Ilse Zolle Editor
Technetium-99m Pharmaceuticals
Gedruckt mit Unterstçtzung des Bundesministeriums fçr Bildung, Wisse...
153 downloads
3080 Views
4MB Size
Report
This content was uploaded by our users and we assume good faith they have the permission to share this book. If you own the copyright to this book and it is wrongfully on our website, we offer a simple DMCA procedure to remove your content from our site. Start by pressing the button below!
Report copyright / DMCA form
Ilse Zolle Editor
Technetium-99m Pharmaceuticals
Gedruckt mit Unterstçtzung des Bundesministeriums fçr Bildung, Wissenschaft und Kultur in Wien und der Kulturabteilung der Stadt Wien, Wissenschaftsund Forschungsfærderung
Ilse Zolle Editor
Technetium-99m Pharmaceuticals Preparation and Quality Control in Nuclear Medicine With 66 Figures and 29 Tables
12
Ilse Zolle Department of Medicinal/Pharmaceutical Chemistry University of Vienna Althanstraûe 14 1090 Vienna Austria
Library of Congress Control Number 2006925440
ISBN-10 ISBN-13
3-540-33989-2 Springer Berlin Heidelberg New York 978-3-540-33989-2 Springer Berlin Heidelberg New York
This work is subject to copyright. All rights are reserved, whether the whole or part of the material is concerned, specifically the rights of translation, reprinting, reuse of illustrations, recitation, broadcasting, reproduction on microfilm or in any other way, and storage in data banks. Duplication of this publication or parts thereof is permitted only under the provisions of the German Copyright Law of September 9, 1965, in its current version, and permission for use must always be obtained from Springer-Verlag. Violations are liable for prosecution under the German Copyright Law. Springer is a part of Springer Science+Business Media springer.com ° Springer Berlin Heidelberg 2007 The use of general descriptive names, registered names, trademarks, etc. in this publication does not imply, even in the absence of a specific statement, that such names are exempt from the relevant protective laws and regulations and therefore free for general use. Product liability: The publishers cannot guarantee the accuracy of any information about the application of operative techniques and medications contained in this book. In every individual case the user must check such information by consulting the relevant literature. Editor: Dr. Ute Heilmann Desk Editor: Wilma McHugh Production: LE-TEX Jelonek, Schmidt & Væckler GbR, Leipzig Typesetting: K + V Fotosatz, Beerfelden, Germany Cover: Frido Steinen-Broo, eStudio Calamar, Spain Printed on acid-free paper
21/3100/YL
5 4 3 2 1 0
Foreword Some persons have thought that the increasing emphasis and development of positronemitting radiotracers in nuclear medicine would result in a decrease in the development and use of single photon-emitting radiotracers. That this is not the case is illustrated by the fact that there were 302 presentations involving technetium-99m at the June 2006 annual meeting of the Society of Nuclear Medicine in the United States. Iodine-123 accounted for 88 presentations, and indium-111 for 81. Among the most recent advances in the fusion of nuclear medicine images with computed tomography (SPECT/CT) and computed tomography angiography (SPECT/ CTA) in basic science studies in small animals, SPECT/CT was the topic of 11 instrumentation presentations, while PET/CT in small animals accounted for 5 presentations. The success of molecular imaging in medicine and biomedical research is the result of the diversity of imaging technologies, the integrating and collaboration of imaging and pharmaceutical development experts, and friendly competitition. The advantage of single photon tracers is that many of them, such as technetium-99m, emit only photons, rather than positrons or negative beta particles that increase the radiation exposure of the patient and limit the doses of the tracers that can be administered with acceptable radiation exposure. Also, the range of positrons in tissue before they encounter an electron and emit 511 keV photons limits the spatial resolution that can be obtained in living animals and patients. Theoretically, the spatial resolution of single photon tracer studies is limitless, especially with the use of special pinhole collimation. Radioactive tracers used in medicine today provide information, and need to be judged by how reliably they provide this information. Some of the safeguards built into the drug review process by the FDA for regulating pharmaceuticals are not needed in the case of the mass of injected material used in radiopharmaceuticals. With radiopharmaceuticals, the criterion should be whether the information provided by the diagnostic procedure is valid and valuable. Today, we need to promote a ªfast trackº regulatory approval process to make diagnostic procedures more readily available. A major difference between therapeutic and diagnostic drugs is that the efficacy of the diagnostic procedure in providing the required information can be assessed shortly after the performance of the imaging procedure. The patients do not need to be followed for longer periods of time to identify any untoward side effects. Multi-institutional randomized control studies can determine whether the procedure provides the diagnostic information provided by the study, as well as identify any untoward side-effects. Radiotracers, by definition, have no effect on the patients' biochemistry or body functions, which should be a major simplifying factor along the road to their regulatory approval. There is ever-increasing evidence of their great value in answering the questions: What is wrong? What is going to happen? What can be done about it? How did it happen? This book covers the past, present and future of single photon tracers in medical practice and biomedical research. It is likely to become a standard textbook for those persons entering the exciting career of a radiopharmacist or researcher in biomedical research using radioactive tracers.
VI
Foreword
The pathway to assuring the safe and effective use of short-lived radiotracers is to place the responsibility for quality assurance in the hands of nuclear pharmacists who fill physician's prescriptions for radiotracers as they do for other drugs under state pharmacy laws. Radiochemists or others working in institutions with radiopharmacies must have the expertise for the preparation of the radiotracers as well as for quality control under good manufacturing practices. This book provides guidance and safety standards applicable to Tc-99m pharmaceuticals. Baltimore, June 2006
Henry N. Wagner, Jr. M. D.
Foreword Viewpoint of the Clinician Radiopharmaceuticals labeled with 99mTc are commercially available and are employed in more than 80% of all nuclear medicine investigations. Among the radionuclides, technetium-99m is most attractive to the nuclear medicine physician because of its optimal gamma energy for SPECT, its availability, its relatively low cost, and its easy-to-label kit preparations for in-house use. Another advantage is the low radiation burden to patients, due primarily to its short half-life. The decay within hours also facilitates the handling of waste. Professor Dr. Ilse Zolle ± together with other leading international radiochemists and radiopharmacists ± made an effort to collect the available data on 99mTc-labeled compounds with respect to their chemistry, labeling methods, quality control procedures and clinical applications. The comprehensive text is presented in two parts. The first part comprises chapters on technetium compounds in medicine, including advances in labeling biomolecules with technetium, the advantages of sterile kit formulations, and analytical methods to verify pharmaceutical quality. Emphasis is given to the rules governing the manufacture of radiopharmaceuticals and the importance of specifications given by the pharmacopoeia, which are obligatory. A special chapter is devoted to the performance of the 99Mo/99mTc generator and to the characteristics of the 99mTc eluate. For the clinician, Part II offers 25 monographs relating to 99mTc-pharmaceuticals, which describe the pharmaceutical particulars of each radiotracer as well as relevant information on its clinical application, concerning the pharmaceutical dosage, contraindications and interference with other pharmaceuticals, quality control, pharmacokinetic data, radiation dose and valuable references. In addition, recommendations for storage and criteria of stability are also given. The multidisciplinary properties of 99mTc-pharmaceuticals are presented in the form of a highly structured text with informative tables, which enables the clinician to find clinically relevant data very easily. The book should therefore not only be recommended for radiochemists and radiopharmacists, but also for nuclear medicine physicians using 99mTc-labeled pharmaceuticals in daily practice. Wçrzburg, July 2006
Christoph Reiners
Preface 99m
Tc pharmaceuticals mark the beginning of diagnostic nuclear medicine and have contributed to patient care worldwide. Since the short-lived radionuclide was introduced for thyroid imaging in 1964, it has attracted much attention and stimulated clinical research. Little was known about element 43, except that it was an artificial radionuclide obtained by the radioactive decay of molybdenum-99. No wonder specialists from all fields joined medical institutions in the United States to participate in the exploration of its chemistry. This textbook gives an account of the accomplishments related to the development of 99mTc pharmaceuticals and their application in diagnostic nuclear medicine. Since radioactive drug development is a multidisciplinary task, experts working in nuclear medicine and research institutions have contributed valuable information concerning the preparation with sterile kits, methods of quality control, and the use of 99mTc pharmaceuticals in patients. In addition, the legal aspects governing production and clinical application are also considered. 99m Tc pharmaceuticals in nuclear medicine are presented in two parts. Part 1 includes basic principles and methods used for preparation and analysis, in particular the chemistry of technetium-99m and methods described for the synthesis of complexes and conjugates of technetium-99m, the characteristics and performance of the 99 Mo/99mTc generator system, the importance of kits and formulations for one-step labeling, and safety aspects for labeling blood cells. Special emphasis is given to analytical methods verifying pharmaceutical quality. The quality standards of good manufacturing practice (GMP) for 99mTc pharmaceuticals and purity standards of the pharmacopeia (European Pharmacopeia and United States Pharmacopeia) have been considered as part of the concept of quality assurance. Part 2 presents 26 monographs of 99mTc pharmaceuticals, concerning the preparation and safe clinical application. Each monograph provides information on the characteristics of the radiotracer based on chemistry, factors affecting the preparation and in vivo stability, pharmacokinetics and elimination properties, as well as details concerning the clinical application. For each clinical procedure, the effective radiation dose of the patient has been calculated. Methods recommended for quality control and actual results are included. Each radiopharmaceutical is listed under the name used in daily practice. The chemical name, the abbreviated name, and the officinal name in the pharmacopeia are also stated. Listing the trade names may facilitate understanding, especially when relating to products in the literature, which over the years have changed manufacturers. The presentation of 99mTc pharmaceuticals as monographs serves a practical purpose: it offers relevant information on kit preparation and clinical application at a glance. These monographs provide a wide spectrum of information on 99mTc pharmaceuticals for daily practice in nuclear medicine, serving as a reference source as well as a teaching tool.
Acknowledgments Dr. Ferenc Rakis, Deputy Chief of Drug Quality, The National Institute of Pharmacy in Budapest, Hungary and Co-ordinator of a European Working Group on the Quality Control of 99mTc-Radiopharmaceuticals (COST Action B3) has gained high recognition for major contributions, which resulted from the collective effort of the Working Group. Based on studies of quality control methods, and a collection of manuscripts, Dr. Rakis and his dedicated staff have produced a first version of this book, documenting the multidisciplinary nature of the cooperation. The National Institute of Pharmacy in Budapest has also hosted most Working Group meetings, their hospitality is appreciated. The participation of Austrian scientists in COST Action B3 was supported by: The Federal Ministry of Education, Science, and Culture, actively promoted by: Dr. Norbert Rozsenich, Head, Section V, Commerce and Technology Hofrat Dr. Raoul Kneucker, Head, Section VI, Scientific Research and International Affairs Ministerialrat Dr. Helga Mieling, National COST Co-ordinator Dipl. Ing. Otto Zellhofer, Science, Energy and Space Program 'AUSTROMIR' Ministerialrat Alois Sæhn, Presidial Division 4 Hofrat Mag. Anna Kolde, and Regierungsrat Franz Gerersdorfer The Department of Nuclear Medicine and the Ludwig-Boltzmann-Institute of Nuclear Medicine, Professor Emeritus Dr. Rudolf Hæfer, and the Department of Biomedical Engineering and Physics, Professor Dr. Helmar Bergmann, all at the University Hospital AKH, Vienna. Editorial work was kindly supported by Hofrat Dipl.-Ing. Gerhard Wolf and his team, Mrs. Elisabeth Abromeit and Mrs. Sandra Jama The assistance of Dr. Yu Jie (Julia) and Mag. pharm. Georg Kropf is gratefully acknowledged.
Contents
Part I 1
2
Drug Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1.1
Quality Control and COST . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
1.2
Quality Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
1.3
Quality Assurance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
1.4
Quality Control of Kit Products . . . . . . . . . . . . . . . . . . . . . . . .
4
1.5
European Economic Community Directives and Regulations . . . .
5
Technetium in Medicine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
I. Zolle
2.1
99m
2.1.1 2.1.2 2.1.3 2.1.4
Technetium Compounds and their Structures Technetium(V) Complexes . . . . . . . . . . . . Technetium(IV), (III), and (I) Complexes . . . . 99m Tc Labeling . . . . . . . . . . . . . . . . . . . .
2.2
Technetium and Rhenium Tricarbonyl Core
8 9 17 20
..............
27
2.2.1
Bioconjugates Comprising the M(CO)3 Core . . . . . . . . . . . . . . . .
32
2.3
Technetium Coupled With Biologically Active Modules . . . . . . . .
40
2.3.1 2.3.2 2.3.3
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . Factors Affecting In Vivo Performance . . . . . . . . . . Chelate Units in the Design of Target-Specific 99mTc Pharmaceuticals . . . . . . . . . . . . . . . . . . . . . . . . Search for Novel Tc Pharmaceuticals . . . . . . . . . . .
.......... ..........
40 41
.......... ..........
42 46
Tc Pharmaceuticals . . . . .
59
3.1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
59
3.2
Stannous Chloride: the Preferred Reducing Agent for Tc Pharmaceuticals . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
61
R. Schibli
H.-J. Pietzsch, J.-U. Kçnstler and H. Spies
Stannous Chloride in the Preparation of
H. Spies, H.-J. Pietzsch
99m
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
. . . .
7
. . . .
2.3.4 3
Technetium Chemistry . . . . . . . . . . . . . . . . . . . . . . . . . . .
U. Mazzi
XIV
Contents
4
5
6
Quality Assurance of Radiopharmaceuticals . . . . . . . . . . . . . . . . . . .
67
4.1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
67
4.2 4.2.1 4.2.2 4.2.3 4.2.4 4.2.5
Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quality Assurance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Good Manufacturing Practice . . . . . . . . . . . . . . . . . . . . . . . Pharmacopeias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Approval for Marketing Authorization of a Radiopharmaceutical Quality Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . .
67 67 68 70 71 71
Mo/99mTc Generator . . . . .
77
T. Bringhammar, I. Zolle
. . . . . .
Performance and Quality Control of the
99
5.1 5.1.1 5.1.2 5.1.3 5.1.4
The Equilibrium State . . . . . . . Production of Molybdenum-99 . Separation Methods . . . . . . . . Design of the Generator Column The Generator Eluate . . . . . . . .
. . . . .
. . . . .
. . . . .
. . . . .
78 79 79 80 80
5.2 5.2.1 5.2.2 5.2.3 5.2.4
Performance of the 99Mo/99mTc generator system . . . . . . . . . Elution Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The Kinetics of Decay and Growth of the 99Mo/99mTc Generator Factors Affecting the Elution Yield . . . . . . . . . . . . . . . . . . . . Elution of Carrier 99Tc . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .
. . . . .
81 81 82 85 85
5.3 5.3.1 5.3.2 5.3.3 5.3.4
Purity of Generator Eluate (European Radionuclidic Purity . . . . . . . . . . . . Radiochemical Purity . . . . . . . . . . . Chemical Purity . . . . . . . . . . . . . . . pH of Eluate . . . . . . . . . . . . . . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
86 86 86 87 87
5.4 5.4.1 5.4.2 5.4.3 5.4.4
Methods and Results . . . . . . . . . . . . . . . . . . . . . . . Determination of the Elution Efficiency . . . . . . . . . . . . Determination of the 99Mo Content of the Eluate . . . . . Determination of the Radiochemical Purity of the Eluate Determination of the Chemical Purity of the Eluate . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
87 87 87 89 89
5.5
Conclusions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
90
I. Zolle
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
Pharmacopeia) ........... ........... ........... ...........
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
99m
Tc Pharmaceuticals . . . . . . . . . . . . . .
95
6.1 6.1.1 6.1.2
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Physical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chemical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
95 95 95
6.2 6.2.1 6.2.2 6.2.3 6.2.4
Kit Preparation . . . . . General Considerations Cold Kits . . . . . . . . . 99m Tc-Pertechnetate . . Incubation . . . . . . . .
95 96 96 97 97
Preparation of Technetium
J. Mallol, I. Zolle
.. . .. .. ..
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
XV
Contents
6.2.5 6.2.6 7
8
Quality Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dispensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
97 98
Lyophilization Technique for Preparing Radiopharmaceutical Kits . . .
99
7.1
History of the Lyophilization Technique . . . . . . . . . . . . . . . . . .
99
7.2
Principles of Lyophilization . . . . . . . . . . . . . . . . . . . . . . . . . .
100
7.3 7.3.1 7.3.2 7.3.3 7.3.4
Apparatus for Freeze-Drying The Drying Chamber . . . . . . The Ice Condenser . . . . . . . The Refrigeration Unit . . . . . The Vacuum Pump . . . . . . .
. . . . .
101 101 101 101 102
Cellular Labeling with 99mTc Chelates: Relevance of In Vitro and In Vivo Viability Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
103
8.1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
103
8.2
Red Blood Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
103
8.3
Platelets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
108
8.4
White Blood Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
114
8.5
Stem Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
118
8.6
Conclusions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
118
E. Chiotellis
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
. . . . .
H. Sinzinger, M. Rodrigues
9
99m
Tc Pharmaceuticals . . . . . . . . . . . . . .
123
9.1 9.1.1
Determination of Chemical Purity . . . . . . . . . . . . . . . . . . . . . . Thin-Layer Chromatography . . . . . . . . . . . . . . . . . . . . . . . . . .
123 123
9.1.2
Column Chromatography . . . . . . . . . . . . . . . . . . . . . . . . . . . .
136
9.1.3
Electrophoresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
143
9.2
Determination of Tin(II) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
144
9.3
Sterility Testing of Radiopharmaceuticals . . . . . . . . . . . . . . . . .
146
9.3.1 9.3.2 9.3.3
Problems in Applying European Pharmacopeia Test to Radiopharmaceuticals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Recommendations for Sterility Testing of Radiopharmaceuticals . . Frequency of Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
146 147 148
9.4
Pyrogen Testing of Radiopharmaceuticals . . . . . . . . . . . . . . . .
148
9.4.1
Recommendations for Endotoxin Determinations of Radiopharmaceuticals . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
149
Quality Control Methods of
C. Decristoforo, I. Zolle F. Rakis, J. Imre J. Imre
F. Rakis
S. R. Hesslewood
S. R. Hesslewood
XVI
Contents
10 Other Tc Isotopes: 94mTc as a Potential Substitute in Positron Emission Tomography Investigations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Z. Kovcs
151
10.1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
151
10.2
Methods of Production . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
151
10.3
Methods of Separation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
152
11 The Rules Governing Medicinal Products for Human Use in the European Union . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
155
11.1
European Economic Community Directives and Regulations . . . .
155
11.1.1 11.1.2 11.1.3 11.1.4 11.1.5 11.1.6 11.1.7
Application for Marketing Authorization Industrial Production . . . . . . . . . . . . . Marketing Authorization . . . . . . . . . . . Sales and Distribution . . . . . . . . . . . . Pharmacovigilance . . . . . . . . . . . . . . Other Aspects . . . . . . . . . . . . . . . . . SPC for Radiopharmaceutical Products .
. . . . . . .
157 158 158 159 159 159 160
11.2
The European Pharmacopeia . . . . . . . . . . . . . . . . . . . . . . . . .
161
11.2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.2.2 Monographs on Radiopharmaceuticals in the European Pharmacopeia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.2.3 Elaboration of New European Pharmacopeia Monographs on Radiopharmaceutical Preparations . . . . . . . . . . . . . . . . . . . .
161
11.3
A. Verbruggen, I. Zolle
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
A. Verbruggen
162 163
European Union Legislation Concerning New Drug Development . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
165
11.3.1 European Commission Directives and Guidelines . . . . . . . . . . . . 11.3.2 Clinical Trials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.3.3 CTA Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
165 166 166
A. Verbruggen
Part 2 12 Monographs of
Tc Pharmaceuticals . . . . . . . . . . . . . . . . . . . . . .
173
Tc-Pertechnetate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
173
Tc-Labeled Human Serum Albumin . . . . . . . . . . . . . . . . . Tc-Albumin (HSA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
181 181
Tc-Albumin Macroaggregates (MAA) . . . . . . . . . . . . . . . . .
187
Tc-Albumin Microspheres (HAM) . . . . . . . . . . . . . . . . . . . .
194
12.1
99m
12.2 12.2.1
99m
12.2.2
99m
12.2.3
99m
I. Zolle and P. O. Bremer 99m
I. Zolle and Gy. Jnoki I. Zolle and Gy. Jnoki 99m
I. Zolle
Contents
12.3 12.3.1
99m
12.3.1.1
99m
12.3.1.2 12.3.1.3 12.3.1.4 12.3.2 12.3.2.1 12.3.2.2
Tc-Labeled Colloids . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tc-Labeled Microcolloids . . . . . . . . . . . . . . . . . . . . . . . . .
201 201
Tc-Tin Colloid (Size Range: 0.2±0.8 lm) . . . . . . . . . . . . . . . .
201
Tc-Rhenium Sulfide Colloid . . . . . . . . . . . . . . . . . . . . . . . .
207
Tc-Albumin Microcolloid . . . . . . . . . . . . . . . . . . . . . . . . .
213
Tc-Albumin Millimicrospheres
.....................
218
Tc-Labeled Nanocolloids . . . . . . . . . . . . . . . . . . . . . . . . . Tc-Rhenium Sulfide Nanocolloid . . . . . . . . . . . . . . . . . . . .
224 224
Tc-Albumin Nanocolloid . . . . . . . . . . . . . . . . . . . . . . . . . .
230
99m
I. Zolle I. Zolle 99m
I. Zolle 99m
I. Zolle 99m
I. Zolle 99m 99m
I. Zolle
99m
I. Zolle
12.4 12.4.1
99m
12.4.2
99m
99m
Tc-Labeled Myocardial Perfusion Agents . . . . . . . . . . . . . . Tc-MIBI (Methoxyisobutyl Isonitrile) . . . . . . . . . . . . . . . . . .
237 237
Tc-Tetrofosmin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
245
F. Rakis and I. Zolle J. Imre and I. Zolle
12.5 12.5.1
99m
12.5.2
99m
99m
Tc-Labeled Brain Perfusion Agents . . . . . . . . . . . . . . . . . . Tc-HMPAO (Hexamethylpropylene Amine Oxime) . . . . . . . . .
251 251
Tc-ECD (Ethyl Cysteinate Dimer) . . . . . . . . . . . . . . . . . . . .
260
F. Rakis and I. Zolle J. Imre and I. Zolle
12.6
99m
12.7 12.7.1
99m
12.7.2
99m
Tc-Labeled Leukocytes . . . . . . . . . . . . . . . . . . . . . . . . . .
266
Tc-Labeled Bone Imaging Agents . . . . . . . . . . . . . . . . . . . Tc-Pyrophosphate (PYP) . . . . . . . . . . . . . . . . . . . . . . . . . .
271 271
Tc-Diphosphonates . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
280
I. Zolle and Gy. Jnoki 99m
S. Kladnik and I. Zolle
I. Zolle and S. Kladnik
12.8 12.8.1
99m
12.8.2
99m
12.8.3 12.8.4
99m
Tc-Labeled Renal Imaging Agents . . . . . . . . . . . . . . . . . . Tc-DMSA (Dimercaptosuccinic Acid) . . . . . . . . . . . . . . . . . .
291 291
Tc-DPTA (Diethylenetriaminepentaacetate) . . . . . . . . . . . . .
297
Tc-EC (Ethylene Dicysteine) . . . . . . . . . . . . . . . . . . . . . . . .
303
Tc-MAG3 (Mercaptoacetyltriglycine) . . . . . . . . . . . . . . . . . .
308
J. Kærnyei and I. Zolle J. Kærnyei and I. Zolle 99m
J. Kærnyei 99m
F. Rakis and I. Zolle
XVII
XVIII
Contents
12.9 12.9.1
99m
12.10 12.10.1
99m
12.11 12.11.1
99m
12.11.2
99m
99m
Tc-Labeled Hepatobiliary Agents . . . . . . . . . . . . . . . . . . . Tc-IDA (Iminodiacetic Acid) Derivatives . . . . . . . . . . . . . . . .
I. Zolle and A. G. Bratouss 99m
Tc-Labeled Peptides . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tc-Depreotide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I. Zolle 99m
315 315 322 322
Tc-Labeled Monoclonal Antibodies . . . . . . . . . . . . . . . . . . Tc-Arcitumomab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
328 328
Tc-Sulesomab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
333
F. Rakis F. Rakis
Appendix 1 Table A1, Administration of Radioactive Substances Advisory Committee (ARSAC): radiation doses for children . . . . . . . . . . . . . . . . . . 339 Table A2, European Association of Nuclear Medicine (EANM): radiation doses for children (issued by the Pediatric Task Group of the EANM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340 Recommended Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340 Appendix 2 Scope of COST B3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
343
List of Contributors Andreas G. Bratouss Nuklearmedizinische Klinik Klinikum Buch Helios Kliniken Berlin Wiltbergstraûe 50 13125 Berlin, Germany
Gyæzæ A. Jnoki Department of Applied Radioisotopes Frederic Joliot-Curie National Research Institute of Radiobiology and Radiohygiene 1221 Budapest, Hungary
Per Oscar Bremer Radioformulation Development GE Healthcare Instituttveien 18 PO Box 65 2027 Kjeller, Norway
Silvester Kladnik Department of Nuclear Medicine University Medical Centre Ljubljana 1525 Ljubljana, Slovenia
Trygve Bringhammar Medical Products Agency Radiopharmaceuticals 75103 Uppsala, Sweden
Zoltn Kovcs Radiochemistry Group Institute of Nuclear Research Hungarian Academy of Sciences 4001 Debrecen, DOB 51, Hungary
Efstratios Chiotellis Dept. of Pharmaceutical Chemistry School of Pharmacy Aristotelian University of Thessaloniki G-54124 Thessaloniki, Greece
JÕzsef Kærnyei Research and Development Radiopharmaceutical Business Line Institute of Isotopes Co., Ltd. Konkoly Thege M. Street, 29±33 1121 Budapest, Hungary
Clemens Decristoforo Medical Department of Nuclear Medicine Medical University Innsbruck Anichstraûe 35 6020 Innsbruck, Austria
Jens-Uwe Kçnstler Research Centre Rossendorf Institute of Radiopharmacy PF 510 119 01314 Dresden, Germany
Stuart R. Hesslewood Department of Physics and Nuclear Medicine City Hospital NHS Trust Birmingham B18 7QH United Kingdom
Jesus Mallol Escobar Universidad de La Laguna, Tenerife Schering Espaµa, SA 28045 Madrid, Spain
Jnos Imre National Institute of Pharmacy Radiochemistry Section 1051 Budapest, Hungary
Ulderico Mazzi Professor of Pharmaceutical Sciences University of Padova Via F. Marzolo, 5 35131 Padova, Italy
XX
List of Contributors
Hans-Juergen Pietzsch Research Centre Rossendorf Institute of Radiopharmacy PF 510 119 01314 Dresden, Germany Ferenc Rakis Drug Quality Department National Institute of Pharmacy 1051 Budapest, Hungary Margardia Rodrigues Department of Nuclear Medicine Medical University Vienna 1090 Vienna, Austria Roger Schibli Center for Radiopharmaceutical Science, OIPA Paul Scherrer Institute ETH Zçrich 5232 Villigen PSI, Switzerland
Helmut Sinzinger Department of Nuclear Medicine Medical University Vienna 1090 Vienna, Austria Hartmut Spies Research Centre Rossendorf Institute of Radiopharmacy PF 510119 01314 Dresden, Germany Alfons Verbruggen Professor of Radiopharmaceutical Chemistry Onderwijs en Navorsing 2, Box 821 Herestraat 49 3000 Leuven, Belgium Ilse Zolle Department of Medicinal/ Pharmaceutical Chemistry University of Vienna Althanstraûe 14 1090 Vienna, Austria
Part I
Chapter 1
Drug Safety
1
I. Zolle The unification of European states has made it necessary to harmonize legislation governing medicinal products in the member states. Guidelines have been published on the detailed requirements for verification of quality, safety, and efficacy, and on good manufacturing practice (GMP) for the manufacture of medicinal products for human use, as laid down in the Community Directives and authorized by the European Agency for the Evaluation of Medicinal Products in London (EMEA). Directive 89/343/EEC is extending the scope of pharmaceutical directives to radiopharmaceuticals. Account must be taken of the relevant CPMP guidelines (Committee of Proprietary Medicinal Products) and of guidelines developed by the International Conference on Harmonization (ICH). The harmonization process affected all levels of drug handling, and thus has put strict requirements on the preparation and use of radioactive drugs in hospital facilities. The transition period may be characterized as a major communicative effort between European institutions in order to exchange scientific knowledge and gain practical experience for the implementation of GMP standards for the preparation of 99mTc pharmaceuticals (Directive 91/356/EEC).
1.1 Quality Control and COST The Austrian Ministry of Science and Research recognized the importance of quality standards for radiopharmaceuticals, and gave full support for cooperation between the Department of Nuclear Medicine at the Medical University in Vienna (AKH-Wien) and the National Institute of Pharmacy in Budapest. This bilateral cooperation between Austria and Hungary during 1991±1994 formed the basis for initiating an European cooperation (COST). COST Action B3 (1992±1997) was devoted to the development of new radiotracers for nuclear medicine application and methods of quality assurance. National institutions of sixteen European states participated in five Working Groups (WG). Working Group 1 was concerned with the standardization of methods for labeling and quality control: · Working Group 1(a) Quality control of 99mTc pharmaceuticals, Coordinator F. Rakias (Hungary) · Working Group 1(b) Standardization of radioiodination reactions, Coordinator J. Mertens (Belgium) The scientific goal of Working Group 1(a) has been the development and updating of quality control methods to assure safety of 99mTc pharmaceuticals for parenteral application in nuclear medicine. Scientific institutions in 12 European countries have contributed their experience and results for comparison of the available methods. The Eu-
4
1.4 Quality Control of Kit Products
ropean cooperation COST B3 offered the framework for the exchange of young scientists in the field and mobilized national activities; without the spirit of a common goal, this task would not have been accomplished. The best analytical methods to demonstrate radiochemical purity and factors affecting product stability and safe application in patients have been described for each 99mTc pharmaceutical in monographs presented in Part 2.
1.2 Quality Standards Identity and purity, stability, and sterility and apyrogenicity. The identity and purity of radiopharmaceuticals is verified by determining the radionuclidic and radiochemical purity. Stability concerns the radioactive label, which is related to radiochemical purity at a certain time after preparation. Since 99mTc pharmaceuticals are formulated as sterile, pyrogen-free solutions, the safety requirements of drugs for parenteral use do apply. Safe handling of the radionuclide is equally important and must comply with Euratom Directives, regulated by national law for radiation protection, which also concerns the application of radionuclides in adults and in children for diagnostic procedures.
1.3 Quality Assurance An inherent difference between radiopharmaceuticals and nonradioactive medicinal products is their radioactive decay. In fact, 99mTc pharmaceuticals have an expiration of hours. After expiration, the radiopharmaceutical should no longer be used because its quality has changed. Radioactive decay puts stringent requirements on the production and use of radiopharmaceuticals. Short-lived radiopharmaceuticals have to be manufactured, quality-tested, and dispensed within a short time, adding constraint on safety procedures. In order to comply with the strict requirements of GMP, special methods for synthesis and ªin processº quality control have been developed, assuring high quality of radiopharmaceuticals, without actually testing sterility and apyrogenicity before dispensing the labeled product.
1.4 Quality Control of Kit Products In the case of 99mTc pharmaceuticals, chemistry and safety have been compounded into kits, which have overcome the limitations set by radioactive decay and the risk of bacterial contamination. Kits are manufactured in advance in accordance with GMP requirements for the manufacture of sterile medicinal products, have a long shelf life, and facilitate ad hoc labeling whenever there is a demand in nuclear medicine. Kits provide safety and ease of preparation of highly complex molecules by using aseptic techniques for labeling. Consequently, quality control requirements for kit preparations rely merely on testing the radiochemical purity of a 99mTc pharmaceutical to demonstrate stability in compliance with the purity requirements stated in the pharmacopeia.
Chapter 1 Drug Safety
Sterile labeling units (kits) and closed systems offer flexibility for new synthetic concepts with radionuclides and play a major role in the production of short-lived radiopharmaceuticals. High labeling efficiency, short synthesis time, and high safety standards are excellent characteristics for routine production on site, where radiopharmaceuticals are administered.
1.5 European Economic Community Directives and Regulations Council Directive 65/65/EEC Council Directive 75/318/EEC Council Directive 75/319/EEC Council Directive 89/342/EEC Council Directive 89/343/EEC Council Directive 91/356/EEC Council Regulation (EEC) No 2309/93 Euratom Directives 84/466 and 84/467
(26 January 1965) (20 May 1975) (20 May 1975) (3 May 1989) (3 May 1989, radiopharmaceuticals) (13 June 1991, GMP) (22 July 1993, authorization of EMEA) (3 September 1984)
5
Chapter 2
Technetium in Medicine
2.1
2
99m
Technetium Chemistry
U. Mazzi Technetium is an artificial element obtained by the radioactive decay of molybdenum. Element 43, named technetium in 1947, had been discovered in 1937 by Carlo Perrier and Emilio Segr in a sample obtained from the Berkely Radiation Laboratory (now Lawrence Berkeley National Laboratory) in California (Perrier and Segr 1937, 1947). By bombarding a molybdenum strip with 8-MeV deuterons in a 37-in. cyclotron, a radioactive molybdenum species (half-life, 65 h) had been obtained which decayed by b-emission to a short-lived isotope (half-life, 6 h) with novel properties, identified as technetium-99m (Segr and Seaborg 1938). In 1965, Richards and his collaborators at Brookhaven National Laboratories (N.Y.) have introduced the 99Mo/99mTc generator for clinical application (Richards 1966). This radionuclide system made technetium-99m available for clinical research and has stimulated the development of the first labeled compounds, which had a considerable impact on radiochemistry and nuclear medicine (Andros et al. 1965; Harper et al. 1966; McAfee et al. 1964a, b; Stern et al. 1965, 1966). In the years to follow, diagnostic nuclear medicine procedures based on 99mTc pharmaceuticals increased to approximately 85%. The reasons for this rapid growth were the ideal nuclear properties of technetium-99m, its availability worldwide as a radionuclide generator system, and the development of new labeling techniques. Labeling procedures have been greatly facilitated by kit preparations (Eckelman et al. 1971). Sterile kits for labeling contain the chemical ingredients in lyophilized form are commercially available and used to prepare 99mTc pharmaceuticals shortly before application to the patient. Manipulation is minimal, since all that needs to be done is adding the 99mTc activity to the kit. In some cases, heating of the reaction mixture is performed to increase the labeling yield. 99m Tc pharmaceuticals are organ specific and available to delineate blood flow in organs such as the lung (embolism), heart (ischemia/infarction), and brain (perfusion defects); to evaluate the functional state of the thyroid, liver (phagocytic function), kidney, or the hepatobiliary system (acute cholecystitis); and to detect tumor and metastatic growth in bone structures and more specifically, somatostatin-expressing tumors. Accordingly, the demands on chemical structure and biological performance vary considerably and need a sophisticated approach to radiopharmaceutical design. Research on new molecules has been growing steadily, stimulated by the demand for new medical applications. However, the low concentration of carrier-free 99mTc (1 Ci *10±9 M) in most 99mTc pharmaceuticals poses difficulties when determining their chemistry. Therefore, structural characterization of new 99mTc complexes is preferably studied with isotope 99Tc, a long-lived b-emitter (T1/2 = 2.12 ´ 105 years), which is commercially available in macroscopic amounts. Analogous 99Tc complexes may be identified using standard analytical techniques such as mass spectrometry, nuclear magnetic resonance (NMR), x-ray crystallography, UV, and elemental analysis.
8
2.1
99m
Technetium Chemistry
2.1.1 Technetium Compounds and Their Structures The knowledge of the chemical properties of technetium has grown over the years, as indicated by review articles and books (Dewanjee 1990; Lever 1995; Nowotnik 1994; Peacock 1966; Schwochau 1983; Steigman and Eckelman 1992). Of particular interest are the Proceedings of the International Symposium on Technetium in Chemistry and Nuclear Medicine, presenting new developments in complex chemistry of technetium and rhenium, with state-of-the-art lectures, listed at the end of this chapter under ªFurther Readingº. The element technetium belongs to group VIIB of the periodic table, between manganese and rhenium. The atomic radius of technetium is similar to rhenium; thus, many similarities are found in the chemistry between the two elements. The electronic configuration of the neutral atom 43 is described by [Kr]4d65s1, indicating the 4d and 5s orbitals that contribute to several oxidation states. Technetium can exist in eight oxidation states, varying from (VII) to (-I). Considering carrier-free chemistry, the most stable states are (VII), (V), (IV), (III), (I), and 0. Most difficult to stabilize are states (VI), (II), and (-I) (Mazzi 1989). The highest oxidation state (VII) is occupied by a pertechnetate anion (TcO±4) (Fig. 2.1.1), which is eluted from the 99Mo/99mTc generator. The chemical reactivity of the pertechnetate anion is negligible; it does not bind directly to any ligand. Thus, for the production of 99mTc pharmaceuticals, reduction to lower oxidation states in the presence of a suitable ligand is a prerequisite for the synthesis of 99mTc-labeled molecules. During reduction, the ligand stabilizes the lower oxidation state, otherwise, colloidal TcO2 is formed in aqueous media (Lever 1995; Nowotnik 1994). An exception is technetium sulfide (Tc2S7), known as 99mTc-sulfur colloid (Stern et al. 1966). Scavenging molecules like phosphinimine (R3P = N-SiMe3) have been reported to incorporate TcO±4, producing organic molecules containing Tc(VII) (Katti et al. 1993; Singh et al. 1995). With the exception of 99mTc colloids, 99mTc pharmaceuticals used in nuclear medicine are metal complexes, prepared by reducing 99mTc-pertechnetate to a lower oxidation state. The so-called coordination complexes of technetium (central metal) are formed by means of bonds between technetium acting as Lewis acid, and atoms or functional groups, which act as Lewis bases (they donate electron pairs). Typical ligands for technetium complex formation may have one donor group (monodentate) such as amine, amide, thiol, phosphine, oxime, or isonitrile. With two donor groups, the complex is bidentate; when more than two donor groups from a single molecule bind to one Tc core, is it a chelate (Nowotnik 1994). The redox potential of TcO±4/TcO2 was found to be + 0.738 V, and that of TcO±4/Tc, 0.477 V (Mazzi 1989). In the presence of suitable ligands, the redox potentials of the TcO±4/Tc complex are dependent upon the stability of the complex itself. It depends on the ligand, in which oxidation state a complex will be stabilized. In presence of oxygen atoms Tc(VI) is not stable, it rather disproportionates to (IV) and (VII). However, if a Tc(VI) complex is very stable, no further reduction is possible. In any case, pertechne±
Fig. 2.1.1. Pertechnetate anion
Chapter 2 Technetium in Medicine
tate is a weak oxidant, certainly weaker than permanganate; in acid medium, it is reduced by weak reductants. In kits, SnCl2 is commonly used as reductant. In certain cases, excess ligand may also act as reductant. The pertechnetate anion, when reduced in the presence of ligands, usually does not release all the oxygen atoms, leading to complexes in which a TcO3+ or a TcO+2 core is identified. Complexes containing a TcO3+ core show an octahedral six-coordinated or a square pyramidal five-coordinated spatial configuration; complexes containing a TcO+2 core form octahedral six-coordinated complexes. In the presence of suitable ligands, other cores and complexes of lower oxidation states (IV, III, I) may be achieved (Jones and Davison 1982).
2.1.2 Technetium(V) complexes The majority of
99m
Tc pharmaceuticals contain technetium as Tc(V) (Table 2.1.1).
2.1.2.1 Tc-Gluconate Tc(gluconate) and Tc(glucoheptonate) have been the earliest products of Tc(V) used as radiotracers for renal imaging (De Kieviet 1981; Johannsen and Spies 1988). The compounds were shown to contain a Tc=O3+ core, but their structures are not completely defined, probably because of more than one stable species at carrier-added level (De Kieviet 1981). However, the x-ray structure of similar Tc complexes with similar ligands (Davison et al. 1987; DePamphilis et al. 1974; Fig. 2.1.2), indirectly supports the formulation as TcO(Glu)±2, even though the structure of TcO(Ox)(OxH)± demonstrates the possibility of another species with a Tc=O3+ core (Abrams et al. 1991).
Fig. 2.1.2. [TcO(cathecol)2]±
These compounds are easily obtained in high yields at no carrier-added level, and they are suitable precursors in the synthesis of new 99mTc complexes by ligand exchange (or transchelation) (Spies et al. 1980). Other polyhydroxy or hydroxyl acids have been under investigation, such as glycolate, glucarate, tartrate, or citrate, which have been used in transchelation procedures.
9
10
2.1
99m
Technetium Chemistry
Table 2.1.1. Chemical state of
99m
Tc-pharmaceuticals in clinical or preclinical use
Compound
Oxidation state core
Geometry
Coordinated number
Charge
Reference
Gluconate
Tc(V)O+3
Square pyramid
5
±1
Glucoheptonate DMSA
Tc(V)O+3
Square pyramid
5
±1
TcO+3 or Tc(III)
Octahedral
5
0 or ±1
Penicillamine
Tc(V)O+3
Octahedral
6
0
EDTA
Tc(V)O+3
Heptahedral
6
0
HMPAO (Ceretec) MRP20 (Neuroscint) DADS
Tc(V)O3+
Heptahedral
6
0
Johannsen and Spies 1988 De Kieviet 1981 Bandoli et al. 1984; Ikeda et al. 1977 Franklin et al. 1982 Davison and Jones 1982 Fair et al. 1984
Tc(V)O+3
Heptahedral
6
0
Tc(V)O+3
Square pyramid
5
0
DADT
Tc(V)O+3
Square pyramid
5
0
ECD (Neurolite) MAG (MAG3)
Tc(V)O+3
Square pyramid
5
0
Tc(V)O+3
Square pyramid
5
0
Tc(V)O+2
Octahedral
5
+1
Tc(V)N+2
Octahedral
5
0
EDTA
Tc(IV) or Tc(III)
Dimeric
7 or 6
0 or ±1
DTPA
Tc(IV) or Tc(III) Tc(IV)
Monomeric
?
±1(?)
Monomeric
?
0
Tc(III)
Octahedral
6
±1
Tc(III)
Octahedral
6
+1
Tc(III)
Octahedral
6
+1
Tc(III)
Octahedral
6
0
Tc(I)
Octahedral
6
+1
Tetrofosmin (Myoview) NOEt
MDP HIDA (Choletec) DMPE Q12 (Technecard) BATO (Cardiotec) MIBI (Cardiolite)
Morgan et al. 1990 Davison et al. 1980 Watson et al. 1987 Edwards et al. 1990 Nosco et al. 1989 Kelly et al. 1993 Pasqualini et al. 1994 Davison and Jones 1982; Burgi et al. 1981 Gorski and Koch 1970 Lisbon et al. 1980 Loberg and Fields 1978 Deutsch et al. 1981 Deutsch et al. 1987 Bandoli et al. 1982 Abrams et al. 1983
DMSA dimercaptosuccinic acid, EDTA ethylenediaminetetraacetic acid, HMPAO hexamethyl propyleneamine oxime, DADS N,N-bis(mercaptoacetyl)ethylenediamine, DADT diaminodithiol, ECD ethylcysteinate dimer, MAG3 mercaptoacetyltriglycine, NOEt Et(OEt)NCS2, DTPA diethylene triamine pentaacetate, MDP methylenediphosphonate, HIDA N-(2,6-dimethylphenylcarbamoylmethyl) iminodiacetic acid, DMPE 1,2-bis(dimethylphosphino) ethane, BATO boronic acid technetium oxime, MIBI methoxyisobutyl isocyanide
Chapter 2 Technetium in Medicine
2.1.2.2 Tc-Dimercaptosuccinic Acid Two different 99mTc-dimercaptosuccinic acid (DMSA) complexes are in clinical use, 99m Tc(III)-DMSA with high binding affinity for renal tubuli and 99mTc(V)-DMSA with tumor affinity. At acidic pH, at least four 99mTc-DMSA complexes have been identified in dependence of pH and stannous ion concentration (Ikeda et al. 1977 b). Formation of a 99m Tc(III)-DMSA complex is favored at pH 2.5, using an excess amount of stannous ion (Ikeda et al. 1976). This formulation is used for renal scintigraphy (Ikeda et al. 1977 a). The coordination characteristics of the 99mTc(III)-DMSA complex have not yet been established. At an elevated pH (pH 7.5±8.0), a 99Tc-DMSA complex was produced, which accumulated in the skeleton (Johannsen et al. 1979). Further studies performing ligand exchange with Tc(V)-gluconate (Spies et al. 1980) led to the identification of a pentavalent 99m Tc-DMSA complex with two DMSA molecules coordinated to a Tc(V)oxo core (Bandoli et al. 1984) (Fig. 2.1.3). Pentavalent 99mTc-DMSA has been evaluated as a soft tumor-imaging agent (Yokoyama et al. 1985).
Fig. 2.1.3. Meso-[TcO(dimercaptosuccinic acid)2]±
2.1.2.3 Tc-Penicillamine Figure 2.1.4 shows the structure of a 99Tc complex with two molecules of penicillamine, confirmed by x-ray crystallography (Franklin et al. 1982). Yet when reduction of 99mTcpertechnetate had been performed with SnCl2, a complex with a Tc(IV) oxidation state was reported (Yokoyama et al. 1979).
Fig. 2.1.4. [TcO(penicil)2]
11
12
2.1
99m
Technetium Chemistry
2.1.2.4 Tc-Ethylenediaminetetraacetic Acid and Tc-Diethylene Triamine Pentaacetate Ethylenediamine tetraacetic acid (EDTA) and diethylene triamine pentaacetate (DTPA) are strong coordinating ligands that are administered to reduce in vivo toxicity of heavy metals. Nevertheless, the coordination behavior of EDTA and DTPA ligands with respect to technetium is rather complicated (Steigman et al. 1975). 99 Tc-EDTA chemistry studies demonstrated at least two types of stable complexes, one containing a Tc(V)O+3 core in a hepta-coordinated environment (Davison and Jones 1982), and the other is a complicated dimer in which technetium can be present as Tc(IV) or as Tc(III) (Linder 1986; Noll et al. 1980; Seifert et al. 1982). The crystal structure of a Tc(IV) complex has been reported (Burgi et al. 1981). The exact structure of the 99mTc species was not yet found, mainly because at very low concentrations dimerization is very improbable, and in these solutions Tc(IV) or Tc(III) was detected. The participation of tin in the dimer formation cannot be excluded. In any case, the products pass rapidly through the kidneys. These facts underline the difficulty of defining the chemical species present in the injection solution. To date, no complex with DTPA has been characterized at the 99Tc level. Undoubtedly, the production of a monomeric species is expected when EDTA and DTPA are used as chelating moiety for monoclonal antibody labeling.
2.1.2.5 Tc-Hexamethyl Propyleneamine Oxime (CeretecTM) The structure of d,l-TcO (hexamethyl propyleneamine oxime [HMPAO]) is shown in Fig. 2.1.5.
Fig. 2.1.5. d,l-TcO-hexamethyl propyleneamine oxime (HMPAO)
HMPAO is coordinated to a TcO3+ core with four nitrogen atoms. Ring closure of the oxime functionalities by hydrogen bonding increases the stability of the lipophilic complex. 99m Tc-d,l-HMPAO was characterized at the 99Tc level (Fair et al. 1984; Jurisson et al. 1987) and is the first neutral 99mTc complex for brain perfusion imaging (Troutner et al. 1984). The structural configuration has considerable effect on cerebral extraction, the d,l isomers pass the blood±brain barrier (BBB) while the mesoform is excluded (Sharp et al. 1986).
Chapter 2 Technetium in Medicine
However, lipophilic d,l-HMPAO is easily transformed into a charged complex, which cannot pass the BBB. Once inside the brain, this ªsecondaryº complex is trapped and is released very slowly (Neirinckx et al. 1987). The 99mTc-HMPAO complex is also used for labeling leukocytes with technetium.
2.1.2.6 Tc-MRP20 MRP20 is one of a series of tetradentate ligands, which incorporate donor sets containing pyrrole, amine, imine, and ketone moieties. The complex is neutral and lipophilic, similar to HMPAO. The chemical structure (Fig 2.1.6.) shows a five coordinated Tc-oxo complex in which the TcO3+ core is surrounded in the horizontal plane by the triple deprotonated ligand (Morgan et al. 1990, 1991). Tc-MRP20 was under investigation as a brain perfusion agent.
Fig. 2.1.6. Tc-MRP20
2.1.2.7 Tc-N,N'-bis(mercaptoacetyl)ethylenediamine and Tc-Diaminodithiol Tc-N,N'-bis(mercaptoacetyl)ethylenediamine (DADS) was introduced as a chelate, based on amide nitrogen and thiolate donor groups (Davison et al. 1979 and 1981). Tetradentate diaminodithiol (DADT) ligands form very stable complexes with oxo-technetium; the introduction of two carbonyl oxygen groups resulted in an overall negative charge. Several DADS-derived 99mTc complexes have been evaluated as renal agents (Brenner et al. 1984; Fritzberg 1986) (Fig. 2.1.7).
Fig. 2.1.7. Tc-N,N'-bis(mercaptoacetyl)ethylenediamine (DADS)
Substitution of the ethylene bridge (center chelate ring) with a carboxylate group produced 99mTc-CO2DADS as two stereoisomers (Costello et al. 1983), with one isomer resembling the tubular agent iodohippurate. 99mTc-CO2DADS is an important link in the development of the tubular agent 99mTc-mercaptoacetyltriglycine (MAG3). Structural modification of the N2S2 ligand has produced several 99mTc-DADT complexes. An example of substitution of the amine nitrogen (aminoalkyl-DADT) is 99mTc-
13
14
2.1
99m
Technetium Chemistry
Fig. 2.1.8. TcO-N-ethylpiperidinyl-tetradentate diaminodithiol (NEP-DADT)
N-ethylpiperidinyl (NEP)-DADT (Epps et al. 1978). Functionalization of hexamethylDADT with a NEP side chain was shown to enhance brain accumulation of neutral, lipophilic 99mTc-syn-NEP-DADT (Lever et al. 1985) (Fig. 2.1.8). 99m Tc-NEP-DADT is an example of systematic derivatization to optimize the structure±biodistribution relationship.
2.1.2.8 Tc-Ethylcysteinate Dimer The ethylcysteinate dimer (ECD) belongs to the family of neutral, lipophilic tetradentate diaminedithiol ligands. The x-ray structure (Fig. 2.1.9) shows the functionalized ester dimer with a Tc(V)oxo core in a square pyramidal configuration (Watson et al. 1987). In fact, its high-performance liquid chromatography (HPLC) behavior is the same for the 99Tc and 99mTc-ECD complex (Edwards et al. 1990). The l,l stereoisomer can cross the BBB and is retained in the brain, presumably due to hydrolysis of the ester function (Leveille et al. 1989). If hydrolysis happens in blood before the molecule has crossed the BBB, the resulting dicarboxylate anion is rapidly excreted by the kidneys. No difference was observed with the monoester monoacid derivatives (Verbruggen et al. 1989 a).
Fig. 2.1.9. Tc(V)O-ECD (ethylcysteinate dimer)
2.1.2.9 Tc-Mercaptoacetyltriglycine Replacement of one thiolate donor group by a planar amide carrying a carboxylate anion avoids formation of stereoisomers, as observed with 99mTc-CO2DADS. MAG3 is a suitable ligand for producing 99mTcO-MAG3, a negatively charged complex (Fig. 2.1.10), structurally defined at carrier-added (CA) (Davison et al.1981) and no-carrier added (NCA) (Fritzberg et al. 1986; Verbruggen et al. 1989 b) levels.
Chapter 2 Technetium in Medicine
Fig. 2.1.10. Tc(V)O-mercaptoacetyltriglycine±, or Tc(V)O-MAG±3
Steric arrangement of the carboxylate group in syn position with respect to Tc=O is responsible for active tubular secretion (Coveney and Robbins 1987; Fritzberg et al. 1986). A series of positional isomers of 99mTc-CO2DADS were synthesized in order to produce MAG3 as a ligand with suitable biological properties in man (Fritzberg 1986).
2.1.2.10 Tc-Tetrofosmin (P53) Myoview is a TcO+2 complex, obtained by functional derivatization of 1,2-bis(dimethylphosphino)ethane (DMPE) (Kelly et al. 1993). The chemical structure of 99mTc-tetrofosmin shows four phosphorus atoms of the bidentate diphosphine ligands, arranged in a plane (Fig. 2.1.11). However, tetrofosmin contains four ethoxyethyl groups, which ensure a rapid clearance of activity from the liver. The cationic charge facilitates myocardial uptake.
Fig. 2.1.11. TcO2P+4 (P53)
Trans-octahedral configuration of the donor atoms has been confirmed by x-ray single crystal analysis of the 99Tc analog. The HPLC behavior is the same for the 99Tc and 99m Tc tetrofosmin complex (Kelly et al. 1993). Phosphine ligands are interesting coordinating groups because they stabilize complexes with technetium at several oxidation states (from V to I) (Deutsch et al. 1983). They may act as Lewis bases (soft groups stabilizing trans-TcO+2 core) in the highest technetium oxidation states, and as p-acceptor ligands in the lowest oxidation states in which technetium possesses high electron density. Other p-acceptor ligands are isonitriles, nitrosyl, and carbon monoxide. Typical DMPE complexes have been reported (Deutsch et al. 1981, 1983). [TcVO2(DMPE)2]+, [TcIIICl2(DMPE)2]+ (Fig. 2.1.12), and [TcIDMPE)3]+ were found to be present both at CA and NCA levels, depending on the reaction conditions (Bandoli et al. 1982). As a cationic species, [TcIIICl2(DMPE)2]+ showed myocardial uptake; however, it is species dependent, and there is considerable liver uptake (Deutsch et al. 1989).
15
16
2.1
99m
Technetium Chemistry
Fig. 2.1.12. Tc(III)Cl2(1,2-bis(dimethylphosphino)ethane)+2 , or [Tc(III)Cl2(DMPE)2]+
The chemistry of Tc(V) complexes offers many possibilities for the synthesis of coordination complexes. In fact, the availability of different central cores can be used to stabilize a considerable number of ligands with very different coordinating properties. The TcO3+, trans-TcO+2 and trans-XTcO+2 (X = halogenide, O, alcoholate, N groups, etc.) cores are stabilized by various ligands, and the existence of one or the other core is attributed to the arrangement of the coordinating atoms in the horizontal plane perpendicular to Tc=O. Soft atoms stabilize a TcO3+ core, while harder ones produce trans-XTcO+2 or trans-TcO+2 cores (Davison 1983). For example, a cationic trans-TcO2+ complex is produced with tetradentate cyclam (Zuckman et al. 1981). [Tc(V)O2(Cyclam)]+ (Fig. 2.1.13) was investigated as a transchelating compound rather than as a radiopharmaceutical because it has no useful biological properties.
Fig. 2.1.13. TcO2 (Cyclam)+
2.1.2.11 TcN(NOEt) and Heterocomplexes with Metal±Nitrogen Multiple Bond Nitrido Tc(V) complexes with a technetium±nitrogen triple bond were introduced by Baldas et al. (1978); structural verification of a stable TcN2+ core was also documented (Marchi et al. 1990). Some donors of nitrido nitrogen atom (N3±) to yield the Tc:N2+ group have been evaluated; N-methyl-S-methyl dithiocarbazate [H2NN(CH3)± C(=S)SCH3] in acidic solution was found to be the most efficient ligand (Marchi et al. 1990; Pasqualini et al. 1992). In the presence of Tc:N2+, a high variability of the chelating set was observed. In comparison with Tc=O3+ cores, softer coordinating atoms produce more stable complexes. Dithiocarbazate seems to produce prereduced intermediary Tc complexes containing a Tc:N core, which undergo facile substitution reactions with the final ligands. The neutral [TcN(Et(OEt)NCS2] complex, called TcN(NOEt), was studied as a myocardial agent, demonstrating different biological properties with respect to the monocationic species (Pasqualini et al. 1994). The 99Tc complex with an Et2NCS2 ligand was structurally defined (Bolzati et al. 2002) (Fig. 2.1.14), showing a square-pyramidal configuration with two dithiocarbamate groups bound in the equatorial plane and a Tc:N core; the same species is present at the NCA level.
Chapter 2 Technetium in Medicine
Fig 2.1.14.. The neutral [TcN(Et(OEt)NCS2], also called Tc-NOEt
2.1.3 Technetium(IV), (III), and (I) complexes Technetium is stabilized at low oxidation states by suitable ligands such as phosphines, isonitriles, carbon monoxide, and thiourea (Gorski and Koch 1970). Organometallic carbonyl (CO) complexes are interesting precursors for a new class of 99mTc(I) radiopharmaceuticals (Alberto et al. 2001; Schibli et al. 2000). As reported previously, EDTA (Burgi et al. 1981) (Fig. 2.1.15) and many other ligands with no p-accepting groups can produce Tc(IV) or Tc(III) stable complexes, because other parameters such as chelating effect and metal±metal bonds contribute to their stabilization. Usually six-coordinated complexes in an octahedral configuration are obtained, but some exceptions are possible. In addition, the complex charge may vary in dependence of the ligand charge, deprotonation of the coordinating group; however, very exceptionally is the net charge more than one, negative, or positive.
Fig. 2.1.15. Tc-ethylenediaminetetraacetic acid (EDTA)
2.1.3.1 Tc-Diphosphonates 99m
Tc-methylenediphosphonate (MDP) and polyphosphate complexes were studied as Tc complexes, but only one x-ray structure was obtained with the diphosphonate ligand (Subramanian et al. 1975). 99mTc-MDP is a polymeric species in which tin is incorporated (Libson et al. 1980) (Fig. 2.1.16). The figure shows primarily the configuration at the central technetium. Reduction of 99TcO±4 with NaBH4 in the presence of hydroxyethylene diphosphonate (HEDP) produced seven different components detected by HPLC. It was demonstrated that the different species differ in molecular weight, depending on the size of the polymers (Van den Brand et al. 1981). Chemical yield of various components depends on the total technetium concentration, the polymerization reaction following high-order kinetics. As a single component, 99mTc-MDP and 99mTc-HMDP localize independently in the inorganic bone matrix. In order to obtain reproducible clinical results, bone agents must be pre99
17
18
2.1
99m
Technetium Chemistry
Fig. 2.1.16. Tc-diphosphonate
pared using fresh eluates obtained from a 99Mo/99mTc generator that is eluted regularly. 99m Tc diphosphonates show high skeletal uptake and are used for bone scintigraphy.
2.1.3.2 Tc-N-(2,6-dimethylphenylcarbamoylmethyl) iminodiacetic acid N-(2,6-dimethylphenylcarbamoylmethyl)iminodiacetic acid (HIDA) and several ether derivatives have been evaluated as ligands for complexation, producing 99mTc complexes suitable as hepatobiliary agents. 99mTc-IDA complexes have a negative charge (Loberg and Fields 1978). Two molecules of ligand are coordinated to one Tc(III)-core (Nunn et al. 1983) (Fig. 2.1.17).
Fig. 2.1.17. Tc-N-(2,6-dimethylphenylcarbamoylmethyl)iminodiacetic acid)2 ± (HIDA)
2.1.3.3 Tc-Q12 Complexes of the Q series are defined by their structure belonging to the [TcIIIP2L]+ complexes, with polydentate Schiff bases stabilized at the +3 oxidation state by a tertiary phosphine ligand (Deutsch et al. 1987). In fact, 99Tc(V)OCl-l-oxo complexes are easily reduced by a two-electron process to Tc(III). The final Tc(III) compound (Fig. 2.1.18) has an octahedral configuration with the two trans phosphines on the apexes and the tetradentate Schiff base on the equatorial plane (Jurisson et al. 1984). Tc-Q12 has a positive charge, the two hydroxyl groups being deprotonated. The 99Tc complex has been prepared in two steps, with an intermediate Tc(V)-oxo complex (Abrams et al. 1982). These complexes are well modified in the backbone, without decreasing the complex stability. Q12 is the best derivative in the series (Deutsch et al. 1987); however, none of these ligands has been used as a myocardial perfusion agent.
Chapter 2 Technetium in Medicine
Fig. 2.1.18. Tc(Q12). L Equatorial tetracoordinate ligand
2.1.3.4 Tc-Boronic Adducts of Technetium Oximes Dioxime type ligands can be considered as Schiff base bischelates (Deutsch et al. 1978; Bandoli et al. 1986). The first complexes with oxime ligands were described as monocapped Tc(dioxime)3(lOH)SnCl3 (dioxime = dimethylglyoxime) complexes (Treher et al. 1989). The boronic adducts of technetium oximes ± (BATOs) (Fig. 2.1.19) ± were well characterized, and some could be used both as myocardial and cerebral perfusion agents. The complexes are neutral; technetium is coordinated to three N-bonded dioxime molecules and to one Cl or Br atom in an axial position (seven covalent bonds). The three bidentate dioxime groups are joined through covalent B±O bonds to a tetrahedral boron cap derived from an alkyl boronic acid derivative. The six ligating nitrogen atoms form a monocapped distorted trigonal prism. It can be characterized by the geometry of the triangles of nitrogen or oxygen at the capped and uncapped ends of the complex. Different oximes can be used, but the major structural modifications of the complex are achieved at the boronic side chain (R1). One BATO-derived radiopharmaceutical, 99mTc-teboroxime (Cardiotec), has been available in the United States.
Fig. 2.1.19. Tc-boronic adducts of technetium oxime (BATO)
19
20
2.1
99m
Technetium Chemistry
2.1.3.5 Tc-Methoxyisobutyl Isocyanide Isonitriles, like carbon monoxide or phosphines, are ligands with high reducing properties together with a high capability of stabilizing low oxidation states. Tertiary butyl isonitrile (TBI) was the first ligand evaluated as a myocardial imaging agent (Holman et al. 1984). The positively charged Tc(I) complex showed high uptake in myocytes; however, clearance from the liver was slow. Introducing the 2-methoxy-derivative had a positive effect on the biodistribution, since the ether is metabolized and cleared faster. Structural characterization of Tc(I) complexes was performed identifying 99mTc sestamibi as a complex with six monodentate methoxyisobutyl isocyanide (MIBI) ligands attached symmetrically to a central Tc(I) atom (Abrams et al. 1983; Jones et al. 1985; Fig. 2.1.20).
Fig. 2.1.20. Tc-sestamibi. R = 2-methoxyisobutyl
Cationic Tc(I)-hexakis(2-methoxy-isobutyl-isonitrile) tetrafluroroborate is labeled by reacting tetrakis(2-methoxy-isobutyl-isonitrile)-copper(I) tetrafluroroborate adduct with 99m Tc-pertechnetate, using the kit formulation. Heating the reaction vial in a boiling water bath further facilitates formation of 99mTc(I) sestamibi. Clinical studies showed high myocardial extraction of 99mTc sestamibi and fast background clearance (Wackers et al 1989). Redistribution of the lipophilic complex is blocked by intracellular binding.
2.1.4
99m
Tc Labeling
99m
Tc chemistry is primarily the chemistry of anionic pertechnetate. This 99mTc species is eluted from the 99Mo/99mTc generator with high specific activity as an isotonic solution. Accordingly, 99mTc chemistry is aqueous solution chemistry in saline suitable to be injected intravenously. Also, 99mTc chemistry is an NCA chemistry because 99mTc activity is present in the radiopharmaceutical kit at 10±8 to 10±9 M. Direct labeling. Generally, direct labeling is performed by adding 99mTc eluate in a suitable volume to a sterile kit. The kit contains all chemical components, including a reducing agent. The labeling reaction requires reduction of pertechnetate, which is reacting with the ligand forming the labeled product in high yield (>90%).
Chapter 2 Technetium in Medicine
Exchange labeling. In a few exceptions, an intermediate ligand complex is formed (MAG3) that is stabilized by ligand exchange during heating. In the case of MIBI, the kit contains a preformed copper(I) complex, a so-called adduct, which facilitates formation of hexacoordinated 99mTc(I)-MIBI. Effect of formulation. Kits contain very low amounts of stannous ion for reduction of 99m Tc-pertechnetate; nevertheless, SnCl2 is usually in high excess. There are several reasons for using stannous salt in excess. Stannous salts are spontaneously oxidized in air. Also, oxidant species in the eluate may have been formed by radiolysis; the amount of Sn(II) available in solution is very low with respect to the total amount of lyophilized SnCl2. In order to assure validity of kits beyond the expiration date, an excess of SnCl2 is used in the kit formulation. On the other hand, there are cases in which the amount of reductant must be strictly controlled. This is indicated when more than one oxidation state is favored with a certain ligand, or when hydrolysis products interfere with complex stability. This precaution is possible with Sn(II) complexes (Sn-tartrate, Sn-gluconate, Sn-citrate, SnEDTA, etc.), which release small amounts of stannous ion into solution. In addition, another reducing agent, including the ligand itself, might be considered. Formation of colloidal TcO2 is avoided in the presence of ligand, which competes for the reduced technetium species, producing the labeled 99mTc pharmaceutical. In the absence of ligand, a mixture of hydrolized, insoluble 99mTc species, TcO2 ´ nH2O, is formed. To increase the rate of coordination, a high amount of the ligand is generally used. The kinetic mechanism of reduction-substitution is rather complicated, and sometimes it depends on the concentration of carrier 99mTcO±4. This is observed when 99 Tc carrier in the eluate is increased to CA level. Kit components. Kit composition is optimized to ensure that the unique 99mTc-labeled complex is obtained in high yield. Several factors influence the reduction/coordination process; these are primarily the nature and the amounts of reductant and ligand, pH, and temperature. Generally, the rate of complex formation is a good indicator of complex stability, which is essential to avoid increased background activity in vivo. In order to provide a suitable pH environment for the formation of a specific 99mTc complex, buffers are important components in kit formulations. Additives include antioxidants, catalysts, accelerators, solubilizing agents, and fillers (Nowotnik 1994). Antioxidants are added to the formulation in order to increase the stability of the radiopharmaceutical. Antioxidants for 99mTc complexes that have been used are ascorbic acid (Tofe and Francis 1976), gentisic acid (Tofe et al. 1980), and p-aminobenzoic acid (Rimmer 1982). A catalyst might be a ligand, which rapidly forms an intermediary coordination complex such as gluconate, DTPA, and citrate (Davison 1983). Ligand exchange is applied when complex formation with a certain ligand is slow relative to formation of reduced, hydrolized technetium, resulting in a poor radiochemical yield. Accelerators increase the radiochemical yield and rate of complex formation (Tweedle 1983). Surfactants might be required to solubilize lipophilic 99mTc complexes (MIBI) (Bergstein and Subramanyam 1986) and particulate preparations (macroaggregated albumin, microspheres).
21
22
2.1
99m
Technetium Chemistry
Solubility of the product in aqueous solution is indispensable. Equally important is the dissolution of the lyophilized kit contents when 99mTc eluate is added, in order to assure proper chemistry during the vitally important first few seconds of reconstitution. Inert fillers are added in order to achieve rapid solubilization of the vial contents through the control of particle size during the lyophilization process. The size of the lyophilizate plug and particle size are controlled by the freeze-dry cycle in kit production. Sodium chloride is added to d,l-HMPAO kits and mannitol to MIBI kits. Many variables in kit formulation have to be explored during the developmental phase of a new product in addition to the documentation of compatibility with different generator eluates and the shelf-life of the kit.
References Abrams MJ, Davison A, Brodack JW, Jones AG, Faggiani R, Lock CJ (1982) The preparation of technetium(III) compounds in aqueous media. J Labeled Comp Radiopharm 14:1596±1597 Abrams MJ, Davison A, Jones AG, Costello CE, Pang H (1983) Synthesis and characterization of hexakis(alkylisocyanide) and hexakis(arylisocyanide) complexes of technetium(I). Inorg Chem 22:2798±2800 Abrams MJ, Larsen S, Zubieta J (1991) Investigations of the technetium hydrazido core ± synthesis and structural characterization of [(N-C4H9)4N][Tc2(NNPH2)2(C6Cl4O2)4].CH2Cl2´2CH3OH, a Tc(V)/Tc(IV) catecholate complex with the hydrazido ligands adopting the unusual eta-1 bridging mode. Inorg Chem 30:2031±2035 Alberto R, Ortner K, Wheatley N, Schibli R, Schubiger PA (2001) Synthesis and properties of boranocarbonates: a convenient in situ CO source for the aqueous preparation of [99mTc(OH2)3(CO)3]+. J Am Chem Soc 123:3135±3136 Andros G, Harper PV, Lathrop KA, McCardle RJ (1965) Pertechnetate-99m localization in man with application to thyroid scanning and the study of thyroid physiology. J Clin Endocrinol Metab 25:1067±1076 Baldas J, Bonnyman J, Poier PM, William GA, Mackay MF (1981) Synthesis and structure of bis(diethyldithiocarbamato)nitrido technetium(V): a technetium-nitrogen triple bond. J Chem Soc Dalton Trans 9:1798±1801 Bandoli G, Mazzi U, Moresco A, Nicolini M, Refosco F, Tisato F (1986) Technetium complexes containing tridentate and bidentate Schiff base type ligands. In: Nicolini M, Bandoli G, Mazzi U (eds) Technetium in chemistry and nuclear medicine 2. Cortina International, Verona, Italy, pp 73±80 Bandoli G, Mazzi U, Roncari E, Deutsch E (1982) Crystal structures of technetium compounds. Coord Chem Rev 44:210 Bandoli G, Nicolini M, Mazzi U, Spies H, Muenze R (1984) Synthesis and X-ray crystal structure of tetraethylammonium bis[1,2-di(carbomethoxy)ethane-1,2-dithiolato]oxotechnetate(V). Transition Met Chem 9:127±129 Bergstein PL, Subramanyam V (1986) Ether isonitriles and radiolabeled complexes thereof. Eur. Patent Appl. EP 86117847.3 Bolzati C, Boschi A, Uccelli L, Tisato F, Refosco F, Cagnolini A, Duatti A, Pracash S, Bandoli G, Vittadini A (2002) Chemistry of the strong electrophilic metal fragment [99Tc(N)(PXP)]2+ (PXP diphosphine ligand). A novel tool for the selective labeling of small molecules. J Am Chem Soc 124:11468±11479 Brenner D, Davison A, Lister-James J, Jones AG (1984) Synthesis and characterization of a series of isomeric oxotechnetium(V) diamino dithiolates. Inorg Chem 23:3793±3797 Burgi HB, Anderegg G, Blauenstein P (1981) Preparation, characterisation, crystal and molecular structure of Na2[N(CH2COO)3Tc(IV)(m±O)2Tc(IV)(H2EDTA)´5H2O. Inorg Chem 20:3829±3834 Costello CE, Brodack JW, Jones AG, Davison A, Johnson DL, Kasina S, Fritzberg AR (1983) The investigation of radiopharmaceutical components by fast atom bombardment mass spectroscopy: the identification of Tc-HIDA and the epimers of Tc-CO2DADS. J Nucl Med 24:353±355 Coveney JR, Robbins MS (1987) Comparison of technetium-99m MAG3 Kit with HPLC-purified technetium-99m MAG3 and OIH in rats. J Nucl Med 28:1881±1887
Chapter 2 Technetium in Medicine Davison A (1983) The coordination chemistry of technetium In: Deutsch E, Nicolini M, Wagner HN Jr (eds) Technetium in chemistry and nuclear medicine 1. Cortina International, Verona, Italy, pp 3±14 Davison A, De Phamphilis BV, Jones AG, Franklin K, Lock CJL (1987) Synthesis and characterization of complexes containing the bis(1,2-thiolato)-oxotechnetium(V) core. Inorg Chim Acta 128:161±167 Davison A, Jones AG (1982) The chemistry of technetium(V). Int J Appl Radiat Isot 33: 875±881 Davison A, Jones AG, Orvig C, Sohn M. (1981) A new class of oxotechnetium(V) chelate complexes containing TcON2S2 core. Inorg Chem 20:1629±1632 Davison A, Sohn M, Orvig C, Jones AG, LaTegola MR (1979) A tetradentate ligand designed specifically to coordinate technetium. J Nucl Med 20:641 De Kieviet W (1981) Technetium radiopharmaceuticals: chemical characterization and tissue biodistribution of Tc-glucoheptonate using Tc-99m and carrier Tc-99. J Nucl Med 22:703±709 De Pamphilis BV, Jones AG, Davis MA (1974) Preparation and crystal structure of oxotechnetium bis(thiomercaptoacetate) and its relationship to radiopharmaceuticals labeled with 99mTc. J Am Chem Soc 78:5570±5571 Deutsch E, Elder RC, Laarge BA et al (1978) Structural characterization of a bridged technetium99-tin-dimethylglyoxime complex: implication for the technetium-99m-labeled radiopharmaceuticals prepared by tin(II) reduction of pertechnetate. Proc Natl Acad Sci USA 73:653±660 Deutsch E, Glavan KA, Sodd VJ et al (1981) Cationic Tc-99m complexes as potential myocardial imaging agents. J Nucl Med 22:897±907 Deutsch E, Ketring AR, Libson K, Vanderheyden J-L, Hirth WJ (1989) The Noah's ark experiment: species-dependent biodistributions of cationic 99mTc complexes. Int J Rad Appl Instrum 16:191±232 Deutsch E, Libson K, Jurisson S, Lindoy LF (1983) Technetium chemistry and technetium radiopharmaceuticals In: Lippard SJ (ed) Progress in inorganic chemistry. Wiley, New York, pp 75±139 Deutsch E, Vanderheyden J-L, Gerundini P, Libson K et al (1987) Development of non reducible technetium-99m(III) cations as myocardial perfusion imaging agents: initial experience in humans. J Nucl Med 28:1870±1880 Deutsch E, Vanderheyden JL, Gerundini P, Libson K, Hirth W, Colombo F, Savi A, Fazio F (1987) Development of nonreducible technetium-99m(III) cations as myocardial perfusion imaging agents: initial experience in humans. J Nucl Med 28:1870±1880 Dewanjee MK (1990) The chemistry of 99mTc-labeled radiopharmaceuticals. In: Seminars in nuclear medicine XX. Saunders, Philadelphia Eckelman WC, Meinken G, Richards P (1971) 99mTc-human serum albumin. J Nucl Med 12:707±710 Edwards D, Cheesman E¹ Watson M, Maheu L, Nguyen S, Dimitre L, Nason T, Watson A, Walovitch R et al (1990) Synthesis and characterization of technetium and rhenium complexes of N,N'-1,2-ethylenediylbis-l-cysteine. Neurolite and its metabolites. In: Nicolini M, Bandoli G, Mazzi U (eds) Technetium and rhenium in chemistry and nuclear medicine 3. Cortina International, Verona, Italy, p 433 Epps LA, Burns HD, Lever SZ et al (1978) Brain imaging agents: synthesis and characterization of (N-piperidinylethyl)hexamethyl diaminodithiolate oxo-technetium(V) complexes. Int J Appl Radiat Isot 38:661±664 Fair CK, Troutner DE, Schlemper EO, Murmann RK, Hoppe ML (1984) Oxo[3,3'-(1,3-propanediyldiimino)bis(3-methyl-2-butanone oximato)(3±)-N,N',N'',N''']-technetium(V), [TcO(C13H25N4O2)]. Acta Cryst C40:1544±1546 Franklin KJ, Lock HE, Lock CJL (1982) Preparation, spectroscopic properties and structure of 1-oxo2,3,6-(d-penicillaminato NSO)-4,5-(d-penicillaminato NS) technetium(V). Inorg Chem 21:1941 Fritzberg AR (1986) Advances in renal radiopharmaceuticals In: Fritzberg AR (ed) Radiopharmaceuticals: progress and clinical perspectives, vol. I. CRC Press, Boca Raton, pp 61±87 Fritzberg AR, Kasina S, Eshima D, Johnson DL (1986) Synthesis and biological evaluation of technetium-99m MAG3 as a Hippuran replacement. J Nucl Med 27:111±116 Gerson M, Deutsch E, Nishiyma H et al (1983) Myocardial perfusion imaging with 9mTc-DMPE in man. Eur J Nucl Med 8:371±374 Gorski B, Koch H (1970) Technetium complex formation with chelate-forming ligands. II. J Inorg Nucl Chem 32:3831±3836 Harper PV, Lathrop KA, Gottschalk A (1966) Pharmacodynamics of some technetium-99m preparations. In: Andrews GA, Knisely RM, Wagner HN Jr (eds) Radioactive pharmaceuticals. AEC symposium series conf 651111 1966, pp 335±357
23
24
2.1
99m
Technetium Chemistry
Holman BL, Jones AG, Lister-James J et al (1984) A new Tc-99m-labeled myocardial imaging agent, hexakis(t-butylisonitrile)technetium(I) (Tc-99mTBI). Initial experience in the human. J Nucl Med 25:13501355 Ikeda I, Inoue O, Kurata K. (1976) Chemical and biological studies on 99mTc-DMS-II: effect of Sn(II) on the formation of various Tc-DMS complexes. Int J Appl Radiat Isot 27:681±688 Ikeda I, Inoue O, Kurata K. (1977 a) Preparation of various Tc-99m dimercaptosuccinate complexes and their evaluation as radiotracers. J Nucl Med 18:1222±1229 Ikeda I, Inoue O, Kurata, K (1977 b) Chemical and biological studies on 99mTc-DMS-I: formation of complexes by four different methods. Int. J Nucl Med Biol 4:56±65 Johannsen B, Spies H (1988) Progress and problems in the chemistry of technetium-99m tracers. Isotopenpraxis 24:449±454 Johannsen B, Spies H, Syhre R (1979) Studies on complexation of 99mTc with dimercaptosuccinic acids with regard to organ specificity of 99mTc-radiopharmaceuticals. Eur J Nucl Med 4:148 Jones AG, Davison A (1982) The chemistry of technetium I, II, III, IV. Int Appl Radiat Isot 33:867± 874 Jones AG, Dionauge GF, Davison A et al (1985) Biological distribution and structure function relationship of hexakis isonitrile Tc(I) complexes (abstract). J Nucl Med All Sci 29:200 Jurisson S, Dancey K, McPartlin M, Tasker P, Deutsch E (1984) Synthesis, characterization, and electrochemical properties of technetium complexes containing both tetradentate Schiff base ligands and monodentate tertiary phopshine ligands: single crystal structure of trans-(N,N'-ethylene bis(acetylacetone-iminato)bis(triphenylphos- phine)-technetium(III)-hexafluoro-phosphate. Inorg Chem 23:4743±4744 Jurisson S, Schlemper EO, Troutner DE, Canning LR, Nowotnik DP, Neirinckx RD (1987) Synthesis, characterization and X-ray structural determination of Technetium(V)-oxo-tetradentate amine oxime complexes. Inorg Chem 25:3576±3582 Katti KV, Singh PR, Barnes CL, Katti KK, Kopicka K, Ketring AR, Volkert WA (1993) Organometallic phosphinimines as building blocks for potential new radiopharmaceuticals. Z Naturforsch 486:1381±1386 Kelly JD, Forster AM, Higley B, Archer CM, Booker FS, Canning LR, Chiu KW, Edwards B, Gill HK, McPartlin M, Nagle KR, Latham IA, Pickett RD, Storey AE, Webbon PM (1993) Technetium-99m-tetrofosmin as a new radiopharmaceutical for myocardial perfusion imaging. J Nucl Med 34:222±227 Leveille J, Demonceau G, De Roo M, Rigo P, Taillefer R, Morgan R, Kupranick D, Walovitch RC (1989) Characterization of technetium-99m-l,l-ECD for brain perfusion imaging, part 1. Pharmacology of technetium-99m ECD in nonhuman primates. J Nucl Med 30:1892 Lever SZ (1995) Technetium and rhenium compounds. In: Wagner HN Jr, Szabo S, Buchanan JW (eds) Principles of nuclear medicine, 2nd edn. Saunders, Philadelphia, pp 213±220 Lever SZ, Burns HD, Kervitsky TM, Goldfarb HW, Woo DV, Wong DF, Epps LA, Kramer AV, Wagner HN Jr (1985) Design, preparation and biodistribution of a technetium-99 diaminodithiol complex to assess regional cerebral blood flow. J Nucl Med 26:1287±1294 Libson K, Deutsch E, Barnett BL (1980) Structural characterisation of a Tc-99 diphosphonate complex. Implication for the chemistry of technetium-99m skeletal imaging agents. J Am Chem Soc 102:2476±2478 Linder KE (1986) Aminocarboxylate complex of technetium. PhD thesis, Massachusettes Institute of Technology, June Loberg MD, Fields AT (1978) Chemical structure of technetium-99m-labeled N-(2,6-dimethyl-phenylcarbamoylmethyl)-iminodiacetic acid (99mTc-HIDA). Int J Appl Radiat Isot 29:167±173 Marchi A, Garuti P, Duatti A et al (1990) Synthesis of technetium(V)-nitrido complexes with chelating amines: a novel class of monocationic, octahedral complexes containing the [Tc:N]2+ core. Crystal structures of [TcN(en)2Cl]+ (en = ethylenediamine) and [TcN(tad)Cl]+ (tad = 1,5,8,12-tetraazadodecane). Inorg Chem 29:2091±2096 Mazzi U (1989) The coordination chemistry of technetium in its intermediate oxidation states. Polyhedron 8:1983±1688 McAfee JG, Fueger GF, Baggish MS, Holzman GB, Zolle I (1964) 99mTc-labeled serum albumin for scintillation scanning of the placenta. J Nucl Med 5:936±946 McAfee JG, Fueger GF, Stern HS, Wagner HN Jr, Migita T (1964) 99mTc-pertechnetate for brain scanning. J Nucl Med 5:811±827 Morgan G, Deblaton M, Hussein W, Thornback J, Evrard G, Durant F, Stach J, Abram U, Abram S (1991) Rhenium(V) and technetium(V) complexes with N-(2(1H-pyrolmethyl))-N'-(4-pentene3-one-2)ethane-1,2-diaminate (C12H16N3O, MRP20) ± X-ray crystal-structures of H3MRP20 and TcO(MRP20). Inorg Chim Acta 190:257±264
Chapter 2 Technetium in Medicine Morgan GF, Abram U, Evrard G, Durant F, Deblaton M, Clemens P, Vandenbroeck P, Thornback JR (1990) Structural Characterization of the new brain imaging agent [99mTc][TcO(L)], H3L=N-4oxopentan-2-ylidene-N'-pyrrol-2-ylmethylen-ethane-1,2-diamine (MRP20). J Chem Soc Chem Comm 24:1772±1773 Neirinckx RD, Canning LR, Piper IM, Nowotnik DP, Pickett RD, Holmes RA, Volkert WA, Forster AM, Weisner PS, Mariott JA, Chaplin SB (1987) Technetium-99m d,l-HM-PAO: a new radiopharmaceutical for SPECT imaging of regional cerebral blood perfusion. J Nucl Med 28:191±202 Noll B, Seifert S, Muenze R (1980) New Tc(IV) compounds with nitrilo-triacetic acid. Radiochem Radioanal Lett 43:215±218 Nosco DL, Tofe AJ, Dunn TJ, Lyle LR et al (1989) New developments in radiopharmaceuticals at Mallinckrodt. In: Nicolini M, Bandoli G, Mazzi U (eds) Technetium and rhenium in chemistry and nuclear medicine 3. Cortina International, Verona, Italy, pp 381±392 Nowotnik DP (1994) Physico-chemical concepts in the preparation of radiopharmaceuticals In: Sampson CB (ed) Textbook of radiopharmacy: theory and practice, second enlarged edition. Gordon and Breach, Reading Nunn AD, Loberg MD, Conley RA (1983) A structure±distribution±relationship approach leading to the development of Tc-99m-mebrofenin: an improved cholescintigraphic agent. J Nucl Med 24:423±430 Nunn AD, Treher EN, Feld T (1986) Boronic acid adducts of technetium oxime complexes (BATOs), a new class of neutral complexes with myocardial imaging capabilities. J Nucl Med 27:893 Pasqualini R, Comazzi V, Bellande E, Duatti A, Marchi A (1992) A new efficient method for the preparation of 99mTc-radiopharmaceuticals containing the Tc:N multiple bond. Int J Appl Radiat Isot 43:1329±1333 Pasqualini R. Duatti A, Bellande E, Comazzi V, Brucato V et al (1994) Bis(dithiocarbamato)nitrido technetium-99m radiopharmaceuticals. A class of neutral myocardial imaging agents. J Nucl Med 35:334±341 Peacock RD (1966) The chemistry of technetium and rhenium. Elsevier, London Perrier C, Segr E (1937) Radioactive isotopes of element 43. Nature 140:193±194 Perrier C, Segr E (1947) Technetium: the element of atomic number 43. Nature 159:24 (Letter) Richards P (1966) Nuclide generators. In: Radioactive pharmaceuticals. USAEC symposium series, no. 6, (CONF-651111), Oak Ridge, Tenn., pp 155±163 Rimmer J (1982) Radiopharmaceutical composition based on technetium-99m and the reagent for making it. Eur Patent Appl EP 78,642 Schibli R, Labela R, Alberto R, Garcia-Garayoa E, Ortner K, Abram U, Schubiger PA (2000) Influence of the denticity of ligand systems on the in vitro and in vivo behavior of Tc-99m(I)-tricarbonyl complexes: a hint for the future functionalization of biomole-cules. Bioconjugate Chem 11:345±351 Schwochau K (1983) The present status of technetium chemistry. Radiochim Acta 32:139±152 Segr E, Seaborg GT (1938) Nuclear isomerism in element 43. Phys Rev 54:772 Seifert S, Noll B, Muenze R (1982) Studies of the complex formation of technetium(IV) with aminopolycarboxylic acids in aqueous solution. Int J Appl Radiat Isot 33:1391±1398 Sharp PF, Smith FW, Gemmel HG, Lyall D, Evans NTS, Gvozdanovic D, Davidson J, Tyrrell DA, Pickett RD, Neirinckx RD (1986) Technetium-99m HM-PAO stereoisomers as potential agents for imaging regional cerebral blood flow: human volunteer studies. J Nucl Med 27:171±177 Singh PR, Ketring AR, Volkert WA, Katti KV (1996) Potential of phosphinimines and phosphinimine-containing polymers as scavenging agents for the extraction of 99TcO±4 from aqueous media. In: Bandoli G, Mazzi U, Nicolini M, SG Editoriali (eds) Technetium and rhenium in chemistry and nuclear medicine 4. Padova, Italy, pp 239±242 Spies H, Johannsen B, Muenze R (1980) Kinetics investigations on the reaction of technetium(V) gluconate with meso-dimercaptosuccinic acid and meso-dimercapto-succinic acid dimethylester. Radiochemical Radioanal Lett 43:311±318 Steigman J, Eckelman WC (1992) The chemistry of technetium in medicine. National Academy Press, Washington, DC Steigman J, Meinken G, Richards P (1975) Reduction of pertechnetate-99 by stannous chloride. I. Stoichiometry of the reaction in hydrochloric acid, in a citrate buffer, and in a DTPA buffer. Int J Appl Radiat Isot 26:601±609 Stern HS, McAfee JG, Subramanian G (1966) Preparation, distribution and utilization of technetium-99m-sulfur colloid. J. Nucl Med 7:655±675 Stern HS, Zolle I, McAfee JG (1965) Preparation of 99mTc-labeled serum albumin. Int J Appl Radiat Isot l6:283±288
25
26
2.1
99m
Technetium Chemistry
Subramanian G, McAfee JG, Blair RG, Kallfelz FA, Thomas FD (1975) Technetium-99m-methylenediphosphonate ± a superior agent for skeletal imaging: comparison with other technetium complexes. J Nucl Med 16:744±755 Tofe AJ, Bevan JA, Fawzi MB, Francis MD, Silberstein EB, Alexander GA, Gunderson DE, Blair K (1980) Gentisic acid: a new stabilizer for low tin skeletal imaging agents: concise communication. J Nucl Med 21:366±370 Tofe AJ, Francis MD (1976) In vitro stabilization of a low tin bone imaging kit. J Nucl Med 16:414±422 Treher EN, Francesconi LC, Gougoutas JZ, Malley M, Nunn A (1989) Mono-capped tris dioxime complexes of technetium (III): synthesis and structural characterization of TCX (dioxime)3, B±R (X=Cl, Br; dioximedimethylglyoxime cyclohexanedioxime; R=CH3, C4H9). Inorg Chem 28:3411±3416 Troutner DE, Volkert WA, Hoffman TJ, Holmes RA (1984) A neutral lipophilic complex of 99mTc with a multidentate amine oxime. Int J Appl Radiat Isot 35:467±470 Tweedle MF (1983) Accelerators for forming cationic technetium complexes useful as diagnostic agents. Int. Patent Appl. PCT 83,02,615 Van den Brand JAGM, Das HA, Dekker B, De Ligny CL (1981) The gel chromatographic separation and identification of the Tc(Sn) HEDP complexes using the radiotracers 32P, 99mTc, 18Sn. Int J Appl Radiat Isot 32:637 Verbruggen A, Bormans G, Cleynhens B, Hoogmartens M, Vandecruys A, De Roo M (1989) Separation of the enantiomers of technetium-99m-MAG3 and their renal excretion in baboons and a volunteer. Nuklearmedizin 25:436±439 Verbruggen A, Bormans G, Van Nerom C, Cleynhens B, Crombez D, De Roo M (1989) Isolation of the mono-ester mono-acid derivatives of 99mTc-ECD and their biodistribution in mice. In: Nicolini M, Bandoli G, Mazzi U (eds) Technetium and rhenium in chemistry and nuclear medicine 3. Cortina International, Verona, Italy, pp 445±452 Wackers FJTh, Berman DS, Maddahi J, Watson DD, Beller GA, Strauss HW, Boucher CA, Picard M, Holman BL, Fridrich R, Inglese E, Delaloye B, Bischof-Delaloye A, Camin L, McKusick K (1989) Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging. J Nucl Med 30:301±311 Watson AD, Tulip TH, Roe DC (1987) The synthesis, characterization and multinuclear NMR studies of a technetium bisaminebisthiol complex: a new radiopharmaceutical precursor. In: Nicolini M, Bandoli G, Mazzi U (eds) Technetium in chemistry and nuclear medicine 2. Cortina International, Verona, Italy, 61±64 Yokoyama A, Hata N, Horiuchi K, Matsuda H, Saji H, Ohta H et al (1985) The design of a pentavalent 99mTc-dimercaptosuccinate complex as a tumor imaging agent. J Nucl Med 12:273±279 Yokoyama A, Horiuchi K, Hata N et al (1979) Technetium in technetium-99m radiopharmaceuticals. I. Tetravalent mononuclear technetium penicillamine complex. J Labeled Compd Radiopharm 16:80±81 Zuckman SA, Freeman GM, Troutner DE, Volkert WA, Holmes RA, Van Derveer DG, Barefield EK (1981) Preparation and X-ray structure of trans-dioxo(1,4,8,11-tetraazacyclotetradecane)technetium(V) perchlorate hydrate. Inorg Chem 20:2386±2389
Further Reading The following is a list of proceedings of the International Symposia on Technetium in Chemistry and Nuclear Medicine, Academia Cusanus, Bressanone (Italy). Deutsch E, Nicolini M, Wagner HN Jr, (1983) Technetium in chemistry and nuclear medicine 1. Cortina International, Verona, Italy Nicolini M, Bandoli G, Mazzi U (1986) Technetium in chemistry and nuclear medicine 2. Cortina International, Verona, Italy Nicolini M, Bandoli G, Mazzi U (1990) Technetium and rhenium in chemistry and nuclear medicine 3. Cortina International, Verona, Italy Nicolini M, Bandoli G, Mazzi U (1996) Technetium and rhenium in chemistry and nuclear medicine 4. SG Editoriali, Padova, Italy Nicolini M, Bandoli G, Mazzi U (1999) Technetium, rhenium and other metals in chemistry and nuclear medicine 5. SG Editoriali, Padova, Italy Nicolini M, Mazzi U (2002) Technetium, rhenium and other metals in chemistry and nuclear medicine 6. SG Editoriali, Padova, Italy
Chapter 2 Technetium in Medicine
2.2 The Technetium and Rhenium Tricarbonyl Core R. Schibli An aqua ion of technetium and rhenium, in analogy to, e.g. [Cu(OH2)6]2+, would be most convenient for radiolabeling procedures. However, such an aqua ion presumably does not exist or is very unstable. In an effort to solve this dilemma, Alberto and coworkers have designed and developed an organometallic semiaqua ion of the general formula [M(OH2)3(CO)3]+ (M Tc, Re), useful as precursor for the radiolabeling of biomolecules for diagnostic and therapeutic purposes (Alberto et al. 1995, 1998, 1999; Egli et al. 1997). The metal centers are in the oxidation state + 1 with a low-spin d6 electronic configuration. The high electron density is stabilized by three strong p-acceptors (CO) facially arranged. The precursors are water stable and water soluble, and the water molecules readily undergo ligand exchange, whereas the carbonyl ligands are substitution stable. The precursor [M(OH2)3(CO)3]+ is readily accessible directly from the corresponding sodium permetallate, Na[MO4] (Alberto et al. 1998; Schibli et al. 2002). The preparation comprises a six-electron reduction and concomitant coordination of three COs. The basis of Tc-99m kit formulation is disodium boronocarbonate (BC), Na2[H3BCO2], which serves as an in situ CO source and at the same time reduces the technetium center (Alberto et al. 2001). The kit is nowadays commercially available under the name Isolink (MallinckrodtTyco Med) for research purposes. BC is stable in aqueous solution and can be lyophilized. The precursor [99mTc(OH2)3(CO)3]+ can be synthesized in quantitative yield by adding generator eluate to the vial and subsequent heating to 100 8C for 20 min (Alberto et al. 2001). The preparation of the rhenium homologue [188Re(OH2)3(CO)3]+ deviated slightly from technetium, since rhenium is more difficult to reduce and reacts, in general, much slower. Therefore, H3B´NH3 is the reducing agent (eventually in combination with another polymer bound reducing agent), and the reaction must be carried out in the presence of H3PO4 at acidic pH (Park et al. 2006; Schibli et al. 2002). This formulation presently excludes an instant kit formulation for [188Re(OH2)3(CO)3]+. As mentioned above, [M(OH2)3(CO)3]+ can be considered as a normal aqua ion with only three available coordination sites. Substitution of the water molecules with almost any type of chelator (classic/nonclassic) forms kinetically stable coordination compounds. This holds true for mono-, bi-, and tridentate ligands, regardless of their hardness or softness. This behavior also represents the distinct feature of [M(OH2)3(CO)3]+ as compared with other technetium and rhenium metal centers, and is one of its major advantages for the labeling of molecules for imaging and therapeutic purposes. An enormous variety of mono-, bi-, and tridentate ligand systems comprising different donor atoms or groups have been developed and are still designed and optimized. Bifunctional chelating agents (BFCA) have been readily developed specifically for the purpose of functionalization of biomolecules and subsequent radiolabeling with the M(CO)3 core (Alberto et al. 2004; Alves et al. 2005; Banerjee et al. 2002, 2005 b; Correia et al. 2001; Garcia et al. 2000, 2002; He et al. 2005; Karagiorgou et al. 2005; Lazarova et al. 2005; Lipowska et al. 2004; Mandal et al. 1998; Mundwiler et al. 2005; Schibli et al. 2002; Stephenson et al. 2003; Stichelberger et al. 2003; van Staveren et al. 2004, 2005; Fig. 2.2.1). Bidentate ligands have proven to be very fast coordinating entities, in particular if they are of anionic nature. Tridentate ligands do not display significantly higher thermodynamic stability than bidentate chelates do. However, their reaction rate is
27
28
2.2 The Technetium and Rhenium Tricarbonyl Core
Fig. 2.2.1. Various ligand bifunctional, tridentate chelating systems designed for the coupling to biomolecules and subsequent radiolabeling with the [M(OH2)3(CO)3]+ (coordinative atoms in boldface). Single amino acid chelates (SAAC): R'' CO2H, R''' NH2
much faster, which becomes the decisive point for radiopharmaceutical application. In that respect, tridentate ligands are favored. In addition, tridentate ligands shield the organometallic metal center from, e.g., in vivo-observed crossreactivity with serum proteins, as observed in the case for complexes of the general formula [M(OH2)(L2)(CO)3] (L2 bidentate chelate) (Schibli et al. 2000). It has been observed that 99mTc-tricarbonyl complexes, which are coordinated with a tridentate chelating system, reveal good stability when challenged in human plasma and with excess cysteine, histidine, or glutathione. These complexes show also very good clearance form the blood pool and all tissue and organs when tested in BALB/c mice. In contrast, complexes, which are coordinated in a bidentate fashion, show significant aggregation with plasma proteins in vitro and in vivo. They are significantly retained in the blood and in the organs of excretion such as the liver and the kidneys. These differences may be related to the susceptibility of the third, nonchelating coligand (H2O) to exchange with more reactive functional groups in vivo, allowing the 99mTc to be retained in tissues (Pietzsch et al. 2000; Schibli et al. 1999). For both reasons mentioned above, many groups are focusing on the development of novel, potent, tridentate chelates and tridentate BFCAs tailor-made for the M(CO)3 fragment. Egli et al. (1999) have investigated the ability of amino acids and amino acid fragments to react with the 99mTc-tricarbonyl core. The most important finding was that histidine reacts quantitatively with the organometallic precursor at very low concentrations (10±6 M). In an effort to create novel, bifunctional analogues of histidine, Alberto et al. recently derivatized histidine by introducing various functional groups at the e-N of the imidazole ring (Alberto et al. 2004; van Staveren et al. 2004). Attachment of these histidine derivatives to the C or N terminus of peptides is an elegant approach, and at the same time liberates both the a-amino group and carboxyl group to participate in tridentate chelation along with the d-N of the imidazole ring. A similar strategy was applied for S-functionalized cysteine BFCAs (van Staveren et al. 2005). Although the amino acid cysteine (and methionine) per se was found to be a rather ªslowº coordinating ligand, the situation changed significantly if the sulfur group of cysteine was functionalized. Valliant and Zubieta developed BFCAs for the Tc(CO)3 core, based on a lysine backbone comprising pyridyl, imidazole, thiolate, carboxylate groups, etc., for the specific purpose of conjugation to small peptides by solid-phase synthetic methods (Banerjee et
Chapter 2 Technetium in Medicine
al. 2002, 2004, 2005 a, b; Stephenson et al. 2003, 2004; Wei et al. 2005). A whole library of such single amino acid chelates (SAAC) derivatives of lysine has been prepared and readily conjugated to small peptides. The organometallic nature of the M(CO)3 core also allows the introduction and combination with other nonclassic organometallic ligands, such as cyclopentadienes (cp) or cyclopentadienyls (cp±). Cp± is one of the smallest ligands with a low molecular weight, but is able to occupy three coordination sites. Complexes of the cymantrene type [CpM(CO)3] (M Tc, Re) are stable in physiological media (Wenzel 1992; Wenzel et al. 1993, 1994). Cps can also be further derivatized with, e.g., an acetyl group (Bernard et al. 2003) (Fig. 2.2.2). The acetyl group can act as an anchoring group for biomolecules, giving rise to cp biomolecule conjugates. Reaction of such cp derivatives with [99mTc(OH2)3(CO)3]+ in aqueous media formed the corresponding radiolabeled conjugates in high yields, but at relatively high ligand concentrations (10±4 to 10±3 M) (Bernard et al. 2003). Valliant's group has recently built an interesting link between boron neutron capture therapy and diagnostic radiopharmacy (Fig. 2.2.2). The carborane 3-isocyano-1,2-dicarba-closo-dodecaborane and functionalized derivatives thereof react with [99mTc(OH2)3 (CO)3]+ under basic conditions quantitatively (Sogbein et al. 2004, 2005 a, b). If the carboranes were coupled to targeting biomolecules, this approach would secure first the site-specific delivery of high quantities of boron atoms and second to quantify and to visualize the distribution of boron conjugates, a task that is not easily verified with nonradiolabeled boron compounds. Both types of nonclassic ligand systems, cps, and carboranes became only useful for radiopharmacy because of their reactivity with the novel synthon [M(OH2)3(CO)3]+. The tricarbonyl technology not only provides new opportunities with respect to the use of ªexoticº ligand systems, but it also opens perspectives for novel labeling strategies. The group at the Paul Scherrer Institute and Plçckthun et al. have successfully developed a direct labeling protocol employing [99mTc(OH2)3(CO)3]+ for scFvs and ªmini-antibodiesº (bi- and trivalent constructs of scFv) carrying an N- or a C-terminal His-tag (Deyev et al. 2003; Waibel et al. 2000; Willuda et al. 1999, 2001). The method is particu-
Fig. 2.2.2. Aqueous-base preparation of M(CO)3 complexes comprising nonclassic ligand systems such as functionalized carboranes and cyclopentadienyls
29
30
2.2 The Technetium and Rhenium Tricarbonyl Core
larly elegant and versatile, because His-tags are frequently genetically expressed for ease of purification of the protein on a nickel affinity column. This His-tag can be considered as a multidentate ligand, since two or more imidazoles from histidine can coordinate the metal centre (Fig. 2.2.3). Mixing of such an His-tag protein with [99mTc(OH2)3(CO)3]+ in buffer at 37 8C for 15 min resulted in > 90 % stable and specific incorporation of the total activity. This gentle procedure allows for the first time the radiolabeling of recombinant proteins ªfrom the shelf º, thus, without any chemical modification of the protein structure. The procedure is convenient for the quick and noninvasive evaluation of targeting proteins. An approach that is particularly interesting for radiolabeling of receptor-targeting radiopharmaceuticals with high specific activity is based on a peculiarity of functionalized aliphatic amines. It was observed that ternary amines involved in the coordination of the 99mTc(CO)3 fragment are cleaved from a solid-phase support during the labeling reaction. It could be shown that metal-assisted cleavage allows the preparation of essentially carrier-free complexes or bioconjugates (Mundwiler et al. 2004). Cleavage occurs exclusively with technetium but not with rhenium. Typical yields of these processes varied between 10 and 50%, relative to the total activity of 99mTc (Fig. 2.2.4). Mixed-ligand approaches are well documented for Tc and Re in higher oxidation states. The M(CO)3 fragment allows a similar possibility. As mentioned earlier, the water ligand in complexes of the type [M(OH2)(L2)(CO)3] (L2 bidentate chelate) is loosely bound and can be exchanged by a potent monodentate ligand (L1), forming complexes of the general formula [M(L1)(L2)(CO)3]. Either L1 or L2 can be readily coupled to biomolecules (Mundwiler et al. 2004; Fig. 2.2.5). Several problems have been addressed with this ª2+1 approachº: (1) the functionalization of biomolecules is minimized or simplified, (2) the resulting complexes/bioconjugates are coordinatively saturated, and (3) further flexibility with respect to the fine-tuning of the physicochemical properties of the radiopharmaceutical is possible.
Fig. 2.2.3. Model of the potential coordination of the M(CO)3 core to His5-tag of a recombinantly produced protein. Purple technetium, bright blue nitrogen, red oxygen, gray carbon
Chapter 2 Technetium in Medicine
Zubieta and coworkers have recently taken advantage of the fluorescent and luminescent properties of organometallic complexes of rhenium (and technetium) comprising certain aromatic ligand systems (Fig. 2.2.6). The nonradioactive natRe(CO)3 bioconjugates with a formyl peptide receptor-targeting peptide (fMLF), enabeled visualization
Fig. 2.2.4. Tc(CO)3-assisted cleavage of solid-phase bound biomolecules functionalized with an aliphatic triamine chelate, leading to high specific activity of radiotracer
Fig. 2.2.5. Schematic drawing of mixed-ligand approaches using combination of mono- and bidentate ligand systems coupled to biomolecules
Fig. 2.2.6. Formyl peptide receptor-targeting peptide (fMLF)[(SAACQ-M(CO)3)+] conjugate useful for in vitro fluorescent microscopy (where M = natRe) and in vivo single-photon emission computer tomography (SPECT) (where M = 99mTc) with isostructural technetium and rhenium complexes
31
32
2.2 The Technetium and Rhenium Tricarbonyl Core
of receptor targeting on the cellular level by means of fluorescent microscopy (Stephenson et al. 2004). The isostructural bioconjugate in the radiolabeled form (with the 99m Tc(CO)3 core) allowed the noninvasive detection of corresponding cancer sites in vivo via single-photon emission tomography. Hence, the tricarbonyl technology allows bridging the intrinsic gap between in vitro and in vivo imaging.
2.2.1 Bioconjugates Comprising the M(CO)3 Core The number of technetium and rhenium tricarbonyl compounds in preclinical evaluation is remarkable. These efforts comprise small molecules as well as macromolecules useful in diagnostic and/or therapeutic nuclear medicine. There are also clinical data available with tumor affine peptides such as neurotensin receptor- and somatostatin receptor-targeting peptides radiolabeled with the 99mTc(CO)3 core. Dopamine transporter ligand DAT and the 5-HT1A serotonergic receptor ligand WAY100635 have been, and are still, subjects of intense investigation in conjunction with the carbonyl labeling technology (Fig. 2.2.7). WAY100635, has been functionalized with cyclopentadiene and bidentate Schiff-base chelates (Alberto et al. 1999; Arterburn et al. 2003; Bernard et al. 2003; Bigott et al. 2005). The conjugates revealed an IC50 value in the low-nanomolar range toward the 5-HT1A receptor. For the preparation of the cp-arylpiperazine derivative, a one-pot, single-step synthesis was described (yields > 95%), starting directly from aqueous [99mTcO4]±, applying the strategy illustrated in Fig. 2.2.2 (Wald et al. 2001). In vitro the receptor affinity and the selectivity of the organometallic derivatives were preserved. However, in vivo the compounds displayed insufficient brain uptake. Metal carbonyl complexes of steroids have been synthesized by the groups of Johannsen and Katzenellenbogen (Arterburn et al. 2003; Bigott et al. 2005; Luyt et al. 2003; Wust et al. 1998, 1999). Various 17b-progesterone and 7a-estradiole dithioether and cyclopentadiene complexes of technetium/rhenium(I) tricarbonyl have been pre-
Fig. 2.2.7. Examples of organometallic Tc-99m central nervous system (CNS) complexes
Chapter 2 Technetium in Medicine
Fig. 2.2.8. Structure of various organometallic steroids for potential radiodiagnostic and radiotherapeutic targeting of progesterone receptor (PR)- and estrogen receptor (ER)-positive cancer
pared and tested (Fig. 2.2.8). The relative binding affinity (RBA) was found to depend on the nature of the spacer between the metal chelate and the steroid moiety. Similar observation and tendencies have been reported for the progestin complexes (Wust et al. 1999). For both examples, the organometallic cyclopentadienyl±tricarbonyl systems were superior to the dithioether-tricarbonyl in terms of RBA for the corresponding receptors. Synthesis and biodistribution studies of the corresponding Tc-99m and even Tc-94m analogues have been performed that suggested limited usefulness of these systems as effective imaging agents for progesterone receptor (PR)- and estrogen receptor (ER)-positive breast cancer. Schibli and coworkers and other groups have recently published organometallic folate derivatives for targeting a-folate receptor over expressing cancer cells (Mçller et al. 2004). Preclinical in vivo single-photon emission computer tomography (SPECT)/CT studies in tumor-bearing mice have revealed almost identical pharmacokinetics for both Tc-99m and the homologous Re-188 folate (Fig. 2.2.9). Based on these in vivo results and results of other organometallic Tc-99m/Re-188-labeled biomolecules (vide infra), it is reasonable to propose that for the tricarbonyl technology, the concept of the ªmatched pairº Tc/Re is indeed valid in various aspects. Alberto and coworkers have demonstrated that vitamin B12, essential for tumor growth, can be functionalized at several positions and radiolabeled with a Tc(CO)3 core (Kunze et al. 2004; van Staveren et al. 2004). The in vivo assessment of several promising derivatives is currently under investigation. The most thoroughly studied class of biomolecules that was tested with the tricarbonyl technology was the tumor affine peptides. Peptides reveal biological and pharmacological characteristics (e.g., biological half-life), which are very suited for the imaging and therapy with Tc-99m or Re-188. In fact, peptides have been among the first examples for the efficient labeling with the M(CO)3 core. A number of other peptides have been studied in detail, such as neurotensin, bombesin, octreotide, annexin (Biechlin et al. 2005; Tait et al. 2002), and neuropeptide Y. Neurotensin and stabilized derivatives thereof were derivatized with histidine, either through an amide bond to the carboxylic
33
Fig. 2.2.9. Time-dependent biodistribution of novel sing KB-cell xenografts
99m
Tc/188Re organometallic folate derivatives in nude mice bearing folate receptor overexpres-
34 2.2 The Technetium and Rhenium Tricarbonyl Core
Chapter 2 Technetium in Medicine
acid to produce a bidentate NN chelator or through alkylation at the N-amino group in order to retain the tripodal coordinating feature (Blauenstein et al. 2004; Bruehlmeier et al. 2002; Egli et al. 1999; Garcia-Garayoa et al. 2001, 2002; Waibel et al. 2000). Biodistribution studies with Tc-99m showed that tridentate ligands are superior to bidentate ones, which is in agreement with the findings and preferences mentioned previously. A phase I clinical study is ongoing with 99mTc-labeled neurotensin derivatives. Neurotensin analogues with improved pharmacological profiles are currently employed in preclinical therapy studies with 188Re(CO)3. 0 Tyr3octreotate analogues functionalized with various BFCA have been tested (Marmion et al. 1999). The BFCA gave rise to complexes of different overall charge (+1 to ±3). Wester et al. have coupled picoline-aminoacetic acid to a carbohydrated octreotide. The carbohydrate makes the conjugate much more hydrophilic, and an excellent biodistribution in humans was observed (Wester 2003; Wester et al. 2001). Bombesin was derivatized at the C terminus with bidentate chelators (Smith et al. 2003 a, b). The labeled peptide fully retained the biological activity and was stable in vitro and in vivo. Since the bidentate coordination is not optimal with respect to stability (pharmacokinetics), the coordination sphere of the metal tricarbonyl core has been saturated with a highly hydrophilic phosphine. This additional coordination is an example of the 2+1 approach mentioned in the previous section. The mixed-ligand approach resulted in significantly higher hydrophilicity of the radioconjugates and an improved biodistribution labeled with Tc-99m and also with Re-188 (Smith et al. 2003). In the case of other receptor avid peptides and proteins, which express an endogenous histidine such as, e.g., bombesin or neuropeptide Y, the pronounced avidity of the tricarbonyl core for histidine can create a problem with unspecific binding (Langer et al. 2001; La Bella et al. 2002 a, b). Prelabeling procedures can circumvent these problems (Langer et al. 2001). However, Garcia et al. could show that a site-specific postlabeling of bombesin is possible by introduction of a potent tridentate ligand such as, e.g., the Na-Ac-histidine at the N terminus of the peptide (La Bella et al. 2002). As a result, a single, stable species was formed, and unspecific labeling was negligible. The high efficiency combined with the mild reaction conditions applicable with [M(OH2)3(CO)3]+ is very attractive for radiolabeling of sensitive proteins. This has been recognized by several groups. MUC1 mucin is upregulated and abnormally glycosylated in bladder cancer, and is a promising target for intravesical radioimmunotherapy. The in vivo results in tumor mice have clearly revealed a better retention of immunoreactivity of the 188Re(CO)3-labeled monoclonal antibody (mAb) as compared with the 2-mercaptoethanol-reduced-and-Re(V)-labeled mAb (Murray et al. 2001). The surfactant protein B was nonspecifically labeled with [99mTc(OH2)3(CO)3]+. The highly lipophilic protein has potential in the diagnosis of acute respiratory disease syndrome (Amann et al. 2001). Waibel et al. and Deyev et al. have pioneered the use of site-specific labeling of recombinant proteins via a multi±His-tag (Willuda et al. 2001). The ease of radiolabeling is remarkable and unmet with any other technetium methodology (Deyev et al. 2003). In conclusion, it is apparent that organometallic compounds are a valuable and realistic alternative for the labeling of biomolecules in, e.g., radiopharmacy. The encouraging results of preclinical and clinical studies with organometallic-labeled tumor affine peptides and vitamins build the scaffold for further investigations. The tricarbonyl technology is the creative precedent of such novel techniques. However, the perspective and potential of organometallic labeling techniques in nuclear medicine will also depend on the success of new compounds for therapeutic use and the availability of ap-
35
36
2.2 The Technetium and Rhenium Tricarbonyl Core
propriate radionuclides. In the future, chemists and radiopharmacists will be equally challenged to exploit the aqueous organometallic chemistry of potential radionuclides to develop novel techniques and compounds for diagnostic and therapeutic application.
References Alberto R, Schibli R, Egli A, Schubiger PA, Herrmann WA, Artus G, Abram U, Kaden TA (1995) Metal carbonyl syntheses XXII. Low-pressure carbonylation of [MOCl4]± and [MO4]±: the technetium(I) and rhenium(I) complexes [NEt4]2[MCl3(CO)3]. J Organomet Chem 493:119±127 Alberto R, Schibli R, Egli A, Schubiger AP, Abram U, Kaden TA (1998) A novel organometallic aqua complex of technetium for the labeling of biomolecules: synthesis of [99mTc(OH2)3 (CO)3]+ from (TcO4)± in aqueous solution and its reaction with a bifunctional ligand. J Am Chem Soc 120:7987±7988 Alberto R, Schibli R, Schubiger AP, Abram U, Pietzsch HJ, Johannsen B (1999) First application of fac-[99mTc(OH2)3(CO)3]+ in bioorganometallic chemistry: design, structure, and in vitro affinity of a 5-HT1A receptor ligand labeled with Tc-99m. J Am Chem Soc 121:6076±6077 Alberto R, Schibli R, Waibel R, Abram U, Schubiger AP (1999) Basic aqueous chemistry of M(OH2)3(CO)+3 (M Re, Tc) directed towards radiopharmaceutical application. Coord Chem Rev 192:901±919 Alberto R, Ortner K, Wheatley N, Schibli R, Schubiger AP (2001) Synthesis and properties of boranocarbonate: A convenient in situ CO source for the aqueous preparation of [99mTc(OH2)3 (CO)3]+. J Am Chem Soc 123:3135±3136 Alberto R, Pak JK, van Staveren D, Mundwiler S, Benny P (2004) Mono-, bi-, or tridentate ligands? The labeling of peptides with Tc-99m-carbonyls. Biopolymers 76:324±333 Alves S, Paulo A, Correia JDG, Gano L, Smith CJ, Hoffman TJ, Santos I (2005) Pyrazolyl derivatives as bifunctional chelators for labeling tumour-seeking peptides with the fac-M(CO)+3 moiety (M = Tc-99m, Re): synthesis, characterization, and biological behavior. Bioconjugate Chem 16:438±449 Amann A, Decristoforo C, Ott I, Wenger M, Bader D, Alberto R, Putz G (2001) Surfactant protein B labelled with 99mTc(CO)3(H2O)+3 retains biological activity in vitro. Nucl. Med. Biol. 28:243±250 Arterburn JB, Corona C, Rao KV, Carlson KE, Katzenellenbogen JA (2003) Synthesis of 17-alphasubstituted estradiol-pyridin-2-yl hydrazine conjugates as effective ligands for labeling with Alberto's complex fac-Re(OH2)3(CO)+3 in water. J Org Chem 68:7063±7070 Banerjee SR, Levadala MK, Lazarova N, Wei LH, Valliant JF, Stephenson KA, Babich JW, Maresca KP, Zubieta J (2002) Bifunctional single amino acid chelates for labeling of biomolecules with the [Tc(CO)3]+ and [Re(CO)3]+ cores. Crystal and molecular structures of ReBr(CO)3(H2NCH2C5H4N), Re(CO)3[(C5H4NCH2)2NH] Br, Re(CO)3[(C5H4NCH2)2NCH2CO2H] Br, Re(CO)3[X(Y)NCH2CO2CH2CH3] Br (XY=2-pyridylmethyl; X=2-pyridyimethyl, Y=2-(1-methylimidazolyl)methyl; X Y=2-(1-methylimidazolyl)methyl), ReBr(CO)3[(C5H4NCH2)NH(CH2C4H3S)], and Re(CO)3 [(C5H4NCH2)N(CH2C4H3S)(CH2CO2)]. Inorg Chem 41:6417±6425 Banerjee SR, Babich JW, Zubieta J (2004) Bifunctional chelates with aliphatic amine donors for labeling of biomolecules with the [Tc(CO)3]+ and [Re(CO)3]+ cores: the crystal and molecular structure of Re(CO)3[(H2NCH2CH2)2N(CH2)4CO2Me]. Br Inorg Chem Commun 7:481±484 Banerjee SR, Babich JW, Zubieta J (2005a) Site directed maleimide bifunctional chelators for the M(CO)+3 core (M=Tc-99m, Re). Chemical Commun 13:1784±1786 Banerjee SR, Schaffer P, Babich JW, Valliant JF, Zubieta J (2005b) Design and synthesis of site directed maleimide bifunctional chelators for technetium and rhenium. Dalton Transactions 3886±3897 Bernard J, Ortner K, Spingler B, Pietzsch HJ, Alberto R (2003) Aqueous synthesis of derivatized cyclopentadienyl complexes of technetium and rhenium directed toward radiopharmaceutical application. Inorg Chem 42:1014±1022 Biechlin ML, d'Hardemare AD, Fraysse M, Gilly FN, Bonmartin A (2005) Improvement in radiolabelling proteins with the Tc-99m-tricarbonyl-core 99mTc(CO)+3 , by thiol-derivatization with iminothiolane: application to gamma-globulins and annexin V. J Labelled Compd Radiopharm 48:873±885 Bigott HM, Parent E, Luyt LG, Katzenellenbogen JA, Welch MJ (2005) Design and synthesis of functionalized cyclopentadienyl tricarbonylmetal complexes for technetium-94m PET imaging of estrogen receptors. Bioconjugate Chem 16:255±264
Chapter 2 Technetium in Medicine Blauenstein P, Garayoa EG, Ruegg D, Blanc A, Tourwe D, Beck-Sickinger A, Schubiger PA (2004) Improving the tumor uptake of Tc-99m-labeled neuropeptides using stabilized peptide analogues. Cancer Biother Radiopharm19:181±188 Bruehlmeier M, Garayoa EG, Blanc A, Holzer B, Gergely S, Tourwe D, Schubiger PA, Blauenstein P (2002) Stabilization of neurotensin analogues: effect on peptide catabolism, biodistribution and tumor binding. Nucl Med Biol 29:321±327 Correia JDG, Domingos A, Santos I, Alberto R, Ortner K (2001) Re tricarbonyl complexes with ligands containing P,N,N and P,N,O donor atom sets: synthesis and structural characterization. Inorg Chem 40:5147±5151 Deyev SM, Waibel R, Lebedenko EN, Schubiger AP, Pluckthun A (2003) Design of multivalent complexes using the barnase-barstar module. Nat Biotechnol 21:1486±1492 Egli A, Hegetschweiler K, Alberto R, Abram U, Schibli R, Hedinger R, Gramlich V, Kissner R, Schubiger PA (1997) Hydrolysis of the organometallic aqua ion fac-triaquatricarbonylrhenium(I). Mechanism, pKa, and formation constants of the polynuclear hydrolysis products. Organometallics 16:1833±1840 Egli A, Alberto R, Tannahill L, Schibli R, Abram U, Schaffland A, Waibel R, Tourwe D, Jeannin L, Iterbeke K, Schubiger PA (1999) Organometallic Tc-99m-aquaion labels peptide to an unprecedented high specific activity. J Nuc Med 40:1913±1917 Garcia R, Paulo A, Domingos A, Santos I, Ortner K, Alberto R (2000) Re and Tc complexes containing B±H´M agostic interactions as building blocks for the design of radiopharmaceuticals. J Am Chem Soc 122:11240±11241 Garcia-Garayoa E, Allemann-Tannahill L, Blauenstein P, Willmann M, Carrel-Remy N, Tourwe D, Iterbeke K, Conrath P, Schubiger PA (2001) In vitro and in vivo evaluation of new radiolabeled neurotensin(8-13) analogues with high affinity for NT1 receptors. Nucl Med Biol 28:75±84 Garcia R, Xing YH, Paulo A, Domingos A, Santos I (2002) Rhenium(I) tricarbonyl complexes with mercaptoimidazolylborate ligands bearing piperazine fragments. Dalton Transactions 22:4236± 4241 Garcia-Garayoa E, Blauenstein P, Bruehlmeier M, Blanc A, Iterbeke K, Conrath P, Tourwe D, Schubiger PA (2002) Preclinical evaluation of a new, stabilized neurotensin(8-13) pseudopeptide radiolabeled with Tc-99m. J Nuc Med 43:374±383 He HY, Lipowska M, Xu XL, Taylor AT, Carlone M, Marzilli LG (2005) Re(CO)3 complexes synthesized via an improved preparation of aqueous fac-Re(CO)3(H2O)+3 as an aid in assessing Tc99m imaging agents. Structural characterization and solution behavior of complexes with thioether-bearing amino acids as tridentate ligands. Inorg Chem 44:5437±5446 Karagiorgou O, Patsis G, Pelecanou M, Raptopoulou CP, Terzis A, Siatra-Papastaikoudi T, Alberto R, Pirmettis I, Papadopoulos M (2005) S-(2-(2'-pyridyl)ethyl)cysteamine and S(2-(2 '-pyridyl)ethyl)d,l-homocysteine as ligands for the ªfac-M(CO)+3 ª (M = Re, 99mTc) Core Inorg Chem 44:4118±4120 Kunze S, Zobi T, Kurz P, Spingler B, Alberto R (2004) Vitamin B12 as a ligand for technetium and rhenium complexes. Angew Chem Int Edit 43:5025±5029 La Bella R, Garcia-Garayoa E, Bahler M, Blauenstein P, Schibli R, Conrath P, Tourwe D, Schubiger PA (2002 a) A Tc-99m(I)-postlabeled high affinity bombesin analogue as a potential tumor imaging agent. Bioconjugate Chem 13:599±604 La Bella R, Garcia-Garayoa E, Langer M, Blauenstein P, Beck-Sickinger AG, Schubiger PA (2002 b) In vitro and in vivo evaluation of a Tc-99m(I)-labeled bombesin analogue for imaging of gastrin releasing peptide receptor-positive tumors. Nucl Med Biol 29:553±560 Langer M, La Bella R, Garcia-Garayoa E, Beck-Sickinger AG (2001) Tc-99m-labeled neuropeptide Y analogues as potential tumor imaging agents. Bioconjugate Chem 12:1028±1034 Lazarova N, Babich J, Valliant J, Schaffer P, James S, Zubieta J (2005) Thiol- and thioether-based bifunctional chelates for the [M(CO)+3 core (M Tc, Re). Inorg Chem 44:6763±6770 Lipowska M, Cini R, Tamasi G, Xu XL, Taylor AT, Marzilli LG (2004) Complexes having the fac[M(CO)3]+ core (M = Tc, Re) useful in radiopharmaceuticals: X-ray and NMR structural characterization and density functional calculations of species containing two sp3 N donors and one sp3 O donor. Inorg Chem 43:7774±7783 Luyt LG, Bigott HM, Welch MJ, Katzenellenbogen JA (2003) 7 alpha- and 17 alpha-substituted estrogens containing tridentate tricarbonyl rhenium/technetium complexes: Synthesis of estrogen receptor imaging agents and evaluation using MicroPET with technetium-94m. Bioorg Med Chem 11:4977±4989 Mandal SK, Ho DM, Qing LG, Orchin M (1998) The preparation and crystal structure of (dppe) (CO)3Re-OC(O)O-Re(CO)3(dppe). Polyhedron 17:607±611 Marmion ME, Alberto R, Bugaj J, Chinen L, Schmidt M, Srinivasan A (1999) Preparation and biodistribution of [99mTc(CO)3His0,Tyr3]octreotate. J Labelled Compd Radiopharm 42:S231±S233
37
38
2.2 The Technetium and Rhenium Tricarbonyl Core Mçller C, Hofmann U, Schubiger AP, Schibli R (2004) Organometallic 99mTc-technetium(I)- and Re-rhenium(I) folate derivatives for potential use in nuclear medicine. J Organomet Chem 289:4712±4721 Mundwiler S, Candreia L, Hafliger P, Ortner K, Alberto R (2004) Preparation of no-carrier-added technetium-99m complexes via metal-assisted cleavage from a solid phase. Bioconjugate Chem 15:195±202 Mundwiler S, Kundig M, Ortner K, Alberto R (2004) A new 2+1 mixed ligand concept based on 99mTc (OH2)3(CO)+3 : a basic study. Dalton Transactions 1320±1328 Mundwiler S, Waibel R, Spingler B, Kunze S, Alberto R (2005) Picolylamine-methylphosphonic acid esters as tridentate ligands for the labeling of alcohols with the fac-M(CO)+3 core (M=Tc-99m, Re): synthesis and biodistribution of model compounds and of a Tc-99m-labeled cobinamide. Nucl Med Biol 32:473±484 Murray A, Simms MS, Scholfield DP, Vincent RM, Denton G, Bishop MC, Price MR, Perkins AC (2001) Production and characterization of Re-188-C595 antibody for radioimmunotherapy of transitional cell bladder cancer. J Nucl Med 42:726±732 Park SH, Seifert S, Pietzsch HJ (2006) Novel and efficient preparation of precursor Re-[188Re (H2O)3(CO)3]+ for the labeling of biomolecules. Bioconjugate Chem 17:223±225 Pietzsch HJ, Gupta A, Reisgys M, Drews A, Seifert S, Syhre R, Spies H, Alberto R, Abram U, Schubiger PA, Johannsen B (2000) Chemical and biological characterization of technetium(I) and rhenium(I) tricarbonyl complexes with dithioether ligands serving as linkers for coupling the Tc(CO)3 and Re(CO)3 moieties to biologically active molecules. Bioconjugate Chem 11:414±424 Schibli R, Katti KV, Higginbotham C, Volkert WA, Alberto R (1999) In vitro and in vivo evaluation of bidentate, water-soluble phosphine ligands as anchor groups for the organometallic fac[99mTc(CO)3]+core. Nucl Med Biol 26:711±716 Schibli R, La Bella R, Alberto R, Garcia-Garayoa E, Ortner K, Abram U, Schubiger PA (2000) Influence of the denticity of ligand systems on the in vitro and in vivo behavior of Tc-99m(I)-tricarbonyl complexes: a hint for the future functionalization of biomolecules. Bioconjugate Chem 11:345±351 Schibli R, Schwarzbach R, Alberto R, Ortner K, Schmalle H, Dumas C, Egli A, Schubiger AP (2002) Steps toward high specific activity labeling of biomolecules for therapeutic application: preparation of precursor [188Re(H2O)3(CO)3]+ and synthesis of tailor-made bifunctional ligand systems. Bioconjugate Chem 13:750±756 Smith CJ, Sieckman GL, Owen NK, Hayes DL, Mazuru DG, Kannan R, Volkert WA, Hoffman TJ (2003 a) Radiochemical investigations of gastrin-releasing peptide receptor-specific 99mTc(X)(CO)3-DprSer-Ser-Ser-Gln-Trp-Ala-Val-Gly-His-Leu-Met-(NH2) in PC-3, tumor-bearing, rodent models: syntheses, radiolabeling, and in vitro/in vivo studies where Dpr = 2,3-diaminopropionic acid and X H2O or P(CH2OH)3. Cancer Res 63:4082±4088 Smith CJ, Sieckman GL, Owen NK, Hayes DL, Mazuru D, Volkert WA, Hoffman TJ (2003 b) Radiochemical investigations of 188Re(H2O)(CO)3-diaminopropionic acid-SSS-bombesin(7-14)NH2: syntheses, radiolabeling and in vitro/In vivo GRP receptor targeting studies. Anticancer Res 23:63±70 Sogbein OO, Merdy P, Morel P, Valliant JF (2004) Preparation of Re(I)- and Tc-99m(I)-metallocarboranes in water under weakly basic reaction conditions. Inorg Chem 43:3032±3034 Sogbein OO, Green AEC, Schaffer P, Chankalal R, Lee E, Healy BD, Morel P, Valliant JF (2005a) Synthesis of ortho- and meta-Re(I)-metallocarboranes in water. Inorg Chem 44:9574±9584 Sogbein OO, Green AEC, Valliant JF (2005b) Aqueous fluoride and the preparation of 99m Tc(CO)3(OH2)+3 and Tc-99m-carborane complexes. Inorg Chem 44:9585±9591 Maresca KP (2003) Bifunctional single amino acid chelates (SAAC) as synthons for the solid phase synthesis of Tc(I) and Re(I) radiopharmaceuticals. J Nucl Med 44:48P±48P Staveren DR van, Benny PD, Waibel R, Kurz P, Pak JK, Alberto R (2005) I-functionalized cysteine: powerful ligands for the labelling of bioactive molecules with triaquatricarbonyltechnetium99m 99mTc(CO)3(H2O)+3 . Helv Chim Acta 88:447±460 Staveren DR van, Mundwiler S, Hoffmanns U, Pak JK, Spingler B, Metzler-Nolte N, Alberto R (2004) Conjugation of a novel histidine derivative to biomolecules and labelling with 99m Tc(CO)3(H2O)+3 . Org Biomol Chem 2:2593±2603 Staveren DR van, Waibel R, Mundwiler S, Schubiger PA, Alberto R (2004) Conjugates of vitamin B12 with N-epsilon-functionalized histidine for labeling with [99mTc(OH2)3(CO)3]+: synthesis and biodistribution studies in tumor bearing mice. J Organomet Chem 689:4803±4810 Stephenson KA, Banerjee SR, Besanger T, Sogbein OO, Levadala MK, McFarlane N, Lemon JA, Boreham DR, Maresca KP, Brennan JD, Babich JW, Zubieta J, Valliant JF (2004) Bridging the
Chapter 2 Technetium in Medicine gap between in vitro and in vivo imaging: isostructural Re and Tc-99m complexes for correlating fluorescence and radioimaging studies. J Am Chem Soc 126:8598±8599 Stephenson KA, Valliant JF, Zubieta J, Banerjee SR, Levadala MK, Taggart L, Ryan L, McFarlane N, Boreham DR, Babich JW, Stephenson KA, Zubieta J, Banerjee SR, Levadala MK, Taggart L, Ryan L, McFarlane N, Boreham DR, Maresca KP, Babich JW, Valliant JF (2004) A new strategy, for the preparation of peptide-targeted radiopharmaceuticals based on ion of peptide-targeted an Fmoc-lysine-derived single amino acid chelate (SAAC). Automated solid-phase synthesis, NMR characterization, and in vitro screening of fMLF(SAAC)G and fMLF (SAAC-Re(CO)3)+G. Bioconjugate Chem 15:128±136 Stichelberger A, Waibel R, Dumas C, Schubiger PA, Schibli R (2003) Versatile synthetic approach to new bifunctional chelating agents tailor made for labeling with the fac-[M(CO)3]+ core (M = Tc, 99m Tc, Re): synthesis, in vitro, and in vivo behavior of the model complex [M(APPA)(CO)3] (appa [(5-amino-pentyl)-pyridin-2-yl-methyl-amino]-acetic acid). Nucl Med Biol 30:465±470 Tait JF, Smith C, Gibson DF (2002) Development of annexin V mutants suitable for labeling with Tc(I)-carbonyl complex. Bioconjugate Chem 13:1119±1123 Waibel R, Novak-Hofer I, Schibli R, Blauenstein P, Garcia-Garayoa E, Schwarzbach R, Zimmermann K, Pellikka R, Gasser O, Blanc A, Bruhlmeier M, Schubiger PA (2000) Radiopharmaceuticals for targeted tumor diagnosis and therapy. Chimia 54:683±688 Waibel R, Stichelberger R, Alberto R, Schubiger PA, Chester KA, Begent RHJ (2000) Site-directed labelling of single chain antibodies with 99(m)technetium and (188)rhenium. Eur J Nucl Med 27:15 Wald J, Alberto R, Ortner K, Candreia L (2001) Aqueous one-pot synthesis of derivatized cyclopentadienyl-tricarbonyl complexes of Tc-99m with an in situ CO source: application to a serotonergic receptor ligand. Angew Chem Int Edit 40:3062±3066 Wei LH, Babich J, Zubieta J (2005) Bifunctional chelates with mixed aromatic and aliphatic amine donors for labeling of biomolecules with the [Tc(CO)3]+ and [Re(CO)3]+-cores. Inorg Chim Acta 358:3691±3700 Wenzel M (1992) Tc-99m Labeling of cymantrene-analogs with different substituents ± a new approach to Tc-99m radiodiagnostics. J Labelled Compd Radiopharm 31:641±650 Wenzel M, Saidi M (1993) Esters of Tc-99m labeled cytectrenecarboxylic acid with alcohols of cyclic amines as cerebral radiodiagniostic agents. J Labelled Compd Radiopharm 33:77±80 Wenzel M, Klinge C (1994) Tc-99m-labeled estradiol derivatives ± synthesis, organ distribution and tumour affinity. J Labelled Compd Radiopharm 34:981±987 Wester HJ (2003) Carbohydrated peptides. Cancer Biother Radiopharm18:277±277 Wester HJ, Schottelius M, Schwaiger M (2001) 99mTc(CO)3-labeled carbohydrated SSTR-ligands: synthesis, internalization kinetics and biodistribution on a rat pancreatic tumor model. J Nucl Med 42:115P±115P Willuda J, Honegger A, Waibel R, Schubiger AP, Stahel R, Zangemeister-Wittke U, Pluckthun A (1999) High thermal stability is essential for tumour targeting of antibody fragments: Engineering of a humanized anti-epitelial glycoprotein-2 (epitelial cell adhesion molecule) singlechain Fv fragment. Cancer Res 59:5758±5767 Willuda J, Kubetzko S, Waibel R, Schubiger PA, Zangemeister-Wittke U, Pluckthun A (2001) Tumour targeting of mono-, di-, and tetravalent Anti-p185(HER-2) miniantibodies multimerized by self-associating peptides. J Biol Chem 276:14385±14392 Wust F, Carlson KE, Katzenellenbogen JA, Spies H, Johannsen B (1998) Synthesis and binding affinities of new 17 alpha-substituted estradiol-rhenium ªn+1º mixed-ligand and thioethercarbonyl complexes. Steroids 63:665±671 Wust F, Skaddan MB, Leibnitz P, Spies H, Katzenellenbogen JA, Johannsen B (1999) Synthesis of novel progestin-rhenium conjugates as potential ligands for the progesterone receptor. Bioorg Med Chem 7:1827±1835
39
40
2.3 Technetium Coupled to Biologically Active Molecules
2.3 Technetium Coupled to Biologically Active Molecules H.-J. Pietzsch, J.-U. Kçnstler and H. Spies
2.3.1 Introduction Many 99mTc pharmaceuticals were designed for the measurement of organ function, based on regional blood flows, ion transport, and cellular retention. Organ specificity is governed by molecular characteristics (e.g., size, shape, charge) and physiological factors. Primarily, these radiotracers are coordination complexes of technetium leaving either a positive or a negative charge; neutral, lipophilic complexes pass the bloodbrain barrier. Organ function is related to regional perfusion (e.g., brain, heart). Hepatocyte function is measured by the excretion of iminodiacetic acid (IDA) derivatives into bile, simulating the active transport of bilirubin. Increased osteogenic activity correlates with increased regional uptake of 99mTc-diphosphonate complexes in bone structures, delineating tumor and metastatic growth. The functional state of the kidneys as measured by active tubular secretion requires a negatively charged complex with a carboxylate anion. 99m Tc pharmaceuticals based on coordination complexes with functionalized ligands are also known as ªTc essentialsº; those concerning labeled particles and macromolecules are called ªTc-taggedº radiopharmaceuticals. A variety of chelating agents have been developed for complex formation with certain oxidation states of technetium, providing the structural requirements for uptake and retention (Schwochau 2000). Examples of Tc essentials are shown in Fig. 2.3.1. The outstanding interest in the development of novel 99mTc pharmaceuticals is documented in recent reviews (Hom and Katzenellenbogen 1997; Johannsen and Pietzsch 2002 a; Jurisson and Lydon 1999).
Fig. 2.3.1. ªTc essentialº radiopharmaceuticals in clinical use
Chapter 2 Technetium in Medicine
2.3.1.1 Target-Specific
99m
Tc Pharmaceuticals
Besides the merits of coordination complexes for diagnostic imaging, few applications of tumor diagnosis are in clinical use. The need for radiotracers binding specifically to epitopes expressed on tumor cells has grown over the past decade, promoting new labeling techniques, by which technetium is attached to biomolecules. Direct or random labeling of biologically active molecules with reduced technetium did not produce pharmacologically acceptable radiotracers. Therefore, some known 99m Tc complexes were specifically evaluated as potential chelating units, such as mercaptoacetyltriglycine (MAG3) and diaminodithiol (DADT). Prerequisites of an optimal chelator: · The ligand used as a chelator should not alter the in vivo characteristics of a biomolecule. · The chelate unit containing technetium should preferably be an integral part of the biomolecule (Johannsen and Pietzsch 2002 b). · The chelating unit should not affect the potency of the biomolecule. The design of site-specific technetium molecules may complete the quest for the optimal chelator in accordance with the target-specific biomolecule, combining the chemical and biological requirements for tumor imaging.
2.3.2 Factors Affecting In Vivo Performance Unlike 99mTc complexes, which are symmetric, small molecules (Schwochau 2000), labeled biomolecules might be asymmetric, integrating building blocks with distinct functions, such as a linker and the technetium chelating unit (Fig. 2.3.2).
Fig. 2.3.2. Schematic representation of a specific
99m
Tc biomolecule
The in vivo distribution of a 99mTc biomolecule is influenced by its chemistry and by biological factors. The chemical nature of the targeting domain determines uptake and retention in the biological system. Structural integrity includes both chemical and metabolic stability of the labeled conjugate. Thus, the ligand that is used as a chelator, the type of linker, and the biomolecule will determine the bioavailability of the radiotracer. Biological factors are related to the specific recognition of metal-based molecules, to membrane transport (particularly crossing the blood±brain barrier), clearance from nontarget sites, and high-affinity binding to tumor cell epitopes, permitting imaging and disease assessment (Ballinger 2002). In Vivo Stability versus Reactivity. Both the chelate unit and the organic moiety may undergo transformations in vivo. In the case of ª3+1º mixed-ligand complexes, the
41
42
2.3 Technetium Coupled to Biologically Active Molecules
monodentate thiol ligand is exchanged by other SH-containing compounds such as glutathione (Nock et al. 1999) or reacts with proteins (Seifert et al. 2001). In vivo transchelation has been observed with certain 99mTc complexes (methylenediphosphonate [MDP]/gluconate). Complexes with robust tetradentate chelate units have shown metabolic degradation, splitting off the whole chelate as observed with 99mTc-Trodat-1 (Kushner et al. 1999; Mu et al. 1999). Furthermore, the carbon bond between the linker and the tertiary nitrogen of the coordination shell may break, even during the labeling procedure, as recently reported for 99mTc tricarbonyl-labeled glucose (Pak and Alberto 2001). Transport across Cell Membranes. In the body, many interactions of the radiotracer with biological components exist, affecting regional uptake. Transport across membranes and binding affinity have to be verified in suitable models. Specific radiotracers are designed to use transporter-mediated processes for unidirectional uptake; generally, uptake into cells across membranes should be rapid. Lipophilicity. Lipophilicity of a radiotracer facilitates diffusion across membranes, particularly passing the blood±brain barrier, which is required for brain uptake. Receptor Binding. Receptor binding is based on high-affinity binding of the radiotracer molecule, which is an antagonist. Since receptor density in the brain is generally in the picomolar range, high specific activity is a prerequisite for receptor ligands. Displacement Studies. Enzyme-inhibition studies have similar requirements if the target molecule is an enzyme and the radiotracer used for quantification is an inhibitor. An alternate mechanism is based on substrate analogs, like 18F-FDG, which block enzymatic degradation, thus facilitating quantification.
2.3.3 Chelate Units in the Design of Target-Specific 99mTc Pharmaceuticals Tc chelates suitable for conjugate formation with biomolecules are derived from Tc in oxidation states V, III, and I. Organometallic carbonyl (CO) complexes serve as precursors for the synthesis of 99mTc(I) pharmaceuticals (Sect. 2.2). Oxotechnetium(V) Complexes. The dominant structural element is the oxotechnetium core, TcO3+. The presence of the oxo ligand has a significant effect on the structure and stability of these complexes. DADT-derived ligands have found application in nuclear medicine because of the thiophilic nature of technetium for the thiolate donor group (Schwochau 2000) (Fig. 2.3.3). Tetradentate diaminodithiol (N2S2) forms neutral, lipid-soluble technetium complexes ± the most prominent is the ethylcysteinate dimer (ECD) ± used for the measurement of brain perfusion. The combination of an amine-N or amide-N in an N2S2 arrangement (monoamine, monoamine [MAMA]) results in a more polar derivative than the diaminedithiol system. This might be preferable when less lipophilicity is required, e.g., for labeling of proteins. Tripeptides combine donor atoms of different reactivity (e.g., N3S, N4). The prototypic N3S chelator MAG3 forms
Chapter 2 Technetium in Medicine
Fig. 2.3.3. Different types of oxotechnetium(V) chelates derived from N,S-ligands for radiotracer design. R spacer + targeting domain, R' H, alkyl, aryl
the radiopharmaceutical [TcO(MAG3)]±, which is used for studies of renal tubular function (Fig. 2.3.1). Mixed-ligand complexes were synthesized in order to reduce the synthetic expenditure necessary for tetradentate compounds. A combination of tridentate (S3 or NS2) and monodentate (thiol) ligands is employed in the so-called ª3+1º complexes (Spies et al. 1999). While the oxotechnetium/tridentate unit is very stable, exchange of the monodentate ligand has been observed in vivo (Nock et al. 1999; Syhre et al. 1998). Tc(V) Hydrazino Nicotinamide (HYNIC) Derivatives. The introduction of the Tc(V)HYNIC system (Schwartz et al. 1991) represents a milestone in the development of Tc99m radiopharmaceuticals. Particularly, peptides have been labeled with very high specific activity (Edwards et al. 1999 a; Harris et al. 1999; Rose et al. 1998). Since the HYNIC linker occupies only one coordination site, coligands such as tricine, ethylenediamine diacetic acid (EDDA), etc., may complete the coordination sphere of the metal (Babich et al. 2000; Edwards et al. 1999 b; Ono et al. 2000) (Fig. 2.3.4). Nitridotechnetium(V) Heterocomplexes. An asymmetric nitridotechnetium(V) heteromoiety has been proposed for radiolabeling bioactive molecules (Bolzati et al. 2000, 2002; Boschi et al. 2001; Pasqualini et al. 1992, 1994; Refosco et al. 2000). The metal fragment [Tc(N)(PXP)]2+ can be used as an efficient synthon for the preparation of a series of nitrido heterocomplexes containing bidentate chelators such as dithiocarbamates, dithiocarbazates, cysteine, and dithiolates (Bolzati et al. 2004; Boschi et al. 2005; Tisato et al. 2004) (Fig. 2.3.5).
43
44
2.3 Technetium Coupled to Biologically Active Molecules
Fig. 2.3.4. Proposed structures of various coligands. R biomolecule
99m
Tc-hydrazino nicotinamide (HYNIC) tricine derivatives with
Fig. 2.3.5. Schematic representation of the labeling approach using the novel [Tc(N)(PXP)]2+ moiety
Tc(III) Complexes. A novel type of Tc(III) chelate formed by the tripodal chelator 2,2',2''-nitrilotris(ethanethiol) and a tertiary phosphine or an isocyanide as coligands contains sterically well-shielded oxo-free Tc(III) (Fig. 2.3.6) (Pietzsch et al. 2001 a; Seifert et al. 2004; Spies et al. 1999). This moiety fulfils the requirements of a nonpolar building block stable against ligand exchange reactions in vivo. Another type of neutral Tc(III) complexes derived from the reaction of oxotechnetium(V) ª3+1º precursors with tertiary phosphines, namely compounds of the general formula [M(PR3)(SES)(SR)] (SES = tridentate dithiol ligand; E = S, NR, O), suffers from instability against cysteine and glutathione (Pietzsch et al. 2001 b; Seifert et al. 2000). Stability of this class of compounds can be enhanced when a bidentate P,S phosphinothiol ligand is used instead of the monodentate ligand. The resulting ª3+2º coordinated Tc(III) mixed-ligand complexes have the general formula [Tc(SES)(R2PS)] (Pietzsch et al. 2003) (Fig. 2.3.7). Tc(I) Complexes. The organometallic ligand cyclopentadienyl (cp) offers advantages because of its small size and low molecular weight (Wenzel and Klinge 1994). Stable Re(cp) and Tc(cp) complexes have been prepared that were conjugated to octreotide (Spradau et al. 1999), piperidine (Fig. 2.3.8) (Saidi et al. 2001), tropane (Cesati et al. 2002), and steroid hormones (LeBideau et al. 2001; Mull et al. 2002). However, this approach still suffers from unacceptable reaction conditions for routine use of technetium-99m.
Chapter 2 Technetium in Medicine
Fig. 2.3.6. Formation of technetium(III) complexes with tetradentate/monodentate coordination
Fig. 2.3.7. Reaction routes to Tc(III) complexes with ª3+2º coordination. E = N(CH3), S
Fig. 2.3.8. Preparation of 99mTc(CO)3 cyclopentadienyl (cp) carboxylate derivative illustrating the double-ligand transfer approach (Saidi 2001; Wenzel 1994)
45
46
2.3 Technetium Coupled to Biologically Active Molecules
It has been demonstrated (Wald et al. 2001) that the cyclopentadienyl ligand can be coordinated to [99mTc(OH2)3(CO)3]+ in water by introducing the electron withdrawing acetyl group in cyclopentadiene to give acetyl-cp. Technetium(I) chemistry initiated by (Alberto et al. 2001) is greatly facilitated by the available Tc(I)-tricarbonyl synthon. Recent developments and investigations are presented in Sect. 2.2.
2.3.4 Search for Novel Tc Pharmaceuticals Peptides. Peptides with low molecular weight consisting of 5±15 amino acids have attracted much attention in radiopharmaceutical design because of their low immunogenicity, suitable pharmacokinetic properties, and high binding affinities. They are easier to synthesize and to modify than are larger molecules (Signore 1995). To be suitable as a tumor-imaging peptide, the density of the peptide affine receptor on tumors must be considerably higher than in other regions of the body. The metabolic stability and affinity for the receptor should be high. Many excellent reviews have been published discussing different aspects of technetium radiopharmaceuticals based on peptides (Aloj and Morelli 2004; Eberle et al. 2004; Fichna and Janecka 2003; Giblin et al. 2005; Langer and Beck-Sickinger 2001; Liu 1999; Liu and Edwards 2002; Maecke 2005; Okarvi 2004; Signore et al. 2001). Naturally occurring peptides that can be used for tumor imaging are listed in Table 2.3.1. Modified derivatives of somatostatine have been synthesized to prolong the biological half-life of native somatostatine. The most important derivative is octreotide (sandostatin), a cyclic peptide with 8 amino acids, unlike the 14 in somatostatine. The successful use of octreoscan in the diagnosis of somatostatine receptor-positive tumors has intensified the search for improved or new peptide-based agents for imaging thrombi, infection/inflammation, and different tumors. Among the chelate units used for peptide labeling, the Tc-HYNIC and Tc-tricarbonyl cores have gained importance. A freeze-dried kit formulation for the preparation of 99m Tc-EDDA-HYNIC-D-Phe(1), Tyr(3)-octreotide, another somatostatin analog for tumor diagnosis, has recently been published (von Guggenberg et al. 2004). Ongoing research on 99mTc-HYNIC somatostatin analogs has further clarified the effect of labeling methods and peptide sequence on bioperformance (Bangard et al. 2000; Decristoforo and Mather 1999 a, b; Decristoforo et al. 2000). A variety of coligands used for labeling HYNIC-derivatized peptides has been explored, e.g., 2-mercaptopyridines and 2-mercaptopyrimidines (Babich et al. 2001). Recently described labeled HYNIC-conjugated peptides also involve RGD (Arg-GlyAsp) peptides targeting the integrin avb3 (vitronectin) receptor. Tertiary ligand complexes of HYNIC-conjugated peptide, tricine and trisodium triphenylphosphine-3,3',3''trisulfonate (TPPTS) have been published (Liu et al. 2001; Su et al. 2002). Interleukin-8, a chemotactic cytokine involved in activation of neutrophils to areas of infection, can be labeled with 99mTc-HYNIC with preservation of its leukocyte receptor-binding capacity (Rennen et al. 2001). After the introduction of the Tc(I) tricarbonyl approach, its application to peptide labeling has been pursued (Egli et al. 1999). Other chelating frameworks have been studied such as the novel dithia-bisphosphine chelator (Gali et al. 2001), or further employed such as tripeptide N3S chelators for the
Chapter 2 Technetium in Medicine Table 2.3.1. List of naturally occurring peptides that can be used for tumor imaging Ligand
Selectivity
Somatostatine Derivatives Alpha-MSH LHRH VIP/PACAP RGD CCK-B/gastrine Neutrotensin Bombesin/GRP Substance P
Neuroendocrinic tumors, non±Hodgkin's lymphoma, Melanomas, breast tumors Melanomas Prostata tumors, breast tumors SCLC, tumors of colon, stomach, pancreas Blood vessels of tumors MTC, SCLC, pancreas tumors, astrocytomes SCLC, colon tumors, exocrinic pancreas tumors SCLC, colon tumors, glioblastomas, prostata tumors Glioblastomas, astrocytomas, MTC, breast tumors, Peritoneal blood vessels
SCLC small cell lung carcinoma, MTC medullary thyroid cancer
Fig. 2.3.9. Structure of Tc-labeled depreotide (NeoTectTM)
inflammation imaging agent 99mTc-RP128 (Caveliers et al. 2001), a tuftsin receptorbinding peptide (Wong et al. 2001) and melanocortin receptor-1 specific ligands for targeting melanoma (Sharma et al. 2000). The commercial kit NeoTectTM (Diatide) was designed as a radiopharmaceutical for somatostatin-receptor imaging of lung tumors (Virgolini et al. 1998). It is based on the peptide P829 (depreotide), a structural modification of octreotide, with the technetium binding N3S sequence diaminopropionic acid-lysine-cysteine built into the molecule (Cyr et al. 1999) (Fig. 2.3.9). This modification is an alternative to octreotide, where the labeling process leads to the reduction of the disulfide bond, resulting in a loss of receptor-binding affinity (Blum et al. 1999; Vallabhajosula et al. 1996). Novel 99mTc-based tetra-amine-functionalized [Tyr3]octreotate analogues (Fig. 2.3.10) have been developed for imaging of somatostatin receptor-positive tumors (Maina et al. 2002; Nikolopoulou et al. 2006). An intrapatient comparison of 99mTc-N4-[Tyr3]octreotate with 99mTc-EDDA/HYNIC[Tyr3]octreotide showed that 99mTc-Demotate is a promising agent for somatostatin receptor scintigraphy (Gabriel et al. 2004). The same open-chain tetra-amine ligand has been conjugated to various bombesin derivatives. First studies in mice showed high and specific accumulation of 99mTc-De-
47
48
2.3 Technetium Coupled to Biologically Active Molecules
Fig. 2.3.10. Structure of tetra-amine-functionalized
99m
Tc-Demotate
Fig. 2.3.11. Hybrid distamycin-cysteine conjugated with a [99mTc(N)(PP)]2+ fragment
mobesin 1 in gastrin releasing peptide receptor (GRP-R)-positive regions (pancreas, gastrointestinal tract) (Nock 2003). A new high-affinity technetium-99m-bombesin analogue with low abdominal accumulation has been recently published (Lin et al. 2005). 99m Tc-UBI 29-41, a technetium-99m-labeled peptide derived from ubiquicidine, targets bacterial and fungal infections in experimental animals. Welling et al. reported on the radiochemical and biological features of this radioactive agent and the importance of the amino acid sequence of UBI 29-41 for imaging of infections (Lupetti et al. 2002; Welling et al. 2002, 2005). An attempt to exploit the chemistry of nitridotechnetium(V) complexes for labeling small biomolecules has been described (Baraldi et al. 2000). The tripyrrole peptide distamycin A, an antibiotic agent that binds to DNA, was functionalized with cysteine to obtain a bidentate ligand, which forms a mixed-ligand complex with a [99mTc(N)(PP)]2+ fragment (Fig. 2.3.11). Proteins and Antibodies. In the past, considerable work has been focused on the development of 99mTc-labeled monoclonal antibodies and their fragments. Three main strategies for labeling can be distinguished: direct labeling, bifunctional chelating agent (BFCA)-based prelabeling, and BFCA-based postlabeling. Among the direct labeling methods, reduction of the antibody by a thiol reagent, such as mercaptoethanol or dithiothreitol, results in high labeling yields (Reilly 1993; Schwarz et al. 1988; Thakur et al. 1991). Table 2.3.2 compiles 99mTc-labeled antibodies approved as radiopharmaceuticals in the United States and the European Union.
Chapter 2 Technetium in Medicine Table 2.3.2.
99m
Tc-labeled antibodies approved as radiopharmaceutical (2005)
Drug
Indication
Antibody
Target
99m
Neutrospec
Equivocal signs and appendicitis (infection/ inflammation) Colorectal cancer Osteomyelitis (infection/ inflammation in bone) Colorectal cancer
Fanolesomab (IgM, murine)
CD15
Reduced protein
2004 (US)
Votumumab (IgG, human) Sulesomab (Fab', murine)
CTAA16.88
Reduced protein Reduced protein
1998 (EU)
Arcitumomab (Fab', murine)
CEA
Reduced protein
Small cell lung cancer Melanoma
Nofetumomab CD20 (Fab', murine) Antimelanoma HMW-MAA mAb fragments (Fab' and F(ab')2, murine)
1996 (US); 1996, withdrawn 2005 (EU) 1996 (US)
Humaspect Leukoscan
CEA-Scan
Verluma TecnemabK-1
CEA and NCA90
Tc-binding Year of approval
N2S2 chelate Reduced protein
1997 (EU)
1996, withdrawn 2000 (EU)
Sources: pharmacos.eudra.org; www.fda.gov; www.biopharma.com CEA carcinoembryonic antigen, CD cluster of differentiation, mAb monoclonal antibody, CTAA cytokeratine tumor-associated complex of antigens, NCA granulocyte nonspecific crossreacting antigen, HMW-MAA high-molecular-weight melanoma-associated antigen Table 2.3.3.
99m
Tc-labeled monoclonal antibodies and antibody fragments for potential application
Antigen
Potential imaging application
99m
CA125 CD4
Ovarian cancer Rheumatoid arthritis
Direct labeling Direct labeling
CD22 CD44v6
Non±Hodgkin's lymphoma Head and neck squamous cell carcinoma Infection/inflammation
MAG3 MAG3 Direct labeling
EGFR-expressing tumors
EC, direct labeling
G250
Renal cell carcinoma
MUC1 Myosin
Bladder cancer, breast cancer Myocardial infraction
HYNIC, MAG3, direct labeling Tricarbonyl, direct labeling Direct labeling
P185HER-2 TAG-72
Breast cancer Adenocarcinomas
CD62E (E-Selectin) EGFR
Tc-binding method
Tricarbonyl HYNIC, introduced SH-group
References Kobayashi et al. 1993 Kinne et al. 1995; Becker et al. 1990 Postema et al. 2003 Stroomer et al. 2000; Colnot et al. 2003 Jamar et al. 2002 Schechter et al. 2003; Meenakshi et al. 2003 Steffens et al. 1999 Waibel et al. 1999; Simms et al. 2001 Iwasaki et al. 2001; Taillefer et al. 1995 Willuda et al. 2001 Goel et al. 2001; Ranadive et al. 1993
CA cancer antigen, CD cluster of differentiation, MUC mucin, TAG tumor-associated glycoprotein, EGFR epidermal growth factor receptor, MAG3 mercaptoacetyltriglycine, EC ethylcysteinate, HYNIC hydrazino nicotinamide
49
50
2.3 Technetium Coupled to Biologically Active Molecules Table 2.3.4.
99m
Tc-labeled proteins (excluding antibodies)
Protein
Imaging application
99m
Polyclonal IgG
Infection/inflammation, Blood pool
HYNIC, direct labeling
HSA
Blood pool
Annexin V
Apoptotic cells
Interleukins
Infection/inflammation
HYNIC, MAG3, direct labeling N2S2, HYNIC, MAG3, EC, tricarbonyl, endogenous peptide sequences, direct labeling HYNIC, N3S-chelate
NGA GSA Aprotinin
Liver disease Liver disease Amyloidosis
Direct labeling DTPA Direct labeling
FGF-1 EGF
FGF-1 receptor EGF-receptor expressing tumors Infection
HYNIC Introduced thiol group (direct labeling) HYNIC
Infection Infection Infection Target with a docking tag
HYNIC Direct labeling Direct labeling HYNIC
Anaphylatoxin C5a, C5adR NAP-2 (CXCL-7) Ubiquicidin Lactoferrin HuS (adapter protein)
Tc-binding unit
References Abrams et al. 1990; Pieri et al. 1991; Claessens et al. 1996; Dams et al. 2000 Verbeke et al. 1995; Pieri et al. 1991 Lahorte et al. 2004; Boersma et al. 2005 Rennen et al. 2001, 2003a; Signore et al. 2004; Chianelli et al. 1997 Stadalnik et al. 2001 Kokudo et al. 2003 Schaadt et al. 2003; Aprile et al. 1995 Zinn et al. 2000 Capala et al. 1997 Rennen et al. 2003 b Rennen et al. 2004 Welling et al. 2000 Welling et al. 2000 Blankenberg et al. 2004
IgG immunoglobulin G, HSA human serum albumin, NGA galactosyl neoglycoalbumin, GSA galactosyl human serum albumin, FGF-1 acidic fibroblast growth factor, EGF epidermal growth factor, NAP neutrophil-activating peptide, HuS 110±amino acid fragment of human ribonuclease I, MAG3 mercaptoacetyltriglycine, HYNIC hydrazino nicotinamide, EC ethylcysteinate, DTPA diethylene triamine pentaacetate
Some further examples for current search in antibody labeling are given by Tang et al. (2005), Francis et al. (2004), and Jeong et al. (2004). 99m Tc-labeled antibodies in experimental evaluation are summarized in Table 2.3.3. A simple liquid formulation for the preparation of 99mTc-HYNIC-annexin V has been developed. Biodistribution studies in mice indicated that the target organs were the kidneys (Vanderheyden et al. 2002). 99m Tc-HYNIC annexin V conjugates have been used for detection of apoptotic tumor response in vivo after a single dose of chemotherapy (Mochizuki et al. 2003), and for the evaluation of inflammation and apoptosis in rats with autoimmune myocarditis (Tokita 2003). A selection of 99mTc-labeled proteins (excluding antibodies) is summarized in Table 2.3.4.
Chapter 2 Technetium in Medicine
Oligonucleotides. Small oligonucleotide sequences that are complementary to a small mRNA segment could potentially target any specific mRNA molecule, and be used to image endogenous gene expression at the transcription level (Duatti 2004; Younes et al. 2002). Low in vivo stability continues to be a serious drawback. However, modifications may increase resistance to nucleases (Borkowski and Dinkelborg 2006; Usman and Blatt 2000). Several authors reported the use of a so-called morpholino (MORF), a commercially available synthetic oligomer for pretargeting application (Liu et al. 2002, 2004). A construct of MAG3 and cMORF was found to be effective in a mouse tumor model. Biodistribution data indicated high uptake in the tumor and low uptake in the normal tissues (Liu et al. 2002). Recently, Qin et al. (2005) reported on molecular imaging of atherosclerotic plaques with 99mTc-labeled antisense oligonucleotides. A review on recent progress in antisense targeting with radiolabeled DNA derivatives was given by Hnatowich and Nakamura (2004). Central Nervous System (CNS) Receptor Imaging Agents. The development of Tc-based imaging agents selective for CNS receptors has been an area of considerable research endeavor. Progress has been made in the development of a dopamine transporter (DAT) imaging agent 99mTc-TRODAT-1 (Kung et al 1997) (Fig. 2.3.12), the development of another DAT ligand, 99mTc-O(15)O5T (Callahan et al. 2001), and synthesis of 99mTc complexes with nanomolar in vitro affinity for dopamine (D1, D2), serotonin (5-HT1A, 5-HT2A) and muscarinic acetylcholine receptors. The state-of-the-art of technetium-based CNS receptor ligands have been recently reviewed (Johannsen and Pietzsch 2002 a). Molecular recognition of technetium complexes and their fit into the receptor-binding pocket is achievable. This is indicated by the high in vitro affinities of manifold Tc complexes to the serotonin-5-HT1A receptor in the nanomolar and subnanomolar range (Alberto et al. 1999; Bernard et al. 2003; Bolzati et al. 2003; Boschi et al. 2003; Drews et al. 2002; Heimbold et al. 2002 a, b; Kara 2004; Leon et al. 2002; Papagianopoulou et al. 2002; Saidi et al. 2004; Samnick et al. 2004) (Fig. 2.3.13). Therefore, receptor binding would be high if the ligand would also demonstrate high uptake in brain; however, very low or absent brain uptake is the main issue in the development of receptor-binding imaging agents. A suitable combination of a high receptor affinity with a sufficient brain uptake was achieved only with the DAT ligands. 99m
Fig. 2.3.12. Dopamine transporter (DAT) imaging agent
99m
Tc-TRODAT-1
51
52
2.3 Technetium Coupled to Biologically Active Molecules
Fig. 2.3.13. 99mTc receptor ligands with nanomolar and subnanomolar affinities for the 5-HT1A receptor (in vitro)
References Abrams MJ, Juweid M, tenKate CI et al (1990) Technetium-99m-human polyclonal IgG radiolabelled via the hydrazino nicotinamide derivative for imaging focal sites of infection in rats. J Nucl Med 31:2022±2028 Alberto R, Schibli R, Schubiger PA et al (1999) First application of fac-[99mTc(OH2)3(CO)3]+ in bioorganometallic chemistry: design, structure, and in vitro affinity of a 5-HT1A receptor ligand labelled with 99mTc. J Am Chem Soc 121:6076±6077 Alberto R, Ortner K, WheatleyN, Schibli R, Schubiger PA (2001) Synthesis and properties of boranocarbonate: a convenient in situ CO source for the aqueous preparation of [99mTc(OH2)3(CO)3]+. J Am Chem Soc 123:3135±3136 Aloj L, Morelli G (2004) Design, synthesis and preclinical evaluation of radiolabeled peptides for diagnosis and therapy. Curr Pharm Design 10:3009±3031 Aprile C, Marinone G, Saponaro R et al (1995) Cardiac and pleuropulmonary AL amyloid imaging with technetium-99m labelled aprotinin. Eur J Nucl Med 22:1393±1401 Babich JW, Coco WG, Barrow S et al (2000) 99mTc-labelled chemotactic peptides: influence of coligand on distibution of molecular species and infection imaging properties. Synthesis and structural characterization of model complexes with the [Re(g2±HNNC5H4N)(g1±NNC5H4N)] core. Inorg Chim Acta 309:123±136 Babich JW, Graham W, Femia FJ et al (2001) 6-Mercaptomethylpyridine-3-carboxylic acid (MEMNIC): a new reagent for peptide labelling with Tc-99m. Inorg Chim Acta 323:23±36 Ballinger JR (2002) The influence of carrier on 99mTc radiopharmaceuticals. Q J Nucl Med 46: 224± 232
Chapter 2 Technetium in Medicine Bangard M, Behe M, Guhlke S et al (2000) Detection of somastotatin receptor-positive tumors using the new 99mTc-tricine-HYNIC-d-Phe1-Tyr3-octreotide: first results in patients and comparison with 111In-DTPA-d-Phe1-octreotide. Eur J Nucl Med 27:628±637 Baraldi PG, Romagnoli R, Duatti A et al (2000) Synthesis of hybrid distamycin-cysteine labelled with 99m Tc: a model for a novel class of cancer imaging agents. Bioorg Med Chem Lett 10:1397±1400 Becker W, Emmrich F, Horneff G et al (1990) Imaging rheumatoid arthritis specifically with technetium 99m CD4-specific (T-helper lymphocytes) antibodies. Eur J Nucl Med 17:156±159 Bernard J, Ortner K, Spingler B et al (2003) Aqueous synthesis of derivatized cyclopentadienyl complexes of technetium and rhenium directed toward radiopharmaceutical application. Inorg Chem 42:1014±1022 Blankenberg FG, Mandl S, Cao YA et al (2004) Tumor imaging using a standardized radiolabelled adapter protein docked to vascular endothelial growth factor. J Nucl Med 45:1373±1380 Blum JE, Handmaker H, Rinne NA (1999) The utility of a somatostatin-type receptor binding peptide radiopharmaceutical (P829) in the evaluation of solitary pulmonary nodules. Chest 115:224±232 Boersma HH, Kietselaer BLJH, Stolk LML et al (2005) Past, present, and future of annexin A5: from protein discovery to clinical applications. J Nucl Med 46:2035±2050 Bolzati C, Boschi A, Duatti A et al (2000) Geometrically controlled selective formation of nitrido technetium(V) asymmetrical heterocomplexes with bidentate ligands. J Am Chem Soc 122:4510±4511 Bolzati C, Boschi A, Uccelli L et al (2002) Chemistry of the strong electrophilic metal fragment [99mTc(N)(PXP)]2+ (PXP = diphosphine ligand). A novel tool for the selective labelling of small molecules. J Am Chem Soc 124:11468±11479 Bolzati C, Mahmood A, Malago E et al (2003) The [Tc-99m(N)(PNP)]2+ metal fragment: a technetium-nitrido synthon for use with biologically active molecules the N-(2-methoxyphenyl)piperazyl-cysteine analogues as examples. Bioconjug Chem 14:1231±1242 Bolzati C, Benini E, Cazzola E et al (2004) Synthesis, characterization, and biological evaluation of neutral nitrido technetium(V) mixed ligand complexes containing dithiolates and aminodiphosphines. A novel system for linking technetium to biomolecules Bioconjug Chem 15:628±637 Borkowski S, Dinkelborg L (2006) Aptamers for in vivo imaging. In: Klussmann S (ed) The aptamer handbook. Wiley, Weinheim Boschi A, Bolzati C, Benini E et al (2001) A novel approach to the high-specific-activity labelling of small peptides with the technetium-99m fragment [99mTc(N)(PXP)]2+ (PXP = diphosphine ligand). Bioconjug Chem 12:1035±1042 Boschi A, Uccelli L, Duatti A et al (2003) Asymmetrical nitrido Tc-99m heterocomplexes as potential imaging agents for benzodiazepine receptors. Bioconjug Chem 14:1279±1288 Boschi A, Duatti A, Uccelli L (2005) Development of technetium-99m and rhenium-188 radiopharmaceuticals containing a terminal metal-nitrido multiple bond for diagnosis and therapy. Top Curr Chem 252:85±115 Callahan RJ, Dragotakes SC, Barrow SA et al (2001) A phase I clinical trial of the DAT ligand Tc99m-O(15)O5T. J Nucl Med 42(Suppl):1125 Capala J, Barth RF, Bailey MQ et al (1997) Radiolabelling of epidermal growth factor with 99mTc and in vivo localization following intracerebral injection into normal and glioma-bearing rats. Bioconjug Chem 8:289±295 Caveliers V, Goodbody AE, Tran LL et al (2001) Evaluation of Tc-99m-RP128 as a potential inflammation imaging agent: human dosimetry and first clinical results. J Nucl Med 2001 42:154±161 Cesati RR, Tamagnan G, Baldwin RM et al (2002) Synthesis of cyclopentadienyltricarbonyl rhenium phenyltropanes by double ligand transfer: organometallic ligands for the dopamine transporter. Bioconjug Chem 13:29±39 Chianelli M, Signore A, Fritzberg AR et al (1997) The development of technetium-99m-labelled interleukin-2: a new radiopharmaceutical for the in vivo detection of mononuclear cell infiltrates in immune-mediated diseases. Nucl Med Biol 24:579±586 Claessens RAMJ, Boerman OC, Koenders EB et al (1996) Technetium-99m labelled hydrazinonicotinamido human non-specific polyclonal immunoglobulin G for detection of infectious foci: a comparison with two other technetium-labelled immunoglobulin preparations. Eur J Nucl Med 23:414±421 Colnot DR, Roos JC, de Bree R et al (2003) Safety, biodistribution, pharmacokinetics, and immunogenicity of 99mTc-labeled humanized monoclonal antibody BIWA 4 (bivatuzumab) in patients with squamous cell carcinoma of the head and the neck. Cancer Immunol Immunother 52:576± 582
53
54
2.3 Technetium Coupled to Biologically Active Molecules Cyr JE, Pearson DA, Manchanda R et al (1999) Characterization and radiolabelling chemistry of Tc99m depreotide: a somatostatin receptor binding tumor imaging agent. J Nucl Med 40(Suppl):321 Dams ETM, Nijhof MW, Boerman OC et al (2000) Scintigraphic evaluation of experimental chronic osteomyelitis. J Nucl Med 41:896±902 Decristoforo C, Mather SJ (1999 a) 99m-Technetium-labelled peptide-HYNIC conjugates: effects of lipophilicity and stability on biodistribution. Nucl Med Biol 26:389±396 Decristoforo C, Mather SJ (1999 b) Technetium-99m somatostatin analogues: effect of labelling methods and peptide sequence. Eur J Nucl Med 26:869±876 Decristoforo C, Melendez-Alafort L, Sosabowski JK et al (2000) 99mTc-HYNIC-[Tyr3]-octreotide for imaging somastotatin-receptor-positive tumors: preclinical evaluation and comparison with 111 In-octreotide. J Nucl Med 41:1114±1119 Drews A, Pietzsch HJ, Syhre R et al (2002) Synthesis and biological evaluation of technetium(III) mixed-ligand complexes with high affinity for the cerebral 5-HT1A receptor and the alpha1adrenergic receptor. Nucl Med Biol 29:389±398 Duatti A (2004) In vivo Imaging of oligonucleotides with nuclear tomography. Curr Drug Targets 5:753±760 Eberle AN, Mild G, Froidevaux S (2004) Receptor-mediated tumor targeting with radiopeptides. Part 1. General concepts and methods: applications to somatostatin receptor-expressing tumors. J Rec Sig Trans 24:319±455 Edwards DS, Liu S, Harris AR et al (1999 a) 99mTc-labelling of hydrazones of a hydrazinonicotinamide conjugated cyclic peptide. Bioconjug Chem 10:803±807 Edwards DS, Liu S, Ziegler MC et al (1999 b) RP463: a stabilized technetium-99m complex of a hydrazinonicotinamide-derivatized chemotactic peptide for infection imaging. Bioconjug Chem 10:884±891 Egli A, Alberto R, Tannahill L et al (1999) Organometallic 99mTc-aquaion labels peptide to an unprecedented high specific activity. J Nucl Med 40:1913±1917 Fichna J, Janecka A (2003) Synthesis of target-specific radiolabelled peptides for diagnostic imaging. Bioconjug Chem 14:3±17 Francis RJ, Mather SJ, Chester K et al (2004) Radiolabelling of glycosylated MFE-23 CPG2 fusion protein (MFECP1) with Tc-99m for quantitation of tumour antibody-enzyme localisation in antibody-directed enzyme pro-drug therapy (ADEPT). Eur J Nucl Med Mol Imaging 31:1090± 1096 Gabriel M, Decristoforo C, Maina T et al (2004) 99mTc-N4-[Tyr3]octreotate versus 99mTc-EDDA/ HYNIC-[Tyr3]octreotide: an intrapatient comparison of two novel technetium-99m labelled tracers for somatostatin receptor scintigraphy. Cancer Biother Radiopharm 19:73±79 Gali H, Hoffman TJ, Sieckman GL et al (2001) Synthesis, characterization, and labelling with Tc99m/Re-188 of peptide conjugates containing a dithia-bisphosphine chelating agent. Bioconjug Chem 12:354±363 Giblin MF, Veerendra B, Smith CJ (2005) Radiometallation of receptor-specific peptides for diagnosis and treatment of human cancer. In Vivo 19:9±30 Goel A, Baranowska-Kortylewicz J, Hinrichs SH et al (2001) 99mTc-labelled divalent and tetravalent CC49 single-chain fv's: novel imaging agents for rapid in vivo localization of human colon carcinoma. J Nucl Med 42:1519±1527 Guggenberg von E, Mikolajczak R, Janota B et al (2004) Radiopharmaceutical development of a freeze-dried kit formulation for the preparation of [Tc-99m-EDDA-HYNIC-D-Phe(1),Tyr(3)]-octreotide, a somatostatin analog for tumor diagnosis. J Pharm Sciences 93:2497±2506 Harris TD, Sworin M, Williams N et al (1999) Synthesis of stable hydrazones of a hydrazinonicotinylmodified peptide for the preparation of 99mTc-labelled radiopharmaceuticals. Bioconjug Chem 10:808 Heimbold I, Drews A, Syhre R et al (2002 a) A novel technetium-99m radioligand for the 5-HT1A receptor derived from desmethyl-WAY-100635 (DWAY). Eur J Nucl Med 29:82±87 Heimbold I, Drews A, Kretzschmar M et al (2002 b) Synthesis, biological and autoradiographic evaluation of a novel Tc-99m radioligand derived from WAY 100635 with high affinity for the 5-HT1A receptor and the alpha1-adrenergic receptor. Nucl Med Biol 29:375±387 Hnatowich DJ, Nakamura K (2004) Antisense targeting in cell culture with radiolabelled DNAs ± a brief review of recent progress. Ann of Nucl Med 18:363±368 Hom RK, Katzenellenbogen JA (1997) Technetium-99m-labelled receptor-specific small-molecule radiopharmaceuticals: recent developments and encouraging results. Nucl Med Biol 24:485±498 Iwasaki T, Iwasaki I, Aihara Y et al (2001) Immunoscintigraphy of aortic dissection with 99mTc-labelled murine anti-smooth muscle myosin monoclonal antibody in rats. J Nucl Med 42:130±137
Chapter 2 Technetium in Medicine Jamar F, Houssiau FA, Devogelaer JP et al (2002) Scintigraphy using a technetium 99m-labelled anti-E-selectin Fab fragment in rheumatoid arthritis. Rheumatology 41:53±61 Jeong JM, Hong MK, Lee J et al (2004) Tc-99m-neolactosylated human serum albumin for imaging the hepatic asialoglycoprotein receptor. Bioconjug Chem 15:850±855 Johannsen B, Pietzsch HJ (2002a) Development of technetium-99m-based CNS receptor ligands: have there been any advances? Eur J Nucl Med Mol Imaging 29:263 Johannsen B, Pietzsch H-J (2002b) Bioactivity of small technetium complexes In: Nicolini M., Mazzi U (eds) Technetium, rhenium and other metals in chemistry and nuclear medicine. SG Editoriali, Padova, Italy, pp 273±283 Jurisson SS, Lydon JD (1999) Potential technetium small molecule radiopharmaceuticals. Chem Rev 99:2205±2218 Kara G (2004) A novel mechanism for guanidino succinic acid (GSA) and technetium-99m-GSA, a novel agent for muscarinic acetylcholine receptor imaging. Eur J Nucl Med Mol Imaging 31(Suppl): 359±359 Kinne RW, Becker W, Koscheck T et al (1995) Rat adjuvant arthritis: imaging with technetium99m-anti-CD4 fab fragments. J Nucl Med 36:2268±2275 Kobayashi H, Sakahara H, Saga T et al (1993) A human/mouse chimeric monoclonal antibody against CA125 for radioimmunoimaging of ovarian cancer. Cancer Immunol Immunother 37:143±149 Kokudo N, Vera DR, Makuuchi M (2003) Clinical application of TcGSA. Nucl Med Biol 30:845±849 Kung MP, Stevenson DA, Plæssl K et al (1997) [Tc-99m]TRODAT-1: a novel technetium-99m complex as a dopamine transporter imaging agent. Eur J Nucl Med 24:372±380 Kushner SA, McElgin WT, Kung MP et al (1999) Kinetic modeling of [Tc-99m]TRODAT-1: a dopamine transporter imaging agent. J Nucl Med 40:150±158 Lahorte CMM, Vanderheyden JL, Steinmetz N et al (2004) Apoptosis-detecting radioligands: current state of the art and future perspectives. Eur J Nucl Med 31:887±919 Langer M, Beck-Sickinger AG (2001) Peptides as carrier for tumor diagnosis and treatment. Curr Med Chem Anticancer Agents 1:71±93 Le Bideau F, Salmain M, Top S et al (2001) New and efficient routes to biomolecules substituted with cyclopentadienyltricarbonylrhenium and -technetium derivatives. Chem Eur J 7:2289±2294 Leon A, Rey A, Mallo L et al (2002) Novel mixed ligand technetium complexes as 5-HT1A receptor imaging agents. Nucl Med Biol 29:217±226 Lin KS, Luu A, Baidoo KE et al (2005) A new high affinity technetium-99m-bombesin analogue with low abdominal accumulation. Bioconjug Chem 16:43±50 Liu G, Mangera K, Liu N et al (2002) Tumor pretargeting in mice using 99mTc-labelled morpholino, a DNA analog. J Nucl Med 43:384±391 Liu GZ, He J, Dou SP et al (2004) Pretargeting in tumored mice with radiolabeled morpholino oligomer showing low kidney uptake. Eur J Nucl Med Mol Imaging 31:417±424 Liu S, Edwards DS (1999) Tc-99m-labelled small peptides as diagnostic radiopharmaceuticals. Chem Rev 99:2235±2268 Liu S, Edwards DS, Ziegler MC et al (2001) Tc-99m-Labelling of a hydrazinonicotinamide-conjugated vitronectin receptor antagonist useful for imaging tumors. Bioconjug Chem 12:624±629 Liu S, Edwards DS (2002) Fundamentals of receptor-based diagnostic metalloradiopharmaceuticals. In: Topics in current chemistry: contrast agents II, optical, ultrasound, x-ray and radiopharmaceutical imaging. Springer, Berlin Heidelberg New York, pp 259±278 Lupetti A, Welling MM, Mazzi U et al (2002) Technetium-99m labelled fluconazole and antimicrobial peptides for imaging of Candida albicans and Aspergillus fumigatus infections. Eur J Nucl Med Mol Imaging 29:674±679 Maecke HR (2005) Radiolabelled peptides in nuclear oncology: influence of peptide structure and labelling strategy on pharmacology. Ernst Schering Res Found Workshop 49:43±79 Maina T, Nock B, Nikolopoulou A et al (2002) 99mTc-Demotate, a new 99mTc-based [Tyr3]octreotate analogue for the detection of somastotatin receptor-positive tumors: synthesis and preclinical results. Eur J Nucl Med 29:742±753 Meenakshi A, Ganesh V, Suresh Kumar R et al (2003) Radioimmuno targetting technetium-labeled anti-epidermal growth factor receptor monoclonal antibodies in experimental tumor models. Q J Nucl Med 47:139±144 Mochizuki T, Kuge Y, Zhao S et al (2003) Detection of apoptotic tumour response in vivo after a single dose of chemotherapy with 99mTc-annexin V. J Nucl Med 44:92±97 Mu M, Kung MP, Plæssl K et al (1999) Quantitation of Tc-TRODAT in human plasma samples by a simple extraction method. J Labelled Comp Radiopharm 42:213±215
55
56
2.3 Technetium Coupled to Biologically Active Molecules Mull ES, Sattigeri VJ, Rodriguez AL et al (2002) Aryl cyclopentadienyl tricarbonyl rhenium complexes: novel ligands for the estrogen receptor with potential use as estrogen radiopharmaceuticals. Bioorg Med Chem 10:1381±1398 Nikolopoulou A, Maina T, Sotiriou P et al (2006) Tetraamine-modified octreotide and octreotate: labelling with Tc-99m and preclinical comparison in AR4-2J cells and AR4-2J tumor-bearing mice. J Peptide Science 12:124±131 Nock BA, Maina T, Yannoukakos D et al (1999) Glutathione-mediated metabolism of technetium99m SNS/S mixed ligand complexes: a proposed mechanism of brain retention. J Med Chem 42:1066±1075 Nock B, Nikolopoulou A, Chiotellis E et al (2003) 99mTc-Demobesin 1, a novel potent bombesin analogue for GRP receptor-targeted tumour imaging. Eur J Nucl Med Mol Imaging 30:247±258 Okarvi SM (2004) Peptide-based radiopharmaceuticals: future tools for diagnostic imaging of cancers and other diseases. Med Res Rev 24:357±397 Ono M, Arano Y, Mukai T et al (2000) Control of radioactivity pharmacokinetics of 99mTc-HYNIClabelled polypeptides derivatized with ternary ligand complexes. Bioconjug Chem 13:491±501 Pak JK, Alberto R (2001) Coordination reactions of glucose derivatives with the [Tc(CO)3]+ moiety for radiopharmaceutical application. J Labelled Comp Radiopharm 44:498±500 Papagiannopoulou D, Pirmettis I, Tsoukalas C et al (2002) Oxotechnetium 99mTcO[SN(R)S][S] complexes as potential 5-HT1A receptor imaging agents. Nucl Med Biol 29:825±832 Pasqualini R, Comazzi V, Bellande E et al (1992) A new efficient method for the preparation of Tc99m-radiopharmaceuticals containing the TCN multiple bond. J Appl Radiat Isot 43:1329±1333 Pasqualini R, Duatti A, Bellande E et al (1994) Bis(dithiocarbamato)-nitrido Tc-99m-radiopharmaceuticals ± a class of neutral myocardial imaging agents. J Nucl Med 35:334±341 Pieri P, Fischman AJ, Ahmad M et al (1991) Cardiac blood-pool scintigraphy in rats and hamsters: comparison of five radiopharmaceuticals and three pinhole collimator apertures. J Nucl Med 32:851±855 Pietzsch HJ, Gupta A, Syhre R et al (2001 a) Mixed-ligand technetium(III) complexes with tetradentate/monodentate NS3/isocyanide coordination: a new nonpolar technetium chelate system for the design of neutral and lipophilic complexes stable in vivo. Bioconjug Chem 12:538±544 Pietzsch HJ, Tisato F, Refosco F et al (2001 b) Synthesis and characterization of novel trigonal bipyramidal technetium(III) mixed-ligand complexes with SES/S/P coordination (E= O, N(CH3), S). Inorg Chem 40:59±64 Pietzsch HJ, Seifert S, Syhre R et al (2003) Synthesis, characterization, and biological evaluation of technetium(III) complexes with tridentate/bidentate S,E,S/P,S coordination (E =O, N(CH3), S): a novel approach to robust technetium chelates suitable for linking the metal to biomolecules. Bioconjug Chem 14:136±143 Postema EJ, Raemaekers JMM, Oyen WJG et al (2003) Final results of the phase I radioimmunotherapy trial using 186Re-Epratuzumab for the treatment of patients with non±Hodgkin's lymphoma. Clin Cancer Res 9:3995s±4002s Qin GM, Zhang YX, Cao W et al(2005) Molecular imaging of atherosclerotic plaques with technetium-99m-labelled antisense oligonucleotides. Eur J Nucl Med Mol Imaging 32:6±14 Ranadive GN, Rosenzweig HS, Epperly MW et al (1993) A new method of technetium-99m labelling of monoclonal antibodies through sugar residues. A study with TAG-72 specific CC-49 antibody. Nucl Med Biol 20:719±726 Refosco F, Bolzati C, Duatti A et al (2000) Mixed ligand Tc- and Re-nitrido complexes for radiolabelling bioactive molecules. Recent Res Devel Inorganic Chem 2:89±98 Reilly RM (1993) Immunoscintigraphy of tumors using tc-99m-labelled monoclonal-antibodies ± a review. Nucl Med Commun 14:347±359 Rennen HJJM, Boerman OC, Oyen WJG et al (2001) Specific and rapid scintigraphic detection of infection with Tc-99m-labeled interleukin-8. J Nucl Med 42:117±123 Rennen HJJM, Boerman OC, Oyen WJG et al (2003 a) Kinetics of 99mTc-labelled interleukin-8 in experimental inflammation and infection. J Nucl Med 44:1502±1509 Rennen HJ, Oyen WJ, Cain SA et al (2003 b) Tc-99m-labelled C5a and C5a des Arg74 for infection imaging. Nucl Med Biol 30:267±272 Rennen HJJM, Frielink C, Brandt E et al (2004) Relationship between neutrophil-binding affinity and suitability for infection imaging: comparison of 99mTc-labelled NAP-2 (CXCL-7) and 3Cterminally truncated isoforms. J Nucl Med 45:1217±1223 Rose DJ, Maresca KP, Nicholson T et al (1998) Synthesis and characterization of organohydrazinocomplexes of technetium, rhenium and molybdenum with the {M(g1-HxNNR)(g2-HyNNR)} core and their relationship to radiolabelled organohydrazine-derivatized chemotactic peptides with diagnostic applications. Inorg Chem 37:2701±2716
Chapter 2 Technetium in Medicine Saidi M, Kothari K, Pillai MRA et al (2001) Cyclopentadienyl 99m-technetium tricarbonyl piperidin conjugate: biodistribution and imaging studies. J Labelled Cpd Radiopharm 44:603±618 Saidi M, Seifert S, Kretzschmar M et al (2004) Cyclopentadienyl tricarbonyl complexes of 99m-Tc for the in vivo imaging of the serotonin 5-HT1A receptor in the brain. J Organomet Chem 689:4739±4744 Samnick S, Scheuer C, Munks S et al (2004) Technetium-99m labelled 1-(4-fluorobenzyl)-4-(2-mercapto-2-methyl-4-azapentyl)-4-(2-mercapto-2-methylpropylamino)-pipe ridine and iodine-123 metaiodobenzylguanidine for studying cardiac adrenergic function: a comparison of the uptake characteristics in vascular smooth muscle cells and neonatal cardiac myocytes, and an investigation in rats. Nucl Med Biol 31:511±522 Schaadt BK, Hendel HW, Gimsing P et al (2003) 99mTc-aprotinin scintigraphy in amyloidosis. J Nucl Med 44:177±183 Schechter NR, Yang DJ, Azhdarinia et al (2003) Assessment of epidermal growth factor receptor with 99mTc-ethylenedicysteine-C225 monoclonal antibody. Anticancer Drugs 14:49±56 Schwarz A, Steinstrasser A, Bosslet K (1988) A simple procedure of Tc-99m labelling for monoclonal-antibodies. Eur J Nucl Med 14:C8±C8 Schwartz DA, Abrams MJ, Hauser MM et al (1991) Preparation of hydrazino-modified proteins and their use for the synthesis of Tc-99m-protein conjugates. Bioconjug Chem 2:333±336 Schwochau K (2000) Technetium chemistry and radiopharmaceutical applications. Wiley, New York Seifert S, Drews A, Gupta A et al (2000) Stability studies on 99m-technetium(III) complexes with tridentate/monodentate thiol ligands and phosphine (ª3+1+1º complexes). Appl Radiat Isot 53:431±438 Seifert S, Gupta A, Syhre R et al (2001) Ligand-exchange reaction of labile ª3+1º Tc-99m(V) complexes with SH group-containing proteins. Int J Appl Radiat Isot 54:637±644 Seifert S, Kçnstler JU, Schiller E (2004) Novel procedures for preparing 99mTc(III) complexes with tetradentate/monodentate coordination of varying lipophilicity and adaptation to 188Re analogues. Bioconjug Chem 15: 856±863 Sharma SD, Cai HZ, Yang W et al (2000) Melanocortin receptor-1 specific Tc-99m-metallopeptides for targeting melanoma. J Nucl Med 41:1021S Signore A (1995) Receptor ligands. Q J Nucl Med 39:83±85 Signore A, Annovazzi A, Chianelli M et al (2001) Peptide radiopharmaceuticals for diagnosis and therapy. Eur J Nucl Med 28:1555±1565 Signore A, Annovazzi A, Barone R et al (2004) 99mTc-interleukin-2 scintigraphy as a potential tool for evaluating tumor-infiltrating lymphocytes in melanoma lesions: a validation study. J Nucl Med 45:1647±1652 Simms MS, Perkins AC, Price MR et al (2001) 99mTechnetium-C595 radioimmunoscintigraphy: a potential staging tool for bladder cancer. BJU Int 88:686±691 Spies H, Pietzsch HJ, Johannsen B (1999) The ªn+1º mixed-ligand approach in the design of specific technetium radiopharmaceuticals: potentials and problems. In: Nicolini M, Mazzi U (eds) Tc, Re and other metals in chemistry and nuclear medicine, vol. 5. SG Editoriali, Padova, Italy, pp 101±108 Spradau TW, Edwards WB, Anderson CJ et al (1999) Synthesis and biological evaluation of Tc99m-cyclopentadienyltricarbonyltechnetium-labelled octreotide. J Nucl Med Biol 26:1±7 Stadalnik RC, Vera DR (2001) The evolution of 99mTc-NGA as a clinically useful receptor-binding radiopharmaceutical. Nucl Med Biol 28:499±503 Steffens MG, Oosterwijk E, Kranenborg MHGC et al (1999) In vivo and in vitro characterization of three 99mTc-labeled monoclonal antibody G250 preparations. J Nucl Med 40:829±836 Stroomer JWG, Roos JC, Sproll M et al (2000) Safety and biodistribution of 99mTechnetium-labeled anti-CD44v6 monoclonal antibody BIWA 1 in head and neck cancer patients. Clin Cancer Res 6:3046±3055 Su ZF, Liu G, Gupta S et al (2002) In vitro and in vivo evaluation of a technetium-99m-labelled cyclic RGD petide as a specific marker of avb3 integrin for tumor imaging. Bioconjug Chem 13:561±570 Syhre R, Seifert S, Spies H, et al (1998) Stability versus reactivity of ª3+1º mixed-ligand technetium-99m complexes in vitro and in vivo. Eur J Nucl Med 25:793±796 Taillefer R, Boucher L, Lambert R et al (1995) Technetium-99m antimyosin antibody (3±48) myocardial imaging: human biodistribution, safety and clinical results in detection of acute myocardial infarction. Eur J Nucl Med 22:453±464 Tait JF, Brown DS, Gibson DF et al (2000) Development and characterization of annexin V mutants with endogenous chelation sites for 99mTc. Bioconjug Chem 11:918±925
57
58
2.3 Technetium Coupled to Biologically Active Molecules Tait JF, Smith C, Gibson DF (2002) Development of annexin V mutants suitable for labelling with Tc(I)-carbonyl complex. Bioconjug Chem 13:1119±1123 Tang Y, Scollard D, Chen P et al (2005) Imaging of HER2/neu expression in BT-474 human breast cancer xenografts in athymic mice using [Tc-99m]-HYNIC-trastuzumab (Herceptin) Fab fragments. Nucl Med Commun 26:427±432 Thakur ML, DeFulvio J, Richard MD et al (1991) Tc-99m labelled monoclonal-antibodies ± evaluation of reducing agents. Nucl Med Biology 18:227±233 Tisato F, Refosco F, Porchia M, et al (2004) The crucial role of the diphosphine heteroatom X in the stereochemistry and stabilization of the substitution-inert [M(N)(PXP)](2+) metal fragments (M Tc, Re; PXP diphosphine ligand). Inorg Chem 43:8617±8625 Tokita N, Hasegawa S, Murayama K et al (2003) 99m-Tc-HYNIC-annexin V imaging to evaluate inflammation and apoptosis in rats with autoimmune myocarditis. Eur J Nucl Med Mol Imaging 30:232±238 Usman N, Blatt LRM (2000) Nuclease-resistant synthetic ribozymes: developing a new class of therapeutics. J Clin Invest 106:1197±1202 Vallabhajosula S, Moyer BR, Lister-James J et al (1996) Preclinical evaluation of technetium-99mlabelled somatostatin receptor-binding peptides. J Nucl Med 37:1016±1022 Vanderheyden JL, Verbeke K, Kieffer D et al (2002) Product development and formulation of 99mTc NYNIC-rh-annexin V. In: Nicolini M, Mazzi U (eds) Tc, Re and other metals in chemistry and nuclear medicine, vol. 6. SG Editoriali, Padova, Italy, pp 335±338 Verbeke K, Hjelstuen O, Debrock E et al (1995) Comparative evaluation of 99mTc-HYNIC-HSA and 99 m Tc -MAG3-HSA as possible blood pool agents. Nucl Med Comm 16:942±957 Virgolini I, Leimer M, Handmaker H et al (1998) Somatostatin receptor subtype specific and in vivo binding of a novel tumor tracer, 99mTc-P829. Cancer Res 58:1850±1859 Waibel R, Alberto R, Willuda J et al (1999) Stable one-step technetium-99m labelling of His-tagged recombinant proteins with a novel Tc(I)-carbonyl complex. Nature Biotechnol 17:897±901 Wald J, Alberto R, Ortner K et al (2001) Aqueous one-pot synthesis of derivatized cyclopentadienyl-tricarbonyl complexes of Tc-99m with an in situ CO source: application to a serotonergic receptor ligand. Angew Chem Int Ed 40:3062±3066 Welling MM, Paulusma-Annema A, Balter HS et al (2000) Technetium-99m labelled antimicrobial peptides discriminate between bacterial infections and sterile inflammation. Eur J Nucl Med 27:292±301 Welling MM, Mongera S, Lupetti A et al (2002) Radiochemical and biological characteristics of 99m Tc-UBI 29-41 for imaging of bacterial infections. Nucl Med Biol 29:413±422 Welling MM, Korsak A, Gorska B et al (2005) Kit with technetium-99m labelled antimicrobial peptide UBI 29-41 for specific infection detection. J Labelled Comp Radiopharm 48:683±691 Wenzel M, Klinge C (1994) Tc-99m-labelled estradiol derivatives ± synthesis, organ distribution and tumor affinity. J Labelled Cpd Radiopharm 34:981±987 Willuda J, Kubetzko S, Waibel R et al (2001) Tumor targeting of mono-, di-, and tetravalent antip185HER-2 miniantibodies multimerized by self-associating peptides. J Biol Chem 17:14385± 14392 Wong E, Bennett S, Lawrence B et al (2001) Tuftsin receptor-binding peptide labeled with technetium: chemistry and preliminary in vitro receptor-binding study. Inorg Chem 40:5695±5700 Younes CK, Boisgard R, Tavitian B (2002) Labelled oligonucleotides as radiopharmaceuticals: pitfalls, problems and perspectives. Curr Pharm Des 8:1451±1466 Zinn KR, Kelpke S, Chaudhuri TR et al (2000) Imaging Tc-99m-Labeled FGF-1 targeting in rats. Nucl Med Biol 27:407±414
Chapter 3
Stannous Chloride in the Preparation of 99mTc Pharmaceuticals
3
H. Spies and H.-J. Pietzsch
3.1 Introduction 99m
Tc pharmaceuticals need to be labeled by a simple procedure shortly before use. Because there is no effective chemistry available to attach a pertechnetate ion to an organic moiety, reduction of Tc(VII) in TcO±4 to a lower oxidation state is a prerequisite for 99mTc complex formation in high yield and purity. Experience with various ligands has shown that the oxidation state of technetium is affected by the nature of the reducing agent, the chelator, and the reaction conditions. The choice of a suitable reducing agent for one-step labeling at mild pH conditions has been a major research effort. Requirements of an ªidealº reducing agent for kit preparation: · Effective reduction at mild pH conditions · Formation of a single-component complex with distinct oxidation state · No interference with the complexation process · Not included in the final complex · Stable during storage of the kit (long shelf-life) Mild reaction conditions mean a neutral or weakly acidic pH, exclusion of toxic substances, and labeling at room temperature. Certain ligand systems favor distinct oxidation states; therefore, in kit formulations the nature and amount of reducing agent should be in balance with the ligand to ensure quantitative conversion of pertechnetate for complex formation, without further reduction to lower oxidation states. The reductant should not participate or interfere with the complexation process. Neither the reductant itself nor its oxidized form is part of the tracer molecule. Several reducing agents with a reduction potential below that of pertechnetate (+ 0.747 V, Schwochau 2000) are capable of reducing pertechnetate in aqueous solution. In the absence of an appropriate ligand, reduction proceeds to insoluble technetium(IV) oxide TcO2 ´ xH2O. In order to avoid colloid formation, reductions are generally carried out in the presence of a ligand that will stabilize a lower valence state of a technetium complex, thus limiting colloid formation (Srivastava and Richards 1983; Fig. 3.1). Labeling and, in particular pertechnetate reduction, have been the topic of a series of articles (Alvarez 1975; Clarke and Podbielski 1987; Eckelman and Steigman 1991; Noronha 1978; Novotnik 1990; Rhodes 1991; Srivastava et al. 1977; Steigman and Richards 1974). From the beginning of technetium-99m chemistry, a wide range of reducing agents have been used for pertechnetate, examples are given below (Srivastava and Richards 1983): · Ferric chloride and ascorbic acid has been used as a reducing mixture to prepare 99m Tc-labeled albumin (Persson and Liden 1969; Stern et al. 1965; Yokoyama et al. 1975). Ascorbate ion itself does not reduce technetium efficiently. However, ferric salt is reduced at acidic pH, generating ferrous ion, which upon elevation of pH can
60
3.1 Introduction
Fig. 3.1. Reduction and complex formation of pertechnetate
·
·
· ·
·
·
reduce pertechnetate; labeling of albumin occurred after adjustment to acidic pH. The reaction required strict control of the reaction conditions, several pH adjustments, and was therefore unsuitable for kit formulation. The use of borohydride (Deutsch et al. 1980; Smith et al. 1978) is presently limited to the synthesis of the fac-[99mTc(I)(H2O)3(CO)3]+ as a precursor for technetium(I)based radiopharmaceuticals (Alberto and Abram 2003). The typical feature of this reagent is production of an inhomogeneous mixture of various Tc species, even under well-controlled reaction conditions, including metallic technetium. Certain ligands, preferably those with phosphine (Deutsch et al. 1981; Vanderheyden et al. 1984) and thiol groups (Spies et al. 1978) also act as reductants. Although the reduction rate is low and an excess of ligand is required for quantitative yield, P and S ligands may have some advantages. Thus, water-soluble triphenylphosphine sulfonates suitably reduce disulfide bonds and pertechnetate simultaneously, which might offer advantages for direct labeling of peptides (Greenland et al. 2002). Hydrohalic acids (Hal = Cl, Br, I) (Thomas et al. 1979) are effective reducing agents for technetium, but their use requires harsh reaction conditions that lie outside the radiopharmaceutical milieu. Metallic reducing agents are convenient and efficient. Their disadvantage lies in the formation of colloids due to hydrolysis in aqueous solution, e.g., tin (II) and iron(II) (Lin et al. 1971), zinc metal (Kremer et al. 1989) or salts of titanium(III) (Kalincak et al. 1982), antimony(III) (Vilcek et al. 1982), molybdenum(III) (Vilcek et al. 1984), or tungsten(III) (Vilcek et al. 1985). Electrolytical reduction of 99mTc-pertechnetate has been investigated (Benjamin 1969, 1970; Dworkin and Gutkowski 1971; Eckelman et al. 1971 a; Gil et al. 1976). When using zirconium or tin electrodes, anodic dissolution of metal ions produced in situ reduction of pertechnetate (Steigman et al. 1974). Electrolysis has been used as a reliable method for laboratory production of 99mTc pharmaceuticals. Ferrous salt and tin(II) were identified as active reductants (Lin et al. 1971), producing labeling of human serum albumin (HSA) at pH 2.5. Ferrous salt needed pH elevation to increase its reduction potential (Zolle et al. 1975).
The advantages of stannous salts for kit formulation have been demonstrated (Eckelman and Richards 1970, 1972), and the stability of kits was increased by lyophilization (Deutsch and Redmond 1972), suggesting commercial production.
Chapter 3 Stannous Chloride in the Preparation of
99m
61
Tc Pharmaceuticals
3.2 Stannous Chloride: the Preferred Reducing Agent for Tc Pharmaceuticals The need for simple labeling methods for 99mTc pharmaceuticals had been expressed by scientists and physicians as early as 1965. The introduction of stannous ion as a reductant for kit preparation offered new perspectives in the development of 99mTc radiopharmaceuticals and attracted interest of all parties (Alvarez 1975; Eckelman et al. 1971b). Kits are a powerful tool in 99mTc chemistry, offering labeling in isotonic solution at room temperature simply by adding the 99mTc activity in a suitable volume. Stannous salts are nontoxic, and stable when lyophilized and kept in a nitrogen atmosphere. Stannous salts are a reliable reductant used in all kit formulations. Redox Chemistry. Tin forms compounds in the oxidation states + II and + IV. Potentials for the sequence Sn0 ? SnII ? SnIV in acidic and basic media are shown below (Wardell 1994): Acidic solution: Basic solution:
Sn0 ; 0:136 V Sn0 ; 0:91 V
SnII ; 0:15 V SnII
OH3 ; 0:93 V
SnIV SnIV
OH6 2
The feature that makes tin(II) so interesting for Tc pharmaceutical preparation is the ease of the stannous ion to be oxidized to tin(IV) according to the reaction Sn2 ! Sn4 2e There were many investigations to explain the mechanism of reduction. Since direct chemical measurements are out of question at carrier-free concentrations of 99mTc (10±9 M), carrier technetium (99Tc) in hydrochloric acid was used to determine the oxidation state of technetium in diethylene triamine pentaacetate (DTPA) and in citrate solution. Polarographic and iodometric techniques were used to analyze for unreacted stannous ion and to perform direct potentiometric titrations of pertechnetate-99 with stannous chloride (Mçnze 1980; Steigman et al. 1975). No quantitative kinetic studies had been made, but qualitative conclusions have been drawn for the reduction mechanism. Most probably, the first step is the reduction to Tc(V). Reduction to Tc(III) proceeds in two successive complementary reactions, both of which should be rapid in the low concentrations at radiopharmaceutical level: Tc
VII Sn
II ! Tc
V Sn
IV
1
Tc
V Sn
II ! Tc
III Sn
IV
2
Whether the reaction stops at the Tc(V) (reaction a) or Tc (III) (reaction b) oxidation state, or subsequent reactions occur, e.g., to Tc(IV), is dependent primarily on the nature of the ligand applied. Incidentally, the first established case of the existence of a Tc(V) compound in water came from a study of Tc(V) citrate (Steigman et al. 1975).
62
3.2 Stannous Chloride: the Preferred Reducing Agent for Tc Pharmaceuticals Table 3.1. Content of stannous chloride and calculated Sn-to-Tc ratios in selected commercially available cold kits Technetium kit
SnCl2 ´ 2H2O (mg)
Sn/Tc ratio a
MDP HSA microspheres B1 DMSA DTPA HIDA EC HSA microspheres B20 MIBI (Cardiolite) MAG3 Tetrofosmin (Myoview) ECD (Neurolite) HMPAO (Ceretec)
0.5 b 0.4 b 0.4 b 0.3 b 0.2 b 0.2 b 0.1 b 0.075 0.06 a 0.03 0.008 0.0076
1.2 ´ 105 9 ´ 104 9 ´ 104 7 ´ 104 5 ´ 104 5 ´ 104 2 ´ 104 1.7 ´ 104 1.4 ´ 104 7 ´ 103 2 ´ 103 2 ´ 103
MDP methylenediphosphonate, HSA human serum albumin, DMSA dimercaptosuccinic acid, DTPA diethylene triamine pentaacetate, HIDA hepatoiminodiacetic acid, EC ethylene dicysteine, HSA human serum albumin, MIBI monodentate methoxyisobutyl isocyanide, MAG3 mercaptoacetyltriglycine, ECD ethylene dicysteine dimer, HMPAO hexamethylpropylene amine oxime a 99m Tc eluate (370 MBq), 99Tc is not considered b Average of different kit formulations
Tin in the Labeling Process. Although stannous ion has become the reducing agent of choice, some inherent problems have to be considered: · Complicated solution chemistry of stannous compounds · Product contains Sn(IV) · Easily oxidized to Sn(IV) · Shelf-life Stannous compounds have a complicated solution chemistry. SnCl2´2H2O is very difficult to purify; the purest commercially available product contains at least 5% of Sn(IV) (Donaldson and Moser 1960). Stannous ion is readily oxidized by various oxidants, such as the oxygen in air. Oxidation proceeds already on standing, but is more critical in both the freeze-dried kit formulation, and in particular in solution during reconstitution because of the low Sn concentration (Table 3.1). A minimum concentration of stannous ion must be maintained to guarantee reduction during the shelf-life. First, the amount of stannous ion must ensure the Sn(II) capacity required for reduction of both 99m Tc and excess of long-lived 99Tc-pertechnetate present in generator eluates. Second, since the reduction potential of a solution of SnCl2 depends on the ratio of activities of Sn(IV) and Sn(II), the ratio of Sn(II) to Sn(IV) must not be too low. Oxygen and other oxidizing agents have to be carefully excluded from stannous chloride preparations. Due to oxidation on standing and side oxidation reactions, Sn(IV) is an unavoidable, relatively concentrated impurity in radiopharmaceutical preparations. The amount of stannous chloride is empirically optimized for each individual kit formulation, maintaining the balance between two parameters: A large excess of stannous chloride should be used with respect to the added pertechnetate activity and the amount of stannous chloride kept as low as possible in order to avoid further reduction of pertechnetate to a lower oxidation state. In addition, the level of tin(IV) impurity in the radiopharmaceutical should be kept as low as possible. The calculated optimal content of stannous chloride in a series of commercial kits is shown in Table 3.1, where
Chapter 3 Stannous Chloride in the Preparation of
99m
Tc Pharmaceuticals
the stannous chloride amount per vial covers the range from 0.0076±0.5 mg, corresponding to a ratio of Sn to Tc in the range of 103 to 105. The amount of reductant must be strictly controlled, in particular when the ligand used stabilizes technetium in more than one oxidation states. In direct labeling of proteins, stannous chloride is administered for ªpretinningº. By incubating the protein with stannous ion, reactive disulfide bonds are reduced in addition to pertechnetate (Eckelman and Steigman 1991; Rhodes 1991). The reaction kinetics of reduction and complexation are actually affected by the ªusableº tin(II) and the ligand/tin ratio, summarized in the subsequent recommendations (Srivastava et al. 1977): · Stannous solution used for formulation should be prepared with great caution to avoid oxidation and hydrolysis. · A minimum quantity of Sn(II) and an excess of the complexing ligand (as optimized for a particular kit system) should be used. · If the kit contains very little usable tin(II), the carrier content of 99mTcO±4 solutions should be evaluated. Total technetium sometimes may exceed the reductive capacity of tin. Problems Associated with the Use of Stannous Ion. The kits could fail in the way that only a fraction of the original tin may be available in the desired form at reconstitution. Situations may occur that the kit contains very little usable tin(II), and the carrier content of the eluate may exceed the reductive capacity of tin. This is critical with kits containing a very small quantity of Sn(II) (see Table 3.1) (Srivastava et al. 1977). Furthermore, an undesirable side reaction between tin and technetium may occur. As outlined above, there is a high excess of tin ± as Sn(II) and Sn(IV) ± over technetium and this fact leads to the idea that mixed-metal complexes may be formed in radiopharmaceutical preparations. Interest in the question, whether stannous or stannic tin could be involved in the radiopharmaceutical was further stimulated by the formation of a tincapped 99Tc-dimethylglyoxime complex, 99Tc(oxime)3(l-OH)SnCl3 (Deutsch et al. 1976). However, this compound was prepared under the condition of carrier-added technetium; its ready conversion to uncapped species gives no evidence for the existence of mixed-metal type compounds. The behavior of stannous ion in kit preparations has been studied in a limited number of compounds, and the conclusion reached so far indicates that, apparently, tin ions only reduce TcO±4 and indeed, apart from some tin-essential preparations such as stannous oxide colloid labeled with 99mTc (Subramanian and McAfee 1970), mixed Tc±Sn complexes have not been observed in low-molecular-weight radiopharmaceutical preparations. Another aspect is hydrolysis and colloid formation. During the reduction of pertechnetate with stannous salts, tin is oxidized and hydrolyzed to form highly polydispersed colloidal particles. In some cases, mainly when weak or unsuitable ligands are used in the 99mTc labeling, interference of colloidal tin oxides on the biodistribution of 99mTcradiolabeled tracers may occur. Such effects and the biodistribution of 99mTc-Sn colloid in dependence of the preparation conditions were subject of detailed studies. Some authors hope to prevent complications related to the use of stannous chloride by using other stannous salts such as stannous fluoride, oxalate, tartrate, citrate, and phosphates. Some efforts were made to use stannous ion fixed to a carrier to improve the labeling procedure. Albumin was labeled using stannous ion adsorbed to an ion-exchange
63
64
3.2 Stannous Chloride: the Preferred Reducing Agent for Tc Pharmaceuticals
resin in the presence of albumin and pertechnetate (Dreyer and Mçnze 1969); an insoluble macromolecular Sn(II) complex (R-Sn) was proposed in order to avoid the disadvantages of stannous chloride being hydrolized and oxidized (Nakayama et al. 1995). Reduced, hydrolized 99mTc is a colloidal impurity in kit preparations. Depending on the amount present, it may distort the biodistribution pattern and limit the diagnostic value of the 99mTc pharmaceutical. The biodistribution of 99mTc-Sn colloid itself was studied separately (Syhre et al. 1976). The authors observed that the liver-to-kidney ratio is highly dependent on the pH of the preparation, reflecting the hydrolytic properties of tin hydroxide. Furthermore, it has been shown that tin participates in the chemical binding process between technetium and tetracycline and similarly, it might very well explain how some other complexes are produced (Alvarez 1975). A more recent example is the biodistribution of 99mTc-radiolabeled chitosan nanoparticles, using two different methods for reduction, namely, stannous chloride or sodium borohydride. The authors reported a considerable dependence on the method used. They concluded that nanoparticles are adsorbed on the surface of colloidal tin oxide particles that are generated during the labeling process (Banerjee et al. 2005). Tin as a Foreign Element in the Body. The toxicity of tin compounds is related to the chemical form. The LD50 of stannous chloride in dogs (intravenous) is 20±50 mg/ kg. The toxicology of colloidal tin oxide was thoroughly investigated (Fisher 1957). Data indicated that four doses as high as 350 mg/kg of tin produced no toxicity. Because of the low doses of tin applied in 99mTc pharmaceuticals, no toxic effects are expected. Determination of Sn(II) (Quality Control). Determination of the Sn(II) content in radiopharmaceutical kits is an important aspect of quality control for commercial producers and registration authorities (Rakias and Zolle 1997). Classical methods for the determination of Sn(II) involve titrimetric, electrochemical, spectrophotometric, and chromatographic methods (Lejeune et al. 1996). Titrimetric methods that are selective for Sn(II) are generally less sensitive. Disadvantages that may occur are related to so-called matrix effects, that is, the reaction of milieu, including the presence of ligands or stabilizers, low sensitivity, or slow formation of colored complex. Thus, iodometric titration as well as spectrophotometry by means of Dithiol-Reagent R are used to determine Sn(II) in, e.g., stock solution, but are not suitable to determine Sn(II) in kits. Methods that allow specification of Sn(II) and Sn(IV) are few. There is, as an example, a colorimetric determination of the Sn(II) concentration in Tc-mercaptoacetyltriglycine (MAG3) kits based on a molybdate±thiocyanate complex formed in the presence of Sn(II) (Hoffmann et al. 1990). Pulse polarography has offered considerable advantages over the classical methods for the determination of the Sn(II) content, in particular an increase of sensitivity that allows suitable measurements of microgram amounts of tin(II) (Lejeune et al. 1996; Rakias and Zolle 1997).
Chapter 3 Stannous Chloride in the Preparation of
99m
Tc Pharmaceuticals
References Alberto R, Abram U (2003) 99mTc: labeling chemistry and labeled compounds. In: Verts A, Nagy S, Klenscr Z (eds) Radiochemistry and radiopharmaceutical chemistry in life science, handbook of nuclear chemistry, vol. 4. Kluwer, Dordrecht, pp 211±256 Alvarez J (1975) Radiopharmaceuticals prepared with stannous chloride. J Radioanal Chem 27:475± 482 Banerjee T, Singh AK, Sharma RK, Maitra AN (2005) Labelling efficiency and biodistribution of technetium-99m labeled nanoparticles: interference by colloidal tin oxide particles. Int J Pharm 289:189±195 Benjamin PP (1969) A rapid and efficient method of preparing 99mTc-human serum albumin: its clinical applications. Int J Appl Radiat Isot 20:187±194 Benjamin PP, Rejali A, Friedell H (1970) Electrolytic complexation of 99mTc at constant current: its application in nuclear medicine. J Nucl Med 11:147±154 Clarke MJ, Podbielski L (1987) Medical diagnostic imaging with complexes of 99mTc. Coord Chem Rev 78:253±331 Deutsch ME, Redmond ML (1972) Unitary freeze-dried kits for preparation of technetium-labeled human serum albumin. J Nucl Med 13(Abstr):426±427 Deutsch E, Elder RC, Lange BA, Vaal MJ, Lay DG (1976) Structural characterization of a bridged 99 Tc-Sn-dimethylglyoxime complex ± implications for chemistry of 99mTc-radiopharmaceuticals prepared by Sn(II) reduction of pertechnetate. Proc Natl Acad Sci USA 73:4289 Deutsch E, Libson K, Becker CB (1980) Preparation and biological distribution of technetium diphosphonate radiotracers synthesized without stannous ion. J Nucl Med 21:859±866 Deutsch E, Glavan KA, Sodd VJ (1981) Cationic 99mTc complexes as potential myocardial imaging agents. J Nucl Med 22:897±907 Donaldson JD, Moser W (1960) Pure tin(II) sulfate. J Chem Soc 4000±4003 Dreyer R, Mçnze R (1969) Markierung von Serumalbumin mit 99mTechnetium [in German]. Wiss Z Karl Marx Univ Leipzig, Math-Naturwiss R 18:629±633 Dworkin HJ, Gutkowski RF (1971) Rapid closed system production of 99mTc-albumin using electrolysis. J Nucl Med 12:562±565 Eckelman WC, Richards P (1970) Instant 99mTc-DTPA. J Nucl Med 11:761±762 Eckelman WC, Meinken G, Richards P (1971a) Chemical state of 99mTc in biomedical products. J Nucl Med 12:596±600 Eckelman WC, Meinken G, Richards P (1971b) 99mTc-human serum albumin. J Nucl Med 12:707±710 Eckelman WC, Richards P (1972) Analytical pitfalls with 99mTc-labelled compounds. J Nucl Med 13:202±204 Eckelman WC, Steigman J (1991) Direct labelling with 99mTc. Nucl Med Biol 18:3±7 Fischer HW (1957) Colloidal stannic oxide ± animal studies on a new hepatolienographic agent. Radiology 68:488±498 Gil MC, Palma T, Radicella R (1976) Electrolytical labelling of 99mTc-radiopharmaceuticals. Int J Appl Radiat Isot 27:69 Greenland WEP, Fogelman I, Blower PJ (2002) Direct labelling via simultaneous reduction of pertechnetate and a disulfide bond. In: Nicolini M, Mazzi U (eds) Tc, Re and other metals in chemistry and nuclear medicine 6. SG Editoriali, Padova, Italy, pp 495±498 Hoffmann I, May K, Noll B (1990) Determination of tin(II) concentration in ROTOP MAG-3 kit. Zentralinstitut Kernforschung Rossendorf, Dresden, Annual Report ZfK 711:46±47 Kalincak M, Machan V, Vilcek S (1982) 99mTc-labelled compounds prepared with Ti(III) as reducing agent. Isotopenpraxis 18:334±338 Kremer C, Leon A, Gambino D (1989) Solid-phase reduction of (TcO±4)-99mTc with zinc ± a method for the preparation of difficult 99mTc compexes. J Labelled Comp Radiopharm 27:1331±1340 Lejeune R, Thunus J, Thunus L (1996) Polarographic determination of (Sn(II) in samples containing Sn(IV) such as in technetium-99m radiopharmaceutical kits. Anal Chim Acta 332:67±71 Lin SM, Winchell HS, Shipley BA (1971) Use of Fe(II) or Sn(II) alone for technetium labelling of albumin. J Nucl Med 12:204±211 Mçnze R (1980) Electrochemical investigation on the reduction of 99TcO±4 with tin(II) in the presence of citrate. Radiochem Radioanal Lett 43:219±224 Nakayama M, Terahara T, Wada M, Ginoza Y, Harada K, Sugii A, Nakayama H (1995) Insoluble macromolecular Sn(II) complex for the 99mTc labelling of protein-bearing mercapto groups. In: Nicolini M, Mazzi U (eds) Tc, Re and other metals in chemistry and nuclear medicine 4. SG Editoriali, Padova, Italy, pp 299±320
65
66
References Noronha OPD (1978) Time-dependent characteristics on Sn-complexes for preparing 99mTc-labelled radiopharmaceuticals and their bioavailabilities ± a review. Nuklearmedizin 17:110±125 Novotnik DP (1990) Physico-chemical concepts in the preparation of technetium radiopharmaceuticals. In: Sampson CB (ed) Textbook of radiopharmacy: theory and practice. Gordon and Breach, Philadelphia, pp 29±49 Persson RBR, Liden K (1969) 99mTc-labelled human serum albumin ± a study of labelling procedure. Int J Appl Radiat Isot 20:241 Rakias F, Zolle I (1997) Stannous ion determination: importance and relevance for radiopharmaceutical kits. In: Bergmann H, Kroiss A, Sinzinger H (eds) Radioactive isotope in clinical medicine and research, vol. 22. Birkhauser, Basel, pp 401±409 Rhodes BA (1991) Direct labelling of proteins with 99mTc. Nucl Med Biol 18:667±676 Schwochau K (2000) Technetium ± chemistry and radiopharmaceutical applications. Wiley, New York, p 44 Smith JE, Byrne EF, Cotton FA (1978) Thiol complex of technetium pertinent to radiopharmaceutical use of 99mTc. J Amer Chem Soc 100:5571±5572 Spies H, Johannsen B, Mçnze R, Unverferth K (1978) Die Reduktion von Pertechnetat mit Cystein [in German]. Z Anorg Allg Chem 447:215±220 Srivastava SC, Meinken G, Smith TD, Richards P (1977) Problems associated with stannous 99mTcradiopharmaceuticals. Int J Appl Radiat Isot 28:83±95 Srivastava SC, Richards P (1983) Technetium-labelled compounds. In: Rayudu GVS (ed) Radiotracers for medical applications, CRC series in radiotracers in bioliology and medicine. CRC Press, Boca Raton, pp 107±185 Steigman J, Eckelman WC, Meinken G, Isaacs HS, Richards P (1974) The chemistry of technetium labeling of radiopharmaceuticals by electrolysis. J Nucl Med 15:75±80 Steigman J, Richards P (1974) The chemistry of technetium. Sem Nucl Med 4:269±279 Steigman J, Meinken G, Richards P (1975) The reduction of pertechnetate-99 by stannous chloride-I. The stoichiometry of the reaction in HCl, in a citrate buffer and in a DTPA buffer. Int J Appl Radiat Isot 26:601±609 Stern HS, Zolle I, McAfee JG (1965) Preparation of 99mTc-labelled serum albumin. Int J Appl Radiat Isot l6:283±288 Subramanian G, McAfee JG (1970) Stannous oxide colloid labeled with 99mTc or 113mIn for bone marrow imaging. J Nucl Med 11:365±366 Syhre R, Spies H, Johannsen B (1976) Die Organverteilung von 99mTc(Sn)-Hydroxidkolloid in der Ratte in Abhångigkeit vom Pråparations-pH [in German]. Radiobiol Radiother 17:747±750 Thomas RW, Estes GW, Elder RC (1979) Technetium radiopharmaceutical development. I. Synthesis, characterization and structure of dichloro[hydrotris(1-pyrazolyl)borate]oxo-technetium(V). J Amer Chem Soc 101:4581 Vanderheyden JL, Ketring AR, Libson K, Heeg MJ, Roecker L, Motz P, Whittle R, Elder RC, Deutsch E (1984) Synthesis and characterization of cationic technetium complexes of 1,2-bis(dimethylphosphino)ethane (DMPE) ± structure determinations of trans-[Tc-(DMPE)2(OH)(O)](F3CSO3)2, trans-[Tc-III(DMPE)2CL2]F3CSO3 and [Tc-I(DMPE)3]+ using x-ray-diffraction, EXAFS and 99Tc NMR. Inorg Chem 23:3184±3191 Vilcek S, Kalincak M, Machan V (1982) Analysis of 99mTc-labelled compounds using Sorb-Gel method. Radiochem Radioanal Lett 52:55±64 Vilcek S, Machan V, Kalincak M (1984) 99mTc-labelled compounds prepared with molybdenum(III) as reducing agent. Int J Appl Radiat and Isot 35:228±230 Vilcek S, Kalincak M, Machan V (1985) 99mTc-labelled compounds prepared with tungsten(III) as the reducing agent. J Radioanal Nucl Chem 88:359±367 Wardell JL (1994) Tin: inorganic chemistry. In: King RB (ed) Encyclopedia of inorganic chemistry, vol. 8. Wiley, New York, pp 4159±4197 Yokoyama A, Kominami G, Harada S (1975) The role of ascorbic acid with the ferric ion in labelling human serum albumin with 99mTc. Int J Appl Radiat Isot 26:291±299 Zolle I, Oniciu L, Hæfer R (1973) Contribution to the study of the mechanism of labelling human serum albumin (HSA) with Technetium-99m. Int J Appl Radiat Isot 24:621±626
Chapter 4
Quality Assurance of Radiopharmaceuticals
4
T. Bringhammar and I. Zolle This chapter deals with neither the efficacy of radiopharmaceuticals nor the radiation protection of patients and workers in connection with the handling of radiopharmaceuticals.
4.1 Introduction The quality of a radiopharmaceutical product may have an effect on the safety of the patient and the outcome of a diagnostic or therapeutic procedure. The purpose of setting standards for radiopharmaceuticals is to obtain radiopharmaceuticals with uniform properties that are effective with regard to their intended use and that entail a risk that is minimal compared with the benefit obtained.
4.2 Definitions 4.2.1 Quality Assurance Quality Assurance (QA) is a wide-ranging concept that covers all matters that individually or collectively influence the quality of a product. The quality of radiopharmaceuticals must be assured and a system designed, documented, implemented, and controlled, to give a product appropriate for the intended use. A QA system takes such measures as confirming that designated preparation and QA procedures are being followed by staff at all levels. Such evaluation should be carried out periodically and should result in a written report containing recommendations for action. QA Incorporates Good Manufacturing Practice. A QA system ensures that radiopharmaceuticals are manufactured or prepared and controlled in such a way that they comply with set specifications throughout their shelf-lives. Specifications concerning radiopharmaceuticals may include parameters such as: · Identity · Radioactivity · Specific radioactivity · Assay · Chemical purity · Radiochemical purity · Radionuclidic purity · pH · Particle size
68
4.2 Definitions
· Sterility · Amount of bacterial endotoxins
4.2.2 Good Manufacturing Practice Good manufacturing practice (GMP) is that part of QA that is aimed at ensuring that radiopharmaceuticals are consistently manufactured or prepared and handled in hospitals to a quality appropriate to their intended use (Kristensen 1979; Nordic Council on Medicines 1989). It is concerned with both manufacture or preparation in hospitals, and quality control (QC). The principles and guidelines of GMP for medicinal products have been laid down in Council Directive 91/356/EEC, presented in volume IV of the European Regulations (European Economic Community 1997).
4.2.2.1 Quality Control QC is that part of GMP that is concerned with analytical testing, documentation, and evaluation to ensure that the quality of the radiopharmaceutical complies with the relevant standard (European Pharmacopeia [Ph. Eur.], (Council of Europe 2005).
4.2.2.2 Surveillance Surveillance is part of a QA program, designed to monitor quality of the radiopharmaceuticals as closely as possible. Drug defects and adverse reactions should be recorded and reported to national and/or international centers. All instances of unexpected biodistribution of radiopharmaceuticals in patients should be reviewed in order to detect whether any changes could have taken place in the quality of the radiopharmaceutical. If possible, the radiochemical purity of such a radiopharmaceutical should be determined.
4.2.2.3 Good Manufacturing Practice GMP is not product specific. It concerns how a quality system on the manufacturing of a certain kind of pharmaceutical should be set up (constructed), and what then in practice should be done to reach and maintain the construction quality in order to produce a product of satisfactory quality. The QC performed by the manufacturer of a ready-for-use product or a kit or the eventually performed QC in the hospital are not sufficient to ensure that the right quality is maintained. To get a radiopharmaceutical of satisfactory quality each time, it is important that the manufacturing process as well as the process of preparation comply with current GMP. This is of utmost significance for radiopharmaceuticals that, due to their oftenshort shelf-lives (physical and chemical), have to be released before all QC measures are performed and evaluated. That is to say, radiopharmaceuticals in most cases are administrated to the patient before the results from all tests are available.
Chapter 4 Quality Assurance of Radiopharmaceuticals
In most countries, the competent authorities have adopted GMP guidelines concerning the manufacturing of pharmaceuticals (European Economic Community 1997). These guidelines often contain supplements concerning radiopharmaceuticals. The most important deviations from the ªnormalº guidelines are arrangements in connection with radiation protection and that the release is permitted before all QC tests on the finished product have been performed and evaluated. Which control tests may be performed and evaluated after release is settled when an application for approval for marketing authorization is assessed by a competent authority. It is very important that methods used for manufacture are validated. The manufacturers are inspected by national and sometimes foreign competent authorities. The same GMP guidelines are, where relevant, valid for the preparation of radiopharmaceuticals in hospitals. Some national competent authorities have issued detailed regulations about what has to be considered. Detailed requirements such as: · Competence (education and training) · Premises and equipment · Documentation · Distribution · QC · Self-inspection The preparation of radiopharmaceuticals in hospitals will normally be inspected by the national inspectorates. Within Europe GMP guidelines are governed by two international bodies: 1. Pharmaceutical Inspection Convention (PIC), which has been operating since 1970, was founded by the European Free Trade Association (EFTA) comprising initially the ten EFTA member states, i.e., Austria, Denmark, Finland, Iceland, Liechtenstein, Norway, Portugal, Sweden, Switzerland, and the United Kingdom; membership was subsequently expanded to include Hungary, Ireland, Romania, Germany, Italy, Belgium, France, and Australia. 2. Pharmaceutical Inspection Cooperation Scheme (PIC Scheme), which has been operating since 1995, was formed as an extension of PIC, offering a more flexible cooperation between PIC and health authorities outside Europe. a. PIC and PIC Scheme (jointly referred to as PIC/S) are two international instruments between countries and pharmaceutical inspection authorities, which together provide an active and constructive cooperation in the field of GMP (PIC guidelines) (European Free Trade Agreement 1992). b. PIC/S concern the following participating authorities: Australia, Austria, Belgium, Canada, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Malaysia, Netherlands, Norway, Portugal, Romania, Singapore, Slovak Republic, Spain, Sweden, Switzerland, and the United Kingdom. The main differences between the PIC Scheme and PIC are: PIC Scheme PIC Scheme Convention Informal arrangement Formal treaty Between health authorities Between countries Has no legal status Has legal status Exchange of information Mutual recognition of inspections
69
70
4.2 Definitions
Other relevant GMP guidelines were elaborated by the United States and Japan. Furthermore, WHO has elaborated GMP guidelines to be used as basis for the elaboration of national or multinational guidelines.
4.2.3 Pharmacopeias In contrast to GMP guidelines, monographs of a pharmacopeia concern a specific active ingredient or product. A pharmacopeia contains standards concerning pharmaceuticals and comprises such subjects as: · Analytical methods: identity reactions, chromatographic methods, methods of sterilization, etc. · Packaging materials · Ingredients · General monographs on radiopharmaceuticals · Ready-for-use pharmaceuticals Monographs on radiopharmaceuticals are as a rule standards with which the ready-foruse radiopharmaceuticals must comply at the time of administration, regardless of whether the pharmaceutical is a ready-for-use product from a manufacturer or has been prepared in nuclear medicine. The specifications set up in a pharmacopeia monograph are minimum standards only. At the time of an approval for marketing authorization, the manufacturer on its behalf may set tighter specifications.
4.2.3.1 Relevant Pharmacopeias Ph. Eur. The Ph. Eur. is elaborated and published under the direction of the Council of Europe in accordance with the Convention on the Elaboration of a European Pharmacopeia (Council of Europe 2005). It is published in two official languages, English and French. In Great Britain, a separate pharmacopeia is published, The British Pharmacopeia, which contains the monographs of the Ph. Eur. together with national monographs. In the same way, separate pharmacopeias are published in France, Germany, and Spain. In the Nordic countries, national monographs are published in an annual publication. United States Pharmacopeia (USP). The USP is elaborated by authority of the United States Pharmacopeial Convention (Unites States Pharmacopeia Convention 2005). When a country has signed the European Pharmacopeial Convention, the Ph. Eur. is law in that country, and pharmaceuticals have to comply with relevant monographs. For pharmaceuticals not in the Ph. Eur., other pharmacopeias may be used. These countries follow the Ph. Eur. in English, French, or equivalent translation: Albania (observer), Austria, Australia (observer), Belgium, Bosnia-Herzegovina, Bulgaria, Canada (observer), China (observer), Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Macedonia, Malta, The Netherlands, Norway, Poland (observer), Portugal,
Chapter 4 Quality Assurance of Radiopharmaceuticals
Rumania, Serbia and Montenegro, Slovenia, Slovak Republic, Spain, Sweden, Switzerland, Syria (observer), Turkey, and the United Kingdom. The appendix to this chapter comprises a list with English titles for Ph. Eur. monographs on radiopharmaceuticals together with the USP monographs. An existing Ph. Eur. monograph overrides a USP monograph.
4.2.4 Approval for Marketing Authorization of a Radiopharmaceutical A manufacturer must have a marketing authorization before a product can be marketed. In the European Union, rules (directives and guidelines) are issued concerning application for approval for marketing authorization of a product regulating which documentation must be submitted with an application (Directive 75/318/EEC, Eudralex, vols. 2A and 2B [European Economic Community 1998 a, b]). The rules are not product specific. Each member state has the authority to grant a national marketing authorization. Since 1993, there is an administrative authority responsible for medicines in the entire European Union, enacted by Council Regulation (EEC) No. 2309/93. This European Agency for the Evaluation of Medicinal Products (EMEA) is responsible for coordinating the scientific resources put at its disposal by the competent authorities of the member states for the evaluation and supervision of medicinal products for human use. A marketing authorization granted under the centralized procedure by EMEA is valid for all member states. According to the guidelines the applicant must prove that: · The manufacturing process complies with current GMP. · The ingredients and packaging materials are tested according to validated methods. · The finished product and its shelf-life (both before and after preparation) have been evaluated by validated methods. · If a product must be prepared in nuclear medicine prior to administration, evaluation of the production process at another site has to be performed under the same circumstances. If there is a monograph in the Ph. Eur. on a particular product, the manufacturer must prove that the product at least complies with the specifications of the monograph. However, normally the specifications used by the manufacturer of the finished product as well as the specifications used at in-process controls are tighter.
4.2.5 Quality Control QC on Ready-for-Use Products from a Manufacturer. These radiopharmaceuticals are to be administrated to the patient without further preparation. As the manufacturing is inspected by competent authorities in order to ensure a high quality of the production process, the QC in the hospital in most cases can be reduced to control of transport documents, labels, and radioactivity. Tests on radionuclidic or radiochemical purity are normally not required.
71
72
Appendix
QC on Products Intended to be Prepared in the Hospital. For these radiopharmaceuticals, the responsibility for the product is shared by the manufacturer(s) of starting materials and the hospital, where the radiopharmaceutical is prepared. Before approval of marketing authorization, an applicant must prove that, when prepared in a hospital, the margins between an acceptable and an unacceptable radiopharmaceutical are broad enough to permit great variations between preparation routines in different hospitals and variations between different operators performing the work. If the margins are too narrow, the product is not likely to be approved, unless the medical benefit outweighs the efforts spent on QC of each preparation before its administration to the patient. In most cases, QC on each prepared radiopharmaceutical is not necessary, except the control of radioactivity. On the other hand, QC of prepared radiopharmaceuticals should be a part of the hospital's validation of routines and working standards of personnel. QC methods that are intended to be used in hospitals must be simple, robust, and validated. Furthermore, control methods on radiochemical purity, which is the most common parameter, should easily demonstrate the radiochemical purity. It is seldom necessary to know the precise percentage of every single impurity. Manufacturers and competent national authorities have a great responsibility when evaluating the need for QC in hospitals. In other words, whether a validation of routines and working standards of personnel is sufficient, or whether it is necessary for each preparation to perform tests. At the same time, specifications on acceptable limits for clinical use must be given. The methods used for preparation and QC of approved radiopharmaceuticals must be the same as those approved by the competent authority. QC methods recommended in a relevant pharmacopeia may also be used. In the European Union, the methods are part of the Summary of Product Characteristics (SPC), the purpose and scope of which is approved by the competent authority (European Economic Community 1983). In an investigation of a patient in which something has gone wrong, the radiopharmaceutical is rarely to blame. There are many other parameters that may influence, e.g., the illness of the patient, medication, hydration, or weight. Likewise, when a defect radiopharmaceutical has been discovered, it is seldom a defect product from the manufacturer. In most cases, the fault lies with the personnel who prepared the radiopharmaceutical. Radiopharmaceuticals Manufactured in the Hospital. For such radiopharmaceuticals, the hospital has the full responsibility, and the manufacturing must follow the same rules as those for the manufacture of other pharmaceuticals.
Appendix European Pharmacopeia (Ph. Eur.) and United States Pharmacopeia (USP) monographs concerning radiopharmaceuticals Ph. Eur. 5.0 Ammonia[13N] injection Carbon monoxide[15O] injection Chromium[51Cr] edetate injection
USP 28 Ammonia N 13 injektion Carbon monoxide [C11] injection Chromium Cr 51 edetate injection Chromic phosphate P 32 suspension
Chapter 4 Quality Assurance of Radiopharmaceuticals
Ph. Eur. 5.0 Cyanocobalamin[57Co] capsules Cyanocobalamin[58Co] capsules Cyanocobalamin[57Co] solution Cyanocobalamin[58Co] solution 2-Fluoro-2-deoxy-d-glucose[18F] injection [5-methyl-11C]flumazenil injection Gallium[67Ga] citrate injection Indium[111In] chloride solution
Indium[111In] oxinate solution Indium[111In] pentetate injection
Iobenguane[123I] injection Iobenguane[131I] injection for diagnostic use Iobenguane[131I] injection for therapeutic use Albumin[125I] injection
Iodinated[131I] norcholesterol injection Krypton[81mKr] (gas) L-Methionine[methyl-11C] injection Raclopride[methoxy-11C] injection Radiopharmaceuticals (general monograph)
Sodium[111C] acetate injection Sodium fluoride[18F] injection Sodium iodide[123I] injection Sodium iodide[131I] injection Sodium iodide[131I] capsules Sodium Sodium Sodium Sodium
iodohippurate[123I] injection iodohippurate[131I] injection chromate[51Cr] sterile solution phosphate[32P] injection
USP 28 Cyanocobalamin Co 57 capsules Cyanobalamin Co 58 capsules Cyanobalamin Co 57 oral solution Fludeoxyglucose F 18 injection Fluorodopa F 18 injection Flumazenil C 11 injection Gallium citrate Ga 67 injection Indium In 111 chloride solution Indium In 111 capromab pendetide injection Indium In 111 ibritumomab tiuxetan injection Indium In 111 oxyquinoline solution Indium In 111 pentetate injection Indium In 111 pentetreotide injection Indium In 111 satumomab pendetide injection Iobenguane I 123 injection Iobenguane I 131 injection Iodinated I 125 albumin injection Iodinated I 131 albumin injection Iodinated I 131 albumin aggregated injection Krypton Kr 81m (gas) Mespiperone C 11 injection Methionine C 11 injection Raclopride C 11 injection Rose Bengal sodium I 131 injection Rubidium chloride Rb 82 injection Radioactivity (general monograph) Radiopharmaceuticals for positron emission tomography compounding Samarium Sm 153 lexidronam injection Sodium acetate C 11 injection Sodium fluoride F 18 injection Sodium iodide I 123 solution Sodium iodide I 131 solution Sodium iodide I 131 capsules Sodium iodide I 123 capsules Sodium iothalamate I 125 injection Iodohippurate sodium I 123 injection Iodohippurate sodium I 131 injection Sodium chromate Cr 51 injection Sodium phosphate P 32 solution
73
74
Appendix
Ph. Eur. 5.0 USP 28 Strontium chloride Sr 89 injection Strontium[89Sr] chloride injection Sodium pertechnetate[99mTc] injection (fission) Sodium pertechnetate Tc 99m injection Sodium pertechnetate[99mTc] injection (nonfission) Technetium[99mTc] albumin (human) injection Technetium Tc 99m albumin injection Technetium Tc 99m albumin colloid injection Technetium Tc 99m apcitide injection Technetium Tc 99m arcitumomab injection Technetium Tc 99m bicisate injection Technetium Tc 99m depreotide injection Technetium Tc 99m etidronate injection Technetium Tc 99m exametazime Technetium[99mTc] exametazime injection Technetium Tc 99m gluceptate Technetium[99mTc] gluconate injection injection Technetium Tc 99m disofenin injection Technetium Tc 99m lidofenin injection Technetium[99mTc] etifenin injection Technetium Tc 99m mebrofenin injection Technetium Tc 99m albumin aggreTechnetium[99mTc] macrosalb injection gated injection Technetium Tc 99m medronate Technetium[99mTc] medronate injection injection Technetium Tc 99m mertiatide Technetium[99mTc] mertiatide injection injection Technetium[99mTc] microspheres injection Technetium Tc 99m nofetumomab merpentan injection Technetium Tc 99m oxidronate injection Technetium Tc 99m pentetate injection Technetium[99mTc] pentetate injection Technetium Tc 99m (pyro- and trimeta-) phosphates injection Technetium Tc 99m pyrophosphate Technetium[99mTc] Tin pyrophosphate injection injection Technetium Tc 99m red blood cells Technetium[99mTc] colloidal rhenium sulfide injection injection Technetium[99mTc] sestamibi injection Technetium[99mTc] succimer injection Technetium Tc 99m sestamibi Technetium[99mTc] sulfur colloid Injection injection Technetium Tc 99m succimer injection Technetium Tc 99m sulfur colloid injection
Chapter 4 Quality Assurance of Radiopharmaceuticals
Ph. Eur. 5.0 Technetium[99mTc] tin colloid injection Thallous[201Tl] chloride injection Tritiated[3H] water injection Water[15O] injection Xenon[133Xe] injection
USP 28 Technetium Tc 99m tetrofosmin injection Thallous chloride Tl 201 injection Urea C 14 capsules Water O 15 injection Xenon Xe 133 injection Xenon Xe 127 (gas) Xenon Xe 133 (gas) Yttrium Y 90 ibritumomab tiuxetan injection
References Council of Europe (2005) European pharmacopeia, 5th edn. Maisonneuve, Sainte-Ruffine European Economic Community (1983) Council Directive 83/570/EEC (26 October 1983), Summary of product characteristics. European Economic Community, Luxembourg European Economic Community (1997) Pharmaceutical legislation: good manufacturing practices for medicinal products for human and veterinary use (Directive 91/356/EEC). Eudralex, vol. IV. European Economic Community, Luxembourg European Economic Community (1998 a) Notice to applicants: procedures for marketing authorization. Medicinal products for human use. (Directive 75/318/EEC; Regulation (EEC) No 2309/93). Eudralex, vol. IIA. European Economic Community, Luxembourg European Economic Community (1998 b) Notice to applicants: presentation and content of the dossier. Medicinal products for human use (Directive 75/319/EEC, resp. Regulation (EEC) No 2309/93; Directive 89/343/EEC). Eudralex, vol. IIB. European Economic Community, Luxembourg European Free Trade Agreement (1992) Guide to good manufacturing practice for pharmaceutical products, the convention for the mutual recognition of inspections in respect of the manufacture of pharmaceutical products, Document 5/92 (PIC guidelines on GMP). European Free Trade Agreement, Geneva United States Pharmacopeial Convention (2005) Official monographs: USP28. United States Pharmacopeia Convention, Rockville, Md. Kristensen K (1979) Preparation and control of radiopharmaceuticals in hospitals. International Atomic Energy Agency, Vienna Nordic Council on Medicines (1989) Radiopharmacy: preparation and control of radiopharmaceuticals in hospitals. National Library of Norway publication No. 26, Uppsala
75
Chapter 5
5
Performance and Quality Control of the 99Mo/99mTc Generator I. Zolle
Radionuclide generators serve as a convenient source of short-lived radionuclides for medical application. Daily supply with short-lived radionuclides is limited by the halflife and the cost of transport. Certain decay sequences, however, exist in an equilibrium state between the parent nuclide and the decay product, i.e., the daughter nuclide. In principle, the longer-lived parent radionuclide generates the shorter-lived daughter by radioactive decay. The type of equilibrium depends on the relative half-lives of the parent and daughter radionuclides. The growth of the daughter radionuclide continues until a maximum is reached; since parent and daughter radionuclides are different elements, the radioactive daughter can be separated by a simple chemical process, generally by liquid elution. The lifetime of a generator system depends on the half-life of the parent nuclide. The longer the half-life of the parent, the longer can daughter radionuclide be eluted in adequate amounts. This condition is favorable for both transport and the use of shortlived radionuclides in diagnostic nuclear medicine (Eckelman and Coursey 1982; Richards 1966). A number of generator systems have been developed for medical application, but only few have found widespread acceptance. Table 5.1 gives some examples of generators used in nuclear medicine (Boyd et al. 1985). A radionuclide generator consists of a glass column filled with an adsorbent material such as aluminum oxide or an ion-exchange resin to which the parent nuclide is bound (Richards 1966). The column is fitted with a filter at the outlet to retain particulate matter. On top is the elution platform, where an evacuated sterile vial is connected with the outlet of the column through which saline or another suitable eluent is drawn from the eluent reservoir. 99 Mo/99mTc generators produced for worldwide application have a sophisticated system for safe elution of the daughter radionuclide. The generator column is well shielded with lead, and the whole system must be adequately shielded to reduce radiation exposure of the operator to a permissible level (Fig. 5.1).
Table 5.1. Generator systems for medical application of short-lived radionuclides Parent nuclide
Decay mode
T1/2
Daughter nuclide
Energy (keV)
T1/2
99
b± EC EC, b+ EC EC
66.02 h 115.1 days 4.58 h 25 days 288 days
99m
141 392 190 (b+, EC) (b+, EC)
6.02 h 1.66 h 13.3 s 1.25 min 68.3 min
Mo Sn 81 Rb 82 Sr 68 Ge 113
T1/2 half-life, EC electron capture
Tc In Kr 82 Rb 68 Ga 113m 81m
78
5.1 The Equilibrium State
Fig. 5.1. Components of the
99
Mo/99mTc generator system
5.1 The Equilibrium State Parent 99Mo and the short-lived daughter 99mTc reach transient equilibrium, characterized by the decay of both parent and daughter radionuclides with one apparent halflife, namely that of the longer-lived 99Mo (Richards 1966). Transient equilibrium is established when the half-life of parent is long with respect to daughter radionuclide, but parent activity changes perceptibly during the period under consideration. Buildup of daughter 99mTc activity occurs until a maximum is reached, and then the ªeffectiveº half-life of the daughter activity will be essentially equal to the parent half-life, as long as parent activity continues to produce the daughter radionuclide. The ratio of daughter activity to parent activity is unchanging with respect to time, but the activity of each is declining with respect to time: A2/A1 = constant (Boyd 1982; Richards 1966). The decay sequence of 99Mo, with a half-life of 66.02 h, is shown in Fig. 5.2 (Boyd 1982).
Fig. 5.2. Decay scheme of parent
99
Mo to stable
99
Ru
Chapter 5 Performance and Quality Control of the
99
Mo/99mTc Generator
The 99Mo parent radionuclide decays by several b-particle transitions (two shown), producing metastable 99mTc with 87.5% intensity, while 12.5% decay directly to longlived 99Tc. Subsequently, metastable 99mTc decays by isomeric transition to 99Tc with a half-life of 6.02 h and emission of 140.5 keV gamma radiation. 99Tc decays with a halflife of 212 000 years to stable ruthenium-99 (Boyd 1982).
5.1.1 Production of Molybdenum-99 Irradiation of metallic 98Mo or molybdenum trioxide, Mo2O3 (natural or enriched in 98 Mo), with thermal neutrons in a nuclear reactor: 98
Mo
n; c99 Mo
Large quantities of natural target may be irradiated to give a high yield of 99Mo (Robson 1972). High yields are also obtained by subjecting an enriched 98Mo target to highintensity neutron irradiation in excess of 1014 neutrons/cm2´s. However, the price of this target material is very high (Boyd 1982). Consequently, for large-scale production, this method is rarely used. Radionuclidic impurities result from activation of metallic impurities present in the target material (Boyd 1973). Advantages of neutron activation are (1) post±irradiation processing is minimal, (2) radionuclidic contaminants are limited by target purity, and (3) only small quantities of radioactive waste are produced. A disadvantage is the low specific activity of 99Mo (< 10 Ci/g Mo). Irradiation of 235U with thermal neutrons and separation of 99Mo from fission products: 235
U
n; f . . .99 Mo
An advantage of fission-product 99Mo is the high specific activity of 99Mo (> 104 Ci/g Mo). Disadvantages are the (1) elaborate and expensive post±irradiation processing facilities, (2) chemical separation of the highly-toxic a-emitters (transuranic radionuclides) and pure b-emitters, (3) special problems of quality control, and (4) large quantities of long-lived radioactive waste. 99 Mo is separated from other radionuclides generated by this process (Barnes and Boyd 1982). Strict limits for radionuclidic impurities are stated in the monograph on sodium pertechnetate [99mTc] injection solution (Council of Europe 2005 a).
5.1.2 Separation Methods Several methods have been used to separate the daughter nuclide 99mTc from parent 99 Mo, the three most common methods are column chromatography, solvent extraction, and sublimation (Boyd 1982; Richards 1982). The 99Mo/99mTc generator used in nuclear medicine is based on the chromatographic separation of 99mTc-pertechnetate.
79
80
5.1 The Equilibrium State
5.1.3 Design of the Generator Column 99
Mo is bound strongly to a bed of chromatographic-grade alumina. The daughter radionuclide 99mTc is eluted by selective elution from the Al2O3 column. Both 99Mo and the decay product 99mTc are bound as anions; however, parent 99Mo shows the strongest fixation. Due to considerable differences in the binding affinities, a pertechnetate anion may be replaced by a nitrate or chloride anion, as is indicated by the order of affinities of anions: OH > MoO24 > Cl > NO3 > TcO4 Sterile saline is used for elution of the 99mTc activity as Tc(VII)O4-pertechnetate anion. The sterile, isotonic eluate may be used directly in patients; however, most of the 99m Tc activity is needed for the preparation of 99mTc radiopharmaceuticals with preformed kits. Aluminum oxide is pretreated by activation at high temperature (250 8C) to resist structural changes in the high-radiation environment and to reduce acid solubility. Silver coating of the alumina particles has a similar effect and provides a higher capacity of the alumina matrix for fixation of 99Mo-molybdate (Barnes and Boyd 1982). Fission-produced molybdenum-99 offers considerable advantages for generator production: · High specific activity 99Mo-molybdate is applied to the column, permitting small amounts of alumina and small columns. · Small chromatographic columns result in a small elution volume and thus, a higher concentration of activity in the eluate. · Smaller columns can be shielded more easily, not increasing the weight of the generator. This is important for the transport and handling of the generator in the medical facility. With fission-produced 99Mo, the column for a 500-mCi generator requires approximately 1.2 g of aluminum oxide. The applied mass is by a factor of 1000 less than with previously used irradiation-produced 99Mo; the elution volume is generally 5 ml, containing 80% of the theoretically available activity. To date, practically all commercially available generators are produced with fission-produced 99Mo; problems with 99Mo breakthrough do not exist. An acceptable contamination of the eluate with 99Mo is highest in the first eluate, decreasing with daily elutions. In comparison, former irradiation generators used larger columns suitable for approximately 20 g of alumina and an elution volume between 15 and 20 ml. The resulting activity concentration was much lower and the so-called 99Mo breakthrough posed a considerable hazard (Richards and O'Brien 1969). Typically, contamination of the eluate with 99Mo was increasing with daily elutions.
5.1.4 The Generator Eluate The 99Mo/99mTc generator is a closed system providing sterile 99mTc eluate on a daily basis. Generators are available from manufacturers with a wide range of 99Mo activities (2±43 GBq; 54±1.162 mCi); sterile, evacuated vials are supplied with the generator, offering also variable elution volumes (5, 10, 15, and 20 ml).
Chapter 5 Performance and Quality Control of the
99
Mo/99mTc Generator
Sterile saline is used for elution of the generator. The eluate is a clear, colorless, isotonic solution of 99mTc(VII)-pertechnetate. The concentration of the 99mTc activity in the eluate (99mTc activity/volume) depends on the available 99Mo activity and the elution volume. With daily elution of the generator, high specific activity is assured.
5.2 Performance of the
99
Mo/99mTc Generator System
The European Pharmacopeia (Ph. Eur.) contains two separate monographs for sodium pertechnetate [99mTc] injection solutions, depending on the source of 99Mo used for production of the generator, natrii pertechnetatis [99mTc] fissione formati solutio iniectabilis (monograph 124) (Council of Europe 2005 a), and natrii pertechnetatis [99mTc] sine fissione formati solutio iniectabilis (monograph 283) (Council of Europe 2005 b). The following quality criteria are stated in the Ph. Eur. and should be evaluated for each generator: · Elution efficiency (percentage) · Radionuclidic purity of the eluate · Radiochemical purity of the eluate · Chemical purity of the eluate · pH of the eluate
5.2.1 Elution Efficiency The performance of a generator system is expressed by the elution efficiency, which is defined as the fraction of eluted 99mTc activity of the theoretically available radioactivity at the time of elution, usually given as a percentage. The yield varies with different generator systems, and is generally between 80 and 100% of the theoretical value; however, daily elutions should represent a constant percentage, fluctuations as shown in the graph (Fig. 5.3) indicate poor performance.
Fig. 5.3. Elution efficiency of a
99
Mo/99mTc generator (daily elution)
81
82
5.2 Performance of the
99
Mo/99mTc Generator System
Fig. 5.4. Typical elution profile of a fission 99Mo generator using three fractions (2.1, 2.4, and 2.6 ml), eluting 86% of the theoretically available radioactivity in the first 3 ml
Generators produced with high specific activity fission molybdenum-99 may be eluted with a small volume of saline, showing a narrow elution profile, as indicated by the graphic presentation (Fig. 5.4). Still, there are differences in the elution pattern between generator systems from different producers. Therefore, it may be beneficial to know the elution profile of each generator used at a medical facility. The elution profile may be obtained from the manufacturer on request, or it may be determined by fractional elution using 1- to 2-ml fractions and measuring the eluted activity of each sample. Shown are elution efficiencies obtained with two generator systems manufactured by different producers. Generator I shows 61.6% of the eluted radioactivity in the first 3 ml shown in Fig. 5.5, whereas elution of generator II shows the major activity peak in the fractions between 3 and 5 ml (Fig. 5.6). Both generators are totally eluted with 5 mL of saline. Fractional elution may be indicated when small volumes of high activity are needed for bolus injection or for labeling. In the case of generator I, it will suffice to elute a total volume of 3 ml, while two 3-ml fractions should be obtained in the case of generator II, since the main activity peak is collected in the second fraction.
5.2.2 The Kinetics of Decay and Growth of the 99Mo/99mTc Generator After elution of the generator column, the 99mTc activity builds up until a maximum is reached after approximately four half-lives (22.89 h). Equilibrium between mother and daughter activity is established later, after 43.9 h. A schematic presentation depicts the growth of 99mTc activity after daily elution in relation to decreasing parent 99Mo, and the equilibrium state after day 5, when no elution is performed (Boyd 1982; Richards 1966; Fig. 5.7). The theoretically available 99Mo activity of a 100-mCi generator and buildup of 99m Tc activity is shown in the decay±growth graph (Fig. 5.7).
Chapter 5 Performance and Quality Control of the
99
Mo/99mTc Generator
83
Fig. 5.5. Elution of generator I (n = 67), using fractions of 1.6±3.0 ml, showing 61.6Ô8.3% in the first fractions and 16.2 Ô5.9% in the second fractions, with an overall elution efficiency of 77.8Ô4.2%
Fig. 5.6. Elution of generator II (n = 67) using fractions of 1.0±2.5 ml, showing 21.8 Ô 20.4% in the first fractions and 57.2 Ô 18.3% in the second fractions, with an overall elution efficiency of 80.4 Ô 10.8%
Calculation of the available
99m
Tc activity:
A1 A0 e
k1 t
A2 A0 e
k1 t
ATc
AMo-99
t0 0:96
1
99m
t
indicates parent activity at any time e
k2 t
indicates daughter activity at time; t e
0:105t
1
2
3
A0 = 99Mo activity at time of calibration A1 = 99Mo activity at time, t (h) A2 = 99mTc activity at time, t (h) k1 = decay constant of 99Mo = 0.0105 (h±1) k2 = decay constant of 99mTc = 0.1155 (h±1) Parent activity (A1) is expressed by Eq. 1, considering the radioactive decay during the time (t). Daughter activity (A2) is a function of parent decay and the decay of daughter during the time (t), expressed by Eq. 2. The available 99mTc activity at any time may be calculated using Eq. 3.
5.2 Performance of the
99
Mo/99mTc Generator System 99
Mo/99mTc-generator
The decay-growth of the
100
100.0
77.7
60.4
46.9
36.5
28.4
22.0 17.1 (% parent activity)
99
Mo-decay
Radioactivity (%)
84
10
99m
Tcbuild-up 1 0
1
2
3
4
5
6
7
Time (days) Fig. 5.7. Radioactive decay of parent calculated for 7 days
99
Mo and buildup of
99m
Tc activity within 24 h after elution,
A 99Mo/99mTc generator (100 mCi) provides sufficient 99mTc activity for 5 days, as is indicated by the radioactive decay of parent 99Mo (Table 5.2). It is apparent from Table 5.3 that the daily available 99mTc activity may be simply obtained by subtracting 6.25% from A1 (decay of 99mTc during 24 h). After 99mTc activity has reached its maximum at 22.89 h, the available activity is effectively determined by the decay of parent activity. For any time (t) that is short with respect to the half-life of parent 99Mo, Eq. 4 may be used for calculating the available daughter activity after the last elution. A2 A0
1
e
k2 t
indicates build-up of daughter activity from zero to maximum activity with respect to time
t T1=2P
4
Table 5.2. Radioactive decay of parent ±k,t
Time (h)
e
24 48 72 96 120 144 168
0.7772 0.6041 0.4695 0.3649 0.2837 0.2205 0.1714
99
Mo (A0 100 mCi) A1 (mCi) 77.72 60.41 46.95 36.49 28.37 22.05 17.14
Chapter 5 Performance and Quality Control of the Table 5.3.
99
Mo decay and
99
Mo/99mTc Generator
99m
Tc buildup
±k,t
Time (h)
e
1 3 6 9 12 18 24 48 72 96
0.9896 0.9690 0.9389 0.9098 0.8816 0.8278 0.7772 0.6041 0.4695 0.3649
e±k2t
A2 (%)
0.8909 0.7072 0.5001 0.3536 0.2501 0.1251 0.0625 0.0039 0.0002 0.0000
9.87 26.18 43.88 55.62 63.15 70.27 71.47 60.02 46.93 36.49
5.2.3 Factors Affecting the Elution Yield Actually, the elution yield of 99mTc activity is considerably less than calculated due to retention of certain 99mTc species and other factors. Small concentrations of dissolved organic impurities in the eluent have been shown to cause reduced efficiencies (Molinski 1982). Purification of the eluent by passage through activated charcoal maintained high elution efficiencies. If the generator is constructed of materials that release organic contaminants on autoclaving, the generator may be poisoned; this cannot be restored by the use of a charcoal filter in the inlet line. Extracts from plastic materials, residual glue (cyclohexanone), and disinfectant (propan-1-ol), all have been identified to reduce the elution yield (Boyd et al. 1985). The effect of radiolysis, on the other hand, has been discussed controversially.
5.2.4 Elution of Carrier
99
Tc
Long-lived 99Tc atoms pose an inherent isotopic impurity that is eluted from the column and is also generated in the eluate by radioactive decay of 99mTc. Since the concentration of 99mTc in the eluate is very low, chemical effects may result when generators are not eluted at regular intervals. The total mass of technetium (99mTc + 99Tc) in the 24-h eluate is calculated as 6.90 ´ 10±10 g/37 MBq (1 mCi). (For calculation of specific activity, see Appendix A2 of this chapter) For a given generator, the amount of 99Tc carrier atoms in the eluate is dependent on: · Time elapsed since last elution · Time interval between elution and use · Elution efficiency A considerable increase of 99Tc carrier has been demonstrated when there is a gap between elutions, as is the case over weekends (Bonnyman 1983). Table 5.4 shows the calculated amounts of 99Tc carrier, assuming 10 GBq (270 mCi) of eluted activity and different times of decay before elution of the generator. The effect of low elution efficiency on subsequent elutions has also been investigated, resulting in an increase of 99Tc carrier with each elution (Boyd et al. 1985).
85
86
5.3 Purity of Generator Eluate (Ph. Eur.) Table 5.4. Carrier
99
Tc in eluates, depending on time elapsed between elutions Activity: 10 GBq (270 mCi)
Time between elutions
24 h
27 h
3 days
4 days
Amount of 99Tc carrier (lg) in eluate Expressed as 10±10 g per 37 MBq (1 mCi)
0.186 6.9
0.208 7.7
0.679 25.15
1.036 38.37
Therefore, generators should be eluted regularly and completely; this is especially important for those generator types with reduced efficiencies. Insufficient understanding of these factors can lead to a significant loss of quality of the 99mTc eluate.
5.3 Purity of Generator Eluate (Ph. Eur.) 5.3.1 Radionuclidic Purity Radionuclidic impurities in the eluate are directly related to the production mode of parent 99Mo. In any case, 99Mo is the most important impurity. The limit of contamination with 99Mo stated in the Ph. Eur. is 0.1% of the total eluate activity. With irradiation-produced molybdenum-99, other radionuclidic impurities are limited to 0.01% of the total radioactivity. Identified impurities include Sn-113, Au-198, Au-199, Cs-134, and Nb-92. On the other hand, fission-produced molybdenum-99 may contain a number of radionuclidic impurities (Briner and Harris 1974; Hammermaier et al. 1986). Limits of contamination are listed in Table 5.5 with reference to the radionuclide and type of radiation. Table 5.5. Limits of radionuclidic impurities in the eluate of fission Pharmacopeia)
99
Mo generators (European
Radionuclide
Type of radiation
Limit (%)
99
(c, b±) (c, b±) (c, b±) (pure b±-emitter) (pure b±-emitter)
1 ´ 10±1 5 ´ 10±3 5 ´ 10±3 6 ´ 10±5 6 ´ 10±6 1 ´ 10±7 1 ´ 10±2
Mo I 103 Ru 89 Sr 90 Sr a-emitters c-emitters 131
5.3.2 Radiochemical Purity Technetium may exist in seven oxidation states. In the 99mTc eluate, the chemical species is 99mTc(VII)-pertechnetate. The Ph. Eur. states that not less than 95% of the radioactivity is identified as sodium pertechnetate [99mTc] by paper chromatography.
Chapter 5 Performance and Quality Control of the
99
Mo/99mTc Generator
5.3.3 Chemical Purity The eluate may contain certain chemical impurities, originating from either the generator column or the eluent. Aluminum cations are formed during absorption of 99Mo, when the alumina bed is subjected to strong acid (1 M HNO3), and may be detected in the eluate (Boyd 1973; Lin et al. 1971; Shukla et al. 1977). The limit stated in the Ph. Eur. has been 20 ppm, which was based on the formerly used large columns. The Ph. Eur. is recommending a colorimetric test using chromazurol-S for quantification (Feigl 1958). Eluates of fission 99Mo generators were analyzed by atomic absorption spectroscopy for identification of trace amounts of chemical impurities (Hammermaier et al. 1986). Certain chemical impurities have been shown to reduce the labeling yield and alter the in vivo distribution of radioactivity (Boyd 1973; Lin et al. 1971; Ponto et al. 1987).
5.3.4 pH of Eluate The Ph. Eur. permits a pH range between 4.0 and 8.0.
5.4 Methods and Results Care should be taken that generators are eluted regularly and completely. The volume of the eluate and total activity are recorded with the date and time of elution.
5.4.1 Determination of the Elution Efficiency It is accepted that the activity stated on the generator refers to the time of calibration; however, due to precalibration the actual amount of 99mTc activity at delivery might be considerably higher (up to ten times). The high activity load and long intervals between production and delivery of the generator result in a build up of 99Tc carrier, which is coeluted with 99mTc and affects labeling. Therefore, radiopharmacies perform a test elution of the generator upon receipt from the manufacturer as part of the quality assurance program (Nordic Council on Medicines 1989). This ªprimary eluateº is not used for patient studies, but serves to remove 99Tc carrier and to demonstrate the generator function: · Calculate the elution efficiency · Determine the 99Mo content of the eluate
5.4.2 Determination of the
99
Mo Content of the Eluate
The primary eluate is allowed to decay for 5 days, so that the 99mTc activity does not interfere with the measurement of trace amounts of radionuclidic impurities. Measurements of the primary eluate were performed over an energy range of 35 keV to 2.0 MeV, using a Ge(Li)-detector connected to a 4,096-channel pulse-height analyzer;
87
88
5.4 Methods and Results
the acquired spectral data were analyzed by computer. Energy calibrations and efficiency determinations had been performed with standard solutions of several radionuclides (standard mixture). The activity peak at an energy of 740 keV (99Mo) was expressed as nanocuries of 99Mo contamination in the primary eluate at the time of elution (corrected for 99Mo decay). Example of calculation: Primary eluate obtained: Total activity eluted: Elution efficiency: Date of measurement of 99Mo: Time elapsed since elution: Measured 99Mo activity: Amount (corrected for decay): 99 Mo impurity in primary eluate:
11 May, 9:00 hours 402.2 mCi in 11.3 ml 84.6% 16 May, 13:00 hours 124 h (f = 3.68) 293 nCi 1.078 nCi/402.2 mCi/11.3 ml 2.68 nCi/mCi (2.68 ´ 10±4%) 95.4 nCi/ml (3.53 kBq/ml)
Since the limit of 99Mo contamination is 10±1% (1 lCi/mCi) of the total 99mTc activity (Ph. Eur.), the measured 99Mo contamination is acceptable. Table 5.6 presents the results obtained with 140 generators from two different manufacturers; shown are the elution efficiencies and the 99Mo activity in the first eluate, expressed as 10±4% of the 99mTc activity and also as kilobecquerel per milliliter. Other radionuclidic impurities stated in the Ph. Eur. were also determined. I-131 was detected in very small amounts; Ru-103 was not detectable in most eluates. Generators from one manufacturer were an exception, showing 0.27 nCi/mCi of I-131, and values between 0.012 and 0.069 nCi/mCi of Ru-103 (Hammermaier et al. 1986).
Table 5.6. Elution efficiency and
99
Mo impurity
Primary eluate Volume (mL)
Elution efficiency (%)
Mo-99 Activity (10±4%)
(kBq/mL)
Generator Number of samples Range Mean Ô SD Median
68 11.0±13.2 12.76 Ô 0.34 12.8
72 64.2±86.4 74.75 Ô 4.15 74.6
68 1.52±14.7 6.38 Ô 2.84 5.58
65 2.04±27.64 8.20 Ô 4.25 6.95
Generator II Number of samples Range Mean Ô SD Median
68 8.7±10.8 9.63 Ô 0.57 9.55
68 72.1±97.5 80.6 Ô 6.99 79.4
68 0.01±6.93 2.35 Ô 1.99 2.17
68 0.01±11.69 4.03 Ô 3.42 3.58
Chapter 5 Performance and Quality Control of the
99
Mo/99mTc Generator
5.4.3 Determination of the Radiochemical Purity of the Eluate In the Ph. Eur., sodium pertechnetate [99mTc] and other 99mTc species are analyzed by descending paper chromatography (Council of Europe 1997 a). The solvent used consists of eight parts of methanol and two parts of water. The chromatogram is developed for 2 h, dried, and the distribution of radioactivity is measured with a suitable detector. Not less than 95% of the recovered radioactivity is located in the spot corresponding to pertechnetate ion, which has an Rf value of approximately 0.6. Reduced, colloidal forms remain at the start of the chromatogram. In the laboratory, ascending thin-layer chromatography on silica gel glass fiber sheets is used for analysis (Brandau et al. 1996). Acetone is recommended as solvent. Sodium pertechnetate [99mTc] migrates with the solvent front (Rf = 1.0). Reduced, hydrolized activity is analyzed in saline (Rf = 0). Analysis of generators from seven manufacturers used in nuclear medicine showed high radiochemical purity of the eluates, between 99.5 and 100.0% (Hammermaier et al. 1985).
5.4.4 Determination of the Chemical Purity of the Eluate Aluminum cations in the eluate may cause a low labeling yield and affect the biodistribution of 99mTc radiopharmaceuticals. Interference has been reported with aluminum levels below the permitted concentrations (Ponto et al. 1987). The limit specified in the Ph. Eur. was reduced to 10 lg/ml, in analogy to Al3+ concentrations stated in the United States Pharmacopeia, which must not exceed 10 lg/ml (United States Pharm. Convention 2005). A modified quinalizarin-based spot test is used for colorimetric evaluation of eluates against a known standard dilution. Eluates of fission 99Mo generators were analyzed by atomic absorption spectroscopy. Hammermaier et al. (1986) reported data below the detection limit of 1 lg of aluminum per milliliter of eluate. A more recent study presented a comparison between the two methods and showed that with the colorimetric test concentrations of Al3+ below 10 ppm were not detectable (Table 5.7; Marengo et al. 1999). Table 5.7. Summary of quality control of
99m
Tc eluates (Marengo et al. 1999)
99 Mo (10±4%)
103
Ru (10±8%)
Al3+ (ppm)
pH
2.37
9.19
< 10
4.3±7.0
TcO±4
99.64
Volume (ml)
99m
Tc activity
50%
95%
1.56
4.27
89
90
Appendix
5.5 Conclusions Generator function and the purity of 99mTc eluates of the available fission 99Mo generators in Europe have been investigated by several European research institutions over the years. Much information on the benefits of improved technology has been documented, testifying to high standards of manufacturing and to the reliability of validation processes implemented by the regulatory agencies for safe application of the 99 Mo/99mTc generator in nuclear medicine. Several European centers were engaged in implementing GMP standards for the preparation of 99mTc radiopharmaceuticals in nuclear medicine, and thus have contributed to establish a protocol for analytical procedures, which can validate the performance of generator systems from different manufacturers and assure the quality of short-lived generator eluates. The protocol is presented in Appendix A1 of this chapter.
Acknowledgments The Preparation and Quality Control of Tc-99m pharmaceuticals was supported by the Austrian Ministry of Science and Research as a collaboration between the Dept. of Nuclear Medicine, AKH, in Vienna, Austria and the National Institute of Pharmacy in Budapest, Hungary. Part of this manuscript was translated from German by Dr. P. O. Bremer; his contribution is gratefully acknowledged.
Appendix A1 Protocol for the Quality Control of
99
Mo/99mTc Generator Systems
Multicenter studies were performed in Italy between the Depts. of Nuclear Medicine and Medical Physics in Bologna, Cesena, Ferrara, Genova, Milano, Pavia, and Reggio Emilia; and in Austria and Hungary between the Dept. of Nuclear Medicine, AKHWien, Vienna, and the National Institute of Pharmacy, Budapest. Quality assessment included approximately 250 generators from seven suppliers in Italy, and 150 generators from two commercial sources in Austria. The protocol concerns the performance of the generator system and the analysis of the eluate according to the requirements of the Ph. Eur. 1. Performance of the generator system First elution upon shipment of generator ± analysis of primary eluate Elution characteristics: · Elution efficiency (standard elution, percent of nominal activity) · Elution profile (fractional elution, each fraction as percent of sum of activities) · Elution volume containing 50% resp. 95% of activity · Radioactive concentration of eluate (MBq/ml)
Chapter 5 Performance and Quality Control of the
2. Purity of generator eluate (Ph. Eur.) Radionuclidic impurities in primary eluate: Radiochemical purity: Chemical purity: pH value:
99
Mo/99mTc Generator
< 0.1% 99Mo of total activity > 95% 99mTc-pertechnetate ion < 10 ppm ionic aluminum 4.0±8.0
Elution of the generator is performed using aseptic techniques and special, evacuated, sterile vials. To facilitate determination of the volume of eluate, graduated vials are used. The vial is placed into the dose calibrator and the radioactivity is recorded. Each vial containing 99mTc-pertechnetate injection solution must have a radioactive label with relevant information: · Name of radionuclide and chemical name: 99mTc-pertechnetate i.v. · Date and time of elution: 06/13/05, 8:10 hours · Activity of eluate: 6.62 GBq (179 mCi) · Volume of eluate: 8.5 ml · Activity concentration: 778 MBq/ml (21.0 mCi/ml) · Expiration: 6 h A2 Calculation of the Specific Activity of [99mTc]Technetium The specific activity of a radionuclide relates activity (A) (the number of radioactive atoms decaying) to the total number (N) or total mass of atoms present: A=N k Since there are 6.023 ´ 1023 atoms in one gram ´ atom (mole) of the radionuclide, specific radioactivity may be expressed according to the equation: A
dps=gram kN
6:023 1023 atoms k
sec M
g
1 Ci=g
6:023 1023 k
sec Atomic weight 3:7 1010
Curie=g
1:628 1013 k
sec Atomic weight
where N
g
1 gram
6:023 1023 atoms M
g 6:023 1023 Atomic weight
1 Curie 3:7 1010 dps
91
92
Appendix
Example: Technetium-99m (M = 99) T1/2 = 6 hr;
k=
0:693 , therefore: T1=2
k(s) = 0.693/6´60 ´ 60
1 Ci = 37 GBq; 1 GBq = 2.7 ´ 10±2 Ci Ci=g
1:628 1013 0:693 6 60 60 99
Ci=g
1:139 1011 2:16 104
Ci=g
5:27 106
GBq=g 1:95 108 The specific activity of carrier-free technetium-99m is 5.27 ´ 106 Ci/g (mCi/mg, lCi/lg). Consequently, 1 Ci (mCi, lCi) of carrier-free technetium-99m has a weight (mass) of 1.90 ´ 10±7 g (mg, lg). Upon daily elution of the generator (24-h interval), the eluate contains 99mTc + 99Tc corresponding to a mass of 6.9 ´ 10±7 g/Ci (37 GBq). However, longer intervals (> 2 days) result in a considerable increase in 99Tc carrier; if a generator has not been eluted for 3 days, the eluate on day 4 contains 3.64 times more carrier corresponding to 25.15 ´ 10±7 g/Ci (37 GBq).
References Barnes RK, Boyd RE (1982) The chromatographic extraction and purification of 99Mo from uranium solutions by use of a silver impregnated alumina stationary phase. Int J Appl Radiat Isot 33:479±481 Bonnyman J (1983) Effect of milking efficiency on Tc-99 content of Tc-99m derived from Tc-99m generators. Int J Appl Radiat Isot 34:901±906 Boyd RE (1973) Recent developments in generators of 99mTc (IAEA-SM-171/94) In: Radiopharmaceuticals & labelled compounds 1973. IAEA Vienna, pp 3±26 Boyd RE (1982) Technetium-99m generators ± the available options. Int J Appl Radiat Isot 33:801± 810 Boyd RE, Hetherington ELR, Moore PW (1985) Radionuclide generator technology. In: Radiopharmaceuticals & labelled compounds 1984. IAEA Vienna, 79±94 Brandau W, Hotze L-A, Meyer G-J (1996) Radiochemie. In: Bçll U, Schicha H, Biersack H-J, Knapp WH, Reiners Chr, Schober O (eds) Nuklearmedizin [in German]. Georg Thieme, Stuttgart, pp 79±113 Briner WH, Harris CC (1974) Radionuclide contamination of eluates from fission-product molybdenum-technetium generators. J Nucl Med 15:466±467 Council of Europe (2005 a) Sodium pertechnetate[99mTc] injection (fission). Monograph No. 124. European Pharmacopoeia, 5th edn., Maisonneuve, Sainte-Ruffine Council of Europe (2005 b) Sodium pertechnetate[99mTc] injection (nonfission). Monograph No. 283. European Pharmacopoeia, 5th edn. Maisonneuve, Sainte-Ruffine Eckelman WC, Coursey BM (1982) Technetium-99m: generators, chemistry and preparation of radiopharmaceuticals. Int J Appl Radiat Isot 33:793±890 Feigl F (1958) Spot tests in inorganic analysis, 5th edn. Elsevier, Amsterdam, p. 145 Hammermaier A, Reich E, Endrulat HJ, Bægl W (1985) Investigations on the quality of eluates from seven fission Mo-99/Tc-99m-generators. Institute for Radiation Hygiene of the Federal Health Office, Neuherberg, Germany. ISH Report 64.
Chapter 5 Performance and Quality Control of the
99
Mo/99mTc Generator
Hammermaier A, Reich E, Bægl W (1986) Chemical, radiochemical, and radionuclidic purity of eluates from different commercial fission 99Mo/99mTc generators. Eur J Nucl Med 12:41±46 Lin MS, McGregor RD, Yano Y (1971) Ionic aluminium (III) in generator eluate as an erythrocyteagglutinating agent. J Nucl Med 12:297±299 Marengo M, Aprile C, Bagnara C, Bolzati C, Bonada C, Candini G, Casati R, Civollani S, Colombo FR, Compagnone G, Del Dottore F, Di Guglielmo E, Ferretti PP, Lazzari S, Minoia C, Pancaldi D, Ronchi A, Sanita di Toppi G, Saponaro R, Torregiani T, Uccelli L, Vecchi F, Piffanelli A (1999) Quality control of 99Mo/99mTc-generators: results of a survey of the radiopharmacy working group of the Italian Association of Nuclear Medicine (AIMN) Nucl Med Commun 20:1077±1084 Molinski VJ (1982) A review of 99mTc-generator technology. Int J Appl Radiat Isot 33:811±820 Nordic Council on Medicines (1989) Nordic guidelines. Radiopharmacy ± preparation and control of radiopharmaceuticals in hospitals. NLN Publication No. 26, Uppsala Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radio-pharmaceutical formulation problems. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 270±274 Richards P (1966) Nuclide generators. In: Radioactive pharmaceuticals. USAEC Symposium Series, No. 6, (CONF-651111). Oak Ridge, Tennessee, pp 155±163 Richards P, O'Brien MJ (1969) Rapid determination of 99Mo in separated 99mTc. J Nucl Med 10:517 Richards P, Tucker WD, Srivastava SC (1982) Technetium-99m: an historical perspective. Int J Appl Radiat Isot 33:793±800 Robson J (1972) Process for the production of technetium-99m from neutron irradiated molybdenum trioxide ± assigned to the AAEC patents: UK (40273/72), USA (284,868), Sweden (10868/ 72), Japan (85901/1972) Shukla SK, Manni GB, Cipriani C (1977) Effect of aluminium impurities in the generator-produced pertechnetate-99m ion on thyroid scintigrams. Eur J Nucl Med 2:137±141 United States Pharmacopeial Convention (2005) Official monographs: USP 28, sodium pertechnetate Tc99m injection. United States pharmacopeia (USP) 28 ± national formulary (NF) 23, p 1861
93
Chapter 6
Preparation of Technetium
99m
Tc Pharmaceuticals
6
J. Mallol and I. Zolle
6.1 Introduction Technetium-99m (99mTc) is widely used in radiopharmaceutical preparations due to its excellent physical and chemical properties. In fact, more than 80% of all radiopharmaceuticals used in diagnostic nuclear medicine are based on this short-lived radionuclide, which is obtained by elution of a 99Mo/99mTc generator system that is available in any radiopharmacy and nuclear medicine facility.
6.1.1 Physical Characteristics 99m Tc decays with a half-life of 6 h by isomeric transition and emission of 140.5-keV gamma radiation. Large amounts of radioactivity may be used with the single-photon emission computed tomography (SPECT) technology, producing high-contrast images with the gamma camera. In fact, the energy window of the gamma camera is optimized to 140.5 keV (110±220 keV).
6.1.2 Chemical Characteristics 99m
Tc is eluted from the generator as a pertechnetate anion. It has been demonstrated that heptavalent technetium must be reduced to a lower valency state in order to be chemically reactive for labeling. Most 99mTc pharmaceuticals comprise complexes of 99m Tc at various oxidation states (I±V). The preparation of 99mTc pharmaceuticals is greatly facilitated by the availability of commercial cold kits containing the chemical ingredients as a lyophilized formulation ready for labeling with 99mTc-pertechnetate.
6.2 Kit Preparations The preparation of any 99mTc pharmaceutical is performed by using a commercial cold kit and adding the required 99mTc activity in a certain volume of 99mTc eluate (pertechnetate). Kits offer convenience and ease of preparation for ad hoc labeling. Cold kits are considered as semimanufactured products, which need marketing authorization as medicinal products (European Economic Community 1998). Cold kits are commonly produced at the industrial level. The preparation of a 99mTc pharmaceutical by a nuclear medicine facility or a nuclear pharmacy by adding 99mTc eluate to an
96
6.2 Kit Preparations
approved cold kit according to the instructions given by the producer does not need a specific authorization (Nordic Council on Medicines 1998). The labeling procedure is termed as ªreconstitution of the kitº, which may be interpreted as preparation of an official formula as described in the European regulations (Cox 1993). Similarly, 99mTc pharmaceuticals described in the European Pharmacopeia in specific monographs (Council of Europe 2005), as well as the preparation of any medicinal product according to pharmacopeia specifications, is conceptually an official formula.
6.2.1 General Considerations The concept reconstitution of a kit is erroneous, because radiolabeling is an active process by which a new chemical compound (a 99mTc pharmaceutical) is formed involving chemical reactions, in any case the reduction of pertechnetate, and in most cases complex formation, which might need heating in a boiling water bath. Moreover, a kit may be perfectly reconstituted (dissolved) but labeling might be inadequate. Preparation of 99mTc radiopharmaceuticals by using aseptic techniques has to comply with the regulations issued in the Good Manufacturing Practice Guidelines ([GMP] European Economic Community 1997; European Free Trade Agreement 1992). Labeling by a closed procedure is defined as a procedure whereby a sterile radiopharmaceutical is prepared by the addition of sterile ingredients to a presterilized closed container via a system closed to the atmosphere (Lazarus 1994). 99m Tc eluate is added to the sterile vial (kit) with a syringe through the rubber stopper. An excess of pressure in the vial is avoided by withdrawing an equal volume of gas with the same syringe. A breather needle should not be used because oxygen may affect the stability of the radiopharmaceutical, and may cause microbial contamination. The instructions given by the manufacturer of the kit should be strictly followed, particularly with respect to the maximum activity and volume of 99mTc eluate that is transferred to the kit for labeling. The labeled product is a sterile, pyrogen-free solution suitable for intravenous injection. Any abnormality observed by visual inspection of the injection solution is a cause to reject the preparation. 99mTc radiopharmaceuticals have a short shelf-life (generally 6 h); they are used right after preparation.
6.2.2 Cold Kits Cold kits are prepacked sets of sterile ingredients designed for the preparation of a specific radiopharmaceutical. Kits are fully tested to verify the specific characteristics, which are guaranteed by the producer. A kit contains the active ingredient, a reducing agent, and may contain authorized excipients and additives, such as antimicrobial agents, antioxidants, buffer, a nitrogen atmosphere, etc. The active ingredient is the compound to be labeled with the radionuclide. The reducing agent is responsible for the reduction of pertechnetate to a lower valency state; it is considered an essential material. Without reduction, there is no labeling reaction. In fact, the stability of kits had been of considerable concern until freeze-drying was applied to kit production. Exact filling of the sterilized vials is performed automatically by a sterile dispensing/stoppering device, whereby a certain volume (1 ml) of the kit formulation is delivered and subjected to lyophilization. When closing the vial, nitro-
Chapter 6 Preparation of Technetium
99m
Tc Pharmaceuticals
gen gas is introduced through a sterile filter. By this computer-assisted automatic filling device with subsequent lyophilization, kit contents are stable for long periods; additionally, oxidative processes no longer affect the labeling yield. The shelf-life of kits is usually in excess of 1 year. It is important that kits are stored according to the specific conditions (temperature, humidity) indicated on the package, since radiolabeling depends on the integrity of the reducing agent. Cold kits may also be prepared in a radiopharmacy similar to other medicinal products prepared in a pharmacy. The radiopharmacist then functions as the qualified person responsible for preparation of an official formula (formulation, pharmaceutical requirements, stability, etc.)
6.2.3
99m
Tc-Pertechnetate
The 99mTc eluate used for radiolabeling must comply with the specifications stated in the pharmacopeia. Additionally, the specific activity (activity/Tc carrier) and the activity concentration (activity/ml) should be known. Since the specific activity of the 99mTc eluate is related to the time elapsed between elutions, daily elution of the generator at an interval of 24 h will produce eluates with the best quality. Kits are compatible with eluates from different commercial generators; however, high specific activity is mandatory with some kits, especially when labeling biomolecules. The total 99mTc activity and the volume injected into the vial (kit) should comply with the recommendations by the manufacturer. Dilutions should be performed with isotonic saline.
6.2.4 Incubation After dissolving the lyophilisate in the added volume, incubation is an essential step to obtain the radiolabeled medicinal product. In this phase, the chemical reactions take place, resulting in 99mTc labeling. If incubation is inadequate, the labeling reaction may not be completed, and the radiopharmaceutical may not be suitable for administration. Each kit requires specific incubation conditions, but in general, this process is carried out at room temperature in a clean area. In certain cases, the incubation must be performed in a boiling water bath; in such cases it is necessary to operate carefully. Incubation is normally performed with occasional agitation of the shielded reaction vial.
6.2.5 Quality Control Quality is directly related to the labeling yield, which is measured by the amount of unbound 99mTc activity. Limits of radiochemical impurities are stated in the official monographs (Council of Europe 2005). The determination of the radiochemical purity lies in the responsibility of the user (Theobald 1994). To assure safety and efficacy of a 99mTc radiopharmaceutical, the product should be tested regularly, in certain cases before application to the patient.
97
98
References
Radiochemical purity is analyzed by thin-layer chromatography, described in this book. Poor quality of a radiopharmaceutical would affect the clinical information and cause unnecessary radiation exposure of a patient.
6.2.6 Dispensing Dispensing is the compliance of a prescribed medicinal product with the required quality standards (Lazarus 1994). For dispensing a prescribed amount of radioactivity, it is necessary to determine the total radioactivity and the radioactivity concentration of the radiopharmaceutical. A single dose may be withdrawn aseptically from the multidose vial by using a suitable syringe; each syringe must be measured in the dose calibrator to verify the prescribed amount of radioactivity for a patient. Syringes with individual doses of the radiopharmaceutical may be prepared in advance. In this case, the correct identification of each syringe is mandatory, stating on the label: · Identification of patient (name and/or number) · Name of the radiopharmaceutical · Amount of radioactivity and time of preparation · Relevant comments (storage, cautions, etc.) · Name of dispenser, if necessary
References Cox PH (1993) EEC Directives and guidelines applicable to radiopharmaceuticals. Eur J Nucl Med 20:712±715 Council of Europe (2005) European pharmacopeia, 5th edn. Maisonneuve, Paris European Economic Community (1997) Pharmaceutical legislation for medicinal products for human and veterinary use in the European Union. Good manufacturing practices. (Directive 91/ 356/EEC). Eudralex, vol. IV. European Economic Community, Luxembourg European Economic Community (1998) Notice to applicants for marketing authorization for medicinal products for human use in the European Union, Volume IIA (III/3567/92) European Free Trade Agreement (1992) Guide to good manufacturing practice for pharmaceutical products, the convention for the mutual recognition of inspections in respect of the manufacture of pharmaceutical products, Document 5/92 (PIC guidelines on GMP). Lazarus CR (1994) Techniques for dispensing of radiopharmaceuticals. In: Sampson CB (ed) Textbook of radiopharmacy, theory and practice, 2nd enlarged edn. Gordon and Breach, Philadelphia, pp 59±68 Nordic Council on Medicines (1989) Radiopharmacy: preparation and control of radiopharmaceuticals in hospitals. National Library of Norway (NLN) publication No. 26, Uppsala Theobald AE (1994) Quality control of radiopharmaceuticals. In: Sampson CB (ed) Textbook of radiopharmacy: theory and practice, 2nd enlarged edn. Gordon and Breach, Philadelphia, pp 103±125
Chapter 7
Lyophilization Technique for Preparing Radiopharmaceutical Kits
7
E. Chiotellis Freeze-drying, or lyophilization, is the drying of frozen materials by sublimation, i.e., the direct transition from the frozen state into vapor, without any intermediate liquid phase (Neuman et al 1962). The lyophilization technique is the most common method for preparing radiopharmaceutical kits with a prolonged shelf-life. Most radiopharmaceutical kits available today are technetium-99m compounds, while a limited number involves indium-113m complexes. Few kits are also used for the preparation of iodine-123 radiopharmaceuticals.
7.1 History of the Lyophilization Technique The freeze-drying process was applied for first time in 1890 by the Leipzig anatomist Altmann. He froze samples of tissue required for microscopic investigations at very low temperatures. Then, the tissues were placed in a desiccator filled with sulfuric acid and cooled on the outside. The air was evacuated while the tissues remained frozen and the water yielded to the sulfuric acid by sublimation. In this way, Altmann obtained anhydrous tissue preparations, without any shrinkage of the cells. Twenty years later, Shackell demonstrated that the freeze-drying method could be used with very good results for the investigation of easily destructible sensitive compounds in animal and human organs. At the same time, Hammer and Rogers (in 1911 and 1914) demonstrated that suspensions of bacteria may be dehydrated by the freezedrying technique, without being destroyed. In the years that followed until 1930, many experiments were performed on sensitive proteins that lose their biological properties with other drying methods. It was found that they could be retained in their original native form if subjected to freeze-drying. Numerous products such as blood plasma, enzyme preparations, and sensitive drugs were examined and found unchanged by this particular dehydration method. In 1939 the term ªlyophileº was used for the first time by Reichel, Masucci, and Boye for characterization of products obtained by this particular process of dehydration. Up to World War II, the lyophilization technique was used only on a laboratory scale. The sudden increase of demands in freeze-dried blood plasma resulted in its application on an industrial scale. In the first post±war years, the freeze-drying method was applied to various antibiotics, and very quickly became a valuable method of preserving medicinal products. In the years that have passed, a remarkable progress on both technical and physical aspects of freeze-drying was performed, and safe and reproducible methods required for industrial application have been established.
100
7.2 Principles of Lyophilization
7.2 Principles of Lyophilization Lyophilization is a high-technology method of preserving chemicals or sensitive biological materials from humidity: enzymes, hormones, vitamins, blood products, antibiotics, drugs, radiopharmaceutical kits, etc. Lyophilized products are characterized by prolonged shelf-life, and chemical bacteria or enzymatic changes do not easily occur. The sterility is more guaranteed and solubility assured. In addition, transportation is easier. Finally, certain compounds or radiopharmaceutical kits exist only as lyophilized products. However, freeze-dried products suffer from certain disadvantages. The reentry of moisture may destroy the products. Direct optical control of lyophilized products cannot be performed. Therefore, the risk of particle contamination of the final product is high. Bacterial contamination can only be avoided by using the proper installations (clean rooms) for manufacturing injectable lyophilized products. The lyophilization method is similar to ordinary vacuum distillation with one essential difference: the material to be dried must first be solidly frozen and then subjected to a very low absolute pressure (high vacuum) and controlled heat input. Under these conditions, the water content, in the form of an ice matrix, is selectively removed via sublimation, completely bypassing the intermediate liquid phase. The solid particles are locked into the matrix during drying and cannot interact. The following conditions are necessary for freeze-drying: 1. The product must be solidly frozen, usually below its eutectic point (±10 to ±50 8C). 2. A condensing surface must be provided (±40 to ±50 8C) for trapping ice vapors. 3. A powerful evacuating system must be provided, capable of evacuating to an absolute pressure between 5 and 25 mHg. 4. A thermostatically controlled heating source is necessary for heat input to the product. The heat drives the water from the solid to the vapor state (heat of sublimation). Time of drying depends on the nature and volume of the product. Drying temperatures vary and depend on each individual product. Compounds sensitive to heat are dried at low temperatures. From experience, most radiopharmaceutical kits dried at 4±10 8C result in final products of good quality. For example, a batch of 1000 vials (volume = 2 ml) requires a 24-h primary drying cycle (4±10 8C), followed by another 24-h secondary drying cycle. In some kits sensitive to heat, like dimercaptosuccinic acid (DMS) (V), low drying temperatures are required (0 8C). The whole principle of the freeze-drying process depends on the fact that water at temperatures below 0 8C immediately transforms from the solid state of aggregation into the vaporous state. In other words, the technique is based on the sublimation properties of water. Beyond 0 8C, ice melts and another phenomenon, evaporation, takes place. Melting during the freeze-drying process may destroy the product and should be avoided (back melting). About 700 kcal (2,777 BTU) of energy is required for the sublimation of 1 kg of ice. This amount of heat must be brought into contact with the frozen material from the outside in such a way that there is absolutely no danger of the material having time to thaw.
Chapter 7 Lyophilization Technique for Preparing Radiopharmaceutical Kits
The same amount of heat that is required in the drying chamber for the sublimation of the water is subsequently liberated as the water vapor condenses at the ice condenser, and must be removed by means of refrigeration units. Therefore, three basic conditions have to be fulfilled in order to carry out the freeze-drying process: 1. The temperature of the material must be regulated in such a way that on one hand, thawing is avoided, and on the other hand, vapor pressure above the material does not sink due to overcooling. 2. The water vapor molecules escaping from the frozen material should be removed in such way that saturation of vapor pressure above the substance to be dried is avoided. 3. The process should take place in a vacuum so that removal of water molecules may not be impeded by the presence of residual gases.
7.3 Apparatus for Freeze-Drying In constructing any freeze-drying apparatus, care should be taken to obtain optimum values of all the above-mentioned conditions. A freeze-drying plant should contain a drying chamber, an ice condenser, a refrigeration unit, and a vacuum pump.
7.3.1 The Drying Chamber This chamber is a vacuum-tight container in which the material to be dried is placed. There are practically no limits to the dimensions and shape of the drying chamber. Rack surfaces either heated or cooled are provided for the reception of material to be dried (ampoules, vials, dishes, liquid, or solid drying substances).
7.3.2 The Ice Condenser The ice condenser is a pipe coil system or in the case of smaller apparatus, a cold trap, fitted in a vacuum-tight container, which is connected to the drying chamber. In smaller laboratory devices, the ice condenser is normally cooled by means of carbon dioxide or liquid nitrogen, while in larger plants, by refrigeration units.
7.3.3 The Refrigeration Unit During the freeze-drying process, the water contained in the material passes three states of aggregation. The product should be cooled, frozen, and then subjected to the sublimation stage. During this stage, heat must be applied to the material to compensate for the sublimation cold developed. This performance is regulated by the refrigeration unit.
101
102
References
7.3.4 The Vacuum Pump The vacuum pump keeps both chamber and ice condenser sufficiently free from residual gases so that the water vapor is able to flow unimpeded from the drying material process. In practice, the freeze-drying process of solutions proceeds as following: 1. The bulk solution is dispensed into the vial from a 0.5 to 2.5 cm height. The amount of solution in the vial is very important for efficient drying. The vials are loosely capped with the special rubber stoppers, and then are put into the vacuum chamber. 2. The vials with the product are gradually frozen below the eutectic point of the solution (usually ±30 to ±40 8C). 3. The condenser is turned on, and the condenser indicator is observed until it reaches its maximum value (usually ±50 8C). 4. At this point, the vacuum pump is turned on, and vacuum is applied to the chamber until the lowest value of vacuum is obtained (usually 10±20 mHg). 5. Heat is then applied to the product through a controlled heating±cooling system. The heat facilitates the sublimation process (heat of sublimation). This step of freeze-drying is the primary drying cycle, and the temperature, the drying temperature. The point at which the temperature indicator reaches the preset temperature is theoretically considered the end of the freeze-drying process. 6. A secondary drying cycle, ranging in time, is usually applied so that the complete absence of humidity from the product is assured. 7. After completion of drying cycles, the product is closed with a stopper in the vacuum chamber under either a low-vacuum or nitrogen atmosphere. The stoppering device could be pneumatic or mechanical, depending on the specifications of the freeze-drying plant. Apart from the high cost, the freeze-drying technique remains an excellent and almost unique method for preserving a variety of compounds, among which are valuable medicinal products sensitive to humidity.
References Neumann K, Koln P (1962) Freeze drying. A modern application of refrigeration. Rep Science Technol, pp 45±53 Nail SN, Catlin LA (1985) Advances in control of production freeze-dryers. J Parenter Sci Technol 39:16±27 Pyle HAA, Eilenberg H (1971) Continuous freeze drying. Vacuum 21:103±114#
Chapter 8
Cellular Labeling with 99mTc Chelates: Relevance of In Vitro and In Vivo Viability Testing
8
H. Sinzinger and M. Rodrigues
8.1 Introduction Labeling of blood cells has gained importance as routine procedure in nuclear medicine. A variety of different blood cells such as red blood cells (RBC), platelets, and white blood cells ([WBC] neutrophils, lymphocytes and monocytes and recently stem cells) can be radiolabeled and applied for diagnosis and therapeutic monitoring in specific disease states. In order to label specific cell types, the separation of that particular type of cell must be carefully performed. Two main categories of cell labeling have been used, cohort and random population labeling. In cohort labeling, the label binds to marrow precursors, which appear after a few days as a labeled cell population of uniform age in the circulation, enabling the study of the cells during their life span. Cohort labeling is useful for the study of cell production rates and survival. In random labeling, the circulating cell population (of all ages) is uniformly labeled, allowing mean life span determination. Random labeling is carried out usually in vitro on a small sample of venous blood. Random labeling methods have been more successfully used than cohort labeling techniques. Accuracy in diagnosis depends largely on the labeling efficiency (LE) of blood cells, which can be affected by many factors. The specificity of the labeling, maintenance of viability, and normal physiological function of the labeled cells, together with sterility, apyrogenicity and radiopharmaceutical purity, and stability have to be carefully controlled. The methods involved in the labeling of blood cells with 99mTc are reviewed and discussed in this overview.
8.2 Red Blood Cells Labeling of RBC is easily facilitated as they are relatively abundant in the blood, easily separated and handled in vitro, not very susceptible to damage from physical or chemical manipulations, not as dependent on energy and nutritional requirements as the other cellular elements in vitro, and have a variety of cellular transport mechanisms and hemoglobin within that is rich in active metal-binding sites (Srivastava and Rao Chervu 1984). Random labeling methods of RBC have been more widely utilized than have cohort labeling techniques. Besides 99mTc, several radionuclides such as 3H, 11C, 14C, 15N, 32P, 51Cr, 55Fe, 59Fe, 67 Ga, 68Ga, and 111In have been evaluated for labeling of RBC. In vivo, in vitro, and in vivo/in vitro techniques have been developed and are presently available for routine use in nuclear medicine (for imaging as well as kinetic studies).
104
8.2 Red Blood Cells
Technetium as pertechnetate is in the + 7 valency state and as such, is not bound firmly to RBC, and moves in and out of the RBC rather freely. In contrast, reduced technetium cannot readily cross the cell membrane (Srivastava and Rao Chervu 1984) and leave the cell, and binds rapidly and irreversibly mainly to the b-chain of the globin part of hemoglobin (Eckleman et al. 1979). Reducing agents thus have to be used for labeling RBC in vivo and in vitro. For in vivo labeling, stannous salts are injected intravenously approximately 15±20 min before injection of 99mTc-pertechnetate. Stannous ions diffuse into the cell, become bound to a cellular component, have a relatively slow clearance (Srivastava and Rao Chervu 1984), and reduce 99mTc when it enters the RBC. The labeling of RBC thus occurs within the intravenous space. Using the in vitro technique, the labeling of RBC is performed in a sterile vial. Most methodologies contact RBC, generally in whole blood, with stannous ions, using a suitable tin (II) preparation (Srivastava and Rao Chervu 1984). In the in vitro technique, stannous ions are injected into the patient, and labeling with 99mTc-pertechnetate of a smaller number of RBC is performed in a closed system (e.g., butterfly needle placed in a peripheral vein). Thereafter, the labeled RBC (in plasma) are reinjected into the patient (Berger and Zaret 1984; Winzelberg et al. 1982). In vivo labeling is more widely used. However, RBC compete for intravenous 99mTc-pertechnetate with the stomach, thyroid, and kidney. In vivo methods thus have frequently variable and irreproducible LE, which is generally lower than that of the in vitro technique. In the in vitro techniques, quality control in order to avoid free 99mTc-pertechnetate and thus, unnecessary radiation exposure to the patient, is performed prior to the injection of 99mTc-RBC. In vitro techniques are therefore the methods of choice when high LE is required as there is almost no free pertechnetate in the patient (Berger and Zaret 1984; Winzelberg et al. 1982). Several parameters are influencing RBC labeling and thus, LE (which is determined by measuring the cell-bound radioactivity as compared with the total radioactivity in percentage) (Table 8.1). Carrying out an in vitro technique the type of anticoagulant used can modify the 99mTc labeling of RBC as well as the 99mTc-RBC distribution. Controversy exists about the effect of the type of anticoagulants that have been used (ethylenediaminetetraacetic acid [EDTA], heparin, acid-citrate-dextrose [ACD], sodium citrate, sodium oxalate and others) for RBC labeling in vitro. LE, in vitro and in vivo stability of the label with EDTA are higher as compared with saline. EDTA reduces the stannous tin content of plasma to a minimum level and assures good labeling yields, which is particularly important with samples of blood with very low hematocrit (Srivastava and Rao Chervu 1984). The use of ACD results in superior RBC labeling relative to heparin (the most utilized methods) (Porter et al. 1983) and 99mTc-RBC/ACD images are superior to those of 99mTc-RBC/heparin (Wilson and Hung 1992). Heparin in the catheter was shown to affect RBC labeling (Hegge et al. 1978). In addition, ACD preserves the cellular function much better than does heparin (Srivastava and Straub 1990). ACD is thus the anticoagulant preferred for preparing in vivo/in vitro 99mTc labeling of RBC. The optimal conditions for RBC labeling, both in vitro and in vivo, evaluated with 99mTc-oxine (1 mCi/ml) and ACD or sodium citrate as anticoagulants, showed that the LE is also dependent on the density of RBC (Fig. 8.1), time (Fig. 8.2), pH (Fig. 8.3), and temperature of incubation (Figs. 8.1±8.4), as well as on the amount of the tracer (Fig. 8.4) (optimal conditions, LE > 95%: 1 ´ 109 RBC/ml, 1 min, pH 5.0± 8.0, 37 8C incubation, and 5 lg oxine/ml) (Reiter et al. 1984). The LE, as well as the localization, of RBC can be markedly influenced by drugs circulating in the plasma and/or diseases, which can affect RBC (the membrane potential, among others) (Table 5.1). In patients who have recently received iodinated contrast
Chapter 8 Cellular Labeling with Table 8.1. Variables influencing red blood cell (RBC) labeling with
99m
Tc Chelates
99m
Tc-pertechnetate
Collection injury Density of RBC Disease (e.g., leukemia, high fibrinogen level, sickle cell disease, other abnormalities of hemoglobin (Riordon and Nelp 1982) RBC antibodies (Leitl et al. 1980) Intravenous canulae Anticoagulant Quantity of stannous ions (II) (Rao et al. 1986) Time delay between ªtinningº of RBC and pertechnetate administration Incubation Medium (e.g., dextrose in water) (Berger and Zaret 1984) pH Temperature Time Speed of centrifugation Drugs or pharmacological interventions (heparin (Berger and Zaret 1984), antimicrobials or antibiotics, anticonvulsants, tranquilizers, anti-inflammatory agents (Chervu et al. 1981; Hladik et al. 1982), nifedipine (Sampson 1993), prazosin, digoxin (Lee 1983), propanolol, hydralazine, methyldopa, verapamil, chlorothiazide, furosemide, ranitidine, iron therapy, etoposide+ doxontbicin (Sampson 1993, 1995), others) Aluminum (Sampson 1995) Iodinated contrast media (Tatum et al. 1983)
Fig. 8.1. Cellular density±dependent labeling efficiency (LE) of red blood cells (RBC)
media, a great reduction of LE (from the normal value of 90% to as low as 30%) can occur, probably due to a change in either stannous ion distribution or redox potential (Tatum et al. 1983). Stannous ions should be injected directly and not through an intravenous canulae, as synthetic material also diminishes LE (Sampson 1995). For evaluation the function of labeled RBC, in vitro and in vivo viability testing have been used. No evidence of morphological alteration of RBC (histological and/or electron microscopic examinations (Fig. 8.5) after 99mTc-labeling was seen.
105
106
8.2 Red Blood Cells
Fig. 8.2. Time-dependent LE of RBC
Fig. 8.3. pH-dependent LE of RBC
Recovery ([REC] i.e., the percentage of injected dose remaining cell bound in the circulation for 60 min) and in vivo biodistribution provide key information about cell integrity and function. Even after several isolation and incubation steps and being exposed to radioactive material, RBC have been shown not to alter their in vivo behavior significantly. Elution of 99mTc from RBC and/or its poor LE is reflected by gastric secretion of 99mTc-pertechnetate and accumulation of free pertechnetate in the thyroid, as well as increased urinary radioactivity. 99m Tc labeling of RBC allows imaging with low-dose radiation to the patient. Applications of 99mTc-RBC are in widespread use clinically (Table 8.2). In particular, 99mTcRBC have greatly contributed to the rapid growth of nuclear cardiology. However, due to the short half-life of 99mTc, serial imaging should be performed up to 12 h after the
Chapter 8 Cellular Labeling with
99m
Tc Chelates
Fig. 8.4. Oxine concentration±dependent LE of RBC
Fig. 8.5. Human RBC after radiolabeling, examined by scanning electron microscopy. No sign of morphological alteration is visible. Perfusion fixation, critical point drying, ´ 1500
107
108
8.3 Platelets Table 8.2. Clinical applications of Normal RBC
Denaturated RBC
99m
Tc-RBC
Cardiovascular procedures hemangiomas Blood pool imaging Vascular malformations Bleeding (GI, cerebral, others), cerebral blood flow stroke Deep vein thrombosis Spleen imaging Splenic infarcts Accessory spleen(s) localization Assessment of splenic function and size Space-occupying disease GI bleeding
GI gastrointestinal
radiolabeling. In addition, a spontaneous elution of the label in vivo of 4±10% per hour occurs (Ferrant et al. 1974). 99mTc-RBC is thus not applicable for studying RBC mass determination and lifespan measurement. For these and other clinical procedures, longer-lived labels (such as 51Cr) are required. For splenic studies (Table 8.2), heat-damaged 99mTc-RBC have to be used, the in vitro technique being the method of choice. High splenic uptake (~ 70%) allows the administration of low activities of the radiotracer (~ 1 mCi), thus reducing the radiation dose to patients considerably (Srivastava and Rao Chervu 1984).
8.3 Platelets Random labeling of platelets has been more successfully employed than cohort labeling. Only autologous platelets are used nowadays. Platelets have to be isolated prior to labeling, as the radiopharmaceuticals presently available for platelet-labeling are nonspecific, labeling other blood cells and some plasma proteins as well (Najean 1986). The centrifugation steps and washing procedures are potentially damaging to platelets, and platelet isolation must thus be carefully performed in order to avoid cellular activation and in vitro damage. Great varieties of methods have been reported for platelet isolation (Bunting et al. 1982; Hawker et al. 1987; Sinzinger et al. 1984). In practice, however, the platelets are isolated from anticoagulated blood by simple differential centrifugation (Najean 1986; Sinzinger et al. 1984). This method allows obtaining platelets in high concentration, maintaining their functional qualities (in terms of viability, cell kinetics, survival, and sequestration sites). Complete separation of platelets from the other blood cells is, however, difficult to obtain. Recently (Sweeney et al. 1995), relatively rapid (average filtration time of 6.6 min) preparation of platelet concentrates with good platelet yields (total platelet concentrates platelet counts averaging 7.8 Ô 1.8 ´ 1010) that are WBC-reduced (WBC count to levels below 7 ´ 105) before storage has been made possible by the introduction of filtration (using a large-capacity filter) of the platelet-richplasma (PRP). Prestorage filtration of PRP and the preparation of filtered platelets did not result in any significant beneficial or adverse effect on subsequent platelet quality. This approach seems thus to be a new and easy means of producing a PRP-derived WBC-reduced platelet concentrate (Sweeney et al. 1995). Various factors influence platelet labeling (Rodrigues and Sinzinger 1994; Table 8.3). Platelet function depends on glycogen as an energy source, glucose being a key sub-
Chapter 8 Cellular Labeling with Table 8.3. Variables influencing platelet labeling with
99m
99m
Tc Chelates
Tc-pertechnetate
Collection injury Density of platelets Anticoagulant Amount of the complex Incubation Medium pH Temperature Time Speed of centrifugation Type of plastic used for bags and tubes Aging (Baldini and Myers 1980) Calcium ions (Becker et al. 1988) Lipids Cholesterol (Granegger et al. 1988; Sinzinger 1987 a) Low-density lipoprotein (LDL) (Granegger et al. 1988; Sinzinger 1987 a) Additives Prostaglandins (Sinzinger 1987 a) Nitric oxide (Wagner et al. 1989) Others
strate for platelet function (Schneider and Gear 1994). The medium used for resuspending the platelet pellet is thus particularly important for the maintenance of the functional properties of platelets. The choice of the anticoagulant is also crucial. Several anticoagulants have been used: heparin (may induce platelet activation and shortens the platelet survival), citrate (lacks dextrose for platelet nutrition), EDTA (may damage platelets), and ACD (pH of 6.5, contains dextrose, increases thus cellular viability). LE of platelets is by far higher with ACD and sodium citrate as compared with EDTA and heparin (Fig. 8.6). Due to the absence of proteins and calcium, incubation of platelets in ACD-saline increases the membrane permeability and further the incorporation of tracers and LE. ACD is thus nowadays the anticoagulant of choice for platelet labeling. During pelleting, platelets may become activated and may become difficult to resuspend, unless activation is inhibited. The simplest way of performing such inhibition is to acidify (to pH 6.2±6.5) the platelet-rich plasma (Lætter et al. 1986). In addition, antiaggregatory prostaglandins (PG), either PGE1 (Hawker et al. 1987) or prostacyclin ([PGI2] 3.33 lg) (Sinzinger et al. 1981), which are protecting platelets from the activating effects of centrifugation and other damage by elevation of cAMP, among others, can be added and are commonly used. The addition of PG affects labeling parameters and in vitro viability testing favorably (Sinzinger et al. 1987a), being especially useful in thrombocytopenia or other rare clinical conditions, to avoid damage of particularly sensitive platelets. PG stabilizes the platelet membrane (Gorman et al. 1977), minimizes artificial damage (Sinzinger et al. 1981, 1987 b), and reduces platelet trapping on the reinjection site (Sinzinger et al. 1981), thereby increasing REC significantly (Sinzinger et al. 1987 a). The duration of the effect of PG on platelets is prolonged, and PG can thus be added to the whole blood once, only at the start of the labeling procedure, without the need to further add the compounds at subsequent steps (of the procedure), even though these may involve platelet washing (Peters et al. 1986). The platelet pellet can then be easily resuspended
109
110
8.3 Platelets
Fig. 8.6. Anticoagulant-dependent LE of platelets
in a small volume of buffer or plasma for labeling (Peters 1988). Nitric oxide (NO), the active compound of the endothelium derived relaxing factor (EDRF), improves the platelet metabolic activity by increasing cGMP, and may increase the REC and facilitate platelet handling (Wagner et al. 1989). It has to be added at a quite late stage after the preparation of the platelet pellet, because hemoglobin inactivates NO. Therefore, extremely high amounts of NO or NO donors (e.g., doses of more than 5±10 mg of molsidomine) per preparation added immediately and repeatedly would be necessary, which are rather expensive and thus unrealistic. Platelet function is better preserved in plasmatic environment and thus viability is superior, and a higher REC is seen when platelets are labeled in plasma as compared with buffer (Thakur et al. 1981). Use of plasma, however, requires longer incubation times to achieve acceptable LE as compared with buffered salt solutions (Scheffel et al. 1979). Keeping the time of incubation of platelets as short as possible is fundamental, as platelet viability due to damaging decreases with time (Mathias and Welch 1979). A closed Monovette technique (Sinzinger et al. 1984) made the techniques of labeling platelets accessible for wide clinical use, even in smaller units, at low costs. This method combines the requirements currently considered as optimal for platelet labeling (i.e., lowest amount of blood [16 ml], shortest ex vivo period of platelets (less than 60 min), and optimal labeling conditions (37 8C, 5 min). Several techniques, radionuclides and tracers (such as 51Cr, 111In [-oxine, -oxine-sulfate, -tropolone, -mercaptopyridine-N-oxide, -acetylacetone, and -chlorotetraphenylporphyrin], 99mTc [-oxine, -hexamethylpropyleneamine oxime {HMPAO} and -phytate] and 123 I-metaiodobenzylguanidine [MIBG]) have been communicated in an attempt to achieve the requirements for optimal in vitro radiolabeling and subsequent in vivo studies. The labeling of platelets with 99mTc is still in its infancy. 99mTc has the advantage of easy storage, low cost, and it shows almost no reutilization. However, it has no specificity of labeling, and the elution rate (for platelet labeling) is high (8% per hour) (Becker et al. 1988 a). Various tracers have been evaluated.
Chapter 8 Cellular Labeling with
99m
Tc Chelates
99m Tc-oxine has proved to be a good platelet label. The mean LE (91%) and REC (71%) data of 99mTc-oxine were found to be comparable to 99mTc-oxine-sulfate and 111 In-oxine (Angelberger et al. 1981). An LE of > 90% was found after an incubation time of only 1 min at 37 8C (Fig. 8.2). 99mTc-oxine and 99mTc-oxine-sulfate, however, are not commercially available. 99m Tc-HMPAO is an interesting platelet-labeling compound, mainly due to its lipophilicity and the good quality images of platelet accumulation over the lifetime of 99m Tc (Peters 1988). However, 99mTc-HMPAO has an LE by far lower, and requires a much longer incubation time than do 99mTc- and 111In-oxine, which favors platelet functional damage. Due to the relatively high elution rate from platelets, a significant gastrointestinal and renal excretion of free 99mTc-pertechnetate occurs (Becker et al. 1988a), which significantly impairs abdominal and pelvic imaging. 99m Tc-phytate again requires a long incubation time (30 min), shows a low LE (20± 50%) and a high elution rate. In addition, divalent cations, such as Ca2+ and Mg2+, in the anticoagulant and the incubation buffer interfere negatively with the labeling (H. Sinzinger, unpublished data). Thus, 99mTc-phytate did not succeed as a platelet label, nor is it commercially available. The viability of platelets following radiolabeling has been evaluated by in vitro tests and by their in vivo distribution. The most commonly used in vitro methods have been testing the response of radiolabeled platelets to aggregating agents (e.g., adenosine diphosphate [ADP] (Sinzinger et al. 1987 a) [Fig. 8.7], collagen, ristocetin, arachidonic acid, PAF, epinephrine (Mathias and Welch 1984; and others), their adhesion to foreign (e.g., vascular) surfaces (Peters 1988), their migration
Fig. 8.7. Aggregation response before (1), during (2) and after (3) the handling of platelets, showing that the platelet function was not impaired as measured by the adenosine diphosphate (ADP)induced aggregation. Inducing agent: ADP (10 lM, 100 ll); Born-type aggregometer; 0.6-ml, platelet-rich plasma samples; platelet concentration: 250 ´ 103/ll. T light transmission (percentage)
111
112
8.3 Platelets
(Sinzinger et al. 1987 a) or histological and/or electron microscopic examination, before the reinjection of the radiolabeled platelets. Other parameters include the release of markers of platelet activation, such as b-thromboglobulin (Towler 1985). Electron microscopy is a sensitive indicator of platelet activation, manifested as pseudopodia formation (Badenhorst et al. 1982; Figs. 8.8 and 8.9). However, all the available in vitro tests failed to predict correctly collection and labeling injury, showing their limited practical value, and take a long time, which results in functional platelet deterioration and excludes their routine application (Sinzinger et al. 1987 a). Labeling-induced injury is also reflected by the in vivo behavior of platelets. Platelets activated and/or damaged during the labeling procedure show an abnormal biodistribution, such as sequestration of radiolabeled platelets in the liver, spleen, and lungs, which results in lower REC in blood and shortened survival. REC is therefore the only reliable viability parameter, as morphologically damaged cells may recover completely after reinjection, while apparently intact ones, in contrast, may not. The normal values for platelet REC range from 55±72% of the injected dose (Baldini and Myers 1980; International Committee for Standardization in Hematology 1988; Mortelmans et al. 1986) due to pooling of about one third of the platelets in the liver and spleen (Baldini and Myers 1980). 99mTc in none of the tracers used until now caused by its own any sign of morphological or functional alteration due to radiation injury. Conclusive microdosimetry data are not yet available. The too-short half-life of 99mTc for platelet survival studies and the high elution rate (instability of cell binding) with the tracers so far examined have limited considerably the clinical use, although with various applications (Table 8.4), of 99mTc-labeled platelets. 111In-oxine is still nowadays the tracer of choice for the studies with radiolabeled platelets, which are long established and have attracted considerable interest.
Fig. 8.8. Human platelets after radiolabeling, examined by scanning electron microscopy. No sign of morphological alteration is visible. Perfusion fixation, critical point drying, ´ 8000
Chapter 8 Cellular Labeling with
99m
Tc Chelates
Fig. 8.9. Human platelets after the radiolabeling procedure, examined by transmission electron microscopy. Almost no signs of platelet activation, manifested as pseudopodia formation. Perfusion fixation, critical point drying, ´ 40 500
Table 8.4. Indications for studies with radiolabeled platelets Kinetic studies Evaluation of the normal platelet kinetics and biodistribution Understanding of the role of platelets, platelet activation and consumption in diseases characterized by thromboembolic phenomena or thrombocytopenia (Baldini and Myers 1980; Lætter et al. 1986; International Committee for Standardization in Hematology 1988; Vallabhajosula et al. 1986) as well as in vascular disorders or endothelial (surface) abnormalities (Baldini and Myers 1980; Vallabhajosula et al. 1986; Harker et al. 1977) Differentiation of the cause of thrombocytopenia Evaluation of the effects of platelet-inhibitor drugs Detection of prethrombotic states (Lætter et al. 1986) Evaluation of the effects of risk factors (Rodrigues and Sinzinger 1884) Evaluation of different cell separation techniques, storage or transfusion of platelets procedures, in transfusion medicine (International Committee for Standardization in Hematology 1988; De Vries et al. 1993; Mollison et al. 1987) Imaging (Rodrigues and Sinzinger 1994) Atherosclerosis Surgical interventions Synthetic material Thrombosis Transplantation
113
114
8.4 White Blood Cells
8.4 White Blood Cells Several methods are available for labeling WBC. Their underlying principles are, however, similar and include isolation of WBC, prevention of cell activation and/or damage, and choice of ligand (Peters et al. 1986). Diverse factors influence the LE of WBC (Table 8.5). Apart from maintenance in plasma (a major factor in the promotion of granulocyte activation is their isolation from plasma), no further additives have been used (Peters et al. 1986) to inhibit granulocytes activation during their isolation and/or labeling procedure. As an anticoagulant, ACD solution is preferred to heparin, because WBC show less tendency to adhere to plasticware with ACD (McAfee et al. 1984). Antibiotics seem to be very unlikely to have a negative influence on LE (Sinzinger and Granegger 1988). WBC cannot be isolated from platelets and RBC by differential centrifugation alone. Random labels are the ones in common use for WBC. Either a mixed WBC suspension or a specific WBC type population, which requires more-sophisticated approaches, can be isolated, depending on the circulating WBC count, and the purpose of the study, while preserving cell viability. Homologous WBC can be used in leukopenic patients and have proven successful (Sinzinger and Granegger 1988). Monocytes are particularly difficult to separate from whole blood because they are normally very few in number, and their viability is affected by the dose of radiation (Fig. 8.10). Lymphocytes are exquisitely sensitive and damaged by radiation (Chisholm and Peters 1980; Chisholm et al. 1979), and very few clinical studies using radiolabeled lymphocytes thus exist. After labeling WBC with 740 MBq of 99mTc-HMPAO, the radiation damage of the lymphocytes due to self-irradiation was estimated to be equivalent to 26 Gy of x-rays. Due to almost complete inhibition of the proliferative capacity at this high dose level, the increased risk for a lymphoid malignancy after administration of isolated lymphocytes or mixed WBC labeled with 99mTc-HMPAO activities sufficient for scintigraphy can, however, be regarded as small (Thierens et al. 1982). An injection of 100 MBq 99mTc-labeled autologous human granulocytes was found to give them an absorbed radiation dose of 1.8 Gy after 25 min and 8.4 Gy after 4 h. In vitro tests revealed no signs of radiation damage to the cells (Skretting et al. 1988).
Table 8.5. Variables influencing white blood cells (WBC) labeling with 99mTc- hexamethylpropyleneamine oxime (HMPAO) Collection injury Density of WBC Anticoagulant Sedimenting agents (type and volume) (Webber et al. 1994) Amount of the complex Time delay between labeling of WBC and administration (HMPAO) Incubation Medium pH Temperature Time Speed of centrifugation Drugs: corticosteroids (Sampson 1995; McAfee et al. 1984), ethanol (McAfee et al. 1984), cyclosporin, azathioprine, ranitidine, nifedipine, procainamide (Sampson 1995), others
Chapter 8 Cellular Labeling with
99m
Tc Chelates
Fig. 8.10. Effect of radiation dose on monocyte viability
Separation of WBC involves the addition of a sedimenting agent (e.g., dextran, methylcellulose, and hydroxyethylstarch) to whole blood (Peters et al. 1986). Laborious cell harvesting techniques include newer density gradients for isopycnic centrifugation (nonionic contrast media), centrifugal elutriation, and flow cytometry, among others (McAfee et al. 1984). Relatively pure populations of granulocytes, lymphocytes, or monocytes can be harvested by elutriation (Berger and Ederson 1979; McAfee et al. 1984), which is, however, rather expensive. Granulocytes or lymphocyte±monocyte isolation can also be performed, achieving a high yield or high purity by isopycnic density centrifugation, such as Percollplasma and metrizamide-plasma density gradients, because of slight differences in cell density (Peters et al. 1986). With the surface adherence method, pure lymphocyte or monocyte populations can also be obtained (McAfee et al. 1984). However, some cell functions are altered by this manipulation (Fisher and Koren 1981). Monocytes and granulocytes may also be isolated by phagocytosis of radioactive particles, followed by density gradient centrifugation or flow through a magnetic field for in vitro experiments, with an LE generally only of 30±40%. However, this approach activates the cells metabolically, resulting in poor in vivo survival (McAfee et al. 1984), and thus is not acceptable for in vivo studies. Several radiotracers such as 32P-, 51Cr-, 125I-, 67Ga-, 68Ga-, and 111In-lipophilic chelates, among others, have been developed for the purpose of labeling WBC. 111In-oxine has become the standard for radiolabeling WBC. However, 99mTc has more favorable dosimetry and energy and many attempts have been made to replace 111In with 99mTc, the use of 99m Tc-compounds for WBC labeling having attracted considerable interest becoming an area of research undergoing much experimentation. Several 99mTc radiopharmaceuticals, such as 99mTc-HMPAO, -albumin colloid, -sulfur colloid, -sestamibi, -teboroxime, -mebrofenin, -disofenin, -gluceptate, -dimercaptosuccinic acid (DMSA) (Segall et al. 1994), -oxine, -phytate (H. Sinzinger, unpublished data) and -pyrophosphate (Uchida et al. 1979) have been tested. HMPAO showed the highest mean LE, 41±56% (Arndt et al.
115
116
8.4 White Blood Cells
1993; Becker et al. 1988b; Danpure et al. 1988; Lantto et al. 1991; Mountford et al. 1990; Roddie et al. 1988) and 79.4% (Segall et al. 1994), as compared with albumin colloid (12.1%, Segall et al. 1994), sulfur colloid (11.7%, McAfee et al. 1984; Segall et al. 1994), sestamibi (11.1%), and teboroxime (5.3±14.2%, Segall et al. 1994). Mebrofenin, disofenin, gluceptate, and DMSA do not label WBC (Segall et al. 1994). Pyrophosphate had a LE of 40±60% and showed poor in vivo recovery of the labeled WBC and poor abscess localization (Uchida et al. 1979). All the other agents have high labeling stability (ranging from 80 to > 95% at 4 h and > 80% at 24 h), except sestamibi, which washed out very rapidly (remaining 52% at 4 h and 5% at 24 h, Segall et al. 1994). 99mTc-oxine had an LE ranging from 50 to > 80%, with 5 min of incubation, while 99mTc-phytate required a long incubation time (30 min), had low LE (20±50 %), and a high elution rate (H. Sinzinger, unpublished data). Attempts were recently made to use 99mTc-ethylcysteinate dimer (ECD) to label WBC (Kao et al. 1994). ECD is a neutral, lipophilic agent, introduced as a new brain perfusion agent. It has a higher radiochemical stability than HMPAO, being stable in vitro for at least 24 h, but it has lower WBC LE, worse stability of labeled WBC, and more rapid elimination than 99mTc- HMPAO from most tissues, thus being not a good choice as a WBC-labeling agent to replace 99mTc-HMPAO (Kao et al. 1994). For assessing radiolabeled WBC viability, in vitro testing before administration to the patient and in vivo distribution of WBC can be performed. The adherence characteristics of WBC are measured in vitro and performed easily, but suffer from a lack of specificity and sensitivity (McAfee et al. 1984). Adherence of WBC is not altered by labeling with HMPAO, while it is decreased by albumin colloid, sestamibi, and teboroxime and increased by sulfur colloid (probably as a result of activation) (Segall et al. 1994). Routine tests of granulocyte function, namely random migration, chemotaxis, Candida killing, phagocytosis, and trypan blue exclusion test, are not sensitive enough to detect abnormalities on the status of the cell function before administration, which profoundly change further in vivo behavior (Peters et al. 1986) and are of limited value, only showing a difference in rather extreme situations. Besides, results of these tests generally are not available until several hours later. Labeled WBC smeared and observed with light microscopy provide a reliable, inexpensive, and quick insight into their purity, structural integrity, and their dispersal (McAfee et al. 1984), but do not replace the other functional tests. Transmission electron microscopy (Fig. 8.11) is expensive and rather time consuming. The most valuable parameter remains the in vivo function of reinjecting the labeled WBC and measuring recovery and in vivo distribution, although too late for consequences if negative. Following injection, normal distribution of labeled WBC includes an initial transitory uptake in the lungs and, later, in the spleen, liver, and bone marrow. The relative amounts of the distribution of each of these sites vary with the labeling procedure used. A disadvantage of 99mTc complexes in general is nonspecific bowel accumulation, which makes their late abdominal imaging difficult. Damage to WBC or cell clumping during and/or because of the labeling procedure produces an abnormal distribution of the labeled WBC. A prolonged and delayed lung transit time and/or an abnormal high liver uptake are ominous signs that some damage of the labeled WBC occurred (Bowring 1986). Damage of lymphocytes by 111In was detected as a failure of recirculation between blood and lymph (Peters et al. 1986). To minimize damage of the specific lymphocyte, activity must be restricted, requiring harvesting of a high number of cells for imaging. HMPAO thus has become the best agent for labeling WBC. It was a radiopharmaceutical introduced for evaluating regional cerebral blood flow and is currently the only 99m Tc-labeling agent for WBC commercially available in most countries. HMPAO is a li-
Chapter 8 Cellular Labeling with
99m
Tc Chelates
Fig. 8.11. Human lymphocyte after radiolabeling, examined by scanning electron microscopy. No sign of morphological alteration is visible. Perfusion fixation, critical point drying, ´ 2000 Table 8.6. Clinical Applications of
99m
Tc-WBC
Inflammatory bowel disease Ulcerative colitis Crohn's disease Localization of sepsis Localization of abscesses Infections after surgery (e.g., grafts, prostheses) Osteomyelitis (Mortelmans et al. 1989) Pneumonia (Raptopoulos et al. 1982) Endocarditis (Sfakianakis et al. 1982 a) WBC accumulation around tumor infiltration (Sfakianakis et al. 1982 b) Response to splenectomy (ratio of splenic to hepatic uptake) (Birnie et al. 1982) WBC kinetics (e.g., quantification of fecal WBC excretion) (Saverymuttu et al. 1983), others
pophilic compound that diffuses through the cell membrane and converts with time to a secondary complex that is less lipophilic. The conversion to a less lipophilic form inhibits back diffusion across the cell membrane (Segall et al. 1994). However, HMPAO is limited in that its rapid decomposition in vitro requires its usage within 30 min of preparation (Neirinckx 1987). In addition, elution of 99mTc is a major problem, 20% (Mortelmans et al. 1989) to 25% (Segall et al. 1994) of the label eluting from WBC by 24 h. The feasibility of using other chelating agents, such as the neutral lipophilic complex teboroxime, still needs further investigation. The labeling of WBC with 99mTc chelates, in particular HMPAO dramatically increased the widespread availability and use of these studies in nuclear medicine. Several clinical applications of radiolabeled WBC exist (Table 8.6), but the main clinical indication of imaging WBC distribution has been the detection of inflammatory bowel disease.
117
118
8.5 Conclusions
Peptides, proteins, and monoclonal antibodies or its fragments, with the potential for labeling specific subpopulations of WBC by binding to specific surface receptors or antigens of WBC, may be challenging and exciting in the future for selective cell labeling and in vivo studies.
8.5 Stem Cells Stem cell therapy is gaining considerable interest, mainly in cardiovascular medicine and oncology (Barbash et al. 2003, Bengel et al. 2005). Visualization and monitoring of the therapeutically administered cells could provide a better understanding of the underlying mechanisms and open a new field of research for clinical nuclear medicine. Preliminary attempts to label stem cells in vitro have been successful (Brenner et al. 2004, Chin et al. 2003). However, while labeling with In-111-oxine is above 80%, not affecting cell viability, a rather high elution rate was observed when labeling was performed with either 99mTc-HMPAO or 99mTc-oxine. Together with its shorter half-life, Tc-99m therefore does not allow longterm in vivo monitoring. Since the clinical use of labeled stem cells in patients is in a rather early stage, not enough information on the in vitro and in vivo viability is as yet available, in particular, the number of labeled cells required to correctly target the few percent of accumulating cells is not known. Other tracers, such as Cu-64 and 18F-labeled deoxyglucose (FDG) do not offer any advantage over In-111-oxine. Like with platelets, the labeling efficiency of stem cells is negatively affected by risk factors of cardiovascular disease (Sinzinger et al. 2006), such as cigarette smoking, diabetes mellitus, and hyperlipidemia.
8.6
Conclusions
Developments in both instrumentation and cell labeling have enabled a great expansion of their use in both clinical practice and research. Studies with 99mTc-RBC are in widespread use in clinical practice. In contrast, 99mTc has not been successfully applied to platelet labeling. In contrast to 99mTc-RBC-research, there have been more methodological reports with 99mTc-WBC than clinical applications at the present. Much progress has been achieved in the techniques of harvesting and labeling WBC, but many challenges remain. HMPAO is currently the best 99m Tc agent for labeling WBC, and played a particularly important role for the successful expansion of diagnostic imaging with radiolabeled WBC in nuclear medicine. New approaches, such as the use of peptides, proteins, antibodies, and molecular recognition unit technologies, may result in substantial improvements in the labeling methodology and could yield labeled cells with the least damage and high in vivo stability in the future.
Acknowledgments The authors gratefully acknowledge the collaboration and assistance by Judith Bednar, Susanne Granegger, Ulli Horvarth, Brigitte Jankovic, J. Kaliman, G. Karanikas, H.
Chapter 8 Cellular Labeling with
99m
Tc Chelates
Kolbe, H. Kritz, W. Linkesch, H. Ludwig, Ch. Mçller, Irmgard Neumann, J. O'Grady, Adelaide Osei-Bonsu, H. Pesl, Cornelia Pones, Sonja Reiter, Eva Strobl-Jåger, H. Vinazzer, K. Widhalm, and Ch. Zielinski.
References Angelberger P, Sinzinger H, Kolbe H, Leithner C (1981) Labelling of human platelets with 111Inoxine and 99mTc-oxine. Comparison of in vitro and clinical use for monitoring of kidney transplants. Progr Radiopharmacol 2:211±220 Arndt JW, van der Sluys Veer A, Blok K et al (1993) Prospective comparative study of technetium99m-WBCs and indium-111-granulocytes for the examination of patients with inflammatory bowel disease. J Nucl Med 34:1052±1057 Badenhorst PN, Lotter MG, Heyns A et al (1982) The influence of the ªcollection injuryº on the survival and distribution of indium-111-labelled canine platelets. Br J Haematol 52:233±240 Baldini MG, Myers TJ (1980) Utilit e limitazioni degli studi di sopravvivenza delle piastrine. Una valutazione critica [in Italian]. Haematologica 65:689±716 Barbash IM, Chouraqui P, Baron J, Feinberg MS, Etzion S, Tessone A, Miller L, Guetta E, Zipori D, Kedes LH, Kloner RA, Leor J (2003) Systemic delivery of bone marrow-derived mesenchymal stem cells to the infarcted myocardium: feasibility, cell migration, and body distribution. Circulation 108:863±868 Becker W, Borner W, Borst U (1988 a) 99mTc-hexamethylpropyleneamine-oxime (HMPAO) as a platelet label: evaluation of labelling parameters and first in vivo results. Nucl Med Commun 9:831±842 Becker W, Schomann E, Fischbach W et al (1988 b) Comparison of 99mTc-HM-PAO and 111In-oxine labelled granulocytes in man: first clinical results. Nucl Med Commun 9:435±437 Bengel FM, Schachinger V, Dimmeler S (2005) Cell-based therapies and imaging in cardiology. Eur J Nucl Med Mol Imaging 32:404±416 Berger CL, Ederson RL (1979) Comparison of lymphocyte function after isolation by Ficoll-Hypaque flotation or elutriation. J Invest Dermatol 73:231±235 Berger HJ, Zaret BL (1984) Radionuclide assessment of cardiovascular performance: radiopharmaceuticals. In: Freeman LM (ed) Freeman and Johnson's clinical radionuclide imaging. Grune & Stratton, Orlando, Fla., pp 366±367 Birnie, GG, Eadie AS, Hosie CJ et al (1982) 111In-labelled white blood cells in the diagnosis of Felty's syndrome. J Clin Pathol 35:74±76 Bowring CS (1986) Imaging and quantitative scanning. In: Radionuclides in hematology. Lewis SM, Baily RJ (eds) Churchill Livingstone, Edinburgh, pp 151±172 Brenner W, Aicher A, Eckey T, Massoudi S, Zuhayra M, Koehl U, Heeschen C, Kampen WU, Zeiher AM, Dimmeler S, Henze E (2004) In-111-labeled CD34+ hematopoietic progenitor cells in a rat myocardial infarction model. J Nucl Med 45:512±518 Bunting RW, Callahan RJ, Finkelstein S, Lees RS, William MS (1982) A modified method for labelling human platelets with indium-111 oxine using albumin density-gradient separation. Radiology 145:219±221 Chervu LR, Huq SS, Joseph JA et al (1981) Medication-induced changes in biodistribution of radiopharmaceuticals. J Nucl Med 22:72 Chin BB, Nakamoto Y, Bulte JW, Pittenger MF, Wahl R, Kraitchman DL (2003) In-111-oxine labelled mesenchymal stem cell SPECT after intravenous administration in myocardial infarction. Nucl Med Commun 24:1149±1154 Chisholm PM, Peters AM (1980) The effect of 111-indium labelling on the recirculation of rat lymphocytes. In: Thakur ML, Gottschalk A (eds) 111In-labelled neutrophils, platelets and lymphocytes. Trivirum, New York, pp 205±211 Chisholm PM, Danpure HJ, Healey G, Osman S (1979) Cell damage resulting from the labelling of rat lymphocytes and HeLa S3 cells with In-111-oxine. J Nucl Med 20:1308±1311 Danpure HJ, Osman S, Carroll MJ (1988) The development of a clinical protocol for the radiolabelling of mixed leukocytes with 99mTc-hexamethylpropyleneamine oxime. Nucl Med Commun 9:465±475 De Vries RA, De Bruin M, Marx JJM, Van De Wiel A (1993) Radioisotopic labels for blood cell survival studies: a review. Nucl Med Biol 20:809±817
119
120
References Eckleman W, Richards P, Hauser W, Atkins H (1979) Technetium-labelled red blood cells. J Nucl Med 20:22±24 Ferrant A, Lewis SM, Szur L (1974) The elution of 99mTc from red cells and its effect on red cell volume measurement. J Clin Pathol 27:983±985 Fisher DG, Koren HS (1981) Isolation of human monocytes. Adams DO, Edelson PJ, Koren HS (eds) In: Methods for studying mononuclear phagocytes. Academic, New York, 43±47 Gorman, RR, Bunting S, Miller OV (1977) Modulation of human platelet adenylate cyclase by prostacyclin (PGX). Prostaglandins 13:377±388. Granegger S, Flores J, Widhalm K, Sinzinger H (1988) Increased low-density lipoproteins (LDL) negatively affect human labelling. Folia Haematol 115:451±453 Harker LA, Slichter SJ, Sauvage LR (1977) Platelet consumption by arterial prostheses: the effects of endothelialization and pharmacologic inhibition of platelet function. Ann Surg 186:594±601 Hawker RJ, Hawker LM, Wilkinson AR (1987) Indium-labelled human platelets. Optimal method. Clin Sci 58:243±248 Hegge FN, Hamilton GW, Larson SM et al (1978) Cardiac chamber imaging: a comparison of red blood cells labelled with Tc-99m in vitro and in vivo. J Nucl Med 19:129 Hladik WB, Nigg KK, Rhodes BA (1982) Drug-induced changes in the biologic distribution of radiopharmaceuticals. Semin Nucl Med 12:184 International Committee For Standardization In Hematology (1988) Panel on diagnostic applications of radionuclides. Recommended method for indium-111 platelet survival studies. J Nucl Med 29:564±566 Kao CH, Hunang WT, Wang YL et al (1994) A comparative study of 99mTc-HM-PAO and 99mTcECD as a leukocyte labelling agent. Nucl Med Comm 15:294±297 Lantto EH, Lantto TJ, Vorne M (1991) Fast diagnosis of abdominal infections and inflammations with technetium-99m-HM-PAO labeled leukocytes. J. Nucl Med 32:2029±2034 Lee HB, Wexler JP, Scharf SC et al (1983) Pharmacologic alterations in Tc-99m binding by red blood cells: concise communication. J Nucl Med 24:397±401 Leitl GP, Drew HM, Kelly ME et al (1980) Interference with Tc99m-labelling of red blood cells (RBCs) by RBC antibodies. J Nucl Med 21:44 Lætter MG, Heyns AD, Badenhorst PN et al (1987) Evaluation of mathematic models to assess platelet kinetics. J Nucl Med 27:1192±1201 Mathias CJ, Welch MJ (1979) Labelling mechanism and localization of indium-111 in human platelets. J Nucl Med 20:659 Mathias CJ, Welch MJ (1984) Radiolabelling of platelets. Semin Nucl Med 14:118±127 McAfee JG, Subramanian G, Gagne G (1984) Technique of leukocyte harvesting and labeling: problems and perspectives. Semin Nucl Med 14:83±106 Mollison PL, Engelfriet CP, Contreras M (1987) The transfusion of platelets, leukocytes, haemopoietic cells and plasma components. In: Blood transfusions in clinical medicine. Blackwell, Oxford, pp 7±27 Mortelmans L, Verbruggen A, De Roo M, Vermylen J (1986) Evaluation of three methods of platelet labeling. Nucl Med Comm 7: 519±529 Mortelmans L, Malbrain S, Stuyck J et al (1989) In vitro and in vivo evaluation of granulocyte labeling with (99mTc)d,l-HM-PAO. J Nucl Med 30:2022±2028 Mountford PJ, Kettle AG, O`Doherty MH, Coakley AJ (1990) Comparison of technetium-99m-HMPAO leukocytes with indium-111-oxine leukocytes for localizing intraabdominal sepsis. J Nucl Med 31:311±315 Najean Y (1986) The choice of tracer for platelet kinetics and scintigraphic studies. Nucl Med Biol 13:159±164 Neirinckx R, Canning L, Piper I et al (1987) Technetium-99m-d,l-HM-PAO: a new radiopharmaceutical for SPECT imaging of regional cerebral blood perfusion. J Nucl Med 28:191±202 Peters AM (1988) Review of platelet labelling and kinetics. Nucl Med Commun 9:803±808 Peters AM, Saverymuttu SH, Danpure HJ, Osman S (1986) Cell labeling. In: Bailey RJ, Lewis SM (eds) Radionuclides in haematology. Churchill Livingstone, Edinburgh, pp 79±109 Porter WC, Dees SM, Freitas JE, Dworkin HJ (1983) Acid-citrate-dextrose compared with heparin in the preparation of in vivo/in vitro technetium-99m red blood cells. J Nucl Med 24:383±387 Rao SA, Knobel J, Collier D et al (1986) Effect of Sn (II) ion concentration and heparin on technetium-99m red blood cell labelling. J Nucl Med 27:1202±1206. Raptopoulos V, Doherty PW, Goss TP et al (1982) Acute osteomyelitis: advantage of white cell scans in early detection. Am J Roentgenol 139:1077±1082
Chapter 8 Cellular Labeling with
99m
Tc Chelates
Reiter S, Angelberger P, Kolbe H, Sinzinger H (1984) In vitro- und In vivo-Untersuchungen mit 111 Indium-Oxin, 111Indium-Oxin-Sulfat und 99mTc-Oxin zur Erythrozytenmarkierung [in German]. Wien Klin Wschr 3:120±123 Riordon F, Nelp WB (1982) Binding capacity of normal and sickle cell hemoglobin for technetium atoms. J Nucl Med 23:91 Roddie ME, Peters AM, Danpure HJ et al (1988) Inflammation: imaging with Tc-99m HM-PAO-labelled leukocytes. Radiology 166:767±772 Rodrigues M, Sinzinger H (1994) Platelet labeling ± methodology and clinical applications. Thromb Res 76:399±432 Sampson CB (1993) Adverse reactions and drug interactions with radiopharmaceuticals. Drug Saf 8:280±294 Sampson CB (1995) Influence of drugs on cell labelling. 6th European Symposium on Radiopharmacy and Radiopharmaceuticals. Graz, March 1995 Saverymuttu SH, Peters AM, Lavender JP et al (1983) Quantitative fecal indium-111 labelled leukocyte excretion in the assessment of activity in Crohn's disease. Gastroenterology 85:1333. Scheffel U, Tsan MF, McIntyre M (1979) Labeling of human platelets with (111In)8-hydroxyquinoline. J Nucl Med 20:524±531 Schneider W, Gear ARL (1994) Significance of glucose and glycogen metabolism for platelet function. Am J Physiol 3:225±232 Segall GM, Lang HV, Chaovapong W (1994) In vitro evaluation of white blood cell labelling with 99m Tc radiopharmaceuticals. Nucl Med Commun 15:845±849 Sfakianakis GN, Al-Sheikh W, Heal A et al (1982) Comparison of scintigraphy with In-111 leukocytes and Ga-67 in the diagnosis of occult sepsis. J Nucl Med 23:618 Sfakianakis GN, Mnaymneh W, Ghandus-Mnaymneh L et al (1982) Positive In-111 leukocyte scintigraphy in a skeletal metastasis. Am J Roentgenol 139: 601±603 Sinzinger H, Granegger S (1988) The effect of various antibiotics on the labelling efficiency of human white blood cells with 111In-oxine. Nucl Med Comm 9:597±601 Sinzinger H, Angelberger P, Hæfer R (1981) Platelet labelling with 111In-oxine: benefit of prostacyclin (PGI2) ± addition for preparation and injection. J Nucl Med 22:292 Sinzinger H, Flores J, Widhalm K, Granegger S (1987 a) Platelet viability (aggregation, migration, recovery) after radiolabelling of platelets from hypercholesterolemics using various tracers (oxine, oxine-sulphate, tropolone, MPO). Eur J Nucl Med 14:358±361 Sinzinger H, Fitscha P, Kaliman J (1987 b) Prostaglandin I2 improves recovery, but does not change platelet half-life and platelet uptake over active human lesion sites. Prostaglandins 33:787±790 Sinzinger H, Granegger S (2006) Radionuclide vascular imaging and characterization of human metabolic endothelial surface lining. Q J Nucl Med Mol Imaging 50:226±235 Sinzinger H, Kolbe H, Strobl-Jåger E, Hæfer R (1984) A simple and safe technique for sterile autologous platelet labelling using ªMonovetteº vials. Eur J Nucl Med 9:320±322 Skretting A, Benestad HB, Sundrehagen H (1988) Whole body distribution of 99mTc labelled autologous human granulocytes and radiation dose to cells and organs. Eur J Nucl Med 14:1±7 Srivastava S, Rao Chervu L (1984) Radionuclide-labelled red blood cells: current status and future prospects. Semin Nucl Med 14:68±82 Srivastava S, Straub RF (1990) Blood cell labelling with 99mTc: progress and perspectives. Semin Nucl Med 20:41±51 Sweeney JD, Holme S, Heaton WAL, Nelson E (1995) White cell-reduced platelet concentrates prepared by in-line filtration of platelet-rich plasma. Transfusion 35:131±136 Tatum JL, Burke TS, Hirsh JI et al (1983) Pitfall to modified in vivo method of technetium-99m red blood cell labelling. Iodinated contrast media. Clin Nucl Med 8:585±587 Thakur ML, Welch MJ, Malech HL (1981) Indium-111 labelled human platelets: improved method, efficacy and evaluation. J Nucl Med 22:381±385 Thierens HM, Vral AM, Van-Haelst JP et al (1982) Lymphocyte labelling with technetium-99mHM-PAO: a radiotoxicity study using the micronucleus assay. J Nucl Med 33:1167±1174 Towler HMA (1984) Effect of 111In-oxinate and tropolonate labelling on human platelet aggregation and b-thromboglobulin release. In: Thakur ML, Ezekowitz MD, Hardeman MR (eds) Radiolabeled blood cellular elements. Plenum, New York Uchida T, Nemoto T, Yui T et al (1979) Use of technetium-99m as a radioactive label to study migratory patterns of leukocytes. J Nucl Med 20:1197±2000 Vallabhajosula S, Machac J, Goldsmith SJ et al (1986) 111Indium platelet kinetics in normal human subjects: tropolone versus oxine methods. J Nucl Med 27:1669±1674
121
122
References Wagner X, Granegger S, Dembinska-Kiec A, Sinzinger H (1998) Nitric oxide (NO) for radiolabelling of human platelets. In: Sinzinger H, Thakur ML (eds) Nuclear medicine research. Facultas, Vienna, p 58 Webber D, Nunan TO, Doherty JO (1994) The effect of varying type and volume of sedimenting agents on leukocyte harvesting and labelling in sickle cell patients. Nucl Med Comm 15:735± 741 Wilson ME, Hung JC (1992) Evaluation of heparin and anticoagulant citrate dextrose in the preparation of technetium-99m-red blood cells with Ultra Tag¾ RBC kit. J Nucl Med 33:306±307 Winzelberg GG, McKusick KA, Froelich JW et al (1982) Detection of gastrointestinal bleeding with 99m Tc-labelled red blood cells. Semin Nucl Med 12:139±146
Chapter 9
Quality Control Methods of 99mTc Pharmaceuticals
9
9.1 Determination of Radiochemical Purity 9.1.1 Thin-Layer Chromatography Methods C. Decristoforo and I. Zolle Thin-layer chromatography (TLC) is commonly used for the determination of radiochemical purity in nuclear medicine. TLC was described as early as 1967 for testing radiopharmaceuticals (Hoye 1967). Since the introduction of TLC (Izmailov and Shraiber 1938; Stahl 1956), a variety of modifications and new applications have been reported (Fairbrother 1984). The principle of this analytical method is that a mobile phase (solvent) moves along a layer of adsorbent (stationary phase) due to capillary forces. Depending on the distribution of components between the stationary and the mobile phase, a radioactive sample spotted onto the adsorbent will migrate with different velocities, and thus, impurities are separated. The distance each component of a sample migrates is expressed as the Rf value. The Rf is the relative migration of a component in relation to the solvent front (SF): Rf
Distance from origin of the component Distance of the SF
The Rf values range from 0±1. If a component migrates with the SF, the Rf is 1. If a component remains at the point of application (origin), the Rf is 0. For a given TLC system, which is defined by the mobile and the stationary phases, the Rf value of a pure chemical compound is specific and reproducible. The main principles of separation are adsorption (electrostatic forces), partition (solubility), and ion exchange (charge). Information on the theoretical background of TLC is presented elsewhere (Miller 2004). Depending on the movement of the mobile phase, TLC may be ascending or descending; in the nuclear medicine laboratory, ascending TLC is the method of choice (Robbins 1983). For the analysis of radiopharmaceuticals, techniques should be fast and safe. TLC offers reliable separation properties with easy and rapid performance. The applied sample remains quantitatively on the plate, and therefore, no losses of radioactivity during analysis occur. The commercially available ready-to-use stationary phases combine adsorbent with ionic or hydrophobic properties and are suited for separation of a variety of molecules using polar or nonpolar solvents. This chapter emphasizes methods for routine use in nuclear medicine and describes materials, techniques, and methods for quantification (Carpenter 1986; Hammermaier et al. 1986; Thoebald 1984).
124
9.1 Determination of Radiochemical Purity
9.1.1.1
99m
Tc Species Separated by TLC
The main impurities in 99mTc pharmaceutical preparations are free pertechnetate (99mTcO±4) and reduced, hydrolized technetium (colloidal 99mTc). These two 99mTc species may be separated from 99mTc pharmaceuticals by simple TLC procedures. The migration properties of free pertechnetate may be influenced by the choice of different mobile and stationary phases. When silica gel or paper is used as stationary phase, the migration of free pertechnetate depends on the solubility of this anion in the solvent. In a polar solvent like saline, 80% methanol, acetone or 2-butanone (methyl ethyl ketone, or MEK) pertechnetate migrates with the SF (Rf = 0.6±1.0). If a nonpolar, lipophilic solvent (e.g., ethylacetate, chloroform) is used and the sample is dried (no water content), free pertechnetate remains at the origin. In addition, when using an anion-exchange material in for stationary phase (e.g., aluminum oxide), free pertechnetate will be retained at the start. Colloids do not migrate in most TLC systems since insoluble material will stay at the origin. Changing the mobile or the stationary phase will not affect the migration properties of colloidal 99mTc. This is the reason why hydrolized 99mTc species are not determined in colloidal and particulate preparations (e.g., macroaggregated albumin [MAA]), microspheres, or high-molecular 99mTc species such as monoclonal antibodies. The major impurity recognized by the pharmacopeia in the case of these radiopharmaceuticals is free pertechnetate, moving with the SF (Robbins 1983; Zimmer and Pavel 1977).
9.1.1.2 Stationary Phases Standard TLC Materials. Standard TLC plates are available as glass plates, and as plastic or aluminum foils covered with the stationary phase. Aluminum or plastic foils have the advantage that they are easily cut into pieces for measurements of radioactivity. A broad range of stationary phases is commercially available including silica gel, reversed-phase silica, aluminum oxide, synthetic resins (ion-exchange chromatography), and cellulose (partition chromatography). The length of plates (foils) may vary between 10 and 20 cm, although miniaturized systems have been introduced (< 5 cm). Generally, the developing distance will depend on the number of components in a sample and the relative retention properties in a system as well as the time used for migration. For determination of the radiochemical purity of 99mTc pharmaceuticals, methods using standard TLC materials have been described (Zimmer and Pavel 1977). Reversedphase materials offer advantages with respect to more polar solvents that are miscible with the aqueous medium of the sample (Carpenter 1986). Alumina plates are used to separate anionic 99mTc-pertechnetate from neutral or positively charged complexes. The main limitation of standard TLC techniques is the time required for analysis. Due to the particle size (20 lm) of adsorbent materials, the developing time is usually > 30 min. This is too long considering additional time for measurements and quantification. The main advantage of standard TLC materials lies in the comparably high resolution, exemplified by the separation of two 99mTc-dimercaptosuccinic acid (DMSA) complexes in one TLC system: The trivalent 99mTc-DMSA complex is separated as an impurity in a preparation of pentavalent 99mTc-DMSA (Westera et al. 1985).
Chapter 9 Quality Control Methods of
99m
Tc Pharmaceuticals
High-Performance TLC (HPTLC). HPTLC materials have a smaller average particle size (5 vs 20 lm) and a narrower particle size distribution when compared with conventional materials. Actually, the development of the chromatogram is faster and the time for analysis shorter. However, HPTLC materials are preferable for more complex separations; their use for determinations of the radiochemical purity in nuclear medicine is limited. Instant TLC (ITLC). ITLC materials are the most frequently used stationary phases in nuclear medicine. ITLC methods fulfill the need for rapid and accurate analysis of the radiochemical purity of radiopharmaceuticals and have thus been accepted by the European Pharmacopeia. ITLC plates are made of fiberglass sheets, impregnated with an adsorbent, usually silica gel (e.g., SG). Due to the fine mesh material, the migration properties are increased many-fold by the TLC materials. The time for the development of any chromatogram may be reduced to < 5 min, without affecting the separation of radiochemical impurities. Although ITLC materials are more expensive, fiberglass sheets offer high economy, since the flexible material may be cut to any size. Chromatographic systems utilizing these materials have been described (Frier and Hesslewood 1980; Theobald 1994; Zimmer and Pavel 1977). The separation properties of silica gel 60 depend to a certain extent on the ªactivatedº state of the adsorbent, which is related to the water content. However, when using organic solvents, it is recommended to dry the ITLC plate before use by heating for 10±20 min at 110 8C (Frier M and Hesslewood 1980). The most common impurities in radiopharmaceuticals remain at the origin (Rf = 0) or migrate with the SF (Rf = 0.8±1.0). In order to separate and quantify two (or more) impurities, two (or more) analytical systems are generally used. A typical procedure, using different solvents, is shown in Fig. 9.1.1.1. Using an organic solvent (MEK) for separation, colloidal forms and the Tc complex remain at the origin, and free pertechnetate migrates with the SF. This system is suited to quantify free 99mTc-pertechnetate. In saline, free pertechnetate and the 99mTc complex migrate with the SF; while reduced, hydrolyzed 99mTc remains at the start. Using saline, the colloidal 99mTc species is quantified. With some experience, the whole procedure may be performed in < 15 min, before application of the radiopharmaceutical to patients. Attention must be paid when ITLC strips are marked to indicate the spotting area or SF, since the material is fragile and easily damaged, which may affect results. Silica Gel. The chemical properties are based on siloxane (Si±O±Si) and silanol (Si± OH). Polar groups are responsible for the interaction of the adsorbent with water and with the sample to be analyzed. Silica stationary phases (3±8 lm) have been produced for ITLC as silica gel (ITLC-SG) and silicic acid (ITLC-SA). ITLC-SG is the most frequently used adsorbent for routine radiochemical purity determinations (Table 9.1.1.1). RP Phases. The surface properties of silanol may be modified by reaction with alkylating agents that bind to the surface of porous silica gel 60. Hydrophobic modification includes binding of nonpolar groups such as dimethyl (RP-2), octyl (RP-8), octadecyl (RP-18), and phenyl. The hydrophobic properties increase within the different groups from RP-2 to RP-18, and with the degree of saturation of the hydroxyl groups that has been attained.
125
Fig. 9.1.1.1. Determination of the radiochemical purity of a radiopharmaceutical by instant thin-layer chromatography (ITLC) using two different solvents, methyl ethyl ketone (MEK) and saline
126 9.1 Determination of Radiochemical Purity
Chapter 9 Quality Control Methods of
99m
Tc Pharmaceuticals
Table 9.1.1.1. Materials for thin-layer chromatography (TLC) Layer type
Format (cm)
Ordering no.
Quantity
TLC glass plates (layer thickness 0.2 and 0.25 mm) 20 ´ 20 Silica gel 60 F254 5 ´ 10 Silica gel 60 F254 2.5 ´ 7.5 Silica gel 60 F254 20 ´ 20 RP-18 F254 5 ´ 20 RP-18 F254 5 ´ 10 RP-18 F254 5´5 HPTLC Si 60 F254 20 ´ 10 HPTLC LiChrospher Si 60 F254
Merck Merck Merck Merck Merck Merck Merck Merck
1.05715.000 1.05789.000 1.15327.000 1.15389.000 1.15683.000 1.15685.000 1.05635.000 1.15445.000
25 25 100 25 50 25 100 25
plates plates plates plates plates plates plates plates
TLC aluminum sheets (layer thickness 0.2 mm) Silica gel 60 20 ´ 20 5 ´ 10 Silica gel 60 F254 5 ´ 7.5 Silica gel 60 F254 20 ´ 20 Aluminum oxide 60 F254 neutral 20 ´ 20 Aluminum oxide 150 F254 neutral 20 ´ 20 HPTLC LiChrospher Si 60 F254
Merck Merck Merck Merck Merck Merck
1.05553.0001 1.16834.0001 1.05549.0001 1.05550.0001 1.05551.0001 1.05586.0001
25 50 20 25 25 25
sheets sheets sheets sheets sheets sheets
TLC plastic sheets (layer thickness 0.2 mm) 20 ´ 20 Silica gel 60 F254 20 ´ 20 Aluminum oxide 60 F254 Baker-flex silica gel 1B-F 20 ´ 20 Baker-flex silica gel 1B-F 2.5 ´ 7.5 Baker-flex aluminum oxide 1B-F 20 ´ 20 Baker-flex aluminum oxide 1B-F 2.5 ´ 7.5
Merck 1.05735.0001 Merck 1.05581.0001 J. T. Baker 4463-04 J. T. Baker 4463-02 J. T. Baker 4467-04 J. T. Baker 4467-02
25 25 25 200 25 200
sheets sheets sheets sheets sheets sheets
ITLC fiberglass sheets (layer thickness 0.2 mm) Silica gel (ITLC-SG) 20 ´ 20 Silica gel (ITLC-SG) 5 ´ 20 Silicic acid gel (ITLC-SA) 20 ´ 20
Pall Gelman 61886 Pall Gelman 61885 Pall Gelman 51432
25 sheets 50 sheets 25 sheets
HPTLC high-performance thin-layer chromatography, ITLC instant thin-layer chromatography
RP phases offer higher selectivity for separation of nonpolar compounds or molecules with nonpolar groups. In certain cases, highly polar, ionic compounds may also be separated due to selective retention on these modified RP materials. Partially modified silica gel is also available as RP-18 alumina sheets. Silica gel may also be modified with hydrophilic groups that are attached using short-chain nonpolar spacers. Hydrophilic modifications with polar groups include amino, cyano, and diol functionalities. Amino-SG offers weakly basic ion-exchange properties; diol-SG considerably less affinity for water when compared with unmodified SG-60. These HPTLC materials offer increased selectivity for complex separations of biomolecules and drugs. Aluminum Oxide. Some separations of radiopharmaceuticals are based on adsorption chromatography with aluminum-coated plates. Aluminum oxide (Al2O3) has polar properties; it is also a weak anion exchange material. The pH adjusted adsorbent is available in three pH ranges: neutral (pH 7.0±8.0), basic (pH 9.0±10.0), and acidic (pH 4.0±4.5). Standardized products include aluminum oxide 60, 90, and 150. Plates are also available for UV detection.
127
128
9.1 Determination of Radiochemical Purity Table 9.1.1.2. Materials for paper chromatography Specification
Format (mm)
Ordering no.
Quantity
Whatman Whatman Whatman Whatman Whatman Whatman Whatman
100 ´ 300 200 ´ 200 50 ´ 250 100 ´ 130 150 ´ 150 200 ´ 200 460 ´ 570
3001845 3001861 30306122 30306123 3030286 3030861 3031915
100 100 50 50 100 100 25
1 1 3MM 3MM 3MM 3MM 31 ET
sheets sheets sheets sheets sheets sheets sheets
Cellulose. This organic material consists of polymerized glucose fibers (400±500 molecules) in nature and also as a synthetic product (40±200 glucose molecules). Cellulose interacts with water and serves as a stationary phase for the separation of polar substances by paper chromatography. As a powder, it is used as an adsorbent for TLC. Separation of polar substances by paper chromatography is described in the European Pharmacopeia for identification of 99mTc-pertechnetate (Council of Europe 1982). Paper. Paper was the first material used for chromatography of radioactive compounds (Dickey 1953). Paper materials show low-resolution properties; however, since paper is robust and easy to cut, paper chromatography is still used and recommended for many applications. The mechanism of separation is probably different; nevertheless, paper chromatography is used ªascendingº or ªdescendingº, like ITLC. Likewise, a developing distance of 8±10 cm is usually sufficient for the separation of free pertechnetate and colloidal impurities. The developing time might be slightly increased, but usually finished in < 10 min, if small sized paper strips are used. Whatman 3MM is the material of choice for determination of the radiochemical purity by partition chromatography. (For information on materials, Tables 9.1.1.1 and 9.1.1.2.)
9.1.1.3 Mobile Phases The saline/MEK system is applied for the analysis of most radiopharmaceuticals that contain free pertechnetate and/or colloidal Tc. Acetone has been replaced by MEK because artificially high values of pertechnetate have been obtained, caused by its higher water content (Carpenter 1986). More recently, developed 99mTc complexes (e.g. mercaptoacetyltriglycine [MAG3], monodentate methoxyisobutyl isocyanide [MIBI], hexamethylpropylene amine oxime [HMPAO], etc.) require more sophisticated analytical methods to detect additional impurities in the injection solution. This is inherent in the chemical properties of certain 99m Tc pharmaceuticals that need more complex kit formulations and contain several labeled impurities. In addition, special composed solvent systems have to be used.
Chapter 9 Quality Control Methods of
99m
Tc Pharmaceuticals
9.1.1.4 Spotting of the Sample The sample size has a considerable effect on the separation characteristics of a certain system. Therefore, the sample diameter on the plate should be kept as small as possible (< 3 mm). Inefficient separations and artificial results are caused by too-large spots. The standard TLC technique for applying a sample onto the plate is to use micropipets or glass capillaries for single use. The volume is typically 5 ll. A certain drawback of this technique is the fact that the sample is withdrawn aseptically with a syringe from the vial and needs to be transferred for spotting. Therefore, to reduce handling, the sample is withdrawn using a 1-ml syringe with a fine needle (> 25 gauge) and is spotted directly onto the plate using a single drop from the needle. The volume corresponding to a drop from a vertically held needle (25 gauge) is approximately 6 ll. If the syringe is held in the horizontal position, the volume might double (Robbins 1983). With experience, reproducibly small spots are applied to the TLC plate, suitable for analysis. The technique also avoids contamination and minimizes sample exposure to air, which may affect certain 99mTc radiopharmaceuticals.
9.1.1.5 Development of the Chromatogram For the development of chromatograms, a small beaker might be used, which is closed with a glass plate or covered with a foil to maintain a saturated atmosphere inside the vessel. Small tanks for chromatography are recommended, especially when organic solvents are used. If an open beaker is used, evaporation of the solvent may affect the separation properties of a system (Levit 1980; Manger 1986). The solvent should cover the bottom not more than 5 mm high; the solvent level has to be below the start line on the plate/strip. After applying the sample, the plate must be placed into the tank and developed immediately, without drying the spot. Dried samples may lead to artificial results due to oxidation of 99mTc complexes and formation of free pertechnetate (Mallol 1990; Manger 1986). An exception to this rule is made for mobile phases that do not dissolve the aqueous sample (e.g., ethylacetate, chloroform). In this case, a wet sample will produce a poor resolution and high background activity along the track. The sample spot should be dried in a gentle stream of nitrogen, and heating the plate must be avoided. The plate/sheet is placed vertically into the chamber, carefully avoiding any damage of the surface. Materials with limited mechanical resistance like certain chromatography paper should be supported (e.g., clipped to the lid of the chamber), otherwise they will slip into the solution or touch the chamber wall during development. The usual developing time is between 2 and 15 min, depending on the stationary phase and (to a lesser extent) on the solvent. The SF is not always visible, especially when using ITLC materials. Therefore, SF (end of chromatogram) is marked with a color pen (water soluble for aqueous solutions; water resistant for organic solvents) (Fig. 9.1.1.2). When the solvent gets in contact with the marker, the color migrates with the solvent, indicating the end of the development. The strip should be marked in such a way that the color does not interfere with the sample track to avoid artificial results (Levitt 1980). When the solvent has reached SF, the strip is removed from the chamber and then dried.
129
130
9.1 Determination of Radiochemical Purity
Fig. 9.1.1.2. ITLC plates before and after development (typical dimensions). The application point is marked with a line; a color pen marker may be used to mark the solvent front. When the solvent reaches the marker, the color migrates with the solvent. Markers are positioned outside the track to avoid interference with the sample
Procedure for the determination of radiochemical purity by ITLC or paper chromatography: · Fill a 100-ml beaker with the solvent (about 10 ml, solvent 3±5 mm high); close the beaker with a tight lid or parafilm. · Prepare the strip: Mark the solvent front with a color pen and the start with a pencil. · Take a small sample of the preparation ready for injection (< 100 ll). · Apply one small drop of the sample with a thin needle onto the strip; the drop must not dry. · Immediately put the strip into the beaker, the spot must remain above the solvent level. · When the solvent has reached the front, take the strip out and let it dry. · Quantify the regional distribution of radioactivity on the strip.
9.1.1.6 Measurement of Radioactivity There are several methods for the quantification of radiochromatograms. Depending on the available instrumentation, the resolution of analysis will vary, and the amount of radioactivity used for analysis will differ considerably. In any case, the results of measurements are used to calculate the radiochemical purity of a radiopharmaceutical (percentage) as the ratio between the radioactivity corresponding to the main component, divided by the total recovered radioactivity of the chromatogram:
Chapter 9 Quality Control Methods of
Radiochemical purity
%
99m
Tc Pharmaceuticals
Radiopharmaceutical
dpm 100 Total recovered activity
dpm
The relative merits of quantification methods are: · Resolution · Sensitivity · Linearity · Time needed to perform · Practicability · Costs Autoradiography. Autoradiography is one of the oldest methods used for semiquantitative measurement of radioactivity. The chromatogram is placed on an x-ray film and exposed in the dark for usually less than 1 h (a detailed procedure is given elsewhere) (Theobald 1994). This method is no longer in use since it is time-consuming and inaccurate. Visualization of the radioactivity distribution on a film may be useful for documentation purposes. Gamma Camera. Measurement of a radiochromatogram with a gamma scintillation camera might be first choice when no specific instrumentation is available. The dried strip is placed at close distance to the head of the gamma camera, and images are acquired. Using the regions of interest (ROI) technique (drawing regions over distinct areas of activity), the radiochemical purity is expressed as a fraction of the total recovered activity. A certain advantage is the use of undiluted sample for chromatography (measurement of high count rates). The main disadvantage of this technique is that it is a rather time-consuming procedure (measurement and analysis) at a time when the camera is needed for patients. In cases when no other device is available, visualization of the radioactivity distribution by an activity profile might be a good indicator of the amount of impurities present in the injection solution. Ionization Chamber. This method is frequently used and is recommended in many official procedures (Robbins 1983). It might be used for simple separation techniques (compounds with an Rf of 0 or 1). The strip is cut into two segments (one corresponding to the main compound and the other to the impurity) and measured in the ionization chamber. This facilitates quick analysis before the radiopharmaceutical is injected. Limitations are low resolution of measurements, an overestimation of the amount of impurities, and if not cut properly, results may be wrong. This problem can be avoided by cutting the strip into more segments, which are measured separately (Bish et al. 1980). Second, the sensitivity is limited by the sensitivity of the ionization chamber. In practicee, 3 MBq or more should be applied on the plate, which would correspond to an injection solution of 600 MBq/ml if 5 ll are applied (Robbins 1983). Results with lower concentrations of radioactivity should be judged with caution. Cut and Count. Chromatographic plates may be analyzed using a NaI(Tl) scintillation counter. The plates are cut in segments (up to ten) and transferred into tubes to be counted. The radioactivity on the plate can be plotted as a histogram. The sensitivity is much higher compared with the ionization chamber (even dilution may be necessary), and the resolution is dependent on the number of segments. It is important to keep the
131
132
9.1 Determination of Radiochemical Purity
same counting geometry for all segments at the bottom of the counting tube. Cutting the plate in many segments permits assessment of the quality of separation. The background radioactivity is subtracted from each count leading to a more accurate analysis. The main limitations of this method are that the high activities of the main component may paralyze the counter (Robbins 1983), and the procedure is time-consuming (cutting samples and filling into test tubes, time of measurements, and calculation of the relative percentages). Chromatogram Scanning. The advantage of this method is the fact that a slit-collimated detector is moved along the thin-layer plate, and the radioactivity distributed between the start and SF of a chromatogram is recorded. The detector is coupled to a scaler ratemeter, with the ratemeter output signal passed on to a chart recorder producing a radioactivity profile (Janshold et al. 1980). A useful addition is a chromatography integrator to measure the area of radioactive peaks, which is proportional to the detected radioactivity. Quantification of single peaks as a percentage of the total measured radioactivity will produce a purity report for each radiopharmaceutical. For measuring 99mTc and other gamma emitters, a NaI(Tl) scintillation detector is used. The resolution of the scanner is dependent on the width of the slit-collimator, the distance between chromatogram and detector, and the window settings on the scaler. Artificial results may be obtained if the peaks are not symmetrical and comparable. Linear Analyzer. The linear analyzer was developed for the measurement of beta-emitting radionuclides and was introduced in 1980 by Berthold Analytical Instruments (Filthuth 1986). It operates as a position-sensing proportional counter, measuring a fixed number of channels along the length of the chromatographic plate. The system is equipped with analytical software for quantification. Further developments have increased the potential of proportional counting by placing a grid of anode wires between two large plates, 1.5 mm above and below, serving as cathodes. Ions formed in the gas-filled volume drift toward the nearest anode wire where they undergo multiplication; each event is automatically localized. Thus, two-dimensional localization may be accomplished by these position-sensing detectors. The digital autoradiograph is a multiwire proportional counter; each electrode is composed of 100 wires (gold-plated tungsten) arranged at a 2-mm distance. The gasfilled proportional chamber has a window of 24 ´ 24 cm for the measurement of chromatograms at a fixed distance (0.5 mm). Each channel is connected with a time analyzer for registration of position specific pulses (nanoseconds). Finally, the analog signals are digitalized for computer analysis and quantification. Gas flow proportional counters exhibit higher sensitivity for beta-emitters, but also pure gamma-emitters like 99mTc are measured with high resolution. When placing a chromatogram into the counting chamber the developed strip must be completely dry. The main advantages over a conventional TLC scanner are: · Increased sensitivity because of the high specific ionization produced in the gasfilled proportional chamber using argon/methane (89 : 10) · Two-dimensional positioning of radioactivity · A ªphotographicº image of the radioactivity distribution is generated · Several chromatograms (strips) are analyzed during one exposure · The linear analyzer and the digital autoradiograph may be used with any radionuclide · Quantification of chromatograms, storage, and display of data · Resolution may decrease with high activities.
Chapter 9 Quality Control Methods of
99m
Tc Pharmaceuticals
Fig. 9.1.1.3. ªPhantomº chromatographic plate analyzed by four different methods of measurement. The highest sensitivity is achieved with A and C, the best resolution with B and C. Using the ionization chamber (D), activities less than 20 kBq (peak 1, 2, 3, 4) are not resolved accurately.
A comparison of four different methods of quantification is shown in Fig. 9.1.1.3. A ªphantomº chromatographic plate with increasing amounts of radioactivity (0.25, 1.0, 4.0, 16.0, and 64.0 kBq) spotted at exact intervals was measured by: A. linear analyzer, B. conventional scanner, C. cut/measure, and D. ionization chamber (Capintec). The highest sensitivity was achieved with A. and C., the best resolution with B. and C. Using the ionization chamber indicated low detection efficiency of radioactivity below 20 kBq (peaks 1, 2, 3, and 4). Linear analyzers and conventional TLC scanners are standard equipment in nuclear medicine. These instruments offer high detection efficiency and resolution characteristics combined with speed of analysis, which is required for the analysis of short-lived radiopharmaceuticals. Electronic Autoradiography. New methods have been developed with the aim of replacing the time-consuming film autoradiography. Two different systems, the so-called phosphor imagers and the microchannel plate analyzers, are currently available for quantifying TLC plates, ITLC, or paper strips. While phosphor imagers require two steps for quantification of an autoradiogram (exposure and ªdevelopmentº), microchannel plate analyzers provide a direct measurement of radioactivity. The main advantages are a short analysis time, high sensitivity, a broad dynamic range, system stability at high radioactive concentrations, online two-dimensional imaging, direct quantification of radioactivity, and detectability of all radionuclides used in nuclear medicine. A de-
133
134
9.1 Determination of Radiochemical Purity
Fig. 9.1.1.4. Electronic autoradiogram of two ITLC-SG strips showing the radiochemical purity of 99m Tc-diethylene triamine pentaacetate (DTPA) in two solvent systems: A MEK: 99mTc-DTPA remains at the start, B MeOH (80%): 99mTc-DTPA moves with SF. Strip dimensions: 1.5 ´ 10 cm. (Instant Imager, Canberra Packard, acquisition time: 60 s)
tailed description of such a system (Instant Imager, Canberra Packard) for radiopharmaceutical applications is described in (Decristoforo 1977). Figure 9.1.1.4 shows an electronic autoradiogram of the radiochemical purity of 99mTc-diethylene triamine pentaacetate (DTPA). These instruments offer a wide range of radioanalytical applications besides radiochemical purity determinations, yet the high cost may limit their use in nuclear medicine.
9.1.1.7 Summary The determination of the radiochemical purity in nuclear medicine may be performed with little expenditure of material. Minimal equipment for routine determination of the radiochemical purity with TLC: · Two chromatographic chambers for small volumes or laboratory beakers (about 100 ml size, 10 cm high), foil or lid for covering the beakers · 1 ml syringes, fine needles (25 gauge), gloves · Small flasks for solvents (MEK, saline, etc.) · Chromatographic plates: ± ITLC-SG plates (Gelman No. 61886, 20 ´ 20 cm, cut into strips [1.5 ´ 10 cm]) ± Paper (Whatman 3MM No. 3030861, 20 ´ 20 cm, cut into strips [1.5 ´ 10 cm]) · Pencil for marking the strips, color pens · Scissors for cutting · Plastic tubes for the measurement of the segments · Ionization chamber For handling of radioactive samples, only single-use materials should be used in order to minimize the risk of contamination of the sample and the staff. The TLC analysis
Chapter 9 Quality Control Methods of
99m
Tc Pharmaceuticals
should be performed in an area of the hot lab with a low probability of contamination from other working procedures. If possible, a separate working area should be used. There should be a place with adequate ventilation (hood) for drying the strips after development in organic solvents (MEK, ethylacetate, etc.). The determination of the radiochemical purity of radiopharmaceuticals by ITLC requires an experienced operator to produce accurate results. Quality control should be performed daily and not on demand, when abnormal distribution or poor image quality is reported.
References Bish RE, Silverstein D, Bede JI (1980) Radiopharmaceutical-radiochromatography quality assurance with a radioisotope calibrator. J Radioanal Chem 57:565±573 Carpenter AP (1986) Radioanalytical techniques: ITLC, TLC, mini columns and electrophoresis. In: Wieland DM, Tobes MC, Mangner TJ (eds) Analytical and chromatographic techniques in radiopharmaceutical chemistry. Springer, Berlin Heidelberg New York Council of Europe (1982) Sodium pertechnetate [99mTc] injection (fission), Monograph (124). European pharmacopeia. Strasbourg Decristoforo C, Zaknun J, Kohler B, Oberladstaetter M, Riccabona G (1997) The use of electronic autoradiography in radiopharmacy. Nucl Med Biol 24:361±365 Dickey EE (1953) Separation of radium D, E and F by paper chromatography. J Chem Ed 30:525 Fairbrother JE (1984) Advances in TLC in two parts: Part 1 ± Techniques. Pharm J 10 March:293± 297; Part 2 ± Applications. Pharm J 7 July:23±28 Filthuth H (1986) Detection of radiochromatograms and electropherograms with position-sensitive wire chambers. In: Wieland DM, Tobes MC, Mangner TJ (eds) Analytical and chromatographic techniques in radiopharmaceutical chemistry. Springer, Berlin Heidelberg New York Frier M, Hesslewood S (1980) Quality assurance of radiopharmaceuticals ± a guide to hospital practice. Nucl Med Comm, Special Issue 3 Hammermaier A, Reich E, Bægl W (1986) Qualitåtskontrolle von in-vivo Radiopharmaka, ein Handbuch fçr das nuklearmedizinische Labor zur Analytik radiochemischer Verunreinigungen [in German]. ISH-Heft 94 Hæye, A (1967) Determination of radiochemical purity of some radiochemicals and pharmaceuticals by paper chromatography, thin-layer chromatography and high voltage electrophoresis. J Chromatograpy 28:379 Izmailov, N.A. Shraiber MS (1938) The application of analysis by drop chromatography to pharmacy. Farmezia 3:1 Janshold, AL, Krohn KA, Vera DR, Hines HH (1980) Design and validation of a radiochromatogram scanner with analog and digital output. J Nucl Med Tech 8:222 Levit N (1980) Radiopharmacy laboratory manual for nuclear medicine technologists. University of New Mexico College of Pharmacy Albuquerque, pp 69±80 Mallol J (1990) Analytical artifacts in quality control of Tc-99m radiopharmaceuticals. Nucl Med Biol 17:609±611 Mangner TJ (1986) Potential artifacts in the chromatography of radiopharmaceuticals. In: Wieland DM, Tobes MC, Mangner TJ (eds) Analytical and chromatographic techniques in radiopharmaceutical chemistry. Springer, Berlin Heidelberg New York Miller JM (2004) Chromatography: concepts and contrasts, 2nd edn. Wiley, New York Robbins PJ (1983) Chromatography of technetium-99m radiopharmaceuticals ± a practical guide. The Society of Nuclear Medicine, New York Stahl E (1956) Dçnnschicht-Chromatgraphie [in German]. Pharmazie 11:633 Theobald AE (1994) Quality control of radiopharmaceuticals. In: Sampson CB (ed) Textbook of radiopharmacy: theory and practice, 2nd enlarged edn. Gordon and Breach, Philadelphia Westera G, Gadze A, Horst W (1985) A convenient method for the preparation of 99m Tc(V)dimercaptosuccinic acid (99mTc(V)-DMSA). Int J Appl Radiat Isot 36:349±355 Zimmer AM, Pavel DG (1977) Rapid miniaturized chromatographic quality-control procedures for Tc-99m radiopharmaceuticals. J Nucl Med 18:1230±1233
135
136
9.1 Determination of Radiochemical Purity
9.1.2 Column Chromatography F. Rakis and J. Imre Column chromatography, or liquid chromatography, is a separation method by which a 99m Tc pharmaceutical is resolved into its components when passed through a chromatographic column with a mobile phase (solvent). Interaction of the sample with the solvent and the column matrix is affected by solubility, electrostatic forces, and charge, resulting in the retention of components on the chromatographic column and separation of impurities. Physical and chemical forces include van der Waal's, dipole, hydrogen bonding, dielectric, and electrostatic interactions, which cause separation of components with different physicochemical properties. Several separation methods were derived from liquid chromatography, depending on the choice of the stationary phase and the solvent used for a particular compound, i.e., adsorption chromatography, partition chromatography (normal or reversed phase), ion-exchange chromatography, ion-pair chromatography, gel-permeation chromatography, and affinity chromatography. For 99mTc-labeled pharmaceuticals, the most frequently used separation techniques are gel permeation chromatography at low pressure, and high-performance reversedphase, ion-pair, ion-exchange, and size-exclusion chromatography.
9.1.2.1 Limitations of Liquid Chromatography for Quality Control of 99mTc Pharmaceuticals In planar radiochromatography (thin-layer chromatography), the detection of the components of any 99mTc pharmaceutical is performed directly on the chromatographic plate; thus, the total applied 99mTc activity ± theoretically all 99mTc constituents ± can be determined, depending on sample and the system performance. In the case of column chromatographic techniques, the separated 99mTc impurities are detected indirectly, after separation, accepting incomplete sample recovery. Some components of a 99mTc pharmaceutical remain on the column. In fact, reduced, hydrolized 99mTc activity is commonly retained on the column. Since determination of radiochemical purity relies on the complete recovery of all constituents of a 99mTc pharmaceutical applied to the column, calculations based on the peak area of eluted components will overestimate the value of radiochemical purity. The retention of 99mTc radiocolloid has been determined indirectly by comparing the precolumn and postcolumn 99mTc activity, using two detection loops. However, this method depends on the accurate calibration and validation of the system. Trapping of reducing tin(II) salts (in colloidal form) in the pores of the column material has also been observed to affect radiochemical purity, because the pertechnetate content in the subsequent samples will be reduced, providing false values. These problems exclude conventional column chromatography from routine use for quality control; however, application of minicolumns has offered an alternative to thinlayer chromatography in the cases of 99mTc-hexamethylpropylene amine oxime (HMPAO) and others, discussed in the respective monographs (Part 2).
Chapter 9 Quality Control Methods of
99m
Tc Pharmaceuticals
Because of its high resolving capacity, conventional liquid chromatography is an efficient tool in research, when analysis of chemically similar byproducts (secondary, tertiary, etc., complexes), metabolites or products resulting from radiolysis, is required.
9.1.2.2 Gel Permeation or Size-Exclusion Chromatography This method is based on the accessibility of the pores in the stationary phase for 99m Tc-labeled molecules of different molecular sizes. The sample is eluted from a vertical column packed with porous beads of the gel by gravity or low pressure. Smaller 99m Tc species penetrate the pores and are retained on the column, while larger molecules are excluded and are therefore rapidly eluted from the column. This separation technique has particular application for macromolecules, proteins (serum albumin, immunoglobulins [e.g., monoclonal antibodies and their fragments]), but has also been used for separation of small-molecular-weight 99mTc-diphosphonate complexes. Quantification was performed by external scanning of the column and analysis of the activity profile of the retained 99mTc compounds (mercapto complexes, diphosphonates, etc.), using a modified thin-layer scanner. Several types of gel column filling material are available (e.g., Sephadex, Sepharose, etc.).
9.1.2.3 High-Performance Liquid Chromatography J. Imre High-performance liquid chromatography (HPLC) provides faster separation and higher resolution of the eluted components of a 99mTc pharmaceutical than does the conventional column chromatography. While in column chromatography the mobile phase passes through the stationary phase by gravity or low pressure, in HPLC the mobile phase is pumped through the column by high pressure up to 6000 psi (~ 400 bar). HPLC Instrumentation. The schematic diagram of a radio-HPLC system can be seen in Fig. 9.1.2.1.
Fig. 9.1.2.1. Components of a radio-high-performance liquid chromatography (HPLC) system
137
138
9.1 Determination of Radiochemical Purity Table 9.1.2.1. Modified silica packing materials with chemically bonded phases Type of modification
Application
C2 Dimethyl ± RP-2 C4 Butyl ± RP-4 C8 Octyl ± RP-8 C18 Octadecyl ± RP-18 C6H5 Phenyl CN, cyano NO2, nitro OH, alkanol ± DIOL NH2 amino
Reversed-phase and ion-pairing chromatography Shorter retention time than with other RP Reversed-phase and ion-pairing chromatography Separation of peptides and proteins Reversed-phase and ion-pairing chromatography Moderately to highly polar (water-soluble compounds) Reversed-phase and ion-pairing chromatography Nonpolar or moderately polar compounds Reversed-phase and ion-pairing chromatography Moderately polar compounds, polar aromatics etc. Straight- or reversed-phase chromatography Separation of compounds with double bonds Straight- or reversed-phase chromatography Straight-phase, weak anion-exchange, and reversed-phase chromatography Weakly basic anion exchanger Strongly basic anion exchanger Strongly acidic cation exchanger
N(CH3)2 dimethylamino Quaternary ammonium Sulfonic acid
The Eluent Delivery Pump. HPLC pumps deliver the mobile phase from the reservoir to the column. Mainly double piston-actuated pumps accurately deliver solvent over a broad range of flow rates (0.1 ll/min±20 ml/min). Gradient elution (flow rate or composition) can be used in HPLC separations where the use of only one mobile phase (isocratic separation) would not have achieved adequate resolution. The Sample Application Unit. In the case of radio-HPLC, the more useful system is the injector valve with a sample loop of desired volume, allowing safe filling of the 99m Tc sample. HPLC Column. In HPLC, a number of chromatographic techniques are readily available. Highly efficient HPLC columns contain small particles of less than 10 lm in diameter (greater than 20 lm for preparative HPLC), tightly packed into 100 to 300 mm length and of small internal diameter (2±5 mm) glass or steel tubes, and the result is good sample resolution and narrow peaks that elute from the column. Columns with high resolving capacity are now commercially available (Table 9.1.2.1) and can be used for several times. Packing Materials. Packing materials include modified silica with chemically bonded phases, e.g., nonpolar groups ± dimethyl, butyl, octyl, octadecyl, and phenyl; and polar groups ± amino (NH2), cyano (CN), nitro (NO2) dimethylamino [N(CH3)2], and alkanol (OH). Quaternary ammonium facilitates basic anion exchange, and sulfonic acid the acidic cation exchange, offering separation conditions for a vast variety of chemically different compounds. The use of prefilters and guard columns may considerably improve the life span of a column. Radioactivity Monitor. The homemade detector systems ± where the detector loop is placed into a well-type scintillation detector ± are frequently used (De Groot et al.
Chapter 9 Quality Control Methods of
99m
Tc Pharmaceuticals
1986 a; Nunn and Fritzberg 1986). Most commercially available radioactivity monitors use flow cells positioned between two photomultipliers with high counting efficiencies. The signal pulses from the photomultipliers are measured in coincidence to suppress noise. The signals are amplified and are then usually subjected to various data processing, integration, etc. HPLC Applications for 99mTc Pharmaceuticals. Examples of typical applications of HPLC for separation of 99mTc-labelled species are shown in Table 9.1.2.2. The most frequently used HPLC techniques (Hnatowich 1986; Millar 1989) are reversed-phase partition chromatography for nonpolar or weakly polar components of 99mTc pharmaceuticals (HMPAO [Hung et al. 1988; Neirinckx et al. 1987; Weisner et al. 1993], monodentate methoxyisobutyl isocyanide [MIBI; Carvalho et al. 1992; Hung et al. 1991], mercaptoacetyltriglycine [MAG3; Brandau et al. 1990; Coveney and Robbins 1987; Millar et al. 1990; Shattuck et al. 1994], tetrofosmin [Cagnolini et al. 1998; Graham and Millar 1999; Kelly et al. 1993], iminodiacetic acid [IDAs; Fritzberg and Lewis 1980; Nunn 1983; Nunn et al. 1983], peptides [Vallabhajosula 1986; Zinn et al. 2000], etc.), ion-pair (both ionized and less polar constituents: pertechnetate, diphosphonates; De Groot et al. 1986 b; Hoch and Pinkerton 1986; Huigen et al. 1988; Nieuwland et al. 1989; Tanabe et al. 1983, etc.), ion-exchange (ionized forms: pertechnetate, diphosphonates, etc.), and size exclusion chromatography (separation based on molecular size: diphosphonates, human serum albumin [HSA; Vallabhajosula et al. 1982], and antibodies and their fragments [Hnatowich 1986], etc.). Since HPLC is nondestructive, it can also be used as a preparative technique. The fraction containing the 99mTc pharmaceutical is formulated and applied in the clinic. Reversed-Phase Chromatography. At acidic pH, octadecylsilane (ODS or C-18)coated silica particles are frequently used as a stationary phase, although polymerbased columns (PRP-18) are also popular because of their wider operating pH range (1.0±13.0). The used mobile phases are polar solvents such as water, which is mixed with varying concentrations of miscible organics (e.g., methanol, acetonitrile). Solvent strength can be varied by changing the composition ratios of the mobile phase. Ion-Pair Chromatography. A number of 99mTc complexes are ionized by deprotonation at higher pH. It is possible to separate both ionized and nonionized 99mTc species using reversed-phase chromatography. Ionic charges can be suppressed by manipulation of pH or by the use of an ion-pair reagent. The preferred ion-pairing agents are quaternary ammonium compounds (tetrabutyl ammonium, dodecyltrimethyl ammonium, etc.) for the analysis of anionic 99mTc complexes, and N-alkyl sulfonates for HPLC of cationic 99mTc compounds dissolved in a solvent similar to that used in reversed phase method. Ion-Exchange Chromatography. In the case of 99mTc pharmaceuticals typically weak anion (e.g., amino-modified silica) or cation exchangers are used. The resolution can be affected by the ionic strength and pH of the buffered mobile phase, and gradient elution might be required to hasten elution. Gel Permeation Chromatography. 99mTc-labeled proteins on polymer-based column packing can be purified from precursor reagents and unbound radiolabeling. The first eluted macromolecules are separated according to their size from the smaller molecules.
139
140
9.1 Determination of Radiochemical Purity Table 9.1.2.2. High-performance liquid chromatography (HPLC) separation methods applied to 99m Tc pharmaceuticals Radiopharmaceutical
Column
Isocratic/ Gradient
Solvent(s)
Reference
99m Tc-HMPAO (exametazime)
C-18
Isocratic
Council of Europe 2005
PRP-1
Gradient
PRP-1
Gradient
PRP-1
Gradient
For ªAº impurity determination: A: acetonitrile B: 0.1 M phosphate buffer, pH 3.0 A : B 33 : 67 A: 20 mM phosphate buffer, pH 7.4 B: tetrahydrofuran 0±25% B over 6 min A: 10 mM potassium phosphate, pH 7.0 or water containing 1% methanol B: acetonitrile 0±50% B over 5 min A: 50 mM sodium acetate, pH 5.6 B: tetrahydrofuran 0±100% B over 17 min
C-18
Isocratic
Ccouncil of Europe 2005
C-8
Gradient
C-18
Isocratic
For ªCº impurity determination: A: acetonitrile B: 50 mM ammonium sulfate C: methanol A : B : C, 20 : 35 : 45 A: 50 mM ammonium sulfate B: methanol 0±95% B over 5 min A: methanol B: 50 mM ammonium sulfate C: acetonitrile A : B : C, 45 : 35 : 20
C-18
Isocratic with wash
C-18
Isocratic with wash
C-18
Gradient
PRP-1
Gradient
PRP-1
Isocratic
PRP-1
Isocratic
99m
Tc-MIBI (sestamibi)
99m
Tc-MAG3 (mertiatide)
99m Tc-tetrofosmin
Neirinckx 1987 Hung 1988
Weisner 1993
Carvalho 1992 Hung 1991
A: ethanol Council of B: 10 mM phosphate buffer, pH 6.0 Europe 2005 A : B 7 : 93 After 20 min, wash with methanol : water, 90 : 10 A: ethanol Millar 1990 B: 10 mM phosphate buffer, pH 6.5 A : B 5 : 95 After peak, wash with methanol±water, 90 : 10 A: 10 mM potassium phosphate Shattuck with 1% triethylamine, pH 5.0 1994 B: tetrahydrofuran 0±8% B over 30 min A: 10 mM phosphate buffer, pH 7.5 B: tetrahydrofuran 0±100% B over 17 min A: acetonitrile B: 10 mM ammonium carbonate A : B, 70 : 30 A: 5 mM monopotassium phosphate B: acetonitrile A : B, 50 : 50
Kelly 1993 Graham 1999 Cagnolini 1998
Chapter 9 Quality Control Methods of
99m
Tc Pharmaceuticals
Table 9.1.2.2 (continued) Radiopharmaceutical
Column
Isocratic/ Gradient
Solvent(s)
99m
Aminex C-18
Isocratic Isocratic
850 mM sodium acetate Tanabe 1983 10 mM sodium acetate, Hoch 1986 2 mM tetrabutylammonium hydroxide, 3% ethyl acetate, pH 6.0
99m
Aminex C-18
Isocratic Isocratic
850 mM sodium acetate 50 mM EHDP, 10 mM sodium acetate, 3 mM tetrabutylammonium hydroxide
Huigen 1988 Nieuwland 1989
99m
C-18 Isocratic Ultrasphere Isocratic ODS
25 mM phosphate buffer pH 6.0 A: 10 mM phosphate buffer, pH 6.8 B: methanol A : B 50 : 50
Nunn 1983 Fritzberg 1980
99m
Silica gel
100 mM phosphate buffer, 100 mM sodium chloride, 8 mM sodium azide 100 M phosphate buffer
Council of Europe 2005 Vallabhajosula 1982
A: 0.1% TFA in water B: 0.1% TFA/90% acetonitrile/H2O 20% B over 30 min
Vallabhajosula 1996; Zinn 2000
Tc-MDP
Tc-EHDP
Tc-IDA
Tc-HSA
Isocratic
Spherogel- Isocratic TSK SW 99m Tcdepreotide
C-18
Gradient
Reference
HMPAO hexamethylpropylene amine oxime, MIBI monodentate methoxyisobutyl isocyanide, MAG3 mercaptoacetyltriglycine, MDP methylenediphosphonate, EHDP etidronate, IDA iminodiacetic acid, HSA human serum albumin, TFA trifluroroacetic acid
The use of a dual detector system, which is a radioactive monitor with a UV detector working at 280 nm, is practical. The mobile phase is usually buffered water.
9.1.2.4 Minicolumns for Routine Quality Control There is a small-scale version of column chromatography that can compete with the planar chromatographic techniques for routine analysis of certain 99mTc pharmaceuticals. A small-sized tube or syringe is packed with appropriate stationary phase, forming a short-bed column. Several types of filling material can be used: reversed-phase packing (e.g., C18-modified silica for separation of 99mTc complexes of hepatoiminodiacetic acids ([HIDAs], MIBI, HMPAO, MAG3, etc.), preswollen gel (e.g., Sephadex for gel filtration of 99mTc-labeled HSA, immunoglobulin [HIG, monoclonal antibodies]) or aluminium oxide (for adsorption of anionic pertechnetate from inert 99mTc complexes). The 99mTc-sample is applied onto the top of the short bed and eluted with a small amount of solvent. The elution may be performed even in a plastic syringe. The separation is fast and simple, and the activity retained on the column or of the collected fractions is measured in an ionization chamber; thus, higher amounts of radioactivity of 99mTc label may be used than in the case of the planar method. The results depend on the column performance, affected by the tightness of packing and the flow rate; therefore application of standardized, prepacked columns is suggested (e.g., Chromabond, SEP-PAK) at optimal elution speed.
141
142
9.1 Determination of Radiochemical Purity
References Brandau W, Bubeck B, Schober O, Weber E, Taylor DM (1990) 99mTc-MAG3: chemistry and biokinetics of by-products. In: Blaufox MD, Hollenberg NK, Raynaud C (eds) Radionuclides in nephrourology. Karger, Basel pp 11±16 Cagnolini A, Whitener D, Jurisson S (1998) Comparison of the kit performance of three 99mTc myocardial perfusion agents. Nucl Med Biol 25:435±439 Carvalho PA, Chiu ML, Kronauge JF, Kawamura M, Jones AG, Holman BL, Piwnica-Worms D (1992) Subcellular distribution and analysis of technetium-99m-MIBI in isolated perfused rat hearts. J Nucl Med 33:1516±1522 Council of Europe (2005) European pharmacopeia. Council of Europe, Maisonneuve, Sainte-Ruffine Coveney JR, Robbins MS (1987) Comparison of technetium-99m MAG3 kit with HPLC-purified technetium-99m MAG3 and OIH in rats. J Nucl Med 28:1881±1887 De Groot GJ, Das HA, deLigny CL (1986a) A system for high performance liquid chromatography of Tc-99m complexes with on-line radiometric detection and data processing. Int J Appl Radiat Isot 37:349±355 De Groot GJ, Das HA, deLigny CL (1986b) Separation of Tc-99m(Sn)HEDP complexes by HPLC and GPC. Int J Appl Radiat Isot 37:23±27 Fritzberg AR, Lewis D (1980) HPLC analysis of Tc-99m iminodiacetate hepatobiliary agents and a question of multiple peaks: concise communication. J Nucl Med 21:1180±1184 Graham D, Millar AM (1999) Artefacts in the thin-layer chromatographic analysis of 99Tcm-tetrofosmin injections. Nucl Med Commun 20:439±444 Hnatowich DJ (1986) HPLC of radiolabelled antibodies. In: Wieland DM, Tobes MC, Manger TJ (eds) Analytical and chromatographic techniques in radiopharmaceutical chemistry. Springer, Berlin Heidelberg New York Hoch DJ, Pinkerton TC (1986) Reversed-phase HPLC of 99mTc methylene diphosphonate bone imaging kits with quantification of pertechnetate. Int J Rad Appl Instrum 37:593±598 Huigen YM, Gelsema WJ, de Ligny C (1988) Effect of the composition of the eluent in the chromatography of 99mTc-diphosphonate complexes. Int J Rad Appl Instrum 39:381±384 Hung JC, Corlija M, Volkert WA, Holmes RA (1988) Kinetic analysis of technetium-99m d,l-HM-PAO decomposition in aqueous media. J Nucl Med 29:1568±1576 Hung JC, Wilson ME, Brown ML, Gibbons RJ (1991) Rapid preparation and quality control method for technetium-99m-2-methoxy isobutyl isonitrile (technetium-99m-sestamibi). J Nucl Med 32:2162±2168 Kelly JD, Forster AM, Higley B, Archer CM, Booker FS, Canning LR, Chiu KW, Edwards B, Gill HK, McPartlin M (1993) Technetium-99m-tetrofosmin as a new radiopharmaceutical for myocardial perfusion imaging. J Nucl Med 34:222±227 Millar AM (1989) Quality assurance of radiopharmaceuticals. In: Theobald AE (1989) Radiopharmaceuticals and radiotracers in pharmacy. Ellis Horwood, Chichester, UK Millar AM, Wilkinson AG, McAteer E, Best JJK (1990) 99mTc-MAG3: in vitro stability and in vivo behaviour at different times after preparation. Nucl Med Commun 11:405±412 Neirinckx RD, Canning LR, Piper IM, Nowotnik DP, Picket RD, Holmes RA, Volkert WA, Foster AM, Weisner PS, Marriot JA, Chaplin SB (1987) Tchnetium-99m d,l-HM-PAO: a new radiopharmaceutical for SPECT imaging of regional cerebral blood flow. J Nucl Med 28:191±202 Nieuwland RJ, Das HA, de Ligny CL (1989) Improvement of the reproducibility of ion-pair HPLC of 99mTc(Sn)EHDP complexes and the influence of the Sn(II) concentration on the composition of the reaction mixture. Int J Rad Appl Instrum 40:153±157 Nunn AD (1983) Structure-distribution relationships of radiopharmaceuticals. Correlation between the reversed-phase capacity factors for Tc-99m phenylcarbamoyl-methyliminodiacetic acids and their renal elimination. J Chromatogr 255:91±100 Nunn AD, Fritzberg AR (1986) Components for the design of a radio-HPLC system. In: Wieland DM, Tobes MC, Manger TJ (eds) Analytical and chromatographic techniques in radiopharmaceutical chemistry. Springer, Berlin Heidelberg New York Nunn AD, Loberg MD, Conley RA (1983) A structure±distribution±relationship approach leading to the development of Tc-99m-mebrofenin: an improved cholescintigraphic agent. J Nucl Med 24:423±430 Shattuck LA, Eshima D, Taylor AT, Anderson TL, Graham DL, Latino FA, Payne SE (1994) Evaluation of the hepatobiliary excretion of technetium-99m-MAG3 and reconstitution factors affecting radiochemical purity. J Nucl Med 35:349±355
Chapter 9 Quality Control Methods of
99m
Tc Pharmaceuticals
Tanabe S, Zodda JP, Deutsch E, Heineman WR (1983) Effect of pH on the formation of Tc(NaBH4)-MDP radiopharmaceutical analogues. Int J Appl Radiat Isot 34:1577±1584 Vallabhajosula S, Goldsmith SJ, Pollina R, Lipszyc H (1982) Radiochemical analysis of Tc-99m human serum albumin with high pressure liquid chromatography. J Nucl Med 23:326±329 Vallabhajosula S, Moyer BR, Lister-James J, McBride BJ, Lipszyc H, Lee H, Bastidas D, Dean RT (1996) Preclinical evaluation of technetium-99m-labelled somatostatin receptor-binding peptides. JNM 37:1016±1022 Weisner PS, Bower GR, Dollimore LA, Forster AM, Higley B, Storey AE (1993) A method for stabilising technetium-99m exametazime prepared from a commercial kit. Eur J Nucl Med 20:661±666 Zinn KR, Buchsbaum DJ, Chaudhuri TR, Mountz JM, Grizzle WE, Rogers BE (2000) Noninvasive monitoring of gene transfer using a reporter receptor imaged with a high-affinity peptide radiolabeled with 99mTc or 188Re. J Nucl Med 41:887±895
9.1.3 Electrophoresis Gy. Jnoki Electrophoresis is widely used in the separation of inorganic ions and different classes of molecules. The physical principle underlying electrophoresis can be stated as: Particles carrying an electric charge are accelerated when placed in an electric field; this driving force is very rapidly balanced by the friction forces arising in the medium; from that moment, the particles move at a constant speed proportional to their charge. Electric charge carried by molecules originates either from dissociation or from selective adsorption. For polyelectrolytes such as proteins, dissociation of the acidic groups COOH or NH+3 constitutes the principal source. The electromigration rate is directly related to the charge and inversely related to the ionic radius of the complex being separated. It means that the direction of migration of cationic species is toward the cathode while the migration of the anionic species moves toward the anode. Electrophoresis has been used for quality control of certain radiopharmaceuticals (Belkas and Archimandritis 1979; Pauwels and Feitsma 1979). Paper electrophoresis has been applied successfully for the determination of the relative charge on some 99mTc complexes. HPLC, TLC, and ITLC analysis methods available today are more convenient and reproducible than electrophoresis. Despite this, electrophoresis continues to be used as a research tool in radiopharmaceutical studies. The reason for this is that electrophoresis gives information on the charge of 99mTc complexes that cannot be easily obtained by other techniques. From the standpoint of determining whether a specific radiolabeled complex is anionic, cationic or neutral, electrophoresis is the best technique currently available. In addition, polyacrylamide gels (PAGE) are used as supports for protein and macromolecular electrophoresis including radiolabeled antibodies and other proteins (Wieme 1965).
References Belkas EP, Archimandritis S (1979) Quality control of colloid and particulate 99mTc-labelled radiopharmaceuticals. Eur J Nucl Med 4:375 Pauwels EKJ, Feitsma RIJ (1977) Radiochemical quality control of 99mTc-labelled radiopharmaceuticals. Eur J Nucl Med 2:97 Wieme RJ (1965) Agar gel electrophoresis. Elsevier, Amsterdam
143
144
9.2 Determination of Tin(II)
9.2 Determination of Tin(II) F. Rakis Radiopharmaceutical kits for labeling with 99mTc eluate contain tin(II)-ion for reduction of sodium pertechnetate to lower valency states, which are chemically reactive. Tin(II) salts are easily oxidized, even by the oxygen in air. Certain chemicals are also assumed to enhance the oxidation of tin(II) to tin(IV). Therefore, determination of tin(II) in radiopharmaceutical kits is an important aspect of quality control. Classic methods for the determination of tin(II) include the titration with an iodine standard solution, or absorption measurements by spectrophotometric analysis. Both methods have considerable disadvantages for the determination of tin(II) in radiopharmaceutical kits (Rakis and Zolle 1997). A new spectrophotometric analysis of tin(II) and tin(IV) in the same matrix was developed by Rakis et al. (unpublished results); however, the disadvantages of sample preparation and the slow formation of a colored complex for absorption measurements led to the investigation of other methods. Pulse polarography has been investigated because of its speed and high selectivity. Thus, square wave voltammetry has been extended to the measurement of microgram amounts of tin(II) in radiopharmaceutical kits. Pulse polarography has offered considerable advantages for the determination of the tin(II) content in a number of radiopharmaceutical kits (Rakias et al. 1988). Square wave voltammetry shows a considerable increase in sensitivity, suitable for the measurement of very small (microgram) amounts of tin(II), as used for the reduction of 99m Tc-Na-pertechnetate when labeling radiopharmaceuticals. Two kits manufactured by NCPH±ªFredric Joliot Curieº National Research Institute for Radiobiology and Radiohygiene were examined. TromboScint and LeucoScint differ simply by the fact that LeucoScint contains twice the amount of active ingredients, i.e., 0.18 mg HMPAO and 2.28 lg tin(II). LeucoScint is used for labeling leucocytes, and TromboScint is suitable for labeling platelets. For the determination of tin(II) in kits an EG & G polarographic analyzer (model 384) with a static mercury drop electrode (model 303) and a cabinet reference electrode was used. Model 384 is a microprocessor-based polarographic analyzer with built-in floppy disk memory to store and recall analytical curves. By controlling each step of the analysis, the microprocessor automates polarographic and voltammetric measurements. All experimental parameters may be chosen by the operator. Concentrations are computed automatically and recorded in the range from 0.001 ppb to 9999 ppm. Square Wave Voltammetry of Tin(II) and Tin(IV). Deoxygenated 1 N hydrochloric acid plus 4 N ammonium chloride buffer (1 : 1, v/v) was used as an electrolyte. Sample solutions were prepared by dissolving one kit in the same buffer and adding to the electrolyte solution; recording was started from 0.0±0.6 V. The tin(IV) maximum appeared at ±0.25 V, and the tin(II) maximum at ±0.45 V, as the second peak. If only 1 N sulfuric acid is used as an electrolyte, tin(II) may be detected selectively at ±0.45 V. The method was validated, and the following parameters were examined.
Chapter 9 Quality Control Methods of
99m
Tc Pharmaceuticals
Linearity of the Instrument. To identify the highest amount of tin(II) that can be measured with a linear response, increasing concentrations of tin(II) up to 5 mg/ml were analyzed. Linear regression analysis of the data (Booster 1982) showed a correlation coefficient > 0.999, indicating linearity of measurements over a wide range of concentration. Precision of the Method. Measurements were performed with ten samples of each kit. In the case of TromboScint, the average value of Sn(II) was determined as 1.138 lg/kit (theoretically, 1.14 lg Sn(II)/vial) with a standard deviation of 0.050 lg and a coefficient of variation of 4.39%. In the case of LeucoScint, the average value of Sn(II) was calculated as 2.263 lg/kit (theoretically, 2.28 lg Sn(II)/vial), with a standard deviation of 0.089 lg and a coefficient of variation of 3.93%. Effect of Sample Volume. Since the vials were filled with 1.0 ml of the dissolved kit content in the production department, there might have been a variation in the amount of tin(II) actually added in this volume. Therefore, the precision of the method by analyzing ten matrix samples to which a homogenous solution of tin(II) chloride containing 1.14 and 2.28 lg of tin(II), respectively, were also investigated. When these known concentrations of tin(II) were analyzed together with the matrix samples, the results were identical excluding a volume effect. A recovery between 92.10 and 106.14% was observed. The average value of Sn(II) in the case of TromboScint was 1.139 lg/kit, with a standard deviation of 0.048 and a coefficient of variation of 4.21%. In the case of LeucoScint, the average value of Sn(II) was 2.266 lg/kit, with a standard deviation of 0.062 and a coefficient of variation of 2.73%. Selectivity. Although it is stated in the literature that Sn(IV) does not interfere with the measurement of Sn(II), experimental proof adding 2 lg of tin(IV) to the test solution was obtained. When no tin(IV) was added to TromboScint, the average value of Sn(II) was determined as 1.141 lg/kit, with a standard deviation of 0.068 lg and a coefficient of variation of 5.96%. With tin(IV) added to TromboScint, the average value of Sn(II) was determined as 1.126 lg/kit, with a standard deviation of 0.055 lg and a coefficient of variation of 4.88%. Values demonstrating no interference by Sn(IV) were also shown for LeucoScint. Based on the above-cited results, square wave voltammetry is suitable for the measurement of microgram amounts of tin(II) in radiopharmaceutical kits, with high accuracy (> 99%). Impurities causing oxidation to tin(IV) have been shown to have no effect on the recovery. Based on the obtained data, square wave voltammetry has been shown as a reliable and highly sensitive method for the determination of tin(II) in radiopharmaceutical kits.
References Booster P (1982) Statistische Methoden im Laboratorium [in German]. Elsevier, Amsterdam Eckelman W, Meinken G, Richards P (1971) Chemical state of Tc-99m in biomedical products. J Nucl Med 12:596±600 Rakis F, Zolle I (1997) Stannous ion determination: importance and relevance for radiopharmaceutical kits. In: Bergmann H, Kroiss A, Sinzinger H (eds) Radioactive isotope in clinical medicine and research, vol. 22. Birkhauser, Basel, pp 401±409
145
146
9.3 Sterility Testing of Radiopharmaceuticals Rakias F, Kelemen-Kçttel I, Tæmpe P, Nemeth P, PaaI TL (1988) Correlation between the Sn(II)content of phosphonate, phytate, and gluconate kits and the quality of the obtained images. In: Hæfer R, Bergmann H (eds) Radioactive isotope in clinic und research, vol. 18. Schattauer, Stuttgart, pp 417±419
9.3 Sterility Testing of Radiopharmaceuticals S. R. Hesslewood It is an integral feature of good manufacturing practice that radiopharmaceuticals for injection that are required to be sterile are prepared under conditions that exclude microbial contamination of the product. There is a higher degree of assurance of sterility of products that are terminally sterilized in their final container than for those that are prepared by aseptic technique. The majority of radiopharmaceuticals in current clinical practice fall into the latter category, and a sterility test is the only analytical method available to demonstrate the absence of microbial contamination. However, the use of commercially available sterile products and starting materials (e.g., kits) with marketing authorization is an important feature in avoiding problems with lack of sterility. A test for sterility is laid down in the European Pharmacopeia for all parenteral products, and two techniques for testing are described, either membrane filtration of the product with subsequent incubation of the filter in suitable culture media (which is the preferred technique), or direct inoculation of the product into the culture medium, followed by incubation at the appropriate temperature for the specified time. Suitable media are described in the European Pharmacopeia; although, it is also recognized that other media may be used. In every case, however, it is necessary to demonstrate that the medium is capable of supporting the growth of microorganisms both in the presence and absence of the material to be tested.
9.3.1 Problems in Applying the European Pharmacopeia Test to Radiopharmaceuticals There are specific difficulties in applying the test as written, particularly for radiopharmaceuticals based on technetium-99m, and these difficulties are acknowledged in the general pharmacopeial monograph on radiopharmaceuticals. First, the batch size of products is often small, and in the case of a technetium product prepared in a hospital or clinic, may consist of only a single vial with a total volume of less than 10 ml. This makes it impossible to follow the European Pharmacopeia requirements for the number of containers to be tested (10% or 4, whichever is the greater), without preparing extra vials of the product specifically for the test, which is economically unrealistic and also imposes an additional radiation burden on to the operators. There are also problems with the volume of the product available for testing. The European Pharmacopeia states that if the quantity in the container is between 4 and 20 ml, which is common for technetium products, 2 ml should be used for each culture medium being tested. If followed strictly, this would mean a large reduction in the volume of material available for patient use.
Chapter 9 Quality Control Methods of
99m
Tc Pharmaceuticals
Second, the radioactive nature of the product imposes handling difficulties in performing the test, since quality control departments may not have the necessary facilities for handling radioactive materials, and radiopharmacy departments may not be suitably equipped to perform sterility testing. One method to avoid these problems would be to let the product decay for a sufficient period of time to allow the level of radiation emitted to fall to a suitably low level to facilitate handling. However, there is published evidence to suggest this technique will decrease the sensitivity of the test, since the number of any viable organisms in the preparation may decrease on storage (Brown and Baker 1986; Stathis et al. 1983; Wind 1985). It is therefore always necessary to perform a sterility test as soon as possible after preparation of the radiopharmaceutical. Finally, it is recognized that for short-lived radiopharmaceuticals, the long incubation time of the culture media (7 days for the membrane filtration technique, 14 days for direct inoculation) means the result of the sterility test cannot be available before the product is used. In these situations, the test constitutes a control of production techniques and will give valuable information about their suitability.
9.3.2 Recommendations for Sterility Testing of Radiopharmaceuticals In view of the difficulties in applying the European Pharmacopeia test, many variations have been adopted. Whatever the technique used, it is essential to perform a validation to ensure that it would be able to detect the presence of any viable microorganisms in the sample. If following the European Pharmacopeia test, it is often easier to perform the direct inoculation technique. It is suggested that the remnants of a technetium vial are divided equally between two suitable culture media as soon as possible after expiration of the radiopharmaceutical. The inoculated media should then be incubated for not less than 14 days at 20±25 8C for media being used to detect fungi, or 30±35 8C for those used in the detection of bacteria. Depending on the level of radioactivity present, shielding of the culture media may be necessary during some or all of the incubation period. When macroaggregates or microspheres are being tested, it may be necessary to perform a subculture at the end of the incubation mixture, since, dependent on the volume used in the test, the radiopharmaceutical itself may produce turbidity in the culture medium that may be indistinguishable from bacterial growth. The membrane filtration technique is technically more elaborate and requires that the radiopharmaceutical under test, after aseptic dilution, is passed through a membrane filter with a pore size of 0.45 m, which has been moistened with a sterile nutrient diluent. After filtration, the membrane is either transferred to a suitable culture medium or aseptically cut into two equal parts and one half placed in each of two suitable media. Incubation at the appropriate temperature is required for at least 7 days. An alternative ± although unofficial ± technique that has been used is the addition of an equal volume of double-strength culture medium directly to the remnants of the vial of radiopharmaceutical immediately upon its expiration. The advantages and disadvantages of this technique are summarized in Table 9.3.1. In order to make the test more meaningful, it is necessary to rotate the culture media used and ensure that each product prepared is at some stage tested with each culture me-
147
148
9.4 Pyrogen Testing of Radiopharmaceuticals Table 9.3.1. Sterility testing with double-strength broth Advantages
Disadvantages
No delay in testing Can be performed in radiopharmacy Container can be easily shielded No dilution of culture medium below normal strength
Sample size variable Only one culture medium can be used Not officially recognized Not applicable if preservatives need to be diluted out
dia used. After incubation for 14 days, the result is obtained by observing the culture medium for turbidity. A positive control can then be performed by inoculating one of the test organism described in the European Pharmacopeia directly into the vial. Again, it is necessary to ensure the test organisms are used in rotation for each product.
9.3.3 Frequency of Testing It has already been stated that the results of a sterility test are necessarily retrospective and as such, constitute a control of production processes within the radiopharmacy department rather than forming a part of a release procedure for individual products. Sterility testing of every batch prepared, although ideal, is unrealistic in practice. The testing program should ensure that, at some stage, all different types of product prepared are tested on a regular basis. At least one batch should be tested every week. In addition, it is recommended that the remnants of the first eluate of each technetium generator and the final unused eluate should be tested.
9.4 Pyrogen Testing of Radiopharmaceuticals The European Pharmacopeia requires certain radiopharmaceuticals, mainly of biological origin, to comply with a test for pyrogens, which are substances generally arising from bacteria that are capable of inducing fever. The British Pharmacopeia general monograph on parenteral products states that compliance is necessary for preparations where the volume in a single injection exceeds 15 ml or is less than 15 ml, but where the label says the product is apyrogenic. The test consists of measuring the rise in body temperature in rabbits, following intravenous administration of the substance and in order to pass the summed response from three rabbits must not exceed 1.15 8C. The Pharmacopeia also considers that for some products it may be necessary to allow decay to take place before testing in order that hyperthermia that may be due to the radioactivity of the product is avoided. In view of the sophisticated facilities required for the test and the fact that volumes of radiopharmaceuticals administered are hardly ever above 15 ml, this test is not carried out in hospitals or clinics. If necessary, samples can be submitted to specialist laboratories for testing, although it is most unlikely that this will take place routinely. For short-lived materials, the results are inevitably retrospective to the use of the product, which limits its usefulness. For some products, a direct measurement of the level of bacterial endotoxins in the preparation is required. The test uses a lysate of amoebocytes from the horseshoe crab,
Chapter 9 Quality Control Methods of
99m
Tc Pharmaceuticals
Table 9.4.1. Products in the European Pharmacopeia with endotoxin limits Product
Endotoxin limit (units ml±1)
99m
Not Not Not Not Not
Technetium human albumin Iodine 123 MIBG Iodine 131 MIBG Iodine 131 norcholesterol Indium 111 pentetate
greater greater greater greater greater
than than than than than
175/V a 175/V 175/V 175/V 14/V
MIBG metaidobenzoguanidine a V maximum recommended dose in milliliters
Limulus polyphemus, and is often referred to as Limulus amoebocyte lysate (LAL) test. It depends on the fact that endotoxins will produce turbidity, precipitation or, more commonly, gelation of a solution of the lysate within a period of approximately 1 h. The test is described in detail in the European Pharmacopeia and requires the performance of control experiments to demonstrate the sensitivity of the lysate using at least three dilutions of an endotoxin standard. It is also necessary to show that the product under test does not contain substances that interfere with the sensitivity of the test. Reagents for performing the test are commercially available and in view of the time scale required, can be used prospectively for short-lived radiopharmaceuticals, although technical expertise in performing the test is essential to avoid obtaining misleading results. Products in the European Pharmacopeia for which a bacterial endotoxin test is specified are listed in Table 9.4.1, together with the limits for bacterial endotoxin laid down in the monographs. This limit is the maximum allowable endotoxin concentration in units per ml. The United States Pharmacopeia prescribes for a wider range of radiopharmaceuticals, including those based on positron emitters. The maximum limits prescribed are the same as in the European Pharmacopeia. It is known that endotoxins are approximately 1000 times more toxic following intrathecal as opposed intravenous administration and this is recognized in the pharmacopeial monographs for products used intrathecally (e.g. Indium In111-pentetate) since the maximum amount of endotoxin allowed is lower than for intravenous products.
9.4.1 Recommendations for Endotoxin Determinations of Radiopharmaceuticals The use of commercially available products with marketing authorization that have been tested by the manufacturer will remove the need for routine determination of endotoxins. However, testing should be considered if it is thought that a particular product may be giving rise to problems. When products are prepared totally within a hospital from raw materials, the hospital assumes responsibility for their safety, quality, and efficacy. In these situations, each batch of a product, especially those intended for intrathecal administration, should be tested.
149
150
9.4 Pyrogen Testing of Radiopharmaceuticals
References Brown S, Baker MH (1986) The sterility testing of dispensed radiopharmaceuticals. Nucl Med Commun 7:327±336 Stathis VJ, Miller CM, Doerr GF, Coffey JL, Hladik WB (1983) Effect of technetium Tc-99m pertechnetate on bacterial survival in solution. Am J Hosp Pharm 40:634±637 Wind K (1985) Sterility testing. In: Cox PH (ed) Radiopharmacy and radiopharmacology, yearbook 1. Gordon and Breach, London, pp 35±46
Chapter 10
10
Other Technetium Isotopes: 94m Tc as a Potential Substitute in Positron Emission Tomography Investigations Z. Kovcs
10.1 Introduction Among the neutron-deficient isotopes of Tc, 94mTc seems to have suitable nuclear properties for application in positron emission tomography (PET) (Browne and Firestone 1986). Considering the relatively new lipophilic Tc-labeled flow tracers used in cardiac perfusion imaging (2-methoxyisobutyl isocyanide [MIBI], teboroxime, tetrofosmin) it would be reasonable to replace 99mTc with 94mTc in order to carry out quantitative investigations of biodistribution and clearance with PET. With this replacement, the pharmacokinetics of useful Tc compounds could be studied in a number of cases, which would enhance the introduction of new 99mTc-labeled pharmaceuticals into clinical practice. The labeling and quality control methods are well known and partly subject of this book. Our task is to review the different methods for the production of 94m Tc and also the separation technique from irradiated targets.
10.2 Methods of Production The 52-min half-life positron emitter 94mTc (b+ = 70%, Eb+ = 2.5 MeV; EC = 30%, Ec = 871.1 keV, Ic = 94.2%) was first suggested and produced from natural Mo in 1991 (Nickles et al. 1991; Ræsch and Beyer 1991). Low-energy (up to 13 MeV) proton and deuteron irradiations were carried out on metal and MoO3 targets and led to low yields (1.7 and 3.9 Ci/lA at 1-h irradiations) with high contamination from other Tc isotopes. Detailed systematic investigations were carried out in recent years at Jçlich (Denzler et al. 1995; Faûbender et al.1995; Qaim et al. 1994; Ræsch and Qaim 1993), using highly enriched target materials. Excitation functions were measured by the stacked foil technique (Qaim et al. 1977; Weinreich et al. 1974) for the 94Mo(p,n)94mTc reaction up to 18.4 MeV (Ræsch and Qaim 1993), and the 93Nb(3He,2n) 94mTc reaction up to 35 MeV (Faûbender et al.1995). The 92Mo(a,2n)94Ru ? 94mTc and 92Mo(a,pn)94mTc reaction routes were also studied (Denzler et al. 1995). The excitation functions were measured on 93.9% enriched Mo metal samples (Qaim et al. 1994). The highest yield is given by the 94Mo(p,n) reaction, with an acceptable level of impurity. This is the method of choice at small cyclotrons. However, if higher-energy a-particles are available (Ea > 30 MeV), the 92Mo(a,2n) reaction can provide extra clean 94mTc with a considerably higher yield than that given in Table 10.1.
152
10.3 Methods of Separation Table 10.1. Comparison of
94m
Tc production routes
Nuclear reaction
Optimal energy range (MeV)
Thick target yields at EOB (MBq/lAh)
Major impurities at EOB (%)
94
13 ? 7
2000
94g
93
18 ? 10
34
94g
Mo(p,n)94mTc Nb(3He,2n)94mTc Mo(a, 2n)94Ru ?94mTc
Tc (6) Tc (24) Tc (14)
93m,g
92
26* ? 18
35
None
92
26* ? 18
98
94g
Mo(a, pn)94mTc
Tc (30)
*maximum available energy at the compact cyclotron in Jçlich
10.3 Methods of Separation Several methods have been published for the separation of 94mTc from irradiated 94 MoO3 target (Nickles et al. 1993 a, b; Ræsch et al. 1994). In an online method, a wellfocused, vertical 11-MeV proton beam was used for irradiation (Nickles et al. 1993 a). The 94MoO3 target was melted by the beam and kept at 800 8C, under continuous surface temperature control. Ninety-five percent of the radiotechnetium, heated out simultaneously, was collected on a cooled quartz tube. One milligram of 94MoO3 also was evaporated and adsorbed on the surface, from which the 94mTc was separated and purified by a wet chemistry method. Offline thermochromatographic separation was used in another method (Ræsch et al. 1994). The irradiated 94MoO3 target was placed at the bottom of a vertically arranged thermochromatographic system and heated to 1,090 8C. Both the 94MoO3 and the 94mTc rapidly evaporate in a stream of wet air carrier gas. The 94MoO3 condenses in the 800±600 8C zone, and the H94mTcO4 in the 350±250 8C temperature range on the quartz column. The H94mTcO4 layer was dissolved from the surface in NaOH and purified on an alumina column. After purification, no Mo traces or other chemical forms of radiotechnetium could be detected. The yield is 40±45% after a 25-min separation time. The batch yields of 94mTc amount to about 50 mCi (18 GBq). The final product was of the highest radionuclidic purity reported so far. A method has also been described for the recovery of highly enriched 94MoO3, with 95% yield (Ræsch et al. 1994). The final chemical form of the radiotechnetium with both separation methods is 94m TcO±4, which is suitable for labeling procedures. An alternate method is described in (Nickles et al. 1993 b). A Mo foil (0.1 mm thick) was used for irradiation and the radiotechnetium was extracted by an electrochemical etching procedure. With the obtained 94mTc-pertechnetate, 94mTc-teboroxime was prepared, which was used for the first preliminary human investigation with this 94mTc-labeled pharmaceutical (Nickles et al. 1993 b). Another PET study with 94mTc-2-methoxy isobutyl isonitrile was also reported (Stone et al. 1994).
Chapter 10 Other Technetium Isotopes
References Browne E, Firestone RB (1986) Table of radioactive isotopes. Wiley, New York Denzler F, Ræsch F, Qaim SM (1995) Excitation functions of a-particle induced nuclear reactions on highly enriched 92Mo: comparative evaluation of production routes for 94mTc. Radiochim Acta 68:13±20 Faûbender M, Novgorodov AF, Ræsch F, Qaim SM (1995) Excitation functions of 93 Nb(3He,xn)93m,g;94m,g;95m,g; Tc processes from threshold up to 35 MeV: possibility of production of 94mTc in high radiochemical purity using a thermochromatographic separation technique. Radiochim Acta 65:215±224 Nickles J, Nunn AD, Stone CK, Perlmann SB, Levine RL (1991) Tc-94m flow agents: bridging PET and SPECT. J Nucl Med 32:925 Nickles RJ, Christian BT, Nunn AD, Stone CK (1993 a) Cyclotron production of high-purity 94mTc by in situ sublimation. J Labelled Compd Radiopharm 23:447 Nickles RJ, Nunn AD, Stone CK, Christian BT (1993 b) Technetium-94m-teboroxime: Synthesis, dosimetry and initial PET imaging studies. J Nucl Med 34:1058±1066 Qaim SM, Stæcklin G, Weinreich R (1977) Excitation functions for the formation of neutron deficient isotopes of bromine and krypton via high-energy deuteron induced reactions on bromine: production of 77Br, 76Br and 79Kr. Int J Appl Radiat Isot 28:947±953 Qaim SM, Ræsch F, Scholten B, Stæcklin G, Kovcs Z, Trknyi F (1994) Nuclear data relevant to the production of medically important b+-emitting radioisotopes 75Rb, 86Y, 94mTc and 124I at a small cyclotron. Dickens JK (ed) Proceedings of International Conference for Science and Technology. Gatlinburg, Tenn., pp 1035±1038 Ræsch R, Beyer G-J (1991) Långerlebige Positronenemitter: Einzelnuklide und Generatorsysteme, Produktion am Rossendorfer Zyklotron U-120, radiochemische Studien und Mæglichkeiten fçr die PET, Report ZfK-745 [in German] Ræsch F, Qaim SM (1993) Nuclear data relevant to the production of the positron emitting technetium isotope 94mTc via the 94Mo(p,n)-reaction. Radiochim Acta 62:115±121 Ræsch F, Novgorodov AF, Qaim SM (1994) Thermochromatographic separation of 94mTc from enriched molybdenum targets and its large scale production for nuclear medical application. Radiochim Acta 64:113±120 Stone CK, Christian BT, Nuckles RJ, Perlman SB (1994) 94mTc-methoxy isobutyl isonitrile dosimetry and resting cardiac imaging with PET. J Nucl Cardiol 1:425 Weinreich R, Schult O, Stæcklin G (1974) Production of 123I via the 127I(d,6n) 123Xe(b+,EC)123I process. Int J Appl Radiat Isot 25:535±543
153
Chapter 11
The Rules Governing Medicinal Products for Human Use in the European Union
11
A. Verbruggen, I. Zolle
11.1 European Economic Council Directives and Regulations The peaceful application of nuclear reactors after World War II initiated the production of large quantities of radionuclides, which were introduced to medicine for the investigation of human physiology and disease. The application of radioactive tracers for clinical diagnosis and therapy increased by the year, resulting in the widespread use of radioisotopes in clinical procedures. Radioactivity has been the concern of physicists, who set up rules and regulations for the protection of the general public and health personnel handling radioactive materials. At most institutions, the commercially available radiopharmaceuticals were managed by a responsible staff of health physicists. In some European countries, the distribution of radioactive compounds to the users was considered the responsibility of the pharmacist. The first centralized isotope pharmacy was installed in Denmark, taking responsibility for the quality and distribution of radioactive drugs since 1976. Different combinations of primary legislation for nonradioactive drugs (i.e., the Medicines Act) and national administrative arrangements provided legislation for consumer protection regulating the importation, manufacture, and sale or supply of radioactive medicinal products (Appendix A.2). Requirements for good radiopharmacy practice and specific guidelines for simple procedures such as handling of ready-for-use radiopharmaceuticals and the preparation of 99mTc-labeled radiopharmaceuticals from generators and kits were presented in a comprehensive report by Kristensen (1979) based on existing good manufacturing practice (GMP) recommendations and standards applied to the manufacture of pharmaceuticals (Appendix A.3). The demand on qualified personnel, and premises for small-scale production in a radiopharmacy posed a considerable challenge. The European regulatory bodies have three main instruments to reach an approximation of national regulations: directives, guidelines, and European regulations. · Directives are rules addressed to the member states to be translated into the respective national legislation and effectively implemented. Directives are mandatory. · Guidelines are recommendations for the effective implementation of directives by the member states. Guidelines are not mandatory. · The European regulations are mandatory in all European Union countries; they are applied into the national legislation without translation. In 1989, the European Economic Council issued Directive 89/343/EEC as an amendment to Directive 75/319/EEC, which, for the first time, defines different classes of radiopharmaceutical products and states the requirements for marketing authorization of these products as proprietary medicinal products for human use (Appendix A.1). Implementation of directives into national law provides legislation that is effective in all member states, resulting in a harmonization within the European Union.
156
11.1 European Economic Council Directives and Regulations
The comprehensive legislation regulating all medicinal products in the European Union is organized in seven volumes in The Rules Governing Medicinal Products in the European Union: · Volume 1 contains the directives governing medicinal products for human use in the European Union. · Volume 2 contains the notice to applicants for marketing authorization of medicinal products. · Volume 3 contains the guidelines concerning quality, safety, and efficacy. · Volume 4 contains pharmaceutical legislation of GMP for the manufacture of medicinal products. · Volumes 2, 3, and 4 present specific guidelines for radiopharmaceutical products. · Volumes 5, 6, and 7 are dedicated to medicinal products for veterinary use. Council directives relating to marketing authorization of medicinal products for human use and amending texts are listed in Volume 2B (annex). Some directives relevant for radiopharmaceuticals as medicinal products are discussed here in chronological order. Directive 65/65/EEC is the basis of all pharmaceutical regulations. It includes relevant definitions (medicinal product, proprietary medicinal product, officinal and magisterial formula, etc.) and states the registration by law for all proprietary medicinal products. Since 1965, this directive has been amended several times. Directives 75/318/EEC and 75/319/EEC, amended at different times from the original version, state the documents and requirements for manufacture and marketing authorization. Definition of the professional profile of the qualified person responsible for the quality of medicinal products is presented, and a technical body on medicines, the Committee of Proprietary Medicinal Products (CPMP), is created. Due to technical reasons, some products such as vaccines and sera, homeopathics, hemoderivatives, and radiopharmaceuticals were excluded from the scope of this directive in its original version. In 1987, Directive 87/22/EEC created the centralized marketing authorization of medicines, particularly those derived from biotechnology in accordance with the CPMP, as a valid procedure for drug registration in all member states. This centralized procedure should be applied to relevant new medicinal products, such as those obtained by biotechnology, monoclonal antibodies, or radionuclides. Therefore, radioactive medicinal products were recognized in this context as drugs, requiring the modification of Directives 65/ 65/EEC, 75/318/EEC and 75/319/EEC to extend their provisions to the products previously excluded; this amendment was introduced by Directive 89/341/EEC. After Directive 89/341/EEC had been issued, a block of directives, so-called extension directives, extended the scope of Directives 65/65/EEC, and 75/319/EEC to vaccines and sera, homeopathics, hemoderivatives, and radiopharmaceuticals, giving specific details for them. This means that all pharmaceutical directives must be applied to these products. One of these extension directives is 89/343/EEC, extending the scope of the pharmaceutical directives to radiopharmaceuticals, defining all radiopharmaceutical products (radiopharmaceuticals ready for use, cold kits, generators, and radionuclide precursors) as drugs for which marketing authorization as proprietary medicinal products for human use is required. However, this authorization shall not be required for radiopharmaceuticals prepared at the time of use, if prepared by using authorized products (cold kits, generators, and radionuclide precursors) and in accordance with the instructions given by the manufacturer. This directive does not derogate in any way the rules on radiation protection.
Chapter 11 The Rules Governing Medicinal Products for Human Use
Directive 91/356/EEC gives the principles of GMP detailed in Volume 4 of The Rules Governing Medicinal Products in the European Union. These principles must be applied not only for production at industrial level, but also for small-scale productions, such as in nuclear medicine. A new block of directives gives details on practical aspects for the rational use of medicinal products. Directive 92/25/EEC concerns the distribution from the producer to the dispenser. According to this directive, distribution of medicinal products must be in accordance with good distribution practice (GDP): only approved products may be distributed, and may be delivered exclusively to persons authorized for supplying the public in the concerned country. Directive 92/26/EEC states the criteria to be applied for the supply of medicinal products to the public. According to these criteria, radiopharmaceuticals are medicinal products for human use, dispensed only on medical prescription. In most European countries, the only persons authorized to dispense medicinal products are pharmacists, but radioactive medicinal products may constitute an exception to this rule in some countries. Council Regulation 2309/93 creates the European Agency for the Evaluation of Medicinal Products (EMEA), in London, as administrative authority responsible for medicines in all European countries. The CPMP and the centralized marketing authorization of medicinal products are both assumed by this agency. In addition to pharmaceutical regulations, the radioactive nature of radiopharmaceuticals is also regulated by European Directives. Directives from European Atomic Energy Community (EURATOM) (Directive 84/466 and 84/467) regulate the health protection of patients submitted to ionizing radiation and of the general public and workers against the dangers of ionizing radiation. Since radiopharmaceutical products are included in the scope of the discussed pharmaceutical directives, regulations applied to nonradioactive medicines equally apply to radiopharmaceuticals.
11.1.1 Application for Marketing Authorization Marketing authorization for medicinal products, i.e., radiopharmaceuticals, is required for importation, manufacture, and sale in the European Union. Presentation and content of the dossier is contained in the rules governing medicinal products in the European Union: The Rules Governing Medicinal Products in the European Union, Notice to Applicants, Volume 2B: Medicinal Products for Human Use. The requirements for the content of the application dossier are stated in Directive 75/318/EEC as amended, i.e., the documents and data in support of the application for marketing authorization pursuant to Article 4 of Council Directive 65/65/EEC must be organized in a file in four parts, containing: · Part I, summary of the dossier · Part II, chemical, pharmaceutical and biological documentation describing the composition and method of preparation of the medicinal product (raw materials, manufacture, characteristics of the labeled compound, quality control, European Pharmacopeia standards), and the documentation of preclinical studies performed in animals to determine stability and the elimination kinetics (half-times of removal) · Part III, toxicopharmacological documentation
157
158
11.1 European Economic Council Directives and Regulations
· Part IV, clinical documentation of the clinical investigations carried out in humans to demonstrate efficacy and safety These are the classic requirements for any medicinal product demonstrating quality, safety, and efficacy. The Summary of Product Characteristics (SPC) is a document specific for any medicinal product. The SPC is included in Part I of the Dossier for Marketing Authorization. After obtaining marketing authorization, the SPC is officially approved and describes the characteristics and uses of the authorized product. For each approved radiopharmaceutical, the SPC states relevant information concerning pharmaceutical form, approved clinical indications, posology, internal dosimetry and the effective radiation dose resulting from approved diagnostic procedures, detailed instructions for kit labeling, a method to verify the radiochemical purity after labeling before administration, the shelf-life, etc. These indications and instructions cannot be modified by the user; any relevant modification, such as a new clinical indication, a modification in the posology or a change in the composition or pharmaceutical form, or any modification in the instructions for labeling, requires a new authorization granted by the same authority that authorized the first application. As a result of regulations by directives and guidelines, all practical aspects related to a radiopharmaceutical are strictly governed by pharmaceutical rules: production, marketing authorization, distribution, clinical investigation, clinical use, etc.
11.1.2 Industrial Production The industrial producer of a radiopharmaceutical product (radiopharmaceuticals ready for use, generators, radionuclide precursors, cold kits) must be authorized as pharmaceutical laboratory. The person responsible for the production is a qualified person, pharmacist, or any equivalent academic (e.g., chemist, biochemist, biologist) with a pharmaceutical professional profile. This person is responsible for the starting materials, production, quality control, etc., and ensures the characteristics of the final products as stated in the approved requirements and characteristics or stated in the European Pharmacopeia. The production must be performed in agreement with GMP. The quality and conformity of radiopharmaceuticals produced in any country of the European Union are guaranteed by their producer. For radiopharmaceuticals produced outside the European Union, it is necessary that a qualified person within the European Union (re)controls the product and ensures its correct production and quality. Only officially authorized radiopharmaceuticals may be distributed within the European Union.
11.1.3 Marketing Authorization The registration process is necessary for production, sale, and use of a medicinal product, including radiopharmaceuticals. There are two registration procedures, depending on the type of marketing authorization that is intended. National authorization is valid in the particular member state where
Chapter 11 The Rules Governing Medicinal Products for Human Use
an application has been submitted. However, if marketing authorization is intended in the entire European Community, a centralized procedure must be applied by submitting an application to EMEA in London. Presentation and content of the dossier is contained in the rules governing medicinal products in the European Union: The Rules Governing Medicinal Products in the European, Notice to Applicants, Volume 2A: Procedures for Marketing Authorization. The requirements for the content of the application dossier are stated in Directive 65/65/EEC, as amended, and in Regulation (EEC) No. 2309/93. The marketing authorization is granted after positive evaluation of the file. The authorization states all characteristics of the medicinal product, specified in the registration file and in the SPC. Any change in the approved characteristics needs a new authorization.
11.1.4 Sales and Distribution The distribution of medicinal products is regulated by the rules of GDP. According to that, only approved medicinal products may be distributed, and delivered exclusively to persons authorized for dispensing. In most countries, these persons are the pharmacists. However, in some countries radioactive compounds do constitute an exception to this rule, and have to be delivered directly to the physicians who use them for diagnostic or therapeutic purposes in patients (nuclear medicine physicians and radiotherapists). The distribution mode is very important for the withdrawal from the market of any product if necessary (lack of the required quality, unexpected adverse effects, etc.).
11.1.5 Pharmacovigilance Pharmacovigilance is a system for the urgent notification to the health authorities of any adverse effect observed in relationship to any medicinal product. Pharmacovigilance encompasses surveillance of side effects after short-term and long-term use of medicines. During the first 5 years of a new drug being put on the market, pharmacovigilance is particularly important, as comparatively little is known about its safety profile until it has been exposed to a much wider range of patients than is possible through clinical trials. Pharmacovigilance is obligatory for producers, but in some countries it is obligatory for all involved health professionals as well. Radiopharmaceuticals are included in the scope of pharmacovigilance. In each country, there is a national system for reporting adverse reactions. However, there is also a European Rapid Alert System, within the activities of the EMEA, to facilitate the transmission of incidents of pharmacovigilance.
11.1.6 Other Aspects Other aspects concerning the preparation, distribution and use of radiopharmaceuticals are also subject to pharmaceutical regulations, such as pricing, labeling, and advertising, etc.
159
160
11.1 European Economic Council Directives and Regulations
Despite strict legislation, frequently observed deviations do exist, such as delivery of radiopharmaceuticals to nonauthorized persons, application of nonapproved radiopharmaceuticals, application of radiopharmaceuticals for nonapproved clinical indications or using higher doses than authorized, and labeling of kits under different conditions than recommended by the manufacturer, etc.
11.1.7 SPC for Radiopharmaceutical Products The authorized sequence of topics for the presentation of product information (package leaflet) according to Guideline III/9163/89, reissued 10/25/1993 are listed in Table 11.1.1.
Table 11.1.1. Authorized sequence of topics for the presentation of product information (package leaflet) according to European Economic Committee Guideline III/9163/89 Heading no.
Name
1 2
Name of the Product (Trade Name) Qualitative and Quantitative Composition 2.1 Active Substance(s) 2.2 Physical Characteristics Pharmaceutical Form Clinical Particulars 4.1 Clinical Indications 4.2 Posology and Method of Administration 4.3 Contraindications 4.4 Special Warnings and Special Precautions for Use 4.5 Interactions with Other Medicaments 4.6 Pregnancy and Lactation 4.7 Effects on the Ability to Drive and Use Machines 4.8 Undesirable Effects 4.9 Overdose Pharmacological Properties 5.1 Pharmacodynamic Properties 5.2 Pharmacokinetics Properties 5.3 Preclinical Safety Data 5.4 Radiation Dosimetry Pharmaceutical Particulars 6.1 List of Excipient(s) 6.2 Incompatibilities 6.3 Shelf-life 6.4 Special Precautions for Storage 6.5 Nature of Contents of Container 6.6 Instructions for Use/Handling (Labeling and QC Methods) 6.7 Holder of the Marketing Authorization Marketing Authorization Holder Marketing Authorization Number Date of First Authorization/Renewal
3 4
5
6
7 8 9
Chapter 11 The Rules Governing Medicinal Products for Human Use
11.2 The European Pharmacopeia A. Verbruggen
11.2.1 General A pharmacopeia (from the Greek words pharmakon [drug] and poeioo [to work, to manufacture] is a collection of standardized specifications that define the quality of pharmaceutical preparations, their constituents, or even their containers. It is an official book stating not only the necessary characteristics of medicinal products, described in monographs, but also including monographs on methods of analysis, reagents, pharmaceutical forms, and other related items. The specifications described in pharmacopeias are not recommendations but are obligatory. Within the European Union, the official pharmacopeia is the European Pharmacopeia (Ph. Eur.) from the Council of Europe. In most countries it is used as such, in some other countries it constitutes the basis for the national version of the pharmacopeia. The official texts of the Ph. Eur. are published in English and French. Translations in other languages may be prepared by the signatory states of the European Pharmacopeia Convention. In case of doubt or dispute, the English and French versions are alone authoritative. The monographs of the Ph. Eur. are legally enforced in the countries being signatories to the Convention on the Elaboration of a European Pharmacopeia. The terminology used in the marketing authorization dossiers must be identical to that of the Ph. Eur. Likewise, raw materials, preparations, dosage forms of medicines and, if necessary, containers, must comply with the requirements of the Ph. Eur. The Ph. Eur. was inaugurated in 1964 through a convention elaborated under the aegis of the Council of Europe. The eight founder countries were Belgium, France, Federal Republic of Germany, Italy, Luxembourg, the Netherlands, Switzerland, and the United Kingdom. It was considered that the free movement of medicines, for reasons of public health as well as international trade, requires that manufacturing and quality control standards be unified for pharmaceutical substances for human and veterinary use and that these standards keep pace with scientific progress. For this reason, the initiative was taken for unifying national pharmacopeias. Adherence to the Ph. Eur. should guarantee that the citizens of Europe receive the same quality of medicines. As of start of 2006, the European Pharmacopeia Convention has been signed by 35 parties including the European Union and the following countries: Austria, Belgium, Bosnia and Herzegovina, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, the Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Ireland, Iceland, Italy, Latvia, Lithuania, the Grand-Duchy of Luxembourg, Malta, Norway, the Netherlands, Portugal, Serbia and Montenegro (formerly Yugoslavia), Romania, the Slovak Republic, Slovenia, Spain, Sweden, Switzerland, Turkey, and the United Kingdom. In addition, 16 observers participate at a lower level, namely the WHO, four European states (Albania, Georgia, Poland, Ukraine), and 11 non±European states (Algeria, Australia, Canada, China, United States [Food and Drug Administration], Madagascar, Malaysia, Marocco, Senegal, Syria, Tunisia). The quality standards of the Ph. Eur. have, therefore, an impact on the quality of medicines, which goes far beyond the European region. In absence of a description of
161
162
11.2 The European Pharmacopeia
a particular medicinal product in the Ph. Eur., other relevant pharmacopeias may be considered, such as the United States Pharmacopeia (USP). The new European Directives 2001/82/EC and 2001/83/EC on medicines for human use and veterinary use maintain the mandatory character of the Ph. Eur. monographs in the preparation of dossiers for marketing authorization of medicines, which was instituted in the first directive, Directive 75/318/EEC in 1975. It means that the monographs of the Ph. Eur. must therefore be updated to keep pace with products on the market, with scientific progress, and with regulatory developments.
11.2.2 Monographs on Radiopharmaceuticals in the Ph. Eur. The Ph. Eur. defines requirements for purity and activity for a wide range of radiopharmaceutical products, whether they are used for therapeutic or diagnostic purposes. As of the beginning of 2006, there are: · Two general monographs: ± Radiopharmaceutical preparations (01/2005 : 0125). This monograph describes the principles and methods to be applied in the respective paragraphs of the individual monographs, e.g., how to measure the half-life of a radionuclide. ± 5.7. Table of physical characteristics of radionuclides mentioned in the Ph. Eur. (01/2005:50700) · 56 monographs on a specific radiopharmaceutical, of which: ± 46 monographs on non±positron emission tomography (PET) radiopharmaceuticals · 18 99mTc preparations · 11 radiopharmaceuticals labeled with iodine-123 or iodine-131 · Preparations labeled with 32P, 89Sr, 3H, 51Cr, 57Co, 58Co, 67Ga, 111In, 81mKr, 201Tl, or 133 Xe ± 10 monographs on radiopharmaceuticals labeled with a positron emitting radionuclide The requirement to guarantee the quality and to analyze radiopharmaceuticals according to the specifications set in these monographs applies to every producer within the countries adhering to the Ph. Eur. More specifically, this means that: · For radiopharmaceuticals delivered to the (radio)pharmacist, nuclear medicine physician, or radiotherapist in a ready-to-use form (such as 201TlCl, 18FDG, 131I-capsules, 123I-iodide for radiolabeling, etc.), the manufacturer has to perform the analyses as described in the monographs. · Radiopharmaceuticals prepared in a nuclear medicine department using licensed labeling kits (mostly 99mTc-labeled preparations) need not to be analyzed after their preparation according to the Ph. Eur. monograph, but rather, follow the instructions in the package leaflet. In most cases, this means a rather simple check of the radiochemical purity and in some cases, of the pH. However, if for any reason a full analysis is required (e.g., in case of serious side effects), these preparations must meet all requirements of the monograph. · There are no monographs on labeling kits. Part of the quality control of licensed or locally produced labeling kits is that the manufacturer (industrial or in radiopharmacy) verifies whether their labeling according to the instructions results in a prep-
Chapter 11 The Rules Governing Medicinal Products for Human Use
aration that meets the requirements of the corresponding Ph. Eur. monograph on the radiolabeled preparation. · Up to now unlicensed radiopharmaceuticals (e.g., 11C-raclopride, 18F-fluoride for bone scintigraphy, etc.) the manufacturer, i.e., the local radiopharmacy, has to perform a full analysis according to the monograph of the Ph. Eur. In its introductory general statements, the Ph. Eur. mentions that a preparation is not of Ph. Eur. quality unless it complies with all the requirements stated in the monograph. This does not imply that performance of all the tests in a monograph is necessarily a prerequisite for a manufacturer in assessing compliance with the Ph. Eur. before release of a product. The manufacturer may obtain assurance that a product is of Ph. Eur. quality from data derived, for example, from validation studies of the manufacturing process and from in-process controls. Parametric release in circumstances deemed appropriate by the competent authority is thus not precluded by the need to comply with the Ph. Eur. ªCompetent authorityº means the national, supranational, or international body or organization vested with the authority for making decisions concerning the issue in question. It may, for example, be a national pharmacopeia authority, a licensing authority, or an official control laboratory. In practice, this means that the local pharmaceutical inspector has the right to decide whether or not particular tests of a monograph have to be performed before release of the product, unless the monograph specifies the reverse (as it is the case with the tests for sterility and bacterial endotoxins of radiopharmaceutical preparations for injection labeled with a shortlived radionuclide). As a result, there is no uniform rule with respect to the possibility of applying a parametric release of radiopharmaceuticals throughout Europe and a variety of attitudes in this respect exists. Harmonization of this situation in the European Union would be more than welcome. The introductory general statements of the Ph. Eur. also clarify that the tests and assays described are the official methods upon which the standards of the Ph. Eur. are based. With the agreement of the competent authority (again), alternative methods of analysis may be used for control purposes, provided that the methods used enable an unequivocal decision to be made as to whether compliance with the standards of the monographs would be achieved if the official methods were used. In the event of doubt or dispute, the methods of analysis of the Ph. Eur. are alone authoritative.
11.2.3 Elaboration of New Ph. Eur. Monographs on Radiopharmaceutical Preparations Monographs on radiopharmaceutical preparations are elaborated by Expert Group 14 of the European Pharmacopeia Commission, i.e., the group on radioactive compounds. Groups of experts are appointed by the Commission (the organ that takes all final decisions) for a renewable period of 3 years. The experts appointed to such groups are chosen for their personal competence on the proposal of their national delegations. The competent authority of each member state may propose one appointed member for each group of experts, taking account of the competence of the person proposed for the work involved. In addition, subject to approval by the Commission, specialists in a particular field (e.g., PET radiopharmaceuticals) may assist the appointed experts when supplementary technical advice is needed. At this moment, Group 14 has one expert
163
164
11.2 The European Pharmacopeia
from 11 European countries, three additional specialists in the field of PET-radiopharmaceuticals, a scientific officer from the European Pharmacopoeia Commission and a president. The elaboration of a new monograph (or the revision of an existing monograph) on a radiopharmaceutical preparation requires several steps according to a strict procedure: · The European Pharmacopeia Commission agrees on the elaboration of a new monograph or the revision of an existing monograph by Group 14; proposals concerning the introduction of monographs, general chapters, and other texts into the Ph. Eur. may be made by the chair of the Commission, a national delegation, or a group of experts through the intermediary of its chair. · The Group designates a rapporteur and, if necessary, a corapporteur for the monograph to be elaborated. · The European directorate for the quality of medicines (EDQM), in charge of the secretariat of the European Pharmacopeia Commission, is responsible initially for finding and compiling information, and it asks the manufacturers and suppliers for samples for analysis and in some cases, for use as reference substances. In the case of radioactive compounds, the samples are sent directly to the experts, as the laboratory of the EDQM is not allowed to handle radioactivity. · The expert rapporteur initiates the required work, if necessary, with the collaboration of manufacturer(s), user(s), the corapporteur, and possibly other members of Group 14. · Based on the laboratory results, the rapporteur elaborates a first draft according to the Technical Guide for the Elaboration of Monographs and the Style Guide of the Ph. Eur. The Technical Guide explains the principles that govern the elaboration of European monographs, and it can also be used in preparing registration files. It is continually being revised and updated. As an example, the Technical Guide specifies that, preferentially, liquid chromatography (LC) must be used for control of organic impurities, and thin-layer chromatography should be reserved for control of specific impurities that cannot conveniently be controlled by LC or gel chromatography. The aim of the Style Guide is to provide the means of drafting clear unambiguous texts, with similar requirements presented in the same way in every monograph. It is considered that a uniform style is of great help in conveying information in an easily understandable and unambiguous manner. An analyst who has already carried out a test prescribed in the Ph. Eur. will find it easier to set up and carry out a similar test presented in the same way. · The draft monograph is discussed within Group 14 in one or mostly several sessions. The Group examines the text and if necessary, carries out additional experimentation which may involve the participation of the EDQM laboratory (only for work not involving radioactivity). · Once a consensus is reached within the group of experts, the monograph (in English and French) is subjected to an international public survey procedure which takes 6 months and involves the national pharmacopeia authorities of the member states and all the readers of Pharmeuropa. Pharmeuropa is the official journal of the EDQM (four issues per year) and aims to be a forum for the publication of draft texts or monographs elaborated by the Ph. Eur. groups of experts, and the regular presentation and communication of general policy. The issues also include information on forthcoming conferences and
Chapter 11 The Rules Governing Medicinal Products for Human Use
training courses, public inquiries, news and updates on texts undergoing international harmonization, and scientific notes. It allows the users in the field to share their experience and give their views and input on monographs and other texts being elaborated by Ph. Eur. groups of experts. · The comments received during the public survey are discussed and examined within Group 14, and the monograph is amended if necessary. · Once the monograph has gone through these various steps, it is submitted to the European Pharmacopeia Commission for adoption. · The Commission also proposes the date for common entry into force, which is ratified by a resolution of the Public Health Committee of the Council of Europe. Apart from the elaboration of new monographs, existing texts are regularly updated, taking into account the changes in marketed products, scientific progress, comments from users, and authorities. Such revisions are made at the request either of a public health authority or of an industrialist, one of the delegations or the chair of the group of experts.
11.3 European Union Legislation Concerning New Drug Development A. Verbruggen
11.3.1 EU Commission Directives and Guidelines On 1 May 2004, EU Directive 2001/20/EC (European Parliament and of the Council of the European Union) came into force in the European countries, laying down the principles of good clinical practice (GCP) in the conduct of clinical trials on medicinal products for human use. At this moment, the provisions of this directive have been transposed into national laws in most European member states, while complementary guidance documents on the submission, content, and format of clinical trial applications (CTAs) have been issued by the EU Commission (European Commission 2003 a, b; European Medicines Agency 2004). In addition, EU Directive 2005/28/EC (European Commission 2005) was published on 8 April 2005, which not only defined the principles and detailed guidelines for GCP regarding investigational medicinal products for human use, but also set out the requirements for authorization of the manufacturing or importation of such products. As a consequence of the new legislation for clinical trials, documentation on the quality and preclinical (i.e., toxicological) data of investigational medicinal products, including radiopharmaceuticals, needs to be submitted to obtain approval from the national health authorities in the member states prior to initiating a clinical study in humans. Furthermore, all clinical trials which started in the European Union after 1 May 2004 need to be recorded in the European EudraCT database (European Commission 2003 b).
165
166
11.3 European Union Legislation Concerning New Drug Development
11.3.2 Clinical Trials Clinical trials are studies to evaluate the effectiveness, pharmacokinetics, and safety of medications or medical devices by monitoring their effects on large groups of people. Clinical research trials may be conducted by government health agencies, researchers affiliated with a hospital or university, independent researchers, or private industry. The use of an approved medicinal product in nonapproved conditions (different administration route, dose, clinical indications, etc.) requires also a new clinical trial. All clinical trials must be carried out according to a protocol approved by an ethical committee and according to the GCP rules. Participants must be volunteers. Clinical trials with radiopharmaceuticals must be performed in suitable patients rather than in healthy people in order to avoid any unnecessary exposure to radiation. In addition, administrative authorization is needed in some countries, as well as other specific requirements. Only results obtained by authorized clinical trials may be used in support of a clinical indication for an application for marketing authorization. According to the pharmaceutical legislation and European guidelines related to CTAs, a written approval should also be obtained for the clinical data (i.e., study protocol) related to a specific CTA. However, although evaluation and approval of the study protocol are generally being performed by the independent (leading) ethics' committee, some exceptions do exist in certain countries. In any case, for multicenter clinical trials, approval for the quality, safety, and efficacy of the investigational drug product should be sought in every country involved in the trial. Since Directive 2001/20/EC was translated into country-specific national laws, the quality requirements for medicinal products such as radiopharmaceuticals used in clinical studies often differ to a certain extent from one country to another. In fact, the same holds true for the current legislation regarding preparation, dispensing, and use of radiopharmaceuticals, radioactive precursors, or radionuclides that are routinely used in hospitals for diagnostic or therapeutic purposes. In addition, the scope of the national legislation, which is based on the definition of an investigational medicinal product, may also differ from the scope of the corresponding EU legislation and therefore may have substantial impact on the clinical research in each member state.
11.3.3 CTA Requirements Evidently, the existing differences in the EU countries relating to the regulatory documentation required for CTAs using radiopharmaceuticals often provide additional administrative burden, in particular in the case of multicentric studies, and are often experienced by (non)academic investigators as ªoverregulationº from the national health authorities. In addition, the currently available chemical-pharmaceutical quality requirements for investigational radiopharmaceutical products are covered by the general EMEA draft guideline regarding investigational medicinal products in clinical trials (European Medicines Agency 2004), which provides only a limited level of detailed guidance for ready-to-use compounds (e.g., 67Ga-citrate), kit-based radiopharmaceuticals (e.g. 99mTc-mertiatide), or PET radiopharmaceuticals (e.g., 18F-fludeoxyglucose). Subsequently, this lack of detailed information often leads to considerable uncertainty and misinterpretation by professionals in this particular research field who are regu-
Chapter 11 The Rules Governing Medicinal Products for Human Use
larly faced with substantial difficulties when seeking approval from the national authorities to allow the start of a clinical study (e.g., due to submission of insufficient or inappropriate quality data). Another point of concern relates to the impact of the new legislation on clinical trials performed by noncommercial research centers. Many academic research centers developing new radiopharmaceuticals might not have the necessary regulatory experience or time to compile a CTA according to the current European requirements, and often do not have the facilities or budget to produce small batches of radioligands for clinical use under full GMP conditions. Moreover, a lot of confusion still seems to exist at the academic level on the liabilities of the investigator and sponsor. Evidently, the currently existing difficulties and uncertainties experienced by academics impede the broader development and clinical use of new radiopharmaceuticals in Europe, and of course, the marketing of such investigational drug products. An even bigger lack of clarity is experienced by professionals in the field concerning the regulations to be followed for the manufacturing, dispensing, and use of radiopharmaceuticals or radionuclides that are being prepared in hospital radiopharmacies or centralized radiopharmacies for daily clinical practice in hospitals. In most cases, it concerns formulations for intravenous use that are prepared in house due to the short half-life of the used radioisotope, under the responsibility of a qualified person (QP). As a consequence, a variety of procedures are being used across European countries, since a lot of uncertainty still exists on the requirements with respect to preparation conditions, quality of starting materials, analyses of the finished product to be performed, as well as on the technical profile of the qualified person.
Acknowledgment The authors thank Dr. Christophe Lahorte for the useful discussions and his valuable information, which contributed significantly to the content of this chapter.
Appendix A.1 List of European Economic Council Directives and Regulations Applied to Radiopharmaceuticals These documents are available in the current version at http://dg3.eudra.org/eudralex Council Directive 65/65/EEC of 26 January 1965, on the approximation of provisions laid down by law, regulation, or administrative action relating to medicinal products Council Directive 75/318/EEC of 20 May 1975, on the approximation of the laws of member states relating to analytical, toxicopharmacological and clinical standards, and protocols in respect of the testing of medicinal products Council Directive 75/319/EEC of 20 May 1975, on the approximation of provisions laid down by law, regulation, or administrative action relating to medicinal products Directive 87/22/EEC of 22 December 1986, on the approximation of national measures relating to the placing on the market of high-technology medicinal products, particularly those derived from biotechnology (centralized marketing authorization of medicines) Council Directive 89/341/EEC of 3 May 1989, amending Directives 65/65/EEC, 75/318/EEC and 75/ 319/EEC, on the approximation of provisions laid down by law, regulation, or administrative action relating to proprietary medicinal products Council Directive 89/343/EEC of 3 May 1989, extending the scope of Directives 65/65/EEC and 75/ 319/EEC, and laying down additional provisions for radiopharmaceuticals
167
168
Appendix Commission Directive 91/356/EEC of 13 June 1991, laying down the principles and guidelines of good manufacturing practice for medicinal products for human use Council Directive 92/25/EEC of 31 March 1992, on the wholesale distribution of medicinal products for human use Council Directive 92/26/EEC of 31 March 1992, concerning the classification for the supply of medicinal products for human use Council Regulation (EEC) No 2309/93 of 22 July 1993, laying down Community procedures for the authorization and supervision of medicinal products for human and veterinary use and establishing a European Agency for the Evaluation of Medicinal Products Committee of Proprietary Medicinal Products (CPMP) Note for guidance III/9163/89, reissued 25 October 1993, summary of the product characteristics Council Directive 84/466/EURATOM of 3 September 1984, laying down basic measures for the radiation protection of persons undergoing medical examination or treatment Council Directive 84/467/Euratom of 3 September 1984, amending Directive 80/836/EURATOM, regarding the basic safety standards for the health protection of the general public and workers against the dangers of ionizing radiation A.2 Good Practice in the Manufacture of Pharmaceuticals (from Kristensen 1979) Basic standards of good manufacturing practice for pharmaceutical products (1972) Report PHI/ 72, EFTA Secretariat, Geneva Good practice in the manufacture and quality control of drugs (1977) World Health Organization, Resolution WHO 28.65, WHO Chronicle 31 (Suppl.) Guidelines for the manufacture of sterile products, annex to the basic standards of good manufacturing practice for pharmaceutical products (1973) Report PHI/73, EFTA Secretariat, Geneva Guide to good pharmaceutical manufacturing practice (1977) Department of Health and Social Security (HMSO), London Manual on radiation sterilization of medical and biological materials (1973) Technical Reports Series No. 149. International Atomic Energy Agency, Vienna Hygiene Recommendations (1972) Drug manufacturers association, Stockholm (Dec. 1972) United States Food and Drug Administration, Code of Federal regulations, Title 21, Part 210±211 A.3 Good Radiopharmacy Practice (from Kristensen 1979) Kristensen K (1975) The quality of radiopharmaceuticals. A review of current problems in quality factors in nuclear medicine. 13th international meeting of the Society of Nuclear Medicine. Copenhagen, pp 135.1±135.17 Kristensen K (1979) Preparation and control of radiopharmaceuticals in hospitals. Technical Reports Series No. 194. International Atomic Energy Agency, Vienna Kristensen K, Mçller T, Rhodes BA (1977) Good radiopharmacy practice, quality control in nuclear medicine. Mosby, St. Louis, Mo., pp 268±275 Good pharmaceutical manufacturing practice applied to the hospital preparation of radiopharmaceuticals (1977) Dept. of Health and Social Security, notes for guidance issued by the Medicines Inspectorate, London Good practice in the manufacture of radiopharmaceuticals (1971) A proposal put forward by a group of pharmacists from the Nordic countries. Arch Pharm Chem 78:1002±1009 Guidelines for the preparation of radiopharmaceuticals in hospitals (1975) British Institute of Radiology, London, Special Report No. 11 Hospital Physicists` Association (1976) The hospital preparation of radiopharmaceuticals. Scientific Report Series 16 Isotope Pharmacy (1976) On the preparation of Tc-99m labelled radiopharmaceuticals. Rep. IA-5, Copenhagen Trott NG (1978) The preparation of radiopharmaceuticals in hospitals. In: Hæfer R, Bergmann H (eds) Radioactive isotopes in clinical medicine and research, vol. 13. Egermann, Vienna, pp 517±528
Chapter 11 The Rules Governing Medicinal Products for Human Use
References European Commission (2003 a) Detailed guidance for the request for authorization of a clinical trial on a medicinal product for human use to the competent authorities, notification of substantial amendments and declaration of the end of the trial. (http://pharmacos.eudra.org/F2/ pharmacos/docs/Doc2005/10_05/CA_14-2005.pdf) European Commission (2003 b) Detailed guidance on the European clinical trials database (EudraCT Database). http://pharmacos.eudra.org/F2/pharmacos/docs/Doc2003/april/cp-guidanceeudract_ 230403.pdf) European Commission (2005) Commission Directive 2005/28/EC of 8 April 2005 laying down principles and detailed guidelines for good clinical practice as regards investigational medicinal products for human use, as well as the requirements for authorisation of the manufacturing or importation of such products. European Medicines Agency (2004) CPMP/CHMP/QWP185401 Draft guideline on the requirements to the chemical and pharmaceutical quality documentation concerning investigational medicinal products in clinical trials. (http://www.emea.eu.int/Inspections/docs/18540104en.pdf) European Parliament and the Council of the European Union (2001) Directive 2001/20/EC of the European Parliament and of the Council of 4 April 2001 on the approximation of the laws, regulations and administrative provisions of the Member States relating to the implementation of good clinical practice in the conduct of clinical trials on medicinal products for human use. (http://pharmacos.eudra.org/F2/eudralex/vol-1/DIR_2001_20/DIR_2001_20_EN.pdf) Kristensen K (1979) Preparation and control of radiopharmaceuticals in hospitals. Technical Reports Series No. 194. International Atomic Energy Agency, Vienna
169
Part II
Chapter 12
Monographs of 99mTc Pharmaceuticals 12.1
12
99m
Tc-Pertechnetate
I. Zolle and P. O. Bremer Chemical name
Chemical structure
Sodium pertechnetate Sodium pertechnetate 99mTc injection (fission) (Ph. Eur.) Technetium Tc 99m pertechnetate injection (USP) 99m Tc(VII)-Na-pertechnetate
Pertechnetate anion (99mTcO±4)
Physical characteristics
Commercial products
Ec = 140.5 keV (IT) T1/2 = 6.02 h
99
Mo/99mTc generator: GE Healthcare Bristol-Myers Squibb Mallinckrodt/Tyco
Preparation Sodium pertechnetate 99mTc is eluted from an approved 99Mo/99mTc generator with sterile, isotonic saline. Generator systems differ; therefore, elution should be performed according to the manual provided by the manufacturer. Aseptic conditions have to be maintained throughout the operation, keeping the elution needle sterile. The total eluted activity and volume are recorded at the time of elution. The resulting 99mTc activity concentration depends on the elution volume. Sodium pertechnetate 99mTc is a clear, colorless solution for intravenous injection. The pH value is 4.0±8.0 (Ph. Eur.).
Description of Eluate 99m
Tc eluate is described in the European Pharmacopeia in two specific monographs depending on the method of preparation of the parent radionuclide 99Mo, which is generally isolated from fission products (Monograph 124) (Council of Europe 2005 a), or produced by neutron activation of metallic 98Mo-oxide (Monograph 283) (Council of Europe 2005 b). Sodium pertechnetate 99mTc injection solution satisfies the general requirements of parenteral preparations stated in the European Pharmacopeia (Council of Europe 2004). The specific activity of 99mTc-pertechnetate is not stated in the Pharmacopeia; however, it is recommended that the eluate is obtained from a generator that is eluted regularly,
174
12.1
99m
Tc-Pertechnetate
every 24 h. Details for obtaining carrier-free technetium from the 99Mo/99mTc generator and the resulting radionuclidic purity of eluates are discussed in Chap. 5, Sect. 5.1.1. Pertechnetate anion (99mTcO±4) is stable in aqueous solutions. It is chemically not reactive; its ability to form ligand complexes depends on the reduction to lower valence states (Steigman and Eckelman 1992; Steigman and Richards 1974; Steigman et al. 1975). The major use of this short-lived radionuclide in nuclear medicine to date is for the ad hoc preparation of 99mTc pharmaceuticals, which is performed with kits containing stannous ion as a reducing agent (Johannsen and Narasimhan 1992; Lin and Winchell 1972; Lin et al. 1971).
Clinical Applications 99m
Tc(VII)-pertechnetate is used after intravenous injection: · Thyroid scintigraphy ± Determination of technetium uptake and morphology ± Diagnosis and localization of hot/cold nodules · Salivary gland scintigraphy ± To asses salivary gland function and duct status · Imaging of gastric mucosa ± To diagnose ectopic gastric mucosa (Meckel's diverticulum) · Brain scintigraphy ± Visualization of brain lesions when the blood-brain barrier (BBB) is defective · Lachrimal duct scintigraphy ± To evaluate nasolachrimal drainage · In vivo labeling of RBC ± Regional blood pool imaging ± First-pass cardiac radionuclide angiography (ejection fraction, wall motion) ± Detection of occult gastrointestinal bleeding Sodium pertechnetate Tc-99m was introduced for scanning the thyroid (Harper 1964) and for brain scanning (McAfee et al. 1964; Quinn 1965), primarily because of its physical properties; other applications followed (Harper et al. 1966). The striking similarity of the heptavalent anion with iodide, however, has made pertechnetate an excellent radionuclide for thyroid scanning and for the study of thyroid physiology (Andros et al. 1965; Kusic et al. 1990). In vivo labeling of red blood cells (RBC) with sodium 99mTc-pertechnetate (Callahan et al. 1982) is performed subsequent to pretreatment of RBC in vivo with a stannous reducing agent, using stannous pyrophosphate cold kits (TechneScan PYP, AngioCis) as well as Amerscan Stannous Agent.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Time of Examinations · Thyroid scintigraphy is performed 20 min after intravenous injection. · Salivary gland scintigraphy should begin immediately after intravenous injection and at regular intervals up to 60 min. · Meckel's diverticulum scintigraphy should commence immediately after intravenous injection and at regular intervals up to 30 min. · For brain scintigraphy, sequential images are taken immediately within the first minute after intravenous injection; static imaging is performed 1-h later. · Lachrimal duct scintigraphy's dynamic imaging should begin immediately after tracer application for 10 min. · For in vivo RBC labeling, the blood pool scintigraphy should start 10 min after intravenous injection of a bolus of 99mTc-pertechnetate: cardiac dynamic imaging should begin immediately, and abdominal imaging should also begin immediately and at various times up to 24 h. Recommended Activities for Indications. The activity range for intravenous administration in patients (70 kg) is: · Thyroid scintigraphy: 75 MBq · Salivary gland scintigraphy: 40 MBq · Meckel's diverticulum: 185 MBq · Brain scintigraphy: 550 MBq, after blocking thyroid and choroid plexus to avoid nonspecific uptake of 99mTc-pertechnetate · Lachrimal duct scintigraphy: 2±4 MBq instilled into each eye · In vivo RBC labeling: 740 MBq, after pretreatment with a stannous agent Pediatric Dose. The amount of radioactivity for infants and children administered for myocardial scintigraphy is based on body weight, using the scaling factors given in Appendix 1 (Table A1.2). The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
Additional Information Iodinated contrast agents or iodine-containing medication interfere with 99mTc-pertechnetate thyroid imaging. Persistent vascular activity of 99mTc-pertechnetate has been observed when scintigraphy has been performed following a bone scan, due to radiolabeled RBC that had retained stannous ions (Ancri et al. 1977; Montelibano et al. 1979). Several drugs interfere with the normal biodistribution of 99mTc-pertechnetate (Hladik et al. 1987). Thus, cancer chemotherapeutic agents (methotrexate) can affect brain scintigraphy; atropine, isoprenaline, and analgesics interfere in abdominal imaging; iodine and other blockers (perchlorate, perrhenate) can modify thyroid uptake.
175
176
12.1
99m
Tc-Pertechnetate
Quality Control Radiochemical Purity. Sodium pertechnetate [99mTc] must satisfy the requirements stated in the European Pharmacopeia (Council of Europe 2004 a). More than 95% of 99m Tc activity must be present as pertechnetate anion. Paper Chromatography. The European Pharmacopeia describes descending paper chromatography using methanol/water (80 : 20 v/v) as solvent; developing time is 2 h. The 99mTc-pertechnetate anion migrates with an Rf value of 0.6. More than 95% of the measured radioactivity corresponds to an Rf of 0.6; less than 5% are detected at the start. Recommended Methods by the Manufacturer Thin-layer chromatography Stationary phase: Solvent: Developing time:
Gelman ITLC-SG (fiberglass), 2 ´ 9.5 cm Saline (0.9% NaCl) 10 min
Rf values:
99m
Tc reduced, hydrolized: Tc-Na-pertechnetate:
99m
0.0±0.1 0.9±1.0 (>99%)
Thin-layer chromatography on silica gel plates offers reliable results faster; 99mTc-pertechnetate migrates with the solvent (saline) front; reduced, hydrolized activity remains at the start. The results of radiochemical purity generally exceed 99%. Radionuclidic Purity. The European Pharmacopeia and national regulatory agencies recommend determination of 99Mo in the primary eluate to assure high quality of generator eluates (DIN 6854). Generators are eluted after shipment, before administration of eluates to patients. The primary eluate contains the highest concentration of chemical impurities and of carrier 99Tc (decay product). Also, parent 99Mo is highest in the first eluate (Hammermayer et al. 1986). Less than 0.1% of the total 99mTc activity is due to parent 99Mo, and not more than 0.01% is due to other radionuclidic impurities. These limits are however, never observed with the available generator systems. Determination of 99Mo Impurity. Determination of 99Mo should be performed with a sample of the fresh eluate (37 MBq) by c-spectrometry. A lead absorber 6-mm thick is placed between the sample and the NaI-detector. The fraction of c-radiation measured at 740 keV (99Mo) should not exceed the reading obtained with a reference (99Mo) of 37 kBq. The purity of generator eluates is directly related to the performance of a generator system (see Chap. 5, Sect. 5.1.1).
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Pharmacokinetic Data The monovalent anion pertechnetate is actively transported into the thyroid in a manner similar to iodide; however, it is not metabolized and is released from the thyroid unchanged. It has been demonstrated that the active transport of iodide and pertechnetate share the same carrier mechanism (Wolff and Maurey 1962). Uptake in the thyroid gland is between 1.5 and 2% of the injected activity within 20 min (Andros et al. 1965). Assuming an activity of 74 MBq for thyroid scintigraphy, the concentration of pertechnetate in blood has been calculated as 2.5 ´ 10±12 M, based on a volume of distribution of 20 l. This concentration is far below the value required to saturate the carriermediated uptake mechanism. However, iodinated contrast agents or iodine-containing medication do affect serum levels of iodide (up to 3 ´ 10±4 M) and thus would interfere with 99mTc-pertechnetate thyroid imaging (Loberg 1979). In blood, 70±80% of 99mTc-pertechnetate is bound to proteins. Perchlorate has been shown to displace pertechnetate from plasma protein-binding sites (Oldendorf et al. 1970). The unbound fraction is preferentially concentrating in the thyroid gland and other related structures, such as salivary glands, gastric mucosa, choroid plexus, and mammary tissue. 99mTc-pertechnetate is selectively excluded from the cerebrospinal fluid (Andros et al. 1965). Elimination of 99mTc-pertechnetate from plasma after intravenous or oral administration (same subject) showed disappearance curves with an initial fast elimination of radioactivity; 50±60% are cleared with a half-time of 15 min; the remainder is eliminated more slowly, with half-times of approximately 3 h. After oral administration, the highest value of 99mTc activity in blood was reached within 30 min; the activity level was approximately one half of the radioactivity measured at the same and subsequent times after intravenous injection (Andros et al. 1965). The rates of disappearance for both whole blood and plasma were shown to be the same (Prince et al. 1980). Pertechnetate is excreted by the kidneys, but other pathways may be relevant in specific circumstances, such as saliva, gastric juice, milk, sweat, etc. (Hays 1973). Lactating women secrete 10% of pertechnetate in milk (Ahlgren et al. 1985). Pertechnetate crosses the placental barrier. A major difference between the kinetics of pertechnetate and iodide in humans is the excretion pattern; only pertechnetate is excreted in the feces (Andros et al. 1965; Hays and Berman 1977). Renal excretion by glomerular filtration is observed in the first 24 h after administration; 25±30% of the injected activity is recovered in the urine. During the following 48±72 h, fecal excretion predominates and may amount to 35% of the injected radioactivity. A total of approximately 60% of the administered radioactivity is recovered in urine and feces in 72 h; approximately 40% is retained in the body, mainly in the digestive tract. The whole-body biological half-time is estimated to be 53 h (Andros et al. 1965). Tubular reabsorption of pertechnetate was determined as 86.5% of the filtered amount. 99mTc-pertechnetate is excreted unchanged (Dayton et al. 1969).
177
178
12.1
99m
Tc-Pertechnetate
In certain clinical situations, when thyroidal uptake of 99mTc-pertechnetate should be avoided, pretreatment with an oral dose of potassium perchlorate is used to inhibit uptake. Perchlorate anion shows greater affinity for the transporter than does iodide and is, therefore, a competitive inhibitor of the thyroid iodide trap (Wolff and Maurey 1962). Like pertechnetate, perchlorate is concentrated in the thyroid and is not metabolized. Assuming 100% resorption of an oral dose of 300 mg of KClO4 and an initial distribution volume of 20 l, the resulting concentration of perchlorate in blood is approximately 10±4 M, sufficient for saturation of the thyroid trapping mechanism (Loberg 1979). The effect of pretreatment with perchlorate and iodide on pertechnetate pharmacokinetics has been studied (Oldendorf et al. 1970; Prince et al. 1980; Welch et al. 1969). 99m
Tc-pertechnetate cannot pass through the intact BBB, but in areas of the brain where structural defects permit diffusion, uptake has been used as an indicator of vascular and neoplastic brain lesions (Jhingram and Johnson 1973). 99m
Tc-pertechnetate has an affinity for RBC that have been treated (in vivo) with a reducing agent, causing ªstannous loadingº. Approximately 95% of the administered 99m Tc activity is taken up by RBC. Unbound pertechnetate is excreted by the kidneys. Approximately 15% of the activity is excreted in the urine during the first day (Porter et al. 1983). Radioactivity is removed from blood with a half-time of 60 h by renal excretion (International Commission on Radiological Protection 1987).
Radiation Dose The radiation exposure after the intravenous administration of 99mTc-pertechnetate depends on the thyroid status, and whether a blocking agent has been administered. The thyroid gland, stomach wall, small intestine, upper and lower intestinal wall, and urinary bladder wall are the most exposed organs. The effective (whole body) dose equivalent for pertechnetate 99mTc is 0.013 mSv/MBq (International Commission on Radiological Protection 1987). The effective dose in adults (70 kg) resulting from 75 MBq of intravenously injected 99mTc-pertechnetate for thyroid scintigraphy is approximately 1 mSv. The absorbed radiation dose to the thyroid (without a blocking agent) resulting from an intravenous injection of 75 MBq of 99m Tc-pertechnetate corresponds to 1.7 mGy. The effective dose in adults (70 kg) resulting from 40 MBq of intravenously injected 99m Tc-pertechnetate for salivary gland scintigraphy is approximately 0.5 mSv. Lachrimal duct scintigraphy using 4 MBq of 99mTc-pertechnetate corresponds to an effective dose of 0.05 mSv. The absorbed radiation dose to the optical lens is given as 0.038 mGy/MBq. Using 4 MBq of 99mTc-pertechnetate, the absorbed radiation dose to the lens corresponds to 0.15 mGy. Diagnosis of ectopic gastric mucosa using 185 MBq of intravenously injected technetate corresponds to an effective dose of approximately 2.4 mSv.
99m
Tc-per-
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
The effective dose in adults (70 kg) resulting from 550 MBq of intravenously injected 99m Tc-pertechnetate for brain scintigraphy (after blocking thyroid and choroid plexus) is approximately 2.9 mSv. The effective (whole body) dose equivalent (with blocking agent) is 0.0053 mSv/MBq. 99m
Tc-Labeled Erythrocytes. The effective (whole body) dose equivalent for 99mTc-labeled erythrocytes is 0.0085 mSv/MBq (International Commission on Radiological Protection 1987). The effective dose in adults (70 kg) resulting from 740 MBq of intravenously injected 99mTc-pertechnetate for angioscintigraphy is approximately 6.3 mSv. The absorbed radiation dose to the heart resulting from an intravenous injection of 740 MBq of 99mTc-pertechnetate corresponds to 17.0 mGy. The absorbed radiation dose to the kidneys is corresponding to 7.4 mGy.
Storage and Stability Storage. Sodium pertechnetate shielding.
99m
Tc injection is stored at room temperature with
Stability. Sodium pertechnetate 99mTc injection may be used up to 6 h after elution if the generator had been eluted within 24 h.
References Ahlgren L, Ivarsson S, Johansson L, Mattsson S, Nosslin B (1985) Excretion of radionuclides in human breast milk after administration of radiopharmaceuticals. J Nucl Med 26:1085±1090 Ancri D, Lonchampt M, Basset J (1977) The effect of tin on the tissue distribution of Tc-99m sodium pertechnetate. Radiology 124:445±450 Andros G, Harper PV, Lathrop KA, McCardle RJ (1965) Pertechnetate-99m localization in man with application to thyroid scanning and the study of thyroid physiology. J Clin Endocrinol Metab 25:1067±1076 Callahan RJ, Froelich JW, McKusick KA, Leppo J, Strauss WH (1982) A modified method for the in vivo labeling of red blood cells with Tc-99m: concise communication. J Nucl Med 23:315± 318 Council of Europe (2005 a) Sodium pertechnetate Tc-99m injection (fission), monograph 124. European pharmacopeia. Council of Europe, Maisonneuve, Sainte-Ruffine Council of Europe (2005 b) Sodium pertechnetate Tc-99m injection, monograph 283. European pharmacopeia. Council of Europe, Maisonneuve, Sainte-Ruffine Council of Europe (2004) Preparations for parenteral use, monograph 520. European pharmacopeia. Council of Europe, Maisonneuve, Sainte-Ruffine Dayton DA, Maher FT, Elveback LR (1969) Renal clearance of technetium (99mTc) as pertechnetate. Mayo Clin Proc 44:549±551 Hammermaier A, Reich E, Bægl W (1986) Chemical, radiochemical, and radionuclidic purity of eluates from different commercial fission 99Mo/99mTc-generators. Eur J Nucl Med 12:41±46 Harper PV, Beck R, Charleston D, Lathrop KA (1964) Optimization of scanning method using 99m Tc. Nucleonics 22:50±54 Harper PV, Lathrop KA, Gottschalk A (1966) Pharmacodynamics of some technetium-99m preparations. In: Andrews GA, Knisely RM, Wagner HN Jr (eds) Radioactive pharmaceuticals. AEC Symposium Series Conf 651111 1966, pp 335±357 Hays MT (1973) 99mTc-pertechnetate transport in man: absorption after subcutaneous and oral administration; secretion into saliva and gastric juice. J Nucl Med 14:331±335 Hays MT, Berman M (1977) Pertechnetate distribution in man after intravenous infusion: a compartmental model. J Nucl Med 18:898±904
179
180
12.1
99m
Tc-Pertechnetate
Hladik III WB, Ponto JA, Lentle BC, Laven DL (1987) Iatrogenic alterations in the biodistribution of radiotracers as a result of drug therapy: reported instances. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 189±219 International Commission on Radiological Protection (1987 a) Pertechnetate. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol. 18, no. 1±4. Pergamon, Oxford, pp 197±200 International Commission on Radiological Protection (1987 b) Technetium-labelled erythrocytes. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol. 18, no. 1±4. Pergamon, Oxford, pp 209±210 Jhingram SG, Johnson PC (1973) Radionuclide angiography in the diagnosis of cerebrovascular disease. J Nucl Med 14:265±268 Johannsen B, Narasimhan DVS eds (1992) Preparation of kits for 99mTc-radiopharmaceuticals. International Atomic Energy Agency: IAEA-TECDOC-649 Kusic Z, Becker DV, Saenger EL, Paras P, Gartside P, Wessler T, Spaventi S (1990) Comparison of technetium-99m and iodine-123 imaging of thyroid nodules: correlation with pathological findings. J Nucl Med 31:393±399 Lin SM, Winchell HS (1972) A ªkitº method for the preparation of a technetium-tin(II) colloid and a study of its properties. J Nucl Med 13:58±65 Lin SM, Winchell HS, Shipley BA (1971) Use of Fe(II) or Sn(II) alone for technetium labelling of albumin. J Nucl Med 12:204±211 Loberg MD (1979) Radiotracer distribution by active transport: the implications of nonlinear kinetics. In: Colombetti LG (ed) Principles of radiopharmacology, vol. III. CRC Press, Boca Raton, pp 43±59 McAfee JG, Fueger GF, Stern HS, Wagner Jr, HN, Migita T (1964) 99mTc-pertechnetate for brain scanning. J Nucl Med 5:811±827 Montelibano EB, Ford DR, Sayle BA (1979) Altered Tc-99m pertechnetate distribution in a thyroid scan after Tc-99m pyrophosphate administration. Clin Nucl Med 4:277±278 Oldendorf WH, Sisson WB, Iisaka Y (1970) Compartmental redistribution of 99mTc-pertechnetate in the presence of perchlorate ion and its relation to plasma protein binding. J Nucl Med 11:85±88 Porter WC, Dees SM, Freitas JE, Dworkin HJ (1983) Acid-citrate-dextrose compared with heparin in the preparation of in vivo/in vitro technetium-99m red blood cells. J Nucl Med 24:383±387 Prince JR, Bancroft S, Dukstein WG (1980) Pharmacokinetics of pertechnetate administered after pretreatment with 400 mg of potassium perchlorate: concise communication. J Nucl Med 21:763±766 Quinn JL (1965) 99mTc-pertechnetate for brain scanning. Radiology 84:354±355 Steigman J, Eckelman WC (1992) The chemistry of technetium in medicine. Nuclear Science Series, NAS-NS-3204 National Academy Press, Washington, D.C. Steigman J, Richards P (1974) Chemistry of technetium 99m. Sem Nucl Med 4:269±279 Steigman J, Meinken G, Richards P (1975) The reduction of pertechnetate-99 by stannous chloride±I. The stoichiometry of the reaction in HCl, in a citrate buffer and in a DTPA buffer. Int J Appl Radiat Isot 26:601±609 United States Pharmacopeial Convention (2005) Official Monographs: USP 28, technetium Tc-99m pertechnetate injection (sodium). United States Pharmacopeia (USP) 28±national formulary (NF) 23, p 1861 Welch MJ, Adatepe M, Potchen EJ (1969) An analysis of technetium (99mTcO±4) kinetics: the effect of perchlorate and iodide pretreatment. Int J Appl Radiat Isot 20:437±445 Wolff J, Maurey JR (1962) Thyroid iodide transport. III. Comparison of iodide with anions of periodic group VIIA. Biochim Biophys Acta 57:422±426
Chapter 12 Monographs of
12.2
99m
Tc Pharmaceuticals
99m
12.2.1
Tc-Labeled Human Serum Albumin
99m
Tc-Albumin (HSA)
I. Zolle and Gy. Jnoki Chemical name Human serum albumin (HSA) Technetium
99m
Tc albumin injection (Ph. Eur.)
Technetium Tc 99m albumin injection (USP) 99m
Tc-HSA
Kit components
Commercial products
Human serum albumin
10 mg
Albumoscint
Nordion
Stannous chloride dihydrate
0.02 mg
TechneScan HSA
Mallinckrodt/Tyco
VasculoCis (TCK-2)
CIS Bio
Sodium chloride q.s.
Preparation Commercial kits contain the freeze-dried, sterile formulation in a multidose vial, sealed under a nitrogen atmosphere. The lyophilized preparation is readily soluble in 99mTcpertechnetate injection and in saline. For labeling, the vial is placed into a leadshielded container. Aseptically sterile 99mTc-pertechnetate should be injected into the vial in a volume of 1±8 ml, with an activity up to 2.22 GBq (60 mCi). Before removing the syringe, 2±5 ml of gas should be withdrawn from the space above the solution to normalize the pressure inside the vial. The shielded vial should be agitated gently to dissolve the lyophilized material. The reaction should proceed at room temperature for about 20 min, with occasional agitation. 99m Tc-human serum albumin (HSA) is a clear, pale yellow solution for intravenous injection. The pH value is 2.5±3.5 (2.0±6.5, European Pharmacopeia).
Description of the Kit 99m Tc-labeled albumin is a product derived from HSA, which is a natural constituent of blood. HSA is isolated from donor blood and complies with the purity standards stated in the European Pharmacopeia (monographs 255 and 853) (Council of Europe 2004 a, b) in accordance with EU and WHO requirements for biological substances (Council of Europe 1982; World Health Organization 1994). Several methods for labeling HSA with technetium-99m in the reduced state (Steigman et al. 1975) have been described. Originally, ferric ion and ascorbic acid were used as a reducing system; labeling of HSA was performed at acidic pH (Stern et al. 1965; Persson and Liden 1969). Adjustment of the pH to 7.8 was essential in order to produce
181
182
12.2
99m
Tc-Labeled Human Serum Albumin
ferrous ion, the active principle for the reduction of Tc(VII)-pertechnetate (Zolle et al. 1973). An alternate approach used reduction of pertechnetate with concentrated HCl to produce Tc(V) in the dry state and subsequent addition of albumin for labeling at acidic pH (Williams and Deegan 1971). Additional insight into the labeling mechanism was obtained by the electrolytic reduction of pertechnetate using a zirconium crucible as the anode and a platinum wire as the cathode (Benjamin 1969; Benjamin et al. 1970). Zirconium as the anode was eventually replaced by tin (Narasimhan and Mani 1975). Anodic dissolution of Zr resp. Sn ions was made responsible for the reduction of pertechnetate and labeling of HSA at acidic pH. A sterile electrolytic kit procedure was introduced for the preparation of 99mTc-HSA by Dworkin and Gutkowski (1971). Further studies have demonstrated that high labeling yields were obtained by reduction with either Fe(II) or Sn(II) alone (Lin et al. 1971). The advantages of using stannous ion in the production of 99mTc-pharmaceuticals had been demonstrated by the one-step kit preparation of 99mTc-HSA (Eckelman et al. 1971). Freeze-drying of the nonradioactive components has considerably enhanced the stability of kits containing stannous ion (Deutsch and Redmond 1972).
Clinical Applications Intravenous injection: Cardiac blood pool imaging (static) First-pass ventriculography Gated equilibrium ventriculography Regional circulatory imaging Angiocardiography by first-pass imaging of right ventricular (RV) and left ventricular (LV) function is performed in patients with coronary artery disease. A bolus of 99mTcHSA or 99mTc-red blood cells (RBC) is injected intravenously in a small volume (Berger et al. 1979; Philippe et al. 1988). Gated radionuclide ventriculography or equilibrium (gated) radionuclide angiocardiography is performed to evaluate LV function after the radiotracer has become distributed throughout the vascular space (Strauss et al. 1971). Time of Examination. Immediately or shortly after intravenous injection, depending on the type of examination. Recommended Activities for Indications Blood pool imaging: 111±185 MBq (3±5 mCi) Angiocardiography: 370±740 MBq (10±20 mCi) as a bolus of 1±2 ml Gated ventriculography: 185±925 MBq (5±25 mCi) (or 99mTc-RBC) Circulation and blood flow: 18.5±185 MBq (0.5±5 mCi)
Additional Information 99m
Tc-HSA is administered by intravenous injection, intrathecal application is contraindicated. 99mTc-HSA has originally been used to image the placenta; however, this indi-
Chapter 12 Monographs of
cation is no longer accepted. The preparation of individuals hypersensitive to protein.
99m
99m
Tc Pharmaceuticals
Tc-HSA must not be injected into
Quality Control Radiochemical Purity. The European Pharmacopeia requires thin-layer chromatography (TLC) (distance 10±15 cm) for the identification of impurities using methylethylketone (MEK) as solvent. The radioactivity corresponding to 99mTc-HSA must not be less than 95% (Council of Europe 2005). Here, a similar procedure was used for analysis. A sample of approximately 1,000 counts/s is applied to silica gel fiberglass sheets and developed in acetone. Parallel to the labeled product, sodium 99mTc-pertechnetate is also analyzed. After development, the dried strips are cut into 1-cm pieces and measured in an NK-350 type scintillation well counter coupled with an automatic sample sorter. 99mTc-HSA remained at the start (Rf = 0.0), 99mTc-pertechnetate moved with the solvent front (Rf = 0.9±1.0). Thin-layer chromatography Stationary phase: Solvent: Developing time:
Gelman ITLC-SG (fiberglass), 2 ´ 9.5 cm Acetone 5 min
Rf values:
99m
Tc-HSA: 0.0±0.1 Tc reduced, colloidal: 0.0±0.1 Tc-Na-pertechnetate: 0.9±1.0 (< 5%)
99m
99m
A quick test for determination of unbound 99mTc-pertechnetate in labeled albumin preparations has been described using precipitation with trichloroacetic acid (TCA) and separation by membrane filtration. Free 99mTc-pertechnetate is efficiently separated from 99mTc-HSA (Lamson et al. 1974). 99mTc-HSA shows high in vitro stability (Benjamin 1969; Stern et al. 1965).
Pharmacokinetic Data Following intravenous injection, 99mTc-HSA is distributed homogenously in the vascular compartment. It does not concentrate in the thyroid, salivary, and gastric glands. In pregnant women receiving a placental scan, 50±75% of the radioactivity was measured in the blood 30 min after injection. The elimination from blood has been described by two half-times, namely 6 h and 3 days (McAfee et al. 1964; Stern et al. 1966). A comparison with 131I-albumin (131I-IHSA) in experimental animals showed that 99m Tc-HSA parallels the disappearance of 131I-albumin, being eliminated slightly faster. The tissue distribution in pregnant rabbits was also similar, showing slightly lower blood levels and a much lower concentration within the fetus. 99mTc-HSA accumulates in the kidneys, which showed the highest tissue concentration. Though at low levels, an increase of radioactivity was seen also in the stomach and gut (McAfee et al. 1964; Stern et al. 1966).
183
184
12.2
99m
Tc-Labeled Human Serum Albumin
In another extensive study (184 samples of maternal plasma and 98 samples of fetal plasma), the disappearance curve indicated an initial rapid decrease with a half-time of 2 h and a slow elimination corresponding to a half-time of 35 h. Initial plasma clearance was 16% in the first hour and 51% in 6 h, the incremental loss being 38% per day. The major loss from the albumin pool resulted from urinary excretion (32% in the first 24 h). Fecal excretion was low, with a maximum of 5.8% in 48 h. Free pertechnetate in maternal plasma (17 samples) was 2±21.2%, with a mean value of 13.6% (Herbert et al. 1969). Transplacental passage of activity was evident a few minutes after maternal injection; after 2.5 h, fetal plasma activity was in equilibrium with maternal plasma, showing 4.3% of the maternal plasma concentration, totally as free 99mTc-pertechnetate. However, the total plasma content in the fetus never exceeded 0.15% of the maternal administered activity. Urine immediately obtained after birth showed high concentrations of free 99mTc-pertechnetate. Passage of 99mTc-HSA across the placenta is minimal (Herbert et al. 1969). The fetal plasma equilibrium value of 4.3% of maternal plasma concentration was approximately twice that of IHSA reported by Hibbard and Herbert (1960); also, accumulation in the liquor was high (no liquor activity was detected with IHSA). 99m Tc-HSA was labeled by the method of Stern et al. (1965). Preparations showed high in vitro stability and contained virtually no free radionuclide when injected. Yet, no explanation has been given for the rapid liberation of technetium-99m from albumin after injection reflected in the rapid initial plasma clearance, the excretion pattern, and the evidence of fetal uptake of pertechnetate. The results of clinical studies performed by McAfee et al. (1964) and by Herbert et al. (1969) are well documented; they are, however, at variance with respect to the excretion of activity in urine and uptake in the fetus. McAfee et al. (1964) recovered less than 0.5% of the injected radioactivity in urine or feces, and 0.4% of the maternal radioactivity in two infants delivered approximately 1 and 4 h after intravenous injection to the mother. Evidence that 99mTc-HSA prepared by electrolytic kit labeling shows high in vivo stability has been provided by measuring the whole-blood disappearance in mice over a period of 90 min (Dworkin and Gutkowski 1971) and in patients for 1 h (Callahan et al. 1976).
Radiation Dose In analogy with iodine-labeled albumin, absorbed dose calculations are based on the elimination of radioactivity from blood by three half-times, namely 6.8 h (0.40), 1.29 days (0.22), and 19.4 days (0.38, Takeda and Reeve 1963). Uniform distribution of 99m Tc-HSA outside the blood pool and rapid renal excretion of the released radionuclide is assumed (International Commission on Radiological Protection 1987). The effective (whole body) dose equivalent for 99mTc-labeled albumin is 0.0079 mSv/ MBq (International Commission on Radiological Protection 1987). The effective dose in adults (70 kg) resulting from 740 MBq (20 mCi) of intravenously injected 99mTc-HSA for angioscintigraphy is approximately 5.8 mSv. Blood pool imaging with 185 MBq (5 mCi) of 99mTc-HSA is delivering 1.5 mSv.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
The absorbed radiation dose to the heart resulting from an intravenous injection of 740 MBq of 99mTc-HSA corresponds to 14.8 mGy, and to the kidneys, 6.0 mGy. The absorbed radiation dose per unit activity (GBq) of administered 99mTc-HSA is shown for selected organs in adults (70 kg) in Table 12.2.1.1. Calculations are based on a biological half-time of 6.8 h for the elimination from blood and whole body (expressed as mGy/GBq and rad/mCi). Table 12.2.1.1.
99m
Tc-human serum albumin (HSA)-Absorbed organ dose
Organs
mGy/GBq
rad/mCi
Adrenals Heart Kidney Liver Spleen
8.3 20.0 8.1 7.3 14.0
0.022 0.054 0.022 0.019 0.038
Storage and Stability Storage. Kits should be stored at 2±8 8C. in the refrigerator. Stability.
99m
99m
Tc-HSA injection solution should be kept
Tc-HSA injection solution should be used within 6 h after labeling.
References Benjamin PP (1969) A rapid and efficient method of preparing 99mTc-human serum albumin: its clinical applications. Int J Appl Radiat Isot 20:187±194 Benjamin PP, Rejali A, Friedell H (1970) Electrolytic complexation of 99mTc at constant current: its application in nuclear medicine. J Nucl Med 11:147±154 Berger HJ, Matthay RA, Pytlik L, Gottschalk A, Zaret BL (1979) First-pass radionuclide assessment of right and left ventricular performance in patients with cardiac and pulmonary disease. Semin Nucl Med 9:275±295 Callahan RJ, McKusick KA, Lamson III M, Castronovo FP, Potsaid MS (1976) Technetium-99m-human serum albumin: Evaluation of a commercially produced kit. J Nucl Med 17:47±49 Council of Europe (1992) Guide for the preparation, use and quality assurance of blood components. Council of Europe, Strasbourg Council of Europe (2004 a) Human albumin injection, monograph 255. European pharmacopeia. Council of Europe, Maisonneuve, Sainte-Ruffine Council of Europe (2004 b) Human plasma for separation, monograph 853. European pharmacopeia. Council of Europe, Maisonneuve, Sainte-Ruffine Council of Europe (2005) Technetium 99mTc albumin injection. European pharmacopeia 5.0, monograph 640. Council of Europe, Maisonneuve, Sainte-Ruffine Deutsch ME, Redmond ML (1972) Unitary freeze-dried kits for preparation of technetium-labeled human serum albumin. J Nucl Med 13(Abstr):426±427 Dworkin HJ, Gutkowski RF (1971) Rapid closed system production of 99mTc-albumin using electrolysis. J Nucl Med 12:562±565 Eckelman WC, Meinken G, Richards P (1971) 99mTc-Human serum albumin. J Nucl Med 12:707± 710 Herbert RJT, Hibbard BM, Sheppard MA (1969) Metabolic behaviour and radiation dosimetry of 99m Tc-albumin in pregnancy. J Nucl Med 10:224±232
185
186
12.2
99m
Tc-Labeled Human Serum Albumin
Hibbard BM, Herbert RJT (1960) Fetal radiation dose following administration of radio-iodinated albumin. Clin Sci 19:337±344 International Commission on Radiological Protection (1987) Technetium-labelled albumin (HSA). In: Annals of the ICRP. Radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, p 173 Lamson III M, Callahan RJ, Castronovo FP, McKusick KA, Potsaid MS (1974) A rapid index of free activity in preparations of 99mTc-albumin. J Nucl Med 15:1061±1062 Lin SM, Winchell HS, Shipley BA (1971) Use of Fe(II) or Sn(II) alone for technetium labelling of albumin. J Nucl Med 12:204±211 McAfee JG, Fueger GF, Baggish MS, Holzman GB, Zolle I (1964) 99mTc labeled serum albumin for scintillation scanning of the placenta. J Nucl Med 5:936±946 Narasimhan DVS, Mani RS (1975) Electrolytic preparation of 99mTc-human serum albumin using tin electrodes. Radiochim Radioanal Lett 20:307±316 Persson RBR, Liden K (1969) 99mTc-labelled human serum albumin: a study of the labelling procedure. Int J Appl Radiat Isot 20:241±248 Philippe L, Mena I, Sarcourt J, French WJ (1988) Evaluation of valvular regurgitation by factor analysis of first-pass angiography. J Nucl Med 29:159±167 Steigman J, Meinken G, Richards P (1975) The reduction of pertechnetate-99 by stannous chloride I. The stoichiometry of the reaction in HCl, in a citrate buffer and in a DTPA buffer. Int J Appl Radiat Isot 26:601±609 Stern HS, Zolle I, McAfee JG (1965) Preparation of 99mTc-labelled serum albumin. Int J Appl Radiat Isot l6:283±288 Stern HS, McAfee JG, Zolle I (1966) Technetium-99m±albumin. In: Andrews GA, Knisely RM, Wagner HN Jr (eds) Radioactive pharmaceuticals. AEC symposium series no. 6 (CONF651111), Oak Ridge, Tenn., pp 359±382 Strauss HW, Zaret BL, Hurley PJ, Natarajan TK, Pitt P (1971) A scintiphotographic method for measuring left ventricular ejection fraction in man without cardiac catheterization. Am J Cardiol 28:575±580 Takeda Y, Reeve EB (1963) Studies of the metabolism and distribution of albumin with autologous 131 I-albumin in healthy men. J Lab Clin Med 61:183202 United States Pharmacopeial Convention (2005) Official Monographs: Technetium Tc 99m albumin injection. United States Pharmacopeia (USP) 28±national formulary (NF) 23, p 1849 Williams MJ, Deegan T (1971) The process involved in the binding of technetium-99m to human serum albumin. Int J Appl Radiat Isot 22:767±774 World Health Organization (1994) Requirements for the collection, processing and quality control of blood, blood components and plasma derivatives, requirements for biological substances No. 27, WHO, Technical Report Series No. 840 Zolle I, Oniciu L, Hæfer R (1973) Contribution to the study of the mechanism of labelling human serum albumin (HSA) with Technetium-99m. Int J Appl Radiat Isot 24:621±626
Chapter 12 Monographs of
12.2.2
99m
Tc Pharmaceuticals
99m
Tc-Albumin Macroaggregates (MAA) (Size Range: 10±50 lm)
I. Zolle and Gy. Jnoki Chemical name Macroaggregated human serum albumin (MAA) Technetium 99m Macrosalb injection (Ph. Eur.) 99m
Tc-MAA Albumin Macroaggregates (Small square 50 ´ 50 lm, 150-fold)
Kit components
Commercial products
Macroaggregated albumin 0.5±2 mg
TechneScan MAA
Mallinckrodt/Tyco
Human albumin (HSA)
0.5 mg
MAAScint
Nordion
Stannous chloride (Dihydrate)
1.2±2.0 mg
PulmoCis (TCK-8)
CIS Bio
Macrotec Sorin
GE Healthcare
MAASol Sorin
GE Healthcare
Preparation Commercial kits contain the lyophilized, sterile components in a multidose vial, sealed under a nitrogen atmosphere. Labeling is carried out by adding aseptically a volume of 2±10 ml of sterile 99mTc-pertechnetate to the vial with an activity up to 3.7 GBq. The manufacturer's instructions should be followed. The lyophilized material will dissolve by agitating the reaction vial. The reaction should be allowed to proceed for 5±20 min, with occasional agitation. 99mTc-macroaggregated albumin (MAA) is a pale-white suspension ready for intravenous injection. The pH of the suspension is 3.5±7.5.
Description of the Kit Macroaggregates are obtained by aggregation of human serum albumin (HSA). HSA is isolated from donor blood and complies with the purity standards stated in the European Pharmacopeia, monographs 255 and 853) (Council of Europe 2004 a, b) in accordance with EU and WHO requirements for biological substances (Council of Europe 1992; World Health Organization 1994). Aggregation of albumin is carried out at acidic pH under controlled conditions, yielding macroaggregates with a particle size distribution between 10 and 90 lm. Larger aggregates are separated by filtration of the crude product. Typically, kits contain a
187
188
12.2
99m
Tc-Labeled Human Serum Albumin
suspension of MAA with a size distribution of 10±50 lm. Generally, 2 mg of macroaggregates correspond to 1.5±2 million albumin particles. Lactose, glucose (anhydrous), HSA, succinic acid, sodium acetate, sodium phosphate, dibasic sodium phytate (anhydrous), as well as Tween-80 or PVP-40 may serve as stabilizers. The kit contains no preservatives. The first suspensions of radioalbumin were introduced for photoscanning the liver, spleen, lung, and other organs, because they contained particles in the colloidal range (£ 1 lm) and between 10 and 20 lm (Taplin et al. 1964 a, b). At the time, solutions of iodinated albumin (0.1% radioalbumin, pH 5.5) with a specific activity of 1 mCi of 131I/mg of HSA) had been provided by E. R. Squibb & Sons for investigative purposes, and were heat-aggregated in-house for 20 min, at different temperatures in a water bath (60±80 8C). At Johns Hopkins, these preparations (10±100 lm) were evaluated in dogs in which pulmonary embolism had been produced experimentally, extending lung perfusion scanning to the first human studies with 131I-MAA (Wagner et al. 1964 a, b). In the early seventies, one-step kit preparations with technetium-99m became available and have contributed to the worldwide application of 99mTc-MAA (Chandra et al. 1973; Monroe et al. 1974; Robbins et al. 1976; Subramanian et al. 1972; Taplin and MacDonald 1971).
Clinical Applications Intravenous injection: Lung perfusion scintigraphy Radionuclide venography Lung perfusion imaging with labeled, biodegradable particles has become an important diagnostic tool for the diagnosis of regional perfusion defects observed in patients with pulmonary disease (i.e., emphysema, chronic obstructive disease, pulmonary hypertension, fibrosis, acute arterial obstruction) (Bell and Simon 1976; Saenger et al. 1985; Tow et al. 1966). The mechanism of lung retention of particles like MAA is known as capillary blockade. Even though a perfusion scan will localize an obstructed pulmonary artery, accurate diagnosis of pulmonary embolism requires an additional ventilation study with a radioactive gas or aerosol (Agnew 1991; Gottschalk et al. 1993 a, b; Taplin and Chopra 1978; Tow and Wagner 1967; Wagner 1995; Wagner et al. 1968). 99m Tc-MAA has also been used for the evaluation of deep vein thrombosis by venous blood flow studies (Dibos 1995; Vlahos et al. 1976). In order to visualize the deep venous system, a special technique is used for injection into veins on the dorsum of each foot. Time of Examination · Lung perfusion scintigraphy: immediately after intravenous injection · Scintigraphy of the lower extremities: shortly after bilateral intravenous injection Recommended Activities for Indications · Lung scintigraphy (adults): 37±185 MBq (1±5 mCi) · Scintigraphy of the lower extremities: 130±150 MBq (3.5±4.0 mCi). The lung scanning dose. The number of aggregates to be administered for a lung scan lies between 250,000 and 700,000. The United States Pharmacopeia (USP) limits the pro-
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
tein concentration to 1 mg of MAA per 37 MBq (1 mCi) of Tc-99m at the time of administration (United States Pharmacopeia Convention 2000). The number of macroaggregates in 1 mg has been calculated as approximately 700,000 particles, which is the upper limit for intravenous injection in adults. A sufficient number of particles need to be administered to avoid nonuniform spatial distribution of radioactivity in lung regions (Heck and Duley 1974). Calculation of safety factors. Clinical safety factors for particulate injections are derived from lethal dose (LD50) values or the minimum lethal dose (MLD) expressed in units of weight (mg/kg body weight [BW]) or as the number of particles per gram of BW. Accordingly, the amount of particles injected is given in milligrams or as the number of particles. BW is based on 70 kg (average adult). Safety factor
SF
LD50 or MLD
mg=kg 70
kg BW Injected dose
mg or number of particles
Based on SF derived from toxicity studies, the minimum amount of MAA for a lung scan in adults (70 kg) has been derived as 10 lg/kg BW, resulting in a lung scanning dose (0.7 mg) at least a 1,000 times below the minimum toxic dose in dogs (20 mg/kg) (Taplin and MacDonald 1971). If 1 mg of MAA is injected, an SF of 1,400 would apply. This safety margin also applies to an intravenous dose of 700,000 aggregates. Pediatric Dose. The amount of radioactivity for infants and children administered for lung scintigraphy is based on body weight, using the scaling factors given in Appendix 1 (Table A1.2). The number of macroaggregates in 1 ml of the injection solution should be considered. Not more than 165,000 particles should be injected in children up to 1 year of age, and not more than 50,000 aggregates in newborns (Davis and Taube 1979; Heyman 1979).
Additional Information Macroaggregates of albumin must not be injected in patients with a history of hypersensitivity to human albumin. Careful consideration should be given to limiting the number of aggregates injected when studying patients with known severe pulmonary hypertension (Vincent et al. 1968). Also, in patients with right-to-left cardiac shunts, the number of aggregated albumin particles administered for a lung scan should be reduced to the minimum, because shunted macroaggregates are distributed throughout the entire systemic circulation and may cause microembolism in the brain and kidneys (Taplin and MacDonald 1971). 99m Tc-MAA is injected intravenously with the patient in supine position. Prior to injection, the syringe should be inverted repeatedly to resuspend sedimented macroaggregates; they should be injected slowly over a period of at least 30 s to normalize different phases of the respiratory cycle (Wagner 1995). Aspiration of blood must be avoided; if blood is drawn into the syringe, formation of larger aggregates with coagulated blood occurs. The syringe should not be back flushed.
189
190
12.2
99m
Tc-Labeled Human Serum Albumin
99m Tc-MAA should not be injected through a lying catheter (butterfly) because of the occasional observation of ªhot spotsº in the lung.
Quality Control Radiochemical Purity. The European Pharmacopeia (Council of Europe 2005) requires membrane filtration (3 lm) for the determination of radiochemical purity. Unbound radioactivity is in the filtrate; not less than 90% of the total radioactivity is measured on the filter. The USP permits centrifugation of a sample obtained from a well mixed injection solution. Less than 10% of the total radioactivity is measured in the supernatant. Paper chromatography (USP) is recommended for the identification of impurities, using 70% methanol as solvent. Free 99mTc-sodium pertechnetate is measured at Rf = 0.6, and 99mTc-MAA is identified at the origin. The radiochemical purity of 99mTcMAA should not be less than 90%. Paper chromatography (USP) Stationary phase: Solvent:
Whatman No. 1 paper Methanol : water, 70 : 30 (v/v)
Rf values:
99m
Tc reduced, hydrolized: Tc-MAA: 99m Tc-Na-pertechnetate: 99m
0.0±0.1 0.0±0.1 (> 90%) 0.6±0.7
Thin-layer chromatography (recommended by the manufacturer) Stationary phase: Solvent:
Gelman ITLC-SG (fiberglass), 2 ´ 9.5 cm Acetone (resp. methylethylketone [MEK])
Rf values:
99m
Tc reduced, hydrolized: Tc-MAA: 99m Tc-Na-pertechnetate: 99m
0.0±0.1 0.0±0.1 0.9±1.0
Thin-layer chromatography offers the advantage of rapid development (5±10 min). Quantification of labeled components. Each chromatogram is measured (TLC linear analyzer or gamma counter), and the regional radioactivities are expressed as a percentage of the total recovered counts: 99m
Tc-MAA
% 100
F
where F (%) = 99mTc-Na-pertechnetate (free).
Chapter 12 Monographs of
Results of
99m
99m
Tc Pharmaceuticals
Tc-MAA analysis (12 samples)
Labeling and stability
20 min (%)
4 h (%)
Paper chromatography 99m Tc-macroaggregates 99m Tc-Na-pertechnetate
98.8Ô0.06 1.2Ô0.05
99.2Ô0.04 0.8Ô0.06
Thin-layer chromatography 99m Tc-macroaggregates 99m Tc-pertechnetate
99.4Ô0.01 0.6Ô0.02
99.6Ô0.01 0.4Ô0.01
Particle Size Distribution. The method described in the European Pharmacopeia is based on the microscopic examination of 5,000 albumin aggregates, using a suitable counting chamber such as a hemocytometer. Macroaggregates show a size distribution of diameters between 10 and 90 lm. Typically, 90% of a suspension is within 10±50 microns. Less than ten aggregates are bigger than 75 lm; none is larger than 100 lm. The number of macroaggregates in 1 ml of the injection solution should also be determined.
Pharmacokinetic Data Following intravenous injection, more than 90% of the technetium-99m MAA is extracted during the first pass and retained in lung capillaries (8.2 Ô 1.5 lm) and arterioles (25 Ô 10 lm) (Taplin and MacDonald 1971). Organ selectivity is directly related to particle size. Albumin aggregates smaller than 8 lm pass the pulmonary capillary bed and are taken up in the reticuloendothelial system. With a particle diameter above 15 lm, aggregates are retained in the lung capillaries by a purely mechanical process. Distribution of aggregated albumin in the lung is a function of regional pulmonary blood flow (Wagner et al. 1964 a). Macroaggregates are sufficiently fragile for the capillary microocclusion to be temporary. Erosion and fragmentation reduce the particle size, facilitating removal of aggregates from the lung (Taplin and MacDonald 1971). Subsequently, the fragments are accumulated in the liver by phagocytosis (Chandra et al. 1973; Robbins et al. 1976). The elimination of radioactivity from the lung is described by half-times between 4 and 6 h (Taplin and MacDonald 1971). Experimental data indicate an initial fast component, which has been interpreted as rapid release of unbound 99mTc activity (Malone et al. 1983). Accumulation in the liver is assumed to amount to 25%, with an uptake half-time of 6 h and an elimination half-time of 5 days (International Commission on Radiological Protection 1987); considerable uptake in the liver has been reported (Chandra et al. 1973; Robbins et al. 1976). Excretion of released pertechnetate in the urine is reported as 40 Ô 14% in 24 h, and an additional 9.0 Ô 3.8% up to 48 h. Intestinal activity has been shown to increase slowly up to 24 h (Malone et al. 1983).
191
192
12.2
99m
Tc-Labeled Human Serum Albumin
Radiation Dose Lung, liver, and the bladder wall are the most exposed organs. The effective (whole body) dose equivalent is 0.012 mSv/MBq (International Commission on Radiological Protection 1987). Elimination from the lung is assumed with half-times of 6 h (0.85) and 3 days (0.15). The liver takes up a fraction of 0.25, with an uptake half-time of 6 h and an elimination half-time of 5 days. Radionuclide released from the lung is primarily excreted by the kidneys (Malone et al. 1983). The effective (whole body) dose in adults (70 kg) resulting from an intravenous injection of 185 MBq of 99mTc-MAA for lung scintigraphy is approximately 2.2 mSv. The absorbed radiation dose to the lung resulting from an intravenous injection of 185 MBq of 99mTc-MAA for a lung scan corresponds to 12.4 mGy, and to the liver, approximately 3.0 mGy. The effective (whole body) dose resulting from bilateral venography injecting a total of approximately 185 MBq (5 mCi) of 99mTc-MAA was estimated as 1.35 mSv (Malone et al. 1983).
Storage and Stability Storage. Kits should be stored at 2±8 8C, and kept at 2±8 8C, with adequate shielding. Stability.
99m
99m
Tc-MAA injection solution should be
Tc-MAA injection solution should be used within 6 h after labeling.
References Agnew JE (1991) Characterizing lung aerosol penetration. J Aerosol Med 4:237±250 Bell WR, Simon TL (1976) A comparative analysis of pulmonary perfusion scans with pulmonary angiograms: From a national cooperative study. Am Heart J 92:700±706 Chandra R, Shannon J, Braunstein P, Durlov OL (1973) Clinical evaluation of an instant kit for preparation of 99mTc-MAA for lung scanning. J Nucl Med 14:702±705 Council of Europe (1992) Guide for the preparation, use and quality assurance of blood components. Council of Europe, Strasbourg Davis MD, Taube RA (1979) Re: toxicity and safety factors associated with lung perfusion studies with radiolabeled particles (letter to the editor). J Nucl Med 20:1099 Dibos PE (1995) Deep venous thrombosis. In: Wagner HN Jr, Szabo S, Buchanan JW (eds) Principles of nuclear medicine, 2nd edn. Saunders, Philadelphia, pp 872±880 Council of Europe (2004 a) Human albumin injection, monograph 255. European pharmacopeia. Council of Europe, Maisonneuve, Sainte-Ruffine Council of Europe (2004 b) Human plasma for separation, monograph 853. European pharmacopeia. Council of Europe, Maisonneuve, Sainte-Ruffine Council of Europe (2005) Technetium 99mTc macrosalb injection. European pharmacopeia 5.0, monograph no 296. Council of Europe, Maisonneuve, Sainte-Ruffine Gottschalk A, Juni JE, Sostman HD, Coleman RE, Thrall J, McKusick KA, Froelich JW, Alavi A (1993 a) Ventilation-perfusion scintigraphy in the PIOPED study. Part I. Data collection and tabulation. J Nucl Med 34:1109±1118 Gottschalk A, Sostman HD, Coleman RE, Juni JE, Thrall J, McKusick KA, Froelich JW, Alavi A (1993 b) Ventilation-perfusion scintigraphy in the PIOPED study. Part II. Evaluation of the scintigraphic criteria and interpretations. J Nucl Med 34:1119±1126
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Heck LL, Duley JW Jr (1974) Statistical considerations in lung imaging with Tc-99m-albumin particles. Radiology 113:675±679 Heyman S (1979) Toxicity and safety factors associated with lung perfusion studies with radiolabeled particles (letter to the editor). J Nucl Med 20:1098±1099 International Commission on Radiological Protection (1987) Technetium-labelled macroaggregated albumin. In: Annals of the ICRP. Radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol. 18, no. 1±4. Pergamon, Oxford, pp 223±224 Malone LA, Malone JF, Ennis JT (1983) Kinetics of technetium 99m-labelled macroaggregated albumin in humans. Br J Radiol 56:109±112 Monroe LA, Thompson WL, Anderton NS, Burdine JA (1974) Evaluation of an improved 99mTcstannous aggregated albumin preparation for lung scanning. J Nucl Med 15:192±194 Robbins PJ, Feller PA, Nishiyama H (1976) Evaluation and dosimetry of a 99mTc-Sn-MAA lung imaging agent in humans. Health Phys 30:173±176 Saenger EL, Buncher CR, Specker BL, McDvitt RA (1985) Determination of clinical efficacy: nuclear medicine as applied to lung scanning. J Nucl Med 26:793±806 Subramanian G, Arnold RW, Thomas FD, McAfee JG (1972) Evaluation of an instant 99mTc-labeled lung scanning agent. J Nucl Med 13(Abstr):790 Taplin GV, Chopra SK (1978) Lung perfusion-inhalation scintigraphy in obstructive airway disease and pulmonary embolism. Radiol Clin N Am 16:491±513 Taplin GV, MacDonald NS (1971) Radiochemistry of macroaggregated albumin and newer lung scanning agents. Sem Nucl Med 1:132±152 Taplin GV, Johnson DE, Dore EK, Kaplan HS (1964 a) Suspensions of radioalbumin aggregates for photoscanning the liver, spleen, lung and other organs. J Nucl Med 5:259±275 Taplin GV, Johnson DE, Dore EK, Kaplan HS (1964 b) Lung photoscans with macroaggregates of human serum radioalbumin. Health Phys 10:1219±1227 Tow DE, Wagner HN Jr (1967) Recovery of pulmonary arterial blood flow in patients with pulmonary embolism. N Engl J Med 276:1053±1059 Tow DE, Wagner HN Jr, Lopez-Majano V, Smith E, Migita T (1966) Validity of measuring regional pulmonary arterial blood flow with macroaggregates of human serum albumin. Am J Roentgenol 96:664±676 United States Pharmacopeial Convention (2005) Official Monographs: Technetium Tc 99m albumin aggregated injection. United States Pharmacopeia (USP) 28±national formulary (NF) 23, p 1850 Vincent WR, Goldberg SJ, Desilets D (1968) Fatality immediately following rapid infusion of macroaggregates of 99mTc-albumin (MAA) for lung scan. Radiology 91:1181±1184 Vlahos L, MacDonald AF, Causer DA (1976) Combination of isotope venography and lung scanning. Br J Radiol 49:840±851 Wagner HN Jr (1995) Regional ventilation and perfusion. In: Wagner HN Jr, Szabo S, Buchanan JW (eds) Principles of nuclear medicine, 2nd edn. Saunders, Philadelphia, pp 887±895 Wagner HN Jr, Sabiston DC Jr, Iio M, McAfee JG, Langan JK (1964 a) Regional pulmonary blood flow in man by radioisotope scanning. JAMA 187:601±603 Wagner HN Jr, Sabiston DC Jr, McAfee JG, Tow DE, Stern HS (1964 b) Diagnosis of massive pulmonary embolism in man by radioisotope scanning. N Engl J Med 271:377±384 Wagner HN Jr, Lopez-Majano V, Langan JK, Joshi RC (1968) Radioactive xenon in the differential diagnosis of pulmonary embolism. Radiology 91:1168±1174 World Health Organization (1994) Requirements for the collection, processing and quality control of blood, blood components and plasma derivatives, requirements for biological substances No. 27, Technical Report Series No. 840
193
194
12.2
99m
12.2.3
Tc-Labeled Human Serum Albumin 99m
Tc-Albumin Microspheres (HAM) (Size Range: 10±50 lm)
I. Zolle Chemical name Human serum albumin microspheres (HAM) HSA-microspheres Technetium (Ph. Eur.)
99m
Tc microspheres injection
99m
Tc-HSA microspheres
99m
Tc-HAM
Albumin microspheres (40 lm) (Small square 50 ´ 50 lm, 150-fold)
Kit components(1) HSA-microspheres
Kit components(2) 10.0 mg
HSA-microspheres
2.5 mg
Stannous chloride ´ 2 H2O
1.3 mg
Stannous chloride ´ 2 H2O 0.1 mg
Pluronic F68
0.25 mg
Tween-80
Sodium chloride
9.0 mg
0.6 mg
Preparation Commercial kits contain the lyophilized, sterile components including preformed albumin microspheres in a multidose vial, sealed under a nitrogen atmosphere. Labeling with 99m Tc eluate is carried out under aseptic conditions by injecting a volume of 2±10 ml of eluate corresponding to a 99mTc activity of maximal of 5.5 GBq (5±150 mCi). The reaction is allowed to proceed at room temperature for 15 min. 99mTc-human albumin microspheres (HAM) is a sterile, pyrogen-free suspension suitable for intravenous injection. The pH of the injection solution is 4.0±9.0 (European Pharmacopeia).
Description of the Kit Albumin microspheres are obtained by heat denaturation of HSA in vegetable oil (Zolle et al. 1970). HSA (25% solution) used for preparation of microspheres complies with the purity standards stated in the European Pharmacopeia (Council of Europe 2004 a, b) in accordance with EU and WHO requirements for biological substances (Council of Europe 1992; World Health Organization 1994). The size distribution of albumin particles depends mainly on the degree of dispersion of HSA in oil; generally, a size distribution between 12 and 45 lm was produced.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Fractions with distinct size ranges were obtained by sieving (Rhodes et al. 1969; Zolle et al. 1970). This permits a close estimate of the number of microspheres in 1 mg. Commercial kits may contain 10 mg of microspheres, corresponding to 800,000± 1,600,000 microspheres per vial (kit formulation 1) or 2.5 mg of microspheres, corresponding to 300,000±500,000 microspheres per vial (kit formulation 2). Typically, kits contain albumin microspheres with a size distribution between 10 and 50 lm. Tween80 or Pluronic F68 serve as surfactants to avoid aggregation of microspheres. Originally, albumin microspheres containing iron (ferric hydroxide) were used for labeling with 113mIn or 99mTc; these labeling procedures included heating in a water bath (Rhodes et al. 1969). Later on, a kit preparation of 99mTc-HAM, using iron loaded microspheres in the presence of sodium thiosulfate at acidic pH (and heating) was introduced (Bolles et al. 1973; Krejcarek et al. 1974). A comparison of different labeling techniques has been reported (Mayron and Kaplan 1975). Preformed albumin microspheres are labeled with high radiochemical yield either by using a commercial kit or by electrolytic reduction by using a tin electrode. No heating or pH adjustments are required. The specific activity of 99mTc-HAM should not be less than 185 MBq (5 mCi) per 1 million microspheres according to the European Pharmacopeia (Council of Europe 2005). 99m Tc-eluate used for labeling the preformed microspheres should be obtained from a generator by daily elution in order to minimize 99Tc carrier, and should comply with specifications stated in the European Pharmacopeia.
Clinical Applications Intravenous injection: Pulmonary perfusion scintigraphy Determination of right-to-left shunts Arterial injection: Regional perfusion in other organs 99m
Tc-albumin microspheres satisfy the requirements of particles for systemic application with the indicator fractionation technique, namely, uniform size and shape, available in desired sizes, extracted completely in a single passage through capillary beds, and metabolized within hours after injection (Rhodes et al. 1969, 1971; Wagner et al. 1968, 1969; Zolle and Kropf 1982). When injected into a systemic artery, microspheres indicate regional blood flow in that organ. Myocardial blood flow was measured in dogs (Fortuin et al. 1971; Weller et al. 1972) . 99mTc-HAM has also been used for measuring regional blood perfusion in the heart (Martin et al. 1973) and the brain in monkeys (Alm 1975). This method has been used for the measurement of the shunted blood through patent arteriovenous connections in the leg after femoral artery injection (Rhodes et al. 1969, 1973). The size and number of microspheres can be controlled, and labeling is performed with high specific activity; as a result, 99mTc-albumin microspheres of distinct particle size have been used to quantify the shunted blood flow reaching the lungs (Strauss et al. 1969; Wagner et al. 1969) and arteriovenous shunts in brain tumors (Bergmann et al. 1973). Time of Examination · Lung perfusion scintigraphy: immediately after intravenous injection · Regional organ perfusion: immediately after arterial injection
195
196
12.2
99m
Tc-Labeled Human Serum Albumin
Recommended Activities for Indications Lung scintigraphy: 75±185 MBq, (2±5 mCi) injected intravenously £ 0.010 mg microspheres/kg body weight (BW) £ 250,000 microspheres (Food and Drug Administration [FDA]) Regional organ scintigraphy: 75±111 MBq, (2±3 mCi) injected intraarterially The lung scanning dose. The number of microspheres to be administered for a lung scan lies between 100,000 and 250,000. The lung scanning dose normalized to BW is 10 lg/kg, keeping the patient dose generally below 1 mg of microspheres. The FDA has limited the number of microspheres used for lung scintigraphy to 250,000 particles. However, a sufficient number of particles need to be administered to avoid nonuniform spatial distribution of radioactivity in lung regions (Heck and Duley 1974). Calculation of safety factors. Clinical safety factors for particulate injections are derived from LD50 values or the minimum lethal dose (MLD) expressed in units of weight (mg/ kg BW) or as the number of particles per gram of BW. Accordingly, the amount of particles injected is given in mg or as the number of particles. BW is based on 70 kg (average adult). Safety factor
SF
LD50 or MLD
mg=kg 70
kg BW Injected dose
mg or number of particles
The sublethal toxicity of microspheres (15±30 lm) in the lung was determined as 20 mg/kg BW in dogs (Bolles et al. 1973). Based on a patient dose of 0.7±1 mg of microspheres (15±30 lm) for lung perfusion scintigraphy, SFs between 1,400 and 2,000 are derived. Theoretically, 1 mg of microspheres with a diameter of 20 lm contains 238,732 spheres. A sample of microspheres ranging between 12 and 29 lm in diameter actually showed 234,800±246,000 spheres in 1 mg by Coulter measurements (Zolle et al. 1970). Pediatric Dose. The amount of radioactivity for infants and children administered for lung scintigraphy is based on body weight, using the scaling factors given in Appendix 1 (Table A1.2). In addition, the number of microspheres in 1 ml of injection solution should also be considered. Only a fraction of the number of microspheres used in adults should be administered in children (Davis and Taube 1978; Heyman 1979).
Additional Information The use of 99mTc-albumin microspheres in patients with a history of hypersensitivity to human albumin is contraindicated. 99m Tc-albumin microspheres should not be injected together with other drugs or components to avoid aggregates. For intravenous injection 99mTc-HAM microspheres should be homogenously suspended to avoid in vivo aggregates. For this reason, the aspiration of blood into the syringe must be avoided.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
99m Tc-HAM should not be injected through a lying catheter (butterfly) because of the occasional observation of ªhot spotsº in the lung.
Quality Control Radiochemical Purity. 99mTc-albumin microspheres are described in the European Pharmacopeia (Council of Europe 2005). Membrane filtration (3-lm pore size) is used to determine unbound radioactivity in the filtrate. Not less than 95% of the total radioactivity is measured on the filter. An alternate method for laboratory use is centrifugation of a homogenously suspended sample of 99mTc-albumin microspheres for 2 min at 2,000 rpm and separation of the supernatant. Both test tubes are measured in a gamma counter, and the radioactivity is expressed as a percentage of the sum of recovered counts. Less than 5% of the total radioactivity is measured in the supernatant. Recommended Methods Paper chromatography is recommended by the manufacturer, using 80% methanol as solvent. Free 99mTc-sodium pertechnetate is measured at an Rf of 0.6 and 99mTc-HAM at the origin (Rf = 0.0). The radiochemical purity of 99mTc-HAM should not be less than 95%. Recommended methods for the determination of radiochemical purity Paper chromatography Stationary phase: Solvent: Developing time:
Whatman No. 1 paper strips, 2 ´ 9.5 cm Methanol : water, 80 : 20 (v/v) 10 min
Rf values:
99m
Tc-HAM: Tc-pertechnetate:
99m
0.0±0.1 (> 95%) 0.6±0.7
Thin-layer chromatography Stationary phase: Solvent: Developing time:
Gelman ITLC-SG (fiberglass), 2 ´ 9.5 cm Acetone 5 min
Rf values:
99m
Tc HAM: Tc reduced, colloidal: 99m Tc-pertechnetate: 99m
0.0±0.1 0.0±0.1 0.9±1.0 (<5%)
Quantification of labeled components. Each chromatogram is measured (TLC linear analyzer or gamma counter), and the regional radioactivities are expressed as a percentage of the total recovered counts: 99m
Tc-HAM
% 100
F
where F (%) = 99mTc-Na-pertechnetate (free).
197
198
12.2
99m
Tc-Labeled Human Serum Albumin
Results of analysis (12 samples) Results were obtained using paper chromatography and methanol-water as solvent. Labeling and stability
15 min (%)
3 h (%)
99m Tc-HSA microspheres Free 99mTc-pertechnetate
99.1 Ô 0.05 0.9 Ô 0.05
98.6 Ô 0.20 1.4 Ô 0.21
Particle Size Distribution. The method described in the European Pharmacopeia is based on the microscopic examination of 5,000 albumin microspheres, using a suitable counting chamber such as a hemocytometer. Microspheres show a homogenous distribution of diameters between 10 and 50 lm. Less than ten microspheres are bigger than 75 lm, and none is larger than 100 lm. The number of microspheres in 1 ml of the injection solution should also be determined.
Pharmacokinetic Data 99m
Tc-albumin microspheres are trapped in the first capillary bed they encounter. When injected intravenously, this is the lung (Zolle and Kropf 1982; Zolle et al. 1970). More than 95% of the injected radioactivity is extracted by the pulmonary capillaries and arterioles in a single passage and distributed in the lung according to regional pulmonary arterial blood flow. The size of the microspheres and the diameter of blood vessels affect the measurement of blood flow. Capillary sizes may vary from organ to organ, and a fraction of the blood may pass through arteriovenous shunts. Under these conditions, 99mTc-HAM bypass the pulmonary circulation when injected for lung scanning. Microspheres passing through transpulmonary shunts are distributed throughout the systemic circulation. The brain is selected for measuring the fractional radioactivity of microspheres lodged in the cerebral microcirculation (Strauss et al. 1969). 99m Tc-albumin microspheres are metabolized in the capillary lumen (Zolle and Kropf 1982; Zolle et al. 1970). Lung removal rates depend on the size and density of microspheres. Larger microspheres are removed from the lung more slowly. Microspheres with a particle diameter of 12±44 lm are extracted from blood almost completely (³ 98%); when prepared at 146 8C, HSA microspheres are eliminated from lung capillaries with a biological half-time of 7.2 h (Zolle and Kropf 1982; Zolle et al. 1970). Toxicity and Safety Factors. Hemodynamic effects caused by capillary blockade show a direct relationship between the size and number of microspheres injected (Mishkin and Brashear 1971). To avoid an overdose of microspheres, the parameters causing an increase in pulmonary arterial pressure were systematically investigated (Allen et al. 1978; Davis and Taube 1978; Harding et al. 1973; Heyman 1979). Calculations derived from microspheres with uniform size, having diameters of 20, 28, 40, and 60 lm, have indicated a similar proportion of pulmonary vessels blocked, namely 0.2±0.3%, when 1 mg of these microspheres was injected. However, when calculations were based on the same number of microspheres (i.e., 100,000), the percentage of blocked vessels increased considerably with the diameter of the microspheres (Harding et al. 1973).
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Table 12.2.3.1 Influence of particle size on safety factors expressed for total number (100,000) and total mass (mg) of particles injected Particle diameter (lm)
No. of particles per mg
Safety factors Per 105 particles injected
Per mg total mass injected
13.5 15.0 15.8 25.7 28.0 45.4 90.7
776,247 565,884 484,206 112,513 87,002 20,410 2,560
62,380 33,600 33,600 16,630 16,630 4,010 360
8,094 5,938 6,939 14,781 19,114 19,647 14,062
HSA microspheres with a size distribution between 20 and 40 lm contain approximately 90,000 microspheres per milligram. Smaller HSA microspheres with a size distribution between 15 and 20 lm contain approximately 500,000 microspheres per milligram (Table 12.2.3.1). 99m Tc-albumin microspheres (£ 1 mg) are well tolerated without complications (Rhodes 1971; Stang et al. 1975). One case of adverse reaction to 99mTc-HAM has been reported (Littenberg 1975). Hypersensitivity reactions are rare and caused mainly by agents used for suspension of 99mTc-albumin microspheres. Intracoronary injection of up to 200,000 microspheres had no significant effect upon cardiac function and does not cause myocardial damage (Weller 1975). Sublethal pulmonary toxicity. Albumin microspheres (15±30 lm) were repeatedly administered in dogs and monkeys showing transient symptoms such as diarrhea, emesis, or decreased activity with amounts of 20 mg/kg BW (Bolles et al. 1973). Single doses up to 40 mg/kg BW were tolerated in mice, rabbits, and dogs without complications (Rhodes et al. 1969). Acute pulmonary toxicity. The first signs of pulmonary toxicity are an abrupt increase in the pulmonary artery pressure and a sharp fall in the femoral artery pressure (Bolles et al. 1973). The lethal dose (LD50) of microspheres (15±30 lm) in mice is 72.2 Ô 8.3 mg/kg BW and in rats, 43.8 Ô 5.0 mg/kg BW.
Radiation Dose The lung and bladder wall are the most exposed organs. The effective (whole body) dose equivalent is 0.011 mSv/MBq (International Commission on Radiological Protection 1987). Elimination from the lung is assumed with half-times of 1.8 h (0.60) and 1.5 days (0.40). Radionuclide released from the lung is primarily excreted by the kidneys (Blau et al. 1982). The effective (whole body) dose in adults (70 kg) resulting from an intravenous injection of 185 MBq of 99mTc-HAM for lung scintigraphy is 2.0 mSv. The absorbed radiation dose to the lung resulting from an intravenous injection of 185 MBq of 99mTc-HAM is 10.7 mGy.
199
200
12.2
99m
Tc-Labeled Human Serum Albumin
Storage and Stability Storage. The lyophilized kit is stored at 2±8 8C. Stability. The
99m
Tc-HAM injection solution is stable for 6 h after preparation.
References Allen DR, Ferens JM, Cheney FW, Nelp WB (1978) Critical evaluation of acute cardiopulmonary toxicity of microspheres. J Nucl Med 19:1204±1208 Alm A (1975) Radioactively labelled microspheres in regional cerebral blood flow determinations. A study on monkeys with 15- and 35-lm spheres. Acta Physiol Scand 95:60±65 Bergmann H, Bæck F, Brenner H, Hæfer R (1973) Quantitative evaluation of arterio-venous shunts in brain tumours. In: Medical radioisotope scintigraphy 1972, vol. II, International Atomic Energy Agency, Vienna, p 487 Blau M, Wicks R, Thomas SR, Lathrop KA (1982) MIRD dose estimate report no. 10. Radiation absorbed dose from albumin microspheres labelled with technetium-99m. J Nucl Med 23:915±917 Bolles TF, Kubiatowicz DO, Evans RL, Grotenhuis IM, Nora JC (1973) Tc-99m-labelled albumin (human) microspheres (15±30 micron). Their preparation, properties and uses. In: Radiopharmaceuticals and labelled compounds, vol. 1. International Atomic Energy Agency, Vienna, p 151±167 Council of Europe (1992) Guide for the preparation, use and quality assurance of blood components. Strasbourg Council of Europe (2004 a) Human albumin injection, monograph 255. European pharmacopeia. Council of Europe, Maisonneuve, Sainte-Ruffine Council of Europe (2004 b) Human plasma for separation, monograph 853. European pharmacopeia. Council of Europe, Maisonneuve, Sainte-Ruffine Council of Europe (2005) Technetium 99mTc microspheres injection. European pharmacopeia 5.0, monograph no 570. Council of Europe, Maisonneuve, Sainte-Ruffine Davis MA, Taube RA (1978) Pulmonary perfusion imaging: acute toxicity and safety factors as a function of particle size. J Nucl Med 19:1209±1213 Fortuin NJ, Kaihara S, Becker LC, Pitt B (1971) Regional myocardial blood flow in the dog studied with radioactive microspheres. Cardiovasc Res 5:331±336 Harding LK, Horsfield K, Singhal SS, Cumming G (1973) The proportion of lung vessels blocked by albumin microspheres. J Nucl Med 14:579±581 Heck LL, Duley JW Jr (1974) Statistical considerations in lung imaging with Tc-99m-albumin particles. Radiology 113:675±679 Heyman S (1979) Toxicity and safety factors associated with lung perfusion studies with radiolabeled particles. J Nucl Med 20:1098±1099 International Commission on Radiological Protection (1987) Technetium-labelled albumin microspheres (1987) In: Annals of the ICRP, Radiation dose to patients from radiopharmaceuticals, Biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, pp 227±228 Krejcarek GE, Bradford KL, Bolles TF (1974) Instant labelling human serum albumin microspheres. J Nucl Med 15(Abstr):509 Littenberg RL (1975) Anaphylactoid reaction to human albumin microspheres. J Nucl Med 16:236± 237 Martin LG, Larose JH, Sybers RG, Tyras DH, Symbas PN (1973) Myocardial perfusion imaging with Tc-99m-albumin microspheres. Radiology 107:367±370 Mayron LW, Kaplan E (1975) A comparison of four techniques for labelling albumin microspheres with technetium-99m. Int J Nucl Med Biol 2:74±80 Mishkin FS, Brashear RE (1971) Pulmonary and systemic blood pressure responses to large doses of albumin microspheres. J Nucl Med 12:251±252 Rhodes BA (1971) Low probability of allergic reaction to albumin microspheres. J Nucl Med 12:649±650 Rhodes BA, Zolle I, Buchanan JW, Wagner HN Jr (1969) Radioactive albumin microspheres for studies of the pulmonary circulation. Radiology 92:1453±1460
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Rhodes BA, Stern HS, Buchanan JW, Zolle I, Wagner HN Jr (1971) Lung scanning with Tc-99mmicrospheres. Radiology 99:613±621 Rhodes BA, Greyson ND, Siegel ME, Giargiana FA Jr, White RI Jr, Williams GM, Wagner HN Jr (1973) The distribution of radioactive microspheres after intra-arterial injection in the legs of patients with peripheral vascular disease. Am J Roentgenol Radium Ther Nucl Med 118:820±826 Stang PC, Roelands JF, Cohen P (1975) Immunologic relationships of human serum albumin, macroaggregated albumin and albumin microspheres. In: Subramanian G, Rhodes BA, Cooper JF, Sodd VJ (eds) Radiopharmaceuticals. Society of Nuclear Medicine, New York, p 292 Strauss HW, Hurley PJ, Rhodes BA, Wagner HN Jr (1969) Quantification of right-to-left transpulmonary shunts in man. J Lab Clin Med 74:597±607 Wagner HN Jr, Stern HS, Rhodes BA, Reba RC, Hosain F, Zolle I (1968) Design and development of new radiopharmaceuticals. In: Medical radioisotope scintigraphy, vol. II. IAEA Vienna, pp 3±24 Wagner HN Jr, Rhodes BA, Sasaki Y, Ryan JP (1969) Studies of the circulation with radioactive microspheres. Invest Radiol 4:374±386 Weller DA (1975) Toxicity of particles on intracoronary injection. In: Subramanian G, Rhodes BA, Cooper JF, Sodd VJ (eds) Radiopharmaceuticals. Society of Nuclear Medicine, New York, p 370 Weller DA, Adolph RJ, Wellman HN, Carrol RG, Kim O (1972) Myocardial perfusion scintigraphy after intracoronary injection of Tc-99m-labeled human albumin microspheres. Toxicity and efficacy for detecting myocardial infarction in dogs, preliminary results in man. Circulation 46:963±975 World Health Organization (1994) Requirements for the collection, processing and quality control of blood, blood components and plasma derivatives, requirements for biological substances No. 27. WHO Technical Report Series No. 840 Zolle I, Kropf G (1982) Factors affecting the trapping and clearance of microspheres. In: Anghilieri L (ed) General processes of radiotracer localization, vol. 2. CRC Press, Boca Raton, pp 15±38 Zolle I, Rhodes BA, Wagner HN Jr (1970) Preparation of metabolizable radioactive human serum albumin microspheres for studies of the circulation. Int J Appl Rad Isot 21:155±167
12.3
99m
12.3.1
Tc-Labeled Colloids
99m
12.3.1.1
Tc-Labeled Microcolloids
99m
Tc-Tin Colloid (Size Range: 0.2±0.8 lm)
I. Zolle Chemical name
Listed trade names
Colloidal tin hydroxide
Amerscan Hepatate II
GE Healthcare (1)
Livoscint
Bristol-Myers Squibb (2)
Technetium (Ph. Eur.) 99m
99m
Tc tin colloid injection
Tc-tin colloid
Kit components(1)
Kit components(2)
Tin(II)-fluoride
0.125 mg
Tin(II)-chloride dihydrate
0.3 mg
Sodium fluoride
1.0 mg
Sodium fluoride
0.9 mg
Poloxamer 188
0.5 mg
Sodium chloride
4.5 mg
201
202
12.3
99m
Tc-Labeled Colloids
Preparation The kit contains the lyophilized, sterile ingredients in a multidose vial. Labeling with 99m Tc-pertechnetate is carried out under aseptic conditions by adding a suitable volume of sterile 99mTc eluate, up to 3.7 GBq (100 mCi) to the reaction vial. The reaction is allowed to proceed at room temperature for 20 min. 99mTc-tin colloid is a sterile, pyrogen-free, opalescent solution suitable for intravenous injection. The pH is 4.0±6.0 on pH paper.
Description of the Kit 99m
Tc-tin colloid is a hydrolysis product and easily formed at pH > 3, with the reduced technetium-99m-oxide (Lin and Winchell 1972). Poloxamer 188 is added to stabilize the colloid. No heating or pH adjustments are required. Once formed, the particle size distribution is unaffected by time. The 99mTc-tin colloid shows a particle size distribution between mainly 0.2 and 0.8 lm (Lin and Winchell 1972; Whateley and Steele 1985). Factors causing low colloid formation (low specific activity) are primarily related to pH, inadequate reaction time, or a defect of kit formulation. 99mTc eluate used for colloid preparation should be obtained from a generator by daily elution in order to minimize 99Tc carrier (Ponto et al. 1987).
Clinical Applications Intravenous injection:
Liver and spleen scintigraphy
Time of Examination · 10±15 min after the intravenous injection Recommended Activities for Indications Liver and spleen scintigraphy: 75±185 MBq (2±5 mCi), injected intravenously, slowly 200 MBq maximal activity for single-photon emission computed tomography (SPECT) 0.2 mg tin colloid/kg body weight The manufacturer's instructions should be followed. Pediatric Dose. The amount of radioactivity for infants and children administered for liver/spleen scintigraphy is based on body weight, using the scaling factors given in Appendix 1, Table A1.2. The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Additional Information 99m
Tc-tin colloid should not be injected together with other drugs or components. Diffuse pulmonary accumulation of radiocolloids may result from elevated plasma levels of aluminum in patients with antacid therapy, because the 99mTc-tin colloid coprecipitates with larger aggregates of aluminum phosphate (Ponto et al. 1987). A number of clinical conditions associated with pulmonary uptake of 99mTc-labeled colloids have been reported (Hladik et al. 1987 a). Hepatotoxic substances interfere with phagocytosis, causing transient changes, such as inhomogeneous or irregular distribution of radiocolloids in the liver/spleen or a shift of uptake from liver to spleen and/or bone marrow. Anesthetics (halothane) affect both phagocytic and catabolic reticuloendothelial system (RES) function, resulting in an increased uptake in the spleen (Hladik et al. 1987 b). The plasma expander dextran or protein deficiency may also reduce uptake of 99mTc-labeled colloids by the Kupffer cells (Hodges 1987). Androgen therapy may stimulate the phagocytic activity of the RES, so that macrophages are released from storage sites and trapped in the lung. In the lung, these phagocytic cells extract the 99mTc-labeled colloid (Hladik et al. 1987 b).
Quality Control Radiochemical Purity. The European Pharmacopeia requires thin-layer chromatography on silica gel fiberglass sheets and a migration distance 10±15 cm for the identification of impurities, using 0.9% sodium chloride solution (saline) as solvent. Free 99mTcsodium pertechnetate is measured at an Rf of 1.0, and 99mTc-tin colloid is identified at the origin. The radiochemical purity of 99mTc-tin colloid should not be less than 95% (Council of Europe 2005) The analysis of radiocolloids is based on the determination of free 99mTc-Na-pertechnetate, since colloidal activity remains at the start. Hydrolized 99mTc activity cannot be distinguished from the 99mTc-tin colloid. Recommended Methods Thin-layer chromatography using saline ore acetone as solvent Thin-layer chromatography (Ph. Eur.) Stationary phase: Solvent: Developing time:
Gelman ITLC-SG (fiberglass), 2 ´ 10 cm Saline 10 min
Rf values:
99m
Tc-tin colloid: Tc-reduced, colloidal: Tc-pertechnetate:
99m 99m
0.0±0.1 0.0±0.1 0.9±1.0 (< 5%)
TLC using saline is described for: 99mTc-tin colloid (Amerscan Hepatate II). TLC using acetone has been in clinical use for: 99mTc-tin colloid, 99mTc±Nanocoll and 99mTc-(Re)-sulphide colloids.
203
204
12.3
99m
Tc-Labeled Colloids
Quantification of labeled components. Each chromatogram is measured (TLC linear analyzer or gamma counter), and the regional radioactivities are expressed as a percentage of the total recovered counts: 99m
Tc-(tin) colloid (%) = 100 ± F
where F (%) = 99mTc-Na-pertechnetate (free). Results of analysis (12 samples) Results were obtained using thin-layer chromatography and saline as solvent. Labeling and stability
15 min (%)
3 h (%)
99m
99.0 Ô 0.37 1.0 Ô 0.39
98.7 Ô 0.35 1.3 Ô 0.39
Tc-tin colloid Tc-Na-pertechnetate
99m
Bioassay of Colloidal Suspensions. To assure a particle size in the colloidal range (£ l lm), the European Pharmacopeia recommends a physiological test in mice. At least 80% of the intravenously injected radiocolloid should localize in the liver and spleen of three mice. Lung uptake should not exceed 5%.
Pharmacokinetic Data Intravenously injected colloids distribute within the body according to the phagocytic function of the reticuloendothelial system (RES). Size has considerable influence on the biodistribution of colloidal particles. With a particle size of 0.3±0.6 lm, 80±90% of the radioactivity is seen in the liver, with 5±10% seen in the spleen and 5±9% in the bone marrow (Adams et al. 1980; Colombetti 1974; Lin and Winchell 1972; Nelp 1975; Whateley and Steele 1985). Larger colloidal particles show increased splenic uptake, whereas smaller particles localize in the bone marrow (Schuind et al. 1984; Subramanian and McAfee 1970). Increased splenic uptake has been seen with decreased liver function, i.e., cirrhosis (Atkins et al. 1975). Extrahepatic accumulation of 99mTc-labeled colloids is also seen in the bone marrow in the case of hyperplastic bone marrow and with certain hematological disorders (Hæfer and Egert 1963; Hæfer et al. 1964; Nelp and Bower 1969). Occasionally, uptake has been observed in the lung and kidneys (Klingensmith et al. 1976). In healthy persons, the colloid is rapidly removed from the blood by phagocytosis, mainly in the liver. The colloid disappearance rate has been used to estimate liver blood flow (Vetter et al. 1954). The clearance half-time of colloidal radiogold in male and female patients without liver or circulatory disorders was measured as 2.57 and 2.64 min, respectively; patients with liver cirrhosis showed a considerable increase of clearance half-times (mean 7.37 and 7.29 min). Inorganic colloids may remain within the macrophages indefinitely. However, 99mTctin colloid is eliminated from the fixed macrophages of the liver and spleen with halftimes of approximately 71 and 37 h, respectively (Lin and Winchell 1972). The metabolism of soluble bivalent tin was studied in rats after intravenous injection of [113Sn]SnCl2 ´ 2H20 (30 lCi, no carrier added). It was apparent that tin(II)-chlo-
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
ride is rapidly cleared from the circulation, accumulating mainly in the liver (56.2% after 24 h) and spleen (6.9% after 24 h). The elimination from the liver followed an effective half-time of 85 days, from the spleen, of 50 days (Marciniak 1981). Toxicity studies. Fourteen-day studies in mice and dogs (intravenous injection) produced no significant signs of toxicity at levels of 3,108 and 490 times the maximum human dose (£ 0.2 mg/kg). The acute chemical toxicity of SnCl2 ´ 2H2O was determined after the intravenous injection of 1±12 mg Sn2+/kg body weight in rats. The animals were observed for 30 days for signs of toxicity or death. The LD50 value of SnCl2 ´ 2H2O was determined in rats as 7.83 mg Sn2+/kg body weight. Lethality was observed with doses exceeding 3 mg Sn2+/ kg body weight; death occurred within 24 h after the intravenous injection (Marciniak 1981).
Radiation Dose The liver, spleen, and red marrow are the most exposed organs. Calculations of the absorbed radiation dose resulting from liver and spleen scintigraphy are based on technetium-labeled colloids (International Commission on Radiological Protection 1987). The effective dose equivalent is 0.014 mSv/MBq. The effective whole-body dose in adults (70 kg) resulting from an intravenous injection of 185 MBq of 99mTc-tin colloid is 2.6 mSv. The effective dose equivalent per ICRP 62 has been replaced by the quantity effective dose. Values per unit administered activity were published in Addendum 1 (International Commission on Radiological Protection 1991). Values calculated accordingly are slightly lower than the effective whole body doses presented here.
Storage and Stability Storage. The lyophilized kit is stored at 2±8 8C. Stability.
99m
Tc-tin colloid injection is stable for 6 h after the preparation.
References Adams FG, Horton PW, Selim SM (1980) Clinical comparison of three liver scanning agents. Eur J Nucl Med 5:237±239 Atkins HL, Cloutier RJ, Lathrop KA et al (1975) Studies of the reticuloendothelial system (RES). III. Blockade of the RES in man. J Nucl Med 16:108A±108B Colombetti LG (1974) 99mTc-Sn-colloid for liver dynamic studies. Radiobiol Radiother 15:47±53 Council of Europe (2005) Technetium 99mTc tin colloid injection. European pharmacopeia 5.0, monograph no 689. Council of Europe, Maisonneuve, Sainte-Ruffine Hladik WB, III, Gregorio N, Braun TL, Stathis VJ, Ponto JA (1987 a) Radiopharmaceutical information and consultation services. In: Hladik WB, III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, p 392
205
206
12.3
99m
Tc-Labeled Colloids
Hladik WB, III, Ponto JA, Lentle BC, Laven DL (1987 b) Iatrogenic alterations in the biodistribution of radiotracers as a result of drug therapy: reported instances. In: Hladik WB, III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 189±219 Hodges R (1987) Iatrogenic alterations in the biodistribution of radiotracers as a result of drug therapy: theoretical considerations. In: Hladik WB, III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 165±188 Hæfer R, Egert H (1963) Radiogoldverteilung im Knochenmark [in German]. Bull Schweiz Akad Med Wiss 19:36±46 Hæfer R, Ogris E, Pfeiffer G (1964) Kolloidspeicherung im Knochenmark bei Bluterkrankungen. Wien Z Inn Med 45:330±335 International Commission on Radiological Protection (1987) Technetium-labeled colloids. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, pp 179±183 International Commission on Radiological Protection (1991) In: Annals of the ICRP, radiological protection in biomedical research, ICRP Publication 62, vol 22, no 3. Pergamon, Oxford, pp 25±28 Klingensmith WC III, Tsan MF, Wagner HN Jr (1976) Factors affecting the uptake of 99mTc-sulfur colloid by the lung and kidney. J Nucl Med 17:681 Lin MS, Winchell HS (1972) A ªkitº method for the preparation of a technetium-tin(II) colloid and a study of its properties. J Nucl Med 13:58±65 Marciniak M (1981) Bivalent tin metabolism and toxicity after intravenous injection in rats. Acta Physiol Pol 32:2 Nelp WB (1975) An evaluation of colloids for RES function studies. In: Subramanian G, Rhodes BA, Cooper JF, Sodd VJ (eds) Radiopharmaceuticals. Society of Nuclear Medicine, New York, pp 349±355 Nelp WB, Bower RE (1969) The quantitative distribution of the erythron and the RE cell in the bone marrow organ of man. Blood 34:276±280 Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radio-pharmaceutical formulation problems. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 268±289 Schuind F, Schoutens A, Verhas M, Verschaeren A (1984) Uptake of colloids by bone is dependent on bone blood flow. Eur J Nucl Med 9:461±463 Subramanian G, McAfee JG (1970) Stannous oxide colloid labeled with 99mTc or 113In for bone marrow imaging. J Nucl Med 11:365±366 Vetter H, Falkner R, Neumayr A (1954) The disappearance rate of colloidal radiogold form the circulation and its application to the estimation of liver blood flow in normal and cirrhotic patients. J Clin Invest 33:1594 Whateley TL, Steele G (1985) Particle size and surface charge studies of a tin colloid radiopharmaceutical for liver scintigraphy. Eur J Nucl Med 19:353±357
Chapter 12 Monographs of
12.3.1.2
99m
Tc Pharmaceuticals
99m
Tc-Rhenium Sulfide Colloid (Size Range: 0.3±1.0 lm)
I. Zolle Chemical name
Listed trade names
99m
Tc colloidal rhenium sulTechnetium fide injection (Ph. Eur.)
HepatoCis (TCK-1) (1) Sulfotec Sorin (2)
Technetium Tc 99m sulfur colloid injection (USP) 99m
Tc-(Re)-sulfide colloid
99m
Tc-sulfur colloid
Kit components(1)
Kit components(2)
Potassium perrhenate
4.17 mg
Sodium thiosulphate ´ 5 H2O Gelatin
10 mg 166 mg
Water for injection
Potassium perrhenate Sodium thiosulphate ´ 5 H2O Gelatin
4.17 mg 10 mg 100 mg
6 ml
Preparation Each kit consists of one vial with two syringes, one syringe containing 1 ml of 4.6 N HCl, the other 2 ml of 0.65 M citrate buffer (pH 12.0). Each vial contains a sterile, pyrogen-free solution of the ingredients. After adding 5 ml of sterile 99mTc eluate under aseptic conditions to the vial, the reaction is acidified by adding 1 ml of 4.6 N HCl (syringe 1). The reaction vial is placed into a boiling water bath for 5 min. After cooling, 2 ml of 0.65 M citrate buffer solution (syringe 2) are injected into the vial. The resulting pH should be between 3.5 and 6.0 on pH paper. The manufacturer's instructions should be followed. 99mTc-(Re)-sulfide colloid is a sterile, pyrogen-free, light brown, solution (14 ml), suitable for intravenous injection.
Description of the Kit 99m
Tc-(Re)-sulfide colloid is formed at acidic pH in the boiling water bath. The reaction is based on the formation of colloidal sulfur and technetium heptasulfide (Tc2S7) at acidic pH. Rhenium is used as a carrier (Larson and Nelp 1966; Patton et al. 1966). Ten milligrams of sodium thiosulfate pentahydrate generate 2 mg of colloidal sulfur (Stern et al. 1966). The added 99mTc eluate should not be less than 5 ml, the 99mTc activity not less than 370 MBq (10 mCi). In principle, 99mTc-sulfur colloid and 99mTc-(Re)-sulfide colloid are prepared using similar conditions (Patton et al. 1966; Larson and Nelp 1966); however, the original for-
207
208
12.3
99m
Tc-Labeled Colloids
mulation did not contain K-perrhenate carrier. Gelatin was used as a stabilizer (Stern et al. 1966; Haney et al. 1971). 99m Tc-(Re)-sulfide colloid and 99mTc-sulfur colloid, respectively, show a particle size distribution mainly between 0.3 and 0.8 lm. Factors causing low colloid formation (low specific activity) are primarily related to pH, incorrect order of mixing, low heating temperature, heating a large volume, inadequate boiling time, or a defect of kit formulation. 99mTc eluate used for colloid preparation should be obtained from a generator by daily elution in order to minimize 99Tc carrier (Ponto et al. 1987). A flocculent precipitate is formed in the presence of Al3+ cation (1 lg/ml) (Haney et al. 1971; Ponto et al. 1987).
Clinical Applications Intravenous injection: Liver and spleen scintigraphy Bone marrow scintigraphy Oral application: Digestive transit scintigraphy Gastroduodenal motor activity Time of Examination Liver and spleen scintigraphy: 15±20 min after the intravenous injection Bone marrow scintigraphy: 1 h after the intravenous injection Digestive transit scintigraphy: Dynamic imaging is started immediately after oral administration of test meal. Recommended Activities for Indications Liver and spleen scintigraphy: 75±150 MBq (2±4 mCi), injected intravenously, slowly 200 MBq maximal activity for single-photon emission computer tomography (SPECT) £ 0.2 mg sulfur colloid/kg body weight Bone marrow scintigraphy: 150 MBq (400 MBq maximum activity) Digestive transit scintigraphy: 37 MBq (1 mCi) in 30 ml water, followed by 300 ml water The manufacturer's instructions should be followed. Pediatric Dose. The amount of radioactivity for infants and children administered for liver and spleen, and bone marrow scintigraphy is based on body weight, using the scaling factors given in Appendix 1, Table A1.2. The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
Additional Information 99m
Tc-(Re)-sulfide colloid should not be injected together with other drugs or components. Diffuse pulmonary accumulation of radiocolloids may result from elevated plasma levels of aluminum in patients with antacid therapy, because the 99mTc-sulfur colloid
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
coprecipitates with larger aggregates of aluminum phosphate (Ponto et al. 1987). A number of clinical conditions associated with pulmonary uptake of 99mTc-labeled colloids have been reported (Hladik et al. 1987 a). Hepatotoxic substances interfere with phagocytosis, causing transient changes such as inhomogeneous or irregular distribution of radiocolloids in the liver and spleen or a shift of uptake from liver to spleen and/or bone marrow. Anesthetics (halothane) affect both phagocytic and catabolic reticuloendothelial system (RES) function, resulting in an increased uptake in the spleen (Hladik et al. 1987 b). The plasma expander dextran or protein deficiency may also reduce uptake of 99mTc-labeled colloids by the Kupffer cells (Hodges 1987). Androgen therapy may stimulate the phagocytic activity of the RES, so that macrophages are released from storage sites and trapped in the lung. In the lung these phagocytic cells extract the 99mTc-labeled colloid (Hladik et al. 1987 b). Renal accumulation of 99mTc-sulfur colloid has been reported in transplant patients during rejection and during episodes of acute tubular necrosis. Kanamycin is known to cause acute tubular necrosis (Hodges 1987). Gastric emptying has been studied using solid meals to which the labeled colloid (99mTc-(Re)-sulfide colloid or 99mTc-sulfur colloid) was added (Stacher and Bergmann 1992). After 6 h of fasting, the patient is allowed to eat the test meal. From the plot of percent activity versus time, the half-time of gastric emptying is determined. Depending on the consistency of the test meal (liquid or solid), a shorter (10±15 min) or longer (50±80 min) half-time is measured. Meal size and composition must be standardized. Delayed emptying is associated with a number of disease states. Orally administered colloids are not absorbed from the gastrointestinal tract.
Quality Control Radiochemical Purity. The European Pharmacopeia requires paper chromatography (distance 10±15 cm) for the identification of impurities using 0.9% sodium chloride solution (saline) as solvent. Free 99mTc-pertechnetate is measured at Rf 0.6 and 99mTc(Re)-sulfide colloid is identified at the origin. The radiochemical purity of 99mTc-(Re)-sulfide colloid and 99mTc-sulfur colloid, respectively, should not be less than 92% (Council of Europe 2005 a, b). The analysis of radiocolloids is based on the determination of free 99mTc-Na-pertechnetate, since colloidal activity remains at the start. Hydrolized 99mTc activity cannot be distinguished from the 99mTc-(Re)-sulfide colloid. Paper chromatography (Ph. Eur.) Stationary phase: Solvent: Developing time:
Whatman No. 1 paper, 2 ´ 10 cm Saline (0.9% NaCl) 10 min
Rf values:
99m
Tc-(Re)-sulfide colloid: Tc reduced, hydrolized Tc-pertechnetate:
99m 99m
0.0±0.1 (> 92%) 0.0±0.1 0.6±0.7
209
210
12.3
99m
Tc-Labeled Colloids
Recommended Methods Thin-layer chromatography on Gelman silica gel fiberglass sheets using acetone as solvent has been recommended for the identification of free 99mTc-pertechnetate at the solvent front (Rf = 1.0) and 99mTc-(Re)-sulfide colloid at the origin. This method has been in clinical use for: 99mTc-(Re)-sulfide colloid, 99mTc-tin colloid, and 99mTc-Nanocoll. Quantification of labeled components. Each chromatogram is measured (TLC linear analyzer or gamma counter), and the regional radioactivities are expressed as a percentage of the total recovered counts: 99m
Tc-(Re)-sulfide colloid (%) = 100 ± F
where F (%) = 99mTc-Na-pertechnetate (free). Results of analysis (12 samples) Results were obtained using thin-layer chromatography and acetone as solvent. Labeling and stability
15 min (%)
3 h (%)
99m
97.3 Ô 0.47 2.7 Ô 0.38
96.7 Ô 0.57 3.3 Ô 0.97
Tc-(Re)-sulfide colloid Tc-pertechnetate
99m
Bioassay of Colloidal Suspensions. To assure a particle size in the colloidal range (£ 1 lm), the European Pharmacopeia recommends a physiological test in mice. At least 80% of the intravenously injected radiocolloid should localize in the liver and spleen of three mice. Lung uptake should not exceed 5%.
Pharmacokinetic Data Intravenously injected colloids distribute within the body according to the phagocytic function of the RES. Size has considerable influence on the biodistribution of colloidal particles. With a particle size of 0.3±0.6 lm, 80±90% of the radioactivity is seen in the liver, 4±8% in the spleen, and 3±5% in the bone marrow (Adams et al. 1980; Nelp 1975). Larger colloidal particles show increased splenic uptake, whereas smaller particles localize in the bone marrow (Nelp and Bower 1969; Schuind et al. 1984). Increased splenic uptake has been seen with decreased liver function, i.e., cirrhosis (Atkins et al. 1975). Extrahepatic accumulation of 99mTc-labeled colloids is also seen in the bone marrow in the case of hyperplastic bone marrow and with certain hematological disorders (Hæfer and Egert 1963; Hæfer et al. 1964). Occasionally, uptake has been observed in the lung and kidneys (Klingensmith et al. 1976). 99m Tc-(Re)-sulfide colloid is rapidly extracted from the blood circulation by phagocytosis, approximately 94% in one passage. The colloid disappearance rate has been used to estimate liver blood flow (Vetter et al. 1954). The clearance half-time of colloidal radiogold in male and female patients without liver or circulatory disorders was measured as 2.57 and 2.64 min, respectively; patients with liver cirrhosis showed a considerable increase of clearance half-times (means of 7.37 and 7.29 min). For the mea-
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
surement of plasma clearance, a high radiochemical purity of the colloid is essential (Alavi 1982). Inorganic colloids may remain within the macrophages indefinitely. It has been reported, however, that 99mTc-labeled sulfur colloid may be metabolized and excreted (Warbick-Cerone and Phythian 1982). However, the urinary excretion (in 48 h) measured in three patients was less than 4% of the injected radioactivity (Larson and Nelp 1966). No signs of toxicity were observed with large doses of 99mTc-sulfur colloid (40 mg sulfur/kg) after intravenous injection in mice over a period of 4±7 days (Haney et al. 1971).
Radiation Dose The most exposed organs are the liver, spleen, and red marrow. Calculations of the absorbed radiation dose resulting from liver and spleen scintigraphy are based on technetium-labeled colloids (International Commission on Radiological Protection 1987). The effective dose equivalent is 0.014 mSv/MBq. The effective whole-body dose in adults (70 kg) resulting from an intravenous injection of 185 MBq of 99mTc-(Re)-sulfide colloid is 2.6 mSv. Calculations of the absorbed dose resulting from the oral application of 99mTc-(Re)sulfide colloid are based on ICRP Publication 53 (International Commission on Radiological Protection 1987 b) for nonabsorbable markers. The effective dose in adults (70 kg) resulting from 37 MBq (1 mCi) of orally administered 99mTc-(Re)-sulfide colloid is approximately 1 mSv. The effective dose equivalent per ICRP Publication 62 has been replaced by the quantity effective dose. Values per unit administered activity were published in Addendum 1 (International Commission on Radiological Protection 1991). Values calculated accordingly are slightly lower than the effective whole-body doses presented here.
Storage and Stability Storage. The kit is stored at room temperature. Stability. The
99m
Tc-(Re)-sulfide colloid injection is stable for 6 h after preparation.
References Adams FG, Horton PW, Selim SM (1980) Clinical comparison of three liver scanning agents. Eur J Nucl Med 5:237±239 Alavi A (1982) Detection of gastrointestinal bleeding with 99mTc-sulfur colloid. Semin Nucl Med 12:126±138 Council of Europe (2005 a) Technetium 99mTc colloidal rhenium sulphide injection. European pharmacopeia 5.0, monograph, no 126. Council of Europe, Maisonneuve, Sainte-Ruffine Council of Europe (2005 b) Technetium 99mTc sulfur colloid injection. European pharmacopeia 5.0, monograph, no 131. Council of Europe, Maisonneuve, Sainte-Ruffine Haney TA, Ascanio I, Gigliotti JA, Gusmano EA, Bruno GA (1971) Physical and biological properties of a 99mTc-sulfur colloid preparation containing disodium edetate. J Nucl Med 12:64±68
211
212
12.3
99m
Tc-Labeled Colloids
Hladik WB III, Gregorio N, Braun TL, Stathis VJ, Ponto JA (1987 a) Radiopharmaceutical information and consultation services. In: Hladik WB, III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, p 392 Hladik WB III, Ponto JA, Lentle BC, Laven DL (1987 b) Iatrogenic alterations in the biodistribution of radiotracers as a result of drug therapy: reported instances. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 189± 219 Hodges R (1987) Iatrogenic alterations in the biodistribution of radiotracers as a result of drug therapy: theoretical considerations. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 165±188 Hæfer R, Egert H (1963) Radiogoldverteilung im Knochenmark [in German]. Bull Schweiz Akad Med Wiss 19:36±46 Hæfer R, Ogris E, Pfeiffer G (1964) Kolloidspeicherung im Knochenmark bei Bluterkrankungen [in German]. Wien Z Inn Med 45:330±335 International Commission on Radiological Protection (1987 a) Technetium-labelled colloids (1987) In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, pp 179±183 International Commission on Radiological Protection (1987 b) Technetium-labelled non-absorbable markers (1987) In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol. 18, no. 1±4. Pergamon, Oxford, pp 225± 226 International Commission on Radiological Protection (1991) In: Annals of the ICRP, Radiological protection in biomedical research, ICRP Publication 62, vol 22, no 3. Pergamon, Oxford, pp 25±28 Klingensmith WC III, Tsan MF, Wagner HN Jr (1976) Factors affecting the uptake of 99mTc-sulfur colloid by the lung and kidney. J Nucl Med 17:681 Larson SM, Nelp WB (1966) Radiopharmacology of a simplified technetium-99m-colloid preparation for photoscanning. J Nucl Med 7:817±826 Nelp WB (1975) An evaluation of colloids for RES function studies. In: Subramanian G, Rhodes BA, Cooper JF, Sodd VJ (eds) Radiopharmaceuticals. Society of Nuclear Medicine, New York, pp 349±355 Nelp WB, Bower RE (1969) The quantitative distribution of the erythron and the RE cell in the bone marrow organ of man. Blood 34:276±280 Patton, DP, Garcia, EN, Webber, MM (1966) Simplified preparation of technetium-99m-sulfide colloid for liver scanning. Am J Roentgenol Radium Ther Nucl Med 97:880 Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radio-pharmaceutical formulation problems. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 268±289 Schuind F, Schoutens A, Verhas M, Verschaeren A (1984) Uptake of colloids by bone is dependent on bone blood flow. Eur J Nucl Med 9:461±463 Stacher G, Bergmann H (1992) Scintigraphic quantitation of gastrointestinal motor activity and transport: oesophagus and stomach. Eur J Nucl Med 19:815±823 Stern HS, McAfee JG, Subramanian G (1966) Preparation, distribution and utilization of technetium-99m-sulfur colloid. J Nucl Med 7:665±675 United States Pharmacopeial Convention (2005) United States Pharmacopeia (USP) 28 official monographs: Technetium Tc 99m sulfur colloid injection. United States Pharmacopeial Convention, Rockville, Md, p 1865 Vetter H, Falkner R, Neumayr A (1954) The disappearance rate of colloidal radiogold form the circulation and its application to the estimation of liver blood flow in normal and cirrhotic patients. J Clin Invest 33:1594 Wagner HN Jr, Iio M (1964) Studies of the reticuloendothelial system (RES). III. Blockade of the RES in man. J Clin Invest 42:1525±1532 Warbick-Cerone A, Phythian JR (1982) The role of endocytosis in the localization of radiotracers. In: Anghileri LJ (ed) General processes of radiotracer localization, vol 1. CRC Press, Boca Raton, p 173
Chapter 12 Monographs of
12.3.1.3
99m
Tc Pharmaceuticals
99m
Tc-Albumin Microcolloid (Size Range: 0.2±2.0 lm)
I. Zolle Chemical name
Listed trade names
Human albumin microaggregates
AlbuRes
Solco (1)
Technetium albumin colloid injection (USP)
Microlite
DuPont Merck (2)
99m
Tc-albumin colloid
99m
Tc-HSA-microcolloid
Kit components(1)
Kit components(2)
HSA-microcolloid
2.5 mg
HSA-microcolloid
1.0 mg
Stannous chloride ´ 2 H2O
0.4 mg
Stannous chloride ´ 2 H2O
0.17 mg
Monobasic sodium phosphate
0.458 mg
Human albumin
Disodium phytate
0.25 mg
Glucose anhydrous Poloxamer 238
15 mg 2.5 mg
Disodium medronate Sodium phosphate Poloxamer 188
10 mg 0.12 mg 10 mg 1.1 mg
Preparation The kits contain the sterile, lyophilized, preformed microcolloid in a multidose vial. Labeling with 99mTc-pertechnetate is carried out under aseptic conditions by adding 1± 5 ml of 99mTc eluate (maximum of 3 GBq). The reaction is allowed to proceed at room temperature for 5 min. 99mTc-microaggregates form a sterile, pyrogen-free, milky-white solution suitable for intravenous injection. The pH is 4.0±7.0 on pH paper.
Description of the Kit Preformed albumin microcolloid is easily labeled with reduced technetium at room temperature, provided the amount of stannous chloride is not less than 6 lg. No heating or pH adjustments are required. More than 90% of 99mTc-albumin microcolloids show a size distribution between 0.2 and 2.0 lm (Chia 1986; Honda et al. 1970; Taplin et al. 1964 a; Yamada et al. 1969). 99m Tc eluate used for labeling the preformed colloid should be obtained from a generator by daily elution in order to minimize 99Tc carrier and should comply with specifications stated in the European Pharmacopeia. A flocculent precipitate is formed in the presence of Al3+ ion (> 1 lg/ml) (Ponto et al. 1987).
213
214
12.3
99m
Tc-Labeled Colloids
Clinical Applications Intravenous injection: Liver and spleen scintigraphy Time of Examination. The time of examination should be 15±60 min after intravenous injection. Recommended Activities for Indications Liver and spleen scintigraphy: 40±150 MBq (1±4 mCi), injected intravenously 200 MBq (5.4 mCi) maximal activity for single-photon emission computer tomography (SPECT) £ 0.025 mg microaggregates/kg body weight The manufacturer's instructions should be followed. Pediatric Dose. The amount of radioactivity for infants and children administered for liver/spleen scintigraphy is based on body weight, using the scaling factors given in Appendix 1, Table A1.2. The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
Additional Information The use of 99mTc-albumin microcolloid in patients with a history of hypersensitivity to human albumin is contraindicated. 99mTc-albumin microcolloid should not be injected together with other drugs or components. Albumin aggregates in the colloidal size range are obtained by heat denaturation of a 1% solution of human serum albumin (HSA) in alkaline medium (pH 10.0) (Honda et al. 1970). The size of the albumin colloid is affected by the pH, temperature, and the mode of agitation (Taplin et al. 1964 a). Diffuse pulmonary accumulation of radiocolloids may result from elevated plasma levels of aluminum in patients with antacid therapy (Ponto et al. 1987). A number of clinical conditions associated with pulmonary uptake of 99mTc-labeled colloids have been reported (Hladik et al. 1987 a). Hepatotoxic substances interfere with phagocytosis, causing transient changes, such as inhomogeneous or irregular distribution of radiocolloids in the liver/spleen or a shift of uptake from liver to spleen and/or bone marrow. Anesthetics (halothane) affect both phagocytic and catabolic reticuloendothelial system (RES) function, resulting in an increased uptake in the spleen (Hladik et al. 1987 b). The plasma expander dextran or protein deficiency may also reduce uptake of 99mTc-labeled colloids by the Kupffer cells (Hodges 1987).
Quality Control Radiochemical Purity. 99mTc-albumin microcolloid is not described in the European Pharmacopeia. Thin-layer chromatography is recommended by the manufacturer, using 85% methanol as solvent. Free 99mTc-sodium pertechnetate is measured at Rf 0.7 and
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
99m
Tc-albumin microcolloid is identified at the origin. The radiochemical purity of Tc-albumin microcolloid should not be less than 95%. The analysis of radiocolloids is based on the determination of free 99mTc-Na-pertechnetate, since colloidal activity remains at the start. Hydrolized 99mTc-activity cannot be distinguished from 99mTc-HSA colloid. 99m
Recommended Methods Thin-layer chromatography (USP 28) Thin-layer chromatography (USP) Stationary phase: Solvent: Developing time:
Gelman ITLC-SG (fiberglass), 2 ´ 9.5 cm Methyl ethyl ketone (MEK) 5 min
Rf values:
99m
Tc-HSA microcolloid: Tc reduced, hydrolized Tc-pertechnetate:
99m 99m
0.0±0.1 0.0±0.1 0.9±1.0 (< 5%)
Quantification of labeled components. Each chromatogram is measured (TLC linear analyzer or gamma counter), and the regional radioactivities are expressed as a percentage of the total recovered counts: 99m
Tc-HSA microcolloid (%) = 100 ± F F (%) = 99mTc-Na-pertechnetate (free).
Results of analysis (12 samples) Results were obtained using the analytical method described by the manufacturer. Labeling and stability
15 min (%)
3 h (%)
99m
95.9 Ô 0.26 4.1 Ô 0.10
94.7 Ô 0.32 5.3 Ô 0.12
Tc-HSA microcolloid Tc-Na-pertechnetate
99m
Pharmacokinetic Data Intravenously injected colloids distribute within the body according to the phagocytic activity of the RES. Size has considerable influence on the biodistribution of colloidal particles. With a particle size of 0.3±0.6 lm, 80±90% of the radioactivity is extracted by the liver, 4±8% by the spleen, and < 1% by the bone marrow (Nelp 1975). Larger colloidal particles show increased splenic uptake, whereas smaller particles (nanocolloids) localize in the bone marrow (10±15%) (Nelp and Bower 1969; Schuind et al. 1984). In healthy persons, 99mTc-HSA microcolloid is rapidly removed from the blood by phagocytosis, approximately 94% in one passage (Shaldon et al. 1961). Fifteen minutes after the intravenous injection, only approximately 1% of the radioactivity is measured in blood (Chia 1986). The colloid disappearance rate has been used to estimate liver blood flow. Following the intravenous injection of tracer quantities (less than 0.25 mg/ kg body weight), elimination half-times of 2±3 min were measured (Kitani and Taplin
215
216
12.3
99m
Tc-Labeled Colloids
1972). Using a smaller colloid (10±20 nm), a mean half-time of 2.6 min was reported (Iio et al. 1963). Values exceeding 3.0 min indicate reduced hepatic blood flow or a decreased liver function (cirrhosis), as observed in patients with various liver diseases (Iio et al. 1963; McAfee et al. 1975; Palmer et al. 1971; Taplin et al. 1964 b; Wagner et al. 1963). In patients with reduced hepatic uptake, the concentration of radioactivity within the spleen is increased. 99m Tc-albumin microcolloid is metabolized in the Kupffer cells by proteolytic enzymes and eliminated from the liver (Reske et al. 1981; Taplin et al. 1964 a). In the case of 99mTc-albumin millimicrospheres, biological half-times of 10 min and 4.7 h were measured (Reske et al. 1981). In patients with overactive digestive function, RES 99mTclabeled degradation products have been observed in the bile, accumulating in the gallbladder during the first 2±3 h post-intravenous injection (Kitani and Taplin 1972). Repeated injections of high doses (5 mg/kg) of aggregated albumin (£ 80 nm) over a 2-month period have been well tolerated in three subjects, showing no effect on the clearance rate when compared with control subjects (Iio et al. 1963). Subcutaneous injection of small doses (0.02 mg/kg) as well as a saturation dose of 4 mg/kg showed no evidence of hypersensitivity (Iio et al. 1963).
Radiation Dose The liver, spleen, and red marrow are the most exposed organs. Calculations of the absorbed radiation dose resulting from liver and spleen scintigraphy are based on technetium-labeled colloids (International Commission on Radiological Protection 1987). The effective dose equivalent is 0.014 mSv/MBq. The effective whole-body dose in adults (70 kg) resulting from an intravenous injection of 185 MBq of 99mTc-albumin microcolloid is 2.6 mSv. The effective dose equivalent per ICRP Publication 62 has been replaced by the quantity effective dose. Values per unit administered activity were published in Addendum 1 (International Commission on Radiological Protection 1991). Values calculated accordingly are slightly lower than the effective whole-body doses presented here.
Storage and Stability Storage. The lyophilized kit is stored at 2±8 8C. Stability. tion.
99m
Tc-albumin microcolloid injection solution is stable for 3 h after prepara-
References Chia HL (1986) Particulate radiopharmaceuticals in nuclear medicine. In: Cox PH (ed) Radiopharmacy and radiopharmacology yearbook II. Grune and Stratton, New York Hladik WB III, Gregorio N, Braun TL, Stathis VJ, Ponto JA (1987 a) Radiopharmaceutical information and consultation services. In: Hladik WB, III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, p 392
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Hladik WB III, Ponto JA, Lentle BC, Laven DL (1987 b) Iatrogenic alterations in the biodistribution of radiotracers as a result of drug therapy: reported instances. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 189±219 Hodges R (1987) Iatrogenic alterations in the biodistribution of radiotracers as a result of drug therapy: theoretical considerations. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 165±188 Honda T, Kazem I, Croll MN, Brady LW (1970) Instant labeling of macro- and microaggregated albumin with 99mTc. J Nucl Med 11:580±585 Iio M, Wagner HN Jr, Scheffel U, Jabbour B (1963) Studies of the reticuloendothelial system (RES). I. Measurement of the phagocytic capacity of the RES in man and dog. J Clin Invest 42:417±426 International Commission on Radiological Protection (1987) Technetium-labelled colloids. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, pp 179±183 International Commission on Radiological Protection (1991) ICRP Publication 62. In: Annals of the ICRP, radiological protection in biomedical research, vol 22, no 3. Pergamon, Oxford, pp 25±28 Kitani K, Taplin GV (1972) Biliary excretion of 99mTc-albumin microaggregate degradation products (a method for measuring Kupffer cell digestive function?). J Nucl Med 13:260±264 McAfee JG, Ause RG, Wagner HN Jr (1975) Diagnostic value of scintillation scanning of the liver. Arch Intern Med 116:95±110 Nelp WB (1975) An evaluation of colloids for RES function studies. In: Subramanian G, Rhodes BA, Cooper JF, Sodd VJ (eds) Radiopharmaceuticals. Society of Nuclear Medicine, New York, pp 349±355 Nelp WB, Bower RE (1969) The quantitative distribution of the erythron and the RE cell in the bone marrow organ of man. Blood 34:276±280 Palmer DI, Rifkind D, Brown DW (1971) 131I-labeled colloidal serum albumin in the study of reticuloendothelial system function. III. Phagocytosis and catabolism compared in normal, leukemia, and immunosuppressed human subjects. J Infect Dis 123:465±469 Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radio-pharmaceutical formulation problems. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 268±289 Reske SN, Vyska K, Feinendegen LE (1981) In vivo assessment of phagocytic properties of Kupffer cells. J Nucl Med 22:405 Schuind F, Schoutens A, Verhas M, Verschaeren A (1984) Uptake of colloids by bone is dependent on bone blood flow. Eur J Nucl Med 9:461±463 Shaldon S, Chiandussi L, Guevara L, Caesar J, Sherlock S (1961) The estimation of hepatic blood flow and intrahepatic shunted blood flow by colloidal heat-denatured human serum albumin labeled with 131I. J Clin Invest 40:1346±1354 Taplin GV, Dore EK, Johnson DE (1964) Hepatic blood flow and reticuloendothelial system studies with radiocolloids. In: Kniseley RM et al (eds) Dynamic clinical studies with radioisotopes. US Atomic Energy Commission, Division of Technical Information, TID 7678, pp 285±317 Taplin GV, Johnson DE, Dore EK, Kaplan HS (1964) Suspensions of radioalbumin aggregates for photoscanning the liver, spleen, lung and other organs. J Nucl Med 5:259±275 United States Pharmacopeial Convention (2005) United States Pharmacopeia (USP) 28 official monographs: Technetium Tc 99m albumin colloid injection. United States Pharmacopeial Convention, Rockville, Md, p 1851 Wagner HN Jr, Iio M, Hornick RB (1963) Studies of the reticuloendothelial system (RES). II. Changes in the phagocytic capacity of the RES in patients with certain infections. J Clin Invest 42:427±434 Yamada H, Johnson DE, Griswold ML et al (1969) Radioalbumin microaggregates for reticuloendothelial organ scanning and function assessment. J Nucl Med 10:453±454
217
218
12.3
99m
Tc-Labeled Colloids
12.3.1.4
99m
Tc-Albumin Millimicrospheres (Size Range: 0.3±1.0 lm)
I. Zolle Chemical name Albumin millimicrospheres HSA millimicrospheres milli-HAM 99m
Tc-HSA millimicrospheres
99m
Tc-millimicrospheres
99m
Tc-milli-HAM Albumin millimicrospheres (< 1 lm) (Small square 50 ´ 50 lm, 600-fold) Listed trade names
Kit components HSA millimicrospheres
2.0 mg
Stannous chloride ´ 2 H2O
0.5 mg
Cysteine
0.2 mg
Pluronic F68
2.0 mg
Sodium chloride
Nanotec
Sorin
18.0 mg
Preparation The kit contains sterile, lyophilized, preformed millimicrospheres in a multidose vial. Labeling with 99mTc-pertechnetate is carried out under aseptic conditions by adding 1± 5 ml of 99mTc eluate (maximum of 3 GBq (80 mCi) to obtain a specific activity of 600 MBq/ml/0.4 mg). The reaction is allowed to proceed at room temperature for 15 min. 99mTc-millimicrospheres are a sterile, pyrogen-free, opalescent solution suitable for the intravenous injection. The pH is 6.0±7.5.
Description of the Kit Preformed albumin millimicrospheres are easily labeled with reduced technetium at room temperature (Zolle et al. 1970, 1973). No heating or pH adjustments are required. Consistently high labeling yields were obtained with milli-HAM containing tin (II) salt (Villa et al. 1976), and when milli-HAM were labeled by electrolytic reduction using a tin anode and a platinum cathode (Angelberger et al. 1985; Kæhn et al. 1985). More than 90% of 99mTc-albumin millimicrospheres show a size distribution between 0.3 and 0.8 lm (Kæhn et al. 1985; Scheffel et al. 1972).
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
99m Tc eluate used for labeling the preformed millimicrospheres should be obtained from a generator by daily elution in order to minimize 99mTc carrier and should comply with specifications stated in the European Pharmacopeia. The presence of Al3+ ion (> 1 lg/ml) in the eluate may cause aggregation of the colloidal particles (Ponto et al. 1987). For inhalation of 99mTc-albumin millimicrospheres, the vial (Nanotec) is transferred to an aerosol generator. Dry aerosols are obtained with 99mTc-milli-HAM suspended in ethanol (Angelberger et al. 1985; Kæhn et al. 1985). These have advantages over moist aerosols, showing higher lung penetration between 20 and 30%, while in the case of aqueous nebulization, only 1±10% of the radioactivity are deposited in the lung (Santolicandro and Giuntini 1979).
Clinical Applications Intravenous injection:
Liver and spleen scintigraphy Regional liver perfusion and RES function in cases of impaired liver function (cirrhosis, metal poisoning, transplantation) Bone marrow scintigraphy Nebulization as aerosol: Inhalation scintigraphy Assessment of pulmonary ventilation in patients with chronic obstructive lung disease, and for the differential diagnosis of acute pulmonary embolism in combination with lung perfusion scintigraphy Measurement of mucociliary function Time of Examination Liver and spleen scintigraphy: 10±60 min after the intravenous injection Bone marrow imaging: 45±60 min after the intravenous injection Inhalation scintigraphy: Immediately after inhalation Recommended Activities for Indications Liver and spleen scintigraphy: 40±150 MBq (1±4 mCi), injected intravenously 200 MBq (5.4 mCi) maximal activity for single-photon emission computed tomography (SPECT) £ 0.025 mg millimicrospheres/kg body weight Bone marrow scintigraphy: 185±370 MBq (5±10 mCi), injected intravenously 400 MBq maximum recommended activity Inhalation scintigraphy: 150 MBq (4 mCi) inhaled radioactivity The manufacturer's instructions should be followed. Pediatric Dose. The amount of radioactivity for infants and children administered for liver/spleen and bone marrow scintigraphy is based on body weight, using the scaling factors given in Appendix 1, Table A1.2. The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
219
220
12.3
99m
Tc-Labeled Colloids
Additional Information The use of 99mTc-albumin millimicrospheres in patients with a history of hypersensitivity to human albumin is contraindicated. 99m Tc-albumin millimicrospheres should not be injected together with other drugs or components. For intravenous injection (preferably not through a lying catheter), 99mTc-albumin millimicrospheres should be homogenously suspended to avoid in vivo aggregates. For this reason, the aspiration of blood into the syringe should be avoided. Albumin millimicrospheres are obtained by heating a dispersed solution of human serum albumin (25%) in oil (Zolle et al. 1970, 1973). The size of the albumin particles depends mainly on the degree of homogenization, generally a size distribution between 0.3 and 3 lm is obtained (Zolle et al. 1970). For intravenous injection, particles larger than 1 lm have been removed by differential centrifugation (Angelberger et al. 1985; Kæhn et al. 1985). Hepatotoxic substances interfere with phagocytosis causing transient changes, such as inhomogeneous or irregular distribution of radiocolloids in the liver/spleen, or a shift of uptake from liver to spleen and/or bone marrow. Anesthetics (halothane) affect both phagocytic and catabolic RES function, resulting in an increased uptake in the spleen (Hladik et al. 1987).
Quality Control Radiochemical purity. 99mTc-HSA-millimicrospheres are not described in the European Pharmacopeia. Thin-layer chromatography is recommended by the manufacturer using 85% methanol as solvent. Free 99mTc-pertechnetate is measured at an Rf of 0.6, and 99m Tc-millimicrospheres are identified at the origin. The radiochemical purity of 99mTcmilli-HAM should not be less than 95%. The analysis of radiocolloids is based on the determination of free 99mTc-Na-pertechnetate, since colloidal activity remains at the start. Hydrolized 99mTc-activity cannot be distinguished from 99mTc-milli-HAM. Recommended Methods Thin-layer chromatography Stationary phase: Solvent: Developing time:
Gelman ITLC-SG (fiberglass), 2 ´ 9.5 cm Methanol (85%) 5 min
Rf values:
99m
Tc-milli-HAM: Tc reduced, hydrolized: 99m Tc-pertechnetate: 99m
0.0±0.1 0.0±0.1 0.6±0.7 (< 5%)
Quantification of labeled components. Each chromatogram is measured (TLC linear analyzer or gamma counter) and the regional radioactivities are expressed as a percentage of the total recovered counts:
Chapter 12 Monographs of 99m
99m
Tc Pharmaceuticals
Tc-milli-HAM (%) = 100 ± F
where F (%) = 99mTc-Na-pertechnetate (free). Results of analysis (12 samples) Results were obtained using the analytical method described by the manufacturer. Labeling and stability
15 min (%)
3 h (%)
99m
96.7 Ô 0.57 3.2 Ô 0.59
96.3 Ô 0.49 3.7 Ô 0.48
Tc-HSA millimicrospheres Tc-Na-pertechnetate
99m
99m
Tc-milli-HAM are labeled with a high radiochemical yield and show high stability of the radioactive label.
Pharmacokinetic Data Trace amounts of intravenously injected 99mTc-albumin millimicrospheres (0.02 mg/kg body weight) are rapidly removed from the blood with a half-time of 1.4±2.0 min (Reske et al. 1981; Scheffel et al. 1972). From 83 to 86% is taken up in the liver by phagocytosis; the maximum activity in the liver is reached 5±10 min after the intravenous injection (Scheffel et al. 1972; Zolle et al. 1973). The plasma disappearance rate is related to the particle size of colloids. Using aggregated albumin (10±20 nm), a mean clearance half-time of 2.6 min was reported (Iio et al. 1963). In patients with reduced hepatic uptake, the spleen shows a high concentration of radioactivity (McAfee et al. 1975). 99m Tc-albumin millimicrospheres are metabolized in the Kupffer cells. The elimination of 99mTc-milli-HAM from the liver was shown as a reliable indicator of specific Kupffer-cell function (Reske et al. 1981). A biphasic elimination was observed in man, with a fast (T1/2< 10 min) and a slowly degrading component (T1/2 > 4 h) (Reske et al. 1981; Szabo et al. 1984). In tumor patients without detectable liver metastases or direct tumor invasion, elimination from the liver by phagocytosis was markedly delayed (T1/2 of 8.55 h vs 4.28 h), while the clearance of 99mTc-millimicrospheres from the blood was increased (T1/2 of 1.3 min vs 1.8 min) (Reske et al. 1981). In the rat, 99mTc-milli-HAM have shown a monoexponential removal from the liver (T1/2 of 8.8 h) with increasing intestinal activity 1±6 h after the intravenous injection (Villa et al. 1976). Biliary excretion of degradation products was observed with 99mTcalbumin microaggregates (Kitani and Taplin 1972; Wetterfors et al. 1960). For the application of 99mTc-milli-HAM as an aerosol, preparations with an average diameter of approximately 0.5 lm have shown free diffusion into the lung periphery and high alveolar retention (Agnew et al. 1981; Kæhn et al. 1985). Larger millimicrospheres (1±5 lm) sediment preferentially in the trachea and upper bronchial tree (Weiss et al. 1981). 99m Tc-albumin millimicrospheres are well tolerated without complications. No acute reactions were seen when injecting 5±15 mg/kg body weight in 80 mice (Scheffel et al. 1972). Hypersensitivity reactions are rare and caused mainly by agents used for suspension of 99m Tc-milli-HAM. No cases of anaphylaxis have been reported after aerosol inhalation.
221
222
12.3
99m
Tc-Labeled Colloids
Radiation Dose The liver, spleen, and red marrow are the most exposed organs. Calculations of the absorbed radiation dose resulting from liver and spleen scintigraphy are based on technetium-labeled colloids (ICRP Publication 53, International Commission on Radiological Protection 1987 a). The effective dose equivalent is 0.014 mSv/MBq. The effective whole-body dose in adults (70 kg) resulting from an intravenous injection of 185 MBq (5 mCi) of 99mTc-millimicrospheres is 2.6 mSv. Calculations of the absorbed radiation dose resulting from inhalation of 99mTc-millimicrospheres are based on technetium-labeled aerosols (ICRP Publication 53, International Commission on Radiological Protection 1987 b). It is assumed that the label is released in the lung slowly, with a biological half-time of 24 h, and that the activity is excreted by the kidneys. The effective dose equivalent is 0.015 mSv/MBq. The dose to the bladder wall after inhalation of 150 MBq (4 mCi) is 1.95 mGy. The effective wholebody dose in adults (70 kg) resulting from inhalation of 150 MBq of 99mTc-millimicrospheres is 2.3 mSv. The effective dose equivalent per ICRP 62 has been replaced by the quantity effective dose. Values per unit administered activity were published in Addendum 1 (International Commission on Radiological Protection 1991). Values calculated accordingly are slightly lower than the effective whole-body doses presented here.
Storage and Stability Storage. The lyophilized kit is stored at 2±8 8C. Stability. The
99m
Tc-milli-HAM injection is stable for 6 h after preparation.
References Agnew JE, Bateman JR, Watts M, Paramananda V, Pavia D, Clarke SW (1981) The importance of aerosol penetration for lung mucociliary clearance studies. Chest 80(Suppl):843±846 Angelberger P, Zolle I, Strigl A, Kæhn H, Mostbeck A, Fiedler W (1985) A dry aerosol of 99mTcalbumin-millimicrospheres for lung ventilation scintigraphy, In: Cox PH, Limouris G, Woldring MG (eds) Progress in radiopharmacology, vol 4. Martinus Nijhoff, The Hague, pp 73±86 Hladik WB, III, Ponto JA, Lentle BC, Laven DL (1987 b) Iatrogenic alterations in the biodistribution of radiotracers as a result of drug therapy: reported instances. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 189± 219 Iio M, Wagner HN Jr, Scheffel U, Jabbour B (1963) Studies of the reticuloendothelial system (RES). I. Measurement of the phagocytic capacity of the RES in man and dog. J Clin Invest 42:417± 426 International Commission on Radiological Protection (1987 a) Technetium-labelled colloids (1987) In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4, Pergamon, Oxford, pp 179±183 International Commission on Radiological Protection (1987 b) Technetium-labelled aerosols (1987) In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, pp 217±219
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
International Commission on Radiological Protection (1991) In: Annals of the ICRP, radiological protection in biomedical research, ICRP Publication 62, vol 22, no 3, Pergamon, Oxford, pp 25±28 Kitani K, Taplin GV (1972) Biliary excretion of 99mTc-albumin microaggregate degradation products (a method for measuring Kupffer cell digestive function?). J Nucl Med 13:260±264 Kæhn H, Klech H, Angelberger P, Strigl A, Zolle I, Kummer F, Mostbeck A (1985) Dry aerosol of monodisperse millimicrospheres for ventilation imaging: production, delivery system, and clinical results in comparison with 81mKr and 127Xe. Eur J Nucl Med 10:411±416 McAfee JG, Ause RG, Wagner HN Jr (1975) Diagnostic value of scintillation scanning of the liver. Arch Intern Med 116:95±110 Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radio-pharmaceutical formulation problems. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp. 268±289 Reske SN, Vyska K, Feinendegen LE (1981) In vivo assessment of phagocytic properties of Kupffer cells. J Nucl Med 22:405 Santolicandro A, Giuntini C (1979) Patterns of deposition of labelled monodispersed aerosols in obstructive lung disease. J Nucl Med All Sci 23:115 Scheffel U, Rhodes BA, Natarajan TK, Wagner HN Jr (1972) Albumin microspheres for study of the reticuloendothelial system. J Nucl Med 13:498±503 Szabo Z, Vosberg H, Segall M, Feinendegen LE (1984) Messung der mittleren Retentionszeiten 99m Tc-makierter HSA-Millimikrosphåren in der Leber ± Klinische Ergebnisse bei Patienten mit operiertem Mammakarzinom [in German]. Nucl Med 23:171±176 Villa M, Pretti O, Mosca R, Plassio G, Pasqualini R (1976) Preparation and evaluation of tin-albumin millimicrospheres for labelling with Tc-99m. J Nucl Biol Med 20:168±171 Weiss T, Dorow P, Felix R, Schmutzler H (1981) Pulmonales Aerosolverteilungsmuster und regionale mukoziliåre Clearance bei Patienten mit chronisch obstruktiver Atemwegserkrankung und small airways disease [in German]. Atemw Lungenkrkh 7:172±178 Wetterfors J, Gullberg R, Lilhedahl SO, Birke G, Olhage B (1960) Role of the stomach in albumin breakdown. Acta Med Scand 168:347 Zolle I, Bergmann H, Hæfer R (1973) Millimicrospheres zur Funktionsprçfung des retikuloendothelialen Systems (RES) In: Teil, Fellinger K, Hæfer R (eds) Radioaktive Isotope in Klinik und Forschung, Band 10, 2. Urban & Schwarzenberg, Mçnchen-Berlin, 446±453 Zolle I, Hosain F, Rhodes BA, Wagner HN Jr (1970) Human serum albumin millimicrospheres for studies of the reticuloendothelial system. J Nucl Med 11:379
223
224
12.3
99m
12.3.2
Tc-Labeled Colloids 99m
12.3.2.1
Tc-Labeled Nanocolloids
99m
Tc-Rhenium Sulfide Nanocolloid (Size Range: 10±100 nm)
I. Zolle Chemical name
Listed trade names
Rhenium sulfide nanocolloid
NanoCis (TCK-17) (A+B)
CIS Bio
Tin(II)-sulfide nanocolloid
Lymphoscint (Solco)
GE Healthcare
99m
Tc-(Re)-sulfide nanocolloid
99m
Tc-(Sn)-sulfide nanocolloid
Kit components A
Kit components B
Rhenium sulfide
0.48 mg
Sodium pyrophosphate ´ 10 H2O
3.0 mg
Ascorbic acid
7.0 mg
Stannous chloride ´ 2 H2O
0.5 mg
Gelatin
9.6 mg
Water for injection
1.0 ml
Hydrochloric acid (conc.)
37.4 ll
Preparation The NanoCis kit (TCK-17) consists of two vials, A and B. Vial A contains a sterile, pyrogen-free solution of ingredients. Vial B contains lyophilized sodium pyrophosphate and stannous chloride. Two milliliters of sterile water for injection are added to vial B to dissolve its content. Half a milliliter of solution B is transferred to vial A, and mixed well. Then, 1±2 ml of 99mTc eluate is added under aseptic conditions (not less than 370 MBq [10 mCi] to assure a specific activity of ³ 100 MBq/ml/0.15 mg). The reaction vial is placed into a boiling water bath for 15±30 min. After cooling, the labeled colloid is ready for use. 99m Tc-(Re)-sulfide nanocolloid is a sterile, pyrogen-free, brown solution, suitable for subcutaneous (interstitial) injection. The pH is between 4.0 and 7.0 on pH paper. 99m Tc-Sn(II)-sulfide colloid (Lymphoscint) is prepared by adding 0.2±2 ml of sterile 99m Tc eluate under aseptic conditions (not more than 1.5 GBq [40 mCi]). A volume of approximately 0.5 ml of the 99mTc eluate is recommended by the manufacturer to minimize ionic aluminum. The final volume may be adjusted with oxidant-free saline. The reaction vial is placed into a boiling water bath for 4 min. After cooling, the labeled colloid is ready for use. 99mTc-Sn(II)-sulfide nanocolloid is a sterile, pyrogen-free solution, suitable for subcutaneous (interstitial) injection. The pH is between 4.0 and 7.0 on pH paper.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Description of the Kit 99m
Tc-(Re)-sulfide colloid is formed by reduction with tin pyrophosphate in the boiling water bath. Rhenium sulfide is used as a carrier (Larson and Nelp 1966; Patton et al. 1966). The added 99mTc eluate should not exceed 2 ml, the 99mTc activity should not be less than 370 MBq (10 mCi). Gelatin is used as a stabilizer. The size distribution of 99m Tc-(Re)-sulfide colloid is between 40 and 80 nm, comparable with the previously available 99mTc-(Sb)-sulfide colloid (5±15 nm). 99m Tc-(Sn)-sulfide colloid is prepared by labeling a preformed colloid in the boiling water bath; gelatin is used for stabilization. 99mTc-tin(II)-sulfide colloid has a favorable particle size, namely £ 50 nm. Factors causing low colloid formation (low specific activity) are primarily related to pH, incorrect order of mixing, low heating temperature, heating a large volume, inadequate boiling time, or a defect of kit formulation. 99mTc eluate used for colloid preparation should be obtained from a generator by daily elution in order to minimize 99Tc carrier; preferably, a small volume is added in order to reduce the concentration of Al3+ ion (Ponto et al. 1987).
Clinical Applications Subcutaneous (interstitial) injection: Lymphoscintigraphy Visualization of lymphatic flow and regional lymph nodes in the extremities and the trunk Subdermal or peritumoral injection: Sentinel lymph node (SLN) scintigraphy Oral application: Gastroesophageal scintigraphy Esophageal motility disorders Gastroduodenal motor activity Lymphoscintigraphy is performed for the diagnosis of peripheral edema caused by recurring erysipel or by affected lymph nodes as a result of metastatic infiltration, lymphogranuloma, lymphosarcoma, damage as a result of radiation treatment, or other causes. Other indications include secondary edema caused by blockade of the lymphatic flow, and thrombosis (Lofferer et al. 1974; Mostbeck et al. 1984). Lymphatic drainage from a primary tumor was studied in patients with breast cancer (Ege 1983). Several colloidal preparations have been evaluated (Kaplan et al. 1979, 1985; Nagai et al. 1982; Strand and Persson 1979). SLN imaging can identify the first infected lymph node of a primary tumor before surgery. If the SLN is histologically tumor free, no other lymph node will contain metastatic disease (Alazraki et al. 1997).
225
226
12.3
99m
Tc-Labeled Colloids
Time of Examination Lymphoscintigraphy:
Sequential scintigraphy 15 min after subcutaneous injection up to 1 h Visualization of lymph nodes between 2 and 6 h after injection SLN imaging: Sequential planar scintigraphy 5 ± 10 min postinjection and 1±6 h postinjection (late images) Gastroesophageal scintigraphy: Sequential scintigraphy and static imaging may be performed Recommended Activities for Indications Lymphoscintigraphy of the extremities: 20±75 MBq (0.5±2 mCi) in a volume of 0.2± 0.3 ml, subcutaneous injection into the interdigital spaces of the hands or feet. For a better resorption and to reduce the radiation burden to the injection site, the total dose (£ 185 MBq [5 mCi]) may be divided between two and three injection sites. 40 MBq (1 mCi) maximum activity per injection site The volume of injection should not exceed 0.5 ml Parasternal lymphatics: 20 MBq (0.5 mCi) in a volume of 0.3±0.5 ml, single subcostal injection at both sides SLN: 50±80 MBq (1.3±2.2 mCi) in a volume of 0.1± 0.5 ml, multiple subdermal injections (peritumoral) Guidelines for SLN detection should be followed (Cox et al. 1998) Gastroesophageal reflux: 20 MBq (0.5 mCi) of 99mTc-(Re, Sn)-sulfide nanocolloid in a suitable liquid according to local practice 40 MBq (1 mCi) maximum recommended activity Pediatric Dose. The amount of radioactivity for infants and children administered for lymphoscintigraphy is based on body weight, using the scaling factors given in Appendix 1 (Table A1.2). The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
Additional Information 99m
Tc-(Re, Sn)-sulfide colloid is not used for intravenous injection. A comparison with Tc-albumin nanocolloid showed considerable residual radioactivity in blood; approximately 11% were measured 3 h after the intravenous injection (De Schrijver et al. 1987). The stability of colloids is affected by electrolytes, thus 99mTc-(Re, Sn)-sulfide colloid should not be injected together with other drugs or components. Interstitial injection of a hypertonic colloidal solution may be associated with pain at the injection site. Therefore, 99mTc-(Re)-sulfide nanocolloid should be injected slowly. 99m
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
99m Tc-(Sn)-sulfide nanocolloid is supplied as an iso-osmolar solution, warranting a painless subcutaneous injection. For interstitial injection 99mTc-(Re, Sn)-sulfide nanocolloid must be applied in a small volume not exceeding 0.5 ml. To ensure high specific activity, labeling should be performed with a small volume of 99mTc eluate (£ 2 ml) and not less than 370 MBq (10 mCi). The use of local anesthetic agents or hyaluronidase prior to administering the labeled preparation have been shown to negatively affect lymphatic uptake. Iodinated contrast media used in lymphangiography may interfere with lymphatic imaging with 99mTc-(Re, Sn)-sulfide nanocolloid.
Quality Control Radiochemical Purity. 99mTc-(Re, Sn)-sulfide nanocolloid is not described in the European Pharmacopeia. Paper chromatography on Whatman 1 paper is recommended by the manufacturer, using methyl ethyl ketone (MEK) as solvent. Free 99mTc-sodium pertechnetate is measured at an Rf of 1.0 and 99mTc-(Re, Sn)-sulfide nanocolloid is identified at the origin. The radiochemical purity of 99mTc-(Re, Sn)-sulfide nanocolloid should not be less than 95%. The analysis of radiocolloids is based on the determination of free 99mTc-Na-pertechnetate, since colloidal activity remains at the start. Hydrolized 99mTc activity cannot be distinguished from the 99mTc-(Re, Sn)-sulfide nanocolloid. Recommended Methods Paper chromatography Stationary phase: Solvent: Developing time:
Whatman No. 1 paper, 2 ´ 9.5 cm Methyl ethyl ketone (MEK) 5 min
Rf values:
99m
Tc-(Re, Sn)-sulfide, nanocolloid: Tc reduced, hydrolized: 99m Tc-pertechnetate: 99m
0.0±0.1 (>95%) 0.0±0.1 0.9±1.0
Thin-layer chromatography on Gelman silica gel fiberglass sheets using acetone as solvent has been recommended for the identification of 99mTc-(Re)-sulfide microcolloid at the origin, and free 99mTc-pertechnetate at the solvent front (Rf = 1.0). This method is also recommended for the analysis of the nanocolloids. Quantification of labeled components Each chromatogram is measured (TLC linear analyzer or gamma counter) and the regional radioactivities are expressed as a percentage of the total recovered counts: 99m
Tc-(Re, Sn)-sulfide nanocolloid (%) = 100 ± F
where F (%) = 99mTc-Na-pertechnetate (free).
227
228
12.3
99m
Tc-Labeled Colloids
Results of analysis (12 samples) Results were obtained using thin-layer chromatography and acetone as solvent. Labeling and stability
15 min (%)
3 h (%)
99m
98.5 Ô 0.67 1.4 Ô 0.61
96.3 Ô 0.97 3.6 Ô 1.07
Tc-(Re, Sn)-sulfide nanocolloid Tc-Na-pertechnetate
99m
Pharmacokinetic Data After subcutaneous injection into the interdigital spaces of the hands or feet, 99mTc(Re, Sn)-sulfide nanocolloid is transported with the interstitial liquid through the lymphatic capillaries into the lymph ducts, and is almost quantitatively retained by the regional lymph nodes (Mostbeck et al. 1984). Release of the colloid from the lymph nodes is slow and increasing with movement of the extremities. After 15 min of slow walking, 6±15% of the injected radioactivity has been measured in the regional lymph nodes (Mostbeck et al. 1984). Accumulation of the colloid in the liver is negligible. Following the subcostal injection at both sides of the xyphoid (2±2.5 cm under the xyphoid) into the musculus rectus abdominalis, 99mTc-(Re, Sn)-sulfide nanocolloid is transported through the parasternal lymphatics into mediastinal and diaphragmal lymph nodes. The maximal accumulation is reached 3 h after injection (Ege 1983). Drainage from the interstitial injection site was observed between 1 and 35% in 24 h (Ege 1976). Basic concepts for quantitative lymphoscintigraphy were derived from experimental studies in rabbits by correlating the uptake of different radiocolloids in the parasternal lymph nodes with measurements of the particle size (Strand and Persson 1979). For colloidal gold (Au-198) with a well defined particle diameter of approximately 5 nm, highest uptake in regional lymph nodes was recorded. 99mTc-(Sb)-sulfide colloid (Sb2S3), with colloidal particles between 5 and 15 nm, showed less uptake (approximately 60%), yet the highest uptake of all 99mTc-colloids that were evaluated. Larger particles cannot pass through the lymphatic capillary pores and are trapped in the interstitial fluid. Thus 99mTc-tin colloid, 99mTc-phytate, and 99mTc-sulfur colloid remain primarily at the injection site and show little lymphatic migration (Strand and Persson 1979). 99m Tc-(Re, Sn)-sulfide nanocolloids show optimal physical characteristics (40± 80 nm) for reliable visualization of anatomic lymph nodes. Subdermal, peritumoral injection of 99mTc-(Re, Sn)-sulfide nanocolloid is used for visualization of the lymphatic drainage of a primary tumor and for identification of the SLN (Alazraki et al. 1997; Keshtgar et al. 1999; Nitz and Heidenreich 1999).
Radiation Dose Calculations of the absorbed radiation dose after the subcutaneous administration of 99m Tc-(Re)-sulfide nanocolloid into the extremities are based on the assumption that approximately 5±15% of the radioactivity are distributed over 10±20 lymph nodes (Mostbeck et al. 1984). The highest radiation dose is thus delivered at the injection site. If 37 MBq (1 mCi) are injected into each foot, the radiation absorbed dose at the injec-
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
tion site has been calculated as 400±700 mGy, and 22±27 mGy for each lymph node (Mostbeck et al. 1984). The weight of a lymph node was assumed to be 5 g. Based on a model for the subcutaneous injection of 99mTc-(Sb)-sulfide colloid into the umbilical region, Bergquist et al. (1982) have calculated the radiation dose at the injection site assuming a tissue volume of 10 ml. Injection of 37 MBq (1 mCi) results in an average radiation dose of approximately 300 mGy at the injection site. The effective dose equivalent was determined as 0.005 mSv/MBq (Bergqvist et al. 1982). Based on this information, the effective dose in adults (70 kg) resulting from the subcutaneous injection of 185 MBq (5 mCi) of 99mTc-(Re, Sn)-sulfide colloid is approximately 1 mSv.
Storage and Stability Storage. The lyophilized kit is stored at 2±8 8C. Stability. The tion.
99m
Tc-(Re)-sulfide nanocolloid injection is stable for 4 h after prepara-
References Alazraki N, Eshima D, Eshima LA, Herda SC, Murray DR, Vansant JP, Taylor AT (1997) Lymphoscintigraphy, the sentinel node concept, and the intraoperative gamma probe in melanoma, breast cancer and other potential cancers. Semin Nucl Med 27:55±67 Bergqvist L, Strand SE, Hafstræm L, Jænsson P-E (1984) Lymphoscintigraphy in patients with malignant melanoma: a quantitative and qualitative evaluation of its usefulness. Eur J Nucl Med 9:129±135 Cox CE, Pendas S, Cox JM, Joseph E, Shons AR, Yeatman T, Ku NN, Lyman GH, Berman C, Haddad F, Reintgen DS (1998) Guidelines for sentinel lymph node detection. Ann Surg 227:645±653 De Schrijver M, Streule K, Senekowitsch R, Fridrich R (1987) Scintigraphy of inflammation with nanometer-sized colloidal tracers. Nucl Med Commun 8:895±908 Ege GN (1976) Internal mammary lymphoscintigraphy ± the rationale, technique, interpretation and clinical application: a review based on 848 cases. Radiology 118:101±107 Ege GN (1983) Lymphoscintigraphy ± techniques and applications in the management of breast carcinoma. Semin Nucl Med 13:26±34 Kaplan WD, Davis MA, Rose CM (1979) A comparison of two technetium-99m-labeled radiopharmaceuticals for lymphoscintigraphy. J Nucl Med 20:933±937 Kaplan WD, Piez CW, Gelman RS, Laffin SM, Rosenbaum EM, Jennings CA, McCormick CA, Harris JR, Henderson IC, Atkins HL (1985) Clinical comparison of two radiocolloids for internal mammary lymphoscintigraphy. J Nucl Med 26:1382±1385 Keshtgar MRS, Waddington WA, Lakhani SR, Ell PJ (1999) The sentinel node surgical oncology. Springer, Berlin Heidelberg New York, and Eur J Nucl Med 26:57±67 Larson SM, Nelp WB (1966) Radiopharmacology of a simplified technetium-99m-colloid preparation for photoscanning. J Nucl Med 7:817±826 Lofferer O, Mostbeck A, Partsch H (1974) Lymphtransportstærung beim dicken Bein ± Isotopenlymphographische Ergebnisse [in German]. Z. Hautkr. 49(14): 615±622 Mostbeck A, Kahn P, Partsch H (1984) Quantitative Lymphographie beim Lymphædem. In: Bollinger A, Partsch H (eds) Initiale Lymphstrombahn [in German]. Georg Thieme, Stuttgart, pp 116±122 Nagai K, Ito Y, Otsuka N, Muranaka A (1982) Deposition of small 99mTc-labeled colloids in bone marrow and lymph nodes. Eur J Nucl Med 7:66±70 Nitz DW P, Heidenreich P (eds) (1999) Sentinel-Lymphknoten In: Der Nuklearmediziner [in German]. Demeter, Munich
229
230
12.3
99m
Tc-Labeled Colloids
Patton DP, Garcia EN, Webber MM (1966) Simplified preparation of technetium-99m-sulfide colloid for liver scanning. Am J Roentgenol Radium Ther Nucl Med 97:880 Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radio-pharmaceutical formulation problems. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 268±289 Strand S-E, Persson BRR (1979) Quantitative lymphoscintigraphy I: basic concepts for optimal uptake of radiocolloids in the parasternal lymph nodes of rabbits. J Nucl Med 20:1038±1046
12.3.2.2
99m
Tc-Albumin Nanocolloid (Size Range: 10±80 nm)
I. Zolle Chemical names
Listed trade names
Human albumin nanocolloid
Solco Nanocoll
GE Healthcare
Albumin nanoaggregates Aggregated albumin (AA) 99m
Tc-HSA-nanocolloid
Kit components Human albumin nanocolloid
0.5 mg
Stannous chloride ´ 2 H2O
0.2 mg
Glucose anhydrous Dibasic sodium phosphate, anhydrous Sodium phytate, anhydrous Poloxamer 238
Preparation The kit contains the sterile, lyophilized, preformed colloid in a multidose vial. Labeling with 99mTc-pertechnetate is carried out under aseptic conditions by adding 1±5 ml of 99m Tc eluate (maximum 5.5 GBq: approximately 150 mCi). The reaction is allowed to proceed at room temperature for 10 min. 99mTc-HSA nanocolloid is a sterile, pyrogenfree, opalescent solution suitable for the intravenous or subcutaneous injection. The pH is 4.0±7.0 on pH paper.
Description of the Kit Preformed albumin nanocolloid is easily labeled with reduced technetium at room temperature. No heating or pH adjustment is required. Once formed, albumin nanocolloid is unaffected by time. More than 95% of the 99mTc-albumin nanocolloid show a size distribution between 10 and 80 nm (Chia 1986; Solco Nanocoll 1992).
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
99m Tc eluate used for labeling the preformed colloid should be obtained from a generator by daily elution in order to minimize 99Tc carrier and should preferably be in a small volume to avoid any interference of Al3+ ion (Ponto et al. 1987). The manufacturer recommends a minimum volume of 99mTc eluate, which is adjusted to the final volume with oxidant-free saline. Labeling with a small volume (< 1 ml) of 99mTc-pertechnetate is also required if the colloid is used for lymphoscintigraphy.
Clinical Applications Intravenous injection:
Bone marrow scintigraphy Scintigraphy of inflammation Subcutaneous (interstitial) injection: Lymphoscintigraphy Visualization of lymphatic flow and regional lymph nodes in the extremities and the trunk Subdermal or peritumoral injection: Sentinel lymph node (SLN) scintigraphy Bone marrow scintigraphy with nanocolloids is based on a high extraction efficiency in bone marrow by phagocytosis (approximately 15% of the injection dose [ID]) (Hotze et al. 1984; McAfee et al. 1982; Munz 1984 a; Nagai et al. 1982.). In areas where no phagocytes are present, no uptake is observed. This is the case in the fatty marrow, or where the phagocyte population has been replaced by other structures, such as metastatic growth. Enhanced phagocytic activity is causing increased colloid uptake. Defects in bone marrow distribution, nonuniform marrow distribution, or an expansion of active marrow into long bones has been diagnosed. Both, hot and cold lesions are visualized in the scintigram. Biodegradable HSA nanocolloids offer considerable advantages over inorganic colloids. Large quantities labeled with I-131 have been used to study the phagocytic capacity of the reticuloendothelial system (RES) in healthy man and in patients with certain infections (Iio et al. 1963; Wagner et al. 1963). Nanocolloids preferentially accumulate in inflammatory lesions associated with a number of conditions, i.e., osteomyelitis, osteitis, rheumatoid arthritis, arthrosis, joint prostheses, and wound healing, thus nanocolloid is clinically useful for detecting osteomyelitis and other bone or joint infections (De Schrijver et al. 1987; Froehlich 1985; Vorne et al. 1989). Lymphoscintigraphy is performed for the diagnosis of peripheral edema caused by recurring erysipel or by affected lymph nodes as a result of metastatic infiltration, lymphogranuloma, lymphosarcoma, damage as a result of radiation treatment, or other causes. Other indications include secondary edema caused by blockade of the lymphatic flow, and thrombosis (Lofferer et al. 1974; Mostbeck et al. 1984). Lymphatic drainage from a primary tumor was studied in patients with breast cancer (Ege 1983). Several colloidal preparations have been evaluated for lymphoscintigraphy (Kaplan et al. 1979; Strand and Persson 1979; Kaplan et al. 1985). SLN imaging can identify the first infected lymph node of a primary tumor before surgery. If the SLN is histologically tumor-free, no other lymph node will contain metastatic disease (Alazraki et al. 1997; Nitz and Heidenreich 1999).
231
232
12.3
99m
Tc-Labeled Colloids
Time of Examination Bone marrow scintigraphy: 30 min after the intravenous injection Inflammation imaging: Static imaging 30±60 min after the intravenous injection Lymphoscintigraphy: Dynamic imaging immediately after the injection Static imaging 30±60 min after subcutaneous injection SLN imaging: Sequential planar scintigraphy 5±10 min postinjection and 1±6 h postinjection (late images) Recommended Activities for Indications Bone marrow scintigraphy: 185±370 MBq (5±10 mCi), injected intravenously 400 MBq maximum recommended activity 1.5±7 lg nanocolloid/kg body weight Inflammation scintigraphy: 370±555 MBq (10-15 mCi), injected intravenously Lymphoscintigraphy of the extremities: 20±75 MBq (0.5±2 mCi) in a volume of 0.2± 0.3 ml, subcutaneous injection into the interdigital spaces of the hands or feet. For a better resorption and to reduce the radiation burden to the injection site, the total dose (£ 185 MBq; 5 mCi) may be divided between two and three injection sites. 40 MBq (1 mCi) maximum activity per injection site The volume of injection should not exceed 0.5 ml Parasternal lymphatics: 20 MBq (0.5 mCi) in a volume of 0.3±0.5 ml, single subcostal injection at both sides The manufacturer's instructions should be followed. SLN: 50±80 MBq (1.3±2.2 mCi) in a volume of 0.1± 0.5 ml, multiple subdermal injections (peritumoral) Guidelines for sentinel lymph node detection should be followed (Cox et al. 1998) Pediatric Dose. The amount of radioactivity for infants and children administered for bone marrow and inflammation imaging or lymphoscintigraphy is based on body weight, using the scaling factors given in Appendix 1 (Table A1.2). The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
Additional Information The use of 99mTc-albumin nanocolloid in patients with a history of hypersensitivity to human albumin is contraindicated. The stability of colloids is affected by electrolytes; thus, 99mTc-albumin nanocolloid should not be injected together with other drugs or components. The use of local anes-
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
thetic agents or hyaluronidase prior to administering the labeled preparation has been shown to negatively affect lymphatic uptake. Albumin aggregates in the size range £ 100 nm are obtained by heating a 1% solution of human serum albumin (HSA) in alkaline medium (pH 10.0) while shaking (Iio et al. 1963). Controlling the pH, temperature, agitation rate, and optical density can assure a high degree of uniformity in size. Albumin nanocolloid is less affected by the concentration of Al3+ ion in the generator eluate than inorganic colloids. A reaction volume containing 1 lg Al3+ ion per milliliter had no effect; 2 lg/ml showed an increase in the particle diameter (80±100 nm) from 1±23% (Chia 1986; Haney 1971). For interstitial injection 99mTc-albumin nanocolloid must be applied in a small volume not exceeding 0.5 ml. To ensure high specific activity, labeling should be performed with a small volume of 99mTc eluate (£ 2 ml) and not less than 370 MBq (10 mCi). Interstitial injection of a hypertonic colloidal solution may be associated with pain at the injection site. Therefore, 99mTc-albumin nanocolloid should be injected slowly. Iodinated contrast media used in lymphangiography may interfere with lymphatic imaging with 99mTc-albumin nanocolloid.
Quality Control Radiochemical Purity. 99mTc-albumin nanocolloid is not described in the European Pharmacopeia. Paper chromatography using Whatman 31 ET paper and saline as solvent is recommended by the manufacturer. Free 99mTc-sodium pertechnetate is measured at an Rf of 0.75 and 99mTc-albumin nanocolloid is identified at the origin. The radiochemical purity of 99mTc-albumin nanocolloid should not be less than 95%. The analysis of radiocolloids is based on the determination of free 99mTc-Na-pertechnetate, since colloidal activity remains at the start. Hydrolized 99mTc activity cannot be distinguished from the 99mTc-HSA nanocolloid. Recommended Methods Thin layer chromatography on Gelman silica gel fiberglass sheets using acetone as solvent has been in clinical use for the analysis of 99mTc-(Re)-sulfide microcolloid and is also recommended for 99mTc-nanocolloids. Thin-layer chromatography Stationary phase: Solvent: Developing time:
Gelman ITLC-SG (fiberglass), 2 ´ 9.5 cm Acetone (or MEK) 5 min
Rf values:
99m
Tc-HSA nanocolloid: Tc reduced, hydrolized: Tc-pertechnetate:
99m 99m
0.0±0.1 (>95%) 0.0±0.1 0.9±1.0
Quantification of labeled components. Each chromatogram is measured (TLC linear analyzer or gamma counter), and the regional radioactivities are expressed as a percentage of the total recovered counts:
233
234
12.3 99m
99m
Tc-Labeled Colloids
Tc-HSA nanocolloid (%) = 100 ± F
where F (%) = 99mTc-Na-pertechnetate (free). Results of analysis (12 samples) Results were obtained using thin-layer chromatography and acetone as solvent. Labeling and stability
15 min (%)
3 h (%)
99m
96.7 Ô 0.15 3.3 Ô 0.50
96.3 Ô 0.16 3.7 Ô 0.40
Tc-HSA nanocolloid Tc-Na-pertechnetate
99m
Pharmacokinetic Data 99m
Tc-albumin nanocolloid is removed from the circulation by phagocytosis. More than 95% of the intravenously injected nanocolloid is accumulated in the liver, spleen, and bone marrow 15 min after administration (Chia 1986; Iio et al. 1963). Nanocolloids show high accumulation in bone marrow (10±15%) (Hotze et al. 1984; McAfee et al. 1982). Plasma clearance of colloidal particles is related to size; nanocolloids are normally cleared with a half-time of 2.6 min (Iio et al. 1963). Ten minutes after the intravenous injection, 10% of the injected dose was measured in blood (2.5% at 60 min), showing a constant decrease of radioactivity. In comparison, 99mTc-albumin microcolloid (0.2± 1.0 lm) showed approximately 1.6% of the injected dose at 10 min (Chia 1986). The maximal rate of phagocytosis of aggregated albumin (AA) in man was determined as 1.07 mg per minute per kilogram of body weight (Iio et al. 1963). An increase of extrahepatic accumulation of nanocolloid in the bone marrow is seen with hyperplastic bone marrow and with certain hematological disorders (polycytemia, leukemia) (Hæfer et al. 1964). In patients with malignant disease, bone marrow scintigraphy may offer early detection of bone marrow infiltration (Hotze et al. 1984; Munz 1984 b). After subcutaneous injection into the interdigital spaces of the hands or feet, nanocolloid is transported with the interstitial liquid through the lymphatic capillaries into the lymph ducts and taken up almost quantitatively by the regional lymph nodes. Drainage from the interstitial injection site was observed between 1 and 35% in 24 h (Ege 1976). Release of the colloid from the lymph nodes is slow and increasing with movement of the extremities. After 15 min of slow walking, 6±15% of the injected radioactivity has been measured in the regional lymph nodes (Mostbeck et al. 1984). Accumulation of the nanocolloid in the liver is negligible. Approximately 80% of the nanocolloid is transported by the lymphatic system (Saha 1987). After the subcostal injection at both sides of the xyphoid (2±2.5 cm under the xyphoid) into the musculus rectus abdominalis, 99mTc-albumin nanocolloid is transported through the parasternal lymphatics into mediastinal and diaphragmal lymph nodes. The maximal accumulation is reached 3 h after injection (Ege 1983). Subdermal, peritumoral injection of 99mTc-albumin nanocolloid is used for visualization of the lymphatic drainage of a primary tumor and for identification of the sentinel lymph node (Alazraki et al. 1997; Cox et al. 1998).
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Data on the acute toxicity of intravenously or subcutaneously injected 99mTc-albumin nanocolloid have not been reported. Repeated injections of high doses of colloidal albumin aggregates (5 mg/kg) over a 2-month period have been well tolerated in three subjects, showing no effect on the clearance rate when compared with control subjects (Iio et al. 1963). Subcutaneous injection of small doses (0.02 mg/kg) as well as a saturation dose of 4 mg/kg showed no evidence of hypersensitivity.
Radiation Dose After intravenous injection, the liver, spleen, and red bone marrow are the most exposed organs. The effective (whole body) dose equivalent is 0.014 mSv/MBq (International Commission on Radiological Protection 1987). The effective dose in adults (70 kg) resulting from 370 MBq (10 mCi) of 99mTc-albumin nanocolloid is 5.2 mSv. The dose to liver and spleen after intravenous injection of 185 MBq (5 mCi) is 13.7 and 14.2 mGy, respectively. The dose to the bone marrow after intravenous injection of 370 MBq (10 mCi) is 5.5 mGy. The effective dose equivalent (per ICRP 62) has been replaced by the quantity effective dose. Values per unit administered activity were published in Addendum 1 (International Commission on Radiological Protection 1991). Values calculated accordingly are slightly lower than the effective whole body dose presented here. Calculations of the absorbed radiation dose following the subcutaneous administration of 99mTc-albumin nanocolloid into the extremities are based on the assumption that approximately 5±15% of the radioactivity is distributed over 10±20 lymph nodes (Mostbeck et al. 1984). The highest radiation dose is thus delivered at the injection site. If 37 MBq (1 mCi) are injected into each foot, the radiation absorbed dose at the injection site has been calculated as 400±700 mGy, and 22±27 mGy for each lymph node. The weight of a lymph node was assumed to be 5 g (Mostbeck et al. 1984).
Storage and Stability Storage. The lyophilized kit is stored at 2±8 8C. Stability. The
99m
Tc-albumin nanocolloid injection is stable for 6 h after preparation.
References Alazraki N, Eshima D, Eshima LA, Herda SC, Murray DR, Vansant JP, Taylor AT (1997) Lymphoscintigraphy, the sentinel node concept, and the intraoperative gamma probe in melanoma, breast cancer and other potential cancers. Semin Nucl Med 27:55±67 Chia HL (1986) Particulate radiopharmaceuticals in nuclear medicine. In: Cox PH (ed) Radiopharmacy and Radiopharmacology yearbook II. Grune and Stratton, New York Cox CE, Pendas S, Cox JM, Joseph E, Shons AR, Yeatman T, Ku NN, Lyman GH, Berman C, Haddad F, Reintgen DS (1998) Guidelines for sentinel lymph node detection. Ann Surg 227:645±653 De Schrijver M, Streule K, Senekowitsch R, Fridrich R (1987) Scintigraphy of inflammation with nanometer-sized colloidal tracers. Nucl Med Commun 8:895±908
235
236
12.3
99m
Tc-Labeled Colloids
Ege GN (1976) Internal mammary lymphoscintigraphy ± the rationale, technique, interpretation and clinical application: a review based on 848 cases. Radiology 118:101±107 Ege GN (1983) Lymphoscintigraphy ± techniques and applications in the management of breast carcinoma. Semin Nucl Med 13:26±34 Froehlich JW (ed) (1985) Nuclear medicine in inflammatory diseases. In: Nuclear medicine annual. Raven, New York, pp 23±72 Haney TA, Ascanio I, Gigliotti JA, Gusmano EA, Bruno GA (1971) Physical and biological properties of a 99mTc-sulfur colloid preparation containing disodium edetate. J Nucl Med 12:64±68 Hæfer R, Ogris E, Pfeiffer G (1964) Kolloidspeicherung im Knochenmark bei Bluterkrankungen [in German]. Wien Z Inn Med 45:330±335 Hotze A, Mahlstedt J, Wolf F (1984) Knochenmarkszintigraphie: Methode, Indikationen, Ergebnisse [in German]. Giebeler, Darmstadt Iio M, Wagner HN Jr, Scheffel U, Jabbour B (1963) Studies of the reticuloendothelial system (RES). I. Measurement of the phagocytic capacity of the RES in man and dog. J Clin Invest 42:417± 426 International Commission on Radiological Protection (1987) Technetium-labeled colloids. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol. 18, no. 1±4. Pergamon, Oxford, pp 179±183 International Commission on Radiological Protection (1991) ICRP Publication 62. In: Annals of the ICRP, radiological protection in biomedical research, vol. 22, no. 3. Pergamon, Oxford, pp 25±28 Kaplan WD, Davis MA, Rose CM (1979) A comparison of two technetium-99m-labeled radiopharmaceuticals for lymphoscintigraphy. J Nucl Med 20:933±937 Kaplan WD, Piez CW, Gelman RS, Laffin SM, Rosenbaum EM, Jennings CA, McCormick CA, Harris JR, Henderson IC, Atkins HL (1985) Clinical comparison of two radiocolloids for internal mammary lymphoscintigraphy. J Nucl Med 26:1382±1385 Lofferer O, Mostbeck A, Partsch H (1974) Lymphtransportstærung beim dicken Bein ± Isotopenlymphographische Ergebnisse. Z Hautkr 49:615±622 McAfee JG, Subramanian G, Aburano T, Thomas FD, Fernandes P, Gagne G, Lyons B, Zapf-Longo C (1982) A new formulation of Tc-99m minimicro-aggregated albumin for marrow imaging: comparison with other colloids, In-111 and Fe-59. J Nucl Med 23:21±28 Mostbeck A, Kahn P, Partsch H (1984) Quantitative Lymphographie beim Lymphædem. In: Bollinger A, Partsch H (eds) Initiale Lymphstrombahn [in German]. Georg Thieme, Stuttgart, pp 116±122 Munz DL (1984 a) Knochenmarkszintigraphie: Grundlagen und klinische Ergebnisse [in German]. Der Nuklearmediziner 7:251±268 Munz DL (1984 b) The scintigraphic bone marrow status in adult man: a new classification. In: Schmidt HAE, Adam WE (eds) Nuklearmedizin. Darstellung von Metabolismen und OrganFunktionen. Schattauer, Stuttgart, p 640 Nagai K, Ito Y, Otsuka N, Muranaka A (1982) Deposition of small 99mTc-labeled colloids in bone marrow and lymph nodes. Eur J Nucl Med 7:66±70 Nitz DWP, Heidenreich P (1999) Sentinel-Lymphknoten. In: Der Nuklearmediziner. Demeter, Munich Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radio-pharmaceutical formulation problems. Hladik WB III, Saha GB, Study KT (eds) In: Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 268±289 Saha GB (1987) Normal biodistribution of diagnostic radiopharmaceuticals. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 6±7 SolcoNanocoll (1992) Product monograph of the kit for the preparation of Tc-99m nanocolloid, issued by Sorin Biomedica, Italy Strand S-E, Persson BRR (1979) Quantitative lymphoscintigraphy I: basic concepts for optimal uptake of radiocolloids in the parasternal lymph nodes of rabbits. J Nucl Med 20:1038±1046 Vorne M, Lantto T, Paakkinen S, Salo S, Soini I (1989) Clinical comparison of 99mTc-HM-PAO labeled leukocytes and 99mTc-nanocolloid in the detection of inflammation. Acta Radiol 30:633± 637 Wagner HN Jr, Iio M, Hornick RB (1963) Studies of the reticuloendothelial system (RES). II. Changes in the phagocytic capacity of the RES in patients with certain infections. J Clin Invest 42:427±434
Chapter 12 Monographs of
12.4
99m
Tc Pharmaceuticals
99m
12.4.1
Tc-Labeled Myocardial Perfusion Agents
99m
Tc-MIBI (Methoxyisobutyl Isonitrile)
F. Rakis and I. Zolle Chemical name
Chemical structure
2-Methoxy-isobutyl-isonitrile (MIBI) Tc(I)-Hexakis(2-methoxy-isobutylisonitrile) tetrafluroroborate Sestamibi (Ph. Eur., USP) Technetium Tc 99m sestamibi injection 99m 99m
Tc-MIBI Tc-sestamibi injection
99m
Kit components
Tc(I)-sestamibi complex
Commercial products
Cu(MIBI)4 ´ BF4
1.0 mg
Cardiolite
Bristol-Myers Squibb (BMS)
Tin(II)-chloride dihydrate
0.075 mg
Miraluma
DuPont Merck/BMS
L-Cysteine hydrochloride
1.0 mg
Cardiospect Rotop
Sodium citrate dihydrate
2.6 mg
Mannitol
20 mg
hydrate
Preparation The Cardiolite kit contains the lyophilized, sterile, pyrogen-free, inactive ingredients in a nitrogen atmosphere, ready for labeling with 99mTc-sodium pertechnetate (Council of Europe 2004). Labeling is performed according to the instructions given by the manufacturer (Bristol-Myers Squibb 2001). A volume of 1±3 ml of 99mTc-pertechnetate (0.925±5.55 GBq, resp. 25±150 mCi) is added aseptically to the reaction vial. Before removing the syringe, an equal volume of headspace to normalize the pressure in the vial should be withdrawn. The shielded vial should be agitated vigorously to dissolve the lyophilized material, and then is placed in a boiling water bath, which should be shielded, for 10 min. After heating, the vial is placed into the lead shield and cooled at room temperature for approximately 15 min. 99m Tc-sestamibi is a clear, colorless solution for intravenous injection, and the pH value is 5.3±5.9. Another diagnostic kit for the preparation of 99mTc-sestamibi is Miraluma, approved for breast imaging (Bristol-Myers Squibb 2001).
237
238
12.4
99m
Tc-Labeled Myocardial Perfusion Agents
Description of the Kit The Cardiolite kit contains 2-methoxy-isobutyl-isonitrile (MIBI) as a preformed copper(I) complex, Cu(MIBI)+4 ´ BF±4 [tetrakis (2-methoxy-isobutyl-isonitrile) Cu(I) tetrafluoroborate], which facilitates labeling by ligand exchange at elevated temperature. An alternate method of heating by exposure of the reaction vial in a microwave oven has been reported (Hung et al. 1991). Using a reaction volume of 3 ml, the time for heating was reduced to 10 s, obtaining consistently high labeling yields. Separate studies using 3 ml saline have shown that heating for 8 s produced a temperature of 98.7 Ô 0.3 8C. The Cardiolite kit contains no bacteriostatic agent. Only eluates from generators eluted within 24 h after the previous elution may be used for labeling, keeping the volume small (Van Duzee and Bugaj 1981).
Clinical Applications 99m
Tc(I)-sestamibi is used after intravenous injection: · Myocardial perfusion studies ± Diagnosis of ischemic heart disease ± Diagnosis and localization of myocardial infarction ± Assessment of global ventricular function (first pass technique for determination of ejection fraction and/or regional wall motion) · Breast imaging in patients with an abnormal mammogram · Parathyroid imaging in patients with hyperfunctioning adenoma Myocardial perfusion imaging with 99mTc-sestamibi has been evaluated by multicenter clinical studies (Wackers et al. 1989). The advantages of 99mTc-sestamibi have been demonstrated in normal subjects (Marcass et al. 1990), in patients with ischemic heart disease by comparison with thallium-201 (Maisey et al. 1990; Sporn et al. 1988; Villanueva-Meyer et al. 1990); and validated by single-photon emission computer tomography (SPECT) (Berman et al. 1993). Time of Examinations Rest and stress scintigraphy: 1±1.5 h after the intravenous injection Breast imaging: Planar imaging is begun 5±10 min postinjection Parathyroid imaging: 10±15 min postinjection Recommended Activities for Indications. The activity-range for intravenous administration in patients (70 kg) is: Diagnosis of reduced regional perfusion and myocardial infarction: 250±1,000 MBq (7±27 mCi) Assessment of global ventricular function: 600±800 MBq (16±25 mCi), injected as a bolus Miraluma breast imaging: 555±925 MBq (15±25 mCi) Parathyroid imaging: 185±740 MBq (5±20 mCi), injected as a bolus
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
The performance of myocardial scintigraphy requires a strict protocol. Usually, the first examination is performed with exercise or pharmacological stress, with the intravenous injection of 99mTc-sestamibi administered at the highest heart rate (250±370 MBq, resp. 7±10 mCi). The stress scintigram is performed 1±1.5 h after the injection. Three hours after the initial injection, a second dose of 99mTc-sestamibi (550± 750 MBq) (15±20 mCi) is administered intravenously to examine the patient at rest. The rest scintigram is performed 1±1.5 h after the injection. Two injections (stress and rest) are required in order to differentiate a transient (reversible) from a persistent perfusion defect, which is typical for ischemic heart disease (Borges-Neto et al. 1990; Bçll et al. 1996). For verification of a scar after myocardial infarction (nonreversible perfusion defect), one injection at rest (185±300 MBq, resp. 5± 8 mCi) may be sufficient. However, it is usually not possible to differentiate an acute myocardial infarction from ischemic defects, which are observed in patients with angina pectoris during chest pain (Tatum et al. 1997). Based on diagnostic reference levels for radiopharmaceuticals adopted by the European member states, the total activity administered on a single day should not exceed 1,000 MBq (27 mCi) in the case of the combined rest±exercise protocol and 600 MBq (16.2 mCi) in the case of the one-day protocol (European Commission 1999). A rather large variation in the recommendations from country to country has been reported (Hesse et al. 2005). Pediatric Dose. The amount of radioactivity for infants and children administered for myocardial scintigraphy is based on body weight, using the scaling factors given in Appendix 1, Table A1.2. The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
Additional Information Cardiac imaging. Patients should fast for at least 4 h prior to the study. It is recommended that patients take a light fatty meal or drink a glass of milk after each injection prior to SPECT imaging. This will promote rapid hepatobiliary clearance of 99mTcsestamibi, resulting in lower liver activity in the image. The heart-to-background ratio will increase with time; thus, the imaging time is the best compromise between heart count rate and surrounding organ uptake. Scintigraphy is performed 1±2 h after rest and stress injections. There is no evidence for significant changes in myocardial tracer concentration or redistribution. Either planar or tomographic imaging is performed for diagnosis of ischemic heart disease and myocardial infarction. Both may be performed electrocardiogram (ECG)-gated. For assessment of global ventricular function the same standard techniques and projections are used, as established for 99mTc first-pass ejection studies. Adequate hydration and frequent urination are necessary to reduce the radiation exposure of the bladder wall. Breast imaging. Another diagnostic purpose is the investigation of patients suspected of breast cancer, particularly patients with an abnormal mammogram or a palpable breast mass (Imbriaco et al. 2001; Palmedo et al. 1996 and 1998). Miraluma breast imaging is performed 10 min after the intravenous injection of 555 MBq (15 mCi) of 99mTc-sestamibi in the arm contralateral to the site of the breast
239
240
12.4
99m
Tc-Labeled Myocardial Perfusion Agents
abnormality. Then, planar images are obtained for 10 min in different positions according to the protocol. A malignant breast lesion is shown by increased uptake of the radiotracer. The detection of primary breast carcinoma may be carried out with either planar or SPECT acquisition. Parathyroid imaging is performed for localization and identification of hyperfunctioning adenoma (Coakley 1991) by two scintigraphic procedures: · Subtraction: Previously injected activity in thyroid gland is subtracted from the total neck image (99mTc-sestamibi + 123I- or 99mTc-thyroid image) (Wei et al. 1992). · Washout (planar or SPECT): Neck and thorax images are obtained at specified times (up to 4 h) after the injection of 99mTc-sestamibi (McBiles et al. 1995; Taillefer et al. 1992). In order to assure high quality of the injection solution, the radiochemical purity is determined before administration of 99mTc(I)-sestamibi to patients (Hung 1991).
Quality Control Radiochemical Purity. 99mTc-sestamibi is described in the European Pharmacopeia (Council of Europe 2005). Thin-layer chromatography using reverse-phase silica gel plates (octadecylsilyl-silica gel) and a mixture of acetonitrile, methanol, ammonium acetate, and tetrahydrofuran as solvent system is recommended for the separation of free 99m Tc-sodium pertechnetate (Rf = 0.9) and reduced, hydrolized 99mTc-activity (Rf = 0± 0.1). These impurities should not exceed 5% of the measured radioactivity. The radiochemical purity is analyzed prior to administration of 99mTc-sestamibi. If the labeling yield is less than 90%, the preparation should be discarded. Recommended Methods The commonly used method is thin-layer chromatography on aluminum oxide-coated plastic TLC plates and absolute ethanol as solvent. Free 99mTc-sodium pertechnetate and reduced, hydrolized 99mTc-activity remain at the start. 99mTc-sestamibi is measured at an Rf of 0.9, moving with the solvent front. The radiochemical purity of 99mTc-sestamibi should not be less than 94%. Thin-layer chromatography Stationary phase: Solvent: Developing time:
Baker-flex Alox 1B-F (precut to 2.5 ´ 7.5 cm) Ethanol (99.8%) 10 min
Rf values:
99m
Tc reduced, hydrolized: Tc-pertechnetate: Tc-MIBI complex:
99m
99m
0.0±0.1 0.0±0.1 0.9±1.0 (>94%)
Procedure: · Pour enough ethanol into the TLC tank (beaker) to have a depth of 3±4 mm of solvent. · Cover the tank (beaker) with parafilm and allow it to equilibrate for approximately 10 min. · Dry the plates at 100 8C for 1 h and store in a desiccator. Remove predried plate from the desiccator just prior to use.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
· Apply 1 drop of ethanol (95%), using a 1-ml syringe with a 22±26 gauge needle onto the aluminum oxide TLC plate, 1.5 cm from the bottom. Do not allow the spot to dry. · Add two drops of 99mTc-MIBI injection solution side by side on top of the ethanol spot. Return the plate to a desiccator and allow the sample to dry (typically, 15 min). · Develop the plate in the covered TLC tank in ethanol (99.8%) for a distance of 5.0 cm from the point of application. · Cut the TLC plate 4.0 cm from the bottom and measure the 99mTc activity of each piece in the dose calibrator. Calculate the percent radiochemical purity as: 99m
Tc-sestamibi
%
Activity of upper piece 100 Activity of both pieces
The time required to complete the entire procedure is approximately 35 min. Results of analysis (12 samples) Results were obtained using TLC and ethanol as solvent. Labeling and stability
15 min (%)
99m
5.4 Ô 0.3 94.6 Ô 0.3
Tc-Na-pertechnetate Tc-sestamibi
99m
6 h (%) 5.6 Ô 0.3 94.4 Ô 0.3
Paper chromatography Another method, which is faster and offers a high separation of 99mTc-MIBI from impurities was introduced by Patel et al. (1995). Whatman 3MM paper strips are used and ethyl acetate as solvent. 99mTc-sestamibi moves with an Rf of 0.55±0.75, while 99m Tc-pertechnetate and reduced, hydrolized 99mTc-activity remain at the start. Stationary phase: Solvent: Developing time:
Whatman 3MM paper strips (cut to 0.5 ´ 6.0 cm) Ethyl acetate 3 min
Rf values:
99m
Tc reduced, hydrolized: 0.0±0.1 Tc-Na-pertechnetate: 0.0±0.1 99m Tc-MIBI, 0.5±0.8 (>94%) 99m
Quantification of labeled components. Each chromatogram is measured (TLC linear analyzer or gamma counter), and the regional radioactivities are expressed as a percentage of the total recovered counts: 99m
Tc-sestamibi (%) = 100 ± % (F + H)
where % (F + H) = 99mTc activity at origin. Solvent extraction A rapid and simple method to obtain information about the labeling yield of lipophilic 99m Tc-sestamibi has found wide acceptance in nuclear medicine. Several solvents (e.g.,
241
242
12.4
99m
Tc-Labeled Myocardial Perfusion Agents
ethyl acetate, chloroform, n-octanol) have been employed for extraction. Labeled impurities remain in the aqueous phase (saline). Procedure: · Add 0.1 ml of the 99mTc-sestamibi injection solution to a vial containing 3 ml of chloroform and 2.9 ml of saline. · Close the vial, mix with a Vortex for 10 s, and let the phases separate for 1 min. · Transfer the top layer (saline) to another vial and measure the activities in a dose calibrator. Lipophilic 99mTc-MIBI is in the chloroform fraction and the contaminants are in the saline layer. The radiochemical purity is given by: 99m
Tc-MIBI
%
Activity of chloroform fraction 100 Activity of both fractions
Results of analysis. The activity in the chloroform fraction should not be less than 90% within 6 h after labeling.
Pharmacokinetic Data Like thallous chloride [201T1+], the cationic technetium complex accumulates in the viable myocardial tissue proportional to blood flow. Studies using cultures of myocardial cells have shown that uptake is not dependent on the functional capability of the sodium/potassium pump (Maublant et al. 1988). Cationic membrane transport inhibitors did not affect 1-min 99mTc-MIBI uptake kinetics when cells were preincubated for 1 min in solutions containing saturating concentrations of quabain (100 lM), a sodium/potassium ATPase inhibitor (Piwnica-Worms et al. 1990). After the intravenous injection, 99mTc-sestamibi is distributed in the myocardium according to blood flow and diffusion. Myocardial extraction at rest is 65% (vs 85% Tl+). One-hour-postinjection myocardial uptake at rest is 1.2%; during stress, it is 1.4% (Wackers et al. 1989). The elimination from blood is fast: 3 min after the intravenous injection, 23% of the radioactivity is measured in blood, decreasing to 9% at 5 min, and 2.5% at 10 min. The effective half-life at rest of the fast early component is 2.18 min (2.13 min during exercise) (Wackers et al. 1989). Protein binding is low (less than 1%). Elimination of 99mTc-sestamibi from the myocardium is 27% in 3 h; the biological half-time of elimination is approximately 6 h at rest and during stress. No redistribution of 99mTc-sestamibi is observed (Wackers et al. 1989). The major metabolic pathway for clearance of 99mTc-sestamibi is the hepatobiliary tract. Activity from the gallbladder appears in the intestine within 1 h of injection. Twenty-nine percent of the injected dose is cleared unchanged through renal elimination in 24 h, and approximately 37% of the injected dose is cleared through the feces in 48 h (at rest) (Wackers et al. 1989). The elimination during 3 h from the liver is 76%; from the spleen, 67%; and from the lung, 49% (Wackers et al. 1989).
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
The mechanism of localization in various types of breast tissue (benign, inflammatory, malignant, fibrous) has not been established. Malignant breast lesions show the highest uptake of 99mTc-sestamibi (sensitivity: 79±96%, specificity: 80±94%). Preclinical safety. Acute intravenous toxicity studies were performed in mice, rats, and dogs. The lowest dose of the reconstituted Cardiolite kit that resulted in any deaths was 7 mg/kg (expressed as Cu(MIBI)4 ´ BF4 content) in female rats. This corresponds to 500 times the maximal human dose (MHD) of 0.014 mg/kg for adults (70 kg). Neither rats nor dogs exhibited treatment related effects at reconstituted Cardiolite kit doses of 0.42 mg/kg (30 times MHD) and 0.07 mg/kg (5 times MHD), respectively, for 28 days.
Radiation Dose The gallbladder wall, liver, spleen, and lung are the most exposed organs. The effective dose is 0.0085 mSv/MBq at rest and 0.0075 mSv/MBq after exercise (International Commission on Radiological Protection 1991). The values are calculated assuming a 3.5-h bladder voiding period. When two separate injections of 99mTc-sestamibi are administered, namely 250 MBq (7 mCi) (exercise) and 750 MBq (20 mCi) (at rest) the effective whole-body dose in patients (70 kg) is 8.25 mSv. The effective dose resulting from an administered radioactivity of 250 MBq (7 mCi) at rest (verification of a scar) is 2.12 mSv. The absorbed radiation dose to the gallbladder wall resulting from an intravenous injection of 750 MBq (20 mCi) of 99mTc-sestamibi corresponds to 29.3 mGy (at rest).
Storage and Stability Storage. Cardiolite (Miraluma) kits should be stored at 15±25 8C. Stability.
99m
Tc-sestamibi injection solution is stable for 6 h.
References Berman DS, Kiat H, Friedman JD, Wang FP, Van Train K, Matzev L, Maddahi J, Germano G (1993) Separate acquisitions rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation study. J Am Coll Cardiol 22:1455±1464 Borges-Neto S, Coleman RE, Jones RH (1990) Perfusion and function at rest and treadmill exercise using technetium-99m-sestamibi: comparison of one- and two-day protocols in normal volunteers. J Nucl Med 31:1128±1132 Bristol-Myers Squibb (2001) Product Information. Cardiolite Kit for the preparation of technetium Tc-99m sestamibi for injection. Bristol-Myers Squibb Medical Imaging, Billerica, Mass. Bçll U, Kleinhans E, Reske SN (1996) Herz-Kreislauf-System. In: Bçll U, Schicha H, Biersack H-J, Knapp WH, Reiners C, Schober O (eds) Nuklearmedizin [in German]. Georg Thieme, Stuttgart, pp 203±246 Coakley AJ (1991) Parathyroid localization ± how and when? Eur J Nucl Med 18:151±152 European Commission (1999) Radiation protection 109, guidance on diagnostic reference levels (DRLs) for medical exposures. Office for Official Publications of the European Communities, Luxembourg
243
244
12.4
99m
Tc-Labeled Myocardial Perfusion Agents
Council of Europe (2005) Technetium [99mTc] sestamibi injection solution, European pharmacopeia monograph 1926. Maisonneuve, Sainte-Ruffine Hesse B, Tågli K, Cuocolo A et al (2005) EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging 32:855±897 Hung JC, Wilson ME, Brown ML, Gibbons RJ (1991) Rapid preparation and quality control method for technetium-99m-2-methoxy isobutyl isonitrile (technetium-99m-sestamibi). J Nucl Med 32:2162±2168 Imbriaco M, Del Vecchio S, Riccardi A, Pace L, Di Salle F, Di Gennaro F, Salvatore M, Sodano A (2001) Scintimammography with 99mTc-MIBI versus dynamic MRI for non-invasive characterization of breast masses. Eur J Nucl Med 28:56±63 International Commission on Radiological Protection (1991) Technetium-labelled MIBI. In: Annals of the ICRP, radiological protection in biomedical research. ICRP Publication 62, vol. 22, no. 3, Pergamon, pp 21±24 Maisey MN, Lowry A, Bischof-Delaloye A, Fridrich R, Inglese E, Khalil M, van der Schoot J (1990) European multicenter comparison of thallium-201 and technetium-99m-methoxyisobutyl isonitrile in ischemic heart disease. Eur J Nucl Med 16:869±872 Marcass C, Marzullo P, Oarodi O, Sambuceti G, L'Abbate A (1990) A new method of noninvasive quantitation of segmental myocardial wall thickening using technetium-99m 2-methoxy-isobutyl-isonitrile scintigraphy: results in normal subjects. J Nucl Med 31:173±177 Maublant JC, Gachon P, Moins N (1988) Hexakis (2-methoxy isobutylisonitrile) technetium-99m and thallium-201 chloride: uptake and release in cultured myocardial cells. J Nucl Med 29:48± 54 McBiles M, Lambert AT, Cote MG, Kim SY (1995) Sestamibi parathyroid imaging. Sem Nucl Med 25:221±234 Palmedo H, Biersack HJ, Lastoria S, Maublant J, Prats E, Stegner HE, Bourgeois P, Hustinx R, Hilson AJW, Bischof-Delaloye A (1998) Scintimammography with technetium-99m methoxyisobutyl isonitrile: results of a prospective European multicenter trial. Eur J Nucl Med 25:375±385 Palmedo H, Grçnwald F, Bender H, Schomburg A, Mallmann P, Krebs D, Biersack HJ (1996) Scintimammography with technetium-99m methoxyisobutylisonitrile: comparison with mammography and magnetic resonance imaging. Eur J Nucl Med 23:940±946 Patel M, Sadek S, Jahan S, Owunwanne A (1995) A miniaturized rapid paper chromatographic procedure for quality control of technetium-99m sestamibi. Eur J Nucl Med 22:1416±1419 Piwnica-Worms D, Kronauge JF, Delmon L, Holman BL, Marsh JD, Jones AG (1990) Effect of metabolic inhibition on technetium-99m-MIBI kinetics in cultured chick myocardial cells. J Nucl Med 31:464±472 Sporn V, Perez Balino N, Holman BL, Sosa Liprandi A, Masoli O, Mitta A, Camin LL, Castiglia S, McKusick KA (1988) Simultaneous measurement of ventricular function and myocardial perfusion using the technetium-99m isonitriles. Clin Nucl Med 13:77±81 Taillefer R, Boucher Y, Potvin C, Lambert R (1992) Detection and localization of parathyroid adenomas in patients with hyperparathyroidism using a single radionuclide imaging procedure with technetium-99m-sestamibi (double-phase study). J Nucl Med 33:1801±1807 Tatum JL, Jesse RL, Kontos MC, Nicholson CS, Schmidt KL, Roberts CS, Ornato JP (1997) Comprehensive strategy for the evaluation and triage of the chest pain patient. Ann Emerg Med 29: 116±125 United States Pharmacopeial Convention (2005) Official Monographs: USP 28, technetium Tc 99m sestamibi injection. United States Pharmacopeia, p 1863 Van Duzee BF, Bugaj JE (1981) The effect of total technetium concentration on the performance of a skeletal imaging agent. Clin Nucl Med 6(Suppl):P148 Villanueva-Meyer J, Mena I, Narahara KA (1990) Simultaneous assessment of left ventricular wall motion and myocardial perfusion with technetium-99m-methoxyisobutyl isonitrile at stress and rest in patients with angina: comparison with thallium-201 SPECT. J Nucl Med 31:457±463 Wackers FJTh, Berman DS, Maddahi J, Watson DD, Beller GA, Strauss HW, Boucher CA, Picard M, Holman BL, Fridrich R, Inglese E, Delaloye B, Bischof-Delaloye A, Camin L, McKusick K (1989) Technetium-99m hexakis 2-methoxyisobutyl isonitrile: Human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging. J Nucl Med 30:301±311 Wei JP, Burke GJ, Mansberger AR Jr (1992) Prospective evaluation of the efficacy of technetium99m-sestamibi and iodine-123 radionuclide imaging of abnormal parathyroid glands. Surgery 112:1111±1117
Chapter 12 Monographs of
12.4.2
99m
Tc Pharmaceuticals
99m
Tc-Tetrofosmin
J. Imre and I. Zolle Chemical structure
Chemical name 1,2-bis[bis(2-ethoxyethyl)-phosphino]ethane Tetrofosmin (USP) Technetium Tc 99m tetrofosmin injection (USP) Tc(V) dioxo diphosphine complex 99m
Tc-tetrofosmin injection 99m
Kit components
Tc(V)-tetrofosmin complex
Commercial products
Tetrofosmin
0.23 mg
Stannous chloride dihydrate
0.03 mg
Disodium sulfosalicylate
0.32 mg
Sodium D-gluconate
1.0 mg
Myoview
GE Healthcare
Sodium hydrogen carbonate 1.8 mg
Preparation The Myoview kit contains the sterile, lyophilized components in a nitrogen atmosphere. Labeling with 99mTc-sodium pertechnetate is performed by adding aseptically 4±8 ml of 99m Tc activity to the vial, not exceeding 1.11 GBq/ml (30 mCi/ml). Before the syringe is removed from the vial, a volume of gas should be withdrawn from the space above the solution to normalize the pressure inside the vial. The shielded vial should be gently agitated to dissolve the lyophilized material, and allowed to react at room temperature for 15 min (Nycomed Amersham 1998). 99m Tc(V)-tetrofosmin is a clear, colorless solution for intravenous injection, the pH value is 7.5±9.0.
Description of the Kit The cationic Tc(V) dioxodiphosphine complex consists of a Tc-trans-oxo core having four phosphorus atoms of the bidentate diphosphine ligands arranged in a plane. A comparison with DMPE [1,2-bis(dimethylphosphino)ethane], originally introduced as the Tc(III) dichlorodiphosphine complex, may elucidate the effect of derivatization on complex structure and in vivo performance (Deutsch et al. 1981, 1989). The tetrofosmin ligand is characterized by four ether functional groups (Kelly et al. 1993).
245
246
12.4
99m
Tc-Labeled Myocardial Perfusion Agents
Studies of the rate of formation of the [99mTc(tetrofosmin)2O2]+ complex have indicated that complex formation depends on the ligand concentration and could also be enhanced by heating (Kelly et al. 1993). However, using the Myoview formulation, the Tc(V) dioxodiphosphine complex is formed rapidly at room temperature in high radiochemical purity at a ligand concentration lower than 30 lg/ml. High chemical purity of the generator eluate is a prerequisite to obtain high labeling yields. To assure optimal reaction conditions, the eluate should be fresh (not older than 6 h), preferably obtained from a generator eluted regularly every 24 h. An interval of more than 72 h from the last elution excludes any generator eluate from being suitable for labeling Myoview. The volume of 99mTc eluate should be at least 4 ml and not more than 8 ml. The activity concentration must not exceed 1.11 GBq/ml and should be diluted before addition, if necessary. The amount of 99mTc activity should not exceed 8.88 GBq (240 mCi) (Nycomed Amersham1998).
Clinical Applications 99m
Tc(V)-tetrofosmin is used for myocardial perfusion studies in patients with coronary artery disease: · Diagnosis of ischemic heart disease · Diagnosis of reduced regional perfusion and localization of myocardial infarction · Detection of perfusion defects in myocardium at rest 99m
Tc-tetrofosmin has been evaluated as a radiotracer for myocardial perfusion imaging (Higley et al. 1993; Jain et al. 1993). Stress±rest imaging was performed using 1-day and 2-day protocols (Sridhara et al. 1994). Planar and tomographic imaging has been correlated with thallium-201 and coronary angiography (Heo et al. 1994). Pharmacological stress perfusion imaging with single-photon emission computer tomography (SPECT) was used as an alternative to dynamic exercise in patients with coronary artery disease (Cuocolo et al. 1996) and evaluated in a multicenter clinical trial (He et al. 1997). Left ventricular volumes and ejection fraction have been calculated from quantitative electrocardiographic-gated 99mTc-tetrofosmin myocardial SPECT (Yoshioka et al. 1999). 99mTc-tetrofosmin imaging at rest has been compared with rest redistribution of thallium-201 for predicting functional recovery after revascularization (Matsunari et al. 1997). Time of Examinations. The rest and stress scintigraphy is performed 15±30 minutes after the intravenous injection (Higley et al. 1993). Recommended Activities for Indications. The activity range for intravenous administration in patients (70 kg) is: Diagnosis of reduced regional perfusion and myocardial infarction: 250±1,000 MBq (7±27 mCi) First injection at peak exercise: 250±370 MBq (7±10 mCi) Second injection at rest (4 h after the first injection): 550±750 MBq (15±20 mCi) Single injection at rest: 185±300 MBq (5±8 mCi)
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
The performance of myocardial scintigraphy requires a strict protocol (He et al. 1997; Jain et al. 1993; Sridhara et al. 1994) Usually, the first examination is performed with exercise or pharmacological stress, the intravenous injection of 99mTc-tetrofosmin is administered at the highest heart rate (250±350 MBq). The stress scintigram is performed 15 min after injection. Four hours after the initial injection, a second intravenous injection of 99mTc-tetrofosmin (550±750 MBq) is administered to examine the patient at rest. The rest scintigram is performed 30 min after injection. Two injections (stress and rest) are required in order to differentiate a transient (reversible) from a persistent perfusion defect, which is typical for ischemic heart disease (Jain et al. 1993; Sridhara et al. 1994). For verification of a scar after myocardial infarction (nonreversible perfusion defect), one injection at rest may be sufficient (Higley et al. 1993). However, it is usually not possible to differentiate an acute myocardial infarction from ischemic defects, which are observed in patients with angina pectoris during chest pain (Tatum et al. 1997). Based on diagnostic reference levels for radiopharmaceuticals adopted by the European member states, the total activity administered on a single day should not exceed 1,000 MBq in the case of the combined rest±exercise protocol and 600 MBq in the case of the 1-day protocol (European Commission 1999). A rather large variation in the recommendations from country to country has been reported (Hesse et al. 2005). Pediatric Dose. Myoview is not recommended for use in infants and children since data are not available for these age groups.
Additional Information Patients should fast overnight or have only a light breakfast prior to the study. Patients should drink sufficient water, and frequent bladder emptying should be encouraged in order to reduce the radiation exposure to the bladder wall. Since no redistribution of 99mTc-tetrofosmin is observed, separate injections are required for stress and rest scintigraphy. Planar or preferably SPECT imaging should begin no earlier than 15 min postinjection. No significant changes in myocardial concentration or redistribution of 99mTc-tetrofosmin have been observed; therefore, images may be acquired up to at least 4 h postinjection (Higley et al. 1993; Jain et al. 1993).
Quality Control Radiochemical Purity. 99mTc-Tetrofosmin is not described in the European Pharmacopeia. A rapid instant thin-layer chromatography (ITLC) procedure for determination of the radiochemical purity of 99mTc-tetrofosmin has been published (Van Hemert et al. 2001). Thin-layer chromatography using Gelman silica gel strips and an organic solvent is described in the United States Pharmacopeia (United States Pharmacopeial Convention 2000) and is recommended by the manufacturer. Free 99mTc-pertechnetate moves with
247
248
12.4
99m
Tc-Labeled Myocardial Perfusion Agents
the solvent front. Reduced, hydrolized 99mTc activity and any hydrophilic complexes remain at the start. 99mTc-tetrofosmin is measured at an Rf of 0.4±0.7. The radiochemical purity of 99mTc-tetrofosmin should not be less than 90%. The radiochemical purity is analyzed prior to administration of 99mTc-tetrofosmin. If the labeling yield is less than 90%, the preparation should be discarded. Method Recommended by the Manufacturer Thin-layer chromatography Stationary phase: Solvent:
Gelman ITLC-SG strips (2 ´ 20 cm) Acetone-dichloromethane, 35 : 65 (v/v) Developing time: 20 min
Rf values:
99m
Tc-reduced, hydrolized; hydrophilic complexes: 0.0±0.1 Tc-tetrofosmin complex (lipophilic): 0.4±0.7 (> 90%) 99m Tc-pertechnetate: 0.9±1.0 99m
Procedure: · Pour enough solvent into the TLC tank (beaker) to have a depth of 1 cm. · Cover the tank (beaker) with a lid and allow it to equilibrate for approximately 10 min. · Mark the origin on the ITLC-SG strip with a pencil line 3 cm from the bottom. · Apply 10±20 ll of sample at the origin of the silica gel strip. Do not allow the spot to dry. · Place the strip into the chromatography tank and cover it immediately. Ensure that the strip is not adhering to the walls of the tank. · Develop the plate in the covered TLC tank for a distance of 15 cm from the point of application. · Cut the TLC strip at 3 cm and at 12 cm from the origin and measure the 99mTc activity of each piece in the dose calibrator. Calculate the percent radiochemical purity as: 99m
Tc-tetrofosmin
%
Activity of center piece 100 Total activity of all three pieces
Quantification of labeled components. Each chromatogram is measured (TLC linear analyzer or gamma counter), and the regional radioactivities are expressed as a percentage of the total recovered counts: 99m
Tc-tetrofosmin
% 100
%
F H
where F (%) = free 99mTc-pertechnetate, and H (%) = hydrolized drophilic complexes.
99m
Tc activity and hy-
Results of analysis (12 samples) Labeling and stability
15 min (%)
8 h (%)
99m
97.5 Ô 0.40 2.1 Ô 0.13 0.3 Ô 0.08
96.6 Ô 0.29 2.5 Ô 0.19 0.8 Ô 0.31
Tc-tetrofosmin complex Tc-hydrolized and hydrophilic complexes 99m Tc-Na-pertechnetate 99m
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Pharmacokinetic Data The lipophilic 99mTc-tetrofosmin complex accumulates in viable myocardial tissue proportional to blood flow. Uptake is due to diffusion; retention is based on viable myocytes (Platts et al. 1995; Takahashi et al. 1996). After the intravenous injection, the myocardial extraction of 99mTc-tetrofosmin at rest is 65% (Tl+ 85%). Five minutes postinjection, myocardial uptake is 1.2%; during stress, 1.3%. The myocardial concentration of 99mTc-tetrofosmin remains unchanged up to at least 4 h postinjection (Higley et al. 1993; Jain et al. 1993). The elimination from blood is fast; 10 min after the intravenous injection less than 5% of the radioactivity are measured in blood, corresponding to 3.5% in the plasma (Higley et al. 1993). The major metabolic pathway for clearance of 99mTc-tetrofosmin is the hepatobiliary tract. Activity in the gallbladder reaches a maximum (10% of the injected dose) within 2 h of injection, falling to below 1% at 24 h (Higley et al. 1993). Accumulation in the liver is 4.9±10.6% of the injected radioactivity; this value falls to 1.6% within 2 h, and after 8 h elimination is complete. Following exercise uptake is reduced to half the value with enhanced sequestration in skeletal muscle (Higley et al. 1993). Initially, the lung show 0.7±3.0% uptake; elimination of radioactivity is fast, showing only traces of activity 4 h postinjection. Urinary excretion is 39% in 48 h. Approximately 34% of the injected dose is cleared through the feces in 48 h (Higley et al. 1993). Preclinical safety. Acute intravenous toxicity studies were performed in rats and rabbits, using up to 1,500 times the maximum single human dose. Repeat dose toxicity was assessed in rats and rabbits at 0, 10, 100, and 1,000 times the maximum human dose daily for 14 days. No toxicologically significant findings were made on single-dose administration of 1,500 times the maximum equivalent human dose, or on 14-day repeat dose studies at a level of 100 times the maximum human dose. No mortalities have occurred (Kelly et al. 1993). No significant mutagenic potential was seen in any of the tests used.
Radiation Dose The gallbladder wall, intestinal tract, kidneys, bladder wall, the salivary glands, and the thyroid, are most exposed organs. Calculations of the effective dose were published by Higley et al. (1993), presenting effective dose values of 0.0089 mSv/MBq at rest and 0.0071 mSv/MBq after exercise, comparable with the effective dose values for technetium-MIBI (International Commission on Radiological Protection 1991). The values are calculated assuming a 3.5-h bladder voiding period. When two separate injections of 99mTc-tetrofosmin are administered, namely 250 MBq (7 mCi) (exercise) and 750 MBq (20 mCi) (at rest), the effective whole-body dose in patients (70 kg) is 8.45 mSv. The effective dose resulting from an administered radioactivity of 250 MBq (7 mCi) at rest (verification of a scar) is 2.2 mSv.
249
250
12.4
99m
Tc-Labeled Myocardial Perfusion Agents
The absorbed radiation dose to the gallbladder wall resulting from an intravenous injection of 750 MBq (20 mCi) of 99mTc-tetrofosmin is corresponding to 29.3 mGy (at rest).
Storage and Stability Storage. The Myoview kit is stored at 2±8 8C. Stability. 99mTc-tetrofosmin injection solution is stable for 8 h. It should be kept at 2±8 8C.
References Cuocolo A, Nicolai E, Pace L, Nappi A, Sullo P, Cardei S, Argenziano L, Ell PJ, Salvatore M (1996) Technetium-99m-labeled tetrofosmin myocardial tomography in patients with coronary artery disease: comparison between adenosine and dynamic exercise stress testing. J Nucl Cardiol 3:194±203 Deutsch E, Glavan KA, Sodd VJ, Nishiyama H, Ferguson DL, Lukes SJ (1981) Cationic Tc-99m complexes as potential myocardial imaging agents. J Nucl Med 22:897±907 Deutsch E, Ketring AR, Libson K, Vanderheyden J-L, Hirth WJ (1989) The Noah's ark experiment: species dependent biodistributions of cationic 99mTc complexes. Int J Rad Appl Instrum 16:191±232 European Commission (1999) Radiation protection 109, guidance on diagnostic reference levels (DRLs) for medical exposures. Office for Official Publications of the European Communities, Luxembourg He Z-X, Iskandrian AS, Gupta NC, Verani MS (1997) Assessing coronary artery disease with dipyridamole technetium-99m-tetrofosmin SPECT: a multicenter trial. J Nucl Med 38:44±48 Heo J, Cave V, Wasserleben V, Iskandrian AS (1994) Planar and tomographic imaging with technetium 99m-labeled tetrofosmin: correlation with thallium 201 and coronary angiography. J Nucl Cardiol 1:317±324 Hesse B, Tågli K, Cuocolo A et al (2005) EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging 32:855±897 Higley B, Smith FW, Smith T, Gemmell HG, Gupta PD, Gvozdanocic DV, Graham D, Hinge D, Davidson J, Lahiri A (1993) Technetium-99m-1,2-bis[bis(2-ethoxyethyl)phosphino]ethane: human biodistribution, dosimetry and safety of a new myocardial perfusion imaging agent. J Nucl Med 34:30±38 International Commission on Radiological Protection (1991) Technetium-labeled MIBI In: Annals of the ICRP, Radiological protection in biomedical research. ICRP publication 62, vol. 22, no. 3. Pergamon, Oxford, pp 21±24 Jain D, Wackers FJT, Mattera J, McMahon M, Sinusas AJ, Zaret BL (1993) Biokinetics of technetium-99m-tetrofosmin: myocardial perfusion imaging agent: implications for a one-day imaging protocol. J Nucl Med 34:1254±1259 Kelly JD, Forster AM, Higley B, Archer CM, Booker FS, Canning LR, Chiu KW, Edwards B, Gill HK, McPartlin M, Nagle KR, Latham IA, Pickett RD, Storey AE, Webbon PM (1993) Technetium-99m-tetrofosmin as a new radiopharmaceutical for myocardial perfusion imaging. J Nucl Med 34:222±227 Matsunari I, Fujino S, Taki J, Senma J, Aoyama T, Wakasugi T, Hirai J-I, Saga T, Yamamoto S, Tonami N (1997) Quantitative rest technetium-99m tetrofosmin imaging in predicting functional recovery after revascularization: comparison with rest-redistribution thallium-201. J. Am Coll Cardiol 29:1226±1233 Nycomed Amersham (1998) Product monograph for the Myoview kit for the preparation of technetium Tc-99m tetrofosmin for injection. Nycomed Amersham, Buckinghamshire Platts EA, North TL, Pickett RD, Kelly JD (1995) Mechanism of uptake of technetium-tetrofosmin. I: uptake into isolated adult rat ventricular myocytes and subcellular localization. J Nucl Cardiol 2:317±326
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Sridhara B, Sochor H, Rigo P, Braat SH, Itti R, Martinez-Duncker D, Cload P, Lahiri A (1994) Myocardial single-photon emission computed tomographic imaging with technetium-99m tetrofosmin: stress±rest imaging with same-day and separate-day rest imaging. J Nucl Cardiol 1:138± 143 Takahashi N, Reinhardt CP, Marcel R, Leppo JA (1996) Myocardial uptake of 99mTc-tetrofosmin, sestamibi, and 201Tl in a model of acute coronary reperfusion. Circulation 94:2605±2613 Tatum JL, Jesse RL, Kontos MC, Nicholson CS, Schmidt KL, Roberts CS, Ornato JP (1997) Comprehensive strategy for the evaluation and triage of the chest pain patient. Ann Emerg Med 29:116±125 United States Pharmacopeial Convention (2005) Official Monographs: USP 28, technetium Tc 99m tetrofosmin injection. United States Pharmacopeia (USP) 28±national formulary (NF) 23, p 1865 Van Hemert FJ, van Eck-Smit BLF, Schimmel KJM (2001) A rapid and stable ITLC procedure for the determination of the radiochemical purity of 99mTc-tetrofosmin. Nucl Med Commun 22:641±644 Yoshioka J, Hasegawa S, Yamaguchi H, Tokita N, Paul AK, Xiuli M (1999) Left ventricular volumes and ejection fraction calculated from quantitative electrocardiographic-gated 99mTc-tetrofosmin myocardial SPECT. J Nucl Med 40:1693±1698
12.5
99m
12.5.1
Tc-Labeled Brain Perfusion Agents
99m
Tc-HMPAO (Hexamethylpropylene Amine Oxime)
F. Rakis and I. Zolle Chemical structure
Chemical name 4,8-diaza-3,6,6,9-tetramethyl-undecane2,10-dione-bisoxime (HMPAO) D,L-Hexamethylpropylene amine oxime (D,L-HMPAO)
Exametazime (Ph. Eur., USP) Technetium 99mTc exametazime injection (Ph. Eur., USP) 99m
Tc(V)oxo-D,L-HMPAO complex
Kit components
99m
Tc(V)- D, L -HMPAO complex
Commercial products
Exametazime
0.5 mg
Ceretec
GE Healthcare
Tin(II)-chloride dihydrate
7.6 lg
Neurospect
Rotop
Sodium chloride
4.5 mg
251
252
12.5
99m
Tc-Labeled Brain Perfusion Agents
Preparation The Ceretec kit contains the lyophilized, sterile ingredients in a multidose vial. Labeling with 99mTc eluate is carried out under aseptic conditions by adding 5 ml of sterile sodium 99mTc-pertechnetate to the vial (0.37±1.11 GBq). The shielded vial should be gently inverted for 10 s to ensure complete dissolution of the lyophilisate. The reaction is allowed to proceed at room temperature for 5 min. 99m Tc-hexamethylpropylene amine oxime (HMPAO) is a sterile, pyrogen-free, clear, colorless solution suitable for intravenous injection. The resulting pH is between 9.0 and 9.8. In addition, each package consisting of five labeling units contains also five vials of methylene blue injection 1% USP (10 mg methylene blue USP in 1 ml water for injection), and five vials containing 0.003 M monobasic sodium phosphate USP and dibasic sodium phosphate USP in 4.5 ml of 0.9% sodium chloride injection USP. Each milliliter contains 0.276 mg monobasic sodium phosphate monohydrate, 0.142 mg dibasic sodium phosphate anhydrous, and 9 mg sodium chloride in water for injection for a sufficient amount. A mixture of methylene blue in phosphate buffer is used for stabilization of the 99mTc-HMPAO complex (Amersham Healthcare 1995).
Description of the Kit 99m
Tc-d,l-HMPAO complex is formed rapidly with reduced technetium at room temperature. The stannous tin content per vial should not decrease to less than 6 lg. Thus, high labeling is depending on maintaining tin in the reduced state. Any oxidant in the 99m Tc eluate should be avoided. Only eluates from generators eluted regularly within 24 h after the previous elution may be used for labeling (Amersham Healthcare 1995). Isotopic dilution is observed with higher concentrations of 99Tc in the first eluate of new generators or after weekends, reducing the labeling efficiency (Ponto et al. 1987). The formulation contains no antimicrobial preservative. 99m Tc-exametazime injection solution should be used within 60 min after labeling. In order to maintain high stability of the 99mTc-HMPAO complex for up to 6 h after preparation, the producer provides methylene blue injection USP 1% or alternatively, cobalt(II)-chloride aqueous solution (250 lg/2.5 ml, European Pharmacopeia [Ph. Eur.]) for stabilization. Stabilization of the 99mTc-HMPAO complex for intravenous use with methylene blue. Half a milliliter of methylene blue injection 1% USP should be withdrawn into a sterile syringe and injected into the 4.5-ml vial containing the buffer solution. Two milliliters of the methylene blue/phosphate buffer mixture should be gently swirled and withdrawn into a syringe for use as stabilizer. This mixture must be used within 30 min of preparation. Within 2 min after labeling, add 2.0 ml of the methylene blue/phosphate buffer mixture to the Ceretec vial (Amersham Healthcare 1995). The volume of stabilized Ceretec injection solution is 7.0 ml, and the resulting pH between 6.5 and 7.5. The 99mTc-HMPAO complex stabilized with methylene blue is stable for 4 h.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Stabilization of the 99mTc-HMPAO complex with cobalt(II)-chloride. Two milliliters of cobalt stabilizer solution (250 lg cobalt(II)-chloride ´ 6 H2O dissolved in 2.5 ml of water for injection) should be withdrawn with a 3-ml sterile syringe. Within 1±5 min after labeling, 2.0 ml of the stabilizer solution should be injected into the Ceretec vial, and the vial agitated for 10 sec. The volume of stabilized Ceretec injection solution is 7.0 ml, and the resulting pH between 5.0 nd 8.0. The 99mTc-HMPAO complex stabilized with cobalt(II)-chloride is stable for 6 h.
Clinical Applications Technetium-99m exametazime injection is indicated for brain scintigraphy for the diagnosis of perfusion abnormalities of regional cerebral blood flow (rCBF): · Detection of focal perfusion abnormalities · Diagnosis of acute cerebral infarction (stroke) when computer tomography (CT) is negative · Classification of defects of ischemic stroke · Diagnosis of cerebrovascular disease and differentiation of focal abnormalities in CBF typical in multi-infarct dementia and degenerative dementia The kinetic parameters of 99mTc-HMPAO retention in the human brain have been studied (Lassen et al. 1988), and measurements of CBF have been compared to 133Xe (Andersen et al. 1988). CBF was quantified using dynamic single-photon emission computer tomography (SPECT) (Murase et al. 1992). The role of SPECT with 99mTc-HMPAO in ischemic stroke has been evaluated (Heiss 1983; Podreka et al. 1987). Reflow hyperemia in subacute stroke has been described as ªluxury perfusionº (Lassen 1966) and was later explained by hyperfixation of 99mTc-HMPAO (Lassen and Sperling 1993). Increased regional blood flow in subacute stroke has been measured with 99mTc-HMPAO (Moretti et al. 1990). The effect of acetazolamide on CBF was reported in patients with severe internal carotid artery stenosis/occlusion (Asenbaum et al. 1995), and has been studied in primates (Dormehl et al. 1997). 99mTc-HMPAO SPECT was evaluated in patients with cerebrovascular disease by comparison with 18F-fluoromethane positron emission tomography (PET) (Heiss et al. 1990). A pattern of focal abnormalities in CBF was derived in patients with degenerative dementia (Holman et al. 1992). Time of Examination Dynamic imaging: Planar/tomographic imaging:
Right after intravenous injection up to 10 min postinjection 15 min up to 6 h postinjection
Recommended Activities for Indications Cerebral perfusion scintigraphy: 370±740 MBq (10±20 mCi), injected intravenously 500 MBq (13.5 mCi) maximum recommended activity (Administration of Radioactive Substances Advisory Committee 1993) The manufacturer's instructions should be followed.
253
254
12.5
99m
Tc-Labeled Brain Perfusion Agents
Pediatric Dose. The amount of radioactivity for infants and children administered for brain scintigraphy is based on body weight, using the scaling factors given in Appendix 1 (Table A1.4). The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
Additional Information The 99mTc eluate used for labeling should be obtained from a 99mTc-generator, which is eluted daily at a 24-h interval. When using the stabilizing protocol, generator eluates older than 30 min should not be used. Highest radiochemical purity is obtained with 99m Tc-pertechnetate right after elution. The lipophilic 99mTc-HMPAO complex is transformed by hydrolysis (in vitro) to the ªsecondaryº hydrophilic 99mTc-HMPAO complex, which cannot cross the blood±brain barrier (BBB) when injected. Since a high extraction fraction is essential for quantitation of CBF, high radiochemical purity of lipophilic 99mTc-HMPAO is required. The average value of lipophilic 99mTc-HMPAO has been reported as 83% (Lassen et al. 1988) and 80.8% (Murase et al. 1992), respectively. Care has been taken to minimize the time between the quality control measurements and administration of the 99mTc-HMPAO complex (Murase et al. 1992). Stabilization of the 99mTc-HMPAO complex with methylene blue/phosphate buffer or with cobalt(II)-chloride will extend in vitro stability up to 6 h after labeling. The patient should be asked to drink water frequently in order to stimulate excretion of radioactivity. The 99mTc-exametazime complex may be used for radiolabeling of leukocytes. In this case, stabilization with methylene blue/phosphate buffer should not be used. A generator eluate more than 2-h-old should not be used for complex formation.
Quality Control Radiochemical Purity. 99mTc-exametazime is included in the Ph. Eur. (Council of Europe 2005). Thin-layer chromatography on silica gel fiberglass plates using two solvent systems is described to determine the radiochemical purity of the injection solution. Free 99mTc-Na-pertechnetate (B) is determined in saline, the lipophilic 99mTc-HMPAO complex (D) is quantified indirectly by a subtraction method (Tab. 1). Previously, three solvent systems had been used, as recommended by the manufacturer. The labeled product must be tested before application in patients. The radiochemical purity of lipophilic 99mTc-exametazime should not be less than 80% (Ph. Eur.). Thin-layer chromatography. Aliquots are spotted and analyzed within 2 minutes after labelling, before stabilisation. The entire procedure of analysis takes approx. 15 minutes. · System I: Gelman ITLC silica gel fiberglass plates and 2-butanone (methyl ethyl ketone [MEK]) as solvent: Reduced, hydrolized 99mTc-technetium (C) and the secondary 99mTc-HMPAO complex (A) remain at the start (A+C); the lipophilic 99mTcHMPAO complex (D) and unbound 99mTc-Na-pertechnetate (B) are measured at the solvent front (B+D).
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
· System II: Gelman ITLC silica gel fiberglass plates and saline as solvent: Reduced, hydrolized 99mTc-technetium (C), the lipophilic and the secondary 99mTc-HMPAO complexes (A+D) remain at the start (A+C+D); unbound 99mTc-Na-pertechnetate (B) moves with the solvent front. Table 1. Thin-layer chromatography on silica gel fiberglass plates using two solvent systems System I (MEK)
Sum of reduced, hydrolized 99mTc activity and the secondary 99mTc-HMPAO complex at the start: Sum of lipophilic 99mTc-HMPAO complex and free 99m Tc-pertechnetate at the solvent front:
(A + C)
System II (Saline)
Free 99mTc-pertechnetate at the solvent front: 99m Tc activity at origin corresponding to:
(B) (A + C + D)
(B + D)
A, B, and C represent labeled impurities, D is the lipophilic 99mTc-HMPAO complex D (%) = 100±% (A + C + B) (Ph. Eur.) D (%) = % (A + C+D)±%(A+C) (USP)
Impurities (A+C) measured in solvent I (MEK) and free 99mTc-pertechnetate (B), quantified in system II at the solvent front are subtracted from the total recovered activity, which is assumed as 100%. Free 99mTc-pertechnetate (B) should not exceed 10% of the total radioactivity, the lipophilic 99mTc-HMPAO complex should not be less than 80% (Ph. Eur.). The difference between activity measured at the start (A+C+D) in solvent II (saline) minus activity measured at the start (A+C) in solvent I (MEK) corresponds to the percentage of the lipophilic 99mTc-HMPAO complex. Radioactivity measured at the solvent front (B) in system II indicates the amount of free 99mTc-pertechnetate (USP). The percentage of the lipophilic 99mTc-HMPAO complex is calculated according to the specifications described in the pharmacopeias (Tab. 1). Methods recommended by the manufacturer: Thin-layer chromatography on Gelman silica gel sheets and paper chromatography on Whatman 1 strips is recommended by the manufacturer, using three solvent systems for the analysis of the lipophilic 99mTc-HMPAO complex (D), the secondary hydrophilic complex (A), unbound 99mTc-Na-pertechnetate (B), and reduced, hydrolized 99mTc activity (C) (Tab. 2). Since reduced, hydrolized 99mTc activity is determined separately, each impurity is quantified. The radiochemical purity of lipophilic 99mTc-exametazime should not be less than 80% (USP 28). System I and II are identical with the methods recommended in the Ph. Eur. System III is based on paper chromatography using Whatman 1 paper strips and acetonitrile-water (1 : 1) as solvent. Reduced, hydrolized 99mTc-technetium (C) remains at the start; both 99mTc-HMPAO complexes (A+D) and unbound 99mTc-Na-pertechnetate (B) are measured at the solvent front (A+B+D).
255
256
12.5
99m
Tc-Labeled Brain Perfusion Agents
Table 2. Thin-layer chromatography and paper chromatography using three solvent systems (recommended for Ceretec) System I
Sum of reduced, hydrolized 99mTc activity and the secondary 99mTc-HMPAO complex at the origin
System II
Free
System III
Reduced, hydrolized
99m
Tc-pertechnetate at the solvent front
(A + C) (B)
99m
Tc-activity at the origin
(C)
D (%) = 100 ± % (A + B + C)
The added impurities % (A + B + C) are subtracted from the total recovered activity (100%) according to the recommended methods (Tab. 2). Lipophilic
99m
Tc-HMPAO complex (% D) = 100±%(A + B + C)
A = Secondary 99mTc-HMPAO complex B = 99mTc-pertechnetate C = Reduced, hydrolized 99mTc activity D = Lipophilic 99mTc-HMPAO complex Results of analysis (12 samples) Results were obtained using the analytical methods originally described for Ceretec (Amersham Healthcare 1995) outlined in Tab. 2. Labeling and stability
15 min (%)
1 h (%)
99m
90.1Ô1.06 4.5Ô0.90 2.9Ô0.51 2.4Ô0.47
85.6Ô1.23 6.5Ô1.79 3.9Ô0.62 4.0Ô1.42
Tc-HMPAO lipophilic complex (D) Tc-HMPAO secondary complex (A) 99m Tc-Na-pertechnetate (B) 99m Tc-reduced, hydrolized (C) 99m
Solvent extraction A more rapid method to obtain information about the labelling yield (percentage of lipophilic 99mTc-exametazime) has found wide acceptance in nuclear medicine (Ballinger et al. 1988). Several solvents (ethyl acetate, chloroform, n-octanol) have been employed for the extraction of the lipophilic 99mTc-HMPAO complex. Labelled impurities remain in the aqueous phase. Procedure: A sample of 0.1 ml of labeled Ceretec is added to a mixture of 3 ml of chloroform and 2.9 ml of saline. Close vial and mix well using a vortex mixer for 30 seconds. Let phases separate for 1 min, then transfer the top layer (saline) to another vial and measure both vials in a dose calibrator. The radiochemical purity of the lipophilic 99mTc-HMPAO complex is expressed by: 99m
Tc-HMPAO
%
Activity of chloroform fraction 100 Sum of activities in both fractions
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
A comparison of results obtained with both methods (ITLC and solvent extraction) indicates excellent correlation between both separation methods: ITLC separation (n = 12) Solvent extraction (n = 12)
87.0 Ô 2.0% 85.5 Ô 3.7%
Pharmacokinetic Data Neutral, lipophilic molecules with log P-values between 0.9 and 3.5 may cross the BBB by diffusion or active process, depending on the structural configuration (Holm et al. 1985; Troutner et al. 1984). The lipophilic 99mTc-d,l-HMPAO complex (log P = 1.2) can cross the BBB and is extracted with high efficiency (E = 0.8) from blood at normal flow levels (Holmes et al. 1985; Lassen and Andersen 1988; Lassen et al. 1987). Cerebral extraction corresponds to approximately 5% of the injected radioactivity (Leonard et al. 1986; Neirinckx et al. 1987). The mesoform is not accumulated in the brain due to the stereospecificity of uptake (Sharp et al. 1986). The lipophilic 99mTc-d,l-HMPAO complex is decomposed rapidly in vivo, both in the blood and in the brain. Due to this instability, the secondary 99mTc-d,l-HMPAO complex, a charged complex, is formed (Neirinckx et al. 1988). The secondary complex cannot pass the BBB and is trapped inside the brain and in blood cells, i.e., the ionized molecule is trapped. After intravenous injection of a bolus of 99mTc-d,l-HMPAO complex, 50% of the radioactivity are eliminated from the circulation within 2±3 min; thus, when the lipophilic complex has been eliminated from the blood, no further exchange is observed (Lassen and Andersen 1988). After approximately 5 min, when the lipophilic radiotracer has disappeared both in the blood and in brain, the distribution of radioactivity in the brain is a true image of the initial blood flow (Lassen et al. 1987). The radioactivity pattern remains constant for 24 h. Elimination from the brain is very slow, approximately 1% per hour (Ell et al. 1987). After 24 h, > 70% of the tracer is still in the brain. The kidneys excrete 41% of the injected radioactivity over the first 48 h. Between 8.5 and 13.0% pass through the liver, thereby showing the main bile ducts and the gall bladder. Lung uptake averages 9%, and about 2% of the injected radiotracer localize in the myocardium (Ell et al. 1987). The lipophilic 99mTc-d,l-HMPAO complex accumulates in blood cells (80% in red cells, less in white cells and platelets); the blood shows approximately 12% radioactivity 1 h postinjection (Ell et al. 1987). A relatively high concentration of activity was observed in lacrimal glands of volunteers (Meyer et al. 1990).
Radiation Dose The excretory organs such as the kidneys and urinary bladder, along with the gallbladder wall, the upper large intestinal wall, the lower large intestinal wall, the small intestine, and the liver are the most exposed organs (ICRP 62). The effective (whole body)
257
258
12.5
99m
Tc-Labeled Brain Perfusion Agents
dose is 0.0093 mSv/MBq (International Commission on Radiological Protection 1991). The effective dose in adults (70 kg) resulting from 500 MBq (13.5 mCi) of intravenously injected 99mTc-HMPAO complex is 4.65 mSv.
Storage and Stability Storage. The lyophilized kit should be stored at 15±25 8C. Stability. The stabilized
99m
Tc-HMPAO complex may be used 4±6 h after preparation.
References Administration of Radioactive Substances Advisory Committee (1993) Technetium-labeled exametazime (HMPAO) (1993) In: Notes for guidance on the administration of radioactive substances to persons for purposes of diagnosis, treatment or research, Appendix 1, Part A, pp 22±30; and Administration of Radioactive Substances Advisory Committee ± ARSAC. 13(a) ibidem: Investigations ± Children and young persons (1993) In: Notes for guidance on the administration of radioactive substances to persons for purposes of diagnosis, treatment or research, Appendix 1, Part D, pp 34±35 Amersham Healthcare (1995) Product information for the Ceretec kit for the preparation of technetium Tc-99m exametazime injection. Amersham Healthcare, UK Andersen AR, Friberg HH, Schmidt JF, Hasselbalch SG (1988) Quantitative measurements of cerebral blood flow using SPECT and 99mTc-d,l-HMPAO compared to xenon-133. J Cereb Blood Flow Metab 8(Suppl 1):S69±S81 Asenbaum S, Reinprecht A, Brçcke T, Wenger S, Podreka I, Deecke L (1985) A study of acetazolamide-induced changes in cerebral blood flow using 99mTc-HM-PAO SPECT in patients with cerebrovascular disease. Neuroradiology 27:509±516 Ballinger JR, Reid RH, Gulenchyn KY (1988) Radiochemical purity of [99mTc]HM-PAO. J Nucl Med 29:572±573 (letter) Dormehl, IC, Oliver DW, Langen, K-J, Hugo N, Croft SA (1997) Technetium-99m-HMPAO, technetium-99m-ECD and iodine-123-IMP cerebral blood flow measurements with pharmacological interventions in primates. J Nucl Med 38:1897±1901 Ell PJ, DC Costa, ID Cullum, PH Jarritt, D Lui (1987) Ceretec rCBF atlas: the clinical application of rCBF imaging by SPECT: Amersham International, UK Council of Europe (2005) Technetium 99mTc exametazime injection. In: European Pharmacopeia 5.0, monograph no 1925. Council of Europe, Maisonneuve, Sainte-Ruffine, p 1214 Heiss W-D (1983) Flow thresholds for functional and morphological damage of brain tissue. Stroke 14:329±331 Heiss W-D, Herholz K, Podreka I, Neubauer I, Pietrzyk U (1990) Comparison of 99mTc-HM-PAO SPECT with 18F-fluoromethane PET in cerebrovascular disease. J Cereb Blood Flow Metab 10:687±697 Holm S, Andersen AR, Vorstrup S, Lassen NA, Paulson OB, Holmes RA (1985) Dynamic SPECT of the brain using a lipophilic technetium-99m complex, PnAO. J Nucl Med 26:1129±1134 Holman BL, Johnson KA, Gerada B, Carvalho PA, Satlin A (1992) The scintigraphic appearance of Alzheimer's disease: A prospective study using technetium-99m-HM-PAO SPECT. J Nucl Med 33:181±185 Holmes RA, Chaplin SB, Royston KG, Hoffmann TJ, Volkert WA (1985) Cerebral uptake and retention of 99mTc-hexamethyl-propyleneamine oxime (99mTc-HM-PAO). J Nucl Med Commun 6:443±447 International Commission on Radiological Protection (1991) Technetium-labelled HM-PAO (Ceretec) In: Annals of the ICRP, Radiological protection in biomedical research, ICRP publication 62, vol. 22., no. 3. Pergamon, Oxford, pp 11±13 Lassen NA (1966) The luxury-perfusion syndrome and its possible relation to acute metabolic acidosis localized within the brain. Lancet 2:1113±1115
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Lassen NA, Andersen AR (1988) Technetium-99m compounds for measurement of cerebral blood flow [reply]. J Nucl Med 29:1664±1465 Lassen NA, Sperling B (1993) Hyperfixation of HM-PAO in subactute ischemic stroke leading to spuriously high estimates of cerebral blood flow by SPECT. Stroke 24:193±194 Lassen NA, Andersen AR, Friberg H, Neirinckx RD (1987) Technetium-99m-HM-PAO as a tracer of cerebral blood flow distribution: A kinetic analysis. J Cereb Blood Flow Metab 7 (Suppl 1):S535 Lassen NA, Andersen AR, Friberg L, Paulson OB (1988) The retention of 99mTc-d,l-HM-PAO in the human brain after intracarotid bolus injection: A kinetic analysis. J Cereb Blood Flow Metab 8(Suppl 1):S13±S22 Leonard JP, Nowotnik DP, Neirinckx RD (1986) Technetium-99m d,l-HM-PAO: a new radiopharmaceutical for imaging regional brain perfusion using SPECT ± a comparison with iodine-123 HIPDM. J Nucl Med 27:1819±1823 Meyer JY, Thomson D, Mena I, Marcus CS (1990) Lacrimal gland dosimtery for the brain imaging agent 99mTc-HMPAO. J Nucl Med 31:1237±1239 Moretti JL, Defer G, Cinotti L, Cesaro P, Degos JD, Vigneron N, Ducassou D, Holman BL (1990) ªLuxury perfusionº with 99mTc-HM-PAO and 123I-IMP SPECT imaging during the subacute phase of stroke. Eur. J Nucl Med 16:17±22 Murase K, Tanada S, Fujita H, Sakaki S, Hamamoto K (1992) Kinetic behavior of Tc-99m HM-PAO in the human brain and quantification of cerebral blood flow using dynamic SPECT. J Nucl Med 33:135±143 Neirinckx RD, Canning LR, Piper IM, Nowotnik DP, Pickett RD, Holmes RA, Volkert WA, Forster AM, Weisner PS, Mariott JA, Chaplin SB (1987) Technetium-99m d,l-HM-PAO: a new radiopharmaceutical for SPECT imaging of regional cerebral blood perfusion. J Nucl Med 28:191± 202 Neirinckx RD, Burke JF, Harrison RC, Forster AM, Andersen AR, Lassen NA (1988) The retention mechanism of technetium-99m-HMPAO: intracellular reaction with glutathione. J Cereb Blood Flow Metab 8(Suppl 1):S4±S12 Podreka I, Suess E, Goldenberg G, Brçcke T, Mçller C, Lang W, Neirinckx RD, Deecke L (1987) Initial experience with technetium-99m-HM-PAO brain SPECT. J Nucl Med 28:1657±1666 Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radiopharmaceutical formulation problems. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 268±270, 272±289 Sharp PF, Smith FW, Gemmel HG, Lyall D, Evans NTS, Gvozdanovic D, Davidson J, Tyrrell DA, Pickett RD, Neirinckx RD (1986) Technetium-99m HM-PAO stereoisomers as potential agents for imaging regional cerebral blood flow: Human volunteer studies. J Nucl Med 27:171±177 Troutner DE, Volkert WA, Hoffmann TJ, Holmes RA (1984) A neutral lipophilic complex of 99mTc with a multidentate amine oxime. Int J Appl Radiat Isot 35:467±470 United States Pharmacopeial Convention (2005) Official Monographs: USP 28, technetium Tc 99m exametazime injection. United States Pharmacopeia (USP) 28±national formulary (NF) 23, p 1855
259
260
12.5
99m
12.5.2
Tc-Labeled Brain Perfusion Agents 99m
Tc-ECD (Ethyl Cysteinate Dimer)
J. Imre and I. Zolle Chemical structure
Chemical name (N,N'-1,2-ethylenediyl-bis-L-cysteine) diethyl ester dihydrochloride (ECD) Ethyl-Cysteinate-Dimer (L,L-ECD) Bicisate (USP) Technetium Tc 99m bicisate injection (USP) Tc(V)oxo-N,N'-ethylene di-cysteinate diethyl ester 99m Tc(V)oxo-L,L-ECD complex
Tc(V)O-L,L-ECD
Kit components
Listed trade names
Vial A:
Neurolite
Bicisate dihydrochloride
0.9 mg
Stannous chloride, dihydrate
0.072 mg
Edetate disodium, dihydrate
0.36 mg
Mannitol
Bristol-Myers Squibb
24 mg
Vial B: Sodium phosphate dibasic Heptahydrate
4.1 mg
Sodium phosphate monobasic monohydrate
0.46 mg
Water for injection
ad 1 ml
Preparation The Neurolite kit consists of two nonradioactive vials, vial A and vial B. Vial A contains the lyophilized active ingredients in a nitrogen atmosphere. A volume of 3 ml of saline is added to vial A, and the vial inverted to dissolve the kit content. Within 30 s, 1 ml from vial A should be withdrawn and injected into vial B. Vial B contains 1 ml phosphate buffer, pH 7.6 Ô 0.4. It is placed into a lead shield. A volume of 2 ml of 99mTc-pertechnetate (925 MBq±3.7 GBq; 25±100 mCi) is added aseptically to vial B. Labeling is performed by adding aseptically 1 ml from vial A to vial B, and allowed to react for 30 min at room temperature (DuPont Merck Pharmaceutical 1995). 99m Tc-ethyl cysteinate dimer (ECD) is a clear, colorless, sterile, solution suitable for intravenous injection. The pH value is between 6.6 and 7.8.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Description of the Kit The kit formulation (vial A) contains bicisate dihydrochloride exclusively as the l,l-enantiomer (DuPont Merck Pharmaceutical 1995). After reconstitution with 3 ml saline, the pH of vial A is 2.7 Ô 0.25. One third of bicisate (0.3 mg) is used for labeling. The rest is discarded. Storage of residual portions of Neurolite in a freezer and subsequent labeling within 4 weeks has been suggested (Verbeke et al. 1997). Initially, reduced 99mTc activity and ethylenediaminetetraacetic acid (EDTA) form an intermediary complex, which is transformed slowly by ligand exchange to the 99m Tc(V)-ECD complex, showing high in vitro stability. Originally, glucoheptonate had been used instead of EDTA (Cheesman et al. 1988). The diaminodithiol (DADT)-derived ligand ECD forms a stable complex with pentavalent oxo-technetium (Cheesman et al. 1988). 99mTc-ECD is a neutral, lipophilic complex with the chemical formula [TcO-l,l-ECD]0.
Clinical Applications Technetium-99m bicisate injection is indicated for brain scintigraphy to delineate focal perfusion abnormalities: · Diagnosis of acute cerebral infarction (stroke) when computer tomography (CT) is negative · Detection of inflammatory conditions in the brain · Detection of an abnormal focus in patients with head trauma after accidents · Differentiation of focal abnormalities in cerebral blood flow typical in multi-infarct dementia and degenerative dementia 99m
Tc-bicisate uptake follows linearity, with blood flow values up to 20 ml/100 g/min; however, ECD underestimates higher flow rates (Tsuchida et al. 1992). A considerable disadvantage is 3±4% washout per hour, which is difficult to correct for. Another deficit of ECD is an overestimation of infarct size in patients with subactute stroke (Lassen and Sperling 1994). The role of single-photon emission computer tomography (SPECT) with 99mTc-bicisate in ischemic stroke has been evaluated (Brass et al. 1994; Moretti et al. 1990). The kinetic parameters of 99mTc-ECD in the human brain have been compared with regional cerebral blood flow measurements with 133Xe SPECT (Devous et al. 1993) and with positron emission tomography (PET) (Tsuchida et al. 1992). The response of 99m Tc-ECD, 99mTc-examethylpropylene amine oxime HMPAO and 123I-IMP (N-isopropyl-p-[123I]-iodoamphetamine) to changes in cerebral blood flow was studied in primates (Dormehl et al. 1997). Time of Examination. Images of the brain are obtained from 10 min up to 6 h after injection. Optimal images occur 30±60 min after injection.
261
262
12.5
99m
Tc-Labeled Brain Perfusion Agents
Recommended Activities for Indications Cerebral perfusion scintigraphy: 370±740 MBq (10±20 mCi), injected intravenously 500 MBq (13.5 mCi) maximum recommended activity (Administration of Radioactive Substances Advisory Committee 1993) The manufacturer's instructions should be followed. Pediatric Dose. The amount of radioactivity for infants and children administered for brain scintigraphy is based on body weight, using the scaling factors given in Appendix 1 (Table A1.2). The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
Additional Information Patients should drink sufficient water before and after the study, and frequent bladder emptying should be encouraged in order to reduce the radiation exposure to the bladder wall. Technetium 99mTc-bicisate is eliminated primarily by renal excretion. It should be used with caution in patients with renal or hepatic impairment. The effect of acetazolamide on cerebral blood flow is underestimated with 99mTcECD (Dormehl et al. 1997).
Quality Control Radiochemical Purity. 99mTc-bicisate is not described in the European Pharmacopeia (United States Pharmacopeial Convention 2005). Thin-layer chromatography (TLC) using Baker-flex silica gel strips and an organic solvent is recommended by the manufacturer. Free 99mTc-pertechnetate and reduced, hydrolized 99mTc activity remain at the start, 99mTc-bicisate is measured at an Rf of 0.9±1.0. The radiochemical purity of 99mTcbicisate should not be less than 90%. The radiochemical purity should be determined prior to administration of 99mTcECD complex. If the labeling yield is less than 90%, the preparation should be discarded. Methods Recommended by the Manufacturer Thin-layer chromatography Stationary phase: Solvent: Developing time: Rf values:
Baker-flex SG 1B-F (precut to 2.5 ´ 7.5 cm) Ethyl acetate (high-performance liquid chromatography [HPLC] grade) 15 min 99m
Tc reduced, hydrolized: Tc-pertechnetate: 99m Tc-ECD complex: 99m
0.0±0.1 0.0±0.1 0.9±1.0 (>90%)
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Procedure: · Pour enough ethyl acetate into the TLC tank (beaker) to have a depth of 3±4 mm of solvent. · Cover the tank (beaker) with parafilm and allow it to equilibrate for approximately 10 min. · Dry the plates at 100 8C for 1 h and store in a desiccator. Remove predried plate from the desiccator just prior to use. · With a pencil, draw a faint line across the TLC plate at heights of 2, 4.5, and 7 cm from the bottom of the TLC plate. · Apply 5 ll of 99mTc-ECD injection solution at the center of the 2-cm mark. The diameter of the spot should not be greater than 10 mm. · Allow the spot to dry for 5±10 min, no longer. · Develop the plate in the covered TLC tank in fresh ethyl acetate to the 7.0-cm line (about 15 min). Remove the plate and dry in a ventilated hood. · Cut the TLC plate at the 4.5-cm mark with scissors. · Count the activity on each plate using a dose calibrator or a gamma counter. The time required to complete the entire procedure is approximately 30 min. The portion 4.5±7.0 cm contains the 99mTc-ECD complex and the bottom portion contains all labeled impurities. Calculate the percent radiochemical purity as: 99m
Tc-bicisate
%
Activity of upper piece 100 Activity of both pieces
Results of analysis (12 samples) Results were obtained by thin-layer chromatography described by the manufacturer. Labeling and stability
15 min (%)
6 h (%)
99m
95.1 Ô 0.41
93.2 Ô 0.34
4.8 Ô 0.24
6.0 Ô 0.17
Tc-ECD complex Tc-Na-pertechnetate and 99m Tc-reduced, hydrolized 99m
Pharmacokinetic Data After intravenous injection of a bolus of activity, 99mTc-l,l-ECD is distributed in the normal brain proportional to regional blood flow (Friberg et al. 1994). The lipophilic complex crosses the blood±brain barrier (BBB); cerebral uptake at 5 min postinjection is approximately 6.5% of the injected radioactivity (Holman et al. 1989; Leveille et al. 1989; Vallabhajosula et al. 1989). Within 4 h after injection, activity in the brain decreased to 3.7 Ô 0.3% injection dose (ID). The highest concentration of radioactivity in blood was measured at 1 min after intravenous injection, representing 19% of the injected dose (Vallabhajosula et al. 1989). The elimination from blood is rapid (T1/2 = 0.8 min), falling to 10% of the injected radioactivity at 2 min. One hour after the intravenous injection, less than 5% of the
263
264
12.5
99m
Tc-Labeled Brain Perfusion Agents
radioactivity is present, mainly as the nonlipophilic complex. 99mTc-bicisate is rapidly metabolized in blood; the hydrophilic acid metabolites are excreted through the kidneys, resulting in high brain to soft tissue concentration ratios early after injection and increasing over several hours (Holman et al. 1989). Brain retention of 99mTc-l,l-ECD is caused by intracellular stereospecific hydrolysis of the ester, producing the monoethyl ester (Walovitch et al. 1988). The d,d-isomer showed back-diffusion (T1/2 30 min). Once the metabolite is formed in the brain, it cannot cross the BBB in either direction (Walovitch et al. 1989). Effect of hypoxia on esterase function might interfere with reflow hyperemia in subacute stroke (Dormehl et al. 1997). Elimination from brain is expressed by two exponential functions, corresponding to half-times of 1.3 h (40%) and 42.3 h (60%, 3.8% ID), respectively (Vallabhajosula et al. 1989). 99m Tc-l,l-ECD is rapidly metabolized in the liver to the monoacid, and also to the diacid, 99mTc-l,l-EC. At 5 min postinjection, only a third of the blood activity (2.4% ID) was identified as the neutral, parent complex. The remaining activity was a mixture of polar metabolites. The amount of 99mTc-bicisate is decreasing rapidly, 10 min after injection there remains little parent complex in the blood for extraction by the brain. Metabolites were identified in urine by HPLC as 19.5% monoacid and 37.8% diacid (99mTc-EC) and 26.3% monoacid and 48.9% diacid at 2 hr and at 6 hr after administration of 99mTc-l,l-ECD, respectively (Walovitch et al. 1991). Excretion of 99mTc-l,l-ECD from the body is primarily by the kidneys, approximately 50% during the first 2 h, a total of 74% in 24 h. In feces 11.2 Ô 6.2% were measured in 48 h. Total body retention of 99mTc activity was less then 30% at 4 hr (Vallabhajosula et al. 1989).
Radiation Dose The excretory organs such as the kidneys and urinary bladder, along with the gallbladder wall, the upper large intestinal wall, the lower large intestinal wall, the small intestine, and the liver are the most exposed organs (International Commission on Radiological Protection 1991). The effective (whole body) dose for HMPAO is 0.0093 mSv/ MBq (International Commission on Radiological Protection 1991). Based on this value, the effective dose in adults (70 kg) resulting from 500 MBq of intravenously injected 99m Tc-ECD complex is 4.65 mSv.
Storage and Stability Storage. The lyophilized kit should be stored at 15±25 8C. Vial A should be protected from light. 99mTc-ECD injection is kept at room temperature with adequate shielding. Stability. The
99m
Tc-ECD injection is stable for 8 h after preparation.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
References Brass LM, Walovitch RC, Joseph JL, Leveille J, Marchand L, Hellman RS, Tikovsky RS, Masdeu JC, Hall KM, Van Heertum RL (1994) The role of single photon emission computed tomography brain imaging with 99mTc-bicisate in the localization and definition of mechanism of ischemic stroke. J Cereb Blood Flow Metab 14(Suppl 1):S91±S98 Cheesman EH, Blanchette MA, Ganey MV, Maheu LJ, Miller SJ, Watson AD (1988) Technetium99m ECD: Ester-derivatized diaminedithiol Tc complexes for imaging brain perfusion. J Nucl Med (Abstr)29:788 Devous MD, Payne JK, Lowe JL, Leroy RF (1993) Comparison of technetium-99m-ECD to xenon133 SPECT in normal controls and in patients with mild to moderate regional cerebral blood flow abnormalities. J Nucl Med 34:754±761 Dormehl, IC, Oliver DW, Langen, K-J, Hugo N, Croft SA (1997) Technetium-99m-HMPAO, technetium-99m-ECD and iodine-123-IMP cerebral blood flow measurements with pharmacological interventions in primates. J Nucl Med 38:1897±1901 DuPont Merck Pharmaceutical (1995) Product monograph Neurolite, issued by DuPont Merck Pharmaceutical, Wilmington, Del. Friberg L, Andersen AR, Lassen NA, Holm S, Dam M, (1994) Retention of 99mTc-bicisate in the human brain after intracarotid injection. J Cereb Blood Flow Metab 14(Suppl 1):S19±S27 Holman BL, Hellman RS, Goldsmith SJ, Mean IG, Leveille J, Gherardi PG, Moretti JL, Bischof-Delaloye A, Hill TC, Rigo PM, Van Heertum RL, Ell PJ, Bçll U, DeRoo MC, Morgan RA (1989) Biodistribution, dosimetry and clinical evaluation of Tc-99m ethyl cysteinate dimer (ECD) in normal subjects and in patients with chronic cerebral infarction. J Nucl Med 30:1018±1024 International Commission on Radiological Protection (1991) Technetium-labeled HM-PAO (Ceretec) In: Annals of the ICRP, radiological protection in biomedical research. ICRP publication 62, vol. 22, no. 3. Pergamon, Oxford, pp 11±13 Lassen NA, Sperling B (1994) 99mTc-Bicisate reliably images CBF in chronic brain diseases but fails to show reflow hyperemia in subacute stroke: report of a multicenter trial of 105 cases comparing 133-Xe and 99mTc-bicisate (ECD, Neurolite) measured by SPECT on the same day. J Cereb Blood Flow Metab 14(Suppl 1):S44±S48 Leveille J, Demonceau G, DeRoo MC, Rigo PM, Talliefer R, Morgan RA, Kupranick D, Walovitch RC (1989) Characterisation of technetium-99m-l,l-ECD for brain perfusion imaging. Part 2: biodistribution and brain imaging in humans. J Nucl Med 30:1902±1910 Moretti JL, Defer G, Cinotti L, Cesaro P, Degos JD, Vigneron N, Ducassou D, Holman BL (1990) ªLuxury perfusionº with 99mTc-HM-PAO and 123I-IMP SPECT imaging during the subacute phase of stroke. Eur. J Nucl Med 16:17±22 Tsuchida T, Yonekura Y, Sadato N, Iwasaki Y, Tamaki N, Konishi J, Fujita T, Matoba N, Nishizawa S, Magata Y (1992) Brain perfusion SPECT with [Tc-99m]-l,l-ethyl cysteinate dimer (ECD) in comparison with regional cerebral blood flow measured by PET: underestimation in the high flow range. J Nucl Med 33(Abstr):966 United States Pharmacopeial Convention (2005) USP 28 official monographs, technetium-Tc99m bicisate injection, United States pharmacopeia. United States Pharmacopeial Convention, p 1853 Vallabhajosula S, Zimmermann RE, Picard M, Stritzke P, Mena I, Hellman RS, Tikovsky RS, Stabin MG, Morgan RA, Goldsmith SJ (1989) Technetium-99m ECD: a new brain imaging agent: in vivo kinetics and biodistribution studies in normal human subjects. J Nucl Med 30:599±604 Verbeke K, Boonen C, Verbruggen AM (1997) Usefulness of residual fractions of l,l-ethylcysteinate dimer (Neurolite) for the preparation of 99mTc-l,l-ethylcysteinate dimer. Nucl Med Commun 18:535±539 Walovitch RC, Makuch J, Knapik G, Watson AD, Williams SJ (1988) Brain retention of 99mTc-ECD is related to in vivo metabolism. J Nucl Med 29(Abstr):747 Walovitch RC, Hill TC, Garrity ST, Cheesman EH, Burgess BA, O'Leary DH, Watson AD, Ganey MV, Morgan RA, Williams SJ (1989) Characterisation of 99mTc-l,l-ECD for brain perfusion imaging. Part 1: pharmacology of 99mTc-l,l-ECD in non-human primates. J Nucl Med 30:1892±1901 Walovitch RC, Franceschi M, Picard M, Cheesman EH, Hall KM, Makuch J, Watson MW, Zimmerman RE, Watson AD, Ganey MV, Williams SJ, Holman BL (1991) Metabolism of 99mTc-l,l-ethyl cysteinate dimer in healthy volunteers. Neuropharmacology 30:283±292
265
266
12.6
99m
12.6
Tc-Labeled Leukocytes
99m
Tc-Labeled Leukocytes
I. Zolle and Gy. Jnoki Chemical name D,L-Hexamethylpropylene
Kit components, Ceretec amine oxime
Exametazime
0.5 mg
D,L-HM-PAO
Tin(II)-chloride dihydrate
7.6 lg
Exametazime (Ph. Eur., USP)
Sodium chloride
4.5 mg
99m
Tc-D,L-HMPAO complex
Preparation The Ceretec kit contains the lyophilized, sterile ingredients in a multidose vial, sealed under nitrogen atmosphere. Labeling with 99mTc eluate is carried out under aseptic conditions by adding 5 ml of sterile sodium 99mTc-pertechnetate to the vial (0.37± 1.11 GBq). The shielded vial should be inverted gently for 10 sec to ensure complete dissolution of the lyophilisate. The reaction is allowed to proceed at room temperature for 5 min. The resulting pH is between 9.0 and 9.8. 99m Tc-hexamethylpropylene amine oxime (HMPAO) injection solution (0.1 mg/ml) is suitable for labeling leukocytes (GE Healthcare 2005).
Description of the Kit 99m
Tc-d,l-HMPAO complex is formed rapidly with reduced technetium at room temperature. A high labeling yield depends on maintaining tin in the reduced state. Any oxidant in the 99mTc eluate should be avoided. Only eluates from generators eluted regularly within 24 h after the previous elution may be used for labeling (GE Healthcare 2005). Isotopic dilution is observed with higher concentrations of 99Tc in the first eluate of new generators or after weekends, reducing the labeling efficiency (Ponto et al. 1987). The mean separation efficiency expressed as a percentage of the number of leukocytes present in the patients' blood is 40%. Only one fifth of the 99mTc-HMPAO injection solution (0.1 mg) is used for labeling. A maximum labeling efficiency of 80% during a 20-min incubation period was reported using 50 lg of d,l-HMPAO ligand in 1 ml of saline and 5 lg of tin(II)-salt, corresponding to an activity of 370±740 MBq (10± 20 mCi) of 99mTc-d,l-HMPAO (Mortelmans et al. 1989). Procedure for labeling autologous leukocytes. For cell labeling, aseptic techniques have to be used throughout (Danpure et al. 1988; Segall et al. 1994). The original labeling procedure described by the manufacturer has been adapted to using smaller amounts of blood. 1. Draw 2 ml of acid-citrate-dextrose (ACD) solution and 3 ml of a sedimentation agent into each of four 20-ml plastic nonheparinized syringes.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
2. Withdraw 15 ml of patient's blood into each syringe (a total of 60 ml), and mix gently by inversion. 3. Allow tubes to stand for 30±40 min at room temperature for erythrocytes to sediment. 4. When red cells have sedimented to approximately half the original volume of the blood, carefully draw up the leukocyte-rich, platelet-rich plasma (LRPRP) into a sterile tube and centrifuge at 150´g for 10 min. 5. While centrifuging the tubes, reconstitute one vial of HMPAO with 1.5 ml of 99mTc eluate containing 700±750 MBq (19±20 mCi) of 99mTc-pertechnetate (400±500 MBq/ ml, resp. 11±13 mCi/ml)). Gently invert the shielded vial for 10 sec to dissolve the lyophilisate. The generator eluate should not be more than 2 h old and the generator must have been eluted within the past 24 h. 6. Remove the supernatant PRP platelet-rich plasma (PRP) from the pellet of ªmixedº leukocytes, leaving the pellet almost dry. Save 10±15 ml of PRP for step 8. Agitate the tube gently to loosen the cells, and then pool all the cells into one tube. 7. Add exactly 1 ml of 99mTc-HMPAO to the tube with pooled leukocytes (the radioactivity of 99mTc-HMPAO is 400±500 MBq (11±13 mCi)). Mix gently and incubate the cells for 10 min at room temperature. 8. While incubating the leukocytes, centrifuge the PRP (obtained in step 6) for 5 min at 2000 ´ g to produce cell-free plasma (CFP). 9. After incubation, carefully add 3±5 ml of cell-free plasma (obtained in step 8) to the labeled cell suspension and mix. 10. Centrifuge at 150 ´ g for 10 min. 11. Add 3±5 ml of CFP containing ACD to the pellet of leukocytes; gently swirl for mixing. 12. Measure the radioactivity in the cells and in the supernatant (from step 10) and calculate the labeling efficiency (defined as the radioactivity in the cells expressed as a percentage of the sum of activities measured in the cells and in the supernatant). 13. The labeled leukocytes are ready to be reinjected. This should be performed without delay. Clinical Applications. Lipophilic 99mTc-exametazime has been shown to label leukocytes without affecting cell viability (Mortelmans et al. 1989; Peters et al. 1986; Roddie et al. 1988). HMPAO-labeled leukocytes have been used to locate site(s) of focal infection (e.g., abdominal abscess, abdominal sepsis) (Kelbaek et al. 1985); it is also indicated in conditions of fever of unknown origin, and in conditions not associated with infection such as inflammatory bowel disease (Arndt et al. 1993; Lantto et al. 1991). Labeled leukocytes have offered superior information when compared with bone scanning for the detection of osteomyelitis in children (Lantto et al. 1992). In a retrospective study in 116 patients with infection suspected to involve orthopedic implants, osteomyelitis, and septic arthritis, HMPAO-labeled leukocytes have been an effective tool in the diagnosis of chronic osteomyelitis and joint infection involving implants (sensitivity: > 97%, specificity: > 89%) (Devillers et al. 1995). Time of Examination. Planar imaging is performed at 1, 2 or 24 h after injection of labeled leukocytes. Recommended Activities for Indications. Abdominal scintigraphy: 185±370 MBq (5± 10 mCi) by intravenous injection
267
268
12.6
99m
Tc-Labeled Leukocytes
Additional Information Use only 99mTc eluate for labeling which has been obtained less than 2 h before use. Do not use methylene blue for stabilization, if 99mTc-HMPAO injection is used for leukocyte labeling (GE Healthcare 2005). 99m Tc-labeled leukocytes should be used within 1 h after preparation. A prolonged and delayed lung transit time and/or an abnormally high liver uptake are indications that some damage of the labeled cells occurred (Bowring 1986).
Quality Control Radiochemical Purity. 99mTc-exametazime is included in the European Pharmacopeia (Council of Europe 2002). Thin-layer chromatography on silica gel fiberglass plates, using two solvent systems is described to determine the radiochemical purity of the injection solution. In analogy, 99mTc-HMPAO-labeled leukocytes are analyzed under similar conditions. However, since cells do not migrate, free 99mTc-Na-pertechnetate and the unbound 99mTc-HMPAO complex are the major impurities to be quantified. The labeled product is analyzed before application to the patient. The radiochemical purity of 99mTc-labeled leukocytes is generally 95%. Thin-layer chromatography Aliquots are taken after incubation (step 7 above) to determine the labeling yield and also of the resuspended labeled leukocytes (step 11 above). Leukocyte labeling efficiency must be at least 52 Ô 4.1%. Higher labeling efficiencies have been reported (Mortelmans et al. 1989). · System I: Gelman instant thin-layer chromatography (ITLC) silica gel fiberglass plates and 2-butanone (methyl ethyl ketone [MEK]) as solvent: Reduced, hydrolized 99m Tc-technetium (C), the secondary 99mTc-HMPAO complex (A) and the 99mTcHMPAO-labeled leukocytes (E) remain at the start (A + C + E); unbound 99mTcHMPAO complex (D) and free 99mTc-Na-pertechnetate (B) are measured at the solvent front (B + D). · System II: Gelman ITLC silica gel fiberglass plates and saline as solvent: Reduced, hydrolized 99mTc-technetium (C), the secondary 99mTc-HMPAO complexes (A), lipophilic 99mTc-HMPAO complex (D), and 99mTc-HMPAO-labeled leukocytes (E) remain at the start (A + C + D + E); unbound 99mTc-Na-pertechnetate (B) moves with the solvent front. The difference between activity measured at the start (A + C + D + E) in solvent II (saline) minus activity measured at the start (A + C + E) in solvent I (MEK) corresponds to the percentage of unbound lipophilic 99mTc-HMPAO complex (D). Radioactivity measured at the solvent front in system II indicates the amount of free 99mTc-pertechnetate (B). Thus, the major radiochemical impurities (B and D) are used as an approximation of the purity of 99mTc-HMPAO-labeled leukocytes (E).
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
D (%) = %(A + C + D + E) ± % (A + C + E) B + D (%) = Unbound 99m
A B C D E
99m
Tc-activity
Tc-labeled leukocytes (%) = 100±%(B+D)
= Secondary 99mTc-HMPAO complex = 99mTc-pertechnetate (free) = Reduced, hydrolized 99mTc activity = Lipophilic 99mTc-HMPAO complex = 99mTc-HMPAO-labeled leukocytes
Pharmacokinetic Data Following reinjection of 99mTc-labeled leukocytes, normal distribution shows an initial transitory uptake in the lungs, and later, in the spleen, liver, and bone marrow. 99mTclabeled leukocytes represent approximately 37% of the circulating pool 40 min after injection. The kidneys and the gall bladder may also be visualized. During the first hours (1±6 h) nonspecific bowel activity is seen, 24 h after injection activity in the colon predominates. 99mTc activity is slowly released from the cells, with an observed elution rate of 20% during the first 24 h (Mortelmans et al. 1989; Segall et al. 1994), excreted partly by the kidneys and partly by the liver into the gall bladder. Damage to cells or clumping as a result of the labeling procedure will produce an abnormal distribution of 99mTc-labeled leukocytes (see Chap. 8).
Radiation Dose Intravenously injected leukocytes are distributed in liver, spleen, bone marrow, and other tissues; 40% are assumed to circulate in the blood with a half-time of 7 h, after which they are taken up in the same organs and tissues and in the same proportions as for the early uptake. The total uptake in the liver is 20%, in the spleen 25%, in red bone marrow 30%, and 25% in other tissues. Whole-body elimination is assumed to be 50% in 70 days. The model is based on granulocytes, which form the majority of cells in a preparation of mixed leukocytes (International Commission on Radiological Protection 1987). The effective (whole body) dose value is 0.011 mSv/MBq (International Commission on Radiological Protection 1991). The effective dose in adults (70 kg) resulting from an intravenous injection of 185 MBq of 99mTc-labeled leukocytes is 2.04 mSv. Good abscess images were reported with 100 MBq of 99mTc-labeled granulocytes, resulting in an effective dose to the patient of 1.2 mSv (Skretting et al. 1988).
Storage and Stability Storage. Kits should be stored at room temperature, and not stored above 25 8C. Stability. 99mTc-labeled leukocytes should be reinjected without delay after preparation. They should not be refrigerated or frozen.
269
270
12.6
99m
Tc-Labeled Leukocytes
References Arndt JW, van der Sluys Veer A, Blok D, Griffoen G, Verspaget HW, Lamers CB, Pauwels EK (1993) Prospective comparative study of technetium-99m-WBCs and indium-111-granulocytes for the examination of patients with inflammatory bowel disease. J Nucl Med 34:1052±1057 Bowring CS (1986) Imaging and quantitative scanning. In: Lewis SM, Baily RJ (eds) Radionuclides in hematology. Churchill Livingstone, Edinburgh, pp 151±172 Council of Europe (2005) Technetium 99mTc exametazime injection. In: European pharmacopeia 5.0, monograph no 1925. Council of Europe, Maisonneuve, Sainte-Ruffine, p 1214 Danpure HJ, Osman S, Carroll MJ (1988) The development of a clinical protocol for the radiolabelling of mixed leukocytes with 99mTc-hexamethylpropyleneamine oxime. Nucl Med Commun 9:465±475 Devillers A, Moisan A, Jean S, Arvieux C, Bourguet P (1995) Technetium-99m hexamethylpropylene amine oxime leukocyte scintigraphy for the diagnosis of bone and joint infections: a retrospective study in 116 patients. Eur J Nucl Med 22:302±307 GE Healthcare (2005) Product information for the Ceretec kit for the preparation of technetium Tc-99m exametazime injection. GE Healthcare, UK International Commission on Radiological Protection (1987) Technetium-labelled white blood cells (leukocytes). In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol. 18, no. 1±4. Pergamon, Oxford, pp 231±232 International Commission on Radiological Protection (1991) Technetium-labelled white blood cells (leukocytes). In: Annals of the ICRP, radiological protection in biomedical research. ICRP publication 62, vol. 22, no. 3. Pergamon, Oxford, pp 25±28 Kelbaek H, Fogh J, Gjorup T, Bçlow K, Vestergaard B (1985) Scintigraphic demonstration of subcutaneous abscesses with 99mTc-labelled leukocytes. Eur J Nucl Med 10:302±303 Lantto EH, Lantto TJ, and Vorne M (1991) Fast diagnosis of abdominal infections and inflammations with technetium-99m-HMPAO labeled leukocytes. J. Nucl Med 32:2029±2034 Lantto T, Kaukonen J-P, Kokkola A, Laitinen R, Vorne M (1992) Tc-99m HMPAO labeled leukocytes superior to bone scan in the detection of osteomyelitis in children. Clin Nucl Med 17:7± 10 Mortelmans L, Malbrain S, Stuyck J, De Backker C, Heynen MJ, Boogaerts M, De Roo M, Verbruggen A (1989) In vitro and in vivo evaluation of granulocyte labelling with (99mTc)d,l-HMPAO. J Nucl Med 30:2022±2028 Peters AM, Danpure HJ, Osman S, Hawker RJ, Henderson BL, Hodgson HJ, Kelly JD, Neirinckx RD, Lavender JP (1986) Clinical experience with 99mTc-HMPAO for labeling leukocytes and imaging inflammation. Lancet 25:946±949 Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radiopharmaceutical formulation problems. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 268±289 Roddie ME, Peters AM, Danpure HJ, Osman S, Henderson BL, Lavender PJ, CarrolMJ, Neirinckx RD, Kelly JD (1988) Inflammation: imaging with Tc-99m HMPAO-labelled leukocytes. Radiology 166:767±772 Segall GM, Lang H V, Chaovapong W (1994) In vitro evaluation of white blood cell labelling with 99m Tc-radiopharmaceuticals. Nucl Med Commun 15:845±849 Skretting A, Benestad HB, Sundrehagen H (1988) Whole-body distribution of 99mTc labelled autologous human granulocytes and radiation dose to cells and organs. Eur J Nucl Med 14:1±7 United States Pharmacopeial Convention (2005) Official Monographs: USP 28, technetium Tc 99m exametazime injection. United States Pharmacopeia (USP) 28±national formulary (NF) 23, p 1855
Chapter 12 Monographs of
12.7
99m
Tc Pharmaceuticals
99m
12.7.1
Tc-Labeled Bone Imaging Agents
99m
Tc-Pyrophosphate (PYP)
S. Kladnik and I. Zolle Chemical structure
Chemical name Sodium pyrophosphate ´ 10 H2O (PYP) Tin(II) diphosphate Technetium 99mTc tin pyrophosphate injection (Ph. Eur.) Technetium Tc 99m (pyrophosphate injection (USP)
Diphosphoric acid
99m
Tc-(Sn)-pyrophosphate injection 99m Tc-PYP Kit components
Commercial products
TechneScan PYP
TechneScan PYP
Mallinckrodt/Tyco
Pyroscint
Bristol-Meyers Squibb
AngioCis (TCK-7)
CIS Bio
HematoCis (TCK-11)
CIS Bio
PYP Tin(II)-chloride-dihydrate
11.9 mg 3.4 mg
AngioCis PYP Tin(II)-chloride dihydrate
100 mg 1.6 mg
HematoCis PYP
0.67 mg
Tin(II)-chloride dihydrate
0.01 mg
Preparation Each vial contains the freeze-dried, sterile components under nitrogen atmosphere in a multidose vial. Depending on the intended use, the vial is reconstituted with sterile saline or with sterile sodium 99mTc-pertechnetate injection solution. All transfers and vial stopper entries must be done using aseptic techniques. Following reconstitution, the vial is agitated to dissolve the lyophilized material. Labeling with 99mTc-pertechnetate is performed by adding 1±5 ml of sterile sodium 99m Tc-pertechnetate solution to obtain a suitable radioactivity concentration for intravenous application (Cis International 1985 a). 99m Tc-(Sn)-pyrophosphate (99mTc-PYP) injection solution is clear and free of particulate matter, the pH value is 5.±7.0.
271
272
12.7
99m
Tc-Labeled Bone Imaging Agents
Pretreatment of red blood cells (RBC) with PYP for in vivo labeling with 99mTc-Na-pertechnetate. Stannous pyrophosphate cold kits (except HematoCis) are used for in vivo labeling of erythrocytes with 99mTc-pertechnetate. In this case, the vial is reconstituted with sterile, nonpyrogenic saline or water, containing no preservatives. A volume of 3 ml resp. 10 ml is recommended by the manufacturer. The vial is agitated to dissolve the lyophilized material. After two resp. 5 min at room temperature, the preparation is ready for injection. A volume corresponding to 3.0±4.0 mg of stannous pyrophosphate is injected intravenously; 30 min later, 99mTc-Na-pertechnetate (555±740 MBq) (15± 20 mCi) is injected, also intravenously, for in vivo labeling of pretreated erythrocytes. The amount of PYP should not exceed 0.5 mg/kg body weight (Mallinckrodt Medical 1993). Factors to be considered for in vivo labeling have been presented (Zimmer et al. 1979). In vitro labeling of RBC with 99mTc-Na-pertechnetate. HematoCis (TCK-11) consists of two vials. Vial A contains a lyophilized, sterile formulation of 0.67 mg sodium pyrophosphate decahydrate and 0.01 mg stannous chloride dihydrate under nitrogen atmosphere. Vial B contains 10 ml of sterile saline under nitrogen atmosphere. Three milliliters of saline from vial B should be injected into vial A (this reducing solution must be used within 1 h). It should be stirred with a vortex for complete dissolution of freeze-dried material (Cis International 1985b). One and a half milliliters of the reducing solution A should be withdrawn and added to 2 ml of blood. After 5 min's incubation at room temperature and gentle agitation, the preparation is centrifuged and the plasma is removed. From vial B, 1±2 ml of saline should be added, the vial centrifuged, and then the supernatant withdrawn. For labeling, 0.8±1.4 ml of 99mTc-Na-pertechnetate (74±740 MBq) (2±20 mCi) is to be added to the RBC and incubated at room temperature for 5 min. The vial contents should be mixed well and then centrifuged to remove the supernatant. Measurements of both vials are then taken, and the labeling yield calculated. Generally, the labeling yield is approximately 97%. Labeled RBC may be resuspended with 0.5±1 ml of saline from vial B or with patient's plasma. The preparation is ready for intravenous injection of 99mTc-RBC. After heat alteration at 49.5 8C for 15 min, in vitro labeled RBC may be used for spleen scintigraphy. For this procedure, 99mTc-RBC should not be resuspended in plasma. Advantages of in vitro labeling: · High specific activity of 99mTc-RBC · Controlled unbound 99mTc activity · Bolus injection · Heat alteration for spleen scintigraphy For different kit applications, the manufacturer's instructions should be followed.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Description of the Kit Kits containing tin-pyrophosphate as a sterile, nonpyrogenic formulation are either reconstituted with sterile saline or with sterile sodium 99mTc-pertechnetate solution. 99m Tc-PYP has been used for imaging myocardial infarction; the cold kits serve as stannous agent for in vivo labeling of RBC. No bacteriostatic preservative is present in kits. Stannous pyrophosphate and 99mTc-(Sn)-pyrophosphate are sterile, pyrogen-free, clear, colorless solutions suitable for intravenous injection. Two stable complexes of technetium pyrophosphate have been identified at carrier levels by polarography, namely Tc(III) and Tc(IV) (Russell and Cash 1979). At pH below 6.0, 99mTc-(Sn)-pyrophosphate is described as a stable complex with Tc(IV). The active ingredient is sodium pyrophosphate (Na4P2O7 ´ 10 H2O). For reduction of 99m Tc-pertechnetate to lower oxidation states, tin(II) chloride or tin(II) fluoride is used. An optimal ratio of reducing agent/pyrophosphate must be maintained to prevent 99m Tc-Sn-colloid formation (Srivastava et al. 1977). Technical problems with kit production have been reported (Kowalsky and Dalton 1981).
Clinical Applications 99m
Tc(tin)-pyrophosphate has been introduced for skeletal imaging (Subramanian et al. 1972) and was evaluated in patients with bone disease (Cohen et al. 1972; Fletcher et al. 1973; Rampon et al. 1974). The diagnostic value of bone scintigraphy has been evaluated retrospectively (Kuntz et al. 1975) and compared with compounds showing higher in vivo stability, namely diphosphonate derivatives (Henne et al. 1975; Rudd et al. 1977). The advantages of 99mTc-PYP for imaging damaged myocardial tissue have been demonstrated (Bonte et al. 1974; Buja et al. 1977; Cowley et al. 1977; Davis et al. 1976; Kelly et al. 1979; Willerson et al. 1975, 1977; Zaret et al. 1976). Application of the cold kit PYP as an agent for labeling RBC with technetium has gained general acceptance (Hegge et al. 1978; Pavel et al. 1977; Thrall et al. 1978). 99m
Tc-RBC for radionuclide angiography · Regional imaging of blood pools (deep vein visualization) · Electrocardiogram (ECG)-triggered cardiac radionuclide ventriculography (ejection fraction, wall motion) · Detection of gastro intestinal hemorrhage, blood loss · Determination of RBC mass or blood volume · Spleen scintigraphy (heat-treated labeled RBC)
Time of Examination Acute myocardial necrosis: 90±120 min after intravenous injection of 99mTc(tin)-pyrophosphate Patients are imaged 24 h up to 6 days following the acute episode. Blood pool scintigraphy: 10 min after intravenous injection of sodium 99mTc-pertechnetate Spleen scintigraphy: 60 min after intravenous injection of 99mTc-RBC (denatured)
273
274
12.7
99m
Tc-Labeled Bone Imaging Agents
Recommended Activities for Indications Myocardial infarct imaging: 555±740 MBq (15±20 mCi) 99mTc(tin)-pyrophosphate: 0.5 mg/kg body weight (BW) Blood pool imaging: 555±740 MBq (15±20 mCi) 99mTc-pertechnetate Spleen scintigraphy: 37±75 MBq (1±2 mCi) 99mTc-RBC Pediatric Dose. The amount of radioactivity for infants and children is based on BW, using the scaling factors given in Appendix 1, Table A1.2. The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
Additional Information Patients should drink sufficient water and frequent bladder emptying should be encouraged, to reduce the radiation exposure to the bladder wall. Pyrophosphate in aqueous solutions slightly hydrolyzes to monophosphates, causing the formation of free pertechnetate and hydrolized colloidal technetium. Alteration of body distribution of 99mTc-pyrophosphate has been observed under various conditions (Crawford and Gumerman 1978; Hladik et al. 1982, 1987). Early studies in experimental models suggested that hydroxyapatite deposition is not detectable until 12±24 h after infarction (Bonte et al. 1974). Patients with cardiotoxic lesions resulting from an excess treatment with Adriamycin (doxorubicin) showed a diffuse accumulation of 99mTc-PYP in the heart, which otherwise is known only as localized uptake in focal lesions of myocardial infarction. Similar images have been observed in patients after defibrillation and reanimation treatment (Chacko et al. 1977). Excess aluminum (in patients taking drugs for peptic ulcer, containing aluminum hydroxide) could interfere with the biodistribution of 99mTc-PYP; almost all the radioactivity was found in the liver and spleen, possibly due to formation of a colloidal 99m Tc-species (Hladik et al. 1987). A reduction in the labeling yield of RBC has been reported for heparin, tin-overload, aluminum, prazocin, methyldopa, hydralazine, digoxin, quinidine, b-adrenergic blockers, (e.g., propanolol), calcium channel blockers (e.g., verapamil), nitrates (e.g., nitroglycerin), doxorubicin, iodinated contrast agents, and Teflon tubing (catheter) (Hladik et al. 1987). It is recommended to perform in vivo labeling of RBC prior to the administration of iodinated contrast media (Tatum et al. 1983). Diminished cardiac activity and increased renal activity has been observed when a heparinized catheter was used for in vivo red cell labeling with pyrophosphate. This was interpreted as formation of a 99mTc-heparin complex that localizes avidly in the kidneys (Hegge et al. 1978). Injection of Sn-pyrophosphate and 99mTc-pertechnetate through a heparin lock should be avoided.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Legal Aspects. Quality requirements of 99mTc-PYP are stated in the official monographs of the United States Pharmacopeia (USP) and the European Pharmacopeia (Ph. Eur.): Technetium 99mTc-tin pyrophosphate injection (Ph. Eur.) (Council of Europe 2005) Technetium Tc-99m pyrophosphate injection (USP) (United States Pharmacopeial Convention 2005)
Quality Control Radiochemical Purity. The Ph. Eur. requires thin-layer chromatography (TLC) on instant (I)TLC-silica gel (SG) fiberglass sheets for the identification of free 99mTc-Na-pertechnetate, using methyl ethyl ketone (MEK) as solvent. Unbound 99mTc-pertechnetate is measured at an Rf of 1.0. 99mTc-PYP and reduced, hydrolized 99mTc activity is identified at the origin. Reduced, hydrolized 99mTc activity is determined separately using sodium acetate (13.6%) as solvent. Hydrolized 99mTc-oxide is measured at the origin, and 99mTc-PYP and 99mTc-pertechnetate move with the solvent front. The sum of the measured radioactivity due to impurities obtained in two-solvent systems should not exceed 10% of the total radioactivity, according to the limits stated in the Ph. Eur. Analysis of various Tc-99m-labeled bone scanning agents has been reported (Krogsgaard 1976). The radiochemical purity of 99mTc-(Sn)-pyrophosphate should not be less than 90%. Conditions for thin-layer chromatography are shown below (Table 1 and 2) as are typical results of 99mTc-PYP analyses at different times after preparation. Table 1. Thin-layer chromatography on silica gel plates using two solvent systems
Stationary phase Solvent: Developing time:
System 1
System II
ITLC-SG (fiberglass) MEK 10 min
ITLC-SG (fiberglass) Sodium acetate 13.6% 10 min
Table 2. Relative migration of labeled components and quantification of impurities System I
99m Tc-reduced, hydrolized and 99mTc-PYP at the start Free 99mTc-pertechnetate at the solvent front
System II
Reduced, hydrolized 99mTc activity at the start 99m Tc-pertechnetate and 99mTc-PYP at the solvent front 99m
Tc-PYP (%) = 100±%(A+B)
(A) (B)
275
276
12.7
99m
Tc-Labeled Bone Imaging Agents
Results of analysis (12 samples) Results were obtained using the analystical methods described in the Ph. Eur. Labeling and stability
15 min (%)
99m
96.8 0.8 2.3
Tc-PYP complex Tc-Na-pertechnetate Tc reduced, hydrolized
99m 99m
6 h (%) 93.7 1.4 4.9
Pharmacokinetic Data After intravenous injection in patients, 99mTc-(Sn)-pyrophosphate accumulates in regions of active osteogenesis, and also in injured myocardium, mainly in necrotic tissue (Buja et al. 1977). Uptake in infarcted myocardium in experimental model (dog) was reported as 4.4% injected dose (ID)/g, compared with 0.31% in normal myocardial tissue (Bevan et al. (1980). Due to in vivo instability, 99mTc-PYP is no longer used for bone scintigraphy. Uptake of 99mTc-PYP in acute myocardial infarction was detected with higher sensitivity than were the known 99mTc-diphosphonate complexes (Kelly et al. 1979). Using a rat model, the percentage of injected activity per gram of infarct was approximately 2.4 times higher than with 99mTc-MDP (Davis et al. 1976). Visualization of the infarct can be effected from 24 h±7 days after the onset of symptoms and with maximum sensitivity (96%) between 48 and 72 h (Kelly et al. 1979). Pyrophosphate is subject to enzymatic hydrolysis by pyrophosphatase, which has been demonstrated in bone, the kidneys, and other tissues (Kornberg 1962; Russell et al. 1970). Several 99mTc-phosphate species are formed, showing a different biological distribution and causing poor image quality of the bone scintigram (Eckelman and Volkert 1982). Two hours after the intravenous injection of 99mTc-PYP, 10±30% of the injected radioactivity is taken up by bone structures; approximately 10% remain in the vascular space, declining to within 2±3% 24 h postinjection. (Krishnamurthy et al. 1975; Subramanian et al. 1975). The average urinary excretion is 60% of the administered dose in 24 h. The slow clearance of 99mTc-PYP is due to high binding to plasma proteins, 42% at 2 h postinjection (Saha and Boyd 1978). Stannous pyrophosphate has an affinity for RBC. It has been reported that stannous ion binds to the b-chain of hemoglobin. When 99mTc-Na-pertechnetate is injected 20± 30 min after the intravenous injection of the reducing solution, high labeling of the preloaded erythrocytes is obtained. Normally, 99mTc-Na-pertechnetate will diffuse freely in and out of the RBC; however, in the presence of stannous ion, it is reduced intracellularly and reacts with hemoglobin. Intravenous injection of 10±20 lg/kg BW of stannous pyrophosphate results in efficient labeling of the blood pool. At 10 min postinjection, 77 Ô 15% of the injected radioactivity remains in the circulation, and at 100 min postinjection, 71 Ô 14%. The radioactivity is decreasing slowly, approximately 6% in 2 h (Mallinckrodt Medical 1993). The effect of tin is long lasting. Preloaded RBC show labeling with 99mTc-Na-pertechnetate for up to 8 days after the injection of stannous pyrophosphate (Ancri et al. 1977). With doses of 0.02 mg of Sn(II)/kg BW, no negative effects were observed (Mallinckrodt Medical 1993). In vivo RBC labeling should not be repeated within 3 months.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Radiation Dose 99m
Tc-PYP is used for myocardial scintigraphy after intravenous injection. 99mTc-labeled erythrocytes are used for blood pool imaging, heat-denatured RBC for imaging the spleen. The most exposed organs are bone, bone marrow, bladder, kidneys, heart, and spleen. The radiation absorbed dose values previously obtained using the medical internal radiation dose (MIRD) scheme (Weber et al. 1989) correlate well with the effective (whole body) dose equivalent given in the ICRP 53 (International Commission on Radiological Protection (1987 a). A voiding period of 2 h was assumed. The effective (whole body) dose equivalent for 99mTc(Sn)-pyrophosphate is 0.008 mSv/MBq (ICRP 53, International Commission on Radiological Protection 1987 a). The effective dose in adults (70 kg) resulting from 740 MBq (20 mCi) of intravenously injected 99mTc(Sn)-pyrophosphate for cardiac imaging is approximately 5.9 mSv. The effective (whole body) dose equivalent for 99mTc-labeled erythrocytes is 0.0085 mSv/MBq (International Commission on Radiological Protection 1987 b). The effective dose in adults (70 kg) resulting from 740 MBq (20 mCi) of intravenously injected 99mTc-pertechnetate for angioscintigraphy corresponds to approximately 6.3 mSv. The absorbed radiation dose to the heart resulting from 99mTc-labeled RBC is 17.0 mGy and to the kidneys, 7.4 mGy. Approximately 15% of the activity is excreted in the urine during the first day (Porter et al. 1983). Activity is assumed to be distributed in the blood, being removed with a half-time of 60 h by renal excretion. The effective dose value for the intravenous injection of denatured RBC is 0.019 mSv/MBq (International Commission on Radiological Protection 1991). The effective dose in adults (70 kg) resulting from 75 MBq (2 mCi) of 99mTc-RBC (denatured) for spleen scintigraphy is approximately 1.4 mSv. The dose to the spleen after intravenous injection of 75 MBq (2 mCi) of denatured 99mTc-RBC is 42 mGy.
Storage and Stability Storage. The lyophilized kit is to be stored in the refrigerator at 2±8 8C. Stability.
99m
Tc-pyrophosphate injection solution is stable for 4 h at room temperature.
References Ancri D, Lonchampt M, Basset J (1977) The effect of tin on the tissue distribution of Tc-99m sodium pertechnetate. Radiology 124:445±450 Bevan JA, Tofe AJ, Benedict JJ, Francis MD, Barnett BL (1980) Tc-99m HMDP (hydroxymethylene diphosphonate): a radiopharmaceutical for skeletal and acute myocardial infarct imaging. II. Comparison of Tc-99m hydroxymethylene diphosphonate (HMDP) with other technetium-labeled bone imaging agents in a canine model. J Nucl Med 21:967±970 Bonte FJ, Parkey RW, Graham KD, Moore J, Stokely EM (1974) A new method for radionuclide imaging of myocardial infarcts. Radiology 110:473±474 Buja LM, Tofe AJ, Kulkarni PV et al (1977) Sites and mechanisms of localization of technetium99m phosphorus radiopharmaceuticals in acute myocardial infarcts and other tissues. J Clin Invest 60:724±740
277
278
12.7
99m
Tc-Labeled Bone Imaging Agents
Chacko AK, Gordon DH, Bennett JM et al (1977) Myocardial imaging with Tc-99m pyrophosphate in patients on Adriamycin treatment for neoplasia. J Nucl Med 18:680±683 Cis International (1985 a) Product information for the TCK-7 kit (AngioCis) for the preparation of technetium Tc-99m (Sn) pyrophosphate (PYP). Cis International, France Cis International (1985 b) Product information for the TCK-11 kit (HematoCis) for the preparation of technetium Tc-99m red blood cells (RBC). Cis International, France Cohen Y, Perez R, Henry R, Panneciere C (1972) Use of technetium 99m-labelled sodium pyrophosphate in skeletal scintigraphy. C R Acad Sci Hebd Seances Acad Sci D 275:1719±1721 Council of Europe (2005) Technetium 99mTc tin pyrophosphate injection. In: European pharmacopeia, monograph 129. Council of Europe, Maisonneuve, Sainte-Ruffine, p 1230 Cowley MJ, Mantle JA, Rogers WJ et al (1977) Technetium stannous pyrophosphate myocardial scintigraphy: reliability and limitations in assessment of acute myocardial infarction. Circulation 56:192±198 Crawford JA, Gumerman LW (1978) Alteration of body distribution of 99mTc-pyrophosphate by radiographic contrast material. Clin Nucl Med 3:305±307 Davis MA, Holman BL, Carmel AN (1976) Evaluation of radiopharmaceuticals sequestered by acutely damaged myocardium. J Nucl Med 17:911±917 Eckelman WC, Volkert WA (1982) In vivo chemistry of 99mTc-chelates. Int J Appl Radiat Isot 33:945±951 Fletcher JW, Solaric Georges E, Henry RE, Donato RM (1973) Evaluation of 99mTc-pyrophosphate as a bone imaging agent. Radiology 467±469 Hegge FN, Hamilton GW, Larson SM et al (1978) Cardiac chamber imaging: a comparison of red blood cells labelled with Tc-99m in vitro and in vivo. J Nucl Med 19:129±134 Henne W, Pixberg H-U, Pfannenstiel P (1975) Technetiumpolyphosphat und Technetiumdiphosphonat ± Eine vergleichende Untersuchung [in German]. Nucl Med 14:83±90 Hladik WB, Nigg KK, Rhodes BA (1982) Drug-induced changes in the biologic distribution of radiopharmaceuticals. Sem Nucl Med 12:184±218 Hladik WB, Ponto JA, Lentle BC, Laven DL (1987) Iatrogenic alterations in the biodistribution of radiotracers as a result of drug therapy: reported instances. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 193±202 International Commission on Radiological Protection (1987 a) Technetium-labelled phosphates and phosphonates. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, pp 213± 215 International Commission on Radiological Protection (1987 b) Technetium-labelled erythrocytes. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, pp 209±210 International Commission on Radiological Protection (1991) Technetium-labelled denatured erythrocytes. In: Annals of the ICRP, radiological protection in biomedical research. ICRP publication 62, vol 22, no 3. Pergamon, Oxford, pp 25±28 Kelly RJ, Chilton HM, Hackshaw BT, Ball JD, Watson NE, Kahl FR, Cowan RJ (1979) Comparison of Tc-99m pyrophosphate and Tc-99m methylene diphosphonate in acute myocardial infarction: concise communication. J Nucl Med 20:402±406 Kornberg A (1962) On the metabolic significance of phosphorolytic and pyrophosphorolytic reactions. In: Kasha M and Pullman B (eds) Horizons in biochemistry. Academic, New York, pp 251±264 Kowalsky RJ, Dalton DR (1981) Technical problems associated with the production of technetium [99mTc] tin(II) pyrophophate kits. Am J Hosp Pharm 38:1722±1726 Krishnamurthy GT, Huebotter RJ, Walsh CF, Taylor JR, Kehr MD, Tubis M, Blahd WH (1975) Kinetics of 99mTc-labeled pyrophosphate and polyphosphate in man. J Nucl Med 16:109±115 Krogsgaard OW (1976) Radiochemical purity of various Tc-99m-labelled bone scanning agents. Eur J Nucl Med 1:15±17 Kuntz D, Rain JD, Lemaire V, Sainte-Croix A, Ryckewaert A (1975) Diagnostic value of bone scintigraphy with technetium pyrophosphate. Study of 250 patients. Rev Rhum Mal Osteoartic 42:19±24 Mallinckrodt Medical (1993) Product information for TechneScan PYP for the preparation of (Sn) pyrophosphate (PYP) injection solution. Mallinckrodt Medical, The Netherlands Pavel DG, Zimmer AM, Patterson VN (1977) In vivo labeling of red blood cells with 99mTc: a new approach to blood pool visualization. J Nucl Med 18:305±308 Porter WC, Dees SM, Freitas JE, Dworkin HJ (1983) Acid-citrate-dextrose compared with heparin in the preparation of in vivo/in vitro technetium-99m red blood cells. J Nucl Med 24:383±387
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Rampon S, Bussiere JL, Prin P, Sauvezie B, Leroy V, Missioux D et al (1974) 250 studies of bone radioisotope scanning by tin pyrophosphate labeled with technetium 99m. Analytical and clinical study. Rev Rhum Mal Osteoartic 4:745±751 Rudd TG, Allen DR, Hartnett DE (1977) Tc-99m methylene diphosphonate versus Tc-99m pyrophosphate: biologic and clinical comparison. J Nucl Med 18:872±876 Russell CD, and Cash AG (1979) Complexes of technetium with pyrophosphate, etidronate, and medronate. J Nucl Med 20:532±537 Russell RGG, Mçhlbauer RC, Bisaz S et al (1970) The influence of pyrophosphate, condensed phosphates, phosphonates and other phosphate compounds on the dissolution of hydroxyapatite in vitro and on bone resorption induced by parathyroid hormone in tissue culture and in thyroparathyroidectomized rats. Calcif Tissue Res 6:183±196 Saha GB, Boyd CM (1978) Plasma protein-binding of 99mTc-pyrophosphate. Int. J Nucl Med Biol 5:236±239 Srivastava SC, Meinken G, Smith TD, Richards P (1977) Problems associated with stannous 99mTcradiopharmaceuticals. Int J Appl Radiat Isot 28:83±95 Subramanian G, McAfee JG, Bell EG, Blair RJ, Mara RE, Relston PH (1972) 99mTc-labeled polyphosphates as skeletal imaging agent. Radiology 102:701±704 Subramanian G, McAfee JG, Blair RJ, Kallfelz FA, Thomas FD (1975) Technetium-99m methylene diphosphonate ± a superior agent for skeletal imaging: comparison with other technetium complexes. J Nucl Med 16:744±755 Tatum JL, Burke TS, Hirsch JI et al (1983) Pitfall to modified in vivo method of technetium-99m red blood cell labeling ± iodinated contrast media. Clin J Nucl Med 8:585±587 Thrall JH, Freitas JE, Swanson D, Rogers WL, Clare JM, Brown ML, Pitt B (1978) Clinical comparison of cardiac blood pool visualization with technetium 99m red blood cells labeled in vivo and with technetium 99m human serum albumin. J Nucl Med 19:796±803 United States Pharmacopeial Convention (2005) Official Monographs: USP 28, technetium Tc 99m pyrophosphate injection. United States Pharmacopeia (USP) 28±national formulary (NF) 23, p 1862 Weber DA, Makler PT Jr, Watson EE, Coffey JL, Thomas SR, London J (1989) Radiation absorbed dose from technetium-99m-labeled bone imaging agents: MIRD dose estimate report no 13. J Nucl Med 30:1117±1122 Willerson JT, Parkey RW, Bonte FJ, et al. (1975) Technetium-99m stannous pyrophosphate myocardial scintigrams in patients with chest pain of varying etiology. Circulation 51:1046±1052 Willerson JT, Parkey RW, Buja LM et al (1977) Are 99mTc-stannous pyrophosphate myocardial scintigrams clinically useful? Clin Nucl Med 2:137±145 Zaret BL, Di Cola VC, Donabedian RK, Puri S, Wolfson S, Freedman GS, Cohen LS (1976) Dual radionuclide study of myocardial infarction: relationships between myocardial uptake of potassium-43, technetium-99m stannous pyrophosphate, regional myocardial blood flow and creatine phosphokinase depletion. Circulation 53:422±428 Zimmer AM, Pavel DG, Karesh SM (1979) Technical parameters of in vivo red blood cell labelling with technetium-99m. Nuklearmedizin 18:241±245
279
280
12.7
99m
12.7.2
Tc-Labeled Bone Imaging Agents 99m
Tc-Diphosphonates
I. Zolle and S. Kladnik 99m
Tc-DPD (Dicarboxypropane diphosphonate)
Chemical name
Chemical structure
3,3-Diphosphono-1,2-propane-dicarboxy acid, tetrasodium salt (DPD) 1,2-dicarboxypropane diphosphonate Dicarboxypropane diphosphonic acid Kit components DPD Tin(II)-chloride dihydrate
Commercial products 13.0 mg
Teceos
CIS bio international
0.23 mg
N-(4-aminobenzoyl)-L-glutamic acid, monosodium salt 1.0 mg
99m
Tc-HDP (Hydroxymethylene diphosphonate)
Chemical name
Chemical structure
Hydroxymethylene diphosphonic acid, disodium salt (HMDP, HDP) Hydroxymethylene diphosphonate Oxidronate (USP) Technetium Tc 99m oxidronate injection (USP) Kit components
Hydroxymethylene diphosphonic acid Commercial products
Oxidronate
3.0 mg
Tin(II)-chloride dihydrate
0.24±0.45 mg OsteoCis (TCK-21) CIS bio international
Gentisic acid resp.
0.84 mg
Ascorbic acid
0.75 mg
Sodium chloride
10 mg
TechneScan HDP
Mallinckrodt Medical
Chapter 12 Monographs of 99m
99m
Tc Pharmaceuticals
Tc-HEDSPA (Hydroxyethylidene diphosphonate)
Chemical name
Chemical structure
1-Hydroxyethylidene-1,1-diphosphonic acid, disodium salt (HEDSPA) Ethylidene-1-hydroxy-1,1-disodium phosphonate (EHDP) Hydroxyethylidene diphosphonate Etidronate (USP) Technetium Tc-99m etidronate injection (USP) Kit components
Hydroxethylidene diphosphonic acid
Commercial products
Etidronate disodium salt
0.75 mg
HEDSPA
Union Carbide *
Stannous tartrate
0.18 mg
Osteoscan
Proctor and Gamble
Hydrochloric acid q.s.
pH = 4
No longer commercially available
* HEDSPA Unit dose kit: Etidronate disodium tin kit (80 lg stannous ion) 99m
Tc-MDP (Methylene diphosphonate)
Chemical name
Chemical structure
Methylene diphosphonic acid, disodium salt (MDP) Methylene diphosphonate Medronate (Ph. Eur.; USP) Technetium Tc 99m medronate injection (Ph. Eur.; USP)
Methylene diphosphonic acid
Kit components
Commercial products
MedroCis:
MedroCis (TCK-14)
CIS bio international
Lenoscint
Bristol-Myers Squibb GE Healthcare
Methylene diphosphonate
10.0 mg
Tin(II)-chloride dihydrate
1.0 mg
Amerscan MDP
Ascorbic acid
1.8 mg
Amerscan Stannous GE Healthcare Agent
Preparation Kits for the preparation of diphosphonate complexes contain the lyophilized ingredients in a multidose vial. Labeling with 99mTc-pertechnetate is performed by adding 2±10 ml of sterile 99mTc eluate by aseptic techniques. When calculating the amount of radioactivity to be added, the labeling efficiency, number of patients, time of injection and radioactive decay must be taken into account. Activities corresponding to 6.6±18.5 GBq
281
282
12.7
99m
Tc-Labeled Bone Imaging Agents
(180±500 mCi) are recommended by the manufacturer. The vial is agitated to dissolve the lyophilized material. After 5±20 min at room temperature, the preparation is ready for injection. 99m Tc-diphosphonate injection solutions are clear and free of particulate matter; the pH value is 3.5±7.5 (3,3-diphosphono-1,2-propane-dicarboxy acid [DPD] 6.5±7.5). A special formulation of medronate (Amerscan Stannous Agent) is used for in vivo loading of red blood cells with stannous ion, preparatory to labeling with sodium 99m Tc-pertechnetate. Amerscan Stannous Agent contains a freeze-dried, sterile formulation of 6.8 mg sodium medronate, corresponding to 5.4 mg medronic acid as disodium salt, and 4.0 mg stannous fluoride. Upon reconstitution with 6 ml saline, the recommended amount for adults (70 kg) by intravenous injection is 2 ml, corresponding to 1.8 mg medronic acid and 1.3 mg stannous fluoride.
Description of the Kit Each vial contains the freeze-dried, sterile components under nitrogen atmosphere in a multidose vial. 99mTc-Na-pertechnetate used for labeling must be free from any oxidizing agent, using a solution of 0.9% sodium chloride (saline) as diluent. No bacteriostatic agents are present in kits. In order to prevent oxidative reactions, kits are purged with nitrogen gas, the amount of tin reducing agent might be increased, and/or antioxidants might be added (Saha 1998). The active ingredients are diphosphonic acids ± dicarboxypropane diphosphonic acid (DPD), hydroxymethylene diphosphonic acid (HDP or HMDP), hydroxyethylidene diphosphonic acid (EHDP), methylene diphosphonic acid (MDP) ± or their sodium salts. As stabilizers are used N-(4-aminobenzoyl)-l-glutaminic acid, gentisic acid (2,5dihydroxybenzoic acid), ascorbic acid, or carbamide. For reduction of 99mTc-pertechnetate to lower oxidation states, tin(II) chloride and tin(II) fluoride are employed. Commercial kit formulations contain various quantities of active ingredients; some formulations use gentisic acid as a stabilizer of stannous ion (Tofe and Francis 1976; Tofe et al. 1980). Reduced, hydrolized 99mTc activity has been a common impurity. Colloid formation is also caused by aluminum in the 99mTc eluate (Ponto et al. 1987). An optimal ratio of reducing agent/diphosphonate must be maintained to prevent 99mTc-Sn-colloid formation (Srivastava et al. 1977). Optimal labeling conditions require carrier-free 99mTc eluate obtained from a generator that is eluted daily (Van Duzee and Bugaj 1981). Generally, diphopsphonate kits are used for several patient doses, keeping the injected mass of the 99mTc-diphosphonate complex below 1.0 mg (Castronovo and Callahan 1972). Thus, also in cases, when a single dose is prepared, the standard labeling conditions are applied. Pretreatment of red blood cells (RBC) with MDP for in vivo labeling with 99mTc-Na-pertechnetate. Stannous medronate freeze-dried formulation is reconstituted with sterile, nonpyrogenic saline. A volume of 6 ml is added (product information for Amerscan Stannous Agent). The vial is agitated to dissolve the lyophilized material. After 5 min at room temperature, the preparation is ready for injection (2 ml for one patient). The injection solution should be clear and free of particulate matter with a pH value between
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
5.5 and 7.5. Thirty minutes later, 99mTc-Na-pertechnetate (555±740 MBq) (15±20 mCi) is injected, also intravenously, for in vivo labeling of pretreated erythrocytes. Factors to be considered for in vivo labeling have been presented (Zimmer et al. 1979). For different kit applications, the manufacturer's instructions should be followed. Historical background. HEDSPA was the first Tc-99m-diphosphonate complex introduced to clinical practice by Castronovo and Callahan (1972). The use of EHDP was proposed by several groups (Pendergrass et al. 1973; Tofe and Francis 1972; Subramanian et al. 1972; Yano et al. 1973). Large numbers of patients were studied and compared with polyphosphate and pyrophosphate (Ackerhalt et al. 1974; Dunson et al. 1973; Genant et al. 1974; Hughes et al. 1975; Krishnamurthy et al. 1974); however, not all reports were favorable. MDP was introduced as a superior agent (Subramanian et al. 1975) and served as a reference for later developments (Russel and Cash 1979). HMDP, or HDP, showed favorable characteristics in early studies (Bevan et al. 1980; Domstad et al. 1980; Francis et al. 1980; Fogelman et al. 1981); after critical evaluation it was concluded that there was no significant difference between HMDP and MDP. DPD was developed at Hæchst, Germany (Schwarz and Kloss 1981; Schwarz et al. 1991), and compared favorably with MDP (Buell et al. 1982; Godart et al. 1986; Hale et al. 1981; Pauwels et al. 1983; Schroth et al. 1984). DPD is another efficient phosphonate complex that has been widely used as Teceos. The merits of available diphosphonate bone scanning agents have been discussed by Fogelman 1982.
Clinical Applications Skeletal scintigraphy with 99mTc-diphosphonate complexes. · Diagnosis of bone disease, e.g., primary bone tumors, metastatic bone tumors · Metabolic bone disease, osteomyelitis · Localization of fractures (stress and hairline fractures, fractures of the small bones of the hands and feet) · Evaluation of painful arthroplasties of the knee and hip · Evaluation of bone pain in patients with negative x-ray Radionuclide angiography with 99mTc-RBC · Regional imaging of blood pools (deep vein visualization) · Electrocardiogram (ECG)-triggered cardiac radionuclide ventriculography (ejection fraction, wall motion) An overview on the clinical application of radionuclide imaging in skeletal disease provides methodological detail (McAfee 1987). Amerscan Stannous Agent facilitates in vivo labeling of RBC; therefore, 99mTc-medronate is also used for blood pool scintigraphy (Gray et al. 1979). Time of Examination Bone imaging:
2 h after intravenous injection
283
284
12.7
99m
Tc-Labeled Bone Imaging Agents
Blood pool scintigraphy:
10 min after intravenous injection of sodium netate
99m
Tc-pertech-
Recommended Activities for Indications Bone scintigraphy: 370±740 MBq (10±20 mCi) Blood pool imaging: 555±740 MBq (15±20 mCi) (99mTc-pertechnetate) Pediatric Dose. The amount of radioactivity for infants and children administered for bone scintigraphy is based on body weight, using the scaling factors given in Appendix 1, Table A1.2. The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
Additional Information Patients should be encouraged to drink sufficient water and to empty the bladder before scintigraphy is started. Frequent bladder emptying is recommended to reduce the radiation exposure to the bladder wall. When kits containing large amounts of stannous ion were used for bone imaging, 99m Tc-labeling of RBC for up to 2 weeks after administration of 99mTc-PYP was observed (Ancri et al. 1977). Alteration of body distribution of 99mTc-phosphonates has been observed under various conditions (Hladik et al. 1982, 1987). Presence of aluminum in the generator eluate and treatment with aluminum-containing drugs may result in colloid formation, with liver and spleen uptake and trapping of particles in lung capillaries (Zimmer and Pavel 1978). Colloid formation is also observed at elevated pH above 8.5 (Chaudhuri 1976). The influence of iron and iron-containing drugs on the retention of diphosphonates has been observed frequently (Hladik 1987). A localized muscular accumulation of iron-dextran at the injection site was reported (Byun et al. 1976). After intravenous infusion of iron containing drugs or in cases of chronic iron overload in chronic diseases, a change in the bone-to-kidney ratio of diphosphonate complexes has been reported, namely, a decrease in bone uptake and an increase in accumulation in renal parenchyma (McRae et al. 1976). Dissociation of the 99mTc-diphosphonate complex and a conversion into the renaltropic gluconate was proved in the presence of ionic iron(II) and calcium. In vivo alteration of the complex was concluded from an increase in renal uptake even after infusion of dextrose. Long-term treatment with glucocorticosteroids results in a decrease in bone uptake. This phenomenon may not be explained as interference between a pharmaceutical and a radiopharmaceutical but by the drug-induced osteoporosis (Conklin et al. 1983). Another case report described the diffuse accumulation of 99mTc-MDP in the liver of a patient with methotrexate-induced hepatotoxicity. The authors postulated that inhibition of protein synthesis by methotrexate caused a disruption of the cell membranes, resulting in the inflow of calcium ions. The high affinity of MDP for calcium leads to diffuse uptake of tracer in the liver (Hladik et al. 1982). Since the stability of 99mTc-diphosphonate complexes may be affected, 99mTc-diphosphonates should not be mixed with other drugs or components nor injected simultaneously.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Legal Aspects. Quality requirements of 99mTc-diphosphonates are stated in the official monographs of the European Pharmacopeia (Ph. Eur.) and the United States Pharmacopeia (USP): 99m Tc-MDP Technetium Tc-99m medronate injection in USP 28 (United States Pharmacopeial Convention 2005) Technetium 99mTc medronate injection in Eur. Ph. 5.0 (Council of Europe 2005) 99m Tc-HDP Technetium Tc-99m oxidronate injection in USP 28 99m Tc-EHDP Technetium Tc-99m etidronate injection in USP 28
Quality Control Radiochemical Purity. 99mTc-medronate is included in the pharmacopoeias and may serve as an example for the analysis of other 99mTc-diphosphonates. The Ph. Eur. requires thin-layer chromatography (TLC) on instant (I)TLC-silica gel (SG) fiberglass sheets, using two separate solvent systems. · System I: Separation of 99mTc-pertechnetate in organic solvent methyl ethyl ketone (MEK): 99mTc-diphosphonates and hydrolized 99mTc activity remain at the start; free 99m Tc-pertechnetate is measured at the solvent front. · System II: Separation of reduced, hydrolized 99mTc activity using sodium acetate (13.6%): 99mTc-diphosphonates and free 99mTc-pertechnetate move with the solvent front; colloidal activity is measured at the start. Impurities. Free 99mTc-pertechnetate and colloidal activity are expressed as a percentage of the sum of the radioactivity measured in systems A and B, not exceeding 5%. 99mTcpertechnetate does not exceed 2%. The radiochemical purity of 99mTc-medronate is not less than 95% (Ph. Eur.). Thin-layer chromatography Analysis of various Tc-99m-labelled bone scanning agents has been reported (Krogsgaard 1976). Conditions for thin-layer chromatography are shown below (Table 1 and 2), as are results of 99mTc-MDP analyses at different times after preparation. Three different solvents were evaluated in each TLC system. Table 1. Thin-layer chromatography using silica gel and three solvents in each system System I
System II
Stationary phase:
ITLC-SG (fiberglass)
ITLC-SG (fiberglass)
Solvent: (a) (b) (c)
MEK Methanol±acetone, 1 : 1 Acetone
Sodium acetate 13.6% Saline Saline
Developing time:
10 min
10 min
285
286
12.7
99m
Tc-Labeled Bone Imaging Agents
Table 2. Relative migration of labeled components and quantification of impurities System I
99m Tc-reduced, hydrolized and 99mTc-MDP at the start Free 99mTc-pertechnetate at the solvent front
System II
Reduced, hydrolized 99mTc activity at the start 99m Tc-pertechnetate and 99mTc-MDP at the solvent front
(A) (B)
99m
Tc-MDP (%) = 100±%(A+B)
Results of analysis (12 samples) Shown are results of 99mTc-MDP analyses obtained with three different solvents, as described in Table 1. The consistent values of free 99mTc-pertechnetate and hydrolized 99m Tc activity measured at different times after preparation (a), favor the use of MEK and sodium acetate (13.6%), as stated in the Ph. Eur. However, saline may be used instead. Labeling and stability
15 min (%)
6 h (%)
Solvent no.
a
b
c
a
b
c
99m
98.0 1.4 0.6
96.7 2.8 0.4
96.4 3.2 0.4
97.4 1.9 0.6
95.2 4.3 0.5
95.0 4.5 0.5
Tc-MDP complex Tc-Na-pertechnetate 99m Tc-reduced, hydrolized 99m
Biological Test (Ph. Eur.). The biodistribution of 99mTc-MDP should be determined in three rats, according to the procedure in the Ph. Eur. to demonstrate that not less than 2.5% of the radioactivity is found in the femur and not more than 1.0% is found in the liver. Calculate the radioactivity per unit mass in the femurs (A1), muscle (A2) and blood (A3). The ratio of radioactivity per unit mass in the femur and muscle (A1/A2) is not less than 100, and in the femur and blood (A1/A3) is not less than 40.
Pharmacokinetic Data Following intravenous injection, 45±50% of 99mTc-diphosphonates (MDP, HDP, DPD) accumulate in the skeleton, while most of the rest is excreted in the urine. Maximum bone accumulation occurs 1 h after injection and remains constant for 72 h. The determining factors for bone uptake of 99mTc-phosphonate complexes are an increased blood flow to the skeleton and reactive bone formation, causing avid extraction by the bone mineral matrix (Jones et al. 1976; Sahni et al. 1993). Symmetric areas of increased activity concentration are seen in the metaphyseal zones in the growing skeleton. Ankles, knees, elbows, wrists, shoulder joints, pelvic bones, and vertebrae show increased uptake in the normal anterior bone scintigram (Saha 1987). The disappearance of 99mTc-phosphonate complexes from blood is affected by skeletal fixation and urinary excretion. Blood clearance proceeds with three half-times of elimination, a rapid phase (T1/2 = 3.5 min), an intermediate phase (T1/2 = 27 min), and a slow phase (T1/2 = 144 min). Transfer to the bone matrix corresponds to the intermediate phase. The total radioactivity in blood at 5 min, 2, 4, and 24 h after the intravenous injection was measured as 40, 10, 5.8, and 2.3%, respectively (Subramanian et al. 1975 a). Besides an increase in the osteogenic activity, bone uptake of 99mTc-diphosphonates is closely related to chemical structure, as demonstrated by the skeletal uptake of
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
EHDP, MDP, and HDP, differing by the substituents at the methylene bridge. Wholebody retention (24 h) in volunteers showed values of 18.4 (EHDP), 30.3 (MDP), and 36.6% (HDP), indicating a greater uptake of oxidronate (HDP) (Fogelman et al. 1981). These results agree with the conformational requirements derived from structure±activity relationship studies performed with mono- and disubstituted diphosphonates (Wang et al 1980). For normal renal function, elimination by glomerular filtration of the nonfixed complex is approximately 32% in 1 h, 47% in 2 h, and 60% in 6 h. The percentage of cumulative activity excreted in the urine during 24 h is 79.2% (EHDP) and 76.5% (MDP), indicating 75±80% 24-h urinary excretion of bone scanning agents (Subramanian et al. 1975 b). The relatively lower urinary excretion of HDP in dogs, namely, approximately 59%, is primarily resulting from high skeletal uptake, indicated by a femur-to-muscle ratio of 35 (Bevan et al. 1980). Protein binding of MDP has been reported as 22% at 2 h; in the case of EHDP, approximately 30% 3 h after injection (Saha and Boyd 1979; Subramanian et al. 1975a). 99m Tc-DPD shows lower binding to plasma protein and is excreted to a smaller extent in the urine (Schwarz et al. 1991). Whole-body retention at 24 h was 40.6% for DPD and 27.0% in the case of MDP (Buell et al. 1982). The bone-to-soft tissue ratio, which is important for skeletal scintigraphy, showed consistently higher values for 99m Tc-DPD, namely, an increase of 11.4% in normal volunteers and 7.3% in patients 2 h postinjection (Buell et al. 1982). The detection of bone metastases is based on increased regional uptake of 99mTc-diphosphonates; in a comparative study the diagnostic efficacy was determined for 99m Tc-MDP, 99mTc-HDP, and 99mTc-DPD, demonstrating equal detection rates for the three agents (Pauwels et al. 1983). Diphosphonates form stable Tc(IV) complexes. Contrary to inorganic phosphorus compounds, which are degraded in vivo, the organically bound diphosphonate complexes show high in vivo stability (Davis and Jones 1976). Stannous medronate has an affinity for RBC. It has been shown that stannous ion binds to the b-chain of hemoglobin. When 99mTc-Na-pertechnetate is injected 20± 30 min after the intravenous injection of the reducing solution, high labeling of the preloaded erythrocytes is obtained (Callahan et al. 1982). Approximately 15% of the injected activity is excreted in the urine during the first day (Porter et al. 1983).
Radiation Dose 99m
Tc-diphosphonate complexes are injected intravenously for bone scintigraphy. Tc-labeled erythrocytes are used for blood pool imaging. The most exposed organs are bone, bone marrow, bladder, kidneys, and the heart. The radiation absorbed dose values previously obtained using the medical internal radiation dose (MIRD) scheme (Weber et al. 1989) correlate well with the effective (whole body) dose equivalent given in the ICRP 53 (International Commission on Radiological Protection 1987 a). A voiding period of 3 h was assumed. The effective (whole body) dose value for 99mTc-diphosphonates is 0.0057 mSv/MBq (International Commission on Radiological Protection 1998). The effective dose in adults (70 kg) resulting from 740 MBq (20 mCi) of intravenously injected 99mTc-diphosphonate complexes for bone scintigraphy is approximately 4.2 mSv. 99m
287
288
12.7
99m
Tc-Labeled Bone Imaging Agents
The effective (whole body) dose value for 99mTc-labeled erythrocytes is 0.0066 mSv/ MBq (International Commission on Radiological Protection 1991). The effective dose in adults (70 kg) resulting from 740 MBq (20 mCi) of intravenously injected 99mTc-pertechnetate for angioscintigraphy corresponds to approximately 4.9 mSv. The absorbed radiation dose to the heart resulting from 99mTc-labeled RBC is 17.0 mGy, and to the kidneys, 7.4 mGy. Approximately 15% of the activity is excreted in the urine during the first day (Porter et al. 1983). Activity is assumed to be distributed in the blood, being removed with a half-time of 60 h, by renal excretion (International Commission on Radiological Protection 1987b).
Storage and Stability Storage. The lyophilized kits are to be stored in the refrigerator at 2±8 8C. Stability.
99m
Tc±diphosphonate injection solution is stable for 6 h at room temperature.
References Ackerhalt RE, Blau M, Bakshi S, Sondel JA (1974) A comparative study of three 99mTc-labeled phosphorus compounds and 18F-fluoride for skeletal imaging. J Nucl Med 15:1153±1157 Ancri D, Lonchampt M, Basset J (1977) The effect of tin on the tissue distribution of Tc-99m sodium pertechnetate. Radiology 124:445±450 Bevan JA, Tofe AJ, Benedict JJ, Francis MD, Barnett BL (1980) Tc-99m HMDP (hydroxymethylene diphosphonate): a radiopharmaceutical for skeletal and acute myocardial infarct imaging. I. Synthesis and distribution in animals. J Nucl Med 21:961±966 Buell U, Kleinhans E, Zorn-Bopp E, Reuschel W, Muenzing W, Moser EA, Seiderer M (1982) A comparison of bone imaging with Tc-99m DPD and Tc-99m MDP: concise communication. J Nucl Med 23:214±217 Byun HH, Rodman SG, Chung KE (1976) Soft tissue concentration of Tc-99m phosphates associated with injection of iron dextran complex. J Nucl Med 17:374±375 Callahan RJ, Froelich JW, McKusick KA, Leppo J, Strauss WH (1982) A modified method for the in vivo labeling of red blood cells with Tc-99m: concise communication. J Nucl Med 23:315± 318 Castronovo FP, Callahan RJ (1972) New bone scanning agent: 99mTc-labeled 1-hydroxyethylidenel,l-disodium phosphonate. J Nucl Med 13:823±827 Chaudhuri TK (1976) The effect of aluminium and pH on altered body distribution of Tc-99m EHDP. Int J Nucl Med Biol 3:37 Conklin JJ, Alderson PO, Zizic TM et al (1983) Comparison of bone scan and radiograph sensitivity in the detection of steroid-induced ischemic necrosis of bones. Radiology 147:221±226 Council of Europe (2005) Technetium 99mTc medronate injection. In: European Pharmacopeia 5.0, monograph no 641. Council of Europe, Maisonneuve, Sainte-Ruffine, p 1219 Davis MA, Jones AG (1976) Comparison of 99mTc-labeled phosphate and phosphonate agents for skeletal imaging. Semin Nucl Med 6:19±31 Domstad PA, Coupal JJ, Kim EE, Blake JS, DeLand FH (1980) 99mTc-hydroxymethane diphosphonate: a new bone imaging agent with a low tin content. Radiology 136:209±211 Dunson GL, Stevenson JS, Cole CM, Mellor MK, Hosain F (1973) Preparation and comparison of technetium-99m diphosphonate, polyphosphate and pyrophosphate in nuclear bone imaging radiopharmaceuticals. Drug Intell Clin Pharm 7:470±474 Fogelman I (1982) Diphosphonate bone scanning agents ± current concepts. Eur J Nucl Med 7:506±509
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Fogelman I, Pearson DW, Bessent RG, Tofe AJ, Francis MD (1981) A comparison of skeletal uptakes of three diphosphonates by whole-body retention: concise communication. J Nucl Med 22:880±883 Francis MD, Ferguson DL, Tofe AJ, Bevan JA, Michaels SE (1980) Comparative evaluation of three diphosphonates: in vitro adsorption (C14-labeled) and in vivo osteogenic uptake (Tc-99m complexed). J Nucl Med 21:1185±1189 Genant HK, Bautovich GJ, Singh M (1974) Bone seeking radionuclides: An in-vivo study of factors affecting skeletal uptake. Radiology 113:373±382 Godart G, Durez M, Bevilaqua M, Abramovici J, Robience Y (1986) Technetium-99m MDP vs technetium-99m dicarboxypropane diphosphonate. A clinical comparison in various pathologic conditions. Clin Nucl Med 11:92±97 Gray WR, Hickey D, Parkey RW, Bonte FJ, Roan P, Willerson JT (1979) In: Parkey RW, Bonte FJ, Buja LM, Willerson JT (eds) Qualitative blood pool imaging in clinical nuclear cardiology. Appleton-Century-Crofts, NY, pp 297±308 Hale TI, Jucker A, Vgenopoulos K, Sauter B, Wacheck W, Bors L (1981) Clinical experience with a new bone seeking 99mTc-radiopharmaceutical. Nucl Compact 12:54±55 Hladik WB, Nigg KK, Rhodes BA (1982) Drug-induced changes in the biologic distribution of radiopharmaceuticals. Semin Nucl Med 12:184±218 Hladik WB, Ponto JA, Lentle BC, Laven DL (1987) Iatrogenic alterations in the biodistribution of radiotracers as a result of drug therapy: reported instances. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 193±202 Hughes SPF, Jeyasingh K, Lavender PJ (1975) Phosphate compounds in bone scanning. J Bone Joint Surg (Br) 57:214±216 International Commission on Radiological Protection (1987a) Technetium-labelled phosphates and phosphonates. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, pp 213±215 International Commission on Radiological Protection (1987b) Technetium-labelled erythrocytes. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, pp 209±210 International Commission on Radiological Protection (1991) Technetium-labelled erythrocytes. In: Annals of the ICRP, radiological protection in biomedical research. ICRP publication 62, vol 22, no 3. Pergamon, Oxford, pp 25±28 International Commission on Radiological Protection (1998) Technetium-labelled phosphates and phosphonates (1998) In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, addendum to ICRP 53, publication 80, vol 28, no 3. Pergamon, Oxford, p 75 Jones AG, Francis MD, Davis MA (1976) Bone scanning: radionuclide reaction mechanism. Semin Nucl Med 6:3±18 Krishnamurthy GT, Tubis M, Endow JS, Singhi V, Walsh CF, Blahd WH (1974) Clinical comparison of the kinetics of 99mTc-labeled polyphosphate and diphosphonate. J Nucl Med 15:848±855 Krogsgaard OW (1976) Radiochemical purity of various Tc-99m-labeled bone scanning agents. Eur J Nucl Med 1:15±17 McAfee JG (1987) Radionuclide imaging in metabolic and systemic skeletal diseases. Semin Nucl Med 17:334±349 McRae J, Hambright P, Valk P, Bearden AJ (1976) Chemistry of Tc-99m tracers. II. In vitro conversion of tagged HEDP and pyrophosphate (bone seekers) into gluconate (renal agent). Effects of Ca and Fe(II) on in vivo distribution. J Nucl Med 17:208±211 Pauwels EKJ, Blom J, Camps JAJ, Hermans J, Rijke AM (1983) A comparison between the efficacy of 99mTc-MDP, 99mTc-DPD, 99mTc-HDP for the detection of bone metastases. Eur J Nucl Med 8:118±122 Pendergrass HP, Postsaid MS, Castronovo FP (1973) The clinical use of Tc-99m diphosphonate (HEDSPA). Radiol 107(3): 557±562 Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radio-pharmaceutical formulation problems. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 271±274 Porter WC, Dees SM, Freitas JE, Dworkin HJ (1983) Acid-citrate-dextrose compared with heparin in the preparation of in vivo/in vitro technetium-99m red blood cells. J Nucl Med 24:383±387 Russell CD, Cash AG (1979) Complexes of technetium with pyrophosphate, etidronate, and medronate. J Nucl Med 20:532±537 Saha GB (1987) Normal biodistribution of diagnostic radiopharmaceuticals. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 3±19
289
290
12.7
99m
Tc-Labeled Bone Imaging Agents
Saha GB (1998) Fundamentals of radiopharmacy, 4th edn. Springer, Berlin Heidelberg New York Saha GB, Boyd CM (1979) A study of protein-binding of 99mTc-methylene diphosphonate in plasma. Int J Nucl Med Biol 6:201±206 Sahni M, Guenther HL, Fleish H, Collin P, Martin J (1993) Biphosphonates act on rat bone resorption through the mediation of osteoblasts. J Clin Invest 91:2004±2011 Schroth H-J, Hausinger F, Garth H, Oberhausen E (1984) Comparison of the kinetics of methylene diphosphonate (MDP) and dicarboxypropane diphosphonic acid (DPD), two radio-diagnostics for bone scintigraphy. Eur J Nucl Med 9:529±532 Schwarz A, Kloss G (1981) Technetium-99m DPD ± a new skeletal imaging agent. J Nucl Med 22(Abstr):7 Schwarz A, Oberhausen E, Schroth HJ, Hale TJ (1991) Teceos. Scientific information on the labeling unit technetium-99m-3,3-diphosphono-1,2-propanedicarboxylic acid. Behring Diagnostika, Marburg, Germany Srivastava SC, Meinken G, Smith TD, Richards P (1977) Problems associated with stannous 99mTcradiopharmaceuticals. Int J Appl Radiat Isot 28:83±95 Subramanian G, McAfee JG, Blair RJ, Mehter A, Connor T (1972) 99mTc-EHDP: a potential radiopharmaceutical for skeletal imaging. J Nucl Med 13:947±950 Subramanian G, McAfee JG, Blair RJ, Kallfelz FA, Thomas FD (1975 a) Technetium-99m methylene diphosphonate ± a superior agent for skeletal imaging: comparison with other technetium complexes. J Nucl Med 16:744±755 Subramanian G, McAfee JG, Blair RJ (1975 b) An evaluation of 99mTc-labeled phosphate compounds as bone imaging agents. In: Subramanian G, Rhodes BA, Cooper JF, Sodd VJ (eds) Radiopharmaceuticals. Society of Nuclear Medicine, New York, pp 319±328 Tofe AJ, Francis MD (1972) In vitro optimization and organ distribution studies in animals with the bone scanning agent 99mTc-Sn-EHDP. J Nucl Med 13(Abstr):472 Tofe AJ, Francis MD (1976) In vitro stabilization of a low tin bone imaging kit. J Nucl Med 16:414±422 Tofe AJ, Bevan JA, Fawzi MB, Francis MD, Silberstein EB, Alexander GA, Gunderson DE, Blair K (1980) Gentisic acid: a new stabilizer for low tin skeletal imaging agents: concise communication. J Nucl Med 21:366±370 United States Pharmacopeial Convention (2005) United States pharmacopeia USP 28 official monographs: technetium Tc-99m medronate injection, technetium Tc-99m oxidronate injection, technetium Tc-99m etidronate injection. United States Pharmacopeial Convention, Rockville, Md. Van Duzee BF, Bugaj JE (1981) The effect of total technetium concentration on the performance of a skeletal imaging agent. Clin Nucl Med 6(Suppl):148 Wang TST, Fawwaz RA, Johnson LJ, Mojdehi GE, Johnson PM (1980) Bone-seeking properties of Tc-99m carbonyl diphosphonic acid, dihydroxy-methylene diphosphonic acid, and monohydroxy-methylene diphosphonic acid: concise communication. J Nucl Med 21:767±770 Weber DA, Makler PT Jr, Watson EE, Coffey JL, Thomas SR, London J (1989) Radiation absorbed dose from technetium-99m-labeled bone imaging agents: MIRD dose estimate report no 13. J Nucl Med 30:1117±1122 Yano Y, McRae J, Van Dyke DC, Anger HO (1973) Technetium-99m-labeled stannous ethane-1-hydroxy-1-diphosphonate: a new bone scanning agent. J Nucl Med 14:73±78 Zimmer AM, Pavel DG (1978) Experimental investigations of the possible cause of liver appearance during bone scanning. Radiology 126:813±816 Zimmer AM, Pavel DG, Karesh SM (1979) Technical parameters of in vivo red blood cell labeling with Technetium-99m. Nuklearmedizin 18:241±245
Chapter 12 Monographs of
12.8
99m
Tc Pharmaceuticals
99m
12.8.1
Tc-Labeled Renal Imaging Agents
99m
Tc-DMSA (Dimercaptosuccinic Acid)
J. Kærnyei and I. Zolle Chemical structure
Chemical name Dimercaptosuccinic acid (DMSA) Succimer (Ph. Eur.; USP) Technetium Tc 99m succimer injection (Ph. Eur.; USP) 99m
Tc(III)-dimercaptosuccinate (DMS)
99m
Tc(V)-DMSA
Dimercaptosuccinic acid
Kit components
Listed trade names
Amerscan DMSA:
Amerscan DMSA
GE Healthcare
Dimercaptosuccinic acid
1 mg
RenoCis (TCK-12)
CIS Bio
Tin(II)-chloride dihydrate
0.42 mg
TechneScan DMSA
Mallinckrodt/Tyco
Nephroscint
Bristol-Myers Squibb
DMSA
Rotop
Inositol
50.0 mg
Ascorbic acid
0.7 mg
Sodium chloride
2.9 mg
Preparation The kit contains the lyophilized ingredients in a multidose vial. Labeling is performed by adding 1±6 ml of 99mTc eluate under aseptic conditions. Sterile 99mTc-sodium pertechnetate (370±925 MBq, maximum 3.7 GBq) (10±25 mCi) is injected into the vial, and then mixed well to dissolve the lyophilisate. The reaction is allowed to proceed at room temperature for 15 min. 99m Tc-dimercaptosuccinic acid (DMSA) complex is a sterile, pyrogen-free, clear colorless solution suitable for intravenous injection. The pH should be between 2.3 and 3.5 (Ph. Eur.).
Description of the Kit The kit contains an isomeric mixture of DMSA as the mesoisomer (> 90%) and the d,l-isomers (< 10%). Upon addition of sterile sodium 99mTc-pertechnetate injection to the sterile, nonpyrogenic formulation, the renal 99mTc(III)-DMSA complex is formed. The lyophilized formulation is under nitrogen atmosphere to avoid oxidative processes; the introduction of air into the vial must be avoided. A breather needle should not be used. It is recommended to use a separate kit preparation for each patient. If
291
292
12.8
99m
Tc-Labeled Renal Imaging Agents
multiple doses are obtained from the same vial, care should be taken to avoid introducing air into the reaction vial, and the doses should be drawn as close together as possible and administered immediately (Taylor et al. 1980). The antioxidant inositol is used for stabilization of the 99mTc(III)-DMSA complex. 99m Tc eluate used for labeling should be obtained from a generator that is eluted daily (Van Duzee and Bugaj 1981). Initially, two complexes are formed under acidic conditions (pH 2.5), which yield the 99mTc(III)-DMSA complex at the end of the reaction time (15 min). An excess amount of stannous ion as well as a high molar ratio of Sn(II) to Sn(IV) have been postulated to yield Tc(III)-dimercaptosuccinate (DMS) (Ikeda et al. 1976). At least four 99mTc-DMSA complexes have been identified. It has been shown that pH, stannous ion concentration, and the concentration and purity of 99mTc-pertechnetate added for on-site preparation affect the formation of the different complexes (Ikeda et al. 1977 a, b). The formation of pentavalent 99mTc-DMSA complex occurs at elevated pH; therefore, 0.2 ml of a sterile solution of 3.5% sodium bicarbonate is added to the lyophilized DMSA kit before adding 99mTc-sodium pertechnetate (Ramamoorthy et al. 1987). The optimal pH for 99mTc(V)-DMSA formation is pH 7.5±8.0; the resulting concentration of stannous ion produced a complex with high stability (6 h). It was observed that addition of 99mTc-pertechnetate should follow immediately after mixing the powder with the alkaline sodium bicarbonate solution (Johannsen et al. 1979; Ramamoorthy et al. 1987; Westera et al. 1985). The negatively charged Tc(V)-oxo complex with DMSA consists of a TcO core having four sulfur atoms of the bidentate DMSA ligands arranged in a plane. The chemical formula is [TcO (DMSA)2]±1 (Saha 1997).
Clinical Applications Renal scintigraphy:
Static imaging (planar or tomographic) of the functional renal cortex Morphological studies of the renal cortex indicating space-occupying lesions and areas of reduced function kidney localization, delineating size and shape of the kidneys as well as defects
Scintigraphy of medullary carcinoma of the thyroid (MCT): Detection of metastatic lesions
For static imaging of the kidneys, the radiotracer is retained in the renal parenchyma by tubular fixation. The scintigram shows solely functional parenchyma. Necrotic tissue and inflammatory processes are not imaged; a tumor, cyst or abscess appears as cold area. Pentavalent 99mTc(V)-DMSA has been used in the diagnosis of MCT (Clarke et al. 1988; Ohta et al. 1984). Time of Examination Renal scintigraphy: 1±3 h after intravenous injection 6 h postinjection in the case of severely impaired kidney function Scintigraphy of MCT: 2±4 h after intravenous injection
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Recommended Activities for Indications Renal scintigraphy: 37±120 MBq (1±3.2 mCi) of 99mTc(III)-DMSA complex (0.3±1 mg DMSA) Scintigraphy of MCT: 370 MBq (10 mCi) of 99mTc(V)-DMSA complex The manufacturer's instructions should be followed. Pediatric Dose. The amount of radioactivity for infants and children is based on body weight (static imaging). Recommendations by the Pediatric Task Group of the European Association of Nuclear Medicine (EANM), based on body weight should be followed (see Appendix 1, Table A1.2).
Additional Information Because of the slow transfer of activity from blood to kidney, imaging should be delayed for 3 h after injection. Reduced cortical accumulation is observed in the presence of ammonium chloride, sodium bicarbonate, and mannitol based on experimental data (Yee et al. 1981). Medication with angiotensin-converting enzyme (ACE)-inhibitors (captopril) may cause reduced uptake in the affected kidney (Hovinga et al. 1989; Kopecky et al. 1990). A marked increase in hepatic activity may result from poor labeling conditions (Ikeda et al. 1976; Taylor et al. 1980). The patient should be adequately hydrated before 99mTc-DMSA scintigraphy.
Quality Control Radiochemical Purity. 99mTc-DMSA complex is described in the Ph. Eur. (Council of Europe 2005). Thin-layer chromatography (TLC) on silica gel (SG) fiberglass sheets in two different solvents is recommended for the detection of free 99mTc-pertechnetate and reduced, hydrolized 99mTc activity. Free 99mTc-pertechnetate is measured in methyl ethyl ketone (MEK) at the solvent front, reduced, hydrolized 99mTc activity is identified in saline at the start. The radiochemical purity of 99mTc-DMSA should not be less than 95%. The amount of free 99mTc-pertechnetate should not exceed 2% of the measured radioactivity (Ph. Eur.). Thin-layer chromatography (Ph. Eur.) Stationary phase: Solvent: Developing time:
Gelman ITLC-SG (fiberglass), 2 ´ 9.5 cm Methyl ethyl ketone (MEK) 10 min
Rf values:
99m
Tc-DMSA complex: Tc reduced, hydrolized: Tc-pertechnetate:
99m
99m
0.0±0.1 (> 95%) 0.0±0.1 0.9±1.0 (< 2%)
Reduced, hydrolized 99mTc activity is identified in saline at the origin. 99mTc-pertechnetate should not exceed 2% of the measured radioactivity. The sum of measured impurities (F+H) in both solvents must not exceed 5% of the total radioactivity.
293
294
12.8
99m
Tc-Labeled Renal Imaging Agents
Quantification of labeled components. Each chromatogram is measured (TLC linear analyzer or gamma counter), and the regional radioactivities are expressed as a percentage of the total recovered counts: 99m
Tc-DMSA
% 100
where F (%) = free
99m
F H
Tc-pertechnetate, and H (%) = hydrolized
99m
Tc activity.
Results of analysis (12 samples) Results were obtained by thin-layer chromatography in two solvent systems, at different times after labeling. Labeling and stability
15 min (%)
6 h (%)
99m
98.3 Ô 0.13 0.8Ô0.22 1.0Ô0.04
97.8 Ô 0.28 0.9Ô0.21 1.0Ô0.12
Tc-DMSA complex Tc-Na-pertechnetate 99m Tc-reduced, hydrolized 99m
Bioassay of 99mTc-DMSA Complex. To assure high renal uptake, the Ph. Eur. recommends a physiological test in rats. The required organ uptake values at 1 h after intravenous injection (at least two of three rats) are more than 40% of the applied radioactivity is measured in the kidneys, less than 10% in the liver, < 2% in the stomach, and < 5% in the lung.
Pharmacokinetic Data After intravenous injection, the 99mTc(III)-DMSA complex is taken up in the renal parenchyma (24% at 1 h), showing high cortical affinity (Lin et al. 1974). Uptake is related to renal cortical perfusion; the plasma clearance half-time in patients with normal kidney function is 56 min (Enlander et al. 1974). In patients, both kidneys are visualized 1 h after intravenous injection, with significant radioactivity in the bladder and negligible amounts in the liver, stomach, thyroid gland, or other organs. Most of the circulating 99mTc-DMSA is loosely bound to plasma proteins (Arnold et al. 1975). At 1 h after injection, approximately 25% of the injected radioactivity is measured in the proximal tubules, 30% in plasma, and 10% in the urine (Arnold et al. 1975; Bingham and Maisey 1978; Handmaker et al. 1975; Lin et al. 1974). Renal extraction is 4±5% per renal passage; the maximum accumulation in the renal cortex (48.3 Ô 3.0%) is reached 3 h after injection, 20% remain in the plasma, less than 10% in liver and muscle, and a urinary excretion of 11.4%. 99mTc-DMSA is exclusively excreted in the urine as the unchanged molecule; in the presence of renal tubular acidosis, urinary excretion is increased (de Lange et al. 1989). Urinary excretion in 24 h amounts to approximately 30% (Arnold et al. 1975). Renal accumulation is unaffected by probenecid and para-aminohippuric acid (PAH) (Lee and Blaufox 1985). Uptake is decreased by ACE inhibitors in the presence of renal artery stenosis (Hovinga et al. 1989; Kopecky et al. 1990). In renal failure, 99mTc-DMSA activity accumulates in the liver, the gallbladder, and the gut.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Pentavalent 99mTc(V)-DMSA differs structurally and has been evaluated for imaging medullary carcinoma of the thyroid (Ohta et al. 1984; Ramamoorthy et al. 1987). The sensitivity of lesion detection is 95%; no false positive uptake of 99mTc(V)-DMSA was seen in nine patients with a histologic diagnosis of medullary carcinoma. Accumulation of 99mTc(V)-DMSA was seen in both bone and soft tissue metastases. In comparison, 99m Tc-MDP detected all known metastases in bone, but none in soft tissue (Clarke et al. 1988).
Radiation Dose The most exposed organs are the kidneys, bladder wall, adrenals, liver, and spleen. The effective (whole body) dose equivalent is 0.016 mSv/MBq. The effective dose in adults (70 kg) resulting from an intravenous injection of 70 MBq (1.9 mCi) of 99mTc(III)-DMSA complex for renal scintigraphy is 1.12 mSv. The dose to the kidneys (renal cortex) after intravenous injection of 70 MBq (1.9 mCi) of 99mTc(III)-DMSA complex is 11.9 mGy. The effective dose in adults (70 kg) resulting from an intravenous injection of 370 MBq (10 mCi) of 99mTc(V)-DMSA complex for scintigraphy of medullary carcinoma is 3.0 mSv (Clarke et al. 1988).
Storage and Stability Storage. The lyophilized kit is stored at 2±8 8C in the refrigerator, protected from light. Stability. The ture.
99m
Tc(III)-DMSA injection solution is stable for 4 h at room tempera-
References Arnold RW, Subramanian G., McAfee JG, Blair RJ, Thomas FD (1975) Comparison of 99mTc complexes for renal imaging. J Nucl Med 16:357±367 Bingham JB, and Maisey MN (1978) An evaluation of the use of 99mTc-dimercaptosuccinic acid (DMSA) as a static renal imaging agent. Br J Radiol 51:599±607 Clarke SEM, Lazarus CR, Wraight P, Sampson C, Maisey MN (1988) Pentavalent 99mTc-DMSA, 131IMIBG, and 99mTc-MDP. An evaluation of three imaging techniques in patients with medullary carcinoma of the thyroid. J Nucl Med 29:33±38 Council of Europe (2005) Technetium [99mTc] succimer injection. European pharmacopeia monograph no. 643. Council of Europe, Maisonneuve, Sainte-Ruffine, p 1229 Enlander D, Weber PM, dos Remedios LV (1974) Renal cortical imaging in 35 patients: superior quality with 99mTc-DMSA. J Nucl Med 15:743±749 Handmaker H, Young BW, Lowenstein JM (1975) Clinical experience with 99mTc-DMSA (dimercaptosuccinic acid), a new renal imaging agent. J Nucl Med 16:28±32 Hovinga TKK, deJong PE, Piers DA, Beekhuis H, van-der Hem GK, de Zeeuw D (1989) Diagnostic use of angiotensin-converting enzyme inhibitors in radioisotope evaluation of unilateral renal artery stenosis. J Nucl Med 30:605±614 Ikeda I, Inoue O, Kurata, K (1976) Chemical and biological studies on 99mTc-DMSA-II: effect of Sn(II) on the formation of various Tc-DMSA complexes. Int J Appl Radiat Isot 27:681±688 Ikeda I, Inoue O, Kurata K (1977 a) Chemical and biological studies on 99mTc-DMSA-I: formation of complex by four different methods. Int. J Nucl Med Biol. 4:56±65
295
296
12.8
99m
Tc-Labeled Renal Imaging Agents
Ikeda I, Inoue O, Kurata K (1977 b) Preparation of various 99mTc-dimercaptosuccinate complexes and their evaluation as radiotracers. J Nucl Med 18:1222±1229 International Commission on Radiological Protection (1987) Technetium-DMSA. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol. 18, no.1±4. Pergamon, Oxford, pp 185±186 Johannsen B, Spies H, Syhre R (1979) Studies on complexation of 99mTc with dimercaptosuccinic acids with regard to organ specificity of 99mTc-radiopharmaceuticals. Eur J Nucl Med 4:148 Kopecky RT, McAfee JG, Thomas FD, Anderson HR Jr, Hellwig B, Roskopf M, Patchin D (1990) Enalaprilat-enhanced renography in a rat model of renovascular hypertension. J Nucl Med 31:501±507 Lange MJ de, Piers DA, Kosterink JGW, van Luijk WHJ, Meijer S, de Zeeuw D, van-der Hem GJ (1989) Renal handling of technetium-99m-DMSA: evidence for glomerular filtration and peritubular uptake. J Nucl Med 30:1219±1223 Lee HB, Blaufox MD (1985) Mechanism of renal concentration of technetium-99m glucoheptonate. J Nucl Med 26:1308±1313 Lin TH, Khentigam A, Winchell HS (1974) A 99mTc-chelate substitute for organoradiomercurial renal agents. J Nucl Med 15:34±35 Ohta H, Yamamoto K, Endo K, Mori T, Hamanaka D, Shimazu A, Ikekubo K, Makimoto K, Iida Y, Konishi J, Morita R, Hata N, Horiuchi K, Yokoyama A, Torizuka K, Kuma K (1984) A new agent for medullary carcinoma of the thyroid. J Nucl Med 25:323±325 Ramamoorthy N, Shetye SV, Pandey PM, Mani RS, Patel MC, Patel RB, Ramanathan P, Krishna BA, Sharma SM (1987) Preparation and evaluation of 99mTc(V)-DMSA complex: studies in medullary carcinoma of thyroid. Eur J Nucl Med 12:623±628 Saha GB (1997) Characteristics of specific radiopharmaceuticals. In: Fundamentals of nuclear pharmacy, 4th edn. Springer, Berlin Heidelberg New York, p 125 Taylor A Jr, Lallone RL, Hagan PL (1980) Optimal handling of dimercaptosuccinic acid for quantitative renal scanning. J Nucl Med 21:1190±1193 United States Pharmacopeial Convention (2005) Official Monographs: USP 28, technetium Tc-99m succimer injection. United States Pharmacopeia (USP) 28±national formulary (NF) 23, p 1864 Van Duzee BF, Bugaj JE (1981) The effect of total technetium concentration on the performance of a skeletal imaging agent. Clin Nucl Med 6(Suppl):148 Westera G, Gadze A, Horst W (1985) A convennient method for the preparation of 99mTc(V)DMSA. Int J Appl Radiat Isot 36:311±312 Yee CA, Lee HB, Blaufox MD (1981) 99mTc-DMSA renal uptake: influence of biochemical and physiologic factors. J Nucl Med 22:1054±1058
Chapter 12 Monographs of
12.8.2
99m
Tc Pharmaceuticals
99m
Tc-DPTA (Diethylenetriaminepentaacetate)
J. Kærnyei and I. Zolle Chemical structure
Chemical name Diethylenetriaminepentaacetate (DTPA) as Calcium trisodium salt Pentetate (Ph. Eur.; USP) Technetium Tc 99m pentetate injection (Ph. Eur.; USP) 99m
Pentetate
Tc-DTPA complex
Kit components
Commercial products
Amerscan Pentetate II:
Amerscan Pentetate II
GE Healthcare
Calcium trisodium diethylenetriaminepentaacetate 20.6 mg
TechneScan DTPA
Mallinckrodt/Tyco
Tin(II)-chloride dihydrate
0.25 mg
Sodium para-aminobenzoate
PentaCis (TCK-6)
CIS Bio
2 mg
DTPAScint
Bristol-Myers Squibb
DTPA
Rotop
TechneScan DTPA/Aerosol
Preparation The kit contains the lyophilized ingredients in a multidose vial. Labeling is performed by adding 2±10 ml of 99mTc eluate containing up to 11.1 GBq (300 mCi) under aseptic conditions. After sterile sodium 99mTc-pertechnetate has been added to the vial, the powder is dissolved by inverting the vial. The reaction is allowed to proceed at room temperature for 10±30 min. Kit composition varies between manufacturers; therefore, instructions should be followed. 99m Tc-diethylenetriaminepentaacetate (DTPA) complex is a sterile, pyrogen-free, clear, colorless solution suitable for intravenous injection. The pH should be between 4.0 and 7.5 (European Pharmacopeia [Ph. Eur.]).
Description of the Kit The 99mTc-DTPA complex for intravenous injection is used for renal studies (Atkins et al. 1971; Klopper et al. 1972). DTPA forms a negatively charged complex with reduced 99m Tc-technetium in neutral or weakly acidic solutions (Russel et al. 1980). The exact oxidation state is not known, although several valency states have been suggested (III± V). Quality control is essential when 99mTc-DTPA is used for the measurement of glomerular filtration rate (GFR), since commercial kits contain reduced, hydrolized 99mTc
297
298
12.8
99m
Tc-Labeled Renal Imaging Agents
activity as an impurity (Carlsen et al. 1988). Some formulations use gentisic acid as a stabilizer (Tofe et al. 1980). The 99mTc-DTPA complex may also be used as an aerosol; however, the kit composition suitable for nebulization differs from the renal agent. TechneScan DTPA/Aerosol contains 1.25 mg of DTPA and 0.12 mg tin(II)-chloride as dihydrate. Gentisic acid (0.25 mg) is used for stabilization. Labeling is performed by injecting less than 0.1 ml of 99mTc eluate, corresponding to at least 550 MBq (15 mCi) of radioactivity into the TechneScan DTPA/Aerosol vial, and then water for injection is added to obtain 1 ml of solution. After 15 min at room temperature, 0.5 ml of ethanol (98%) is added to the labeled product. The labeling yield is > 95%. The kit TechneScan DTPA/Aerosol must not be used for intravenous injection. 99m Tc-DTPA/Aerosol is a clear or slightly opalescent, aqueous solution, and the pH is 4.0±5.0. Fractionated elution of the generator is required to obtain a high activity concentration of 99mTc eluate for labeling. 99mTc eluate used for labeling should be obtained from a generator that is eluted daily (Van Duzee and Bugaj 1981). Not more than 0.5 ml (1,110 MBq; 30 mCi) of the labeled product should be used for nebulization (to deliver 150 MBq (4 mCi) to the lung). For inhalation of the 99mTc-DTPA complex, the vial is transferred to an aerosol generator. Ultrasonic nebulization of aqueous 99mTc-DTPA complex produces particles with an aerodynamic diameter of 0.5 lm (Wagner 1995).
Clinical Applications · · · · ·
Renal studies providing both anatomical and functional information Determination of the GFR Cerebral scintigraphy based on leaks in the blood±brain barrier (BBB) Localization of inflammatory bowel disease Inhalation scintigraphy to measure regional lung ventilation
Measurement of separate kidney function is particularly indicated for the management of unilateral and bilateral uropathy, staging of disease, assessment of unilateral compensatory hypertrophy, and in cases where x-ray examinations (intravenous pyelography, etc.) are contraindicated (Hilson et al. 1976; Nielsen et al. 1977; Russel 1985; Wassner 1981). 99m Tc-DTPA has been used for conventional cerebral scintigraphic studies for the detection of vascular and neoplastic brain lesions (Hauser et al. 1970). 99m Tc-DTPA accumulates in inflammatory lesions of the gastrointestinal tract and has been used for the detection of bleeding sites. An increase in tracer activity is seen almost immediately after bolus injection in the affected segments of bowel and persists for hours (Kadir and Strauss 1979). Inhalation scintigraphy using 99mTc-DTPA aerosol is performed for the assessment of pulmonary ventilation in patients with chronic obstructive lung disease (Coates and O'Brodovich 1986; Santolicandro and Giuntini 1979), and for the differential diagnosis of acute pulmonary embolism in combination with lung perfusion scintigraphy (Taplin and Chopra 1978; Wagner 1995). When inhaled, 99mTc-DTPA aerosol particles serve as an indicator of regional ventilation. Moist aerosols show a lung penetration between 1
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
and 10% of the nebulized activity. Labeled aerosols are also used to measure mucociliary clearance (Agnew 1991; Wanner 1977). Time of Examination Renal dynamic studies:
Collection of frames should start immediately after the intravenous injection. The total time for one examination is 30±60 min. Brain scintigraphy: 1±3 h after intravenous injection Abdominal images: Images are obtained at 5, 10, 15, and 25 min; in some patients, delayed images are obtained at intervals from 45 min± 4 h after the 99mTc-DTPA bolus Inhalation scintigraphy: This should start immediately after inhalation of the aerosol Recommended Activities for Indications Renal studies: 111±185 MBq (3±5 mCi) (7±20 mg DTPA) Brain scintigraphy: 300±500 MBq (8.1±13.5 mCi) (7±20 mg DTPA) Abdominal scintigraphy: 185±370 MBq (5±10 mCi) Inhalation scintigraphy: 150 MBq (4 mCi) inhaled radioactivity (nebulized activity 1,110 MBq resp., 30 mCi). Breathing time 3±5 min, with an oxygen supply of 7±10 l/min The manufacturer's instructions should be followed. Pediatric Dose. The amount of radioactivity for infants and children is based on either body weight (static imaging) or body surface area (dynamic examinations). Recommendations by the Pediatric Task Group of the European Association of Nuclear Medicine (EANM) based on body weight should be followed (see Appendix 1, Table A2.2).
Additional Information Free 99mTc-pertechnetate adds to increased background activity. Reduced, hydrolized 99m Tc activity is bound to plasma proteins in circulating blood, interfering with the measurement of plasma clearance (Rehling 1988). Therefore, quality control of 99mTcDTPA chelate should be performed before administration to patients. When 99mTcDTPA is used to measure GFR, it is necessary to remove the protein-bound impurity by passing the plasma through an ultrafilter before the measurement of radioactivity (Rowell et al. 1986). 99m Tc-DTPA is specific for the diagnosis of renal artery stenosis (Gruenewald and Collins 1983). Angiotensin-converting enzymes (ACE) inhibitors such as captopril reduce filtration pressure and thus cause a fall in GFR, as manifested by decreased renal uptake of 99mTc-DTPA. In patients who do not have renovascular hypertension, the GFR of each kidney is unchanged. Furosemide (Lasix) will enhance the detection of a dilated collecting system by rapid washout of the radiotracer from the pelvis and ureter, while in the case of urinary tract obstruction, no change of pelvic retention and in the shape of the time±activity curve is seen (O'Reilly 1992). The patient should be adequately hydrated before 99mTc-DTPA scintigraphy.
299
300
12.8
99m
Tc-Labeled Renal Imaging Agents
99m Tc-DTPA has been used for studies of gastroesophageal reflux and gastric emptying. In this case, scintigraphy is performed after oral administration of 99mTc-DTPA (10±20 MBq, 0.3±0.6 mCi) in a suitable liquid (300 ml), according to local practice. Sequential scintigraphy and static imaging may be performed. The patient's stomach is imaged at 5 and 10 min after drinking the liquid, and then every 5±15 min until the stomach activity has reached half the original value. The gastric emptying half-time is determined from a plot of percent activity versus time. Normal values are 10±15 min; delayed emptying is observed with gastric ulcers, pyloric stenosis, vagotomy, and in the case of malignancy (Chadhuri 1974).
Quality Control Radiochemical Purity. 99mTc-DTPA complex is described in the Ph. Eur. (Council of Europe 1997). Thin-layer chromatography (TLC) on silica gel (SG) fiberglass sheets in two different solvent systems is recommended for the separation of free 99mTc-pertechnetate and reduced, hydrolized 99mTc activity. · System I: Free 99mTc-pertechnetate is measured in methyl ethyl ketone (MEK) at the solvent front. · System II: Reduced, hydrolized 99mTc activity is separated in saline at the start. The radiochemical purity of 99mTc-DTPA chelate should not be less than 95% (Ph. Eur.). Thin-layer chromatography Sytem I (MEK)
Free
99m
Tc-pertechnetate at the solvent front
System II (Saline) Reduced, hydrolized 99m
(F)
99m
Tc activity at the origin
(H)
Tc-DTPA complex (%) = 100±%(F+H)
The Ph. Eur. states that the sum of measured impurities in both solvents must not exceed 5% of the total radioactivity. Reduced, hydrolized 99mTc activity should be analyzed before 99mTc-DTPA is used for GFR measurements: 99m
Tc-DTPA complex
% 100
F H
F (%) = 99mTc-Na-pertechnetate (free) H (%) = hydrolized 99mTc-activity. Results of analysis (12 samples) Results were obtained by thin-layer chromatography in two solvent systems, at different times after labeling. Labeling and stability
15 min (%)
6 h (%)
99m
98.5 Ô 0.27 0.6 Ô 0.12 0.8 Ô 0.06
97.2 Ô 0.32 0.8 Ô 0.25 1.0Ô 0.17
Tc-DTPA complex Tc-reduced, hydrolized Tc-Na-pertechnetate
99m 99m
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Pharmacokinetic Data After intravenous injection, 99mTc-DTPA penetrates capillary walls to enter the extravascular space within 4 min (McAfee et al. 1979). Because of its hydrophilicity and negative charge, 99mTc-DTPA is excluded from cells and is confined to the extracellular space. 99mTc-DTPA is removed from the circulation exclusively by the kidneys; renal clearance is unaffected by urine flow and by the administration of probenecid (Klopper et al. 1972). However, only the filtered fraction (20%) of the total renal plasma flow is excreted by glomerular filtration (Barbour et al. 1976). The plasma disappearance of 99mTc-DTPA can be described by a double exponential function (McAfee et al. 1979). One component (0.99) is excreted with a biological halftime of 100 min, the rest (0.01) with a half-time of 7 days. The fraction excreted by the kidneys is 1.0, and the renal transit time is 5 min. For abnormal cases, the retention half-time of the major component is increased (1,000 min) and so is the transit time (20 min). 99m Tc-DTPA cannot pass through the intact BBB, but in areas of the brain where structural defects permit diffusion, uptake has been used as an indicator of vascular and neoplastic brain lesions (Hauser et al. 1970). Inhalation of 99mTc-DTPA as an aerosol shows free diffusion of the particles (diameter of 0.5 lm) to the lung periphery and alveolar retention, larger droplets (> 1 lm) sediment preferentially in the trachea and upper bronchial tree (Coates and O'Brodovich 1986). In the lung, the label is released with a biological half-time of approximately 1 h. 99mTc-DTPA reaching the blood is excreted by the kidneys.
Radiation Dose The most exposed organs are the kidneys and bladder wall. The effective (whole body) dose equivalent is 0.0063 mSv/MBq (International Commission on Radiological Protection 1987 a). The effective dose in adults (70 kg) resulting from intravenous injection of 185 MBq (5 mCi) of 99mTc-DTPA complex is 1.2 mSv. Calculations of the absorbed radiation dose resulting from inhalation of 99mTcDTPA are based on technetium-labeled aerosols; it is assumed that the label is released fast, and that 99mTc-DTPA reaching the blood is excreted by the kidneys. The effective (whole body) dose equivalent is 0.007 mSv/MBq (International Commission on Radiological Protection 1987b). The effective dose in adults (70 kg) resulting from inhalation of 150 MBq (4 mCi) of 99mTc-DTPA is 1.05 mSv. The dose to the bladder wall after inhalation of 150 MBq (4 mCi) of 99mTc-DTPA is 7.0 mGy.
Storage and Stability Storage. The lyophilized kit is stored at 2±8 8C in the refrigerator. tion solution is kept at room temperature with adequate shielding. Stability. The
99m
99m
Tc-DTPA injec-
Tc-DTPA injection is stable within 6±8 h after preparation.
301
302
12.8
99m
Tc-Labeled Renal Imaging Agents
References Atkins HL, Eckelman WC, Hauser W, Klopper JF, Richards P (1971) Evaluation of glomerular filtration rate with 99mTc-DTPA. J Nucl Med 12:338 Agnew JE (1991) Characterizing lung aerosol penetration. J Aerosol Med 4:237±250 Barbour GL, Crumb CK, Boyd CM, Reeves RD, Rastogi SP, Patterson RM (1976) Comparison of inulin, iothalamate and Tc-99m-DTPA for measurement of glomerular filtration rate. J Nucl Med 17:317±320 Carlsen JE, Moller MH, Lund JO, Trap-Jensen J (1988) Comparison of four commercial Tc-99m(Sn)-DTPA preparations used for the measurement of glomerular filtration rate. J Nucl Med 21:126±129 Chadhuri TK (1974) Use of 99mTc-DTPA for measuring gastric emptying time. J Nucl Med 15:391±395 Coates G, O'Brodovich H (1986) Measurement of pulmonary epithelial permeability with 99mTcDTPA aerosol. Semin Nucl Med 16:275±284 Council of Europe (2005) Technetium 99mTc pentetate injection. European Pharmacopeia 5.0, monograph no 642. Council of Europe, Maisonneuve, Sainte-Ruffine, pp 1223 Gruenewald SM, Collins LT (1983) Renovascular hypertension: quantitative renography as a screening test. Radiology 149:287±291 Hauser W, Atkins HL, Nelson KG, Richards P (1970) Technetium-99m-DTPA: a new radiopharmaceutical for brain and kidney scanning. Radiology. 94:679±684 Hilson AJW, Mistry RD, Maisey MN (1976) Tc-99m-DTPA for the measurement of glomerular filtration rate. Br J Radiol 49:794±796 International Commission on Radiological Protection (1987a) Technetium-DTPA. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, pp 187±190 International Commission on Radiological Protection (1987b) Technetium-labelled aerosols. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, pp 217±219 Kadir S, Strauss WH (1979) Evaluation of inflammatory bowel disease with Tc-99m-DTPA. Radiology 130:443±446 Klopper JF, Hauser W, Atkins HL, Eckelman WC, Richards P (1972) Evaluation of Tc-99m-DTPA for the measurement of glomerular filtration rate, J Nucl Med 13:107±110 McAfee JG, Gagne G, Atkins HL, Kirchner PT, Reba RC, Blaufox MD, Smith EM (1979) Biological distribution and excretion of DTPA labeled with Tc-99m and In-111. J Nucl Med 20:1273±1278 Nielsen SP, Moller ML, Trap-Jensen J (1977) Tc-99m-DTPA scintillation-camera renography: a new method for estimation of single-kidney function, J Nucl Med 18:112±117 O'Reilly PH (1992) Diuresis renography. Recent advances and recommended protocols. Br J Urol 69:113±120 Rehling M (1988) Stability, protein binding and clearance studies of 99mTc-DTPA. Evaluation of a commercially available dry-kit. Scand J Clin Lab Invest 48:603±609 Rowell KL, Kontzen FK, Stutzman ME, Caranto R, Barber JM, Russel CD, Dubovsky EV, Scott JW (1986) Technical aspects of a new technique for estimating glomerular filtration rate using Technetium-99m-DTPA. J Nucl Med Tech 14:196±198 Russell CD (1985) Radiopharmaceuticals used to assess kidney function and structure. Tauxe WN, Dubovsky EV (eds) Nuclear medicine in clinical urology and nephrology. Appleton-CenturyCrofts, Norwalk, Conn., pp 7±31 Russel CD, Crittenden RC, Cash AG (1980) Determination of net ionic charge on Tc-99m-DTPA and Tc-99m-EDTA by a column ion-exchange method. J Nucl Med 21:354±360 Santolicandro A, Giuntini C (1979) Patterns of deposition of labeled monodispersed aerosols in obstructive lung disease. J Nucl Med All Sci 23:115 Taplin GV, Chopra SK (1978) Lung perfusion-inhalation scintigraphy in obstructive airway disease and pulmonary embolism. Radiol Clin N Am 16:491±513 Tofe AJ, Bevan JA, Fawzi MB, Francis MD, Silberstein EB, Alexander GA, Gunderson DE, Blair K (1980) Gentisic acid: a new stabilizer for low tin skeletal imaging agents. Concise communication. J Nucl Med 21:366±370 United States Pharmacopeial Convention (2005) Official Monographs: USB 28, technetium Tc-99m pentetate injection. United States Pharmacopeia (USP) 28±national formulary (NF) 23, p 1860 Van Duzee BF, Bugaj JE (1981) The effect of total technetium concentration on the performance of a skeletal imaging agent. Clin Nucl Med 6(Suppl):148
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Wagner HN Jr (1995) Regional ventilation and perfusion. In: Wagner HN Jr, Szabo S, Buchanan JW (eds) Principles of nuclear medicine, 2nd edn. Saunders, Philadelphia, pp 887±895 Wanner A (1977) Clinical aspects of mucociliary transport. Amer Rev Respir Dis 116:73±125 Wassner SJ (1981) Assessment of glomerular filtration rate using single injection of technetium Tc-99m pentetate. Am J Dis Child 135:374±375
12.8.3
99m
Tc-EC (Ethylene Dicysteine)
J. Kærnyei Chemical name
Chemical structure
N,N-Ethylene-L,L-dicysteine (L,L-EC) Tc(V)oxo-N,N-ethylene dicysteine Technetium-99m ethylenedicysteine 99m
Tc(V)-L,L-ethylenedicysteine (EC)
99m
Tc-L,L-EC complex
Tc(V)oxo-L,L-EC
Kit components
Kit components
Vial A:
Vial B:
N,N,-Ethylene-L,L-dicysteine
2.0 mg
Stannous chloride dihydrate
0.2 mg
Ascorbic acid
0.5 mg
Tartaric acid
48 mg
Sodium-ethylenediamine tetraacetic acid (EDTA)
0.35 mg
Ascorbic acid
12 mg
Disodium hydrogen phosphate
13.3 mg
Mannitol
30 mg
Vial C: Stannous chloride dihydrate
Commercial products EC in vivo kit Institute of Isotopes (Hu) (Kit is registered in Hungary)
0.2 mg
Potassium dihydrogen phosphate
18.2 mg
Ascorbic acid
12 mg
Preparation One kit consists of three vials, A, B, and C, containing the lyophilized ingredients. Labeling is performed under aseptic conditions as follows. Procedure: · Inject into vial A sufficient 99mTc activity (0.8±1.6 GBq; resp., 22-43 mCi) in a volume of 2.0 ml. · Dissolve the content of vial B in 2.0 ml saline. After dissolution, withdraw 0.5 ml and inject into vial A. The resulting pH should not be below 12.0.
303
304
12.8
99m
Tc-Labeled Renal Imaging Agents
· Let react for 15 min at room temperature. · Dissolve the content of vial C in 1.0 ml saline and transfer this solution to vial A. 99m
Tc-EC complex is a sterile, pyrogen-free, clear, colorless solution suitable for intravenous injection. The pH value is 5.5±8.0. 99mTc-EC injection solution should be used within 3 h after labeling.
Description of the Kit Vial A contains 2 mg of lyophilized ethylene-l,l-dicysteine (l,l-EC) and several reagents to facilitate labeling with 99mTc-pertechnetate at alkaline pH. The eluate should be fresh, preferably obtained from a 99Mo/99mTc generator eluted regularly, every 24 h. If necessary, the appropriate radioactivity concentration is adjusted with 0.9% NaCl solution for injection. Labeling is initiated by the addition of 0.5 ml of reducing agent containing 50 lg of stannous chloride from vial B. After 15 min incubation at room temperature, 1 ml of the buffer solution containing ascorbic acid as a stabilizer is added from vial C. Vial A contains 3.5 ml of 99mTc-EC injection solution suitable for not less than 3 patient doses. The original kit composition reported by Verbruggen et al. (1992) consisted of the lyophilized residue of a solution of 0.5 mg of l,l-EC and 0.1 mg of stannous chloride dihydrate in 1 ml of phosphate buffer (0.05 M, pH 12.0). Labeling was performed by adding 1.850 MBq 99mTc-pertechnetate in a volume of 5 ml to the reaction vial. After incubation for at least 1 min at room temperature, the pH was adjusted with 0.2 ml of 0.5 M phosphate buffer (pH 5). The final pH of 99mTc-EC injection solution was 7.0± 8.0; the complex was stable for 8 h. The advantage of this formulation is high specific activity labeling, keeping the amount of injected ligand below 15 lg (Stoffel et al. 1994). At alkaline pH, an N2S2 complex is formed with the EC-ligand and pentavalent technetium, having a TcO core and two carboxylate functions. After neutralization, 99mTcEC is a negatively charged complex with the chemical formula [TcO EC]±1.
Clinical Applications · Dynamic studies providing information on renal function (camera renography) · Determination of the tubular extraction rate (TER) · Examination of renal function in patients with transplanted kidneys Since the introduction of 99mTc-l,l-EC as a tubular radiotracer (Verbruggen et al. 1992), clinical verification of the pharmacokinetic parameters has been obtained in normal controls (Van Nerom et al. 1993) and in patients (Gupta et al. 1995; Kabasakal et al. 1995), using standard procedures and also by comparison with the reference compounds ortho-iodohippurate (OIH) labeled with iodine-125 and with 99mTc-mercaptoacetyltriglycine (MAG3) (Kabasakal et al. 1995; Úzker et al. 1994; Stoffel et al. 1996). 99m Tc-EC complex showed high similarity with OIH with respect to plasma clearance and elimination half-times (Úzker et al. 1994; Van Nerom et al. 1993). 99mTc-EC was
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
also evaluated for the diagnosis of renal artery stenosis in patients with suspected renovascular hypertension (Kibar et al. 1997). Time of Examination Dynamic renal studies: Collection of frames should start immediately after the intravenous injection of 99mTc-EC. The total time for one examination is approximately 20 min. Recommended Activities for Indications Dynamic renal studies: 90±120 MBq (2.4±3.2 mCi), injected intravenously 0.3±0.7 mg of 99mTc-EC complex The manufacturer's instructions should be followed. Pediatric Dose. The amount of radioactivity for infants and children is based on either body weight (static imaging) or body surface area (dynamic examinations). Recommendations by the Pediatric Task Group of the European Association of Nuclear Medicine (EANM) based on body weight should be followed (see Appendix 1, Table A1.2).
Additional Information The patient should be adequately hydrated before 99mTc-EC renography. Certain medication may affect renal clearance even in patients with normal kidney function. Slower washout is observed with angiotensin-converting enzymes (ACE) inhibitors. Tubular secretion is affected by the administered amount of 99mTc-EC. The single dose should not exceed 0.7 mg of EC (use kit for three patients), since secretion may be delayed; in cases of impaired renal function, a saturation effect may be observed. Higher doses (entire kit content) should be avoided since the diagnostic value of the renal examination may be biased. 99m Tc-EC complex does not contribute to hepatobiliary activity; thus, 99mTc-EC is especially suited for the examination of renal function in patients with kidney transplants.
Quality Control Radiochemical Purity. The radiochemical purity of the 99mTc-EC complex is measured by thin-layer chromatography (TLC), using one solvent system to separate 99mTc-pertechnetate (SF) and reduced 99mTc activity (start) from the 99mTc-EC complex (a more rapid analysis using two solvent systems has been described by Stoffel et al. 1994). The radiochemical purity of the 99mTc-EC complex should not be less than 95%.
305
306
12.8
99m
Tc-Labeled Renal Imaging Agents
Method Recommended by the Manufacturer Thin-layer chromatography Stationary phase: Solvent: Developing time:
Gelman ITLC SG-60 plates 1.5 ´ 20 cm 96% Ethanol 2.5 h (A more rapid analysis using 2 solvent systems has been described by Stoffel et al. [1994].)
Rf values:
99m
Tc reduced, hydrolized: 0.0±0.1 Tc-EC complex: 0.45±0.55 (> 95%) 99m Tc-Na-pertechnetate: 0.9±1.0 99m
The limit of radiochemical impurities at expiry (3 h) is <10%. Results of analysis (12 samples) Labeling and stability
15 min (%)
3 h (%)
99m
98.7 Ô 0.65 < 0.3 < 1.0
99.4 Ô 0.2 < 0.2 < 0.4
Tc-EC complex Tc-Na-pertechnetate 99m Tc-reduced, hydrolized 99m
Pharmacokinetic Data The elimination of the 99mTc-l,l-EC complex from the blood is rapid. At 2±3 min postinjection, no heart and liver activities (due to perfusion) are observed. This is in agreement with the protein binding data of 99mTc-EC (31%) (Van Nerom et al. 1993), which is considerably less than of 123I-OIH (74.1 Ô 3.9%) and approximately 30% of 99mTcMAG3 (91.3 Ô 1.9%) (Bubeck et al. 1990). 99m Tc-EC is excreted by tubular secretion in the kidneys; the TER is 69±75% of the reference para-amino-hippurate (PAH). The maximum of radioactivity in the kidneys is observed at 4.4 Ô 0.3 min after intravenous injection. The washout of 99mTc-EC is rapid but slightly slower than of OIH, indicated by the biological half-times of 99mTcEC 6.3±7.6 min and OIH 4.7±6.3 min (Úzker et al. 1994). A comparison of 99mTc-l,l-EC with 125I-OIH in normal volunteers and in a wide range of renal function values has produced data of the mean plasma clearance with a close correlation between 99mTc-l,l-EC and 125I-OIH (r = 0.99, p < 0.001). The mean clearance of 99mTc-l,l-EC amounted to 70.6 Ô 6.2% of the 125I-OIH clearance with a range of 34.7±103.8% (Stoffel et al. 1994). The total volume of distribution of both tracers was not significantly different, corresponding to approximately 20% of the body weight. When 99mTc-EC was compared with 99mTc-MAG3, it showed a higher plasma clearance and considerably lower activity in the liver; there was no significant activity in bowel and gallbladder even in patients with impaired kidney function (Verbruggen et al. 1992).
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Radiation Dose Kidneys, bladder wall, and adrenals are most exposed organs. Calculations of the effective dose are based on dose equivalents for technetium-MAG3 (International Commission on Radiological Protection 1991). Depending on the functional state of the kidneys the effective dose (mSv/MBq) is given as: Normal function: 0.0073 Abnormal function: 0.0063 Acute unilateral: 0.01 Accordingly, the effective (whole body) dose resulting from 111 MBq of intravenously injected 99mTc-EC complex is 0.81 mSv (normal function), 0.70 mSv (abnormal function), and 1.11 mSv (acute unilateral obstruction).
Storage and Stability Storage. The lyophilized kit is stored at 2±8 8C in the refrigerator. solution is kept at room temperature with adequate shielding.
99m
Tc-EC injection
Stability. The 99mTc-EC injection solution is stable for 3 or 8 h after preparation, depending on the kit formulation.
References Bubeck B, Brandau W, Weber E, Kaelble T, Parekh N, Georgi P (1990) Pharmacokinetics of technetium-99m-MAG3 in humans. J Nucl Med 31:1285±1293 Gupta NK, Bomanji JB, Waddington W, Lui D, Costa DC, Verbruggen AM, Ell PJ (1995) Technetium-99m-l,l-ethylenedicysteine scintigraphy in patients with renal disorders. Eur J Nucl Med 22:617±624 International Commission on Radiological Protection (1991) Technetium-labeled mercaptoacetyltriglycine (MAG3) In: Annals of the ICRP, radiological protection in biomedical research. ICRP publication 62, vol. 22, no. 3. Pergamon, Oxford, pp 15±19 Kabasakal L, Atay S, Vural VA, Úzker K, Sænmezoglu K, Demir M, Uslu I, Isitman AT, Únsel C (1995) Evaluation of technetium-99m-ethylenedicysteine in renal disorders and determination of extraction ratio. J Nucl Med 36:1398±1403 Kabasakal L, Turoglu HT, Únsel C, Úzker K, Uslu I, Atay S, Cansiz T, Sænmezoglu K, Altiok E, Isitman AT, Kapicioglu T, Urgancioglu I (1995) Clinical comparsion of technetium-99m-l,l-EC, technetium-99m-MAG3 and iodine-125-OIH in renal disorders. J Nucl Med 36:224±228 Kibar M, Tutus A, Paydas S, Reyhan M (1997) Captopril-enhanced technetium-99m-l,l-ethylenedicysteine renal scintigraphy in patients with suspected renovascular hypertension: comparative study with Tc-99m-MAG3. J Nucl Med 6:132±137 Úzker K, Únsel C, Kabasakal L, Sayman HB, Uslu I, Bozluolcay S, Cansiz T, Kapicioglu T, Urgancioglu I (1994) Technetium-99m l,l-ethylenedicysteine: a comparative study of renal scintigraphy with Tc-99m-MAG-3 and I-131-OIH in patients with obstructive renal disease. J Nucl Med 35:840±845 Stoffel M, Jamar F, Van Nerom C, Verbruggen AM, Mourad M, Leners N, Squifflet JP, Beckers C (1994) Evaluation of technetium-99m-l,l-EC in renal transplant recipients: comparative study with technetium-99m-MAG3 and iodine-125-OIH. J Nucl Med 35:1951±1958
307
308
12.8
99m
Tc-Labeled Renal Imaging Agents
Stoffel M, Jamar F, Van Nerom C, Verbruggen AM, Besse T, Squifflet JP, Beckers C (1996) Technetium-99m-l,l-ethylenedicysteine clearance and correlation with iodine-125 ortho-iodohippurate for determination of effective renal plasma flow. Eur J Nucl Med 23:365±370 Van Nerom CG, Bormans GM, De Roo MJ, Verbruggen AM (1993) First experience in healthy volunteers with technetium-99m l,l-ethylenedicysteine, a new renal imaging agent. Eur. J Nucl Med 20:738±746 Verbruggen AM, Nosco DL, Van Nerom CG, Bormans GM, Adriaens PJ, De Roo MJ (1992) Technetium-99m-l,l-ethylenedicysteine: a renal imaging agent. I. Labeling and evaluation in animals. J Nucl Med 33:551±557
12.8.4
99m
Tc-MAG3 (Mercaptoacetyltriglycine)
F. Rakis and I. Zolle Chemical structure
Chemical name Benzoylmercapto-acetyltriglycine: Betiatide (Ph. Eur.; USP) Tc(V)oxo-N,N,N-mercaptoacetyltriglycine: Mertiatide (Ph. Eur.; USP) Technetium Tc 99m mertiatide injection (Ph. Eur.; USP) 99m
Tc(V)O-mercaptoacetyltriglycine complex
99m
99m
Tc(V)-MAG3 complex
Tc-MAG3 complex
Kit components Betiatide
Commercial products 1.0 mg
TechneScan MAG3
Mallinckrodt/Tyco
Stannous chloride dehydrate 0.04 mg Disodium tartrate
16.9 mg
Preparation The kit contains the lyophilized, sterile, pyrogen-free, inactive ingredients in a nitrogen atmosphere, ready for labeling with 99mTc-sodium pertecnetate (European Pharmacopeia [Ph. Eur.]). Labeling is performed according to the instructions given by the manufacturer (Mallinckrodt 1992): · Method 1: Use 3 ml of fresh eluate; the activity should not exceed 1.11 GBq (30 mCi). The calculated amount of 99mTc activity is diluted to a volume of 10 ml with saline. Add this volume to a TechneScan mercaptoacetyltriglycine (MAG3) vial, using a thin hypodermic needle (20 gauge or higher). Place the kit in upright position into a boiling water bath for 10 min. After heating, cool the vial in cold water. 99m Tc-MAG3 injection solution (10 ml) is stable for 4 h.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
· Method 2: To obtain higher activity concentrations, use 1 ml of fresh eluate for labeling and dilute to 4 ml with saline. The activity should not exceed 925 MBq (25 mCi). Follow the procedure as described above. This preparation (4 ml) is stable for 1 h. 99m
Tc-MAG3 is a clear or slightly opalescent, colorless, sterile solution for intravenous injection. The resulting pH should be 5.0±7.5. 99mTc-MAG3 injection solution may be used for one or multiple administrations.
Description of the Kit 99m
Tc-mertiatide is obtained upon heating in a boiling water bath with a labeling yield of approximately 96%. One molecule of S-benzoyl-protected betiatide reacts with reduced 99mTc in the + 5 oxidation state to form a negatively charged 99mTc-MAG3 complex. Initially, at pH 5.5, a labile 99mTc-tartrate complex is formed, which is readily exchanged by the benzoylmercaptoacetyl triglycine ligand during heating at 95 8C (ligand exchange). Heating in a boiling water bath is required, because at room temperature formation of the 99mTc-MAG3 complex is slow (52% in 2 h) (Fritzberg et al. 1986). The heating process also increases the rate of hydrolysis of the protecting benzoyl group and the conversion of a bis ligand complex, which may also be formed, to single-ligand 99m Tc-MAG3. The core ligand system N3S and an additional carboxylate group are responsible for high tubular specificity and a high excretion rate. In addition, the triamide monomercaptide ligand does not form stereoisomers that required high-performance liquid chromatography (HPLC) purification (Fritzberg et al. 1986). 99mTc-MAG3 is a tetradentate chelate of oxotechnetium as described for the TcON2S2 N,N-bis(mercaptoacetyl) ethylenediamine (DADS) ligands (Davison et al. 1981). The effect of stereoisomers and of byproducts on kit preparation has been investigated extensively (Brandau et al. 1988 a, b; Bubeck et al. 1986; Coveney and Robbins 1987; Fritzberg et al. 1982). Labeling should be performed with eluates with the highest possible radioactive concentration. In order to obtain a high yield and to avoid labeled impurities, the 99m Tc eluate used for labeling must be obtained from a 99mTc generator that is eluted daily at a 24-h interval (Van Duzee and Bugaj 1981). Moreover, only eluates from a 99m Tc generator that has been in use for no longer than 5 days are suitable. Dilutions should be performed with saline.
Clinical Applications Intravenous injection: Renal imaging/renography · To obtain anatomical and functional information · To demonstrate adequate renal perfusion · To evaluate renal tubular function · To determine the tubular extraction rate (TER) · As a control after surgical intervention (kidney transplants) · To evaluate renal artery stenosis and obstructive uropathy · To diagnose urinary obstruction in infants
309
310
12.8
99m
Tc-Labeled Renal Imaging Agents
The similarity of 99mTc-MAG3 with 131I-OIH (o-iodohippurate) has been demonstrated in experimental animals (Fritzberg et al. 1986) and in volunteers (Taylor et al. 1986). Since glomerular filtration accounts for less than 2% of the total clearance, 99mTcMAG3 has been recommended for determination of the TER (Bubeck et al. 1987, 1990). 99m Tc-MAG3 is used for the evaluation of nephrological and urological disorders, in particular for the study of renal perfusion, relative kidney function, and characterization of urinary flow. Renovascular hypertension is diagnosed after pharmacological intervention (captopril test) (Kletter 1988). Time of Examination Renal dynamic studies:
Collection of frames should start immediately after the intravenous injection of. The total time for one examination is approximately 20 min.
Recommended Activities for Indications Renal clearance (plasma clearance): 10±20 MBq (0.27±0.54 mCi) Renography: 60±80 MBq (1.6±2.2 mCi) Functional scintigraphy: 150±200 MBq (4±5 mCi), 0.3±1 mg of 99mTc-MAG3 100 MBq (2.7 mCi) maximum recommended activity (Administration of Radioactive Substances Advisory Committee [ARSAC]) Depending on the parameters to be studied and the method to be used, 37±185 MBq (1±5 mCi) are used in adults (70 kg). Studies of renal blood flow or transport through the ureters generally require a larger dose than do studies of intrarenal transport; whereas renography requires smaller activities than dynamic sequential scintigraphy. Pediatric Dose. The amount of radioactivity for infants and children is based on either body weight (static imaging) or body surface area (dynamic examinations). Recommendations by the Pediatric Task Group of the European Association of Nuclear Medicine (EANM) based on body weight should be followed (see Appendix 1, Table A1.2).
Additional Information The patient should be adequately hydrated before injecting 99mTc-MAG3. Insufficient hydration of the patient will affect the renal excretion rate. In order to reduce the radiation exposure to the bladder wall, the patient should be asked to drink water during the following hours. Small amounts of 99mTc-labeled impurities may be formed during the labeling process, which accumulate in the liver and contribute to hepatobiliary activity. Dynamic renal studies may be affected in the late phase (after 30 min) due to an overlap of activity in the region of interest. ACE inhibitors such as captopril may facilitate the differential diagnosis of renovascular hypertension; diuretics such as furosemide (Lasix) cause rapid washout of the radiotracer or demonstrate urinary tract obstruction (Kletter 1988).
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Quality Control Radiochemical Purity. The Ph. Eur. (Council of Europe 2005) requires paper chromatography using acetonitrile/water (60 : 40, v/v) to determine reduced, hydrolized technetium at the start, which should not exceed 2% of the measured radioactivity. For identification of 99mTc-mertiatide and 99mTc-Na-pertechnetate, high performance liquid chromatography (HPLC) is recommended. The radiochemical purity of the 99mTcMAG3 complex should not be less than 94%. HPLC method Gradient elution for the simultaneous determination of free 99mTc-pertechnetate and 99m Tc-mertiatide. · The column is a Merck octadecylsilyl-silica (5 lm), 25 cm ´ 4 mm · Flow rate is 1.0 ml/min · Mobile phase A is a 19 : 1 mixture of phosphate solution (1000 parts 0.01 M NaH2PO4 and 114 parts 0.01 M Na2HPO4, adjusted to pH 6.0) and ethanol. · Mobile phase B is a 1 : 9 mixture of water and methanol. · Inject 20 ll of the test solution into the chromatograph and record the chromatograms by gradient elution. Use a gradient elution program. · Retention times: 99mTc-pertechnetate, 1.8±2.2 min; 99mTc-mertiatide, 10±14 min Requirements (Ph. Eur.). The sum of activities eluted before the major peak activity (hydrophilic impurities including 99mTc-pertechnetate) should not exceed 3% of the sum of all peaks, and the sum of activities eluted after the major peak activity (lipophilic impurities) should not be more than 4% of the sum of all peaks. The radiochemical purity of the 99mTc-MAG3 complex should not be less than 94%. Results of HPLC analysis of the 99mTc-MAG3 complex, performed at different times after preparation: Eluted peak activity
TOC (%)
4 h (%)
Mertiatide Total front fractions Methanol fraction
³ 96.0 £ 3.0 £ 4.0
³ 95.0 £ 3.0 £ 4.0
Methods Recommended by the Manufacturer. Thin-layer chromatography (TLC) on silica gel reversed phase plates (migration distance 10±15 cm) and acidified methanolsaline is used as solvent for the analysis of three components, namely the 99mTc-MAG3 complex (Rf = 0.4±0.5); reduced, hydrolized technetium at the start; and unbound 99m Tc-Na-pertechnetate at the solvent front. The radiochemical purity of the 99mTcMAG3 complex should not be less than 90%. Thin-layer chromatography Stationary phase: Solvent: Developing time:
Merck RP-18 F254 plates, 1.5 ´ 20 cm Methanol/saline/acetic acid (45 : 54 : 1, v/v/v) 1.5 h
Rf values:
99m
Tc-reduced, hydrolized: Tc-mertiatide: Tc-Na-pertechnetate:
99m 99m
0.0±0.1 0.4±0.5 (> 90%) 0.9±1.0
311
312
12.8
99m
Tc-Labeled Renal Imaging Agents
Quantification of labeled components. Each chromatogram is measured (TLC linear analyzer, or gamma counter) and the regional radioactivities are expressed as a percentage of the total recovered counts. Results of analysis (12 samples): Labeling and stability
15 min (%)
3 h (%)
99m
98.3 Ô 0.30 1.0 Ô 0.45 0.6 Ô 0.27
96.2 Ô 0.34 1.0 Ô 0.39 2.7 Ô 0.54
Tc-MAG3 complex Tc-Na-pertechnetate Tc reduced, hydrolized
99m 99m
Column chromatography. This method is based on the extraction by Sep-Pak C18 cartridges (Waters, light) and elution with 50% ethanol/saline. Procedure: 1. Rinse the cartridge first with 5 ml ethanol, and then with 5 ml 0.001 N hydrochloric acid. 2. Mix 5 ml ethanol and 5 ml saline. 3. Apply 0.1±0.3 ml of the 99mTc-MAG3 injection solution onto the column. 4. Rinse the column with 5 ml 0.001 N HCl into vial A. 5. Elute cartridge with 5 ml of ethanol/saline into vial B. Vials A and B and the eluted cartridge are measured for brator. Use the sum of eluted radioactivities as 100%: 99m
Tc-MAG3 complex
%
The radiochemical purity of
99m
Tc activity in a dose cali-
B 100 Sum of A B SEP-PAK
99m
Tc-mertiatide should not be less than 90%.
Pharmacokinetic Data After intravenous injection, 99mTc-mertiatide is rapidly distributed in the extracellular fluid and excreted entirely by the renal system. The maximum renal accumulation of radioactivity is observed at 3±4 min (207 Ô 80 s) after intravenous injection (Taylor et al. 1986). The elimination from plasma is described by two half-times, namely, 3.2 and 16.9 min. The mean parenchymal transit time is approximately 4 min (100±270 s) (Jafri et al. 1988). At 3 h postinjection the activity in blood is less than 1% of the injected dose. Urinary excretion of 99mTc-MAG3 is 70% in 30 min (normal renal function), and 99.9 Ô 4.3% at three h postinjection. 99mTc-MAG3 is not metabolized and is excreted unchanged (Taylor et al. 1986). The mechanism of excretion is predominantly based on renal tubular secretion. The TER of 99mTc-MAG3 is 0.55 of the reference para-amino-hippurate ([PAH] 1.0); in comparison, ortho-iodohippurate (OIH) shows a value of 0.83 (Bubeck et al. 1987). Using this coefficient (0.55), 99mTc-MAG3 may substitute for OIH as an indicator of effective renal plasma flow (ERPF) (Bubeck et al. 1990).
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
The renal clearance is dependent on the functional state of the kidneys and the urogenital system; however, there is a good correlation between the clearance of 99mTc-MAG3 and 131 I-OIH in patients with seriously impaired renal function or transplant kidneys as well as in patients with normal tubular function (Bubeck et al. 1988c). Simultaneously obtained clearance data showed striking differences between plasma clearance and plasma concentration. The plasma clearance of 99mTc-MAG3 was about one half that of 131IOIH, but its plasma concentration was much higher in concordance with the high protein binding; the net effect being a similar urinary excretion and qualitatively similar renogram curves (Russel et al. 1988). Using a two-compartment model, Taylor et al. (1986) reported a 99mTc-MAG3/OIH plasma-clearance ratio of 0.69 during the first 30 min postinjection, and Bubeck et al. (1990) at steady state a ratio of 0.67. 99m Tc-mertiatide shows high binding to plasma proteins (91.3 Ô 1.9%). Glomerular filtration accounts for less than 2% of the total clearance (Bubeck et al. 1987, 1990).
Radiation Dose The kidneys, bladder wall, and adrenals are most exposed organs. MAG3 is rapidly distributed in the extracellular fluid and excreted entirely by the renal system. The renal transit time is approximately 4 min, as is for OIH (Bubeck et al. 1987). Calculations of the effective dose are based on dose equivalents for technetiumMAG3 (International Commission on Radiological Protection 1991). Depending on the functional state of the kidneys the effective dose (mSv/MBq) is given as: · Normal function: 0.0073 · Abnormal function: 0.0063 · Acute unilateral blockage: 0.01 Accordingly, the effective (whole body) dose resulting from 100 MBq (2.7 mCi) of intravenously injected 99mTc-MAG3 complex is 0.73 mSv (normal function), 0.63 mSv (abnormal function), and 1.0 mSv (acute unilateral obstruction). The doses resulting from 100 MBq (2.7 mCi) to exposed organs (mGy) are: · Bladder 11.0, kidneys 0.34, uterus 1.2 (normal function) · Bladder 8.3, kidneys 1.4, uterus 1.0 (abnormal function) · Adrenals 1.1, bladder 5.6, kidneys 20.0 (acute, unilateral obstruction) When renal function is bilaterally impaired, it is assumed that the clearance rate of MAG3 is one tenth of that for the normal case, the renal transit time is increased to 20 min, and a fraction of 0.04 is taken up in the liver. In the case of acute unilateral renal blockage, it is assumed that a fraction of 0.5 of administered MAG3 is taken up by one kidney and slowly released to the blood with a half-time of 5 days, and subsequently excreted by the other kidney, which is assumed to function normally (International Commission on Radiological Protection 1991). Unilateral renal blockage causes a shift in the excretion pattern, with the highest radiation absorbed dose delivered to the kidneys, namely, 0.20 mGy/MBq. Consequently, the effective (whole body) dose value is 0.01 mSv/MBq, and the effective dose in adults (70 kg) resulting from intravenous injection of 150 MBq (4 mCi) of 99m Tc-MAG3 complex is 1.5 mSv.
313
314
12.8
99m
Tc-Labeled Renal Imaging Agents
Storage and Stability Storage. The TecneScan MAG3 kit is stored at 2±8 8C, protected from light until use. 99m Tc-MAG3 injection solution is kept at room temperature with adequate shielding. Stability. 99mTc-MAG3 injection is stable for 1 or 4 h after labeling, depending on the volume of preparation (4 or 10 ml). If the injection solution is used for multiple administrations, the vial should be kept in the refrigerator.
References Bubeck B, Brandau W, Dreikorn K, Steinbåcher M, Eisenhut M, Trojan H, zum Winkel K (1986) Clinical comparison of I-131 o-iodohippurate with Tc-99m-CO2-DADS-A and Tc-99m-MAG3 by simultaneous double tracer measurement. Nucl Compact 17:135±138 Bubeck B, Brandau W, Eisenhut M, Weidenhammer K, Georgi P (1987) The tubular extraction rate (TER) of Tc-99m-MAG3: a new quantitative parameter of renal function. Nuc Compact 18:260±267 Brandau W, Bubeck B, Eisenhut M, Taylor DM (1988a) Technetium-99m labeled renal function and imaging agents: III. Synthesis of Tc-99m-MAG3 and biodistribution of by-products. Appl Radiat Isot 39:121±129 Bubeck B, Brandau W, Reinbold F, Dreikorn K, Steinbåcher M, Eisenhut M, Georgi P (1988b) Technetium-99m labeled renal function and imaging agents: I clinical evaluation of Tc-99m-CO2DADS-A (Tc-99m-N,N-bis-(mercapto-acetyl)-2,3-diamino-propanoate). Nucl Med Biol 15:99± 108 Bubeck B, Brandau W, Steinbåcher M, Reinbold F, Dreikorn K, Eisenhut M, Georgi P (1988c) Technetium-99m labeled renal function and imaging agents: II. Clinical evaluation of 99mTc-MAG3 (99mTc-mercaptoacetylglycylglycylglycine). Nucl Med Biol 15:109±118 Bubeck B, Brandau W, Weber E, Kaelble T, Parekh N, Georgi P (1990) Pharmacokinetics of technetium-99m-MAG3 in humans. J Nucl Med 31:1285±1293 Council of Europe (2005) Technetium 99mTc mertiatide injection. European pharmacopeia 5.0, monograph no 1372. Council of Europe, Maisonneuve, Sainte-Ruffine, pp 1220 Coveney JR, Robbins MS (1987) Comparison of technetium-99m MAG3 kit with HPLC-purified technetium-99m MAG3 and OIH in rats. J Nucl Med 28:1881±1887 Davison A, Jones A, Orvig C, Sohn M (1981) A new class of oxotechnetium (+5) chelate complexes containing a TcON2S2 core. Inorg Chem 20:1629±1632 Fritzberg AR, Kuni CC, Klingensmith WC III, Stevens J, Whitney WP (1982) Synthesis and biological evaluation of Tc-99m N,N-bis (mercaptoacetyl)-2,3-diaminopropanoate: a potential replacement for [131I]-o-iodohippurate, J Nucl Med 23:592±598 Fritzberg AR, Kasina S, Eshima D, Johnson DL (1986) Synthesis and biological evaluation of technetium-99m-MAG3 as a hippuran replacement. J Nucl Med 27:111±116 International Commission on Radiological Protection (1991) Technetium-labelled mercaptoacetyltriglycine (MAG3) In: Annals of the ICRP, radiological protection in biomedical research. ICRP publication 62, vol 22, no 3. Pergamon, Oxford, pp 15±19 Jafri RA, Britton KE, Nimmon CC, Solanki K, Al-Nahas A, Bomanji J, Fettich J, Hawkins LA (1988) Technetium-99m MAG3, a comparison with iodine-123 and iodine-131 ortho-iodohippurate, in patients with renal disorders. J Nucl Med 29:147±158 Kletter K (1988) Neue Aspekte der nuklearmedizinischen Nierenfunktionsdiagnostik: Verbesserte Aussagekraft durch pharmakologische Intervention und quantitative Analyseverfahren [in German]. Wien Klin Wochenschr 100 (Suppl 177) Mallinckrodt (1992) TechneScan MAG3 product information. Malinckrodt, Phillipsburg, NJ Russel CD, Thorstad B, Yester MV, Stutzman M, Baker T, Dubovsky EV (1988) Comparison of technetium-99m MAG3 with iodine-131 hippuran by a simultaneous dual channel technique. J Nucl Med 29:1189±1193 Taylor A, Eshima D, Fritzberg AR, Christian PE, Kasina S (1986) Comparison of iodine-131 OIH and technetium-99m MAG3 renal imaging in volunteers. J Nucl Med 27:795±803 United States Pharmacopeial Convention (2005) Official Monographs: USP 28, technetium Tc-99m mertiatide injection. United States Pharmacopeia (USP) 28±national formulary (NF) 23, p 1858
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Van Duzee BF, Bugaj JE (1981) The effect of total technetium concentration on the performance of a skeletal imaging agent. Clin Nucl Med 6(Suppl):P148
12.9
99m
12.9.1
Tc-Labeled Hepatobiliary Agents
99m
Tc-IDA (Iminodiacetic Acid) Derivatives
I. Zolle and A. G. Bratouss Accepted Chemical Names N-(2,6-diethylphenylcarbamoylmethyl)-iminodiacetic acid (Etifenin, Ph. Eur.) N-(2,6-dimethylphenylcarbamoylmethyl)-iminodiacetic acid (Lidofenin, USP) N-(2,4,6-trimehtyl-3-bromophenylcarbamoylmethyl)-iminodiacetic acid (Mebrofenin) N-(2,6-diisopropylphenylcarbamoylmethyl)-iminiodiacetic acid (Disofenin) Kit Components *
Chemical Structures
Etifenin
20.0 mg
Mebrofenin
40.0 mg
Disofenin
20.0 mg
Tin(II)-chloride-dihydrate 0.2±0.6 mg
Etifenin
Listed Trade Names Etifenin ± EHIDA (Rotop) as disodium salt ± Hepatobida Mebrofenin ± TCK-22 (CIS Bio) CholeCIS Choletec (Bracco) Bridatec (Sorin) Disofenin ±
Mebrofenin
DISIDA Hepatolite Disofenin
* The composition of the kit components may vary with new manufacturers
Preparation The kit contains the lyophilized, sterile ingredients in a multidose vial. Labeling with 99m Tc eluate is carried out under aseptic conditions by adding 1±5 ml of sterile 99mTc-sodium pertechnetate to the vial (0.3±1.5 GBq resp., 8.1±40.5 mCi). The reaction is allowed to proceed at room temperature for 15 min. 99mTc-iminodiacetic acid (IDA) preparations
315
316
12.9
99m
Tc-Labeled Hepatobiliary Agents
are sterile, pyrogen-free, clear, colorless solutions suitable for intravenous injection. The resulting pH should be 4.0±6.0 (TCK-22), 4.2±5.7 (Choletec), and 6.5±7.5 (Bridatec). Description of the Kit. Etifenin is officinal in the European Pharmacopeia (Ph. Eur.) Diethyl-IDA or EHIDA is a registered radiopharmaceutical (kit) in Europe. Three IDA derivatives (lidofenin, disofenin, and mebrofenin) have been included in the USP since the first hepatobiliary agent dimethyl-IDA, with the generic name lidofenin, was introduced (Loberg et al. 1976). 99m Tc-IDA complexes are formed easily with reduced technetium at room temperature. The size of the substituents attached to the phenyl ring does affect the labeling yield, radiochemical purity, and stability (Loberg et al. 1976; Ryan et al. 1977). Labeling is also affected by pH and the ligand concentration, showing higher labeling at low pH (Nunn and Schramm 1981). The amount of tin has no affect on the labeling yield; however, high labeling is depending on maintaining tin in the reduced state. Isotopic dilution is observed with higher concentrations of 99Tc in the first eluate of new generators, reducing the labeling efficiency (Ponto et al. 1987). Increasing the reaction time to 30 min will ensure maximum labeling.
Clinical Applications Intravenous injection: Hepatobiliary scintigraphy · To evaluate hepatocyte function · To demonstrate patency or obstruction of cystic duct · To rule out acute cholecystitis · To demonstrate common bile duct obstruction · As a control after surgical intervention · To verify hepatic bile duct atresia in infants Time of Examination. Hepatobiliary scintigraphy is started 5 min after the intravenous injection. Thereafter, scintigrams are taken at 10-min intervals up to 60 min. If the gallbladder is not visualized within 60 min, delayed images up to 4 h after administration of the radiotracer are obtained. Recommended Activities for Indications Hepatobiliary scintigraphy: 75±185 MBq, injected intravenously 150 MBq maximum recommended activity 1±2.6 MBq/kg body weight (normal bilirubin level) < 0.5 mg etifenin/kg body weight Pediatric Dose. The amount of radioactivity for infants and children administered for hepatobiliary scintigraphy is based on body weight, using the scaling factors given in Appendix 1, Table A1.2. The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Additional Information The patient should not eat 2±6 h prior to the hepatobiliary scintigraphy, because hepatocyte clearance of the radiotracer and parenchymal transit time is affected by the ingestion of food. The gallbladder cannot be visualized in 65% of cases within the first 60 min of injection of the 99mTc-IDA complex, even if the cystic duct is patent (FinkBennett 1995). Gallbladder contractility can be provoked with a fatty meal or intravenous cholecystokinin. Persistent nonvisualization of the gallbladder during a 4-h period is suggestive of acute cholecystitis; whereas delayed visualization of the gallbladder after 1.5 h up to 4 h is more typical of chronic cholecystitis (Weissmann et al. 1979). To enhance gallbladder visualization, cholecystokinin or sincalide have been used to induce contraction and subsequent filling of the gallbladder. The usual intravenous dose of sincalide is 0.02 lg/ kg, administered either 30 min before imaging is started or after the nonvisualization of the gallbladder within 1 h. The limitations of this medication in cholescintigraphic studies have been described (Freeman et al. 1981). Narcotic (opioid) analgesics (morphine, meperidine) and phenobarbital cause a marked increase in biliary tract pressure. The increase of intraluminal common bile duct pressure by morphine (50±60%) has been used to differentiate between acute and chronic cholecystitis. Morphine-augmented cholescintigraphy has been considered superior to conventional hepatobiliary scintigraphy in assessing cystic duct patency because diagnostic results are obtained faster. The increase in common bile duct pressure is sufficient to overcome the resistance to bile flow caused by a sludge-filled gallbladder, so that the radiotracer may penetrate the cystic duct into the gallbladder. A dose of 0.04 mg/kg morphine sulfate diluted to 10 ml with saline is administered intravenously over 3 min, when the gallbladder has not been visualized within 60 min after the administration of the 99mTc-IDA complex. Serial images are then obtained at 5-min intervals for 30 min. In the case of persistent nonvisualization of the gallbladder after morphine administration, acute cholecystitis is diagnosed (Fink-Bennett 1995). If, however, the gallbladder is visualized 5±30 min after morphine administration, chronic cholecystitis is present. Morphine should not be given to patients with a history of drug abuse, an allergy to morphine, or with pancreatitis. Phenobarbital enhances the biliary conjugation and excretion of bilirubin. It promotes the excretion of organic anions such as 99mTc-IDA complexes that are not conjugated by the liver. The hepatic extraction of 99mTc-IDA complexes and canalicular bile flow are increased; thus, phenobarbital is used in neonates for hepatobiliary imaging primarily to increase the diagnostic accuracy of differentiating between neonatal hepatitis and biliary atresia. The administered dose to increase the rate of excretion of a 99m Tc-IDA complex is approximately 5 mg/kg per day for at least 5 days prior to the imaging procedure (Majd et al. 1981). Nicotinic acid in high doses may affect the cholescintigraphy because of poor extraction and elimination of the radiotracer (toxic effect on hepatocytes). Total parenteral nutrition may cause delayed or no visualization of the gallbladder, even in patients with no gallbladder disease caused by bile stasis and the formation of thick viscous jelly-like bile. Nonvisualization of the gallbladder may also be caused by hepatic artery infusion during chemotherapy.
317
318
12.9
99m
Tc-Labeled Hepatobiliary Agents
Quality Control Radiochemical Purity. The Ph. Eur. (Council of Europe 2005) requires thin-layer chromatography (TLC) on silica gel (SG) fiberglass sheets (migration distance of 10±15 cm) for the analysis of the 99mTc-EHIDA complex, using 0.9% sodium chloride solution (saline) as solvent. Reduced, hydrolized technetium remains at the start; the 99mTc-etifenin complex is identified at an Rf of 0.4±0.5; unbound 99mTc-Na-pertechnetate is measured at the solvent front. The radiochemical purity of the 99mTc-EHIDA complex should not be less than 95% (Ph. Eur.). Recommended Methods Thin-layer chromatography. TLC with two different solvent systems is based on the separate identification of labeled impurities (Nunn et al. 1983). · System I: In saline (20%) unbound 99mTc-Na-pertechnetate is identified at the solvent front (Rf = 1). The sum of activities of reduced, hydrolized technetium and the 99m Tc-IDA complex is measured at the start (Rf = 0). · System II: Using Gelman ITLC-SG and acetonitrile/water as solvent, reduced, hydrolized activity is identified separately at the start (Rf = 0). System I Stationary phase: Solvent: Developing time:
Gelman ITLC-SA, 1 ´ 9.5 cm Saturated NaCl solution 5 min
Rf values:
99m
Tc-IDA complex: Tc reduced, hydrolized: 99m Tc-Na-pertechnetate: 99m
0.0±01 0.0±0.1 0.9±1.0
System II Stationary phase: Solvent: Developing time:
Gelman ITLC-SG, 1 ´ 9.5 cm Acetonitrile±water (3 : 1) 5 min
Rf values:
99m
Tc reduced, hydrolized: Tc-IDA complex: 99m Tc-Na-pertechnetate: 99m
0.0±0.1 0.9±1.0 0.9±1.0
Quantification of labeled components. Each chromatogram is measured (TLC linear analyzer or gamma counter), and the regional radioactivities are expressed as a percentage of the total recovered counts. The percentage of free 99mTc Na-pertechnetate (F) and reduced, hydrolized activity (H) are determined and the pure 99mTc-IDA complex quantified according to the equation: 99m
Tc-IDA complex
% 100
%
F H
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Results of analysis (12 samples) Results were obtained using the analytical method described by Nunn et al. (1983). Labeling and stability
15 min (%)
3 h (%)
99m
96.5 Ô 1.68 1.6 Ô 1.51 1.9 Ô 0.61
95.2 Ô 0.71 2.9 Ô 1.02 1.9 Ô 0.59
Tc-IDA complex Tc-Na-pertechnetate 99m Tc-reduced, hydrolized 99m
Pharmacokinetic Data Hepatobiliary excretion of 99mTc-IDA complexes is governed by molecular size (optimal molecular weight: 700±900 Da) and structural configuration. Two molecules of ligand are coordinated to one technetium atom in the +3 oxidation state. 99mTc-IDA complexes have a negative charge, high polarity, and show high binding to plasma protein (Loberg and Fields 1978). Substituents attached to the phenyl ring affect the degree of hepatic uptake and the rate of excretion, as well as urinary elimination of the 99mTc-IDA complex (Nunn et al. 1983). Approximately 82% of the injected dose of 99mTc-EHIDA, 88% of 99mTc-disofenin, and 98% of 99mTc-mebrofenin are extracted by the hepatocytes and secreted into bile with a hepatic excretion half-time of 37.3, 19.0, and 17.0 min, respectively (Krishnamurthy and Krishnamurthy 1989; Krishnamurthy and Turner 1990). Clinical comparison of diethyl-IDA (etifenin) and diisopropyl-IDA (disofenin) was also reported (Klingensmith et al. 1981). 99mTc-DISIDA and 99mTc-mebrofenin show least hepatic retention and are best suited to delineate hepatic biliary anatomy (Krishnamurthy and Krishnamurthy 1989). 99m Tc-IDA complexes are excreted into bile as the original bis-coordinated complex; they are not reabsorbed by epithelia of the biliary ducts nor metabolized, and released into the duodenum unchanged (Krishnamurthy and Krishnamurthy 1989; Loberg et al. 1976). Excretion across the bile canalicular membrane is a carrier-mediated process (Nielson and Rasmussen 1975). Following intravenous injection, the 99mTc-IDA complex is bound to plasma protein (mainly albumin) and carried to the liver (Nicholson et al. 1980). Accumulation in the liver involves the same carrier-mediated, non±sodium-dependent organic anion transport processes as for the uptake of bilirubin. In the space of Disse, the albumin±99mTcIDA conjugate is dissociated to facilitate active transport of the 99mTc-IDA complex into hepatocytes (Krishnamurthy and Krishnamurthy 1989). In patients with normal hepatobiliary function, maximal liver uptake is measured at 12 min (99mTc-mebrofenin, 10.9 Ô 1.9 min; 99mTc-disofenin, 11.5 Ô 3.1 min) (Fritzberg 1986). The radioactivity is half this value within approximately 20 min. The gallbladder is well visualized 20 min postinjection. Intestinal activity appears on the average at 15±30 min. The common bile duct may be visualized after 14 min. The upper limit of ªnormalº for visualization of these structures is 1 h (Weissmann et al. 1979). The blood clearance curve shows two major half-times of elimination, a fast component with T1/2 = 2.5 min (23±40%) and a slower component with T1/2 = 17 min (7±16%); a small percentage is excreted with T1/2 ³ 16 h (1.4±2.6%). The total radioactivity in blood at 1 and 24 h after the intravenous injection is 3%, and less than 1% of the administered dose, respectively (Brown et al. 1982).
319
320
12.9
99m
Tc-Labeled Hepatobiliary Agents
Hepatic extraction efficiency decreases with increasing serum bilirubin levels. With impaired hepatocyte function, high plasma concentrations (> 8 mg/100 ml) may inhibit uptake of 99mTc-IDA complexes. As hepatobiliary excretion decreases, renal accumulation of certain 99mTc-IDA complexes is observed (Fink-Bennett 1995). Normally, the renal elimination of IDA complexes is low: cumulative urinary excretion of 99mTc-mebrofenin is 1.2% in 3 h, and 7.1% in the case of 99mTc-DISIDA. With a serum bilirubin level of 15 mg/100 ml, urinary excretion increases to approximately 5 and 23%, respectively (Fritzberg 1986). 99mTc-etifenin, on the other hand, shows a cumulative urinary excretion of 17% in 5 h, with normal bilirubin levels (Nielson and Rasmussen 1975). Among the many ligands that have been evaluated, 99mTc-mebrofenin has shown the best in vivo characteristics, namely high hepatocyte extraction (98%) and a fast clearance (T1/2 = 17 min), a rapid hepatobiliary-to-bowel transit time, and low urinary excretion. 99mTc-mebrofenin provides excellent visualization of the common bile duct and the gallbladder at serum bilirubin levels as high as 30 mg/100 ml (Fink-Bennett 1995; Krishnamurthy and Turner 1990). Healthy persons fasting overnight prior to the examination showed 56% of the radiotracer in the gallbladder; 44% were excreted directly into the small intestine (Brown et al. 1982). The fraction of gallbladder emptying following a whole meal has been measured as 87%. Nonvisualization of the gallbladder with visualization of the common bile duct and the duodenum in fasting patients within 2 h is diagnostic of acute cholecystitis (Weissmann et al. 1979). It has been suggested to repeat scintigraphy with the 99mTc-IDA complex 30 min after stimulation of gallbladder contractility with intravenous cholecystokinin. Persistent nonvisualization of the gallbladder confirms cystic duct obstruction, caused by acute cholecystitis. If the gallbladder visualizes after administration of cholecystokinin, chronic cholecystitis is diagnosed (Weissmann et al. 1979). Acute cholecystitis can be virtually excluded if the gallbladder, the common bile duct, and the duodenum are visualized in fasting patients within 1 h after injection of the 99mTc-IDA complex (Weissmann et al. 1979). An obstruction or occlusion of the common bile duct affects the clearance of the 99m Tc-IDA complex into the duodenum, resulting in an increased transit time and an abnormal scintigram. The absence of biliary tract visualization in the presence of normal hepatic extraction indicates an acute common bile duct obstruction from a stone in the common bile duct (Fink-Bennett 1995). Few reports on adverse reactions after intravenous injection of IDA-derivatives are available. The LD50 value of etifenin, determined in mice and in rats, is 280 and 270 mg/kg body weight, respectively. The LD50 value of mebrofenin is given with 285 mg/kg body weight (in mice) and 250 mg/kg body weight (in rats).
Radiation Dose The most exposed organs are the gallbladder wall, the upper large intestinal wall, the lower large intestinal wall, the small intestine, and the liver (Brown et al. 1982). The gallbladder receives the highest absorbed dose, 0.18±0.21 mGy/MBq. The relative amount of the delivered dose is strongly dependent on the type of stimulation used to induce gallbladder emptying. In fasting subjects (no gallbladder stimulation), an in-
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
crease in the radiation absorbed dose to the gallbladder by approximately 170% versus whole-meal gallbladder stimulation is observed (Brown et al. 1982). Severe hepatocellular disease (high bilirubin levels) will cause a shift in the excretion pattern, with the highest radiation absorbed dose delivered to the urinary bladder (Brown et al. 1982). The effective (whole body) dose equivalent is 0.024 mSv/MBq (International Commission on Radiological Protection 1987). The effective dose in adults (70 kg) resulting from 185 MBq (5 mCi) of intravenously injected 99mTc-IDA complex is 4.4 mSv.
Storage and Stability Storage. The lyophilized kit is stored at 2±8 8C. Stability. The
99m
Tc-IDA complex is stable for 6 h after preparation.
References Brown PH, Krishnamurthy GT, Bobba VR, Kingston E, Turner FE (1982) Radiation-dose calculation for five Tc-99m IDA hepatobiliary agents. J Nucl Med 23:1025±1030 Council of Europe (2005) Technetium 99mTc etifenin injection. European pharmacopeia 5.0, monograph no 585. Council of Europe, Maisonneuve, Sainte-Ruffine, p 1212 Fink-Bennett D (1995) Gallbladder and biliary ducts. Wagner HN Jr, Szabo Z, Buchanan JW (eds) In: Principles of nuclear medicine, 2nd edn. Saunders, Philadelphia, pp 946±957 Freeman LM, Sugarman LA, Weissmann HS (1981) Role of cholecystokinetic agents in 99mTc-IDA cholescintigraphy. Sem Nucl Med 11:186±193 Fritzberg AR (1986) Advances in the development of hepatobiliary radiopharmaceuticals. In: Fritzberg AR (ed) Radiopharmaceuticals: progress and clinical perspectives, vol. I. CRC Press, Boca Raton, pp 89±116 International Commission on Radiological Protection (1987) Technetium-labelled iminodiacetic acid (IDA) derivatives. In: Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol 18, no 1±4. Pergamon, Oxford, pp 201±205 Klingensmith WC, Fritzberg AR, Spitzer VM, Kuni CC, Shanahan WSM (1981) Clinical comparison of Tc-99m diisopropyl-IDA and diethyl-IDA for evaluation of the hepatobiliary system. Radiology 140:791±795 Krishnamurthy S, Krishnamurthy GT (1989) Technetium-99m-iminodiacetic acid organic anions: review of biokinetics and clinical application in hepatology. Hepatology 9:139±159 Krishnamurthy GT, Turner FE (1990) Pharmacokinetics and clinical application of technetium99m-labeled hepatobiliary agents. Sem Nucl Med 20:130±149 Loberg MD, Fields AT (1978) Chemical structures of Tc-99m-labeled N-(2,6-dimethylphenyl-carbamoylmethyl)iminodiacetic acid (Tc-HIDA). Int J Appl Radiat Isot 29:167±173 Loberg MD, Cooper MD, Harvey EB, Callery PS, Faith WC (1976) Development of new radio-pharmaceuticals based on N-substitution of iminodiacetic acid. J Nucl Med 17:633±638 Majd M, Reba R, Altman RP (1981) Effect of phenobarbital on Tc-99m-IDA scintigraphy in the evaluation of neonatal jaundice. Sem Nucl Med 11:194±204 Nicholson RW, Herman KJ, Shields RA, Testa HJ (1980) The plasma protein binding of HIDA. Eur J Nucl Med 5:311±312 Nielson P, Rasmussen F (1975) Relationship between molecular structure and excretion of drugs. Life Sci 17:1495 Nunn AD, Schramm E (1981) Analysis of Tc-HIDAs and factors affecting their labeling rate, purity, and stability. J Nucl Med 22:P52 Nunn AD, Loberg MD, Conley RA (1983) A structure-distribution-relationship approach leading to the development of Tc-99m-mebrofenin: an improved cholescintigraphic agent. J Nucl Med 24:423±430
321
322
12.10
99m
Tc-Labeled Peptides
Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radiopharmaceutical formulation problems. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 268±279 Ryan J, Cooper MD, Loberg MD (1977) Technetium-99m-labeled N-(2,6-dimethylphenylcarbamoylmethyl)iminodiacetic acid (Tc-99m-HIDA): a new radiopharmaceutical for hepatobiliary imaging studies. J Nucl Med 18:997±1004 United States Pharmacopeial Convention (2005) Official Monographs: USP 28, technetium Tc 99m disofenin injection, technetium Tc 99m lidofenin injection, technetium Tc 99m mebrofenin injection. United States Pharmacopeia (USP) 28±national formulary (NF) 23, pp 1854±1857 Weissmann HS, Frank MS, Bernstein LH, Freeman LM (1979) Rapid and accurate diagnosis of acute cholecystitis with Tc-99m-HIDA cholescintigraphy. Am J Roentg 132:523±528
12.10
99m
12.10.1
Tc-Labeled Peptides
99m
Tc-Depreotide
I. Zolle Chemical name
Chemical structure
Depreotide-trifluoroacetate
Depreotide = synthetic cyclic decapeptide:
99m
cyclo-(N-Me)Phe-Tyr-(D-Trp)-Lys-ValHcy(CH2CO-(b-Dap)-Lys-Cys-Lys±NH2)
Tc(V)O-depreotide
Technetium Tc 99m depreotide injection (USP)
Commercial products
Kit components Depreotide
Hcy = L-homocysteine b-Dap = L-1,2-diaminopropionic acid
47.0 lg resp. 50.0 lg
Tin(II)-chloride dihydrate
50.0 lg
Sodium D-glucoheptonate (gluceptate) dihydrate
5 mg
Edetate disodium dihydrate HCl and/or NaOH
NeoSpect
GE Healthcare
NeoTect
Berlex Laboratories
0.1 mg
Preparation The commercial kits contain the sterile, lyophilized components including preformed synthetic peptide in a nitrogen atmosphere, as a single dose. Labeling with 99mTc-pertechnetate injection is carried out under aseptic conditions by adding a volume of exactly 1 ml of eluate to the vial at ambient temperature. The 99mTc activity should not exceed 1.8 GBq (50 mCi). Before removing the syringe, an equal volume of headspace should be withdrawn to normalize the pressure in the vial. The shielded vial is agitated carefully for 10 s to dissolve the lyophilized material, and then the vial is placed into a lead-shielded boiling water bath for 10 min. After the labeling procedure, the vial is placed into the lead shield and cooled at room temperature for approximately 15 min.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
The vial must not be cooled under running water (product monographs, Amersham Healthcare 2000; Berlex Laboratories 2001). 99m Tc-depreotide is a clear, aqueous solution suitable for intravenous injection, used as a single dose. The pH of the injection solution is 6.0±8.0 (United States Pharmacopeial Convention 2005).
Description of the Kit Kits NeoSpect and NeoTect have almost identical composition, labeling of the cyclic decapeptide with 99mTc is performed by ligand exchange of intermediary 99mTc-glucoheptonate, using stannous ion for reduction and heating for 10 min in a boiling water bath. The injection solution should be inspected visually for particulate matter and discoloration before administration. Oxidative processes interfere with the labeling reaction. Only eluates from generators eluted regularly within 24 h after the previous elution may be used for labeling. The amount of 99mTc activity (up to 1.8 GBq resp., 50 mCi) used for labeling is based on calculations recommending activities of 555±740 MBq (15±20 mCi) for injection at a certain time after labeling, and on using a total volume of 1 ml of 99mTc-depreotide (47 resp., 50 lg) for one patient. Kits NeoSpect and NeoTect contain no antimicrobial agents. Saline used for dilutions must be prepared without addition of any bacteriostatic agent (product monographs, Amersham Healthcare 2000; Berlex Laboratories 2001). Depreotide (P829 Diatide Inc.) is a synthetic peptide comprising two separate domains. The pharmacophore is part of a cyclic hexapeptide, to which a linear tetrapeptide is appended via the thiol group of the homocysteine residue, Hcy(CH2CO). The linear sequence Ala-Lys-Cys-Lys-NH2 constitutes the structural requirements for complex formation with technetium. Cyclic configuration avoids reductive cleavage during labeling with Tc-99m, which has been observed with small peptides containing an accessible disulfide bridge (Vallabhajosula et al. 1996). 99m Tc-depreotide contains a triamide-thiol chelate (N3S), which coordinates oxotechnetium, having a Tc(V)O core.
Clinical Applications 99m
Tc-depreotide is valuable for scintigraphic imaging of solitary pulmonary nodules in combination with computer tomography (CT) or chest x-ray, in patients suspected of malignancy. Lung scintigraphy: Somatostatin receptor imaging of non±small cell lung cancer. Somatostatin is a neuroregulatory peptide secreted by the hypothalamus. Human somatostatin receptors (ssts) are expressed in the brain, anterior pituitary gland, pancreas, thyroid gland, and in the mucosa of the gastrointestinal tract (Hofland and Lamberts 1997; Patel 1999). Tumors arising from sst-positive cells in these organs contain a high density of ssts (Hofland et al. 2003; Lamberts et al. 1991; Reubi 1996).
323
324
12.10
99m
Tc-Labeled Peptides
The somatostatin analog depreotide consists of ten amino acids containing the key ssts-binding amino acid residues ± Tyr-(D-Trp)-Lys-Val ± protected in a cyclic configuration, increasing in vivo stability. Depreotide binds with high affinity to sst-positive tumors and their metastases (Vallabhajosula et al. 1996). The labeled analogue, 99mT-depreotide (P829), has been first used in patients (Virgolini et al. 1998) and evaluated for the detection of solitary pulmonary nodules in a multicenter trial (Blum et al. 1999, 2000). Experience gained with this ssts-binding radioligand in the diagnosis of non±small cell lung cancer has been reported (Menda and Kahn 2002). Comparative studies using 99mT-depreotide and 18F-FDG positron emission tomography (PET) in patients suspected of non±small cell lung cancer demonstrated high sensitivity of both functional imaging methods for detecting lung cancer in primary lesions and in hilar and mediastinal lymph nodes (Kahn et al. 2004). Another study investigated the involvement of regional lymph nodes in 56 patients with lung cancer and in 30 patients with benign lung lesions, using 99mT-depreotide singlephoton emission computer tomography (SPECT) and CT to enhance staging accuracy. Scintigraphic results displayed high sensitivity (93.7±99%), demonstrating that a negative result with 99mT-depreotide can exclude regional lymph node metastases with a high degree of probability (Danielsson et al. 2005). Response to endocrine therapy in advanced breast cancer patients could be predicted using sequential 99mTc-depreotide scintigraphy, thus selecting nonresponders as early as 3 weeks after initiation of treatment (Van den Bossche et al. 2006). Time of Examination. The optimal time for SPECT imaging is 2±4 h after the intravenous injection. Recommended Activities for Indications Lung scintigraphy: 555±740 MBq (15±20 mCi), injected intravenously £ 0.7 lg/kg body weight Pediatric Dose. The application of 99mTc-depreotide to patients less than 18 years is not recommended. No data are available for this age group.
Additional Information The diagnostic application of 99mTc-depreotide is restricted to a single intravenous injection. Contraindications are a known hypersensitivity against depreotide, or against another kit component. 99m Tc-depreotide should not be mixed with other drugs or components and should be injected separately. Attention should be given to patients with reduced kidney function because of decreased renal excretion causing an increased radiation exposure. Attention should also be given to patients with reduced liver function. Patients should drink sufficient water and should be encouraged to frequent bladder emptying during the first hours after injection. Since depreotide binds to somatostatin receptors, caution should be paid to patients with insulinoma or diabetes mellitus.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Quality Control Radiochemical Purity. 99mTc-depreotide is not described in the European Pharmacopeia. Thin-layer chromatography (TLC) is recommended by the manufacturer, using instant (I)TLC-silica gel (SG) strips as a stationary phase and analysis in two solvent systems. Using methanol/1 M ammonium acetate 1 : 1 (MAM) as mobile phase, the insoluble 99mTc components are measured at the start (Rf = 0±0.4). With saturated NaCl solution as mobile phase, free 99mTc-sodium pertechnetate, 99mTc-glucoheptonate, and 99m Tc-edetate move with the solvent front and are measured at Rf = 0.75±1.0. The radiochemical purity of 99mTc-depreotide should not be less than 90% (United States Pharmacopeial Convention 2005). The radiochemical purity should be analyzed prior to administration of 99mTc-depreotide. Methods Recommended by the Manufacturer Thin-layer chromatography Stationary phase: Gelman ITLC-SG strips (precut to 2.0 ´ 10 cm) Solvent I: MAM Solvent II: Saturated sodium chloride solution (SSCS) Procedure Aliquots are spotted and analyzed without drying. · System I: Gelman ITLC-SG fiberglass plates and MAM as solvent: Reduced, hydrolized 99mTc-technetium is measured at the start (A); 99mTc-depreotide and free 99m Tc-Na-pertechnetate as well as the 99mTc complexes (gluceptate and edetate) move with the solvent front. · System II: Gelman ITLC-SG fiberglass plates and saturated sodium chloride as solvent: 99mTc-depreotide and colloidal 99mTc activity remain at the start; 99mTc-Na-pertechnetate and the 99mTc-complexes (gluceptate and edetate) are measured at the solvent front (B). Table 1. Thin-layer chromatography on silica gel plates using two solvent systems 99m
System I (MAM)
Reduced, hydrolized
System II (SSCS)
99m Tc-depreotide and colloidal 99mTc activity at origin Free 99mTc-pertechnetate and the 99mTc-complexes (gluceptate and edetate) at the solvent front:
Tc activity at the start:
(A) < 3%
(B)
A and B represent labeled impurities: < 10% 99m
Tc-depreotide (%) = 100±%(A+B)
Preparation of saturated sodium chloride solution (SSCS) Five grams of sodium chloride are dissolved in 10 ml distilled water in the TLC tank. Over a period of 10±15 min, the tank is swayed repeatedly. Undissolved sodium chloride should settle at the bottom. If all sodium chloride dissolves, more sodium chloride should be added.
325
326
12.10
99m
Tc-Labeled Peptides
Preparation of MAM · 1 M ammonium acetate: 3.9 g ammonium acetate is dissolved in 50 ml distilled water, the solution is stable for one month. · Methanol/1 M ammonium acetate (1 : 1): one part methanol is mixed with one part of the 1 M ammonium acetate solution. This solution should be prepared every day. Method of analysis (TLC) 1. Fill the TLC tanks (beakers) each with 0.5 ml of MAM or SSCS. 2. Close the tanks (beakers) and allow them to equilibrate. 3. Apply 1 drop of 99mTc-depreotide (5±10 ll), using a 1-ml syringe with a 21-gauge needle onto each of the Gelman ITLC-SG strips, 1.0 cm from the bottom. Do not allow the spot to dry. 4. Develop each plate in the covered TLC tank, using MAM and SSCS, respectively, until the upper edge of the plates is reached. 5. Allow the plates to dry. 6. Cut the ITLC-SG MAM plate at Rf = 0.4 (A). 7. Cut the ITLC-SG SSCS plate at Rf = 0.75 (B). 8. Measure the radioactivity of each portion in a counter and record separately. 9. Calculate the percentage of A and B as a fraction of the sum of recovered counts. 10. Calculate the radiochemical purity of 99mTc-depreotide (Table 1).
Pharmacokinetic Data After intravenous injection of 99mTc-depreotide, the elimination from blood is described by three effective half-times, namely T1/2 £ 5 min, 45 min, and 22 h. Approximately 12% of injected 99mTc-depreotide is bound to plasma proteins (5-min plasma sample). Four hours after injection, 71±84% of activity in blood was bound to depreotide, in the urine less, namely, 61±64% (NeoTect product monograph, Berlex Laboratories 2001). High-affinity binding to somatostatin receptors was demonstrated in vivo using Lewis rats bearing CA20948 rat pancreatic tumor implants, and in vitro using human tumor cell membranes. Tumor uptake in rats was 4.9% injected dose (ID)/g at 90 min after injection, compared with 2.9% in the case of 111In-(diethylene triamine pentaacetate [DTPA])octreotide (Vallabhajosula et al. 1996). In patients, specific uptake in single pulmonary nodules is seen 1.5±2 h postinjection, also in regional lymph nodes overexpressing somatostatin receptors. Lymphoreticular response affects initially hilar, mediastinal, supraclavicular and axillary nodes, extending to distant nodes and the spleen (Danielsson et al. 2005). Increased uptake of 99mTc-depreotide is seen in the spine, sternum and rib ends, and somewhat lower in the hilar and mediastinal regions. Nonspecific mediastinal uptake of 99mTc-depreotide has been reported (Menda et al. 2001). 99m Tc-depreotide is not metabolized and is excreted unchanged (>90%). The major route of excretion is the renal system. Four hours after injection, 12% of injected radioactivity is measured in the urine (NeoTect product monograph, Berlex Laboratories 2001). The average renal clearance amounts to approximately 0.3 ml/min/kg. The average overall clearance is 2±4 ml/min/kg. External whole-body scintigraphy localized the highest activity in the abdomen (Kahn et al. 2004). Gastrointestinal excretion is £ 5%.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
A fraction of the injected activity is retained in the kidneys, indicating proximal tubular reabsorption, as has been observed with 111In-(DTPA)octreotide (Vallabhajosula et al. 1996).
Radiation Dose 99m
Tc-depreotide is excreted by the kidneys. The most exposed organs are the kidneys and urinary bladder, as well as the spleen, the liver, and the thyroid gland. The effective (whole body) dose equivalent for 99mTc-depreotide was calculated as 0.016 mSv/MBq (International Commission on Radiological Protection 1990). The effective dose in adults (70 kg) resulting from 740 MBq (20 mCi) of intravenously injected 99m Tc-depreotide is 11.84 mSv. The values are calculated assuming a 4.8-h bladder voiding period. The absorbed radiation dose to the lung resulting from an intravenous injection of 555 MBq (15 mCi) of 99mTc-depreotide for lung scintigraphy is 7.8 mGy.
Storage and Stability Storage. Kits should be stored at ±10 8C or below. Keep the solution at 15±25 8C. Stability.
99m
99m
Tc-depreotide injection
Tc-depreotide injection solution is stable for 5 h.
References Amersham Healthcare (2000) Product monograph for the NeoSpect kit for the preparation of Tc99m depreotide. Amersham Healthcare, UK Berlex Laboratories (2001) Product monograph for the NeoTect kit for the preparation of Tc-99m depreotide. Berlex Laboratories, Wayne, NJ (Diatide, NDA No. 21-012) Blum JE, Handmaker H, Rinne NA (1999) The utility of a somatostatin-type receptor binding peptide radiopharmaceutical (P829) in the evaluation of solitary pulmonary nodules. Chest 115:224±232 Blum JE, Handmaker H, Lister-James J, Rinne NA (2000) NeoTect solitary pulmonary nodule study group. A multicenter trial with a somatostatin analog 99mTc-depreotide in the evaluation of solitary pulmonary nodules. Chest 117:1232±1238 Danielsson R, Bââth M, Svensson L, Forslæv U, Kælbeck K-G (2005) Imaging of regional lymph node metastases with 99mTc-depreotide in patients with lung cancer. Eur J Nucl Med Mol Imag 32:925±931 Hofland LJ, Lamberts SWJ (1997) Somatostatin analogs and receptors: diagnostic and therapeutic applications. Cancer Treat Res 89:365±382 Hofland LJ, Lamberts SWJ, Van Hagen PM, Reubi JC, Schaeffer J, Waaijers M, Van Koetsveld PM, Srinivasan A, Krenning EP, Breeman WAP (2003) Crucial role for somatostatin receptor subtype 2 in determining the uptake of [111In-DTPA-D-Phe1]octreotide in somatostatin receptor±positive organs. J Nucl Med 44:1315±1321 International Commission on Radiological Protection (1990) ICRP Publication 60: recommendations of the International Commission on Radiological Protection. In: Annals of the ICRP, vol 21, no 1±3. Pergamon, Oxford
327
328
12.11
99m
Tc-Labeled Monoclonal Antibodies
Kahn D, Menda Y, Kernstine K, Bushnell DL, McLaughlin K, Miller S, Berbaum K (2004) The utility of 99mTc-depreotide compared with F-18 fluorodeoxyglucose positron emission tomography and surgical staging in patients with suspected non-small cell lung cancer. Chest 125:494±501 Lamberts SWJ, Krenning EP, Reubi JC (1991) The role of somatostatin and ist analogs in the diagnosis and treatment of tumors. Endocr Rev 12:450±482 Menda Y, Kahn D (2002) Somatostatin receptor imaging of non-small cell lung cancer with 99mTc depreotide. Semin Nucl Med 32:92±96 Menda Y, Kahn D, Bushnell DL, Thomas M, Miller S, McLaughlin K, Kernstine KH (2001) Nonspecific mediastinal uptake of 99mTc-depreotide (NeoTect). J Nucl Med 42(Suppl):304P Patel YC (1999) Somatostatin and its receptor family. Front Neuroendocrinology 20:157±198 Reubi JC, Schaer JC, Laissue JA, Waser B (1996) Somatostatin receptors and their subtypes in human tumors and in peritumoral vessels. Metabolism 45:39±41 United States Pharmacopeial Convention (2005) Official Monographs: USP 28, technetium Tc 99m depreotide injection. United States Pharmacopeia Convention, Rockville, Md, p 1853 Vallabhajosula S, Moyer BR, Lister-James J, McBride BJ, Lipszyc H, Lee H, Bastidas D, Dean RT (1996) Preclinical evaluation of technetium-99m-labeled somatostatin receptor-binding peptides. JNM 37:1016±1022 Van Den Bossche B, Van Belle S, De Winter F, Signore A, Van de Wiele C (2006) Early prediction of endocrine therapy effect in advanced breast cancer patients using 99mTc-depreotide scintigraphy. J Nucl Med 47:6±13 Virgolini I, Leimer M, Handmaker H, Lastoria S, Bischof C, Muto P, Pangerl T, Gludovacz D, PeckRadosavljevic M, Lister-James J, Hamilton G, Kaserer K, Valent P, Dean R (1998) Somastotatin receptor subtype specific and in vivo binding of a novel tumor tracer, 99mTc-P829. Cancer Res 58:1850±1859
12.11
99m
12.11.1
Tc-Labeled Monoclonal Antibodies
99m
Tc-Arcitumomab
F. Rakis Chemical name Arcitumomab IMMU-4 Fab' anti-CEA monoclonal antibody fragments Technetium Tc 99m arcitumomab injection (USP) 99m
Tc-arcitumomab injection
99m
Tc-CEA-Scan injection
Kit components
Commercial products
Arcitumomab
1.25 mg
Stannous chloride
0.29 mg
Potassium sodium tartrate tetrahydrate Sodium acetate trihydrate Sodium chloride Sucrose
CEA-Scan
Immunomedics Europe
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Preparation The carcinoembryonic antigen (CEA)-Scan kit contains the lyophilized, sterile components in argon atmosphere, ready for aseptic labeling with 99mTc-sodium pertechnetate. Labeling is carried out by adding 1.0 ml of 99mTc activity to the vial, not exceeding 1.11 GBq/ml (30 mCi/ml). The vial is allowed to react at room temperature for at least 5 min, and then 1 ml saline is added to the labeled product and mixed well. 99m Tc-CEA-Scan injection is a clear, colorless solution suitable for intravenous injection, used as a single dose (740±1100 MBq; resp., 20±30 mCi). The total volume is 2 ml. The pH of the injection solution is 5.0±7.0. The injection solution should be inspected visually for particulate matter and discoloration. If either is present, the product should be discarded (Immunomedics Europe 2000).
Description of the Kit Each 3-ml vial contains 1.25 mg arcitumomab (IMMU-4 Fab' anti-CEA monoclonal antibody fragments, consisting mainly of Fab', but also containing F(ab')2 at £ 5% of total protein, with heavy- and light-chain fragments), buffered at pH 5.0±7.0. Before labeling, the 99mTc activity should be adjusted to a final concentration of 1.11 GBq/ml (30 mCi/ml), using a 2-ml vial. Isotopic dilution is observed with higher concentrations of 99Tc in the first eluate; therefore, only eluates from generators eluted regularly within 24 h after the previous elution may be used for labeling (Ponto et al. 1987). The CEA-Scan kit contains no antimicrobial agents (Immunomedics Europe 2000).
Clinical applications 99m
Tc-CEA-Scan injection solution is indicated for the detection of malignant lesions in patients with a history of colorectal carcinoma and with evidence of recurrence and/or metastases. 99mTc-CEA-Scan is employed as an adjunct to standard noninvasive imaging techniques, such as ultrasonography or computer tomography (CT), in the following situations: · Patients with evidence of recurrence and/or metastatic carcinoma of the colon or rectum, who are undergoing an evaluation for the extent of disease, such as prior to surgical resection and/or other therapy · Patients with suspected recurrence and/or metastatic carcinoma of the colon or rectum in association with rising levels of CEA The specificity of monoclonal antibodies for the detection of heterogenous carcinoembryonic antigen posed a considerable uncertainty (Primus 1983). The metabolism and kinetics of labeled antibodies affected the detection of liver metastases of colorectal cancer (Behr et al. 1995). The utility of external immunoscintigraphy with the IMMU-4 technetium-99m Fab' antibody fragment was evaluated in patients undergoing surgery for carcinoma of the colon and rectum in a phase III clinical trial (Moffat et al. 1996). Both radioimmunoscintigraphy and computed tomography were used for predicting
329
330
12.11
99m
Tc-Labeled Monoclonal Antibodies
the resectability of recurrent colorectal cancer (Hughes et al. 1997). The safety and efficacy of repeated administrations of arcitumomab was demonstrated in patients with colorectal cancer (Wegener et al. 2000). Of considerable importance is the diagnosis of recurrence of colorectal carcinoma (Willkomm et al. 2000) and the detection of resectable rectal cancer recurrence by CEA immunoscintigraphy (Lechner et al. 2000). Time of Examination. A whole-body planar scan at 2±5 h postinjection can be used to localize sites of colorectal cancer. Immunoscintigraphy, using planar and single-photon emission computer tomography (SPECT) techniques, should be performed preferably 1±5 h after injection. Recommended Activities for Indications Planar and SPECT imaging: 750±1100 MBq (20±30 mCi), injected intravenously (30 s) 1 mg of Fab' fragment Since the recommended adult dose of Fab fragment injected as a single dose is limited with 1 mg, 1.6 ml of the injection solution may be used for one patient. Pediatric Dose. Recommendations by the Pediatric Task Group of the European Association of Nuclear Medicine (EANM) based on body weight should be followed (see Appendix 1, Table A1.2).
Additional Information Patients should be encouraged to drink sufficient water and to empty the bladder before scintigraphy is started. Frequent bladder emptying is recommended to reduce the radiation exposure to the bladder wall. Patients with known allergies or hypersensitivity to mouse proteins, human antimouse antibodies (HAMA) titers should be determined before administration of 99mTcCEA-Scan. Doses of arcitumomab up to 10 mg have not shown any serious adverse reaction. 99m Tc-CEAScan should be used only once in each patient (Immunomedics Europe 2000). Any remaining portion of the injection solution should be discarded.
Quality Control Radiochemical Purity 99m Tc-CEA-Scan is not described in the Eur. Pharmacopoeia. Thin-layer chromatography is recommended by the manufacturer using instant (I)TLC-silica gel (SG) fiberglass sheets for the identification of free 99mTc-Na-pertechnetate, using acetone as solvent. Unbound 99mTc-pertechnetate moves with the solvent front (Rf = 1.0). The insoluble 99mTc components are measured at the start. The radiochemical purity of 99mTc-arcitumomab should not be less than 90% (USP).
Chapter 12 Monographs of
99m
The analysis should be performed prior to administration of patient.
Tc Pharmaceuticals
99m
Tc-CEA-Scan in the
Thin-layer chromatography Stationary phase: Solvent: Developing time:
Gelman ITLC-SG fiberglass, 1 ´ 9.5 cm Acetone 5 min
Rf values:
99m
Tc-arcitumomab Tc reduced, hydrolized: 99m Tc-pertechnetate: 99m
0.0±0.1 0.0±0.1 0.9±1.0 (< 10%)
Procedure · A 10 ll sample of the labeled antibody is diluted with 1.5 ml saline, and immediately spotted for thin-layer chromatography. · When the solvent front is within 1 cm of the top, the strip is removed, dried, and analyzed in a radiochromatogram scanner. · Otherwise, the strip is cut into half and placed into two test tubes for measurement with a gamma scintillation counter or a dose calibrator. Calculate the percent impurity as follows: 99m
Tc-pertechnetate
%
Activity in upper piece 100 Activity in both pieces
Results of analysis (12 samples) Results were obtained by thin-layer chromatography in acetone, at different times after labeling. Labeling and stability
15 min (%)
3 h (%)
99m
95.3 Ô 0.32 4.7 Ô 0.48
92.7 Ô 0.44 7.3 Ô 0.21
Tc-Arcitumomab Tc-Na-pertechnetate
99m
Pharmacokinetic Data Pharmacokinetic studies were performed after the intravenous administration of 99m Tc-CEA-Scan. The elimination from the blood is indicated by 63% of baseline activity at 1 h after infusion, 23% after 5 h, and 7% after 24 h. The distribution half-time is approximately 1 h; the elimination from blood follows a half-time of approximately 13 h. Twenty-eight percent of the administered activity is excreted in the urine during the first 24 h after infusion (Immunomedics Europe 2000). CEA is expressed in a variety of carcinomas, particularly of the gastrointestinal tract (e.g., Crohn's disease, inflammatory bowel disease, post±radiation therapy to the bowel) and can be detected in the serum. IMMU-4 is specific for the classical 200 000-Da CEA that is found predominantly on the cell membrane. 99mTc-CEA-Scan complexes the circulating CEA and binds to CEA on the cell surface. Imaging efficacy and safety have been evaluated in four clinical trials to evaluate the presence, location, and extent of colorectal cancer, primarily in the liver and extrahepatic abdominal and pelvic regions.
331
332
12.11
99m
Tc-Labeled Monoclonal Antibodies
Radiation Dose 99m
Tc-CEA-Scan is excreted by the kidneys. The most exposed organs are the kidneys and urinary bladder, along with the spleen and liver. The effective (whole body) dose equivalent for 99mTc-CEA-Scan was calculated as 0.0131 mSv/MBq (International Commission on Radiological Protection 1990). The effective dose in adults (70 kg) resulting from 750 MBq (20.3 mCi) of intravenously injected 99mTc-CEA-Scan is approximately 9.8 mSv. The values were calculated assuming a 2-h bladder voiding period. The absorbed radiation dose to the kidneys resulting from an intravenous injection of 750 MBq (20.3 mCi) of 99mTc-CEA-Scan for colon scintigraphy is calculated as 75 mGy, the absorbed radiation dose to the spleen as 11.9 mGy (based on data obtained by the standard medical internal radiation dose [MIRD] method) (Immunomedics Europe 2000).
Storage and Stability Storage. Lyophilized kits should be stored at 2±8 8C, and not frozen. The 99mTc-CEAScan injection solution should be kept at 15±25 8C, and not refrigerated or frozen. Stability.
99m
Tc-CEA-Scan injection solution is stable for 4 h.
References Behr T, Becker W, Hanappel E, Goldenberg DM, Wolf F (1995) Targeting of liver metastases of colorectal cancer with IgG, F(ab')2, and Fab' anti-carcinoembryonic antigen antibodies labelled with 99m Tc: the role of metabolism and kinetics. Cancer Res. 55: 5777s±5785s Hughes KS, Pinsky CM, Petrelli NJ, Moffat FL Jr, Patt YZ, Hammershaimb L, Goldenberg DM (1997) Use of carcinoembryonic antigen radioimmunodetection and computed tomography for predicting the resectability of recurrent colorectal cancer. Ann Surg 226:621±631 Immunomedics Europe (2000) Product monograph for the CEA-Scan (Arcitumomab) kit for the preparation of Tc-99m CEA-Scan. Immunomedics Europe, Darmstadt, Germany International Commission on Radiological Protection (1990) ICRP Publication 60: recommendations of the International Commission on Radiological Protection. In: Annals of the ICRP, vol 21, no 1±3. Pergamon, Oxford Lechner P, Lind P, Goldenberg DM (2000) Can postoperative surveillance with serial CEA immunoscintigraphy detect resectable rectal cancer recurrence and potentially improve tumor-free survival? J Am Coll Surg 191:511±518 Moffat FL Jr, Pinsky CM, Hammershaimb L, Petrelli NJ, Patt YZ, Whaley FS, Goldenberg DM (1996) Immunomedics study group clinical utility of external immunoscintigraphy with the IMMU-4 technetium-99m Fab' antibody fragment in patients undergoing surgery for carcinoma of the colon and rectum: results of a pivotal, phase III trial. J Clin Oncol 14:2295±2305 Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radiopharmaceutical formulation problems. In: Hladik WB III, Saha GB, Study KT (eds) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 268±289 Primus FJ, Newell KD, Blue A, Goldenberg DM (1983) Immunological heterogeneity of carcinoembryonic antigen: antigenic determinants on carcinoembryonic antigen distinguished by monoclonal antibodies. Cancer Res 43:686±692 United States Pharmacopeial Convention (2005) Official Monographs: USP 28, technetium Tc-99m arcitumomab injection, United States Pharmacopeia (USP) 28±national formulary (NF) 23, p 1852
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Wegener W, Petrelli NJ, Serafini A, Goldenberg DM (2000) Safety and efficacy of arcitumomab imaging in colorectal cancer after repeated administration. J Nucl Med 41:1016±1020 Willkomm P, Bender H, Bangard M, Decker P, Grunwald F, Biersack HJ (2000) FDG PET and immunoscintigraphy with 99mTc-labeled antibody fragments for detection of the recurrence of colorectal carcinoma. J Nucl Med 41:1657±1663
12.11.2
99m
Tc-Sulesomab
F. Rakis Chemical name Sulesomab, IMMU-MN3 Fab'-SH antigranulocyte monoclonal antibody fragments 99m
Tc-Sulesomab injection
Kit components
Commercial products
Sulesomab
0.31 mg
Stannous chloride, dihydrate
0.22 mg
LeukoScan
Immunomedics Europe
Sodium chloride Hydrochloric acid Sodium potassium tartrate, tetrahydrate Sodium acetate, trihydrate Sucrose
Preparation The kit contains the lyophilized, sterile, pyrogen-free, inactive components in an argon or nitrogen atmosphere, ready for labeling with 99mTc-sodium pertechnetate. Labeling is carried out by first adding 0.5 ml of isotonic saline and swirling the content for 30 s; immediately after dissolution, 1 ml 99mTc-pertechnetate is added to the shielded vial, corresponding to an activity of at least 1,100 MBq (30 mCi). 99m Tc-LeukoScan is a clear, colorless solution suitable for intravenous injection, used as a single dose. The total volume is 1.5 ml. The pH of the injection solution is 5.0±7.0. The injection solution should be inspected visually for particulate matter and discoloration. If either is present, the product should be discarded (Immunomedics Europe 1997).
Description of the Kit Each 3-ml vial contains a lyophilized powder of sulesomab (IMMU-MN3 Fab'-SH anti± granulocyte monoclonal antibody fragment, consisting mainly of Fab', but also containing F(ab')2 at 5% of total protein, with heavy- and light-chain fragments) buffered to pH 5.0±7.0. The powder is dissolved by agitation during 30 s; the labeling reaction is completed after 10 min at room temperature.
333
334
12.11
99m
Tc-Labeled Monoclonal Antibodies
Isotopic dilution is observed with higher concentrations of 99Tc in the first eluate; therefore, only eluates from generators eluted regularly within 24 h after the previous elution may be used for labeling (Ponto et al. 1987). The LeukoScan kit contains no antimicrobial agents (Immunomedics Europe 1997).
Clinical Applications 99m
Tc-LeukoScan has been evaluated as a marker of infection/inflammation in patients with suspected osteomyelitis, joint infection involving implants, inflammatory bowel disease, and diabetic patients with foot ulcers. These heterogeneous patients have been diagnosed with high sensitivity (> 93%), comparable to bone scans with diphosphonates, but with considerably higher specificity (> 91%), offering a reliable imaging method based on the specificity of sulesomab, a murine anti±granulocyte monoclonal antibody Fab' fragment. In clinical trials with more than 350 patients, no induction of human anti-mouse antibody (HAMA) to antibody fragments has been observed. When a bone scan is positive and imaging with 99mTc-LeukoScan is negative, infection is unlikely. Single-photon emission computed tomography (SPECT) imaging may aid in differentiating osteomyelitis from soft tissue infections (Becker et al. 1994). The advantages of rapid imaging in different conditions of infection have been investigated (Barron et al. 1999; Becker et al. 1996; Gratz et al. 2000, 2003; Hakki et al. 1997; Harwood et al. 1999; Kampen et al. 1999). Time of Examination. Planar scintigraphy should be performed anytime between 1 and 8 h after injection of 99mTc-LeukoScan. Recommended Activities for Indications Planar and SPECT imaging: 750±1,100 MBq (20±30 mCi), injected intravenously 0.25 mg of Fab' antigranulocyte fragment Since the recommended adult dose of Fab' antigranulocyte fragment injected as a single dose is limited with 0.25 mg, 1.2 ml of the injection solution may be used for one patient. Pediatric Dose. The amount of radioactivity for infants and children is based on either body weight (static imaging) or body surface area (dynamic examinations). Recommendations by the Pediatric Task Group of the European Association of Nuclear Medicine (EANM) based on body weight should be followed (see Appendix 1, Table A1.2).
Additional Information Patients should drink sufficient water and be encouraged to empty the bladder before scintigraphy is started to reduce the radiation exposure to the bladder wall. HAMA titers should be determined before repeated administration of 99mTc-LeukoScan. Any remaining portion of the injection solution should be discarded.
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Quality Control Radiochemical Purity Thin-layer chromatography The manufacturer recommends TLC on instant (I)TLC-silica gel (SG) fiberglass sheets for the identification of free 99mTc-Na-pertechnetate, using acetone as solvent. Unbound 99m Tc-pertechnetate moves with the solvent front (Rf = 1.0). The radiochemical purity of 99mTc-LeukoScan should not be less than 90% (Immunomedics Europe 1997). The radiochemical purity should be analyzed prior to administration of 99mTc-LeukoScan. Thin-layer chromatography Stationary phase: Solvent: Developing time:
Gelman ITLC-SG (fiberglass), 1 ´ 9.5 cm Acetone 5 min
Rf values:
99m
Tc-sulesomab Tc reduced, hydrolized: 99m Tc-pertechnetate: 99m
0.0±0.1 0.0±0.1 0.9±1.0 (< 10%)
Procedure · A 10-ll sample of the labeled antibody is spotted undiluted and immediataly developed in acetone by thin-layer chromatography. · When the solvent front is within 1 cm of the top, the strip is removed, dried, and analyzed in a radiochromatogram scanner. · Otherwise, the strip is cut into half and placed into two test tubes for measurement with a gamma scintillation counter or a dose calibrator. 99m
Tc-pertechnetate
%
Activity in upper piece 100 Activity in both pieces
Results of analysis (12 samples) Results were obtained by thin-layer chromatography in acetone, at different times after labelling. Labeling and stability
15 min (%)
3 h (%)
99m
96.8 Ô 0.30 3.12Ô 0.15
94.7 Ô 0.38 5.3 Ô 0.34
Tc-Sulesomab complex Tc-Na-pertechnetate
99m
Pharmacokinetic Data Pharmacokinetic studies were performed after the intravenous administration of 99m Tc-LeukoScan. The elimination from the blood is indicated by 34% of baseline activity at 1 h after infusion, 17% at 4 h, and 7% after 24 h. The distribution half-time was approximately 1.5 h; the route of excretion is essentially renal, with 41% of the radiolabel excreted in urine over the first 24 h after injection (Immunomedics Europe 1997).
335
336
12.11
99m
Tc-Labeled Monoclonal Antibodies
Radiation Dose 99m
Tc-sulesomab is excreted by the kidneys. The most exposed organs are the kidneys and urinary bladder, and the spleen and liver. The effective (whole body) dose equivalent for 99mTc-sulesomab was calculated as 0.0103 mSv/MBq (International Commission on Radiological Protection 1990). The effective dose in adults (70 kg) resulting from 750 MBq (20.3 mCi) of intravenously injected 99mTc-LeukoScan is 7.7 mSv. The values were calculated assuming a 2-h bladder voiding period. The absorbed radiation dose to the kidneys resulting from an intravenous injection of 750 MBq (20 mCi) of 99mTc-LeukoScan for diagnostic immunoscintigraphy is calculated as 33.7 mGy, the absorbed radiation dose to the spleen as 11.8 mGy (based on data obtained by the standard medical internal radiation dose [MIRD] method) (Immunomedics Europe 1997).
Storage and Stability Storage. Lyophilized kits should be stored at 2±8 8C and not frozen. injection solution is kept at 15±25 8C and not refrigerated or frozen. Stability.
99m
99m
Tc-LeukoScint
Tc-LeukoScan injection solution is stable for 4 h.
References Barron B, Hanna C, Passalaqua A, Lamki L, Wegener WA, Goldenberg DM (1999) Rapid diagnostic imaging of acute nonclassic appendicitis by leukoscintigraphy with sulesomab, a technetium 99m-labeled anti-granulocyte monoclonal antibody Fab'. Surgery 125(3):288±296 Becker W, Bair J, Behr TM, Repp R, Streckenbach H, Beck H, Gramatzki M, Winship MJ, Goldenberg DM, Wolf F (1994) Detection of soft-tissue and osteomyeltis using a technetium-99m labeled anti-granulocyte monoclonal antibody fragment. J Nucl Med 35:1436±1443 Becker W, Palestro PJ, Winship MJ, Feld T, Pinsky CM, Wolf F, Goldenberg DM (1996) Rapid imaging of infections with a monoclonal antibody fragment (LeukoScan). Clinical Orthopaedics 329:263±272 Gratz S, Raddatz D, Hagenah G, Behr TM, Behe M, Becker W (2000) 99mTc-labelled antigranulocyte monoclonal antibody FAB' fragments versus echocardiography in the diagnosis of subacute infective endocarditis. Int J Cardiol 75:75±84 Gratz S, Schipper ML, Dorner J, Hoffken H, Becker W, Kaiser JW, Behe M, Behr TM (2003) LeukoScan for imaging infection in different clinical settings: A retrospective evaluation and extended review of the literature. Clin Nucl Med 28(4):267±276 Hakki S, Harwood SJ, Morrissey M, Camblin JG, Laven DL, Webster WB Jr (1997) Comparative study of monoclonal antibody scan in diagnostic orthopaedic infection. Clin Orthop Relat Res 335:275±285. Harwood SJ, Valdivia S, Hung GL, Quenzer RW (1999) Use of sulesomab, a radiolabeled antibody fragment, to detect osteomyelitis in diabetic patients with foot ulcers by leukoscintigraphy. Clin. Infect. Dis. 28(6):1200±1205 Immunomedics Europe (1997) Product monograph for LeukoScan (sulesomab). Issued by Immunomedics Europe, Darmstadt, Germany. International Commission on Radiological Protection (1990) ICRP publication 60: recommendations of the International Commission on Radiological Protection. In: Annals of the ICRP, vol 21, no 1±3. Pergamon, Oxford
Chapter 12 Monographs of
99m
Tc Pharmaceuticals
Kampen W, Brenner W, Terheyden H, Bohuslavizki KH, Henze E (1999) Decisive diagnosis of infected mandibular osteoradionecrosis with a Tc-99m-labeled anti-granulocyte FabÂ-fragment. Nuklearmedizin 38:309±311 Ponto JA, Swanson DP, Freitas JE (1987) Clinical manifestations of radiopharmaceutical formulation problems. Hladik WB III, Saha GB, Study KT (eds) In: Essentials of nuclear medicine science. Williams & Wilkins, Baltimore, pp 268±289
337
Appendix 1
Table A.1. Administration of Radioactive Substances Advisory Committee (ARSAC): radiation doses for children Calculation of administered activity to children based on body weight Body weight (kg)
Fraction of adult administered radioactivity scaling factors (F)
3 4 6 8 10 12 14 16 18 20 25 30 35 40 45 50 55 60 65
(0.1) a (0.1) a (0.1) a 0.11 0.14 0.17 0.20 0.23 0.26 0.28 0.36 0.43 0.50 0.57 0.64 0.64 0.79 0.86 1.00
ARSAC ± Administration of Radioactive Substances Advisory Committee; Notes for Guidance on the Administration of Radioactive Substances to Persons for Purposes of Diagnosis, Treatment or Research, January 1993 a Depending on local techniques and facilities the acceptable minimum administered activity will vary, regardless of the size of the child. The minimum value of the scaling factor is 0.1, since activities below 10% of the value of the adult radioactivity have resulted in poor image quality
340
Appendix 1 Table A.2. European Association of Nuclear Medicine (EANM): radiation doses for children (issued by the Pediatric Task Group of the EANM) Calculation of administered activity to children based on body weight Body weight (kg)
Fraction of adult administered radioactivity scaling factors (F)
3 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52±54 56±58 60±62 64±66 68 > 70
0.1 0.14 0.19 0.23 0.27 0.32 0.36 0.40 0.44 0.46 0.50 0.53 0.56 0.58 0.62 0.65 0.68 0.71 0.73 0.76 0.78 0.80 0.83 0.85 0.88 0.90 0.92 0.96 0.98 0.99 1.00
Example: To calculate the amount of radioactivity to be administered to a child with a body weight of 22 kg, the corresponding F = 0.5. Accordingly, the amount of radioactivity recommended for adults is multiplied by 0.5
Recommended Reading Textbooks in Radiopharmacy/Radiopharmacology Bçll U, Schicha H, Biersack H-J, Knapp WH, Reiners Chr, Schober O (eds) (1996) Nuklearmedizin, 2nd edn. Georg Thieme, Stuttgart Colombetti LG (ed) (1976±1986) CRC Series in radiotracers in biology and medicine. CRC Press, Boca Raton: Colombetti LG (ed) (1979) Principles of radiopharmacology, vol. I±II Colombetti LG (ed) (1982) Biological transport of radiotracers, vol. III Anghileri LJ (ed) (1982) General processes of radiotracer localization, vol. I±II Eckelman WC (ed) (1982) Receptor-binding radiotracers, vol. I±II Robertson JS (ed) (1983) Compartmental distribution of radiotracers
Appendix 1
Fritzberg AR (ed) (1986) Radiopharmaceuticals: progress and clinical perspectives, vol. I±II Cox PH (ed) (1982) Progress in radiopharmacology 3: selected topics. Martinus Nijhoff, The Hague Cox PH (ed) (1985) Radiopharmacy and radiopharmacology yearbook. Gordon and Breach, New York Cox PH, Mather SJ, Sampson CB, Lazarus CR (eds) (1986) Progress in radiopharmacy. Martinus Nijhoff, Dordrecht, The Netherlands Hladik WB III, Saha G, Study KT (eds) (1987) Essentials of nuclear medicine science. Williams & Wilkins, Baltimore Owunwanne A, Patel M, Sadek S (eds) (1995) Handbook of radiopharmaceuticals. Chapman & Hall, London Saha GB (1998) Fundamentals of nuclear pharmacy, 4th edn. Springer, Berlin Heidelberg New York Sampson CB (ed) (1994) Textbook of radiopharmacy: theory and practice, 2nd edn. Gordon and Breach Science, UK Wagner HN Jr, Szabo Z, Buchanan JW (eds) (1995) Principles of nuclear medicine, 2nd edn. Saunders, Philadelphia Good Radiopharmacy Practice Kristensen K, Norbygaard E (eds) (1984, 1987) Safety and efficacy of radiopharmaceuticals. Martinus Nijhoff, Boston (1984), Dordrecht (1987) Nordic Council on Medicines (1989) Radiopharmacy: preparation and control of radiopharmaceuticals in hospitals. Nordic Guidelines. NLN publication no. 26. Nordic Council on Medicines, Uppsala Quality Control of Radiopharmaceuticals Brandau W, Hotze L-A, Meyer G-J (1996) Qualitåtskontrolle In: Nuklearmedizin, Bçll U, Schicha H, Biersack H-J, Knapp WH, Reiners Chr, Schober O (eds) 4. Radiochemie, 2nd edn. [in German]. Georg Thieme, Stuttgart, pp 97±104 Frier M, Hesslewood SR (1980) Quality assurance of radiopharmaceuticals: a guide to hospital practice. Nucl Med Comm Special Issue 1980, Chapman and Hall, London Hammermaier A, Reich E, Bægl W (1986) Qualitåtskontrolle von in-vivo Radiopharmaka: Ein Handbuch fçr das nuklearmedizinische Labor zur Analytik radiochemischer Verunreinigungen [in German]. Reimers, ISH Heft 94, Bundesgesundheitsamt, Berlin Mallol J, Bonino C (1997) Comparison of radiochemical purity control methods for technetium radiopharmaceuticals used in hospital radiopharmacy. Nucl Med Commun 18:419±422 Millar AM (1989) Quality assurance of radiopharmaceuticals In: Theobald AE (ed) Radiopharmaceuticals: using radioactive compounds in pharmaceutics and medicine. Horwood, Chichester, pp 83±102 Johannsen B, Narasimhan DVS (eds) (1992) Preparation of kits for 99mTc-radiopharmaceuticals. International Atomic Energy Agency: IAEA-TECDOC-649. Vienna Robbins PJ (1985) Chromatography of Tc-99m-radiopharmaceuticals ± a practical guide, 2nd printing. Society Nuclear Medicine, New York Theobald AE (1990) Quality control of radiopharmaceuticals In: Sampson CB (ed) Textbook of radiopharmacy: theory and practice. Gordon and Breach, New York, pp 115±148
341
342
Appendix 1
Webber D, Zimmer AM, Spies SM (1983) Common errors associated with miniaturized chromatography. J Nucl Med Technol 11:66 Zimmer AM, Pavel DG (1977) Rapid miniaturized chromatographic quality control procedures for Tc-99m radiopharmaceuticals. J Nucl Med 18:1230 Physics/Radiological Protection Administration of Radioactive Substances Advisory Committee (1993) Investigations ± adult patients. In: Notes for guidance on the administration of radioactive substances to persons for purposes of diagnosis, treatment or research, Appendix 1, Part A. Administration of Radioactive Substances Advisory Committee ± ARSAC, Oxon, UK, p 25 Ibidem (1993) Investigations ± children and young persons. In: Notes for guidance on the administration of radioactive substances to persons for purposes of diagnosis, treatment or research, Appendix 1, Part D, pp 34±35 International Commission on Radiation Protection (1987) Annals of the ICRP, radiation dose to patients from radiopharmaceuticals, biokinetic models and data. ICRP publication 53, vol. 18, no. 1±4. Pergamon, Oxford International Commission on Radiation Protection (1993) Annals of the ICRP, radiological protection in biomedical research, ICRP Publication 62, vol. 22, no. 3. Pergamon, Oxford Saha GB (2000) Physics and radiobiology of nuclear medicine, 2nd edn. Springer, Berlin Heidelberg New York Young MEJ (1983) Radiological Physics, 3rd edn. Lewis, London Official Publications Council of Europe (2005) European pharmacopoeia 5.0. Maisonneuve, Sainte-Ruffine European Commission (1997) Pharmaceutical legislation ± Eudralex ± the rules governing medicinal products in the European Union. Good manufacturing practices, vol. 4. European Commission, Luxembourg, pp 70, 81±82 United States Pharmacopeial Convention (2005) United States pharmacopeia (USP) 28 ± national formulary (NF) 23
Appendix 2 Scope of COST B3: WG-1 COST is a European cooperation in the field of scientific and technical research. COST Action B3 was devoted to the development of new radiotracers for nuclear medicine application and methods of quality assurance. The main objectives of the cooperation were defined in a preparatory meeting in Vienna on 12 October 1990. Fifteen participants from six member states worked out a draft of the Memorandum of Understanding (MOU), receiving expert advice from the Austrian Ministry of Science and Research. COST Action B3 was enacted in December 1992 and ended in December 1997. Sixteen European states ± Austria, Belgium, Denmark, Finland, France, Germany, Greece, Hungary, Italy, The Netherlands, Norway, Slovenia, Spain, Sweden, Switzerland, and the United Kingdom ± signed the MOU; their national institutions participated in five Working Groups. Chairpersons 1993±1994 Dr. Ilse Zolle, M. Pharm. M. Sc., Department of Nuclear Medicine, AKH, Vienna 1994±1997 Prof. Dr. P. A. Schubiger, Paul Scherrer Institute, Center for Radiopharmaceutical Science, Villigen, CH Working Group 1 was concerned with the standardization of methods for labeling and quality control: (a) Quality control of 99mTc-radiopharmaceuticals, Coordinator F. Rakias (Hungary) (b) Standardization of radio-iodinated pharmaceuticals, Coordinator J. Mertens (Belgium) The scientific goal of Working Group 1(a) has been the development and updating of quality control methods to assure safety of 99mTc radiopharmaceuticals for parenteral application in nuclear medicine. Scientific institutions in 12 European countries have contributed their experience and results for comparison of the available analytical methods. Some results are presented in the monographs. Participating Institutions in Working Group 1(a) Austria: Department of Nuclear Medicine, Radiopharmacology, Ludwig-BoltzmannInstitute of Nuclear Medicine AKH Wien, University of Vienna Department of Nuclear Medicine, University of Innsbruck Belgium:
VUB-Cyclotron Eenheid, Vrije Universiteit Brussel Department of Radiopharmacy, Katholieke Universiteit Leuven, Leuven
Ilse Zolle, Rudolf Hæfer
Clemens Decristoforo John Mertens Alfons Verbruggen
344
Appendix 2
France:
Service Medecine Nucleaire, Centre Hospitalier, Regional et Universitaire de Tours, Tours
Denis Guilloteau
Germany:
Klinikum Berlin-Buch, Klinik fçr Nuklearmedizin, und Endokrinologie, Berlin-Buch Radiologische Klinik, Abt. f. Nuklearmedizin, Christian Albrechts Universitåt Kiel, Kiel
A. G. Bratouss
Greece:
Radiodiagnostic Products, NCSR±ªDemocritosº, Radiopharmaceuticals Section, Athens
Efstratios Chiotellis
Hungary:
Drug Quality Department, Ferenc Rakis Radiopharmaceutical Section, National Institute of Pharmacy, Budapest Frederic Joliot-Curie National Research Gyæzæ A. Jnoki Institute for Radiobiology and Radiohygiene, Department of Applied Radioisotopes, Budapest
Italy:
Department of Nuclear Medicine, Universita di Ferrara, Ferrara Department Scienze Farmaceutiche, Universita di Padova, Padua
Adriano Piffanelli
Norway:
Institut Energiteknikk, Kjeller
Per Bremer
Slovenia:
Department of Nuclear Medicine, Division of Radiochemistry, University Medical Centre Ljubljana, Ljubljana
Silvester Kladnik, Tanja Stopar
Spain:
Dpto. Technologia Pharmaceutica, Facultad Pharmacia, Universidad La Laguna, La Laguna, Tenerife
Jesus Mallol
Sweden:
Medical Products Agency, Radiopharmaceuticals, Uppsala
Trygve Bringhammar
United Kingdom:
Department of Nuclear Medicine, Addenbrooke's Hospital, Cambridge
Charles B. Sampson
Heike Wolf
Ulderico Mazzi
Publications Working Group 1 Mallol J, Bonino C (1997) Comparison of radiochemical purity control methods for technetium radiopharmaceuticals used in hospital radiopharmacy. Nucl Med Commun 18:419±422 Noll B, Johannsen B, Spies H (1995) Sources of radiochemical impurities in the 99mTc/ S-unprotected MAG3-system. Presented at the second COST B3 Workshop in Villigen (Switzerland), 6±7 October 1994. Nucl Med Biol 22:1057±1062 Sampson CB (1996) Complications and difficulties in radio-labelling blood cells: a review. Nucl Med Commun 17:648±658
Appendix 2
Rakias F, Zolle I (1997) Stannous ion determination: importance and relevance for radiopharmaceutical kits. In: Bergmann H, Kroiss A, Sinzinger H (eds) Radioactive isotopes in clinical medicine and research XXII. Birkhåuser, Basel, Switzerland, pp 401±407 Seifert S, Muth O, Jantsch K, Johannsen B (1995) Radiochemical purity of 99mTc-HMPAO: critical parameters during kit preparation. Presented at the second COST B3 workshop in Villigen (Switzerland), 6±7 October 1994. Nucl Med Biol 22:1063±1066 Solanki C, Barber R, Sampson CB (1994) Stabilization and multi-dose usage of exametazime for cerebral perfusion studies. Nucl Med Commun 15:718±722 Working Group Meetings 25 June 1993 National Institute of Pharmacy, Radiopharmaceutical Section, Budapest, Hungary 22 March 1994 National Institute of Pharmacy, Radiopharmaceutical Section, Budapest, Hungary 12 May 1995 National Institute of Pharmacy, Radiopharmaceutical Section, Budapest, Hungary 22 March 1996 Dpto. Technologia Pharmaceutica, Facultad Pharmacia, Universidad La Laguna, Tenerife, Spain Editors' Meetings In preparation of the Handbook of quality control of 99mTc-radiopharmaceuticals 5 December 1994 Department of Nuclear Medicine, Radiopharmacology, AKH Wien, Vienna, Austria 14 July 1995 National Institute of Pharmacy, Radiopharmaceutical Section, Budapest, Hungary 8 January 1996 Hotel Elisabethpark, Badgastein, Austria Short-Term Scientific Missions Jesus Mallol, Ph.D, September 1995: Comparison of radiochemical purity control methods for technetium radiopharmaceuticals used in hospital radiopharmacy. Sorin Biomedica S.p.A., Radiopharmaceutical Development, Saluggia, Italy Martina Netter, M.Sc., 3±21 June 1996: Study of methods to enhance the stability of the 99m Tc-HM-PAO complex. Addenbrooke's Hospital, Cambridge, UK
345