec
~e Electron orbital period Lattice structure (Chasman-Green)
9 msec
3 msec
170.2 nsec separated function quad., doublets 8 bending 3.14, 1.20 0.023 52.88 MHz 4.5 x 10-4
567.7 nsec separated function quad., triplets 16 bending 9.15, 6.20 0.0065 52.88 MHz 8.2 x 10-4
Horiz. dumped emittance (e x )
1.5 • 10-7 m-rad
1 x 10-7 m-rad
Vert. dumped emittance (ey)
22.8 x 10-10 m-rad
1 x 10-9 m-rad
Source size, trh, trv
0.5 mm, > 0.006 mm
0.35 mm,0.15mm
Number of superperiods Nominal tunes, v x , Vy Momentum compaction RF frequency Natural energy spread (ixE / E)
The details of the facility design have been described by van Steenbergen and the NSLS staff [19]. Recent operating parameters of the VUV and X-ray storage ring are listed in Table 1.1 [20]. The basic ring structure consists of 8 bending dipole magnets in the VUV ring and of 16 in the X-ray ring, delivering continuum synchrotron radiation with e c = 486 eV (~.c = 25.3/~), and e c = 5.0 keV (~.c = 2.48 !k), respectively. There are several insertion devices; i.e., four undulators (U5U, U13TOK, X1 and X13) and three wigglers (X17, X21 and X25). (see Table 1.2) With the incorporation of the high field superconducting wigglers in the X-ray ring, the wavelengths can be extended to hard X-rays exceeding 100 keV. Table 1.2 Energy parameters for the insertion devices in NSLS (January 1991). Parameters Magnetic field - Bmax [T] Number of poles Periodic length
U5U
U13TOK
X1
X13
X17
0.46-0.01 0.72-0.05 0.31-0.03 0.31-0.03
[email protected] 2poles @2.6 55 44 69 20 7 7.5 10 8 8 17.4
X21/X25 1.1 27 12
- ~, [ c m ]
Wiggler characteristic energy- ec [keV] Energy range [eV] 11.3-70 - Undulator fund. Deflection parameter 3.2-0.08 range - K Gap range [cm] 3.4-12.0
0.265 2.2-50
22.2 for 5.2T poles 0.19-0.73 0.19-0.73 10-100
4.57 4-30
6.7-0.4
2.3-0.2
2.3-0.2
84
12.3
3.35-12.0
3.3-9.8
3.3-9.8
3.2
2.4-12
tO OO
X19
X-RAY
% U3 VUV X5 •
u7 -~=
Insertion Beamline
Device
Control
R o o m ~
Fig. 1-15. Overall layout of the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (by the courtesy of N. F. Gmuer).
29
10le E
..... VUV, 1:800mA " --XRAY, 1:250mA
.U~U
-=-_-.0.._.. . . . . . .-...
I0Is
~
X21,X25
'~ 1014
~I013
-
10~
u,ou
102
,,,
Ill!
\
.
.
.
.
.
.
.
105 104 Photon Energy [eV]
\ \
\
\
105
Fig. 1-16. Radiation spectra for NSLS bending magnet and insertion device (undulator and multipole wiggler) sources. The undulator curves are the envelopes of the first, third and fifth harmonics, 0.5 < K < 3. Figure 1-16 shows the radiation spectra (photon energy vs. flux curves) for the NSLS bending magnet and insertion device sources. Although the horizontal angular dependence of the bending magnet radiation is constant, output of the wiggler peaks on the axis, and falls to zero at ~ / y , where K is a deflection parameter given in Table 1.2 and y= Ering/mc 2 ; Ering = 745 MeV (VUV ring) and Ering = 2.5 GeV (X-ray ring). For the wigglers, the flux within one mrad (horizontal) centered on the axis is shown, even though most beam lines can collect more than one mrad horizontally. For the undulators, the central cone flux is plotted: the angular size of the cone depends on both the undulator and the electron beam parameters. Most beam lines can accept this entire cone. The undulator curves in Fig. 1-16 are the envelopes of the first, third and fifth harmonics, 0.5 < K < 3. In order to maintain precise control of the source locations and exit angles of the synchrotron radiation an elaborate electron beam deflection and correction system is incorporated in both storage tings. The VUV ring has 16 ports, and the X-ray ring 29 ports, of which some ports are split into two or more branches.
Photon Factory (PF) The PF is an X-ray storage ring fully dedicated to synchrotron radiation research. Figure 117 shows the layout of the facility [21 ]. A linear accelerator can accelerate both electrons and positrons up to 2.5 GeV. These are injected and stored in the storage ring. Since the full energy injection system is employed, there are two advantages in that the locations of the
30 sources of synchrotron radiation in the ring are controlled precisely and with good reproducibility, and the beam injection can be made in a shorter time. Table 1.3 Major parameters of the Photon Factory ring. Normal operating energy Maximum operating current Lifetime Circumference Bending radius Betatron tunes, horiz./vert. Emittance, horiz. vert. RF frequency
2.5 GeV (max., 3.0 GeV) 360 mA (e-), 350 mA (e+) 15 hr (300 mA), 30 hr (150 mA) 187 m 8.66 m 8.38 / 3.18 1.3 • 10 -7 m-rad 2.0 x 10-9 m-rad 500 MHz
0 ,
,
i
IA ~........,
2Bz
16C
~\11B
\
13m~"4 138z
Fig. 1-17. Layout of the Photon Factory at Tsukuba.
i
'
25m
31 The storage ring has an elliptical shape with diameters of 68 m and 50 m. The structure of the ring consists of 28 bending magnets, 58 quadrupole magnets and many small magnets for orbit corrections. Table 1.3 lists the main operation parameters of the PF facility. The radiation emitted from the electrons deflected by the bending magnets has a continuous energy spectrum with the critical energy of 4.11 keV (3.0 A). An electron loses energy of 400 keV per turn of the 187 m circumference, which means that a 300 mA electron beam loses 120 kW by emitting synchrotron radiation. The radiations from the bending magnets and the insertion devices are available at 24 ports, among which 15 ports are for the experiments and 3 ports are used for beam diagnosis. Table 1.4 Parameters for the insertion devices in PF. Line BL02
Type U
BL13
MPW/U
BL14
WS
BL16
MPW/U
2 u [cm]
N
Gmin [cm] Bmax [T] Kmax
hv [keV]
U0 [keV] 1.37 2.44
6.0
60
2.8
0.3 0.4
1.7 2.3
0.4 / 5.0 0.25 / 5.0
18.0
14
2.7
1.5
25.0
0.03 / 70
22.4
5.0
6.0
< 100
50.0 27.8
12.0
26
1.8
1.5
16.8
0.03/70 0.01 / 1.1
0.71 1.5 2.6 3.5
0.01 / 20
7.2
BL19
U
5.0 7.2 10.0 16.4
46 32 23 14
3.0 3.0 3.0 3.0
0.3 0.4 0.5 0.6
1.3 2.7 5.0 9.5
BL28
C
16.0
12
3.0 11.0
1.0 0.2
15.0 3.0
U, undulator: MPW/U, multipole wiggler and undulator: WS, wavelength shifter: C, circular polarization source: Au , magnet period: N, number of periods: Gmi n , minimum gap: B, magnetic field: K, K value: U0, radiation loss. The storage ring has two long straight sections (5 m long) and eight intermediate ones (3.5 3.75 m long). There are an electron injection apparatus, two sets of radiofrequency cavities and several insertion devices in the straight sections. Table 1.4 shows the major parameters of the insertion devices. An undulator made of SmCo 5 permanent magnets is installed in the long straight section (BL02). The undulator has 60 periods (6 cm each period) and the field is comparatively low (0.31 tesla maximum), producing high brilliance radiations with energy 0.4 to 5.0 keV. In BL16 is set a multi-pole wiggler (MPW), which has 26 periods with 12 cm length per period, producing the radiations between 0.03 and 70 keV with very high brilliance (almost 100 times that of the bending magnet radiations). The MPW is a complex of NdFe
32 permanent magnets (NEOMAX30H) and Permendur with the magnetic field variable from 1.5 to 0.05 tesla, by which one can select alternatively its operational mode,-- either the wiggler mode (fixed at 1.5 tesla) or the undulator mode (variable from 0.05 to 0.5 tesla). In BL14 a wiggler with super-conducting magnets of 6 tesla (maximum) is fitted to deflect electrons vertically to the orbital plane, which is useful for hard X-ray experiments. Other kinds of insertion devices are also available, which have been developed and installed recently.
Super Photon Ring (SPring-8) Up to the end of the 1980s more than twenty synchrotron radiation facilities have come into operation throughout the world, and studies using them have been made in many research fields. In due course, the need for high brilliance SR facilities was envisaged and new projects to construct the next generation SR facilities have started in Europe, the United States and Japan. The SPring-8, which is an 8 GeV SR source facility, is one of them. Construction started in 1990 and will be finished in 1997. Several requirements have been considered in designing the SPring-8 facility [22]. They are for: (i) a high brilliance source for both soft and hard X-ray radiations, (ii) a widely and easily tunable photon energy, (iii) a superior time structure of the photon beam (selective use of single- and multi-bunch beam), and (iv) a photon beam which has both a stable position and intensity. Insertion devices are to be the principal radiation sources for the next generation of SR sources. In particular, undulators with different spectral characteristics and polarization will be the most important radiation sources. In order to accommodate as many insertion devices as possible, the SPring-8 has a sufficient number of long, dispersion-free straight sections. A full energy injection method is adopted to make the beam position very stable. The injection system consists of a 1GeV linear accelerator as preinjector and a synchrotron to accelerate the electrons up to 8 GeV. Table 1.5 Major parameters of the SPring-8 storage ring. Energy Current (multi-bunch) Current (single bunch) Circumference Dipole magnet field Bending radius Number of cells
8 GeV 100 mA 5 mA 1435.95 m 0.665 T 40.098 m 48 (44 + 4)
Straight section length
6.4 m
Natural emittance Critical photon energy Tune, v x
6.89n nm-rad ze 28.32 keV Harmonic number 51.22 RF voltage 16.16 RF frequency
Vy
Synchrotron tune Momentum compaction Natural chromaticity Energy loss in the arc Energy spread Damping time, zx zz
0.0102 1.49 x 10 -4 - 13.17 - 43.32 9.04 MeV/rev 0.108% 8.473 msec 8.481 msec 4.242 msec 2436 17 MV 508.58 MHz
.~t I I 3
8
Experimental Hall
\,/ Linac
Storage Ring
-~
/~I~,~
"~~,.~~-~chro iron
Storage Ring Tunnel Long Beam Line
(30Ore)
r-------1
Long Beam Line
(Ikin)
"--"-'-'-'---~::z:~
Fig. 1-18. Plan view of the Super Photon Ring (SPring-8) at Harima science Garden City (by the courtesy of H. Kamitsubo).
34 The major parameters of the storage ring are summarized in Table 1.5 and a plan view is shown in Fig. 1-18. The circumference of the ring is 1436 m and is divided into 48 cells. Among them 44 are normal cells, each of which contains two 2.8 m bending magnets, ten quadrupoles, seven sextupoles and a 6.5 m dispersion-free straight section, whereas four are straight cells, which contain two 6.5 m dispersion-free straight sections, two 3-m long straight sections (in places of the bending magnets in the normal cells), and the same number of quadrupoles and sextupoles as in the normal cell. In addition to these, there are 12 steering magnets in each cell for closed orbital distortion (COD) correction and for dynamic feedback of the beam position movement. The chromaticity is corrected by three harmonic sextupoles which are located in the dispersion section between two bending magnets. The radiofrequency system (505.58 MHz) consists of four 1 MW klystrons and 32 cavities which are installed in 4 low-fi x straight sections each 6.5 m.long. The energy loss per turn due to SR emission in the bending magnets is 9.0 MeV, whereas the energy loss due to the insertion devices is estimated to be 3.2 MeV, and others due to the cavities and vacuum chambers are evaluated to be 0.5 MeV. In addition to this, an overvoltage is required for obtaining a long quantum lifetime. Calculations give the maximum peak voltage needed in the cavity as up to 17 MV. Table 1.6 Typical values brightness, flux and size of photon beam from SPring-8 Devices
Brightness Flux* [photons/s/ [photon/s/ mrad/0.1% b.w.] 0.1% b.w.]
Undulator 1
2 x 1019
1 x 1014
Undulator 2
2 x 1020
7 x 1014
Wiggler
2 • 1018
3 x 1014
Bending
2 x 1013
1 x 1013
* Flux;
Size [mm]
4x2
200 x 9
Au [cm]
L [m]
K
E0 [keV]
3.3
5
1
12.3
3.3
30
1
12.3
18
2
25
63.9
Undulator, photons through a hole ( ~ 0 - 64 mrad). Wiggler and Bending, photons / mrad.
Table 1.6 lists typical values of brightness and flux for the radiations from the undulators, wigglers and bending magnets, calculated assuming a stored electron current of 100 mA. From the bending magnets and insertion devices 23 and 38 beam lines are available, respectively. The average lengths of the beam lines are 80 m from the exit of the insertion devices or bending magnets to the photon beam dump at the end of the beam line. For studies requiring longer beam lines, 8 beam lines can be extended up to 300 m and three can be lengthened to 1000 m.
35 1.4. I N J E C T O R S
A synchrotron radiation source is composed of a storage ring, which accumulates and stores electrons (or positrons) over many hours, and attached beam lines for extracting the radiation to the experimental hall. The source of particles to a storage ring is called the "injector". One can classify injectors into two groups, depending on their energy relative to the operating energy of the storage ring. In many existing storage tings, as can be seen in Table 1.7, the injection energy is lower than the operating energy of the storage ring. In these cases, electrons must be accelerated to the operating energy by ramping the magnetic fields of the storage ring. In modern storage tings, however, the injector has the same energy as the operating energy. This scheme is called the full-energy injection. Table 1.7 List of typical synchrotron radiation facilities classified by their injector system Facility name
Storage ring energy [GeV]
(a)Synchrotron NSLS VUV (BNL) UVSOR (IMS) SRS (Daresbury) NSLS X (BNL) SPEAR (SSRL) INDUS-I (Indore) SRRC (Taiwan) ALS (LBL) APS (ANL) SP-8 (RIKEN/J AERI) (b) Linear accelerator SUPER-ACO(LURE) HESYRL (Hefei) Photon Factory(KEK) BEPC (Beijing) ELET1RA(Tfieste) PLS (Pohang) (c) Microtron MAX (Lund) ALADDIN(Wisconsin) op: in operation
0.75 0.8 2.0 2 . 6 - 2.8 4.0 0.45 1.3 1.9
energy [GeV] 0.75 0.6 0.6 0.75 2.3 0.45 1.3 1.5
Injector
rep. rate [Hz]
Status
0.66 2.5 10 0.66 30 2 10
op op op op op c c
7.0 8.0
7.0 8.0
2 1
1
c
0.8 0.88 2 . 5 - 3.0 2.8 2.0 2 . 0 - 2.5
0.8 0.2 2.5 1.4 2.0 2.0
12.5 1 25 50 10 10
op op op op c c
0.55 1.0
0.1 0.108
10 1.25
op op
c c
c: in construction
Needless to say, an injector is much more expensive for higher energies. However, the beam is generally subject to instabilities if it is injected at low energies and, in particular, is very sensitive to the operating parameters in the "low-emittance" storage tings which have been quite
36 common for several years in high-brightness synchrotron radiation sources. Table 1.7 shows that full-energy injection will be widely adopted in forthcoming storage rings. The accelerators which have been used as injectors for storage tings are synchrotrons, linear accelerators, and microtrons. Short descriptions of these accelerators will now be given.
1.4.1. Synchrotron The synchrotron is a circular magnetic accelerator which uses time-variable magnetic fields to bend and focus electrons. Since the magnetic field strength varies with the energy of the electrons, the orbit radius is always kept constant. Acceleration is achieved with the aid of radiofrequency (rf) accelerating cavities. In general, the rf frequency of a synchrotron must be changed with time in order for particles and fields to synchronize all the way. For an electron synchrotron, however, the time of revolution of the electrons around the ring does not depend on energy because of the constancy of their velocity, even at relatively low energies. Hence, a fixed rf frequency is adequate for electron synchrotrons. This simplifies their construction and operation, and makes it easy to operate them with a high repetition rate. As shown in Fig. 1-19, the basic components of a synchrotron are magnets for bending and focusing electrons, radiofrequency (rf) cavities for accelerating electrons, and specially designed pulsed magnets for injecting and extracting electrons. The electron beam passes through a hollow metal or ceramic pipe having a lateral size typically 5 cm x 10 cm. The pipe, which is called the vacuum chamber, is evacuated to a pressure of the order of 10-6 Torr.
extr
j l__lj ......
w IflJt~ULUI-
~
~
rf cavity
cross section
of magnet
Fig. 1-19. Schematic of a synchrotron. A small linear accelerator or microtron is used as the injector for a synchrotron. Electrons are injected into the synchrotron when its magnetic field is low (e.g. 1/10 to 1/20 of the maximum field strength), and are accelerated as the field strength increases. At the crest of the magnetic
37 field, electrons are extracted by means of pulsed magnets. This cycle is repeated at regular intervals. Usually, electron synchrotrons operate at a repetition rate between 1 Hz and 50 Hz.
(b)
Ca)
~t
--~t
Fig. 1-20. Magnetic field waveforms of synchrotron; (a) slow-cycling and (b) rapid-cycling. The synchrotrons are generally considered in two classes; the slow-cycling synchrotrons and the fast-cycling synchrotrons. The slow-cycling synchrotron, which operates at around 1 Hz, uses rectifying circuits for generating magnetic fields, and the field waveform is triangular (Fig. 1-20a). On the other hand, the rapid-cycling synchrotron repeats at a frequency of 10 to 50 Hz, and utilizes resonant circuits for generating magnetic fields. Hence, the field waveform is sinusoidal (Fig.l-20b). Generally speaking, a shorter injection time is better from the viewpoint of increasing the time available for the synchrotron radiation research. The injection time depends on the repetition rate and the number of particles which the injector can provide every cycle. Since there is a limit on the intensity which can be accelerated in a cycle, the rapid-cycling synchrotron gives us a shorter injection time. For technical simplicity and construction cost, however, the slowcycling synchrotron may be superior to the rapid-cycling synchrotron, since most technical components of the former are simpler. In the rapid-cycling synchrotron the magnet system needs an unusual high-power resonant circuit technique, while the thyristor rectifier used for the slow-cycling synchrotron is a popular component in power engineering. In rapid-cycling synchrotrons one also needs complicated corrugated or ceramic chambers to reduce eddy currents produced by the rapidly-changing magnetic field, and much higher power rf cavities. 1.4.2. Linear Accelerator
Radiofrequency linear accelerators have been the most popular injectors for synchrotrons, and can also be the direct injectors for storage rings. Figure 1-21 shows a simplified block diagram of a travelling-wave linear accelerator. The linear accelerator comprises an electron gun (a source of electrons), sections of microwave waveguides as the accelerating structure, and solenoid coils or quadrupole magnets for focusing electrons. The phase velocity of the microwave travelling down waveguide coincides with the velocity of electrons. Therefore, electrons which maintain the proper phase relationship with the microwave can be accelerated
38 continuously by the electric field pointing in the direction of motion. The most common accelerating structure is the disk-loaded waveguide working at a microwave frequency of about 3,000 MHz. Linear accelerators with energy lower than 20 MeV are widely used for medical applications and non-destructive inspection, and are commercially available. Their accelerating gradient per unit length of accelerator guide is typically 10 MeV/m, and a single microtron or klystron is used as a microwave power source. Linear accelerators of higher energies, which have been built for research applications, need many sections of accelerator guides and klystrons. For example, in the 2.5-GeV linear accelerator at the Photon Factory of KEK at Tsukuba, Japan, there are 160 sections of accelerator guides, each 2m long, with 40 klystrons used to energize them. A microwave power of 30 MW amplified in a klystron is split and fed into four accelerator guides. The KEK linear accelerator operates at a repetition rate of 50 Hz. The peak current of the accelerated beam is 50 mA in a pulse of 2 Its, in normal operation. The accelerating gradient per unit length of accelerator guide is 10 MeV/m. Accelerating structures with higher gradients, in the range of 30-50 MeV/m or even 100 MeV/m, are under development. Klystrons with powers of 50 to 100 MW are also becoming available.
Fig. 1-21. Travelling-wave linear accelerator; (a) accelerator guide and (b) disk-loaded waveguide. As mentioned before, linear accelerators have been used as injectors for synchrotrons. An energy of 20-30 MeV is appropriate for a synchrotron of an energy less than several hundred MeV, while an energy of 500 MeV to 1000 MeV will be necessary for a synchrotron of multiGeV. Linear accelerators have also been used for the direct injection to a storage ring. Most high energy linear accelerators in the multi-GeV range were built as injectors for high-energy electron-positron colliders for elementary particle physics, and some storage tings for synchrotron radiation rese~ch take advantage of these accelerators in parasitic use. However,
39 since high-energy linear accelerators are more expensive, synchrotrons are preferred as injectors for the direct injection into the storage ring, unless the beam is shared for other purposes. When positrons are stored in the storage ring a high-energy, high-intensity linear accelerator will be inevitable. Positrons can be produced by high-energy electrons bombarding a heavy metal target, such as tantalum. In the Photon Factory of KEK, a high-intensity linear accelerator of 230 MeV is used to produce positrons. Low energy positrons (around 5 MeV) produced at various angles and with various energies are focused using high-field magnetic solenoids, and accelerated to an energy of 250 MeV by another linear accelerator. The positron beam so produced is transferred to the main accelerator, in which the positron is accelerated to the final energy. Generally, the yield of positrons is roughly proportional to the beam power (i.e. the energy times the current) of the incident electron beam. At the Photon Factory the number of positrons accelerated to the final energy is around 0.1% of the number of the incident electrons. 1.4.3. Microtron The microtron is a circular accelerator in which a static magnetic field is used, and so the radius of curvature of the circular orbit grows with increasing energy. Acceleration is achieved by an rf accelerating cavity. As shown in Fig. 1-22a, each time the electron passes through the cavity it gains energy, and the orbit radius grows in discrete steps. If a proper relation holds between the energy and rf voltage, the orbits overlap at the position of the cavity.
(a)
i
agnet \rf cavity
e
f
f
(b)
Fig. 1-22. Schematic of microtron; (a) circular and (b) race-track. Small microtrons in an energy range of 10 to 50 MeV are commercially available, and are used in medical applications. The race-track design shown in Fig.l-22b has been applied to higher-energy microtrons of around 50 MeV. By this means, a cavity of multiple gaps can be inserted in a straight section between magnets, and a high accelerating energy per pass can be achieved. Although the intensity obtainable from microtrons is usually lower than from linear accelerators there are advantages in the beam quality, such as the excellent energy-spread and, more importantly, the cost is lower than that of linear accelerators.
40 Some synchrotron radiation sources have used a microtron of energy higher than 100 MeV as the injector to the storage ring. In addition to the examples listed in Table 1.7, a compact storage ring developed for micro-lithography has used a microtron of around 100 MeV. However, high-energy microtrons are not yet popular. 1.5. STORAGE RING
A storage ring is a circular ring, whose structure is essentially the same as a synchrotron's, and which keeps a beam of electrons (or positrons) circulating at relativistic velocities over many hours. It comprises magnets for bending and focusing the circulating beam, rf accelerating cavities for making up for energy lost as synchrotron radiation, and vacuum chambers for keeping an ultra-high vacuum along the particle trajectory. Figure 1-23 illustrates the principal functions of a storage ring. The magnetic system consists of bending magnets and focusing quadrupole magnets. Along the circular path in the bending magnets, synchrotron radiation is emitted in a tangential direction. Many beam lines for extracting the synchrotron radiation can be attached to normal bending magnets. Between the magnets there are straight sections which are free for installation of auxiliary components including rf accelerating cavities, pulsed magnets for injecting the beam, small magnets for controlling the orbit, diagnostic instruments, and vacuum pumps. In addition, insertion devices, which will be described later, are placed in the straight sections of the storage ring.
devlce
'~
l~bendlng magnet
7
/ from
L~
"~quadrupolemagnet \^
_
rf cavlty
_ ,./
Injector~l_l[__7,r_] ~
Fig. 1-23. Schematic of storage ring.
<synchrotron
I r~di-atio n
41
1.5.1. Storage Ring Parameters The principal parameters which characterize the performance of a storage ring will now be described.
Energy The energy of the storage ring is related to the spectrum of the synchrotron radiation. As described in the previous section, the spectral distribution of the synchrotron radiation is a function of the electron energy and the radius of curvature of the circular path. For normal bending magnets the critical wavelength of the radiation, Ac[A] = 18.6 / B[tesla] E2[GeV], as given by Eqn. (1-20). For high energy storage tings, the field strength of the bending magnet is usually chosen to be between 0.5 and 1 tesla, since these values are optima for economical and technical reasons. However, for compact storage rings which are designed for X-ray lithography, superconducting magnets with a field strength around 4 tesla have often been used. The advantages of taking high magnetic fields are that the size of the storage ring is reduced because of the small orbit radius, and that low electron energies are sufficient to give the radiation spectrum required for lithography. As described before, recent synchrotron radiation sources are based on the comprehensive use of insertion devices, particularly undulators. In this case, the required energy of the storage ring is determined by considerations different from those above, as will be described later.
Emittance While travelling in the storage rings, an electron makes a quasi-sinusoidal oscillation in the lateral direction owing to the focusing action provided by quadrupole magnets. This oscillation is called the "betatron oscillation"(Fig. 1-24). The electron with the design energy oscillates around the central orbit (the design orbit).
Fig. 1-24. Betatron oscillation.
42 Let s be the azimuthal coordinate along the orbit. The betatron oscillation is expressed by the following
y(s) = (e / fl
(S))I/2cos(O (S)+qbO)
(1-65)
where fl (s), which is called the betatron function, is a function of the azimuthal position, s. Here r (s) is the phase function which is given by $ (s)= ~(1/fl (s))ds, and $0 is an arbitrary phase: e is an arbitrary constant relating to the amplitude of oscillation and is called the "emittance". Equation (1-65) represents a pseudo-harmonic oscillation, whose amplitude and phase are modulated during motion, as shown in Fig. 1-24. If an electron has a slightly different energy from the design value, the orbit around which it oscillates will differ from the central orbit. This property is called dispersion. The equilibrium orbit for the off-energy electron is called the off-energy orbit. The quantity relating the orbit deviation to the energy is the dispersion function, usually designated as r/(s). The orbit deviation, Ay(s), for an electron of energy deviation AE/E is given by
Ay(s) = I"1 (s)AE/E
(1-66)
The betatron function fl (s) and the dispersion function r/(s) are uniquely determined if the magnetic configuration of the storage ring is given. Electron storage rings usually contain a periodic structure of magnets, and hence both betatron and dispersion functions have the same periodicity as the magnetic configuration. The amplitude and phase of the oscillation varies for the particles within the stored beam, which causes it to have a finite lateral size and angular spread. According to custom, we can define the emittance of the stored beam as the largest emittance within the beam. Roughly speaking, the emittance of the beam, which is defined independently in the horizontal and vertical direction, is given by the product of a lateral beam size and an angular spread. It is a measure of the transverse coherence of the electron beam and is a crucial parameter for determining the brightness of the synchrotron radiation. It is a unique property of the electron storage ring that the emittance does not depend on the injection condition, but is determined by the magnetic configuration (usually called the "lattice") and the electron energy. Owing to the emission of synchrotron radiation (or more precisely, owing to the compensation by rf cavities of the lost energy), the amplitude of the transverse oscillation is damped in an exponential manner with time, with a damping time which is given by the magnetic configuration of the storage ring and the electron energy. This effect is called the "radiation damping". However, due to the quantum nature of radiation and the randomness in the betatron oscillation phase at which a photon is emitted, the oscillation behaves like a Brownian motion, and its amplitude tends to grow. This effect is called the "quantum fluctuation". As a consequence of the existence of both effects, an equilibrium state is eventually reached. The distribution of the oscillation amplitude in the stored beam becomes
43 Gaussian, reflecting the probabilistic nature of the phenomenon. Hence we can define the r.m.s, beam size for any electron storage ring and, correspondingly, the r.m.s, emittance. The r.m.s, horizontal emittance, which is called the "natural emittance", has a particular meaning in the storage ring design, because it is determined just by the lattice structure and the electron energy. On the other hand, the vertical emittance is determined in practice from the horizontal emittance, through coupling between the horizontal and vertical oscillations, and it is usually a few percent of the horizontal emittance.
Bunch number and bunch length A storage ring applies the method of radiofrequency acceleration to make up for the radiation loss. If an electron is at a phase ~s, the energy gain balances the energy loss, and the electron will remain at this phase (Fig. 1-25). The phase ~s is called the equilibrium phase. An electron whose energy and phase deviate from the specified value is still stable if the deviations are small. In the stable condition the phase and energy oscillate around the equilibrium values. This represents "phase stability", and the oscillation is called the "synchrotron oscillation". According to the theory of phase stability, the stable area of the synchrotron oscillation is given by a separatrix which separates the stable and unstable areas of oscillation in the phase space made of phase and energy (Fig. 1-26). The area in which the phase stability holds is called the rf bucket. In consequence, electrons in a storage ring are bunched around a specified phase of sinusoidal rf voltage. The frequency of the applied voltage must be a multiple of the revolution frequency with which electrons circulate around the storage ring, in order for the electron and the rf field to synchronize. This ratio is called the harmonic number, and gives the maximum number of electron bunches which can be stored in the storage ring.
0 >
/0
~
) = Vsin
2~ft
~s ~_~2r~
radlatlon]oss energy galn
v
Urad Vsin ~s
Fig. 1-25. Sinusoidal rf waveform. The equilibrium phase is determined by the balance of radiation loss and energy gain.
44
(a)
0
2~
(b)
t
v
Fig. 1-26. (a) Rf bucket and (b) electron bunch. For the same reason as in the lateral distribution, the longitudinal distribution (in the moving direction) of electrons in a bunch also becomes Gaussian. In this case the r.m.s, length of the bunch is called the bunch length (usually expressed in units of sec). The rf frequency has been chosen between 100 and 500 MHz for technical reasons; hence the number of bunches will be several hundreds, or even more than a thousand in large storage rings. A typical value of the r.m.s, bunch length is 100 ps at the rf frequency of 500 MHz. If every rf bucket is filled with electrons, the radiation is observed at intervals of the rf period, and the radiation is effectively continuous in time from the experimenter's viewpoint. This is called the multi-bunch mode of operation. However, if a single rf bucket is filled, a train of very short pulses of radiation is observed at intervals of the revolution period. This is called the single-bunch mode of operation. Since the revolution time is of the order of gs in a typical high-energy storage ring, the single bunch operation is useful in studies of relaxation phenomena. Beam
current
The circulating beam contains a large number of electrons. The number of electrons (or intensity) is sometimes expressed by the circulating current (in units of mA). The radiation intensity is proportional to the stored current, so that higher currents are always desirable. However, the stored current is limited by instabilities of various kinds. Among them, the interaction of the beam with the metallic surroundings, and the ion-trapping effect, are dominant effects which limit the stored current. When the beam passes through conducting enclosures
45 such as rf cavities and vacuum chambers, the induced electromagnetic fields influence the beam and result in its instability. The ion-trapping effect is a phenomenon in which positive ions, produced through scattering of electrons by the residual gases, are trapped in the electron beam by electric attraction between electrons and positive ions. This can bring about complicated instabilities when the beam current increases. The ion-trapping effect can usually be observed as a growth in the lateral beam size. This leads to a reduction in brightness and brilliance of the synchrotron radiation. If the stored particles are positrons instead of electrons, however, no instabilities due to ion-trapping have been observed. This is the main advantage of selecting positrons as the stored particles. The stored current in most radiation sources ranges from 100 mA to 500 mA in the normal operation of multi-bunch mode. In the single-bunch mode of operation, however, the stored current is limited to several tens of mA because of the existence of single-bunch instabilities.
Beam lifetime The number of electrons stored in the ring decays exponentially with time. The time in which it decays to half is called the beam lifetime. The main cause of decay is the loss of electrons through scattering by residual gases in the vacuum chamber. The dominant processes are a loss of energy through the emission of Bremsstrahlung radiation and the Mr scattering with atomic electrons. If the energy lost in collision is greater than the energy acceptance of the stable area (rf bucket) of the synchrotron oscillation, the electron leaves the stability region of the synchrotron oscillation, and is eventually lost. Therefore, an electron storage ring requires a vacuum of the order of 10-10 Torr or lower in order to keep the beam alive over several hours. It is not necessarily an easy task to maintain this pressure while storing the beam, since the synchrotron radiation illuminates the wall of the vacuum chamber and this is the main cause of desorption of molecules and atoms. Therefore, the beam lifetime depends on the stored current. When the aperture of the vacuum chamber is extremely small, the Rutherford scattering, the scattering by atomic nuclei, causes a loss of circulating electrons. If the deflection angle of an electron exceeds a critical value, which is determined by the betatron function and the gap of the vacuum chamber, the scattered electron hits the wall of the vacuum chamber at the narrowest gap as it circulates in the storage ring. Since the probability of the Rutherford scattering increases at small angles, the rate of loss due to this scattering becomes significant when part of the ring vacuum chamber is extremely narrow. This is true when an insertion device such as an undulator with a narrow gap is placed in the storage ring. In low-energy storage rings the lifetime of the electron beam is affected by the Touschek effect. When the stored beam current is high, electrons in the same bunch collide with each other, and gain or lose the energy in the direction of movement. Some of them exceed the energy of acceptance of the rf bucket and are lost. A cure for this effect is to increase the applied rf voltage.
46 1.5.2. Low-Emittance Lattice
The importance of the low-emittance electron beam can be understood easily by thinking of the brightness or brilliance of the radiation. For high resolution spectroscopy radiation with a high brilliance is essential. Brilliance is a quantity conventionally defined as the number of photons emitted per unit of four-dimensional phase space, per unit bandwidth, per unit time. The size of the point source is given by the size of the electron beam, while the angular divergence of radiation is given by convolution of the angular divergence of the electron beam and the intrinsic angular divergence of the synchrotron radiation. As described in the previous sections, the intrinsic angular divergence of synchrotron radiation is very small; i.e. of the order of 1/y. Therefore, a low-emittance electron beam is essential in order to obtain the highbrilliance synchrotron radiation, particularly using undulators. As stated before, the horizontal emittance of the electron beam is determined by the betatron and dispersion functions and the electron energy. Hence the horizontal emittance depends on the type of lattice. Roughly speaking, in order to reduce the horizontal emittance the dispersion function should be as small as possible at the position of the bending magnets. The reason is easily understood by thinking of the nature of quantum fluctuations (Fig. 1-27). If the dispersion function is non-zero at the position of the quantum emission by an electron, the equilibrium orbit for the electron will change suddenly, due to the change of energy, and so the amplitude of oscillation changes, because the instantaneous position of the electron is not changed. Therefore, the growth of the amplitude of oscillation due to quantum emission depends on the dispersion function at the position of the quantum emission. The growth rate is small when the dispersion function is small. Since the horizontal emittance is determined by the balance of radiation damping and quantum fluctuation, small dispersion functions are essential to make the horizontal emittance small.
equilibrium orbit \
orbit
x~
jump
AY= ~l AE/E
/
\\
/
electron t r a j e c t o r y
X . /
| L-emission of a quantum i
Fig. 1-27. Illustration of the amplitude growth of the betatron oscillation owing to the emission of synchrotron radiation.
47 The most basic type of lattice which provides low emittances is the achromatic arc configuration (Fig. 1-28). The structure of this lattice consists of straight sections, for the installation of insertion devices, separated by an achromatic arc. The simplest achromatic arc is the double focusing achromat, commonly known as the Chasman-Green lattice, which uses a combination of two bending magnets with a quadrupole magnet placed at the middle. In this case, the dispersion function can be zero outside the bending magnets on both sides, as shown in Fig. 1-28, if an appropriate focusing strength is chosen for the central quadrupole magnet. The quadrupole doublets on both sides tailor the betatron functions.
achromatic arc
AV VA
QF QD
, J
I--'i , B
center of straight section
,
dispersion
0 ,i.._,V AIAV QF
I
B
QD QF
center of symmetry
Fig. 1-28. Chasman-Green configuration.
(a) Expanded Chasman-Green dispersion .f/
VAV ,_.-.,/~fA AV'i.--_, VAV AVA'~ 'AV VA'~ 'AVA
(b) Triple-bend achromat(TBA)
/,-- .... A\~, IlsperA 8iOn
AV I_.-"i 'A I I IV VLV 'V' 'V' 'AV B
B
B
Fig. 1-29. Typical low-emittance configurations.
48 There are many variations of the Chasman-Green lattice (Fig. 1-29). One can expand it by replacing the central quadrupole with several quadruploles. One can also make an achromatic arc with triple bending magnets and two focusing quadrupoles, called the triple bend achromat structure. Quadrupole doublets on both sides of the achromatic arc can be replaced by quadrupole triplets. In all cases, flexibility in the design of the optics and in the operation of storage tings can be improved with increasing numbers of quadrupole magnets, at the expense of cost and space. It should be noted that the horizontal emittance is strongly dependent on the angle of a bending magnet, or equivalently the number of bending magnets in the storage ring. As may be imagined from the nature of the dispersion function, the smaller the bending angle, the smaller is the dispersion function. According to calculations, the horizontal emittance is written in a general way as e = F.O.M. x E 2 /N 3
(1-67)
where E is the electron energy and N is the number of bending magnets. F . O . M . represents the figure-of-merit of a lattice with respect to emittance, which depends on the type of the lattice.
1.6. INSERTION DEVICES Insertion devices are new, powerful radiation sources. They are placed in straight sections of a storage ring and generate radiation with spectral properties different from those obtained using normal bending magnets. An insertion device comprises periodic magnets, whose polarity alternates periodically in the direction of motion of the electron beam. Therefore, the trajectory of electrons inside the insertion device wiggles like a section of sinusoidal curve. The effect of the magnetic field en the electron orbit is localized in the position of the insertion device, and the orbit is unperturbed in the rest of the ring. Insertion devices wb.ich have been used in operating synchrotron radiation sources are wavelength shifters, multi-pole wigglers and undulators. The wavelength shifter is sometimes just called the wiggler. Free-electron lasers (FEL) have seen unique progress in the past two decades. It has been conceived that they might bring us new technologies of generating very coherent, powerful radiation through the interaction of radiation with electrons passing through an undulator. The spectral range which FELs cover will be from the microwave to the vacuum ultraviolet region, or hopefully to the X-ray region. For the long-wavelength FELs electron beams from linear accelerators are used, while for the short-wavelength FELs electron storage rings are used. In any case, many proof-of-principle experiments have been done so far, and extensive developments are continuing. In the following section the basic properties of the insertion devices will be described.
49
1.6.1. Wavelength Shifter and Multi-Pole Wiggler The simplest insertion device is the "wavelength shifter". Consider three dipole magnets of alternating polarities shown in Fig. 1-30. If the field strength of each magnet is properly chosen, the electron trajectory makes a bump and the synchrotron radiation comes out of the magnets. The continuous nature of the spectrum of the synchrotron radiation from wavelength shifters is similar to that of the bending magnet radiation. Since the critical wavelength varies inversely with the magnetic field strength, however, wavelength shifters can generate shorter wavelengths than those achievable in normal bending magnets. To show an example, we consider the Photon Factory, at which the electron energy is 2.5 GeV. The field strength is 5 tesla for a superconducting wiggler magnet, while it is 0.96 tesla for the normal bending magnet. The corresponding critical wavelengths are 0.6A and 3.1A, respectively. It is clear that wavelength shifters with high magnetic fields provide practical means to obtain X-rays or even hard X-rays at moderate electron energies. A simple extension of the wavelength shifter concept is the "multi-pole wiggler". This is an array of many dipole magnets (the number of the magnets greater than three but not so many), and the radiation emitted in the forward direction is intensified by the number of magnetic periods. These magnets can be electro-magnets, either superconducting or normal ones, but are more often permanent magnets.
+
Fig. 1-30. Schematic of wavelength shifter.
1.6.2. Undulator When the number of periods increases, the synchrotron radiation exhibits particular features which are quite different from those of ordinary synchrotron radiation. As electrons pass through a periodic magnetic field, a quasi-monochromatic radiation, with a higher brightness than can be obtained from bending magnets, is generated by the interference effect. The devices using this concept are called "undulators". Let us consider a plane undulator, as shown in Fig. 1-31, with a magnetic field of the form By(s) = Bo cos(2zrS/&u)
(1-68)
50 where Zu is the period length of the undulator. If the field strength is weak, the electron follows a sinusoidal trajectory as
x(s) = (Zu/2Zr)(K/ y) cos(2nrS/Zu)
(1-69)
where K is the deflection parameter, K = eBo ,~,u/2a'mc2, as given by Eqn. (1-62). One sees from Eqn. (1-69) that the maximum deflection angle is a = K/y. In weak undulators the relationship K<
(1-70)
e
__4
[ Fig. 1-31. The principle of the plane undulator. If the electron is observed in the frame which moves, on average, with the electron passing through the undulator, the motion of the electron becomes a simple harmonic oscillation. Then dipole-radiation with a wavelength equal to the Lorentz-contracted undulator period, Z*=Zu/?'* is emitted. In the laboratory frame, the radiation is Doppler-shifted to a shorter wavelength which is given by ~1 =(,~,u/2T2)[ 1 + K2/2 + (719)2]
(1-71)
where 0 is the observation angle. By Lorentz transformation the angular distribution in the laboratory frame is confined to the narrow forward cone 0 < 1/),, as shown in Fig. 1-32a. The wavelength of the undu!ator radiation varies with the observation angle, but if one observes the
51 radiation at a specified angle one sees monochromatic radiation of wavelength A1. As Eqn. (171) shows, for the weak-field undulator the wavelength of the radiation is determined primarily by the magnetic periodicity, Au, and the electron energy, 7.
~
)
x
-
~
s-oscillation
in moving frame
--IIu
21/,t
In lab frame
Fig. 1-32. Distribution of undulator radiation with the acceleration vector lies, (a) in the x-axis, and (b) in the s-axis.
Fig. 1-33. Figure-eight shaped trajectory of electron in the moving frame. For K > 1 the motion of the electron in the moving frame is not a simple harmonic oscillation, but shows a figure-eight shape (Fig. 1-33). In this case, the oscillation is decomposed to a good approximation into the x-oscillation (Fig. 1-32a) and the s-oscillation (Fig. 1-32b). Since the oscillation is not simple harmonic, the radiation includes higher harmonic components in the spectrum, with peaks at ,~,k= ,~,1[ k (k = integer)
(1-72)
52 As Fig. 1-33 suggests, the spectrum of the radiation from the x-oscillation includes only odd harmonics, but that from the s-oscillation contains both even and odd harmonics. In the plane undulator the radiation is linearly polarized along the undulator axis, and elliptically polarized at non-zero angles. So far, we have assumed that the number of periods is quite large (N -.- oo). With a finite number of periods, however, the spectral line width of each line grows. Calculations show that the line width of the radiation from an N-period undulator is given by A~, / Ak =1 / Nk.
(1-73)
This is called the natural line width. It can also be shown that the peak power at the central wavelength is proportional to N 2. Therefore, the central brightness of the undulator is extremely high, about 104 times that from the bending magnet. However, the total power is proportional to N, since the line width is proportional to N-1. Considering that the maximum deflection angle, a, is small in undulators, the total power they radiate is relatively small.
Fig. 1-34. Plane undulator using permanent magnets: (a) basic design with permanent magnets only, and (b) hybrid design with soft iron as magnetic poles. Arrow indicates the direction of magnetization of permanent magnet. If one observes the radiation over a cone of finite angle, 0o, to the forward direction, the line width is broadened, as expected from Eqn. (1-71). A~ / ~ k .~ ~2 0o2 / (1 + K 2)
(1-74)
53 Comparing Eqns. (1-73) and (1-74), one can see that the line width becomes appreciable compared with the natural line width, unless the viewing angle is small enough; (1-75)
Oo <- 1 / ~'(Nk) 1/2
Equation (1-75) also shows the requirement on the angular spread of the electron beam in order to obtain a monochromatic radiation from an undulator. As described in Section 1.5.1., the electron beam has finite lateral size and angular spread which are determined by the betatron functions at the position of the undulator and by the emittances. Unless the angular spread of the electron beam is smaller than given in Eqn. (1-75) the spectral bandwidth becomes larger than the natural line width. Therefore, at the position of the undulators, the electron beam should be parallel to the undulator axis as far as possible. A focusing or diverging beam at undulators is not appropriate.
(a)
(b)
(c) "'d
"-&l
! I I I I I I ! I I ] I
illslIL..
! I I I I I I I I I 1
rV %
e
Fig. 1-35. (a) Helical undulator using double helix coils, (b) helical undulator using permanent magnets and (c) crossed field undulators.
54 A plane undulator is made of permanent magnets such as SmCo5 and Nd-Fe-B. An advantage is that small magnets can produce strong fields, and a short magnet period is possible compared with electro-magnets. The simplest configuration for undulator magnets is the socalled Halbach configuration, as is shown in Fig. 1-34a. The so-called hybrid configuration shown in Fig. 1-34b uses pole pieces made of soft iron as well as permanent magnets. Figure 1-35a shows a helical undulator which uses a double helix configuration (a pair of helical coils carrying electric currents in opposite directions). The direction of the magnetic field vector rotates along the undulator axis, and the electron follows a spiral orbit. The circularly polarized radiation is obtained on the axis of the undulator. The helical field can also be obtained with permanent magnets.- Figure 1-35b shows the magnet configuration of a helical undulator, in which permanent magnet pairs are placed alternately in horizontal and vertical directions. An example in Fig. 1-35c is a more elegant configuration which generates radiation with any polarization. Two plane undulators, one in the horizontal direction and the other in the vertical direction, are placed separately with a distance so as to keep the proper phase relation between two undulator radiations. In conclusion, undulators are powerful radiation sources, with high brightness, tunability of wavelength, and with the availability of various polarization states. The spectrum can be tuned by varying the magnetic field strength while keeping the magnetic structure and the electron energy constant. With permanent magnets the magnetic field is changed by varying the magnet gap (stronger fields can be obtained with narrower gaps).
1.6.3. Free Electron Laser
The possibility of operating a free electron laser was first demonstrated by the experiments made at Stanford in 1975 and 1977 [23, 24]. Madey and co-workers observed the stimulated emission of infrared radiation (~ = 10.6 l.tm) by relativistic electrons in a spatially periodic transverse magnetic field. Figure 1-36 shows the experimental setup. The periodic magnetic field, of strength 2.4 kG, was generated by a superconducting double helix with a 3.2 cm period and a length of 5.2 m. The electron beam and the infrared radiation were steered to pass through the magnet on the axis. A gain of 7% per pass was obtained at a current of 70 mA of 24 MeV electrons. The first operation of a free electron laser (FEL) was demonstrated by the same group, using the experimental apparatus shown in Fig. 1-37. In the experiment the injector was pulsed to emit a single bunch every 84.6 ns, equal to the round-trip transit time of the radiation between mirrors. Using the 43 MeV electron beam with a peak current of 2.6 A gave a peak power of 7 kW, which is greater by a factor of 108 than the spontaneous radiation, at a wavelength of 3.4 l.tm. The spontaneous radiation represents the usual radiation from the undulator. Since then, many FEL facilities have been built aiming at the wavelength range from microwave to infrared by using low-energy, high-current accelerators such as rf linear accelerators, and induction linear accelerators.
55
HELICAL MAGNET ( 3 . 2 crn PERIOD] -4-
/'-M,RaoR ~
. . . . .
.,, " . - .
"7. ~
~
24 MeV BUNCHED ELECTRON BEAM
..,-'"II~-- - ' -
M,RROR.--
_
.,.,,.,.,.....,
MOOULATEO 10.6~ RADIATION TO Cu:Ge DETECTOR ANO MONOCHROMATOR
MOLECTRON T-250 CO z LASER
Fig. 1-36. FEL experimental setup. The electron beam is magnetically deflected around the optical components on the axis of the helical magnet.
........
HELICAL MAGNET ( 3 . 2 cm PERIOD)
43 MeV BUNCHED .. . . . . . ELECTRON
=
Fig. 1-37. Schematic diagram of the free electron laser oscillator. The principle of operation of an FEL is that the electron loses (or gains) energy by interacting with the electromagnetic radiation in the periodic magnetic field, and that the radiation gains (or loses) the same amount of energy as that lost (or gained) by the electron. This process is a stimulated emission, which means a net amplification of the radiation. When the optical cavity is placed on each side beyond the undttlator one gets an FEL oscillator, if the gain in the radiation is greater than losses of radiation power in the optical cavity.
I
let
Pt~
~
let
s
Fig. 1-38. Principle of the interaction of electrons with the radiation field in the undulator.
56 In the following, the classical model developed by Colson [25] will be applied to describe the basic principle of operation of an FEL. Let us consider a plane undulator as shown in Fig. 131. The static undulator field wiggles the electron orbit, and gives the electron a transverse velocity fit. As a result, the energy of the electron changes by interaction with the transverse electric field E t of the radiation, by an amount proportional to fltEt . Whether the radiation gains or loses energy depends on the relation between the electron energy, 7, the wavelength of radiation, X, the undulator period, Xu, and the phase of the radiation, ~, at the time when the electron passes through the undulator. Consider the transit times for the electron and the electromagnetic radiation to traverse one period of the undulator. One obtains Xu / fl*c for the electron and Xu / c
for the radiation
where t * is the velocity with which the electron moves, on average, in the forward direction (see Eqn. (1-70)). The electron keeps a constant phase relationship relative to the electromagnetic radiation over many undulator wavelengths, if the difference of these transit times equals one period of the radiation (see Fig. 1-38), that is, when the following relationship holds: I c = Zu ( 1 / f l * c - 1/c )
(1-76)
Using Eqn. (1-70) for the average velocity one obtains the "resonance" condition: 7r 2 = (Au12A)( 1 + K212)
(1-77)
One should note that Eqn. (1-77) gives the same relationship as Eqn. (1-71), the frequency of the spontaneous radiation emitted on axis by the electron of an energy 7r from a plane undulator of a period Xu and a magnet parameter K.
Fig. 1-39. Phase space ($, 7) describing the motion of electrons interacting with the radiation.
57 As calculations show, the energy and phase motion of the electron in the field of the electromagnetic radiation is described by equations similar to those describing the synchrotron oscillation of electrons in a storage ring, but without radiation loss. Hence, the electron trajectories are represented by the phase space (~,),), which is shown in Fig. 1-39. If the electron is at a fixed point, at which the energy equals the resonance value ~'r and the phase relative to the radiation lies on 7r, the electron stays at equilibrium all the time, and there is no net effect on the electromagnetic radiation. However, if the electron lies at any point in the phase space other than the fixed point, it will move in the phase space along a corresponding trajectory, and the electron will change in energy. This produces a gain or loss in intensity of the electromagnetic radiation. Consider a case of a more realistic energy-phase distribution function for the electron beam. In most FELs one can assume that the electron beam is continuous in the phase direction, and that the energy distribution is narrow. If the electron energy is at resonance, some of the electrons gain energy, some of them lose it, and the amounts of energy gain and loss are balanced, so there is no net effect on the electromagnetic radiation. Calculations show, however, that if the electron energy is above (or below) the resonance value, the electron beam as a whole loses (or gains) energy, and the electromagnetic radiation is intensified (or faded). The energy gain, G, in the electromagnetic field intensity during one traversal of the undulator is calculated [26] for a helical undulator as: G = -32 x 21/2 7r2 ro ~ u 1/2 ,~,3/2peN 3 {K2[(1 +K2) 3/2 }f ( x )
(1-78)
Here ro is the classical electron radius (2.8 x 10-13 cm), Pe the electron density, and it is assumed that the transverse cross section of the electron beam is equal to that of the electromagnetic radiation. The functionf(x) is called the gain function, which is given by f ( x ) = ( l [ x 3 ) { c o s x - 1 + (x/2)sinx}
(1-79)
x = 47rN(?'o
(1-80)
and -
~)1~
and is plotted in Fig. 1-40. When the electrons interact with the radiation field, both the energy distribution and the phase distribution change. When observed at the undulator exit, the phase distribution of the electrons is modulated at the radiation wavelength, and the energy distribution is broadened. If the energy spread is larger than 1/2N (the line width of the spontaneous radiation of an ideal FEL) during passage in the undulator, the energy conversion rate is strongly reduced, and the gain reaches saturation.
58
~
f(x)
0.08 O.06 0.04
0.02 -I0
t
-5
I
I0 -0.02 -0.04
-0.06 -0.08
Fig. 1-40. The gain functionf(x). These energy-phase behaviors have brought us an idea of the "optical klystron". The idea of prebunching the beam was proposed by Vinokurov and Skrinsky in 1977 as a way to increase the gain over the uniform undulator [27]. A merit of prebunching can be easily understood by remembering that, if N electrons are bunched within an extremely small time scale (equal to, or smaller than, one period of the electromagnetic radiation), the radiation intensity is proportional to N 2 instead of the ordinary factor N. The basic scheme of the optical klystron is shown in Fig. 1-41. It comprises two undulator magnets separated by a specially designed dispersion section (a simple drift-space is adequate in principle, but it takes a much longer space to obtain an adequate bunching).
k/V /k kjV Fig. 1-41. Principle of the optical klystron. The electron is energy-modulated in the first undulator and bunched during passage through the bunching section between two undulators.
59 In the first magnet system, the electrons are energy-modulated as well as bunched. During passage through the dispersion section, the electrons are bunched at intervals of the radiation wavelength. The second undulator is for transferring the energy to the radiation field. The gain enhancement by using an optical klystron has been demonstrated experimentally to be a factor of 5to 10. For shorter-wavelength FELs electron storage rings have been conceived superior to linear accelerators, since storage rings can provide a beam with a high peak current (higher than 100 A) and a good emittance, and hence a high electron density, and good energy resolution (less than 0.1%). In the storage-ring FELs, however, the energy-spread of the beam grows, due to the interaction with the electromagnetic radiation, because the same bunch of electrons traverses the FEL many times. The energy-spread of the beam reaches an equilibrium, by balance with the radiation damping caused by the synchrotron radiation emission all around the ring. When the energy spread becomes comparable to the natural line width, 1/2N, the effective gain decreases and the laser power saturates. The first operation of a storage-ring free-electron laser was demonstrated at A =6500/~ on the ACO storage ring at Orsay (France) in 1983 [28]. Since then, several experiments have been made, mainly in the visible region, and one experiment was made in the ultraviolet region at Novosibirsk in 1988 [29]. As seen in Eqn. (1-78), the gain varies as the 3/2-power of the wavelength of the electromagnetic radiation, so a beam of extremely good emittance and high current is needed for obtaining a sufficient gain at shorter wavelengths. New storage ring projects dedicated to the FEL are now in progress. Storage rings with a small emittance, of the order of several nm-rad, have been conceived. 1.7. BEAM LINE
The synchrotron radiations generated in the bending magnets or insertion devices are taken from the ports of the ring and delivered to the experimental station through a beam line. The beam line is a light-path connecting the storage ring and the experimental station, and performs the function to extract or cut off the photon beam. Various kinds of optical instruments, such as reflection mirrors and monochromators, are set up in the beam line according to the characteristics of the synchrotron radiation to be used and the purpose of the experiment. Since one beam line can accept sufficient radiation (about 30 mrad) to serve several simultaneous experiments, the "main beam line" usually has several branch beam lines downstream. 1.7.1. Main Beam Line
Figure 1-42 gives an example of the layout of the front end of the main beam line in the Photon Factory (KEK) [21]. In order to shield high energy ),-rays and neutrons from the storage ring, a concrete shield wall 40 - 90 cm thick separates the ring from the experimental
Z;
o
5b" "&.
UMATIC
9
.
ABSORBER
Fig. 1-42. Layout of the front end of main beam line.
61 area. The front end of main beam line functions to protect the ultra-high vacuum of the storage ring and to deliver synchrotron radiation to the branch beam lines. The vacuum upstream of the main beam line is to be kept as low as that of the storage ring (10--10 Torr). This is attained by use of four triode ion pumps and two titanium sublimation pumps. As shown in Fig. 1-42, the line is typically composed, moving downstream along the light path, of a manual valve, a water-cooled absorber, isolation pneumatic valves, fast-closing valves, mask slits, an acoustic delay line, beam shutters and a large pneumatic valve. The manual valve is used to cut off the vacuum between the ring and beam line in the event of maintenance of the line. The light absorber is made of oxygen-free copper plate about 20 mm thick, cooled with flowing water, and serves to protect the beam shutter and valves from overheating by the synchrotron radiation. The mask slit is used to define the size of the photon beam delivered. The fast-closing valve, which is driven by compressed air or springs, is to isolate the vacuum from the storage ring, and acts within about 15 msec so that any accidental venting in the branch beam line, caused by equipment failure or experimenter error will not have an adverse effect on the storage ring. The acoustic delay line (ADL) is also used to provide a 200 - 300 msec delay in the arrival time of a sonic wave that could be initiated by an abrupt vacuum failure. The ADL in the Photon Factory is a stainless steel tube 31 cm in diameter and 200 cm in length, loaded with an array of nine conical diaphragms each having a rectangular aperture. To ensure that the valves close in the event of an accident, and that they can only be opened under proper vacuum conditions, a control system is essential. This system permits the storage ring operators or the experimenters to open gate valves only when the pressure measured by a vacuum gauge is below a preset level. The beam shutter, made of a copper and stainless steel block is to ensure that hard X-rays or T-rays do not escape downstream.
1.7.2. Branch Beam Line The main beam lines are divided into several branch beam lines. The branch beam lines are classified into two categories; VUV beam lines for VUV radiations and soft X-rays, and X-ray beam lines for X-rays and hard X-rays. The VUV beam lines are directly connected to the storage ring through the main beam line, which means that the beam lines must be kept at ultrahigh vacuum with an oil-free specification and that optical instruments in the lines, such as reflection mirrors and diffraction gratings are maintained totally clean. In designing the optical system special care is necessary to minimize deterioration of the optical devices by photon beam exposure and to remove beam-induced heat by means of flowing water or liquid metal coolants. The vacuum system of X-ray beam lines is usually separated from the main beam lines by a beryllium window, through which X-rays can pass to the experimental station. Even in the Xray beam lines the vacuum should be maintained below 10-7 torr so that reflection mirrors and other optical devices are always clean. Some X-ray beam lines are directly connected to the storage ring without a beryllium window, just like VUV beam lines.
TMP
.
.
.
.
.
.
.
.
.
.
l
~
!
M
_
!
r
T
~
!
~
~ ~
~
"
i11111
-
f
~
~
-
~
l
~
~>
TO CONSTANT DEVIATION 9.
LARGE /,MONITORMIRRORAI~U~F..R vAF~L,UI~TIC / ,,..B~..ANCHBEAM LINE LIGHT ABSORBER .... / /\ M!RRORADJUSTERS FOR G R A S ~ R \ / / \ ~ A___NOCONSTANT DEVIATION
I
SUPPORT STRUCTURE
BRANCH BEAM LINE LIGHT ABSORBER /~ TO SEYA-NAMIOI'r ~ ~ MIRROR M AD,,IUSTERSFOR SE_YA,NAMIOKA/ PNEUMATIC VALVE
\ X,Y,Z
ADJUSTER
Fig. 1-43. Layout of the beam-splitting section of VUV beam line (BL11 of PF).
63 Figure 1-43 shows the beam-splitting section of the VUV beam line (BL11 of the Photon Factory), located just outside the shielding wall. The front end is split into four beam lines. These are equipped with a Seya-Namioka monochromator, a grasshopper monochromator, a toroidal grating monochromator (TGM) and a double-crystal monochromator. Chemicalvapor-deposited silicon carbide (CVD-SiC) plane mirrors are installed in the mirror chambers. In the downstream part of the beam-splitting section are situated the beam transport tube, vacuum valves, optical system (monochromator, mirror, and so on), slits, pumps, vacuum gauges and the beam position-monitoring system. At the back end of the X-ray beam lines is set a beryllium window for extracting a beam to the atmosphere. The window and the experimental apparatus are accommodated in the shielded room which is protected from hard Xrays and ),-rays. At the back end of the VUV beam line are located a specimen chamber and other experimental apparatus, directly connected to the storage ring. BL-10 (X-RAY)
DOUBLE CRYSTAL MONOCHROMATOR (Si 111!
SL,r, I
/
EXPERIMENTAL HUTCH
TOROIDAL MIRROR
c
|
,,,P"~' I ' J EXAFS ~ ' / / z ~ A SLIT \ / ~.A - - DOUBLE CRYSTAL FLAT SINGLE " ~ MONOCHROMATOR MONOCHROMATOR ~ (Si 311) (graphite / Si 111) " FOUR CIRCLE DIFFRACTOMETOR
5
BL-I I (VUV)
~
C. lm SEYA-NAMIOKA
B -,o,,~_.,,, MASK",..,,IVMI~RROR
10m
GRASSHOPPER D. 2m CONSTANT DEVIATION
r
-"
~"
~/A///////~,//~y,7`~/////////////////////////////////////////////////////////////////////////////`//. ~)
5
l~)m
Fig. 1-44. Layout of typical X-ray beam line and VUV beam line. The beam lines: BL10 (X-ray) and BL11 (VUV) of PF are shown. Figure 1-44 gives examples of the layout of an X-ray beam line (BL10) and VUV beam line (BL11), showing typical arrangements of the optical system and experimental station. The characteristics for these branch beam lines are described in Table 1.8 [21]. For BL10A a pyrolytic graphite is used as a dispersive crystal monochromator for obtaining a large integrated
64 intensity. For BL10C, a tuneable double-crystal monochromator is housed upstream, and a mirror downstream (See Chapter 6, Section 6.2 for the detail of BL10C). In order to have a fixed exit beam position in this monochromator either the first or the second crystal is translated along the incoming beam direction while rotating both crystals. The two crystals are driven independently by a microcomputer controlled unit. Table 1.8a Optics of the branch beam line BL10 in PF. Branch beam line
Horizontal Monochromator acceptance [mrad]
Mirror
Energy resolution (AE / E)
Energy range [keV]
BL10A
1
graphite germanium
none
5 x 10-3 5 x 10-4
6 - 24
BL10B
2
channel cut crystal, Si 311
none
1 x 10 -4
BL10C
4
double crystal Si 1:1 focusing 2 - 3 x 10-4 fixed beam height toroidal Pt-coated
4 - 10
4 - 10
Table 1.8b Optics of the branch beam line BL11 in PF. Branch beam line
Horizontal Pre-mirror acceptance [mrad]
Monochromator
Energy resolution (~,/A~,)
Energy range
[AI
BLllA
1.3
M0:88 ~ plane MI: 88~ spherical
Grasshopper Mark VII 2400 lhnm
(A~, =0.02/~)
10 - 145
BLllB
4.0
89 ~ bent cylinder
double crystal fixed beam height
> 2000
2 . 8 - 15
BLllC
4.8
77.5 ~ plane 42.5 ~ concave
1 m Seya-Namioka
20003000
4003500
BLllD
2.6
86 ~ cylinder 86 ~ plane
2 m constant deviation monochromator
10002000
60 - 600
65 BL-2 (SOFT X-RAY UNDULATOR)
LINEARTRANSLATOR
10-m GRAZING INCIDENCE
CONDENSERFRESNEL).--1"'"~ p,N~G BEAM BEAMLINE FAST CLOSING / ~ ~ SHUTTER DIAPHRAGM VALVE " r~ UR y i
P
A 9
i,
~
/===~
9
DEFLECTION MIRROR
9
=
a
~
9 '.
~ ~
- ~
9
9
i I 'l 't ='--
MONOCHROM.
~ ~ : : ] ~
. . . . . / . . . . .~-.... - ~ \ ~ ~~U~/~\GRATING
.~~ EXIT SLIT ~X!T~,S..I'-I
Iv nTrnllTlv v i' iJ,iJiJiiJAi
SECON6CRYSTAL I
HUTCH | ROTATABLE DOUBLECRYSTAL 7-RAY "PHOTODIODE MONOCHROMATOR STOPPER
SLE
STRAIGHT BRANCH
Fig. 1-45. Schematic diagram showing the beam lines for soft X-rays from undulator (BL2 of PF). Figure 1-45 gives an example of the beam lines for soft X-rays from an undulator (BL2), schematically showing an arrangement of beam-line components [30]. Two branch beam lines are installed, one utilizing the radiation deflected by a mirror, and the other being set on the line along the undulator. The two beam lines are used in a time-sharing mode, because the beam from the undulator is of extremely high directivity and small size, and consequently one cannot use both lines simultaneously. 1.7.3.
Beryllium
Window
A beryllium window is used to separate X-ray experimental areas from the ring vacuum. The windows must be thin, to ensure high X-ray transmittance, but thick enough to ensure mechanical strength and thermal conductivity. Figure 1-46 shows the window assembly for an X-ray beam employed in the Photon Factory. The beryllium foils 0.2 mm thick are set up at both ends of the assembly. In front of the upstream window, A graphite foil 20 l.tm thick is fixed to a copper frame in front of the upstream beryllium window in order to decrease the thermal load imposed by synchrotron radiation. This upstream window faces an ultra-high vacuum environment. The cross-shaped pipe is evacuated to 10-6 Tort with an ion pump. The beam transport ducts from the downstream window to the experimental apparatus are f'flled with purified helium at 760 Torr, because air causes too much X-ray beam attenuation and scattering. The downstream window, therefore, has to bear the helium pressure, but is only exposed to small thermal loads because of the absorption of low-energy radiation components by the upstream window. A major problem in utilizing thin foils lies in joining the beryllium to other materials so that it can be made part of the vacuum system. Several techniques are being employed, such as brazing or soldering the beryllium to copper or aluminum in an inert atmosphere, diffusion bonding to copper or Monel, glass-frit bonding to Monel, electron beam bonding to aluminum, or mechanical sealing with indium wire as a gasket.
66 0 i
5 i
. . . .
. . . .
loom i
HELIUM GAS
i
?'-~--L_
t
LL
i I
.J-"" ~ 1 [
LI
il S~'NCH~Or~ON
v=~uuM~L*~E
i
_
I
ION PUMP
Fig. 1-46. Schematic diagram of double beryllium window assembly.
1.8. OPTICAL SYSTEM Much effort is being devoted to the development of experimental equipment for synchrotron radiation research. Instrumentations that have been developed to meet the specific requirements of particular researches are described in the following chapters of this book. In this section we give an introduction and a general survey of the instn~mentation. The principal instruments are mirrors, monochromators and detectors. They are usually designed as components of vacuum or ultra-high vacuum systems, because they are accommodated in the vacuum chamber. 1.8.1. Mirrors Mirrors have the functions of deflection, focussing and filtration for synchrotron radiations. With beam splitting mirrors part of a single radiation beam can be deflected so that several experimental stations can share a single beam with space between them for equipment. Curved (cylindrical or toroidal) mirrors are used to obtain an image of the source point at some distant location. Filtration by mirrors is a function which makes a sharp cut-off in reflectivity above a certain photon energy. They can also act as low-pass filters, absorbing unwanted X-rays in VUV beam lines and achieving control over harmonics in VUV and X-ray lines. The reflectivity of a mirror depends on the photon energy, the angle of incidence, the mirror's surface material, and its smoothness. Figure 1-47 shows an example of the reflectivity as a function of the grazing angle of incidence for various photon energies [31 ]. The cut-off energy varies inversely with the grazing angle. Consequently harmonics can be controlled by varying the grazing angle of beam incidence.
67 1.0
------T~ "X " " ~
~
~+
"
"5--,
~w 05"'~
i|
---'---"
'
A
I
,
tt.
, 0.1
0
/. 8 12 GRAZING ANGLE e (DEGREES)
Fig. 1-47. The measured reflectivity of Au and C as a function of the grazing angle of incidence for various photon energies. Various materials are used as mirror substrates, including Be, Cu, SiC, fused SiO 2, zerodur, electroless nickel phosphorus (Kanigen), and float glass. The most frequently used coatings are Au and Pt, although uncoated mirrors are also used. The surface smoothness achievable varies for the various materials. In the case of fused SiO 2 and SiC, a micro-roughness lower than 5/~ r.m.s, has been attained by recent polishing techniques [32]. It becomes harder to achieve the surface smoothness in larger and more complex curved mirrors. It is reported that the autocovariance distribution of the surface micro-roughness becomes more important in X-ray ranges than does the micro-roughness height [33]. For mirrors in rather low energy storage ring beam lines, where thermal loading is not serious, fused SiO 2 is being employed. Even in high energy storage tings fused SiO 2 can sometimes be used for grazing incidence mirrors with an angle higher than about 88 ~, because much of the beam power is reflected and the absorbed power is distributed over a large area. However, surface deterioration is inevitable after long term use. When thermal loading is severe, as in the direct X-ray beam lines of multi-GeV storage tings, SiC or Kanigen-coated copper or aluminum, can be used. The former is the superior material, with a low thermal expansion coefficient and high thermal conductivity. The latter can be polished easily but, owing to its high thermal expansion coefficient, the surface will deform by thermal loading. The mirror must be cooled by flowing water or liquid metal in these applications. Segmented
68 mirrors are sometimes used where length of the mirror is especially required, as with in the case of an extreme grazing angle of incidence. Curved mirrors can be used to image the electron- or photon-beam source point at VUV and X-ray wavelengths. Magnification by the mirror system depends on the curvatures of the mirror surface, the grazing angle of incidence, and the mirror's location in the beam line. Demagnifying optics are used to obtain a high flux-density on samples as small as 100 l.tm in diameter. Magnifying optics are used to illuminate several square centimeter areas, as is required for pattern replication by soft X-ray lithography. 1.8.2.
Monochromators
Since most synchrotron radiation experiments are carded out by choosing a particular wavelength from the continuum and often scan over a range of wavelengths, a tuneable monochromator is indispensable. Many specialized monochromator systems have been developed for use in the VUV, soft X-ray, and hard X-ray regions of the spectrum. At synchrotron radiation facilities the light source, the beam line with the relevant optical components, the monochromator, and the experimental set-up have to be considered as a whole in order to maximize the flux of monochromatized photons onto the sample.
VUV
monochromators
VUV monoehromators fall into two classes, namely normal incidence monochromators (NIM) for the spectral range from about 6 eV to 50 eV photon energies, and grazing incidence monochromators (GIM) for the range about 30 eV to 600 eV. Three types of NIM are commonly used with synchrotron radiation sources, i.e., the standard (McPherson) NIM, the Seya-Namioka monochromator, and the modified Wadsworth monochromator, which are shown schematically in Figs. 1-48a, 1-48b, and 1-48c. They are all conventional mounts of concave spherical gratings with focusing properties. The McPherson NIM is a monochromator operating in a mode close to the Rowland, with one optical c o m p o n e n t , - a grating. In order to vary the wavelength the grating can be rotated and, to maintain focusing, can be translated at the same time. This system has the capability of high resolution with its ultimate values of the grating's constant and the radius of curvature. The Seya-Namioka monochromator has the simplest scanning mechanism, i.e., a single rotation of the grating about an axis through its center. Because of the fairly large angle of incidence this monochromator has abominable astigmatism, if a point light source is used near the entrance slit. However this drawback can be corrected by using, for example, an additional focusing mirror. The Wadsworth monochromator exploits one of the particular properties of synchrotron r a d i a t i o n - small d i v e r g e n c e - because it requires the light source to be at infinity for optimum performance. Wavelength scanning is achieved by simple rotation of the grating.
69
----,,
FG
I
FM i
(a) Mc Pherson Normal Incidence
(b) Seya-Namioka
(c) ModifiedWadsworth Fig. 1-48. Schematic diagrams of various normal incidence monochromators for use with synchrotron radiation. FG, focusing grating: FM, focusing mirror: PM, plane mirror. Various types of grazing incidence monochromators have been used in conjunction with synchrotron radiation. As typical examples of GIM, the plane grating monochromator and Rowland-type monochromator are shown in Figs. 1-49 and 1-50, respectively. Figure 1-49a shows the simplest instrument, with only one optical surface, a plane grating. Wavelength change is achieved by means of rotating a Soller slit system around an axis parallel to the grating grooves. Only moderate resolution is attained with this mounting. The instrument shown in Fig. 1-49b uses a plane grating and a spherical mirror. The grating is rotated by small angles so that the sum of the entrance and exit angles is fixed. The exit beam is spatially fixed, which allows its use in complex experimental facilities. Suppression of higher orders is made in only a limited wavelength range, by suitable choice of incident angle at the grating and the following mirror. Sometimes a plane mirror is used as a pre-mirror, so as always to illuminate the center of the grating in the arrangement shown in Fig. 1-49b. Figure 1-50 schematically shows the two typical grazing incidence monochromators based on the Rowland circle mounting. The entrance slit, grating, and exit slit are all located on the Rowland circle to minimize aberrations. This mounting can provide the best resolution for grazing incident monochromators. Figure 1-50a shows the simplest arrangement of a Rowland mounting. For absorption type experiments with the samples in front of the spectrometer, the
70 Rowland spectrograph is extremely useful, because the photographic plate or position-sensitive detectors allow the whole spectrum to be taken at a single exposure. In the instrument shown in Fig. 1-50b the entrance and exit slits are fixed while the grating slides along the Rowland circle. The directions of incoming and outgoing beams can be changed by a rotating mirror-slit combination. There are also several other variations of the Rowland mountings, with different arrangement of mirrors, gratings and slits.
PG
(a) PG
(b)
FM
Fig. 1-49. Two types of plane grating monochromators.
FM
(a)
.. FM
G
(b) Fig. 1-50. Rowland type monochromators. G is a concave grating.
71
X.ray monochromators Crystal diffraction can be used to monochromatize synchrotron radiation (SR). If d is the distance between atomic planes, Amax = 2d is the maximum usable wavelength. Table 1.9 lists values of d for several useful materials for this purpose. The inorganic crystals are generally quite resistive to the primary synchrotron radiation (SR) beam. High resolution can be achieved easily if the angular divergence of the incoming radiation is small. Table 1.9 The values of lattice constants in X.U. (~ 10-3/~). The geometrical distance between atomic planes, d, is given. Crystal
d [X.U.]
Crystal
silicon (220) germanium (220) quartz (1120) NaC1 (100) calcite (100) silicon (111)
1920 1997 2451 2814 3029 3135
germanium (111) quartz (1011) quartz (1010) gypsum (010) lead stearate cerotic acid
m
d [X.U.] 3262 3336 4246 7585 50300 72500
w
*~Si
r 0.6
9 , P.G.
o
LiF
9, o , m
O
>
'~
o.r
9m
9
9 #m
mm
m
[]
m
II
r'r" 0.2 mm mm
-20
-15
-10
-5
0
5 "
Angle (min.)
10
1'5
20
Fig. 1-51. Rocking curves measured with double crystal (+,-) arrangement, for Si(111) - Si(111), Si(111) - PG(0002) and LiF(200) - LiF(200). PG, a mosaic crystal of pyrolytic graphite. A perfect crystal of Si (111) is the typical crystal, showing high resolution and high reflectivity, as shown in Fig. 1-51 [34]. In some cases the very high resolution of a perfect
72 crystal is not necessary because, in general, it costs a considerable intensity loss. In some cases, crystals with a mosaic structure can serve to pass a wider wavelength band. Crystals of pyrolytic graphite (PG) show a wide mosaic spread of about 10 mrad, and low reflectivity, while the integrated intensity of reflected X-rays is usually large, which makes the mosaic crystals useful (see Fig. 1-51). For long wavelengths the so-called soap crystals can be used, although they have not yet found widespread application with SR. Reflectivities are of the order of 1-5 % for typically 100 layers in the 2 0 - 130/~ region. The evaporated multilayer is also another candidate for long wavelength X-ray diffraction. Double crystal monochromators (Fig. 1-52) are most widely used for continuous scanning of SR spectra with high resolution. The monochromators in the parallel (+,-) mode keep the direction of SR fixed while generating only a parallel displacement of the beam. In the (+,+) arrangement, because the angular acceptance in the dispersive direction is of the order of the width of the single crystal reflection curve, extremely high dispersion can be achieved without losing the X-ray intensity. The SR, with its high brightness, can make this arrangement useful, with very high resolution.
Crystal
Crystal I X Rays
(a)
Crystal
X Rays
(b) Crystal X Ray.~.s_s
(c)
Crystal
Crystal
Fig. 1-52. Double crystal monochromators (a) in the parallel (+,-) mode, (b) in the highly dispersive antiparallel (+,+) mode, and (c) in the combined mode of
(+,-) and (+,+).
73 The instrument combined with the (+,+) and (+,-) double crystal monochromator, shown in Fig. 1-52c, combines the highest resolution with simple scanning and independence of fluctuations in the position of tb.e source. Such multiple reflections serve to suppress the tails in the single crystal reflection curves, and the resolution function can be improved. Several other combinations of double crystal monochromators are also used. If a crystal is bent in one direction, it can focus radiation emerging from a source point on the Rowland circle back to an image lying again on the Rowland circle. The crystal is cut with the reflecting lattice planes parallel to the surface. Typical bent crystal monochromators, the Johann type and the Johansson type, are shown in Figs. 1-53a and 1-53b. 2
_ 0B
~_
2
0B
.~.--:.
..- .... sa
,
,
(a)
/
)
(b)
(c)
Fig. 1-53. Three types of bent crystal monochromators. (a) Johann type, (b) Johansson type (symmetric reflection), and (c) non-symmetric Johansson type. In the Johann type, a plane crystal is bent so as to be a cylinder with curvature of 2R and is set up contacting the Rowland circle with radius R. In the Johansson type, a crystal is cut so that the reflecting surface forms the curved surface of the column with radius 2R and is then bent with the radius R. For both types of bent crystals, let I be the distance between a source point and the center of crystal: the following relationship is given as 1 = 2R cos ( z r / 2 - 013) = 2R / d
(1-81)
where 013 is the Bragg angle. A focusing monochromator with asymmetric distances from the crystal to the source ll and to the focus 12 is shown in Fig. 1-53c. The crystal surface is cut at an angle ct with respect to the lattice planes. The source and the image lie on the Rowland circle, and the distances l 1 and l2 are given by l 1 = 2R sin (013- a)
and l2 = 2R sin (0 B + a)
(1-82)
74 For example, for ~ = 1.5 A and 013 = 13 ~ with quartz (10]-1) reflecting planes, when a = 7 ~ is selected, then this would give a focus at the position of l 1 = 11.3 m with 12 = 37 m and a bending radius R = 54 m. This one-dimensionally bent crystals can focus the X-rays emerging from a point source on to a line which is perpendicular to the scattering plane. In order to obtain a point focus a combination with one more bent crystal or reflection mirror is useful. A double bend crystal, which is bent at two directions perpendicular to each other, is also employed. 1.9. P H O T O N D E T E C T O R S In this section we survey several different types of photon detectors which are currently in use in the VUV and X-ray regions. Photographic film scintillation counters, proportional counters, channeltrons, microchannel plates, solid-state detectors, ionization chambers and positionsensitive detectors will be described.
1.9.1. VUV and Soft X-Ray Detectors Photographic detection for VUV is performed using nuclear emulsions such as Eastman Kodak 101 and the slower, but finer-grain emulsion 104. Photon counters and ionization chambers can be utilized for absolute intensity measurements of VUV radiations. For wavelengths shorter than about 100 A proportional counters are usually used as standard detectors, provided corrections are made to take account of absorption in the window materials of the moderately pressurized counting chambers. Although, in principle, proportional counters can be used to wavelengths about 1000 A, there are problems in finding a suitable radiation transmitting window material to withstand the differential pressure in the spectral region of 10(~ A, to 200 A. In addition, the energy resolution and sensitivity are reduced. For wavelengths above 250 A to 1000 A rare-gas ionization chambers are commonly used. This method is based on the fact that one photon absorbed in a rare gas produces just one electron-ion pair which can be measured by means of a collector electrode and a high sensitivity electrometer amplifier. At wavelengths shorter than 250 A, since 250 A (49.6 eV) corresponds to twice the ionization potential of He (2 x 24.56 eV), it is necessary to consider the effect of secondary ionization by emitted photo-electrons and of multiple photoionization. For photons below 50 eV the ionization chamber is used in the so-called two-chamber mode and above 50 eV the two chambers are connected for the measurement at low gas pressure. Behind the ionization chamber photocathodes are mounted and the total photoelectric current leaving the cathodes is measured. A variety of photoelectron multiplier systems is in use. The first of these were built with mechanically formed dynodes (mostly CuBe) mounted separately. Recently strip dynodes, which consist of semiconducting thin films on glass plates, are mostly used. An electric field is
75 generated across the continuous strip dynodes by an applied potential, causing an electron avalanche along the dynodes. The channeltrons are also of this type of detectors, with continuous dynodes. They consist of a semiconducting glass channel having an internal diameter of a few mm and a ratio of length to diameter of the order of 50 : 1. The microchannel plates (MCP), composed of many microchannels with diameters as small as 10 l.tm and lengths about 1 mm are manufactured in such a way as to form an area up to 10 cm in diameter. This device can detect photons and electrons with an extremely fast time-response (of the order of 50 ps). By using a resistant anode encoder readout behind the MCP one can use it as a position sensitive detector.
1.9.2. X-Ray Detectors The most interesting and frequently used detectors for X-ray measurement are the lithium drifted silicon and germanium semiconductor detectors [Si(Li) and Ge(Li)]. They have the highest energy resolution because only 3 - 4 eV is required to produce one electron - hole pair. The detectors can be used at count rates up to about 50,000 cps with no deterioration of the energy resolution. At too a high count rate the energy resolution decreases as a result of incomplete charge collection. Scintillation counters usually have very poor energy resolution. This is because about 400 eV is required for NaI(TI) and 2,000 eV for plastic scintillators to produce one photoelectron at the multiplier cathode. However, the decay times are very short (1 ns or less) which is an important property for experiments with very high count rates. Proportional counters are useful detectors in the soft X-ray region. Using very thin windows a high overall detection efficiency can be achieved and the energy resolution is just sufficient to suppress higher harmonics. For experiments utilizing a very high intensity primary beam, such as absorption measurements, digital electronics can not be used. One can use inert-gas or airfilled ionization chambers. The signal current is collected and amplified by a d.c. amplifier which usually has a sensitivity limit of 10- 1 4 A. The efficiency of all the detector systems depends on matching the size of the sensitive part of the detector to the mean free path of the detected photons. With higher X-ray energies the mean free path becomes large and the size or the pressure of the detector has to be increased. Position-sensitive detectors have been developed for the registration of diffraction patterns and for experiments such as topography. Photographic film (with a nuclear emulsion), a linear semiconductor detector, linear proportional counter, multiwire proportional counter or X-ray TV camera can be used. Photographic films are useful for experiments which need high spatial resolution, down to 0.3 ~tm. With photographic recording real time experimentation can not be carded out. Linear solid state detectors and proportional counters are used in such a way that they allow for the localization of individual events. Multiwire proportional counters are used for two dimensional detection, being equipped with crossed wires, and making use of the positive
76 signal from the ion current. The separation of the wires can be as low as 1 mm, and a positional accuracy of 0.15 mm can be achieved. Readout of individual wires into the computer allows very high count rates. A TV camera using a fluorescent screen and an image intensifier can be used with high and low intensity signals. Extensive use of these systems is expected in the future since they make use of highly developed TV techniques. REFERENCES 1. F. R. Elder, A. M. Gurewitsch, R. V. Langmuir and H. C. Pollock, Phys. Rev., 71, 829 (1947); J. Appl. Phys., 18, 810 (1947); F. R. Elder, R. V. Langmuir and H. C. Pollock, Phys. Rev., 74, 52 (1948). 2. A. Lienard, L'Eclairage Elect.,16, 5 (1898). 3. G. A. Schott, Ann. Phys. (Leipzig), 24, 635 (1907); G. A. Schott, "Electromagnetic Radiation", Cambridge Univ. Press, Cambridge, 1912, Ch. 7, 8. 4. W. W. Jassinsky, J. Exp. Theor. Phys. (USSR), 5 983 (1935); Arch. Elektrotech. (Berlin), 30 590 (1936). 5. D. Kerst, Phys. Rev., 60 47 (1941). 6. D. Ivanenko and I. Pomeranchuk, Dokl. Akad. Nauk SSSR, 44 315 (1944); Phys. Rev., 65 343 (1944). 7. L. Arzimovitch and I. Pomeranchuk, J. Phys. (Moskow), 9 267(1945); J. Exp. Theor. Phys. (USSR) 16 379 (1946). 8. J. P. Blewett, Phys. Rev., 69 87 (1946); Nucl. Instrum. Methods, A266 1 (1988). 9. D. Ivanenko and A. A. Sokolov, Dokl. Akad. Nauk SSSR, 59 1551 (1948); A. A. Sokolov and I. M. Ternov, Dokl. Akad. Nauk SSSR, 89 665 (1953); A. A. Sokolov and I. M. Temov, Sov. Phys. JETP (Engl. Transl.), 1 227 (1955); Sov. Phys. JETP (Engl. Transl.), 4 396 (1957); Sov. Phys. Dokl (Engl. Transl.), 8 1203 (1964). 10. J. Schwinger, Phys. Rev., 70 798 (1946); Phys. Rev., 75 1912 (1949). 11. I. M. Ado and P. A. Korolev, V. S. Markov, E. M. Akimov and O. F. Kulikov, Sov. Phys. Dokl. (Engl. Transl.), 1 568 (1956); F. A. Korokov and O. F. Kulikov, Sov. Phys. Dokl.(Engl. Transl.), 5 1011 (1961); F. A. Korokov, O. F. Kulikov and A. S. Yarov, Sov. Phys. JETP (Engl. Transl.), 43 1653 (1962). 12. D. A. Corson, Phys. Rev., 86 1052 (1952); Phys. Rev., 90 748 (1953). 13. P. L. Hartman and D. H. Tomboulian, Phys. Rev., 87 233 (1952); D. H. Tomboulian, U. S. A. E. C. NP-5803 (1955); D. H. Tomboulian and P. L. Hartman, Phys. Rev., 102 1423 (1956); D. E. Bedo and D. H. Tomboulian, J. Appl. Phys., 29 804 (1958); P.L. Hartman, Nucl. lnstrum. Methods, 195 1 (1982). 14. K. Codling and R. P. Madden, Phys. Rev. Lett., 10 516 (1963); Phys. Rev. Lett. 12 106 (1964); J. Opt. Soc. Am., 54 268 (1964); J. Appl. Phys., 36 830 (1965). 15. G. Bathow, E. Freytag and R. Haensel, J. Appl. Phys., 37 3449 (1966). 16. K. R. Lea, Physics Reports, Section C of Physics Letters, 43 337 (1978).
77 17. G. K. Green, Brookhaven Nat. Lab. Rep. BNL 50522, 90 (1977); Brookhaven Nat. Lab. Rep. BNL 50595, Voi.ll (1977). 18. E. E. Koch, C. Kunz and E. W. Weiner, Optik, 45 395 (1976). 19. A. van Steenbergen, Nucl. Instrum. Methods, 172 25 (1980); Nucl. Instrum. Methods, 177 53 (1980). 20. N. F. Gmuer, Brookhaven Nat. Lab. Rep. BNL 45764, NSLS User's Manual: Guide to The VUV and X-Ray Beam Lines, 4th Ed., February 1991. 21. K. Kohra and T. Sasaki, Nucl. Instrum. Methods, 208 23 (1983); S. Sato, Koide, Y. Morioka, T. Ishii, H. Sugawara and I. Nagakura, Nucl. Instrum. Methods, 208 31 (1983); A. Asami, H. Kobayashi and M. Ando, Houshakoh, J. Jpn. Soc.for Synchrotron Radiation Research, 1 47 (1988). (in Japanese) 22. H. Kamitsubo, Nucl. Instrum. Methods, A303 421 (1991). 23. L. R. Elias, W. M. Fairbank, J. M. J. Madey, H. A. Schwettman and T. I. Smith, Phys. Rev. Lett., 36 717 (1976). 24. D. A. G. Deacon, L. R. Elias, J. M. J. Madey, G. J. Ramian, H. A. Schwettman and T. I. Smith, Phys. Rev. Lett., 38 892 (1977). 25. W. B. Colson, Phys. Quantum Electron, 5 157 (1978). 26. C. Pellegrini, IEEE Trans. Nucl. Sci., NS-26 3791 (1979). 27. N. A. Vinokurov and A. N. Skrinsky, Institute of Nuclear Physics, Novosibirsk, USSR, Preprint 77-59, (1977) 28. M. Billardon, P. Elleaume, J. M. Ortega, C. Bazin, M. Bergher, M. Velghe, Y. Petroff, D. A. G. Deacon, K. E. Robinson and J. M. J. Madey, Phys. Rev. Lett., 51 1652 (1983). 29. G. N. Kulipanov, V. N. Litvinenko, I. V. Pinaev, V. M. Popik, A. N. Skrinsky, A. S. Sokolov and N. A. Vinokurov, Nucl. Instrum. Methods, A296 1 (1990). 30. H. Maezawa, M. Ando, T. Ishikawa, M. Nomura, H. Kitamura, A. Mikuni and T. Sasaki, Proc. SPIE - Int. Soc. Opt. Eng., Vol.733, Soft X-Ray Optics and Technology, 1986, p.96. 31. A. P. Lukirskii, E. P. Savinov, O. A. Ershov and Yu. F. Shepelev, Opt. Spectrosc. (Engl. Transl.), 16 168 (1964). 32. V. Rehn and W. J. Choyke, Nucl. Instrum. Methods, 177 173 (1980). 33. V. Rehn, V. O. Jones, J. M. Elson and J. M. Bennett, Nucl. Instrum. Methods, 172 307 (1980). 34. J. Harada, K. Ooshima and T. Sakabe, Nippon Kessho Gakkaishi, 24 256 (1982).
78
Appendix:
Table of Various Bessel Functions and Integrals
y
KI/3 (y)
1.000e-04 1.000e-03 2.000e-03 4.000e-03 6.000e-03 8.000e-03 1.000e-02 2.000e-02 3.000e-02 4.000e-02 5.000e-02 6.000e-02 7.000e-02 8.000e-02 9.000e-02 1.000e-01 1.500e-01 2.000e-01 2.500e-01 3.000e-01 3.500e-01 4.000e-01 4.500e-01 5.000e-01 5.500e-01 6.000e-01 6.500e-01 7.000e-01 7.500e-01 8.000e-01 8.500e-01 9.000e-01 1.000e+00 1.250e+00 1.500e+00 1.750e+00 2.000e+00 2.250e+00 2.500e+00 2.750e+00 3.000e+00 3.250e+00 3.500e+00 3.750e+00 4.000e+00 4.250e+00 4.500e+00 4.750e+00 5.000e+00 5.500e+00 6.000e+00 6.500e+00 7.000e+00 7.500e+00 8.000e+00 8.500e+00 9.000e+00 9.500e+00 1.000e+01
3.628e+01 1.672e+01 1.319e+01 1.038e+01 8.995e+00 8.116e+00 7.486e+00 5.781e+00 4.932e+00 4.386e+00 3.991e+00 3.685e+00 3.437e+00 3.231e+00 3.054e+00 2.900e+00 2.343e+00 1.979e+00 1.714e+00 1.509e+00 1.343e+00 1.206e+00 1.089e+00 9.890e-01 9.018e-01 8.251e-01 7.571e-01 6.965e-01 6.422e-01 5.932e-01 5.489e-01 5.086e-01 4.384e-01 3.079e-01 2.202e-01 1.594e-01 1.165e-01 8.581e-02 6.354e-02 4.727e-02 3.531e-02 2.645e-02 1.988e-02 1.497e-02 1.130e-02 8.545e-03 6.472e-03 4.904e-03 3.729e-03 2.159e-03 1.255e-03 7.317e-04 4.280e-04 2.509e-04 1.474e-04 8.679e-05 5.118e-05 3.023e-05 1.787e-05
K2/3 (y) 4.989e+02 1.075e+02 6.769e+01 4.262e+01 3.251e+01 2.682e+01 2.310e+01 1.450e+01 1.102e+01 9.052e+00 7.762e+00 6.837e+00 6.136e+00 5.581e+00 5.130e+00 4.753e+00 3.513e+00 2.802e+00 2.329e+00 1.987e+00 1.725e+00 1.517e+00 1.347e+00 1.206e+00 1.086e+00 9.828e-01 8.933e-01 8.148e-01 7.455e-01 6.839e-01 6.288e-01 5.794e-01 4.945e-01 3.406e-01 2.402e-01 1.722e-01 1.248e-01 9.132e-02 6.726e-02 4.981e-02 3.706e-02 2.767e-02 2.073e-02 1.558e-02 1.173e-02 8.853e-03 6.693e-03 5.069e-03 3.844e-03 2.220e-03 1.287e-03 7.495e-04 4.376e-04 2.562e-04 1.504e-04 8.842e-05 5.209e-05 3.073e-05 1.816e-05
K5/3 (y) 6.652e+06 1.433e+05 4.514e+04 1.422e+04 7.233e+03 4.478e+03 3.087e+03 9.723e+02 4.946e+02 3.061e+02 2.110e+02 1.556e+02 1.203e+02 9.625e+01 7.905e+01 6.627e§ 3.357e+01 2.066e+01 1.414e+01 1.034e+01 7.915e+00 6.263e+00 5.082e+00 4.205e+00 3.534e+00 3.009e+00 2.589e+00 2.249e+00 1.967e+00 1.733e+00 1.535e+00 1.367e+00 1.098e+00 6.712e-01 4.337e-01 2.906e-01 1.998e-01 1.399e-01 9.941e-02 7.142e-02 5.178e-02 3.781e-02 2.778e-02 2.051e-02 1.521e-02 1.132e-02 8.455e-03 6.332e-03 4.754e-03 2.697e-03 1.541e-03 8.855e-04 5.113e-04 2.965e-04 1.725e-04 1.007e-04 5.890e-05 3.454e-05 2.030e-05
GO (y) 9.960e+02 2.131e+02 1.336e+02 8.349e+01 6.329e+01 5.193e+01 4.450e+01 2.736e+01 2.045e+01 1.657e+01 1.403e+01 1.222e+01 1.085e+01 9.777e+00 8.905e§ 8.182e+00 5.832e+00 4.517e+00 3.663e+00 3.059e+00 2.607e+00 2.254e+00 1.973e+00 1.742e+00 1.549e+00 1.386e+00 1.246e+00 1.126e+00 1.020e+00 9.280e-01 8.464e-01 7.740e-01 6.514e-01 4.359e-01 3.004e-01 2.113e-01 1.508e-01 1.089e-01 7.926e-02 5.811e-02 4.286e-02 3.175e-02 2.362e-02 1.764e-02 1.321e-02 9.915e-03 7.461e-03 5.626e-03 4.250e-03 2.436e-03 1.404e-03 8.131e-04 4.725e-04 2.755e-04 1.611e-04 9.439e-05 5.543e-05 3.262e-05 1.922e-05
G3 (y) 9.960e-10 2.131e-07 1.069e-06 5.343e-06 1.367e-05 2.659e-05 4.450e-05 2.189e-04 5.522e-04 1.060e-03 1.754e-03 2.640e-03 3.722e-03 5.006e-03 6.492e-03 8.182e-03 1.968e-02 3.614e-02 5.723e-02 8.259e-02 1.118e-01 1.443e-01 1.798e-01 2.177e-01 2.577e-01 2.994e-01 3.422e-01 3.862e-01 4.303e-01 4.751e-01 5.198e-01 5.642e-01 6.514e-01 8.514e-01 1.014e+00 1.132e+00 1.206e+00 1.240e§ 1.238e+00 1.209e+00 1.157e+00 1.090e+00 1.013e+00 9.302e-01 8.454e-01 7.611e-01 6.799e-01 6.029e-01 5.312e-01 4.053e-01 3.033e-01 2.233e-01 1.621e-01 1.162e-01 8.248e-02 5.797e-02 4.041e-02 2.797e-02 1.922e-02
Applications of Synchrotron Radiation to Materials Analysis H. Saisho and Y. Gohshi (Editors) 9 1996 Elsevier Science B.V. All rights reserved.
79
CHAPTER 2
X-RAY F L U O R E S C E N C E ANALYSIS Hideo SAISHO and Hideki HASHIMOTO Inorganic Analysis Laboratory, Toray Research Center, Inc. 1-1, Sonoyama 1-Chome, Otsu, Shiga 520, Japan
2.1. I N T R O D U C T I O N Recent trace element analysis requires highly sensitive, simultaneous multi-element methods. Such methods include activation analysis, atomic emission spectrometry, mass spectrometry, and X-ray fluorescence analysis (XRF). XRF facilitates rapid, nondestructive analysis, and has a wide range of applications, including production processes and quality control. Although XRF is not necessarily a high-sensitivity technique (normally, it can only detect ~tg levels), researchers have recently found that synchrotron radiation (SR) greatly improves the sensitivity of XRF, enabling analysis over l.tg-pg ranges [1-3]. Synchrotron radiation is a continuum radiation with a wide wavelength range. Two to three GeV class storage tings currently available supply radiation ranging from microwaves to hard X-rays (20-30 keV). Furthermore, these storage tings provide an X-ray intensity 100-10 000 times greater than conventional X-ray sources. If a wiggler is used, hard X-rays of up to 50 keV can be supplied. In addition, when large scale SR facilities under construction are completed, the available intensity will increase by a few more orders of magnitude. Other advantages of SR include its almost perfect linear polarization and excellent collimation. More sensitive XRF can be attained by increasing the intensity of the signal and reducing the background. Greater signal intensity can be obtained by increasing the intensity of the excitation X-rays. The background is reduced by two characteristics of SR: continuum radiation and polarization. The excellent collimation of SR makes this method suitable for measurements using the total reflection method, which is useful for surface analysis, as well as for microarea analysis using a microbeam. The major characteristics of SR - - high intensity, continuum radiation, polarization, and c o l l i m a t i o n - greatly enhance the capabilities of XRF. Table 2-1 lists the characteristics of synchrotron radiation and the advantages when it is applied to XRF.
80 Table 2-1 Outstanding characteristics of SR for XRF SR characteristics
Advantages
High intensity Linear polarization Continuous spectrum
Signal enhancement Background reduction Selective excitation Total reflection
High collimation
{
Micro-trace analysis
SR-Excited XRF (SRXRF) was first developed in 1972 by Horowitz and Howell [4] for use in microbeam analysis. Working with the Cambridge Electron Accelerator, they used an ellipsoidal condensing mirror and a pinhole to produce a 2 I.tm focused X-ray beam. XRF using this beam attained a detection limit of 10-6 to 10- 9 g cm -2 at a resolution of 2 lxm. Sparks et al. [5, 6] conducted their well-known 1977 experiment at SPEAR of SSRL in order to find primordial superheavy elements using a curved pyrolytic graphite crystal and a Si(Li) detector. They demonstrated that it was possible to detect superheavy elements if at least 5 x 108 atoms were present in the sample. The announcement of this result, as well as the establishment of SR facilities at many locations, led to an increasing number of investigations of XRF analysis in the 1980s. Gilfrich et al.[7], at SSRL in 1983, systematically performed a series of experiments concerning detection limits. Similar research was carded out by Hanson et al. [8] at CHESS of Cornell, Kn6chel et al. [9] at DORIS of HASYLAB, and Bos et al. [10] at the SRS of Daresbury. Iida et al. [ 11] conducted a close investigation into the dependence of the detection limit on the excitation mode at the Photon Factory (PF) of the National Laboratory for High Energy Physics (KEK). Also, Gordon used beam intensity parameters to calculate theoretical values for detection limits at the NSLS of Brookhaven [ 12]. X-Ray total reflection produces a shallow X-ray penetration depth and very little scattering (background), and therefore total reflection XRF (TXRF) is useful for surface analysis and ultratrace analysis [13, 14]. While improvements have been made by Yoneda and Horiuchi [ 15] in the original technique, which used a conventional X-ray tube, the use of SR further enhances the effectiveness of TXRF because of SR's excellent collimation and strongly monochromatic beam [ 16]. Researchers often apply this method to analyze depth profiles [ 17] and layered structures [18]. In these analyses, the reflection curve and fluorescent X-ray profile are measured as changes are made in the incident angle near the critical angle of total reflection. In this chapter, we will discuss equipment used for bulk analysis and surface analysis using SRXRF. These techniques do not include analysis using a microbeam or chemical state analysis for obtaining information on chemical bonding by high energy-resolution measurements. These will be described in the next chapter.
81 2.2. E Q U I P M E N T SRXRF detects X-ray fluorescence caused by a white (non-monochromatic) or monochromatic incident SR beam. The radiation of hard and soft X-rays from the storage ring requires quite different equipment. With hard X-rays, beryllium windows can be used to form a barrier between the ultrahigh vacuum in the storage ring and the low vacuum or air in the sample chamber. Soft X-ray SRXRF requires ultrahigh vacuum through to the sample chamber. This means that completely different equipment is required for the analysis of light elements (atomic number less than 12) and of elements with higher atomic numbers. Hereafter, we will confine our discussion to analytical techniques using hard X-rays. Hard X-ray equipment is built in much the same way as equipment using X-ray tubes or rotating anode Xray generators. The major difference is that in SR equipment, the distance from the light source to the sample is longer (10-30 m). Despite this long distance, high collimation keeps the reduction of SR intensity to very low levels. Equipment known as beamlines introduces the X-rays into the detection system. A beamline is composed of a few beryllium windows, a vacuum system, shutters, and optical elements. Since SR obtained from a bending magnet is linearly polarized in the orbital plane of the accelerated electron, the optical elements usually have an axis of rotation horizontal to the electron's orbital plane. To protect the operator from radiation, the detection system is placed in an iron (or lead) hutch and is remote-controlled. Section 2.2.1. describes the optical elements used in SRXRF. Section 2.2.2. deals with the detectors, and Section 2.2.3. discusses the beamline for X-ray fluorescence incorporating these two components.
2.2.1. Optical elements Total reflection m i r r o r
The X-ray mirror is extensively used in SR experiments as a low pass filter, a high pass filter, or an X-ray focusing device. Since the refractive index for X-rays is very slightly less than unity (a difference of 10-5), an X-ray with a glancing angle smaller than a certain value (critical angle: a few mrad) is totally reflected. The critical angle depends on the kind of substance and the wavelength of the incident X-rays. The complex index of refraction n for an X-ray with a wavelength A is given as follows: (2-1)
n = l - 5 - i fl S = (rJ2~)(Nop/A)(Z
fl = ~/.t/4r~
+ Af' )Z 2
(2-2) (2-3)
82
(a)
(b)
1.0-
ad
1.0-
~: 1.5/~
0.8-
0.8-
ov,,~
~0.6-
Si " 0 = 4mrad
~,c" 1.6/~
0c " 10.5 mrad
Z,c" 1.7/t~ ;>0.6=!,~(
Si
t,,.,)
~0.4-
r
0.4-
ad 0.2-
0.2-
0.0- i 0
4
i
8
'
t
12
'
Glancing angle / mrad
o'o-t'- t ' "
1.2
1.4
i
1.6
t
1.8
Wavelength /
t
2.0
t
2.2
Fig. 2-1. The calculated reflectivities for silicon and platinum: (a) is expressed as a function of glancing angles at a fixed wavelength (1.5 A) of the incident X-rays; (b) as a function of wavelengths at a fixed glancing angle (4 mrad for Si, 12 mrad for Pt).
where re is the classical electron radius, No is Avogadro's number, p is the density, and A is the atomic weight. Thus, (Nop/A) represents the number of atoms found in a unit volume. The quantity (Z+Af) is the real part of the atomic scattering factor, where Z is the number of electrons per atom (atomic number) and zlf' represents the dispersion term. Far away from the absorption edge, Af' is very small, and therefore 6 is proportional to the electron density. The quantity/.t is the linear absorption coefficient. An incidence of an X-ray at a glancing angle less than the critical angle, 0c, which is a grazing angle, will result in total reflection. If we ignore absorption, the critical angle can be given as follows, according to Snelrs law: 0c = ~
(2-4)
Calculated reflection curves for silicon and platinum are shown in Fig. 2-1. Figure 2-1a shows the reflection curves as a function of the angle (glancing angle), and (b) shows them as a function of the incident X-ray wavelength. The critical angle (0c) and critical wavelength (20 can be seen. For a given substance and angle, X-rays of wavelengths less than a certain value (greater energy than a certain value) are not reflected: thus, the mirror works as a low pass filter. As can be seen in Fig. 2-1, for a given wavelength, the more electrons per unit volume, the larger the critical angle. However, as the amount of X-rays absorbed increases, the change in reflectivity near the critical angle is more gradual, which implies a lower
83 efficiency as a low pass filter. Since the critical angle for X-ray wavelengths is a few mrad, the use of an X-ray 2 mm high requires a mirror a few tens of centimeters long. Also, the mirror must be sufficiently smooth if its calculated efficiency is to be attained. Calculated reflection curves for mirrors of different roughnesses are shown in Fig. 2-2. Surface roughness is described as a group of flat planes distributed in a Gaussian manner. Figure 2-2 shows that less than 10/~ roughness is necessary. Surface roughness reduces the reflectivity. When using a mirror and employing a strong SR, it is necessary to ensure thermal stability. Therefore, it is important to place the optical system in a high vacuum or to cool the system. Another way is to position the mirror behind the monochromator, but then the monochromator would have to be protected from the heat. The mirror material is another point for careful consideration. A plane plate of thickness d with a difference in temperature, AT, between the surfaces, bends at a radius of curvature, R, which can be described as follows: R = d/(aAT)
= (kd2)/(otAq)
(2-5)
where k is the thermal conductivity, ct the coefficient of thermal expansion of the material, and Aq the amount of heat transferred through a plate of thickness d. Equation (2-5) indicates that the mirror material should have a high thermal conductivity and a small coefficient of thermal 1.0
t~=0 ~," 1.24 .~
0.8
~06
~
9
a=20
r
~ 0 4-
0.2
0.0 1
2
3
4
5
6
G l a n c i n g angle / m r a d Fig. 2-2. The calculated reflection curves for samples of silicon of roughnesses (t~ = 0, 10 ]~ and 20 ]~).
different surface
84 expansion, i.e., a large k/a. In addition, the mirror material must be able to be ground and polished to a sufficient degree. Fused quartz is widely used since large polishable mirrors can be fabricated. However, despite its small coefficient of thermal expansion, the thermal conductivity of this material is low and therefore it cannot be used where a substantial heat load is expected. Recently, SiC has received attention. It has a high thermal conductivity and a k]o~ value more than 20 times that of quartz. Since it is now possible to make large SiC mirrors, it will be used in most beamlines using an insertion device and in the next generation of large scale rings. The mirror chamber must be kept under ultrahigh vacuum to prevent carbon from adhering to the mirror surface, since this would greatly lower the mirror's efficiency. Total reflection mirrors are generally used for eliminating harmonics. They are also used, in combination with absorbers or transmission mirrors, to emit X-rays with a wide energy band or to focus X-rays. If the absorption characteristics of a very thin mirror are low, the unreflected X-ray comes out of the back of the mirror. Such mirrors are known as transmission mirrors. If a mirror is thin enough (less than 1 lxm thick) and is made of material with a low atomic number, it can be used as a transmission mirror. The calculated transmissivities of thin organic films are shown in Fig. 2-3. Transmission mirrors can be used as highly efficient high pass filters. Soap film is a smooth, stable transmission mirror. It is 300-10 000/~ thick, and very smooth, with a surface roughness less than a few/~. Lairson and Bilderback [19] used a solution of glycerin (35%), Ivory Liquid (2%), and distilled water (63%) to make soap films. They used a 20 Jam wire stretched inside a 10 cm x 30 cm frame to make 8 cm x 20 cm films. The films kept a few days in wet helium.
Figure 2-4 shows the transmitted spectra of the
1.0--
1.0" ~0.8
f
-
thickness: d = 0.5 ilm
9 t,,=q
r thickness: d = 0.1 I.tm
;~0.8 -
~,' 1.24 /~
~, 91.24 A
~0.6-
o~ 0 . 6 -
9 v,,,,l
9 t,,,,q
~04-
~0.4-
0.2-
0.2-
0.00
2
I
I
I
I
4
6
8
10
Glancing angle / mrad
0"0-1 0
'
'
2
I
I
I
I
4
6
8
10
Glancing angle / mrad
Fig. 2-3. The calculated glancing angle dependence of transmissivities for polystyrene films using incident X-rays with a wavelength of 1.24/~.
85
10
.--" .._-_ -
jJ
_
.;
9~
"~
0
-
~
-
-
I
_
I
t
0
i
I
i
t
I
12.5 Energy / keV
I
I
25
Fig. 2-4. Transmitted spectra of soap films at a thickness of > 10 000 ]k (broken line) and of 3 200 A (solid line). Both films are set to the same mirror angle (2.4 mrad). From Ref.[19], reprinted by permission of Elsevier Science Publishers B.V., Amsterdam.
films. It indicates the dependence of transmissivity on film thickness. Iida et al. [20] used 0.5 ~tm Mylar film as a transmission mirror. Compared with soap films, the Mylar film is more stable and durable, yet it is less smooth and more difficult to make flat. Mirrors with an ellipsoidal, cylindrical, or hyperboloidal cross section also can be used to condense X-rays. In microprobe analysis, a combination of these mirrors is used to create a micro-sized beam (microbeam). Reflection and transmission mirrors can be combined to select X-rays with appropriate energy bands. This will be discussed later in this section. Crystal monochromator In order to use SR as a monochromatic X-ray excitation beam it must be monochromatized using a monochromator. Crystals are used for this purpose. The diffraction of an X-ray by a crystal is described by Bragg's law 2d sin0 B= nA
(2-6)
where n is the diffraction order, d is the lattice spacing in the crystal lattice, ~, is the X-ray wavelength and 0]3 (the Bragg angle) is the angle which the incident X-ray makes to the
86 reflecting plane. Since sin0 is less than unity, X-rays with wavelengths longer than 2d cannot be reflected. Bragg angles of less than a few degrees or more than 70 degrees cannot be achieved because of the structure of the monochromator. Therefore, the lattice spacing of the crystal lattice plane must match the wavelength used. For example, for Si (111), where d is 3.136/~, the wavelengths that can be obtained range from 0.4 to 6 ]k. Equation (2-6) is differentiated to: AA/A = AE/E = A0 cot0a
(2-7)
From Eq. (2-7) it is evident that energy resolution is determined by the angular width A0 and Bragg angle 0B. The angular width is determined by the angular spread of the incident beam and the reflection width of the crystal monochromator. The angular spread of the incident beam depends on the size and angular divergence of the light source and the geometry of the experiment (distance, slit, etc.). The reflection width is greatly affected by the crystal'sstate of perfection. For a perfect crystal, the reflection width to is given as follows, according to the dynamical theory of diffraction [21 ]: to =
2 9re ~ 2 .C. [/7111.e -M sin20B uV
(2-8)
where re is the classical electron radius, V the unit-cell volume, Fh the crystal structure factor, e -M the temperature factor, and C the polarization factor. The integral reflecting power, I, for a weakly absorbing crystal is given approximately by 2
I = 1__. 8 .rex .C. [F~ .e -M ~ 3sin20B ~V
(2-9)
where b is a quantity called the asymmetry factor. For a mosaic crystal, kinematical diffraction theory can be applied to rewrite I as follows: \ I=
r2~3
(2-10) .C 2. ~t~2.e-2M
2/aVEsin2 0B The reflection width, energy resolution, and integral reflecting power of perfect crystals which are frequently used are shown in Table 2-2 [22]. The crystal used in a monochromator must not be seriously damaged by a strong SR. Generally speaking, it is impossible to use organic crystals in monochromators. Usually, silicon crystals are used, since large perfect crystals can be made easily and provide the lattice
87 Table 2-2 Parameters of crystal monochromators a Crystal
hkl
als
(second of arc)
b
c
AE/E
(•
5)
I
(xl 0 6 )
Silicon
111 220 311 333
7.395 5.459 3.192 1.989
14.1 6.04 2.90 0.88
39.9 29.7 16.5 9.9
Germanium
111 220
16.338 12.449
32.64 14.46
85.9 67.4
a Bragg reflection width, b Energy resolution, c Integral reflecting power. These parameters are used to determine experimental conditions such as incident X-ray energy and resolution. From Ref. [22], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
spacing required in the hard X-ray region. Since SR is polarized in the horizontal direction, a non-horizontal monochromator rotational axis will jeopardize the efficiency. When the monochromator with a horizontal rotational axis is used, the diffracted beam goes up or down: therefore, changing the Bragg angle to change the wavelength varies the direction of the diffracted beam. This means that all units positioned behind the monochromator (slit, sample, detector, etc.) must be moved every time the Bragg angle is changed. A monochromator with a parallel double-crystal (or a channel-cut crystal) always reflects the beam in the same direction. In this case, the above units can simply be moved up and down, en bloc. It is also possible to keep the height of the outgoing beam constant by attaching a mechanism to translate the crystal while rotating the doub!e-crystal monochromator [23]. This makes the equipment even easier to use. Special care must be taken to eliminate harmonics when using a monochromator. It is clear from Bragg's law that for any X-ray, with a wavelength A, there will be an X-ray with a wavelength 2/n which will be reflected at the same angle. The relative intensity of harmonics depends on the spectn~m of the light source, the integral reflecting power of the crystal, etc. If absorption is ignored, the integral reflecting power is proportional to (2/n)2lF~e-M, a quantity that monotonically decreases with increasing order n. Considering the SR spectrum, therefore, the second and third harmonics are the problems in the X-ray region. In some cases, the second harmonics disappear due to the symmetry of the crystal. One such example is Si(111). In this case, harmonics pose very little problems if the storage ring can supply a relatively high incident energy (more than 15 keV for a 2 GeV class storage ring). Basically there are two methods of eliminating harmonics. One uses a total reflection mirror. As
88 discussed previously in this section, the mirror totally reflects X-rays of wavelengths longer than a certain value (the critical wavelength) and does not reflect those with shorter wavelengths. The other method employs a beamline without a mirror. Harmonics can be eliminated by slightly detuning two crystals used in a double-crystal monochromator. As shown in Table 2-2, the reflection width for Si(333) is much smaller than that for Si(111). This makes it possible to reduce the intensity of harmonics by detuning. Also used is an optical system that increases the intensity of the beam by focusing the incident X-ray using a curved second crystal (sagittal focusing) [24-26]. SR has a high degree of collimation in the vertical direction (angular spread: approx. 0.1 mrad), but it is also spread in the horizontal direction. An ordinary beamline can take in a few mrad of a beam in the horizontal direction, but given the long distance (10-30 m) from the light source to the hutch, the beam will be spread more than a few cm on the sample. Therefore, if the incident beam is not focused, a fiat-crystal monochromator can only supply less than 1 mrad of the beam. A focusing optical system collects much of the beam and improves the detection limit by producing more than 10 times the intensity. Another focusing optical system employs a fiat-crystal monochromator and a curved mirror. When using this system, however, the position of the mirror should be carefully considered. If the mirror is positioned in front of the monochromator its adjustment can be made at the beginning, and no further adjustment is needed when tuning the monochromator to change the energy. However, in this position SR could damage the mirror surface. When the mirror is positioned behind the monochromator damage is negligible, but then it requires more complicated adjustment. Protecting the monochromator from the heat of SR must also be considered when using an insertion device or a larger scale ring. Resolution may be sacrificed if higher intensity is desired. The properties of a mosaic crystal monochromator are between the wide band-pass (see the following section) and perfect crystal monochromators [ 11]. As shown in Eqs. (2-9) and (2-10) the mosaic crystal monochromator provides greater reflection intensity. The pyrolytic graphite mosaic crystal produces greater reflection intensity, but the band width is spread to about 170 eV, yielding an X-ray of 8 keV. Silicon with a rough ground surface also displays mosaic crystal properties. It is important to choose a monochromator that best matches the size and composition of the sample.
Wide band-pass monochromator In some cases, greater intensity is required and the high resolution of a crystal monochromator is not. A wide band-pass monochromator is defined as a monochromator with an energy resolution, AE/E, of more than 0.1. There are two types of such monochromators. One combines a total reflection mirror with an absorber or a transmission mirror. The other type uses a synthetic multilayer as a monochromator element. Iida et al. [20] studied monochromators that combined a total reflection mirror and an aluminum absorber (or a transmission mirror such as a soap film or Mylar film). Their calculations are shown in Figs. 2-5 and 2-6, and the results of their experiments in Figs. 2-7
89 1.0
_
P~ ~
p,.
%.I
~
0.5 -
-
//
/
e/
//
/ /
-
0.0
_/
200_/'-'11~\ // ~'k~ / 409.. "'.'~k,.x~
/
j"-
-.-'r"~-"l
5
m
'
m
,
m
10 Energy / keV
n
~
~
m
_
m
15
i
-
T - -
Fig. 2-5. Calculated fused quartz reflection mirror responses in combination with A1 absorbers (broken lines) and without an absorber (solid line). The glancing angle of the reflection mirror is 2.5 mrad. The absorber thicknesses are shown in the figure in ~tm. The cutoff on the low energy side is not sharp. From Ref. [20], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
I
1.0 p~ p,.
-
~
. l
l
.I
/ i
/
_
I
I I
_1
I
I
0.0 5
3//
/
-
~~ 0.5
I
i
a
i
i
n
n
i
m
I
/
/
/
/,
a
t
2")[ ~ / 2.3 I / I I I I 2 I
I i
t
I I
I
I I
m
10 Energy / keV
m
15
Fig. 2-6. Calculated fused quartz reflection mirror responses in combination with (broken lines) and without (solid line) a soap film transmission mirror. The glancing angles of the transmission mirror are shown in the figure in mrad. The soap film thickness is 1 000 A. The cutoff on the low energy side is sharp compared with the cutoff of the reflection mirror / absorber combination. The glancing angle of the reflection mirror is 2.5 mrad. From Ref. [20], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
90 ,=
1.0
(a)
~
aW~tshO%ter -
1.0
(b)
-
. ~ 4 - - - . . without f ,I,IiN absorbeq / ~ ~ 70/.tm
o N
70 m ~0.5
140 m
0.0:
0.0 I
4
0.5
i
i
I
6
8
.1
i_
10
i
i
12
i
i
i_
i
14 16
!
i
6
4
i
8
!
i
10
i
i
12
I
I
I
]
14 16
Energy / keV
Energy / keV
Fig. 2-7. Measured responses of the Pt coated (a), and non-coated (b), fused quartz mirror in conjunction with the A1 absorbers. A wide energy band-pass greater than 20% was achieved. From Ref. [20], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
1.0-
1.0~ '(1))' ' ' A ~ - ~ [with p m '~,~
9
i
ttrans
No.o
,,, 4
6
8
'withou; ~ tr.ans. ]
l
o.o 10 12 14 16 18 20 Energy / keV
4
6
8 10 12 14 16 Energy / keV
18
Fig. 2-8. Measured responses of the fused quartz reflection mirror using soap film (a) and Mylar (b) transmission mirrors. For the use of the transmission mirror, each curve shows the response of a different glancing angle to the transmission mirror. A sharper cutoff at the low energy tail is achieved than with the reflection / absorber combination. From Ref. [20], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
91 and 2-8. They obtained a wide band pass of more than 0.2. That using a transmission mirror has a sharper cutoff in the low energy region (see Fig.2-8a). Figure 2-9 shows the spectrum of X-ray fluorescence measured by the energy dispersive method, using chelated metal-resin beads as a sample. When using an absorber, the signal-to-background (S/B) ratio is large in the low energy region, but the X-ray fluorescence of Zn overlaps the scattered X-ray. On the other hand, the combination of a total reflection mirror and a transmission mirror provides an excellent S/B ratio for the X-ray fluorescence emitted by Zn. Synthetic multilayers have recently been receiving attention as excellent wide band-pass monochromators. These synthetic lattices stack two substances, with different atomic numbers (e.g., silicon and tungsten), one on the other at intervals between a few and a few tens of A. Early in their development there were problems resulting from the two substances diffusing at the interface. Recently, however, it has been possible to produce excellent multilayers in the desired combinations and intervals [27]. Because of their controllable lattice spacing they are useful not only as wide band-pass monochromators but also as monochromators for the soft X-ray region m a region that has lacked an appropriate monochromator. 2.2.2.
Detectors
It is often pointed out that a stable SR permits a correct calculation of its intensity, wavelength distribution, and angular distribution. In fact, however, the incident X-ray has to be monitored to ensure accurate measurements and experiments. This is because, even if the electron or positron beam put out by the storage ring is very stable, it cannot prevent the SR intensity from fluctuating because of the thermal instability of the optical elements. Fluctuations in position and direction of the electron or positron beam also contribute to fluctuations in the intensity of the X-rays. This is why the current in the storage ring beam cannot be used to monitor the incident X-ray. Monitoring part of the X-ray flux is not desirable either, since the flux does not necessarily have a uniform wavelength and intensity distribution. The ionization chamber is generally used as a detector for monitoring in the Xray region. When an X-ray irradiates a gas, the gas absorbs the radiation and is ionized. In the ionization chamber method, the electric charge caused by this ionization is measured to obtain the intensity of the incident X-ray. The height of the emitted pulse signals is too small to be measured. Therefore, normally the direct current is measured instead. The current produced in the ionization chamber is linearly related to the number of the incident photons: I = neEe/W
(2-11)
where I is the output current of the chamber (A), n the number of the incident photons (s-l), e the detector efficiency, E the energy of an incident photon (eV), e the electronic charge (1.6 x 10 -19 C) and W the energy to produce an electron-ion pair (eV). Despite the complicated process of gas ionization, W is known to be characteristic of a gas molecule, regardless of the
92
(a) |
1.0
l
(b) !
l
i
i
"2.5 GeV 92.3 mA
!
.0 2.5 GeV 75.9 mA
Zn MAX. CTS. 3628.5
Mn
Zn MAX. CTS. 4764.8
Ar
.
~05
Scattered
'.5
Mn
o~,,4
Ar Ca
.0
0.0 I
i
2
i
i
4
i
i
i
i
a
i
I
I
6 8 l 0 12 Energy / keV
i
.
I
14 16
2
4
6
8
10 12 14
16
Energy / keV
Fig. 2-9. Fluorescence spectra from a Ca, Mn and Zn adsorbed chelate resin with 20 ppm concentrations of each element, using the reflection mirror and A1 absorber combination (a), and the reflection / transmission mirror combination (b). Counting time, 100 s; MAX. CTS., maximum counts. From Ref. [20], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam. kind of ionizing particle and the operating conditions of the ionization chamber. When n = 109 photons s-1, e = 0.2, E = 8 000 eV, and W = 30 eV, I will be 8.5 x 10-9 A. There are many kinds of ionization chambers. The structure of the one used at the Photon Factory is shown in Fig. 2-10. The parallel-plate type is employed because (1)the electric field between the
H.V I'1'
Electrode
X-Rays
Electrode
Amplifier
Fig. 2-10. Schematic diagram of a typical ionization chamber (parallel-plate type) used at the Photon Factory.
93 electrodes is uniform, (2) it is easy to set up, and (3) it is easy to use. A voltage is applied across the electrodes to keep ions and electrons apart. The ionization chamber has a wide dynamic range of more than 5 decades, high linearity, and is free of dead-time losses. The Xray absorption can be controlled by changing the pressure and kind of the gas contained in the ionization chamber, or the electrode length therein. The X-ray absorption by nitrogen and argon contained in a chamber with a 17 cm electrode is shown in Fig. 2-11. It is desirable to use 5-20% of the incident X-ray for intensity measurements, transmitting the rest to the sample. Another method of monitoring incident X-rays uses a scintillation counter to measure the radiation scattered by a foil made of a low atomic weight element such as aluminum. The method of detecting X-ray fluorescence is basically the same as that of laboratory X-ray devices. When using SR, the energy dispersive method is often employed because it is capable of rapid, simultaneous multi-element analysis. A solid state detector is saturated at a few thousand counts s-1. When XRF is used for trace element analysis, scattered radiation makes up the greatest percentage of X-rays reaching the detector. Fortunately, however, since SR is linearly polarized, scattered radiation can be dramatically reduced by positioning the detector perpendicular to the beam. The calculations for this are discussed in Section 2.3.2. A high counting rate system is also considered. Furthermore, multi-element detectors have been developed. They incorporate up to a few tens of detectors. Reduction of X-rays to individual detectors eliminates dead-time losses due to saturation, and the large solid angle which can be covered by the multiple detectors increases the overall detection efficiency. A large solid angle is of great importance when measuring by the wavelength dispersive method. 2.2.3.
Beamlines
The first thing to do when fabricating a beamline for XRF is to determine the energy region for measurement. Different beamlines are required for analysis or measurement of different energy regions: i.e., the analysis of light elements in the soft X-ray region of less than 1-2 keV, the measurement of X-rays in the region of 2-30 keV, or of the K-series X-rays of heavy elements. For measurement of heavy elements, the beamline must be fashioned in such a manner that it can accommodate a large scale SR facility or a wiggler. Strict shielding of radiation is also required. When using soft X-rays, the beamline must be made under high vacuum, since beryllium windows cannot be used in this case. The absorption of X-rays by beryllium is shown in Fig. 2-12. In a beamline for measuring the X-ray fluorescence in a 230 keV region, 2 to 4 beryllium windows are normally used. The total thickness is 300 ~tm1 mm. The design of the optical system depends on whether a microbeam is used or not. It must also be decided whether a crystal or a wide band-pass monochromator should be used. If desired, the optical system can be designed to be compatible with both types of monochromator. Different equipment in the same beamline should be substituted in the hutch for the energy dispersive and the wavelength dispersive methods. As an example, Beamline 4A installed at the Photon Factory is shown in Fig. 2-13. (In this chapter we will not discuss the focusing optical mirror system which is inserted between the
94
100-
1.080-
N2
6
0.8-
owit
'~
60-
.-,06-
o
9 1,,,~
~4oo
<
~0.4-
20
0.2-
0
' 0
I 10
'
I 20
'
I 30
Incident X-ray energy /keV Fig. 2-11. Absorption curves of X-rays passing through 17 cm lengths
0.0-
,
0
I
4
'
I
8
'
I
'
12
Incident X-ray energy /keV Fig. 2-12. The calculated transmissivities of X-rays through a 300 ~tm
of gases (N2 and air).
thick beryllium window.
monochromator and the hutch for analysis using a microbeam.) It is about 9 m from the source of light to the outer wall of the ring. A double-crystal monochromator is positioned about 1 m from the wall. Three beryllium windows are used, with a total thickness of 650 ~tm. To maintain the outgoing beam at a constant height, regardless of its energy, this monochromator is equipped with a mechanism to translate the first crystal parallel to the incoming beam whilst allowing it to be rotated [28]. It also can put out a strong beam by focusing rays in the horizontal direction using a curved second crystal. When Si(111) is used
Branch beam shutter i
R I1
Double-crystal monochromator Crystal Slit
P,
Fig. 2-13. Schematic drawing of Beamline 4A at the Photon Factory.
Hutch
95 as the monochromator crystal, the energy width for an 8 keV X-ray is 3.3 eV. The photon flux in this energy band is of the order of 108 photons s-1 for a beam 1 mm square. The equipment in the hutch must be remote-controlled, since it is impossible to enter during use of the X-ray beam. The equipment used for the energy dispersive method and built into a hutch includes a slit, a sample chamber, an incident X-ray monitor, and a solid state detector. A small TV camera is very useful for monitoring the position of the sample. A laser beam is sometimes used to help in positioning the equipment and the sample. The sample chamber should be able to hold a vacuum and be equipped with a remote control device for inserting several samples. The solid state detector must be positioned perpendicular to the beam. This minimizes scattering, since the SR is linearly polarized in the orbital plane of the storage ring [29]. Figure 2-14 shows the vertical divergence distribution of the SR (11 keV) from one electron [ 11]. The abscissa shows the angle from the electron orbit, and the vertical distance is measured at a position 14 m from the light source. The vertical polarization component vanishes on the orbital plane of the electron beam. This means that most X-rays are horizontally polarized when the beamline is horizontal to the orbital plane of the electron. Therefore, if the sample and the detector are positioned within 1 mm of the beam center, the
1.0
el
0.5
% 0.0
0
\
.1 .2 Angle / mrad
Displacement / mm Fig. 2-14. Calculated vertical divergence distribution of the SR from one electron at E = 11 keV. Parallel and perpendicular polarization components and their sums are shown by the solid, broken and dotted lines, respectively. The abscissa indicates the angle from the electron orbit and also the vertical displacement at 14 m from the source point. From Ref. [11], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
96 vertical polarization component is very small. Iida et al. [11] measured the intensity distribution, in the vertical direction, of incident and scattered X-rays and X-ray fluorescence, as well as the distribution of the ratio of the intensity, in this direction, of the X-ray fluorescence and the scattered X-ray. The results are shown in Fig. 2-15. The monochromator has a single Si crystal, lapped with #600 SiC. The solid state detector is positioned perpendicular to the beam. While the intensity of X-ray fluorescence is proportional to the intensity of the incident X-ray, that of the scattered radiation is at a minimum at the beam center. Non-monochromatic excitation has the best detection limit in absolute (weight) amount because such excitation uses a very strong incident X-ray. However, when the scattering is strong or when the sample contains matrix elements with high atomic numbers, the emitted Xray fluorescence saturates the detector, resulting in a high detection limit in relative concentration. Monochromatic excitation coupled with a crystal monochromator allows the incident X-ray energy to be adjusted to the most efficient value for the element to be measured. For this reason, this method provides a lower detection limit in relative concentration. However, it yields a higher detection limit in absolute amount than excitation by a nonmonochromatic beam, because the total X-ray intensity for excitation is lower. The wide
[
I
I
I
I
I
I
.-.mr 30 I--
"~,
I
-1.0 ,d
\
-0.5~
20
e,
10-
I ' 0 1 2 Vertical d i s p l a c e m e n t / m m
,.$
0
Fig. 2-15. The variation of the incident ( 9 ), and scattered ( i ) , Zn K(t fluorescence (A) radiations, and the ratio of the Zn signal to the scattered radiation (o) as a function of the vertical displacement. The sample is a 20 ppm Zn adsorbed chelate resin. The monochromator used is silicon lapped with SiC. The excitation energy was 11 keV. Null vertical displacement indicates the center of the beam. The vertical resolution was 250gm. l~rom Ref. [11], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
97 band-pass monochromator has features which lie somewhere between these two. The most efficient method should be chosen according to the composition of the sample and the elements to be measured. SR has a very small angular divergence in the vertical direction (approx. 0.1 mrad). Therefore, the maximum size of the beam's vertical component arriving at the sample is limited to a few millimeters. When a large beam is required, and it is necessary to enlarge it, the asymmetric reflection (asymmetric Bragg magnifier) of a crystal can be used (see Chapter 8, Section 8.3.5). Use of the asymmetric reflection easily permits the diffracted beam to have a cross section about 10 times larger than that of the original beam. From Liouville's theorem, a geometry which increases the cross section of a beam also improves its collimation. On the other hand, the beam's cross section can be reduced by using this method in the opposite way. Unlike the method using a slit, it maintains the intensity of the beam. Other components of a beamline include a vacuum system (vacuum pumps, vacuum indicators, valves), shutters, and an interlock system. In addition, a beam position monitor is useful for experiments using a microbeam. The control system for X-ray fluorescence detection is basically the same as the one used in the laboratory. 2.3. XRF USING M O N O C H R O M A T I C EXCITATION 2.3.1.
Characteristics
Despite its rapid, nondestructive analysis, XRF is not quite sensitive enough. To improve detection limits, the incident intensity must be increased to increase the intensity of X-ray fluorescence, and the background must be reduced. SR meets these requirements with its wide continuous spectrum and high intensity. The intensity of SR is 100-10 000 times that of conventional X-ray sources. It also is linearly polarized. This property can be Used to 'reduce the background: a detector positioned perpendicular to the incident X-ray beam reduces scattering. A monochromatic X-ray of a specified energy can also be separated from SR using a monochromator. The characteristics of monochromatic excitation are as follows: (1) The excitation energy can be designated to be slightly above the absorption edge of a specified element. This increases the sensitivity of measurement for that element. The absence of the unnecessary spectrum reduces the background and improves the S/B ratio. (2) Overlapping peaks can be experimentally separated. Choosing an excitation energy to be between the absorption edges of the elements involved can eliminate the effect of an extraneous element. (3) The strong signals emitted by predominant matrix elements quickly saturates the solid state detector, affecting the detection of trace elements. Setting the excitation energy below the absorption edge of the predominant matrix elements reduces the strong signals. (4) The known spectral characteristics of the exciting X-ray facilitate fundamental calculations and thus help improve the precision.
98 The difference between continuum- and monochromatic excitation is indicated in Fig. 2-16 [ 11]. Twenty ppm of calcium, manganese, and zinc each adsorbed in a chelated resin are used as the sample. Continuum SR, with and without an A1 absorber, and SR monochromatized by a crystal monochromator, are used as the excitation sources. The surface of the silicon crystal used in the monochromator is lapped using SiC. The results clearly show that the use of SR greatly improves the S/B ratio. Of particular note is that much less scattering occurs in the case of monochromatic excitation compared with other methods. Figure 2-17 shows the changes in the spectrum of X-ray fluorescence in relation to changes in the excitation energy using a NIST SRM 612 Glass Wafer (major constituents: SiO2 (72%), CaO (12%), Na20 (14%), and A1203 (2%), plus about 50 lxg g-1 of many other elements) [30]. Figure 2-17a is for excitation by a 19.5 keV X-ray, and Fig.2-17b for a 10.5 keV X-ray. It shows that the latter improves the (a) . . . . . .
":'. 1.0 .1,,,4
=
2.5GeV 105.0mA MAX.CTS_ Ar 1437 ,,.,) C ~ I'Mn ~ Z n
.0
0.5
).5
Ar
0.0 2
4 ' 6 ' 8;' 1'0"1~2' 14 Energy / keV
1.0
05
- MAX.CTS. "_ 2436.0 - ir
4
6
8
10
12
14
Energy / keV
l ZB fi il
~ "~ il Nil ]
0.0 2
4
6
8
10
12
Energy / keV Fig. 2-16. Comparison of fluorescence spectra from a 20 ppm metal adsorbed chelate resin excited using: (a) continuum SR; (b) continuum SR with a 280 ~tm thick A1 absorber; and (c) monochromatized SR. Counting time is 100 s for (a) and (b), and 200 s for (c). From Ref. [11], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
99 (a) .
1.0
.
-
.
t
.
Ca
.
.
.
E~," 19.5 keV t: 500s
SRM (Glass612fer)
I[
Max.CTS.: 6323
![
Sr Zr Nb
scatl
d
0.5 -
l] [[
Si
Rare earth and transition
~Y~ Rbl[ /1 I] l[
Al[I
]l]ll
! "11
0 0
5
10 Energy/keV
15
20
(b) 1.0
Ca
-
_ _
E~," 10.5 keV t" 500 s
SRM 612 (Glass Wafer) Max.CTS.: 31251
m
0.5
Scat.
-
m
[" [--
.
Rare earth and 11 transition /I" [Vi elements I!
o 0
5
10 Energy/keV
15
20
Fig. 2-17. The change in SRXRF spectra from a NIST Standard Reference Material 612 caused by the excitation energy [E?'is 19.5 keV for (a), 10.5 keV for (b)]: t = counting time; Scat. = scattered radiation. From Ref. [30], reprinted by permission of Kodansha, Tokyo.
S/B ratio significantly for elements with absorption edges in the 5-10 keV range, such as rare earth and transition elements. This is because the excitation efficiencies of these elements are increased, and because unnecessary spectrum components which contribute to the background are eliminated.
100 ooo
(a)
800
d
(b)
3000 -
E r " 16.00 keV t :200s
As + Pb
Scat.
Ey" 12.50 keV
2500 -
t
9200 s
AsKs
Scat.
2000 -
600
1500-
. v,.=l r~
400-t
II / PbL~I
AI
A1
1000500 -
0
i
i
i
i
I
0
5
10
15
20
E n e r g y / keV
.it...
O0
"~ 5
_
i
10
i
15
i 20
Energy / keV
Fig. 2-18. Advantage of selective excitation. SRXRF spectra of a sample containing Pb and As caused by excitation energy above the Pb Lin and As K edges (a), and between them (b). Max. counts: 1 296 (a) and 2 330 (b). From Ref. [31], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
Now we will discuss the effect of selective excitation. Figure 2-18 shows the spectra of an A1203 sample containing a 0.1% mixture of As and Pb in a 1:1 molar ratio [31]. The excitation energy is 16.0 keV for Fig. 2-18a, and 12.5 keV for Fig. 2-18b. The K absorption edge of As is at 11.862 keV and the LIII absorption edge of Pb is at 13.038 keV: therefore, if conditions (a) are used the peaks of As Ka (10.53 keV) and Pb La (10.55 keV) overlap. If conditions (b) are used, the excitation energy is set between As K and Pb LIII: hence, no peak appears for Pb La, and the peak of As makes its quantitative analysis possible. The detection limit and accurate quantitative analysis are the most important factors of XRF used for elemental composition analysis (percent) and trace element analysis (ppm, ppb). We will consider these factors below. 2.3.2. Detection limit
Determinants of the detection limit (a) Excitation efficiency and fluorescence yield. When an X-ray irradiates a substance, the X-ray photons excite the atoms of the substance, emitting inner-shell electrons as photoelectrons and creating orbital vacancies. This process of excitation is due to the photoelectric effect. Therefore, the probability of photoelectric absorption (photoelectric effect) is linearly related to the excitation efficiency. This depends on the element and the energy of the incident X-ray. The contribution of photoelectric absorption to total absorption for incident X-ray energies of 10, 30, and 100 keV is shown in Fig. 2-19, which is plotted
101 100
..-
...
80
J ~-60/I /I
I
/I'
:""
/
x : photoelectric absorption. Oc:Comptonscatte ng.
/
f
./" ......
OT:Th~176 scatte~ng" ~: : electron-pair creation.
20
0~
I
20
I
I
40 60 Atomic n u m b e r
I
80
Fig. 2-19. Ratio of total absorption (~t) to photoelectric absorption (x) [32].
using the tables reported by McMaster et al. [32]. This shows that, except for the 100 keV radiation, the total absorption coefficient can be regarded as the excitation efficiency, since most of the absorption coefficient is due to photoelectric absorption. The absorption coefficient's dependence on incident X-ray energy is shown in Fig. 2-20, based on Sasaki's table [33]. The absorption coefficient (excitation efficiency) is highest when the energy is slightly above the absorption edge. The vacancies caused by this excitation are filled by electrons from the outer shells. As shown in Fig. 2-21, the process of filling the vacancies is accompanied by a release of energy, which occurs by one of the following two processes. In the first case, an electron in an outer shell drops to the energy level of a vacancy, emitting an X-ray photon with energy equal to the difference between the two energy levels involved. In the other process, the released energy is transferred to another electron to eject an Auger electron. The ratio of the number of emitted X-ray photons to the number of primary vacancies created is called the fluorescence yield, which depends on the element and the absorption edge. Figure 2-22, plotted using the values tabulated by Bambynek et al. [34], shows the fluorescence yield for the K-series X-ray fluorescence. Elements with small atomic numbers have a low probability of releasing X-ray fluorescence, most of them emitting Auger electrons. In the detection of X-ray fluorescence using the K absorption edge, Ka and K~ lines are emitted. As shown in Table 2-3, the intensity ratios of the Ka to KI~ lines are also element dependent.
102 500 -
7 r
I " absorption edge
~400O C
o300-
91=,,4
O
0
ZrK
o200 0
~lO0r~
d~
<
0-
I
I
0
5
Fe K I
10
Pt LIII
I_ I
15
~ I
20
I
25
Energy / keV Fig. 2-20. Energy dependence of absorption coefficients for Fe, Pt and Zr, plotted as a function of incident X-ray energy [33].
X-Ray fluorescence emission
Auger electron emission (the Auger effect) ctron
2P3/2 2Pl/2 ..... [ O-'---~
2S Ko~1 X-r
ls
i
--O
Fig. 2-21. Energy release mechanism after the X-ray absorption process.
103 1.00.8
Table 2-3 Relative Ko~ line intensities in the K-series
""
Atomic number
9
o0.6-
~
0
.
4
20 24 28 32 36 40 44 48 52 56
-
02
0.0-
I 0
'
I 40
'
I 80
Relative intensity (Kct)
'
0.887 0.883 0.881 0.871 0.856 0.844 0.833 0.824 0.816 0.809
Atomic number Fig. 2-22. Fluorescence yields for K absorption edges [34].
The product of the excitation efficiency, the fluorescence yield, and the ratios of the Ka line represents the intensity of the Ka X-ray fluorescence detected. Calculated values for this product (the fluorescence intensity) are indicated in Fig. 2-23. Since the most suitable excitation energy for the desired measurement can be selected, SRXRF using monochromatic excitation improves the detection limit.
lOO~ 6"
4: . 2-
0 0 0 0r ~ @
_= 1~ ........ 15
I
I
I
I
I
20
25
30
35
40
Atomic number Fig. 2-23. Variation in fluorescence intensity (mass absorption coefficient x fluorescence yield x relative intensity of Kt~ line) with atomic number at 15 keV of the incident X-ray energy. The 15 keV incident X-ray energy is smaller than the binding energies of the electrons in the K shells for atomic numbers above 37.
104
(b) Scattered X-ray and bremsstrahlung. The detection limit is affected to a great extent by the background. The X-ray scattered by the sample contributes greatly to the background. Environmental and biological samples, both the subjects of trace element analysis, are composed mainly of light elements such as carbon and oxygen, and contain very small amount of metals. Much of the radiation intensity from these samples, measured by the energy dispersive method, is the result of scattering caused by light elements. Baryshev et al. [2] and Hanson [35] made thorough studies of scattering by polarized X-rays. In the following we will describe the theory explaining why polarized X-rays reduce the background. There are two classifications of X-ray scattering: coherent scattering and incoherent scattering. The differential cross section of coherent scattering (Thomson scattering) for a free electron is as follows: dtYT = dO
rg.le. ol =
(2-12)
where e 0 is the polarization vector (in the direction of the electric field) of the incident X-ray, e* is the conjugate complex polarization vector of the scattered radiation, and r0 is the classical electron radius. For linear polarization: (d~)
= rZ.sin2O
(2-13)
pol
where ~ is the angle between the direction of polarization of the incident X-rays and the direction of observation. Therefore, the differential cross section of Thomson scattering becomes zero when the direction of observation coincides with the direction of polarization of the incident X-rays. Since the SR obtained using a bending magnet is polarized in the horizontal direction, Thomson scattering can be minimized by positioning the detector perpendicular to the SR beam. On the other hand, for a fully unpolarized X-ray: (d-~o)
= 1 .r~.(l+cos20) unpol 2
(2-14)
where 0 is the angle between the direction of propagation and the direction of observation. Therefore, observation from the perpendicular direction minimizes Thomson scattering also. However, in this case most of the scattering results from electrons bound to atoms rather than from free electrons. This form of Thomson scattering is called Rayleigh scattering. The differential cross section of this scattering in a plane horizontal to a detector is as follows:
105 dO'R)
-d-~/pol
= r~-{f(q, Z)}2.(1 - sin20)
(2-15)
wherefis the atomic scattering factor, q = sin (0/2)/~ is the momentum transfer, and Z is the atomic number. Observation from the perpendicular direction minimizes the scattering. Incoherent scattering is called Compton scattering. The differential cross section of Compton scattering for a polarized X-ray is expressed by Klein-Nishina's formula: dO'c)
= ur 2 .(KK0)2 " (__~+ K
4cos2~ - 2)
(2-16)
where ~ is the angle between incident and scattered photons; K0 = 2rr/2o and K = 2n/~, are the wave numbers of the incident and scattered X-rays, respectively. Using the Compton formula,
K/Ko =
[1 +
a .(1 -
cos0 )]-1
(2-17)
a = Eo/mc 2
(2-18)
where E0 is the incident photon energy. When 0 = ~ = 90 ~ the intensity of the scattered radiation is minimized. For an unpolarized X-ray,
d--~/unpol - -~_
~-0 -- sin20 )
(2-19)
The dependence of the intensity of Compton scattering upon the polarization is indicated in Fig. 2-24 [ 10]. We have previously confirmed that the linear polarization of SR greatly reduces the scattering. However, even though SR is perfectly linearly polarized on an electron's or positron's orbital plane, it contains another polarization component away from the orbital plane. The beam and the window of the detector both have finite size : therefore, Compton scattering cannot be completely eliminated (see Fig. 2-15), although scattering can be minimized by positioning the detector perpendicular to the beam. Compton scattering can be reduced by increasing the distance between the sample and the detector: however, this reduces the solid angle and weakens the signals reaching the detector. Another cause of a background is bremsstrahlung. In the energy region normally used for XRF the sample absorbs most X-rays through the photoelectric effect. The photoelectrons created in this process decay in the sample while emitting continuous X-rays, which also contribute to the background. The energy of a photoelectron ejected from the K shell of an atom by the photoelectric effect is as follows:
106
1.0xl0
-3 0~~89"
// /
0.5•
-3
/
/
/
J
/
/
0=~=90"
5 10 15 E n e r g y / keV
20
Fig. 2-24. Ratio of theoretical difference cross sections for Compton scattering of polarized to unpolarized radiation under scattering angles 0 = ~ = 90 ~ and 0 = ~ = 89 ~ From Ref. [10], reprinted by permission of Amsterdam.
Elsevier Science Publishers
Ex = E I - EK(Z)
B.V.,
(2-20)
where EI is the energy of the incident X-ray and EK(Z) is the energy (work function) required to excite an electron from the K shell up to the continuous energy level. For a sample with a matrix of an element of atomic number Z, if Nx photons with energy between Ex and Ex + dEx are emitted [36], Nx = 2.5•
10-6.Z.Ni.cYip.t ~ X "(Ez9
Ex)
(2-21)
where NI is the number of incident photons, t is the thickness of the sample (g cm-2), and crw is the photoelectric absorption cross section of the incident X-ray. The distribution of the bremsstrahlung for a 10 keV X-ray with a carbon matrix is shown in Fig. 2-25, which is calculated from Eq. (2-21).
107 1.0 0.8 .~..~ r,r
~
I=
"
"~0.4 r~
o.2 0.0 0
2
4
6
Energy / keV
8
10
Fig. 2-25. Calculated bremsstrahlung intensity versus its energy in a carbon matrix using a 10 keV incident X-ray energy [36].
Calculated values of the detection limit It is important in SRXRF to estimate the detection limit correctly. The detection limit is commonly defined as the minimum concentration or absolute amount, of an element in a sample, which can be detected with a confidence level of above 90%. Gordon [12] calculated this theoretically. His calculations are based on the parameters of the NSLS, a 2.5 GeV ring. He considered two kinds of samples. One contained a carbon matrix, as an example of a bioorganic substance, and the other a mineral sample containing nine kinds of elements. Both samples were assumed to be attached to a carbon-matrix substrate of 1 mg cm -2 (e.g., a Kapton film). Both the energy dispersive and wavelength dispersive methods were considered. In the energy dispersive method a Si(Li) detector with a 30 mm 2 crystal area was assumed to be used, and in the wavelength dispersive method a multi-channel crystal spectrometer system. To calculate the detection limit, Gordon used the following formula: CD(ppb) = N x 109 / (I (7 T G A)
(2-22)
where: N is the detectable signal, I is the integrated beam intensity, cr is the cross section in cm 2 g-l, T is the sample thickness in g c m -2, G is the fraction of the solid angle subtended by the detector, and A is the self-absorption correction.
108 From the criteria of Currie [37], N is equal to 3.29(nNbg)a/2 (Nbg is the background beneath the signal; 1 -< n --<2). In this calculation, Gordon took the size of the detector and the distance from the sample into consideration. He also calculated the detection limit for the photon fluxes, further increased at higher energies by using a 6-pole wiggler. Figure 2-26 shows Gordon's calculations of the determination (quantitation) limits for the carbon matrix sample measured by the energy dispersive method. The determination limit (CQ) was obtained from the detection limit (CD) using CQ/CD=I0f/3.29, wherefis a correction coefficient for the amount of background. The distance from the sample to the detector is 10 cm. The value (CQ) is for a one-minute measurement. The detection limit (Co) is from a third to a fifth of this value. 3
10
i
i
i
i
Ktx
9
l
i
LO~
~- ld 30 keV
t\
0 eV,
"~ 101
,
15 keV v
~o 10 0 .~ "~
0keV
!~~,~~3 keV \ -11 10 10
N \20keV
10keY 15 keY
1
I
I
I
I
20
30
40
50
t
60
t
70
80
Atomic number Fig. 2-26. Determination limits for 2 mg cm -2 carbon matrix sample using a Si (Li) detector and a one-minute measurement. Sensitivity curves are shown for five excitation energies ranging from 5 to 30 keV. The sensitivity expressed is a determination limit (concentration measurements) with a 10% standard deviation attributed to counting statistical errors. The detection limits are a factor of 3 to 5 lower than the determination limits shown here. From Ref. [12], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
109 Experimental values of the detection limit
Starting in the 1980s, XRF experiments were conducted at various SR facilities, and the detection limit studied experimentally. Gilfrich et al. [7] made their experiments at SPEAR of SSRL. The beamline they used was not equipped with a mirror or a monochromator. It produced a non-monochromatic beam with 1 mrad divergence in the horizontal direction. The X-ray energy ranged from 2 to 60 keV. The experiments were carried out using the energy dispersive method and the wavelength dispersive method employing a fiat crystal. A vacuum deposit of metal on a Mylar film, and a solution dropped on a Millipore filter were used as samples. The X-rays were obtained using a 3 GeV ring with a storage ring beam current of 40-80 mA. The energy dispersive method allowed a 100-s measurement using a 2.4 • 10-4cm 2 incident beam size. The wavelength dispersive method employed a 0.4 cm 2 beam (100-s measurements). It used LiF and PET as analyzer crystals and a proportional counter as the detector. All the samples measured were very thin. The detection limit was assumed to be three times the standard deviation of the background (Fig. 2-27). The energy dispersive method gave a detection limit of the order of 10-12 g in absolute amount.
::i. ..
100
!
|
!
(a) Energy -1 dispersion 10
o ,~ o o
-2 10
m
10.3
i
/ /)/
K-lines I
20
I
I
40
i
i
_
10~ (b) . . . . Wavelength/ 10 -1 - d i s p e r s i i ~
_
10 -2
l
- - - - On filter On Mylar
-
L-lines I
I
60
Atomic number
I
I
80
10-3
~K .i
20
--~'--O'n filter On Mylar j ~ A 1
lines ~ n e s n
n
40
n
i
60
.
,
80
Atomic number
Fig. 2-27. Detection limits as a function of atomic number as measured by (a) energy dispersion and (b) wavelength dispersion. From Ref. [7], reprinted by permission of the American Chemical Society, Washington, D. C.
110 Also at SPEAR, Giauque et al. [38] studied the dependence of the detection limit on the excitation energy, taking advantage of the fact that monochromatic excitation can be set to any level. They reported that, under optimum conditions, they obtained a detection limit of 20 ppb for many elements. Bos et al. [ 10] compared SRXRF detection limits with those of conventional XRF and an analytical technique using proton excitation (proton induced X-ray emission spectrometry: PIXE). The conventional X-ray source used a Mo anode and Zr, Mo, and Ti filters. This source produced a 17.5 keV X-ray at 26 kV and 12 mA. For proton excitation, they used 3 MeV protons produced using a cyclotron. In the SR experiment, they used X-rays of 16.5 keV and 9.1 keV in beamline 7 at the SRS of Daresbury incorporating a pyrolytic graphite crystal monochromator. Measurements were conducted using NIST Orchard Leaves (SRM 1571) and Human Hair (IAEA-HH1). The detection limits obtained for each sample are shown in Fig. 2-28. The calculation was based on the criteria of Currie [37]. Measurements were made for 1 000 s at 2 GeV with a beam current of 200 mA. Compared with conventional XRF, SRXRF substantially improved the detection limits. It was found that SRXRF is nearly equivalent to PIXE up to Z = 30, and has an advantage for heavier elements. Specifically, the detection limit can be improved further because this method allows the user to set the excitation energy to any desired value (see the results using 9.1 keV in Fig. 2-28). They also studied how the V K~ X-ray arising from the 9.1 keV X-ray changed, depending on the sample thickness (Fig. 2-29). The results indicated that the detection limit is very sensitive to sample thickness when the sample is thin. Hanson et al. [8] performed their experiments at CHESS. This ring has an electron energy of 5 GeV and generates strong SR in the hard X-ray region. They used a channel-cut silicon monochromator, and chose the same sample that Bos et al. [10] used (SRM 1571). X-Rays of 13.0, 16.25 and 24.9 keV were used as incident beams. The detection limits were calculated using the criteria of Currie [37] (Fig. 2-30). The present authors performed a similar experiment at the Photon Factory. Using a 2.5 GeV ring with a storage ring beam current of about 200 mA, we measured several types of NIST standard reference materials. Powder samples were applied thinly to adhesive tape. The measured spectra of Bituminous Coal (SRM 1632a), Oyster Tissue (SRM 1566), Orchard Leaves (SRM 1571), Citrus Leaves (SRM 1572), and Aluminum-Silicon Alloy (SRM 87a) are shown in Fig. 2-31. A Si (111) double-crystal monochromator was used, with a 15 keV exciting X-ray. The X-ray fluorescence measuring device was developed by Iida et al., and the measurement time was 500 s. The sample and the Si(Li) detector were 45 mm apart. The size of the beam's cross section is shown in the figure. The cross section was changed so that the detector would not be saturated under the same geometrical conditions. The measurement was made under vacuum. The detection limits calculated based on the criteria of Currie [37] are given in Table 2-4 and in Fig. 2-32. Organic and alloy samples were found to have quite different detection limits. This is due to the different matrices of the samples. Even among organic samples, different compositions give different detection limits. Measurements of Citrus Leaves and of Aluminum-Silicon Alloy using an X-ray tube are shown in Fig. 2-33.
111 3-
10
7
e~o
(a)
102
o 1
10
l
o
10
10
0
7
e~
SRXRF (E?= 9.1
I
-1
3
102
-
I
20
10
10
i [IET = 16.5 keV)
,[
30
40
(b)
-SRXRF
(ET = 16.5
O
o~
O o
~
10
10
0 -
-1
10
PIXE
-
SE,RXRF1 k ,V " ~ ~ ( T = 9.1 keV) ~
.,
, -. _~
I
!I
i
I
20
I ~"~-
30
,
40
A t o m i c number Fig. 2-28. Detection limits of several elements in, (a) NIST Orchard Leaves, and (b) IAEA Human Hair, for different excitation modes. From Ref. [10], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
112
A
-
3000 ~
/
~
X
X
2 GeV, 130 mA
/
o 2000
-0.03
1000 s
/
E~,= 9.1 keV -
1000 I - d
1,7 1,1
0
~:It:x_____
.
.
.
.
.
.
b) I
I
10
i
20
-
30
Thickness (mg c m
i
40
0.04
I
Z
0.02 k~ 0.01
"~
50
-2)
Fig. 2-29. Number of V K~ counts of samples with well defined thickness. Curve b shows the root of the number in the background beneath the peak normalized to the .peak content (proportional to the detection limit). From Ref. [10], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
3
I0
I
I
I
I
+ 13.0 keV x 16.25 k e V -
It
§
~.~
1
' 24.9 keV
§
9~ lO -
s 9
0
§247
It e
N
m NIlI
9
++
~
x
Ig Ig
...b
lo -~-2
10
I
10
16
I
I
22
28
I
34
40
Atomic number
Fig. 2-30. Detection limits of several elements in NIST Orchard Leaves when fluoresced with 13.0, 16.25 and 24.9 keV X-rays [8]. (Reprinted with permission from A.L. Hanson, H.W. Kraner, K.W. Jones, B.M. Gordon, R.E. Mills and J.R. Chen, "Trace Element Measurements with Synchrotron Radiation", IEEE Trans. Nucl. Sci., NS-30, 1339 (1983). 9 IEEE.)
113 5
10 t 04
(a) SRM 1632a (Bituminous Coal) Fe " Ti+V ^ ,,. K+Ca I /~Fe
1
~"
"
[(vkI ~~.'s ls
o~
o' 1 o
I 0
5
10 10 r~
0
/~h"
.JVi
Br
~
1
1
AY
Zn
,,,I,I /I
B.S.: 2.2 x 3.0 mm I 5
I 10
Energy / keV
I 15
.dJ._
_ll ......
I
20
(b) SRM 1566 (Oyster Tissue) Zn
4 -
K p , SCI ~ ~Ca
1 03 -
Scat. As+Pb
Fe
~ L
Br
10 2 I ..I]
1
10 o
MAX.CTS:7337 B.S.: 2.2x 3.0 mm2
10 -
I 5
0 5
10 -
(c)
1 02 -
K A Ca pS
1
10 -i 0
LLL_JtU,"ll=l...
I
20
Scat.
fV~Ca
Fe
~MA
10 o
I 15
SRM 1571 (Orchard Leaves)
10 1 0z -
I 10
Energy / keV
4
r~
I
.CTS..
10 10
EL~
Scat. /~
I~ll
Mn
Pb+As Fe
Zn
Br
X. B.S.: 1.5X2.9 mm2
/l_d.I 1 ~
I
I
I
I
5
10
15
20
Energy / keV
Fig. 2-31. SRXRF spectra from NIST Standard Reference Materials under vacuum. Excitation energy, 15 keV; counting time, 500 s; MAX. CTS, maximum counts; B.S., beam size; Scat., scattered radiation. Except for SRM 87a, thin samples were attached to adhesive tape: SRM 87a was used as it was.
114
10 10 :"4. r.~
1
5
-
4
SRM 1572 (Citrus Leaves)
B.S.: 0.7 X 0.4 mm
p~ICa
-
As+Pb
S
2
MAX.CTS" 4108
Ca
-
03
10
(d)
-
Mn
Fe
Cu
t~
2
Scat.
13r
Zn
Pb
1
10 10
0
0
I
I
10
15
..........
t
|
I
20
Energy / keV 5
10 "] 1 04 i...i 9 r,r
3
(e) SRM 87a (A1-Si Alloy)
1
10"]
Zn Fe Ni Cu Zn Ga/1 Mn,~e ~ \ ~ ~ 77APb
A1,Si
02
Pb
Scat. ~
9
101 10
o
I"
I
0
I
I
I
5
10
15
.....
~
I
20
Energy / keV Fig. 2-31. SRXRF spectra from NIST Standard Reference Materials under vacuum. continued Table 2-4 Detection limits in ppm (l.tg g - l ) obtained by the measurements of NIST SRMs at the Photon Factory on Beamline 4A Element Ti Cr Mn Fe Co Ni Cu Zn
SRM 1632a SRM 1566 SRM 1571 SRM 1572 SRM 87a (Bituminous Coal) (Oyster Tissue) (Orchard Leaves) (Citrus Leaves) (Al-Si Alloy) 60 m ~ 30 . 9 5 4
m -10 5 .
m 4 5 3 .
~ 4 3
.
2 1 1
.
m ~ 7 6
800 350 260 140
3 3 2
70 60 60
Measuring conditions are described in Fig. 2-31. Detection limits are calculated on the basis of the Currie criteria [37].
115
1000 _
[] Bituminous 9 Coal zx Oyster 9 Tissue 9 "Orchard Leaves O "Citrus Leaves x 9AI-Si Alloy
~......,~
o
~
~
~:~ 1 0 0 ..r
@
10-
0.1
I
20
I
22
I
24
!
26
I
28
I
30
I
32
Atomic number Fig. 2-32. Detection limits for NIST SRMs, derived from the spectra shown in Fig. 2-31 on the basis of Currie's criteria [37].
The measurements were made under vacuum, using a Mo anode of 40 kV and 20 mA, and a Mo secondary target. Measurement times were 1 000 s for Citrus Leaves and 500 s for the Alloy. Compared with measurements employing SRXRF, there is a clear difference in the background level. The detection limits of Orchard Leaves obtained from the experiments of Hanson et al. [8], Bos et al. [10] and ourselves are listed in Table 2-5. Each used a different ring, optical system, excitation energy, and sample thickness; yet the results all agree within 1 ppm. Iida et al. [ 11, 20], at the Photon Factory, studied the variation in the detection limits with the excitation mode. The samples used were 0-100 ppm of Zn, Mn, and Ca, adsorbed in a chelate resin, attached to adhesive tape. X-Ray fluorescence was measured by the energy dispersive method to allow calculation of the detection limits, using a white (nonmonochromatic) beam; an aluminum absorber only; a single-crystal monochromator using a silicon crystal surface lapped with SiC; a wide band-pass monochromator using a total reflection mirror and an aluminum absorber; and a wide band-pass monochromator using a total reflection mirror and a transmission mirror. The results are shown in Table 2-6. The strong intensity of white (non-monochromatic) excitation gives a low detection limit, in absolute amount. Using an absorber improves the detection limit for Zn, in relative
116 concentration. This is because scattering in the high energy region is reduced. The crystal monochromator gives the best detection limit in relative concentration since it reduces the background caused by scattering. The wide band-pass monochromator exhibits excellent performance in both relative concentration and absolute amount.
sRM1572
U' [ ~,
, t
(Citrus Leaves)
] 103~-
I , Scat. I A I
t~a Ca
10
'1
TM
.
1
.
.
I
5
. . . .
I
. . . .
10
I
.
.
.
.
15
1
sRMZTa
04
_/ 103~102
I
(Al-Si Alloy)
, Scat. I /~ 'l
Ni b tb
l,Si TiCr~
10
ii
20
1
5
10
15
20
Energy / keV
Energy / keV
Fig. 2-33. Spectra of NIST SRMs by XRF using a conventional secondary target (Mo) energy dispersive system, measured with a Mo tube, 40 kV, 20 mA, 1 000 s. The samples are those used in Fig. 2-32.
Table 2-5 Comparison of detection limits (ppm) of four elements in NIST Orchard Leaves (SRM 1571) by three different workers Element Mn Fe Cu Zn
Hanson et al. [8] a 4 2 0.6 0.5
a CHESS: 5.144 GeV, b SRS" 2 GeV, c PF: 2.5 GeV,
Bos et al. [10] b 2 2 0.6 0.5
16.25 keV, 16.5 keV, 15 keV,
300 s. 1000 s. 500 s.
Authors c 5 3 1 1
117 Table 2-6 Comparison of detection limitsa(DLs) for different excitation modes [11, 20] Excitation mode
DL in relative concentration
Irradiation area/ mm 2
DL in absolute amount Zn/pg
Zn(ppb) Mn(ppb) Ca(ppb) Continuum
550
410
440
3.5 x 10-3
0.13
Continuum 170 with absorber b Crystal 60 monochromator Mirror/absorber b 430
240
750
2.8 x 10- 2
0.34
70
200
1.1
4.7
180
410
1.1 x 10-2
0.33
Reflection/ 100 transmission(soap)
140
470
4.2 x 10-3
0.03
a The definition of the DL was a signal at least three times the square root of the background criterion. The counting time was 100 s. b A1 of 280 mm in thickness was used.
2.3.3.
Calibration
Calibration is performed in basically the same way as when calibrating conventional XRF. However, monochromatic excitation and collimation further facilitate calibration calculations. The results of an experiment on thin samples of several elements, performed by Kntchel et al. [39] using DORIS at HASYLAB are shown in Fig. 2-34. The results show excellent linearity. When using monochromatic excitation, the quantity of an element can be determined from the quantitative analysis value of another element using an X-ray fluorescence cross section.
Table 2-7 Calculated contents of several analyte elements in NIST Orchard Leaves (SRM 1571) using the known content of Fe (300 ppm) from the data shown in Fig. 2-23 Element K Ca Cr Mn Ni Cu Zn
Calculated values
Certified values
0.5% 0.9% 2.6 ppm 46 ppm 0.8 ppm 12 ppm 24 ppm
1.47% 2.1% 2.6 ppm 91 ppm 1.3 ppm 12 ppm 25 ppm
118
An example of determining the concentration of elements, based on the quantitative analysis value for iron, is shown in Table 2-7. SRXRF is also useful when using the fundamental parameters method, since it produces monochromatic incident X-rays and high collimation.
lO3 102
G 101
n
m
10~ 10-1 ,.,
10~ ~
..... 10I ~
1(~2
1~)3
Concentration (Bg g-1) Fig. 2-34. Calibration plots : (A) chromium; (m) arsenic (• 1.50); (0) yttrium; ( , ) molybdenum (• 0.75); (O) cesium (x 0.50): Co is the ratio of the counting rate to the standard. From Ref. [39], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
2.3.4. A d v a n t a g e s
and d r a w b a c k s
We would add two more to the many advantages of SRXRF we have already described. First, because of its high sensitivity, this method can be used in the analysis of lower concentrations, using smaller samples, than conventional XRF. The X-ray fluorescence spectrum of a strand of hair is shown in Fig. 2-35. Even a small amount of sample can provide a spectrum with a satisfactory S/B ratio. This suggests that SRXRF is suitable for microbeam analysis. Another advantage is that SRXRF causes far less radiation damage to samples than methods such as PIXE which use charged particles as the excitation source. It is reported that the beam does more than 102 of the damage to blood cells caused by photon excitation [40]. We will now discuss the drawbacks of the present SRXRF technique. The SRXRF analysis of two kinds of aluminum alloys was compared with chemical analysis and glow discharge mass spectrometry of the same samples. We attempted to determine sample B, based on the quantitative analysis value (chemical analysis value) of sample A. The results are shown in Table 2-8 [31]. The detection limits for trace element analysis of metals show that SRXRF has no advantage over the other methods. Even with SR excitation, it is difficult to reduce the
119 spectral background below the lag g-1 level for many industrial materials containing elements with high atomic numbers. Attention should be paid to the effect of diffraction caused by the sample. Sutton et al. [41] discussed the effect of diffraction in continuum radiation. We will describe this same problem due to diffraction that we experienced when using monochromatic excitation [31]. We used the highly pure aluminum employed in VLSIs as a sample. The sample was cut from a block of material, using a superhard steel cutter, while dripping alcohol, and degreased. It is known that this sample contained about 80 ppb of U and Th. A preliminary XRF
(a) 1000
MAX.CTS: 2379 Cu
Scat.
.s..
~o 100
N
A /~
lO i .
1 -! o
I
I
5
.1..... I__
I
10
I
15
20
Energy / keV ,=
(b)
,=
ooo
s
-
MAX.CTS: 1068
.
.I==4 r~
Scat.
Br
Zn
,=
~
100-!..
N
-
Ar Ca
Fe
Br
Cu Zn Pb
lO. ,=
1
-
0
I
5
I
10
I
15
I
20
Energy / keV Fig. 2-35. SRXRF spectra of a strand of human hair (male)" (a), white part; (b), black part. Excitation energy, 16 keV; counting time, 1 000 s.
120 Table 2-8 Analytical results for two aluminum alloys obtained by three different methods Element
Cr Cu Fe Mn Zn Th(ppm) U(ppm)
Chemical analysis a (%)
GDMS b (%)
Sample A
Sample B
Sample A
Sample B
0.059 0.0073 0.11 0.060 0.018
0.0005 0.0009 0.11 0.0030 0.0050
0.062 0.007 0.12 0.068 0.018
<0.001 0.001 0.14 0.003 0.005
0.06 0.38
0.06 0.18
0.07 0.33
0.07 0.15
SRXRF (%) Sample B c
0.01 0.001 0.10 0.002 0.004 Not detected Not detected
a U was analyzed by fluorophotometry, Th by colorimetry and other elements by inductively coupled plasma atomic emission spectrometry. b GDMS is glow discharge mass spectrometry. c SRXRF analysis values of sample B are calculated on the basis of the chemical analysis values of sample A and the SRXRF measurement values of both samples. From Ref. [31], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
measurement gave the amounts of U and Th shown in Fig. 2-36a. However, neither element was detected in the final measurement (Fig. 2-36b). Since we thought that the peaks that appeared in the preliminary test were caused by X-rays diffracted by the sample, we changed the incident angle slightly. This changed the spectrum in the 12-15 keV region, confirming that the results obtained in the preliminary test were incorrect. When we measured silicon containing a small amount of U, a diffraction peak appeared near the U Lo~ peak, as shown in Fig. 2-36c. Transition metals were also detected in this sample. These could have contaminated the sample when it was being prepared. After washing the sample with acid, only a small amount of iron was detected, as shown in Fig. 2-36d. Special attention must be paid to these problems, since the peaks from diffraction and contaminants on the sample surface might overlap the data used for analysis. Another problem with SRXRF is the increase in background due to resonant Raman scattering, as pointed out by Jaklevic et al. [42]. We have repeatedly maintained that when monochromatic excitation is employed, the energy of the incident X-ray can be set to any appropriate value to maximize efficiency. In addition, for an element with a large atomic number, the background can be reduced by setting the energy of incident radiation just below the absorption edge of that element. However, Jaklevic et al. [42] suggested that this was not always true. They suggested that setting the excitation energy just below the absorption edge of a matrix material caused resonant Raman scattering, and increased the background. Raman
121
scattering is a continuous spectrum with a cutoff in the high energy region. At SSRL, they studied Cu in GaAs. The X-ray fluorescence was measured with incidences of 9.2, 9.8, 10.0 keV. The absorption edge of Ga is at 10.37 keV. The intensity of resonant Raman scattering, which changes with the sum of Rayleigh and Compton scattering, was found to increase as the
1.0,
"~ ~" (a) ,~d [
,
I
'
I
,
I
,
9
L
9
9
"1
(?)
, E~ 22.70keV
OI i,,
11
(b)
?"~
|
Th Ltx ET. 20.50 keV (9) U L o ~ t:2000s
,
I
,
13 15 Energy / keV . . . . ET: 19.60 keV t : 2000s Fe
=
17
Ey. 22.70 keV
~
t:2,00s
0
~ !f,~#
Fe
.,./v
It
Th Ltx I J IU Lo~.f"-
~k%...TiCr~Fe ^ / ] , Ni
,, ]~,,.[
1~,!
/J t: 200 s
~
5
,
'i~| "1
,
10 15 20 Energy / keV
25
1.(l
~(d
E7:. 19.60 keY t: 1000 s
Th La
I k T Cr/! Fe
,
[ /
I U L a t'1 ~ 0
Fe
,
~ ,~ "~
Ey. 19.60 keV 3
5
t'2000s 7 9
0 11
13
15
2
4
6
8 10 12 14 16 18 20 Energy / keV
Energy / keV Fig. 2-36. SRXRF spectra of high-purity aluminum (a, b and d) and silicon (c). (a) Preliminary; (b) at two different tilt angles using the same sample as in (a); (c) at two different tilt angles of silicon containing a trace amount of U; and (d) after surface cleaning of the sample, following the measurement of (b). From Ref. [31 ], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
122 incident energy gets closer to the absorption edge. The ratio of the peak areas of resonant Raman scattering and Rayleigh-Compton scattering was found to be 2.3 at an incidence of 10 keV, and 0.64 at an incidence of 9.2 keV. The detection limit for Cu was 1 ppm at an incidence of 10 keV, and 0.6 ppm at an incidence of 9.2 keV. The same workers compared this GaAs sample with a cellulose matrix sample and found that the background for Cu was 12.9 times larger than for cellulose at 10 keV, and 4 times larger at 9.2 keV. 2.4. E L E M E N T A L ANALYSIS BY TOTAL R E F L E C T I O N XRF 2.4.1. Total reflection method
The detection limit in XRF is improved by a greater signal intensity and lower background. To reduce the background in the energy dispersive method, it is necessary to reduce the scattering caused by the sample and the sample holder, and to keep down bremsstrahlung. We saw in Section 2.3.2. that polarized SR greatly reduces the background. In ordinary XRF, the sample supports should be as thin as possible. Various micrometer-thick materials, such as Mylar films and Kapton films, are used depending on the purpose of the analysis. To further reduce the background, XRF can use the total reflection of X-rays. As will be described in Section 2.4.2. if an X-ray is totally reflected by a surface, it hardly penetrates the substance. Therefore, attaching the sample to an optically fiat surface (reflector) keeps the scattering caused by the sample holder to a minimum, thereby improving the detection limit. Yoneda and Horiuchi [ 15] were the first to demonstrate the effectiveness of this method, using an X-ray tube (W target, 35 kV, 15 mA) and the energy dispersive method. A glancing angle was adjusted to be much lower than the critical angle, to achieve nearly 100% reflectivity. Detection limits of the order of ng were achieved for Cr, Fe, Ni and Zn. They also reported that this method eliminates the matrix effect and facilitates calibration. Experiments employing the total reflection method were made later using an X-ray tube or a rotating anode, and have become very popular, particularly in recent years [ 13, 14]. Analysis in the pg range is now performed routinely. Today, total reflection XRF spectrometers for silicon wafers take advantage of the nondestructive, highly sensitive, simultaneous multielement analysis method. These spectrometers, equipped with an automatic measurement device, are used to measure trace quantities of metal contaminants on the surface of silicon wafers, and make it possible to map them with a detection limit of 108-1010 atoms cm -a. An advantage of these units is that they can be installed "in-line" at semiconductor plants. In the laboratory, total reflection X-ray fluorescence (TXRF) spectrometry is mainly used for highly sensitive detection of impurities in solution, which may be dropped on a reflector and dried, or for the analysis of contaminants on silicon surfaces. However, most problems concerning calibration have yet to be solved. Iida et al. [16] thoroughly investigated the SR method at the Photon Factory. The advantages of using SR for TXRF are as follows: (1) Monochromatic excitation can be used to improve the S/B ratio.
123 (2) The excellent collimation of SR is suitable for total reflection experiments using grazing incident beams applied at small glancing angles. (3) The linearly-polarized beam further reduces the background. (4) Selective excitation improves the detection limit. Thus, SR is the most suitable excitation source for TXRF. 2.4.2. The principles of the total reflection method
As discussed in Section 2.2.1., the refractive index of X-rays is very slightly smaller than unity. Therefore, a highly collimated X-ray beam applied to a fiat surface at an angle smaller than the critical angle is totally reflected. Such a beam penetrates the sample only slightly, and the reflectivity of the X-ray is independent of its polarization. Under these grazing incidence conditions, the reflectivity R can be expressed as follows, using Fresnel's formula [43]: Ar ]2=
R=lAi
01- 02 '12 01+02
(2-23)
I
where Ai and Ar are the electric field amplitudes of the incident and reflected X-rays, respectively, and 01 and 02 are the respective glancing angles, as shown in Fig. 2-37. Generally, 02 is a complex number, described as follows using the complex index of refraction. 02 = ( 0 7 -
2~-
(2-24)
i 2fl2) 1/2 = P2 + i q2
p2 = 1 {[(01 - 262) 2 + 4/~] 1/2 + ( 0 2 _ 262)}
(2-25)
q22 = 1 {[(01 -- 2 ~ ) 2 + 4]322]1/2 - (0 2 - 2~)}
(2-26)
The values $2 and t2 are those indicated in Eqs.(2-2) and (2-3) for the reflector. The amplitude of the transmitted (refracted) X-ray is attenuated in the z direction. The depth at which the X-ray intensity attenuates to 1/e is given by Zp(O1) = 1
2k l.q2
=
~,
.[{ (0 2 _ 262)2+ 4132} 1/2 _ (0 2 _ 262)1-
1/2
(2-27)
2"~
where ~ is the wavelength of the incident X-ray, and kl=2n/A. The results of the calculation of the reflectivity and penetration depth (Zp) for silicon near the critical angle are given in Fig. 2-38. The wavelength of the X-ray is 1.24 A. For glancing angles smaller than the critical angle, the penetration depth of the X-ray is very small (a few tens of A). There is a standing wave on the surface of the sample due to the interference of the incident and reflected X-rays. The intensity of the X-ray on the surface of the sample is given by
124 Medium 1 (n l )
Medium 2 (n 2 ) Z
Fig. 2-37. Schematic drawing of X-rays when incident X-rays from air or vacuum (n1-1) irradiate the surface of a material having refractive index n2.
1.0-
.:-10
0.8-
-10
5
4
"~-06.~ 9
l,io
-10 ~0.4-
3
O
=
-lO
0.2-
2
>o
=,
0.0 0
I
2
I
4
I
6
Glancing angle / mrad
I
8
lO
1
10
Fig. 2-38. The calculated glancing angle dependence of reflectivity and penetration depth for a silicon wafer using an incident X-ray with a 1.24/~ wavelength.
125 M(O1) = 4 O ? / { ( O1 +p2)2 + q2}
(2-28)
Calculation of this value for silicon gives the results shown in Fig. 2-39 9 The product of the intensity on the surface and the depth of penetration of the X-ray gives the intensity distribution of the X-ray fluorescence emitted by the substrate shown in Fig. 2-40. At a glancing angle smaller than the critical angle the intensity of X-ray fluorescence is very close to zero. The scattered X-rays are caused by X-rays that go into the substrate without being reflected. Therefore, the closer the reflectivity is to unity, the less is the scattering 9 The condition of the surface of the substrate affects its reflectivity. A rough surface reduces the reflectivity, and thus increases the intensity of the emitted scattering and X-ray fluorescence. Surface roughness can be described using a group of fiat planes distributed in a Gaussian manner. Taking the standard deviation of the Gaussian distribution as tr, the reflectivity is given by R = Ro-exp[ - (4 11;010"/~)2]
(2-29)
where Ro is the reflectivity for a surface with no roughness. The reflection curve for a (r = 10 /~ is shown in Fig. 2-41 a. The corresponding X-ray fluorescence intensity is shown in Fig. 24lb. The angular dependence of the intensity of X-ray fluorescence when a sample is spread very thinly on a substrate was calculated by Iida et al. [16] and is shown in Fig. 2-42a (tr is hereafter assumed to be zero, unless otherwise noted). The intensity is about twice as large above the critical angle as below it. The intensity of the X-ray fluorescence emitted from the 4 m
1.0--"
=0.8"~0.6-
~2-
9~,.,.,,I
r~ = 0.4-
r~
~_~ 0.2-
00
I
2
I
4
I
6
I
8
G l a n c i n g angle / m r a d
I
10
Fig. 2-39. The calculated X-ray intensities on the silicon surface (perfect surface; tr= 0) as a function of glancing angles, using a 10 keV incident X-ray.
0.0-
0
I
2
I
4
I
6
I
8
I
10
G l a n c i n g angle / m r a d Fig. 2-40. The calculated X-ray fluorescence intensities from a silicon substrate ( a = 0) as a function of glancing angles, using a 10 keV incident X-ray.
126
"-:'.1.00.8-
(b)
, - , 0 8. -
.1,.=1
t~
"-06-
9- 0 . 6 -
0 0
O
0 L)
00.4-
~0.4O
0.2-
r
0.2-
c~
0.0-
I
I
0
2
~I~ -
I
4
I
6
~0.0
I
8
10
!
0
Glancing angle / mrad
J
I
2
I
I
4
I
6
I
8
10
Glancing angle / mrad
Fig. 2-41. The glancing angle dependence of reflection from a silicon surface (a); and the X-ray fluorescence intensities from a silicon substrate (b). Surface roughness, 10/~; incident X-ray energy, 10 keV.
(a) .1,.-I
-
(b) Sample
/
.
o
O
f
/ f J
9i,..,.I
O
f
/
-
/
/
/
.
/
-
!
-
-
I. . . .
~'I
I Reflector )I 1
B
I
!
0
,
I
I I
2
Normalized glancing angle (0/0c)
s
1
~
I
2
3
=
I
4
=
I
,
5
Glancing angle / mrad
Fig. 2-42. (a) Calculated intensities of the signals from the sample (solid line) and from the reflector (broken line) as a function of glancing angles. (b) Angular dependence of the Zn ( 9 ) and Si (o) fluorescence signals, which are from the sample and the reflector, respectively. From Ref. [16], reprinted by permission of the American Chemical Society, Washington, D. C.
127
(a) 1.0
(b)
-2"5MGeA~lgr
:lA50
2.5 GeV 133.9 mA | MAX. CTS. :651 ~Zn
1.0
I Zn
0.5
!i Sca'"
0.5 si
i
II
0.0
0.0 I
2
I
I
4
I
I
6
I
I
I
8
I
10
Energy / keV
I
I
12
2
4
6
8
10
12
Energy / keV
Fig. 2-43. Spectra (a) and (b) obtained at different glancing angles, corresponding to A and B in Fig. 2-42, respectively. From Ref. [16], reprinted by permission of the American Chemical Society, Washington, D. C.
substrate shows an S/B ratio which greatly improves below the critical angle. The results of the experiment by Iida et al. [16] are shown in Fig. 2-42b. A sample of 2 lal of a Zn solution was used, dried on an optically flat reflector. The intensity of X-ray fluorescence for Zn and Si is indicated in Fig. 2-42b. The measured values agree well with the calculated values. When the spectrum was measured near the critical angle shown in Fig. 2-43 [ 16], there was very little scattering below the critical angle. The beam width was a few tens of ILtm.
2.4.3. Liquid sample analysis Figure 2-44a [31 ] shows the spectrum of a solution containing 1 ~tg m1-1 each of V, Fe, Ni, Zn, and Pb dried on a fused quartz reflector, measured by the total reflection method at the Photon Factory. The XRF spectrum of the same solution dried on filter paper is shown in Fig. 2-44b [31 ]. The experiment was conducted using Beamline 4A and equipment developed by Iida et al. The horizontal axis of rotation of the sample holder makes this device suitable for SR experiments. Measurements are made in the air using a 14 keV monochromatic X-ray obtained from a Si(ll 1) double-crystal monochromator. It is evident that using the total reflection method produces very little scattering and improves the S/B ratio. Similar experiments on Ti, Mn, Cu, and Ge were carded out. The detection limits obtained are indicated in Table 2-9 [30]. In the total reflection method, any absorption and secondary excitation in the sample is negligible because the sample is very thin. We applied TXRF to a synthetic sample from 100 ~tl of a solution containing 50 ng g-1 of V, Cr, Mn, Fe, Ni, Cu and Zn, dried on a silicon
128 wafer (Fig. 2-45). The intensity corrected for air absorption, excitation efficiency, relative Ko~ line intensity and fluorescence yield is shown in Fig. 2-46. This shows that a fixed amount of sample gives a constant X-ray fluorescence intensity, within the experimental error. Therefore, we can ignore the matrix effect and secondary excitation.
1.0
~=s" tET' "20014. : lilLl 0s it _a) Total Reflection Zn
~, ~ /,,' ~,."
keVFe
~U.3" k
,!1, il ,
i!t
I 0
"
0
Scat,
i,~!t ~'-" '
2
4
6
"
8
Analysis
tE"T'5~'0keY
Scat!
I ,i
i~t! " "
I .~~
(b)
o
i,/ :
Ni '
10 12 14
0
.*~~.
1
3
~"~"'.-"'~
5
7
9
.
11
'
13 15
Energy / keV
Energy / keV
Fig. 2-44. Comparison of SRXRF spectra: (a) 100 ng of each element on the fused quartz, by total reflection; and (b) 100 ng of each element on the filter paper, by ordinary bulk analysis. From Ref. [31], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam. Table 2-9 Comparison of the detection limitsa between two different methods by SR excitation Element V Fe Ni Zn Pb Ti Mn Cu Ge
Total reflection (ng) 0.03 0.02 0.01 0.01 0.02 0.04 0.02 0.01 0.005
Bulk analysis (ng) 0.07 0.07 0.05 0.04 0.04 0.07 0.06 0.06 0.03
a The detection limit is defined as the quantity which gives a signal equal to three times the square root of the background. From Ref. [30], reprinted by permission of Kodansha, Tokyo.
129
Zn
1 400-
12 0 0 -
Cu Ni
"-:"
=. I O 0 0 ;~
800
~o
600
~9
-
E~" 12 keV t 91000 s MAX.CTS 91361
Fe
Mn Cr
-
Scat.
400200 0
I
I
i
I
I
0
5
10
15
20
Energy / keV Fig. 2-45. SR-Excited TXRF spectrum from the sample prepared by drying 100 lxl of a solution containing 50 ng of each element (V, Cr, Mn, Fe, Ni, Cu, and Zn) on a silicon wafer.
10,,-:,. ::::186-
v
..
--
^
v . X
.
.
.
v
X
4-
~20 i
I 22
I 24
I 26
I 28
I 30
I 32
Atomic number Fig. 2-46. The X-ray fluorescence intensity values of each element, corrected for excitation efficiencies, fluorescence yields, relative Ktx line intensities, and air absorption between the detector and the sample shown in Fig. 2-45.
This method, however, has many problems when it comes to quantitative analysis. One of these involves sample preparation. It is virtually impossible to make a quantitative estimate because of questions concerning where the sample solution is dropped on the reflector, how large an area it covers, and whether it is spread uniformly. It is also difficult to determine where on the sample the X-ray falls. One solution to this problem is to use an internal
130 standard. Pella and Dobbyn [44] used this method to measure the ppb concentration level of Se in human blood serum, using germanium as an internal standard. For trace analysis in the total reflection geometry, using the internal standard, monochromatic excitation with SR allows us to quantify elements reliably and easily, and to improve detection limits compared to X-ray tube excitation. As an example, we will describe an experiment on a NIST reference material (Trace Elements in Water, SRM 1643b). The spectrum of the total reflection X-ray fluorescence for this sample is shown in Fig. 2-47a. A 15 keV X-ray obtained using a Si(111) double-crystal monochromator was used for excitiation. Next, Ge, which was absent from the original sample, was added to bring the concentration up to 70 ng g-1. Then, 100 l.tl of this solution was dried on the reflector. Its spectrum is shown in Fig. 2-47b. The values for the other elements, determined from the amount of Ge, after corrections for excitation efficiency, fluorescence yield, relative Ko~ line intensity and air absorption between the sample and the detector, are indicated in Table 2-10. The detector efficiency is assumed to be constant for the given energy region and the values are in good agreement with the NIST certified values. However, this method has limited applications, since an element not originally present in the sample has to be added. The following procedure can deal with any detectable element as an additional element and is expected to be applied to trace element analysis in liquid samples [45]. For measurements employing the energy dispersive method using monochromatic excitation, the following relationship holds between the concentration of element i contained in the sample and the intensity of X-ray fluorescence [46]: Tabel 2-10 Quantitative determination of several elements in NIST SRM 1643b (Trace Elements in Water) by SR-excited TXRF using Ge a as an internal standard Element
Determined (ppb)
Certified (ppb)
V Cr Mn
49 23 27
45.2+0.4 18.6+0.4 28 +2
Fe Co
120 42
99 +8 26 +1
Ni
49
49 +3
Cu
30
21.9+0.4
Zn
71
66 +2
a Ge was added to SRM 1643b so as to contain 70 ng g-1 in the aqueous solution for measurement.
131 Ci_
li4xR 2(]2s, o +/Zs,isin ~/sin ~)[Ps PoOi[(lIK/P)oOJKfK]i(1 - exp{-[(/Zs,o +/2s,isin tF/sin ~)/ps]psT/sin tF} )
(2-30)
where: C i is the concentration of analyte element i. li is the fluorescence intensity for the analyte line of element i. Po is the intensity of the exciting X-ray beam. Di is the detector efficiency. R is the distance from the sample to the detector. l,ts,o is the linear absorption coefficient of the sample for the exciting X-ray beam energy. l.ts,i is the linear absorption coefficient of the sample for the fluorescence energy of element i. is the incident angle of the exciting X-ray beam. is the angle between the sample surface and the detector, the takeoff angle.
Ps is the density of the sample. T is the thickness of the sample. (,UK/P)o is the mass absorption coefficient of analyte element i for the exciting X-ray beam. tOKis the fluorescence yield of the K-series line.
fK is the intensity ratio of Ks to the total K-series lines. When the sample is very thin, this can be approximated by Ci =
li 4 x ' R 2
(2-31)
PoDi[(l.tK/P)oCOKfK]iPsT / sin tp The term [(l.tK/P)otOKfK]i is a quantity peculiar to an element, that is the constant of its element parameters; the remaining terms, excluding li, 4r~R2/(PoDiPsT/sin tF), are a constant parameter determined by experiment (assuming the detector's efficiency to be independent of X-ray energy). If the term [(PK/P)oOJKfK]i denotes ei and the remaining terms, excluding li, are represented by K, the above equation will be reduced to
Ci =
K
li
(2-32)
9e i
which is validated by the data shown in Fig. 2-46. However, when a solution with a high salt concentration is used, the salt will remain on the reflector after drying, and affect the measurement by absorbing some X-rays. Using a first approximation, to correct this absorption by the matrix we add the correcting term exp(tz~i3). This is based on the assumption that the absorption coefficient of an X-ray is approximately proportional to the cube of its wavelength: 2~"is the wavelength of the fluorescent X-ray of the analyte element i, and a is a quantity which depends on the absorption, and will be determined experimentally.
132 5
10
4
10
-
/
\
(a)
Ca Ca
Fe
Ni
4"
"]
E r" 15keV t 9500 s
MnCO Cu Cu
-
tCr+lCo! +As ~ +Fe JIN~//I/Z l ~ S e
10 3-
i rMn~ I
n
Scat.
]As
0
1 02 1
10
-
MAX.CTS 918468 B.S. 90.11 x 2.8 mm 2
10 ~ 0
i
!
i
5
i
10
15
20
Energy / keV 10 10 "
.1-,~
5
4
10 1
(b)
-
-
Cu Mn Ni ,7+ + [, ~n -Fe F e l N i l
F_7 915 keV t 9200 s
+
iv
-
o~
Co
Ca ~Ca
As ~ ~ Ge
Scat. /~
C
-
1
10 10
:0.15 x 3.0 mm
B.S.
0
0
~[
I
I
I
I
5
10
15
20
Energy / keV Fig. 2-47. SR-Excited TXRF spectra from the samples obtained by drying 100 ~tl of NIST SRM 1643b, (a); and the solution prepared so as to contain 70 ng g-1 of Ge in SRM1643b, (b).
Let us consider the case of three elements in unknown amounts contained in a sample. The intensity of the X-ray from each element is related to its concentration as follows:
C1 -
ll.exp(aZ13)
K.el
(2-33)
133
C2 =
C3 =
12.exp(aA 3)
K.e2 13.exp(aA 3)
K.e3
(2-34)
(2-35)
If two of these elements are added at specific concentrations (Ci', i = 2, 3), then
C1 =
C2+ C2' =
C3+ C3' =
ll'.exp(aA13)
K'.el 12'.exp(a~,23)
K'.e2 13'.exp(o~A33)
K'.e3
(2-36)
(2-37)
(2-38)
In these six equations, (2-33) to (2-38), li and li' are measured values and ,~,i and ei are peculiar to these elements - - v a l u e s that can be determined using constants. Thus, there remain six unknown quantities, K, K', Ci (i = 1, 2, 3), and a, which can be determined by solving simultaneous equations. Quantitative analysis will be possible for elements other than these three, using the values of K and a determined using the equation
Ci = li . exp(aA/3) / K.ei
(i>4 )
We made measurements on two kinds of samples. One was the synthetic standard used in the experiment shown in Fig. 2-46, and the other the NIST standard reference material used for the experiment shown in Fig. 2-47. For the calculation of quantitative values, the synthetic sample and NIST SRM were each divided into subsamples, A and B. Vanadium and nickel were added to subsamples A until the concentration of each element reached 50 ng g-1. Likewise, manganese and zinc were added to subsamples B until the same concentrations of each element were reached. Then, 100 lxl of each sample was dropped onto and dried on a silicon wafer in the same manner as the experiments shown in Figs. 2-45 and 2-47. These preparations were performed in a Class 1 000 clean booth. A 12 keV monochromatic X-ray created using a Si (111) double-crystal monochromator, was applied to each sample at a glancing angle of about 2 mrad. The counting time was 1 000 s. The results of the quantitative analyses listed in Tables 2-11 and 2-12 suggest that this is a very satisfactory method for trace element analysis. It requires no consideration of the spot size or the area irradiated, and provides rapid, simultaneous multi-element analysis of ppb concentration levels using a simple sample treatment. It has a wide range of applications since unknown amounts of the elements to be added can be selected. However, the expedient correction used above for absorption by the matrix may be further improved by a more precise approximation.
134 Table 2-11 Results for the synthetic sample Found, ng g-1 Element
Added a, ng g-1
V Cr Mn Fe Ni Cu Zn
50 50 50 50 50 50 50
Addition of V and Ni for calculation b
Addition of Mn and Zn for calculation c
42 48 49 49 55 49 56
42 47 47 47 51 46 52
a Added values are given for comparison. b For the calculation of K and ct, the fluorescence intensities of V, Ni and Cr were used. c For the calculation of K and o~, the fluorescence intensities of Mn, Zn and Ni were used. From Ref. [45], reprinted by permission of the Japan Society for Analytical Chemistry, Tokyo. Table 2-12 Results for NIST SRM 1643b Found, ng g-1 Element
Certified a, ng g-1
V Cr Mn
45.2+0.4 18.6+0.4 28 +2
Fe
99
Co Ni Cu Zn
Addition of V and Ni for calculation b
Addition of Mn and Zn for calculation c
38 14 22
43 15 21
+8
120
114
26 +1 49 +3
28 53
24 47
21.9+0.4
23
20
66
99
86
+2
a Certified values are given for comparison. b For the calculation of K and ct, the fluorescence intensities of V, Ni and Mn were used. c For the calculation of K and ct, the fluorescence intensities of Mn, Zn and Ni were used. From Ref. [45], reprinted by permission of the Japan Society for Analytical Chemistry, Tokyo.
135
2.4.4. Near surface analysis When the incident X-ray is totally reflected it penetrates only a few tens of A into the sample. This property of the TXRF method makes it possible to carry out the elemental analysis of the area near the sample surface. Conventional XRF only performs bulk analysis, and cannot be used to analyze the sample surface. A significant feature of TXRF is that while it maintains the rapid, nondestructive, and simultaneous multi-element analysis of conventional XRF, it can also be applied to surface analysis. This method has been extensively used in the laboratory for surface analysis of silicon wafers. However, there have not been many cases where SR has been used for surface analysis where the samples must be handled carefully. It is very difficult not to contaminate samples from the time they are prepared in the laboratory, through transportation, until they are measured at a SR facility. In this section, we will discuss precautions for using SR-excited TXRF for surface analysis. Any element on the surface will cause X-ray fluorescence. However, the intensity of the fluorescence varies, depending on whether the elements are on the sample surface or slightly below it. This difference is illustrated in Fig. 2-48, which shows the calculated dependence of the X-ray fluorescence intensity on the glancing angle, for the same quantity (1012 atoms cm -2) of iron distributed inside silicon in the following ways: (1) close to the surface, (2) homogeneously from the surface to a depth of 10 A, (3) homogeneously from the surface to a depth of 100 A, and (4) homogeneously from the surface to a depth of 1 000 A. It should be noted for quantitative analysis that the X-ray fluorescence intensity caused by the same amount
,--:,.4A
: top surface ..... : surface to 10 A - - -: surface to 100 A
~39~ 2 o o r,o
1s,
0-
s"
........ ...I
2
I
4
I
6
I
8
I
10
G l a n c i n g angle / m r a d Fig. 2-48. The calculated glancing angle dependence of Fe Ko~ intensities on the following distributions of Fe (1012 atoms cm -2) in the silicon substrate: (1) only on the top surface; (2) on the homogeneous distribution from the surface to 10 A in depth; (3) on the homogeneous distribution from the surface to 100 A in depth; (4) on the homogeneous distribution from the surface to 1 000 A in depth.
136 of element varies greatly depending on the distribution and the glancing angle. At the Photon Factory, Iida et al. [47] measured the dependence of X-ray fluorescence on the glancing angle, using a 3.5-l.tm-thick Gal_xAlxAs thin film (x - 0.298) epitaxially grown on GaAs. In comparison with GaAs, there were fewer As atoms near the surface of this thin film. This is mostly due to sublimation that occurs during sample preparation. To estimate the depth of the reduced As concentration they calculated the exhausted length (the distance from the surface to where the concentration is 1/2 of the bulk concentration value) to be about 100 /~, on the assumption that the As concentration increases from the surface value of zero to the bulk value in the manner of a complementary error function. Changes in the chemical composition of compound semiconductors can also be measured by destructive methods, such as ion channeling and SIMS; however, the present method does not destroy the sample. Bloch et al. [48] performed an experiment at SSRL on the interface between a polymer solution and the air. The method they employed allows measurements in any atmosphere, and therefore is suitable for analyzing the surface of liquids. They positioned an optically flat reflector in front of the sample, to control the glancing angle of the incident X-ray. The sample was a slightly sulfonated polystyrene dissolved in dimethyl sulfoxide. The polymer had a molecular weight of 115 000, with a chain containing about 10 mole% manganese sulfonate. By measuring the dependence of the S Ka from the solvent and the Mn Ka from the polystyrene on the glancing angle, they found that the polymer concentrations increased on the interface, since the Mn intensity was higher at smaller angles. With uniformly soluble MnC12, the intensity ratio was found to be constant. They also compared this method with the optical method. The minimum penetration depth is a few tens of A for X-rays and hundreds of A for the optical method. Also, in the optical method, polymer solutions are generally transparent to a depth of a few thousand/~, allowing penetration to infinite depths at angles above the critical angle. This means that the X-ray method provides a far more sensitive surface analysis for this kind of sample.
2.4.5. Depth profile analysis As shown in Fig. 2-38, the penetration depth increases from a few tens of/~ to a few l.tm as the glancing angle of the incident X-ray increases beyond the critical angle. This means that the depth profile of the element being studied can be analyzed by changing the glancing angle in small increments. Iida et al. [17] used a silicon wafer ion-implanted with As to measure the dependence of the intensity of As K a X-ray fluorescence on the glancing angle (1-5 mrad). They also made the same measurements on a sample heat-treated at 1 000~ for 20 min. As shown in Fig. 2-49, the increase in As concentration on the sample surface brought about by the heat treatment gives a greater intensity of X-ray fluorescence below the critical angle. The decrease in the intensity at glancing angles above the critical angle corresponds to a reduction of the total amount of As. The demonstrated intensity of X-ray fluorescence has been found to agree well with the value calculated using the profile analyzed by the SIMS method.
137 _1
'
I/.~
/ -
/
/
/
/
\
'
I
'
I_
\ '
A
-
o~==l
tD - / / o1-,~
\
I
1
""
B
/
-
2
\
i
I
-!
i
3
4
Glancing angle / mrad Fig. 2-49. Reflected X-ray intensity (broken line) and As K intensifies (solid lines) for Si wafers, before (A), and after (B), annealing, as a function of glancing angles. From Ref. [17], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
Figure 2-50 (dotted line) shows a depth profile analysis of a silicon sample ion-implanted with iron (40 kV, 1 x 1015 atoms cm -2) [31]. Iron ion-implanted in this manner shows a Gaussian distribution, with a 123 A standard deviation around the peak ion concentration at a depth of 302 ,~. The dependence of the X-ray fluorescence on the glancing angle, calculated from this profile, is shown by the solid line in the figure. The slight difference from the measured values is probably due to the spread in energy and angle of the beam. We made the following calculations to ascertain how sensitive the curve of the X-ray fluorescence plotted against the glancing angle is to the depth profile. Using Fresnel's formula [43], the amplitude, At, of the transmitted X-ray is given by
A t _ 201 Ai 01+02
(2-39)
where Ai, 01 and 02 have the values indicated in Eq. (2-23). The intensity of the transmitted X-ray just beneath the surface is given by
~_~ 2
=
4 012 (01 +p2) 2 + q22
(2-40)
138 [In the actual calculation, the values of 01, P2 and q2 are used 9See Eqs. (2-24)-(2-26).] The transmitted X-ray, expressed by Eq. (2-40), is transmitted in the medium while being absorbed. The X-ray fluorescence intensity for an element distributed at a given depth in the medium is calculated from the transmitted X-ray intensity and the concentration of the element at that depth. Figure 2-51 shows the calculations for the ion-implanted iron described in Fig. 2-50, with different standard deviations for their Gaussian functions 9 The calculated Fe Ka intensity vs. the glancing angles, at different depths of peak concentration, are shown in Fig. 2-52. The X-ray fluorescence profile is found to be quite sensitive to these parameters. Application of this characteristic to thin film samples will be discussed in detail in the following section. Measuring the depth profile of impurities at the surface during the analysis solves the problems mentioned in the preceding section, i.e., the difficulty in making a quantitative determination of an element caused by the dependence of the X-ray fluorescence intensity on the elemental concentration profile. Various applications of the above method are expected because of the nondestructive depth profile analysis in air that it provides.
1E22
_ _ _ Calc. 302.~
"
Exp.
d
"IE16 0
O
Depth (/~)
1000
O
0
1
2
3
I
4
I
5
6
Glancing angle / mrad Fig. 2-50. Depth profile analysis of implanted Fe in a silicon wafer. From Ref. [31 ], reprinted by permission of Elsevier Science Publishers B. V., Amsterdam.
139 2.5-
.
,~
:300A
i
:c=100
~~ .2~ . 0 -
.......
: o =
5 0 ko
~15-
~
~
9v.,,l
~l.Or~
os-
0
"
0.0 . . . .
0
I
2
I
I
4 6 Glancing angle / mrad
I
8
I
10
Fig. 2-51. The glancing angle variation in Fe Kcz intensifies with different Fe concentration distributions in a silicon wafer, changing standard deviations (cr) at a fixed peak depth (Zp) of 300 ,~ below the surface in a Gaussian distribution. (o" is the halfwidth at half of the maximum concentration)
3 . 0 - -
c~" 100 .,~
,.~,,~2 . 5 -
:
9
'i ~~,,,
~t=2 0 - "
zp = 3oo A
....... : Zp = 200 .A Zp 400 A
o
"-" 1 . 5 o
i
o10-.
=._.
. . . . . . . . . .
=_.
r~
o0.5-
se
#
0.0-
0
2
4
6
8
10
Glancing angle / mrad Fig. 2-52. The glancing angle variation in Fe Ko~ intensifies with different Fe concentration distributions in a silicon wafer, changing peak concentration depth (Zp) below the surface at a fixed standard deviation (o') of 100 A in a Gaussian distribution.
140 2.4.6.
Application
to thin film s a m p l e s
TXRF is effective not only for the elemental analysis of a sample surface, but is also useful for the analysis of thin films. As explained above, the depth of penetration of the incident Xray can be controlled by changing its glancing angle to the sample. This makes it possible to match the measurement conditions to the sample thickness. We will discuss an experiment using a 1.2-gm-thick photoresist polymer coated on a silicon wafer [ 18]. Small amounts of impurities in photoresist polymers are normally measured by chemical analysis. In this case, TXRF was chosen because the impurities were in a thin film spread on a wafer. The experiment was conducted using Beamline 4A at the Photon Factory. A 9.6 keV monochromatic X-ray with a Si(111) double-crystal monochromator was utilized. The intensities of the incident and reflected X-rays were measured using an ionization chamber, and the intensity of the X-ray fluorescence measured using a Si(Li) detector. The sample and the detector were 5 mm apart. The measured reflection curve is shown in Fig. 2-53. The curve shows two critical angles. That in the low glancing angle region is the critical angle for the resist polymer, and the other, in the high glancing angle region, the critical angle for the silicon wafer. This means that, if the incident angle is gradually increased from a low value, the behavior of the incident X-ray will be changed in the following manner. First, it is totally reflected on the resist surface. Then, as the glancing angle becomes greater than the critical angle of the resist (2.15 mrad),
1.0 0.8 ~. 0 0
0.6 0.4
0
0.2 I 2
I
I 3
I
i--r------4
Glancing angle / m r a d Fig. 2-53. The observed angular dependence of reflectivities from a silicon wafer covered with a resist polymer. The critical angle of the resist is around 2 mrad, and that of silicon around 3 mrad [ 18].
141 the X-ray penetrates the polymer, and is totally reflected on the silicon-resist interface until the glancing angle reaches the critical angle of the silicon wafer (3.20 mrad). The reflection curve rises until the glancing angle reaches the critical angle, because of the change in the effective cross section of the incident X-ray. We measured the X-ray fluorescence using glancing angles of 2 and 3 mrad. The measurements were made in air and lasted for 2 000 s. At 2 mrad, the maximum penetration of the X-ray into the resist is only 100 J., and most X-ray fluorescence is emitted from the surface. At 3 mrad, the measured X-ray fluorescence comes from all parts of the resist film. The spectra of the X-ray fluorescence for these two cases are shown in Fig. 2-54. Both show X-ray fluorescence from the silicon substrate, argon in the
0=2 mrad 0 =3 mrad
~ ~
es'st
~, ~
t
Silicon (a)" Schematic drawing of total reflection with changing glancing angles (2 mrad and 3 mrad).
10
105 /L
0= 2 mrad
0= 3 mrad
/
~~
4|
10[ Ar 10 3
8
Scat.
Si
Scat.
l~
]
/
,o31 - tt
102
0
5
Energy / keV
10
0
5
10
Energy / keV
(b): SR-Excited TRXF spectra obtained. On the left side (2 mrad) total reflection occurs on the resist surface; on the right side (3 mrad) on the interface between the resist and silicon wafer. Counting time is 2000 s. Fig. 2-54. Impurity (Fe) analysis in a thin resist film on a silicon wafer [18].
142 air, and iron which is regarded as an impurity in the sample. The problem with measuring the quantity or distribution of the profile of iron is the dependence of the X-ray fluorescence intensity on the depth profile, as described in the previous discussion on surface analysis. Assuming the total quantity of iron to be constant, we calculated the intensity using the two glancing angles (2 mrad, 3 mrad) for the following four kinds of distributions: (1) homogeneous from the surface to 10 A, (2) homogeneous from the surface to 100 A, (3) homogeneous from the surface to the interface, (4) decreasing linearly from the surface to the interface. The calculated values for 2 mrad are: (1) 0.74, (2) 0.49, (3) 0.007, and (4) 0.014; and for 3 mrad: (1) 0.31, (2) 0.28, (3) 0.24, and (4) 0.25. Note that the unit for these values is arbitrary. The peak area of the X-ray fluorescence of iron measured in this experiment has been found to be four times as large at 3 mrad as at 2 mrad. We attempted a quantitative analysis, based on the assumption that the iron concentration was homogeneously distributed on the thin resist film and that it also contaminated the surface of the film. Comparing the measured and calculated values of the X-ray fluorescence intensity using 2 and 3 mrad we found that 92% of the iron detected was homogeneously distributed in the film, with 8% contaminating the surface. Our estimate of the amount of iron showed that 1.7 x 1012 a t o m s cm -2 were contained inside the film with 1.5 x 1011 atoms cm -2 attached on the surface. The amount of iron contained inside is converted to approx. 1.3 ppm in relative weight concentration- a value in good agreement with that obtained by chemical analysis (1.0 ppm). However, the depth concentration profile must be measured if one needs a more precise quantitative determination. 2.5. C H A R A C T E R I Z A T I O N OF LAYERED STRUCTURES BY GRAZING INCIDENCE
2.5.1. X-Ray spectroscopy using grazing incidence As discussed in the preceding section, the penetration depth changes as the incident angle of X-rays changes around the critical angle of total reflection. Also, under these conditions the incident X-rays interfere with reflected X-rays. Interference occurs inside the film in a sample with a layered structure, which affects the reflection curve and the X-ray fluorescence intensity profile for the constituent elements. The interference effects depend on factors which include the number and thickness of layers, the concentration profile, the roughness of the surface or interfaces, and the existence of transition layers on interfaces. This makes it possible to determine important parameters of the film structure, by analyzing the reflection curve and the X-ray fluorescence intensity profile measured as functions of the glancing angles. For multilayered materials, the following parameters can be determined by this method: (1) The thickness and density of individual layers. (2) The concentration profile of constituent elements. (3) The roughness of the surface or interfaces. (4) The existence of transition layers between the surface and the thin film, and between a
143 thin layer and the substrate, as well as the thickness, density and composition of the transition layers. (5) The depth profile of impurities. Interference shows up as oscillations on the reflection curve. Back in the 1930s, Kiessig [49] analyzed oscillations in the curve exhibited by reflection from a monolayer thin film, and described a method of determining film thickness. He regarded the oscillations as fringes of equal inclination, and determined the film thickness from a relationship between it and the optical path difference. Parratt [50] formulated a rigorous method for calculating the reflection curve for multilayered materials, and attempted to analyze these materials from the changes in the reflection curve, especially around the critical angle. He made systematic calculations on oxidized layers of copper, and compared them with experimental results. N6vot and Croce [51] gave a more rigorous definition for the conventional method of incorporating interface roughness as a Debye-Waller factor [a scalar treatment, see Eq. (2-29)] and obtained an equation that enabled a vectorial analysis. They used this equation in a detailed analysis of surface layers of polished glass. They measured the reflectivity at glancing angles varying from the critical angle to much larger values. This is important in determining very sensitive roughness values, since roughness has a great effect on the reflection curve, particularly when the glancing angle is large. Generally speaking, reflectivity is very small at large glancing angles. Therefore, careful experimentation is required to determine oscillations in reflectivity with high precision. Vidal and Vincent [52] developed a matrix calculation method to systematically determine reflectivity for multilayered materials using a computer. The roughness term is also incorporated in the matrix elements. They used this method to evaluate layered synthetic materials. Kr61 et al. [53] established a method of calculating the angular dependence of X-ray fluorescence intensity. Using the matrix treatment of Vidal and Vincent, this method enabled a rigorous determination of X-ray fluorescence emitted from individual layers. The experiments were carded out on the thin layers of semiconductor wafers. In the above experiments, only Kr61 has used SR. This is not necessary for measuring reflection curves; careful measurement using specially designed equipment produces satisfactory results. In fact, as well as N6vot and Croce, Huang and Parrish [54] performed precise experiments using equipment they had developed incorporating a channel-cut monochromator. However, monochromatized X-rays obtained from SR are useful for the measurement and analysis of X-ray fluorescence intensity profiles. The high intensity, tunability, and high collimation of SR are indispensable for measurements of minute compositions and applications to very thin films and transition layers. Sakurai and Iida [55] have proposed a method for determining each layer thickness of mutilayered thin films by a Fourier transformation of oscillations known as the Kiessig structure [49]. Other research using the grazing incidence method includes a laboratory study, in combination with ellipsometry [56], of a thin film on a compound semiconductor, and an effort to examine heterojunction roughness using soft X-rays (SR) [57, 58]. Heald et al. [59] used the grazing incidence method to measure both reflection curves and EXAFS, in order to analyze metallic multilayers.
144
2.5.2. Determination of the thickness of monolayer thin films (Kiessig's method [49]) Kiessig established a simple method for determining the thickness of monolayer thin films. He assumed the oscillations that appear in the reflection curve to be fringes of equal inclination. When the X-rays are incident at an angle slightly larger than the critical angle of the sample, part of the X-ray beam goes into the thin film. As shown in Fig. 2-55, X-rays reflected by the surface and by the interface interfere with one other. The reflectivity from the interface is so small that X-rays emitted after repeated reflection within the film can be neglected. The X-rays can be assumed to be parallel beams (coming from a light source infinitely far away), and the two beams (AB and A'B') which interfere are parallel and come from the same incident X-rays. We write N for the foot of a perpendicular line, A'N, dropped from A' to AB. Since there is no optical path difference between the two beams beyond A'N, the difference in the optical paths is expressed by A = n2.(AC + CA' ) - nl.AN
(2-41)
where nl is the refractive index of air or a vacuum (=1), and n2 is the refractive index of the film, which takes a complex number if there is any absorption. Let the film thickness be dE, then, since 01, 02<<1, the optical path difference is expressed by
Air (vacuum): n = n 1 = 1
B ~ / B
N
d2
~
~monolayer:
Substrate: n = n 3 Fig. 2-55. Schematic representation of fringes of equal inclination.
n =n
145
A
=
2d2 02 = 2d2( 0 7 -
02 ]1/2
(2-42)
lc/
See Eqs. (2-4) and (2-23) for the meanings of 01, 02 and 01c. The intensity of reflected Xrays is a maximum or minimum value when the optical path difference is an integer (m) or a (m + 1/2) multiple of the wavelength. Therefore, changes in the intensity of reflected X-rays depend on 01. Let the wavelength of the incident (reflected) X-rays be ~; then the intensity becomes a maximum value when:
mA = 2 d2(O2 - 021e!]1/2
for&<&,
(m + 1/2) A, = 2 d2(07 - 02) 1,2
for & > &
and (2-43)
The term (m + 1/2) is required because a phase shift occurs during reflection when d;2 > 63, i.e., the electron density is higher in the film than the substrate. See Eq. (2-2) for definitions of 62 and t~3. From Eq. (2-43), the values of 01 corresponding to the m-th maximum is related to m as follows:
021(m) = 02 + $2m2
for $2 < 63,
4d~ and
O2(m) = 02c + A 2(m + 1/2) 2
44
for ~ > ~
(2-44)
Therefore, 012(m) plotted against m 2 or (m + 1/2) 2 forms a straight line, and d2 can be determined from the slope. Therefore, highly accurate determinations of the film thickness can be obtained without contact with or destruction of the sample. Further, since 01c [= (262) 1/2] can be determined from the intercept of the line, the density of the thin film can also be obtained. We carded out an experiment on a Ni thin film deposited on a silicon wafer using a sputtering method. Measurements were made using 1.2 A monochromatized X-rays at Beamline 4A of the Photon Factory. The reflection curve measured is shown in Fig. 2-56. Oscillations can be seen in the curve. Since nickel has a larger t~than silicon (62 > 53), 012(m) corresponding to the maximum oscillation was plotted against (m + 1/2)2 (Fig. 2-57). The result is a straight line. From the slope of the line, the thickness of the Ni thin film was determined to be 454 + 3/~. The critical angle (01c) was found to be 5.6 + 0.2 mrad. As described above, it is easy to determine the film thickness and the critical angle, i.e., the sample density and composition of a monolayer thin film. However, this method cannot be applied to samples having more than one layer or having transition layers.
146
10
;~' 10-
o
1
;;>
-
-
2
lo-~
1
-
10
-4
-m
I
0.0
0.2
I
I
0.4
I
0.6
I
0.8
I
1.0
Glancing angle / degree
1.2
Fig. 2-56. The reflection curve of a Ni thin film deposited by sputtering. The incident X-ray wavelength is 1.2 A. 1.0 0.8 ~~
0.6
~
0.4 0.2 0.0
I
I
I
I
o
20
4o
60
I
a0 (m+l/2) 2
I
I
I
loo
12o
14o
Fig. 2-57. A plot of maximum oscillation values for the Ni thin film on a silicon substrate shown in Fig. 2-56. The straight line was obtained by least-squares.
2.5.3.
Calculation
of reflection
curves-1
(Parratt's
method
[50])
Kiessig's method uses only the period of the oscillations that appear in the reflection curve. More information would be available if it were possible to analyze the entire reflection curve, including the amplitude of the oscillations. It is also important to have a method for analyzing multilayered thin films. One way to analyze the reflection curve is to determine the parameters such as the film thickness and composition, and to construct a theoretical curve; the parameters are then adjusted to make an experimental curve fit the theoretical curve. It is therefore necessary to have a theoretical method for calculating the reflection curve. Parratt formulated a method for determining the
147 reflectivity of grazing incident X-rays for multilayered samples, using the electromagnetic theory (continuity of the tangential components of electric and magnetic fields on interfaces) and Fresners optics formulae. When monochromatized X-rays irradiate a sample, (without multilayers), the electric field vectors of the incident [El(Zl)], reflected [E~(zl)], and refracted [E2(z2)] X-rays are expressed as follows:
El(z1) - El(0)exp{i[(.ot -(kl,xX1 + kl,zZl)]) E~(z1) = E[(0)exp{i[~ot -(kl,xXl - kl,zZl)]} E2(z2) = E2(0)exp{i[~ot -(k2.~x2 + k2.zZ2)]}
(2-45) (2-46) (2-47)
where z denotes the perpendicular distance from the surface (which has a positive value in the sample), and k i (= 2~/Ai, i=1, 2) is the propagation vector of X-rays. Suffix 1 represents the outside of the surface, and suffix 2 the inside. The plane of incidence is an xz plane. The continuity of the tangential component of the electric field vector on the interface requires that, if there is a grazing incidence, the following holds true: k2.x = kl, x = kl, and k2.z = k102 = kl (012- 2 6 2 - 2ifl2) 1/2. From Fresners formulae, the reflectivity can be expressed as a function of the glancing angle by
01 + 02
(01 + p2)2+ q2
(2-48)
where P2, q2, 01, and 02 are defined in the same way as in Section 2.4.2.: see Eqs. (2-24)-(226). Now consider a sample having N layers (air, 1; layers, 2 to N - l ; substrate, N). Assume also that the interfaces are perfectly smooth. Denote the thicknesses of individual layers as dn. The thickness of the air, dl (vacuum), will not be considered. From the boundary condition of the continuity of the electric vectors on the interface, there is the following relationship between layers n-1 and n (n = 2, 3,..., N):
an-lEn-1 + an-l_l Er_l = a-nllEn_ (an-lE,-1-an-l_l E r _ l ) f , - l k l = (
+ an E~
a~lxE.-a. Er)Lkl
fn = Pn - iqn an = exp( - iktfndn / 2 )
(2-49) (2-50) (2-51) (2-52)
[En is the value on the n-th interface of the electric field that propagates downward (to the substrate) through the interface; En r is the value on the n-th interface of the electric field
reflected upward from the interface (to the surface)]. From these equations, the reflection
148 coefficients of the electric fields' amplitudes are expressed by the following recursion formulae:
rn-l,n =
a4_l( rn,n+l + Fn-l,n)
rn,n+lFn-l,n + 1
(2-53)
rn,n+1 = a2n (E r / En)
(2-54)
fn-1 - f n Fn-l,n =fn-1 + fn
(2-55)
The calculation starts with n = N, and proceeds until the reflectivity R = I rl,212 is determined. Note that rN,N+I = 0, since there is no upward electric field, EN r, in the substrate. The parameters required for these calculations are dn (film thickness), Sn (composition and density), and fin (composition and density). A comparison of the calculated results with the experimental values makes it possible to establish an optimum model of the multilayered structure. Parratt measured the reflection curve of a copper film (thickness approx. 2 000 A) deposited on glass, and compared the results with the values calculated by the above method. First he used a two-layered structure of copper and glass. The reflection curves did not agree very well, and the value of ~, which is proportional to density, was found to be about 10 percent smaller than the value for bulk copper. Then he considered a three-layered model with an additional oxide (Cu20) layer, and searched for an optimum model by changing the thickness of each layer. He went as far as a five-layered structure: Cu20 (90% density of the bulk value) + Cu20 + Cu (90% density of the bulk value) + Cu + glass. Although the calculated results did not coincide perfectly with the experimental values, they provided quite a good approximation. These results suggest that, in order to examine the structure of thin films, even monolayer materials must be regarded as multilayered. This means a satisfactory analysis cannot be based only on the period of the oscillations; the entire reflection curve must be considered. This is why it is very important for thin film analysis to have a method, such as the one shown in this section, for calculating the reflectivity of multilayered structures. Unfortunately, the calculations are tedious when the sample has many layers.
2.5.4. Incorporation of roughness and transition layers Real samples have rough surfaces and interfaces. They can also contain transition layers. Omitting these factors from the reflectivity calculation prevents precise comparisons with experimental results. A rough interface and transition layers reduce reflectivity, which can be observed in the reflection curve. We will describe the method for incorporating these factors which was established by N6vot and Croce [51 ].
149 Consider an interface where homogeneous substances meet. The refractive indices can be represented by n l (upper layer) and n2 (lower layer). The roughness of the interface, as shown in Fig. 2-58, is expressed as the root-mean-square of deviations of the depth coordinate ZD.
0.2 = ( z 2 )
(2-56)
If the roughness value is not very large, it will be smaller than kln -1, k2n-1 (kin is the normal component of wave vectors for each layer, i). A real rough interface can be considered as many smooth planes distributed in a Gaussian manner. The peak of the Gaussian distribution is the average plane (P0) of the deviations of the rough interface. Therefore, using this assumption, if the reflection coefficient of a perfect interface is represented by ri, that for a rough interface, re, can be described by rR = rlexp(
-
81r,2klnk2n0.2)
(2-57)
The reflectivity is given by the square of the absolute value of the refection coefficient (R = I rR 12). The above equation also gives the reflectivity of a transition layer whose refractive index changes in the manner of an error function. If we assume that
9
m
n(z)= nl + (n2- nl).F(z)
(2-58)
F(z)=l~fZ___ooex[~ -v2x0-2
(2-59)
20.2 ,u2]du
,
+++
+
+++P0
/I
I
++
Fig. 2-58. Schematic representation of a rough interface: Po is the average plane surface (perfect interface); P is the actual interface.
150 when nl is unity (the refractive index of air or a vacuum), we obtain the same reflectivity in a similar manner to the method for the rough interface above. Namely, consideration is made by substituting a transition layer for a rough interface, and the refractive index for the parameter representing the roughness. Conversely, a transition layer as shown in Eqs. (2-58) and (2-59) can be used to analyze interface roughness. Now consider a multilayered material, as shown in Fig. 2-59. The amplitudes of the electric fields are represented by a, b, a, and ft. Since only transmitted X-rays exist in the substrate, if aj_ 1 is known, Eq. (2-57) can be used to determine bj-1 o n the Oj-1 interface. The following relations hold on the Dj_ 2 interface.
OtJ-1 + rR'j-2~J-I 1 + rR, j_ 2
(2-60)
bj_2 = otj_l + flj-1- aj-2
(2-61)
aj-2 -
where rR, j-2 is the refection coefficient on the Dj_2 interface, defined by taking into consideration its roughness and transition layer. Consecutive calculations to the first layer, D1, determine the reflectivity of the multilayered material, I bl[al I2. N6vot and Croce [51 ] used the above method to analyze a thin layer formed on a surface by polishing, oxidation, or contamination. We will describe their analysis in the following. The a M
bl
1
D1
M
M i-2
~
~
b1_2
DF2
M j-1 u.
DF1 i
aj Substrate
Fig. 2-59. Sketch of electric fields for a multilayered material.
r Z
151 surface layer in question is assumed to be sufficiently thin (less than a few tens of A). Its refractive index and thickness are also assumed to be sufficiently uniform. If the refractive index and the average thickness of the surface layer are denoted by no and 1:o, respectively, the refractive index for a given depth (z) between the surface layer and the substrate (refractive index = n2) is expressed by n2(z) = n 2 + (n 2 - n2)F(z-'ro, or)
fz
(2-62)
0u
F ( z - v o , o') = V2xcr2 J-oo
(2-63)
And, when the layer composition and density continuously change from the surface to depth z2, the refractive index is expressed by n2(z) = n~ + (n~ - n~)[ 1 - exp( - z/z2)]
(2-64)
Using Eqs. (2-58) and (2-59), the surface roughness can also be included in n(z). Ntvot and Croce measured the reflectivity of grazing incident X-rays to examine how various methods of polishing change the surfaces of various kinds of glass. An X-ray tube was used in their experiments. Reflection curves were observed using glancing angles between 0 and 3 ~ For pure silica glass, polished with pine resin mixed with cerium oxide, the refractive index had a maximum value at 51 A, below the surface. This value is obtained by adding Eqs. (2-58), (2-62), and (2-64) and by comparing the reflectivity determined from the experimental results with that from the calculated ones. This means a high-density layer was formed at that depth. It was also found that it could be eliminated by heat treatment. The value for z2 obtained in this case is 225 A, and the refractive index decreases continuously according to Eq. (2-64). It was also found that the surface was not dense, having a roughness of 7.75 A. They also discovered that when aluminosilicate glass (density, 2.63; SiO2, 60%; A1203, 20%; CaO, 20%) was polished using pine resin mixed with iron oxide, a very thin low-density layer (density, 2.04; Zo, 21 A) was formed, with a high-density layer below (maximum density, 2.71 at 48 A; z2, 200 A). The surface roughness was found to be 9 A.
2.5.5. Calculation of reflection curves-2 (Matrix treatment) The methods for calculating reflectivity indicated in Sections 2.5.3 and 2.5.4 require complicated data handling when there are many layers. Vidal and Vincent [52] reported a very convenient method for calculating the reflectivity of multilayered samples incorporating roughnesses. In this method, one matrix corresponds to each layer. TO handle a multilayered film, the matrices representing the layers can simply be multiplied.
152 First, we will discuss the case where roughness is omitted, as shown in Fig. 2-60. The electric fields above and below the interface (y > Yo, Y < Yo) can be expressed by
e(x,y) = [E2exp( - i(2y) + e~exp(+i(2y)] exp(itrx)
(for y > yo )
E(x,y) = [El'exp( - i(ly) + El'rexp(+i(ly)] exp(iax) (for y < yo )
(2-65a) (2-65b)
ko=2~/~,
(2-66)
o[ = kocos01
(2-67)
(i = {(koni) 2 - a2} 1/2 (i=1, 2)
(2-68)
where ko is the wave number of the incident X-rays, 01 their glancing angle and ni (i = 1, 2) the refractive index. In the case of S polarization (the electric field vector is perpendicular to the incident plane), the electric fields can be expressed as follows, using the boundary condition of the continuity of electric field on the interface.
/p11
E~
P21
P22
, 69,
E1 'r
Pll -- alext~-i((1 - (2)Y]
(2-70)
P12 = a2ex~+ i ( ( l + (2~]
(2-71)
P21 = a2ext~-i((1 -!- (2)Y]
(2-72)
P22 = a l e x ' + i ( ( 1 - ~2~]
(2-73)
where al = 1+~1/~'2, a2 = 1-~1/(2.
The reflectivity, R, is given by
Medium 2 ( = n 2 ) E2
yo E1 r !
E 1'
Medium 1 ( = n 1 ) r
x
Fig. 2-60. Sketch of electric fields of a perfect interface between two media of refractive indices n l and n2.
153
R = [P21/Pll
I2
(2-74)
The case of P polarization (where the electric field vector is parallel to the incident plane) can also be handled if the above (1/~2 is replaced by (~l/ff2} X (E2/E1)
(2-75)
where ei = ni 2 is the dielectric constant. In the case of a multilayered material, the product of the matrix corresponding to each interface can be simply calculated. This method is very useful because it permits the use of the same procedure to calculate the reflectivity for samples having any number of layers. If cr is the roughness, then for S polarization the matrix will become
(E2) = (p 11exp[4 ~"1-~'2)20"2/2] E:~ p2lexp[4 r + ~'2}20-'2/2]
(2-76) P22ex~4 ~1_~2)2o-2/2]
E1 'r
The roughness of each interface can be determined by comparing the experimental results with the calculations. Vidal and Vincent [52] used the reflection curves for grazing incident X-rays to evaluate a multilayered X-ray mirror. We will employ this method to compare the effects of the surface roughness and interface roughness of a sample with a monolayer. Figure 2-61 shows the reflection curve of a nickel thin film (300 A) on a silicon substrate. It indicates that surface roughness mainly reduces the reflectivity, and interface roughness decreases the contrast of oscillations.
2.5.6. Calculation of X-ray fluorescence intensity The discussions above deal with the angular dependence of reflectivity, which is used for analyzing the structure of thin films. This structure can also be elucidated using the dependence on the glancing angle of the X-ray fuorescence emitted from constituent elements. Since this can be observed for each constituent element, it provides more information than the reflection curve alone. However, X-ray fluorescence from thin films is so weak at grazing incident angles that it was rarely used experimentally until SR became available. In this section, we will describe a method of calculating the intensity of X-ray fluorescence. The structure of a film can then be analyzed by comparing the experimental profile with the calculated results. Kr61 et al. [53] developed a method for calculating the intensity of X-ray fluorescence from multilayered samples, using Vidal and Vincent's treatment of matrices for calculating the reflectivity. Consider a multilayered material shown in Fig. 2-62. Layer j is located above the
154
10
-1
10 ;>.
......
~ , .
o"= 20/~ "'":
-
on a
Ni surface
( ~ = 0 on an interface between Ni and Si )
-2
9v,,,4 .v-,I
0
10
-
9
10-3
;,.
\
_
,,"_'~ :'',
,..
-4 10
-
-5 10
-
I
0
5
I
10
I
I 20
15
Glancing angle / mrad 0 10
-
. . . . . .
_
. . . . . .
_
_
_
_
~ = 20]k on an interface between Ni and Si -1 10
;> r O O
-
-2 10
-
10-3
" "J
_
-4 10
-
-5 10
m,
I 5
0
i 10
I 15
~i I 20
Glancing angle / mrad Fig. 2-61. The calculated reflection curves of a Ni thin film (thickness = 300 A) on a silicon substrate. Dotted lines indicate the case of neither interface nor surface roughness. Solid lines indicate the case of either surface or interface roughness: the upper figure shows values for a Ni surface where (r = 20 ~, and the lower figure shows values for an interface between Ni and Si where o" = 20/~.
j-th interface. If S polarization is assumed, then transmitted X-rays
Ej § and reflected X-rays
Ej- are expressed by
Ef (x,z) = Aj exp(ipjz) exp(ikoxx) E](x,z) = Bj exp(-ipjz)exp(ikoxx)
(2-77) (2-78)
155
kjx = kj cosOj = kj+lCOSOj+1 = kj+l, x = kox pj = kj sinOj + iaj = (kZn 2 - gn2cos20)l/2
(2-79) (2-80)
where Aj, Bj, and pj are complex quantities, and kj and aj are the magnitudes of the real and imaginary parts, respectively, of the complex wave vector. Refer to Fig. 2-62 for Oj. The complex wave vector for layer j is expressed by k02n~, using the complex refractive index, where k0 is the wave number (2~/~) of the incident X-rays and 0 their glancing angle. If the matrix connecting the electric fields above and below the j-th interface is lj, then
l e;(zj) l(1
~j rj l
ei( j)
Ej++l(ZJ)t Ej++l(Zj)=lj t Ei+l(Zj) E;+l(Zj)
where rj and tj are the Fresnel coefficients of reflection and refraction, respectively.
9Air or vacuum
E-~ (Zo)
E+ (Zo)
nj
"
o.
o.
Ej+I(Zj ) -
+ j) Ej+I(Z
E+ (ZN)
j-th interface nj+l
EN (ZN)
nN ns
Substrate
z Fig. 2-62 9Schematic representation of electric fields of a multilayered material.
(2-81)
156
zj,
The matrix, Tj+I(Z-Zj) , that connects the z coordinate, at the j-th interface with a point z inside the layer, (/+1) Zj+l), is determined as follows:
(zj
I
Ej++I(ZJ)~exp[-ipj+,(z-zj)] 0 exp[ipj+ l(Z-Zj)] Ej+1(zj)
E j+ 1(Z)
Tj+,(z-zj) E;+I(Z)
I
E;+l(Z)
(2-82)
Matrix Sj corresponds to the roughness of the j-th interface:
e;-r}e; rj(e;-e;)) SJ = l-~r~ rj(ef-ef ) ef-r~ef e+=exp[-(Pj+l+pj)24[2] ef =ext~-(Pj+l-pj)24]2 ]
(2-83) (2-84) (2-85)
where crj denotes the roughness parameter of the j-th interface. From Eqs. (2-81)-(2-83), the following relation is obtained:
( Ei(zj~ )=
Ei+,(z)
(2-86)
If the matrix that connects the electric field at the substrate with the electric field at the interface between the surface and the air or vacuum is PON,then
pl~
PoN=( pl0N p201N P22 ON
(2-87)
If this matrix is calculated, we can obtain
E~(zo)) Eo(zo)
= PON
where
Es+(ZN)is
leo(Zo)/e~(zo~
E+(ZN) 0
(2-88)
the value of the electric field inside the substrate.
can be obtained by calculating [p2~ ' / pl~
I~
The reflectivity
157 The electric field at below. If
z,
(Zj_1 < Z < Zj), Can be determined using matrix PiN, defined as shown
PjN = IjSj
T j + I ( Z j + I - Z j ) - " 9INSN
(2-89)
ET(z) =Tj(zTz)Pju(e+s(ZU)o) E;(z)
(2-90)
then
Es+(ZN) can be expressed as follows using the electric field of the incident X-rays, Ei. (2-91)
E+(zN) = E~(zo____.._~)= E__i_i p l ON
p l ON
Equations (2-89)-(2-91) make it possible to determine the electric fields in individual layers and in the substrate. Also, using Maxwell's equations, and taking the permeability/lj - 1, the magnetic field can be expressed by -
Hjy(Z)
-
/ko
-
(2-92) (2-93)
=0 +
(2-94)
In order to calculate the X-ray fluorescence intensity, the time average of the density of the energy flow, i.e., the Poynting vector P(z), must be determined. P(z) = C(Re(ExH*) )
(2-95)
where Re is the real part; (), the time average; H*, the complex conjugate of H; and C, the multiplicative constant. Substituting the electric and magnetic fields for the corresponding variables provides the components of the Poynting vector. We now describe the calculation of the intensity of X-ray fluorescence from a given layer. The excitation efficiency, fluorescence yield, and absorption of X-ray fluorescence are ignored. With this simplification, all we have to know is the intensity of the incident X-rays required to excite X-ray fluorescence in layer j. It is necessary also to subtract the X-rays that penetrate the sample without being reflected by the surface, those absorbed by layers up to j - l , as well as those going into layer j+ 1. The Xray fluorescence intensity, for z from zero to zj_l, is given by
158
Yj=C
[
1-R-I=I k
tan ~j = Pjz/Pjx
sin [~z/c)]Pi0(z) J
(2-96) (2-97)
where Pi0 represents the incident X-ray flux, R the reflectivity, ~j the direction of Poynting vector Pj(z), and Pjx and Pjz the x and z coordinate components, respectively, of Pj(z). The quantity ~)j is different from Oj representing the direction of propagation of the electric field [see Eq. (2-80) and Fig. 2-62]. Then, the X-ray fluorescence intensity from layer j can be expressed by
Yj+I- Yj (2-98) In the next section, we will discuss examples of thin film analysis using both the angular dependence of reflectivity and of X-ray fluorescence intensity. The analysis was performed by comparing the results of a SR experiment with the reflection curve and X-ray fluorescence profile obtained by the method of Kr61 et al [53]. 2.5.7. Characterization of titanium wafers
and
carbon-titanium thin films on
silicon
The angular dependence of reflectivity and X-ray fluorescence intensity, measured and analyzed using the grazing incidence method, is described in the following [60, 61 ]. The two samples used were a titanium thin film deposited on a silicon wafer by a sputtering method, and a carbon-titanium thin film also sputtered on a silicon wafer. Parts of these samples were cut off and heated in argon. The experiment was conducted using Beamline 4A at the Photon Factory. A Si (111) double-crystal monochromator was used to monochromatize 10 keV X-rays, which were shaped into a beam of less than 0.1 mm in height and 2 mm in width by passing them through a slit. The intensity of the incident and reflected X-rays was measured with an ionization chamber, and the intensity of X-ray fluorescence with a Si(Li) detector. Figure 2-63 shows the reflection curve measured for the titanium thin film. It reveals that the period of the oscillations is reduced after heat treatment. This suggests that high temperatures thicken titanium layers. However, since the amount of titanium remains the same, this effect is believed to be caused by titanium silicide formation during heat treatment. The observed X-ray fluorescence profiles are shown in Fig. 2-64. An attempt was made to create an optimum model by comparing the results with the calculations done by Kr61 et al. [53]. Curves calculated for a metallic titanium thin film, which was not heat-treated, shown in Fig. 2-65, did not agree with the experimental results. Therefore, the model was modified to fit the reflection curve and X-ray fluorescence profile, with the assumption that additional layers were formed on the surface and interface. Figure 2
159
Heat treatment temperature
/'/
\
"1-x
50~
V
"
'
"
"r.
8 Without heat treatment f
4
f
5
f
6
Glancing angle / mrad Fig. 2-63. Experimental reflection curves for Ti on Si wafer samples (with and without heat treatment). Heat treatment temperatures 9250~ 500~ and 750~ From Ref. [60], reprinted by permission of Plenum Publishing Corp., New York.
I
(d)
~i
(c)
*w~
8
3
4 5 6 Glancing angle / mrad
7
Fig. 2-64. Ti Ktx fluorescence intensity profiles for Ti on Si wafers. Without heat treatment (a); and with heat treatment at 250~ (b), at 500~ (c), and at 750~ (d). From Ref. [60], reprinted by permission of Plenum Publishing Corp., New York.
160
9 I,,,,,I
j~176
f
9 ~,,,I 9 1,,,,,I
i
ov,,~
~
o..,. "
t
i
e~
3
4
5
6
""
7
I
4
G l a n c i n g angle / m r a d
I
5
6
7
Glancing angle / m r a d
Fig. 2-65. Comparison of the calculated curves (broken lines), based on the model, with the experimental reflection curve and Ti Ktx fluorescence profile.
......
-...... Calc.
.=.
9 ~,,,I
. . . j
2
4
5
6
Glancing angle / m r a d
7
3
Exp.
I
4
I
5
I
6
7
Glancing angle / m r a d
Fig. 2-66. Comparison between the experimental results for the sample without heat treatment and the calculations based on the model for a Ti0.42Oo.58 (11 n m ) / T i (43 nm)/ TiSi2 (6 nm)/ silicon substrate. For the oxide layer tS= 9.16x10 -6, fl = 3.55x10-7; for the titanium t~ = 8.56x10 -6, fl = 4.84x10-7; for the silicide t~= 8.08x10 -6, fl = 2.67x10-7; and for the silicon substrate d; - 4.75xl 0 -6, fl = 7.42xl 0-8. From Ref. [60], reprinted by permission of Plenum Publishing Corp., New York.
161 -66 shows that the calculated curves based on this modified model are in good agreement with the experimental ones. The thickness, concentration, and density of each layer were determined. From these results, the total amount of titanium was calculated to be 24 l.tg cm -2, a value that agrees well with that determined by chemical analysis. Analysis of heat-treated samples revealed that transition layers on the surface and interface had been eliminated; a thick, homogeneous silicide layer had been formed instead. The experimental results for the thin film sputtered with carbon-titanium, before heat treatment, are shown in Fig. 2-67. The reflection curve shows two critical angles. The small one is that of carbon and the large one that of titanium. The X-ray fluorescence profile detected the Ka line of iron. Although iron is an impurity, analysis must take its existence into consideration. Assuming a carbon-titanium two layered structure, it was found that the sample had a surface roughness of 50/~, a carbon layer density of 1.7 g cm -3, and a titanium silicide (65% Ti and 35% Si) layer with a density of 4.4 g cm-3. The density of the carbon layer was considerably smaller than that of graphite (2.26 g cm-3). However, as shown in Fig. 2-68, there is a significant difference between the experimental and calculated reflection curves in the vicinity of the critical angles. Therefore, it was necessary to once again incorporate transition layers into the model. The curve from the experimental results and the curve which resulted when the transition layers were incorporated in the model are shown in Fig. 2-69. This modification suggests that there are two high-density transition layers (carbon, p = 2.0; carbon, p = 1.7) near the surface. The total concentration of iron contained in each of the three
~,
TiKtx
FeK~ m~ = (t.24
= .
;> O
!
I
I
I
2
3
4
5
I
6
Glancing angle / mrad
I
7
2
I
3
I
4
I
5
I
6
I
7
Glancing angle / mrad
Fig. 2-67. Experimental results for the carbon and titanium sputtered sample without heat treatment. From Ref. [60], reprinted by permission of Plenum Publishing Corp., New York.
162 1.0
.~n-I
0.5
1
2
3
4
5
6
Glancing angle / m r a d Fig. 2-68. Comparison of the experimental reflection curve (bold line) with the calculated curve; the sample is assumed to be carbon ( 2 8 0 n m ) / Ti0.65Si0.35/ silicon substrate [61 ]. The carbon layer contains iron as an impurity. The values of t~and fl of the carbon layer are affected by iron. For the carbon layer t5= 3.45x10 -6, fl = 2.57x10 -8 and for the silicide layer t~= 8.46x10 -6, t = 3.57x10-7.
carbon layers was 2%, which is in good agreement with the value determined from the X-ray fluorescence intensity. The results of the 250~ heat treatment sample, shown in Fig. 2-70, indicate much steeper curves near the critical angles, in the reflection curve and in the Fe Ks fluorescence profile. This suggests that the two high-density transition layers previously mentioned have been eliminated during heat treatment. In the 750~ heat treatment sample shown in Fig. 2-71, the titanium fluorescence profile is similar in pattern to the iron fluorescence profile. These similar patterns point to the formation of a homogeneous monolayer on the silicon substrate surface. We have shown that measurements of the reflection curve and X-ray fluorescence profile at grazing incident angles provide an excellent method for analyzing thin films. The benefits of this method are that it is nondestructive, and that sample composition, thickness, density and elemental concentration can be determined. Although still used in very few studies of this kind, SR is expected to be widely employed in the near future.
163 Carbon
20nm
S = 4 . 1 4 x 10 ~ , f l = 4 . 1 0 x 10 -8 , p - 2 . 0 Carbon S = 3 . 4 7 x 1 0 -4, f l = 3 . 4 4 x l O 4, 0 = 1 . 7
20 nm
Carbon 260 nm
S = 3.13 x 10-6 , f l = 2 . 5 7 x 10 4 , p = 1.5
Titanium silicide t5 = 8.46 x 10 -6, fl = 3.57 x 10-7,/9 - 4.35
23 nm
Silicon substrate
1.0
o~,~
0.5
1
2
3
4
5
6
Glancing angle / mrad
Fig. 2-69. Comparison of the experimental reflection curve (bold line) with the calculated curve [61].
164
Ti Ko~ fluorescence profile ]
~ v...~
Reflection curve
I
"7.
I
I
Fe Ko~ fluorescence profile m
I
2
I
3
4
5
2
Glancing angle /mrad
3 4 6 7 Glancing angle / mrad
Fig. 2-70. Experimental results for the samples without heat treatment (bold line) and with heat treatment at 250~ From Ref. [60], reprinted by permission of Plenum Publishing Corp., New York.
~
TiKo~
.~,,I
e~
r~
O
3
I
I
4
I
I
5
i
i
6
I
Glancing angle / mrad Fig. 2-71. Comparison of the Ti Kcx fluorescence profile with the Fe Ko~ fluorescence profile using the 750~ heat-treated C / Ti / Si substrate sample. From Ref. [60], reprinted by permission of Plenum Publishing Corp., New York.
165
2.6. PROSPECTS FOR FUTURE DEVELOPMENT With the advent of a third generation high-brilliance synchrotron source, and further extensive use of insertion devices, we can expect further advances in X-ray fluorescence analysis. We will discuss two such prospects: bulk analysis and surface analysis. The former mainly uses monochromatic excitation XRF, and the latter is based on the total reflection of Xrays.
2.6.1. Bulk analysis
Heavy element analysis Since conventional X-ray methods using ordinary tube excitation cannot provide sufficiently high excitation energy, researchers have been forced to use L- or M-series X-rays to analyze lanthanoids and actinoids. Compared with K-series X-rays, these characteristic X-rays have an intensity at least one order of magnitude lower and suffer from considerable interference because of closely arranged spectral lines, which result because the X-rays have small energy level differences. Furthermore, the energy region where these spectral lines are observed includes the characteristic X-rays of common, smaller atomic number elements (the third and fourth period elements). This results in a complex spectrum and makes accurate analysis even more difficult. Generally speaking, higher energy analyte lines reduce interference because their excellent penetrating powers decrease absorption by a matrix. Also, since no naturally occurring elements emit L-series lines of more than 20 keV, use of K-series lines has great advantages for the analysis of elements heavier than rhodium, both in precision and in sensitivity. Uranium is a good example. The K absorption edge of this element is approximately 115.6 keV. Therefore, if it were possible to excite uranium using an X-ray source with a higher energy level than 115.6 keV, analysis of uranium with very little interference would be possible. Consider another example. The K absorption edge of neodymium, used in materials such as laser glass, is at about 43.6 keV. If it were possible to excite it with X-rays of more than 50 keV, sufficient excitation efficiency would be achieved to conduct analysis of its trace quantities. In fact, an analysis of rare earth elements with K-lines, using VEPP-4 at Novosibirsk, equipped with a high-energy ring (5 GeV), detected amounts lower than ppm [62].
XRF using soft X-ray excitation X-ray fluorescence of second period elements (superlight elements) causes the release of a very small number of photons, compared with the number of photoelectrons and Auger
166 electrons observed. Also, the energy required for them to fluoresce is very low. These characteristics pose difficult problems for fluorescence measurement which uses an ordinary X-ray optical system. However, if the optical system is improved, and radiation from a large scale ring and an undulator combination is used as an excitation source, it will make the system sensitive enough for bulk analysis of these elements. This was tried at the Photon Factory, where an experiment has been reported using the undulator as the excitation source and a synthetic multilayer as the optical element [63]. Absolute (standardless) method The energy tunability and excellent collimation of SR are indispensable for accurate elucidation of the excitation and emission mechanisms of X-ray fluorescence, and for clarifying the interactions between analyte lines and any spectral lines emitted by elements other than analytes. Development of these analysis techniques will open up the possibility of an absolute method: i.e., a quantitative technique that requires no reference standard. When it is freed from reference standards, XRF will not be affected by the precision and accuracy of reference samples which have to be standardized by other methods such as chemical analysis. This will permit not only highly reliable ultratrace analysis, but also highly accurate measurements of the stoichiometric relationships of unknown substances. An example of analysis without standard references, based on the characteristics of SR, is a study by Bowen et al. [64]. They determined the concentration of As contained in a silicon sample ion-implanted with As, simply by measuring As and Si X-ray fluorescence intensities of the sample. They assumed a Gaussian distribution for the As concentration, and based the quantitative analysis on fluorescence yields and absorption coefficients available in the literature.
2.6.2. Surface analysis Excitation sources with higher brilliance, and improved measuring equipment and optical systems, will certainly combine to yield determination limits in the order of ppt (10-12 g g-l) and femtogram quantities (10 --15 g) using TXRF. As the use of SR increases, the structural analysis of thin films as described in Section 2.5 will also be employed to evaluate the surfaces and interfaces of various advanced materials. Recently, the X-ray standing wave method has received considerable attention as a total reflection surface analysis technique. It has been found to be useful for determining the structures of ultrathin organic films [65] and diffuse layers on liquid-solid interfaces [66]. This method is based on the phenomenon of diffraction and the accompanying oscillations in X-ray fluorescence intensity. In experiments, the angular dependence of the fluorescence intensity is measured and analyzed. Thus, depth profile analysis using X-ray standing waves has provided an experimental means of researching interfaces, an area that was previously only investigated theoretically.
167 As discussed above, the use of SR as an excitation source is creating a new range of possibilities. XRF, even itself, has made analysis more sensitive and has helped in the development of structural analysis techniques. In the future, SRXRF will provide more useful information for the characterization of a wide range of advanced materials.
REFERENCES
1. C. J. Sparks, Jr., "Synchrotron Radiation Research", ed. H. Winick and S. Doniach, Chap. 14, p. 459, Plenum Press, New York, 1980. 2. V. Baryshev, G. Kulipanov and A. Skrinsky, "Handbook on Synchrotron Radiation ", ed. G. S. Brown and D.E. Moncton, Vol. 3, Chap. 16, p. 639, North-Holland, Amsterdam, 1991. 3. A. Iida and Y. Gohshi, "Handbook on Synchrotron Radiation ", ed. S. Ebashi, M. Koch and E. Rubenstein, Vol. 4, Chap. 9, p. 307, North-Holland, Amsterdam, 1991. 4. P. Horowitz and J. A. Howell, Science (Washington, D.C.), 178, 608 (1972). 5. C. J. Sparks, Jr., S. Raman, H. L. Yakel, R. V. Gentry and M. O. Krause, Phys. Rev. Lett., 38, 205 (1977). 6. C. J. Sparks, Jr., S. Raman, E. Ricci, R. V. Gentry and M. O. Krause, Phys. Rev. Lett., 40, 507 (1978). 7. J. V. Gilfrich, E. F. Skelton, S. B. Qadri, J. P. Kirkland and D. J. Nagel, Anal. Chem., 55, 187 (1983). 8. A. L. Hanson, H. W. Kraner, K. W. Jones, B. M. Gordon, R. E. Mills and J. R. Chen, IEEE Trans. Nucl. Sci., NS-30, 1339 (1983). 9. A. Kn6chel, W. Petersen and G. Tolkiehn, Nucl. Instrum. Methods Phys. Res., 208, 659 (1983). 10. A. J. J. Bos, R. D. Vis, H. Verheul, M. Prins, S. T. Davies, D. K. Bowen, J. Makjani6 and V. Valkovi6, Nucl. Instrum. Methods Phys. Res., Sect. B, B3, 232 (1984). 11. A. Iida, K. Sakurai, T. Matsushita and Y. Gohshi, Nucl. Instrum. Methods Phys. Res., 228, 556 (1985). 12. B. M. Gordon, Nucl. Instrum. Methods Phys. Res., 204, 223 (1982). 13. P. W. J. M. Boumans, P. Wobrauschek and H. Aiginger, (ed.), Proceedings of the Third Workshop on TXRF, Vienna, May 1990, Spectrochim. Acta, Part B, 46B, 1313-1436 (1991). 14. P. W. J. M. Boumans and A. Prange, (ed.), Proceedings of the Fourth Workshop on TXRF, Geesthacht, May 1992, Spectrochim. Acta, Part B, 48B, 107 - 299 (1993). 15. Y. Yoneda and T. Horiuchi, Rev. Sci. Instrum., 42, 1069 (1971). 16. A. Iida, A. Yoshinaga, K. Sakurai and Y. Gohshi, Anal. Chem., 58, 394 (1986). 17. A. Iida, K. Sakurai, A. Yoshinaga and Y. Gohshi, Nucl. Instrum. Methods Phys. Res., Sect. A, A246, 736 (1986).
168 18. H. Hashimoto, H. Nishioji, H. Saisho and A. Iida, Adv. X-Ray Chem. Anal. Jpn., 20, 143 (1989). 19. B. M. Lairson and D. H Bilderback, Nucl. Instrum. Methods Phys. Res., 195, 79 (1982). 20. A. Iida, T. Matsushita and Y. Gohshi, Nucl. Instrum. Methods Phys. Res., Sect. A, A235, 597 (1985). 21. B. W. Batterman and H. Cole, Rev. Mod. Phys., 36, 681 (1964). 22. T. Matsushita and H. Hashizume, "Handbook on Synchrotron Radiation ", ed. E.-E. Koch, Vol. la, Chap. 4, p. 273, North-Holland, Amsterdam, 1983. 23. H. Oyanagi, "Photon Factory Activity Report 1989", KEK, Tsukuba, 1990, p. I-4. 24. C. J. Sparks, Jr., B. S. Bode and J. B. Hastings, Nucl. Instrum. Methods, 172, 237 (1980). 25. C. J. Sparks, Jr., G. E. Ice, J. Wong and B. W. Batterman, Nucl. Instrum. Methods Phys. Res., 194, 73 (1982). 26. B. W. Batterman and L. Berman, Nucl. Instrum. Methods Phys. Res., 208, 327 (1983). 27. See, for example, H. Takenaka, Y. Muramatsu, H. Takaoka, Y. Ishii and H. Hashizume, Rev. Sci. Instrum., 60, 2018 (1989). 28. T. Matsushita, T. Ishikawa and H. Oyanagi, Nucl. Instrum. Methods Phys. Res., Sect. A, A246, 377 (1986). 29. H. Winick, "Synchrotron Radiation Research", ed. H. Winick and S. Doniach, Chap. 2, p. 11, Plenum Press, New York, 1980. 30. H. Saisho and H. Hashimoto, "Trace Analysis (in Japanese) ", ed. K. Kurosaki and F. Konishi, Chap. 9, p. 245, Kodansha, Tokyo, 1988. 31. H. Saisho, Trends Anal. Chem., 8, 209 (1989). 32. W. H. McMaster, N. Kerr Del Grande, J. H. Mallett and J. H. Hubbell, "Compilation of X-Ray Cross Sections", UCRL-50174 Sec. II, Rev. 1, University of California, Livermore, CA, 1969. 33. S. Sasaki, "X-Ray Absorption Coefficients of the Elements (Li to Bi, U)", KEK Report 90-16, November 1990, M/D, KEK, Tsukuba, 1990. 34. W. Bambynek, B. Crasemann, R. W. Fink, H.-U. Freund, H. Mark, C. D. Swift, R. E. Price and P. V. Rao, Rev. Mod. Phys., 44, 716 (1972). 35. A. L. Hanson, Nucl. Instrum. Methods Phys. Res., Sect. A, A243, 583 (1986). 36. F. S. Goulding and J. M. Jaklevic, Nucl. Instrum. Methods, 142, 323 (1977). 37. L. A. Cunie, Anal. Chem., 40, 586 (1968). 38. R. D. Giauque, J. M. Jaklevic and A. C. Thompson, Anal. Chem., 58, 940 (1986). 39. A. Kn6chel, W. Petersen, G. Tolkiehen, Anal. Chim. Acta, 173, 105 (1985). 40. K. W. Jones, B. M. Gordon, A.L. Hanson, J.B. Hastings, M.R. Howells, H.W. Kraner and J. R. Chen, Nucl. Instrum. Methods Phys. Res., Sect. B, B3, 225 (1984). 41. S.R. Sutton, M. L. Rivers and J. V. Smith, Anal. Chem., 58, 2167 (1986). 42. J. M. Jaklevic, R. D. Giauque and A. C. Thompson, Anal. Chem., 60, 482 (1988). 43. M. Born and E. Wolf, "Principles of Optics", Pergamon Press, New York, 1980.
169 44. P. A. Pella and R. C. Dobbyn, Anal. Chem., 60, 684 (1988). 45. H. Hashimoto, Y. Iida, H. Saisho and H. Nishioji, Anal. Sci. [Supplement], 7, 577 (1991). 46. C. J. Sparks, Jr., Adv. X-Ray Anal., 19, 19 (1976). 47. A. Iida, K. Sakurai and Y. Gohshi, Adv. X-Ray Anal., 31, 487 (1988). 48. J. M. Bloch, M. Sansone, F.Rondelez, D. G. Peiffer, P. Pincus, M. W. Kim and P.M. Eisenberger, Phys. Rev. Lett., 54, 1039 (1985). 49. H. Kiessig, Ann. Phys. (N.Y.), 10, 715 (1931). 50. L. G. Parratt, Phys. Rev., 95, 359 (1954). 51. L. N6vot and P. Croce, Rev. Phys. Appl., 15, 761 (1980). 52. B. Vidal and P. Vincent, Appl. Opt., 23, 1794 (1984). 53. A. Kr61, C. J. Sher and Y. H. Kao, Phys. Rev. B, 38: Condens. Matter, 8579 (1988). 54. T. C. Huang and W. Parrish, Adv. X-Ray Anal., 35, 137 (1992). 55. K. Sakurai and A. Iida, Jpn. J. Appl. Phys., 31, L113 (1992). 56. M. Gentry, J. Durand, M. Erman, J. B. Theeten, L. N6vot and B. Pardo, Appl. Surf. Sci., 44, 309 (1990). 57. A. Kr61, C. J. Sher, D. R. Storch, S. C. Woronick, Y. H. Kao, L. L. Chang and H. Munekata, Surf. Sci., 228, 108 (1990). 58. A. Kr61, H. Resat, C.J. Sher, S. C. Woronick, W. Ng, Y. H. Kao, T. L. Cole, A. K. Green, C. K. Lowe-Ma, T.-W. Nee and V. Rehn, J. Appl. Phys., 69, 949 (1991). 59. S. M. Heald, H. Chen and J. M. Tranquada, Phys. Rev. B, 38: Condens. Matter, 1016 (1988). 60. H. Hashimoto, H. Nishioji and H. Saisho, Adv. X-Ray Anal., 35, 807(1992). 61. H. Hashimoto, H. Nishioji and H. Saisho, "Proceedings of the International Conference on Materials and Process Characterization for VLSI, 1991(ICMPC "91)", ed. X.F. Zong, Y. Y. Wang and X. Y. Gu, p. 592, National Microanalysis Center for Microelectronic Materials & Devices, Shanghai, October 1991. 62. V. B. Baryshev, A.E. Gilbert, O.A. Kozmenko, G.N. Kulipanov and K.V. Zolotarev, Nucl. Instrum. Methods Phys. Res., Sect. A, A261, 272 (1987). 63. A. Iida, Y. Gohshi and H. Maezawa, Adv. X-Ray Anal., 29, 427 (1986). 64. D. K. Bowen, S. T. Davies and T. Ambridge, J. Appl. Phys., 58, 260 (1985). 65. M. J. Bedzyk, G. M. Bommarito and J.S. Schildkraut, Phys. Rev. Lett., 62, 1376 (1989). 66. M.J. Bedzyk, G. M. Bommarito, M. Caffrey and T. L. Penner, Science (Washington, D.C.), 248, 52 (1990).
This Page Intentionally Left Blank
Applications of Synchrotron Radiation to Materials Analysis H. Saisho and Y. Gohshi (Editors) 9 1996 Elsevier Science B.V. All rights reserved.
171
CHAPTER 3
M I C R O B E A M AND C H E M I C A L STATE ANALYSIS Shinjiro HAYAKAWA and Yohichi GOHSHI D e p a r t m e n t of A p p l i e d Chemistry, Faculty of Engineering, University of T o k y o , 7-3-1, H o n g o , B u n k y o , T o k y o 113, J a p a n 3.1. I N T R O D U C T I O N Since the discovery of X-rays, X-ray microscopy has received great attentions because of its potential in realizing the highest spatial resolution of all the types of light microscopes. A number of types of X-ray microscopes have been designed since the 1950s [1,2]. However, there have been few attempts to make them, and the performance of these microprobes has been poor because the requirements for the optical elements were far beyond the technologies available at the time. Most of the X-ray microscopes which use a conventional X-ray source have been of the imaging type ( the projection type ) because the acceptance, or aperture, of the grazing-incidence optics is too small to realize the small intense X-ray beam which is needed as a probe beam for a scanning X-ray microscope or an X-ray microprobe. The advent of synchrotron radiation (SR) as a light source for use in materials science has changed the situation. Horowitz and Howell were the first to fabricate a scanning type SR Xray microscope with analytical capabilities [3,4]. Figure 3-1 shows a schematic layout of their microscope. Because of the small divergence of the SR, X-ray focusing optics could be used effectively to achieve the photon flux density. Fabrication of an ellipsoidal or a toroidal figure was difficult, so a bent cylindrical mirror was used instead [5]. The size of the resultant beam spot was 1 mm x 2mm in the vertical and horizontal directions. To realize sub-mm spatial resolution, a small pinhole of 2 ~tm diameter was placed in front of the sample. The advantage of the scanning X-ray microscope is its ability to detect various types of signals from a sample, and X-ray images were demonstrated with transmitted X-rays and fluorescence X-rays. Although the idea of the analytical X-ray microprobe was excellent, its analytical capability was limited to elemental analysis because the microprobe used "white" SR. Furthermore, there were difficulties in improving its spatial resolution of the X-ray microprobe. There have been great improvements in the spatial resolutions of electron and ion microscopes as a
172 result of progress in the focusing of charged particles. Because electrons and ions can be used as primary beams for X-ray emission analysis, an electron probe microanalyzer with an X-ray detection system can be regarded as an X-ray microanalyzer. The importance of the SR X-ray microprobe has been recognized widely since Sparks demonstrated the feasibility of using monochromatized SR X-rays for X-ray fluorescence analysis, as described in the preceding Chapter. Sparks has calculated the expected performance of the SR X-ray microprobe in terms of the trace sensitivity. The heat load on a sample was also compared for SR X-ray-, electron-, and proton microprobes [6]. Recently, several types of SR X-ray microprobes have been realized. They are used in materials science, and the advantages of SR X-ray microscopy are well recognized. These advantages are not limited to their trace-sensitivity but also apply in
chemical state analysis. Moreover, the
importance of the X-ray microprobe is widely understood as being a fundamental excitation technique for various X-ray analyses. In this Chapter, the design considerations and reported performance of the analytical SR X-ray microprobes are reviewed. In addition to the analytical X-ray microprobe, which mainly employs hard X-rays, there is great progress with
soft-X-
ray microscopes for the observation of biological sections. For information on the soft-X-ray microscope the reader is referred to recent conference proceedings[7-9].
ctron synchrotron
X,Y,Z mechanical stage l,,,,,,Sampleholder
\
~~
Vacuum
Air
" / ~ l"/ . ~ " ~
Gas-filled proportionalcounter
Synchrotron ~ . ~ ~ ~ Beam stop radiation ~ 4 ~]~~.__ X-ray condensing mirror 10 #m | beryllium | window " Pulse amplifier Pinhole Energy discriminator in lOOmmgold
X,Y transducer Fig. 3-1.
0
Oscilloscope display
A prototype of a scanning X-ray microscope by Horowitz and Howell [3].
173
3.2.
X-RAY FOCUSING OPTICS
In this Section, the background for the design of SR X-ray focusing optics will be described. Since the 1950s, there have been several important papers about X-ray imageforming optics. Their most important characteristic is the beam size which is obtainable. However, in the analytical sense, the obtainable photon flux or the gain in photon flux density also have great importance.
3.2.1.
X-ray optical elements
The X-ray optical elements and their applicable energy ranges are shown in Table 3-1. For the hard X-ray region, the optical elements are limited to crystals, multilayers and totalreflection mirrors. Crystals and multilayers are used with glancing angles which satisfy the Bragg condition. Total-reflection mirrors are used with glancing angles less than 1 degree for hard X-rays. Although the difference in the glancing angles required for the total-reflection mirror and the crystals and multilayers is large, the optical systems composed of these optical elements use the grazing incidence geometry. Table 3-1 X-ray optical elements and applicable energy ranges which are commonly used. Optical element
Function
Applicable energy range
Total-reflection mirror
Reflective
~ 20 keV
Multilayer
Diffractive
~ 20 keV
Crystals
Diffractive
~ 60 keV
Diffraction grating
Diffractive
~ 1 keV
Zone plate
Diffractive
~ 1 keV a
a Recently, several attempts have been made to fabricate hard-X-ray zone plates: fairly good performance has been reported [ 10,11 ].
174
3.2.2. Grazing incidence optics. The parameters for grazing incidence optics are shown in Fig. 3-2. The optical axis lies between the source S and the image I. The typical reflecting point is represented as P. The plane including S, P and I is a meridional plane and the plane normal to this is a sagittal plane. The radius of curvature of the reflector should be different for the meridional plane and the sagittal plane when focusing the divergence from a point source with grazing-incidence optics. With the distance between SP and PI, the famous mirror formula describes the radii of curvatures in the meridional and the sagittal planes.
1/FI +I/F2= I/f
(3-1)
f=Rmsin O/2=Rs/(2sin 0)
(3-2)
The magnification of the optics is defined as
M=F2/Fl =sina/sina' =a/a'
(3-3)
By considering the nature of an ellipsoid, one can see that rays from one of the foci are reflected and converged into another Iocus. It is evident that the ellipsoidal figure satisfies the mirror formula at all the points on the surface. Moreover, the sum of distances from the foci is constant at all the points on the ellipsoidal surface. Therefore the ellipsoidal mirror is ideal for a point source, for both geometrical and wave optics. When one is designing practical X-ray-focusing optics, one should consider a real source having finite dimensions. One of the practical ways to evaluate the performance of the optics is to use the ray-tracing method. The focused beam spot is expressed in terms of the sum of intersections between rays and the screen at the image plane. Another way is to
use the
theoretical descriptions which are classical but are suited to comparisons of optical systems. In this method it is helpful to consider the point-spreading functions for point sources at on-axis and off-axis positions. In the next Section, the performance of the optics is discussed, along with the theoretical descriptions.
175
$ -1
$ FI
F1
2 ~..~1
e
I
I p
m
Fig. 3-2.
L s
Parameters for a grazing incidence optical system: S(xs,Ys), I(xi, Yi) refer to coordinates in the source plane and image plane, respectively; Lm, Ls are mirror lengths in the meridional plane and sagittal plane; Rm, Rs are the radii of curvature in the meridional plane and sagittal plane; 0 is the glancing angle; FI=S 1/cosa,
F2=S2/cosa'
3.2.3. Image formation
of a point source
An ellipsoidal surface is ideal for use with a point source. However, the aspherical figure is difficult to fabricate. Therefore a substitutional configuration is often employed. One methtxt uses a toroidally shaped mirror which satisfies the mirror formula in its central part. Another uses a Kirkpatrick-Baez mirror [12] which consists of two concave (or elliptical ) mirrors lk~r
176 vertical and horizontal divergence, respectively (Fig. 3-3). With the concave mirror the beam size is determined by the spherical aberration [ 12]. Figure 3-4 shows a cross section of a concave mirror in the meridional plane. Points S and I are on the so-called Rowland circle. A ray SOI shows a principal ray. As other rays from a point source S are not converging into point I, blurring of the image occurs in the image plane. The size of the image in the meridional plane, Sm,
is represented by the following
expressions.
Fig. 3-3.
Kirkpatrick and Baez mirror [12]
jt
jO
i s
i
/ i
/
P
i J J~
H
!
I
Fig. 3-4.
i
ss ss
Js
,I',
9 9 9
I
I"
i J i
._-.-.--- "--.--re "," L,""
,,."F ~ / /
91 j S
s S
O
(Left) Reflection of X-rays from a spherical mirror at small glancing angles. R is the radius of a circular reflector. (Right) Details of ray intersections at the image of a point source formed by a spherical mirror illuminated at a small glancing angle [12].
177
Sm=-3/2Ry2g(M)
(3-4)
where
(3-5)
g(M)={( l+2a)M 2-1 }/(M+ 1)
a=~,/0
M=F2/F1 In focusing optics whose magnification is far less than unity,
Sm
can be regarded as
Sm=_3/2R.~2 If we consider a point source and a concave mirror of magnification M=I/10
(3-6) with a
glancing angle of 8.4 mrad placed at a distance of 10 m from the source, the radius of the curvature R must be 216 m. When the dimension of the mirror is 24 cm in the meridional plane the focused beam has a finite size of 0.4 mm in the meridional plane even with the point source. To reduce the spherical aberration while maintaining the acceptance, the glancing angle must be larger to reduce the effective mirror size in the meridional plane.
3.2.4. I m a g e f o r m a t i o n
of a real
source
In considering the performance of the optical system with a real source of finite dimensions, it is most convenient to think about the image of a point source placed at an off-axis position. When the effects of an off-axis point can be neglected, the optical system should obey Abbe's famous criterion, which is sin a=sin a'= con st For grazing incidence optics,
(3-7)
Abbe's criterion should be satisfied independently, both in the
meridional and sagittal planes. Figure 3-5 demonstrates that the Abbe's criterion cannot be satisfied with single reflector and that it is easier to realize the criterion when double reflectors are employed. Abbe's criterion suggests that the ellipsoidal mirror has limitations in covering a large field of the view. The Wolter mirror was proposed in 1952 to overcome this limitation [13,141.
178
S
$
I
Fig. 3-5.
I
Abbe's sine theorem. A comparison between single (Left) and double (Right) reflectors.
3.2.5. Ellipsoidal and W o l t e r m i r r o r s The schematics of ellipsoidal and Wolter (type I) mirrors are shown in Fig. 3-6. For an optical system having axial symmetry rays from a point source are equivalent wherever the source is on the optical axis. To compare the performance of the two types of mirrors, traces are shown for two rays from the displaced point source in the meridional plane. The meridional ray crosses the image plane at the point Im and the sagittal ray crosses at the point Is. For the ellipsoidal mirror, Im and Is come on opposite sides of the optical axis. With the first order approximation about 0, the distance between two points can be expressed by
Imls=2Md
(3-8)
where M is the magnification of the ellipsoidal mirror and d is the displacement of the point source S 'from the optical axis. For the Wolter mirror, Im and Is fall in the same position. The resultant images of the point source with rays of various directions are summarized in Fi g. 3-7. When the point source is located on the optical axis the resultant image also becomes a point shape for both cases. However, when the point source is displaced the resultant images are quite different for the ellipsoidal and the Wolter mirrors. With the ellipsoidal mirror the resultant image becomes an arc of radius Aid. The length of the arc is determined by the portion of the annular aperture as indicated in Fig. 3-2. Using a Wolter mirror of ideal shape the resultant image is a point shape. Considering the real source of finite dimensions, the image obtained with the ellipsoidal mirror becomes circular when more than half of the annular aperture is used. The radius of the image is determined by the maximum displacement of the source from the optical axis. The
179 Wolter mirror provides a uniform transformation, neglecting the higher order aberrations. The results show that the Wolter mirror is not as sensitive to misalignment of the optical axis as is the ellipsoidal mirror.
80 v
~
~v
Is
z-~ SOURCE ~
ELLIPSOIDAL
~IMAGEr.....
80
S
z
j
Fig. 3-6.
~
I ~~ SOURCE
I~
ELLIPSOIDAL
a'
MAGE HYPERBOLOIDAL
A schematic representation of, (a) ellipsoidal and, (b) Wolter mirrors. To show the characteristics of these mirrors, meridional ( in plane) and sagittal (out of plane) rays from a point source at the focus (S) and those from a displaced source (S') are
shown in the Figures.
180
SOURCE
IMAGE Ellipsoidal Wolter
y x
k Y
Y
' ' "
x
Fig. 3-7.
•
I
l
l
"=
x
Comparisons of images between ellipsoidal and Wolter mirrors. From top to bottom, a point source on the axis, a point source off the axis, and a real source of finite dimensions. ~brepresents the portion of the annular aperture as indicated in Fig. 3-2.
3.2.6. Expected photon flux with an X-ray focusing system For an analytical X-ray microprobe, both the spatial resolution and the sensitivity are important. In order to estimate the photon flux expected with an X-ray focusing system the brilliance of the source, B, the acceptance of the optics, and the reflectivity (or efficiency) of
181
the optics should be considered. The acceptance can be defined as the divergence from the source which can be received with the optics. If we consider the grazing-incidence mirror shown in Figure 3-2, the vertical acceptance qJv can be expressed in terms of the mirror length in the meridional plane (Lm) and 0, as
~Pv=LmsinO/F1
(3-9)
For the ellipsoidal mirror, the horizontal acceptance ~Ph at the center of the mirror can be expressed in terms of Rs and the half-width of the annular aperture, AR, as ~Ph=2V'((Rs+AR)2-Rs2)/F1
(3-10)
where
AR=Lmsin O/2
(3-11)
By considering the monochromatic X-rays of energy E from a synchrotron radiation source of brilliance B, the expected incident photon flux to the optical system in a small divergence from a source of unit dimensions can be expressed as
AP(E) =Ba ~v k Wh
(3-12)
The photon flux after the optical system can be given in terms of the reflectivity at the mirror, R(E, 0), and the absorption through the optical path, A(E). Therefore, the photon flux at the focus can be expressed as P(E)=A(E) ~ ~ ~ S BR(E,O) d~Pvd~Phdxdy
(3-~3)
If we neglect the angular distribution of the brilliance, the photon flux can be shown to be
P(E) =A (E)B ~ crxcryR (E, O)~Pv~Ph
(3-14)
where Ox and cry are the source size in the x and y directions. With a distance L between the source and the focus, the approximate beam size without the focusing system is ~pvL and ~PhL in the vertical and horizontal directions, respectively. Therefore, the intensity gain with the optical system will be defined by
182
G(E)=L2R(E, O)~Pv~h/(S x' Sy ') where
Sx'
and
(3-15)
Sy' represent the beam size at the focus. In general, the intensity gain is largely
affected by the acceptance of the optical system. Therefore, a larger glancing angle is advantageous not only for the spherical aberration but also for the photon flux.
3.3. 3.3.1.
EXAMPLES
OF X - R A Y F O C U S I N G
SYSTEMS
Introduction
Characteristics of most of the X-ray focusing systems currently employed for X-ray fluorescence microprobes are shown in Table 3-2. For the soft X-ray region there are several types of optical systems which are successfully used for photoelectron microprobes.
These
are mentioned in the following Sections. Most of optical systems are classified into two categories; reflective optics and diffractive optics. A combination of reflective focusing optics and a monochromator can produce an energy tunable X-ray microbeam while maintaining the beam position. However, diffractive focusing optics can usually provide a higher photon flux than can be obtained with the reflective optics because they can perform both as monochromators and focusing devices of larger acceptance. 3.3.2.
Reflective
optics
Figure 3-8 shows examples of reflective optics. By using a Wolter mirror a micron-sized hard X-ray beam was first realized. However, effects of the surface roughness were also indicated by the difference in beam size in the sagittal plane and meridional plane. In the Kirkpatrick-Baez (K-B) mirror systems, crossed elliptical mirrors are used instead of the concave mirrors, to eliminate spherical aberration. Although a spatial resolution of several microns has been obtained with the Wolter and K-B mirrors,
the fabrication of large
aspherical mirrors is still limited by technical difficulties. Therefore, the photon flux with these optical systems is not sufficient for various types of analytical applications. In order to optimize both the spatial resolution and the trace sensitivity a combination of the focusing optics with the pinhole is employed, as was first demonstrated by Horowitz and Howell [3]. Figure 3-8(c) shows a microprobe system with an ellipsoidal mirror. In this case, the surface-
183 finishing of the mirror was carried out by skilled technicians to achieve sufficient reflectivity but at the sacrifice of the accurate contour. Table 3-2 X-ray focusing systems for X-ray fluorescence microprobes in the hard X-ray region. DCM, double crystal monochromator; CCM, channel cut monochromator; SMM, synthetic multilayer monochromator Source Optics
Beam size
Photon energy
Refs.
PF Wolter mirror
1.6 ~tm x 34 ~tm
K-B mirror
3.8 ~tm x 1.7 ~tm
K-B mirror
3.0
gm x 4.2
~tm
5.5 gm x 6.1 gm Ellipsoidal mirror Zone plate
10-200 ~tm with a pinhole 6.5 ~tm x 7.7 ~tm
8keV tunable(DCM) 5.4 keV tunable(CCM) 10.5 keV tunable(DCM) 12.6keV tunable(SMM) 4-20 keV tunable(DCM) 8keV
15, 16 17, 18 19
20,21 10
NSLS
Ellipsoidal mirror Multilayer coated K-B mirror
5 ~tm x 5 ~tm
10keV
22 23,24
Curved Si crystal
10 ~tm x 20 ~xm
15keV
25
20 keV
26
8.3keV
27 28
SRS
VEPP-3 Pyrolytic graphite LURE Bragg-Fresnel (K-B or Elliptical)
3.3.3.
20 gm
Diffractive optics
Typical examples of diffractive optics are shown in Fig. 3-9. Following the invention of the sagittal focusing monochromator [29] most proposed microprobe optics have included bent crystals of variable radius. However, it is difficult in practice to realize a spatial resolution of less than several tens of microns with these optics, and the bent crystal of fixed radius is
184 employed instead. Owing to the fixed radius, the incident X-ray energy is not tunable. However, a 15 keV microprobe shown in Fig 3-9(a) is successfully used for XRF trace element analysis.
M=1/13
a
M=1/20
SR
2.45m
F2
~:: SLtT . I CONDENSER MIRRO~~~
FOCUSING
MIRROR
PINHOLE Ta 60~m~
"(i
11.2m/~' g
MONOCHROMATOR M~
F
Mz
b
C
I
Sample
Pinhole +Beam monitor ~ ~ J ~ Ionization chamber Ellipsoidal mirror
Si(Li)
Monochromator SR Fig. 3-8.
X-ray focusing systems wit h reflective optics with:
(a), tandem Wolter
mirrors[ 16]" (b) Kirkpatrick-Baez mirrors [18]" (c) an ellipsoidal mirror [20].
185
a Synchrotron source (white radiation)
M1
Multilayer coated mirrors Solid state Si(Li)detector M2 Sampl ~ ~ spot ~ ~ Focal ,.,
Fluorescent x-rays
Scanning stage
b
Ion
Storage Sourceslit ring
chamber Si(Li) Anti-scat. i Object detector slit ~1 ~[ slit [~ ~~~,J~] ~ ~
t
image plate
Toroid Si(111) S.C
C
lit S"
F"~""~ [~rPinhole
, ~ ' ~
Zone plate
"~'*~~ !~'~~ Monochromator X-ray d
Slit 7
10 1. Inputslit 2. BFMFE 1 3. BFMFE 1 stage 4. Axisof rotation 5. Goniometer 6.7. Slits 8. BFMFE2 9. BFMFE2stage 10. Recording plate
Fig. 3-9.
X-ray focusing systems with diffractive optics with: (a) multilayer coated K-B mirrors[23]" (b) a bent Si(111) crystal[25]" (c) a zone plate[10]" (d) Bragg-Fresnel lens (K-B) [27]
186 Figure 3-9(a) shows a multilayer coated K-B mirror system. The coating of multilayers on the mirror surface limits the applicable energy range. However, it can make the glancing angle much higher than achieved with the total-reflection mirror when X-rays of the same energy are focused. As mentioned previously, the larger glancing angle is advantageous both for the spherical aberration and the acceptance of the optics. Figure 3-9(c) shows an optical system with a zone plate. Despite the successful fabrication of zone plates for the soft-X-ray region, using lithographic techniques, it is difficult to fabricate zone plates for hard X-rays because of the rays' large penetration. In order to obtain a zone plate of sufficient stopping power, a high aspect ratio is required. Therefore a novel technique was invented to replace the conventional lithographic techniques. Saitoh et al. first fabricated a hard X-ray zone plate using the sputtering method [10]. Layers of C and WSi2 were alternately sputtered around a fine Au wire of 18 ~tm diameter. The performance of the zone plate was evaluated with 8 keV X-rays, and a focused beam spot of 6.5 ~tna by 7.7 ~tm in the vertical and horizontal directions was realized. Recently, another hard-X-ray zone plate (phase zone plate) has been reported, which can produce a focused beam spot of 3 ~tm by 8 ~tm in the vertical and horizontal directions, respectively [ 11]. A recent advance in X-ray optics is the Bragg-Fresnel lens (BFL) which uses a combination of the Bragg reflection and Fresnel zone. Since the first report of a linear Bragg-Fresnel lens [30], two types of focusing system have been proposed. One is the K-B configuration with a crossed linear BFL, and another uses an elliptical BFL. An X-ray fluorescence microprobe with the elliptical BFL is now in operation at LURE [28].
3.4. C H E M I C A L S P E C I A T I O N USING SR 3.4.1.
Introduction
Several kinds of X-ray analyses can provide chemical state information; X-ray photoelectron spectroscopy
(XPS),
Auger
electron
spectroscopy
(AES),
X-ray
fluorescence
spectroscopy(XFS) and X-ray absorption spectroscopy(XAS). Of these, XPS, AES and XFS are the popular analytical methods with conventional X-ray sources. Therefore, it is not necessary to describe their principles in this Section. The use of XAS has become popular since the advent of SR as an X-ray source having a continuum energy distribution. Spectral structures which appear around the absorption edge energy in X-ray absorption spectra are called X-ray absorption fine structure (XAFS), and both chemical state information and local structural information can be obtained from XAFS.
187 Various combinations of SR X-ray microprobe and spectrochemical techniques have the promise of becoming powerful methods for the characterization of advanced materials whose function is strongly related to the chemical state of a local area in a material. Recently, several reports have appeared of X-ray spectrochemical analysis with spatial resolution. In this Section,
X-ray spectroscopies for chemical state analyses are
briefly reviewed.
The
advantages of energy tunability will also be discussed in order to point out the potential of Xray spectrochemical analysis with an energy-tunable X-ray microprobe.
3.4.2. Chemical speciation utilizing X-ray absorption fine structure The chemical states of X-ray absorbing atoms are reflected in the fine structures of the Xray absorption spectra. A detailed analysis of X-ray absorption near-edge structure (XANES) reveals the electronic structures of an element of interest, and the extended X-ray absorption fine structure (EXAFS) is used to obtain local structural information on the element of interest -i.e., the nearest-neighbor distance and coordination numbers. XAFS spectra can be used for detailed analysis for revealing the chemical state of unknown materials and as finger prints for the identification of chemical species. In order to obtain XAFS spectra one may use several signals from a sample: transmitted Xrays, fluorescent X-rays, and Auger or secondary electrons. The XRF detection becomes advantageous in the following two cases. The first case is when the element of interest is a minor component or when the sample is too thin for measurement of XAFS spectra of sufficient S/N by the transmission method. The second case is when an XAFS spectrum is measured from a small region of interest in a heterogeneous sample and the absorption of the sample is not always in the appropriate range for transmission measurements. Figure 3-10 shows XANES spectra of various oxides [30].
Incident SR X-rays were
monochromatized with a Si(111) double crystal monochromator, and fluorescence detection was employed using a Si(Li) detector. The first inflection point of the spectrum from the pure metal is set to be relative zero. Figure 3-11 shows the relationship between the absorption edge energies measured using the transmission method and the XRF detection method. A fairly good correlation was obtained.
188
23
CuK,-'/ /! ~.','~Cu2C
;s
FeO~;~ Fe304
03
I!
," "',,
Ni
MnO--~,!].-~-Mn203 -./Mn02
x
i
-20
0 20 40 X-ray Energy / eV
-20
0
20
40
X-rag Energy ! eV
Fig. 3-10 XANES spectra of various oxides with the XRF detection method [31 ]. .....
~
o f
l~0I
Fe203j~U' L Fe304D" K4Fe(CN)6 FeO /'O'FeCI3 I o,/ I FeSO4 P" I FeFsS,,.,O,'O FeCI2
1 F
ul
U
I
0" LII
i
i
I
i
I
0 Fig. 3-11.
I
,.-Y
f
i i
I
i
I
i
!
i
[
i
i
5
!
i
i
i
i
i
l
i
i
i
i
10
i
i
i
l
!
l
i
Edge Energy(F)/eV
i
!
l
i
I
!
15
Comparisons of the absorption edges of various iron compounds: (F) and (T) refer to the fluorescence and transmission methods, respectively.
189 Although XRF detection becomes advantageous with the X-ray microprobe,
spectral
distortions caused by self-absorption effects should be considered when the element of interest is a major component in a sample. Figure 3-12 shows Fe K-edge XANES spectra from a 400 nm evaporated thin film on Mylar and from an infinitely thick iron section with different takeoff angles [32]. The incident beam size was restricted to 19 ~tm and 12 l~m in the horizontal and vertical directions, respectively. The XANES spectrum from the iron section with a takeoff angle of 40 ~ clearly shows spectral distortion resulting from the self-absorption which is described by the theoretical predictions (dotted lines). The results show that the effects of selfabsorption can be overcome with a detection-geometry having a small takeoff angle. The small-takeoff-angle technique is also effective with self-absorption effects in EXAFS spectra [33].
Z21 v
2=-
I--
03 Z I,.1.1
IZ
iii (.3 Z iii r.D 03 iii r'v" O Zl .,,.J Lt_
/i ,
I,
] !
I
7.10 X-RAY ENERGY/keV Fig. 3-12.
I
7.15
Micro XANES spectra of Fe obtained using the fluorescence detection method: (a), from a 400 nm evaporated thin film on Mylar and from an infinitely thick iron section with takeoff angle of, (b) 5 ~ and (c) 40 ~ Solid lines show the data obtained and the broken lines show the calculated XANES spectra [32].
190 3.4.3.
Chemical speciation with
XRF spectroscopy
Chemical speciation using X-ray fluorescence spectroscopy has had a long history since the 1920s. The XRF, caused by electronic transitions between the inner shells of an atom, shows chemical shifts which depend on the environment of an X-ray emitting atom. Band spectra caused by the electronic transition from the outer shell to the inner shell reflect the partial density of states of the valence band. The K-L(Ka) spectra of second row elements and KM(K[3) spectra of the third row elements are typical examples of valence band spectra. Figure 3-13 shows B K-V XRF spectra and boron K edge XANES spectra of B, BN and B203 [34]. As is widely known, the fluorescence cross section is small for light elements. Therefore these measurements were difficult without the brilliant X-rays from an undulator.
.! o ~
B
emission I
o
2?
h-B.
_
_
f'-J"
r
B203
!
x
.,..9":" o
150 Fig. 3-13.
ption
/
160
:
t :
o. !-
180 190 170 Photon energy / eV
P-200
210
X-ray fluorescence spectra and boron K-edge XANES spectra of B, BN and B203. To obtain the XRF spectra, monochromated first harmonics undulator radiation (212 eV) was employed.
191 For the observation of chemical effects in the XRF spectra from heavier elements, conventional XRF spectrometers have insufficient energy resolution. To overcome the limitations, a double crystal spectrometer which achieves adequate energy resolution for a wide angular range is preferable [35]. Although the spectrometer has been used successfully with the conventional X-ray sources, there has been no report of its use with the SR, owing to its low efficiency. Recently, another type of optical geometry has been reported which can realize high energy resolution utilizing SR. Figure 3-14 shows the experimental scheme [36]. A dispersed XRF spectrum is detected with a position-sensitive proportional counter(PSPC) and the energy resolution of the spectrometer can be adjusted via the beam-irradiated area and the sampledetector distance. In order to realize an energy resolution sufficient for chemical state analysis the beam size was restricted by narrow slits to 20 ~tm in the horizontal plane and the sampledetector distance was set to be 1010 mm. Figure 3-15 shows an XRF spectrum of Cu metal obtained with the (444) reflection of a mirror polished Si crystal. The FWHM of the Cu KL3(Kal) peak was 2.6 eV, which is almost identical to the natural width of the spectrum. Therefore the energy resolution, dE/E, of the spectrometer is supposed to be less than 3 x 10-5.
l-
1st slit
Di UI
I.C.
2nd slit
Sample
( Analyzer crystal
Fig. 3-14.
C
A wavelength-dispersive (WD) spectrometer with a position sensitive proportional counter (PSPC) [36]: IC is a He-filled ionization chamber.
192
| m
. . . . . . .
Cu K-L3 A
....
!
c
m
Cu N-L2
l
LL
Fig. 3-15.
Wavelength
Energy---~-
XRF spectra of Cu metal from a high-energy resolution WD spectrometer equipped with a Si(444) crystal [36].
3.4.4. Advantages of energy tunability As shown in this Chapter, the tunability of the energy of SR can be used for the selective excitation of an element of interest. In the XRF elemental analysis the selective excitation is applicable to trace element analysis in a matrix of heavier elements. When the incident X-ray energy is tuned to be just above the absorption edge energy of an element of interest, interferences of the XRF lines from matrix elements which are heavier than the analyte can be avoided. The sensitivity is also optimized for the element of interest. Moreover, when the incident energy is selected carefully, selective excitation of the element in a specific chemical state can be realized. Selective excitation also has importance in X-ray spectroscopies because it provides a well defined excitation condition. In conventional XRF spectroscopy, primary X-ray photons usually have sufficient energy to excite a core electron to the continuum level (or out of the atom). This means that the polarization is not conserved between the primary X-ray and the fluorescent X-ray and that there are chances of multiple ionization in an atom. When selective excitation is employed and the incident X-ray energy is tuned around the absorption edge of the element of interest, a core electron can be selectively excited to an unoccupied level in an atom, and the transition should satisfy the selection rule. Spectroscopic techniques which use
193 this selective excitation around the absorption edge
are sometimes called threshold
spectroscopies and can provide a variety of chemical information. One typical example of threshold spectroscopy is the elimination of multiple ionization satellites in XRF spectra. In X-ray fluorescence spectra there often appear satellite lines whose origin is not tabulated as diagram lines. Some of these satellites are attributed to multiple ionization of the X-ray-absorbing atom. Beside the well separated satellite there exists a linewidth satellite (or parasite) which is observed as a slight profile change or asymmetric smearing of the spectrum line. Kawai et al. have investigated the profile changes in chlorine KL2,3(K~l,2) XRF spectra, and the spectral changes have been explained in terms of the chemical state of the C1 atom [37]. The assignments of these lines were derived from theoretical calculations. However, the threshold technique provides spectral profiles without the multiple ionization satellite. The difference between with and without multiple ionization data will be useful for chemical state analysis. Figure 3-16 shows argon K-M(K[3) spectra obtained with several incident X-ray energies around the K absorption edge of Ar [38]. Fig 3-16(a) shows a typical spectrum obtained at high excitation energies. Satellite peaks are observed to the higher energy side of the main line. With incident X-rays of smaller excitation energy the satellite lines become smaller and finally there only appears the main line. Satellite peaks are therefore attributed to multiple ionization. By using the threshold techniques, gas molecules of similar orientation can be selectively excited and the anisotropy of X-ray fluorescence has been demonstrated [39]. The threshold technique is also important for studies of X-ray Raman scattering where resonant effects play an important role [40]. As threshold techniques require a narrow energy bandwidth, both for incident X-rays and fluorescent or scattered X-rays, most of the experimental results have been obtained with the high brightness X-rays from the undulator. In the present SR facilities the undulator source is limited to the soft X-ray region. However, with the next generation of SR facilities, threshold spectroscopy in the hard X-ray region will become a promising field of Xray spectroscopies.
194
~
a
.i--'
,:,,. "-"
23
x:i L. v
o3
b
o3
v
9
l
03 Z w
.
U.! "
; .~ 3175
Z
":-
9
Z
03
.&
9
3190
"~
. . . . z. . . .
3205
-~ .$,
-
I--
J
3175
-
-
,
3190
ENERGY/eV
X.__ .--
c
i_
j
r ":z5
L.
d
k.. o3
,.,._..
v
:=--
-1
F-
03 Z
9
9
I--
Z
UJ
I-
i
3175
B
0 3
"
Z
,3 ]90
32-05
3-i--7S
ENERGY/eV Fig. 3-16.
'
3205
ENERGY/eV .~.a
,-.
9
l--
F-
"
:" 9
A
".'- -
9
"
3190
3205
ENERGY/eV
Argon K-M(KB) XRF spectra obtained with incident photon energy at: (a), 3281.4 eV" (b), 3245.9 eV" (c), 3213.1 eV" and (d), 3199.2 eV[37].
3.5. A N A L Y T I C A L 3.5.1.
X-RAY MICROPROBES
Introduction
A scanning X-ray microprobe can provide most X-ray analyses with spatial resolution 9 Since the paper by Horowitz and Howell [3], various types of analytical microprobes and their applications have been reported. In this Section, the analytical feasibility of the SR X-ray microscope (microprobe) is shown 9 3.5.2. Trace element analysis with micro X R F
One of the strong advantages of the SR X-ray microprobe is its small heat load to a sample 9 Figure 3-17 shows a photograph and XRF images of a tree ring from an 80 year old Japanese
195 cedar. The trace element localized in the tree ring gives information about the environmental changes that have occurred over the last few decades. Owing to the low heat conductivity of the tree sections it is usually difficult to avoid severe heat damage. However, by utilizing the X-ray microprobe system shown in Fig 3-8(c) trace element localization in the sample was visualized without damage being observed.
Fig. 3-17.
(a) a photograph of a tree ring after irradiation by 10 keV monochromatic SR for XRF imaging and (b) Ca, (c)Cu XRF images of a tree ring. A region of 3mm • 3mm was analyzed with a data acquisition time of 10 s for each pixel. Spatially averaged
concentrations of Fe, Cu and Zn were less than lppm.
Figure 3-18 shows a SR XRF spectrum obtained from a chelate resin bead, which was prepared to contain 100 ppm of Ca, Mn and Zn. The experimental system shown in Fig. 3-8 was employed, with a spatial resolution of 2001am. For a data acquisition time of 100s the minimum detection limit (MDL) of Zn is less than 1 ppm.
196
4000 3000 0') I-, Z 2OO0 O 0
1000 C __/L 2 3 4
5
L A 6
7
8
9
10 11 12
X-RAY ENERGY/keV
Fig. 3-18.
A SR-XRF spectrum from a chelate resin bead, prepared so as to contain 100 ppm of Ca, Mn and Zn, excited with 10 keV monochromatic X-rays.
3.5.3.
Micro X A F S m e a s u r e m e n t and chemical state i m a g i n g
The advantage of the energy-tunable X-ray microprobe appears in
micro XAFS
measurements. By employing an experimental system as shown in Fig. 3-8 the Cu K-edge XAFS of an evaporated Cu film 15 nm thick was measured with a spatial resolution of 100 gm (Fig. 3-19)[21]. A Si(Li) detector was used for detecting Cu K-L fluorescence with a sample-detector distance of 15 mm. The obtained XAFS spectrum corresponds to that obtained from a Cu foil of appropriate thickness with transmission measurement. Consideration of the beam size shows that the absolute amount of measured Cu was less than 1 ng with a data acquisition time of approximately 2h.
_J UJ >m
klJ O tu
8.8 ~9
LL
Fig. 3-19.
9.0
9.2
9.4
9.6
9.8
X-RAY ENERGY/keV
Copper K-edge XAFS spectrum obtained from a Cu-deposited thin film of 15 nm thickness.
197 As described previously,
XANES spectra can be used to provide "finger prints" of
materials. However, when the sample is in a mixture of several chemical states it is usually difficult to obtain the chemical state information because the measured XAFS spectra are affected by the overlap. Sakurai et al. have employed a novel technique to separate the chemical state in a binary system [41]. Figure 3-20 shows evaporated test patterns with Cr. The character "PF" is patterned with Cr203 and the rest of the area is patterned with Cr metal. The surface density of Cr is uniform within the sample. It is usually difficult to distinguish differences in chemical states using the XRF imaging technique. However, when the excitation energy is tuned to that in the absorption-edge region the difference in an excitation cross section can be emphasized. To separate the XANES spectra of Cr and Cr203, two excitation energies were chosen. One is the excitation energy that gives equal XRF signals for the same Cr surface density of the different compounds. The other is an energy that gives a large contrast between the two compounds. After the XRF imaging with two energies the XRF images are numerically processed to obtain separate images of each component. Figure 3-20(b) shows the extracted Cr image that clearly shows the characters. In this experiment the images were obtained using the image reconstruction technique, the principle is applicable to all kinds of XRF imaging techniques.
Fig. 3-20.
(a) Optical micrograph of the sample. The region measured is shown in the circle. The letters "PF" were Cr, and Cr203 was deposited around them (b) Cr image processed by the image reconstruction technique; the Cr203 image obtained was a reversal of the Cr image [41].
198 In the soft X-ray region, micro XANES measurements have been applied to polymer blends of polypropylene and a 50:50
weight percent random styrene-acrylonitrile copolymer [42].
Figure 3-21 shows carbon K-shell XANES spectra of polymers, obtained using transmission measurements. The incident X-rays were focused using a zone plate and a spatial resolution of 55 nm was realized. As the focus of the zone plate depends on the incident X-ray energy, focusing adjustments were carried out at each incident X-ray energy while the XANES spectra were measured. By choosing the incident X-ray energy for the resonance peaks of each polymer, X-ray images with chemical contrasts were obtained (Fig. 3-22). As a peak at 285.5 eV corresponds to an antibonding ~-orbital resonance of styrene an X-ray image from transmitted X-rays gives a high contrast to the styrene-acrylonitrile copolymer in the polymer blends. Micro-XANES measurements in the soft X-ray region are receiving great attention, especially in the field of biology. A trial to visualize the DNA distribution in a chromosome has also been reported, utilizing a technique similar to that of Sakurai et al. [41 ]. ,
i
,
I
. . . .
i
. . . .
. . . .
i
. . . .
A
,L
B
4 ~. ....
-.. ~ . . . _ L
c
e3 < o
2
u
2
i
r
In o u
1
0
. . . .
280
i
. . . .
285
i
. . . .
i
290
photon
295
energy
. . . .
i 300
. . . .
0 305
(eV)
280
,
,
,
,
i 285
. . . .
,
. . . .
290 pholon
i 295
energy
. . . .
,
,
i
,
,
30fl
(eV)
4
c
~2
._ u
| i e
i o
280
285
290
photon
Fig. 3-21.
295
energy
300
305
(eV)
Carbon K-shell XANES spectra of: (A), polyacrylonitrile; (B), polystyrene" and (C), polypropylene (dashed line) and a 50:50 percent by weight random copolymer of polystyrene and acrylonitrile (solid line) [42]
199
Fig. 3-22.
Images of a 0.5 ~tm-thick section of a blend consisting of polypropylene and a 50:50 percent by weight random styrene-acrylonitrile copolymer at the following photon energies: (A), 285.5 eV; (B), 286.2 eV; (C), 286.8 eV; and (D), 287.9 eV. The contrast arises from differences in the near edge absorption cross section of the different domains as shown in Fig. 3-21(C) [42].
3.5.4. Trace element characterization with micro X R F and micro X A F S
A combination of micro XRF and micro XAFS measurements becomes a powerful tool for the characterization of trace elements in a sample. Large synthetic diamond crystals are grown under high pressure and temperature with some metallic solvents. For the industrial use of the diamonds the characterization of impurities originating from the metallic solvent receives great attention. However, very few elements concentration.
have been characterized because of their
low
Figure 3-23 shows X-ray images of a diamond crystal grown with Ni-Fe
solvents, measured using the experimental system shown
in Fig. 3-8(c) with a spatial
resolution of 200 ~tm [43]. To maintain the spatial resolution the diamond crystal was polished into a plate 277 ~m thick, parallel to the { 110} plane. The sample was fixed onto a plastic sheet to reduce inelastic scattering which overlaps with the XRF signal. The Ni XRF image clearly shows that Ni exists selectively in the { 111 } growth sector. Figure 3-24 shows the SR XRF spectra obtained from { 111 } and { 100} sectors in the sample. Iron was not detected in either of these, twithin the sensitivity available. The X-ray images and XRF spectra confirmed selective dissolution of Ni into the { 111 } growth sector.
200
Fig. 3-23.
X-ray images of a sliced single crystal of synthetic diamond under high pressure and high temperature. (Upper left) Ni image, (Upper right) Fe image, and (Lower left) transmitted X-ray image.
1.2
1.6
Scattered x-rays
,,--., 1.0
1.4
0.8
0
1.2
Ni K~
,, 0.6
1.0
0.4
m
0.8
03 Z 0.2 LLi
{111}
-0.2
{100}
IZ
0.6
o.o
0.4
-0.4 5
0.2 0.0
6
7
8
9
10
X-RAY ENERGY/keV Fig. 3-24.
SR-XRF spectra of the synthetic diamond crystal taken at two different positions on the sample.
201 To evaluate the Ni concentration in the { 111} growth sector an absorption correction method was employed which measures the transmittance at each small area of interest and corrects for the self absorption effects inside the sample [44]. The resultant concentration value ik~r Ni was supposed to be 30 ppm for the { 111} growth sector and less than 0.3 ppm for the { 100} sector. Micro XAFS measurements have also been applied to the trace Ni in the diamond [45]. Figure 3-25 shows the Ni K-edge XANES measured at a { 111 } growth sector in a diamond. Its profile is quite different from that of metallic Ni. Therefore, it is confirmed that the Ni atoms inside the diamond crystal are not part of the small inclusions but are dissolved in the diamond lattice. From empirical knowledge about the pre-edge peak in the XANES profile it is suggested that the Ni is in a tetrahedral site. 1.0 0.8 0.6 0.4
z
0.2
l
0.0
8300
1
8320
I
8340
|
8360
I
8380
8400
X-RAY ENERGY/eV Fig. 3-25.
Nickel K-edge XANES of Ni dissolved into { 111 } growth sector of the synthetic diamond crystal.
3.5.5.
Other analytical m e t h o d s with the m i c r o b e a m
With the use of an X-ray microprobe various kinds of X-ray analyses can be perIormed with spatial resolution. In the field of micro X-ray diffraction (XRD) there have been several reports [46--49] following the initial preliminary report [49]. The local structure of the zig-zag defect boundaries in surface stabilized ferroelectric liquid crystal cells has been investigated using an X-ray microprobe equipped with Kirkpatrick-Baez mirrors. Rocking curves measured as a function of the sample position have determined the local layer structure [48]. Another use of the X-ray microbeam is in high angular resolution measurements of signals from a local position on the sample. One successful application is in grazing-exit detection for
202 surface sensitive measurements. As has been theoretically and experimentally demonstrated by several groups using conventional X-ray sources [50], the reciprocity of incident and exiting X-rays suggests the existence of a critical takeoff angle which is similar to the critical angle of total reflection. By detecting XRF with takeoff angles around the critical angle, layers near to the surface down to several tens of angstroms, can be selectively investigated. After the surface-sensitive XAFS application [51], a combination of the X-ray microprobe and the grazing-exit detection has been reported [52]. For chemical-state analysis one of the promising spectrochemical microscopes is the photoelectron microscope. Experiments can be carried out using a zone plate [53], ellipsoidal min-or [54], multilayer coated Schwarzschild optics [55] scanning photoelectron microscopes,
many
or Wolter mirror [56]. As well as the
electron-imaging microscopes have been
reported[56]. Incident SR X-rays are used to illuminate the sample in the field of view. The spatial resolution of the microscopes is determined by the electron-image-forming optics and, particularly when one considers the difficulties in realizing a focused microbeam in the hard Xray region, this method is of promise in realizing a spectroscopic microscope.
3.6.
FUTURE
EXPECTATIONS
WITH
THE
THIRD
GENERATION
SR
SOURCE
In the preceding Sections, several types of microprobes and their applications Ior chemical state analysis are described. Although the potential of an energy tunable X-ray microprobe has been recognized with the second generation SR sources the practical applications in the hard Xray region are still limited owing to the difficulties in realizing an intense X-ray microbeam. As is successfully demonstrated in the soft-X-ray region the characteristics of the undulator radiation, such as small emittance and high brilliance, are suited to an X-ray microprobe, and the X-ray microprobe with the hard-X-ray undulator has received great attention. The recent innovation of an in-vacuum undulator has made it possible to produce hard-X-ray undulator radiation. The in-vacuum undulator was installed in the 6.5 GeV TRISTAN Accumulation Ring (AR) at the Photon Factory. By changing the magnet gap from 1 to 5 cm, the photon energy of the first harmonics can be tuned from 5 to 25 keV. Brilliant 14.4 keV X-rays were used successfully for M0ssbauer experiments [58]. It is clear that the high brilliance
of undulator radiation is suited for a variety of
spectroscopic techniques. Fig. 3-26 shows an example of an experimental arrangement for high-energy-resolution X-ray fluorescence spectroscopy [59]. To realize chemical state analysis using the threshold technique, an energy resolution (AE/E) of better than 10. 4 is
203 required for both the incident X-ray monochromator and XRF spectrometer. Owing to the poor efficiency of the XRF spectrometer, the threshold spectroscopy is difficult to achieve with SR from the bending magnets. However, threshold spectroscopy in the hard X-ray region is one of the promising applications to use the third generation SR sources. The high brilliance source helps not only high-energy-resolution spectroscopies but also measurements with high angular resolutions and with high spatial resolutions. The combination of high resolution spectroscopies has promise in characterizing heterogeneous systems. An X-ray microprobe equipped with the grazing exit XRF detection system can provide information on three dimensional trace-element-distilbution. In addition to the expansion in spectroscopic applications the low emittance source will widen the choice of optical elements. A smaller source directly implies a reduction in the focused beam size. Moreover, the small divergence makes the practical use of focusing optics of small acceptance. The limitation of the total-reflection mirror owing to the small sagittal acceptance becomes less important and a focusing mirror which covers more than 20 keV can be used. The small divergence is also suited to capillary tubes [60, 61] whose acceptance is extremely small. By using the third generation SR source, an adequate photon flux may be obtained with the capillary tubes.
SR_
Excitatior
XRF/
U
hv
Detector
Sample Fig. 3-26.
Precise c.hemical state analysis[59]
204 REFERENCES
1.
V.E. Cosslett and W.C. Nixon (Editors), X-ray Microscopy, Cambridge University
2.
A. Engstrom, V. E. Cosslett and H. H. Pattee (Editors), X-Ray Microscopy and X-Ray
Press, Cambridge, 1960.
,
4. 5. 6. 7. 8. 9.
Micro-analysis, Elsevier, Amsterdam, 1960. P. Horowitz and J. A. Howell, Science (Washington, DC), 178 (1972) 608. P. Horowitz, Ann. NY Acad. Sci., 306 (1978) 203. J. A. Howell and P. Horowitz, Nucl. Instrum. Methods Phys. Res., 125 (1975) 225. C. J. Sparks Jr., in H. Winick and S. Doniach (Editors), Synchrotron Radiation Research, Plenum, New York, 1980, Ch. 14. G. Schmahl and D. Rudolph (Editors), X-Ray Microscopy, Springer, Berlin, 1984. P.C. Chen and G. J. Jan (Editors), X-Ray Microscopy H, Springer, Berlin, 1987. A.G. Michette, G. R. Morrison, C. J. Buckley (Editors), X-Ray Microscopy III, Springer, Berlin, 1992.
10.
K. Saitoh, R. Inagawa, K. Kohra, C. Hayashi, A. Iida and N. Kato, Jpn. J. Appl.
N.
Phys., 27 (1988) L2131.; K. Saitoh, K. Inagawa, K. Kohra, C. Hayashi, A. Iida and Kato, Rev. Sci. Instrum., 60 (1989) 1519.
11.
B. Lai, W. B. Yun, D. Legnini, Y. Xiao, J. Chrzas, P. J. Viccaro, V. White, S. Bajikar, D. Denton, F. Cerrina, E. Di Fabrizio, M. Gentili, L. Grella and M. Baciocchi, Appl.
Phys. Lett., 61 (1992) 1877. 12.
P. Kirkpatrick and A. V. Baez, J. Opt. Soc. Am., 9 (1948) 766.
13.
V.H. Wolter, Ann. Phys., 6 (1952) 286.
14.
V.H. Wolter, Ann. Phys., 6 (1952) 94.
15.
Y. Gohshi, S. Aoki, A. Iida, S. Hayakawa, H. Yamaji and K. Sakurai, Jpn. J. Appl.
Phys., 26 (1987) 1260. 16.
S. Hayakawa, A. Iida, S. Aoki and Y. Gohshi, Rev. Sci. Instrum., 60 (1989) 2452.
17.
Y. Suzuki, F. Uchida and Y. Hirai, Jpn. J. Appl. Phys., 28 (1989) L1660.
18.
Y. Suzuki and F. Uchida, Jpn. J. Appl. Phys., 30 (1991) 1127.
19.
A. Iida and T. Noma, Nucl. Instrum. Methods Phys. Res., B82 (1993) 128.
20.
S. Hayakawa, Y. Gohshi, A. Iida, S. Aoki and M. Ishikawa, Nucl. Instrum. Methods
Phys. Res., B49 (1990) 555. 21.
S. Hayakawa and Y. Gohshi, in A. G. Michette, G. R. Morrison, C. J. Buckley (Editors), X-Ray Microscopy III, Springer, Berlin, 1992, p.364.
22.
K.W. Jones, P. A. Takacs, J. B. Hastings, J. M. Casstevens and C. D. Pionke, Proc. SPIE- Int. Soc. Opt. Eng., 749 (1987) 37.
205 23.
A. C. Thompson, Y. Wu, J. H. Underwood and T. W. Barbee, Nucl. Instrum.
Methods Phys. Res., A255 (1987) 603. 24.
J. H. Underwood, A. C. Thompson, Y. Wu and R. D. Giauque, Nucl. Instrum.
Methods Phys. Res., A266 (1988) 296. 25.
F.v. Langevelde, G. H. J. Tros, D. K. Bowen and R. D. Vis, Nucl. Instrum. Methods'
Phys. Res., B49 (1990) 544. 26.
V. Baryshev, G. Kulipanov and A. Skrinsky, in G. Brown and D. E. Moncton
27.
P. Dhez, A. Erko, E. Khzmalian, B. Vidal and V. Zinenko, Appl. Opt., 31 (1992)
(Editors), Handbook on Synchrotron Radiation Vol.3, Elsevier, 1991, Ch. 16. 6662. 28.
F. Legrand, A. Erko, P.Dhez, P. Chevallier and C. Engrand, in V. V. Aristov, A. I. Erko (Editors), X-Ray Microscopy IV, Institute of Microelectronics Technology Chernogolovka, Russia, 1994, p. 136.
29.
C. J. Sparks, G. E. Ice, J. Wong and B. W. Batterman, Nucl. Instrum. Methods" Phys.
Res., 194 (1982) 73. 30.
V. V. Aristov, Yu. A. Basov, S. V. Red'kin, A. A. Snigrev and V. A. Yunkin, Nucl. I
31.
K. Sakurai, A. Iida and Y. Gohshi, Anal. Sci., 4 (1988) 37.
32.
S. Hayakawa, Y. Gohshi, A. iida, S. Aoki and K. Sato, Rev. Sci. Instrum, 62 (1991)
nstrum. Methods Phys. Res., A261 (1987) 72.
2545. 33.
D. M. Pease, D. L. Brewe, Z. Tan, J. I. Budnick and C. C. Law, Phys. Lett., A 138 (1989) 230.
34.
Yasuji Muramatsu, Ph.D. thesis, Tohoku University (1992).
35.
Y. Gohshi, Y. Hukao and K. Hori, Spectrochim. Acta., 27B (1972) 135.
36.
K. Ohashi, M. Takahashi, Y. Gohshi, A. Iida and S. Kishimoto, Adv. X-ray Anal. 35 (1992) 1027.
37.
J. Kawai, C. Satoko, K. Fujisawa and Y. Gohshi, Phys. Rev. Lett., 57 (1986) 988.
38.
R. D. Deslattes, R. E. LaVilla, P. L. Cowan and A. Henins, Phys. Rev., A27 (1983) 923.
39.
S. H. Southworth, D. W. Lindle, R. Mayer, P. L. Cowan, Phys. Rev. Lett., 67 ( 1991) 1098.
0,
41.
Y. Udagawa and K. Tohji, Chem. Phys. Lett., 148 (1988) 101. K. Sakurai, A. Iida, M. Takahashi and Y. Gohshi, Jpn. J. Appl. Phys., 27 (1988) L1768.
2.
H. Ade, X. Zhang, S. Cameron, C. Costello, J. Kirz and S. Williams, Science
(Washington, DC ), 258 (1992) 972.
206 3,
M. Wakatsuki, S. Hayakawa, S. Aoki, Y. Gohshi and A. Iida, New Diamond Sci.
Technol., Proc. Int. Conf., (1991) 143. 4,
45.
S. Hayakawa, A. Iida and Y. Gohshi, Anal. Sci., Suppl. 7(1991)509. S. Hayakawa, F. Nakamura, Y. Gohshi, M. Wakatsuki and H. Kagi, Trans. Mater.
Res. Soc. Jpn., 14B (1994) 1559. 46.
T. Hirano, F. Higashi and K. Usami Rev. Sci. Instrum., 63 (1992) 5602.
47.
F. Nakamura, S. Hayakawa, M. Wakatsuki, H. Kagi and Y. Gohshi, Photon Factory
Activity Report #10 (1992) 54. 8,
49.
A. Iida, T. Noma and K. Hirano, Ferroelectrics, 149 (1993) 117. G.E. Ice, Nucl. Instrum. Methods Phys. Res., B24/25 (1987) 397.
50.
R. S. Becker, J. A. Golovchenko and J. R. Patel, Phys. Rev. Lett., 50 (1983) 153.
51.
Y. Suzuki, Phys. Rev., B39 (1989) 3393.
52.
T. Noma and A. Iida, Rev. Sci. Instrum., 65 (1004) 837.
53.
H. Ade, J. Kirz, S. L. Hulbert, E. D. Johnson, E. Anderson and D. Kern, Appl. Phys.
Lett., 56 (1990) 1841. 54.
.J. Voss, H. Dadras, C. Kunz, A. Moewes, G. Roy, H. Sievers, I. Storjohann and H. Wongel, J. X-ray Sci. Technol ., 3 (1992) 85.
55.
G. Margaritondo, F. Cerrina, Nucl. Instrum. Methods Phys. Res., A291 (1990) 26.
56.
K. Ninomiya, M. Hasegawa, S. Aoki and K. Suzuki, Jpn. J. Appl. Phys., 30
57.
B. P. Tonner and G. R. Harp, J. Vac. Technol., A7 (1989) 1.
58.
S. Yamamoto, X. Zhang, H. Kitamura, T. Shioya, T. Mochizuki, Y. Yoda, S. Kikuta
( 1991) 2889.
and H. Takei, J. Appl. Phys., 74 (1993) 500. 59.
Y, Gohshi, Nucl. Instrum. Methods Phys. Res., A303 (1991) 544.
60.
H. Nakazawa, J. Appl. Cryst., 16 (1983) 239.
61.
D. H. Bilderback, S. A. Hoffman and D. J. Thiel, Science (Washington, DC), 263 (1994) 201.
Applications of SynchrotronRadiation to Materials Analysis H. Saisho and Y. Gohshi (Editors) 1996 Elsevier Science B.V.
207
CHAPTER 4
X-RAY A B S O R P T I O N FINE S T R U C T U R E Hiroyuki OYANAGI Electrotechnical Laboratory 1-1-4 U m e z o n o , T s u k u b a , Ibaraki 305, Japan
4.1. INTRODUCTION 4.1.1. Interactions of photons with atoms and molecules By varying the energy and polarization of incident photons, one can study the microscopic structure and electronic states through the various interactions of the photons with a variety of materials ranging from clusters to macromolecules as schematically illustrated in Fig. 4-1. Reflected and transmitted photons conventionally provide information on the electronic states of a system. Elastically and inelastically scattered photons are used to study the microscopic structure. One can obtain information on the electronic states of occupied states by analyzing the energy of photoelectrons. On the other hand, X-ray absorption spectroscopy (XAS) provides a means of studying the unoccupied states and the local structure around an excited species of atom [1]. The advantage of XAS is its selectivity for atomic species and sensitivity to the atomic arrangements [2,3]. The relation between the fine structures and crystal structures has been recognized from an early stage. Historical developments which established the fundamental aspects of the fine structures based on a short-range order theory are reviewed in detail in the literature [4]. Even if the system has many elements, a particular species of atom can easily be selected by tuning the photon energy to one of the inner shell absorption edge energies. Moreover, since the interaction is strongly polarized, the information on the geometrical arrangements of atoms, or the radial distribution in a particular direction, can be obtained. These characteristics make synchrotron radiation an ideal light source, in that it provides an intense polarized light over a wide range in energy. XAS has advanced rapidly since the application of synchrotron radiation in the early 1970s [5]. The advances in experimental techniques have been inspired by a simple interpretation of fine structures, based on a single scattering theory [6] and a Fourier transform analysis [7]. Reviews on modem XAS
208 Incident
photons
Surface r Interface [
Scattered photons
Fluorescence
/
/
//
,/Photoelectron
Aucjerelectron
Bulk
Fig. 4-1. Schematic representations of the various interactions of photons with atoms and molecules. are available [8,9] and the theories and analytical methods are described in detail. In this Chapter, the recent experimental advances in XAS as a structural probe in a hard X-ray region (> 4 keV) are reviewed. The capabilities of high-brilliance photon sources, i.e., insertion devices, for the studies of dilute systems are demonstrated, and the future prospects of a tunable X-ray undulator for the third-generation storage rings [ 10] are discussed.
4.1.2. X-ray absorption fine structure (XAFS) X-ray absorption fine structure (XAFS) is a general terminology for extended X-ray absorption fine structure (EXAFS) and X-ray absorption near edge structure (XANES) techniques. In general, EXAFS refers to the sinusoidal oscillations observed over a wide energy range extending ~1000 eV above the edge, while XANES refers to fine structures around an absorption edge extending typically -50 eV. In Fig. 4-2, the Ge K-edge absorption spectra are shown as a function of photon energy for glassy and crystalline GeO2 [ 11 ]. In the trigonal crystal structure, each Ge atom is coordinated by four oxygen atoms forming a tetrahedral unit. These tetrahedra are linked by two-fold coordinated oxygen atoms which occupy the corner positions of each tetrahedron [ 12]. Clearly, the absence of long-range order has little effect on the XANES and EXAFS regions; the spectral features in a glass are broadened but the essential features are preserved. This fact naively suggests that the glass has a short-range order as the fine structures arise from interference between the outgoing and scattered photoelectrons. The fine structure in X-ray absorption spectra and its relationship to
209 I
'
I
I
'
I
'
I
'
I
'
I
"
'
I
GeO2 80K
Ge K- edge
z D
~...,..,_..,,~, f'\,_. . . . . . .
I-IIl
trigona I glass
A .m
I !
0 0,~
I C
I
10.8
,
I
11.0
,
I
11.2
,
I
1t.4
,
I
,
11.6
I
11.8
,
I
12.0
,
I
12.2
ENERGY (keY) Fig. 4-2. Ge K-edge absorption spectra for glassy and trigonal GeO2" taken from ref. 11. Above the K-shell excitation energy (11.11 keV), near-edge and extended fine structures are observed. the crystal structure have been recognized from an early stage. Until recently, however, the quantitative understanding of XAS has been hindered because of poor quality. The experimental techniques of XAS have been improved dramatically by the use of synchrotron radiation. Synchrotron radiation has outstanding advantages as a light source for XAS. These are, (1) a wide spectral range covering the VUV and soft X-ray regions, where the light elements such as C and O have absorption edges (250 eV-4 keV), to a hard X-ray region (4-30 keV) where elements heavier than Ca (Z = 20) have absorption edges: (2) an intense quasiparallel beam which allows us to measure XAFS with a high energy resolution [13] or energy dispersive geometry [14]: and, (3) a variety of polarization characteristics with high purity and controllability. In general, a linear polarization from a bending magnet is used for polarization dependent experiments, while one can obtain linear [ 15], circular [ 16], and elliptical [ 17] polarization using special insertion devices. The improved quality of XAS obtained with synchrotron radiation made possible the quantitative analysis of experimental data. Partly driven by a motivation to utilize the technique as a unique local structural probe, the theoretical understanding has been accelerated [ 18-20]. In the 1970s, various new experimental techniques were evolved, such as an electron detection technique [21 ] as a means of surface-sensitive measurement, a fluorescence detection technique
210 [22] to enhance sensitivity for dilute systems, and an energy-dispersive technique [ 14] for timeresolved experiments. These new techniques have spread the capabilities of XAFS to cover a wide area from physics to biology. Dedicated synchrotron light sources, often referred to as the "second-generation" storage ring, are characterized by a low emittance and high stability. Such facilities made possible a high-energy-resolution near-edge spectroscopy called XANES [23] or NEXAFS [24] (near-edge X-ray absorption fine structure) which can probe elaborate changes in coordination geometry. It should be noted that the capability of XAFS is strongly dependent on the characteristics of the light source. In this sense, the XAFS technique is indeed still developing with the evolution of the light source. 4.1.3. Uniqueness as a structural probe
In contrast to diffraction techniques, which give the atomic coordinates as a macroscopic average, XAFS provides the information on a local structure, i.e., the radial distribution and electronic states around a particular species of atom. The uniqueness of XAFS is attributed to its physical origin, the interference of outgoing and scattered photoelectron waves from the central atom, which modulates the matrix element of a dipole transition. Such an interference does not require a long-range order and reflects a "partial" radial distribution around an excited atom, extending to several A because of the rather short mean free path of ejected photoelectrons. Schaich [20] has shown that the short-range [1] and long-range order [25] theories are equivalent if the inelastic energy loss of photoelectrons is taken into account. A great advantage is the tunability for atomic species; the energies of various inner shells are distributed over a wide range in energy and one can tune to a particular species of atom and inner shell by choosing the energy of incident photons. The superior capabilities of XAFS as a local structural probe are fully exhibited in studies of dilute, multi-element systems, in particular, those without long-range order. XAFS is complementary to crystallography or scattering techniques, which provide the average or macroscopic structure with a long-range order. On decreasing the quantity of the atom species of interest, or increasing the number of constituent atoms, the uniqueness of XAFS as a local structure probe becomes particularly evident. For a structurally disordered system, the correlation between atoms is described by a radial distribution function for elements. For a disordered system consisting of more than two elements, it is necessary to separate partial radial distribution functions from either an isomer effect in neutron diffraction or an anomalous scattering effect in X-ray diffraction. This problem is difficult for disordered systems consisting of more than two elements and it is practically impossible to handle three-component systems. A general problem of crystallography is the lack of accuracy in the local structure. Biological systems usually contain only a few atoms in a macromolecule consisting of several tens of thousands of atoms, and the analysis of local structure is not reliable even if single crystals are prepared [26]. For biological systems, the local structure is strongly related with biophysical functions and it is important to study the coordination in enzymes and heme proteins in vivo [27].
211 4.1.4. Evolution of XAFS
The recent advances in the experimental techniques of XAFS are demonstrated in Fig. 4-3 where the Ge K-edge absorption spectra for trigonal GeO2 powder taken on various spectrometers and synchrotron radiation facilities are compared [11 ]. The top spectrum, (a), was obtained using an in-house EXAFS apparatus using Bremsstrahlung, by Lytle et al. [28] while the middle spectrum, (b), indicates the data obtained by using the first-generation storage ring. Although it appears that the spectral quality is much the same between (a) and (b), the statistics and data collection time are improved in (b) by more than two orders of magnitude [29]. Since a typical magnitude of modulation is of the order of 10-2 and the statistical error must be less than 10-3 , one needs to collect at least 106 photons for the incident and transmitted beam intensities. Since the photon flux is usually reduced by several powers of ten after the absorption, the XAFS experiments require a high photon flux. Synchrotron radiation has not only reduced the data collection time by several orders but has also improved the accuracy as a structural probe. In Fig. 4-3, new near-edge features are resolved in (c), taken on
GeOz
(13)
in-laboratory system Lytle (1965) .m t.-
(b) <:1:
DCI storage ring of LURE (Orsay, FRANCE) Lapeyre et al. (1983)
~=~
(c)
Photon Factory (present work)
l
11.0
I
I
11.5 12.0 Energy (keV)
Fig. 4-3. Comparison of Ge K-edge absorption spectra for trigonal GeO2 taken on various spectrometers 9from ref. 11.
212 a spectrometer at the second generation storage ring. A high-energy resolution is achieved by a low emittance and a narrow width of monochromator-crystal rocking-curve. As a result, the near-edge features have been revealed and the theoretical understanding of XANES has been advanced. The evolution of the XAFS technique is evidenced by the surface-sensitivity in a hard X-ray region, which improved by several orders of magnitude in the late 1980s, as will be discussed. It is interesting to note that the recent progress in XAFS is certainly due to the correlated developments in experimental techniques and theories which strongly inspired and accelerated each other's progress. 4.2. P R I N C I P L E S
4.2.1. Extended X-ray absorption fine structure (EXAFS) EXAFS is an interference phenomenon of photoelectrons, which occurs between the outgoing waves and the scattered waves and modifies the matrix element of core-excitation or X-ray absorption. Since the dominant interference involves the path lengths between the absorbing (central) atom and a scattering atom 2r, the 2kr oscillations are observed in k-space, in contrast to kr oscillations in a well-known formula for electron scattering. The propagation of photoelectrons is described in terms of the exact spherical waves [30] or curved waves [31 ]. Since the interference of photoelectrons is detected on an excited atom, the information is intrinsically local. Within a single scattering formalism [6], the interference among the three components, i.e., the outgoing wave, the single-scattering path, and the double-scattering path of the lowest order, is dominant. The photoelectrons emitted from an excited atom as spherical waves rapidly damp because of inelastic effects. This fact limits the probed spacial range but it also ensures that contributions of multiple-scattering beyond double-scattering are neglected. The fact that multiple-scattering effects can be ignored for the nearest-neighbor scattering allows us to analyze the data by a simple Fourier transform [7]. In Fig. 4-4, a scheme of the photoemission process is shown. In X-ray absorption, the bound electrons are ejected when the incident X-ray with an energy hv exceeds the binding energy E0. Accordingly, the absorption coefficient increases sharply at the threshold energy E0, above which fine structures are observed over 1 keV or more. Figure 4-2 shows a steep rise of absorption coefficient at ~11.11 keV, the onset of the Ge K-edge or the s-state absorption. The fluorescence X-rays [22] and Auger electrons [21], and, in some cases, the luminescence yields [32] are proportional to the absorption coefficient, and these quantifies provide alternative means to monitor the absorption coefficient. Photoelectrons propagate as a spherical wave having a kinetic energy Ekin, which is given as follows.
Ekin -- h v - EO
(4-1)
213
Photoemission
Process
Ekin hv - F'o =
T
Auger electron
Valence bond
~ ~
Core Levels
i
=
2pz/ 2 2p~/z
2L_,,- Fluorescent ~--~---- ls
v
X-roy Absorption
X-roy Emission
Fig. 4-4. Schematic representation for the photoemission process. Photoelectrons are emitted when the incident photon energy exceeds the binding energy. Radiative and nonradiative decays of excited states are associated with the characteristic X-rays or Auger electrons. where h v is the incident X-ray energy and E0 is the binding energy. The photoelectron wave vector k is then defined as
k = 2n h-1 [2m ( h v - E 0 ) ] 1/2
(4-2)
The excited states return to the ground states either radiatively or nonradiatively. In the former case, characteristic X-rays are emitted as a fluorescence with an energy difference between the excited shell and outer shell. In the latter case, Auger electrons with the same amount of kinetic energy are ejected. In Fig. 4-5, a scheme for the interference of photoelectrons with the wave vector k is shown, where 0 denotes the angle between k and radial vector r. Dashed arrows indicate the outgoing photoelectron and solid lines indicate the scattered photoelectrons. The EXAFS modulations in an absorption coefficient result from the interference between the direct wave going from an excited atom (0) and waves scattered by surrounding atoms (1, 2). Among various pathways for photoelectrons, the interferences between the direct wave and singly scattered paths (0-1, 0-2) and the lowest order doubly scattered paths (0-1-0, 0-2-0) are important. The probability of emitting a photoelectron in the direction k is given by
214
EXAFS
XANES
o
o-z-~
@ o_,_o',x,, 0 / / o-2-6 \~-/,r
o0-
~
,.
o-2-o ' , \ / /
o-I-z-o
Central Atom ,oz Scatterer Atom
\, ,
o 9
I
o-l-2 \ \ \
" -
r~
-@2
Fig. 4-5. Principle of EXAFS. Photoelectrons ejected from an excited atom (0) are scattered through the potentials of near-neighbor atoms (1, 2). Outgoing spherical waves interfere with scattered waves causing a modulated transition probability. 0 denotes the angle between k and radial vector r.
P(k) = D[e.k + f(O)/r exp(ikr(1-cos 0)) e.r] 2
(4-3)
where e is the electrical field vector, D is a constant and f(/9) is the scattering amplitude. Implicit assumptions in a single-scattering formalism are the following; a plane wave approximation is assumed, a single-scattering pathway is considered as the dominant interference; a muffin-tin type of potential is assumed for excited and scatterer atoms; and a sudden approximation for the core hole potential. The first term in Eqn. (4-3) expresses the outgoing wave and the second term is the scattered wave, where r(1-cos0) denotes the interference path length. The total absorption coefficient/1 is obtained by spherical integration of Eqn. (4-3) and if the normalized modulation of the absorption coefficient is defined as A/1//1, EXAFS Z as a function of k is obtained from the cross-term of the fight hand side in Eqn. (4-3), since other terms are smooth functions of photon energy or vanish, canceling with a part of the cross-term. The interference term is given by
~dk/4n e.k f(O)/r exp(ikr(1-cosO)) e.r
(4-4)
Using a spherical wave expansion and integration angle over 0, Eqn. (4-4) is given by
215
z(k) = -3 [(e.k) 2 / kr2]f(k,n) exp(2ikr) = -3 [(ok) 2 [ kr 2] If(k,n)l exp(2ikr+~k))
(4-5)
The forward scattering term in Eqn. (4-4) cancels with the second term of the square in Eqn. (4-3). For single-scattering paths (0-1, 0-2), the central atom phase shift is canceled and only the back-scattering phase shift ~k) is left in the equation. If we take only the double scattering paths with the shortest path lengths (0-1-0, 0-2-0) into account, and generalizing the formula for Ni scatterer atoms at ri, with a mean-square relative displacement (MSRD) oi, then z(k) is given by
z(k) = -3E [Nj (e.ki) 2 / krj 2] I~(k,n)l sin(2ikr+~k)) x exp(-2oj2k 2) exp(-2rj/~,j) = - 3 E [Nj cos20j/krj 21 I~(k,n)l sin(2ikr+gt(k)) • exp(-2oj2k 2) exp(-2rj/~,j)
(4-6)
where Aj is a mean free path of photoelectron and ~k) is a total phase shift function which is a sum of the central atom phase shift 2~0(k) and scatterer atom phase shift 0(k).
~ k ) = 2~0(k) + ~(k)
(4-7)
Since the total phase shift is approximately a linear function of k, the magnitude of the complex Fourier transform gives a peak maximum shifted to smaller r. Empirical data analysis procedures are based on the fact that this phase shift is transferable, i.e., once the total phase shift is established for a given pair of absorbing atom and scatterer atom, it is independent of the nature of the chemical bond, allowing one to extract structural parameters from one compound and apply them to other systems. On the other hand, Teo and Lee published tabulated values of theoretical amplitude and phase shift functions using a plane wave approximation for outgoing photoelectrons[33]. Such theoretical calculations are quite useful, in particular when an appropriate model compound with a known structure is not available. Later, McKale et al. have calculated the scattering amplitude and phase shift on the basis of a
216 curved wave approximation [34], which improved tile calculated phase shifts in the low kregion for high-Z elements. Figure 4-6 shows the back-scattering amplitude and phase shifts calculated for In (Z=49), Ge (Z = 32), Si (Z = 14) and O (Z=8) [34]. For a low-Z atom such as Si or O, the back-scattering amplitude has a large value in a small k-region which sharply reduces intensity with an increase in k. For higher-Z elements, the amplitude extends to a high k-region: the back-scattering amplitude has a maximum at k -- 6 A-1 for Ge while two maxima at k ~ 3.5 A -1 and 10 A-1. A characteristic k-dependence of a back-scattering amplitude is often used to distinguish atom types. Equation (4-6) shows that the modulation has a fundamental frequency 2rj while the envelope reflects the k-dependence of the back-scattering amplitude I~(k,~)l. Thus the analysis of EXAFS is essentially a process to obtain structural parameters, Nj, rj and crj from EXAFS oscillations using known I~(k,~)l and qt(k) as a function of k. Conventionally, the experimental phase shift is determined by fitting Eqn. (4-6) to the data of an appropriate model compound with a known structure.
20
1.2 1.0
i
... I0'
0.8
In
In
~0.6
Eo o
0.4
Ge
0.2 -I0 10 .-.
o
8
"-"
6
e-
0
In
10
k (~-i)
20
Ge
4 "
20
Si
!
0
I
10
!
20
k (~'~)
Fig. 4-6. Calculated back-scattering amplitude I~(k,~z)l as a function of k (A-1) and phase-shift functions for various scatterer atoms 9taken from ref. 34.
217 The details of data analysis are described in Section 4.4. Here, some important aspects of Eqn. (4-6) are summarized. First, the effect of multiple scattering is large in the low-k region where photoelectrons are strongly scattered. Figure 4-7 illustrates the scattering pathways for the three atom system which originates from the excited atom (0), scattered by the nearestneighbor atom (1) and the second-nearest neighbor atom (2). fl denotes the angle between the pathways (0-1) and (1-2). The strong forward scattering by a low-Z nearest-neighbor atom affects the magnitude of scattering by the second-nearest neighbor atom when the central atom, nearest neighbor and second-nearest neighbor atoms form a triangle. In general, for high energy electrons (kr >> 1), the magnitude of back-scattering is much smaller than that of forward scattering. This is the reason why the multiple scattering is not important in EXAFS at least for the nearest-neighbor, in contrast to low energy electron diffraction (LEED) where multiple scattering must be taken into account. In LEED, the electrons are irradiated outside the surface and the interference between forward-scattering photoelectrons is monitored by a detector placed away from the scatterer, while in EXAFS, the absorbing atom emits the photoelectrons and simultaneously detects the interference of back-scattered waves coming back to the origin. Secondly, in EXAFS, the interference pathlength of multiple scattering is long and the high frequency sin(2kr) oscillations due to multiple scattering cancel out. Actually, possible combinations of multiple-scattering pathways increase rapidly on going to higher shells beyond the nearest-neighbor atoms, and such long pathways would reduce the photoelectrons because of intrinsic and extrinsic inelastic scattering. These facts make the simple single-scattering EXAFS formalism valid for the nearest-neighbor atoms where the multiple-scattering pathways are separated in r. For multiple-scattering calculations, the spherical wave expansion [35] or small-atom approximation [36] can be used. However, there are several special cases where multiple scattering cannot be neglected [37,38]. In the low-k region, particularly for low-Z elements, the photoelectrons are strongly scattered and the multiple scattering becomes important. Thus, if a light-element atom is placed between the direct scattering pathways, its large scattering amplitude in the low-k region would enhance the multiple-scattering effect. As shown in Fig. 4-7, the strong forward scattering of
'
I
o
,2
92
(a)
--"" ,,/
0-2-0
o
2 (b)
0-I-2-0
. ....-" 1
(c) 0-t-2-1-0
o
Fig. 4-7. Schematic representations for scattering pathways (dashed line) for the three atom system which originates from the excited atom (0), scattered by the nearest-neighbor atom (1) and the second-nearest neighbor atom (2). fl denotes the angle between the pathways (0-1) and (1-2).
218 the intermediate atom (1) gives rise to a substantial multiple-scattering contribution along a triangle pathway (0-1-2). The effect of the multiple scattering is clearly seen in the Fourier transform of the Ga K-EXAFS oscillations measured for GaP, GaAs and GaSh (See Fig. 4-8). All three compounds have a zinc blende-type structure where each cation (Ga) atom is tetrahedrally coordinated by anion (P, As, Sb) atoms. In Fig. 4-8, although the second-nearest neighbors are twelve Ga atoms for all cases, the second-nearest peak observed around 4 ,/k is strongly dependent on the species of the first-nearest atom located at the apex of a triangle. A large second-nearest neighbor peak observed for GaP is due to the strong forward scattering power of the P atom. Thus it is clear that the analysis of the higher shells must take the multiple-scattering effect into account. With the decrease of t , the scattering by the secondnearest neighbor atom sharply increases due to the multiple scattering involving the nearestneighbor atom. Thus, when three atoms separated by an equal distance are linearly aligned, the second-nearest neighbor peak is observed with a magnified intensity, which is known as a focusing effect. The effect of multiple scattering can be corrected by a theoretical formula taking three pathways shown in Fig.4-7 into account. i
0.08 0.04 0 -0.04 -0.08
i
I
i
i
i
i
Go K- edge
1
V
0.04 0.02 0 -0.02 "" -0.04 >~ -0.06 0.08
0.04 0 -0.04 -0.08 2
fluorescence -t transmission z~ ~ ~ 10 1'2 14 16 18 k (~-1)
Fig. 4-8. Ga K-edge EXAFS oscillations as a function of photoelectron wave number k for GaP, GaAs and GaSb.
219 Atoms are vibrating around equilibrium positions which are usually displaced from ideal ones. The effect of dynamic and static disorder is described by the Debye-Waller-like term exp(-2o'j2k 2) for a harmonic oscillator with a Gaussian distribution. The displacement measured in EXAFS is the mean-square relative displacement between a central atom and a scatterer atom, in contrast to the Debye-Waller factor in the diffraction formalism, which measures the mean-square displacement. Physically, the mean-square relative displacement oj 2 includes the correlation term which vanishes for independent motions [39].
aj 2 =<[rj.(uj - u0)]a>
(4-8)
where uj and u0 denote the displacement vector for scattering and absorbing atoms originating from the thermal equilibrium positions. Based on various lattice dynamical models, o] 2 can be calculated [40,41 ]. If the phonon spectrum obtained by neutron diffraction measurements is available, trj 2 can be obtained [39]. Simple approximations based on a Debye model [39] or Einstein model [40] are often used for convenience. In order to describe the disorder by the exp(-2o'j2k 2) term, it is assumed that atoms are harmonic oscillators with a Gaussian distribution. However, for highly disordered systems the Gaussian distribution must be replaced with a pair-distribution function gij(r). It should be noted that the effect of disorder gives rise to the additional term in the total phase [42]. Even a symmetric gij(r) results in an additional term in phase. Since the integral over r, the pairdistribution, cannot be obtained in a straightforward manner such as a simple Fourier transform, a cumulant expansion of the pair-distribution function is used. One of the most difficult problems in EXAFS theory is the inelastic effect, i.e., energy loss. The many-body effects were discussed by Lu and Rehr [43]. In general, a simple simulation based on Eqn. (4-6) has a smaller amplitude by a factor of 0.1-0.4. This reduction of amplitude arises as a result of inelastic effects, (1) around the excited central atom via a multielectron process, or (2) associated with the scatterer atom, and (3) the inelastic effects of photoelectrons which are taken into account by an exponential decay term exp(-2rj/2,j) in Eqn. (4-6) using 2.j, a mean free path of a photoelectron. Since the proper theoretical estimation of (1) and (2) is difficult at present, in order to correct the amplitude reduction a simple constant is used in a conventional data analysis. Stern et al. introduced a damping factor S02 to account for an overlap of the initial and final wave functions of passive electrons which decrease the oneelectron matrix element [44]. The calculated S02 factors lie in the range 0.6-0.9 [45]. Since this value is dependent on both k and chemical bonds, it is reasonable to treat it as an empirical parameter. The contribution to the inelastic scattering within the back-scattering atom is included in the scattering amplitude using an optical potential whereas the inelastic effects at the central atom are accounted for by the S0 2 factor. Thus, adding an S0 2 factor should be associated with replacing the exp(-2rj/Zj) term with exp(-2(rj - A)/2,j) where A accounts for the
220 energy loss already accounted for in the S02 term. It should be noted that the mean free path between the first and second shells is not modified because the energy loss suffered by photoelectrons between the first and second shells is described by the mean free path term. Readers should refer to theories on intrinsic [46] and extrinsic [47] energy losses and optical potential [48] for a detailed discussion on many-body effects.
4.2.2. X-ray absorption near edge structure (XANES) The near edge structures (XANES) observed up to about 50 eV above the absorption edge have oscillations with much higher frequencies than EXAFS. They are caused by multiple-scattering resonances of photoelectrons within a cluster around an excited atom. Because of the lifetime broadening and solid-state effect, the energy resolution of 1-2 eV is sufficient for continuum features in most cases. Figure 4-9 shows typical XANES spectra on the Ge K-edge (11.11 keV) for crystalline and glassy GeO2, where a transition from the ls to 4p* states is observed as a sharp "white line" at the threshold. Several characteristic features are observed for both the crystalline and glassy phases although they are broadened in the latter. In general, the magnitude of XANES modulation is larger than that of EXAFS since the scattering factor is larger in a low energy region. As will be shown in Section 4.5, the analysis of EXAFS data shows that the short-range order within a GeO4 tetrahedral unit is strictly maintained in the glass although the long-range order is degraded. This indicates that the near-edge features are dependent on atomic arrangements beyond the first-nearest neighbors. As "slow" photoelectrons are strongly scattered, the multiple scattering is dominant in the near-edge region. Since the multiple scattering is sensitive to the bond angle, this means that the information on the bond angle as well as bond length is contained in the near-edge features. I
'
I
/.~'\
I
"i
'
i
'
I
i
Ge 02
,.....
Ge K-edge
--
f,,\\
o:>-
I\
trigonol ( z = 4 )
...... glass
\
(z 61
rren
I
-I0
l,.,
I
0
t
I
,
I
10 20 ENERGY leVI
i
I
30
'
9
40
Fig. 4-9. High resolution Ge K-edge XANES spectra for trigonal and glassy GeO2, taken on a spectrometer using a Si(311) channelcut crystal monochromator 9from ref. 11.
221 The scattering of low-energy electrons is sensitive to the shape of potential. This gives rise to sensitivity to chemical bonds or valency. However, these make it difficult to analyze the XANES by a simple method as in the case of EXAFS, although it has rich information on site symmetry and electronic states. In order to calculate XANES, multiple-scattering pathways must be taken into account. In fact, the state density of conduction bands for the 3d transition metals reproduces the experimental absorption curves for both XANES and EXAFS regions. The band calculations are equivalent to calculating all possible multiple-scattering pathways based on the long-range order or Bloch theorem [49]. The method of calculating multiplescattering paths is essentially the same as that for dynamic LEED intensity calculations. The number of possible pathways increases rapidly on taking outer shells into account and various approaches for full multiple-scattering calculations have been proposed [50]. For molecules, excited photoelectrons sometimes form a strong "shape resonance" state, giving rise to sharp transitions in the near-edge spectra [51], while insulators such as alkali halides show an exciton-like bound state transition [52]. Calculations of XANES using a molecular orbital approach have also been proposed [53]. Furthermore, features related to bound-state transitions are often observed below and above the absorption edge. In Fig. 4-10, polarized XANES spectra are shown for single-crystal La2CuO4 (above) and for a powder sample (bottom) [54]. The strong, polarization-dependent features observed for the single-crystal data arise from the anisotropic coordination geometry of square-planar Cu atoms in the CuO2 plane. In La2CuO4, the Cu atoms are four-fold coordinated by oxygen atoms at ~1.9 A in the basal plane. They are coordinated by two other oxygen atoms at ~2.4 ,~, forming a CuO6 octahedron distorted along the c-axis. The in-plane features are due to the bound-state transition from the ls to 4p*(cr) states while the out-of-plane features are the Is to 4p*(zr) transitions. These features correspond to the fine structures in XANES for powder La2CuO4, where anisotropic features are averaged out. The polarization dependence thus provides not only the information along a particular direction but is also helpful for the assignment of the near-edge features. It was pointed out by Natoli that the energy positions of these fine structures are related to the bond length [55]. As shown in this figure, the polarization-dependent out-of-plane features are sensitive to the ligand along the caxis. One can thus obtain the information on the apical-oxygen position from the out-of-plane polarized XANES. In high Tc superconductors, it is recognized that the apical-oxygen affects the superconducting properties and their role in the pairing mechanism is important. The recent development of the full multiple-scattering approach made it possible to analyze XANES and to obtain information on subtle changes in coordination, bond length, effective charge, or valency.
222
Cu K-edge 41~{r) O ? Is-41)'Io'I k[--~ d
Is-
~
A rE') I---
e
z >.cIc cIc
Lo2Cu04
Singlecrystal
~k'/O:9O~
g
k~
n...._~ ix..
! I I I I 8980 8990 9000 9010 9020 9030 9040 ENERGY (eV) Fig.4-10. Polarized Cu K-edge XANES spectra of La2CuO4 taken for a single crystal (above 9 from ref. 54) and unpolarized data for a powder specimen (bottom).
4.3. E X P E R I M E N T A L 4.3.1. Transmission
TECHNIQUES
XAFS
Monochromator
Classical X-ray absorption spectroscopy uses the transmission experiment, where a monochromatized X-ray is passed through a sample and from the incident and transmitted beam intensities the absorption coefficient p(E) is obtained as a function of the photon energy, E. In order to obtain the spectrum, the Bragg angle 013 of the monochromator is scanned. For Bragg reflections with dhkl, the energy of the incident beam E is given as
Ehkl = 12.4/~,hkl = 6.2/[dhkl sin0B] (keV)
(4-9)
223 The energy resolution AE/E is a convolution of the Darwin width ~50w and geometrical resolution of the incident beam ~50gwhich are determined by collimating optical components, a source size and an angular divergence. Since the polarization for a bending magnet radiation is horizontal, the vertical emittance is a dominat factor. AE/E is expressed by the following equation.
AE/E = [(~50w)2 + (~50g)2]1/2 cot 013
(4-10)
The vertical angular divergence of synchrotron radiation is an order of magnitude larger than the width of the rocking curve. For Si(111), 80w is ~8 sec or 1 x 10-5 rad for 8 keV Xrays while the vertical divergence is ~ 3 x 10-4 rad for the 2.5 GeV storage ring at the Photon Factory. Since the angular divergence is larger than the Darwin width roughly by an order of magnitude, it is necessary to collimate the beam either by a slit or a mirror. A typical energy resolution for Si(111) is ~2 eV at 9 keV when a slit with an aperture of 1 mm is placed before the monochromator located ~25 m from the source point. From Eqn. (4-10), the energy resolution increases with the increase of photon energy, and for high-photon-energy experiments, reflections with a smaller dhkl value such as Si(220) or Si(311) are used. Figure 4-11 shows a schematic representation of a variable-beam-height double-crystal
reflected beam stepping motor i
Oa 72
Y-translation
stepping L motor
\ ~
rotatingtable
Fig.4-11. Schematic diagram of a variable beam-height double crystal monochromator. The first crystal is placed on a computer-controlled XY stage. When the XY stage is controlled according to simple functions of the Bragg angle (see text), the output beam height is kept constant on rotating the axis.
224 monochromator. On rotating such a monochromator, the output-beam-height varies as a function of the Bragg angle. Various schemes have been proposed for achieving a constant output-beam-height [56]. The dominant source of experimental error in XAFS experiments is the systematic error which is caused by the fluctuations of beam positions due to monochromator scanning and the light source instability. In most cases, the mechanical stability in the parallel setting of the two crystals is the most important factor. In Fig. 4-11, the incident beam irradiates the center of the first crystal while the second crystal is placed on an XY stage. In the original design, a mechanical linkage was used for controlling the XY stage [57]. By replacing a mechanical linkage with computer control, the vertical position of an output beam can be controlled easily [58]. It should be noted that the dominant source of error in the parallel setup of the two crystals is the wiggles of X stage since the magnitude of the X-stage motion is larger than that of the Y-stage motion by an order. Figure 4-12 shows the positions of an XY stage as a function of the Bragg angle for Si(111) which achieve a constant output-beam height. E (keY)
Si(111) 100
Si (220)
151311109 8 7 6 t~,ll,l,~,l,l, l, ~ , z~181614151211 10 9
/
5 '
~}
"~
4 ~
6
3.5 ,
'51
3 J
Position of XY stage H=25mm
90 80 .-. 70E E "-" 60'~ 50-
>X
o 40r o
= 30-
o
20-
Y=H/2cos8
100
I
5
I
10
I
15
I
I
20 25 8 (deg.)
I
:30
I
35
410
Fig.4-12. Positions of the XY stage as a function of the Bragg angle for Si(11 l) which achieve a constant output-beam height.
225 HUTCH
Be WINDOW SLIT I SOURCE UHV POINT
MONOCHROMATOR
He
AIR
IF~I
SAMPLE
MASK
I,ON IONON , l CHAMBERII ll IICHAMBERIICHAMBER
li X"
SHUTTER
i STAGE ITO PZT
1
FEEDBACK ELECTRONICS
IV AMP i
VFC II~COUNTER I
POSITION
VFC I COUNTER I
I
MONOCHROMATOR
IV AMP
COMPUTER
STAGE
POSITION
Fig.4-13. Experimental scheme for XAFS measurement in a transmission mode. Intensities of the incident and transmitted beam are measured by the two ionization chambers as the photon energy is scanned. In this system, the vertical positions of the two ionization chambers and the sample are controlled by a lifting stage so that the beam irradiates the same position. Absorption spectra are obtained by dividing i0 by i and taking a logarithm according to Eqn. (411). The second term in Eqn. (4-11), which varies smoothly with photon energy, derives from the absorption of the two ionization chambers. Although this does not affect the normalization of EXAFS, it can be estimated from a simple measurement for a blank sample, if necessary. Higher harmonics and sample inhomogenity severely degrade absorption spectra [59]. Higher harmonics arising from higher-order reflections can be minimized by either a mirror or detuning the two monochromator crystals. For a typical X-ray mirror, varying the grazing angle can select the cut-off energy, above which the reflectivity rapidly decreases. Detuning the two crystals is a simple method for elimination of higher harmonics but it also loses beam intensity, and the random error increases.
4.3.2. Special techniques Fluorescence XAFS
Fluorescence detection [22] is a technique for increasing sensitivity for dilute samples. In a transmission experiment for a dilute sample, the thickness of sample is adjusted so that the edge jump is, but the transmitted beam intensity is exponentially attenuated while the ratio for the element of interest to the total absorption increases linearly. Thus the signal-to-noise ratio
226 rapidly decreases on increasing the total absorption since the signal (absorption) is proportional to the number of absorbed photon, which is a linear function of thickness, while the transmitted beam intensity decreases exponentially. As fluorescence and Auger yields are proportional to the absorption coefficient, these quantities provide alternative means to monitor absorption spectra. The distinction between these two methods arises from a difference in escape-depth. The fact that Auger yield is surface-sensitive is utilized in surface XAFS, while the escapedepth for the fluorescence X-rays is of the same order as the penetration depth of the incident beam. Above the absorption edge energy, the fluorescence X-rays are ejected and the fluorescence intensity I(E) accepted by a detector with a solid angle 12/4n is expressed by the following formula as a function of photon energy E,
I(E) = #(E) e ~ [I0 exp(-#T(E)t)) exp (-~tT(Ef) (sin0/sinr t ] dt dl2/4rc = I0 bt(E) e cosec0 j" [ 1- exp (- (,uT(E) cosec0 +/~T(Ef) cosec~) a)] dl2/4n; / [ktT(E) cosec0 + btT(Ef) cosecr ]
(4-12)
where I0 is the incident beam intensity, e is the fluorescence yield, p(E) and pT(E) are the absorption coefficient for an excited species and the total absorption coefficient, respectively; tx is the sample thickness, Ef is the energy for the fluorescence X-ray, 0 is the angle between the sample surface and incident beam, and r is the angle between the detector and sample surface. For bulk dilute systems where (pT(E) cosec0 + pT(Ef) cosec~) t~ << 1 (dilute limit), Eqn. (4-12) reduces to the following equation [60] :
I(E) .... S I0 #(E) e cosec0 dl-2/4n: / [pT(E) cosec0 + pT(Ef) cosec~ ]
(4-13)
Thus the fluorescence yield is proportional to the absorption coefficient and Eqn. (4-13) shows that the intensity is maximized as sin0/sin~ is minimized and 12 is maximized. However, the signal-to-scattering ratio degrades if s is simply increased. On the other hand, for a ~ 0 (thin-film limit), Eqn. (4-12) is approximately given by
227 I(E) ... ~ I 0 t.t(E) e cosec0 dl-2/4~
(4-14)
It should be noted that Eqn. (4-14) shows that the intensity is proportional to 1/sin0 but is not dependent on r suggesting that the intensity is gained by a grazing incidence angle. In both the dilute and thin-film limit, the incidence angle should be minimized. This is one of the reasons why a high brilliance X-ray beam is important in fluorescence detection. Figure 4-14 shows a typical energy spectra for fluorescence X-ray excitation. In general, the elastic scattering peak shifts to higher energy when the monochromator is scanned, and the characteristic X-ray lines with a fixed energy appear as the primary beam energy exceeds the absorption edge. In a fluorescence detection, the dilute limit is determined by the energy resolution of a detector and, conventionally defined as the signal-to-background ratio, is nearly unity. Other characteristic lines in a system, and the elastic and inelastic scattering, are sources of background. One can reduce the intensity of scattering by an order of magnitude by inserting an X-ray filter which has the absorption edge between the characteristic line and the elastic peak. Conventionally, a thin metal foil or a homogeneous powder containing the (Z-l) element is used as a filter [61 ]. An ionization chamber [62] or a scintillation counter array [63] are used in combination with a filter. Figure 4-14 shows the effect of an X-ray filter in reducing the elastic scattering background. This method, however, cannot remove the other characteristic lines because of an insufficient energy resolution. A solid-state detector (SSD) can remove the
ELASTIC
Go Si
A
0 0 0 ...-.
x .......
>.1
without Zn filter
t--
c-
GoKa ZnK..AKe/.,~wi,h Zn filler Channel number
2047
Fig.4-14. Fluorescence X-ray spectrum for Ga impurities in Si. The elastically and inelastically scattered photons and characteristic X-rays from other elements which have lower absorption edges are the source of background. Using an X-ray filter, the intensity of scattered photons can be reduced.
228 background although the count rate is limited by detector electronics. A multi-element SSD can enhance the count rate by an order of magnitude [64]. Although defined by signal-tobackground ratio, the dilute limit is practically determined by a detector count-rate and incidentbeam-intensity. Figure 4-15 shows the Zn Kt~ fluorescence yield for thermolysin + L-valyl-Lleucine measured using a scintillation counter array. It should be noted that a high signal-tobackground ratio is achieved. In some case, the self absorption cannot be neglected, and several procedures for correction have been proposed [65,66].
Zn K-edge
Thermolysin + L-volyI-L-leucine A If) t-:3 ..c:i t_
__.o LL.
9.7
9.8
I
I
I
9.9 10.0 10.1 Photon Energy (keY)
I
10.2
10.3
Fig.4-15. Zn K-edge fluorescence yield spectrum for +L-valyl-L-leucine measured with a NaI scintillation counter array.
Dispersive XAFS In an energy-dispersive mode [ 14,67-70], X-ray absorption spectra are measured as a spatial distribution of dispersed X-ray beam intensity. A bent crystal monochromator is used to disperse the X-ray beam and a position-sensitive detector is used to record the incident or transmitted beam simultaneously. The arrangement of an energy-dispersive spectrometer [14] is schematically illustrated in Fig. 4-16. A linear photodiode array with 1024 sensor elements separated by 25 ~tm is used as a position-sensitive detector. Various phosphor materials, such as YVO4:Eu and Gd202:Tb are used to convert hard X-rays into visible photons [68,71]. The most sensitive method is to irradiate the sensor with X-rays peeling off the optical window, although the direct exposure causes some radiation damage to the sensor element [69]. Figure 4-17 shows the Fe K absorption spectrum for iron foil measured by a linear photodiode array (RETICON RL1024SF) in an energy-dispersive geometry. The extracted EXAFS oscillations are shown in Fig. 4-18 for various exposure times. In this Figure, the results of a conventional step-by-step scan are also shown for comparison. Except for slight differences in magnitude
229 CURVEDCRYSTAL ,
SLITS
FROMSYNCHROTRON RADIATION SOURCE
/~
~j;.......~J~'~^ /Y~ " SAMPLE / ~
/
/
MIRROR
i I/
/
/
\
X-RAY FILM OR POSITIONSENSITIVE DETECTOR
_ \
\
ROWLANDCIRCLE~f\
Fig.4-16. Schematic diagram for energy-dispersive X-ray absorption spectroscopy (ref. 14). Incident and transmitted photons with various energies are focused at a sample position and simultaneously detected by a position detector.
due to a nonlinearity of the photodiode array, the results for the two modes agree well. It is noted that the one shot experiment with a 35 msec exposure gives essentially the same EXAFS features with those of a conventional method, indicating a small systematic error, which is the advantage of this method. As noted already, mechanical instability is the dominant source of systematic error. In an energy-dispersive mode, the primary source of error is a statistical one.
Fe EXAFS 55msec x 100
=< I--
z
I
I
I
I
I
I
I
I
7200 7500 7400 7500 7600 7700 7800 7900 ENERGY (eV) Fig.4-17. Fe K-edge absorption spectrum for iron foil taken in an energy-dispersive geometry. A self-scanning photodiode array is used as a linear detector with 50 lxm spatial
resolution.
230 l
J
i
,
i
i
"'
Fe K-edge
0.1 0.05 0 -0.05 -0.1
0.1 z ......
0.05 0 -0.05 l
0.05 0 -0.05 -0.1 I
4.0
I
6.0
I
8.0
!
I0.0
I
12.0
I
14.0
16.0
Fig.4-18. Fe K-EXAFS oscillations measured by an energy-dispersive method for iron foil, with various exposure times. The spatial resolution of a linear detector is mainly influenced by the cross-talks and broadening in a phosphor (--50 l.tm). The total energy resolution is a convolution of the source size, divergence and spatial resolution of the detector. Although the geometrical energy resolution is 1.73 eV for a Si(111) crystal with R = 2460 mm, the total energy resolution is --5.6 eV at 7.1 keV. A better energy resolution (2 eV at 9 keV) is achieved by either a direct exposure of the photodiode or a Si(311) bent crystal. The energy-dispersive geometry is particularly important for small samples, such as a diamond anvil apparatus for high pressure. Recently, it was shown that a small focus size (~100 ~tm) is obtained using an elliptically-bent crystal. In a time-resolved experiment, the time-resolution is dependent on photon statistics, and is of the order of a second for phosphor-coated photodiodes, while it can be decreased by an order of magnitude for direct exposure. Further, for an experiment which can be repeated, the time-resolution is reduced by several orders of magnitude. A fast chemical reaction in solution was recently studied by a stopped-flow experiment with a 25 milli-second time
231 resolution. Figure 4-19 shows the time-dependent change of Fe K-XANES associated with a chemical reaction in solution with a time scale of 10 msec [72]. The time-resolution limited by photon statistics will be improved by more brilliant photon sources, such as a multipole-wiggler or an undulator if the response of a position detector is sufficient enough.
i
!
,
,
|
|
i
i
Fe K EXAFS e
. ~ /
71oo
I
I
i
O.SM C6H4(OH)2 d e
/// /// J//
71 o
i
O.SM Fe(N03)3 +
oo
%
i
b: 100 C: 250 d: 550 e:1150 I
71:4o
I
71' o
I
71 o
PHOTON ENERGY (eV)
I
msec msec msec msec
72'00 7220 1
Fig.4-19. Time-resolved Fe K-edge XANES spectra after mixing 0.3 M ferric nitrate and 0.3 M hydroquinone. Curves a, b, c, d and e are the spectra taken by integrating the signal during the periods of 0-25, 75-100, 225-250, 525-550 and 1125-1150 ms following the mixing: from ref. 72.
Surface-sensitive XAFS In a hard X-ray region ( > 4 keV), because of the large penetration depth (of the order of a micron) absorption experiments are not surface-sensitive. In order to apply the XAFS technique to surfaces and buffed interfaces, a surface-sensitive detection scheme is required. As discussed already, fluorescence detection [22] is a highly-sensitive technique but it is not surface-sensitive in a hard X-ray region because the fluorescence escape-depth and the penetration depth of incident photons are of the order of one micron. However, surfaceselective excitation is made possible by a grazing-incidence geometry [73] illustrated in Fig. 420. Below a critical angle for the total reflection (0 < ~ ) , X-rays are totally reflected as they cross the interface between the two media, reducing the extinction length by several orders of
232 8>>8c Fluorescence
Photons Reflected
X-rays~
\ photons P~otoelectrons \
-
X-ray penetration depth
.
,.,
() \
x..,
" ,.~ l ~Electron I ~escapedepth /~-2 I
V/ " \~,( (~_===~' ....
8<~c
L)
~
~
z
~
_~.~~;~.~" X-roy " penetration depth
~-"~ I
L
Ix- raY
lescapedepth
Fluorescence
X-rays
~__.~eEIsecCa~re~p,h IY .... I~ "~do,~.,,,, i ~,--w - ~ v , -
Fig.4-20. Schematic representations of the normal (above) and surface-selective (bottom) excitations. The grazing-incidence geometry can reduce the probing depth by orders of magnitude, achieving a surface-selective excitation. magnitude, which enhances the surface sensitivity by the same amount [74]. Although the capability of surface-sensitive XAFS using a fluorescence detection and a grazing-incidence geometry has been demonstrated, a conventional method using a large-area fluorescence detector such as an ionization chamber has limited the application to non-crystalline or polycrystalline specimens because of a diffraction problem. Recently, it was shown that a combination of grazing-incidence geometry with an energy analysis using a solid state detector (SSD) which can discriminate a fluorescence signal from a background scattering can dramatically improve the surface-sensitivity, allowing us to apply this technique to studies of epitaxial layers on single crystal substrates [75]. Figure 4-21 shows a schematic geometry of surface-sensitive XAFS experiments [76]. Because of polarization dependence, the two orientations of specimen, i.e., a vertical mount and a horizontal mount, provide the information on the radial distribution around an excited atom, parallel and perpendicular to the surface normal, respectively. Since a typical critical angle for the total reflection of Si at 12.3 keV is --3.5 mrad, a high resolution goniometer with translational adjustment capability is used to control the incidence angle. The vertical divergence of incident photons is limited by the slits (--50 ~tm) placed in front of a beam monitor so that
233 only a central region of a specimen (15 mm x 15 mm) is irradiated. In Fig. 4-22, the incidentangle-dependence of a fluorescence spectrum is shown schematically. On decreasing the angle of incidence, 0, the fluorescence signal increases. Below the critical angle 0c, the inelastic scattering peak drops sharply in intensity. A single-element Si(Li) SSD subtends a solid angle
Reflected beam monitor
z
_
z
,--.~/
tO
9~ S p e c i m e n
beam
Z X~ . . . . ~ Y
Vertical mount
~X Horizontal mount
Fig.4-21. Experimental arrangement for surface-sensitive XAFS by fluorescence detection. The grazing-incidence angle is monitored by the intensities of the fluorescence signal, elastic peak, and reflected beam" from ref. 76.
Or) Z
~.2.0
1313 13::: >-
.-'~~
Si/Get/Si (001) 12.50 keV
X
~1.5'
(,/") U,J I---
,,,1.0 UJ
"'0.5 0 __1 U_ I
-1
:
I
0
i
r ~ - - ~ - ~- -" ~-i--- ;
1 2 ANGLE (mred)
~.:e
Fig.4-22. Variation of fluorescence signal and reflected beam intensities for Si23/Gel/Si(001) as a function of angle between the incident beam and the surface 9taken from ref. 75.
234 of 1% while a multi-element SSD can improve the acceptance of detector by an order of magnitude. In this setup, the white X-ray beam is monochromatized by a fixed-exit doublecrystal monochromator [57] which horizontally focuses the output beam by sagittal bending of the second crystal. A typical photon flux N1011/photons/sec/mm2 with an energy resolution AE/E --2 x 10-4 at 9 keV is obtained at a normal-bending-magnet beamline at the Photon Factory. 4.3.3. Insertion devices in XAFS research
Beyond the limitations Synchrotron radiation from dedicated low-emittance storage rings are characterized with high quality of beam characteristics, i.e., long lifetime, stability and capability to provide high brilliance photons using various insertion devices. The sensitivity and time-resolution in fluorescence detection are determined by the incident photon flux and efficiency of the detector. One of the advantages of high-brilliance photon sources is the sensitive and rapid XAFS, i.e., data can be collected for more dilute samples using a smaller quantity with a better timeresolution. Insertion devices such as wigglers and undulators can increase the brilliance; a multipole wiggler inserted in a low-emittance storage ring provides more brilliant X-rays than bending-magnet radiation, by more than an order of magnitude over a wide energy range. The vertical angular divergence of a wiggler is, however, still larger than the monochromator acceptance by an order of magnitude. The mismatch becomes more serious in a glancing angle geometry for surface-sensitive experiments. Either a collimating X-ray optics or an ultra-low emittance storage ring would improve the mismatch. The advantage of an ultra-low emittance storage ring is obvious and its potential in acceptance matching will be discussed in Section 4.6. Here we focus our attention to the application of a multipole wiggler to XAFS researches at a low-emittance storage ring.
Multipole wiggler A multipole wiggler consists of an array of magnetic poles which locally bend electron/positron beam and highly directional radiation from each pole is added. Figure 4-23 compares the brilliance of bending-magnet radiation with that of 27-pole wiggler magnet inserted at the Photon Factory. This device can be used either as an undulator with a weak magnetic field (B0) or as a multipole wiggler with strong magnetic field. The magnetic field can be varied by changing a gap of magnet array. In a wiggler mode, the maximum B0 is 1.5 T [77], for which the total power is 5.44 kW. From the figure, an increase of brilliance by more than an order of magnitude is expected in a hard X-ray region (4-30 keV). Such a high power causes heat load problems for optical components which are irradiated with white X-rays. The thermal distortion of the monochromator crystal due to heat load deteriorates its throughput and
235
10,6 undulator mode 1st 1# 5
BL13 MPW wiggler mode 1.5T
o~
.~ 1014 C3
bending magnet
E E
.e 10~3 e,O or
~" 1012 Z _J _J
N 1011
1
1 ~ 10z 103 104 105 PHOTON ENERGY (eV) Fig.4-23. Calculated brilliance of a 27-pole wiggler (1.5 T) installed at BL 13 of the Photon Factory. For comparison, the calculated spectra for undulator radiation and normalbending-magnet radiation are also shown. The smooth function indicates the envelope of the fundamental peak as the undulator gap is varied. 10
0
angular divergence or energy resolution. Figure 4-24 shows a schematic representation of the plan view of the optics at 27-pole wiggler beamline at the Photon Factory. White X-rays pass through the water-cooled graphite absorbers and Be windows, absorbing 1/3~1/2 of the heat load, before irradiating a double crystal monochromator. The horizontal acceptance of the first crystal (3:1 focusing) is 4 mrad, which is sagittally focused to a 4 mm x 1 mm spot at ~36 m from the source point. For vertical focusing and rejection of higher harmonics, a bent Pt-coated fused quartz mirror is placed behind the monochromator. The total Fe Ket signal intensity from 500 t.tM myoglobin is 5 x 104 cps for B0 = 0.75 T, Is = 337 mA without focusing where Is denotes the stored current. The total count rate increased further by about 2.2 times with B0 = 1.5 T. By use of horizontal focusing, the flux would further increase by an order of magnitude, suggesting that maximum 106 counts per second is obtained for 500 l.tM biological samples. It is expected that the fluorescence detection
236 BL-13 branch beam line water-cooled monochromator be windows ~
\\
2oo~mx?
~
~
/
/
branch beam line shutters
r
A
Ir
_ . . . . . ._. . .
2 7- p o l e - - -
--..-7"/-/-- . . . . . . . .
_
JI
~1
eom width of magnetic pole : 12cm deflection parameter K : 0.M,,,25 magnetic field 0.02,-,1.5T 9 total power : 5.44kW (I.5T) _ power density: 2.3 kW/mradz (~ I I 5 10
monochromotor branch beam line shutters and slit assemblies I
15
I
20
I
I
25 30 Distance from the source point (m)
I
35
I
40
4=5
Fig.4-24. Optics of a 27-pole wiggler beamline. A sagittaUy-bent second crystal focuses the central beam horizontally while a bent fiat mirror focuses the beam vertically. can be increased by about three orders of magnitude by combining a multi-element solid state detector, a multipole wiggler, and focusing optics [78]. With this count rate, the main source of error is the systematic noise caused by various sources of instability. A continuous scanning monochromator [79] or energy-dispersive geometry [14] can provide a stable incident beamintensity, removing the mechanical instability of step-wise motion of the monochromator. It is also important to reduce higher harmonic contributions using mirrors which are enhanced for high magnetic fields. Thermal distortion of the first crystal which deteriorates the throughput by broadening the rocking curve is critically dependent on power and power density. The temperature gradient causes bending and local bump of diffracting plane as well as gradient in lattice spacing along the surface normal. More importantly for XANES, the deformed crystal results in the beampower dependence of energy resolution. The effect of heat load on the first crystal has been studied for various types of grooved Si crystals [80,81]. The recent studies indicate that the cooling efficiency of grooved silicon crystals can be improved by replacing a conventional semicircular cooling channel [80] with a fiat one with optimized dimensions [81 ]. The distance between the surface and the fiat water channel is 1 mm and the width of water channels and cooling fins is 0.6 mm. Using such an optimized grooved crystal, the energy resolution required for XAFS experiments (AE/E--2 x 10-4) was obtained within a limited power range (B0 < 1.25 T). In order to dynamically correct the deformation of a grooved crystal caused by
237 heat load and internal water pressure, several "adaptive" approaches are proposed for silicon crystal monochromators. The curvature of the diffracting plane for the first crystal is controlled by pushing the lower block parallel to the grooves, using a piezoelectric translator or air dumper, so that the rocking curve profile is independent of the beam power. Sagittal bending [82] is widely used to focus the multipole wiggler radiation, which extends over 4 mrad. The conventional sagittal bending used for horizontal focusing has a serious problem; the horizontal focus size depends on the radius of the bent crystal. In XAFS experiments, a constant focus size over a wide energy range (~1 keV) is required. In order to meet this purpose, some approaches to achieve an energy-independent focus-size have been reported [83]. Dynamic sagittal bending is a technique which keeps the focus size constant. There are several proposals, such as a translational movement of a monochromator [83] or a crystal bender using an inchworm motor [81 ].
Surface sensitivity Surface-sensitive XAFS experiments using a grazing-incidence geometry and a fluorescence detection requires high-brilliance beam. A combination of multipole wiggler and a multi-element SSD achieved sub-monolayer surface sensitivity [78]. Surface-sensitive XAFS with submonolayer sensitivity has allowed us to probe the atomic rearrangements on the surface upon layer-by-layer growth such as organometallic vapor phase epitaxy (OMVPE) or molecular beam epitaxy (MBE). In OMVPE, one of the epitaxial growth techniques for III-V materials, the exchange reaction on the first layer has been an important issue. For example, the surface exchange reaction of a group V element (As, P) during the epitaxial growth of InAs or InAsP alloys on InP substrates has been a serious problem from viewpoints of the atomic layer epitaxy (ALE) since such an exchange would degrade interface sharpness in chemical composition. In order to clarify whether the substrate P atoms exchange with As atoms when exposed to ASH3, surface-sensitive XAFS on the As K-edge was measured for an InP(100) substrate exposed to AsH3 for a very short period (0.5 sec). This experiment can be a critical test for surface sensitivity as the coverage of As is expected to be well below 1 monolayer (ML). In Fig. 4-25, the As Ktx fluorescence-yield spectrum for AsH3-exposed InP(100) is shown. The As coverage determined by comparing the fluorescence intensity with those for strained InAs layers grown epitaxially on InP(100) was ~0.1 ML. The k-dependence of EXAFS oscillations indicates that the As atoms are bonded with In atoms, which evidences that ~1/10 of surface P atoms are replaced by As atoms within a short interval of 0.5 sec [84].
238
As/InP(lO0) (,,,1014/cm2) 0.1 ML 300K
As K- edge 0.10 0.08 ._o U_
0.06 0.04
I
I
0'11.6
I
I
I
I
I
I
I
11.8 1 2 . 0 12.2 12.4
I
I
12.6
PHOTON ENERGY(keY)
I
I
12.8
I
I
13.0
Fig.4-25. As K-edge fluorescence yield spectrum measured in a surface-sensitive geometry using a 27-pole wiggler and a multi-solid-state detector (SSD) for 0.1 monolayer (ML) of As on InP(100). The As atoms substitute P atoms when the InP surface is exposed to AsH3 gas flow : from ref. 78. 4.4. DATA ANALYSIS 4.4.1. Initial data treatment
In this section, the fundamental data analysis procedures to obtain structural information, i.e., extraction of the EXAFS oscillations, Fourier transform and curve fit are described. Figure 4-26 illustrates the schematic absorption spectrum and extracted EXAFS oscillations. The pre-edge region of absorption spectra contains the absorption due to: (1), ionization chambers as beam intensity monitors; (2), higher shells and; (3), other elements in a system. For fluorescence yield spectra, the pre-edge region is a featureless background due to the scattered photons and fluorescence lines from higher shells or other elements which smoothly varies as the excitation energy is scanned. The signal-to-background ratio reflects the energy-resolution of a fluorescence detector. The pre-edge region for spectra measured with an SSD is usually negligibly small. The first step in data analysis is the elimination of the smooth background functions which can be extrapolated from the pre-edge region. The mass absorption coefficients vary as a function of photon energy given by
p/p = Z (Ci/13 + Di/1,4)
(4-15)
239
0, ....
~
~
~
_
k
#o
"M
/~
/VV
re-o~
absorption
E Fig.4-26. Schematic representations of an X-ray absorption spectrum measured by a transmission mode. EXAFS is defined as modulations of absorption normalized with a free-atom absorption for a particular inner shell. where ~, is the X-ray wavelength, p is the density and Ci, Di are coefficients of Victoreen's function given as a function of photon energy for a particular element i [85]. Conventionally, the background absorption is approximated by a simpler function such as aEfl where a and fl are empirical parameters determined to fit the pre-edge. Using tabulated values of coefficients Ci and Di and normalization of Eqn. (4-15) using the edge jump, p/p above the absorption edge can be generated and subtracted which varies according to Eqn. (4-15). This evaluation of background absorption is useful since it is valid for both transmission and fluorescence modes, which allows us to compare the fluorescence data with transmission data. If the composition is known, the only parameter is a thickness which is determined by normalizing Eqn. (4-15) with the net absorption defined as a difference between the pre-edge absorption and a smooth fleeatom absorption of interest. A free-atom absorption P0 can be evaluated by fitting a smooth function, such as a cubic spline, to the EXAFS oscillations. The normalized EXAFS oscillations are then obtained by normalizing the modulations of absorption coefficient which is obtained by subtraction of a flee-atom absorption.
z(k)
= AI~
I laO
(4-16)
240 where A# and/-tO are the magnitudes of modulation in # and atomic absorption, respectively. Figure 4-27 shows the normalized Ge K-EXAFS oscillations as a function of wave number of photon energy k for crystalline (solid line) and glassy (dashed line) GeO2 measured at 80 K (a), and 300 K (b). On reducing the temperature, the magnitude of oscillation increases as a result of temperature-dependent term in Eqn. (4-6) which describes thermal disorder. It is concluded that the glassy and crystalline GeO2 have a similar short-range order, since the fundamental EXAFS oscillations arising from the interference between the nearest neighbors are essentially the same for the two forms.
0.04
(a) 80K
GeO2
I
0.03 0.02 0.01 0.00 -0.01 -0.02 -0.03 Trigonol GeO2 Crystol
--- -0.04
,,_... X
(b) 300 K
GeO2 Gloss
0.03
0.02
0.01 0.00 -0.01 -0.O2 -0.03 -0.04 0
I
2
I
4
I
6
I
I
I
I
I
8 10 12 14 16 18
R(~I
Fig.4-27. Normalized Ge K-EXAFS oscillations for crystalline (solid line) and glassy (dashed line) GeO2 measured at room temperature and at liquid nitrogen temperature" taken from ref. 11.
241 4.4.2. Fourier transform
For a quantitative analysis in real space, or to filter out the contribution of a particular shell, the normalized EXAFS oscillations are Fourier-transformed according to the following equations.
F(r) = (1/2n) ~k z(k) w(k) exp(-2ikr) dk = (1/2n)
~k z(k) w(k) cos(2kr) dk - i (1/2n) ~ k z(k)
= Re
(4-17)
F(r) + i Im F(r)
w(k) sin(2kr) dk (4-18)
where w(k) is a window function in order to minimize the cut-off effects in the Fourier transform. Figure 4-28 shows the magnitude of Fourier transform IF(r)l of the Ge K-EXAFS oscillations for crystalline (trigonal) and glassy GeO2[11 ]. Several sharp peaks correspond to positions of near neighbor atoms of an excited atom, although its position is shifted to small R because the total phase shift g1(k) in Eqn. (4-6) is neglected. The first peak located around 1.7 A is due to the tetrahedrally coordinated nearest oxygen atoms while the second peak at ~ 3 ./k is due to the second-nearest Ge peak. In trigonal GeO2, Ge atom is located at the center of a tetrahedron in which four oxygen atoms occupy each corner. The GeO4 tetrahedra are connected each other sharing oxygen atoms. On going from a crystalline phase to a glassy one, the first peak does not change while the magnitude of the second-nearest neighbor peak decreases. This indicates that the short-range order within the GeO4 units is strictly maintained but connectivity is disordered in a glassy state. These results are consistent with the near-edge structure data. Figure 4-9 shows that the near-edge structures observed for a crystalline phase broaden in a glassy state but essential features remain unchanged indicating the conservation of the short-range structure. Following Eqns. (4-17) and (4-18), the region of interest in real space can be Fourierfilterd into k-space. Contribution of each shell is separated and a non-linear curve fit analysis is used to yield structural parameters. In order to determine the structural parameters such as coordination number, bond length and mean-square relative displacement, the total phase-shift function for each pair and the back-scattering amplitude functions must be known. There are several approaches to fit the experimental data with Eqn. (4-6). A total phase shift and a backscattering amplitude can be extracted empirically from a model compound data with a known crystal structure, on the basis of chemical transferability of these functions. If a model compound is not available, a theoretically-calculated phase shift and amplitude are used with a
242
(a) 80K
GeOz
(b) 30OK
Trigonol GeOz Crystol GeOz Gloss
..-...
..ci
0
1
4
5
0
1
4
5
Fig.4-28. Magnitude of Fourier transform of the Ge K-EXAFS oscillations for trigonal crystal and glassy GeO2 measured at room temperature and at liquid nitrogen temperature : from ref. 11.
slight adjustment of the E0 value to match the zero of muffin-tin potential. An alternative approach is the intermediate method which uses the experimental phase-shift function and theoretical amplitude as will be described in the next subsection.
4.4.3. Curve fit analysis The least-squares curve fit analysis is a procedure to fit the experimental data with Eqn. (4-6) with structural parameters as variables. The step is to filter out the first-shell contribution by a back-Fourier transform into k-space to yield the simple sinusoidal oscillations as a function of k. The total phase shift and back-scattering amplitude I~(k,Tt)] calculated using a curved wave method are plotted in Fig. 4-6. Clearly, ~j(k) and I~(k,,t)] depend on the atomic species and show characteristic k-dependence. The total phase shift ~(k)is approximated by a polynomial ~j(k). In order to extract the total phase shift from the reference data, it is parametrized in a simple formula such as,
tDi(k) = a0 + al k + a2 k2 + a3 k-3
(4-19)
243 where coefficients a0, al, a2 and a3 are adjusted so that the calculated EXAFS oscillation according to Eqn. (4-6) best fits the reference data using a least-squares method. In a curve fit to the experimental data based on a single-scattering formalism using a theoretical I~(k,n)l, two other parameters are introduced: the damping factor in order to account for the inelastic energy loss of photoelectrons, which apparently reduces the amplitude, and the disorder parameter which accounts for the relative displacement. Although the former parameter S02 is k-dependent, it is often approximated as a constant. Unlike diffraction experiments, oi in EXAFS is the mean-square displacement, which refers to a "relative" displacement between an excited atom and a scatterer atom. For a single shell, there are six parameters to be determined by a least-squares curve fit. If the reference material has a coordination geometry similar to that of unknown material, it is reasonable to assume that the empirical phase shift is transferable [86], although there is uncertainty in the amplitude, depending on the electronic states [87]. Figure 4-29 shows the Ga K-EXAFS oscillations for GaAs powder, plotted as a function of the photoelectron wave number k, in ,~-1 (above). The Fourier-filtered first-shell contribution (solid line) is compared with the results of a least-squares curve fit (dashed line) below.
/
0.06 0.04
Ge K-edge
..-. 0.02 "-"
0 -0.02 -0.04 -0.06 I
I
I
I
I
I
I
First shell t--
A
I
4
I
6
I
8
I
10 k (All
I
12
I
14
I
16
Fig.4-29. Ga K-EXAFS oscillations for GaAs powder plotted as a function of photoelectron wave number, k, in/~-1 (above). The Fourier-filtered first shell contribution (solid line) is compared with the results of a least-squares curve fit (dashed line) below.
244 4.4.4.
Disorder
A well-known single scattering expression of EXAFS, Eqn. (4-6) is justified for a case where the disorder is small enough to be approximated as a harmonic oscillator. Then, the distribution of atoms around an excited atom can be expressed by a Gaussian function. The mean-square relative displacement (MSRD), oij in EXAFS is the ensemble average, and is smaller than the sum of mean-square displacement (MSD), o52 + o] 2, by 2crio'j which expresses the correlation between an excited atom and a scatterer atom where o-12 and crj2 are MSD's for the i-th (excited) atom and the j-th (scatterer) atom, as expressed by the following formulae.
oij 2 = < [ R j . (uj - u 0 ) ] 2 > = < ( u 0 . Rj)2> + < ( u j . R j ) 2 > - 2 <(u0. Rj) ( u j . Rj)>
(4-20)
Here, Rj is the vector along the i-j bond and u0 and uj are displacement vectors for the excited atom and the scatterer atom, respectively, originating from the equilibrium positions. One can calculate the MSRD from a proper lattice-dynamic force model which describes the phonon distribution. A simple model such as the Debye model or the Einstein model, is used to evaluate the effect of correlation or a temperature-dependent dynamic disorder. In highly disordered systems, one must replace the Gaussian distribution with a pair correlation function gij(r) given by z(k) = -1/k ~ I~(k,rt)l [ gij(r)/r 2 ] sin(2kr + ~j(k)) exp (-2r/Aj) dr
(4-21)
It should be noted that even if gij(r) is symmetric with respect to r, the integration over r introduces a higher order term in the total phase shift function. Moreover, in general, gij(r) is asymmetric, reflecting the potential shape. Thus, neglect of the disorder-induced term in the phase would result in a smaller bond length. This effect can be corrected by a cumulant expansion [88]. Eqn. (4-21) can be rewritten as z(k) = -1/k I~(k,n)l Im [ exp i (2kr + ~ij(k)) exp {E ((2ik)n/n!) Cn}]
(4-22)
In most cases, it is sufficient to introduce C2 and C3 in order to correct the higher-order terms in amplitude and phase, respectively, where C2 and C3 are coefficients of cumulant expansion, determined by fitting the amplitude and phase part of Eqn. (4-6) to the data. The physical meaning of the second-order term is the thermal expansion. The relation between the thermal expansion coefficient, a, and the cumulants of the vibrational amplitude, has been elucidated by Frenkel and Rehr [89].
245
4.4.5. Multiple scattering The advantage of EXAFS is that the multiple scattering effect is negligibly small for the nearest neighbor, in sharp contrast to LEED which must take into account the multiple scattering. The difference arises from the fact that in EXAFS, the electrons are emitted as a spherical wave and the interference is detected, at the origin between the outgoing wave and back-scattered waves which are strongly damped because of inelastic energy loss. In contrast, in LEED the electrons come in and are reflected as a plane wave in a forward-scattering geometry. One of the reasons why the multiple scattering cannot be neglected in LEED is that the forward-scattering amplitude is large in low energy region. Since the total path length increases as a result of multiple scattering, the effect of multiple scattering is often observed in a low-k region as higher frequency oscillations than those for the nearest-neighbor spacings, and these oscillations rapidly damp, canceling out each other in EXAFS. In Fig. 4-7, the multiplescattering pathways are illustrated for the three atom (0-1-2) system. Photoelectron waves originate and are terminated at the excited atom, 0, after being scattered at other atoms (1, 2). In addition to the single scattering between 0 and 2 (a), a double-scattering path (0-1-2-0, b) and a triple-scattering path (0-1-2-1-0, c) are indicated. The multiple-scattering pathways would modify the amplitude and phase of EXAFS oscillations as a strong function of the geometry, and it is well known that the triple scattering is magnified for the case of a linear array (lens effect) in Fig. 4-7. It should be noted that the double-scattering is important for covalent materials with an sp 3 configuration, where the second-nearest neighbor-peak contribution depends strongly on the atomic species at the second-nearest sites. Figure 4-30 shows the Fourier transform of Ga K-EXAFS oscillations for; (a), GaP; (b), GaAs and (c), GaSb. All these materials have a zinc blende type of structure where each cation is coordinated by four anions as nearest-neighbor atoms and by 12 cations as the second-nearest neighbor atoms. Although the species of atoms at the second-nearest sites are the same for the three compounds, the peak profile at the secondand third-nearest neighbor atoms is quite different. This demonstrates that in this geometry, i.e., fl -- 71 o, the double-scattering pathways are strongly affected by the forward scattering at the second-nearest neighbor atom, and in particular for atoms with large scattering amplitude in the low-k region, such as P. In such a case, the multiple-scattering paths appear as shoulders with larger r, which makes the peak in the Fourier transform broader as shown in Fig. 4-30. 4.5. A P P L I C A T I O N S
4.5.1. Dopants in oriented polyacetylene Polyacetylene, (CH)x, has been extensively studied because of its unique properties as a conducting polymer when it is doped with electron donors or acceptors [90,91]. The electrical conductivity of pristine (CH)x increases by several orders of magnitude when it is doped with electrons as in AsF5, Br2, or 12 [92-94]. Transport, optical, and magnetic properties of these
246
K-edge GaP
A
e-
GaAs
r'r LI_
GaSb
012545678910
RC I
Fig.4-30. Magnitude of Fourier transform of the Ga K-EXAFS oscillations for GaP, OaAs and GaSb. On going from a light element scatterer (P) to a heavy one (Sb), the peak profile for the second-nearest neighbor (Ga) changes as a result of multiple scattering pathways via the first-nearest neighbor group VI atoms. systems were discussed in terms of solitons [95] or the spinless defect states resulting from the bond-alternation domain wall in a conjugated carbon chain. XAFS studies of doped (CH)x have been aimed at investigation of the local structure of dopants, in order to understand the mechanism of doping and the role of charged solitons. The structure of pristine trans-(CH)x was first determined by Baughman et al. [96] from the packing analysis of X-ray diffraction data, which was later refined by Fincher et al. [97] to provide direct evidence of bond alternation. For the case of iodine doping, a structural model similar to the first-