Modeling of Chemical Kinetics and Reactor Design
Modeling of Chemical Kinetics and Reactor Design A. Kayode Coker, Ph...
53 downloads
1276 Views
15MB Size
Report
This content was uploaded by our users and we assume good faith they have the permission to share this book. If you own the copyright to this book and it is wrongfully on our website, we offer a simple DMCA procedure to remove your content from our site. Start by pressing the button below!
Report copyright / DMCA form
Modeling of Chemical Kinetics and Reactor Design
Modeling of Chemical Kinetics and Reactor Design A. Kayode Coker, Ph.D. Lecturerer and Consultant, AKC Technology
Boston Oxford Johannesburg Melbourne New Delhi Singapore
Dedication To my wife Victoria and the boys Akin and Ebun, love and thanks.
Modeling of CHEMICAL KINETICS AND REACTOR DESIGN
Copyright © 2001 by Gulf Publishing Company, Houston, Texas. All rights reserved. Printed in the United States of America. This book, or parts thereof, may not be reproduced in any form without permission of the publisher. Gulf Publishing Company Book Division P.O. Box 2608, Houston, Texas 77252-2608 Library of Congress Cataloging-in-Publication Data (To come) ISBN 0-88415-481-5 Printed in the United States of America. Printed on acid-free paper (∞). iv
Acknowledgments I wish to express my gratitude to the following for giving their time in proofreading various sections of the text: Drs. A. A. Adesina, L. M. Rose, C. J. Mumford, and J. D. Jenkins. I am indebted to Emeritus Professor Octave Levenspiel for his encouragement and advice in some chapters of the text, and to Drs. Waldram and Singh for their comments, suggestions on safety in reaction engineering, and the inclusion of HEL safety photographs in the text. I would also like to thank Mr. Ed Steve for his comments and suggestions on scale-up of reactors, and Mr. Joseph Rivera for some of the figures in the text. I wish to express my gratitude to Drs. A. Bakker, J. B. Fasano, and V. V. Ranade for contributing to Chapter 10 (Computational Fluid Dynamics and Computational Fluid Mixing). I would like to acknowl-edge the following companies for the use of their materials: Arthur D. Little, HEL, M. W. Kellogg Ltd., Stone & Webster, Fauske & Associates, Inc., Simulation Sciences Inc., Chemineer, PROCEDE, and Absoft Corporation. I would like to express my gratitude to the following institutions for permission to reproduce their materials: Institution of Chemical Engineers (U.K.), the American Institute of Chemical Engineers and Chemical Engineering—a publication of Chemical Week Associates. I am also indebted to those whose work was drawn. I thank Dr. E. L. Smith for his comments and suggestions during the preparation of some of the chapters in the text and wish him a happy retirement. It has been a pleasure to have learned so much from him during his tenure at Aston University. Sincere gratitude to Tim Calk of Gulf Publishing Company for his direction and editing of the book, to Danette DeCristofaro and Jerry Hayes of ExecuStaff for their excellent production of the book, to Mr. Phil Carmical and Ms. Jennifer Plumley of Butterworth-Heinemann for the production of the CD-ROM. v
My thanks to Ahmed Mutawa of Saudi Aramco Shell Refinery (SASREF), an excellent student in the short course program for developing conversion table software for the book. In gratitude to the Almighty father, the Omnipotence, Omniscience, and Omnipresence. A. Kayode Coker, Ph.D.
Nippon Petroleum FCC Unit—Japan. (Courtesy M. W. Kellogg Ltd.) vi
Contents Preface ................................................................................................. xiii Introduction ........................................................................................ xvii CHAPTER ONE Reaction Mechanisms and Rate Expressions ................................ 11 Introduction 1 Typical Reaction Mechanisms 5 Reaction Mechanisms 8 Elementary and Non-Elementary Reactions 9 Types of Intermediate 10 The Arrhenius Equation and the Collision Theory 12 Transition State Theory 15 Chain Reactions 16 Catalytic Reactions 21 Guidelines to Formulating Reaction Mechanism 32 Testing Kinetic Models 34 Chain Length 37 References 58 CHAPTER TWO Thermodynamics of Chemical Reactions ....................................... 59 Introduction 59 Chemical Equilibrium 60 Criteria for Equilibrium 63 Reaction Equilibrium 64 Ideal Gas Mixtures 65 Real Gases—Ideal Gaseous Solutions 65 Real Gases 67 Liquid State 69 Determining the Fugacity and the Fugacity Coefficient 70 Partial Molar Quantities 72 Effect of Temperature on the Equilibrium Constant 74 vii
Heats of Reaction 75 Heat Capacities of Gases 80 Heats of Formation 80 References 93 Appendix 94 CHAPTER THREE Reaction Rate Expression ................................................................ 109 Introduction 109 Reaction Rate Equation 110 Reaction Orders 114 Determining the Order of Reactions 116 Empirical Rate Equations of the nth Order 129 Method of Half-Life t1/2 130 Parallel Reactions 134 Homogeneous Catalyzed Reactions 137 Autocatalytic Reactions 138 Irreversible Reactions in Series 140 First Order Reversible Reactions 146 Second Order Reversible Reactions 150 General Reversible Reactions 151 Simultaneous Irreversible Side Reaction 152 Pseudo-Order Reaction 154 Practical Measurements of Reaction Rates 155 Regression Analysis 171 Weighted Least Squares Analysis 173 Problems and Errors in Fitting Rate Models 175 References 216 CHAPTER FOUR Industrial and Laboratory Reactors ............................................. 218 Introduction 218 Batch Isothermal Perfectly Stirred Reactor 220 Semi-Batch Reactors 222 Continuous Flow Isothermal Perfectly Stirred Tank Reactor 226 Continuous Isothermal Plug Flow Tubular Reactor 227 Continuous Multiphase Reactors 230 Fluidized Bed System 232 Fluid Catalytic Cracking (FCC) Unit 234 Deep Catalytic Cracking Unit 235 Determining Laboratory Reactors 243 Guidelines for Selecting Batch Processes 254 viii
Guidelines for Selecting Batch Processes 254 References 259 CHAPTER FIVE Introduction to Reactor Design Fundamentals for Ideal Systems ............................................................................... 260 Introduction 260 A General Approach 262 Ideal Isothermal Reactors 264 Numerical Methods for Reactor Systems Design 279 Reversible Series Reactions 287 The Semibatch Reactor 306 Continuous Flow Stirred Tank Reactor (CFSTR) 312 Multi-Stage Continuous Flow Stirred Tank Reactor 327 Equal Size CFSTR In Series 334 Space Time (ST) and Space Velocity (SV) 349 Fractional Conversion, Yield, and Selectivity in Reactors 351 Relationship Between Conversion, Selectivity, and Yield 353 Plug Flow Reactor 362 Heterogeneous Tubular Reactor 371 Design Equation for Systems of Variable Density 372 Design Equations for Heterogeneous Reactions 375 Comparison of Ideal Reactors 387 CFSTR and Plug Flow Systems 396 Dynamic Behavior of Ideal Systems 400 Flow Recycle Reactor 410 References 423 CHAPTER SIX Non-Isothermal Reactors ................................................................. 424 Introduction 424 Operating Temperature, Reaction Types, and Temperature 425 Effect of Operating Parameters on Equilibrium Conversion 429 Energy Balance and Heat of Reaction 429 Energy Transferred between the System and Surroundings 434 Batch Reactor 457 Plug Flow Reactor 472 Autothermal Reactors 477 Conversion in Ammonia Synthesis 478 Two-Dimensional Tubular (Plug Flow) Reactor 492 Pressure Drop (∆P) in Tubular (Plug Flow) Reactors 494 Thermal Behaviors in Flow Systems 500 ix
Exothermic Reactions in CFSTRs 504 Thermal Behavior of a Tubular Flow Reactor 507 Variable Coolant Temperature in a CFSTR 515 Optimal Design of Non-Isothermal Reactors 518 Mimimum Reactor Volume at the Optimum Temperature Progression (OTP) of a Single CFSTR with a Reversible Exothermic Reaction 543 Optimum Reactor Size 546 References 551 CHAPTER SEVEN Fluid Mixing in Reactors ................................................................ 552 Introduction 552 Mixing and Agitation of Fluids 553 Similarity 570 Mixing Time Correlation 578 Scale-up of Mixing Systems 584 Static Mixers 597 Heat Transfer in Agitated Vessels 615 Liquid-Solid Agitation 634 Batch Heating and Cooling of Fluids 636 Design of Mixing Systems 656 References 659 CHAPTER EIGHT Residence Time Distributions in Flow Reactors ......................... 663 Introduction 663 The Residence Time Distribution Functions and their Relationships 664 Determining RTD from Experimental Tracer Curves 680 Analysis of RTD from Pulse Input 688 Residence Time Distribution for a Laminar Flow Tubular Reactor 708 E- and F-Curves for a Series of Stirred Tank Reactors 713 RTD Functions for CSTRs Where N Is Not an Integer 721 The Dispersion Model 723 Comparison of Tank In Series (TIS) and Dispersion Plug Flow (DPF) Models 746 Residence Time Distribution in a Static Mixer 747 Glossary 756 References 760 x
CHAPTER NINE Models for Non-Ideal Systems ........................................................ 762 Introduction 762 Basics of Non-Ideal Flow 762 Segregated Flow Model 764 Complete Segregation Model with Side Exits 770 Maximum Mixedness Model (MMM) 772 Effect of Micromixing on Conversion 774 References 782 CHAPTER TEN Application of Computational Fluid Dynamics and Computational Fluid Mixing in Reactors ............................ 783 Introduction 783 Theory and Fluid Flow Equations 786 Turbulence on Time-Averaged Navier-Stokes Equations 792 Time-Dependent Turbulent Mixing and Chemical Reaction in Stirred Tanks 794 References and Recommended Reading 810 Nomenclature 810 Improve Reactors Via Computational Fluid Dynamics 811 References 828 CHAPTER ELEVEN Biochemical Reaction ....................................................................... 830 Introduction 830 Kinetics of Enzyme-Catalyzed Reactions 831 Models of Enzyme Kinetics 834 Enzyme Kinetics in the Presence of an Inhibitor 851 Fermentation 853 Design of Biological Reactors 855 Vessel Design and Aspect Ratio 857 Types of Operation 863 Cell Growth 863 Modeling Biological Reactors 868 General Model for a Single Vessel 872 The Chemostat 876 Batch Fermenter 884 Fed-Batch Reactor 887 Scale-up of Bioreactors 889 Nomenclature 898 xi
Glossary 899 References 908 CHAPTER TWELVE Safety in Chemical Reaction Engineering .................................... 910 Introduction 910 Hazard Evaluation in the Chemical Process Industries 911 Hazard Assessment Procedures 916 Thermal Runaway Chemical Reaction Hazards 919 The φ-Factor 920 Onset Temperature 923 Test Instruments 926 Two-Phase Flow Relief Sizing for Runaway Reaction 950 Vent Sizing Methods 963 Discharge System 973 Inherently Safe Plants in Reactor Systems 984 Hazard and Operability Studies (HAZOP) 991 Glossary 1010 References 1018 Appendix 1022 CHAPTER THIRTEEN Scale-Up in Reactor Design .......................................................... 1034 Introduction 1034 Development and Scale-Up of Reactors 1036 Similarity Criteria 1037 Scale-Up in Relation to Various Factors 1037 Heat Effect 1038 Coefficients of Process Stability 1039 Dimensional Analysis and Scale-Up Equations 1040 Mathematical Modeling 1044 Scale-Up of a Batch Reactor 1047 Heat Transfer Model 1057 Jacket Zoning of a Batch Reactor 1065 The Outlet Temperature of a Scaled-Up Batch System 1070 Aspect Ratio (R) in Jacket Zoning and Scale-Up of a Batch Reactor 1074 Nomenclature 1079 References 1080 Nomenclature ................................................................................... 1082 Index .................................................................................................. 1089 About the Author ............................................................................ 1096 xii
Preface SCOPE This valuable reference volume conveys a basic understanding of chemical reactor design methodologies that incorporate both scale-up and hazard analysis. It shows readers how to select the best reactor for any particular chemical reaction, how to estimate its size, and how to obtain the best operating conditions. An understanding of chemical reaction kinetics and the design of chemical reactors is very important to the chemist and the chemical engineer. Engineers share interests in fluid mechanics and transport phenomena, while the chemist deals with the kinetics and mechanisms of reactions. The chemical engineer combines the knowledge of these subjects for the better understanding, design, and control of the reactor. The recent accidents that have occurred in the chemical process industries with inherent fatalities and environmental pollution have imposed greater demands on chemical engineers. Consequently, chemical reactor design methodologies must incorporate both control and hazard analysis. However, the design of chemical reactors is still essential for its proper sizing, and is included in various types of process simulators. In an industrial problem, it is essential to select the best type of reactor for any particular chemical reaction. Additionally, it is necessary to estimate its size and determine the best operating conditions. The chemical engineer confronted with the design of various reactor types often depends on the scale of operation and the kinetics. Many excellent texts have appeared over the years on chemical reactor design. However, these texts often lack sections on scale-up, biochemical reactor design, hazard analysis, and safety in reactor design methodology. The purpose of this book is to provide the basic theory and design and, sometimes, computer programs (Microsoft Excel spreadsheet and software) for solving tedious problems. This speeds up the work of both chemists and engineers in readily arriving at a solution. The following highlights some of the subjects that are covered in this text. xiii
MIXING An important unit operation in chemical reaction engineering, mixing, finds application in petrochemicals, food processing, and biotechnology. There are various types of fluid mixing such as liquid with liquid, gas with liquid, or solids with liquid. The text covers micromixing and macromixing, tracer response and residence time distribution (RTD), heat transfer, mixing fundamentals, criteria for mixing, scale of segregation, intensity of segregation, types of impellers, dimensional analysis for liquid agitation systems, design and scale-up of mixing pilot plants, the use of computational fluid dynamics (CFD) in mixing, and heat transfer in agitated vessels. BIOCHEMICAL REACTION This is an essential topic for biochemists and biochemical engineers. Biochemical reactions involve both cellular and enzymatic processes, and the principal differences between biochemical and chemical reactions lie in the nature of the living systems. Biochemists and biochemical engineers can stabilize most organic substances in processes involving microorganisms. This chapter discusses the kinetics, modeling and simulation of biochemical reactions, types and scale-up of bioreactors. The chapter provides definitions and summary of biological characteristics. CHEMICAL REACTOR MODELING This involves knowledge of chemistry, by the factors distinguishing the micro-kinetics of chemical reactions and macro-kinetics used to describe the physical transport phenomena. The complexity of the chemical system and insufficient knowledge of the details requires that reactions are lumped, and kinetics expressed with the aid of empirical rate constants. Physical effects in chemical reactors are difficult to eliminate from the chemical rate processes. Non-uniformities in the velocity, and temperature profiles, with interphase, intraparticle heat, and mass transfer tend to distort the kinetic data. These make the analyses and scale-up of a reactor more difficult. Reaction rate data obtained from laboratory studies without a proper account of the physical effects can produce erroneous rate expressions. Here, chemical reactor flow models using mathematical expressions show how physical xiv
processes interact with chemical processes. The proposed model must represent the flow behavior of an actual reactor, which is realistic enough to give useful information for its design and analysis. The text reviews different reactor flow models. SAFETY IN CHEMICAL REACTION Equipment failures or operator errors often cause increases in process pressures beyond safe levels. A high increase in pressure may exceed the set pressure in pipelines and process vessels, resulting in equipment rupture and causing major releases of toxic or flammable chemicals. A proper control system or installation of relief systems can prevent excessive pressures from developing. The relief system consists of the relief device and the associated downstream process equipment (e.g., knock-out drum, scrubber, absorbers, and flares) that handles the discharged fluids. Many chemical reactions (e.g., polymerization, sulphonation, nitration) in the chemical process industry result in runaway reactions or two-phase flow. This occurs when an exothermic reaction occurs within a reactor. If cooling no longer exists due to a loss of cooling water supply or failure of a control system (e.g., a valve), then the reactor temperature will rise. As the temperature rises, the reaction rate increases, leading to an increase in heat generation. This mechanism results in a runaway reaction. The pressure within the reactor increases due to increased vapor pressure of the liquid components and gaseous decomposition products as a result of the high temperature. Runaway reactions can occur within minutes for large commercial reactors and have resulted in severe damage to a complete plant and loss of lives. This text examines runaway reactions and two-phase flow relief. SCALE-UP The chemical engineer is concerned with the industrial application of processes. This involves the chemical and microbiological conversion of material with the transport of mass, heat and momentum. These processes are scale-dependent (i.e., they may behave differently in small and large-scale systems) and include heterogeneous chemical reactions and most unit operations. The heterogeneous chemical reactions (liquid-liquid, liquid-gas, liquid-solid, gas-solid, solid-solid) generate or consume a considerable amount of heat. However, the course of xv
such chemical reactions can be similar on both small and large scales. This happens if the mass and heat transfer processes are identical and the chemistry is the same. Emphasis in this text is on dimensional analysis with respect to the following: • Continuous chemical reaction processes in a tubular reactor. • Influence of back mixing (macromixing) on the degree of conversion and in continuous chemical reaction operation. • Influence of micro mixing on selectivity in a continuous chemical reaction process. • Scale-up of a batch reactor AN INTEGRATING CASE STUDY—AMMONIA SYNTHESIS This book briefly reviews ammonia synthesis, its importance in the chemical process industry, and safety precautions. This case study is integrated into several chapters in the text. See the Introduction for further details. Additionally, solutions to problems are presented in the text and the accompanying CD contains computer programs (Microsoft Excel spreadsheet and software) for solving modeling problems using numerical methods. The CD also contains colored snapshots on computational fluid mixing in a reactor. Additionally, the CD contains the appendices and conversion table software. A. Kayode Coker, Ph.D.
xvi
Introduction Increased collaboration between chemical reaction engineering and chemistry disciplines in recent years has produced significant advances in kinetic and thermodynamic modeling of processes. Additionally, improvement in analytical chemistry techniques, the formulation of mathematical models, and the development of computational tools have led to a deeper understanding of complex chemical reaction kinetics, particularly in mixtures with large numbers of compounds. Activities in both academic and industrial research organizations have enabled these groups to review the state of the art and cooperate with the overall objectives of improving the safety, yields, and quality of the products. Also, the final commitment to the production of any chemical product often depends on its profitability and other economic factors. Chemical kinetics mainly relies on the rates of chemical reactions and how these depend on factors such as concentration and temperature. An understanding of chemical kinetics is important in providing essential evidence as to the mechanisms of chemical processes. Although important evidence about mechanisms can be obtained by non-kinetic investigations, such as the detection of reaction intermediates, knowledge of a mechanism can be confirmed only after a detailed kinetic investigation has been performed. A kinetic investigation can also disprove a mechanism, but cannot ascertain a mechanism. Kinetic investigations cover a wide range from various viewpoints. Chemical reactions occur in various phases such as the gas phase, in solution using various solvents, at gas-solid, and other interfaces in the liquid and solid states. Many techniques have been employed for studying the rates of these reaction types, and even for following fast reactions. Generally, chemical kinetics relates to the studies of the rates at which chemical processes occur, the factors on which these rates depend, and the molecular acts involved in reaction mechanisms. Table 1 shows the wide scope of chemical kinetics, and its relevance to many branches of sciences.
xvii
Table 1 Some branches of science to which kinetics is relevant [1] Branch
Applications of kinetics
Biology
Physiological processes (e.g., digestion and metabolism), bacterial growth
Chemical engineering
Reactor design
Electrochemistry
Electrode processes
Geology
Flow processes
Inorganic chemistry
Reaction mechanisms
Mechanical engineering
Physical metallurgy, crystal dislocation mobility
Organic chemistry
Reaction mechanisms
Pharmacology
Drug action
Physics
Viscosity, diffusion, nuclear processes
Psychology
Subjective time, memory
CASE STUDY As an introduction to the modeling of chemical kinetics and reactor design, consider the manufacture of ammonia. The synthesis of ammonia is performed on a large scale with over 100 million tons produced each year. Computer simulation of the plant is increasingly employed as the first stage in identifying which parameters control the conversion rate, the product purity, the energy expended, and the production rate. The economic considerations that affect the reduction of costs with increased efficiency and profitability are high. The principal licensors of ammonia synthesis are ICI, Braun, and M.W. Kellogg. Figure 1 shows a typical ammonia plant. Ammonia is one of the largest volume inorganic chemicals in the chemical process industries. Its major applications are in the production of fertilizers, nitrates, sulfates, phosphates, explosives, plastics, resins, amines, amides, and textiles. The fertilizer industry is the largest user of ammonia, and large quantities must be stored to meet the demand and maintain constant production levels. Ammonia may be stored in very large insulated tanks at pressure near ambient; in large spheres at a moderate pressure, refrigerated to reduce the pressure; and at ambient temperature but higher pressure, corresponding xviii
xix
Figure 1. Tugas ammonia plant—Gemlik, Turkey. (Courtesy M. W. Kellogg Ltd.)
to the vapor pressure at ambient temperature. Table 2 shows the raw materials requirements, yield, and properties of ammonia. Transportation is by railroad tank vehicle, by tank truck, or by pipeline. In this case, transportation at ambient temperature is the best choice. The choice of storing ammonia at an ambient temperature liquid or partially refrigerated liquid or an ambient pressure liquid depends mostly on economic factors. One of the factors that determines the storage method is the quantity of ammonia to be stored. Ammonia is toxic and flammable, although the lower flammable limit is quite high and fires in ammonia facilities are rare. However, spillage from storage vessel or transfer piping must be considered and adequate precautions taken to minimize its effect. Storage tanks must have adequate vents so the pressure cannot rise above safe levels, and are diked to prevent the spread of liquid in case of a spill. For ambient pressure storage, the vents must be large in area and operate at pressures only slightly above ambient pressure. Alternatively, for ambient temperature, the vents are smaller, but operate at much higher pressure. At ambient temperature, ammonia in common with other liquified gases must have sufficient ullage space in the tank to allow for expansion when the temperature rises. Otherwise, liquid loaded into
Table 2 Raw materials requirements and yield Raw materials required per ton of ammonia: Natural gas: 810 m3
Yield: 85%
Properties: Colorless liquid or gas with a very pungent odor. Soluble in water, ethyl alcohol, and ether. Molecular weight: 17.03
Vapor density (air = 1): 0.597
Density at 20°C (gas): 0.771 Melting point: –77.7°C
Boiling point: –33.4°C
Autoignition temperature: 651°C Critical temperature, TC: 132.4°C Critical pressure, PC: 111.3°C Critical volume, VC: 72.4 cm3/gmol Critical compressibility factor Z: 0.243 xx
the tank from refrigerated storage will expand to cause the tank to be full of liquid as it heats. The tank vent would then open and subsequently leak liquid ammonia to the atmosphere. Training personnel for the hazardous nature of anhydrous ammonia and how to handle emergency conditions in the plant is essential. The American Conference of Government Industrial Hygienists (ACGIH) has established threshold doses called the threshold limit values (TLVs) for many chemical agents. The TLV is the airborne concentration that corresponds to conditions where no adverse effects are normally expected during a worker’s lifetime. The exposure is assumed to occur only during normal working hours, eight hours per day and five days per week. TLVs are calculated using ppm (parts per million by volume), mg/ m3 (mg of vapor per cubic meter of air). For vapor, mg/m3 is converted to ppm by the equation: C ppm = Conc. in ppm =
22.4 T 1 mg , M W 273 P m 3
T mg = 0.08205 , P • M W m3 where T = temperature in K P = absolute pressure in atm MW = molecular weight in gm/gm – mole Table 3 gives the threshold limit value (TLV) and permissible exposure level (PEL) of ammonia. Table 3
Substance
Threshold Limit Value (TLV), time weighted ppm
Ammonia
25
Value average, mg/m3 at 25°C
U.S. Safety and Administration Permissible Exposure Level (PEL), ppm
OSHA Exposure, mg/m3 at 25°C
18
25
18
xxi
The raw material source for ammonia plants is natural gas for producing hydrogen by steam reforming. An alternative raw material is naphtha, which also requires partial oxidation. Hydrogen streams from catalytic reformers are another source of hydrogen. However, the volumes available are negligible to meet the requirements of an average size ammonia plant. Nitrogen is obtained by the liquefaction of air or from producer gas mixed with hydrogen in the mole ratio of 3:1. The synthesis of ammonia is divided into four stages. In stage 1, the natural gas undergoes catalytic reforming to produce hydrogen from methane and steam. The nitrogen required for ammonia production is introduced at this stage. Stage 2 involves the "synthesis gas" (syngas) that is purified by removing both carbon monoxide and carbon dioxide. Stage 3 is the compression of the syngas to the required pressure. Stage 4 is the ammonia loop. A typical feed stock for ammonia synthesis is 0.17 million standard cubic meter per day (6 Mscfd) of natural gas at a temperature of 16°C and a pressure of 23.4 barg. Table 4 shows its composition. Natural gas is desulfurized because sulfur has an adverse effect on the catalysts used in the reforming and synthesis reactions. After desulfurization and scrubbing, the natural gas is mixed with superheated steam at 23 barg and 510°C. Nitrogen is supplied from the air, which is fed to the secondary reformer at 20 barg and 166°C. Table 5 shows the composition of air.
Table 4 Natural gas feed Component
Mole %
Carbon dioxide (CO2) Nitrogen (N2) Methane (CH4) Ethane (C2H6) Propane (C3H8) Butane (C4H10) Pentane (C5H12)
2.95 3.05 80.75 7.45 3.25 2.31 0.24
Used with permission from Simulation Sciences Inc.
xxii
Table 5 Air feed Component
Mole %
Oxygen (O2) Nitrogen (N2) Argon (Ar)
21.0 78.05 0.95
STAGE 1: CATALYTIC REFORMING After the removal of sulfur, the primary steam reformer converts about 70% of the hydrocarbon feed into synthesis gas. Methane is mixed with steam and passed over a nickel catalyst. The main reforming reactions are:
CH 4 + H 2 O CO + H 2 O
[ CO + 3H 2
[ CO2 + H 2
The catalytic steam hydrocarbon reforming process produces raw synthesis gas by steam reforming under pressure. The reactions are endothermic, thus the supply of heat to the reformer is required to maintain the desired reaction temperature. The gases leaving the reformer are CH4, 6 mol/%; CO, 8%; CO2, 6%; H2, 50%; and H2O, 30%. The operating pressure is between 20–35 bar, and the gases leaving the reformer contain about 6% CH4. This represents approximately 30% of the original natural gas input. Figure 2 shows the process flowsheet of catalytic reforming. In the secondary reformer, air is introduced to supply the nitrogen required for the 3:1 hydrogen H2 and nitrogen N2 synthesis gas. The heat of combustion of the partially reformed gas supplies the energy to reform the remaining hydrocarbon feed. The reformed product steam is employed to generate steam and to preheat the natural gas feed. STAGE 2: SHIFT AND METHANATION CONVERSION The shift conversion involves two stages. The first stage employs a high-temperature catalyst, and the second uses a low-temperature catalyst. The shift converters remove the carbon monoxide produced in the reforming stage by converting it to carbon dioxide by the reaction xxiii
Figure 2. Catalytic reforming flowsheet. (Used with permission of Simulation Sciences Inc.)
CO + H 2 O
[ CO2 + H 2
The reaction produces additional hydrogen for ammonia synthesis. The shift reactor effluent is cooled and the condensed water is separated. The gas is purified by removing carbon dioxide from the synthesis gas by absorption with hot carbonate, Selexol, or methyl ethyl amine (MEA). After purification, the remaining traces of carbon monoxide and carbon dioxide are removed in the methanation reactions. CO + 3H 2 CO 2 + 4 H 2
[ CH 4 + H 2O [ CH 4 + 2H 2O
Figure 3 illustrates the shift and methanation conversion. The resulting methane is inert and the water is condensed. Thus purified, the hydrogen-nitrogen mixture with the ratio of 3H2 : 1N2 is compressed to the pressure selected for ammonia synthesis. STAGE 3: COMPRESSION PROCESS The purified synthesis gas is cooled and the condensed water is removed. The syngas is then compressed in a series of centrifugal xxiv
Figure 3. Shift and methanation process flow diagram. (Used with permission of Simulation Sciences Inc.)
compressors with interstage cooling to a pressure of 150 bar. The centrifugal compressors are driven by steam turbines using steam generated in the plant itself. This reduces the overall power consumption. Coker [2] illustrates the design of a centrifugal compressor. Figure 4 shows the compressor with interstage cooling. STAGE 4: CONVERSION UNIT The compressed synthesis gas is dried, mixed with a recycle stream, and introduced into the synthesis reactor after the recycle compressor. The gas mixture is chilled and liquid ammonia is removed from the secondary separator. The vapor is heated and passed into the ammonia converter. The feed is preheated inside the converter prior to entering the catalyst bed. The reaction occurs at 450–600°C over an iron oxide catalyst. The ammonia synthesis reaction between nitrogen, N2, and hydrogen, H2, is N 2 + 3H 2
[ 2NH3
The reaction is an equilibrium reaction that is exothermic. Lower temperatures favor the production of ammonia. High pressures in xxv
Figure 4. Compressors with interstage cooling. (Used with permission of Simulation Sciences Inc.)
excess of 21 bar are required to achieve sufficient conversion. Conversions of 20%–25% ammonia per pass are achieved. However, the conversion of hydrogen per pass is still less than 30%, therefore, the process requires a large recycle of unreacted gases. The converted vapor product is cooled by ammonia refrigeration in the primary separator to condense the ammonia product. A purge is removed from the remaining gases to prevent the buildup up of inerts (in particular, CH4 and Ar) in the synthesis reactor. Figure 5 shows the process flow diagram of the conversion and Figure 6 illustrates the complete ammonia plant process flow diagram. Recently, the price of ammonia has nearly doubled as global supplies have been tightened and are now in line with the demands. Ammonia process licensors are employing new technologies that can be retrofitted to existing plants to increase the capacity by 20%–40% [3]. A wide range of newer more reactive catalysts are now replacing the iron-based catalysts. These catalysts are found to be advantageous in operating at lower synthesis pressures. Iron-titanium metals, rutheniumalkali metals, or ruthenium promoted by potassium and barium on activated carbon have exhibited high efficiency. The raw material hydrogen must be free from the oxides of carbon, which degrade the catalyst activity. Additionally, phosphorus, sulfur, and arsenic compounds tend to poison the catalyst in the subsequent reaction. xxvi
Figure 5. Process flow diagram of the conversion unit. (Used with permission of Simulation Sciences Inc.)
Figure 6. A complete ammonia plant process flow diagram. (Used with permission of Simulation Sciences Inc.) xxvii
M. W. Kellogg has developed a new technology in the synthesis of ammonia. They employ a ruthenium on graphite as the catalyst on Kellogg Advanced Ammonia Process (KAAP). The process is the first to employ a non-iron based catalyst and was co-developed with British Petroleum Ventures. The KAAP has been commercialized since 1994, and has been used in an increasing number of projects. Process technology licensors have developed alternative techniques to the primary and secondary reformer processes. These technologies integrate process units with steam and power systems, thereby using heat exchange networks to capture waste heat. Additionally, they provide the energy required for reforming methane. M.W. Kellogg has employed a system where the desulfurized natural gas and steam are first divided into two streams and heated. The mixed feed is then fed to a tubular reforming exchanger and an autothermal reformer. Enriched air at 600°C is then passed to the autothermal reformer and the effluent at 1,000°C flows to the shell side of the reforming heat exchanger. In the autothermal reformer, which contains conventional secondary
Figure 7. Kellogg’s new ruthenium-catalyst based advanced ammonia process combined with the reforming exchange system. (Used with permission of Chemical Engineering.) xxviii
Figure 8. Designs of ammonia synthesis converters (a) Principle of the autothermal ammonia synthesis reactor; (b) Radial flow converter with capacities of 1,800 tpd; (c) Horizontal three-bed converter and detail of the catalyst cartridge. ( Source: Walas, M. S., Chemical Process Equipment, Selection and Design, Butterworth Series in Chemical Engineering, 1988.) xxix
reforming catalyst, the feed gas is partially oxidized. The mixed stream is then sent to the reforming exchanger consisting of tubes filled with catalysts. This is designed to minimize the buildup of pressure and to expand separately without any constraint. Finally, the heat for reforming comes from an autothermal reformer effluent. Figure 7 shows the designs features in an integrated system. Figure 8 shows a selection of ammonia reactors.
REFERENCES 1. Laidler, K. J. Chemical Kinetics, 3rd ed., Harper Collins Publisher, 1987. 2. Coker, A. K., “Selecting and Sizing Process Compressors,” Hydrocarbon Processing, pp. 39–47, July 1994. 3. Shaley, A. and Ondrey, G., “Ammonia's on the Upswing,” Chemical Engineering, pp. 30–35, November 1996.
xxx
Reaction Mechanisms and Rate Expressions
1
CHAPTER ONE
Reaction Mechanisms and Rate Expressions INTRODUCTION The field of chemical kinetics and reaction engineering has grown over the years. New experimental techniques have been developed to follow the progress of chemical reactions and these have aided study of the fundamentals and mechanisms of chemical reactions. The availability of personal computers has enhanced the simulation of complex chemical reactions and reactor stability analysis. These activities have resulted in improved designs of industrial reactors. An increased number of industrial patents now relate to new catalysts and catalytic processes, synthetic polymers, and novel reactor designs. Lin [1] has given a comprehensive review of chemical reactions involving kinetics and mechanisms. Conventional stoichiometric equations show the reactants that take part and the products formed in a chemical reaction. However, there is no indication about what takes place during this change. A detailed description of a chemical reaction outlining each separate stage is referred to as the mechanism. Mechanisms of reactions are based on experimental data, which are seldom complete, concerning transition states and unstable intermediates. Therefore, they must to be continually audited and modified as more information is obtained. Reaction steps are sometimes too complex to follow in detail. In such cases, studying the energy of a particular reaction may elucidate whether or not any intermediate reaction is produced. Energy in the form of heat must be provided to the reactants to enable the necessary bonds to be broken. The reactant molecules become activated because of their greater energy content. This change can be referred to as the activated complex or transition state, and can be represented by the curve of Figure 1-1. The complex is the least stable state through 1
2
Modeling of Chemical Kinetics and Reactor Design
Figure 1-1. Potential energy curve for an exothermic reaction.
which the reactants pass before forming the products. The amount of energy required to raise the reactant molecules to this state is known as the activation energy, Ea. This energy is important in determining the rate at which a reaction proceeds. The use of a catalyst affects the rate of reaction by enabling the products to form by an alternative route. Each stage has lower activation energy than the uncatalyzed reaction. Once the reactants have absorbed sufficient energy to cross over this peak, energy is then released as the new bonds are made in yielding the stable products. For reactions at constant pressure, the difference between the amount of energy provided to break the bonds of the reactants and that evolved during the formation of new molecules is termed the enthalpy of reaction, ∆HR. When more energy is evolved than absorbed, the reaction is exothermic, that is, ∆HR is negative as shown in Figure 1-1. Alternatively, when less energy is evolved than absorbed, the reaction is endothermic, that is, ∆HR is positive as indicated by Figure 1-2. Products formed through an exothermic reaction have a lower energy content than the reactants from which they are formed. Alternatively, products formed via an exothermic process have a higher
Reaction Mechanisms and Rate Expressions
3
Figure 1-2. Potential energy curve for an endothermic reaction.
energy content than their reactants. In general, exothermic compounds are more stable than endothermic compounds. There are cases where the activated complex exists as an unstable intermediate. This is observed in reaction profile as a trough in the activated peak of the curve. This produces a double hump and as the minimum in the trough is more marked, that is, as the intermediate becomes more stable, it becomes more difficult to separate the intermediate from the reaction mixture during the course of the reaction. Figure 1-3 shows the curve of an unstable intermediate. Generally, all practical reactions occur by a sequence of elementary steps that collectively constitute the mechanism. The rate equation for the overall reaction is developed from the mechanism and is then used in reactor design. Although there are cases where experimental data provide no information about intermediate chemical species, experimental data have provided researchers with useful guidelines in postulating reaction mechanisms. Information about intermediate species is essential in identifying the correct mechanism of reaction. Where many steps are used, different mechanisms can produce similar forms of overall rate expression. The overall rate equation is the result
4
Modeling of Chemical Kinetics and Reactor Design
Figure 1-3. Potential energy curve for reactions showing the unstable intermediate state.
of the correct mechanism and is developed in terms of concentrations of the reactants and products. In the case of complex chemical reactions, the overall rate equation may be erroneous for reactor design. Therefore, assumptions are employed to make a satisfactory kinetic representation resulting in the design of a reliable reactor. Chemists and engineers interpret the mechanisms in different ways. The chemist defines the reaction mechanism as how the electron densities around the molecule move in order to provide charged areas, allowing the second reactant to attach because of induced opposite charge. The activated complex has a modified electron structure that results in part of the complex being weakly attached, thereby making detachment possible. The overall rearrangement of the charges around the molecules gives the product of the reaction. The chemical engineer, on the other hand, often views the mechanism in terms of its reaction steps, where each step changes from one distinct chemical species to another. This reduces the reaction mechanism so that it can be treated quantitatively. The following describes many types of reaction mechanisms with a view toward developing their overall rate expressions.
Reaction Mechanisms and Rate Expressions
5
TYPICAL REACTION MECHANISMS CRACKING OF ALKANES (Paraffins CnH2n+2) Pyrolysis of alkanes is referred to as cracking. Alkanes from the paraffins (kerosene) fraction in the vapor state are passed through a metal chamber heated to 400–700°C. Metallic oxides are used as a catalyst. The starting alkanes are broken down into a mixture of smaller alkanes, alkenes, and some hydrogen. − 700 C Alkanes 400 → Smaller alkanes + alkenes + H 2 o
For example: − 700 C 2CH 3CH 2 CH 3 400 → CH 4 + CH 3CH = CH 2 + CH 2 = CH 2 + H 2 (1-1) o
Propene
Ethene
Mechanism The reaction proceeds via a free radical mechanism with homolytic fission occuring between the carbon-carbon atoms. The mechanism of reactions for the cracking of propane is: Chain initiation: 1. CH 3CH 2 − CH 3 → CH 3CH∗2 + CH∗3
(1-2)
Chain propagation: 2. CH 3CH*2 → CH 2 = CH 2 + H*
(1-3)
˙ 3. CH 3CH 2 CH 3 + H* → H 2 + CH 3CHCH 3 ˙ 4. CH CH CH + CH* → CH + CH CHCH
(1-4)
3
2
3
3
4
3
3
(1-5)
Chain termination: 5. 2CH 3CH∗2 → CH 2 = CH 2 + CH 3CH 3 ˙ 6. 2CH 3CHCH 3 → CH 3CH = CH 2 + CH 3CH 2 CH 3
(1-6) (1-7)
6
Modeling of Chemical Kinetics and Reactor Design
SULFUR DIOXIDE OXIDATION The overall stoichiometric equation is:
SO 2 +
1 O2 2
[ SO3
(1-8)
Mechanism Vanadium pentoxide, V2O5, is used as a catalyst in the oxidation of sulfur dioxide. The mechanism involves oxidation-reduction of V2O5 that exists on the support at operating conditions in the molten state. The mechanism of reaction is: 1. SO 2 + 2 V 5 + + O 2 −
[ SO3 + 2V 4 +
[
]
1 O 2 + V 4 + [ V 5 + + O 2− 2 1 − 3. O 2 + V 4 + [ V 5 + + 2O − 2
2.
[
4. O − + V 4 +
(1-9) (1-10)
]
[ V 5+ + O2 −
(1-11) (1-12)
AMMONIA SYNTHESIS The overall stoichiometric equation is:
1 3 N 2 + H 2 → NH 3 2 2
(1-13)
Studies of ammonia synthesis on iron catalyst suggest that the reaction occurs through surface imine radicals. Mechanism The following elementary steps are: 1. N2(g) → 2N(ads)
(1-14)
2. H2(g) → 2H(ads)
(1-15)
3. N(ads) + H(ads) → NH(ads)
(1-16)
Reaction Mechanisms and Rate Expressions
7
4. NH (ads) + H (ads) → NH 2(ads) 5. NH 2(ads) + H (ads) → NH 3(ads)
(1-17)
6. NH 3(ads) → NH 3( g )
(1-19)
(1-18)
The “ads” denotes the adsorbed species. AMMONIA OXIDATION The overall stoichiometric reaction for the oxidation of ammonia to nitric oxide is: 4 NH 3 + 5O 2 → 4 NO + 6H 2 O
(1-20)
This reaction is very rapid and has been difficult to study mechanistically. The direct oxidation of ammonia, NH3, to nitric oxide, NO, over platinum catalyst is one of the major steps in the manufacture of nitric acid, HNO3. Mechanism 1. O 2 → 2O∗
(1-21)
2. NH 3 + O∗ → NH 2 OH ∗
3. NH 2 OH → NH + H 2 O ∗
4. NH + O 2 → HNO 2 5. HNO 2 → NO + OH ∗
∗
6. 2OH → H 2 O + O
∗
(1-22) (1-23) (1-24) (1-25) (1-26)
The oxygen is chemisorbed on the catalyst. This then reacts with ammonia to produce a chemisorbed imide radical. The imide reacts with a molecular oxygen to yield nitric oxide. STEAM REFORMING Steam reforming is an important process to generate hydrogen for such uses as ammonia synthesis because of the high endothermic heat reaction and its rapidity. High heat fluxes with a direct-fired furnace are required. Although many steps of reactions are possible, the typical reaction steps are as follows:
8
Modeling of Chemical Kinetics and Reactor Design
1. CH 4 + H 2 O → 3H 2 + CO
(1-27)
2. CH 4 + 2 H 2 O → 4 H 2 + CO 2
(1-28)
3. CO + H 2 O → CO 2 + H 2
(1-29)
4. CH 4 + CO 2 → 2CO + 2 H 2
(1-30)
5. CO + H 2
(1-31)
[ C + H2O
[ C + 2H 2 2CO [ C + CO 2
6. CH 4
(1-32)
7.
(1-33)
BIOCHEMICAL REACTION: CONVERSION OF GLUCOSE TO GLUCONIC ACID The fermentation of glucose to gluconic acid involves oxidation of the sugar in the aldehyde group (RCHO), thereby converting it to a carboxyl group (RCOOH). The conversion process is achieved by a micro-organism in the fermentation process. The enzyme glucose oxidase that is present in the micro-organism converts the glucose to gluconolactone. The gluconolactone is further hydrolyzed to form the gluconic acid. The enzyme glucose oxidase is useful in medicinal applications where glucose or oxygen removal is required. This enzyme prevents the browning reaction, or a Mailland reaction, when dried egg powders are darkened due to a reaction between glucose and protein. Also, the presence of oxygen in the production and storage of orange soft drinks, dried food powders, canned beverages, salad dressing, and cheese slices can be avoided by adding glucose oxidase. Since the activity of the enzyme is maintained for a long time at storage temperature, such enzyme additions increase the shelf-life of food products. This is achieved by the removal of oxygen that diffuses through food packaging [2]. The hydrogen peroxide produced in the glucose oxidase catalyzed reaction has an antibacterial action. The addition of a catalase catalyzes the decomposition of hydrogen peroxide to water and oxygen.
REACTION MECHANISMS The reaction mechanisms in the fermentation of glucose to gluconic acid are:
Reaction Mechanisms and Rate Expressions
9
1. Cell growth: Glucose + cells → more cells That is: C6H12O6 + cells → more cells
(1-34)
2. Glucose oxidation: Glucose + O 2 → gluconolactone + H 2 O Glucose oxidase
That is:
C 6 H12 O 6 + O 2 → C 6 H10 O 6 + H 2 O 2 Glucose oxidase
(1-35)
3. Gluconolactone hydrolysis: Gluconolactone + H 2 O → gluconic acid
That is: C 6 H10 O 6 + H 2 O → C 5H11O 5COOH
(1-36)
4. Hydrogen peroxide decomposition: H 2 O 2 Catalase → H 2 O +
1 O2 2
(1-37)
Analysis of the rate equation and kinetic model of the conversion of glucose to gluconic acid is discussed in Chapter 11.
ELEMENTARY AND NON-ELEMENTARY REACTIONS Consider the reaction between hydrogen and bromine in the gas phase: H 2 + Br2 → 2 HBr
(1-38)
Bodenstein and Lind [3] first studied the thermal reaction over the temperature range of 500–600 K. The relative reaction rates of hydrogen and bromine and the formation of hydrogen bromide are:
10
Modeling of Chemical Kinetics and Reactor Design
(− r ) = (− r ) H2
Br2
=
1 (+ rHBr ) 2
(1-39)
and, if the reaction took place in a single step, then the rate expression may be represented as:
(+ rHBr ) = k C H 2 C Br2
(1-40)
The slope of a concentration-time curve to define the rate expression can be determined. However, experimental studies have shown the reaction cannot be described by simple kinetics, but by the relationship: k1C H 2 C 0Br.52 (+ rHBr ) = C k 2 + HBr C Br2
(1-41)
where k1 and k2 are the rate constants. The reaction between hydrogen and bromine is an example of a non-elementary reaction. The following steps account for the rate expression: Br2 → 2 Br *
(1-42)
Br * + H 2 → HBr + H*
(1-43)
H* + HBr → Br * + H 2
(1-44)
Br* and H* being highly reactive intermediates.
TYPES OF INTERMEDIATE STABLE INTERMEDIATES Stable intermediates are those where concentration and lifespan are comparable to those of stable reactants and products. An example is the reaction between methane and oxygen in the gas phase at 700 K and 1 atmosphere. The overall reaction is: CH 4 + 2 O 2 → CO 2 + 2 H 2 O
(1-45)
Reaction Mechanisms and Rate Expressions
11
Successive single reactions are: CH 4 + O 2 → CH 2 O + H 2 O
(1-46)
(Formaldehyde)
CH 2 O + O 2 → CO + H 2 O 2
(1-47)
1 CO + O 2 → CO 2 2
(1-48)
1 H 2O2 → H 2O + O2 2
(1-49)
In these reactions, the stable intermediates are CH2O, CO, and H2O2. ACTIVE CENTERS Reactions that are catalyzed by solids occur on the surfaces of the solids at points of high chemical activity. Therefore, the activity of a catalytic surface is proportional to the number of active centers per unit area. In many cases, the concentration of active centers is relatively low. This is evident by the small quantities of poisons present (material that retards the rate of a catalytic reaction) that are sufficient to destroy the activity of a catalyst. Active centers depend on the interatomic spacing of the solid structure, chemical constitution, and lattice structure. Generally, active centers are highly reactive intermediates present in very small concentrations with short lifespans. For example, in the case of
H 2 + Br2 → 2 HBr
(1-50)
H* and Br* and in the case of CH 3CHO → CH 4 + CO
CH∗3 , CHO∗ , CH 3CO∗
(1-51)
12
Modeling of Chemical Kinetics and Reactor Design
TRANSITION STATE INTERMEDIATES Each elementary step proceeds from reactants to products through the formation of an intermediate called the transition state. Such intermediates cannot be isolated, as they are species in transit. The act of reaction will involve the breaking or making of a chemical bond, whereby transition state intermediates are formed (see also “Transition State Theory”).
THE ARRHENIUS EQUATION AND THE COLLISION THEORY THE ARRHENIUS EQUATION Generally, the rate of reaction depends on three principal functions: temperature, pressure, and composition. However, as a result of phase rule and thermodynamics, there is a relationship between temperature, pressure, and composition. This relationship can be expressed as:
ri = f ( temperature, composition)
(1-52)
Consider the reaction: A+B→C+D
(1-53)
Here, a molecule of C is formed only when a collision between molecules of A and B occurs. The rate of reaction rC (that is, rate of appearance of species C) depends on this collision frequency. Using the kinetic theory of gases, the reaction rate is proportional to the product of the concentration of the reactants and to the square root of the absolute temperature: rC ∝ C A C BT 0.5
(1-54)
The number of molecules reacting per unit time is smaller than the number of binary collisions between A and B. Also, temperature is known to have a much greater effect on the reaction rate than one would expect from T0.5. For binary collisions between A and B to result in a reaction, the collision must involve energies of translation and vibration that are in excess of energy E, known as the activation
Reaction Mechanisms and Rate Expressions
13
energy. The fraction of collisions having energies in excess of E is represented by e–E/RT, which can now be substituted in Equation 1-54 to give: rC ∝ e − E RT C A C BT 0.5
(1-55)
The effect of temperature in T0.5 is small compared with its effect in e–E/RT; therefore, T 0.5 can be combined with the proportionality constant resulting in: rC = k O e − E RT C A C B
(1-56)
Generally, ri = f1 (temperature) f2 (composition) and at a given temperature: ri = k f2 (composition)
(1-57)
where k = k O e − E RT where k ko E R T
= = = = =
(1-58)
reaction rate constant or velocity constant frequency factor or preexponential factor activation energy, J/mol or cal/mol gas constant = 8.314 J/mol•K = 1.987 cal/mol•K absolute temperature, K
Equation 1-58 is referred to as the Arrhenius equation. Effect of Temperature on Reaction Rates We can evaluate the effect of temperature on the reaction rate from the Arrhenius equation, k = koe–E/RT, as: ln k = ln k O −
E RT
(1-59)
When plotting experimentally determined reaction rate constants as a function of temperature (i.e., ln k against 1/T), a straight line is obtained with –E/R equal to the slope and the intercept as ln ko. Figure 1-4 shows the linear relationship between the reaction rate constant and the temperature.
14
Modeling of Chemical Kinetics and Reactor Design
Figure 1-4. Reaction rate temperature dependence.
THE COLLISION THEORY The collision theory for bimolecular reactions assumes that a chemical reaction occurs when two molecules collide with enough energy to penetrate the molecular van der Waals repulsive forces, thus combining together. For the bimolecular collisions of unlike molecules A, the collision number is: 4 πkT Z AA = σ 2A n 2A MA =
0.5
= σA
N2 10 6
4 πkT MA
0.5
number of collisions of A with A sec• cm 3
C 2A (1-60)
For bimolecular collisions of unlike molecules in a mixture of A and B, A + B → Products
Reaction Mechanisms and Rate Expressions
σ + σB 2 M + MB Z AB = A n A • n B 8πkT • A MA • MB 2 σ + σB 2 N2 = A 2 10 6 where σ M N CA CB nA nB k
= = = = = = = =
MA + MB 8πkT • M A .M B
15
0.5
(1-61)
0.5
CACB
diameter of a molecule, cm (molecular weight)/N, mass of a molecule, gm 6.023 × 1023 molecules/mol, Avogadro’s number concentration of A, mol/l concentration of B, mol/l NCA/103, number of molecules of A/cm3 NCB/103, number of molecules of B/cm3 R/N = 1.30 × 10–16 erg/K, Boltzmann constant
The rate equation is given by
(− rA ) = − V1
dN A = kC A C B dt fraction of collision collision rate = involving energies mol / l • sec in excess of E
(1-62)
where E is the minimum energy. = Z AB • =
10 3 − E RT e N
σA + σB 2 N M + MB 8πkT • A 3 2 10 MA MB
0.5
C A C B e − E RT
(1-63)
where e–E/RT represents the fraction of collisions involving molecules with the necessary activation energy E.
TRANSITION STATE THEORY The transition state theory describes reactants combining to form unstable intermediates called activated complexes, which rapidly
16
Modeling of Chemical Kinetics and Reactor Design
decompose into products. This is represented by the following reaction steps: A+B→P
(1-64)
A + B [ AB* → P
(1-65)
Transition state intermediate
The overall rate of reaction depends on the rate of decomposition of AB* to product P. The collision theory considers the rate to be governed by the number of energetic collisions between the reactants. The transition state theory considers the reaction rate to be governed by the rate of the decomposition of intermediate. The formation rate of the intermediate is assumed to be rapid because it is present in equilibrium concentrations.
CHAIN REACTIONS Atoms and free radicals are highly reactive intermediates in the reaction mechanism and therefore play active roles. They are highly reactive because of their incomplete electron shells and are often able to react with stable molecules at ordinary temperatures. They produce new atoms and radicals that result in other reactions. As a consequence of their high reactivity, atoms and free radicals are present in reaction systems only at very low concentrations. They are often involved in reactions known as chain reactions. The reaction mechanisms involving the conversion of reactants to products can be a sequence of elementary steps. The intermediate steps disappear and only stable product molecules remain once these sequences are completed. These types of reactions are referred to as open sequence reactions because an active center is not reproduced in any other step of the sequence. There are no closed reaction cycles where a product of one elementary reaction is fed back to react with another species. Reversible reactions of the type A + B [ C + D are known as open sequence mechanisms. The chain reactions are classified as a closed sequence in which an active center is reproduced so that a cyclic reaction pattern is set up. In chain reaction mechanisms, one of the reaction intermediates is regenerated during one step of the reaction. This is then fed back to an earlier stage to react with other species so that a closed loop or
Reaction Mechanisms and Rate Expressions
17
cycle is formed. The intermediate species are intermittently formed by the reaction, and the final products are the result of a cyclic repetition of the intervening processes. Chain reactions play active roles in industrial processes. Bodenstein [4] first suggested the idea of a chain reaction by postulating that ions such as chlorine, Cl+2, are chain carriers. Later, Nernst [5] proposed his mechanism for the hydrogen in chlorine reaction that gave rise to the idea that organic free radicals are important in reaction mechanisms. Taylor [6] investigated the reactions of hydrogen atoms with various substances. He proposed a reaction between a hydrogen atom and ethane. The resulting ethyl radical plays an important role in hydrocarbon reactions. Rice and Herzfeld [7] postulated reaction schemes involving the participation of free radicals in the pyrolysis of organic compounds. Techniques such as spectroscopy, electron-spin resonance spectroscopy, and mass spectrometry have confirmed the validity of these types of reaction mechanism. They confirmed that free radicals are important in many reactions, and thus act as chain carriers. Chain reactions are involved in such processes as combustion, polymerization, and photochemical processes. A chain reaction consists of three main steps: 1. Initiation (or activation) 2. Propagation (closed sequence steps) 3. Termination The reaction between hydrogen and bromine is the first step in the initiation reaction in which the chain carriers are formed. The thermal hydrogen bromine reaction begins with the initiation reaction: Br2 → Br * + Br *
(1-66)
This is followed by chain propagation reactions: Br * + H 2 → HBr + H*
(1-67)
H* + Br2 → HBr + Br *
(1-68)
H* + HBr → H 2 + Br *
(1-69)
The termination reaction is the removal of the carrier from the system:
18
Modeling of Chemical Kinetics and Reactor Design
Br * + Br * → Br2
(1-70)
The Rice-Herzfeld mechanisms of reaction are: 1. Initiation • Free radicals are formed by scission of the weakest bond in the molecule. 2. Propagation • One or both of the radicals formed in the initiation step abstracts a hydrogen atom from the parent compound to form a small saturated molecule and a new free radical. • The new free radical stabilizes itself by splitting out a simple molecule such as olefin or CO: RCH 2 − CH*2 → R * + CH 2 = CH 2 3. Termination • The chain is broken by a combination or disproportionation reaction between the two radicals. Employing mechanistic equations based on the Rice-Herzfeld postulation yields: 1. Initiation k
M 1 → R * + R1*
(1-71)
2. Propagation k
2 R * + M → R 2 + R *H
k
R 2 3 → R * + P1
(1-72) (1-73)
3. Termination k
4 R * + R * → P2
k
5 R * + R 2 → P3
k
6 R 2 + R 2 → P4
(1-74) (1-75) (1-76)
Reaction Mechanisms and Rate Expressions
19
The following mechanism has been postulated for the gas phase decomposition of acetaldehyde: CH 3CHO → CH 4 + CO Thermal decomposition
Acetaldehyde
Methane Carbon monoxide
Initiation k
CH 3CHO 1 → CH*3 + CHO*
(1-77)
This thermal initiation generates two free radicals by breaking a covalent bond. The aldehyde radical is long-lived and does not markedly influence the subsequent mechanism. The methane radical is highly reactive and generates most reactions. Propagation
r
k
2 CH*3 + CH 3CHO → CH 4 + CH 3CO*
k
3 CH 3CO* → CO + CH*3
(1-78) (1-79)
r
r
The propagation reactions use a methyl radical and generate another. There is no net consumption, and a single initiation reaction can result in an indefinite number of propagation reactions. Termination k
4 CH*3 + CH*3 → C2H6
(1-80)
The following mechanism has been postulated for the decomposition of ethane into ethylene and hydrogen. The overall rate expression is first order in ethane. Initiation k
C 2 H 6 1 → CH*3 + CH*3
(1-81)
20
Modeling of Chemical Kinetics and Reactor Design
Chain transfer k
2 CH*3 + C 2 H 6 → CH 4 + C 2 H*5
(1-82)
Propagation k
3 C 2 H*5 → C 2 H 4 + H*
k
4 H* + C 2 H 6 → H 2 + C 2 H*5
(1-83) (1-84)
Termination k
5 H* + C 2 H*5 → C2H6
(1-85)
High temperatures, electromagnetic radiation, ionizing radiation, or highly reactive chemical initiators often generate active centers. POLYMERIZATION KINETICS Many polymerization reactions proceed by free radical mechanisms. The following is a sequence of elementary steps for the polymerization reaction: 1. Dissociation of initiator (I) into two radical fragments k
D I → R* + R*
(1-86)
2. Addition of initiator monomer M k
R * + M i → RM*
(1-87)
3. Chain propagation k
P RM* + M → RMM*
k
p RMM* + M → RMMM*
k
P RMMM* + M → RMMMM*
(1-88) (1-89) (1-90)
Reaction Mechanisms and Rate Expressions
21
4. Chain termination (a) Radical combination tc R(M )*m + R(M )n → R( M ) m ( M ) n R
k
(1-91)
(b) Radical disproportionation tD R(M )*m + R(M )n → saturated polymer
k
+ unsaturated polymer
(1-92)
CATALYTIC REACTIONS ENZYME CATALYZED REACTIONS Enzymes are proteins of high molecular weight and possess exceptionally high catalytic properties. These are important to plant and animal life processes. An enzyme, E, is a protein or protein-like substance with catalytic properties. A substrate, S, is the substance that is chemically transformed at an accelerated rate because of the action of the enzyme on it. Most enzymes are normally named in terms of the reactions they catalyze. In practice, a suffice -ase is added to the substrate on which the enzyme acts. For example, the enzyme that catalyzes the decomposition of urea is urease, the enzyme that acts on uric acid is uricase, and the enzyme present in the micro-organism that converts glucose to gluconolactone is glucose oxidase. The three major types of enzyme reaction are: Soluble enzyme–insoluble substrate Insoluble enzyme–soluble substrate Soluble enzyme–soluble substrate The study of enzymes is important because every synthetic and degradation reaction in all living cells is controlled and catalyzed by specific enzymes. Many of these reactions are the soluble enzyme– soluble substrate type and are homogeneous in the liquid phase. The simplest type of enzymatic reaction involves only a single reactant or substrate. The substrate forms an unstable complex with the enzyme that decomposes to give the product species or, alternatively, to generate the substrate.
22
Modeling of Chemical Kinetics and Reactor Design
Using the Bodenstein steady state approximation for the intermediate enzyme substrate complexes derives reaction rate expressions for enzymatic reactions. A possible mechanism of a closed sequence reaction is:
r
k1
E + S [ ES*
(1-93)
k2
Enzyme Substrate enzyme-substrate complex k
ES* 3 → E + P
(1-94)
r
r
where E S ES* P
= = = =
enzyme substrate enzyme-substrate complex product of the reaction
The stoichiometry of the reaction may be represented as: S →P
(1-95)
The net rate of an enzymatic reaction is usually referred to as its velocity, V, represented by: V=
dC p dt
= k 3C ES*
(1-96)
The concentration of the complex can be obtained from the net rate of disappearance:
(− r )
SE * net
=−
dC SE * dt
= k 2 C SE * + k 3C SE * − k1C SC E
(1-97)
Using the steady state approximation, dC SE * dt
or
= k1C SC E − k 2 C SE * − k 3C SE * ≅ 0
(1-98)
Reaction Mechanisms and Rate Expressions
C SE * =
k1C SC E k2 + k3
23
(1-99)
Substituting Equation 1-99 into Equation 1-96 gives:
V=
k1 • k 3 • C E • C S k2 + k3
(1-100)
From the material balance, the total concentration of the enzyme in the system, CET, is constant and equal to the sum of the concentrations of the free or unbounded enzyme, CE, and the enzymesubstrate complex, CSE*, that is: C ET = C E + C SE *
(1-101)
For the substrate CS, the total concentration of the substrate in the system, CST, is equal to the sum of the concentration of the substrate and the enzyme substrate complex CSE* C ST = C S + C SE *
(1-102)
In laboratory conditions, CST k CET, since CSE* cannot exceed CET. This shows that CST ≈ CS. Rearranging Equation 1-101 gives: C E = C ET − C SE *
(1-103)
Using CST ≈ CS in Equation 1-102 and substituting Equation 1-103 into Equation 1-98 gives:
dC SE * dt
(
)
= k1C ST C ET − C SE * − k 2 C SE * − k 3C SE * ≅ 0
k1C ST C ET − k1C ST C SE * − k 2 C SE * − k 3C SE * = 0
(1-104)
or
C SE * =
k1C ST C ET k1C ST + k 2 + k 3
(1-105)
24
Modeling of Chemical Kinetics and Reactor Design
Substituting Equation 1-105 into Equation 1-96 gives
VO =
k1k 3C ST C ET dC P = dt k1C ST + k 2 + k 3
(1-106)
Equation 1-106 predicts that the initial rate will be proportional to the initial enzyme concentration, if the initial substrate concentration is held constant. If the initial enzyme concentration is held constant, then the initial rate will be proportional to the substrate concentration at low substrate concentrations and independent of the substrate concentration at high substrate levels. The maximum reaction rate for a given total enzyme concentration is Vmax = k 3C ET
(1-107)
Equation 1-106 can be rearranged to
Vo =
Vmax C ST k + k3 C ST + 2 k1
(1-108)
Equation 1-108 can be considered as the Michaelis-Menten equation, where Km is the Michaelis constant and represented as
Km =
k2 + k3 k1
(1-109)
Equation 1-108 then becomes
Vo =
Vmax C ST C ST + K m
(1-110)
Rearranging Equation 1-110 gives
Km 1 1 = + Vo Vmax Vmax C ST
(1-111)
Reaction Mechanisms and Rate Expressions
25
Equation 1-111 is known as the Lineweaver-Burk or reciprocal plot. If the data fit this model, a plot of 1/Vo versus 1/CST will be linear with a slope Km/Vmax and the intercept 1/Vmax. At low substrate concentration, Equation 1-110 becomes
Vo ≈
Vmax C ST Km
(1-112)
At high substrate concentration, C ST >> K m
and Equation 1-110 becomes VO ≈ Vmax Figure 1-5 shows a plot of 1/Vo = 1/Vmax + Km/VmaxCST.
Figure 1-5. Lineweaver-Burk plot.
26
Modeling of Chemical Kinetics and Reactor Design
ACID-BASE CATALYSIS: HOMOGENEOUS LIQUID PHASE A catalyst is defined as a substance that influences the rate or the direction of a chemical reaction without being consumed. Homogeneous catalytic processes are where the catalyst is dissolved in a liquid reaction medium. The varieties of chemical species that may act as homogeneous catalysts include anions, cations, neutral species, enzymes, and association complexes. In acid-base catalysis, one step in the reaction mechanism consists of a proton transfer between the catalyst and the substrate. The protonated reactant species or intermediate further reacts with either another species in the solution or by a decomposition process. Table 1-1 shows typical reactions of an acidbase catalysis. An example of an acid-base catalysis in solution is hydrolysis of esters by acids. R1COOR 2 + H 2 O
[
Acid
R1 COOH + R 2 OH
(1-113)
Mechanism R1COOR 2 + H +
[ (R1COOR 2 H + )*
(R1COOR 2 H + )* + H 2O [ R1COOH + R 2OH + H +
(1-114) (1-115)
AUTOCATALYTIC REACTIONS There are many reactions in which the products formed often act as catalysts for the reaction. The reaction rate accelerates as the reaction continues, and this process is referred to as autocatalysis. The reaction rate is proportional to a product concentration raised to a positive exponent for an autocatalytic reaction. Examples of this type of reaction are the hydrolysis of several esters. This is because the acids formed by the reaction give rise to hydrogen ions that act as catalysts for subsequent reactions. The fermentation reaction that involves the action of a micro-organism on an organic feedstock is a significant autocatalytic reaction. Normally, when a material reacts, its initial rate of disappearance is high and the rate decreases continuously as the reactant is consumed. However, in autocatalytic reaction, the initial rate is relatively slow
Cleavage diacetone-alcohol Hydrolysis of esters Decomposition of acetaldehyde hydrate Decomposition of nitramide Halogenation exchange racemization of ketones
Specific acid and base
General acid
General base
General acid and base
R ⋅ CO ⋅ CH 3 + X 2 = R ⋅ CO ⋅ CH 2 X + XH
NH 2 NO 2 = N 2 O + H 2 O
CH 3 ⋅ CH(OH) 2 = CH 3 ⋅ CHO + H 2 O
R1 ⋅ COOR 2 + H 2 O = R1 ⋅ COOH + R 2 OH
CH 3 CO ⋅ CH 2 ⋅ C(OH)(CH 3 ) 2 = 2(CH 3 ) 2 ⋅ CO
R1CH(OR 2 ) 2 + H 2 O = R1 ⋅ CHO + 2 R 2 OH CH 2 : CH ⋅ CHO + H 2 O = CH 2 OH ⋅ CH 2 ⋅ CHO
Hydrolysis of acetals
C12 H 22 O11 + H 2 O = C 6 H12 O 6 + C 6 H12 O 6
Equation of reaction
Hydration of unsaturated aldehydes
Inversion of cane sugar
Brief title of rearction
Specific base
Specific acid
Types of catalysis
Table 1-1 Examples of acid-base catalysis in aqueous solution Reaction Mechanisms and Rate Expressions 27
28
Modeling of Chemical Kinetics and Reactor Design
since little or no product is formed. The rate then increases to a maximum as the products are formed and then decreases to a low value as the reactants are consumed. Consider the following mechanism for an autocatalytic reaction: k
2 A 1 → B + C
(1-116)
k
(1-117)
3 2 AB → 3B + C
(1-118)
2 A + B → AB
k
where AB is an intermediate complex. The observed rate of reaction is the rate of formation of species:
(+ rC ) = k1C2A
+ k 3C 2AB
(1-119)
The concentration of the reaction intermediate AB may be determined by using the steady state approximation for intermediates,
(+ rAB ) = k 2C A C B − 2 k 3C2AB ≈ 0
(1-120)
Therefore, k C AB = 2 • C A C B 2k3
0.5
(1-121)
Substituting Equation 1-121 into Equation 1-119 gives
(+ rC ) = k1C2A + k22 C A C B
(1-122)
Therefore, the mechanism results in a rate expression in which species B is responsible for the autocatalytic behavior. GAS-SOLID CATALYTIC REACTIONS Consider a gaseous reactant flowing through a bed of solid catalyst pellets. The physical steps involved are the transfer of the component
Reaction Mechanisms and Rate Expressions
29
gases up to the catalyst surface, diffusion of reactants into the interior of the pellet, diffusion of the products back to the exterior surface, and finally the transfer of the products from the exterior surface to the main stream. Interpreting the experimental results requires minimizing the resistance offered by each of these physical processes and focusing on the chemical aspects of the reaction. The chemical procedures involve activated adsorption of reactants with or without dissociation, surface reactions on active sites, and activated desorption of the products. The uncatalyzed reaction also takes place in the main gas stream simultaneously with the surface reaction. In industrial applications of kinetics, an understanding of the mechanisms of chemical reactions is essential. This is helpful in establishing the optimum operating conditions in relation to parameters such as temperature, pressure, feed composition, space velocity, and the extent of recycling and conversion. Yang and Hougen [7] have established procedures in planning and correlating experimental data for gaseous reactions catalyzed by solids. They provided methods for eliminating, minimizing, or evaluating the temperatures and concentration gradients in gas films and catalyst pellets. Hougen and Watson [8] have developed rate equations for various mechanisms that may occur in gaseous reactions when catalyzed by solid surfaces. The following illustrates a gas-solid catalytic reaction:
30
Modeling of Chemical Kinetics and Reactor Design k1
Adsorption Step: A + x1 Surface Reaction: x 2
k2
−2
k3
(1-123)
x3
(1-124)
−1
[ k
[ k
[ x2 k
R + x1
(1-125)
A: ( − rA )net = k1C A C x1 − k −1 C x 2
(1-126)
R: ( + rR )net = k 3C x 3 − k −3 C R C x1
(1-127)
Desorption Step: x 3
−3
The rate equations are:
x 2 : + rx 2
(
)
(
)
x 3 : + rx 3
net
= k1C A C x1 + k −2 C x 3 − ( k −1 + k 2 ) C x 2
(1-128)
net
= k 2 C x 2 + k −3C x1 C R − ( k −2 + k 3 ) C x 3
(1-129)
Assume: 1. ( +rx 2 ) net and ( +rx 3 ) net are zero 2. Number of active sites remains constant, CT. Thus, C T = C x 2 + C x 3 + C x1
(1-130)
Usually, one of the elementary steps is rate controlling (that is, it is very slow relative to all the other steps). Suppose that A + x1 → x2 is the rate-controlling step and the reverse reaction is ignored, then
(− rA )net
≅ k1C A C x1
(1-131)
Under these conditions, the desorption process and surface reactions are in a pseudo-equilibrium state: k 2 C x 2 ≅ k −2 C x 3
(1-132)
Reaction Mechanisms and Rate Expressions
k 3C x 3 ≅ k −3C x1 C R
31
(1-133)
and C T = C x1 + C x 2 + C x 3
(1-134)
Rearranging Equations 1-132 and 1-133 in terms of Cx 2 and Cx 3 and substituting them in Equation 1-134 gives C T = C x1 +
k k −2 k −3 • C x1 C R + −3 C x1 C R k2 k3 k3
Therefore, C x1 =
CT 1 + KT CR
(1-135)
where k k k K T = −2 • −3 + −3 k3 k2 k3
(1-136)
Substituting Equation 1-136 into Equation 1-131 to eliminate Cx 1 , yields
(− rA )net
=
(− rA )net
=
( k1C T )C A 1 + K TCR
(1-137)
K 4C A 1 + KT CR
(1-138)
or
If the reverse step in adsorption is not ignored, then
(− rA )net
=
K 4 C A − K 5C R 1 + KT CR
(1-139)
32
Modeling of Chemical Kinetics and Reactor Design
GUIDELINES TO FORMULATING REACTION MECHANISM Guidelines have been proposed within which the kineticist works in developing a reaction mechanism. Edward et. al [9] have collated the most extensive collection of guidelines (see Chapter 3), which enable a kineticist to judge the feasibility of a proposed mechanism. They also allow the elimination of a proposed sequence of reactions as being unreasonable from the experimental data. The following are the guidelines to formulating reaction mechanism. 1. The most fundamental basis for mechanistic speculation is a complete analysis of the reaction products. It is essential to obtain a complete quantitative and qualitative analysis for all products of the reaction. Such analyses can provide essential clues as to the identity of the reaction intermediates. 2. The atomic and electronic structure of the reactants and products may point to the nature of possible intermediate species. The structural arrangement of atoms in the molecules that react must correspond at the instant of reaction to interatomic distances appropriate for the formation of new species. 3. All of the elementary reactions involved in a mechanistic sequence must be feasible with respect to bond energies. Bond energy considerations also may conclude that highly endothermic elementary reactions will be slow processes because of the large activation energies normally associated with these reactions. 4. The number of elementary reactions employed must be sufficient to provide a complete path for the formation of all observed products. 5. All of the intermediates produced by the elementary reactions must be consumed by other elementary reactions so that there will be no net production of intermediate species. 6. The majority of known elementary steps are bimolecular, the remainder being unimolecular or termolecular. The ammonia synthesis reaction is known to occur by a number of steps rather than as N2 + 3H2 → 2NH3. 7. A postulated mechanism for a reaction in the forward direction must also hold true for the reverse reaction. Three corollaries of this guideline should be borne in mind when postulating a reaction mechanism. First, the rate-limiting step for the reverse
Reaction Mechanisms and Rate Expressions
8.
9.
10. 11.
12.
13.
14.
33
reaction must be the same as that for the forward reaction. Second, the reverse reaction cannot have a molecularity greater than three, just as the forward reaction is so limited. As a consequence, the ammonia decomposition reaction 2NH3 → N2 + 3H2 cannot occur as a simple bimolecular process. Third, if the reaction rate expression for the forward reaction consists of two or more independent terms corresponding to parallel reaction paths, there will be the same number of independent terms in the rate expression for the reverse reaction. At equilibrium, both the total rate of the forward reaction is equal to the total rate of the reverse reaction, and the forward rate of each path is equal to the reverse rate of that particular path. Transitory intermediates involving highly reactive species do not react preferentially with one another to the exclusion of their reaction with stable species. When the overall order of a reaction is greater than three, the mechanism probably has one or more equilibria and intermediates prior to the rate-determining step. Inverse orders arise from rapid equilibria prior to the ratedetermining step. Whenever a rate law contains non-integers orders, there are intermediates present in the reaction sequence. When a fractional order is observed in an empirical rate expression for a homogeneous reaction, it is often an indication that an important part of the mechanism is the splitting of a molecule into free radicals or ions. If the magnitude of the stoichiometric coefficient of a reactant exceeds the order of the reaction with respect to that species, there are one or more intermediates and reactions after the ratedetermining step. Before applying this rule, the stoichiometric equation must be formulated for the reaction such that all coefficients are integers. If the order of a reaction with respect to one or more species increases as the concentration of those species increases, it is an indication that the reaction may be proceeding by two or more parallel paths. If there is a decrease in the order of a reaction with respect to a particular substance as the concentration of that species increases, the dominant form of that species in solution may be undergoing a change caused by the change in concentration.
Modeling of Chemical Kinetics and Reactor Design
A decrease in reaction order with respect to hydrogen ion concentration with increasing acidity has frequently been observed for reactions involving weak acids.
TESTING KINETIC MODELS Testing kinetic models involves the following procedures: 1. Propose possible mechanisms involving elementary steps. 2. Assume that the rate equations for each elementary step can be written by inspection of the stoichiometric equation: A + B* → AB*
(1-140)
or
(− rA ) = (− rB )* = kC A C*B
(1-141)
3. Assume that after a short initial period that the rates of concentration change of all active centers are zero. For example:
r k
A + B* 1 → AB*
(1-142)
k
2 AB* + A → A 2 + B*
(1-143)
r
34
(− r ) = k C B*
1
(+ r ) = k C B*
2
A C B*
(1-144)
A C B*
(1-145)
The net rate of disappearance is
(− r )
B* net
=−
dC B = k1C A C B − k 2 C A C AB* dt
(1-146)
From the above assumption, (–rB*)net = 0, steady state approximation. This assumption derives rate equations from which terms involving the concentrations of active centers can be eliminated.
Reaction Mechanisms and Rate Expressions
35
4. If component i takes place in more than one elementary step, then
(± ri ) =
∑( )
± ri All elementary steps
(1-147)
For example, at 480°C the gaseous decomposition of acetaldehyde has an order with respect to concentration of 3/2. The main reaction is CH 3CHO = CH 4 + CO A possible reaction mechanism is: Initiation k
1. CH 3CHO 1 → CH*3 + CHO* Propagation
r
2.
k
2 CH*3 + CH 3CHO → CH 4 + CH 3CO* 3 CH 3CO∗ → CH∗3 + CO
k
3.
r Termination k
4 → C2H6 4. CH*3 + CH*3
It is assumed that for each initiation there are many propagation cycles before termination. The main reaction is therefore given by the addition of the propagation steps alone, which gives the correct stoichiometric equation. A small amount of ethane, C2H6, is expected due to the termination reaction. The rate expressions are:
(+ r
)
CH 3 CO * net
(
+ rCH *
)
3 net
=
=
dC CH
dt
dC CH *
3
dt
3 CO
*
= k 2 C CH * C CH 3CHO − k 3C CH 3
= k1C CH 3CHO + k 3 C CH
3 CO
*
(1-148)
*
2 − k 2 C CH * C CH 3CHO − 2 k 4 C CH * 3
3 CO
3
(1-149)
36
Modeling of Chemical Kinetics and Reactor Design
Using the steady state approximation,
(+ r
(
)
= 0 and + rCH *
CH 3 CO * net
)
3 net
=0
The overall rate equation is:
(− r
)
CH 3 CHO net
=−
dC CH 3CHO dt
(1-150)
= k1C CH 3CHO + k 2 C CH * C CH 3CHO 3
2 From Equations 1-148 and 1-149, 2 k 4 C CH * = k1 C CH 3 CHO and 3
C CH *
3
k = 1 C CH 3CHO 2k 4
0.5
(1-151)
Substituting Equation 1-151 into Equation 1-150 gives
(− r
CH 3 CHO
)=–
dC CH 3CHO dt
k = k1C CH 3CHO + k 2 1 • C CH 3CHO 2k 4 k If k 2 1 C CH 3CHO 2k 4
(− r
CH 3 CHO
)=−
(1-152)
0.5
C CH 3CHO
0.5
>> k1C CH 3CHO, then Equation 1-152 becomes
dC CH 3CHO dt
and −
dC CH 3CHO dt
=
dC CH 4 dt
k2 k = 2 1 2k 4
0.5
C 3CH2 3CHO
(1-153)
Reaction Mechanisms and Rate Expressions
37
This agrees with experimental results. The activation energy that is expected according to a relevant chain reaction mechanism can be determined if each elementary rate constant is expressed with a temperature dependence according to the Arrhenius equation, −E K i = A i exp i RT
(1-154)
Substituting Equation 1-154 into the predicted rate law allows the temperature dependence of the overall reaction to be predicted. In the decomposition of acetaldehyde, it follows that
K obs = A obs
k −E exp a = k 2 1 RT 2k 4
0.5
− E A exp( − E1 RT ) = A 2 exp 2 1 RT 2 A 4 exp( − E 4 RT )
(1-155)
0.5
Separating the variables gives Ea = E2 +
A 1 E1 − E 4 ) and A obs = A 2 1 ( 2 2A 4
0.5
(1-156)
The activation energy for an overall chain reaction can be smaller than E1, the activation energy for the initiation step.
CHAIN LENGTH The efficiency of a chain reaction depends on the number of recycles of the active center for each initiation. The chain length can be defined as: Chain length =
the rate of the overall chain reaction the rate of the initiation reaction
38
Modeling of Chemical Kinetics and Reactor Design
For example, for the decomposition of acetaldehyde: 0.5
k k 2 1 C 3CH2 3CHO 2k 4 Chain length = k1C CH 3CHO k 22 = 2 k1k 4
(1-157)
0.5 0.5 C CH 3 CHO
In this case, the chain length increases with the reactant concentration. Example 1-1
The Hydrogenation of ethylene can be written as C2H4 + H2 = C2H6. It is suggested that the reaction sequence is: Initiation k
(1-158)
k
(1-159)
k
(1-160)
C 2 H 4 + H 2 1 → C 2 H*5 + H*
Closed sequence 2 H* + C 2 H 4 → C 2 H*5
C 2 H*5 + H 2 3 → C 2 H 6 + H* Termination k
4 C 2 H*5 + H* → C2H6
(1-161)
Derive a rate expression for the overall reaction listing any assumptions made. Solution The overall rate of reaction of C2H*5 is
Reaction Mechanisms and Rate Expressions
(+ r ) C 2 H *5
= k1C C 2 H 4 C H 2 + k 2 C C 2 H 4 C H * − k 3C C
net
− k 4CC
* 2H5
* 2H5
39
CH2 (1-162)
CH*
The overall rate of reaction of CH* is
(+ r )
H ∗ net
= k1C C 2 H 4 C H 2 + k 3C C − k 4CC
* 2H5
* 2H5
C H 2 − k 2CC 2 H 4 C H∗
(1-163)
CH*
The overall rate of reaction of C H 2 is
(− r )
H 2 net
= k1C C 2 H 4 C H 2 + k 3C C
* 2H5
CH2
(1-164)
Assuming that ( +rC 2 H *5 ) net and ( +rH * ) net are zero, equating Equations 1-162 and 1-163 gives: k1C C 2 H 4 C H 2 + k 2 C C 2 H 4 C H * − k 3C C
= k1C C 2 H 4 C H 2 + k 3C C
* 2H5
* 2H5
C H 2 − k 4CC
* 2H5
C H 2 − k 2CC 2 H 4 C H* − k 4CC
CH*
(1-165) * 2H5
CH*
Therefore,
2 k 2 C C 2 H 4 C H * = 2 k 3C C k 2CC 2 H 4 k 3C H 2
=
CC
* 2H5
CH2
(1-166)
* 2H5
(1-167)
CH*
From Equation 1-164
(− r )
H 2 net
= k1C C 2 H 4 C H 2 + k 3C C
* 2H5
CH2
Substituting Equation 1-167 into Equation 1-164 gives
40
Modeling of Chemical Kinetics and Reactor Design
(− r )
H 2 net
= k1C C 2 H 4 C H 2 +
k 2 CC 2 H 4 • • C H * k 3C H 2 k3 CH2
(1-168)
= k1C C 2 H 4 C H 2 + k 2 C C 2 H 4 C H * The overall rate of reaction of C C 2 H 4 is
(− r
)
C 2 H 4 net
CH* =
= k1C C 2 H 4 C H 2 + k 2 C C 2 H 4 C H *
(− r
)
C 2 H 4 net
(1-169)
− k1C C 2 H 4 C H 2
(1-170)
k 2CC 2 H 4
Substituting Equation 1-170 into Equation 1-168 yields
(− r )
H 2 net
= k1C C 2 H 4 C H 2
(
(
= k1C C 2 H 4 C H 2 + − rC 2 H 4
(− r )
= − rC 2 H 4
(− r )
= − rC 2 H 4
H 2 net
H 2 net
(
)
(
)
)
− rC H − k1C C 2 H 4 C H 2 2 4 net + k 2CC 2 H 4 k 2CC 2 H 4
)
net
− k1C C 2 H 4 C H 2
(1-171)
net
net
= k1C C 2 H 4 C H 2 + k 2 C C 2 H 4 C H *
(1-172)
but
CH* =
k 3 C C 2 H *5 C H 2 • k2 CC 2 H 4
Since ( +rC
)
* net 2H5
and ( +rH * ) net are zero
k1C C 2 H 4 C H 2 + k 2 C C 2 H 4 C H * − k 3C C
* 2H5
C H 2 − k 4CC
* 2H5
CH* = 0
(1-173)
Reaction Mechanisms and Rate Expressions
k1C C 2 H 4 C H 2 − k 2 C C 2 H 4 C H * + k 3C C
* 2H5
CH 2 − k 4CC
* 2H5
41
C H * = 0 (1-174)
Adding Equations 1-173 and 1-174 gives 2 k1C C 2 H 4 C H 2 − 2 k 4 C C
* 2H5
CH* = 0
(1-175)
Subtracting Equations 1-173 from Equation 1-174 yields
2 k 2 C C 2 H 4 C H * − 2 k 3C C k1C C 2 H 4 C H 2 = k 4 C C
* 2H5
CH2 = 0
(1-176)
* 2H5
CH*
(1-177)
* 2H5
CH2
(1-178)
and k 2 C C 2 H 4 C H * = k 3C C
From Equation 1-177 CC
* 2H5
=
k1C C 2 H 4 C H 2
(1-179)
k 4CH*
Substituting Equation 1-179 into Equation 1-178 gives k 2CC 2 H 4 C H* = k 3 • C H 2 • Therefore,
C 2H * =
k 3 k1 2 • CH2 k2 k4
where
K=
k 3 k1 • k2 k4
k1C C 2 H 4 C H 2 k 4CH*
42
Modeling of Chemical Kinetics and Reactor Design
Hence,
C H * = K 0.5C H 2
(1-180)
Substituting Equation 1-160 into Equation 1-168 gives
(− r )
H 2 net
= k1C C 2 H 4 C H 2 + k 2 C C 2 H 4 K 0.5C H 2
{
= C C 2 H 4 C H 2 k1 + k 2 K 0.5
}
(1-181)
Example 1-2
The overall reaction N2 + O2 → 2NO involves the elementary steps: k
O* + N 2 1 → NO + N * k
2 N * + O 2 → NO + O*
Write down equations for (–rO*)net and (–rN*)net. Assuming these rates are equal to zero and CO* + CN* = CT, a constant, derive an expression for (+rNO) net in terms of C T, C N 2, and C O 2. Solution The net rates of disappearance of the free radicals (–rO*)net and (–rN*)net are:
(− r )
O * net
= k1C O* C N − k 2 C N * C O 2
(1-182)
= k 2 C N * C O 2 − k1C O* C N 2
(1-183)
2
and
(− r )
N * net
Assuming that (–rO*)net and (–rN*)net are zero, then k1C O* C N 2 = k 2 C N * C O 2
(1-184)
Reaction Mechanisms and Rate Expressions
43
and CO* + C N * = C T
(1-185)
Therefore,
CO* = C T − C N *
(1-186)
Substituting Equation 1-186 into Equation 1-184 gives
(
)
k1C N 2 C T − C N * = k 2 C N * C O 2 k1C N 2 C T − k1C N 2 C N * = k 2 C N * C O 2 Therefore, CN* =
k1C N 2 C T
(1-187)
k1C N 2 + k 2 C O 2
The net rate of formation of nitric oxide is:
(+ rNO )net
= k1C O* C N 2 + k 2 C N * C O 2
(
= k1C N 2 C T − C N *
) +k C 2
(1-188)
N*
CO 2
k1C N C T k1C N 2 C T 2 = k1C N 2 C T − + k 2CO 2 k C k C k C + + 1 N2 2 O2 1 N 2 k 2 C O 2 k1C N 2 C T = k1C T C N 2 + k 2 C O 2 − k1C N 2 k1C N 2 + k 2 C O 2
(
=
2 k1k 2 C T C O 2 C N 2 k1C N 2 + k 2 C O 2
)
(1-189)
44
Modeling of Chemical Kinetics and Reactor Design
Example 1-3
The Thermal decomposition of ethane to ethylene, methane, butane, and hydrogen can be expressed by the following mechanism. k
C 2 H 6 1 → 2CH*3
(1-190)
k
2 CH*3 + C 2 H 6 → CH 4 + C 2 H*5
(1-191)
k
3 C 2 H*5 → C 2 H 4 + H*
(1-192)
k
4 H* + C 2 H 6 → H 2 + C 2 H*5
(1-193)
k
5 2C 2 H*5 → C 4 H10
(1-194)
Derive a rate law for the formation of ethylene C2H 4 assuming k 3 << k 5 . The free radicals are CH*3, and C2H*5. Solution Applying the steady state equations for the free radicals H*, CH*3, and C 2H *5, the rate of formation of ethylene C2 H 4 for a constant volume batch reactor is:
(+ r
C2H 4
)=
dC C 2 H 4 dt
= k 3C C
(1-195)
* 2H5
The rate of formation of the free radicals are:
(+ r ) =
dC CH *
CH *3
(+ r ) = C 2 H *5
3
dt dC C
= k1C C 2 H 6 − k 2 C CH * C C 2 H 6 = 0
(1-196)
3
* 2H5
dt
(1-197)
= k 2 C CH * C C 2 H 6 + 3
k 4 C H * C C 2 H 6 − k 5C C2 H * 2 5
=0
Reaction Mechanisms and Rate Expressions
(+ r ) = H*
dC H * dt
= k 3C C
* 2H5
− k 4C H* CC 2 H 6 = 0
From Equation 1-198 k 3C C
* 2H5
(1-198)
− k 4 C H * C C 2 H 6 = 0 . Therefore,
k 3 C C 2 H *5 • k 4 CC 2 H 6
CH* =
45
(1-199)
From Equation 1-196, k1C C 2 H 6 − k 2 C CH * C C 2 H 6 = 0. Therefore, 3
C CH * = 3
k1 k2
(1-200)
From Equation 1-197, k 2 C CH * C C 2 H 6 + k 4 C H * C C 2 H 6 − k 5C C2 H * = 0 . 3 2 5 Therefore, k 5C C2
* 2H5
= k 2 C CH * C C 2 H 6 + k 4 C H * C C 2 H 6 3
(1-201)
Substituting Equations 1-199 and 1-200 into Equation 1-201 gives
k 5C C2
* 2H5
= k 2 • CC 2 H 6 •
k CC H* k1 + k 4CC 2 H 6 • 3 • 2 5 k2 k 4 CC 2 H 6 (1-202)
k 5C C2
* 2H5
= k1C C 2 H 6 + k 3C C
* 2H5
Assuming k 3 << k 5 , therefore,
CC
* 2H5
k = 1 • CC 2 H 6 k5
0.5
(1-203)
Substituting Equation 1-203 into Equation 1-195 gives
(
k + rC 2 H 4 = k 3 1 C C 2 H 6 k5
)
0.5
(1-204)
46
Modeling of Chemical Kinetics and Reactor Design
Example 1-4
Houser and Lee* studied the pyrolysis of ethly nitrate using a stirred flow reactor. They proposed the following mechanism for the reaction: Initiation k
(1-205)
2 C 2 H 5O* → CH*3 + CH 2 O
(1-206)
C 2 H 5ONO 2 1 → C 2 H 5O* + NO 2 Propagation k
k
CH*3 + C 2 H 5ONO 2 3 → CH 3 NO 2 + C 2 H 5O*
(1-207)
Termination k
4 2C 2 H 5O* → CH 3CHO + C 2 H 5OH
(1-208)
The rate of reaction, mols/(ksec)(m3), was measured in a stirred tank reactor in terms of concentration mols/m3. The results are shown in Table 1-2. Find a rate equation consistent with the proposed mechanism and verify it against the data. Assume that the initiation and termination steps are relatively slow. Table 1-2 Ethyl nitrate concentration 0.0975 0.0759 0.0713 0.2714 0.2346
*
J. Phys. Chem., 71, 3422, 1967.
mols m3
Rate
mols (ksec)m3 13.4 12.2 12.1 23.0 20.9
Reaction Mechanisms and Rate Expressions
47
Solution The free radicals are C2 H 5O * and CH *3. The net rate of disappearance of C2H5ONO2 is:
(− r
C 2 H 5 ONO 2
)
net
= k1C C 2 H 5ONO 2 + k 3C CH * C C 2 H 5ONO 2
(1-209)
3
The net rates of disappearance of the free radicals, C2H5O* and CH*3 are:
(− r
)
C 2 H 5O*
net
= k 2CC
2 H 5O
*
+ k 4 C C2
2 H 5O
*
(1-210)
− k1C C 2 H 5ONO 2 − k 3C CH * C C 2 H 5ONO 2 = 0 3
(− r )
= k 3C CH * C C 2 H 5ONO 2 − k 2 C C
CH *3 net
3
2 H 5O
*
=0
(1-211)
From Equation 1-210 k 2CC
2 H 5O
*
+ k 4 C C2
2 H 5O
*
− k1C C 2 H 5ONO 2 − k 3C CH * C C 2 H 5ONO 2 = 0 (1-212) 3
From Equation 1-211
k 3C CH * C C 2 H 5ONO 2 − k 2 C C
2 H 5O
*
k 3C CH * C C 2 H 5ONO 2 = k 2 C C
2 H 5O
*
3
3
=0
(1-213) (1-214)
Substituting equation 1-214 into Equation 1-212 gives k 2CC
2 H 5O
*
+ k 4 C C2
2 H 5O
*
− k1C C 2 H 5ONO 2 − k 2 C C
2 H 5O
*
=0
48
Modeling of Chemical Kinetics and Reactor Design
and
CC
2 H 5O
*
k = 1 • C C 2 H 5ONO 2 k4
0.5
(1-215)
From Equation 1-214
C CH * = 3
k 2 CC 2 H 5O* • k 3 C C 2 H 5ONO 2
k1 k 1 = 2• • C C 2 H 5ONO 2 k 3 C C 2 H 5ONO 2 k 4 k k 1 = 2 1• k 3 k 4 C C 2 H 5ONO 2
0.5
0.5
(1-216)
For ethyl nitrate, Equation 1-209 becomes
(− r
C 2 H 5 ONO 2
)
net
0.5 k 2 k1 1 = k1 + k 3 • • C C H ONO 2 k 3 k 4 C C 2 H 5ONO 2 2 5
0.5 k1 1 = k1 + k 2 • k4 C C 2 H 5ONO 2
(
)
0.5 C C 2 H 5 ONO 2
where k1 and k4 are small in comparison with k2, therefore,
(1-217)
Reaction Mechanisms and Rate Expressions
(− r
C 2 H 5 ONO 2
)
net
= kC C0.25H 5ONO 2
49
(1-218)
Equation 1-218 can be expressed in the form Y = AXB. Using natural logarithm, Equation Y = AXB gives
ln(Y ) = ln A + B • ln( X )
(1-219)
If we perform a regression analysis on Equation 1-219, the slope gives the order of the reaction and the rate constant is determined by the intercept. Appendix A illustrates a developed computer program that performs the regression analysis of equations for any given set of data. The results of the linearized regression analysis from the computer program give slope B as 0.486, and intercept A as 42.7. Table 1-3 shows the results of the estimated reaction rate of ethyl nitrate with a correlation coefficient = 0.9979. Figure 1-6 shows plots of the regression model and the experimental results. Equation 1-218 can now be expressed as:
(− r
C 2 H 5 ONO 2
) = 42.7 C
0.486 C 2 H 5 ONO 2
This confirms the half order of the rate expression.
Table 1-3 Ethyl nitrate concentration
0.0975 0.0759 0.0713 0.2714 0.2346
mols m3
Actual
mols (ksec)m3 Estimated
13.4 12.2 12.1 23.0 20.9
13.8 12.2 11.8 22.7 21.1
Reaction rate
50
Modeling of Chemical Kinetics and Reactor Design
Figure 1-6. Reaction rate of ethyl nitrate as a function of concentration.
Example 1-5
Determine the Michaelis-Menten Parameters V max and K m for the reaction: urea + urease
k1
[ [urea • urease]* + H 2O k 2
[urea • urease]* + H 2O
k
3 → 2 NH 3 + CO 2 + urease
The rate of reaction is given as a function of urea concentration in Table 1-4. Solution Using Equation 1-220 VO =
Vmax • C urea C urea + K m
and rearranging gives
(1-220)
Reaction Mechanisms and Rate Expressions
51
Table 1-4
kmol Curea , m3
kmol Vurea , 3 m • s
0.6 0.4 0.2 0.02 0.01 0.005 0.002 0.001
1.80 1.45 1.07 0.54 0.36 0.19 0.085 0.06
K 1 1 1 = + m • VO Vmax Vmax C urea
(1-221)
A plot of the reciprocal reaction rate versus the reciprocal urea concentration should give a straight line with an intercept 1/Vmax and the slope Km/Vmax. Figure 1-7 gives a plot of 1/VO versus 1/Curea from the developed linear regression method. The results of the computer program give the intercept 1/Vmax = 1.1741 and, therefore, the maximum rate is Vmax = 0.852(kmol/m3.s). The slope Km/Vmax = 0.0167 and Km = 0.0142 (kmol/m3). Substituting Km and Vmax in Equation 1-220 gives VO =
0.852 C urea kmol , 0.0142 + C urea m 3 • s
Example 1-6 Pyrolysis of Ethane C2H 6 (See Example 1-3)
The decomposition of ethane has been extensively studied and several mechanisms have been postulated. The main products of the reaction are ethylene, C2H4, and hydrogen, H2. However, there are small amounts of methane, CH4, butane, C4H10, and other products.
52
Modeling of Chemical Kinetics and Reactor Design
Figure 1-7. Lineweaver-Burk plot of (1/Curea) versus (1/Vo).
The overall reaction is: C2H6 = C2H 4 + H2
The reaction is first order in the temperature range of 550–640°C and at pressure in excess of 50 mm Hg. The rate law is given by
(− r
C2H6
)=−
dC C 2 H 6 dt
= kC C 2 H 6
(1) Develop a mechanism to account for the first-order rate law for the case where only methane is formed as a byproduct. Assume that the chain length is large. Mechanism Initiation k
1. C 2 H 6 1 → CH*3 + CH*3 k
2 → CH 4 + C 2 H*5 2. CH*3 + C 2 H 6
(1-222) (1-223)
Reaction Mechanisms and Rate Expressions
53
Propagation k
3. C 2 H*5 3 → C 2 H 4 + H*
(1-224)
k
4 → C 2 H*5 + H 2 4. H* + C 2 H 6
(1-225)
Termination k
5 → C2H6 5. H* + C 2 H*5
(1-226)
Applying the rate expressions to Equations 1-222, 1-223, 1-224, 1-225 and 1-226, and using the steady state approximation for CH*3, C2H*5, and H*, for a constant volume batch reactor yields:
(− r
)
C 2 H 6 net
=−
dC C 2 H 6 dt
= k1C C 2 H 6 + k 2 C CH * C C 2 H 6 3
+ k 4 C H * C C 2 H 6 − k 5C H * C C
(
− rCH *
(
− rC 2 H 5
)
3 net
)
=−
net
dC CH *
3
dt
=−
(1-227) * 2H5
= k 2 C CH * C C 2 H 6 − 2 k1C C 2 H 6 = 0 3
dC C
* 2H5
dt
= k 3C C
* 2H5
+ k 5C C
* 2H5
(1-228)
CH*
(1-229)
− k 2 C CH * C C 2 H 6 − k 4 C H * C C 2 H 6 = 0 3
(− r )
H * net
=−
dC H * dt
(1-230)
= k 4 C H * C C 2 H 6 + k 5C H * C C
* 2H5
− k 3C C
* 2H5
=0
Rearranging Equations 1-228, 1-229, and 1-230 gives dC CH *
3
dt
= 2 k1C C 2 H 6 − k 2 C CH * C C 2 H 6 = 0 3
(1-231)
54
Modeling of Chemical Kinetics and Reactor Design
dC C
* 2H5
= k 2 C CH * C C 2 H 6 + k 4 C H * C C 2 H 6
dt
3
− k 3C C dC H *
= k 3C C
dt
* 2H5
− k 5C C
* 2H5
* 2H5
(1-232)
CH* = 0
− k 4 C H * C C 2 H 6 − k 5C H * C C
* 2H5
=0
(1-233)
Adding Equations 1-231, 1-232, and 1-233 gives
k1C C 2 H 6 = k 5C H * C C
(1-234)
* 2H5
This shows that the rate of initiation equals the rate of termination. Thus, CH* =
k1C C 2 H 6 k 5C C
(1-235)
* 2H5
Substituting Equation 1-235 into Equation 1-233 gives
k 3C C
* 2H5
k 3 k 5C C2
− k 4CC 2 H 6 •
* 2H5
k1C C 2 H 6 k 5C C
* 2H5
− k 5C C
* 2H5
•
− k1k 4 C C2 2 H 6 − k1C C 2 H 6 = 0
k1C C 2 H 6 k 5C C
=0
* 2H5
(1-236)
The rate of production of ethylene C2H4 is:
(+ r
C2H 4
)=
dC C 2 H 4 dt
= k 3C C
* 2H5
(1-237)
Introducing the chain length, Chain length =
k 3C C
* 2H5
k1C C 2 H 6
(1-238)
Reaction Mechanisms and Rate Expressions
55
If the chain length is large, it follows that
k 3C C
* 2H5
>> k1C C 2 H 6
(1-239)
and Equation 1-236 becomes k 3 k 5C C2
* 2H5
− k1k 4 C C2 2 H 6 = 0
(1-240)
Thus,
CC
* 2H5
k k = 1 4 k 3k 5
0.5
CC 2 H 6
(1-241)
Substituting Equation 1-241 into Equation 1-237 gives
(+ r
C2H 4
)=
k k k = 1 3 4 k5
dC C 2 H 4 dt
k k = k3 1 4 k 3k 5
0.5
CC 2 H 6
0.5
CC 2 H 6
(1-242)
The rate of decrease in ethane C2H6 is:
(− r −
C2H6
)= −
dC C 2 H 6 dt
dC C 2 H 6 dt
= k1C C 2 H 6 + k 2 C CH * C C 2 H 6 + k 4 C H * C C 2 H 6 − k 5C H * C C 3
* 2H5
which together with Equation 1-232 yields
(− r
C2H6
) =−
dC C 2 H 6 dt
= k1C C 2 H 6 + k 3C C
* 2H5
From Equations 1-237, 1-239, and 1-242, it follows that
(1-243)
56
Modeling of Chemical Kinetics and Reactor Design
(− r
C2H6
−
) = (+ r
dC C 2 H 6 dt
C2H 4
=
)
dC C 2 H 4
= k 3C C
dt
* 2H5
k k k = 1 3 4 k5
= K 0.5C C 2 H 6
0.5
CC 2 H 6
(1-244)
This mechanism explains the first order dependence of the reaction. (2) Develop now another mechanism accounting for the formation of both methane and butane. If other possible termination steps are considered, then it can be inferred that recombination or disproportionation of ethyl radicals, C C H * is more likely than recombination of C * and C * . Step 5 H C2H5 2 5 should then be replaced by 5a.
C 2 H*5 + C 2 H*5 → C 4 H10
and 5b.
C 2 H*5 + C 2 H*5 → C 2 H 4 + C 2 H 6
This also accounts for the production of the small amount of butane. If the reaction mechanism were steps 1, 2, 3, 4, 5a, and 5b, then applying the steady state approximations would give the overall order of reaction as 1/2. Assuming that the initiation reaction is second order, then step 1 becomes 1a.
C 2 H 6 + C 2 H 6 → 2 CH*3 + C 2 H 6
The reaction mechanism now becomes Initiation 1a. 2.
k
1a C2H6 + C2H6 → 2CH*3 + C 2 H 6
k
2 CH*3 + C 2 H 6 → CH 4 + C 2 H*5
(1-245) (1-246)
Reaction Mechanisms and Rate Expressions
57
Propagation k
3.
C 2 H*5 3 → C 2 H 4 + H*
4.
4 H* + C 2 H*6 → C 2 H*5 + H 2
(1-247)
k
(1-248)
Termination k
5a.
5a C 2 H*5 + C 2 H*5 → C 4 H10
5b.
5b C 2 H*5 + C 2 H*5 → C2H 4 + C2H6
(1-249)
k
(1-250)
Applying the steady state approximation gives
(
)
+ rCH ∗ = 3
dC CH *
(
3
∗ 2H5
dC C
3
dt
= 2 k1a C C2 2 H 6 − k 2 C CH * C C 2 H 6 = 0
3
dt + rC
dC CH ∗
)
* 2H5
dt
=
dC C
(1-251)
∗ 2H5
dt
= k 2 C CH * C C 2 H 6 − k 3C C 3
−2( k 5a + k 5b )C C2
* 2H5
* 2H5
+ k 4C H* CC 2 H 6
=0
(1-252)
and
(+ r ) = H∗
dC H * dt
dC H ∗ dt
= k 3C C
* 2H5
− k 4C H* CC 2 H 6 = 0
(1-253)
58
Modeling of Chemical Kinetics and Reactor Design
Adding Equations 1-251, 1-252, and 1-253 gives
CC
* 2H5
k1a = k 5a + k 5 b
0.5
CC 2 H 6
(1-254)
Therefore, −
dC C 2 H 6 dt
dC C 2 H 4 dt
(
)
= + rC 2 H 4 =
= k 3C C
* 2H5
dC C 2 H 4 dt
k1a = k3 k 5a + k 5 b
0.5
CC 2 H 6
(1-255)
This mechanism once again predicts the first order dependence of the reaction.
REFERENCES 1. Bailey, J. E. and Ollis, D. F. Biochemical Engineering Fundamentals, 2nd ed., McGraw-Hill Chemical Engineering Series, 1988. 2. Lin, K. H. “Part 1, Applied Kinetics,” Industrial and Engineering Chemistry, Vol. 60, No. 5, pp. 61–82, May 1968. 3. Bodenstein, M. and Lind, S. C. Physik. Chem, 57, 168, 1907. 4. Bodenstein, M. Z. Elektrochem, 85, 329, 1913. 5. Nernst, W. Z. Elektrochem, 24, 335, 1918. 6. Taylor, H. S. Trans. Faraday Soc., 21, 5601, 1926. 7. Rice, F. O. and Herzfeld, K. F. J. Am. Chem. Soc., 56, 284, 1934. 8. Yang, K. H. and Hougen, O. A. “Determination of Mechanism of Catalyzed Gaseous Reactions,” Chemical Engineering Process, p. 146, March 1950. 9. Hougen, O. A. and Watson, K. M. Ind. Eng. Chem., 35, 529, 1943.
Thermodynamics of Chemical Reactions
59
CHAPTER TWO
Thermodynamics of Chemical Reations INTRODUCTION The two main principles involved in establishing conditions for performing a reaction are chemical kinetics and thermodynamics. Chemical kinetics is the study of rate and mechanism by which one chemical species is converted to another. The rate is the mass in moles of a product produced or reactant consumed per unit time. The mechanism is the sequence of individual chemical reaction whose overall result yields the observed reaction. Thermodynamics is a fundamental of engineering having many applications to chemical reactor design. Some chemical reactions are reversible and, no matter how fast a reaction takes place, it cannot proceed beyond the point of chemical equilibrium in the reaction mixture at the specified temperature and pressure. Thus, for any given conditions, the principle of chemical equilibrium expressed as the equilibrium constant, K, determines how far the reaction can proceed if adequate time is allowed for equilibrium to be attained. Alternatively, the principle of chemical kinetics determines at what rate the reaction will proceed towards attaining the maximum. If the equilibrium constant K is very large, for all practical purposes the reaction is irreversible. In the case where a reaction is irreversible, it is unnecessary to calculate the equilibrium constant and check the position of equilibrium when high conversions are needed. Both the principles of chemical reaction kinetics and thermodynamic equilibrium are considered in choosing process conditions. Any complete rate equation for a reversible reaction involves the equilibrium constant, but quite often, complete rate equations are not readily available to the engineer. Thus, the engineer first must determine the temperature range in which the chemical reaction will proceed at a 59
60
Modeling of Chemical Kinetics and Reactor Design
reasonable rate (possibly in the presence of any catalyst that may have been developed for the reactions). Next, the values of the equilibrium constant, K, in this temperature range must be computed using the principles of thermodynamics. The equilibrium constant of the reaction depends only on the temperature and is used to determine the limit to which the reaction can proceed under the conditions of temperatures, pressure, and reactant compositions that appear most suitable.
CHEMICAL EQUILIBRIUM Consider a single homogeneous phase of one component of unchanging composition. If it undergoes an isothermal reversible change and does work, then from the first law of thermodynamics: q = dU + pdV or dU = q – pdV
(2-1)
From the second law of thermodynamics:
dS =
q , reversible change T
q = TdS
(2-2)
Combining the first and second laws (Equations 2-1 and 2-2) gives: dU = TdS – pdV
(2-3)
Now consider a homogeneous phase containing different substances or components. Its phase contains: • n1 moles of component 1 • ni moles of component i • nk moles of component k For a constant composition, it is known that dU = TdS – pdV. For a variable composition, U = U(S, V, n1, . . . ni . . . nk) Performing a partial differentiation on Equation 2-4 yields
(2-4)
Thermodynamics of Chemical Reactions
dU =
∂U ∂U dS + dV + ∂V S, n ∂S V, n i i
61
i=k
∂U i S, V, n i =1
∑ ∂n
dn i
(2-5)
j, i≠ j
If the number of moles are held constant, then from Equation 2-3 ∂U ∂U = T and = −p ∂S V, n ∂V S, n i i
(2-6)
The chemical potential µi is defined by ∂U µi ≡ ∂n i S, V, n
(2-7) j
Equation 2-5 thus becomes dU = TdS − pdV + ∑ µ i dn i i =1
(2-8)
The Gibbs function is expressed as: G = U + pV – TS
(2-9)
Differentiating Equation 2-9 gives dG = dU + pdV + Vdp – TdS – SdT
(2-10)
Substituting Equation 2-3 into Equation 2-10 yields dG = TdS – pdV + pdV + Vdp – TdS – SdT
(2-11)
dG = Vdp – SdT
(2-12)
Since Equation 2-12 holds for a system of constant composition, it is expressed as G = G(T, P, n1, ni . . . nk) Partial differentiation of Equation 2-13 gives
(2-13)
62
Modeling of Chemical Kinetics and Reactor Design
dG =
∂G ∂G dT + dP + ∂T P, n ∂P T, n i
i
∂G dn i i T, P, n i =1 k
∑ ∂n
(2-14)
j
If the compositions are held constant, then ∂G ∂G = − S, =V ∂T P, n ∂P T, n i i
(2-15)
And again, µi is defined as
∂G µi ≡ ∂n i T, P, n
(2-16) j
Substituting Equations 2-15 and 2-16 into Equation 2-14 gives dG = − SdT + V dP +
i=k
∑ µ i dn i i =1
(2-17)
Other state functions are the enthalpy function: H = U + pV
(2-18)
and the Helmholtz function: A = U – TS
(2-19)
The chemical potential µ can also be expressed in terms of H and A. The complete set of equations are:
dU = T dS − p dV + ∑ µ i dn i dG = V dp − SdT +
∑ µ i dn i
(2-20) (2-21)
dH = T dS + V dp + ∑ µ i dn i
(2-22)
dA = − SdT − p dV + ∑ µ i dn i
(2-23)
Thermodynamics of Chemical Reactions
63
where ∂U ∂U ∂H ∂A µi = = = = ∂n i S, V, n ∂n i T, P, n ∂n i S, P, n ∂n i T, V, n j
j
j
(2-24) j
CRITERIA FOR EQUILIBRIUM For a reversible change, dS = q/T. If we consider a closed system undergoing a reversible change at dT = 0, dP = 0, then the only form of work is pdV. From the first law: dU = q – pdV
(2-1)
From the second law of thermodynamics: dS =
q , is a reversible change T
q = TdS
(2-2)
Combining the first and second laws gives: dU = TdS – pdV
(2-3)
That is dU – TdS + pdV = 0
(2-25)
Defining G = U + PV – TS
(2-9)
Differentiating gives dG = du + pdV + Vdp – TdS – SdT
(2-11)
Restricting this to the case of isothermal and isobaric, dP = 0, dT = 0, then dG = dU + pdV – TdS
(2-26)
64
Modeling of Chemical Kinetics and Reactor Design
Thus, for any small reversible displacement at equilibrium, dG = 0, if dP = 0, dT = 0. Similarly: If dT = 0, dV = 0 then dA = 0 If dP = 0, dS = 0 then dH = 0 If dV = 0, dS = 0 then dU = 0
REACTION EQUILIBRIUM Considering any generalized reversible chemical reaction, such that at dT = 0 and dP = 0: aA + bB
[ cC + dD
(2-27)
If the reaction mixture is large enough that the mole numbers corresponding to the stoichiometric numbers react, then the compositions remain unchanged. If these mole numbers react at equilibrium, then the overall change in Gibbs function is dG = cµC + dµD – aµA – bµB = 0
at equilibrium
(2-28)
Since µA =
∂G A ∂n A
(2-29)
The chemical potential as a function of composition can be expressed as µ = µ oi + RT ln a i
(2-30)
where ai is the activity of i. Introducing Equation 2-30 into the change in the Gibbs statement, and separating the standard state terms on the right side, gives
RT ln
a Cc • a dD = − {cµ Co + dµ oD − aµ oA − bµ oB } a aA • a Bb
− (cµ Co + dµ oD − aµ oA − bµ oB ) a Cc • a dD = exp a aA • a Bb RT
(2-31)
(2-32)
Thermodynamics of Chemical Reactions
− ∑ υ i µ i = exp =K RT
65
(2-33)
The right side is the equilibrium constant, K. The left side contains the fugacities of the reactants in the mixture at the equilibrium composition. For gases, the right side is independent of pressure and composition and is equivalent to ag oA + bg oB − cg Co − dg oD
(2-34)
where goA is the specific Gibbs function of pure A at the standard state conditions, that is g oA = h oA − TsoA
(2-35)
IDEAL GAS MIXTURES For an ideal gas mixture, ai = pi, which is expressed as p Cc • p dD = Kp p aA • p Bb
(2-36)
where p is the partial pressure. This is related to the total pressure as the total pressure, PT, multiplied by the mole fraction of the component in the mixture. That is: pi = y iPT
(2-37)
Substituting Equation 2-37 into Equation 2-36 yields y Cc • y dD ( c + d − a − b ) = Kp PT y aA • y Bb
(2-38)
REAL GASES—IDEAL GASEOUS SOLUTION In many cases, the assumption of ideal gases is not justified and it will be essential to determine fugacities. An example of such reactions
66
Modeling of Chemical Kinetics and Reactor Design
is ammonia synthesis where the operating pressure may be as high as 1,500 atm. The real gas can be expressed as fCc • fDd = Kf fAa • fBb
(2-39)
The fugacity in Equation 2-39 is that of the component in the equilibrium mixture. However, fugacity of only the pure component is usually known. It is also necessary to know something about how the fugacity depends on the composition in order to relate the two, therefore, assumptions about the behavior of the reaction mixture must be made. The most common assumption is that the mixture behaves as an ideal solution. In this case, it is possible to relate the fugacity, f, at equilibrium to the fugacity of the pure component, f′, at the same pressure and temperature by fi = yif′
(2-40)
Equation 2-40 is known as the Lewis Randall rule, where f′ is the fugacity of pure component i at the same temperature and total pressure as the mixture. Substituting Equation 2-40 into Equation 2-39 gives
(f ′ ) • (f ′ ) y Cc • y dD = Kf • A c B d a b yA • yB (fC′ ) • (fD′ ) a
b
(2-41)
where Ky =
y Cc • y dD y aA • y Bb
(2-42)
The f′A, f B′ , fC′ , and fD′ are determined for the pure gas at the pressure of the mixture and depend on the pressure and the temperature. In gaseous mixtures, the quantity Kp as defined by Equation 2-38 is used. For an ideal gas reaction mixture, Kf = Kp. For a non-ideal system, Equation 2-39 can be used to calculate K p from the measured equilibrium compositions Ky using Equation 2-42. The composition
Thermodynamics of Chemical Reactions
67
ratio Kf can then be determined from the equilibrium constant. This step is necessary in determining the equilibrium conversion from free energy data. The steps in the process are: 1. Calculate the standard change of free energy, ∆Go. ∆Go = –RT ln Kf
(2-43)
or ∆Go = –RT ln Kp
(2-44)
where ∆Go is the difference between the free energies of the products and reactants when each is in a given standard state. 2. Determine the equilibrium constant Kf using Equation 2-43. 3. Evaluate Ky from Equation 2-42. 4. Calculate the conversion from Ky. Steps 1 and 2 require thermodynamic data. Figure 2-1 shows the equilibrium constants of some reactions as a function of temperature. The Appendix at the end of this chapter gives a tabulation of the standard change of free energy ∆Go at 298 K.
REAL GASES If φ is the fugacity coefficient, and is defined by φ=
fi p
(2-45)
Then fi = φp
(2-46)
Substituting Equation 2-45 into Equation 2-39 gives
φ Cc • φ dD p Cc • p dD • = Kf φ aA • φ Bb p aA • p Bb
(2-47)
68
Modeling of Chemical Kinetics and Reactor Design
Figure 2-1. Chemical equilibrium constants as a function of temperature. (Source: M. Modell and R. C. Reid, Thermodynamics and its Applications, Prentice-Hall, Inc., Englewood Cliffs, NJ.)
Thermodynamics of Chemical Reactions
69
Thus, fCc • fDd − ∆G o = K = exp f RT fAa • fBb
(2-48)
Replacing fi by φipi gives φ Cc • φ dD p Cc • p dD • = Kf φ aA • φ Bb p aA • p Bb
(2-49)
Since p = yP, Equation 2-49 then becomes
φ Cc • φ dD y Cc • y dD • = K f P (a + b − c − d ) φ aA • φ Bb y aA • y Bb
(2-50)
Fugacities are evaluated at the conditions at which the gases exist in the mixture.
LIQUID STATE Chemical potentials can be expressed as: µi = µ*i + RT ln γixi
(2-51)
µi = µ*i + RT ln ai
(2-52)
or
where xi = mole fraction of component i γi = activity coefficient of component i ai = activity of component i Equation 2-52 gives
a Cc • a dD − ∆µ * = exp = KL RT a aA • a Bb
(2-53)
70
Modeling of Chemical Kinetics and Reactor Design
KL is not independent of pressure because it is a function of the chemical potentials of pure i at the temperature T and pressure P of the mixture or of the infinite dilution state of i.
DETERMINING THE FUGACITY AND FUGACITY COEFFICIENT For any single component fluid at constant temperature and composition, ∂µ i ∂p T, n
= Vi i ,n j
(2-54)
or dµ i = Vdp
(2-55)
where µi is the chemical potential of the pure gas at temperature T and pressure P. The fugacity f of the gas in which µo is a function of the temperature is µi = µoi + RT ln fi
(2-56)
Differentiating Equation 2-56 at constant temperature and composition gives dµi = RTd ln fi
(2-57)
Combining Equations 2-55 and 2-57 gives
[RT d ln fi = Vi dp]T
(2-58)
Subtracting RTd ln pi from both sides of Equation 2-58 gives f RT d ln i = Vi dp − RT d ln p i pi = Vi dp − RT d ln p i − RT d ln y i
(2-59)
Thermodynamics of Chemical Reactions
71
Since the composition is constant, dlny i = 0 and Equation 2-59 becomes f RT RT d ln i = Vi − dp p pi
(2-60)
where Vi is the partial molar volume. For a single gas, Equation 2-60 reduces to give
f RT RT d ln = V − dp p p
(2-61)
where V is the specific volume. If we integrate at constant temperature and constant composition from p = 0 to the particular pressure p = p′, which is required to calculate the fugacity, the following is obtained: f f ln i − ln i = pi p = p′ pi p = 0
p′
V
1
∫ RT − p dp
(2-62)
0
fi/pi = 1 at p = 0, which yields f ln i = p p= p′
p′
V
1
∫ RT − p dp
(2-63)
0
Equation 2-63 gives the fugacity at p′ and T in terms of an integral that is evaluated from experimental data. Equation 2-63 can be expressed in terms of the compressibility factor
Z=
pV RT
(2-64)
and Equation 2-63 now becomes f ln = p′
p′
Z − 1 dp p 0
∫
(2-65)
72
Modeling of Chemical Kinetics and Reactor Design
PARTIAL MOLAR QUANTITIES Considering any extensive property K, the partial molar quantity is defined by
∂K Ki = ∂n i T, P, n
(2-66) j, i ≠ j
where T, P, nj are held constant, then K = K(T, P, n1, n2, . . . ni . . . nk)
(2-67)
Differentiating Equation 2-67 gives
dK =
∂K ∂K dT + dP + ∂T P, n ∂P T, n i
i
∂K dn i i T, P, n i =1
∑ ∂n
(2-68)
j
Once again, integrating as in the Gibbs-Duhem equation, yields K =
∑ n i Ki
(2-69)
i =1
Similarly, U =
∑ n i Ui , i =1
H =
∑ n i Hi i =1
and
G =
∑ n i Gi
(2-70)
i =1
For a pure component U i = u i , H i = h i and G = g i The partial molar Gibbs function is given by ∂G ∂n i T, P, n
j
(2-71)
Thermodynamics of Chemical Reactions
73
This is identical with the definition of µi in terms of Gi, but this is only true for G because only the pressure P and temperature T hold constant for G. Therefore, in general
∂K µ i ≡/ ∂n i T, P, n
(2-72) j
This can be expressed as H i = U i + PVi
(2-73)
and µ i = G i ≡ H i − TSi
(2-74)
From Equation 2-21 dG = − SdT + P dV +
∑ µ i dn i i =1
(2-21)
Also
∂G ∂p T, n
= V
(2-75)
i, n j
Differentiating Equation 2-75 with respect to n gives
∂2G ∂V = ∂n∂p ∂n But
∂G = µi ∂n i
(2-76)
(2-77)
Differentiating Equation 2-77 with respect to P yields ∂µ i ∂2G = ∂P∂n i ∂P
(2-78)
74
Modeling of Chemical Kinetics and Reactor Design
Since the order of differentiating is indifferent, then ∂µ i ∂P T, n
i ,n j
∂V = = Vi ∂n i T, P, n
(2-79)
j
and similarly ∂µ i ∂T P, n
= i ,n j
−∂S = − Si ∂n T, P, n
(2-80)
j
Substituting Equation 2-80 into Equation 2-74 gives ∂µ µ i = H i + T i ∂T P, n
(2-81) i ,n j
Rearranging Equation 2-81 yields µi ∂ T ∂T P, n
=
− Hi T2
(2-82)
i ,n j
EFFECT OF TEMPERATURE ON THE EQUILIBRIUM CONSTANT Generally, − ∑ υ i µ o K = exp RT
(2-83)
or ln K =
− 1 υi µ o ∑ T R
(2-84)
Thermodynamics of Chemical Reactions
75
where υi is the stoichiometric number, that is, a, b, c, d. Differentiating Equation 2-84 with respect to T gives
µo d i T d ln K −1 = υi ∑ dT R dT
(2-85)
but µo d i T − h oi = 2 dT T
(2-86)
Hence,
d ln K −1 = dT RT 2
∑ υi h oi
(2-87)
where hoi is the enthalpy of pure i at temperature T of the mixture for gases at unit fugacity, for liquids pressure P of mixture. If υihoi is replaced by the conventional ∆Ho when the moles represented by stoichiometric numbers react, then d ln K ∆H o = dT RT 2
van’t Hoffs equation
(2-88)
where ∆Ho is a function of temperature, but can be assumed constant over a small temperature range to enable an equilibrium constant at one T to be deduced from that for a T close to it. Integrating Equation 2-88 gives ln
K2 ∆H o = K1 R
1 1 − T2 T1
(2-89)
HEATS OF REACTION If a process involves chemical reactions, heat effects will invariably be present. The amount of heat produced in a chemical reaction
76
Modeling of Chemical Kinetics and Reactor Design
depends on the conditions under which the reaction is carried out. The standard heat of reaction is the enthalpy variation when the reaction is carried out under standard conditions using pure components in their most stable state or allotropic form, at standard pressure (1 atm) and temperature (usually, but not necessarily 298 K). The values for standard heats of reaction may be found in the literature or calculated by thermodynamic methods. The physical state of the reactants and products (e.g. gas, liquid, or solid) must also be specified, if the reaction conditions are such that different states may coexist. For example, H 2 (g) +
1 O 2 (g) → H 2 O (g) 2
∆H 298 = − 241.6 kJ
(2-90)
H 2 (g) +
1 O 2 (g) → H 2 O (l ) 2
∆H 298 = − 285.6 kJ
(2-91)
In process design calculations, it is usually more convenient to express the heat of reaction in terms of the enthalpy per mole of product formed or reactant consumed. Since enthalpy is a state function, standard heats of reaction can be used to estimate the ∆H at different temperatures by making a heat balance over a hypothetical process: ∆H rxnT = ∆H rnxTo + ∆H products − ∆H reactants
(2-92)
where ∆HrxnT = heat of reaction at temperature, T ∆H rnxTo = heat of reaction at a known standard temperature ∆Hreactants = enthalpy change to bring reactants from temperature T to standard temperature ∆Hproducts = enthalpy change to bring products from the standard temperature back to reaction temperature T The specific heats, Cp are usually expressed as a quadratic or a polynomial function of temperature and expressed as: C p i = A i + (Bi •10 −2 • T ) + (C i •10 −5 • T 2 )
(2-93)
C p i = A i + (Bi •10 −2 • T ) + (C i •10 −5 • T 2 ) + (D i •10 −9 • T 3 )
(2-94)
or
Thermodynamics of Chemical Reactions
77
where C p i is in cal/mol K or J/mol K and T is in degrees Kelvin (1 cal = 4.184 J). If stoichiometric quantities of the reactants enter and the products leave at the same temperature as represented by the equation: α1A + α2B → α3C + α4D
(2-95)
Equation 2-95 represents a reaction at a temperature different from the standard state of 25°C (298 K) in stoichiometric quantities. Figure 2-2 shows the information for calculating the heat of reaction.
Figure 2-2. Heats of reaction at temperature other than standard condition.
78
Modeling of Chemical Kinetics and Reactor Design
Assuming a steady state process (∆E = 0), no kinetic (KE) or potential energy (PE) changes and mechanical work done (W) by the system on the surroundings are zero, that is KE, PE, and W = 0, the general energy balance ∆E = E2 – E1 = –∆{(H + KE + PE)m} + Q – W
(2-96)
where
∆E = ( U + KE + PE )t 2 m 2 − ( U + KE + PE )t1 m1
(2-97)
reduces to
{
}
Q = ∆H = ∆H of + ∆(H − H o )
{
products
}
− ∆H of + ∆(H − H o )
(2-98) reactants
or
(
Q = ∆H orxnTref + ∆H products − ∆H reactants
)
(2-99)
Calculating the heat of reaction is a multi-step process. Beginning with the standard heats of formation at 298 K, first calculate the standard heat of reaction, and then calculate ∆H for the actual system temperature and pressure. The heat of reaction at 298 K, ∆H 298 is usually referred to as the standard heat of reaction. This can be readily calculated from the standard heats of formation of the reaction components. The standard heat of reaction is expressed as: ∆H orxnT298 =
(∑ α products • ∆H products ) − (∑ α reactants • ∆H reactants )
(2-100)
The heat of reaction at the system temperature is
∆H rxnT = ∆H orxnT298 + ∆H products − ∆H reactants
(2-101)
Thermodynamics of Chemical Reactions
79
If no phase change occurs, the difference ∆Hproducts – ∆Hreactants can be written as T
∆H products − ∆H reactants =
∫
∆C p dT
(2-102)
298
where Cp is given by ∆C p = ∆a + ( ∆b • T ) + ( ∆c • T 2 ) + ( ∆d • T 3 )
(2-103)
and ∆Cp is in cal/mol K, J/mol K, using T in degrees Kelvin. The constants for the equation are found by
∆a =
∑ α products • a products − ∑ α reactants • a reactants
(2-104)
∆b =
∑ α products • b products − ∑ α reactants • b reactants
(2-105)
∆c =
∑ α products • c products − ∑ α reactants • c reactants
(2-106)
∆d =
∑ α products • d products − ∑ α reactants • d reactants
(2-107)
So that T
∫
298
T
∆C p dT =
∫ {∆a + (∆b • T) + (∆c • T 2 ) + (∆d • T 3 )} dT
(2-108)
298
Integrating Equation 2-108 yields T
∫
298
∆C p dT = ∆a (T − 298) +
∆b 2 (T − 2982 ) 2
∆c ∆d 4 + (T 3 − 2983 ) + (T − 2984 ) 3 4
(2-109)
The heat of reaction at the system temperature is therefore given by
80
Modeling of Chemical Kinetics and Reactor Design
∆H rxnT = ∆H rxnT298 + ∆a (T − 298) + +
∆b 2 (T − 2982 ) 2
∆c 3 (T − 2983 ) + ∆4d (T 4 − 2984 ) 3
(2-110)
ENTHALP, a computer software, was developed to calculate the heat of reaction at the system temperature. To run the program, the user must know the following: • • • •
The standard temperature (298 K) To and the system temperature TF. The reaction stoichiometric coefficients α1, α2, α3, and α4. Heat capacity constants, and a1, a2, a3, and a4. Standard heats of reaction of each component, dHfA, dHfB, dHfC, and dHfD.
HEAT CAPACITIES OF GASES The heat capacity of gases is essential for some process engineering design involving gas-phase chemical reactions. Here, the heat capacities, Cop, for gases are required to determine the heat necessary to bring the chemical compound increase to the reaction temperature. The heat capacity of a mixture of gases may be found from the heat capacities of the individual components contained in the mixtures. The correlation for Cop of the ideal gas at low pressure is a third degree polynomial, which is a function of temperature. Cop = A + BT + CT2 + DT3
(2-111)
where Cop = heat capacity of ideal gas at low pressure, cal/mol K A, B, C, and D = constants for the chemical compounds T = temperature, K The Appendix at the end of this chapter gives values of heat capacity constants.
HEATS OF FORMATION Heats of formation, ∆H of, for individual chemicals involved in chemical reactions are important in determining the heat of reaction, ∆Hor , and associated heating and cooling requirements. If ∆Hor < 0, then
Thermodynamics of Chemical Reactions
81
the chemical reaction is exothermic and will require cooling. If ∆Hor > 0, the reaction is endothermic and heating is therefore required. The correlation of ∆Hof for the ideal gas at low temperature is based on a series expansion in temperature and is expressed as: ∆Hof = A + BT + CT2
(2-112)
where ∆Hof = heat of formation of ideal gas a low pressure, kcal/gmol A, B, and C = correlation constants T = temperature, K The Appendix at the end of this chapter shows heats of formation of some compounds. Example 2-1
Calculate the heat of reaction for the synthesis of ammonia from hydrogen and nitrogen at 1 atm and 155.0°C in N2 + 3H2 → 2NH3 1. kcal/kmol of N2 reacted. 2. kJ/mol of H2 reacted. 3. The true equilibrium constant (K). The heats of formation, the standard molar entropies at 298 K, are given below.
Component N2(g) H2(g) NH3(g)
∆Sos kJ/kmol • K
∆Sos cal/gmol • K
∆Hof kcal/kmol
191.9 130.9 192.9
45.87 31.29 46.10
0.0 0.0 11,020
The heat capacities, expressed as quadratic function of temperature, are shown below: Component N2(g) H2(g) NH3(g)
Cp, kcal/kmol • K 6.457 + 1.39 × 10–3T – 0.069 × 10–6T2 6.946 – 0.196 × 10–3T + 0.476 × 10–6T2 5.92 – 8.963 × 10–3T – 1.764 × 10–6T2
82
Modeling of Chemical Kinetics and Reactor Design
Solution N2 + 3H2 → 2NH3 or
1 2 N 2 + H 2 → NH 3 3 3 Calculate the heat of reaction at the reference temperature using the heats of formation. ∆H orxnT (TR ) = 2 ∆H oFNH − 3∆H oFH − ∆H oFN 3
2
2
The heats of formation of the elements H2, N2 are zero at 298 K. Therefore, ∆H orxn (298 K ) = 2(–11,020) kcal/kmol
kcal = −22, 040 kmol N reacted. 2 The minus sign shows that the heat of reaction is exothermic. Component N2(g) H2(g) NH3(g) ∆
a
b × 10–3
c × 10–6
6.457 6.946 5.92 –15.455
1.39 –0.196 8.963 17.124
–0.069 0.476 –1.764 –4.887
Substituting ∆H orxn (298 K ) and the parameters ∆a, ∆b, and ∆c in Equation 2-110 gives ∆H rxnT (T ) = ∆H orxnT (TR ) + ∆a(T − TR ) + +
∆c 3 (T − TR3 ) 3
∆b 2 T − TR2 ) ( 2
Thermodynamics of Chemical Reactions
83
∆H rxn ( 428K ) = − 22, 040 − 15.455( 428 − 298) + −
17.124 × 10 −3 4282 − 2982 ) ( 2
4.887 × 10 −6 (4283 − 2983 ) 3
∆H rxn ( 428K ) = − 22, 040 − 2, 009.15 + 808.08 − 84.61 − 23, 325.68
kcal kmol N 2
1 kcal = 4.184 kJ = − 97, 594.65
kJ kmol N 2
∆H rxn ( 428K ) =
1 kg mol N 2 3 kg mol H 2
kJ −97, 594.65 kmol N 2
= −32, 531.55
kJ at 428K kg mol H 2
When the reaction proceeds at a constant temperature T, and the reactants and products remain at the standard state (represented by the superscript o), we can use Equation 2-44 to calculate the true equilibrium constant: ∆G = –RT ln K = ∆Hor – T∆So where T
∆H or = ∆H ors +
∫ ∆Cop dT
Ts
(2-44)
84
Modeling of Chemical Kinetics and Reactor Design
and T
∫
∆So = ∆Sso +
Ts
∆C p T
dT
Hence,
∆C p = − 15.455 + 17.124 × 10 −3 T − 4.887 × 10 −6 T 2
cal mol K N 2
and ∆Sso = 2( 46.10) − 45.87 − 3(31.29) = − 47.54
cal mol • K
This is the entropy change for a complete conversion to NH3 where 1 kmol of N2 is converted. The entropy change at 428 K is: 428
∆So = − 47.54 +
∫
298
= − 47.54 +
−15.455 + 17.124 × 10 −3 − 4.887 × 10 −6 T dT T
2 −3 −6 T − 15 . 455 ln T + 17 . 124 × 10 T − 4 . 887 × 10 2 298 428
428 + 17.124 × 10 −3 ( 428 − 298) = −47.54 + [ − 15.455 ln 298
−
4.887 × 10 −6 (4282 − 2982 )] 2
= − 47.54 − 5.595 + 2.226 − 0.231 = − 51.14
cal mol K N 2
Thermodynamics of Chemical Reactions
85
The true equilibrium constant at 428 K is ∆Go = –RT ln K = ∆Ho – T∆S, that is
ln K =
1 o ∆H o ∆S − R T
where
∆H o = − 23, 326
ln K =
cal cal and R = 1.987 mol N 2 mol • K
−23326 1 −51.14 − = 1.691 428 1.987
and K = 5.42 The value of K is very sensitive to small errors in ∆Hor and ∆So and the equilibrium constant belongs to the reaction equation N2 + 3H2 → 2NH3. Table 2-1 shows the calculated results of the heats of reaction at standard state (298 K) and at system temperature of 428 K using the software ENTHALP. Example 2-2
Calculate the heat that must be removed or provided for the gas phase reaction proceeding CO2(g) + 4H2(g) → 2H2O(g) + CH4(g) with 100% conversion and the gas entering at 450°C. The heat of formation at standard conditions and the specific heat capacities are shown below: Component CO2(g) H2(g) H2O(g) CH4(g)
Heat of formation ∆Hf(J/gmol) –393,513 0.0 –241,826 –74,848
86
Modeling of Chemical Kinetics and Reactor Design
Table 2-1 The standard heat of a chemical reaction calculation: aA + bB → cC + dD
∆Cp : J/gmol • K Component
Specific heat capacity equation
CO2(g) H2(g) H2O(g) CH4(g)
Cp Cp Cp Cp
= = = =
26.75 26.88 29.16 13.44
+ + + +
4.226 0.435 1.449 7.703
× × × ×
10–2T 10–2T 10–2T 10–2T
– – – –
1.425 0.033 0.202 1.874
× × × ×
10–5T2 10–5T2 10–5T2 10–5T2
Solution The heat of reaction at the standard state 298 K is: ∆Hrxn(298 K) = 2(–241,826) – 74,848 – (–393,513) – 164,987 J/gmol CO2 Component CO2(g) H2(g) H2O(g) CH4(g) ∆
a
b × 10 –2
c × 10–5
26.75 26.88 29.16 13.44 –62.54
4.226 0.435 1.449 7.703 4.635
–1.425 –0.033 –0.202 –1.874 –0.721
Thermodynamics of Chemical Reactions
∆C p = −62.54 + 4.635 × 10 −2 T − 0.721 × 10 −5 T 2
∆H rxn (723K ) = ∆H rxn (298K ) +
87
J mol K
723
∫
∆C p dT
298
Substituting ∆H orxn (298 K ) and the parameters ∆a, ∆b, and ∆c in Equation 2-110 gives ∆H rxn (723K ) = ∆H rxn (298K ) 723
+
∫ (−62.54 + 4.635 × 10 −2 T − 0.721 × 10 −5 T 2 ) dT
298
∆H rxnT (T ) = ∆H orxnT (TR ) + ∆a(T − TR ) + +
∆b 2 (T − TR2 ) 2
∆c 3 (T − TR3 ) 3
∆H rxn (723K ) = −164, 987 + {−62.54(723 − 298) +
−
4.635 × 10 −2 (7232 − 2982 ) 2 0.721 × 10 −5 (7233 − 2983 ) } 3
= –164,987 – 26,579.5 + 10,056.21 – 844.70 = –182,354.99 = −182, 355
J g mol CO 2
88
Modeling of Chemical Kinetics and Reactor Design
The result shows that –182,355 J/gmol CO2 must be removed. The results of the ENTHALP1 computer program (S.I. units) for the heats of reaction at 298 K and 723 K respectively are shown in Table 2-2. Example 2-3
Using the standard heats of formation of the reaction components, calculate the standard heat of reaction and the heat of reaction at system temperature of 350°C and 1 atm. The reaction is:
α1A + α 2 B → α 3C + α 4 D The system temperature T = 623 K Number of components n = 4 Reaction coefficients α1 = 1, α = 2, α 3 = 1, α 4 = 0 C p = a + b × 10 −2 T + c × 10 −5 T 2 + d × 10 −9 T 3
cal g mol K
Table 2-2 The standard heat of a chemical reaction calculation: aA + bB → cC + dD
Thermodynamics of Chemical Reactions
89
Heat of formation ∆Hf(cal/gmol)
Component A B C D
–26,416 0.0 –48,080 0.0
a
b × 10–2
c × 10–5
d × 10–9
6.726 6.952 4.55 0 –16.08
0.04001 –0.04576 2.186 0 2.23751
0.1283 0.09563 –0.291 0 –0.61056
–0.5307 –0.2079 –1.92 0 –0.9735
Component A B C D ∆
Solution The heat of reaction at the standard state 298 K is: ∆H rxn (298K ) = α 3 ∆H oFC + α 4 ∆H oFD − α1∆H oFA − α 2 ∆H oFB ∆H rxn (298K ) = 1( −48, 080) + 0(0) − 1( −26, 416) − 2 (0) − 21, 664 cal mol ∆H rxn (623K ) = ∆H rxn (298K ) +
623
∫
∆C p dT
298
=
∆H orxn
(298K ) +
623
∫ (∆a + ∆b × 10 −2 T + ∆c × 10 −5 T 2 + ∆d × 10 −9 T 3 ) dT
298
Substituting ∆H orxn (298 K ) and the parameters ∆a, ∆b, and ∆c in Equation 2-110 gives ∆H rxnT (T ) = ∆H orxnT (TR ) + ∆a(T − TR ) + +
∆b 2 (T − TR2 ) 2
∆c 3 (T − TR3 ) + ∆4d (T 4 − TR4 ) 3
90
Modeling of Chemical Kinetics and Reactor Design
∆H rxn (623) = ∆H orxn (298) + +
623
∆aT + 298
∆b × 10 −2 T 2 ∆c × 10 −5 T 3 + 2 3
∆d × 10 −9 T 4 4
= −21, 664 + { − 16.08(623 − 298) +
−
2.23751 × 10 −2 (6232 − 2982 ) 2
0.61056 × 10 −5 (6233 − 2983 ) 0.9735 × 10 −9 (6234 − 2984 ) − } 3 4
= − 21, 664 − 5, 226 + 3, 348.71 − 438.26 − 34.74 = −24, 014.29
cal mol A
Table 2-3 The standard heat of a chemical reaction calculation: aA + bB → cC + dD
Thermodynamics of Chemical Reactions
91
Table 2-3 gives the results of the program for the heats of reaction at 298 K and 623 K, respectively Example 2-4
Experimental values calculated for the heat capacity of ammonia from –40 to 1200°C are shown in Table 2-4. Fit the data by least squares for the following two functions.
C op = a + bT + cT 2 C op = a + bT + cT 2 + dT 3 Solution A computer program, PROG2, was developed to fit the data by least squares of a polynomial regression analysis. The data of temperature (independent variable) versus heat capacity (dependent variable) were inputted in the program for an equation to an nth degree Y = Co + C1X + C2X2 + C3X3 + . . . + CnXn. The results of the computer program for the polynomial regressions of: Cop = a + bT + cT2 and Cop = a + bT + cT2 + dT3 are:
C op = 8.357 + 0.818 × 10 −2 T − 0.16807 × 10 −5 T 2
cal g mol o C
Table 2-4 T °C
Cop cal/gmolT• °C
T °C
Cop cal/gmol • °C
–40 –20 0 18 25 100 200 300 400
8.180 8.268 8.371 8.472 8.514 9.035 9.824 10.606 11.347
500 600 700 800 900 1,000 1,100 1,200
12.045 12.700 13.310 13.876 14.397 14.874 15.306 15.694
Source: Basic Principles and Calculations in Chemical Engineering by David M. Himmelblau, 5th ed., 1989, Prentice Hall International series.
92
Modeling of Chemical Kinetics and Reactor Design
Table 2-5 Polynomial regression analysis for an equation to an nth degree: Y = C0 + C1 • X + C2 • X2 + C3 • X3 + . . . + Cn • Xn
Thermodynamics of Chemical Reactions
93
and
C p = 8.379 + 0.736 × 10 −2 T + 4.074 × 10 −5 T 2 − 1.235 × 10 −9
cal g mol o C
Table 2-5 gives the input data and computer results.
REFERENCES 1. Denbigh, K., The Principles of Chemical Equilibrium, 3rd ed., Cambridge University Press, 1971. 2. Houghen, O. A. and Watson, K. A., Chemical Process Principles, a combined volume consisting of Parts one, two, and three, John Wiley & Sons Inc., 1947. 3. Walas, S. M., Phase Equilibrium In Chemical Engineering, Butterworth Publishers, 1985. 4. Himmelblau, D. M., Basic Principles and Calculations in Chemical Engineering, 5th ed., Prentice-Hall Int. Series, 1989. 5. Fogler, H. S., Elements of Chemical Reaction Engineering, 2nd ed., Prentice-Hall Int. Series, 1986.
94
Modeling of Chemical Kinetics and Reactor Design
Appendix: Heats and Free Energies of Formation
*For footnotes see end of table. 1 kal = 4.184 kJ Source: Adapted from R. H. Perry and C. H. Chilton, Eds., Chemical Engineers’ Handbook, © 1973 McGraw-Hill, Inc. Used with permission of McGraw-Hill Book Company
Thermodynamics of Chemical Reactions
Heats and Free Energies of Formation (continued)
95
96
Modeling of Chemical Kinetics and Reactor Design
Heats and Free Energies of Formation (continued)
Thermodynamics of Chemical Reactions
Heats and Free Energies of Formation (continued))
97
98
Modeling of Chemical Kinetics and Reactor Design
Heats and Free Energies of Formation (continued)
Thermodynamics of Chemical Reactions
Heats and Free Energies of Formation (continued)
99
100
Modeling of Chemical Kinetics and Reactor Design
Heats and Free Energies of Formation (continued)
Thermodynamics of Chemical Reactions
Heats and Free Energies of Formation (continued)
101
102
Modeling of Chemical Kinetics and Reactor Design
Appendix: Heat Combustion
Thermodynamics of Chemical Reactions
103
Combustion Gases (High Range)† Nitrogen Oxygen Air Hydrogen Carbon monoxide Water vapor
Combustion Gases (Low Range) Nitrogen Oxygen Air Hydrogen Carbon monoxide Carbon dioxide Water vapor
Acetylenes and Diolefins Acetylene Methylacetylene Dimethylacetylene Propadiene 1,3-Butadiene Isoprene
H2 CO H 2O
N2 O2
H2 CO CO2 H 2O
N2 O2
C 2H 2 C 3H 4 C 4H 6 C 3H 4 C 4H 6 C 5H 8
6.529 6.732 6.557 6.424 6.480 6.970
6.903 6.085 6.713 6.952 6.726 5.316 7.700
5.21 4.21 3.54 2.43 –1.29 –0.44
a
0.1488 0.1505 0.1477 0.1039 0.1566 0.3464
–0.03753 0.3631 0.04697 –0.04576 0.04001 1.4285 0.04594
2.2008 4.073 5.838 4.693 8.350 10.418
b × 102
–0.02271 –0.01791 –0.02148 –0.007804 –0.02387 –0.04833
0.1930 –0.1709 0.1147 0.09563 0.1283 –0.8362 0.2521
–1.559 –2.192 –2.760 –2.781 –5.582 –6.762
c × 105
— — — — — —
–0.6861 0.3133 –0.4696 –0.2079 –0.5307 1.784 –0.8587
4.349 4.713 4.974 6.484 14.24 16.93
d × 109
273–3800 273–3800 273–3800 273–3800 273–3800 273–3800
273–1800 273–1800 273–1800 273–1800 273–1800 273–1800 273–1800
273–1500 273–1500 273–1500 273–1500 273–1500 273–1500
Temperature Range, K
Appendix: The Molar Heat Capacities of Gases in the Ideal Gas (Zero Pressure) State
104 Modeling of Chemical Kinetics and Reactor Design
CH4 C 2H 6 C 3H 8 C4H10 C4H10 C5H12 C6H14 C 2H 4 C 3H 6 C 4H 8 C 4H 8 C 4H 8 C 4H 8 C5H10 C6H12 C6H12 C7H14
Paraffinic Hydrocarbons Methane Ethane Propane n-Butane i-Butane n-Pentane n-Hexane
Monoolefinic Hydrocarbons Ethylene Propylene 1-Butene i-Butane cis-2-Butene trans-2-Butene
Cycloparafficin Hydrocarbons Cyclopentane Methylcyclopentane Cyclopentane Methylcyclopentane –12.957 –12.114 –15.935 –15.070
0.944 0.753 –0.240 1.650 –1.778 2.340
4.750 1.648 –0.966 0.945 –1.890 1.618 1.657
6.499 6.157 3.918 7.070 7.390 6.222
13.087 15.380 16.454 18.972
3.735 5.691 8.650 7.702 8.078 7.220
1.200 4.124 7.279 8.873 9.936 10.85 13.19
0.5298 1.384 3.483 0.3128 1.489 1.536
–7.447 –8.915 –9.203 –10.989
–1.993 –2.910 –5.110 –3.981 –4.074 –3.403
0.3030 –1.530 –3.755 –4.380 –5.495 –5.365 –6.844
–0.3888 –0.9103 –2.675 0.1364 –1.096 –1.058
16.41 20.03 19.27 24.09
4.220 5.880 12.07 8.020 7.890 6.070
–2.630 1.740 7.580 8.360 11.92 10.10 13.78
0.9520 2.057 7.744 –0.7867 2.760 2.560
Source: O. Hougen, K. Watson, and R. A. Ragatz, Chemical Process Principles, Part 1, John Wiley & Sons, New York, 1954.
S2 SO2 SO3 H 2S CS2 COS
Sulfur Compounds Sulfer Sulfur dioxide Sulfur drioxide Hydrogen sulfide Carbon disulfide Carbonyl sulfide
273–1500 273–1500 273–1500 273–1500
273–1500 273–1500 273–1500 273–1500 273–1500 273–1500
273–1500 273–1500 273–1500 273–1500 273–1500 273–1500 273–1500
273–1800 273–1800 273–1300 273–1800 273–1800 273–1800
Thermodynamics of Chemical Reactions 105
C 6H 6 C 7H 8 C8H10 C 8H 8 C9H12 F2 Cl2 Br2 I2 HF CHl HBr HI CH 3Cl CH2CL2 CHCl3 CCl4 COCl2 CSCl2
Aromatic Hydrocarbons Benzene Toluene Ethylbenzene Styrene Cumene
Halogens and Halogen Acids Fluorine Chlorine Bromine Iodine Hydrogen fluoride Hydrogen chloride Hydrogen bromide Hydrogen iodide
Chloromethanes Methyl chloride Methylene chloride Chloroform Carbon tetrachloride Phosgene Thiophosgene 3.05 4.20 7.61 12.24 10.35 10.80
6.115 6.8214 8.051 8.504 7.201 7.244 7.169 6.702
–8.650 –8.213 –8.398 –5.968 –9.452
a
2.596 3.419 3.461 3.400 1.653 1.859
0.5864 0.57095 0.2462 0.13135 –0.1178 –0.1820 –0.1604 0.04546
11.578 13.357 15.935 14.354 18.686
b × 102
–1.244 –2.3500 –2.668 –2.995 –0.8408 –1.045
–0.4186 –0.5107 –0.2128 –0.10684 0.1576 0.3170 0.3314 0.1216
–7.540 –8.230 –10.003 –9.150 –11.869
c × 105
2.300 6.068 7.344 8.828 — —
0.9797 1.547 0.6406 0.3125 –0.3760 –1.036 –1.161 –0.4813
18.54 19.20 23.95 22.03 28.80
d × 109
The Molar Heat Capacities of Gases in the Ideal Gas (Zero Pressure) State (continued)
273–1500 273–1500 273–1500 273–1500 273–1000 273–1000
273–2000 273–1500 273–1500 273–1800 273–2000 273–1500 273–1500 273–1900
273–1500 273–1500 273–1500 273–1500 273–1500
Temperature Range, K
106 Modeling of Chemical Kinetics and Reactor Design
(CN)2 HCN CNCl CNBr CNI CH3CN CH2CHCN NO NO N 2O NO2 N 2O 4 CH2O C 2H 4 O CH4O C 2H 6 O C 2H 4 O C 2H 2 O C 3H 6 C5H12 C5H12 C8H10 C8H10 C8H10
Cyanogens Cyanogens Hydrogen cyanide Cyanogen chloride Cyanogen bromide Cyanogen iodide Acetonitrile Acrylic nitrile
Oxides of Nitrogen Nitric oxide Nitric oxide Nitrous oxide Nitorgen dioxide Nitrogen tetroxide
Oxygenated Hydrocarbons Formaldehyde Acetaldehyde Methanol Ethanol Ethylene oxide Ketene
Miscellaneous Hydrocarbons Cyclopropane Isopentane Neopentane o-Xylene m-Xylene p-Xylene –6.481 –2.273 –3.865 –3.789 –6.533 –5.334
5.447 4.19 4.55 4.75 –1.12 4.11
6.461 7.008 5.758 5.48 7.9
9.82 6.34 7.97 8.82 9.69 5.09 4.55
8.206 12.434 13.305 14.291 14.905 14.220
0.9739 3.164 2.186 5.006 4.925 2.966
0.2358 –0.02244 1.4004 1.365 4.46
1.4858 0.8375 1.0745 0.9084 0.7213 2.7634 4.1039
–5.577 –7.097 –8.018 –8.354 –8.831 –7.984
0.1703 –0.515 –0.291 –2.479 –2.389 –1.793
–0.07705 0.2328 –0.8508 –0.841 –2.71
–0.6571 –0.2611 –0.5265 –0.4367 –0.3265 –0.9111 –1.6939
15.61 15.86 18.83 18.80 20.05 17.03
–2.078 –3.800 –1.92 4.790 3.149 4.22
0.08729 –1.000 2.526 1.88 —
— — — — — — —
273–1000 273–1500 273–1500 273–1500 273–1500 273–1500
273–1500 273–1000 273–1000 273–1500 273–1000 273–1500
273–3800 273–1500 273–1500 273–1500 273–600
273–1000 273–1500 273–1000 273–1000 273–1000 273–1200 273–1000
Thermodynamics of Chemical Reactions 107
C 3O 2 C 3O 6 O C 3O 8 O C 3O 8 O C 3O 6 O C2H3Cl C2H2Cl2 C2H2Cl2 C2H2Cl2 C2HCl3 C2Cl4 NH3 N 2H 4 CH5N C 2H 2 N C 3H 9 N
C3 Oxygenated Hydrocarbons Carbon suboxide Acetone I-Propyl alcohol n-Propyl alcohol Allyl alcohol
Chloroethenes Chloroethene 1,1-Dichloroethene cis-1,2-Dichloroethene trans-1,2-Dichloroethene Trichloroethene Tetrachloroethene
Nitrogen Compounds Ammonia Hydrazine Methylamine Dimethylamine Trimethylamine 6.5846 3.890 2.9956 –0.275 –2.098
2.401 5.899 4.336 5.661 9.200 15.11
8.203 1.625 0.7936 –1.307 0.5203
a
0.61251 3.554 3.6101 6.6152 9.6187
4.270 4.383 4.691 4.295 4.517 3.799
3.073 6.661 8.502 9.235 7.122
b × 102
0.23663 –2.304 –1.6446 –3.4826 –5.5488
–2.751 –3.182 –3.397 –3.022 –3.600 –3.179
–2.081 –3.737 –5.016 –5.800 –4.259
c × 105
–1.5981 5.990 2.9505 7.1510 12.432
6.797 8.516 9.010 7.891 10.10 9.089
5.182 8.307 11.56 14.14 9.948
d × 109
The Molar Heat Capacities of Gases in the Ideal Gas (Zero Pressure) State (continued)
273–1500 273–1500 273–1500 273–1500 273–1500
273–1500 273–1500 273–1500 273–1500 273–1500 273–1500
273–1500 273–1500 273–1500 273–1500 273–1500
Temperature Range, K
108 Modeling of Chemical Kinetics and Reactor Design
Reaction Rate Expression
109
CHAPTER THREE
Reaction Rate Expression INTRODUCTION Chemical reactions are processes in which reactants are transformed into products. In some processes, the change occurs directly and the complete description of the mechanism of the reaction present can be relatively obtained. In complex processes, the reactants undergo a series of step-like changes and each step constitutes a reaction in its own right. The overall mechanism is made up of contributions from all the reactions that are sometimes too complex to determine from the knowledge of the reactants and products alone. Chemical kinetics and reaction mechanism as reviewed in Chapter 1 can often provide a reasonable approach in determining the reaction rate equations. Chemical kinetics is concerned with analyzing the dynamics of chemical reactions. The raw data of chemical kinetics are the measurements of the reactions rates. The end product explains these rates in terms of a complete reaction mechanism. Because a measured rate shows a statistical average state of the molecules taking part in the reaction, chemical kinetics does not provide information on the energetic state of the individual molecules. Here, we shall examine a series of processes from the viewpoint of their kinetics and develop model reactions for the appropriate rate equations. The equations are used to arrive at an expression that relates measurable parameters of the reactions to constants and to concentration terms. The rate constant or other parameters can then be determined by graphical or numerical solutions from this relationship. If the kinetics of a process are found to fit closely with the model equation that is derived, then the model can be used as a basis for the description of the process. Kinetics is concerned about the quantities of the reactants and the products and their rates of change. Since reactants disappear in reactions, their rate expressions are given a 109
110
Modeling of Chemical Kinetics and Reactor Design
negative sign. The amounts of the products increase and their rates of change are therefore positive.
REACTION RATE EQUATION The rate of a reaction is the number of units of mass of some participating reactants that is transformed into a product per unit time and per unit volume of the system. The rate of a closed homogeneous reaction (that is, no gain or loss of material during the reaction) is determined by the composition of the reaction mixture, the temperature, and pressure. The pressure from an equation of state can be determined together with the temperature and composition. Consider a single-phase reaction aA + bB → cC + dD
(3-1)
The reaction rate for reactant A can be expressed as
(− rA ) = −
1 dN A (amount of A disappearing) = V dt ( volume)(time) =
moles m 3 • sec
(3-2)
where the minus sign means “disappearance” and (–rA) = NA = V= t =
rate of disappearance of A number of moles system volume time
The reaction rates of the individual components are related by r − rA −r r = B = C = D a b c d
(3-3)
The rate is defined as an intensive variable, and the definition is independent of any particular reactant or product species. Because the reaction rate changes with time, we can use the time derivative to express the instantaneous rate of reaction since it is influenced by the composition and temperature (i.e., the energy of the material). Thus,
Reaction Rate Expression
(–rA) = f{temperature, concentration}
111
(3-4)
The Swedish chemist Arrhenius first suggested that the temperature dependence of the specific reaction rate k could be correlated by an equation of the type k(T) = koe–E/RT. Therefore, (–rA) = kCAa = koe–E/RTCAa where E = ko = a = CA = T= R =
activation energy (J/mol) frequency factor reaction order concentration of reactant A absolute temperature, K gas constant = 1.987 cal/mol • K = 8.314 J/mol •K
The reaction rate usually rises exponentially with temperature as shown in Figure 3-1. The Arrhenius equation as expressed in Chapter 1 is a good approximation to the temperature dependency. The temperature dependent term fits if plotted as ln (rates) versus 1/T at fixed concentration CA, CB (Figure 3-2). At the same concentration, but two different temperatures,
ln
rate1 k E 1 1 = ln 1 = − rate 2 k 2 R T2 T1
Figure 3-1. Reaction rate as a function of temperature.
(3-5)
112
Modeling of Chemical Kinetics and Reactor Design
Figure 3-2. Temperature dependency of the reaction rate.
High values of the activation energy E are examples of gas phase reaction, which can only proceed at a high temperature (examples are free radical reactions and combustion). Low values of E can be found in enzymes, cellular and life related reactions, and reactions that occur at room temperature. Composition affects the rate of reaction by fitting a simple expression to the data as shown in Figure 3-3. The concentration dependent term is found by guessing the rate equation, and seeing whether or not it fits the data. Boudart [1] expressed the many variables that have influenced reaction rates as: 1. The rate of a chemical reaction depends on temperature, pressure, and composition of the system under investigation. 2. Certain species that do not appear in the stoichiometric equation for the reaction can affect the reaction rate even when they are present in only trace amounts. These materials are known as catalysts or inhibitors, depending on whether they increase or decrease the reaction rate. 3. At a constant temperature, the rate of reaction decreases with time or extent of the reaction. 4. Reactions that occur in systems that are far removed from equilibrium give the rate expressions in the form:
Reaction Rate Expression
113
Figure 3-3. Reaction rate as a function of concentration.
r = kf(CAi)
(3-6)
where f(CAi) is a function that depends on the concentration (CA) of the various species present in the system, such as reactants, products, catalysts, and inhibitors. The function f(CAi) may also depend on the temperature. The coefficient k is the reaction constant. It does not depend on the composition of the system and is also independent of time in an isothermal system. 5. The rate constant k varies with the absolute temperature T of the system according to the Arrhenius law: k = koe–E/RT. 6. The function f(CAi) in Equation 3-6 is temperature independent and can be approximated as:
f (C Ai ) = ∏ i Cβi i
(3-7)
where the product ∏ is taken over all components of the system. The exponents βi are the orders of the reaction with respect to each of the species present in the system. The algebraic sum of the exponents is called the total order or overall order of the reaction. 7. For a system in which both forward and reverse reactions are important, the net rate of reaction can be expressed as the difference between the rate in the forward direction and that in the opposite direction. For example:
114
Modeling of Chemical Kinetics and Reactor Design k1
A+B{C+D k2
(3-8)
The rate of the forward direction (–rA) is : (–rA) = k1CACB
(3-9)
and the rate of the reverse direction (+rA) is: (+rA) = k2CCCD
(3-10)
The overall rate is: (–rA)net = (–rA) – (+rA)
(3-11)
The net rate of disappearance of A = k 1C AC B – k 2 C CC D at equilibrium where (–rA)net = 0. Therefore,
r k1 C C C D s = = KC k C A C B Equilibrium
(3-12)
REACTION ORDERS The manner in which the reaction rate varies with the concentrations of the reactants and products can be shown by the orders of the reaction. These are the powers to which the concentrations are raised and are expressed as: (–rA) = kCαACβ
(3-13)
where αth is the order with respect to component A, and βth is the order with respect to component B. The overall order of the reaction n is: n = α+ β
(3-14)
The exponents α and β may be integers or fractions and may be both positive and negative values, as well as the value of zero. In some cases, the exponents are independent of temperature. Where the
Reaction Rate Expression
115
experimental data fit the expressions in the form of Equation 3-13, the exponents will vary slightly with temperature. In these cases, the observed correlation should be applied only in a restricted temperature interval. Not all reactions can be expressed to have a specific order. A specific example is the synthesis of ammonia expressed as
N 2 + 3H 2
k1
{ 2 NH 3 k 2
The Temkin-Pyzhev equation describes the net rate of synthesis over promoted iron catalyst as:
(+ r ) NH 3
C 3H = k1C N 2 2 2 net C NH 3
a
C 2NH 3 − k2 3 CH2
b
(3-15)
where a and b are empirical exponents that vary with reaction conditions such as temperature, pressure, and conversion. Equation 3-15 does not describe the initial rate at zero partial pressure of NH3. The units of the reaction rate constant k vary with the overall order of the reaction. These units are those of a rate divided by the nth power of concentration as evident from Equations 3-13 and 3-14. k=
(− rA ) = C
n
moles ( volume − time)
(moles volume)n
(3-16)
or k = time −1 ( moles)1− n moles = time −1 volume
1 ( volume)1− n − n +1
(3-17)
Consider a reaction involving a reactant such that A → products. The rate equations corresponding to a zero, first, second, and third order reaction together with their corresponding units are:
116
Modeling of Chemical Kinetics and Reactor Design
1. Zero order (n = 0; k = moles/m3-sec) (–rA) = kC0A
(3-18)
2. First order (n = 1; k = 1/sec) (–rA) = kCA
(3-19)
3. Second order (n = 2; k = m3/moles-sec) (–rA) = kCA2
(3-20)
4. Third order (n = 3; k = (m3/moles)2•sec–1) (–rA) = kCA3
(3-21)
DETERMINING THE ORDER OF REACTIONS ZERO ORDER REACTIONS The rate of a chemical reaction is of a zero order if it is independent of the concentrations of the participating substances. The rate of reaction is determined by such limiting factors as: 1. In radiation chemistry, the energy, intensity, and nature of radiation. 2. In photochemistry, the intensity and wave length of light. 3. In catalyzed processes, the rates of diffusion of reactants and availability of surface sites. If the rate of the reaction is independent of the concentration of the reacting substance A, then the amount dCA by which the concentration of A decreases in any given unit of time dt is constant throughout the course of the reaction. The rate equation for a constant volume batch system (i.e., constant density) can be expressed as:
(− rA ) = −
dC A =k dt
(3-22)
The negative sign indicates that the component A is removed from the system, and k is the velocity constant with the units as moles/m3sec. Assuming that at time t1 the concentration of A is CAO, and at
Reaction Rate Expression
117
time t2 the concentration is CAf, integrating Equation 3-22 between these limits gives:
−
C Af
∫
C AO
t2
dC A = k ∫ dt
(3-23)
t1
−(C Af − C AO ) = k( t 2 − t1 ) k=
(C AO − C Af ) ( t 2 − t1 )
(3-24)
If t1 = 0, Equation 3-24 reduces to CAf = CAO – kt2
(3-25)
Plotting the concentration (CA) versus time t gives a straight line, where CAO is the intercept and k is the slope. The velocity constant k may include arbitrary constants resulting from various limiting factors such as diffusion constants and a fixed intensity of absorbed light. In terms of the fractional conversion XA CAOXA = kt
(3-26)
Because CA cannot be negative, the following is obtained C AO − C A = C AO X A = kt for t <
C AO k
(3-27)
This means that the conversion is proportional to time. Figure 3-4 shows plots of the zero order rate equations. Examples of zero order reactions are the intensity of radiation within the vat for photochemical reactions or the surface available in certain solid catalyzed gas reactions. FIRST ORDER REACTIONS
k → B . The rate of a first order reaction Consider the reaction A is proportional to the first power of the concentration of only one component. Assuming that there is no change in volume, temperature,
118
Modeling of Chemical Kinetics and Reactor Design
Figure 3-4. Zero order reaction.
or any other factor that may affect the reaction, the amount dCA that undergoes a chemical change in the short time interval dt depends only on the amount of component A present at that instant. The rate for a first order reaction for a constant volume batch system (i.e., constant density) can be expressed as:
(− rA ) =
− dC A = kC A dt
(3-28)
Reaction Rate Expression
119
Rearranging and integrating Equation 3-28 between the limits gives
−
C Af
t
2 dC A = k ∫ dt CA t
∫
C AO
(3-29)
1
C Af − ln C A = k( t 2 − t1 ) C AO
(3-30)
− ln [C Af − C AO ] = k( t 2 − t1 )
(3-31)
− ln
C Af = k ( t 2 − t1 ) C AO
(3-32)
At t1 = 0 and t2 = t. Therefore, − ln
C Af = kt C AO
(3-33)
The fractional conversion XA for a given reactant A is defined as the fraction of the reactant converted into product or
XA =
N AO − N A N AO
(3-34)
For a constant density system, the volume V remains constant CA =
N (1 − X A ) NA = AO = C AO (1 − X A ) V V
(3-35)
Differentiating Equation 3-35 gives dCA = –CAOdXA
(3-36)
Substituting Equation 3-36 into Equation 3-28 gives
dX A = k(1 − X A ) dt
(3-37)
120
Modeling of Chemical Kinetics and Reactor Design
Rearranging and integrating Equation 3-37 between the limits t = 0, XA = 0 and t = tf and XA = XAf gives X Af
∫ 0
t
f dX A = k ∫ dt (1 − X A ) 0
− ln (1 − X Af ) = kt f
(3-38)
A plot of –ln(1 – XA) or –ln CAf/CAO versus t gives a straight line through the origin. The slope of the line is the velocity constant k, as represented by Figure 3-5. The unit of the velocity constant k is sec–1. Many reactions follow first order kinetics or pseudo-first order kinetics over certain ranges of experimental conditions. Examples are the cracking of butane, many pyrolysis reactions, the decomposition of nitrogen pentoxide (N2O5), and the radioactive disintegration of unstable nuclei. Instead of the velocity constant, a quantity referred to as the half-life t1/2 is often used. The half-life is the time required for the concentration of the reactant to drop to one-half of its initial value. Substitution of the appropriate numerical values into Equation 3-33 gives k=
1. 0.693 ln 2 = t1 2 t1 2
Figure 3-5. First order reaction.
(3-39)
Reaction Rate Expression
121
Equation 3-39 shows that in the first order reactions, the half-life is independent of the concentration of the reactant. This basis can be used to test whether a reaction obeys first order kinetics by measuring half-lives of the reaction at various initial concentrations of the reactant.
SECOND ORDER REACTIONS A second order reaction occurs when two reactants A and B interact in such a way that the rate of reaction is proportional to the first power of the product of their concentrations. Another type of a second order reaction includes systems involving a single reactant. The rate at any instant is proportional to the square of the concentration of a single reacting species. Case 1 k Consider the reaction A + B → products . The rate equation for a constant volume batch system (i.e., constant density) is:
(− rA ) =
− dC A − dC B = = kC A C B dt dt
(3-40)
The amount of A and B that have reacted at any time t can be described by the following mechanism and set of equations. From stoichiometry: Amount at time t = 0 Amount at time t = t Amounts that have reacted
CB = CBO – (CAO – CA)
A
B
CAO CA CAO – CA
CBO CB CBO – CB
(3-41)
Substituting Equation 3-41 into Equation 3-40, rearranging and integrating between the limits gives CA
∫
C AO
t
[
C A C BO
− dC A = k ∫ dt − (C AO − C A ) 0
]
(3-42)
122
Modeling of Chemical Kinetics and Reactor Design
Equation 3-42 is resolved into partial fractions as 1 p ≡ + CA C A (C BO − C AO ) + C A
[
]
[
q (C BO − C AO ) + C A
[
]
(3-43)
]
1 ≡ p (C BO − C AO ) + C A + qC A
(3-44)
Equating the coefficients of CA and the constant on both the right and left side of Equation 3-44 gives “Const”
1 = p(CBO –CAO)
“CA”
0 = p + q
where p = 1/(CBO – CAO)
(3-45)
and q = –1/(CBO –CAO)
(3-46)
Substituting p and q into Equation 3-43 and integrating between the limits gives
C A dC A − ∫ − C AO (C BO − C AO ) C A
CA
∫
C AO
dC A (C BO − C AO ) (C BO − C AO ) + C A
[
]
t
= k ∫ dt
(3-47)
C (C BO − C AO ) + C A 1 AO ln ln + = kt (C BO − C AO ) C A (C BO − C AO + C AO )
(3-48)
C (C − C AO ) + C A ln AO BO = k(C BO − C AO ) t CA C BO
(3-49)
0
Reaction Rate Expression
123
Figure 3-6 shows that a plot of C (C − C AO ) + C A ln AO BO CA C BO versus time t gives a straight line with the slope k(CBO – CAO). If CBO is much larger than CAO, then the concentration of B remains approximately constant, and Equation 3-49 approaches Equations 3-33 or 3-38 for the first order reaction. Therefore, the second order reaction becomes a pseudo-first order reaction. Case 2 Case 2 involves a system with a single reactant. In this case, the rate at any instant is proportional to the square of the concentration k → products . The rate expresof A. The reaction mechanism is 2A sion for a constant volume batch system (i.e., constant density) is
(− rA ) =
− dC A 2 = kC 2A = kC 2AO (1 − X A ) dt
Figure 3-6. Test for the reaction A + B → products.
(3-50)
124
Modeling of Chemical Kinetics and Reactor Design
Rearranging Equation 3-50 and integrating between the limits yields CA
∫
C AO
t
− dC A = k ∫ dt C 2A 0
(3-51)
CA
1 = kt CA
(3-52)
C AO
1 1 − = kt C A C AO
(3-53)
1 1 = + kt C A C AO
(3-54)
or
In terms of the fractional conversion, XA, Equation 3-50 becomes C AO dX A 2 = kC 2AO (1 − X A ) dt
(3-55)
Rearranging Equation 3-55 and integrating gives XA
dX A
∫ (1 − X )2 A 0
t
= kC AO ∫ dt
(3-56)
0
Equation 3-56 yields XA
1 = kC AO t (1 − X A ) 0
Equation 3-57 gives
(3-57)
Reaction Rate Expression
XA = kC AO t (1 − X A )
125
(3-58)
Figure 3-7 gives plots of Equations 3-54 and 3-58, respectively. k → products , which is Consider the second order reaction 2A + B first order with respect to both A and B, and therefore second order overall. The rate equation is:
Figure 3-7. Test for the reaction 2A → products.
126
Modeling of Chemical Kinetics and Reactor Design
(− rA ) =
− dC A = kC A C B dt
(3-59)
From stoichiometry:
Amount at time t = 0 Amount at time t = t Amounts that have reacted
A
B
CAO CA (CAO –CA)
CBO CB CBO –CB
and from stoichiometry (CAO – CA) = 2(CBO – CB). Expressing the concentration of B in terms of A and the original amounts CAO, CBO gives
C B = C BO −
1 (C AO − C A ) 2
(3-60)
Substituting Equation 3-60 into Equation 3-59 gives CA
∫
C AO
−
CA
∫
t
− dC A = ∫ dt 1 kC A C BO − (C AO − C A ) 0 2
C AO
(3-61)
t
dC A = k ∫ dt 1 1 0 C A C BO − C AO + C A 2 2
(3-62)
Taking the partial fractions of Equation 3-62 with α = [CBO – (1/2)CAO] gives the following:
1 1 C A α + C A 2
≡
p q + CA α + 1 C A 2
1 1 ≡ p α + C A + qC A 2
(3-63)
(3-64)
Solving for constants p and q involves equating the “constant” and the coefficient of “CA” in Equation 3-64:
Reaction Rate Expression
“Const” “CA”
p=
127
1 = αp
(3-65)
1 0= p +q 2
(3-66)
1 α
(3-67)
−1 −1 p= 2 2α
(3-68)
and q=
Substituting the values of p and q into Equation 3-68 and integrating between the limits gives
CA
∫
C AO
C CA A − dC A dC A dC A = − ∫ − ∫ 1 1 C AO αC A C AO 2α α + C A C A α + C A 2 2 t
= k ∫ dt
(3-69)
0
1 C 1 2α + C A − ln A − ln = kt α C AO α 2α + C AO
(3-70)
C AO 2α + C A + ln ln = αkt 2α + C AO C A
(3-71)
since 2α + CAO = 2CBO 2α + CA = 2CB
128
Modeling of Chemical Kinetics and Reactor Design
C C ln AO • B = αkt C A C BO
(3-72)
A plot of ln(CAO/CA × CB/CBO) versus time t gives a straight line with the slope αk as shown in Figure 3-8. Examples of bimolecular reactions with rate equations similiar to those given in Equation 3-40 are shown in Table 3-1.
Figure 3-8. Test for the reaction 2A + B → products.
Table 3-1 Second order reaction 1. Alkaline hydrolysis of esters: CH 3COOC 2 H 5 + NaOH → CH 3COONa + C 2 H 5 OH 2. Bromination of alkenes: CH 3CH 2 = CH 2 + Br2 → CH 3CHBrCH 2 Br 3. Nucleophilic substitution: Cl − + CH 3 I → CH 3Cl + I −
4. Nitroethane iodination: C 2 H 5 NO 2 + C 6 H 5 N → C 2 H 4 NO 2 + C 5 H 5 NH + + I −
Reaction Rate Expression
129
EMPIRICAL RATE EQUATIONS OF THE nth ORDER IRREVERSIBLE REACTIONS The rate equation for irreversible reactions for a constant volume batch system (i.e., constant density) is
(− rA ) =
− dC A n = kC A dt
(3-73)
Boundary conditions are: at t = 0, CA = CAO and t = t, CA = CA. Integrating Equation 3-73 between the limits gives CA
∫
C AO
t
− dC A = ∫ dt n CA 0
(3-74)
C
C − n +1 A − A = kt − n + 1 C AO
1
( n − 1)
(3-75)
{C1A− n − C1AO− n } = kt
−n C1A− n − C1AO = ( n − 1)kt
(3-76)
(3-77)
The value of n must be found by trial-and-error. In terms of the fractional conversion, XA, the rate equation is
(− rA ) = C AO
dX A n = kC AO (1 − X A )n dt
(3-78)
Boundary conditions are: at t = 0, XA = 0, and t = t, XA = XA. Rearranging and integrating Equation 3-78 between the limits gives XA
dX A
∫ (1 − X )n A 0
t
n −1 = kC AO ∫ dt 0
(3-79)
130
Modeling of Chemical Kinetics and Reactor Design X
(1 − X A ) − n +1 A n −1 = kC AO t 1 − n 0
(3-80)
(1 − X A )1− n
(3-81)
n −1 − 1 = kC AO (1 − n )t
Table 3-2 gives solutions for some chemical reactions using the integration method.
METHOD OF HALF-LIFE t1/2 As previously discussed, the half-life of a reaction is defined as the time it takes for the concentration of the reactant to fall to half of its initial value. Determining the half-life of a reaction as a function of the initial concentration makes it possible to calculate the reaction order and its specific reaction rate. Consider the reaction A → products. The rate equation in a constant volume batch reaction system gives
(− rA ) =
− dC A n = kC A dt
(3-82)
Rearranging and integrating Equation 3-82 with the boundary conditions t = 0, CA = CAO and t = t, CA = CA gives
−
CA
∫
C AO
t
dC A = ∫ dt n CA 0
(3-83)
C
− n +1 CA A − = kt − n + 1 C
(3-84)
C 1 C1A− n } A = kt { C AO ( n − 1)
(3-85)
{C1A− n − C1AO− n } = kt(n − 1)
(3-86)
AO
a The equations for the zero order reaction are true for any stoichiometry, but the relationship between the rate constants depends on the stoichImetry. b In the the autocatalytic case some product must be present initially (at concentration x0) otherwise the reaction will never start. Source: Laidler, K. J., Chemical Kinetics, 3rd ed. Harper Collins Publishers, 1987.
Table 3-2 Rate equations for irreversible processes
Reaction Rate Expression 131
132
Modeling of Chemical Kinetics and Reactor Design
or
t=
1 {C1A− n − C1AO− n } k( n − 1)
(3-87)
The half-life is defined as the time required for the concentration to drop to half of its initial value, that is, at t = t1/2, CA = 1/2CAO. From Equation 3-86,
(2 −1 C AO )1− n − C1AO− n = kt1 2 (n − 1)
(3-88)
(2 −1 • 2 n − 1) C1AO− n = kt1 2 (n − 1)
(3-89)
t1 2
−n 2 n −1 − 1)C1AO ( =
k( n − 1)
(3-90)
Similarly, the time required for the concentration to fall to 1/p of its initial value gives t1 p =
(p n −1 − 1)C1AO− n k( n − 1)
(3-91)
Taking the natural logarithm of both sides of Equation 3-90 gives ln t1 2 = ln (2 n −1 − 1) + (1 − n ) ln C AO − ln k − ln ( n − 1)
(3-92)
2 n −1 − 1 ln t1 2 = ln + (1 − n ) ln C AO k( n − 1)
(3-93)
Plots of ln t1/2 versus ln CAO from a series of half-life experiments are shown in Figure 3-9. Table 3-3 gives some expressions for reaction half-lives. The reaction rate constant k is k=
(2 n −1 − 1) C1AO− n ( n − 1) t1 2
(3-94)
Reaction Rate Expression
133
Figure 3-9. Overall order of reaction from a series of half-life experiments each at different initial concentration of reactant.
Table 3-3 Expressions for Reaction Half-Lives Order
Half-life t1/2
Single reaction substance A
Order
Half-life t1/2
Reactants in their stoichiometric ratios; A + . . . → Z
0
a0 2k A
0
a0 2k A
1
ln 2 kA
1(υA = kA[A])
ln 2 kA
2
1 k Aa 0
3
3 2 k A a 20
n
2 n −1 − 1 k A ( n − 1)a 0n −1
2(υA = kA[A][B])
3(υA = kA[A][B][C])
1 1 = k Aa 0 k A b0 3 2k A b 0c0
Source: Laidler, K. J., Chemical Kinetics, 3rd ed., Harper Collins Publishers, 1987.
134
Modeling of Chemical Kinetics and Reactor Design
The half-life method requires data from several experiments, each at different initial concentration. The method shows that the fractional conversion in a given time rises with increased concentration for orders greater than one, drops with increased concentration for orders less than one, and is independent of the initial concentration for reactions of first order. This also applies to the reaction A + B → products when CAO = CBO.
PARALLEL REACTIONS k
k
2 → C . The Consider elementary reactions A 1 → B and A rate equations for these reactions for a constant volume batch system (i.e., constant density) are
(− rA ) =
− dC A = k1C A + k 2 C A = ( k1 + k 2 ) C A dt
(3-95)
(+ rB ) =
dC B = k1C A dt
(3-96)
(+ rC ) =
dC C = k 2C A dt
(3-97)
Rearranging and integrating Equation 3-95 between the limits with the boundary conditions at time t = 0, CA = CAO, CB = CBO, CC = CCO, gives: −
CA
∫
C AO
− ln
t
dC A = ( k1 + k 2 )dt C A ∫0
CA = ( k 1 + k 2 )t C AO
(3-98)
(3-99)
In terms of the fractional conversion − ln (1 − X A ) = ( k1 + k 2 )t
(3-100)
If –ln CA/CAO or –ln (1 – XA) is plotted against time t, the slope of the line is (k1 + k2). Also, dividing Equation 3-96 by Equation 3-97 gives
Reaction Rate Expression
rB dC B k1 = = rC dC C k 2
135
(3-101)
Integrating Equation 3-101 between the limits yields
C B − C BO k1 = C C − C CO k 2
(3-102)
k1 k1 or C B − C BO = k C C − k C CO 2 2
(3-103)
Therefore, the slope of the linear plot CB versus CC gives the ratio k1/k2. Knowing k1 + k2 and k1/k2, the values of k1 and k2 can be determined as shown in Figure 3-10. Concentration profiles of components A, B, and C in a batch system using the differential Equations 3-95, 3-96, 3-97 and the Runge-Kutta fourth order numerical method for the case when CBO =CCO = 0 and k1 > k2 are reviewed in Chapter 5. An example of parallel reactions involves the two modes of decomposition of an alcohol: C2H5OH = C2H4 + H2O
(3-104)
C2H5OH = CH3CHO + H2
(3-105)
Figure 3-10. Rate constants for two competing elementary first order reactions.
136
Modeling of Chemical Kinetics and Reactor Design
Generally, these occur simultaneously. The relative amount of ethylene and acetaldehyde obtained therefore depends on the relative speed of the two reactions competing with each other for the available alcohol. These speeds, in turn, are determined by the choice of catalyst and temperature. Parallel reactions often have mechanisms of different reaction order. An example is the solvolysis reactions in the presence of added nucleophiles: C 6 H 5SO 2 Cl + H 2 O 1 → C 6 H 5SO 2 OH + H + + Cl − k
C 6 H 5SO 2 Cl + F −
k2 H 2 O→
C 6 H 5SO 2 F + Cl −
(3-106)
In the solvolysis reaction, H2O is the solvent as well as a reactant, and it is present in large excess. It does not appear in the rate equation, which is expressed by k
A 1 → C
(3-107)
k
2 A + B →D
(3-108)
The rate equation is:
(− rA )net = −
dC A = k1C A + k 2 C A C B dt
(3-109)
An excess of component B is used, and its concentration remains constant, so that the rate equation reduces to a first order. That is,
−
dC A = K eCA dt
(3-110)
where K e = k 1 + k 2C B
(3-111)
Measurements of Ke at different concentrations of B will enable the rate constants for each of the reactions to be determined. Parallel reactions give a reduction in the yield of the product. This can be
Reaction Rate Expression
137
improved by incorporating a method that favors the required reaction over the unwanted reaction.
HOMOGENEOUS CATALYZED REACTIONS A catalyzed reaction can be expressed as k
A 1 → P
(uncatalyzed)
k
2 A + C → P+C
(catalyzed)
(3-112) (3-113)
where C and P represent the catalyst and product respectively. The reaction rates for a constant volume batch system (i.e., constant density) are:
(− rA ) = −
dC A = k1C A dt 1
(3-114)
(− rA ) = −
dC A = k 2C ACC dt 2
(3-115)
The overall rate of disappearance of reactant A is:
−
dC A = k1C A + k 2 C A C C dt
(3-116)
The catalyst concentration remains unchanged and integrating Equation 3-116 with the boundary conditions: t = 0, CA = CAO and t = t, CA = CA
−
CA
(3-117)
CA = ( k1 + k 2 C C ) t = Kt C AO
(3-118)
C AO
− ln
t
∫ (k1 + k 2CC )dt
∫
dC A = CA
0
where K = k1 + k2CC.
138
Modeling of Chemical Kinetics and Reactor Design
In this case, a series of experiments are performed with varying catalyst concentrations. A plot is made of K = (k1 + k2CC) versus CC. The slope of the straight line is k2 and the intercept is k1, as shown in Figure 3-11.
AUTOCATALYTIC REACTIONS This type of reaction occurs when one of the products of the reactions acts as a catalyst, and is expressed by k A+B → B+ B
(3-119)
The rate equation for a constant volume batch system is:
(− rA )
=−
dC A = kC A C B dt
(3-120)
When A is consumed, then the total moles of A and B remain unchanged at any time t and can be expressed as CO = CA + CB = CAO + CBO = constant. Then the rate equation becomes
(− rA ) = −
dC A = kC A (C O − C A ) dt
(3-121)
Figure 3-11. Rate constants for a homogeneous catalyzed reaction from a series of experiments with different catalyst concentrations.
Reaction Rate Expression
139
Rearranging Equation 3-121 and integrating between the limits gives CA
∫
C AO
t
dC A − = kdt C A (C O − C A ) ∫0
(3-122)
Converting the left side of Equation 3-122 into partial fractions gives 1 p q ≡ + C A (C O − C A ) C A C O − C A
(3-123)
1 ≡ p(CO – CA) + qCA Equating the coefficients Constant 1 = pCO “CA” 0 = –p + q p = q p=q=
1 CO
Integrating Equation 3-122 between the limits gives CA t C A 1 dC dC A 1 A − ∫ + ∫ = k ∫ dt C C C (C O − C A ) C AO O 0 C AO O A
(3-124)
C − C A C 1 1 − ln A − ln O = kt C O C AO C O C O − C AO C B C BO C C − C A = C O kt ln AO O = ln C A C AO C A C O − C AO
(3-125)
The fractional conversion, XA, and the initial reaction ratio, θB = CBO/CAO, yields
140
ln
Modeling of Chemical Kinetics and Reactor Design
θB + X A = C AO (θ B + 1) kt = (C AO + C BO ) kt θ B (1 − X A )
(3-126)
For an autocatalytic reaction some product B must be present if the reaction is to proceed. Starting with a small concentration of B, the rate rises as B is formed, and when A is used up, the rate must drop to zero. A plot of concentration versus time gives a straight line through the origin as shown in Figure 3-12.
IRREVERSIBLE REACTIONS IN SERIES k
k
2 → C . The Consider a first order reaction in series as A 1 → B rate equations for a constant volume batch system (i.e., constant density) are:
(− rA ) = −
dC A = k1C A dt
(− rB )net = −
(+ rC ) =
dC B = k 2 C B − k1C A dt
dC C = k 2CB dt
Figure 3-12. Autocatalytic reaction.
(3-127)
(3-128)
(3-129)
Reaction Rate Expression
141
The initial conditions are at time t = 0, CA = CA0 and CB = 0, CC = 0. From stoichiometry:
Amount at time t = 0 Amount at time t = t Amounts that have reacted
A
B
C
CAO CA CAO – CA
0 CB CB
0 CC CC
and from stoichiometry CAO – CA = CB = CC. From Equation 3-127, the concentration of A is obtained by integration
dC A = − k1C A dt CA
∫
C AO
ln
(3-130) t
dC A = − k1 ∫ dt dt 0
(3-131)
CA = − k 1t C AO
Therefore, C A = C AO e − k1t
(3-132)
The variation in concentration of B is obtained by substituting the concentration of A from Equation 3-132 into Equation 3-128:
dC B + k 2 C B = k1C AO e − k1t dt
(3-133)
Equation 3-133 is a first order linear differential equation of the form dy/dx + Py = Q. The integrating factor is IF = e∫Pdx, and the solution is ye∫Pdx = ∫Qe∫Pdxdx + Constant. Applying this general procedure to Equation 3-133, the integrating factor is IF = e ∫ k 2 dt . Multiplying Equation 3-133 by the integrating factor gives
e∫
k 2 dt
dC B k dt k dt + k 2 C Be ∫ 2 = k1C A e ∫ 2 dt
(3-134)
142
Modeling of Chemical Kinetics and Reactor Design
(
)
d k dt C Be k 2 t = k1C A e ∫ 2 dt
(3-135)
C Be k 2 t = ∫ k1C A e ∫
(3-136)
k 2 dt
dt + Const.
where Const. = constant.
= k1C AO ∫ e − k1t • e k 2 t dt + Const.
(3-137)
= k1C AO ∫ e ( k 2 − k1 ) t dt + Const.
(3-138)
k1C AO e ( k 2 − k1 ) t ( k 2 − k1 )
(3-139)
C Be k 2 t =
+ Const.
At time t = 0, the concentration of component B is CB = 0. Therefore, the constant Const. becomes Const. = −
k1C AO k ( 2 − k1 )
(3-140)
Therefore, Equation 3-139 becomes CB e k 2 t =
k1C AO e ( k 2 − k1 ) t kC − 1 AO k 2 − k1 k 2 − k1
(3-141)
and CB =
k1C AO e − k1t k1C AO e − k 2 t − k 2 − k1 k 2 − k1
(3-142)
The final concentration of B is: CB =
(
k1C AO − k1t e − e−k2t k 2 − k1
)
(3-143)
Reaction Rate Expression
143
To obtain the maximum concentration of B, differentiate Equation 3-143 with respect to time t, which gives
{
dC B k1C AO = − k1e − k1t + k 2 e − k 2 t dt k 2 − k1
}
(3-144)
The values of k1 and k2 govern the location and maximum concentration of B, and this occurs at dCB/dt = 0, t = tmax. Equation 3-144 becomes: k12 C AO e − k1t k k C e−k2t + 1 2 AO k 2 − k1 k 2 − k1
0=−
k12 C AO e − k1t k k C e−k2t = 1 2 AO k 2 − k1 k 2 − k1 e ( k 2 − k1 ) t max =
(3-145)
k2 k1
t max ( k 2 − k1 ) = ln
(3-146)
k2 k1
The maximum concentration of B occurs at
t max
k ln 2 k1 = k 2 − k1
(3-147)
At tmax k 2 e − t max k 2 = k1e − t max k1
(3-148)
Substituting for e − k1t in Equation 3-147 gives C B max C AO
=
{
}
1 k e − k 2 t max − k1e − k 2 t max = e − k 2 t max ( k 2 − k1 ) 2
(3-149)
144
Modeling of Chemical Kinetics and Reactor Design
Substituting Equation 3-147 into Equation 3-149 gives C B max
=
C AO
ln ( k 2 k 1 ) −k2 k −k e 2 1
(3-150)
Taking the natural logarithm gives
ln
C B max C AO
k2 k2 = − ln k 2 − k1 k1
(3-151)
Treating k2/(k 2 – k 1) as an exponent and removing the natural logarithm gives
C B max C AO
k2
k k 2 − k1 = 1 k2
(3-152)
This shows that C B max /C AO depends only on k1 and k2, and k2 can be evaluated from C B max /C AO at tmax. From stoichiometry: k
k
2 A 1 → B →C
Amount at time t = 0 Amount at time t = t
A
B
C
CAO CA
0 CB
0 CC
and from stiochiometry, (CAO – CA) = (CB + CC). That is, CC = (CAO – CA) – CB. The concentration of C in terms of CAO, k1, and k2 are:
k1 − k 1 t CC = 1 − e − k1t − − e−k2t e C AO k 2 − k1
(
k1 k2 = 1 + e−k2t − e − k 1t k 2 − k1 k 2 − k1
) (3-153)
Reaction Rate Expression
145
The concentrations of components A, B, and C vary with time. The concentration profiles of A, B, and C in a batch system using the differential Equations 3-127, 3-128, and 3-129 and velocity constants k1 and k2, and employing the Runge-Kutta fourth order numerical method are reviewed in Chapter 5. Important features of consecutive reactions occur in substitution processes. For example CH4 + Cl2 = CH3Cl + HCl and CH3Cl + Cl2 = CH2Cl2 + HCl, and so forth. They also occur frequently in oxidation processes, where the desired product may further oxidize to give an undesired product. An example is the oxidation of methanol, where the desired formaldehyde is readily degraded to carbon dioxide: CH3OH → HCHO → CO2. The formation of resins, tarry matter by consecutive reaction, is prevalent in organic reactions. Figure 3-13a shows the time variations in the concentrations of A, B, and C as given by these equations. The concentration of A falls exponentially, while B goes through a maximum. Since the formation rate of C is proportional to the concentration of B, this rate is initially zero and is a maximum when B reaches its maximum value. Kinetic Equations 3-143 and 3-153 are obeyed by nucleides undergoing radioactive decay, where the rate constant k1 is large and k2 is small. The reactant A is converted rapidly into the intermediate B, which slowly forms C. Figure 3-13b shows plots of the exponentials e − k1t and e − k 2 t and of their difference. Since k2 is small, the exponential −k t e − k 2 t shows a slow decay while e 1 shows a rapid decline. The −k2t − k 1t −e is shown by the dashed line in Figure 3difference of e 13b. The concentration of B is (Equation 3-143) equal to this difference multiplied by CAO (since k1 k k2). Therefore, the concentration of B rapidly rises to the value of CAO and then slowly declines. The rise in concentration C then approximately follows the simple first-order law. Conversely, when k1 is small and k2 is large (k2 k k1), the concentration of B is given by Equation 3-143:
CB =
(
k1C AO − k1t e − e−k2t k2
)
(3-154)
At t = 0, CB = 0, but after a short time, relative to the duration of the reaction, the difference e − k1t − e − k 2 t reaches the value of unity. The concentration of B is then CAOk1/k2, which is much less than CAO. After this short induction period, the concentration of B remains almost
146
Modeling of Chemical Kinetics and Reactor Design
Figure 3-13. (a) Variations in the concentrations of A, B, and C for a reaction k1 2 → B k → C . (b) Variations with time of occurring by the mechanism A the exponentials when k 1 k k 2. (c) Variations of the exponentials when k2 k k1.
constant, so that generally dC B /dt = 0, the basis of the steadystate treatment.
FIRST ORDER REVERSIBLE REACTIONS Consider the reaction A volume batch system is:
k1
[ B. k 2
The rate equation for a constant
Reaction Rate Expression
(− rA ) =
−
dC A = k1C A − k 2 C B dt
147
(3-155)
From stoichiometry:
Amount at time t = 0 Amount at time t = t Amounts that have reacted
A
B
CAO CA CAO – CA
CBO CB CB – CBO
and the concentration of B is CB = (CAO – CA) + CBO
(3-156)
Substituting Equation 3-156 into Equation 3-155, rearranging and integrating between the limits gives: CA
∫
t
−
C AO
−
CA
∫
C AO
−
dC A = ∫ dt k1C A − k 2 (C AO − C A ) + C BO 0
{
}
(3-157)
t
dC A = dt ( k1 + k 2 ) C A − k 2 (C AO − C BO ) ∫0 CA
1 ( k1 + k 2 ) C ∫
AO
(3-158) t
CA
dC A = ∫ dt k2 0 − (C AO − C BO ) k1 + k 2
(3-159)
where k2 α= (C AO − C BO ) k1 + k 2
(3-160)
Substituting Equation 3-160 into Equation 3-159 becomes
−
1 k1 + k 2
CA
∫
C AO
dC A = CA − α
t
∫ dt 0
(3-161)
148
Modeling of Chemical Kinetics and Reactor Design
Integrating Equation 3-161 between the boundary conditions t = 0, CA = CAO and t = t, CA = CA gives −
1 C ln [C A − α ]C A = t AO k1 + k 2
(3-162)
That is:
−
[
]
1 ln (C A − α ) − ln (C AO − α ) = t k1 + k 2
(3-163)
Substituting Equation 3-160 into Equation 3-163 gives
k (C − C BO ) − ln C A − 2 AO k1 + k 2 k (C − C BO ) − ln C AO − 2 AO = ( k 1 + k 2 )t k1 + k 2 ( k + k )C − k 2 C AO + k 2 C BO − ln 1 2 A ( k1 + k 2 )
(3-164)
(3-165)
k C + k 2 C AO − k 2 C AO + k 2 C BO − ln 1 AO = ( k 1 + k 2 )t ( k1 + k 2 )
{ [
]
− ln ( k1 + k 2 )C A − k 2 (C AO − C BO )
}
− ln [ k1C AO + k 2 C BO ] = ( k1 + k 2 )t
(3-166)
or k1 k − ln 2
+ 1 C A − (C AO − C BO ) = ( k 1 + k 2 )t k1 C AO + C BO k2
(3-167)
Reaction Rate Expression
149
At equilibrium with concentrations of A and B as CAe, CBe, respectively, then k1CAe = k2CBe. Since dCA/dt = 0 at equilibrium C k1 = K = Be k2 C Ae
(3-168)
Substituting Equation 3-168 into Equation 3-167 gives C Be + 1 • C A − (C AO − C BO ) C − ln Ae = ( k 1 + k 2 )t C Be • C AO + C BO C Ae
(3-169)
A plot of
(C C + 1) • C A − (C AO − C Bo ) − ln Be Ae (C Be C Ae ) • C AO + C BO
(
)
versus time t gives a straight line with the slope (k1 + k2). From the slope and the equilibrium constant K, k1 and k2 can be determined. Figure 3-14 shows a plot of the reversible first order reaction.
Figure 3-14. First order reversible reaction.
150
Modeling of Chemical Kinetics and Reactor Design
Examples of first-order reversible reactions are gas phase cis-trans isomerization, isomerizations in various types of hydrocarbon systems, and the racemization of α and β glucoses. An example of a catalytic reaction is the ortho-para hydrogen conversion on a nickel catalyst.
SECOND ORDER REVERSIBLE REACTIONS Bimolecular-type second order reactions are: k1
A+B[C+D
(3-170)
k2
k1
2A[ C + D
(3-171)
k2
2A
k1
[ 2C k
(3-172)
2
k1
A + B [ 2C
(3-173)
k2
With the restrictions that CAO = CBO and CCO = CDO = 0 in Equation 3-170, the rate equation for a constant volume batch system becomes
(− rA ) = −
dC A dX A = C AO = k1C 2A − k 2 C C2 dt dt
= k1C 2AO (1 − X A ) − 2
k2 2 XA k1
(3-174)
(3-175)
where the fractional conversion XA = 0 at t = 0. At equilibrium, dXA/dt = 0 and the final solution is:
X − (2 X Ae − 1) X A 1 ln Ae − 1 t = 2 k1C AO X Ae − X A X Ae
(3-176)
Reaction Rate Expression
151
All other reversible second-order rate equations have the same solution with the boundary conditions assumed in Equation 3-176. Table 3-4 gives solutions for some reversible reactions.
GENERAL REVERSIBLE REACTIONS Integrating the rate equation is often difficult for orders greater than 1 or 2. Therefore, the differential method of analysis is used to search the form of the rate equation. If a complex equation of the type below fits the data, the rate equation is:
Table 3-4 Rate equations for opposing reactions Stoichiometric equation
Rate equationa Differential form
A[Z
dx = k 1 (a 0 − x) − k −1x dt
A[Z
dx dt
2A [ Z
dx dt
A[2Z
dx dt
A[Y + Z
dx = k 1 (a 0 − x) − k −1x 2 dt
A + B[ Z
dx = k 1 (a 0 − x) 2 − k −1x dt
A + B[ Y + Z
dx = k 1 (a 0 − x) 2 − k −1x 2 dt
2A [ Y + Z
x dx = k 1 (a 0 − x ) 2 − k 1 2 dt
a
Integrated form
= k 1 (a 0 − x) − k −1 ( x + x 0 ) x = k 1 (a 0 − x) − k −1 2 x = k1 a 0 − − k −1x 2
xe xe ln = k 1t a 0 x e − x
a x + x(a 0 − x e ) xe ln 0 e = k 1t 2a 0 − x e a 0 (x e − x) x e (a 20 − xx e ) xe ln = k 1t a 20 − x 2e a 20 ( x e − x)
2
x(a 0 − 2 x e ) + a 0 x e xe ln = k 1t a 0 (x e − x) 2 a 0 (a 0 − x e )
In all cases x is the amount of A consumed per unit volume. The concentration of B is taken to be the same as that of A. (Source: Laidler, K. J., 1987. Chemical Kinetics, 3rd ed., Harper Collins Publishers.)
152
Modeling of Chemical Kinetics and Reactor Design
(− rA ) = −
dC A CA = k1 dt (1 + k 2C A )
(3-177)
Taking the reciprocals of Equation 3-177 gives k 1 + k 2CA 1 1 = = + 2 (− rA ) k1C A k1C A k1
(3-178)
Plotting 1/(–rA) versus 1/CA would give a straight line with the slope equal to 1/k 1 and an intercept of k 2/k 1. Another analysis method involves multiplying each side of Equation 3-178 by k1/k2 and solving for (–rA) to give
(− r ) k (− rA ) = k 1 − k CA 2
2
(3-179)
A
Plotting (–rA) versus (–rA)/CA gives a straight line with the slope equal to –1/k2 and the intercept equal to k1/k2.
SIMULTANEOUS IRREVERSIBLE SIDE REACTION Consider the chemical reactions k1
A k2
→B
↓
C in which the reactions are first order, the initial concentration of A is C AO, and both the concentrations of B and C are zero. The rate equations representing the reactions for a constant volume batch system are: For component A ( − rA ) = − For component B ( + rB ) =
dC A = ( k1 + k 2 )C A dt
dC B = k1C A dt
(3-180)
(3-181)
Reaction Rate Expression
For component C ( + rC ) =
dC C = k 2C A dt
153
(3-182)
Rearranging and integrating Equation 3-180 between the limits gives −
CA
∫
C AO
− ln
dC A = CA
t
∫ (k1 + k 2 )dt
(3-183)
0
CA = ( k 1 + k 2 )t C AO
(3-184)
The solution for the concentration of A is
C A = C AO e − ( k1 + k 2 ) t
(3-185)
Substituting Equation 3-185 into Equation 3-181, rearranging and integrating gives CB
∫ 0
t
C AO
dC B = k1 ∫ dt e −( k1 + k 2 )t
(3-186)
0
Further rearrangement of Equation 3-186 gives 1 C AO
CB
∫ 0
t
dC B = k1 ∫ e − ( k1 + k 2 ) t + Constant
CB k1 =− e − ( k1 + k 2 ) t + Constant C AO ( k1 + k 2 ) At t = 0, CB = 0
Constant =
(3-187)
0
k1 ( k1 + k 2 )
The solution for concentration of B is
(3-188)
154
Modeling of Chemical Kinetics and Reactor Design
CB =
{
C AO k1 1 − e −( k1 + k 2 )t ( k1 + k 2 )
}
(3-189)
Correspondingly, the solution for the concentration of C is CC =
{
C AO k 2 1 − e −( k1 + k 2 )t ( k1 + k 2 )
}
(3-190)
Concentration profiles can be developed with time using the differential Equations 3-180, 3-181, and 3-182, respectively, with the Runge-Kutta fourth order method at known values of k1 and k2 for a batch system.
PSEUDO-ORDER REACTION The results of the types of reaction being considered show that the treatment of kinetic data becomes rapidly more complex as the reaction order increases. In cases where the reaction conditions are such that the concentrations of one or more of the species occurring in the rate equation remain constant, these terms may be included in the rate constant k. The reactions can be attributed to lower order reactions. These types of reactions can be defined as pseudo-nth order, where n is the sum of the exponents of those concentrations that change during the reaction. An example of this type of reaction is in catalytic reaction, where the catalyst concentration remains constant during the reactions. A kinetic study of a reaction can be simplified by running the reaction with one or more of the components in large excess, so that the concentration remains effectively constant. Mc Tigue and Sime [2] consider the oxidation of aliphatic aldehydes such that ethanal with bromine in aqueous solution follows second-order kinetics: Br2 + CH3CHO + H2O → CH3COOH + 2H+ + 2Br–
(3-191)
The rate equation of the reaction for a constant volume batch system is
−
dC Br2 dt
= k 2 C CH 3CHO C Br2
(3-192)
Reaction Rate Expression
155
If there is excessively large aldehyde, its concentration remains constant and the reaction can be referred to as pseudo-first order kinetics. Equation 3-192 can be rewritten as
−
dC Br2 dt
= k1C Br2
(3-193)
where k1 = k 2 C CH 3CHO
(3-194)
The second order rate constant k2 is k 2 = k1 C CH 3CHO , and can be determined by measuring k1 at known aldehyde concentrations. The use of excess reagent concentrations has important practical consequences where physical methods, such as light absorption or conductance, are used to monitor reactions.
PRACTICAL MEASUREMENTS OF REACTION RATES Many techniques have been employed in kinetic studies to determine reaction rate constants and reaction orders from either reactant or product concentrations at known times. The most desirable analytical methods allow continuous and rapid measurement of the concentration of a particular component. Any of the methods used to monitor the course of reaction must satisfy the following criteria: • The method should not interfere with the system by affecting the kinetic processes occurring during the investigation. • It must give an exact measure of the extent of the reaction. • The measurement should be representative of the system at the time it is made or at the time the sample analyzed was taken. Analyses of kinetic data are based on identifying the constants of a rate equation involving the law of mass action and some transfer phenomena. The law of mass action is expressed in terms of concentrations of the species. Therefore, the chemical composition is required as a function of time. Laboratory techniques are used to determine the chemical composition using an instrument that is suitably calibrated to give the required data. The techniques used are classified into two categories, namely chemical and physical methods.
156
Modeling of Chemical Kinetics and Reactor Design
Chemical methods involve removing a portion of the reacting system, quenching of the reaction, inhibition of the reaction that occurs within the sample, and direct determination of concentration using standard analytical techniques—a spectroscopic method. These methods provide absolute values of the concentration of the various species that are present in the reaction mixture. However, it is difficult to automate chemical methods, as the sampling procedure does not provide a continuous record of the reaction progress. They are also not applicable to very fast reaction techniques. Physical methods involve measuring a physical property of the system as the reaction progresses. It is often possible to obtain a continuous record of the values of the property being measured, which can be transformed into a continuous record of reactant and product concentrations. Examples of physical methods that vary linearly with concentrations include conductance (ionic reagents), absorption of visible or ultraviolet light, optical density, the total pressure of gaseous systems under nearly ideal conditions, and the rotations of polarized light. An essential feature of physical methods involves continuous, rapid response measurement without the need for sampling. Physical techniques can be used to investigate first order reactions because the absolute concentrations of the reactants or products are not required. Dixon et. al [3] studied the base hydrolysis of cobalt complex, [Co(NH3)5L]3+, where L = (CH3)2SO, (NH2)2C = O, (CH3)O3P = O in glycine buffers.
[Co(NH ) L]
3+
[
OH → Co( NH 3 )5 OH −
3 5
]
2+
+L
(3-195)
The rate equation is:
−
[
d Co( NH 3 )5 L dt
]
3+
[
= k Co( NH 3 )5 L
]
3+
(3-196)
The release of dimethyl sulfoxide is accompanied by an increase in absorbance (D) at 325 nm. The absorbance D is defined as log(Io/I), where Io and I are the intensities of the incident and transmitted light, respectively. Figure 3-15 illustrates the relationship between concentration and absorbance changes for the hydrolysis of the cobalt
Reaction Rate Expression
157
Figure 3-15. Relationship between concentration and absorbance changes for the hydrolysis of [Co(NH3)5L]3+.
complex. The values of the absorbance during the reaction are related to the concentration of the cobalt complex and is represented by C as follows: CO α
C α
(D ∞ − D O ) ; ( D ∞ − D) ;
C O = Const. (D ∞ − D O ) C = Const. (D ∞ − D)
(3-197)
158
Modeling of Chemical Kinetics and Reactor Design
where Const. is a proportionality constant related to the absorption coefficients of the reactants and products at 325 nm. Substituting Equation 3-197 into the integrated first order reaction Equation 3-33 gives the corresponding equations expressed in terms of the solution absorbance: ln (D∞ – D) = –kt + ln (D∞ –DO)
(3-198)
D∞ – D = (D∞ – DO)e–kt
(3-199)
or
Equation 3-199 infers that the absorbance approaches the value at the end of the reaction (infinity value) with the same rate constant k as that for the reaction expressed in terms of the reactant concentration. The required rate constant can be determined from the slope of a plot of ln (D∞ – DO) versus time. The same equations can be written for reactions monitored in terms of optical rotation or conductance. In the case of a second order reaction, an example is the alkaline hydrolysis of an ester as represented by the following equation: 2 CH 3COOC 2 H 5 + OH − → CH 3COOH + C 2 H 5OH
k
(3-200)
The rate equation for a constant volume batch system is −
dC CH 3COOC 2 H 5 dt
= k 2 C CH 3COOC 2 H 5 C OH −
(3-201)
Substituting Equation 3-197 into Equation 3-53 gives the following equation for the change in absorbance at the selected wavelength. 1 1 − = Const. k 2 t ( D ∞ − D) ( D ∞ − D O )
(3-202)
A plot of 1/(D ∞ – D) versus time t is linear with the slope = Const.k2. The rate constant k2 is determined if the proportionality constant Const. is known, between the absorbance change and the extent of the reaction. The proportionality constant can either be determined by calibrating the system or, more accurately, by studying the reaction under pseudo-first order conditions.
Reaction Rate Expression
159
Another useful technique in kinetic studies is the measurement of the total pressure in an isothermal constant volume system. This method is employed to follow the course of homogeneous gas phase reactions that involve a change in the total number of gaseous molecules present in the reaction system. An example is the hydrogenation of an alkene over a catalyst (e.g., platinum, palladium, or nickel catalyst) to yield an alkane: C n H 2 n + H 2 → C n H 2 n + 2 Pt, Pd, or Ni catalyst
(3-203)
Nickel is the least active of these catalysts and requires an elevated temperature and pressure, whereas platinum and palladium function adequately at ordinary temperatures and pressures. An example is butylene to butane: C4H8 + H2 → C4H10
(3-204)
In gaseous reactions, the composition term in the rate equation is often expressed as the partial pressure of the reacting species. These pressures are then transformed to concentration. Consider the reaction A → products. The rate equation is:
(− rA ) = k p p An
n = kC A
(3-205)
where
(− rA ) = kp =
mol m3 • s
mol m • Pa n • s 3
mol l•s mol l • atm n • s
n pA = Pa n
(atm n )
mol 1− n k = 3 s −1 m
mol l•s
1− n
s −1
For ideal gases, the partial pressure is expressed as:
160
Modeling of Chemical Kinetics and Reactor Design
pA = CART
(3-206)
where p A = Pascal, Pa
CA =
(atm) mol l
mol m3
R = 8.314
m 3 Pa l • atm or 0.082 • mol • K mol • K
Caution must be exercised when the rate equations with gas phase reactions are expressed in terms of the partial pressure as compared to concentration. This is because each rate gives different activation energy for the same data and for the same reaction. Levenspiel [4] suggests that the difference can be ignored for reactions with reasonably high activation energies as the amount is only a few kJ. Pressure measurement devices such as a manometer are used without disturbing the system being monitored. Another type of reacting system that can be monitored involves one of the products being quantitatively removed by a solid or liquid reagent that does not affect the reaction. An example is the removal of an acid formed by reactions in the gas phase using hydroxide solutions. From the reaction stoichiometry and measurements of the total pressure as a function of time, it is possible to determine the extent of the reaction and the partial pressure or concentrations of the reactant and product species at the time of measurement. Consider the following gaseous reaction aA + bB → cC + dD. Pressure and concentration are related, and for a constant volume reactor with changing number of moles during reaction, the total pressure (π) changes with time, t. For an ideal gas, with any reactant A or B, the partial pressure is expressed as:
p A = C A RT = p AO +
a (π O − π) ∆n
(3-207)
where ∆n = (c + d) – (a + b)
(3-208)
Reaction Rate Expression
161
For any product C or D, the partial pressure is expressed as: p C = C C RT = p CO −
c (π O − π) ∆n
(3-209)
For an ideal gas at both constant temperature and pressure, but with changing number of moles during reaction, Levenspiel relates that V = VO(1 + εAXA)
(3-210)
where εA =
Vall A reacted − Vno reaction Vno reaction
=
VX A =1 − VX A = 0 VX A = 0
(3-211)
Levenspiel considers the cases where the relationship between concentration and conversion of reacting specie is not obvious, but depends on a number of factors. CASE 1: CONSTANT DENSITY SYSTEMS This case includes most liquid reactions and also those gas reactions that operate at both constant temperature and pressure with no change in the number of moles during reaction. The relationship between concentration CA and fractional conversion XA is as follows:
XA =1−
CA dC and dX A = − A C AO C AO
CA = 1 − X A and dC A = − C AO dX A C AO
(3-212)
where εA = 0. The changes in B and C to A are C AO − C A C BO − C B C C − C CO = = a b c or
(3-213)
162
Modeling of Chemical Kinetics and Reactor Design
C AO X A a
=
C BO X B b
(3-214)
CASE 2: CHANGING DENSITY GASES This case involves constant temperature T and total pressure π. In this case, the density changes since the number of moles change during the reaction, and the volume of a fluid element changes linearly with conversion or V = VO(1 + εAXA). The relationship between CA and XA is as follows:
XA =
− C AO (1 + ε A ) dC A C AO − C A and dX A = C AO + ε A C A (1 + ε A C A )2
−1 + ε A yA C 1 − XA dC A dX A = A = = and y AO C AO 1 + ε A X A C AO (1 + ε A X A )2
(3-215)
for εA ≠ 0, where yA = mole fraction of component A. The changes between the reactants are: εAX A = εB XB
(3-216)
aε A bε B = C AO C BO
(3-217)
and for the products and inerts:
yC C (c a ) X A + CCO C AO = C = 1 + εAXA y AO C AO
(3-218)
yI C 1 = I = y IO C IO 1 + ε A X A
(3-219)
CASE 3: GASES WITH VARYING DENSITY, TEMPERATURE, AND TOTAL PRESSURE Consider the following reaction: aA + bB → cC; a + b ≠ c. For an ideal gas behavior with reactant A as the key component, the relationship between concentration CA, CAB, CC, and XA are as follows:
Reaction Rate Expression
CA T πO C AO TO π 1 − X A TO π CA = XA = or C AO 1 + ε A X A Tπ O C T πO 1 + εA A C AO TO π
163
1−
(3-220)
C BO T πO C BO C b − B − XA TO π C C AO Tπ C B C AO a X A = AO or = (3-221) C AO 1 + ε A X A Tπ O C B Tπ O b + εA a C AO TO π C C Tπ O C CO − C AO TO π C AO XA = C Tπ c − εA C O a C AO TO π
or
CC C AO
C CO c + XA TO π C AO a = (3-222) 1 + ε A X A Tπ O
where εA is evaluated from stoichiometry at constant temperature T and total pressure π. For a high-pressure non-ideal gas behavior, the term (TOπ/TπO) is replaced by (ZOTOπ/ZTπO), where Z is the compressiblity factor. To change to another key reactant B, then C AO X A C BO X B aε A bε B = and = C AO C BO a b
(3-223)
For liquids or isothermal gases with no change in pressure and density, εA → 0 and (TOπ/TπO) → 1. Other forms of physical methods include optical measurements that can be used to monitor the course of various reactions such as colorimetry, fluorescence, optical rotation, and refractive indices. Various spectroscopic techniques have been employed in kinetic studies. The absorption of a reacting system of electromagnetic radiation (light, microwaves) is a designated property of the system composition and dimensions. Among the various forms of spectroscopic methods that can be used in kinetic studies are nuclear magnetic resonance, electron spin resonance spectroscopy, visible ultraviolet, and infrared. Figure 3-16 shows a flowchart that will help to
164
Modeling of Chemical Kinetics and Reactor Design
Figure 3-16. Interpretation of rate data. (Source: Curl, R. L., 1968. Unpublished notes, University of Michigan.)
determine the rate equation for isothermal batch reaction systems in which only one chemical reaction occurs. Level 1 in the chart indicates that when the reaction rate law is known, the integral method of analysis may be used after performing an experiment to evaluate the specific reaction rate. This procedure
Reaction Rate Expression
165
is useful when the reaction order and specific rate at one temperature are already known from previous experiments, and the specific reaction rate at some other temperature is sought. If the reaction rate constant k at two or more different temperatures is known, it is possible to determine the activation energy and the frequency factor. Level 2 involves the trial-and-error method. After trying zero, first, second, and finally third order, if none of these orders fit the data, another analysis method should be tried. When the reaction order is unknown, cannot be guessed, and the reaction is irreversible, proceed to level 4. If the reaction rate depends on only one species (e.g., isomerization or decomposition reactions), use the differential method that requires only one experiment, or the method of half-lives that requires many experiments, to determine the specific reaction rate and order. However, where certain constraints imposed by a given reaction prevent collating experimental data other than in the initial rate period, neither the differential nor the half-life method may be suitable. Examples include a solid-liquid reactions, where flaking or crumbling of the solid occurs, and certain autocatalytic and simultaneous reactions. In such instances, it is usually best to use the initial rate plot method given in level 5. In this technique, the initial rate is measured at various initial concentrations of the reacting species. The reaction order can be determined from a plot of the logarithm of the initial reaction rate, ln (–r AO), against the logarithm of the initial concentration, ln CAO. The two methods of analysis that require only one experiment to determine the reaction order and the specific rate constant are the integral method (level 2) and the differential method. If the reaction rate depends on more than one species, use the method of excess coupled either with the half-life method or the differential method. If the method of excess is not suitable, an initial rate plot may be constructed by varying the concentration of one reactant while the concentrations of the others are held constant. This process is repeated until the orders of reaction of each species and the specific reaction rate are evaluated. At level 5, the least-squares analysis can be employed. Figure 3-16 is helpful in the logical planning of a series of kinetic experiments to determine reaction orders and specific rate constants. However, it is important to remember the main goals and design of the entire experimental analysis. Table 3-5 gives methods used to determine direct or indirect measurements of a species concentration. (text continued on page 168)
166
Modeling of Chemical Kinetics and Reactor Design
Table 3-5 Methods of analysis
Applications
References
a. Total pressure a. change
Gas phase reactions performed under constant volume in which there is a change in the total number of moles in the gas phase.
J. Chem. Ed., 46 (1969), 684, A. P. Frost and R. G. Pearson, Kinetics and Mechanism, 2nd ed. (New York: John Wiley and Sons, 1968), Chap. 3.
b. Temperature b. change
Endothermic or exothermic reactions that are performed adiabatically.
Chem. Engr. Sci., 21 (1966), 397.
c. Volume change
(1) Gas phase reactions performed under constant pressure and involving a change in the total number of moles.
O. Levenspiel, Chemical Reaction Engineering, 2nd ed. p. 91, (New York: John Wiley and Sons, 1972).
(2) Solid or liquid phase reactions in which there is a density change on reaction.
J. Am. Chem. Soc., 70 (1948), 639. I.E.C. Process Design & Development, 8, No. 1, (1969), 120.
1. Physical methods
2. Optical methods a. Absorption a. spectrometry
Transitions within molecules, which can be studies by the selective absorption of electromagnetic radiation. Transitions between electronic levels are found in the UV and visible regions; those between vibrational levels, within the same electronic level are in the IR region
(1) Visible
Reactions involving one (or at most two) colored compound(s).
(2) Ultraviolet
The determination of organic compounds, expecially aromatic and heterocyclic substances or compounds with conjugated bonds.
J. Chem. Ed. 49, No. 8 (1972), 539. I.E.C. Process Design & Development, 8, No. 1, (1969), 120.
Reaction Rate Expression
167
(3) Infrared
Organic compounds only.
I.E.C. Product Research and Development, 7, No. 1, (1968), 12.
(4) Atomic absorption
Metallic ions.
K. Lund, H. S. Fogler and C. C. McCune, Chem. Engrs. Sci., 28, (1973), 691.
b. Polarimetry
Liquid phase reactions involving optically active species.
Nature 175 (London: 1955), 593.
c. Refractometry
Reaction in which there is a measurable difference between the refractive index of the reactants and that of the products.
3. Electrochemical methods a. Potentiometry
Used in the measurement of the J. Am. Chem. Soc., 68 (1946), Ibid, 69, (1947), potentials of nonpolarized 1325. electrodes under conditions of zero current. Seldom used in organic reactions.
b. Voltammetry b. and b. polarography
Used for dilute electrolytic solutions. Not applicable to reactions that are catalyzed by mercury.
J. Am. Chem. Soc., 71, (1949), 3731.
Reactions involving a change in the number of kind of ions present, thereby changing the electrical conductivity. Suitable for both organic and inorganic reactions.
J. Chem. Soc., 97, (London: 1910), 732 Frost & Pearson, Kinetics and Mechanism, Chap. 3.
Used primarily for compounds containing hydrogen.
J. Chem. Ed., 49, No. 8, (1972), 560. Pople, Schneider & Bernstein, High-Resolution Nuclear Magnetic Resonance, (New York: McGraw-Hill, 1959).
c. Conductimetry
4. Nuclear methods a. Magnetic a. resonance a. spectrometry (1) Nuclear magnetic resonance
168
Modeling of Chemical Kinetics and Reactor Design
Table 3-5 (continued) Methods of analysis (2) Electron spin resonance
Applications Used in free radical studies and for estimation of trace amounts of paramagnetic ions.
b. Mass b. spectrometry
c. Nuclear c. radiation c. (radioisotopes)
References J. Chem. Phy., 46, No. 2, (1967), 490. Ibid. 48, No. 10, (1968), 4405. Pro. Royal Soc., A199, (London: 1949), 394. I.E.C. Process Design & Development, 8, No. 4, (1969), 450, 456.
Elucidation of reaction mechanisms.
Trans. Faraday Soc., 30, (1934), 508.
Gas phase reactions; also liquid phase reactions involving only volatile substances.
I.E.C. Product Research and Development, 8, No. 3, (1969), 319. Ibid. 10, No. 2 (1971), 138.
5. Methods of interphase separations a. Gas-liquid a. chromatography
Source: Fogler, H. S., 1974. The Elements of Chemical Kinetics and Reactor Calculations— A Self-Paced Approach, Prentice-Hall, Inc., Englewood Cliffs, NJ (text continued from page 165)
Most of the references listed refer to a specific chemical kinetics experiment in which the corresponding method analysis was used to obtain the rate data. DETERMINING REACTION RATE DATA The principal techniques used to determine reaction rate functions from the experimental data are differential and integral methods. Differential Method This method is based on differentiating the concentration versus time data in order to obtain the actual rate of reaction to be tested. All the terms in the equation including the derivative (dCi/dt) are determined, and the goodness of fit are tested with the experimental
Reaction Rate Expression
169
data. The following procedures are used to determine the rate constant k and the concentration dependence of the rate equation f(Ci). 1. Set a hypothesis as to the form of the concentration dependent of the rate function f(Ci). This can be of the form
(− rA ) =
−
dC A = k f (C i ) dt
(3-224)
2. From the experimental data of concentration versus time, determine the reaction rate at various times. 3. Draw a smooth curve through these data. 4. Determine the slope of this curve at selected values of the concentration. The slopes are the rates of reaction at these compositions. 5. Calculate f(Ci) for each composition. 6. Prepare a plot of reaction rate (–dCA/dt) versus f(Ci). If the plot is linear and passes through the origin, the rate equation is consistent with the data, otherwise another equation should be tested. Figure 3-17 shows a schematic of the differential method. Integral Method This method estimates the reaction order based on the reaction stoichiometry and assumptions concerning its mechanism. The assumed rate equation is then integrated to obtain a relation between the composition and time. The following procedures are used for determining the rate equations: 1. Set a hypothesis as to the mathematical form of the reaction rate function. In a constant volume system, the rate equation for the disappearance of reactant A is
(− rA ) = −
dC A = k f (C A ) dt
(3-225)
2. Separate the variables and integrate Equation 3-225 to give −
CA
∫
C AO
t
dC A = k ∫ dt f (C A ) 0
(3-226)
170
Modeling of Chemical Kinetics and Reactor Design
Figure 3-17. Schematics of the differential method for data analysis.
Reaction Rate Expression
171
3. Plot the calculated values as shown in Figure 3-18 to give a straight line of slope k. 4. From experimentally determined values of the integral of Equation 3-226, plot these at corresponding times as shown in Figure 3-18. 5. If the data yield a satisfactory straight line passing through the origin, then the reaction rate equation (assumed in step 1) is said to be consistent with the experimental data. The slope of the line is equal to the reaction rate constant k. However, if the data do not fall on a satisfactory straight line, return to step 1 and try another rate equation.
REGRESSION ANALYSES LINEAR REGRESSION If the rate law depends on the concentration of more than one component, and it is not possible to use the method of one component being in excess, a linearized least squares method can be used. The purpose of regression analysis is to determine a functional relationship between the dependent variable (e.g., the reaction rate) and the various independent variables (e.g., the concentrations).
Figure 3-18. Test of reaction rate data using the integral method.
172
Modeling of Chemical Kinetics and Reactor Design
Consider a mole balance on a constant volume batch reactor represented by
−
dC A = kC aA C Bb dt
(3-227)
Using the method of initial rates gives
− dC A = − r b ( A )O = kCaAOC BO dt O
(3-228)
Taking the logarithms of both sides of Equation 3-228 gives dC A ln − = ln k + a ln C AO + b ln C BO dt
(3-229)
This can be represented in the form Y = C 0 + C 1X 1 + C2 X2
(3-230)
where Y = ln (–dCA/dt), CO = ln k, X1 = ln CAO, X2 = ln CBO, C1 = a, and C2 = b. If N experimental runs are performed, then for the ith run, Equation 3-230 becomes Yi = CO + C1X1,i + C2X2,i
(3-231)
where X1i = ln CAOi, with CAOi being the initial concentration of A for the ith run. Solving for the unknowns CO, C1, and C2 for N experimental runs, i = 1, 2, 3 . . . N, gives N
N
N
i =1
i =1
i =1
∑ Yi = N CO + C1 ∑ X1i + C2 ∑ X 2 i
(3-232)
N
N
N
N
i =1
i =1
i =1
i =1
N
N
N
N
i =1
i =1
i =1
i =1
∑ X1i Yi = CO ∑ X1i + C1 ∑ X12i + C2 ∑ X1i X 2 i ∑ X 2 i Yi = CO ∑ X 2 i + C1 ∑ X1i X 2 i + C2 ∑ X 22 i
(3-233)
(3-234)
Reaction Rate Expression
173
Equations 3-232, 3-233, and 3-234 can be solved simultaneously to determine the unknowns CO, C1, and C2, which are the rate constant k, and the orders (a and b) of the reaction respectively. This type of problem is best expedited using a computer program. Appendix A reviews the multiple regression that is being employed to determine the rate constant k and the orders (a and b) of the reaction. The computer program (PROG3) on the CD-ROM determines the rate constant k and the orders (a and b) of the reaction. Other parameters such as the reaction order, frequency factor kO, and activation energy Ea can be determined using regression analysis. NONLINEAR ANALYSIS Another method for determining rate law parameters is to employ a search for those parameter values that minimize the sum of the squared difference of measured reaction rate and the calculated reaction rate. In performing N experiments, the parameter values can be determined (e.g., Ea, CO, C1, and C2) that minimize the quantity:
s2 σ = = N–K 2
where σ2 s2 N K rim ric
= = = = = =
N
∑ i =1
(rim
− ric ) N − K −1
2
(3-235)
variance Σ (rim – ric)2 number of runs number of parameters to be determined measured reaction rate for run i calculated reaction rate for run i
Nonlinear least squares curve fitting using the Microsoft Solver is reviewed in Appendix B.
WEIGHTED LEAST SQUARES ANALYSIS A weighted least-squares analysis is used for a better estimate of rate law parameters where the variance is not constant throughout the range of measured variables. If the error in measurement is corrected, then the relative error in the dependent variable will increase as the independent variable increases or decreases. Consider a first order reaction with the final concentration expressed by CA = CAOe–kt. If the error in concentration measurement is 0.01CAO,
174
Modeling of Chemical Kinetics and Reactor Design
the relative error in the concentration measurement [0.01CAO/CA(t)] increases with time. It is possible to minimize the sum of N measurements by: N
σ 2 = ∑ Wi [ y i (exp tl) − y i (calc)]
2
(3-236)
i =1
where Wi is the weighing factor. The weighted least-squares analysis is important for estimating parameter involving exponents. Examples are the concentration time data for an irreversible first order reaction expressed by CA = CAOe–kt, and the reaction rate-temperature data expressed by ( − rA ) = k O C A e − E a RT. These equations are of the form Y = Ae–BX
(3-237)
where Y = CA or (–rA) and X = t or 1/T, respectively. Linearizing Equation 3-237 gives ln Y = ln A – BX
(3-238)
It is also possible to determine A and B that minimize the weighted sum of squares. The weighting function is the square of the independent variable, and the function to be minimized is N
σ 2 = ∑ y 2i [ln y i (exp tl) − ln y i (calc)]
2
i =1
(3-239)
VALIDITY OF LEAST SQUARES FITTING The validity of least squares model fitting is dependent on four principal assumptions concerning the random error term ε, which is inherent in the use of least squares. The assumptions as illustrated by Bacon and Downie [6] are as follows: Assumption 1: The values of the operating variables are known exactly. In practice, this is interpreted to mean that any uncertainty associated with a value of an operating variable has much less effect on the response value than the uncertainty associated with a measured value of the response itself. Assumption 2: The form of the model is appropriate. Statistically, this is expressed as E(ε) = 0 for all data, where ε is the random error.
Reaction Rate Expression
175
Assumption 3: The variance of the random error term is constant over the ranges of the operating variables used to collect the data. When the variance of the random error term varies over the operating range, then either weighted least squares must be used or a transformation of the data must be made. However, this may be violated by certain transformations of the model. Assumption 4: There is no systematic association of the random error for any one data point with the random error for any other data point. Statistically this is expressed as: Correlation (εu, εv) = 0. For u, v = 1, 2, . . . n, u ≠ v, where εu = random error for experimental run number u εv = random error for experimental run number v
PROBLEMS AND ERRORS IN FITTING RATE MODELS Several methods are used to fit rate models, the two most common of which often give erroneous results. The first is the transformation of a proposed rate model to achieve a model form that is linear in the parameters. An example is the nonlinear model: r = kC aA C Bb
(3-240)
which can be transformed into linear form by taking logarithm of both sides ln r = ln k + a ln CA + b ln CB
(3-241)
Equation 3-241 is a linear model of the form Y = C O + C 1X1 + C 2X 2
(3-242)
where X1 = ln CA and X2 = ln CB. Another example of model transformation to achieve linearity is the change from the nonlinear rate equation
r=
k O k1C A 1 + k1C A + k 2 C B
to the equation
(3-243)
176
Modeling of Chemical Kinetics and Reactor Design
k2 C 1 1 1 1 = + • + • B r kO k O k1 C A k O k1 C A
(3-244)
which is of the linear form Y = C O + C 1X1 + C 2X 2
(3-245)
where X1 = 1/CA and X2 = CB/CA. The practice of transforming a nonlinear model into linear form can result in invalid estimates of the coefficients and consequent misinterpretation of the fitted model. The problem is associated with the assumption of a constant error variance (Assumption 3). If the measured rates r have a constant error variance, then the errors associated with ln r (Equation 3-241) or 1/r (Equation 3-244) will not have a constant error variance. The degree of violation will depend on the range of the measured reaction rate values. If the data contain both very small rates and very large rates, then the error variance will change appreciably over the data set and ordinary least squares estimates of the coefficients will give poor estimates. However, if the rate values are not spread over a large range, then model transformations of Equations 3-241 and 3-244 will not significantly distort the estimated coefficients. An illustration of the effects of linearizing model transformation of Equation 3-240 is given in Example 3-1. Generally, a model form is first proposed (i.e., a hypothesis that must be tested) using plots of the data. A simple plot can show obvious inadequacies in the model form and can suggest a better form. Alternatively, it can show excessive scatter in the data and warn against overconfidence in an adequate fit. The least squares estimates of the parameters are determined using a weighted or an optimization (i.e., trial-and-error) search procedure if required. This gives the best estimates if the assumptions are valid. Further testing the adequacy of the fitted model requires using both plots of the residuals and the sum of squares of the residuals. Finally, an estimate should be made of the precision of each parameter estimate by statistical analysis (e.g., 95% confidence intervals for the parameters). Often, one or more model forms in chemical reaction kinetics may fit the data. Although it is tempting to want to justify a specific model as the mechanism of the reaction, it is preferable to only infer that the model could be the mechanism. It is also desirable that the reaction mechanism taking place be understood in order to solve a problem in
Reaction Rate Expression
177
reactor design. This is because knowledge of the mechanism will make if possible to fit the experimental data to a theoretical rate expression, which will be more reliable than an empirical fit. Also, the mechanism may require some modifications and optimization for the final design. Example 3-1 3− The oxidation of Fe(CN ) to Fe(CN )6 by peroxidisulfate, S2 O82− , can be monitored spectrophotometrically by observing the increase in absorbance at 420 nm, D420 in a well-mixed batch system. Assume that the kinetic scheme is: 4− 6
Fe(CN )64 − + −
[
1 k2 S2 O82 − → Fe(CN )36 − + SO 24 − 2
]
[
][
d Fe(CN )64 − = k 2 Fe(CN )64 − S2 O82 − dt
]
Using pseudo-first order conditions with [S2 O82 − ] = 1.8 × 10 −2 M and [ Fe(CN )64 − ] = 6.5 × 10 −4 M , the following absorbances were recorded at 25°C: t/s D420
0 0.120
900 0.290
1,800 0.420
2,700 0.510
3,600 0.581
4,500 0.632
∞
0.781
Calculate the pseudo-first order rate constant k1 = k 2 [S2 O82 − ] and, hence, k2. Solution Table 3-6 gives D∞ – D with time t. For a first order rate law, the rate equation is expressed by ln
( D ∞ − D) = − k t 1 (D ∞ − D O )
(3-246)
Equation 3-246 is further expressed by ln (D∞ – D) = ln (D∞ – DO) – k1t
(3-247)
178
Modeling of Chemical Kinetics and Reactor Design
Table 3-6 t(sec)
D420
D∞ – D
0 900 1,800 2,700 3,600 4,500 ∞
0.120 0.290 0.420 0.510 0.581 0.632 0.781
0.661 0.491 0.361 0.271 0.200 0.149 0.0
that is, D ∞ − D = ( D ∞ − D O )e – k 1 t
(3-248)
Equation 3-248 is of the form Y = AeBX
(3-249)
Linearizing Equation 3-249 gives ln Y = ln A + BX
(3-250)
The computer program PROG1 determines the constants A and B from the regression analysis. Table 3-7 gives the results of the program with the slope –B equal to the reaction rate constant k1. Figure 3-19 shows a plot of ln (D∞ – D) against time t.
Table 3-7 t(sec) 0 900 1,800 2,700 3,600 4,500
Actual ln (D∞ – D)
Estimated ln (D∞ – D)
–0.414 –1.711 –1.019 –1.306 –1.609 –1.904
–0.416 –0.713 –1.011 –1.309 –1.609 –1.904
Reaction Rate Expression
179
Figure 3-19. Rate constants for the oxidation of Fe(CN)64 − to Fe(CN)63− .
The constants for the equation Y = A*EXP(B*X) are: • A = 0.660 • B = –33112 × 10–3 • Correlation Coefficient = 0.99997 The results give the pseudo-first order rate constant, and k1 = 3.312 × 10–4 sec–1 and k2 can be calculated as follows:
k2 =
[
k1 3.312 × 10 −4 1 1 = • 2− 1.8 × 10 −2 sec M S2 O 8
]
k 2 = 1.84 × 10 −2 M −1 • sec −1 Example 3-2
First order rate constant k, for the rotation about the C-N bond in N, N-dimethylnicotinamide (3) measured at different temperatures by nuclear magnetic resonance (NMR) are: T°C k sec–1
10.0 2.08
15.7 4.57
21.5 8.24
27.5 15.8
33.2 28.4
38.5 46.1
45.7 93.5
180
Modeling of Chemical Kinetics and Reactor Design
Determine the activation energy, E, and the pre-exponential factor, kO, for the rotation. Solution The activation energy E is a measure of the temperature sensitivity of the rate constant. A high E corresponds to a rate constant that increases rapidly with temperature. From the Arrhenius equation −E k T = k O exp RT
where kT kO E R T
= = = = =
(3-251)
rate constant at known temperature pre-exponential factor activation energy gas constant (8.314 J/mol • K) absolute temperature (K = 273.15 + °C)
It is possible to determine the activation energy E and the preexponential factor k0. Linearizing Equation 3-251 gives
ln k T = ln k O −
E RT
(3-252)
By plotting ln kT against 1/T, the slope equal to –E/R is obtained and the intercept equal to ln kO. From these known constants, activation energy E and the pre-exponential factor k O are determined. Equation 3-251 is of the form
Table 3-8 T(°C) 10 15.7 21.5 27.5 33.2 38.5 45.7
–1
k(sec )
T(K)
1/T
2.08 4.57 8.24 15.8 28.4 46.1 93.5
283.15 288.15 294.65 300.65 306.35 311.65 318.85
0.00353 0.00346 0.00339 0.00333 0.00326 0.00321 0.00314
Reaction Rate Expression
Y = AeBX
181
(3-253)
Linearizing Equation 3-253 gives ln Y = ln A + BX where ln Y = ln A = B = X =
(3-254)
ln kT ln kO –E/R 1/T
The computer program PROG1 determines the values of constants A and B. Table 3-9 gives the results of the program and the constants A and B The constants for the equation are: • A = 78728 × 1015 • B = –0.94869 × 104 • Correlation Coefficient = 0.99966 The slope B = –E/R = –0.9487 × 104 and A = kO = 7.873 × 1014. The activation energy E = R • B = 8.314 × 104 (J/mol) and E = 78.9 × 103 J/mol. The pre-exponential factor is kO = 7.87 × 1014 sec–1. Figure 3-20 gives a plot of ln kT against 1/T. Example 3-3
R. T. Dillon (1932) studied the reaction between ethylene bromide and potassium iodide in 99% methanol with the following data: Table 3-9 1/T
Actual ln k(sec–1)
Estimated ln k(sec–1)
0.00353 0.00346 0.00339 0.00333 0.00326 0.00321 0.00314
0.732 1.520 2.109 2.760 3.346 3.831 4.538
0.795 1.456 2.103 2.745 3.332 3.859 4.546
182
Modeling of Chemical Kinetics and Reactor Design
Figure 3-20. Rate constant k, for the rotation about the C-N bond in N,N-dimethylnicotamide (3).
k C 2 H 4 Br2 + 3 KI → C 2 H 4 + 2 KBr + KI 3
Temperature: 59.72°C Initial KI concentration: 0.1531 kmol/m3 Initial C2H4Br2 concentration: 0.02864 kmol/m3 Time, ksec
Fraction dibromide reacted
29.7 40.5 47.7 55.8 62.1 72.9 83.7
0.2863 0.3630 0.4099 0.4572 0.4890 0.5396 0.5795
Determine the second order reaction rate constant.
Reaction Rate Expression
183
Solution The reaction in stoichiometry can be represented as k A + 3B → Products
(3-255)
Assuming that the reaction is second order in a constant volume batch system, the rate equation is
(− rA ) =
− dC A = kC A C B dt
(3-256)
From stoichiometry: Amount at t = 0 Amount at t = t Amounts that have reacted
A
B
CAO CA (CAO – CA)
CBO CB (CBO – CB)
and (C BO – C B) = 3(C AO – C A). The fractional conversion X A is defined as
XA =
C AO − C A C AO
(3-257)
Therefore, CA = CAO(1 – XA)
(3-258)
Differentiating Equation 3-258 with respect to time t gives
−
dC A dX A = C AO dt dt
(3-259)
The concentration of B is
C B = C BO − 3 (C AO − C A )
(3-260)
In terms of the fractional conversion, the concentration of B is C B = C BO − 3 C AO X A
(3-261)
184
Modeling of Chemical Kinetics and Reactor Design
Substituting Equations 3-258 and 3-261 into Equation 3-256 gives −
dC A = k C AO (1 − X A ) (C BO − 3C AO X A ) dt
(3-262)
Substituting Equation 3-259 into Equation 3-262 and rearranging gives C AO dX A = k dt C AO (1 − X A ) (C BO − 3C AO X A )
(3-263)
Integrating Equation 3-263 between limits t = 0, XA = 0 and t = t, XA = XA gives XA
∫ 0
t
dX A = k dt (1 − X A ) (C BO − 3C AO X A ) ∫0
(3-264)
Equation 3-264 can be further expressed by XA
∫ 0
t
dX A = k ∫ dt C BO 0 − 3X A C AO (1 − X A ) C AO
(3-265)
where θB = CBO/CAO. Equation 3-265 becomes XA
∫ 0
t
dX A = k ∫ dt C AO (1 − X A )(θ B − 3X A ) 0
(3-266)
Converting Equation 3-266 into partial fraction gives A B 1 ≡ + (1 − X A )(θB − 3X A ) 1 − X A θB − 3X A 1 = A(θ B − 3X A ) + B(1 − X A )
(3-267)
Reaction Rate Expression
185
Equating the coefficients of the constant and XA gives “Const” “XA”
1 = AθB + B
(3-268)
0 = –3A – B
(3-269)
Adding simultaneous Equations 3-268 and 3-269 gives 1 = A(θB – 3). Therefore, A = 1/(θB – 3) and B = –3A = –3/(θB – 3). Equation 3267 is now expressed as
1 C AO
X A dX A − ∫ 0 (θ B − 3)(1 − X A )
XA
∫ 0
t 3 dX A = k dt (θB − 3) (θB − 3X A ) ∫0
=
1 −1 − ln (1 − X A ) − 3 ln (θ B − 3X A ) = kt C AO (θ B − 3) 3
=
(θ B − 3X A ) 1 = kt ln C AO (θ B − 3) (1 − X A )
(3-270)
Introducing the initial concentrations of A and B, that is, CAO and CBO into Equation 3-270 gives
1 C C AO BO − 3 C AO
C BO C AO − 3X A ln = kt 1− XA
C C − 3X A 1 ln BO AO = kt (C BO − 3C AO ) (1 − X A )
(3-271)
(3-272)
Rearranging Equation 3-272 gives C C − 3X A ln BO AO = kt (C BO − 3C AO ) 1 − XA
(3-273)
186
Modeling of Chemical Kinetics and Reactor Design
Equation 3-273 is of the form Y = AeBX and plotting ln{[CBO/(CAO – 3XA)]/1 – XA} against t gives the slope B = k(CBO – 3CAO). Table 3-10 gives the values of ln{[CBO/(CAO – 3XA)]/1 – XA} and t. The computer program PROG1 calculates the slope B from the equation Y = AeBX. From the slope, it is possible to determine the rate constant k. The constants for the equation are: • A = 5.325 • B = 0.0056969 • Correlation Coefficient = 0.99984 The slope = k(CBO – 3CAO) = 0.0057
C AO = 0.02864, C BO = 0.1531 k(0.1531 − 3 • 0.02864) = 0.0057 0.06718 k = 0.0057
m3 kmol k sec
k = 0.0848
= 0.0848
=
m3 l 1 kmol × 10 3 3 × kmol − k sec m 10 3 mol
0.0848 l sec × 3, 600 10 3 sec• mol hr
= 0.305
l mol − hr
Dillon obtained a value for the rate constant k = 0.300 1/(mol – hr). Figure 3-21 shows a plot of ln{[CBO/(CAO – 3XA)]/1 – XA} against time t, where Y = ln{[CBO/(CAO – 3XA)]/1 – XA}.
XA 0 0.2863 0.3630 0.4099 0.4572 0.4890 0.5396 0.5795
Time, t (ksec)
0 29.7 40.5 47.7 55.8 62.1 72.9 83.7 1 0.7137 0.637 0.5901 0.5428 0.511 0.4604 0.4205
1 – XA 5.3457 4.4868 4.2567 4.116 3.9741 3.8787 3.7269 3.6072
CBO C AO − 3X A
Table 3-10
5.346 6.287 6.682 6.975 7.321 7.590 8.095 8.579
CBO C AO − 3X A 1− X A
1.676 1.838 1.899 1.942 1.990 2.027 2.091 2.149
C C − 3X A ln BO AO 1 − XA
Reaction Rate Expression 187
188
Modeling of Chemical Kinetics and Reactor Design
Figure 3-21. Plot for determining the rate constant for the second order reaction.
Table 3-11 Run
Initial pressure B2H 6
(torr) Me2CO
Initial rate × 103 (torr/sec)
11 12 13 14 15 16 17 18 19 10
6.0 8.0 10.0 12.0 16.0 10.0 10.0 10.0 10.0 10.0
20.0 20.0 20.0 20.0 20.0 10.0 20.0 40.0 60.0 100.0
0.50 0.63 0.83 1.00 1.28 0.33 0.80 1.50 2.21 3.33
Example 3-4
Table 3-11 gives the initial rate data [–d(B2H6)/dt] reported for the gas phase reaction of diborane and acetone at 114°C: B2H6 + 4Me2CO → 2(Me2CHO)2BH. If a rate expression is of the form Rate m , determine n, m, and k. = kPBn2 H 6 PMe 2 CO Solution m Rate = kPBn2 H 6 PMe 2 CO
(3-274)
Reaction Rate Expression
189
Linearizing the rate expression gives ln ( Rate) = ln k + n ln PB2 H 6 + m ln PMe 2 CO
(3-275)
Equation 3-275 is of the form
Y = C O + C1 X1 + C 2 X 2
(3-276)
where the coefficients CO = k, C1 = n, and C2 = m. The computer program PROG3 determines the coefficients from the multiple regression of the independent variables PB2 H 6 and PMe 2 CO and the dependent variables Rate. The results of the program give the coefficients for Equation 3-276 as: • • • •
CO = 4.67755 C1 = 0.978166 C2 = 0.954575 Correlation Coefficient = 0.9930
Therefore, CO = k = 4.68, C1 = n = 0.98, and C2 = m = 0.95. The 0.95 , or as a rate equation is expressed as Rate = 4.68 PB0.298H 6 PMe 2 CO good approximation, Rate = 4.7 PB2 H 6 PMe 2 CO
(3-277)
The rate constant k can be determined with values of the exponents, m = n ≅ 1 as follows: 1.0 Rate = k PB1.20H 6 PMe 2 CO
k=
Rate PB2 H 6 PMe 2 CO
The average rate constant k = 3.85 and the final rate equation is Rate = 3.85 PB2 H 6 PMe 2 CO . The computed rate constant from PROG3 is 4.68 and the calculated value from Table 3-12 is 3.85. The percentage deviation between these values is 17.8%. Figure 3-22 shows plots of partial pressures of B2H6 and Me2CO versus the initial rate.
190
Modeling of Chemical Kinetics and Reactor Design
Table 3-12
Run
Initial pressure B2H 6
(torr) Me2CO
Initial rate × 103 (torr/sec)
Rate constant k
11 12 13 14 15 16 17 18 19 10
6.0 8.0 10.0 12.0 16.0 10.0 10.0 10.0 10.0 10.0
20.0 20.0 20.0 20.0 20.0 10.0 20.0 40.0 60.0 100.0
0.50 0.63 0.83 1.00 1.28 0.33 0.80 1.50 2.21 3.33
4.17 3.94 4.15 4.17 4.00 3.33 4.00 3.75 3.68 3.33
Figure 3-22. Plots of partial pressures of B 2H 6 and Me 2 CO versus the initial rate.
Example 3-5
For the irreversible thermal dissociation of paraldehyde at 259°C and constant volume, the following data were obtained: Time, hrs PTotal, mm Hg
0 100
1 175
2 220
3 250
4 270
∞ 300
Reaction Rate Expression
191
Determine the order of the reaction and the rate constant. Solution Paraldehyde decomposition is represented by (CH 3CHO)3 1 → 3CH 3CHO . The stoichiometry of the reaction is of the form k A 1 → 3B . Assuming that the reaction is first order, then the rate equation for a constant volume batch system is: k
(− rA ) =
−
dC A = k1C A dt
(3-278)
If the reactant and product obey the ideal gas law, the concentration is
CA =
nA p = A V RT
(3-279)
In terms of the partial pressure pA,
−
dp A = k1p A dt
(3-280)
Rearranging Equation 3-280 and integrating between the boundary conditions (at t = 0, pA = pAO and at t = t, pA = pA) gives: pA
∫
p AO
t
dp − k1 ∫ dt pA 0
(3-281)
Equation 3-281 gives ln
pA = − k 1t p AO
(3-282)
If nA is the number of moles of paraldehyde at time t and nAO, the moles of paraldehyde at t = 0, then at time t, moles of acetaldehyde from stoichiometry are:
192
Modeling of Chemical Kinetics and Reactor Design
Amount at t = 0 Amount at t = t Amounts that have reacted
A
B
nAO nA (nAO – nA)
n BO nB nB – nBO
and from stoichiometry 3( n AO − n A ) = ( n B − n BO ) . Total moles at time t = n T = n A + 3( n AO − n A ) + n BO , although nBO = 0. If the gas law applies, then n = pV/RT, and at constant V and T: PT = p A + 3( p AO − p A ) = p A + 3p AO − 3p A
PT = 3p AO − 2 p A or
pA =
1 (3p AO − PT ) 2
where PT = total pressure pA = partial pressure of A (paraldehyde) at time t pAO = partial pressure of A at time t = 0 Table 3-13 shows the relationship between the ratio of pA/pAO versus time t. A plot of ln pA/pAO against time t (Figure 3-23) gives a straight line with the slope equal to the rate constant k 1 . Therefore, the assumed first order for the reaction is correct. The relationship between the ratio of pA/pAO versus time t is represented by the model equation Y = AeBX. The computer program PROG1 determines the rate constant k1 from the slope of Y = AeBX. The constants for the equation are: • A = 1.0082 • B = –0.47105 • Correlation Coefficient = 0.99972 The slope B = k 1. Therefore, the model equation Y = Ae BX is 0.471 hr–1.
Reaction Rate Expression
193
Table 3-13 Time, hr 0 1 2 3 4 ∞
PT, mmHg at 0°C
pA = 1/2(3pAO – P T)
100 = pAO 175 220 250 270 300
100 62.5 40.0 25.0 15.0 0
pA/pAO 1.0 0.625 0.400 0.250 0.15 0.0
Figure 3-23. Plot of ln pA/pAO versus time t.
Example 3-6 k → 2 NO + Cl 2 is studied at 200°C. The The reaction 2 NOCl concentration of NOCl initially consisting of NOCl only changes as follows:
t, sec CNOCl, gmol/l
0 0.02
200 0.016
300 0.0145
500 0.012
194
Modeling of Chemical Kinetics and Reactor Design
Determine the order of the reaction and the rate constant. Solution If the reaction is second order, the rate equation is:
(− rA ) = −
dC A = kC 2A dt
(3-283)
Rearranging Equation 3-283 and integrating with the boundary conditions, at t = 0, CA = CAO and at t = t, CA = CA, gives
−
CA
∫
C AO
t
dC A = k ∫ dt C 2A 0
(3-284)
1 1 − = kt C A C AO
(3-285)
A plot of 1/CA versus t gives a straight line with the slope = k = 0.06661/gmol•s. The computer program PROG1 determines the rate constant for a second order reaction. Equation 3-285 is of the form 1/Y = A + BX where the slope B is the rate constant k. The results of the computer program are shown in Table 3-14. The constants for the equation are: • A = 0.496 × 102 • B = 0.0666 • Correlation Coefficient = 0.9992
Table 3-14 Time, sec
Actual 1/CNOCl, gmol/l
Estimated 1/CNOCl, gmol/l
0 200 300 500
50 62.5 68.97 83.3
49.6 62.9 69.5 82.8
Reaction Rate Expression
195
Figure 3-24 shows the relationship between 1/CA as a function of time t. The graph is a straight line, therefore, the assumed order of the reaction is correct. The slope of the line from the regression analysis is the rate constant k. The rate constant k = 0.0666
l gmol • sec
Example 3-7
The gas phase decomposition A → B + 2C is conducted in a constant volume reactor. Runs 1 through 5 were conducted at 100°C; run 6 was performed at 110°C (Table 3-15). Determine (1) the reaction order and the rate constant, and (2) the activation energy and frequency factor for this reaction. Solution The half-life for the nth order reaction is: t1 2 =
2 n −1 − 1 1 n −1 k( n − 1) C AO
Figure 3-24. Plot of 1/CA against time (sec).
(3-286)
196
Modeling of Chemical Kinetics and Reactor Design
Table 3-15 Half-life t1/2 as function of initial concentration CAO Run number 1 2 3 4 5 6
CAO, gmol/l
Half-life, t1/2 min
0.025 0.0133 0.01 0.05 0.075 0.025
4.1 7.7 9.8 1.96 1.30 2.0
Taking the natural logarithm of Equation 3-286 yields
( )
ln t1 2 = ln
2 n −1 − 1 + (1 − n ) ln C AO k( n − 1)
(3-287)
A plot of CAO versus t1/2 on log-log paper should give the slope of the line equal to (1 – n). However, Equation 3-287 can also be represented in the form Y = AXB
(3-288)
Linearizing Equation 3-288 gives ln Y = ln A + B ln X
(3-289)
The constants for Equation 3-289 are: • A = 0.0878 • B = 1.0032 • Correlation Coefficient = 0.97195 The slope of the line B = 1 – n. The computer program PROG1 gives the slope B = –1.003, therefore, the order of reaction n = 2. When t1/2 = 5 min, and CAO = 0.022 gmol/l at 100°C, then from Equation 3-286
k100 =
2 n −1 − 1 1 n −1 ( n − 1) C AO t1 2
Reaction Rate Expression
=
197
2 −1 1 1 × × 1 0.022 5
= 9.09 l gmol • min
At 110°C, CAO = 0.025 gmol/l, t1/2 = 2 min, and
k110 =
2 −1 1 1 × × 1 0.025 2
= 20 l gmol • min
The activation energy and frequency factor can be determined from the Arrhenius equation
−E k T = k O exp RT where kT kO E R
= = = =
(3-290)
rate constant at known temperature frequency factor activation energy ideal gas constant 1.987cal/mol • K
−E k100 = k O exp R(373)
(3-291)
−E k110 = k O exp R(383)
(3-292)
Dividing Equation 3-291 by Equation 3-292 gives k100 exp( − E R(373)) = k110 exp( − E R(383))
(3-293)
Removing the exponential, Equation 3-293 can be expressed as
198
Modeling of Chemical Kinetics and Reactor Design
ln
k100 −E −E = − k110 R(373) R(383)
ln
9.09 E 1 1 = − 20.0 R 383 373
E=
−0.7886 × 1.987 −6.999 × 10 −5
= 22, 388
cal gmol
The frequency factor at 100°C is kO =
=
k100 −E exp RT
9.09 − 22, 388 exp 1.987 × 373
= 1.19 × 1014 l gmol • min The frequency factor at 110°C is kO =
=
k110 −E exp RT
20 − 22, 388 exp 1.987 × 383
= 1.19 × 1014 l gmol • min
(3-294)
Reaction Rate Expression
199
Example 3-8
The hydrolysis of methyl acetate is an autocatalytic reaction and is first order with respect to both methyl acetate and acetic acid. The reaction is elementary, bimolecular and can be considered irreversible at constant volume for design purposes. The following data are given: • Initial concentration of methyl acetate = 0.45 gmol/l • Initial concentration of acetic acid = 0.045 gmol/l The conversion in 1 hr is 65% in a batch reactor. Calculate (1) the rate constant and specify the rate equation, (2) the time at which the rate passes through the maximum, and (3) the type of optimum reactor system needed for the plant to process 200 m3/hr. What would be the reactor volume in this system? Solution The hydrolysis of methly acetate can be represented by k
CH 3COOCH 3 + H 2 O 1 → CH 3COOH + CH 3OH (A)
( B)
That is, A → B. For an autocatalytic reaction A + B → B + B and the rate of disappearance of species A is
(− rA ) =
−
dC A = k1C A C B dt
(3-295)
The solution for an autocatalytic reaction is ln
θB + X A = (C AO + C BO ) k1t θ B (1 − X A )
where
θB =
C BO 0.045 = = 0.1 C AO 0.45
at t = 1 hr, XA = 0.65
(3-296)
200
Modeling of Chemical Kinetics and Reactor Design
The rate constant k1 is
θB + X A θ B (1 − X A ) k1 = (C AO + C BO ) t ln
=
ln(0.75 0.035) (0.495) (1)
= 6.191 l gmol − hr = 6.2 l gmol − hr
The rate equation is
(− rA ) = −
dC A = 6.2 C A C B dt
l gmol − hr
The rate is at maximum when CA = CB. From stoichiometry: C AO − C A = C B − C BO
and C A + C B = C AO + C BO
= (0.45 + 0.045)
= 0.495 Therefore, 1 C A = C B = × 0.495 2 = 0.2475 The corresponding fractional conversion XA is
Reaction Rate Expression
201
C AO − C A 0.45 − 0.2475 = = 0.45 C AO 0.45 Therefore, the time t at which the rate reaches the maximum is: θ + XA ln B θ B (1 − X A ) t= k1 (C AO + C BO )
0.1 + 0.45 ln 0.1(1 − 0.45) = (0.62)(0.495)
0.55 ln 0.055 = 3.069
= 0.75 hr ( 45 min ) The type of optimum reactor that will process 200 m3/hr is a continuous flow stirred tank reactor (CFSTR). This configuration operates at the maximum reaction rate. The volume VR of the reactor can be determined from the design equation: t=
VR u
where VR = volume of the reactor u = volumetric flow rate of the fluid t = mean residence time of the fluid Therefore, the volume VR = t • u = 0.75 × 200 = 150 m3
202
Modeling of Chemical Kinetics and Reactor Design
Example 3-9
Huang and Dauerman (1969) have studied the acetylation of benzyl chloride in dilute solution at 102°C. Using equimolal concentrations of sodium acetate and benzyl chloride (0.757 kmol/m3), Table 3-16 lists the reported data on the fraction of benzyl chloride remaining unconverted versus time. Determine the order of the reaction and the reaction rate constant at this temperature. Solution The reaction is assumed to be second order as represented by NaAc + C6H5CH2Cl → C6H5CH2Ac + Na+ + Cl–, which can be expressed in terms of components A and B as k A+B → Products
(3-297)
The rate equation for component B is
(− rB ) =
−
dC B = kC A C B dt
(3-298)
The stoichiometry for components A and B is:
Table 3-16 Time, t (ksec) 10.80 24.48 46.08 54.72 69.48 88.56 109.44 126.72 133.74 140.76
CB/CBO where B = C6H5CH2Cl 0.945 0.912 0.846 0.809 0.779 0.730 0.678 0.638 0.619 0.590
Reaction Rate Expression
Amount at t = 0 Amount at t = t Amounts that have reacted
203
A
B
CAO CA CAO – CA =
CBO CB CBO – CB
In terms of the fractional conversion of B, XB
XB =
C BO − C B C BO
(3-299)
Equation 3-299 is further expressed as:
C B = C BO (1 − X B )
(3-300)
Since the concentration of A and B is the same, then C A = C B = C BO (1 − X B )
(3-301)
and
−
dC B dX B = C BO dt dt
(3-302)
Substituting Equations 3-300 and 3-302 into Equation 3-298 gives
(− rB ) = C BO
dX B 2 = kC 2BO (1 − X B ) dt
(3-303)
Rearranging Equation 3-303 and integrating between the limits t = 0, XB = 0 and t = t, XB = XB gives XB
dX B
∫ (1 − X )2 B 0
t
= kC BO ∫ dt
(3-304)
0
XB
1 = kC BO t − X 1 B 0
(3-305)
204
Modeling of Chemical Kinetics and Reactor Design
1 − 1 = kC BO t 1 − X B
(3-306)
1 − 1 = kC BO t C B C BO
(3-307)
The rate constant k can be calculated from Equation 3-307 as: k=
1 − 1 C BO t C B C BO 1
(3-308)
Table 3-17 shows the calculated values of the rate constant k at varying time t. Discounting the first and the last two values of the rate constant k, the average value of the rate constant is k = 0.0055 m3/(mol • sec). This shows that the rate of reaction is second order. Example 3-10
(1) Suppose a first-order reaction (n = 1) is preformed in an isothermal batch reactor of constant volume V. Write a material balance
Table 3-17 Time, t (ksec) 10.48 24.48 46.08 54.72 69.48 88.56 109.44 126.72 133.74 140.76
CB/CBO
1 − 1 CB CBO
CBO t
0.945 0.912 0.846 0.809 0.779 0.730 0.678 0.638 0.619 0.590
0.058 0.096 0.182 0.236 0.284 0.370 0.475 0.567 0.616 0.695
0.122 0.054 0.029 0.024 0.019 0.015 0.012 0.010 0.010 0.005
1
k
m3 mol • sec 0.0071 0.0052 0.0053 0.0057 0.0054 0.0056 0.0057 0.0057 0.0062 0.0034
Reaction Rate Expression
205
on A and integrate it to derive the expression CA = CAO exp(–kt), where CAO is the concentration of A in the reactor at t = 0. (2) The gas-phase decomposition of sulfuryl chloride, SO2Cl2 → SO2 + Cl2, is thought to follow a first order rate law. The reaction is performed in a constant volume, isothermal batch reactor, and the concentration of SO2Cl2 is measured at several reaction times, with the following results. t(min) CA(mol/l)
4.0 0.0158
20.2 0.0152
40.0 0.0144
60.0 0.0136
120.0 0.0116
180.0 0.0099
Use these results to verify the proposed law and determine the rate constant k. Give both the value and units of k. Solution (1) Assuming that the reaction is first order in an isothermal batch reactor of constant volume, then the rate equation for the reaction k A 1 → Products is
(− rA )
= −
1 dn A = k1C A V dt
(3-309)
where the number of moles nA is nA = CAV
(3-310)
where CA = concentration of species A V = volume of the batch reactor Substituting Equation 3-310 into Equation 3-309 yields
(− rA ) = − =−
1 d(VC A ) = k1C A V dC A = k1C A dt
since V is constant.
(3-311)
206
Modeling of Chemical Kinetics and Reactor Design
Rearranging Equation 3-311 and integrating between the limits at t = 0, CA = CAO and t = t, CA = CA gives CA
∫
C AO
t
dC A = − k1 ∫ dt CA 0
(3-312)
and
ln
CA = − k 1t C AO
(3-313)
Therefore, C A = C AO exp( − k1t )
(3-314)
(2) Using Equation 3-314 for the gas-phase decomposition of sulfuryl chloride, it can represented by Y = AeBX
(3-315)
Linearizing Equation 3-315 gives ln Y = ln A + BX
(3-316)
Table 3-18 shows the concentration of SO2Cl2, CA as a function of time, t. A plot of ln CA versus time t gives a straight line with slope (–B) equal to the rate constant k1. The constants of the equation Y = AeBX are:
Table 3-18 Time (min) 4.0 20.2 40.0 60.0 120.0 180.0
CA, mol/l
ln CA, mol/l
0.0158 0.0152 0.0144 0.0136 0.0166 0.0099
–4.1477 –4.1865 –4.2405 –4.2977 –4.4568 –4.6152
Reaction Rate Expression
207
• A = 0.015999 • B = –0.26711 × 10–2 • Correlation Coefficient = 0.99991 The rate constant k1 = –B = 0.00267 sec–1. Figure 3-25 gives a plot of ln CA versus time t (min). Example 3-11
A gas decomposition reaction with stoichiometry 2A → 2B + C follows a second order rate law rd ( mol / m 3 • s) = kC 2A , where CA is the reactant concentration in mol/m3. The rate constant k varies with the reaction temperature according to the Arrhenius law: −E k ( m 3 mol • s) = k O exp RT
where kO(m3/mol•s) = pre-exponential factor E(J/mol) = reaction activation energy R = gas constant (1) Suppose the reaction is performed in a batch reactor of constant volume V(m3) at a constant temperature T(K), beginning with pure A
Figure 3-25. Plot of ln CA versus t.
208
Modeling of Chemical Kinetics and Reactor Design
at a concentration CAO. Write a differential balance on A and integrate it to obtain an expression for CA(t) in terms of CAO and k. (2) Let PO(atm) be the initial reactor pressure. Prove that t1/2, the time required to achieve 50% conversion of A in the reactor, equals RT/kpO. Assume an ideal gas behavior. (3) The decomposition of nitrous oxide (N 2O) to nitrogen and oxygen is preformed in a 5.0 l batch reactor at a constant temperature of 1,015 K, beginning with pure N2O at several initial pressures. The reactor pressure P(t) is monitored, and the times (t1/2) required to achieve 50% conversion of N2O are noted in Table 3-19. Use these results to verify that the N2O decomposition reaction is second order and determine the value of k at T = 1,015 K. (4) The same experiment is performed at several other temperatures at a single initial pressure of 1.0 atm. The results are shown in Table 3-20. Determine the Arrhenius law parameters (kO and E) for the reaction. Solution (1) Since the reaction is carried out in a batch system of constant volume, the rate expression for a second order rate law is
(− rA ) = − V1
dn A dC = − A = kC 2A dt dt
(3-317)
where k = kO exp(–E/RT).
Table 3-19 PO(atm) t1/2(sec)
0.135 1,060
0.286 500
0.416 344
0.683 209
1,000 219
1,050 55
Table 3-20 T(K) t1/2(sec)
900 5,464
950 1,004
Reaction Rate Expression
209
Rearranging Equation 3-317 and integrating between the limits t = 0, CA = CAO and t = t, CA = CA gives
−
CA
∫
C AO
t
dC A = k ∫ dt C 2A 0
(3-318)
Integrating Equation 3-318 yields CA
1 = kt C C AO A
(3-319)
1 1 E − = k O exp − t RT C A C AO
(3-320)
Therefore, the concentration of species A in terms of CAO and k is 1 1 E = + k O exp − t C A C AO RT
(3-321)
(2) The half-life t1/2 equation for the general nth-order reaction is
(2 n −1 − 1) C1AO− n
t1 2 =
k( n − 1)
(3-322)
Since the reaction order is two, that is n = 2, this can be substituted in Equation 3-322 to obtain t1 2 =
−1 C AO 1 = k kC AO
(3-323)
where C AO =
n AO p AO V p AO = = V RT V RT
Substituting Equation 3-324 into Equation 3-323 gives
(3-324)
210
Modeling of Chemical Kinetics and Reactor Design
t1 2 = =
1 kp AO RT RT kp AO
(3-325)
(3) The decomposition of nitrous oxide (N 2O) to nitrogen and oxygen is represented by 2N 2O → 2N 2 + O2
(3-326)
The half-life t1/2 of the general nth order reaction is t1 2 =
(2 n −1 − 1) C1AO− n k( n − 1)
Therefore, using Equation 3-324 gives
t1 2 =
2 n −1 − 1 p AO k( n − 1) RT
1− n
(3-327)
Taking the natural logarithm of Equation 3-327 gives
( )
ln t1 2 = ln
p 2 n −1 − 1 + (1 − n ) ln AO RT k( n − 1)
(3-328)
Equation 3-328 can be expressed in the form Y = AXB
(3-329)
Linearizing Equation 3-329 gives ln Y = ln A + B ln X
(3-330)
where the slope B = 1 – n. From Table 3-19, we can construct the independent variable pO/RT at the constant temperature of 1,015 K and the gas constant R = 0.08206 (l • atm/mol • k) (Table 3-21). The dependent variable is t1/2.
Reaction Rate Expression
211
Table 3-21 pO, atm
t1/2 (sec)
pO/RT × 10–3
t1/2-estimated
0.135 0.286 0.416 0.683
1,060 500 344 209
1.6208 3.4337 4.9945 8.2001
1,059.8 ,501.7 ,342.2 ,209.5
The constants for Equation 3-330 from PROG1 are: • A = 1.7834 • B = –0.992 • Correlation Coefficient = 1.0 The slope B = –0.9922 = 1 – n. Therefore, the value of n = 1.992 ≅ 2 and the reaction is second order. The value of the rate constant k at T = 1,015 K is
t1 2 =
RT kp O
Therefore, k=
0.08206 × 1, 015 l • atm RT K • = 0.135 × 1, 060 p O t1 2 mol − K atm • sec
= 0.582
l mol • sec
(4) Applying the Arrhenius equation −E k T = k O exp RT
(3-331)
Linearizing Equation 3-331 gives ln k T = ln k O −
E RT
(3-332)
212
Modeling of Chemical Kinetics and Reactor Design
The rate constant kT can be determined at varying temperature T from the half-life t1/2 as follows: 2 n −1 − 1 RT t1 2 = k T ( n − 1) p AO
n −1
(3-327)
At the initial pressure of 1 atm, pAO = 1 and n = 2. Therefore, t1/2 in Equation 3-327 is t1/2 = RT/kT and kT = RT/t1/2. Table 3-22 can be constructed from Table 3-20 for values of kT, the dependent variable, from varying temperature T and t1/2. Equation 3-331 is of the form Y = AeBX
(3-333)
Linearizing the model Equation 3-333 gives ln Y = ln A + BX
(3-334)
where the constant A = kO, and the slope B = –E/R. The computer program PROG1 determines the constants A and B. The constants for Equation 3-330 are: • A = 0.3378 × 1013 • B = –0.29875 × 105 • Correlation Coefficient = 0.9999 The gas constant R = 0.08206 l • atm/mol • K.
Table 3-22 T(K)
t1 2 (sec)
1/T
RT kT (l mol • sec) t1 2
900 950 1,000 1,050
5,464 1,004 219 55
0.00111 0.00105 0.001 0.00095
0.0135 0.0776 0.3747 1.5666
Reaction Rate Expression
213
E = B = − 0.2988 × 10 5 R
The activation energy −
= 0.2988 × 10 5 × 0.08206
= 2, 452
l mol
The value of the pre-exponential factor kO = 3.378 × 1012 l/mol • sec. Example 3-12
For the synthesis of ammonia, N2 + 3H2 → 2NH3, over an iron catalyst, develop the rate expression for the following mechanism H 2 ( g ) + 2S
k1
[ 2HS k −1
k
2 N 2( g ) + 2S → 2 NS
NS + 3HS
k3
[ k
−3
NH 3S + 3S
(3-335)
(3-336)
(3-337)
k4
NH 3S [ NH ( g ) + S k −4
(3-338)
Solution Boudart (1972) introduced the assumption of the most abundant surface intermediate (masi). This assumption suggests that the sites occupied by all species except the most abundant surface intermediate is regarded as negligible compared to those filled by the most abundant intermediate and to those which are empty. The rate expression for the above mechanism is based on the following assumptions: 1. The most abundant surface intermediate is NS that CT = Cs + CNS.
(3-339)
214
Modeling of Chemical Kinetics and Reactor Design
2. Steps 1, 3, and 4 are in equilibrium and step 2 is the ratedetermining step. 3. The conditions at which the reaction N2 + 3H2 → 2NH3 are performed are such that the reverse rate is negligible. CT = total concentration of sites and defined as
total moles of sites unit mass of catalyst CS = concentration of vacant sites CHS = concentration of adsorbed hydrogen
moles of hydrogen adsorbed unit mass of catalyst CNS = concentration of the most abundant surface intermediate C NH3S = concentration of adsorbed ammonia
moles of ammonia adsorbed unit mass of catalyst p N 2 = partial pressure of nitrogen p NH3 = partial pressure of ammonia ( −rN 2 ) = rate of reaction of nitrogen, moles of nitrogen disappearing per unit time per unit mass of catalyst Since step 2 is the rate-determining step, then the rate expression is:
(− r ) = k p N2
2 2 N 2 CS
(3-340)
The net rate of the disappearance of H2 is given by
(− r )
H 2 net
= k1p H 2 C S2 − k −1C 2HS
(3-341)
On the basis of the pseudo-steady state assumption, the net rate of disappearance is zero, therefore
k1p H 2 C S2 = k −1C 2HS
Reaction Rate Expression
215
and C 2HS k1 = k −1 p H 2 C S2
K1 =
C 3S C NH 3S k3 = k −3 C NS C 3HS
K3 =
K4 =
(3-342)
(3-343)
C S p NH 3 k4 = k −4 C NH 3S
(3-344)
From Equation 3-343, the concentration of the most abundant surface intermediate is C NS =
Cs3 C HN 3S
(3-345)
K 3C 3HS
The concentration of adsorbed ammonia from Equation 3-344 is
C NH 3S =
C S p NH 3
(3-346)
K4
The concentration of adsorbed hydrogen from Equation 3-342 is
(
C HS = K1p H 2 C S2
)
12
(3-347)
Substituting Equations 3-346 and 3-347 into Equation 3-345 gives C NS =
=
C S3 C S p NH 3
(
K 3K 4 K1p H 2 C S2 p NH 3 C S K p1H.52
)
32
(3-348)
(3-349)
216
Modeling of Chemical Kinetics and Reactor Design
where K = K11.5 K 3 K 4 . Substituting Equation 3-349 into Equation 3-339 yields CT =
p NH 3 C S K p1H.52
+ CS
(3-350)
or CS =
CT p NH 3 Kp1H.52
(3-351) + 1
Substituting Equation 3-351 into the rate expression of Equation 3-340 gives
(− r ) N2
CT = k 2 pN2 p NH 3 Kp1.5 + 1 H2
2
(3-352)
REFERENCES 1. Boudart, M., Kinetics of Chemical Processes, Chapter 1, Prentice Hall, Englewood Cliffs, NJ, 1968. 2. Mc. Tigue, P. T. and Sime, J. M., J. Chem. Soc., 1303, 1963. 3. Dixon, N. E., Jackson, W. G., Marty, W., and Sargeson, A. M., “Base Hydrolysis of Pentaamminecobalt (III) Complexes of Urea, Dimethyl Sulfoxide and Trimethyl Phosphate,” Iorg., Chem., 21, 688–697, 1982. 4. Levenspiel, O., The Chemical Reactor Omnibook, OSU Book Stores, Inc., 1993. 5. Boudart, M., “Two-Step Catalytic Reactions,” AIChEJ, Vol. 18, No. 3, pp. 465–478, 1972. 6. Bacon, D. W. and J. Downie, “Evaluation of Rate Data III,” AIChE MI Series E: Kinetics Vol. 2, Reactors and Rate Data, AIChE, 1981.
Reaction Rate Expression
217
7. Holt, M. J. and Norris, A. C., “A New Approach to the Analysis of First-Order Kinetic Data,” Journal of Chemical Education, Vol. 54, No. 7, pp. 426–428, 1977. 8. Norris, A. C., Computational Chemistry—An Introduction to Numerical Methods, John Wiley & Sons Ltd., 1981. 9. Weller, S., “Analysis of Kinetic Data for Heterogeneous Reactions,” AIChE. J, Vol. 2, No. 1, pp. 59–61, 1956. 10. Cox, B. G., Modern Liquid Phase Kinetics, Oxford Chemistry Primers, Oxford University Press, 1996. 11. Hill, C. G. Jr., An Introduction to Chemical Kinetics & Reactor Design, John Wiley & Sons, New York, 1977. 12. Fogler, H. S., Elements of Chemical Reaction Engineering, 3rd ed. Prentice-Hall International Series, 1999. 13. Dillon, R. T., J. Am. Chem. Soc., 54 (952), 1932. 14. Huang and Dauerman, Ind. Eng. Chem. Product Research & Development, 8, 227, 1969.
218
Modeling of Chemical Kinetics and Reactor Design
CHAPTER FOUR
Industrial and Laboratory Reactors INTRODUCTION Chemical reactors are the most important features of a chemical process. A reactor is a piece of equipment in which the feedstock is converted to the desired product. Various factors are considered in selecting chemical reactors for specific tasks. In addition to economic costs, the chemical engineer is required to choose the right reactor that will give the highest yields and purity, minimize pollution, and maximize profit. Generally, reactors are chosen that will meet the requirements imposed by the reaction mechanisms, rate expressions, and the required production capacity. Other pertinent parameters that must be determined to choose the correct type of reactor are reaction heat, reaction rate constant, heat transfer coefficient, and reactor size. Reaction conditions must also be determined including temperature of the heat transfer medium, temperature of the inlet reaction mixture, inlet composition, and instantaneous temperature of the reaction mixture. An important factor in reactor operation is the outlet degree of conversion. Operating conditions such as temperature, pressure, and degree of agitation, are related for the most economic operation. The optimum reactor that will best meet the process requirements requires a review of whether the process is continuous or batch, and whether a combination of reactor types or multiple reactors in series or parallel would be most adequate. It is also important to determine whether the mode of operation involves either an isothermal (i.e., constant temperature) or an adiabatic (i.e., heat does not exchange with the surroundings) condition, whether a single pass operation is best, or whether recycling is needed to achieve the desired degree of conversion of the raw feedstock. The degree of conversion affects the
218
Industrial and Laboratory Reactors
219
economics of separating the reaction mixture and the costs of returning the unconverted reactant back into the reaction. In chemical laboratories, small flasks and beakers are used for liquid phase reactions. Here, a charge of reactants is added and brought to reaction temperature. The reaction may be held at this condition for a predetermined time before the product is discharged. This batch reactor is characterized by the varying extent of reaction and properties of the reaction mixture with time. In contrast to the flasks are large cylindrical tubes used in the petrochemical industry for the cracking of hydrocarbons. This process is continuous with reactants in the tubes and the products obtained from the exit. The extent of reaction and properties, such as composition and temperature, depend on the position along the tube and does not depend on the time. Another classification refers to the shape of the vessel. In the case of the laboratory vessel installed with a stirrer, the composition and temperature of the reaction is homogeneous in all parts of the vessel. This type of vessel is classified as a stirred tank or well mixed reactor. Where there is no mixing in the direction of flow as in the cylindrical vessel, it is classified as a plug flow or tubular flow reactor. Knowledge of the composition and temperature at each point of the reactor enables the designer to describe the behavior of a chemical reactor. Concentrations of species at any point may change either because the species are consumed by chemical reaction or they reach this position via mass transfer. Correspondingly, the temperature at any point may change because the heat is being absorbed or released by chemical reaction or heat transfer. The rate of the chemical reaction and the rate of mass and heat transfer affect the concentration and temperature of a given section of the system. Concentration, temperature, and molecular properties determine the reaction rate. This process occurs through microkinetic properties that are identical in any chemical reactor (i.e., if the temperature and composition in two reactors are the same, then the reaction rate is also the same). Macrokinetic properties of the reactor affect the outcome of the process through the kinetics of heat and mass transfer. The rates of mass and heat transfer depend on the properties relative to the reactor, such as size of the reactor, size and speed of the impeller, and the area of heat exchanging surfaces. Reactors without the effect of macrokinetic properties are composed of elements that are either perfectly insulated from the viewpoint of
220
Modeling of Chemical Kinetics and Reactor Design
mass and heat transfer or at equilibrium with the surroundings. Reactors that are free of the effect of macrokinetic properties are classified as: • Batch isothermal perfectly stirred reactor (the reaction mixture is at equilibrium with the heat transfer medium). • Batch adiabatic perfectly stirred reactor. • Semi-batch perfectly stirred reactor. • Continuous isothermal perfectly stirred flow reactor (the reaction mixture is at equilibrium with the heat transfer medium). • Continuous adiabatic perfectly stirred flow reactor. • Continuous isothermal plug flow reactor (the reactor mixture is at thermal equilibrium with the surroundings). • Continuous adiabatic plug flow reactor. Knowledge of these types of reactors is important because some industrial reactors approach the idealized types or may be simulated by a number of ideal reactors. In this chapter, we will review the above reactors and their applications in the chemical process industries. Additionally, multiphase reactors such as the fixed and fluidized beds are reviewed. In Chapter 5, the numerical method of analysis will be used to model the concentration-time profiles of various reactions in a batch reactor, and provide sizing of the batch, semi-batch, continuous flow stirred tank, and plug flow reactors for both isothermal and adiabatic conditions.
BATCH ISOTHERMAL PERFECTLY STIRRED REACTOR The concept of a batch reactor assumes that the reaction is instantaneously charged (i.e., filled) and perfectly homogenized in the reactor. Also, its temperature is immediately adjusted to that of the heat transfer medium. Therefore, the chemical reaction takes place at the temperature of the heat transfer medium under perfect mixing. The process is stopped as soon as the degree of conversion is achieved. Figure 4-1 shows two nozzles at the top of a batch reactor where charging of the reactants occurs. Batch reactors are used extensively in a final scale-up of an industrial plant. The choice of a batch reaction over a continuous system is often a result of special considerations. The size of batch reactors range from 5 gal (19 l) in small industrial pilot plants to 10,000–20,000 gal (38,000–76,000 l) in large plants.
Industrial and Laboratory Reactors
221
Figure 4-1. A batch homogeneous-type reactor.
When larger sizes are required, the design may include multiple units of batch reactors arranged in parallel. In small industrial pilot plants, a batch system may be employed for preliminary information. Also, batch reactors can be used in these plants to obtain small quantities of the new product for further evaluations such as purity, yield, and sales. At the industrial level, batch
222
Modeling of Chemical Kinetics and Reactor Design
reactors are used in the pharmaceutical, biochemical, or multi-product plants as in the dye industry. These reactors or autoclaves require suitable access for inserting agitators, coils, or other internal devices and for cleaning. Figure 4-2 shows a steam-jacketed autoclave and Figure 4-3 is a 120-gal, steam-jacketed autoclave for processing organic chemicals at 2,000 psi and 300°F. The advantages of a batch reactor are: • Simple in construction. • Small instrumentation and cost. • Flexibility of operation. The principal disadvantage of a batch reactor is in the labor cost. Labor cost includes the time it takes to fill the reactor, heat it to reaction temperature, cool it after completion of the reaction, discharge the reactor contents, and clean the reactor for the next batch. These procedures increase the overall labor costs per unit of production. Another disadvantage involves the difficulty to control heat transfer and product quality. Chemical reaction rates usually increase with temperature and with more intimate contact between reactants. Mechanical agitation promotes the flow of heat by forcing convection of the mass and by reducing the film resistance at the vessel wall. Additionally, agitation breaks up agglomerated solids thereby increasing the contact surface and the rate at which reacting species come into close proximity. An important purpose of agitation or mixing is to bring a number of materials together in a physically homogeneous mixture. Two or more fluids are either blended or dispersed as emulsions; fluids and finely divided solids are dispersed as suspensions, gases dispersed as fluids, or soluble substances dissolved. Mixing of process fluids is reviewed in Chapter 7.
SEMI-BATCH REACTORS Figure 4-4 shows a semi-batch reactor with outside circulation and the addition of one reactant through the pump. Semi-batch reactors have some reactants that are charged into the reactor at time zero, while other reactants are added during the reaction. The reactor has no outlet stream. Some reactions are unsuited to either batch or continuous operation in a stirred vessel because the heat liberated during the reaction may cause dangerous conditions. Under these
Industrial and Laboratory Reactors
223
Figure 4-2. Jacketed batch reactor. (Source: D. B. Gooch, “Autoclaves Pressure—Temperature Reactions,” Ind. Eng. Chem., 35, 927–946, 1943. Used with permission from the American Chemical Society.)
224
Modeling of Chemical Kinetics and Reactor Design
Figure 4-3. A 120-gal steam-jacketed autoclave for processing organic chemicals at 2,000 psi and 300°F. (Source: D. B. Gooch, “Autoclaves Pressure— Temperature Reactions,” Ind. Eng. Chem., 35, 927–946, 1943. Used with permission from the American Chemical Society.)
Industrial and Laboratory Reactors
225
Figure 4-4. A semi-batch reactor with outside circulation.
circumstances, reactions are sometimes performed under semi-batch conditions. This means that one or more reagents that do not react are completely entered in a vessel and the final reagent is then added under controlled conditions. No product is withdrawn until the entire reagent has been added and the reaction has proceeded to the required k extent. As an example, consider the reaction A + B 1 → C , where the reactor is first charged with reagent A and later reagent B is added continuously until the reaction is complete. Examples of this reaction process are:
226
Modeling of Chemical Kinetics and Reactor Design
• Reaction of a gas with a liquid where the gas bubbles through the liquid. • Reaction of a highly reactive substance with a relatively inert substance where the reactive substance, if present in large amounts at the beginning of the reaction, either polymerize or decompose. A semi-batch reactor has the same disadvantages as the batch reactor. However, it has the advantages of good temperature control and the capability of minimizing unwanted side reactions by maintaining a low concentration of one of the reactants. Semi-batch reactors are also of value when parallel reactions of different orders occur, where it may be more profitable to use semi-batch rather than batch operations. In many applications semi-batch reactors involve a substantial increase in the volume of reaction mixture during a processing cycle (i.e., emulsion polymerization).
CONTINUOUS FLOW ISOTHERMAL PERFECTLY STIRRED TANK REACTOR A continuous flow stirred tank reactor (CFSTR) differs from the batch reactor in that the feed mixture continuously enters and the outlet mixture is continuously withdrawn. There is intense mixing in the reactor to destroy any concentration and temperature differences. Heat transfer must be extremely efficient to keep the temperature of the reaction mixture equal to the temperature of the heat transfer medium. The CFSTR can either be used alone or as part of a series of battery CFSTRs as shown in Figure 4-5. If several vessels are used in series, the net effect is partial backmixing. It is easy to maintain good temperature control with a CFSTR. However, a disadvantage is that the conversion of reactant per volume of reactor is the smallest of the flow reactors. Therefore, very large reactors in series are needed to achieve high conversions. For example, the first reactor could be run to give a 50% conversion, yielding a high rate of reaction and subsequently reducing the total reactor volume. The next reactor might run from 50%–80% conversion and the third from 80%–90% until the desired conversion is reached. The effect of this process is a continuous reaction system that has a much lower volume, but has more equipment items because of the reactor vessels required. Industrial reactors operate in the steady state with the volume, concentration, and temperature of the reaction mixture being constant
Industrial and Laboratory Reactors
227
Figure 4-5. A battery of continuous flow stirred tank reactors.
with time. It is approximated that a steady state operation is reached when about five to ten times the reactor volume of the reaction mixture has passed through the reactor. In the continuously flow stirred tank reactor, the reaction takes place at the temperature and the degree of conversion of the outlet stream. This gives the reactor its characteristic features from either the batch or semi-batch reactor. Figure 4-6 is a variation of the continuous homogeneous reactor (baffled tank) in which backmixing has a considerable effect. The advantage of this type of reactor is its low cost per unit volume. It is often used when a long holding time would require a tubular reactor that is too long or too expensive. Agitation is not required and a high degree of backmixing is not harmful to the yield.
CONTINUOUS ISOTHERMAL PLUG FLOW TUBULAR REACTOR The plug flow tubular reactor is a heat exchanger where the reaction occurs in the tubes. Construction is often varied. For example, the reactor may consist of a tube placed in a bath, a tube in a jacket, or a number of tubes immensed in a heat transfer medium for the reactor
Modeling of Chemical Kinetics and Reactor Design
Figure 4-6. Baffled tank reactor.
228
Industrial and Laboratory Reactors
229
to operate isothermally. The exchange of heat between the reaction mixture and the medium must be so intense so as to heat the reaction mixture instantaneously and eliminate the effect of the reaction heat. The heat transfer medium must flow through the jacket in excess to keep its temperature unaffected by the reaction heat. Plug flow is an idealized flow of fluids where all particles in a given cross-section have identical velocity and direction of motion. During plug flow, particles of different age do not mingle and there is no backmixing. All particles that enter the reactor at the same time must leave simultaneously. The essential features of the plug flow reactor require that there be no longitudinal mixing of fluid elements as they move through the reactor, and that all fluid elements take the same length of time to move from the reactor inlet to the outlet. The plug flow can be described as a piston flow model. This is because the reaction occurring within differentially thin slugs of fluid, fill the entire cross-section of the tube and are separated from one another by hypothetical pistons that prevent axial mixing. These plugs of material move as units through the reactor, with the assumption that the velocity profile is flat as the fluid traverses the tube diameter. Each plug of fluid is assumed to be uniform in temperature, composition, and pressure and thus can be assumed that radial mixing is infinitely rapid. The tubular plug flow reactor is relatively easy to maintain with no moving parts, and it usually produces the highest conversion per reactor volume of any of the flow reactors. Other advantages are: • High throughput. • Little or no backmixing. • Close temperature control. The disadvantages are: • Expensive instrumentation. • High operating cost (maintenance, cleaning). • Nonuniform heat flux of the radiant section of furnace. The principal disadvantage of the tubular reactor is the difficulty in controlling the temperature within the reactor. This often results in hot spots especially when the reaction is exothermic. The tubular reactor can be in the form of one long tube or one of a number of shorter reactors arranged in a tube bank (Figure 4-7).
230
Modeling of Chemical Kinetics and Reactor Design
Figure 4-7. Longitudinal tubular reactor.
CONTINUOUS MULTIPHASE REACTORS Figure 4-8 shows a continuous reactor used for bubbling gaseous reactants through a liquid catalyst. This reactor allows for close temperature control. The fixed-bed (packed-bed) reactor is a tubular reactor that is packed with solid catalyst particles. The catalyst of the reactor may be placed in one or more fixed beds (i.e., layers across the reactor) or may be distributed in a series of parallel long tubes. The latter type of fixed-bed reactor is widely used in industry (e.g., ammonia synthesis) and offers several advantages over other forms of fixed beds.
Industrial and Laboratory Reactors
Figure 4-8. Heterogeneous continuous reactor.
231
232
Modeling of Chemical Kinetics and Reactor Design
Figure 4-9. Longitudinal catalytic fixed-bed reactor.
The type of reactor shown in Figure 4-9 is used in a heterogeneous reaction system involving catalyzed gas reactions. The fixed-bed reactor gives less chance for backmixing, but channeling of the gas flow through the catalyst bed causes ineffective use of parts of the reactor bed. An advantage of the fixed-bed reactor is that for most reactions, it gives the highest conversion per weight of catalyst of any catalytic reactor. Another advantage is it provides large volumes of processed reactants. The disadvantages are: • The catalysts are highly prone to deactivation. • The catalysts often require regeneration after a relatively short period of operation. This may incur additional cost. • It is difficult to control the heat-transfer in the catalyst bed. • Some part of the catalyst surface remains unused as a result of the reaction system and the rate-controlling step.
FLUIDIZED BED SYSTEM The fluidized bed in Figure 4-10 is another common type of catalytic reactor. The fluidized bed is analogous to the CFSTR in that its contents though heterogeneous are well mixed, resulting in an even temperature distribution throughout the bed. In a fluidized bed reactor, the solid material in the form of fine particles is contained in a vertical cylindrical vessel. The fluid stream
Industrial and Laboratory Reactors
233
Figure 4-10. Fluid catalytic cracking unit.
is passed up through the particles at a rate strong enough for them to lift and not fall back into the fluidized phase above its free surface by carryover in the fluid stream. The bed of particles in this state shows the appearance of boiling. In heterogeneous catalytic reactions, the catalyst loses its activity with operating time.
234
Modeling of Chemical Kinetics and Reactor Design
FLUID CATALYTIC CRACKING (FCC) UNIT The fluid catalytic cracking (FCC) process, as shown in Figure 410, converts straight-run atmospheric gas oil, vacuum gas oils, and heavy stocks recovered from other operations into high-octane gasoline, light fuel oils, slurry oil, and olefin-rich light gases. These products undergo further processing and separation in the FCC unit main fractionator and other vessels downstream of the FCC reactor. The gasoline produced has good overall octane characteristics and an excellent octane number. The catalysts used are mixtures of crystalline alumina silicates (known as zeolites), active alumina, silica-alumina, clay, and rare earth oxides. In the FCC, an oil feed composed of heavy hydrocarbon molecules is mixed with catalyst and enters a fluidized bed reactor. The long molecules react on the surface of the catalyst and are cracked into lighter product molecules (e.g., gasoline), which leave the reactor from the top. During the cracking process, carbon and other heavy uncracked organic materials are deposited on the surface of the catalyst resulting in its deactivation. The catalyst is then taken into a regenerator where the deposited surface material is burned with air. The regenerated catalyst returns to the reactor after it has been mixed with fresh feed. The activity of the newer catalysts is so intense that much of the cracking takes place in the line returning the regenerated catalyst to the reactor. This process is referred to as the transfer line cracking. A salient feature of the fluidized bed reactor is that it operates at nearly constant temperature and is, therefore, easy to control. Also, there is no opportunity for hot spots (a condition where a small increase in the wall temperature causes the temperature in a certain region of the reactor to increase rapidly, resulting in uncontrollable reactions) to develop as in the case of the fixed bed reactor. However, the fluidized bed is not as flexible as the fixed bed in adding or removing heat. The loss of catalyst due to carryover with the gas stream from the reactor and regenerator may cause problems. In this case, particle attrition reduces their size to such an extent where they are no longer fluidized, but instead flow with the gas stream. If this occurs, cyclone separators placed in the effluent lines from the reactor and the regenerator can recover the fine particles. These cyclones remove the majority of the entrained equilibrium size catalyst particles and smaller fines. The catalyst fines are attrition products caused by
Industrial and Laboratory Reactors
235
the collision of catalyst particles with each other and the reactor walls. These fines can escape capture in the cyclones because the removal efficiency of cyclones for particles of uniform density decreases with decreasing particle size. The catalyst fines captured in the reactor cyclones are transferred to the catalyst regenerator. Here, the fines are carried with the exhausted air and combustion products known as fuel gas. Most of the fine catalyst particles that are entrained in the flue gas are first captured in a two-stage cyclone within the regenerator vessel and then returned to the catalyst bed. Coker [1] illustrated the design of a cyclone separator, which is an economical device for removing particulate solids from a fluid system. Cyclone separators have been successfully employed in catalytic cracker operations. Designing cyclones often requires a balance between the desired collection efficiency, pressure drop, space limitations, and installation cost. The advantages of the fluidized bed are: • Savings in operating expenses due to heat recovery in the reactionregeneration steps. • Rapid mixing of reactants-solids and high heat transfer rates. • Easy to control both the heat transfer and the fluid flow system. The disadvantages are: • Backmixing due to particle distribution in dense and dilute phases. • Inefficient contacting due to solids movement and the bypassing of solids by bubbles. • Possible channeling, slugging, and attrition of catalyst. • Possible agglomeration and sintering of fine particles in the dilute phase under certain conditions (e.g., high temperature). The advantages of the ease of catalyst replacement or regeneration are offset by the high cost of the reactor and catalyst regeneration equipment.
DEEP CATALYTIC CRACKING UNIT An improved FCC unit is the deep catalytic cracking unit (DCC) that is designed to produce gasoline from vacuum gas oil (VGO). The
236
Modeling of Chemical Kinetics and Reactor Design
DCC uses heavy VGO as feedstock and has the same features has the FCC but with the following differences: special catalyst, high catalystto-oil ratio, higher steam injection rate, operating temperature, residence time, and lower operating pressure. In the DCC unit, the hydrocarbon feed is dispersed with steam and cracked using a hot solid catalyst in a riser, and enters a fluidized bed reactor. A known injection system is employed to achieve the desired temperature and catalyst-to-oil contacting. This maximizes the selective catalytic reactions. The vaporized oil and catalyst flow up the riser to the reactor where the reaction conditions can be varied to complete the cracking process. The cyclones that are located in the top of the reactor effect the separation of the catalyst and the hydrocarbon vapor products. The steam and reaction products are discharged from the reactor vapor line and enter the main fractionator where further processing ensure the separation of the stream into valuable products. The formed coke on the catalyst particles during cracking reduces its activity and selectivity. The spent catalyst passes into a stripping zone where steam is used to displace the entrained and adsorbed hydrocarbons, which leave the reactor with the products. Stripped catalyst particles are transported into the regenerator where the particles are contacted with air under controlled conditions. The regeneration process is the same as in the FCC unit. The DCC has been shown to produce polymer grade propylene from heavy gas oils, and it produces three and a half times more propylene and less than half the gasoline than a conventional FCC unit. Figure 4-11 illustrates a DCC unit and Figure 4-12 represents a typical DDC plant that produces propylene, which is integrated to a petrochemical complex. Table 4-1 compares the operating variables of the deep catalytic cracking (DCC), fluidized catalytic cracking (FCC) and steam cracking (SC) units. Another classification involves the number of phases in the reaction system. This classification influences the number and importance of mass and energy transfer processes in the design. Consider a stirred mixture of two liquid reactants A and B, and a catalyst consisting of small particles of a solid added to increase the reaction rate. A mass transfer resistance occurs between the bulk liquid and the surface of the catalyst particles. This is because the small particles tend to move with the liquid. Consequently, there is a layer of stagnant fluid that surrounds each particle. This results in reactants A and B transferring through this layer by diffusion in order to reach the catalyst surface. The diffusion resistance gives a difference in concentration between
Industrial and Laboratory Reactors
237
Figure 4-11. Deep catalytic cracking process flow diagram. (Courtesy of Stone & Webster Engineering Corporation, © 1977 Stone & Webster Engineering Corporation.)
Table 4-1 Operating parameters
Item Typical Residence Time (sec) Catalyst/Oil Steam, wt% of feed Reactor Temperature, °F Pressure, psig
Deep Catalytic Cracking (DCC)
Fluidized Catalytic Cracking (FCC)
10–60 9–15 10–30 950–1,070 10–20
1–30 5–10 1–10 950–1,020 15–30
Steam Cracking (SC) 0.1–0.2 30–80 1,400–1,600 15
the bulk fluid and the catalyst surface. The developing rate expression is used to account for the intrinsic kinetics at the catalyst surface and the mass transfer process. The coupling of the intrinsic kinetics and mass transfer is due to the heterogeneous nature of the system. In contrast to reactors involving the use of solid catalyst phases, there are reactors that use two liquid phases. An example is the
Figure 4-12. DCC plant petrochemicals integration. (Courtesy of Stone & Webster Engineering Corporation, © 1977 Stone & Webster Engineering Corporation.)
238 Modeling of Chemical Kinetics and Reactor Design
Industrial and Laboratory Reactors
239
catalytic alkylation reaction of an olefin (e.g., butylene) with isobutane to give C8-isomers (alkylate). Here, the two liquid hydrocarbon streams enter the bottom of the tubular flow vessel as shown in Figure 4-13. They are then dispersed as bubbles in a co-current continuous stream of liquid hydrofluoric acid (HF) that acts as a catalyst. Phase separation occurs at the top of the reactor where the lighter alkylate product is removed, and the heavier HF stream is recycled to the bottom of the reactor. In this case, the reaction occurs when both the olefin and isobutane reach the acid. This results in interphase mass transfer and the kinetics of the reaction in the acid phase. Tubular reactors are used for reactions involving a gas and a liquid. In this arrangement, the gas phase is dispersed as bubbles at the bottom of a tubular vessel. The bubbles then rise through the continuous liquid phase that flows downwards as shown in Figure 4-14. An example of this process is the removal of organic pollutants from water by noncatalytic oxidation with pure oxygen.
Figure 4-13. Liquid-liquid heterogeneous tubular flow reactor (e.g., alkylation of olefins and isobutane). (Source: J. M. Smith, Chemical Engineering Kinetics, 3rd ed., McGraw-Hill, Inc., 1981.)
240
Modeling of Chemical Kinetics and Reactor Design
Figure 4-14. A two-phase tubular flow reactor (e.g., gas-liquid bubble reactor for oxidation of pollutants in water). (Source: J. M. Smith, Chemical Engineering Kinetics, 3rd ed., McGraw-Hill, Inc. 1981.)
The effect of physical processes on reactor performance is more complex than for two-phase systems because both gas-liquid and liquid-solid interphase transport effects may be coupled with the intrinsic rate. The most common types of three-phase reactors are the slurry and trickle-bed reactors. These have found wide applications in the petroleum industry. A slurry reactor is a multi-phase flow reactor in which the reactant gas is bubbled through a solution containing solid catalyst particles. The reactor may operate continuously as a steady flow system with respect to both gas and liquid phases. Alternatively, a fixed charge of liquid is initially added to the stirred vessel, and the gas is continuously added such that the reactor is batch with respect to the liquid phase. This method is used in some hydrogenation reactions such as hydrogenation of oils in a slurry of nickel catalyst particles. Figure 4-15 shows a slurry-type reactor used for polymerization of ethylene in a slurry of solid catalyst particles in a solvent of cyclohexane.
Industrial and Laboratory Reactors
241
Figure 4-15. A slurry-type reactor (e.g., for C2H4 polymerization). (Source: J. M. Smith, Chemical Engineering Kinetics, 3rd ed., McGraw-Hill, Inc., 1981.)
A heterogeneous tubular reactor that incorporates three phases where gas and liquid reactants are contacted with the solid catalyst particles, is classified as a trickle-bed reactor. The liquid is usually allowed to flow down over the bed of catalyst, while the gas flows either up or down through the void spaces between the wetted pellets. Co-current downflow of the gas is generally preferred because it allows for better distribution of liquid over the catalyst bed and higher liquid flow rates are possible without flooding. In most applications, the reaction occurs between a dissolved gas and a liquid-phase reactant in the presence of a solid catalyst. In some cases, the liquid is an inert medium and the reaction takes place between the dissolved gases at the solid surface. These reactors have many diverse applications in catalytic processes and are used extensively in the chemical industry. Trickle-bed reactors have been developed by the petroleum industry for hydrodesulfurization, hydrocracking, and hydrotreating of various petroleum fractions of relatively high boiling point. Under reaction conditions, the hydrocarbon feed is frequently a vapor-liquid mixture that reacts at liquid hourly space velocities (LHSV in volume of fresh feed, as liquid/volume of bed, hr) in the
242
Modeling of Chemical Kinetics and Reactor Design
range of 0.5–4, as in the case of hydrodesulfurization shown in Figure 4-16. Unlike the slurry reactor, a trickle-bed reactor approaches plug flow behavior and, therefore, the problem of separating the catalyst from the product stream does not exist. The low ratio of liquid to catalyst in the reactor minimizes the extent of homogeneous reaction. However,
Figure 4-16. Trickle-bed (tubular reactor) for hydrodesulfurization. (Source: J. M. Smith, Chemical Engineering Kinetics, 3rd ed., McGraw-Hill, Inc., 1981.)
Industrial and Laboratory Reactors
243
if the reaction is substantially exothermic, the evolved heat may cause portions of the bed not to be wetted resulting in poor contacting of catalyst and liquid. Satterfield [2], Ramanchandran, and Chaudhari [3] have given detailed design procedures of three-phase catalytic reactors. Table 4-2 shows the various applications of these reactors.
DETERMINING LABORATORY REACTORS The success of designing industrial reactors greatly depends on accurate and reliable laboratory data. These data are derived from the Table 4-2 Applications of three-phase reactors 1. Slurry Reactor (A) Hydrogenation of: • fatty acids over a supported nickel catalyst. • 2-butyne-1,4-diol over a Pd − CaCO 3 catalyst. • glucose over a Raney nickel catalyst. (B) Oxidation of: • C2H4 in an inert liquid over a PdCl2-carbon catalyst. • SO2 in inert water over an activated carbon catalyst. (C) Hydroformation of CO with high-molecular weight olefins on either a cobalt or ruthenium complex bound to polymers. (D) Ethynylation: Reaction of acetylene with formaldehyde over a CaCl2supported catalyst.
2. Trickle Bed Reactors (A) Hydrodesulfurization: Removal of sulfur compounds from crude oil by reaction with hydrogen on C0 – Mo on alumina. (B) Hydrogenation of: • aniline over a Ni-clay catalyst. • 2-butyne, 1,4-diol over a supported Cu – Ni catalyst. • benzene, α – CH3 styrene, and crotonaldehyde. • aromatics in napthenic lube oil distillate. (C) Hydrodenitrogenation of: • lube oil distillate. • cracked light furnace oil. (D) Oxidation of: • cumene over activated carbon. • SO2 over carbon. Source: C. N. Satterfield, AIChE J., 21, 209 (1975); P. A. Ramachandran and R. V. Chaudari, Chem. Eng., 87 (24), 74 (1980); R. V. Chaudari and P. A. Ramachandran, AIChE J., 26, 177 (1980).
244
Modeling of Chemical Kinetics and Reactor Design
reaction kinetic study from laboratory reactors, which are useful in scale-up. The design and construction of laboratory and pilot plant reactors together with experimental programs can be both time consuming and expensive, therefore it is imperative that the correct choice of laboratory reactor be used. Weekman [4] presented an excellent review on the choice of various laboratory reactors. The criteria employed to determine the various types of these reactors are listed in Table 4-3. Sampling of a two-fluid phase system containing powdered catalyst can be problematic and should be considered in the reactor design. In the case of complex reacting systems with multiple reaction paths, it is important that isothermal data are obtained. Also, different activation energies for the various reaction paths will make it difficult to evaluate the rate constants from non-isothermal data. Measurements of the true reaction times are sometimes difficult to determine due to the two-phase nature of the fluid reactants in contact with the solid phase. Adsorption of reactants on the catalyst surface can result in catalyst-reactant contact times that are different from the fluid dynamic residence times. Additionally, different velocities between the vapor, liquid, and solid phases must be considered when measuring reaction times. Various laboratory reactors and their limitations for industrial use are reviewed below. DIFFERENTIAL REACTOR The differential reactor is used to evaluate the reaction rate as a function of concentration for a heterogeneous system. It consists of a tube that contains a small amount of catalyst as shown schematically in Figure 4-17. The conversion of the reactants in the bed is extremely small due to the small amount of catalyst used, as is the change in reactant concentration through the bed. The result is that the reactant concentration through the reactor is constant and nearly equal to the Table 4-3 Criteria used to determine laboratory reactors 1. 2. 3. 4. 5.
Ease of sampling and product composition analysis. Degree of isothermality. Effectiveness of contact between catalyst and reactant. Handling of catalyst decay. Ease of construction and cost.
Industrial and Laboratory Reactors
245
Figure 4-17. Differential reactor. (Source: V. W. Weekman, “Laboratory Reactors and Their Limitations,” AIChEJ, Vol. 20, p. 833, 1974. Used with permission of the AIChEJ.)
inlet concentration. Therefore, the reactor is considered gradientless, and the reaction rate is spatially uniform in the bed. Because of the small conversion, heat release is also small, and the reactor operates in an isothermal manner. The differential reactor is simple to construct and inexpensive. However, during operation, care must be taken to ensure that the reactant gas or liquid does not bypass or channel through the packed catalyst, but instead flows uniformly across the catalyst. This reactor is a poor choice if the catalyst decays rapidly, since the rate of reaction parameters at the start of a run will be different from those at the end of the run. FIXED BED (INTEGRAL) REACTOR Advantages of the fixed bed reactors are its ease of construction, good sampling and product analysis, higher conversions, and no catalyst or product separation problems. Rapid sampling that provides instantaneous data during catalyst decay may cause channeling or bypassing of some of the catalyst by the reactant stream. This can be minimized by careful attention to the distribution of the liquid and gas. The main problem with the fixed bed design is achieving uniform isothermal temperatures. Significant axial and radial temperature gradients can result with severe exothermic or endothermic reactions. Different products are formed at different reaction paths. This results in changes in the reaction mechanism with changing temperature along the length of the reactor and, consequently, makes it difficult to evaluate the various reaction rate constants. If the catalyst decays during the experiment, the reaction rates will be significantly different at the end of the experiment than at the
246
Modeling of Chemical Kinetics and Reactor Design
beginning. Also, the reaction may follow different reaction paths as the catalyst decays, thereby varying the selectivity of a particular product. The fixed bed reactor is relatively easy and inexpensive to construct (Figure 4-18). STIRRED BATCH REACTOR (SBR) The stirred batch reactor contains catalyst dispersed as slurry. There is better contact between the catalyst and the fluid in this reactor than with either the differential or integral reactors. Separation of the product from the catalyst must be accomplished by the sampling system, which can be a problem. Samples of fluids are usually passed through cyclones or withdrawn through filters or screens to separate the catalyst and fluid, consequently stopping the reaction. Due to sufficient mixing, isothermality is good and accurate residence time measurements should be possible. Since all three phases are contained in the reactor, it may provide the most accurate measurement of contact time of all reactors provided the reaction can be rapidly quenched at the end of the experiment. The decaying of the catalyst poses the same problem as with the fixed bed reactor. Consequently, the activity and selectivity will vary during the course of data collection. The stirred batch reactor (Figure 4-19) is fairly simple to construct at a reasonable cost. STIRRED CONTAINED SOLIDS REACTOR (SCSR) Figure 4-20 shows a typical design of a stirred contained solids reactor. Here, the catalyst particles are mounted in the paddles that
Figure 4-18. Fixed bed (integral) reactor. (Source: V. W. Weekman, “Laboratory Reactors and Their Limitations,” AIChEJ, Vol. 20, p. 833, 1974. Used with permission of the AIChEJ.)
Industrial and Laboratory Reactors
247
Figure 4-19. Stirred batch reactor. (Source: V. W. Weekman, “Laboratory Reactors and Their Limitations,” AIChEJ, Vol. 20, p. 833, 1974. Used with permission of the AIChEJ.)
rotate at high speeds to minimize external mass transfer effects, and also maintain well-mixed fluid contents. This type of operation provides good isothermal conditions, which can be maintained, and there is good contact between the catalyst and the fluid. However, if the catalyst particle size is small, there may be difficulties in containing the particles in the paddle screens. This reactor rates well in ease of sampling and analysis of the product composition. The residence time of the solid is accurately known and, with good mixing, the gas-vapor residence times can also be measured quite accurately. The disadvantage of this type of reactor is its unsteady state, which can affect its selectivity. However, it is unable to generate useful data when the catalyst being studied decays.
248
Modeling of Chemical Kinetics and Reactor Design
Figure 4-20. Stirred contained solids reactor. (Source: V. W. Weekman, “Laboratory Reactors and Their Limitations,” AIChEJ, Vol. 20, p. 833, 1974. Used with permission of the AIChEJ.)
CONTINUOUS STIRRED TANK REACTOR (CSTR) In this reactor (Figure 4-21), the catalyst is charged to the reactor together with the fluid feed, and the catalyst leaves the reactor in the product stream at the same rate that it is charged into the reactor. The catalyst in the reactor maintains the same level of catalytic activity at all times. However, as with the stirred batch reactors, the catalyst slurry in the reactor presents some sampling problems. This requires either quenching or rapidly separating the catalyst from the reaction mixture, otherwise the sample may continuously react at different temperatures as it cools, disguising the selectivity behavior. Since the reactor is well mixed, isothermality and fluid solid contact are good. The reactor operates in the steady state because catalyst and reactants are continuously added, which eliminates any possible catalyst decay selectivity disguise. STRAIGHT-THROUGH TRANSPORT REACTOR (STTR) The transport reactor (Figure 4-22) is widely used in the production of gasoline from heavier petroleum fractions. In this reactor, either an
Industrial and Laboratory Reactors
249
Figure 4-21. Continuous stirred tank reactor. (Source: V. W. Weekman, “Laboratory Reactors and Their Limitations,” AIChEJ, Vol. 20, p. 833, 1974. Used with permission of the AIChEJ.)
inert carrier gas or the reactant itself transports the catalyst through the reactor. Since the catalyst passes through with the reactant, it is necessary to achieve either rapid quenching or rapid catalyst reactant separation. The possibility of catalyst decay selectivity disguise is completely eliminated because the catalyst and reactants are continuously fed. For highly endothermic or exothermic reactions, isothermal operation is difficult to achieve, hence, a poor-to-fair rating in this category. For high velocities where there is little slip between the catalyst and reactant phases, there are accurate measurements of residence time. At lower velocities, there may be slip between the phases that can lead to difficulties in accurately determining the contact time. Since the transport reactors are a length of tubing, they are easier to construct, but salt or sand baths may be required in order to maintain isothermal operation. Additionally, the construction rating is fair-to-good because product-catalyst separation facilities are required. RECIRCULATING TRANSPORT REACTOR (RTR) Adding a recirculating loop to the transport reactor, a well-mixed condition is achieved provided the recirculation rate is large with
250
Modeling of Chemical Kinetics and Reactor Design
Figure 4-22. Straight-through transport reactor.
respect to the feed rate (Figure 4-23). Isothermal operation is attained due to this well-mixed condition. Since the reactor is operated at a steady state, the kinetic parameters measured at the beginning of the experiment will be the same as those measured at the end. Because fresh catalyst is mixed with decayed catalyst from the recycle, the product distribution and the kinetic parameters may not be the same as those measured in a straight-through transport reactor where the gas
Industrial and Laboratory Reactors
251
Figure 4-23. Recirculationg transport reactors. (Source: V. W. Weekman, “Laboratory Reactors and Their Limitations,” AIChEJ, Vol. 20, p. 833, 1974. Used with permission of the AIChEJ.)
252
Modeling of Chemical Kinetics and Reactor Design
contacts only fresh catalyst. The recirculation further provides more complexity to the construction, which gives it a lower rating. PULSE REACTOR In the pulse reactor, a small pulse of reactant is charged with a small amount of catalyst. The product from the reactor is directly fed to a chromatograph to minimize sampling problems (Figure 4-24). A wide range of conversion levels can be achieved so sampling and analysis of product composition do not pose a serious problem. A small amount of catalyst can be surrounded by a large heat sink to minimize its deviation from isothermal operation. However, high exothermic or endothermic reactions can result in significant temperature difference. The difficulty with the pulse reactor is the change in the catalyst surface concentrations during the pulse. Consequently, the adsorbed species change during the course of the reaction, which could lead to selectivity disguise. However, if all the reaction paths are identically altered by these adsorbed species, then the pulse reactor may be useful for selectivity studies. This is an unsteady state reactor and short pulses of reactant can follow the instantaneous behavior, resulting in a fairto-good rating. The problems in construction are identical to the differential reactor and are slightly compounded by the need to introduce accurate pulses of reactant. Table 4-4 summarizes the ratings of the various reactors. The CFSTR and the recirculating transport reactor are the best choices because they are satisfactory in every category except for construction. The stirred batch and contained solid reactors are satisfactory if the catalyst under study does not decay. If the system is not limited by internal diffusion in the catalyst pellet, larger pellets could be used and the stirred-contained solids reactor is the better choice. However,
Figure 4-24. Pulse reactors. (Source: V. W. Weekman, “Laboratory Reactors and Their Limitations,” AIChEJ, Vol. 20, p. 833, 1974. Used with permission of the AIChEJ.)
P-F G F G F F-G F-G G F-G P-F G G G P-F G F-G
Isothermality F F G F-G F-G F-G G P
Solid contact
P P P P F-G G F-G F-G
Fluiddecaying catalyst
G G G F-G P-F F-G P-F G
Ease of construction
G = good, F = fair, P = poor. Source: V. W. Weekman, “Laboratory Reactors and Their Limitations”, AIChEJ, Vol. 20, p. 833, 1974. Used with permission of the AIChEJ.
Differential Fixed bed Stirred batch Stirred-contained solids Continuous flow stirred tank Straight-through transport Recirculating transport Pulse
Reactor type
Sampling and analysis
Table 4-4 Summary of reactor ratings, gas-liquid, powdered catalyst, decaying catalyst system
Industrial and Laboratory Reactors 253
254
Modeling of Chemical Kinetics and Reactor Design
if the catalyst is non-decaying and heat effects are negligible, the fixed bed (integral) reactor is the best choice because of its ease of construction and operation. The pulse reactor is most satisfactory in systems that do not strongly adsorb or where the adsorbed species do not relatively alter the reaction paths. In cases where the reaction system is extremely critical, more than one reactor type is used in determining the reaction rate law parameters. LOOP REACTORS A loop reactor is a continuous steel tube or pipe, which connects the outlet of a circulation pump to its inlet. Reactants are fed into the loop, where the reaction occurs, and product is withdrawn from the loop. Loop reactors are used in place of batch stirred tank reactors in a variety of applications including chlorination, ethoxylation, hydrogenation, and polymerization. A loop reactor is typically much smaller than a batch reactor producing the same amount of product. Mass transfer is often the rate-limiting step in gas-liquid reactions, and a loop reactor design increases mass transfer, while reducing reactor size and improving process yields. An example is an organic material that has been chlorinated in a glass-lined batch stirred tank reactor, with chlorine fed through a dip pipe. Replacing the stirred tank reactor with a loop reactor, with chlorine fed to the recirculating liquid stream through an eductor, reduced reactor size, increased productivity, and reduced chlorine usage. Figure 4-25 shows a schematic of a loop reactor system. Table 4-5 compares the advantages of a loop reactor to a batch stirred tank reactor.
GUIDELINES FOR SELECTING BATCH PROCESSES Douglas [5] gives an excellent review in selecting a batch process in favor of a continuous process. The factors that favor batch operations are summarized as follows: • Production rates: — Sometimes batch process, if the plants have production capacity less than 10 × 106 lb/yr (5 × 106 kg/hr). — Usually batch process, if the plants have production capacity less than 1 × 106 lb/yr (0.5 × 106 kg/hr). — Where multiproduct plants are produced using the same processing equipment.
Industrial and Laboratory Reactors
255
Figure 4-25. A loop reactor production system. (Source: M. Wilkinson and K. Geddes, “An Award Winning Process.” Chemistry in Britain, December, 1050–1052, 1993.)
• Market forces: — Where products are seasonal (e.g., fertilizers). — Short product lifetime (e.g., organic pigments). • Operational problems: — Long reaction times (i.e., when chemical reactions are slow). — Handling slurries at low flowrates. — Rapidly fouling materials (e.g., materials foul equipment so rapidly that shutdown and frequent cleaning are required).
256
Modeling of Chemical Kinetics and Reactor Design
Table 4-5 Effect of reactor design on size and productivity for a gas-liquid reaction Reactor type Reactor size (l) Chlorination time (hr) Productivity (kg/hr) Chlorine usage (kg/100 kg product) Caustic usage in vent scrubber (kg/100 kg product)
Batch stirred tank reactor
Loop reactor
8,000 16 370 33 31
2,500 4 530 22 5
Source: Center for Chemical Process Safety (CCPS). “Guidelines for Engineering Design for Process Safety.” New York: AIChE, 1993a.
Regardless of their inherent advantages and disadvantages, the choice of the proper design from any of the industrial reactors for a certain operation greatly depends on the specific reaction system. This involves an extensive study of many factors that contribute to the optimum. The performance of an industrial reactor also depends on performing the reaction at a number of scales to gain sufficient confidence to make the correct predictions. This may require predicting the effect of concentration and temperature on selectivity using a laboratory or pilot plant reactor, followed by predicting the temperature and mixing patterns on an industrial plant. This approach is much preferred in industry than the empirical scale-up method because only two types of reactors (laboratory and pilot plant) are needed. Greater options are available in the design of a full-scale reactor once the heat transfer and mixing characteristics are defined. Additionally, the criteria for similarity are essential between the laboratory and full-scale plant. The scale-up of reactors is covered in Chapter 13. The safety of controlling and operating chemical reactions and associated hazards form an essential aspect of chemical manufacture. The manufacture of various chemical products involves the processing of reactive chemicals that are toxic, explosive, or flammable. The principal types of reactors for processing organic reactions such as polymerization, sulphonation, nitration, halogenation, or alkylation are batch and semi-batch reactors. In these operations, the reactions are exothermic and may lead to overheating. As the temperature rises, reaction rates increase exponentially, which is characterized by progressive increases
Industrial and Laboratory Reactors
257
Table 4-6 Design guidelines for reactors 1. Single irreversible reactions (not autocatalytic) (A) Isothermal—always use a plug flow reactor (B) Adiabatic 1. Plug flow if the reaction rate monotonically decreases with conversion 2. CFSTR operating at the maximum reaction rate followed by a plug flow section
2. Single reversible reactions—adiabatic (A) Maximum temperature—adiabatic (B) A series of adiabatic beds with a decreasing temperature profile if exothermic
3. Parallel reactions-composition effects (A) For A → R (desired) and A → S (waste), where the ratio of the reaction a −a rates is rR rS = ( k 1 k 2 )C A1 2 1. If a1 > a2, keep CA high a. Use batch or plug flow b. High pressure, eliminate inerts c. Avoid recycle of products d. Can use a small reactor 2. If a1 < a2, keep CA low a. Use a CFSTR with a high conversion b. Large recycle of products c. Low pressure, add inerts (B) For A + B → R (desired) and A + B → S (waste), where the ratio of the a −a b −b rates is rR rS = ( k 1 k 2 ) C A1 2 C B1 2 1. If a1 > a2 and b1 > b2, both CA and C B high 2. If a1 < a2 and b1 > b2, then CA low, CB high 3. If a1 > a2 and b1 < b2, then CA high, C B low 4. If a1 < a2 and b1 < b2, both CA and C B low 5. See Figure 4-26 for various reactor configuration
4. Consecutive reactions-composition effects. (A) A → R (desired) and R → S (waste)—minimize the mixing of streams with different compositions.
5. Parallel reactions-temperature effects rR/rS = (k1/k2)f(CA, CB) (A) If E1 > E2, use a high temperature (B) If E1 < E2, use an increasing temperature profile k
k
2 →S 6. Consecutive reactions-temperature effects A 1 → R
(A) If E1 > E2, use a decreasing temperature profile—not very sensitive (B) If E1 < E2, use a low temperature Source: J. M. Douglas, Conceptual Design of Chemical Processes, McGraw-Hill, Inc., 1988.
258
Modeling of Chemical Kinetics and Reactor Design
in the generated heat rate. When the rate of heat generation is greater than the rate of heat absorbed, a thermal runaway will occur with disastrous consequences (as the incidents at Seveso and Bhopal have shown). A review of these incidents in batch reactors reveals the main causes are: • • • •
Inadequate control systems and safety backup systems. Inadequate operational procedures, including training. Inadequate engineering design for heat transfer. Inadequate understanding of the chemistry process and thermochemistry.
Figure 4-26. Parallel reactions. (Source: O. Levenspiel, Chemical Reaction Engineering, 2nd ed., Wiley, New York, 1972.)
Industrial and Laboratory Reactors
259
Analysis of thermal runaway reactions is reviewed in Chapter 12. Table 4-6 gives various guidelines for the design of reactors and Figure 4-26 illustrates various reactor configurations.
REFERENCES 1. Coker, A. K., “Understanding cyclone design,” Chem. Eng Progr, pp. 51–55, December 1993. 2. Satterfield, C. N., Mass Transfer in Heterogeneous Catalysis, MIT Press, Cambridge, Mass, 1970. 3. Ramachandran, P. A. and Chaudhari, R. V., Three Phase Catalytic Reactors, Gordon and Breach Science Publishers. 4. Weekman, V. W., “Laboratory Reactors and Their Limitations,” AIChEJ, Vol. 20, No. 5, pp. 833–839, 1974. 5. Douglas, J. M., Conceptual Design of Chemical Processes, McGrawHill, Inc., 1988. 6. Horak, J. and Pasek, J., Design of Industrial Chemical Reactors from Laboratory Data, Heyden & Son Ltd., 1978. 7. Smith, J. M., Chemical Engineering Kinetics, 3rd ed., McGraw-Hill Book Company, 1981.
260
Modeling of Chemical Kinetics and Reactor Design
CHAPTER FIVE
Introduction to Reactor Design Fundamentals for Ideal Systems INTRODUCTION In Chapter 4, the various types of laboratory and industrial reactors were reviewed. Reactor design is primarily concerned with the type and size of reactor and its method of operation for the required process. Important considerations are given at an early stage in the design of any process where chemical reaction is required. Designers must first consider the thermodynamics involving the equilibrium of reaction before investigating the chemical kinetics in relation to the reaction mechanisms. Figure 5-1 succinctly illustrates the logic of this approach. In this figure, consideration is given to the possibility of using either a gas phase or liquid phase reaction, whether the reaction is endothermic (i.e., absorbing heat) or exothermic (i.e., releasing heat), and whether or not the reaction is reversible. There are advantages to using the liquid phase rather than the gas phase operation. For example, for the desired product the reactor may be smaller. This is because the physical properties of liquids are greater than those for gases, namely the heat capacities and thermal conductivities, factors which increase the heat transfer. Additionally, the equipment size is small resulting in lower power requirements and capital costs. The main disadvantages are corrosion and catalyst losses. In considering a liquid system, all operating conditions must fall within the two-phase region. If the critical temperature is not significantly above the desired reaction temperature, high operating pressures are potentially hazardous and expensive to contain, especially if one of the reactants is a noncondensable gas, which is required at high partial pressure. 260
Introduction to Reactor Design Fundamentals for Ideal Systems
261
Figure 5-1. Flowchart for reactor design. (Source: R. Scott with N. Macleod, “Process Design Case Studies.” Used with permission of IChemE, 1992.)
In the case of thermodynamics, the designer can investigate the nature of the reaction heat and whether the reaction is reversible. If these exothermic reactions are irreversible, attention may be focused on the influence of reactor design on conversion and with heat transfer control. An objective of reactor design is to determine the size and type of reactor and mode of operation for the required job. The choice
262
Modeling of Chemical Kinetics and Reactor Design
of reactors depends on many factors such as safety, environment, and profit. Optimization techniques are often employed during the design stage to establish the optimum design from the profit viewpoint. This includes factors such as raw materials, initial and operating costs, and the market value of the finished products. The designer also requires knowledge of reactor performance before reviewing an optimization technique. Chemical reactions are performed in reactor systems that are derived from one of the following basic types of model reactors: • The well-mixed reaction system with uniform composition that is operated batchwise. • The semibatch reactor where the incoming and outgoing mass flows are not equal to each other, and the total mass of the reacting mixture is not constant. • The continuously operated stirred tank reaction in which the composition of the reaction mixture is assumed uniform and equal to the composition at the outlet. • The tubular (plug flow) reactor in which piston flow of the reacting mixture is assumed, and there is neither mixing nor diffusion in the flow direction. The following details establish reactor performance, considers the overall fractional yield, and predicts the concentration profiles with time of complex reactions in batch systems using the Runge-Kutta numerical method of analysis.
A GENERAL APPROACH The rate equation involves a mathematical expression describing the rate of progress of the reaction. To predict the size of the reactor required in achieving a given degree of conversion of reactants and a fixed output of the product, the following information is required: • • • • •
Composition changes Temperature changes Mixing patterns Mass transfer Heat transfer
Introduction to Reactor Design Fundamentals for Ideal Systems
263
Information on the composition and temperature changes is obtained from the rate equation, while the mixing patterns are related to the intensity of mixing and reactor geometry. Heat transfer is referred to as the exothermic or endothermic nature of the reactions and the mass transfer to the heterogeneous systems. GENERAL MASS BALANCE For the ideal reactors considered, the design equations are based on the mass conservation equations. With this in mind, a suitable component is chosen (i.e., reactant or product). Consider an element of volume, δV, and the changes occurring between time t and t + δt (Figure 5-2): Output Input + + = Accumulation − Appearance Disappearance by reaction by reaction
(5-1)
Figure 5-2. Material balance for a volume element of the reactor.
264
Modeling of Chemical Kinetics and Reactor Design
• Input: Includes the amount of reactant entering the system δV in δt by flow plus the amount of reactant formed by reaction in δV during δt. • Output: Includes the amount of reactant leaving δV in δt by flow plus the amount of reactant destroyed by reaction in δV during δt. • Accumulation: Is the amount of reactant in δV at (t + δt) minus the amount of reactant in δV at t. • Ideal reactors: Refers to the assumed mixing patterns in the reactor. • Perfect mixing: Describes the contents as so well mixed that both composition and temperature are uniform throughout the system. The term “perfect mixing” is unambiguous as it refers to instantaneous and complete mixing on the molecular scale. Realistically, no reactor can attain this ideal behavior just as no tubular reactor can achieve a true piston (plug) flow situation. However, it is possible to design reactors that closely approach these conditions. Fluid mixing, residence time distribution, and micro and macro scale are reviewed in Chapters 7 and 8.
IDEAL ISOTHERMAL REACTORS BATCH REACTORS A well-mixed batch reactor has no input or output of mass. The amounts of individual components may change due to reaction, but not because of flow into or out of the system. A typical batch reactor is shown in Figure 5-3. Consider a well-mixed batch reactor with a key reactant A, during time t to time t + δt, where δt is very small. For a well-mixed batch system, assume the following: • Perfect mixing • An isothermal operation • Fluid density is constant Rearranging the mass balance in Equation 5-1, gives
INPUT = No flow
OUTPUT No flow + Disappearance of A by reaction
ACCUMULATION + Concentration of A changes with time
Introduction to Reactor Design Fundamentals for Ideal Systems
265
Figure 5-3. The batch reactor.
Assume δVR to be VR (i.e., the volume of the fluid in the reactor), the total reactor volume. Suppose that at time t = 0, the number of moles of A in VR = NAO, and at time t = t, the number of moles of A in VR = NA. The rate of reaction (–rA) also varies with time t, since the concentration CA changes with time. Using Taylor’s series y = f(t), gives f ( t + δt ) = f ( t ) +
df ( t ) d 2 f ( t ) δt 2 δt + • + ..... 2 dt dt 2
(5-2)
when δt is small, terms containing δt become negligible. time Moles of A in VR Net rate of reaction of A
t NA (–rA)
t + δt dN A NA + δt + ..... dt
(− rA ) +
d( − rA ) dt
δt + ....
266
Modeling of Chemical Kinetics and Reactor Design
The average rate of reaction during δt is
(− rA )
+
1 d( − rA ) δt + ...... 2 dt
(5-3)
During δt, OUTPUT = ACCUMULATION
(t + δt ) − t dN A 1 d( − rA ) − ( − rA ) + δt VR • δt = N A + δt − N A dt 2 dt
(5-4)
dN A 1 d( − rA ) − ( − rA ) + δt VR = dt 2 dt
(5-5)
As δt → 0, the term 1/2[d(–rA)/dt] δt → 0, and Equation 5-5 becomes −( − rA ) VR =
dN A dt
(5-6)
Rearranging Equation 5-6 gives
(− rA ) = − V1
R
dN A dt
(5-7)
In terms of the fractional conversion XA
XA =
N AO − N A N AO
(5-8)
Rearranging Equation 5-8 gives
N A = N AO (1 − X A )
(5-9)
Differentiating Equation 5-9 gives
dN A = − N AO dX A
(5-10)
Introduction to Reactor Design Fundamentals for Ideal Systems
267
Substituting Equation 5-10 into Equation 5-7 gives
(− rA ) VR = N AO
dX A dt
(5-11)
Rearranging and integrating Equation 5-11 between the limits at t = 0, XA = 0 and at t = t, XA = XAF results in t
∫ dt = N AO
X AF
0
t = N AO
dX
∫ (− rA )AVR 0
X AF
dX
∫ (− rA )AVR 0
where the concentration C A =
(5-12) N A moles VR volume
(5-13)
The fractional conversion XA at constant volume is XA =
C AO − C A C AO
(5-14)
Substituting Equation 5-13 into Equation 5-11, rearranging and integrating between the limits at t = 0, XA = 0 and at t = t, XA = XAF yields t
X AF
dX
∫ dt = C AO ∫ (− rAA) 0 0 t = C AO
X AF
dX
∫ (− rAA) 0
(5-15)
(5-16)
Equation 5-16 is the time required to achieve a conversion XA for either isothermal or non-isothermal operation. Equation 5-16 can also be expressed in terms of concentration at constant fluid density as
268
Modeling of Chemical Kinetics and Reactor Design
t= −
C AF
dC
∫ (− rAA) = , C
for ε = 0
(5-17)
AO
Equations 5-12, 5-16, and 5-17 are the performance equations for a batch reactor. When the volume of reacting mixture changes proportionately with conversion, as in the case of gas phase reactions, this implies working volume changes with time,
and Equation 5-12 becomes VR = VO (1 + ε A X A )
(5-18)
where VO = initial volume of the reactor VR = volume at time t t = N AO
X AF
∫ 0
= C AO
N dX A = AO (− rA ) VO (1 + ε A X A ) VO
X AF
dX
∫ (− rA )(1 +Aε A X A ) 0
X AF
dX
∫ (− rA )(1 +Aε A X A ) 0 (5-19)
where εA is the fractional change in volume of the system between no conversion and complete conversion of reactant A given by εA =
VX A =1 − VX A = 0 VX A = 0
(5-20)
Introduction to Reactor Design Fundamentals for Ideal Systems
269
Batch reactors are charged with reactants, closed, and heated to the reaction temperature, which may be maintained (i.e., isothermally) for the duration of the reaction. After the reaction is completed, the mixture cooled, and the reactor opened, the product is discharged and the reactor is cleaned for the next batch. In industrial operations, the cycle time is constant from one batch to the next. The time required for filling, discharging, heating, cooling, and cleaning the reactor forms an integral part of the total batch cycle time (tb) and is referred to as the turnaround time (tt). The total batch cycle time tb is the reaction tr time plus the turnaround time tt. This is expressed as: tb = tr + tt
(5-21)
From these various estimates, the total batch cycle time tb is used in batch reactor design to determine the productivity of the reactor. Batch reactors are used in operations that are small and when multiproducts are required. Pilot plant trials for sales samples in a new market development are carried out in batch reactors. Use of batch reactors can be seen in pharmaceutical, fine chemicals, biochemical, and dye industries. This is because multi-product, changeable demand often requires a single unit to be used in various production campaigns. However, batch reactors are seldom employed on an industrial scale for gas phase reactions. This is due to the limited quantity produced, although batch reactors can be readily employed for kinetic studies of gas phase reactions. Figure 5-4 illustrates the performance equations for batch reactors. Following are examples for finding the time of an isothermal batch reactor for a given conversion of the reactant and other pertinent variables, and for gas phase reaction. Example 5-1
Consider an isothermal batch reactor for a given conversion of the reactant
aA + bB → cC + dD
(5-22)
where component A is the limiting reactant. The stoichiometric coefficients are: a = 1, b = 2, c = 1, and d = 0. The initial moles of components A, B, C, and D are NA = 0.001 gmol, NB = 0.003 gmol,
270
Modeling of Chemical Kinetics and Reactor Design
Figure 5-4. The performance equations for batch reactors.
NC = 0.0 gmol, ND = 0.0 gmol, respectively. A mixture of A and B is charged into a 1-liter reactor. Determine the holding time required to achieve 90% fractional conversion of A (XA = 0.9). The rate constant is k = 1.0 × 105[(liter)2/(gmol2 • min)] and the reaction is first order in A, second order in B and third order overall. Solution Assuming a constant volume batch system, from the stoichiometric coefficients of Equation 5-22
Introduction to Reactor Design Fundamentals for Ideal Systems k A + 2B →C
271
(5-23)
where component A is the limiting reactant. The material balance on component A in the batch reactor is
(− rA ) = − V1
R
dN A dt
(5-7)
where the concentration CA = NA/VR and the rate Equation 5-7 becomes
(− rA ) = −
dC A = kC A C 2B dt
(5-24)
The concentrations of A and B can be expressed in terms of the fractional conversion and the stoichiometry of the reaction as: Component
A
B
At time t = 0 At time t = t Amount reacted
CAO CA (CAO – CA)
CBO CB (CBO – CB)
From the stoichiometry,
2(C AO − C A ) = C BO − C B
(5-25)
The concentration of B is expressed as C B = C BO − 2(C AO − C A )
(5-26)
Using the fractional conversion XA at constant volume XA =
C AO − C A C AO
(5-13)
Therefore, the amount reacted
C AO − C A = C AO X A or
(5-27)
272
Modeling of Chemical Kinetics and Reactor Design
C A = C AO (1 − X A )
(5-28)
Differentiation of A in Equation 5-27 gives − dC A = C AO dX A
(5-29)
Substituting Equations 5-26, 5-28, and 5-29 into Equation 5-24 gives
C AO
{
}2
dX A = kC AO (1 − X A ) C BO − 2(C AO − C A ) dt = kC AO (1 − X A )(C BO − 2C AO X A )
C AO
2
(5-30) (5-31)
C dX A = kC AO (1 − X A )C AO BO − 2 X A dt C AO
2
dX A 2 = kC 2AO (1 − X A )(θ B − 2 X A ) dt
(5-32)
where θB = CBO/CAO. Rearranging Equation 5-32 and integrating between the limits t = 0, XA = 0, t = tholding time, XA = XAF=0.9 gives X A = 0.9
dX A
∫ (1 − X )(θ − 2X ) A B A
t = t holding time 2 2 = kC AO
X A=0
∫
dt
t=0
(5-33)
The integral on the left side of Equation 5-33 can be expressed by partial fraction to give 1
(1 − X A )(θB − 2 X A )
2
≡
A B C + + 1 − X A θ B − 2 X A (θ B − 2 X A ) 2
(5-34)
Rearranging Equation 5-34 gives 1 ≡ A(θ B − 2 X A ) + B(1 − X A )(θ B − 2 X A ) + C(1 − X A ) 2
Putting XA = 1 into Equation 5-35 gives 1 = A(θB – 2)2 or
(5-35)
Introduction to Reactor Design Fundamentals for Ideal Systems
A=
273
1
(θ B − 2 ) 2
(5-36)
Putting XA = 0 into Equation 5-35 gives 1 = Aθ 2B + Bθ B + C
(5-37)
Putting XA = θB/2 into Equation 5-35 yields θ 1 = C 1 − B 2
(5-38)
2 2 − θB
(5-39)
or
C=
Substituting Equations 5-36 and 5-39 into Equation 5-37 gives 1=
θ 2B
(θ B − 2 )
B= −
2
+ Bθ B +
2 (2 − θ B )
(5-40)
2 (θ B − 2 ) 2
(5-41)
The integral of Equation 5-34 between the limits becomes
I=
X A = 0.9
dX
∫ (1 − X )(θ A− 2X )2 A B A X A=0
=
XA
1
(θB − 2) ∫0 2
2 + (2 − θ B )
dX A 2 − 1 − XA (θ B − 2 ) 2
XA
dX
∫ (θ − 2XA )2 B A 0
XA
dX
∫ (θB − 2AX A ) 0 (5-42)
274
Modeling of Chemical Kinetics and Reactor Design
I=−
[ln(1 − X A )]0 (θ B − 2 ) 1
XA
2
1 1 + (2 − θB ) (θB − 2 X A )
+
[ln(θB − 2X A )]0 (θ B − 2 ) 1
XA
2
XA
(5-43) 0
or
1
(θ B − 2 ) 2
(θ B − 2 X A ) 2 X A (θ B − 2 ) ln = kC 2AO t holding time (5-44) − − − X X θ 1 θ θ 2 ( ) ( ) A B B A B
The holding time tholding time is given by the expression t holding time =
1 1 2 kC AO (θ B − 2)2
(θ B − 2 X A ) 2 X A (θ B − 2 ) ln (5-45) − θ B (1 − X A ) θ B (θ B − 2 X A )
Given the initial concentrations of A and B, the fractional conversion XA, and the rate constant k as the following: CAO = 0.001 gmol/1, CBO = 0.003 gmol/1, XA = 0.9, k = 105[(liter)2/(gmol2 • min)], and θB = CBO/CAO = 3, gives
1 (3 − 2 ) 2
(3 − 2 × 0.9) 2 × 0.9(3 − 2) 2 5 ln = 10 × (0.001) t holding time − 3(1 − 0.9) 3(3 − 2 × 0.9)
1[1.386 − 0.5] = 10 −1 t holding time or tholding = 8.86 min. In other words, it would take approximately 9 minutes to convert 90% of reactant A charged to the 1-liter reactor. The Microsoft Excel spreadsheet (EXAMPLE5-1.xls) was used to calculate the holding time. Example 5-2
Determine the conversion for an isothermal batch reactor using the stoichiometry of Example 5-1 and the same values of initial concentrations of A, B, C, and D in a reactor volume of 1 liter operating for 4 minutes. The rate constant is k = 105[(liter)2/(gmol2 • min)].
Introduction to Reactor Design Fundamentals for Ideal Systems
275
Solution An initial guess for the fractional conversion XA,guess on the limiting reactant A is substituted into the derived Equation 5-45. The time tguess for the fractional conversion is calculated and compared with the given holding time (tholding). If tguess < tholding, assume another guess for the fractional conversion until tguess ≅ tholding. The fractional conversion XA,guess that gives tguess ≅ tholding is the actual conversion for the batch operation at that holding time. Table 5-1 gives the results of the simulation exercise for the 4-min batch operation (using Excel spreadsheet in Example 5-1). In this exercise, the fractional conversion XA for the 4-min isothermal batch operation is 77.1%. Obviously, the required answer is obtained through trial-and-error. Equation 5-45 can be incorporated into a computer program or mathematical package such as Mathcad, Maple, Polymath, or Mathematica. Related calculation procedures can be made with different stoichiometry, which strongly influences the final form of the design expression. Also, different rate expressions often result in different relationships between time and conversion. In complex reactions, analytical integration of the design equation may be cumbersome and tedious, and perhaps impossible to solve. In such cases, the designer should resort to numerical integration methods such as the Euler Simpson’s method or graphical evaluation of ∫0X f(X)dX by plotting f(X) versus X and determining the area beneath the curve. Example 5-3
Gas A decomposes irreversibly to form gas B according to the reaction A → 2B,
(− rA ) = kC2A
(5-46)
The reaction is second order and is performed in an isothermal constant pressure batch reactor. Determine the conversion with time
Table 5-1 XA,guess tguess, min
0.75 3.598
0.76 3.782
0.77 3.979
0.771 3.999
0.772 4.02
276
Modeling of Chemical Kinetics and Reactor Design
for the reaction assuming that A and B are ideal gases, and starting with pure A at NAO. Derive a general expression for time t in terms of the fractional conversion XA for an nth order reaction expressed by A → bB. Solution Since the volume depends on conversion or time in a constant pressure batch reactor, consider the mole balance in relation to the fractional conversion XA. From the stoichiometry, Component
A
B
At time t = 0 At time t = t Amount reacted
NAO NA (NAO – NA)
0 NB NB
From the stoichiometry,
2( N AO − N A ) = N B
(5-47)
the fractional conversion XA is XA =
N AO − N A N AO
(5-8)
From Equation 5-8, the amount reacted in terms of the fractional conversion and the initial moles is
N AO − N A = N AO X A
(5-48)
and
N A = N AO (1 − X A )
(5-9)
Differentiating Equation 5-9 gives dN A = − N AO dX A
Therefore, the amount of component B is
(5-10)
Introduction to Reactor Design Fundamentals for Ideal Systems
N B = 2 N AO X A
277
(5-49)
εA is the fractional change in volume of the system between no conversion and complete conversion of reactant A given by εA =
VX A =1 − VX A = 0
(5-20)
VX A = 0
For the gas phase reaction A → 2B, εA = (2 – 1)/1 =1 or V = V O(1 + εAXA)
(5-18)
Since two moles of B are formed for every mole of A that disappears, then the mole balance table becomes
Component
Mole initially at time t = 0
Moles at t = t
NAO 0 NAO VO
NA = NAO(1 –XA) 2NAOXA NAO(1 + XA) VO(1 + XA)
A B Total moles Volume
The batch reactor design equation for component A is
(− rA ) = − V1
dN A = kC 2A dt
(5-50)
Substituting Equations 5-9, 5-10, and 5-18 into Equation 5-50 yields N (1 − X ) N dX (− rA ) = V 1 +AOX dtA = k VAO1 + X A O ( O( A) A)
2
(5-51)
Rearranging Equation 5-51 gives
(1 + X A ) dX A (1 − X A )2
=k
N AO dt VO
(5-52)
278
Modeling of Chemical Kinetics and Reactor Design
Integrating Equation 5-52 between the limits of fractional conversion t = 0, XA = 0 and t = t, XA = XA gives
(1 + X A ) dX = k N AO t dt ∫ (1 − X )2 A VO ∫ A 0 0
XA
(5-53)
Expressing the left side of Equation 5-53 into partial fraction gives Ι=
1+ XA
(1 − X A )
2
≡
A B + 1 − X A (1 − X A )2
1 + X A = A(1 − X A ) + B
(5-54) (5-55)
Putting XA = 1 into Equation 5-55 gives 2 = B. Putting XA = 0 into Equation 5-55 yields 1 =A+ B
(5-56)
and A = –1. Substituting the values of A and B into the right side of Equation 5-54 and integrating between the limits results in Ι=
XA
∫ 0
1 dX A − + (1 − X A )
[
]0
Ι = ln(1 − X A )
XA
XA
2 dX
∫ (1 − X A)2 A 0
(5-57)
X
2 A + = kC AO t 1 − X A 0
2X A ln(1 − X A ) + = kC AO t 1 − XA or t=
1 kC AO
2X A ln(1 − X A ) + 1 − XA
(5-58)
Introduction to Reactor Design Fundamentals for Ideal Systems
279
Equation 5-58 gives an expression for the reaction time and fractional conversion for an isothermal constant pressure batch reactor. Considering an nth order irreversible reaction represented by A → bB with (–rA) = kCnA, the design equation is
(− rA ) = − V1
dN A n = kC A dt
or in terms of the fractional conversion XA,
dX A 1− n n n −1 = kC AO 1 − X A ) {1 + ( b − 1)X A } ( dt
(5-59)
or 1 t = n −1 kC AO
XA
dX
∫ (1 − X )n {1 + (bA − 1)X }1− n A A 0
(5-60)
Equation 5-60 is the generalized equation, which can be used to determine the reaction time of an nth order reaction with b, the stoichiometric coefficient of the product component B.
NUMERICAL METHODS FOR REACTOR SYSTEMS DESIGN In Chapter 3, the analytical method of solving kinetic schemes in a batch system was considered. Generally, industrial realistic schemes are complex and obtaining analytical solutions can be very difficult. Because this is often the case for such systems as isothermal, constant volume batch reactors and semibatch systems, the designer must review an alternative to the analytical technique, namely a numerical method, to obtain a solution. For systems such as the batch, semibatch, and plug flow reactors, sets of simultaneous, first order ordinary differential equations are often necessary to obtain the required solutions. Transient situations often arise in the case of continuous flow stirred tank reactors, and the use of numerical techniques is the most convenient and appropriate method. Various types of numerical techniques have been developed based on the degree of accuracy and efficiency. One of the popular
280
Modeling of Chemical Kinetics and Reactor Design
methods is the Runge-Kutta fourth order method, which is described in Appendix D. It is computationally efficient and can be generally recommended for all but very stiff sets of first order ordinary differential equations. The availability and the low cost of personal computers now allow designers to focus more attention on the physical insights in the design of reactor systems. Here, the Runge-Kutta fourth order method is employed to solve a range of reaction kinetic schemes in reactor systems. In using this numerical technique, it is assumed that all concentrations are known at the initial time (i.e., t = 0). This allows the initial rate to be computed, one for each component. In choosing a small time increment, ∆t, the concentrations will change very little. These small changes in concentrations can be computed assuming the reaction rates are constant. The new concentrations are used to recalculate the reaction rates. The process is repeated until the sum of ∆t attains the specified final reaction time. Appendix D reviews other numerical methods for solving first order differential equations. SERIES REACTIONS A series of first order irreversible reactions is one in which an intermediate is formed that can then further react. A generalized series reaction is k
k
2 A 1 → B →C
( Desired ) ( Unwanted )
(5-61)
in a constant volume batch system and constant temperature T. For the batch reactor, the following rate equations can be written. For component A disappearing in the system,
(− rA ) = −
dC A = k1C A dt
(5-62)
The rate equation of component B disappearing is:
(− rB )net = −
dC B = k 2 C B − k1C A dt
The rate equation of component C formed is
(5-63)
Introduction to Reactor Design Fundamentals for Ideal Systems
(+ rC ) =
dC C = k 2CB dt
281
(5-64)
Rearranging Equations 5-62 and 5-63 gives dC A = − k1C A dt
(5-65)
dC B = k1C A − k 2 C B dt
(5-66)
Equations 5-64, 5-65, and 5-66 are first order differential equations, which require initial or boundary conditions. For the batch reactor, these are the initial concentrations of A, B, and C. In addition to the initial concentrations, the rate constants k1 and k2 are also required to simulate their concentrations. The concentration profiles depend on the values of k1 and k2 (i.e, k1 = k2, k1 > k2, k2 > k1). Assume that at the beginning of the batch process, at time t = 0, CAO = 1.0 mol/m3, and CBO = CCO = 0. For known values of k1 and k2, simulate the concentrations of A, B, and C for 10 minutes at a time interval of t = 0.5 min. A computer program has been developed using the Runge-Kutta fourth order method to determine the concentrations of A, B, and C. The differential Equations 5-64, 5-65, and 5-66 are expressed, respectively, in the form of X-arrays and functions in the computer program as CA = X(1),
dC A = F(1) dt
(5-67)
CB = X(2),
dC B = F(2 ) dt
(5-68)
CC = X(3),
dC C = F(3) dt
(5-69)
where
F(1) = − K1 * X(1)
(5-70)
F(2) = K1* X(1) − K 2 * X(2)
(5-71)
282
Modeling of Chemical Kinetics and Reactor Design
F(3) = K 2 * X(2)
(5-72)
The computer program BATCH51 determines the concentration profiles with time increment h = ∆t = 0.5 min for a period of 10 minutes for k1 = k2 = 1.0 min–1; k1 = 1.0 min–1, k2 = 0.1 min–1; and k1 = 0.1 min–1, k2 = 1.0 min–1, respectively. Tables 5-2, 5-3, and 5-4, respectively, give the results of the computer program and Figures 5-5, 5-6, and 5-7 illustrate the profiles for varying values of the reaction rate constants. The optimum concentration of the desired product B is determined from the plots. For k2 k k1 in Figure 5-7, the concentration of the intermediate k k2 B remains small. The reaction scheme A 1 → B → C , therefore, k2 resembles the single reaction A → C , as B is negligibly small. As k2/k1 > 50, the numerical technique becomes unstable and the corresponding equations are known as “stiff differential equations.” In this case, other numerical techniques may be used such as the one-point implicit method, the two-point trapezoidal rule, or multi-point methods. An industrial example of series reactions is the substitution process involving methane and chlorine:
Table 5-2 Simulation of a chemical reaction kinetics A → B → C in a batch reactor (k1 = 1.0, k2 = 1.0)
Introduction to Reactor Design Fundamentals for Ideal Systems
Table 5-3 Simulation of a chemical reaction kinetics A → B → C in a batch reactor (k1 = 1.0, k2 = 0.1)
Table 5-4 Simulation of a chemical reaction kinetics A → B → C in a batch reactor (k1 = 0.1, k2 = 1.0)
283
284
Modeling of Chemical Kinetics and Reactor Design
Figure 5-5. Concentrations versus time of A, B, and C in a series reaction k1 2 A → B k → C for k2/k1 = 1.
Figure 5-6. Concentrations versus time of A, B, and C in a series reaction k1 2 A → B k → C for k2/k1 = 0.10.
Introduction to Reactor Design Fundamentals for Ideal Systems
285
Figure 5-7. Concentrations versus time of A, B, and C in a series reaction k1 2 A → B k → C for k2/k1 = 10.
CH 4 + Cl 2 → CH 3Cl + HCl CH 3Cl + Cl 2 → CH 2 Cl + HCl
CH 2 Cl 2 + Cl 2 → CHCl 3 + HCl CH 3Cl + Cl 2 → CCl 4 + HCl
Series reactions also occur in oxidation processes where the required product may oxidize further. An example is the production of maleic anhydride from the oxidation of benzene. In this case, the maleic anhydride can be oxidized further to carbon dioxide and water. Another example of a series reaction occurs in the biochemical reaction in which Pseudomonas ovalis is used to convert glucose to gluconic acid via gluconolactone in batch culture. This first order reaction is represented by k
k
2 G 1 → L →P
glucose gluconolactone gluconic acid
286
Modeling of Chemical Kinetics and Reactor Design
The time tmax at which the concentration of the intermediate (gluconolactone) is maximized and the maximum concentration gluconolactone (CL)max have already been reviewed in Chapter 3. The simulation of this reaction is reviewed in Chapter 11. SIMULTANEOUS IRREVERSIBLE SIDE REACTIONS Consider the reaction schemes k
▲
A 1 → B
(5-73)
k2
C in a constant volume batch isothermal reactor with known values of the rate constants k1 and k2, and initial concentrations of CAO = 1.0 mol/m3 and CBO = CCO = 0.0 mol/m3. The reactions are first order. The concentrations of A, B, and C can be simulated with time using the following rate equations:
(− rA ) = −
dC A = ( k1 + k 2 ) C A dt
(5-74)
(+ rB ) =
dC B = k1C A dt
(5-75)
(+ rC ) =
dC C = k 2C A dt
(5-76)
Rearranging Equation 5-74 gives
dC A = − ( k1 + k 2 )C A dt
(5-77)
Equations 5-75, 5-76, and 5-77 are first order differential equations. The concentrations of A, B, and C can be simulated for k1 = 0.25 hr–1
Introduction to Reactor Design Fundamentals for Ideal Systems
287
and k2 = 0.75 hr–1 for a period of 5 hours with time increment h = ∆t = 0.5 hr–1. Using the developed Runge-Kutta fourth order computer program BATCH52, the concentrations of A, B, and C can be predicted for any specified time duration. Figure 5-8 shows the plots of these concentrations. The figure shows the exponential decrease with time of component A, while B and C increase asymptotically to their ultimate concentrations.
REVERSIBLE SERIES REACTIONS Consider chemical reaction schemes of the form k1
3 A [ B →C
k2
k
(5-78)
in which A reacts to form B and C in a constant volume batch reactor under isothermal condition. The rate equations for components A, B, and C are
Figure 5-8. Concentrations versus time of A, B, and C in a simultaneous irreversible reaction for k1 = 0.25 hr–1 and k2 = 0.75 hr–1.
288
Modeling of Chemical Kinetics and Reactor Design
(− rA )net = −
dC A = k1C A − k 2 C B dt
(5-79)
(− rB )net = −
dC B = k 2 C B + k 3C B − k1C A dt
(5-80)
(+ rC ) =
dC C = k 3C B dt
(5-81)
Rearranging Equations 5-79 and 5-80 gives
dC A = k 2 C B − k1C A dt
(5-82)
dC B = k1C A − ( k 2 + k 3 )C B dt
(5-83)
Equations 5-81, 5-82 and 5-83 are first order differential equations that can be solved simultaneously using the Runge-Kutta fourth order method. Consider two cases: At time t = 0, CAO = 1.0, CBO = CCO = 0, and k1 = k2 = 1, k3 = 10 • Case II: At time t = 0, CAO = 1.0, CBO = CCO = 0, and k1 = 1, k2 = k3 = 10
• Case I:
The developed batch program BATCH53 simulates the concentrations of A, B, and C with time step ∆t = 0.05 hr for 1 hour. Figures 5-9 and 5-10 show plots of the concentrations versus time for both cases. CONSECUTIVE REVERSIBLE REACTIONS Consider the chemical reversible reactions k
k
k2
k4
A ←1 → B ←3 → C
(5-84)
in a constant volume batch reactor under isothermal condition. For first order reaction kinetics, the rate equations are:
Introduction to Reactor Design Fundamentals for Ideal Systems
289
Figure 5-9. Concentrations versus time of A, B, and C in a simultaneous irreversible reaction for k1 = k2 = 1.0 hr–1 and k3 = 10 hr–1.
Figure 5-10. Concentrations versus time of A, B, and C in a simultaneous irreversible reaction for k1 = 1.0 hr–1 and k2 = k3 = 10 hr–1.
290
Modeling of Chemical Kinetics and Reactor Design
(− rA ) = −
dC A = k1C A − k 2 C B dt
(− rB )net = −
(− rC ) = −
(5-85)
dC B = ( k 2 + k 3 ) C B − k1 C A − k 4 C C dt
(5-86)
dC C = k 4 C C − k 3C B dt
(5-87)
Rearranging Equations 5-85, 5-86, and 5-87 gives
dC A = k 2 C B − k1C A dt
(5-88)
dC B = k1C A + k 4 C C − ( k 2 + k 3 ) C B dt
(5-89)
dC C = k 3C B − k 4 C C dt
(5-90)
Equations 5-88, 5-89, and 5-90 are first order differential equations and the Runge-Kutta fourth order method with the boundary conditions is used to determine the concentrations versus time of the components. At the start of the batch, t = 0, CAO = 1, CBO = CCO = 0, k1 = 1.0 hr–1, k2 = 2.0 hr–1, k3 = 3.0 hr–1, and k4 = 4.0 hr–1. Computer program BATCH54 simulates the concentrations of A, B, and C for the duration of 2 hours with a time increment h = ∆t = 0.2 hr. Figure 5-11 shows the concentrations versus time of A, B, and C. Note that when increasing the time increment beyond h = ∆t = 0.3 hr, the values of the concentrations become very unstable and the corresponding differential equations are said to be “stiff.” An industrial example of a consecutive reversible reaction is the catalytic isomerization reactions of n-hexane to 2-methyl pentane and 3-methyl pentane and is represented as: k
k
k2
k4
n C 6 H14 ←1 → 2 − methyl pentane ←3 → 3 − methyl pentane A
B
C
where 2-methyl pentane is the most desirable product.
Introduction to Reactor Design Fundamentals for Ideal Systems
291
Figure 5-11. Concentrations versus time of A, B, and C in a simultaneous irreversible reaction for k1 = 1.0 hr–1, k2 = 2.0 hr –1, k3 = 3 hr–1, and k 4 = 4 hr–1.
PARALLEL SECOND ORDER REACTIONS Consider an irreversible chemical reactions scheme of the form k
A + B 1 → C k
2 A + C →D
(5-91)
in which A reacts with B to form C and with further reaction of A with C to form D in a constant volume batch reactor under isothermal conditions. The rate equations for components A, B, C, and D are
(− rA )net = − (− rB ) = −
dC A = k1C A C B + k 2 C A C C dt
dC B = k1C A C B dt
(5-92)
(5-93)
292
Modeling of Chemical Kinetics and Reactor Design
(− rC )net = − (+ rD ) =
dC C = k 2 C A C C − k1C A C B dt
dC D = k 2C ACC dt
(5-94) (5-95)
Rearranging Equations 5-92, 5-93, and 5-94 gives
dC A = − ( k1C A C B + k 2 C A C C ) dt
(5-96)
dC B = − k1C A C B dt
(5-97)
dC C = k1C A C B − k 2 C A C C dt
(5-98)
Equations 5-95, 5-96, 5-97, and 5-98 are first order differential equations and the Runge-Kutta fourth order method is used to simulate the concentrations, with time, of components A, B, C, and D at varying ratios of k2/k1 of 0.5, 1.0, and 2.0 for a time increment ∆t = 0.5 min. At the start of the batch process, the initial concentrations at time t = 0, are C AO = CBO = 1.0 mol/m 3 , C CO = C DO = 0.0 mol/m 3 . The computer program BATCH55 simulates the concentrations of A, B, C, and D for a period of 5 minutes. Figures 5-12, 5-13, and 5-14, respectively, show the profiles of the concentrations with time, and the effect of k2/k1 on the concentrations of species of A, B, C, and D. The maximum conversion of component C depends on the ratio of k2/k1. COMPLEX REACTIONS IN A BATCH SYSTEM Industrial chemical reactions are often more complex than the earlier types of reaction kinetics. Complex reactions can be a combination of consecutive and parallel reactions, sometimes with individual steps being reversible. An example is the chlorination of a mixture of benzene and toluene. An example of consecutive reactions is the chlorination of methane to methyl chloride and subsequent chlorination to yield carbon tetrachloride. A further example involves the chlorination of benzene to monochlorobenzene, and subsequent chlorination
Introduction to Reactor Design Fundamentals for Ideal Systems
293
Figure 5-12. Concentrations versus time of A, B, C, and D in parallel second order reactions for k1 = 1.0 m3/mol • min and k2 = 0.5 m3/mol • min.
Figure 5-13. Concentrations versus time of A, B, C, and D in parallel second order reactions for k1 = 1.0 m3/mol • min and k2 = 1.0 m3/mol • min.
294
Modeling of Chemical Kinetics and Reactor Design
Figure 5-14. Concentrations versus time of A, B, C, and D in parallel second order reactions for k1 = 1.0 m3/mol • min and k2 = 2.0 m3/mol • min.
of the mono- to yield dichlorobenzene and trichlorobenzene, respectively. These reaction mechanisms are expressed as: k
C 6 H 6 + Cl 2 1 → C 6 H 5Cl + HCl k
2 C 6 H 5Cl + Cl 2 → C 6 H 4 Cl 2 + HCl
k
3 C 6 H 4 Cl 2 + Cl 2 → C 6 H 3Cl 3 + HCl
Analysis in terms of series and parallel steps is: C 6 H 6 → C 6 H 5Cl → C 6 H 4 Cl 2 → C 6 H 3Cl 3 C 6 H 5Cl Cl 2
C 6 H 4 Cl 2 C 6 H 3Cl 3
Introduction to Reactor Design Fundamentals for Ideal Systems
295
When a substance participates in several reactions at the same time as exemplified in the above reaction, its net formation rate or disappearance is the algebraic sum of its rates in the elementary reactions. The following examples review some complex reactions and determine the concentrations history for a specified period using the RungeKutta fourth order numerical method.
Example 5-4 Consider the reaction scheme k
A 1 → B k2
B[ C k3
k
4 B →D
(5-99)
in a constant volume batch reactor rate constants are k1 = 5 hr–1, k2 = initial concentrations are CAO = 16 mol/l. The concentrations of A, B, of 2 hours will be determined.
under isothermal conditions. The 4 hr–1, and k3 = k4 = 3 hr–1. The mol/l and CBO = CCO = CDO = 0 C, and D with time for a period
Solution Assuming that the reactions are first order in a constant volume batch reactor, the rate equations for components A, B, C, and D, respectively, are:
(− rA ) = −
dC A = k1C A dt
(− rB )net = −
(− rC ) = −
dC B = ( k 2 + k 4 ) C B − k1C A − k 3C C dt
dC C = k 3C C − k 2 C B dt
(5-100)
(5-101)
(5-102)
296
Modeling of Chemical Kinetics and Reactor Design
(+ rD ) =
dC D = k 4CB dt
(5-103)
Rearranging Equations 5-100, 5-101, and 5-102 gives
dC A = − k1C A dt
(5-104)
dC B = k1C A + k 3C C − ( k 2 + k 4 ) C B dt
(5-105)
dC C = k 2 C B − k 3C C dt
(5-106)
Equations 5-103, 5-104, 5-105, and 5-106 are first order differential equations. The computer program BATCH56 simulates the above differential equations with time increment = ∆t = 0.2 hr. Table 5-5 gives the results of the simulation and Figure 5-15 shows plots of the concentrations versus time.
Example 5-5 Consider the simulation of a constant volume batch reaction of the form k
A + D 1 → B k
2 B + D → C
k
3 D + D →E
(5-107)
The reactor initially contains 0.l2 mol/m3 of A and 0.4 mol/m3 of D with the rate constants k1 = 0.4, k2 = 0.2, and k3 = 0.05 m3/mol • min. What are the compositions of A, B, C, and D after 5 minutes? Solution Assume the rates to be second order in a constant volume batch system and determine the rate equations as follows.
Introduction to Reactor Design Fundamentals for Ideal Systems
297
Table 5-5 Simulation of complex chemical reactions A → B, B ↔ C, B → D in a batch reactor (k1 = 5.0, k2 = 4.0, k3 = 3.0, k4 = 3.0)
Figure 5-15. Concentrations versus time of A, B, C, and D in complex reactions for k1 = 5.0 hr–1, k2 = 4 hr–1, and k3 = k4 = 3 hr–1.
298
Modeling of Chemical Kinetics and Reactor Design
For component A, the reaction rate is expressed by
(− rA ) = −
dC A = k1C A C D dt
(5-108)
The reaction rate of component B is
(− rB )net = −
dC B = k 2 C BC D − k1C A C D dt
(5-109)
The rate of appearance of component C is
(+ rC ) =
dC C = k 2 C BC D dt
(5-110)
The reaction rate of component D is
(− rD )net
=−
dC D = k1C A C D + k 2 C BC D + k 3C 2D dt
(5-111)
Rearranging Equations 5-108, 5-109, and 5-111, respectively, gives
dC A = − k1C A C D dt
(5-112)
dC B = k1C A C D − k 2 C BC D dt
(5-113)
dC D = − ( k1C A C D + k 2 C BC D + k 3 C 2D ) dt
(5-114)
Equations 5-110, 5-112, 5-113, and 5-114 are first order differential equations and the Runge-Kutta fourth order numerical method is used to determine the concentrations of A, B, C, and D, with time, with a time increment h = ∆t = 0.5 min for a period of 10 minutes. The computer program BATCH57 determines the concentration profiles at an interval of 0.5 min for 10 minutes. Table 5-6 gives the results of the computer program and Figure 5-16 shows the concentration profiles of A, B, C, and D from the start of the batch reaction to the final time of 10 minutes.
Introduction to Reactor Design Fundamentals for Ideal Systems
299
Table 5-6 Simulation of complex chemical reactions A + D → B, B + D → C, D + D → E in a batch reactor (k1 = 0.4, k2 = 0.2, k3 = 0.05)
Figure 5-16. Concentrations versus time of A, B, C, and D in complex reactions for k1 = 0.40 m3/mol • min, k2 = 0.2 m3/mol • min, and k3 = 0.05 m3/mol • min.
300
Modeling of Chemical Kinetics and Reactor Design
Example 5-6
Consider the reaction scheme k
k
A ←1 → B 3 → C k2
k5
k4
(5-115)
D in a constant volume batch reactor under isothermal conditions, and with the rate constants k1 = 0.4 hr–1, k2 = 0.1 hr–1, k3 = 0.16 hr–1, k4 = 0.08 hr–1, and k5 = 0.13 hr–1. The original compositions in the batch are: CA = 7 gmol/l CB = 2.0 gmol/l CC = 0 gmol/l CD = 0.5 gmol/l Determine the concentrations of each component as a function of time for 2 hours.1 Solution From the reaction scheme, it can be assumed the rate equations are first order. The rate of disappearance of component A is:
(− rA ) net
=−
dC A = k1C A − k 2 C B dt
(5-116)
The rate of disappearance of component B is:
1 D. M. Himmelblau and K. B. Bischoff, Process Analysis & Simulation-Deterministic Systems, John Wiley, 1968.
Introduction to Reactor Design Fundamentals for Ideal Systems
(− rB )net = −
dC B = ( k 2 + k 3 + k 4 )C B − k1C A − k 5C D dt
301
(5-117)
The rate of formation of component C is:
(rC ) =
dC C = k 3C B dt
(5-118)
The rate of disappearance of component D is:
(− rD )net = −
dC D = k 5C D − k 4 C B dt
(5-119)
Rearranging Equations 5-116, 5-117, and 5-119, respectively, gives
dC A = k 2 C B − k1C A dt
(5-120)
dC B = k1C A + k 5C D − ( k 2 + k 3 + k 4 )C B dt
(5-121)
dC D = k 4 C B − k 5C D dt
(5-122)
Equations 5-118, 5-120, 5-121, and 5-122 are first order differential equations. A simulation exercise on the above equations using the Runge-Kutta fourth order method, can determine the number of moles with time increment h = ∆t = 0.2 hr for 2 hours. Computer program BATCH58 evaluates the number of moles of each component as a function of time. Table 5–7 gives the results of the simulation, and Figure 5-17 shows the plots of the concentrations versus time. Example 5-7
A pair of reactions k
A + B 1 → 2C k
2 A + C →D
(5-123)
302
Modeling of Chemical Kinetics and Reactor Design
Table 5-7 Simulation of complex chemical reactions in a batch reactor (k1 = 0.4, k2 = 0.1, k3 = 0.16, k4 = 0.08, k5 = 0.13)
Figure 5-17. Concentrations versus time of A, B, C, and D in complex reactions for k1 = 0.4 hr–1, k2 = 0.1 hr–1, k3 = 0.16 hr–1, k4 = 0.08 hr–1, and k5 = 0.13 hr–1.
Introduction to Reactor Design Fundamentals for Ideal Systems
303
is carried out in a constant volume batch reactor with k1 = 0.1 ft3/ (lb-mol)(min) and k2 = 0.05 ft3/(lb-mol)(min). The concentrations of A and B are such that at time t = 0, CAO = 3CBO = 0.9 lb-mol/ft3. The concentrations of C and D at initial time t = 0 are CCO = CDO = 0.0 lb-mol/ft3. Determine the concentrations of A, B, C, and D as a function of time for the duration of 12 minutes.2 Solution
Assuming that the rate equations are second order, the rate of disappearance of component A is:
(− rA ) = −
dC A = k1C A C B + k 2 C A C C dt
(5-124)
The rate of disappearance of component B is
(− rB ) = −
dC B = k1C A C B dt
(5-125)
Rearranging Equation 5-124 and 5-125 gives dC A = − ( k1C A C B + k 2 C A C C ) dt 2
S. M. Walas, Reaction Kinetics for Chemical Engineers, McGraw-Hill, NY, 1959.
(5-126)
304
Modeling of Chemical Kinetics and Reactor Design
dC B = − k1C A C B dt
(5-127)
The material balance from the stoichiometry is Component
A
B
C
D
At time t = 0 At time t = t Amount reacted
CAO CA CAO – CA
CBO CB CBO – CB
0 CC CC
0 CD CD
The reaction steps are parallel with respect to component A and series with respect to component B. That is, A + B → 2C; 2A + 2C → 2D; 3A + B → 2D:
Parallel steps:
A 2A Series steps: B + → 2C + → 2 D
For an isothermal, well-mixed constant volume batch reactor, at time t = 0: nAO mols of A, nBO mols of B, and nAO = 3nBO. At any time, t: nA mols of A, nB mols of B, nC mols of C, and nD mols of D. nD mols requires nD/2 mols of B and 3nD/2 mols of A. nC mols requires nC/2 mols of B and nC/2 mols of A. Consequently:
nD nC + = n BO − n B (Amount of B reacted) 2 2 3n D n C + = n AO − n A (Amount of A reacted) 2 2
Introduction to Reactor Design Fundamentals for Ideal Systems
305
Therefore,
3n D 3n C + = 3n BO − 3n B 2 2 and 3n D n C + = n AO − n A 2 2
Mols of C:
nC = 3(nBO – nB) – (nAO – nA) or
Concentration of C: Mols of D:
C C = 3(C BO − C B ) − (C AO − C A )
(5-128)
nD = (nAO – nA) – (nBO – nB) or
Concentration of D:
C D = (C AO − C A ) − (C BO − C B )
(5-129)
but CAO = 3CBO. Therefore, the material balance on component C is C C = C A − 3C B
(5-130)
and concentration of component D becomes
C D = (0.9 − C A ) − (0.3 − C B )
(5-131)
C D = 0.6 − C A + C B
(5-132)
This means CD = 0.6 when CA = CB = 0. Substituting Equation 5-130 into Equation 5-126 gives
dC A = − k 2 C A (C A − 3C B ) − k1C A C B dt
(5-133)
The differential Equations 5-127 and 5-133 are solved using the Runge-Kutta fourth order while components C and D are calculated from the mass balance of Equations 5-130 and 5-132, respectively, at a time increment of h = ∆t = 0.5 min. The computer program BATCH59 calculates the concentrations of A, B, C, and D as function
306
Modeling of Chemical Kinetics and Reactor Design
of time for 12 minutes. Table 5-8 gives the results of the simulation and Figure 5-18 shows the concentration profiles of the components.
THE SEMIBATCH REACTOR Some chemical reactions are unsuitable to either batch or continuous operation in a stirred vessel because the heat liberated (generated) during the reaction may be highly exothermic and likely to cause dangerous conditions. Under these circumstances, reactions are sometimes carried out under semibatch conditions. This means that one or more reagents, which do not react, are entered completely into a batch container; the final reagent is then added under controlled conditions. Product is not withdrawn until the entire reagent has been added and the reaction has proceeded to the required extent. A semibatch reactor operates under an unsteady state condition. When the reaction heat is high there is better control of the energy, which evolves by regulating
Table 5-8 The concentration-time curve of a complex chemical reaction k2 1 of A + B k → 2C, A + C → D (k1 = 0.1, k2 = 0.05)
Introduction to Reactor Design Fundamentals for Ideal Systems
307
Figure 5-18. Concentrations versus time of A, B, C, and D with second order chemical reactions for k1 = 0.4 ft3/lb-mol • min and k2 = 0.05 ft3/lb-mol • min.
the addition rate of one of the reactants. The semibatch reactor also allows some degree of control over concentration of the reaction mixture, and therefore the rate of reaction. k1 Consider the reaction A + B → C that is performed in a semibatch reactor as shown in Figure 5-19, where the reaction is first order and carried out by the controlled addition of reactant B. Assuming that the reaction is first order with respect to both A and B (i.e., second order overall), the rate of disappearance of components A and B is (–rA) = (–rB) = k1CACB. Following considers the material balances of both components A and B. From the material balance Equation 5-1 Input Output Disappearance Rate of = + + Rate Rate by reaction Accumulation (− rA )V (− rB )V
(5-1)
308
Modeling of Chemical Kinetics and Reactor Design
Figure 5-19. The semibatch reactor.
At constant density
dVR =F dt
(5-134)
with an initial condition, Equation 5-134 can be integrated to give
∫ dVR = F ∫ dt + Const.
(5-135)
VR = Ft + Const.
(5-136)
at t = 0, VR = VO and Const. = VO. Therefore, the volume of the semibatch mixture is VR = Ft + VO
(5-137)
Considering the material balance on reagent B, from
Input Output Disappearance Rate of = + + Rate Rate by reaction Accumulation F C BO = 0 + k1C A C BVR + Therefore,
d (VR C B ) dt
(5-1)
(5-138)
Introduction to Reactor Design Fundamentals for Ideal Systems
d (VR C B ) = F C BO − k1 C A C B VR dt
309
(5-139)
The material balance on reactant A, from
Input Output Disappearance Rate of = + + Rate Rate by reaction Accumulation 0 = 0 + k1C A C BVR +
d (VR C A ) dt
(5-1)
(5-140)
Therefore, d (VR C A ) = − k1C A C BVR dt
(5-141)
The material balance on product C is
d (VR CC ) = k1C A C BVR dt
(5-142)
Using the differentiation of a product on A gives VR
dC A dV + C A R + k1C A C BVR = 0 dt dt
(5-143)
VR
dC A dV = − k1C A C BVR − C A R dt dt
(5-144)
or
but
dVR =F dt
(5-134)
Therefore,
dC A C dVR = − k1C A C B − A dt VR dt
(5-145)
310
Modeling of Chemical Kinetics and Reactor Design
Substituting Equation 5-134 into Equation 5-145 yields
dC A C F = − k1C A C B − A dt VR
(5-146)
Material balance on B gives VR
dC B dV + C B R = FC BO − k1C A C BVR dt dt
(5-147)
Rearranging Equation 5-147 yields dC B F C BO C dVR = − k1C A C B − B dt VR VR dt
(5-148)
that is, dC B F C BO C F = − k1C A C B − B dt VR VR
(5-149)
Material balance on C gives
VR
dC C dV + C C R = k1C A C BVR dt dt
(5-150)
Rearranging Equation 5-150 gives dC C C dVR = k1C A C B − C dt VR dt
(5-151)
Therefore,
dC C C F = k1C A C B − C dt VR
(5-152)
The volume of the batch with respect to time t is VR = Ft + VO
(5-137)
Introduction to Reactor Design Fundamentals for Ideal Systems
311
Equations 5-146, 5-149, and 5-152 are first order differential equations. The concentration profiles of A, B, C, and the volume V of the batch using Equation 5-137 is simulated with respect to time using the Runge-Kutta fourth order numerical method. Equations 5-137, 5-146, 5-149, and 5-152 can be incorporated respectively in the subprogram of a computer code as follows
VR = U * T + V
(5-153)
F(1) = − ( K1* X(1) * X(2)) − ( X(1) * U V R )
(5-154)
F(2) = ( U*) − ( K1 * X(1) * X(2) ) − ( X(2) * U V R )
(5-155)
F(3) = ( K1 * X(1) * X(2)) − ( X(3) * U V R )
(5-156)
where
F(1) =
dC dC A dC , F(2) = B , F(3) = C dt dt dt
and X(1) = C A , X(2) = C B , X 20 = C BO , X(3) = C C
Semibatch reactor conditions are illustrated in Table 5-9. The computer program BATCH510 was developed incorporating Equations 5-156, 5-157, 5-158, and 5-159 in the subprogram of the Runge-Kutta fourth order program. The results of the simulation are
Table 5-9 Velocity constant Initial concentrations
Charge rate Charge concentration Initial volume
k1 = 10 l/hr • mol CAO = 1.0 mol/l CB = 0.0 mol/l CCO = 0.0 mol/l U = 100 l/hr CBO = 1.0 mol/l V = 100 l
312
Modeling of Chemical Kinetics and Reactor Design
shown in Table 5-10. Figure 5-20 shows the concentration profiles of A, B, C, and volume V during a period of 1 hour. Semibatch reactors can be employed when parallel reactions of different orders occur. In such cases, it may be economical to use a semibatch rather than a batch operation.
CONTINUOUS FLOW STIRRED TANK REACTOR (CFSTR) The contents of a continuously operated stirred tank are assumed to be perfectly mixed, so that the properties (e.g., concentration, temperature) of the reaction mixture are uniform in all parts of the system. Therefore, the conditions throughout the tank are the same and equal to the conditions at the outlet. This means that the volume element can be taken as the volume, V R, of the entire contents. Additionally, the composition and temperature at which the reaction occurs are the same as the composition and temperature of any exit stream. A continuous flow stirred tank reactor as shown in Figure 5-21 assumes that the fluid is perfectly well mixed. Additionally, the following is also assumed: • Isothermal operation (i.e., constant temperature) • Steady state condition • No change in liquid density
Table 5-10 Simulation of the semibatch reator concentrations involving the chemical reaction A + B → C (k1 = 10.0)
Introduction to Reactor Design Fundamentals for Ideal Systems
313
Figure 5-20. Semibatch reactor concentrations, volume versus time.
The following notations are used:
volume u = volumetric flowrate unit time
(− rA )net = moles
of A disappearing by reaction (unit volume)(time)
314
Modeling of Chemical Kinetics and Reactor Design
Figure 5-21. The continuous flow stirred tank reactor (CFSTR).
M A = molecular weight
moles C A = concentration volume δV = VR = volume of the reactor
Accumulation = 0 (no change with time) Input during δt = Output during δt By flow u • δt • CAO • MA = u • δt • CA • MA By reaction
+ (–rA) • VR • δt • MA
uC AO = u C A + ( − rA )VR
(5-157) (5-158)
In terms of the fractional conversion XA, XA =
C AO − C A C AO
(5-14)
Introduction to Reactor Design Fundamentals for Ideal Systems
C A = C AO (1 − X A )
315
(5-28)
Substituting Equation 5-28 into Equation 5-158 gives uC AO = uC AO (1 − X A ) + ( − rA )VR
(5-159)
Equation 5-159 can be rearranged in terms of the residence time t of fluid in the reactor as t=
C X VR = AO A u (− rA )
(5-160)
XA and (–rA) are determined at the exit stream conditions, which are the same conditions as in the reactor of volume VR. For constant density system, the performance equation in terms of CA becomes t=
C − CA VR = AO u (− rA )
(5-161)
These expressions relate the terms XA, (–rA), VR, and u. Therefore, the fourth term can be determined if the remaining terms are known. When designing, the size of the reactor needed for a given duty or the extent of conversion in a reactor of given size can be directly obtained. IRREVERSIBLE REACTIONS Consider the nth-order irreversible reaction of the form A → products, (–rA) = kCAn , in a constant density single-stage CFSTR. If n = 1, Equation 5-158 becomes uC AO = uC A + kC A VR
(5-162)
where t = V R/u, the mean residence time. Rearranging Equation 5-162 yields CA =
C AO 1 + kt
(5-163)
316
Modeling of Chemical Kinetics and Reactor Design
k → B , the concentration of comIf the reaction is of the form A ponent B can be determined from the stoichiometry:
C AO − C A = C B − C BO
(5-164)
If CBO = 0, Equation 5-164 becomes C B = C AO − C A
(5-165)
where
CA =
C AO 1 + kt
(5-163)
The concentration of B then becomes C B = C AO − =
C AO 1 + kt
C AO kt 1 + kt
(5-166)
The mean residence time is evaluated in terms of the fractional conversion as defined by CA = CAO(1 – XA). The material balance for the single CFSTR in terms of XA for the first order irreversible reaction is
uC AO = uC A + kC A VR uC AO = uC AO (1 − X A ) + kC AO (1 − X A ) VR uC AO X A = kC AO VR (1 − X A )
(5-167)
The fractional conversion XA is determined from Equation 5-167 in terms of the mean residence time t = (VR/u) to yield
XA =
kt 1 + kt
(5-168)
Introduction to Reactor Design Fundamentals for Ideal Systems
317
REVERSIBLE REACTION Consider the first order reversible reaction of the form k1
A [ B, ( − rA ) = k1C A − k 2 C B k2
in a single-stage CFSTR at constant density. The material balance is uC AO = uC A + ( − rA ) Vr (5-169)
= uC A + ( k1C A − k 2 C B ) VR From the stoichiometry: Component
A
B
At time t = 0 At time t = t Amount reacted
CAO C (CAO – C A)
0 CB CB
Therefore, C AO − C A = C B
(5-170)
Substituting Equation 5-170 into Equation 5-169 gives
[
uC AO = uC A + k1C A − k 2 (C AO − C A
)] VR
(5-171)
Rearranging Equation 5-171 for CA in terms of the mean residence time t and CAO yields CA =
C AO (1 + k 2 t )
[1 + (k1 + k 2 ) t ]
(5-172)
As t → ∞, the compositions of A and B will be in equilibrium, that is K=
X A equ k1 C Bequ = = k 2 C A equ 1 − X A equ
318
Modeling of Chemical Kinetics and Reactor Design
However, if k2 = 0, Equation 5-172 becomes an expression for the irreversible first order. The mean residence time is determined in terms of the fractional conversion XA from Equation 5-171 as follows
(C AO − C A ) = X A C AO
(5-14)
and C A = C AO (1 − X A )
(5-28)
Substituting Equation 5-14 and 5-28 into Equation 5-171 gives
[
]
uC AO = uC AO (1 − X A ) + k1C AO (1 − X A ) − k 2 C AO X A VR
[
]
uC AO X A = C AO k1 (1 − X A ) − k 2 X A VR
(5-173) (5-174)
The mean residence time t in terms of the fractional conversion XA from Equation 5-174 is t=
XA k1 (1 − X A ) − k 2 X A
(5-175)
Similarly, the mean residence time t in terms of CA is t=
C AO − C A k1C A − k 2 (C AO − C A )
(5-176)
SERIES REACTION Consider the series first order irreversible reaction of the form k k2 A 1 → B → C in a constant density CFSTR. The material balance of component A is uCAO = uCA + k1CAVR. The material balance of component B is uCBO = uCB + (k2CB – k1CA)VR. The material balance of component C is uCCO = uCC – k2CBVR. Assuming that CBO = CCO = 0, then the exit concentration of components A, B, and C are CA =
C AO 1 + kt
Introduction to Reactor Design Fundamentals for Ideal Systems
CB =
k1C AO t (1 + k1t )(1 + k 2 t )
CC =
k1k 2 C AO t 2 (1 + k1t )(1 + k 2 t )
319
(5-177)
The maximum concentration of B is determined by dC B / dt max = 0:
{
}
dC B −1 −1 = k1C AO t max (1 + k1t max ) (1 + k 2 t max ) = 0 dt max
(5-178)
Using the differentiation of a product as d du dv dw ( uvw) = VW + UW + UV dt dt dt dt
on Equation 5-178 gives k1C AO (1 − k1k 2 t 2max ) dC B =0= dt max (1 + k1t max )2 (1 + k 2 t max )2
(5-179)
k1C AO (1 − k1k 2 t 2max ) = 0 k1C AO = 0
or 1 − k1k 2 t 2max = 0 t max =
1 k1k 2
(5-180)
Substituting the maximum time t max from Equation 5-180 into Equation 5-177 for the maximum concentration of B followed by further mathematical manipulation gives
320
Modeling of Chemical Kinetics and Reactor Design
C B max =
(
k1C AO 12 k1 + k12 2
)
(5-181)
Equation 5-181 is useful in obtaining the maximum yield of component B in a CFSTR. SECOND ORDER IRREVERSIBLE REACTION Consider the liquid phase second order irreversible reaction of the form A + B → products in a CFSTR at constant density under stable conditions. Assume that the reaction is irreversible and first order with respect to each species A and B and second order overall. The reaction rate for component A is represented by (–rA) = kCACB. Also assume that the tank is well mixed, and the concentrations of A and B are uniform at any time in the tank. Additionally, assume that the total holdup in the reactor is steady, and that flowrate through it is constant at u m3/min. Applying the material balance of Equation 5-1 on species A gives
dC A dt
uC AO = uC A + kC A C BVR + VR
At steady state condition, VR
(5-182)
dC A =0 dt
The material balance on component B is
uC BO = uC B + kC A C BVR + VR
dC B dt
At steady state condition, VR
(5-183)
dC B =0 dt
Equations 5-182 and 5-183 become
uC AO = uC A + kC A C BVR
(5-184)
uC BO = uC B + kC A C BVR
(5-185)
Introduction to Reactor Design Fundamentals for Ideal Systems
321
where u is the volumetric flowrate entering the reactor. Rearranging Equation 5-184 gives
u(C AO − C A ) = kC A C BVR
(5-186)
From stoichiometry,
C AO − C A = C BO − C B or C B = C BO − (C AO − C A )
(5-187)
Also, the concentration of A in terms of the initial concentration CAO and fractional conversion XA is C A = C AO (1 − X A )
(5-28)
C AO − C A = C AO X A
(5-27)
or
Substituting Equations 5-27, 5-28, and 5-187 into Equation 5-186 gives uC AO X A = kC AO (1 − X A )(C BO − C AO X A ) VR
(5-188)
Rearranging Equation 5-188, the residence time t can be determined for the conversion of species A in terms of the initial concentrations of species A, B, and the rate constant k as t=
XA k(1 − X A ) (C BO − C AO X A )
(5-189)
With θB = (CBO/CAO) Equation 5-189 becomes t=
XA kC AO (1 − X A ) (θ B − X A )
(5-190)
Equation 5-190 enables the residence time to be determined for a given conversion of A and the initial concentrations of A and B in a
322
Modeling of Chemical Kinetics and Reactor Design
CFSTR. Figure 5-22 illustrates the graphical performance equations for CFSTRs. Example 5-8
A continuous flow stirred tank reactor is used to decompose a dilute solution of species A. The decomposition is irreversible and first order with velocity constant at 2.5 hr–1. The reactor volume is 15 m3. What flowrate of feed solution can this reactor treat if 90% decomposition is required? Solution Assuming a steady state condition (i.e., accumulation = 0)
CFSTR with inflow of component A Th e reaction scheme for the decomposition of A in a CFSTR is represented by A → products, (–rA) = kCA. The mass balance can be written as
uC AO = uC A + ( − rA )VR
or
(5-158)
Introduction to Reactor Design Fundamentals for Ideal Systems
323
Figure 5-22. Graphical representation of the design equations for a CFSTR.
u(C AO − C A ) = kC A VR
(5-191)
The outlet concentration of A in terms of the fractional conversion XA is C A = C AO (1 − X A )
(5-28)
(C AO − C A ) = C AO X A
(5-27)
or
Substituting Equation 5-27 and 5-28 into Equation 5-191 yields uCAOXA = kCAO(1 – XA)VR. The volumetric rate u is
u= =
k(1 − X A ) VR XA 2.5 × (1 − 0.9) × 15 0.9
= 4.17
m3 hr
324
Modeling of Chemical Kinetics and Reactor Design
Example 5-9
The reaction between ammonia (NH3) and formaldehyde (HCHO) to produce hexamine N4(CH2)6 was studied at 36°C (Kermode & Stevens,* 1965) in a CFSTR of 490 dm3 stirred at 1,800 rpm. The reaction is
4 NH 3 + 6HCHO → N 4 (CH 2 )6 + 6H 2 O and the rate equation is
(− r ) = 0.0649C NH 3
2 NH 3 C HCHO
mol dm 3 • sec
The reactants were each fed to the reactor at a rate of 1.5 dm3/sec with an ammonia concentration of 4.02 mol/dm3 and a formaldehyde concentration of 6.32 mol/dm3. Determine the exit concentrations. Solution Assuming steady state condition (i.e., accumulation = 0)
The CFSTR. The reaction in terms of A and B is 4A + 6B → products. Material balance of species A gives uC AO = uC A + ( − rA )VR *
Canad. J. Chem. Eng., 43, 68 (1965).
(5-158)
Introduction to Reactor Design Fundamentals for Ideal Systems
325
where
(− rA ) = 0.0649C NH 3 C2HCHO
mol dm 3 • sec
That is, uC AO = uC A + 0.0649 C A C 2B VR
(5-192)
From stoichiometry: Component
A
B
At time t = 0 At time t = t Amount reacted
CAO CA (CAO – CA)
CBO CB (CBO – CB)
Using
the stoichiometry,
1 1 C AO − C A ) = (C BO − C B ) ( 4 6
(5-193)
with CAO = 4.02 mol/dm3 and CBO = 6.32 mol/dm3. The exit concentration of B can be expressed by CB = CBO – 1.5 (CAO – CA) or
C B = 0.29 + 1.5 C A
(5-194)
The residence time t = VR/u = 490/3.0 = 163.3 sec. Equation 5-192 now becomes C AO = C A + 0.0649tC A C 2B
(5-195)
Substituting Equation 5-194 and the value of the residence time t into Equation 5-192 gives 4.02 = C A + 10.598 C A (0.29 + 1.5C A )
2
(5-196)
Further expansion and rearrangement of Equation 5-196 yields 23.85C 3A + 9.22C 2A + 1.89C A − 4.02 = 0
(5-197)
326
Modeling of Chemical Kinetics and Reactor Design
Equation 5-197 is a polynomial of the third degree, and by employing either a numerical method or a spreadsheet package such as Microsoft Excel, the roots (CA) of the equation can be determined. A developed computer program PROG51 using the Newton-Raphson method to determine CA was used. The Newton-Raphson method for the roots CA of Equation 5-197 is
C A , n +1 = C A , n −
(
f C A, n
(
f ′ C A, n
)
)
(5-198)
Equation 5-197 can be expressed as a function of concentration of A as
f (C A ) = 23.85C 3A + 9.22C 2A + 1.89C A − 4.02
(5-199)
The derivative of Equation 5-199 is f ′(C A ) = 71.55 C 2A + 18.44 C A + 1.89
(5-200)
Substituting Equations 5-199 and 5-200 into Equation 5-198 and using a starting value of the root as 0.25, the solution for the root CA after four iterations was 0.4124. The same result was obtained using Microsoft Excel (see Appendix B). Table 5-11 gives the computer results of program PROG51. Appendix D gives the Newton-Raphson method for solving for the root of an equation.
Table 5-11 Newton-Raphson method for a nonlinear equation
Introduction to Reactor Design Fundamentals for Ideal Systems
327
The exit concentration CA = 0.4124 mol/dm3 and
C B = 0.29 + 1.5 × 0.4124 = 0.9086 mol dm 3
MULTI-STAGE CONTINUOUS FLOW STIRRED TANK REACTOR In a single continuous flow stirred tank reactor, a portion of the fresh feed could exit immediately in the product stream as soon as the reactants enter the reactor. To reduce this bypassing effect, a number of stirred tanks in series is frequently used. This reduces the probability that a reactant molecule entering the reactor will immediately find its way to the exiting product stream. The exit stream from the first stirred tank serves as the feed to the second, the exit stream from the second reactor serves as the feed to the third, and so on. For constant density, the exit concentration or conversion can be solved by consecutively applying Equation 5-158 to each reactor. The following derived equations are for a series of three stirred tanks (Figure 5-23) with constant volume VR. k → B in a battery of three Consider the first order reaction A continuous flow stirred tank reactors, where VR = volume of fluid in each stage (–rAi) = rate of reaction per unit volume in stage i. This changes with i.
Figure 5-23. Battery of continuous flow stirred tank reactors.
328
Modeling of Chemical Kinetics and Reactor Design
Consider the mass balance on key component A Input Output Disappearance = + + Accumulation rate rate by reaction
Accumulation = 0, therefore for the key component A, the mass balance is: Stage 1:
u • C AO = u C A1 + ( − rA1 ) VR
Stage 2:
u • C A1 = uC A 2 + ( − rA 2 )VR
Stage 3:
u • C A 2 = uC A 3 + ( − rA 3 )VR
(5-201)
For the ith stage, the mass balance is: u • C Ai − 1 = u • C Ai + ( − rAi )VR
(5-202)
Dividing Equation 5-202 by u gives
C Ai −1 = C Ai + ( − rAi )
VR u
(5-203)
where t = VR/u = mean residence time of fluid in the stage. Equation 5-203 becomes C Ai − 1 = C Ai + ( − rAi ) t
(5-204)
k Consider the first order reaction A → B in a battery of three continuous flow stirred tank reactors with volumes V1, V2, and V3. The material balance for stage 1 CFSTR is
uC AO = u C A1 + ( − rA1 ) V1
(5-205)
where
(− rA1 ) = kC A1
(5-206)
Introduction to Reactor Design Fundamentals for Ideal Systems
329
Equation 5-205 becomes uC AO = uC A1 + kC A1V1
(5-207)
Rearranging Equation 5-207 with the mean residence time t = V1/u gives C AO (1 + kt1 )
(5-208)
C AO = 1 + kt1 C A1
(5-209)
C A1 = or
The material balance for stage 2 CFSTR is uC A1 = u C A 2 + ( − rA 2 ) V2
(5-210)
Equation 5-210 is further expressed by
uC A1 = u C A 2 + kC A 2 V2
(5-211)
where t 2 = V2/u. The exit concentration CA2 can be determined as CA2 =
C A1 1 ( + kt 2 )
(5-212)
Substituting Equation 5-208 into Equation 5-212 gives CA2 =
C AO (1 + kt1 )(1 + kt 2 )
(5-213)
or
C AO = (1 + kt1 )(1 + kt 2 ) C A2
(5-214)
330
Modeling of Chemical Kinetics and Reactor Design
Where t1 = t 2 = t , Equation 5-214 becomes
C AO 2 = (1 + kt ) C A2
(5-215)
The material balance for a stage 3 CFSTR is u C A 2 = uC A 3 + ( − rA 3 ) V3
(5-216)
Equation 5-216 is further expressed by uC A 2 = u C A 3 + kC A 3 V3
(5-217)
where t 3 = V3/u. The exit concentration CA3 can be determined as C A3 =
CA2 (1 + kt 3 )
(5-218)
Substituting Equation 5-214 into Equation 5-218 gives C A3 =
C AO kt 1 + 1 ( 1 )( + kt 2 )(1 + kt 3 )
(5-219)
Rearranging Equation 5-219 with t1 = t 2 = t 3 = t gives C A3 =
C AO
(1 + kt )3
(5-220)
C AO 3 = (1 + kt ) C A3
(5-221)
or
Example 5-10 k
k
2 → D are conThe pair of reactions A + B 1 → 2C and A + C 3 ducted in a four-stage CFSTR with CAO = 0.9 mol/m , CBO = 0.3 mol/m3,
Introduction to Reactor Design Fundamentals for Ideal Systems
331
and CCO = CDO = 0 mol/m3. The residence time in each stage is 10 minutes. Determine the exit concentrations of A and B in the four CFSTRs. The rate expressions are (–rA) = k1CACB + k2CACC and (–rB) = k1CACB, where k1 = 0.3 m3/ mol•min and k2 = 0.15 m3/mol•min. Solution The following is a battery of continuous flow stirred tank reactors with CAO = 0.9 mol/m3 and CBO = 0.3 mol/m3 in the first tank, and where V1 = V2 = V3 = V4 = VR, u = volumetric flow rate, and the residence time, t = VR/u = 10 mins.
1st CFSTR The material balance on species A is uC AO = uC A1 + ( k1C A1C B1 + k 2 C A1C C )VR
(5-222)
The stoichiometry between species A, B, and C is C C = 3(C BO − C B ) − (C AO − C A ) = 0.9 − 3C B − 0.9 + C A C C = C A − 3C B
(5-223)
Substituting Equation 5-223 into Equation 5-222 gives CAO = CA1 + CA1 t [k1CB1 + k2(CA1 – 3CB1)] or
332
Modeling of Chemical Kinetics and Reactor Design
0.9 = C A1 + 3C A1C B1 + 1.5C A1 (C A1 − 3C B1 )
(5-224)
Material balance on species B is uCBO = uCB1 + k1CA1CB1VR or
0.3 = C B1 + 3C A1C B1
(5-225)
2nd CFSTR Material balance on species A is uC A1 = uC A2 + [k 1 C A2C B2 + k2CA2(CA2 – 3CB2)]VR or
[
]
C A1 = C A 2 + 10 0.3C A 2 C B2 + 0.15C A 2 (C A 2 − 3C B2 )
(5-226)
Material balance on species B is uCB1 = uCB2 + k1CA2CB2VR or C B1 = C B2 + 3 C A 2 C B2
(5-227)
Rearranging Equations 5-226 and 5-227 yields C A 2 + 3C A 2 C B2 + 1.5C A 2 (C A 2 − 3C B2 ) = C A1 C B2 + 3C A 2 C B2 = C B1
(5-228)
3rd CFSTR The material balances on species A and B are
C A 3 + 3C A 3C B3 + 1.5C A 3 (C A 3 − 3C B3 ) = C A 2
C B3 + 3C A 3 C B3 = C B2
(5-229)
4th CFSTR The material balances on species A and B are C A 4 + 3C A 4 C B4 + 1.5C A 4 (C A 4 − 3C B4 ) = C A 3 C B4 + 3C A 4 C B4 = C B3
(5-230)
Introduction to Reactor Design Fundamentals for Ideal Systems
333
There are eight nonlinear equations involving the material balances of species A and B in the four stirred tank reactors. Rearranging these equations yields the following: 1.5 C 2A1 − 1.5 C A1 C B1 + C A1 − 0.9 = 0 3C A1C B1 + C B1 − 0.3 = 0
1.5 C 2A 2 − 1.5 C A 2 C B2 + C A 2 − C A1 = 0 3C A 2 C B2 + C B2 − C B1 = 0 1.5 C 2A 3 − 1.5 C A 3 C B3 + C A 3 − C A 2 = 0 3C A 3C B3 + C B3 − C B2 = 0 1.5 C 2A 4 − 1.5 C A 4 C B4 + C A 4 − C A 3 = 0 3C A 4 C B4 + C B4 − C B3 = 0
(5-231)
A computer program PROG52 was developed using the NewtonRaphson’s method to determine the outlet concentrations of species A and B from the four stirred tank reactors. The eight Equations 5-231 are supplied as functions in the subroutine of PROG52 as: F(1) = 1.5 * X(1) * X(1) − 1.5 * X(1) * X(2) + X(1) − 0.9
F(2) = 3.0 * X(1) * X(2) + X(2) − 0.3 F(3) = 1.5 * X(3) * X(3) − 1.5 * X(3) * X( 4) + X(3) − X(1) F( 4) = 3.0 * X(3) * X( 4) + X( 4) − X(2)
F(5) = 1.5 * X(5) * X(5) − 1.5 * X(5) * X(6) + X(5) − X(3) F(6) = 3.0 * X(5) * X(6) + X(6) − X( 4) F(7) = 1.5 * X(7) * X(7) − 1.5 * X(7) * X(8) + X(7) − X(5)
F(8) = 3.0 * X(7) * X(8) + X(8) − X(6)
334
Modeling of Chemical Kinetics and Reactor Design
where CA1 = X(1), CB1 = X(2); CA2 = X(3), CB2 = X(4); CA3 = X(5), CB3 = X(6); CA4 = X(7), CB4 = X(8). The exit concentrations of species A and B from the computer results and the initial guesses of CA1 = 0.1, CB1 = 0.1, CA2 = 0.1, CB2 = 0.1, CA3 = 0.1, CB3 = 0.1, CA4 = 0.1, CB4 = 0.1 are:
C A1 = X(1) = 0.54599, C A 2 = X(3) = 0.3703, C A 3 = X(5) = 0.2718, C A 4 = X(7) = 0.21107,
C B1 = X(2) = 0.11372 C B2 = X( 4) = 0.05386 C B3 = X(6) = 0.02958 C B4 = X(8) = 0.01792
The computer program PROG52 can be used to solve any number of nonlinear equations. The partial derivatives of the functions are estimated by the difference quotients when a variable is perturbed by an amount equal to a small value (∆) used in the program to perturb the X-values.
EQUAL SIZE CFSTR IN SERIES Consider a system of N continuous flow stirred tank reactors in series as shown in Figure 5-24. Although the concentration is uniform from one tank to another, there is a change in concentration as the fluid traverses between the CFSTRs. This is illustrated in Figure 5-25. The drop in concentration implies that the larger the number of CFSTRs in series, the closer the system would behave as plug flow.
Figure 5-24. System of N equal size CFSTRs in series.
Introduction to Reactor Design Fundamentals for Ideal Systems
335
Figure 5-25. Concentration profile through an N stage CFSTR system.
A general equation can be derived for the exit concentration CAN as follows. The material balance for stage i CFSTR is u C Ai −1 = uC Ai + ( − rAi ) Vi
(5-202)
Equation 5-202 is further expressed by uC Ai −1 = u C Ai + kC Ai Vi
(5-232)
where t i = Vi/u. Equation 5-232 becomes C Ai = or
C Ai −1 (1 + kt i )
(5-233)
336
Modeling of Chemical Kinetics and Reactor Design
C Ai −1 = 1 + kt i C Ai
(5-234)
For N equal size mixed flow reactors in series, a general equation for the exit concentration CAN is C AN −1 = C AN + kC AN t N
(5-235)
which becomes C AN =
C AN −1 C AO = (1 + kt N ) (1 + kt N )N
(5-236)
or C AO N = (1 + kt N ) C AN
(5-237)
Rearranging Equation 5-237, the residence time distribution for the system is
N C t N, reactors = Nt i = AO k C AN
1N
− 1
(5-238)
Using the limit where N → ∞, Equation 5-238 reduces to the plug flow equation t plug =
1 C AO ln k CA
(5-239)
For most types of kinetics, the stepwise changes in concentration results in a smaller average reaction rate than it would otherwise if the same feed materials were in a batch or plug (tubular) reactor. Therefore, to obtain the same output the volume of the reaction space must be larger, and in some instances much larger as in the case where only a single tank is used. By arranging several tanks in series the
Introduction to Reactor Design Fundamentals for Ideal Systems
337
volume of the reaction space can be substantially reduced, as illustrated in Figure 5-25. However, the volume per unit of output will still be greater than is required for either a batch or tubular reactor. Using several CFSTR systems in series, some of the desired characteristics of the CFSTR system can be achieved, such as good mixing and heat transfer and easier and less expensive maintenance, while at the same time approaching the performance of a tubular system. However, this can be offset by the cost of using several smaller reactors, which will be greater than the cost of a single larger reactor. In such cases, there may be some economic tradeoff between reactor size and cost. SECOND ORDER REACTION IN A CFSTR Consider the second order reaction of two components A + B → products, θA = CBO/CAO, where
(− rA )
=
(− rB )
= kC A C B = kC 2A
(5-240)
When the reactant ratio is unity (i.e., θA = 1), the mass balance for component A in the continuous flow stirred tank reactor is
uC AO = uC A + ( − rA ) VR + VR
dC A dt
(5-241)
where accumulation is zero VRdCA/dt = 0 and Equation 5-241 becomes uC AO = uC A + kC 2A VR
(5-242)
where t = VR/u. Equation 5-242 becomes C AO = C A + ktC 2A
(5-243)
Rearranging Equation 5-243 gives ktC 2A + C A + C AO = 0
(5-244)
Equation 5-244 is a quadratic equation of the form ax2 + bx + c = 0, where the root of the equation is
338
x=
Modeling of Chemical Kinetics and Reactor Design
− b ± ( b 2 − 4ac)
0.5
2a
The exit concentration CA for the second order reaction is CA =
−1 + (1 + 4 ktC AO ) 2 kt
0.5
(5-245)
nth order kinetics in a CFSTR. The nth order kinetics in a CFSTR, as represented by (–rA) = kCnA, yields u C AO = uC A + ( − rA ) VR n uC AO = uC A + kC A VR
(5-246)
Rearranging Equation 5-246 gives n ktC A + C A − C AO = 0
(5-247)
where t = VR/u. Equation 5-247 is a polynomial, and the roots (CA) are determined using a numerical method such as the Newton-Raphson as illustrated in Appendix D. For second order kinetics, the positive sign (+) of the quadratic Equation 5-245 is chosen. Otherwise, the other root would give a negative concentration, which is physically impossible. This would also be the case for the nth order kinetics in an isothermal reactor. Therefore, for the nth order reaction in an isothermal CFSTR, there is only one physically significant root (0 < CA < CAO) for a given residence time t . Example 5-11
(1) For a cascade of N CFSTRs of equal volume, VR, in which the k → P occurs with a throughput u, first order forward reaction A show that the system fractional conversion is
1−
1 N 1 + kVR u
Introduction to Reactor Design Fundamentals for Ideal Systems
339
whatever the feed concentration of A. (2) A sample CFSTR of volume VR has one inlet stream rate u, containing A at concentration CAO and a second inlet stream of rate k → 2P αu, containing B at concentration CBO. The reaction is A + B with the rate first order with respect to both A and B. Obtain an expression for the concentration of A at the reactor exit in terms of VR and the conditions in the feed streams. Solution (1) Considering the material balance on species A in the first CFSTR at constant density gives uC AO = uC A1 + (–r A)V R where (–rA) = kCA: uC AO = uC A1 + kC A1VR
Rearranging yields C A1 =
C AO kVR 1 + u
For the second CFSTR, the exit concentration CA2 is
CA2 =
C AO C A1 = kVR kVR 2 1+ 1 + u u
For the Nth CFSTR, Equation 5-237 gives C AN =
C AN −1 C AO = kVR kVR N 1+ 1 + u u
C AN 1 = N where C AO 1 + kVR u
340
Modeling of Chemical Kinetics and Reactor Design
C AN The fractional conversion XA = 1 – C is AO
=1 −
1 N 1 + kVR u
(2) A CFSTR with two inlets Aand B is shown below.
k → 2 P and the rate expression of species A The reaction A + B or B is (–rA) = (–rB) = kCACB. The material balance on species A is
uC AO = u(1 + α )C A + ( − rA ) VR uC AO = u(1 + α )C A + kC A C B VR
or
CA =
uC AO u(1 + α ) + kVR C B
The material balance on species B is αuC BO = u(1 + α )C B + ( − rB ) VR αuC BO = u(1 + α )C B + kC A C B VR
or
(5-248)
Introduction to Reactor Design Fundamentals for Ideal Systems
CB =
uαC BO [u(1 + α) + kC A VR ]
341
(5-249)
Substituting Equation 5-249 into Equation 5-248 gives CA =
uC AO
αuC BO u(1 + α ) + kVR u(1 + α ) + kC A VR
(5-250)
Rearranging Equation 5-250 gives
{
}
(1 + α )kVR C 2A + u(1 + α )2 + (αC BO − C AO )kVR C A − u(1 + α )C AO = 0
(5-251)
Equation 5-251 is a quadratic equation of the form ax2 + bx + c = 0, where the root of the equation is
x=
− b ± ( b 2 − 4ac)
0.5
2a
Therefore, the exit concentration of species A in terms of VR and the conditions in the feed streams (α, u, CAO, CBO) is
[
− u(1 + α ) + (αC BO − C AO )kVR
CA =
+
2
[u(1 + α)
2
]
+ (αC BO − C AO )kVR
] + 4u(1 + α) kC 2
2
AO VR
2(1 + α )kVR
INTERMEDIATE CONVERSION OF N – 1 CFSTR Consider a series of continuous flow stirred tank reactors of equal size with inlet and exit conversions as X0 and XN. The intermediate optimal conversions X1, X2, X3 . . . Xi . . . XN–1 can be determined, which will minimize the overall reactor size. Levenspiel [1] has shown
342
Modeling of Chemical Kinetics and Reactor Design
that the optimum size ratio of CFSTRs is achieved from the plot of 1/(–rA) versus XA, when the slope of the rate curve at point Xi equals the diagonal of the rectangle, as this gives both the intermediate conversion as well as the size of the units. Adesina [2] has employed a numerical method to determine the optimum (N – 1) intermediate conversions, which also minimizes the overall reactor size for a series of N equal-sized stirred tanks. Adesina’s methodology depends on the rate expression being differentiated twice. The following determines the intermediate conversions X1, X2, X3 . . . Xi . . . XN–1 of a series of N – 1 equal-sized continuous flow stirred tank reactors. For the first CFSTR the optimal selection of the conversion X1 on the 1/(–rA) versus XA plot is such that the diagonal of the rectangle must possess the same slope as the tangent to the curve at point X1 (Figure 5-26). Therefore, the first CFSTR gives
Figure 5-26. Maximization of rectangle applied to find the optimum intermediate conversion and optimum sizes of mixed flow reactors in series.
Introduction to Reactor Design Fundamentals for Ideal Systems
f ( X 2 ) − f ( X1 ) df ( X ) = X1 − X 0 dX X1
343
(5-252)
where f(X) = 1/(–rA) and x1 means that the slope is evaluated at X1. Rearranging Equation 5-252 gives w1 = f(X2) – f(X1) – Ψ(X1)(X1 – X0) = 0. For the second and third CFSTRs: w 2 = f ( X 3 ) − f ( X 2 ) − Ψ( X 2 )( X 2 − X1 ) = 0
w 3 = f ( X 4 ) − f ( X 3 ) − Ψ( X 3 )( X 3 − X 2 ) = 0 For the ith CFSTR: w i = f ( X i +1 ) − f ( X i ) − Ψ( X i )( X i − X i −1 ) = 0
For the (N – 1)th CFSTR: w N −1 = f ( X N ) − f ( X N −1 ) − Ψ( X N −1 )( X N −1 − X N − 2 ) = 0
(5-253)
The simultaneous solution of Equation 5-253 yields the unknown intermediate conversions X1, X2, X3 . . . Xi . . . XN–1, where the optimal size is (V/FAO)i for the ith reactor. V = ( X i − X i −1 )Ψ( X i ), i = 1, 2, ........N FAO i
(5-254)
and Ψ(X) = [df(X)/dX], where V = reactor volume, liter, m3 FAO = feed molar rate, mol/min Using the Newton-Raphson method for solving the nonlinear system of Equations 5-253 gives
(
) (
γ ( m ) = X ( m ) − X ( m −1) = − J −1 X ( m −1) w X ( m −1) m = 1, 2,.........
) (5-255)
344
Modeling of Chemical Kinetics and Reactor Design
where X(m) is the column vector of conversions at the mth iteration. This is noted as
[
X ( m ) = X1( m ) X (2m ) X (3m ) ................X (Nm−)1
]
T
(5-256)
X(0) is the guessed initial conversion vector, and the Jacobian matrix at the (m – 1)th iteration, J(X(m–1)), has the dimension of (N – 1) × (N – 1). Equation 5-255 has a quadratic convergent property, which gives the final solution after few iterations. The convergence criterion is: X (i m ) − X (i m −1) ∑ X( m ) i =1 i N N
2
≤ ε = 10 −2
(5-257)
The Jacobian matrix is tri-diagonal since the elements are ∂w i = 0 i = 1, 2, .............( N − 1) q = 1, 2,......(i − 2) ∂X q
∂Ψ( X i ) ∂w i − 2 Ψ( X i ) = ( X i −1 − X i ) ∂X i ∂X i ∂w i = Ψ ( X i −1 ) ∂X i −1 ∂w i = Ψ ( X i +1 ) ∂X i +1
∂w i = 0 p = i + 2, i + 3,............( N − 1) ∂X p and is represented by
(5-258)
Introduction to Reactor Design Fundamentals for Ideal Systems
∂w1 ∂X 1 ∂w 2 ∂X1 0 J( X ) = : 0 : 0
∂w1 ∂X 2 ∂w 2 ∂X 2 ∂w 3 ∂X 2 :
0
..
∂w 2 ∂X 3 ∂w 3 ∂X 3 :
∂w 3 ∂X 4 :
:
∂w i ∂X i −1 :
∂w i ∂X i :
..
0
∂w N −1 ∂X N − 2
0
..
0 0 : ∂w i ∂X i +1 : ∂w N −1 ∂X N −1
345
0
(5-259)
Adesina has shown that it is superfluous to carry out the inversion required by Equation 5-255 at every iteration of the tri-diagonal matrix J. The vector γm is readily computed from simple operations between the tri-diagonal elements of the Jacobian matrix and the vector. The methodology can be employed for any reaction kinetics. The only requirement is that the rate expression be twice differentiable with respect to the conversion. The following reviews a second order reaction and determines the intermediate conversions for a series of CFSTRs. Example 5-12
Styrene (A) and butadiene (B) are to be treated in a series of CFSTRs each possessing 26.5 m3 capacity. The initial concentration of A is 0.795 and B is 3.55 kg mol/m3. The flowrate is 20 m3/hr. The rate equation is (–rA) = 0.036CACB kg • mol/m3 – hr. Determine the intermediate conversions, if the eleventh stirred tank is required to effect 80% conversion of the limiting reactant. Solution Assume that the reaction between A and B is second order and is represented by A + B → products where A is the limiting reactant. The rate expression is
346
Modeling of Chemical Kinetics and Reactor Design
(− rA ) = kC A C B
(5-240)
From the stoichiometry, CAO – CA = CBO – CB and CB = CBO – (CAO – CA). The fractional conversion XA of A is XA = (CAO – CA)/ CAO or CAO – CA = CAOXA. Therefore, CA in terms of the fractional conversion XA and initial concentration CAO is CA = CAO(1 – XA) and C B = C BO − (C AO − C A ) = C BO − C AO X A where θB = CBO/CAO. The concentration of B is CB = CAO(θB – XA). Substituting the concentrations of A and B in Equation 5-240 gives
(− rA ) = kC2AO (1 − X A ) (θB − X A )
(5-260)
Equation 5-260 is used to determine the intermediate conversions X1, X2, X3, . . . X10. This is accomplished first by determining the inverse of Equation 5-260, and then differentiating the inverse function twice with respect to the fractional conversion XA. Hence, the inverse of Equation 5-260 is 1 1 = 2 (− rA ) kC AO (1 − X A )(θB − X A )
(5-261)
Differentiating Equation 5-261 with respect to XA yields
(1 − X A ) + (θB − X A ) d 1 = 2 dX A ( − rA ) kC AO (1 − X A ) (θ B − X A )
[
]2
(5-262)
Further differentiation of Equation 5-262 gives after mathematical manipulations using any of the calculus of either the product or quotient involving two variables d dv du ( uv) = u + v dx dx dx
or
Introduction to Reactor Design Fundamentals for Ideal Systems
d u = dx v
d dX A =
v
347
du dv −u dx dx v2
d 1 dX A ( − rA )
2 kC 2AO
[
] [
]
(1 − X A ) + (θ B − X A ) 2 − (1 − X A )(θ B − X A ) (1 − X A )(θB − X A ) 3
[
]
(5-263)
Equations 5-261, 5-262, and 5-263 are incorporated as functions in the computer program CFSTR51. They are represented by RATE( XX ) = CONST1* CAO **2 * (1 − XX ) * (THETAB − XX )
RATEINV( XX ) = 1 RATE( XX ) DER( XX ) = ((1.0 − XX ) + (THETAB − XX )) /
(CAO **2 * CONST1 * ((1.0 − XX) * (THETAB − XX)) **2)
DDER( XX ) = 2 *
(((1.0 − XX) + (THETAB − XX))) **2 )
– ((1.0 − XX ) * (THETAB − XX )) /
(CAO **2 * CONST1 * ((1.0 − XX) * (THETAB − XX)) **3)
Known values of CAO, CBO, and k, and guessed values of the intermediate conversions X1, X2, X3, . . . X10 are given as data in the computer program. The results are obtained after a few iterations and are shown in Table 5-12. GRAPHICAL SOLUTION OF THE CASCADE OF N – CFSTR IN SERIES The CFSTR equation of the nth stage
uC A, n −1 = uC A, n + ( − rA )n VR
(5-235)
348
Modeling of Chemical Kinetics and Reactor Design
Table 5-12 Results of the intermediate conversions in a reactor train of CFSTRs involving the second order irreversible reaction kinetics A + B → products
can be rearranged in the form
(− rA )n = − t1 C A, n + n
1 C A , n −1 tn
or
(− rA )n
C A , n −1 − C A , n
=
1 tn
(5-264)
where t n is the mean residence time. At a given inlet concentration, CA,n–1, Equation 5-264 is linear in exit concentration. A plot of (–rA) versus CA for the limiting component A is shown in Figure 5-27. Equation 5-264, on arrangement,
Introduction to Reactor Design Fundamentals for Ideal Systems
349
Figure 5-27. Graphical representation of a number of CFSTRs in series.
can be viewed as a slope of –1/ t n , which intersects the abscissa (X-axis) at the point representing the inlet concentration. The abscissa of the point where this straight line intersects the (–rA) versus CA curve gives the exit concentration for each stage in the cascade. This represents the inlet to the next stage. If the size of the cascade reactor is the same (i.e., V1 = V2 = . . . VN), then the residence time is the same throughout the system, and the straight lines are parallel. The procedure is repeated until the desired concentration is obtained. The number of parallel lines drawn until the final concentration is reached gives the number of stages required for the desired conversion. In many cases, t n must be estimated because the purpose is to move from CAO to CAN in about four or five stages.
SPACE TIME (ST) AND SPACE VELOCITY (SV) Space time and space velocity are used to determine the performance of flow reactors. Space velocity, SV, is defined as FA/VCAO, that is,
350
Modeling of Chemical Kinetics and Reactor Design
SV =
uC AO FA = VC AO VC AO
The term V/FA for flow reactors is used to evaluate the size of the reactor required to achieve the conversion XA of a reactant feed rate FA. It is the number of reactor volumes of feed at specified conditions that can be treated in unit time, where FA is the molar flowrate (uCAO) and V is the volume of the reactor. Space time, ST, is defined as the time required to process one reactor volume of feed measure at specified conditions. The relationship between space velocity SV and ST is as follows: If CAO is the concentration of the reactant in the feed, then FA = uCAO and
V V = FA uC AO or V V = C AO u FA moles of A entering mol ( volume of reactor ) 3 × m 3 volume of feed m = mol moles of A entering sec time The ratio of V/u has the unit of time and its reciprocal u/V is called the space velocity:
ST =
V reactor volume u volumetric feed rate
The space velocity SV is often used with conversion to describe the overall reactor performance. It is common in the petroleum and petrochemical industries to plot conversion against space velocity to describe the effect of feed rate on the performance of a flow system.
Introduction to Reactor Design Fundamentals for Ideal Systems
351
The reactor feed may be preheated and the feed pressure may alter. The volumetric flowrate of gases depends on the reactor temperature and pressure at fixed mass flowrate. In many cases, the feed is liquid at room temperature, while the reaction mixture is a gas at the higher temperature in the reactor. In these instances, the performance of the reactor is represented as conversion and selectivity against the liquid hourly space velocity (LHSV). This is defined as LHSV =
volume of liquid feed per hour volume of reactor
Another commonly used term is the gas hourly space velocity (GHSV), which is defined as GHSV =
volume of gaseous feed per hour volume of reactor
For gaseous feeds, space velocity SV is normally determined in terms of volumes measured at standard conditions T = 25°C and P = 1.013 bar. Space time ST is equal to the residence time in a plug flow reactor only if the volumetric flowrate remains constant throughout the reactor. The residence time depends on the change in the flowrate through the reactor, as well as V/u. The change in u depends on the variation in temperature, pressure, and the number of moles. The concept of SV with conversions in the design of a plug flow reactor is discussed later in this chapter.
FRACTIONAL CONVERSION, YIELD, AND SELECTIVITY IN REACTORS Consider the following reactions, namely the second order irreversible reaction aA + bB → rR + sS, the series reaction A → Β → C, and the parallel reaction A → Β A → C Fractional conversion, XA In the above reactions, the fractional conversion is defined as conversion =
loss of reactant feed of reactant
352
Modeling of Chemical Kinetics and Reactor Design
For reactant A, the conversion is
XA =
N AO − N A FAO − FA = NA FAO
At constant density (i.e., the volume is constant), XA is defined as
XA =
C AO − C A C AO
Selectivity Selectivity is defined as the ratio of the desired product to the amount of limiting reactant that has undergone chemical change. That is
SR =
amount of desired product amount of limiting reactant that has undergone chemical change
For the second order irreversible reaction, the selectivity of species R is
SR =
NR N AO − N A
where NAO, NA = moles of reactant A NR = moles of product R If the system is at constant density, then the selectivity of species R is SR =
CR C AO − C A
For the series A → Β → C and parallel reaction A → Β A → C, the selectivity of the wanted species B is
SB =
NB N AO − N A
If the system is at constant density, SB is defined as
Introduction to Reactor Design Fundamentals for Ideal Systems
SB =
CB C AO − C A
SB =
CB C B + CC
353
or
Yield The yield of the product is the amount of the desired product formed divided by the amount of the reactant fed. That is YR =
desired product formed reactant fed
For the reaction aA → rR, the yield is defined by a C YR = R r C AO where a and r are the stoichiometric coefficients, C R is the concentration of the desired product, and CAO is the inlet concentration of the reactant. For the series reaction A → Β → C and parallel reaction A → Β A → C, the yield of the desired product (B) is
YB =
CB C AO
RELATIONSHIP BETWEEN CONVERSION, SELECTIVITY, AND YIELD A relationship between the yield, selectivity and conversion can be obtained on the components as follows. The conversion XA of component A is XA =
C AO − C A C AO
354
Modeling of Chemical Kinetics and Reactor Design
The yield of component B is
CB C AO
YB =
and the selectivity of component B is
SB =
CB CB = C B + C C C AO − C A
Therefore, YB =
C AO − C A CB CB = = SB • X B C AO C AO − C A C AO
Therefore, YB = SB • X B
(5-265)
For a well-stirred tank reactor involving a second order irreversible reaction of the form aA + bB → rR + sS, the yield of R is
YR =
a C AO − C A CR a CR • = • C AO r C AO − C A r C AO
a = SR • X B r
(5-266)
For a plug flow or batch reactor, the yield of component R is defined as 1 YR = − C AO
CA
∫
C AO
YR dC A =
XA
∫
YR • dX A
(5-267)
0
For a cascade of well-stirred reactors, the yield of component R is defined as
Introduction to Reactor Design Fundamentals for Ideal Systems
YR =
1 N 1 YR, i ∆( A )i = ∑ C AO ( A ) i =1
355
N
∑ YR, i (C Ai − C A,i −1 )
(5-268)
i =1
SELECTIVITY The concept of selectivity and its application are essential in the industrial evaluation of complex chemical reactions when the objective is to attain maximum production of the desired product. In industrial operations, the goal is to establish the best operating conditions for the desired product. In complex chemical reactions, two or more products are produced whose formation may interfere with the generation of the desired product. In such cases, production is improved of the desired product by employing the selectivity concept to either accelerate its reaction rate or suppress the formation rates of undesired products. This procedure may be performed by examining a single expression for selectivity instead of examining the effect of appropriate reaction parameters on individual rate equations. This is referred to as selectivity maximization because it is a search for the maximum value of selectivity within the permissible range of process parameters. This value determines the optimum operational conditions for the desired products. The following details mathematical expressions for instantaneous (point or local) or overall (integral) selectivity in series and parallel reactions at constant density and isothermal conditions. An instantaneous selectivity is defined as the ratio of the rate of formation of one product relative to the rate of formation of another product at any point in the system. The overall selectivity is the ratio of the amount of one product formed to the amount of some other product formed in the same period of time. k k2 → C occurring in a batch Consider a series reaction A 1 → B system at constant volume with CAO ≠ 0, and CBO = CCO = 0. The rate equations for these reactions are
dC A = − k1C A dt
(5-269)
dC B = k1C A − k 2 C B dt
(5-270)
356
Modeling of Chemical Kinetics and Reactor Design
dC C = k 2CB dt
(5-271)
The equations of components A, B, and C when integrated are C A = C AO e − k1t
CB =
(5-272)
(
k1C AO − k1t − k 2 t e −e k 2 − k1
)
(5-273)
and k2 k1 C C = C AO 1 − e − k 1t + e−k2t k 2 − k1 k 2 − k1
(5-274)
If component B is the desired product and C is unwanted, the instantaneous selectivity of B relative to C is expressed as SBC from Equations 5-270 and 5-271 as
SCB =
dC B dt dC C dt
=
k1C A − k 2 C B k 2CB
=
k1C A −1 k 2CB
(5-275)
The overall selectivity of B relative to C, SCB is SCB = CB/CC from Equations 5-273 and 5-274 is SCB =
(
)
e − k 1t − e − k 2 t k1 k2 k 2 − k1 k1 e − k 1t + e−k2t 1 − k 2 − k1 k 2 − k1
(5-276)
In certain instances, the concentrations of reaction participants in the rate and product distribution equation are expressed in terms
Introduction to Reactor Design Fundamentals for Ideal Systems
357
of concentrations of one selected reactant. In the series reaction k k2 A 1 → B → C , dividing Equation 5-270 by 5-271 yields dC B k 2 C B = −1 dC A k1C A
(5-277)
Integrating Equation 5-277 by substituting CB/CA and subsequent manipulation yields k2 k1C AO C A C A k1 CB = − k 2 − k1 C AO C AO
(5-278)
The concentration of component C by material balance gives C C = C AO − C A − C B k2 k1 k C k C 2 1 A A = C AO 1 − + k 2 − k1 C AO k 2 − k1 C AO
(5-279)
Similarly, for a parallel reaction, in which all the steps are of the same order
with CAO ≠ 0, CBO = CCO = 0. The rate equations are dC A = − ( k1 + k 2 )C A dt
(5-280)
358
Modeling of Chemical Kinetics and Reactor Design
dC B = k1C A dt
(5-281)
dC C = k 2C A dt
(5-282)
Integrating Equation 5-280 gives C A = C AO e − ( k1 + k 2 ) t
(5-283)
Substituting Equation 5-283 into Equation 5-281 gives
dC B = k1C AO e − ( k1 + k 2 ) t dt
(5-284)
Integrating Equation 5-284 with the boundary conditions gives
CB =
[
]
(5-285)
[
]
(5-286)
k1C AO 1 − e −( k1 + k 2 )t k1 + k 2
Similarly,
CC =
k 2 C AO 1 − e −( k1 + k 2 )t k1 + k 2
The instantaneous selectivity of B relative to C is SBC SCB =
dC B dt k1C A k1 = = dC C dt k 2 C A k 2
The overall selectivity of B relative to C is SBC
SCB =
C B k1 = CC k 2
(5-287)
This shows that both the instantaneous and the overall selectivity of B relative to C are the same, and depends only on k1 and k2. The two selectivities differ for most complex reactions.
Introduction to Reactor Design Fundamentals for Ideal Systems
359
Selectivity of a Parallel Reaction in a CFSTR Consider the first order parallel reaction
in a well-mixed stirred tank. The mass balance on component A is
uC AO = uC A + ( − rA )VR uC AO = uC A + ( k1 + k 2 )C A VR
[
C AO = C A 1 + ( k1 + k 2 ) t
]
The residence time t is t=
C AO − C A ( k1 + k 2 ) C A
The exit concentration of A is CA =
C AO 1 + ( k1 + k 2 ) t
[
]
(5-288)
The exit concentrations of B and C in terms of CAO are
C B = k 1t CC = k 2 t
C AO 1 + ( k1 + k 2 ) t
[
C AO 1 + ( k1 + k 2 ) t
[
]
(5-289)
]
(5-290)
The instantaneous and the overall selectivity of B relative to C are the same and are expressed as
360
Modeling of Chemical Kinetics and Reactor Design
SCB = SCB =
k1 k2
(5-291)
Reaction Characteristics in Defining Selectivities In developing mathematical expressions for selectivities, knowledge of the rate equations are required. This is because the instantaneous selectivity is defined in terms of the rate ratios. The parameters that affect the instantaneous and the overall selectivities are exactly the same as those influencing the reaction rates, namely, the concentration, temperature, activation energy, time of reaction (residence time in flow reactors), catalysts, and the fluid mechanics. Effect of Temperature on Selectivity For the various reaction mechanisms used in determining both instantaneous and the overall selectivities, selectivity depends on the energy of activation obtained from the Arrhenius equation [(k = koexp(–E/RT)], the temperature, initial concentration, and the time of reaction. From the Arrhenius equation, the specific reaction rate k is an integral part of the selectivity expressions. Furthermore, analyzing selectivity expressions may indicate an enhanced effect of the temperature on selectivity. Maximizing the expressions for both instantaneous and overall selectivities may depend on the following: • The time of reaction at constant temperature. • The temperature at constant time of reaction. • Both the time and temperature. Example 5-13
A well-mixed batch reactor is used for performing the isothermal liquid phase reaction
Introduction to Reactor Design Fundamentals for Ideal Systems
361
Each reaction step is first order with respect to reactant A and the initial concentration of A is 1.0 kmol/m3. (1) Determine the yield of B with respect to A for any given initial concentration. (2) Determine the time required to achieve a 60% conversion of A to B or C. Solution (1) Assuming the reaction is first order in a constant volume batch system, the rate equations of A, B, and C, respectively, are:
(− rA )net =
dC A = − ( k1 + k 2 ) C A dt
(5-280)
(+ rB ) =
dC B = k1C A dt
(5-281)
(+ rC ) =
dC C = k 2C A dt
(5-282)
Integrating Equation 5-280 between the boundary conditions t = 0, CA = CAO and t = t, CA = CA gives C A = C AO e − ( k1 + k 2 ) t
(5-283)
Substituting Equation 5-283 into Equation 5-281 gives dC B = k1C AO e − ( k1 + k 2 ) t dt
(5-284)
Integrating Equation 5-284 between the boundary conditions gives
CB =
{
k1C AO 1 − e −( k1 + k 2 ) t k1 + k 2
}
The yield of B with respect to A is YB
(5-285)
362
Modeling of Chemical Kinetics and Reactor Design
YB =
CB C AO
1 − e −( k1 + k 2 )t k1 C AO = • C AO ( k1 + k 2 )
{
}
{
}
=
k1 • 1 − e −( k1 + k 2 ) t + k k ( 1 2)
Substituting the values of k1 and k2 in terms of time t gives the yield of B with respect to A as YB = 0.8(1 – e–2.5t). (2) The time required to achieve 60% conversion of A to B or C is Conversion of A, X A = 1 −
CA = 0.6 C AO
CA = 0.4 = e − ( k1 + k 2 ) t C AO
C ln A = ln(0.4) = − ( k1 + k 2 ) t C AO That is,
ln 0.4 = − 2.5 t t = 0.366 hr (≈22 min)
PLUG FLOW REACTOR For a tubular (plug flow) reactor, the conditions at any point in the reactor are independent of time, and the linear velocity v of the reacting mixture is the same at every point in a cross-section S perpendicular to the flow direction and equal to (G/ρS). The composition of the reaction mixture depends on the distance L from the inlet point.
Introduction to Reactor Design Fundamentals for Ideal Systems
363
A tubular plug flow (Figure 5-28) reactor assumes that mixing of fluid does not take place, the velocity profile is flat, and both temperature and composition are uniform at any cross-section in the reactor. At any instant, because gas-phase reactions are often carried out in tubular systems, the mass flowrate G and C ′i the concentration of i in moles per unit mass is used. The mass flowrate G does not change with position when fluid density changes as is the case with u, the volumetric flowrate (Figure 5-29). Consider the reaction A → Products, where A is the key reactant. (–rA) = Net rate of disappearance of A by reaction per unit volume [moles/(unit time, unit volume)]
Figure 5-28. A tubular (plug flow) reactor.
Figure 5-29. Piston flow reactor differential element.
364
Modeling of Chemical Kinetics and Reactor Design
The following assumptions should be made: • There is a steady state operation (i.e., no change with time in the system) • Plug flow • The system operates isothermally (i.e., the rate constant does not change with l) Now consider the mass balance for reactant A over the control volume Sδl. Concentration of A
l + δl
l C ′A . . . ( − rA )
Rate of reaction
C ′A +
(− rA ) +
dC ′A δl +. . . dl
d( − rA ) δl dl
+. . .
The average rate of reaction is given by the arithmetic mean of the rates at l and l + δl. That is,
(− rA )average = (− rA )l
+
1 d ( − rA )l δl + ....... dl 2
(5-286)
Since there is a steady state operation, INPUT RATE = OUTPUT RATE
dC ′ By flow: GC ′A = G C ′A + A δl + ... dl 1 d( − rA )l + ( − rA )l + δl + ...S δl 2 dl mass • moles time mass
(5-287)
Introduction to Reactor Design Fundamentals for Ideal Systems
365
Equation 5-287 reduces to −G
dC ′A 1 d ( − rA )l δl δl = ( − rA )l + Sδl dl dl 2
(5-288)
As δl → 0, (1/2)[d(–rA)l/dl]δl becomes increasingly small and Equation 5-288 then becomes
−
G dC ′A = ( − rA ) S dl
(5-289)
Consider the case where both volumetric flowrate u and density ρ are constant. A relationship between the mass flowrate G and the volumetric flow is: G = u•ρ
(5-290)
By definition, C A = C ′A • ρ
(5-291)
That is, moles moles mass = × unit volume unit mass unit volume
Differentiating Equation 5-291 gives
dC A = ρ• dC ′A
(5-292)
or dC ′A =
dC A ρ
(5-293)
Substituting Equations 5-290 and 5-293 into Equation 5-289 gives −
u • ρ dC A • = ( − rA ) S ρ dL
(5-294)
366
Modeling of Chemical Kinetics and Reactor Design
or
(− rA ) = − Su •
dC A dL
(5-295)
where the average flow velocity in the reactor is u length ≡ vL S time
Equation 5-295 becomes
(− rA ) = − v L •
dC A dL
(5-296)
Separating the variables and integrating Equation 5-296 with the limits at L = 0, CA = CAO and at L = L, CA = CAF, Equation 5-296 becomes
−
C AF
∫
C AO
dC A 1 = (− rA ) v L
L
∫ dL
(5-297)
0
or −
C AF
dC
∫ (− rAA) = C AO
L vL
(5-298)
where L is the total length of the reactor and the reactor volume, vR = S • L. L length = ≡ t , mean residence time v L length time
t≡
V L L •S = = R , plug flow vL vL • S u
Substituting Equation 5-299 into Equation 5-298 gives
(5-299)
Introduction to Reactor Design Fundamentals for Ideal Systems
367
C
t plug flow =
AF VR dC A = − ∫ u (− rA ) C
(5-300)
AO
or volume of plug flow reactor is
VR plug flow = − u
C AF
dC
∫ (− rAA) C
(5-301)
AO
In terms of the fractional conversion XA, that is
XA =
C AO − C A C AO
(5-13)
Rearranging Equation 5-13 gives
C A = C AO (1 − X A )
(5-28)
Differentiating Equation 5-28 gives dC A = − C AO dX A
(5-29)
Substituting Equation 5-29 into Equation 5-296 gives
(− rA ) = v L C AO
dX A dL
(5-302)
Integrating Equation 5-302 between the limits at L = 0, X = 0 and L = L, X = XA, and rearranging yields L
1 dL = C AO v L ∫0 L = C AO vL
XA
XA
dX
∫ (− rAA) 0
dX
∫ (− rAA) 0
(5-303)
(5-304)
368
Modeling of Chemical Kinetics and Reactor Design
Therefore,
t≡
V L L •S = = R vL vL • S u
(5-305)
In terms of the fractional conversion XA, the mean residence time t is V t plug flow = R = C AO u
XA
dX
∫ (− rAA) 0
(5-306)
The design equations for plug flow in concentration and fractional conversion are: C
AF V dC A t plug = R = − ∫ =C u (− rA ) AO C AO
XA
dX
∫ (− rAA) 0
(5-307)
Equation 5-307 is the design performance equation for a plug flow reactor at constant density. Figure 5-30 shows the profiles of these equations.
Figure 5-30. Graphical representation of the design equations for a plug flow reactor.
Introduction to Reactor Design Fundamentals for Ideal Systems
369
The area of 1/(–rA) versus CA or XA plots is determined for all design equations for batch, CFSTR, and plug flow reactors by employing the Simpson’s rule. For zero-order homogeneous reaction V t plug = R = C AO u
XA
dX
∫ (− rAA) 0
where
(− rA ) = kC 0AO = k VR C AO = • XA u k
or
k
VR = kt plug = C AO X A u
For first order irreversible reaction at constant density A → products, (–rA) = kCA, the plug flow design equation is C
t plug =
AF VR dC A =− ∫ u (− rA ) C AO
=−
C AF
∫
C AO
t plug =
dC A kC A
VR 1 C AO = ln u k C AF
In terms of the fractional conversion XA t plug =
VR = C AO u
XA
dX
∫ (− rAA) 0
370
Modeling of Chemical Kinetics and Reactor Design
where
(− rA ) = kC A = kC AO (1 − X A ) C V t plug = R = AO u k C AO t plug =
XA
dX
∫ (1 − XAA ) 0
VR 1 = − ln (1 − X A ) u k
(5-308)
When the volume of the reaction mixture changes proportionately with conversion,
V = VO (1 + ε A X A ) and
CA 1 − XA = C AO 1 + ε A X A
For first order reaction:
(− rA ) = kC A = kC AO
(1 − X A )
(5-309)
(1 + ε A X A )
Substituting Equation 5-309 into Equation 5-307 gives
t plug = C AO
X AF
∫ 0
=
1 k
X AF
∫ 0
dX A kC AO (1 − X A ) (1 + ε A X A )
1 dX + (1 − X A ) A
X AF
ε X
∫ (1 −A XAA ) dX A 0
Integration of Equation 5-310 yields
(5-310)
Introduction to Reactor Design Fundamentals for Ideal Systems
t plug =
{
1 − ε A X AF − ln (1 − X AF ) [1 + ε A k
]}
371
(5-311)
k1
First order reversible reaction A [ rR where CRO /CAO = θR, at any conk stant εA and (–rA) = k1CA – k2CR,2 and at equilibrium conversion XAe, the design equation is: X Ae − X A θ + rX Ae k1t plug = R −(1 + ε A X Ae ) ln − εAXA θ R + r X Ae
(5-312)
For second order irreversible reaction with equimolar feed A + B → products or 2A → products at any constant εA, the design equation is C AO kt plug = 2 ε A (1 + ε A ) ln(1 − X A ) + ε 2A X A + (ε A + 1)
2
XA (5-313) (1 − X A )
The design equations for both batch and plug flow systems show that at constant density, εA = 0, t plug and t batch are identical, and either of these equations can be used interchangeably. Where systems change in density, there is no direct relationship between the batch and plug flow equations. In such cases, the correct equation must be applied for the particular problem.
HETEROGENEOUS TUBULAR REACTOR If the reaction in a tubular reactor proceeds in a solid catalyst (e.g., in the form of a packed bed of catalyst pellets), the conversion rate is often given per unit mass of solids ( − rA′ ) . In this case, the total mass of solids ML required for a certain degree of conversion is ML = um
XA
∫ 0
where Mj ( − rA′ ) um ML
= = = =
dX A M j ( − rA′ )
(5-314)
molar mass of species, kg/kmol molar rate of conversion per unit mass of the solid kmol/kg • s mass flowrate, kg/s mass of solid or catalyst, kg
372
Modeling of Chemical Kinetics and Reactor Design
The reactor volume is calculated from ML and the bulk density of the catalyst material. ( − rA′ ) depends not only on composition and temperature, but also on the nature and size of the catalyst pellets and the flow velocity of the mixture. In a heterogeneous reaction where a solid catalyst is used, the reactor load is often determined by the term space velocity, SV. This is defined as the volumetric flow at the inlet of the reactor divided by the reaction volume (or the total mass of catalyst), that is SV ≡
um um or ρi VR ρi M L
(5-315)
where ρi is the density at the inlet conditions.
DESIGN EQUATION FOR SYSTEMS OF VARIABLE DENSITY The general design Equation 5-307 was derived with no assumptions made concerning the variation of density. It is valid for constant density and variable density systems. To use the design equation for variable density reacting mixtures, the rate (–r) must be expressed as a function of the fractional conversion X that properly accounts for the changes in volume as the reaction proceeds. An approximate relation for V(X) for gases is derived by using the ideal gas law. Moles N is accounted for in a general gas-phase reaction including inerts. Consider the following reaction: aA + bB → rR + sS + (Inerts) At X = 0 NAO
N BO
NRO
NSO
NI
For X > 0 b r s N AO (1 − X A ) N BO − N AO X A N RO + N AO X A N SO + N AO X A N I a a a
Then the total mole for X > 0 is
Introduction to Reactor Design Fundamentals for Ideal Systems
373
b r N T = N AO − N AO X A + N BO − N AO X A + N RO + N AO X A a a s + N SO + N AO X A + ........ + N I a
(5-316)
or NT = NO +
r + s + ....... − a − b − .... N X AO A a
(5-317)
where NO = total initial mole
= N AO + N BO + .......... + N RO + N SO + ........N I
(5-318)
Substituting Equation 5-317 into the ideal gas law gives the total volume V: V= =
N T RT P N O RT r + s + .... − a − b − ..... N AO RT X A + P a P
(5-319)
or V = VO +
r + s + ....... − a − b − V X AO A a
(5-320)
Assuming that the total pressure is constant (i.e., when the pressure drop in the reactor is neglected), Equation 5-320 becomes V = VO (1 + ε A X A )
(5-18)
where Levenspiel refers to ε A as the “expansion factor.” This is identical to the change in the total volume per unit change in conversion as a fraction of the initial volume, VO at X = 0.
374
Modeling of Chemical Kinetics and Reactor Design
Comparing Equations 5-320 and 5-18 r + s + ....... − a − b VAO εA = VO a
(5-320a)
However, in practice, εA is much more easily calculated for a given reaction by directly using Equation 5-18 εA =
V − VO VO X A
(5-20)
The expansion factor εA can be determined if V is known at some nonzero value of X. The most likely condition at which V can be determined is at total conversion, where the volume is readily computed from the stoichiometry. Then
εA =
Vl − VO VO
where Vl is the total volume at X = 1. Consider the reaction 2 NH 3
[
3H 2 + N 2 for a feed of pure ammonia.
V at X = 0 2VA
0
0
(VO = 2VA)
3VA
VA
(V1 = 4VA)
V at X = 1 0 and εA =
4 VA − 2 VA =1 2 VA
The same reaction with a feed of 25% NH3 and 75% inerts yields 2NH3 [ 3H2 + N2 + (Inerts) V at X = 0 2Va
0
0
6VA
(VO = 8VA)
3VA
VA
6VA
(V1 = 10VA)
V at X = 1 0
Introduction to Reactor Design Fundamentals for Ideal Systems
375
and
εA =
10 VA − 8VA = 0.25 8VA
These calculations show that the volume dependency of a gas-phase reaction is a function not only of the stoichiometry, but also of the inerts content of the reacting mixture. The sensitivity of volume to conversion is lowered as the inerts increase. The expansion factor, εA, is positive for reactions producing a net increase in moles, negative for a decrease in moles, and εA = 0 for reactions producing no net changes and at constant volume.
DESIGN EQUATIONS FOR HETEROGENEOUS REACTIONS Heterogeneous reactions involve two or more phases. Examples are gas-liquid reactions, solid catalyst-gas phase reactions and products, and reactions between two immiscible liquids. Catalytic reactions as illustrated in Chapter 1 involve a component or species that participates in various elementary reaction steps, but does not appear in the overall reaction. In heterogeneous systems, mass is transferred across the phase. There are several ways of defining the rate for heterogeneous systems. In solid catalyzed gaseous reactions, the rate can be defined in several ways: • • • • •
A A A A A
catalyst volume basis void volume (gas volume) basis catalyst mass basis catalyst surface area basis reactor volume basis
These rates are related to the material balance by considering steady state plug flow systems. The differential material balance on component A in a heterogeneous reaction is FAO dX A = ( − rA ) dV = ( − rA′ ) dW = ( − rA′′ ) dS = ( − rA′′′) dVp = ( − rAiv ) dVr
(5-321)
376
Modeling of Chemical Kinetics and Reactor Design
where FAO = inlet molar flowrate of A feed (mol/s) (uOCAO) CAO = initial molar concentration of the key component A at feed (mol/m3) uO = volumetric flowrate of feed (m3/sec) XA = fractional conversion of A V = void volume or gas phase volume, m3 W = mass of catalyst, kg S = catalyst surface area, m2 Vp = volume of catalytic solid (pellet volume), m3 Vr = reactor volume, m3 (–rA) = rate of disappearance of A based on volume of fluid, mol/m 3 • sec ( − rA′ ) = rate of disappearance of A based on unit mass of catalyst, mol/kg • sec ( − rA′′ ) = rate of disappearance of A based on unit surface, mol/ m2 • sec ( − r ′′′ ) = rate of disappearance of A based on unit volume of solid, mol/m3 • sec ( −rAiv ) = rate of disappearance of A based on unit volume of reactor, mol/m3 • sec For constant volume systems, Equation 5-321 becomes XA
V t = = FAO C AO =
∫ 0
V Vp
dX A V = (− rA ) W XA
∫ 0
XA
∫ 0
dX A V = (− rA′′′) Vr
dX A V = (− rA′ ) S XA
dX
∫ (− rAivA) 0
XA
dX
∫ (− rA′′A) 0 (5-322)
The experimental study of solid catalyzed gaseous reactions can be performed in batch, continuous flow stirred tank, or tubular flow reactors. This involves a stirred tank reactor with a recycle system flowing through a catalyzed bed (Figure 5-31). For integral analysis, a rate equation is selected for testing and the batch reactor performance equation is integrated. An example is the rate on a catalyst mass basis in Equation 5-322. tW = C AO V
XA
dX
∫ (− rA′ ) 0
(5-323)
Introduction to Reactor Design Fundamentals for Ideal Systems
377
Figure 5-31. Recycle reactor for catalyst evaluation.
For each experiment, the left and right sides of Equation 5-323 are determined. The values of both sides are plotted and tested for linearity. There are two types of continuous flow stirred tank catalytic reactors. One has the catalyst in a spinning basket, while the movement of the basket provides gas-catalyst contact, coupled with gaseous mixing. The other has a fixed catalyst bed and the gas is circulated at high rates through the packed catalyst. Most of the gas exiting from the catalyst bed is recycled back through it, and the net throughput is small. The high flowrates ensure good heat transfer to the catalyst and eliminate gas phase resistance to mass transfer. The high level of recirculation results in low conversion per pass, and the system can be analyzed as if it were a perfect mixer. The specific rate is determined as:
(− rA′ ) =
FAO X A W
(5-324)
378
Modeling of Chemical Kinetics and Reactor Design
Each experimental run gives the reaction rate at the composition of the exit fluid. Tubular reactors can be operated as differential reactors (i.e., at high throughputs and low conversions) or as integral reactors (i.e., at low throughputs and high conversions). Differential reactors give the rate as:
(− rA′ ) =
FAO ∆X A ∆W
(5-325)
After the rates have been determined at a series of reactant concentrations, the differential method of testing rate equations is applied. Smith [3] and Carberry [4] have adequately reviewed the designs of heterogeneous catalytic reactors. The following examples review design problems in a plug flow reactor with a homogeneous phase.
Example 5-14
The decomposition of phosphine in the gas phase 4PH3(g) → P4(g) + 6H2 at 650°C is first order. The specific rate is given by log k = −
18, 963 + 2 log T + 12.3 T
(sec −1 )
Determine what size plug flow reactor, operating at 650°C and 5.0 atm, produces 85% conversion of the feed consisting of 4 kg/mols of pure phosphine per hour. Solution The rate constant k at 650°C (923 K) is
log10 k = −
18, 963 + 2 log10 (923) + 12.3 923
k ≈ 0.0033 sec −1 (12.0 hr −1
)
Consider the reaction 4PH3(g) → P4(g) + 6H2 or 4A → C + 6D, where A = PH3, C = P4, and D = H2. Because the reaction is first order, then
Introduction to Reactor Design Fundamentals for Ideal Systems
379
(− rA ) = kC A kg • mol = 12C A 3 m • hr The volume of plug flow reactor in Equation 5-307 is given by
VR = uC AO
= uC AO
X AF
dX
∫ (− rAA) 0
X AF = 0.85
∫ 0
dX A kC A
At constant pressure of 5.0 atm, the concentration CA is 1 − XA C A = C AO 1 + εAXA Therefore, the volume of the plug flow reactor is 0.85
VR = uC AO
∫ 0
dX A 1 − XA kC AO 1 + εAXA
Integration of the above equation yields Equation 5-311, which is
VR =
{
} 00..850
u − ε A X A − ln(1 − X A )[1 + ε A ] k
where u εA XA FAO
= = = =
volumetric flowrate m3/hr (7 – 4)/4 = 0.75 0.85 4[(kg • mol)/hr] = uCAO
Assuming an ideal gas
380
Modeling of Chemical Kinetics and Reactor Design
pV = nRT kg • mol m3
p n = C A = AO V RT
l • atm Gas constant R = 0.08206 gmol • K pAO = 5.0 atm T = 923 K
C AO =
5.0
(0.08206)(923)
= 0.066
u= =
atm 3 m • atm • K kg mol • K
kg • mol m3
FAO C AO 4.0 0.066
kg • mol m3 × kg • mol hr
m3 = 60.59 hr
VR =
m3 60.59 −(0.75 × 0.85) − ln (1.0 − 0.85)(1 + 0.85)} hr { 12.0 hr
VR =14.5 m 3
Introduction to Reactor Design Fundamentals for Ideal Systems
381
Example 5-15
Consider an aqueous feed of A and B (600 l/min, 150 mmol of A/l, 300 mmol of B/l) that is being converted to product in a plug flow reactor. The stoichiometry and rate equation are:
A + B→ C
(− rA ) = 300C A C B
mol l • min
Find the volume of the reactor needed for 95% conversion of A to product. Solution Assuming that the reaction is second order, the design Equation 5-307 for a plug flow reactor is C
t plug =
AF VR dC A =− ∫ =C u (− rA ) AO C AO
XA
dX
∫ (− rAA) 0
From the stoichiometry CB = CBO – (CAO – CA), the conversion of XA is (CAO – CA)/CAO. Therefore, CA = CAO(1 – XA) and CAO – CA = CAOXA. The rate expression for the second order is
(− rA ) = kC A C B
mol l • min
l k = 300 mol • min
The design equation in terms of the fractional conversion XA becomes VR = C AO u = C AO
X AF = 0.95
∫ 0
X AF = 0.95
∫ 0
dX A kC A C B
dX A kC AO (1 − X A )(C BO − C AO X A )
382
Modeling of Chemical Kinetics and Reactor Design
where CBO/CAO = θB
VR = C AO u
0.95
∫
kC 2AO 0
dX A (1 − X A )(θB − X A )
Integration of the above equation involving partial fractions and further manipulation yields θ − X A u VR = ln B kC AO (θ B − 1) 1 − X A u = 600
l min
k = 300
l mol • min
VR =
C AO = 150
mmol l
θB =
X AF = 0.95 XA =0
C BO = 300
mmol l
C BO = 2.0 C AO
2 − 0.95 2 − 0 600 ln − ln −3 300 × 150 × 10 (2 − 1) 1 − 0.95 1− 0
VR = 31.34 l Example 5-16
Hougen and Watson in an analysis of Kassel’s data for the homogeneous, vapor-phase dehydrogenation of benzene in a tubular-flow reactor considered two reactions: 1. 2C6H6(g) → C12H10(g) + H2(g) 2. C6H6(g) + C12H10(g) → C18H14(g) + H2(g) The rate equations are: r1 = 14.94 × 10 6 e
−15, 200 T
2 pD pH pB − K1
lb moles benzene reacted hr • ft 3
Introduction to Reactor Design Fundamentals for Ideal Systems
r2 = 8.67 × 10 6 e
−15, 200 T
383
pT pH pBpD − K2
lb moles triphenyl produced or diphenyl reacted hr • ft 3 where pB pD pT pH K 1, K 2
= = = = =
partial pressure of benzene, atm partial pressure of diphenyl, atm partial pressure of triphenyl, atm partial pressure of hydrogen, atm equilibrium constants for the two reactions in terms of partial pressures
The data on which the rate equations are based were obtained at a total pressure of 1 atm and temperatures of 1,265°F and 1,400°F in a 0.5-in. tube, 3 ft long. To design a tubular reactor that will operate at 1 atm pressure and 1,400°F: 1. Determine the total conversion of benzene to di- and triphenyl as a function of space velocity. 2. Determine the reactor volume required to process 10,000 lb/hr of benzene (the feed is pure benzene) as a function of the total conversion. 3. Determine the space velocity for the maximum concentration of diphenyl. Assume that the reaction is operated isothermally and that no other reactions are significant.3 Solution Since the reactor is isothermal, the equilibrium constants K1 and K2 are estimated at 1,400°F from equations developed by Hougen and Watson. The results are: K1 = 0.312 K2 = 0.480 3
Source: J. M. Smith, Chemical Engineering Kinetics, 3rd ed. McGraw-Hill, 1981.
384
Modeling of Chemical Kinetics and Reactor Design
At 1,400°F (1,033 K) the two rates in terms of the disappearance rate of benzene are p •p r1 = (14.96 × 10 6 ) e −14.7 p 2B − D H 0.312 p •p = 6.23 p 2B − D H 0.312
(5-326)
p •p r2 = (8.67 × 10 6 ) e −14.7 p B • p D − T H 0.480 p •p = 3.61 p B • p D − T H 0.480
(5-327)
The design equation for a plug flow is
V = FA
X A = X AF
∫
XA =0
dX A (− rA )
If the mass balances are based on benzene, then the two equations are
dX V =∫ 1 F r1
(5-328)
dX 2 V =∫ F r2
(5-329)
where the conversion X1 is the pound moles of benzene disappearing by reaction 1 per pound mole of the feed, and the conversion X2 is the pound moles of benzene disappearing by reaction 2 per pound mole of the feed. Based on 1.0 mole of entering benzene, the moles of each component at conversions X1 and X2 are
Introduction to Reactor Design Fundamentals for Ideal Systems
Component Hydrogen (H2) Diphenyl (C12H10) Benzene (C6H6) Triphenyl (C18H14) Total moles
385
Mole at conversions X1 and X2 (1/2)X1 + X 2 (1/2)X1 – X2 1 – X1 – X2 X2 1.0
Since the total mole equals 1.0, the mole fractions of each component are also given by these quantities. If the components are assumed to behave as ideal gases, then the partial pressures are: Component Hydrogen (H2), PH Diphenyl (C12H10), PD Benzene (C6H6), pB Triphenyl (C18H14), pT
Partial pressure pi 1.0[(1/2)X 1 + X2] = (1/2)X1 + X2 (1/2)X1 – X2 1 – X1 – X2 X2
Substituting the partial pressures of the components in Equations 5-326 and 5-327 gives
1 X − X 1 X + X 1 2 1 2 2 2 2 r1 = 6.23(1 − X1 − X 2 ) − 0.312
(5-330)
1 X 2 X1 + X 2 2 1 r2 = 3.61(1 − X1 − X 2 ) X1 − X 2 − 2 0.480
(5-331)
Substituting Equations 5-330 and 5-331 in the design Equations 5-328 and 5-329, values of exit conversions X1, X2, and the composition of the components are computed for various values of V/F. The computer program PLUG51 employing the Runge-Kutta fourth order numerical method was used to determine the conversions and the compositions of the components. Applying the Runge-Kutta method, Equations 5-328 and 5-329 in differential forms are
386
Modeling of Chemical Kinetics and Reactor Design
dX1 = r1 ( X1 , X 2 ) d( V F ) 1 X − X 1 X + X 1 2 1 2 2 2 2 = 6.23(1 − X1 − X 2 ) − 0.312
(5-332)
dX 2 = r2 ( X1 , X 2 ) d( V F ) 1 X 2 X1 + X 2 1 2 = 3.61(1 − X1 − X 2 ) X1 − X 2 − 2 . 0 480
(5-333)
Writing Equations 5-332 and 5-333 as function programs to determine V/F, X1 (the conversion of benzene in reaction 1), X2 (the conversion of benzene in reaction 2), XT (the total conversion of X1 and X2). The procedure calculates X1 and X2 for the first increment of ∆(V/F), beginning at the entrance to the reactor. The rates at the entrance are given by Equations 5-330 and 5-331 with X1 = X2 = 0. Choose an increment of ∆(V/F) = 0.005 ft/(lb • mol feed – hr) to begin the calculation.
Y = 1.0 − X(1) − X(2) Z = 0.5 * X(1) − X(2) W = 0.5 * X(1) + X(2)
Z * W F(1) = 6.23 * Y **2 − 0.312
X( 2 ) * W F(2) = 3.61* (Y * Z ) − 0.480 XT = XEND(1) + XEND(2)
(5-334)
Introduction to Reactor Design Fundamentals for Ideal Systems
387
The computer program PLUG51 used Equation 5-334 to determine the conversions and the compositions of the components. Table 5-13 illustrates the results of the computer program, and Figure 5-32 shows the plots of the rates of each reaction as a function of V/F. In both instances, the rates decrease toward zero as V/F increases. Figure 5-33 shows the plot of the total conversion XT versus V/F. The reactor volume required to process 10,000 lb/hr of benzene is estimated from Table 5-13. For a total conversion of 50.8%, V/F = 0.2 V = 0.2 F = 0.2 ×
10, 000 lb ft 3 • hr lb mol • • 78 hr lb mol lb
= 25.64 ft 3 The computer results from Table 5-13 show the calculated compositions of benzene, diphenyl, triphenyl, and hydrogen. At a fixed feedrate, increasing V/F values correspond to movement through the plug flow reactor (i.e., increasing reactor volume). Thus, these results illustrate how the composition varies with position in the reactor. Here, the mole fraction of benzene decreases steadily as the reaction mixture progresses in the reactor, while the composition of diphenyl increases and reaches a maximum between 1,684 and 1,723 hr–1 and thereafter decreases. This is often typical of an intermediate in consecutive reactions. Details of the Runge-Kutta fourth order numerical method and other improved methods are illustrated in Appendix D.
COMPARISON OF IDEAL REACTORS By comparing the design equations of batch, CFSTR, and plug flow reactors, it is possible to establish their performances. Consider a single stage CFSTR. (text continued on page 390)
388
Modeling of Chemical Kinetics and Reactor Design
Table 5-13 Conversion versus V/F for the dehydrogenation of benzene using the Runge-Kutta fourth order method
Introduction to Reactor Design Fundamentals for Ideal Systems
Rates of reaction (lb mol/ft3 • hr)
Table 5-13 (continued)
V/F (ft3)(hr)/lb mol
Figure 5-32. Rates of reactions for dehydrogenation of benzene.
389
Modeling of Chemical Kinetics and Reactor Design
Total conversion of benzene XT = X1 + X2
390
V/F (ft3)(hr)/lb mol
Figure 5-33. Plot of total conversion versus V/F (ft3)(hr)/lb mol.
(text continued from page 387)
CFSTR with inflow of component A
Introduction to Reactor Design Fundamentals for Ideal Systems
391
At constant density, the material balance is uCAO = uCA + (–rA)Vr and the volume of the reactor is C − C AF VR CFSTR = u AO ( − rA )
For a well-mixed batch reactor, the design equation is −
1 VR batch
•
dN A = ( − rA ) dt
For constant density (i.e., ρ is constant), CA =
NA VR batch
and dC A =
1 VR batch
• dN A
The above equation becomes
−
dC A = ( − rA ) dt
Integrating the equation between the limits at t = 0, CA = CAO and t = t, CA = CAF gives
−
C AF
∫
C AO
t
dC A = dt = t batch (− rA ) ∫0
Time must be included for emptying, cleaning, and filling the batch reactor (≈30 min).
392
Modeling of Chemical Kinetics and Reactor Design
Consider a plug flow reactor:
where the design equation is
−
C AF
dC
∫ (− rAA) = C AO
VR plug flow u
= t plug flow
Assuming a first order reaction A → Products, the rate expression is (–rA) = kCA where CAO = 10 kg mol/m3 and CAF = 1.0 kg mol/m3. The volumetric flowrate of the mixture is 1.0 m 3/hr and the rate constant is k = 1.0 hr–1. Therefore, the volume of the reactor for a single stage CFSTR is
VR = =
u(C AO − C AF ) (− rA ) = k1C AF 1.0 (10 − 1.0) = 9 m3 1.0 × 1.0
For a batch reactor, the time of the batch is
−
C AF
dC
∫ (− rAA) = t batch C AO
Introduction to Reactor Design Fundamentals for Ideal Systems
393
For the first order reaction, the design equation is
−
C AF
∫
C AO
t= =
dC A = t batch or plug flow k1C A
C 1 ln AO k1 C AF 1 10 ln 1.0 1
= 2.303 hr
t plug flow =
VR plug flow u
Therefore, the volume of the plug flow reactor is
VR = u t = 1.0 × 2.303 = 2.303 m 3 t batch = 2.303 hr
Time added for emptying, cleaning, and filling the batch is 30 min. The total batch processing time is 2.303 + 0.5 = 2.803 hr. Therefore, the volume of batch is VR,batch = 2.803 m3. The following considers the volume of the CFSTR and plug flow reactors at varying conversion levels of 10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, 90%, and 95% for a first order reaction. At 10% conversion XA = 0.1,
XA =
C AO − C AF = 0.1 C AO
394
Modeling of Chemical Kinetics and Reactor Design
C AO − C AF = 0.1 C AO
C AF = C AO (1.0 − 0.1) = 0.9 C AO where CAO = 10 kg mol/m3 and CAF = 9.0 kg mol/m3 and
VR =
u(C AO − C AF ) k1C AF
=
1.0 (10.0 − 9.0) 1× 9
= 0.111 m 3 For the plug flow reactor, the design equation at 10% conversion XA = 0.1 is t=
C VR 1 = ln AO u k1 C AF
VR, plug flow = =
C u ln AO k1 C AF 1.0 10 ln 1.0 9
= 0.105 m 3
The Microsoft Excel spreadsheet program REACTOR.xls was used to compute the volumes of the CFSTR, plug flow reactors, and the ratio of the volumes for fractional conversions of 20%, 30%, 40%, 50%, 60%, 70%, 80%, 90%, and 95% for a first order reaction. Table 5-14 shows the volumes of the CFSTR, plug flow reactors, and the ratio of the volumes at given conversion levels.
Introduction to Reactor Design Fundamentals for Ideal Systems
395
Table 5-14 Volume of CFSTR and plug flow reactors with respect to conversion level for a first order reaction Conversion XA, %
10
Volume of CFSTR, m
3
20
30
40
50
0.111
0.25
0.429
0.667
1.0
Volume of plug flow, m3
0.105
0.223
0.357
0.511
0.693
VR, CFST Ratio of V R , plug flow
1.057
1.121
1.202
1.305
1.443
60
70
80
90
95
Conversion XA, % Volume of CFSTR, m
3
1.5
2.33
4.0
9.0
19.0
Volume of plug flow, m3
0.916
1.204
1.609
2.303
2.996
VR, CFST Ratio of V R , plug flow
1.638
1.935
2.486
3.908
6.342
Table 5-14 shows that there is no significant difference between the volume of the CFSTR and plug flow reactors at low conversions. However, at 70% and higher, more than twice as much volume is required for the CFSTR. Additionally, the ratio of the volume increases with level of conversions and reaction order. Figure 5-34 illustrates the ratio of the volumes of CFSTR and plug flow reactors with conversion. 1/(–rA) VERSUS CA PLOT If 1/(–rA) versus CA is the plot for the limiting component A in a CFSTR and plug flow system, the mean residence time t CFSTR is expressed as t CFSTR =
C AO − C A 1 • (C − C ) = (− rA ) (− rA ) AO A
For a plug flow reactor, the mean residence time t plug is
t plug = −
CA
dC
∫ (− rAA) C AO
396
Modeling of Chemical Kinetics and Reactor Design
Figure 5-34. Plot of the ratio of volumes of CFSTR and plug flow reactors versus conversion for a first order reaction.
The residence time for the CFSTR is the area under the rectangle of width (CAO – CA) and height 1/(–rA). The residence time t plug is the area under the curve 1/(–rA) from CAO to CA. Figure 5-35 shows that 1/(–rA) is a monotonically increasing function of (CAO – CA) if the order of reaction, n > 0, and a horizontal line if n = 0 and decreases with (CAO – CA) if n < 0. In Figure 5-36, the area of the CFSTR is larger while 1/(–rA) is a monotonically increasing function of (CAO – CA) for n > 1. Both areas are equal for n = 0, and the rectangle has a smaller area for n < 0. At high conversions, the CFSTR requires a larger volume, and as CA → 0, the 1/(–rA) versus CAO – CA curve rapidly increases to ∞. In the case where t CFSTR becomes very large relative to t plug , the isothermal plug flow reactor is much preferred to the single-stage CFSTR at high conversions when n > 0.
CFSTR AND PLUG FLOW SYSTEMS Consider a combination of CFSTR and plug flow systems as shown below for a first order irreversible reaction.
Introduction to Reactor Design Fundamentals for Ideal Systems
397
Figure 5-35. Plot of 1/(–r A) versus (CAO – C A) for the nth order irreversible reactions.
Figure 5-36. Residence time in CFSTR and plug flow reactors from 1/(–rA) versus CAO – CA plot.
398
Modeling of Chemical Kinetics and Reactor Design
TUBULAR (PLUG FLOW) CFSTR
CFSTR The material balance of component A is uCAO = uCA1 + kCA1V1 or C A1 =
C AO 1 + kt1
where t1 = V1 u . Plug Flow Reactor The concentration leaving the CFSTR, CA1, is the inlet concentration to the plug flow reactor. The material balance on component A is C
t plug = t 2 =
A2 V2 dC A =− ∫ u kC A C A1
The residence time t 2 in the plug flow is t2 = −
1 CA2 ln k C A1
or C A 2 = C A1e − kt 2 C = AO e − kt 2 1 + kt1
Introduction to Reactor Design Fundamentals for Ideal Systems
399
Consider reversing the reactors as shown below
CFSTR
Plug Flow Reactor C
t1 =
A1 V1 dC A =− ∫ u kC A C AO
C − kt1 = ln A1 C AO or C A1 = C AO e − kt1
CFSTR uC A1 = uC A 2 + kC A 2 V2
or CA2 =
C A1 C AO − kt1 = e 1 + kt 2 1 + kt 2
When t1 = t 2 , that is, the volumes of CFSTR and plug flow are the same, then for the first order irreversible reaction, the expressions are identical for both combinations.
400
Modeling of Chemical Kinetics and Reactor Design
When the reactors are of equal volume, the overall conversion is independent regardless of which reactor precedes. However, generally, the CFSTR should precede the plug flow to minimize the total reactor volume. Figure 5-37 shows the total residence time of the CFSTR and plug flow reactors in series.
DYNAMIC BEHAVIOR OF IDEAL SYSTEMS The review of the performance equations for the ideal system has been for the steady state situation. This occurs when the process has begun and all transient conditions have died out (that is, no parameters vary with time). In all flow reactors, parameters such as the flowrate, temperature, and feed composition can vary with time at the beginning of the process. It is important for designers to review this situation with respect to fluctuating conditions and the overall control and
Figure 5-37. Residence time from 1/(–rA) versus CAO – CA plot for plug flow reactors and CFSTRs in series.
Introduction to Reactor Design Fundamentals for Ideal Systems
401
integrity of the plant. Many industrial accidents and explosions occur during startup and shut-down, and by improperly charging the feed to the reactor. The following considers the unsteady state of a CFSTR:
Consider a CFSTR at constant density. If the flowrate and the reactor volume are constant, the material balance, Equation 5-1, on component A yields
uC AO = uC A + ( − rA )VR + VR where VR
dC A dt
(5-335)
dC A = accumulation in the reactor. dt
Rearranging Equation 5-335 gives
dC A 1 1 + + k C A = C AO dt t t where t = VR/u = the mean residence time.
(5-336)
402
Modeling of Chemical Kinetics and Reactor Design
Equation 5-336 is a first order differential equation. The behavior of component A can be predicted with time from the boundary conditions, the flowrate of the feed, composition, and the volume of the reactor. Equation 5-336 is of the form dy/dx + Py = Q where the integrating factor I.F. = e∫Pdx. e∫
Pdx
dy Pdx Pdx + e ∫ Py = Q • e ∫ dx
d ∫ Pdx Pdx • y = Q • e∫ e dx The formal general solution is e∫Pdx • y = ∫e∫Pdx • Qdx + Const. In Equation 5-336, the I.F. is
I.F. = e
1 + kt dt t
∫
=e
1 + kt t t
Multiplying the I.F. factor by both the left and right sides of Equation 5-336 gives
e
1 + kt t t
1 + kt t
dC A + e dt
1 + kt t
1 1 + kt • C A = • C AO • e t t
or 1 + kt 1 + kt t d t 1 • C A = • C AO e t e t dt
Integrating Equation 5-337 yields
e
1 + kt t t
C • C A = AO t
∫e
A general solution is
1 + kt t t
• dt + Const.
(5-337)
Introduction to Reactor Design Fundamentals for Ideal Systems 1 + kt t t
− C C A ( t ) = AO + Const. e (1 + kt )
403
(5-338)
At the boundary condition t = 0, CA(t) = CA init and the Const. = CAinit – CAO/(1 + k t ), which gives 1 + kt t t
C C − C A ( t ) = AO + C A init − AO e 1 + kt 1 + kt or
C A (t ) =
{
}
C AO + C A init (1 + kt ) − C AO e 1 + kt
1 + kt − t t
(5-339)
Figure 5-38 shows plots of the dynamic response to changes in the inlet concentration of component A. The figure represents possible responses to an abrupt change in inlet concentration of an isothermal CFSTR with first order irreversible reaction. The first plot illustrates the situation where the reactor initially contains reactant at C A init and at t = 0. The reactant flow at CAO begins until component A reaches a steady state condition. The second plot starts with C A init in the reactor at t = 0. Tables 5-15, 5-16, and 5-17, respectively, show common equations for all reactor models involving a first order reversible reaction. Example 5-17
Acetic anhydride is hydrolyzed at 40°C in a CFSTR. The reactor is initially charged with 0.57 m3 of an aqueous solution containing 0.487 kmol/m3 of anhydride. The reactor is heated quickly to 350 K, and at that time, a feed solution containing 0.985 kmol/m3 of anhydride is run into the reactor at the rate of 9.55 × 10–4 m3/sec. At the instant the feed stream is introduced, the product pump is started and the product is withdrawn at 9.55 × 10–4 m3/sec. The reaction is first order with a rate constant of 6.35 × 103 sec–1.
404
Modeling of Chemical Kinetics and Reactor Design
Figure 5-38. Dynamic response in a CFSTR system.
1. Perform the unsteady state balance and solve to obtain the startup transient in the product stream concentrations of anhydride and acid. 2. Determine the concentrations of anhydride and acid after 120 sec. Solution The reaction involving acetic anhydride and water in the hydrolysis is
Introduction to Reactor Design Fundamentals for Ideal Systems
405
Table 5-15 Reversible Reaction A B R Total Concentration
Ct = C A + C R
Arrhenius Law
k = A exp(EA/RT)
van’t Hoff Equation
− ∆H R 1 1 K CT2 = K CT1 exp − R T1 T2
Equilibrium Constant
KC =
Conversion
X A =1−
Rate Law
−
k C Re C Ai + C Ri − C Ae = = k ′ C Ae C Ae CA C Ai
dC A C = k C A − R dt KC
Source: J. D. Seader, Computer Modeling of Chemical Processes, AIChE Monograph Series, 15, Vol. 81. Reproduced with permission of the American Institute of Chemical Engineers, Copyright © 1985 AIChE. All rights reserved.
k CH 3CO • O • CO • CH 3 + H 2 O → 2CH 3COOH
Acetic anhydride
Water
Acetic acid
k → 2C . Assuming that the reaction is first order with or A + B respect to the anhydride, component A, (–rA) = kCA.
The unsteady state balance of acetic anhydride in a CFSTR. (text continued on page 408)
406
Modeling of Chemical Kinetics and Reactor Design
Table 5-16 Steady-state reactor models for A
[R
Source: J. D. Seader, Computer Modeling of Chemical Processes, Monograph Series 15 Vol. 18. Reproduced with permission of the American Institute of Chemical Engineers. Copyright © 1985, AIChe. All rights reserved.
Introduction to Reactor Design Fundamentals for Ideal Systems
Table 5-17 Dynamic reactor models for A
407
[R
Source: J. D. Seader, Computer Modeling of Chemical Processes, Monograph Series 15 Vol. 18. Reproduced with permission of the American Institute of Chemical Engineers. Copyright © 1985, AIChe. All rights reserved.
408
Modeling of Chemical Kinetics and Reactor Design
(text continued from page 405)
The
unsteady state material balance of component A is
uC AO = uC A + ( − rA )VR + VR
dC A dt
(5-335)
Rearranging Equation 5-335 gives dC A 1 1 + + k C A = C AO dt t t
(5-336)
dC A 1 = (C AO − C A ) − kC A dt t
(5-340)
or
Both Equations 5-336 and 5-340 are first order differential equations, which can be solved to determine the transient concentration of the anhydride. The transient concentration of acetic anhydride from Equation 5-336 with a first order irreversible reaction is obtained from Equation 5-338
C A (t ) =
{
}
C AO + C A init (1 + kt ) − C AO e
where CAO CAinit t = VR/u VR u k CAO CAinit VR u k
= = = = = = = = = = =
1 + kt
1 + kt − t t
feed concentration, kmol/m3 initial concentration at time t = 0, kmol/m3 mean residence time, sec volume of the reactor, m3 volumetric flowrate, m3/sec rate constant, sec–1 0.985 kmol/m3 0.485 kmol/m3 0.55 m3 9.55 × 10–4 m3/sec 6.35 × 103 sec–1
(5-341)
Introduction to Reactor Design Fundamentals for Ideal Systems
t=
409
VR 0.55 = = 575.916 sec u 9.55 × 10 −4
1 + kt = 1 + 6.35 × 10 −3 × 575.916 = 4.657
C A (t ) =
4.657
0.985 0.485 × 4.657 − 0.985 − 575.916 t + e 4.657 4.657
Therefore, the startup anhydride concentration is C A ( t ) = 0.212 + 0.273 e −0.008t kmol m 3
(5-342)
with time t in sec. The material balance for the acetic acid is
(+ rC )VR = uCC + VR
dC C dt
(5-343)
or
0 = uC C − kC A VR + VR
dC C dt
(5-344)
Rearranging Equation 5-344 gives dC C 1 + C C = kC A dt t
(5-345)
where Equation 5-345 is a first order differential equation. The integrating factor is 1
t
Pdx ∫ dt I.F. = e ∫ = e t = e t
Multiplying both sides of Equation 5-345 by the I.F. gives t
et
t
t
dC C 1 + e t • • C C = kC A e t dt t
410
Modeling of Chemical Kinetics and Reactor Design
or t t d t t = • e C kC e C A dt
(5-346)
Integrating Equation 5-346 yields t
t
e t • C C = kC A ∫ e t dt + Const. t
t
e t • C C = ktC A e t + Const.
(5-347)
(5-348)
The boundary condition at t = 0, CC = 0 and Const. = − ktC A . Equation 5-348 becomes C C = ktC A − ktC A e
−t t
(5-349)
Substituting Equation 5-342 into Equation 5-349 gives the transient composition of acetic acid as −t C C = ktC A 1 − e t
(5-350)
which is C C = kt (0.212 + 0.273e −0.008t )(1 − e −0.0017 t ) = (0.775 + 0.998e −0.008t )(1 − e −0.0017 t ) Equations 5-342 and 5-350 are the concentrations of CA and CC after 120 sec.
FLOW RECYCLE REACTOR There are situations where a portion of the product stream in a plug flow reactor is returned to the entrance of the feed stream by means
Introduction to Reactor Design Fundamentals for Ideal Systems
411
of a pump. The pump can be varied to increase the amount of recycle R from zero to a very large value, thus creating some degree of backmixing to the reactor. Consider the plug flow reactor as shown in Figure 5-39. Component A is fed to the plug flow reactor at constant density. The volumetric flowrate into the plug flow is u O and the feed concentration of A is CAO. A portion of A exiting from the reactor is fed back through a pump and mixed with the feed stream, referred to as R (i.e., the recycle ratio). The volumetric flowrate at the entrance of the reactor is u = uO(1 + R). A balance at the mixing point M gives uCAi = uOCAO + RuOCAf, which is uO(1 + R)CAi = uOCAO + RuOCAf. The inlet concentration of component A at the entrance of the plug flow reactor is C Ai =
C AO + RC Af 1+R
(5-351)
The residence time in the plug flow is C
t plug =
Af VR VR dC A = =− ∫ u u O (1 + R ) (− rA ) C Ai
or C
Af V dC A t plug = R = − (1 + R ) ∫ uO (− rA ) C Ai
Figure 5-39. The recycle tubular reactor.
412
Modeling of Chemical Kinetics and Reactor Design
For a first order irreversible reaction (–rA) = kCA, which gives Af V dC A (1 + R ) C Ai t plug = R = − (1 + R ) ∫ = ln uO kC A k C Af C
C
(5-352)
Ai
Substituting Equation 5-351 into Equation 5-352 yields
t plug =
VR 1 + R C AO + RC Af ln = uO k C Af (1 + R )
(5-353)
Rearranging Equation 5-353 gives kt plug 1 + R C Af C AO exp = C Af 1 + R (1 + R) C AO
or
C Af = C AO
1 kt (1 + R ) exp plug − R 1 + R
The recycle ratio in terms of the fractional conversion XA for the first order irreversible reaction is
XA =1 −
1 kt (1 + R) exp plug − R R +1
(5-354)
Equation 5-354 determines the value of the recycle ratio for a given conversion, the residence time, and the rate constant in a plug flow reactor. Alternatively, an increase in R will lower the conversion since it produces backmixing in the reactor as it mixes with the feed entrance in the plug flow reactor. As R → ∞, it yields
Introduction to Reactor Design Fundamentals for Ideal Systems
t plug =
413
VR 1 + R C AO + RC Af = ln uO k C Af (1 + R )
which is C + RC Af = ln AO 1 +R C Af (1 + R ) kt plug
or kt plug C AO + RC Af = exp C Af (1 + R ) 1 +R
(5-355)
The expansion of ex is ex =1+ x +
1 2 1 3 x + x +. . . 2! 3!
Expanding Equation 5-355 yields 2 C AO + RC Af kt plug 1 kt plug = 1 + + + . . . C Af (1 + R ) 1 + R 2 1 + R
as R → ∞, it yields kt plug C AO + R = (1 + R ) 1 + C Af 1+ R or
C AO − C Af = kt plug C Af
(5-356)
Equation 5-356 is the familiar CFSTR for a first order reaction. As the recycle of the fluid increases, the reactor becomes completely
414
Modeling of Chemical Kinetics and Reactor Design
backmixed and eventually approaches the performance of a CFSTR. However, the process increases pumping costs and is, therefore, an inefficient method of creating a CFSTR system. The recycle reactor can also act as an efficient mode in creating a small amount of backmixing into a reactor as in the autocatalytic reaction, where the rate is proportional to the product concentration. PRESSURE DROP (∆P) IN PLUG FLOW REACTORS In a homogeneous plug flow reactor, the pressure drop ∆P corresponding to the desired flowrate is small and has little effect on the operating process. However, it is necessary to determine ∆P as part of the design procedure so that ancillary equipment such as pumps may be adequately specified. If high-viscosity liquids (e.g., polymers) or low-pressure gases are used, ∆P will have a major influence on the design. In heterogeneous systems ∆P must be critically reviewed, especially if the reaction involves a two-phase mixture of liquid and gas, or if the gas flows through a deep bed of catalyst particles as in the FCC systems. ∆P should be checked early in the design process to assess its influence on the overall plant integrity. Example 5-18
Consider the application of chemical reactor technology to a commercial reactor.8 Figure 5-40 illustrates a simplified flow diagram of ethylene glycol production. Consider the reactions in the formation of glycol: Hydration of ethylene oxides to ethylene glycol. • Reactions of part of the glycol with ethylene oxide to form diethylene glycol. • Further reaction of the ethylene glycol with ethylene oxide. •
In the following example, ethylene glycol product was manufactured to a specification that limited the diethylene glycol and higher glycol content; formation of these materials caused a loss in yield. Reactions 8
Source: T. E. Corrigan, G. A. Lessells, M. J. D. Dean, Ind. & Eng. Chem. Vol. 60, No. 4, April 1968.
Introduction to Reactor Design Fundamentals for Ideal Systems
415
Figure 5-40. A simplified flow diagram of ethylene glycol.
5-357, 5-358, and 5-359, respectively, were all series-parallel reactions represented by k
(5-357)
k
(5-358)
k
(5-359)
A + B 1 → R 2 A + R →S
A + S 3 → T where A B R S T
= = = = =
ethylene oxide water ethylene glycol di-ethylene glycol tri-ethylene glycol
Considering the above reactions at constant volume (i.e., constant density) in a batch system, rates of disappearance for A, B, R, and S are:
416
Modeling of Chemical Kinetics and Reactor Design
(− rA )net = −
dC A = k1C A C B + k 2 C A C R + k 3C A C S dt
(5-360)
(− rB ) = −
dC B = k1C A C B dt
(5-361)
(− rR ) = −
dC R = k 2 C A C R − k1C A C B dt
(5-362)
(− rS ) = −
dC S = k 3C A C S − k 2 C A C R dt
(5-363)
The rate of formation of T is
(+ rT ) =
dC T = k 3C A C S dt
(5-364)
Rearranging Equations 5-360, 5-361, 5-362, 5-363, and 5-364 gives
dC A = −( k1C A C B + k 2 C A C R + k 3C A C S ) dt
(5-365)
dC B = − k1C A C B dt
(5-366)
dC R = k1C A C B − k 2 C A C R dt
(5-367)
dC S = k 2 C A C R − k 3C A C S dt
(5-368)
dC T = k 3C A C S dt
(5-369)
For batch and plug flow reactors:
Introduction to Reactor Design Fundamentals for Ideal Systems
417
dC R k1C A C B − k 2 C A C R = − k1C A C B dC B = −1 +
k 2 CR k1 C B
(5-370)
where R = CR and B = CB:
k R dR = − 1+ 2 dB k1 B
(5-371)
Rearranging Equation 5-371 yields
dR k 2 R − = −1 dB k1 B
(5-372)
Equation 5-372 is a first order differential equation of the form
dy + P( y ) = Q dx e∫
Pdx
I.F. = e ∫
Pdx
dy ∫ Pdx Pdx +e P( y ) = e ∫ Q dx
That is,
d ∫ Pdx ∫ Pdx e y =e Q dx The general solution is e∫Pdxy = ∫e∫PdxQdx + C. The integrating factor of Equation 5-372 is
I.F. = e ∫
Pdx
=e
−∫
K dB B ,
= e − K ln B = e ln ( B)
−K
where P = = B− K
K k1 = B k 2B
418
Modeling of Chemical Kinetics and Reactor Design
Multiplying the integrating factor by both the left and right sides of Equation 5-372 gives dR − K K B ) − R • B− K = − 1 • B− K ( B dB
(5-373)
d (RB− K ) − KRB− K −1 = − B− K dB
(5-374)
or
d (RB− K ) = − B− K dB RB− K = ∫ − B− K dB + Const.
(5-375)
B − K +1 RB− K = − + Const. 1− K
The boundary conditions, at t = 0, B = 1, R = RO
Const = R O + R B− K =
1 1− K
1 − B − K +1 + RO + 1− K 1− K
(5-376)
(5-377)
and
R=
BK − B + R O BK 1− K
The concentration of R is
CR =
CK B − CB 1− K
+ C RO C K B
(5-378)
Introduction to Reactor Design Fundamentals for Ideal Systems
419
The design equations for a CFSTR with perfect mixing, constant fluid density, and steady state operation are as follows. If u is the volumetric flowrate and K = k1/k2, relative reaction rate constant, where k1, k2, and k3 are the specific reaction rate constants for reactions 5-357, 5-358, and 5-359. The rate expressions of A, B, R, S, and T are
(− rA )net
= k1C A C B + k 2 C A C R + k 3C A C S
(− rB )
= k1C A C B
(− rR )
= k 2 C A C R − k1C A C B
(− rS )
= k 3C A C S − k 2 C A C R
(+ rT )
= k 3C A C S
The material balances of components A, B, R, S, and T are:
Input Ouput Disappearance = + + Accumulation rate rate by reaction Mass balance on A is uC AO = uC A + ( − rA ) VR
(5-379)
420
Modeling of Chemical Kinetics and Reactor Design
uC AO = uC A + ( k1C A C B + k 2 C A C R + k 3C A C S )VR
(5-380)
Mass balance on B is uC BO = uC B + ( − rB ) VR
(5-381)
uC BO = uC B + k1C A C B VR
(5-382)
Mass balance on R is
uC RO = uC R + ( − rR ) VR
(5-383)
uC RO = uC R + ( k 2 C A C R − k1C A C B ) VR
(5-384)
Mass balance on S is uC SO = uC S + ( − rS ) VR
(5-385)
uC SO = uC S + ( k 3C A C S − k 2 C A C R ) VR
(5-386)
Mass balance on T is uC TO + ( + rC ) VR = uC T
(5-387)
0 = uC T − k 3C A C SVR
(5-388)
Rearranging Equations 5-382 and 5-384 gives
u(C BO − C B ) = k1C A C BVR
(5-389)
u(C R − C RO ) = ( k1C A C B − k 2 C A C R ) VR
(5-390)
Dividing Equation 5-390 by Equation 5-389 yields C R − C RO ( k1C A C B − k 2 C A C R )VR = C BO − C B k1C A C B VR
(5-391)
Introduction to Reactor Design Fundamentals for Ideal Systems
421
That is,
C R − C RO k C =1− 2 R C BO − C B k1 C B or
R − RO k R =1− 2 BO − B k1 B
(5-392)
Rearranging this equation for R in terms of BO, B, RO, and K = k1/k2 gives
R=
{
B (BO − B) + R O B + K(BO − B)
}
(5-393)
At all t = 0, BO = 1, therefore, R=
B{(1 − B) + R O }
(5-394)
B + K(1 − B)
or
CR =
{
C B (1 − C B ) + C RO C B + K(1 − C B )
}
(5-395)
Davis et al. [9] have performed studies on the batch hydration of ethylene oxide. Their work determined the value of the product distribution constant K. This value is used in Equation 5-378 to determine the expected performance in a plug flow reactor. This value is also used in Equation 5-394 to illustrate the poor performance that would be obtained with complete backmixing. The results show that the plant reactor falls between the plug flow and backmixing reactor lines. The distance between lines (2) and (3) in Figure 5-41 measures the degree of backmixing. There is considerable departure from the theoretical plug flow curve. This shows
422
Modeling of Chemical Kinetics and Reactor Design
Fi gure 5-41. Selectivity and conversion for plant data and well-defined residence time distributions.
that there is room for improvement in the process of eliminating or reducing backmixing. The wide deviation from batch performance is possibly caused by: • Case 1: Backmixing in the reactor. • Case 2: Buildup of ethylene glycol in the recycle to the reactor. • Case 3: Buildup of other reaction products in the recycle. Since the reactors were a series of baffled tanks, Case 1 is most likely. Case 2 can be evaluated quantitatively by using the kinetics applicable to the reaction and making suitable changes to allow for the recycling of ethylene glycol. Case 3 is extremely unlikely because the impurities formed are water-soluble and should, therefore, be removed by the water purged from the system. A longitudinal tubular reactor in place of a high backmixing reactor results in substantial savings in processing costs because selectivity and productivity are increased.
Introduction to Reactor Design Fundamentals for Ideal Systems
423
REFERENCES 1. Levenspiel, O., Chemical Reaction Engineering, 3rd ed., John Wiley, 1998. 3. Adesina, A. A., “Design of CSTRs In Tandem Revisited,” Chemical Engineering Education, pp. 164–168, Summer 1992. 3. Smith, J. M., Chemical Engineering Kinetics, 3rd ed., McGrawHill Book Company, New York, 1981. 4. Carberry, J. J., Chemical and Catalytic Reaction Engineering, McGraw-Hill Book Company, New York, 1976. 5. Schmidt, L. D., The Engineering of Chemical Reactions, Oxford University Press, New York, 1998. 6. Walas, S. M., Chemical Reaction Engineering Handbook of Solved Problems, Gordon and Breach Publishers, 1996. 7. Walas, S. M., Reaction Kinetics for Chemical Engineers, McGrawHill, New York, 1959. 8. Corrigan, T. E., Lessells, A., and Dean, M. J., Ind. & Eng. Chem., Vol. 60, No. 4, April 1968. 9. Davis, et al., Chem. Eng. Prog. Symp. Ser. 48, 4, 1952. 10. Smith, E. L., private communications.
424
Modeling of Chemical Kinetics and Reactor Design
CHAPTER SIX
Non-Isothermal Reactors INTRODUCTION Most chemical reactions are greatly affected by temperature. The previous chapters discussed reactions at isothermal condition, however, industrial reactors often operate under non-isothermal condition. This is because chemical reactions strongly depend on temperature, either absorbing (i.e., endothermic) or generating (i.e., exothermic) a large amount of heat. In non-isothermal conditions, the temperature varies from point to point, as does the composition. In an ideal gas mixture, the concentration of a component depends on the temperature (i.e., Ci = pi/RT), and the reaction rate is greatly affected by the temperature through the rate coefficient (k = koe–E/RT). The reactors described in this chapter operate under both isothermal and non-isothermal conditions. Either a heating/ cooling coil or an external heat exchanger can affect the temperature. Some reaction rates double for a rise in temperature of 10–15oC, and temperature affects the properties of the reaction mixture such as density, specific heat, thermal conductivity and viscosity, enthalpy, as well as mixing patterns and the energy for efficient mixing. Temperature coefficients are not as great as for the rate constant, therefore, averaged values of the physical properties may often be used for design purposes. Some reactors operate under adiabatic conditions, where there is negligible heat input to the reactor. The design of non-isothermal reactors involves the simultaneous solution of both mass and energy balances. In some reactors, such as the packed bed or fluidized catalytic cracking unit (FCCU), momentum balance is considered with both the mass and energy balances. In this section, an energy balance is considered for the CFSTR, batch, and plug flow reactors, and design equations are derived under adiabatic conditions. 424
Non-Isothermal Reactors
425
There are reactions where the heat of reaction can be employed to preheat the feed when an exothermic reaction is operated at a high temperature (e.g., ammonia N2 + 3H2 ↔ 2NH3 or methanol CO + 2H2 ↔ CH3OH synthesis, water-gas shift reaction CO + H2O ↔ H2 + CO2). These processes may be performed in fixed-bed reactors with an external heat exchanger. The exchanger is primarily used to transfer the heat of reaction from the effluent to the feed stream. The combination of the heat transfer-reaction system is classified as autothermal. These reactors are self-sufficient in energy; however, a high temperature is required for the reaction to proceed at a reasonable rate. The following also discusses autothermal reactors, the conversion of ammonia, and finally, the optimum-temperature progression, with derived equations for reversible exothermic reactions for which profiles are not readily available.
OPERATING TEMPERATURE, REACTION TYPES, AND TEMPERATURE The main factors affecting operating temperature are: • Cost of maintaining the operating temperature (energy). • Decomposition temperature of reactants and products. • Possibility of operating at high pressures in the case of gas-phase reactions. • Effect of temperature and pressure on equilibrium in the case of reversible reactions. • Effect of temperature on the rate constants associated with each elementary step in a multiple reaction. • Properties of materials of construction. In irreversible reactions and in accordance with the Arrhenius equation [k = koexp(–E/RT)], it is possible to operate at the highest possible temperature. In reversible reactions, where k1
aA + bB [ rR + sS k2
(6-1)
The equilibrium constant K is related to the Gibbs standard free energy change ∆GoT by
426
Modeling of Chemical Kinetics and Reactor Design
∆G oT = ( rG oR + sG So − aG oA − bG oB ) = − RT ln K
(6-2)
where R = universal gas constant K = k1/k2, equilibrium constant T = absolute temperature (Kelvin) The van’t Hoff equation is expressed as
d ln K ∆H R = dT RT 2 where ∆HR is the heat of reaction, which is a function of temperature. Considering the case where ∆HR is constant and integrating the van’t Hoff equation between the boundary limits gives k2
∆H R R
∫
d ln K =
ln
k2 − ∆H R = k1 R
k1
T2
dT
∫ T2
T1
1 1 − T2 T1
For endothermic reactions, ∆HR has a positive numerical value if T2 > T1 and k2 > k1. The equilibrium constant K, therefore, increases as the temperature increases. In this case, the reactor is operated at the highest possible temperature. For exothermic reactions, ∆HR has a negative numerical value if T2 > T1 and k2 < k1. The equilibrium constant K decreases as the temperature increases. Here, the temperature is kept high so that the rate of reaction is high, and then decreased as equilibrium is approached. PRESSURE AND GAS PHASE REVERSIBLE REACTIONS k1
Consider the reversible reaction of the form aA + bB [ rR + sS. k2 The activity ai of component is ai (Activity of ith component) =
fi fo
Non-Isothermal Reactors
427
where fi = fugacity of ith component in the mixture fo = reference fugacity The equilibrium constant K in terms of the fugacity is expressed as
K=
fR fS o o fR fS
r
s
a
b
f A fB o o f A fB
(6-3)
where foi is usually taken as that of the pure gas at 1 atm, and so fo = 1 atm. Assume that the gas mixture behaves ideally, but the individual gases do not. This yields fi =
x i fi P P
= xi γ iP where xi fi P γi
= = = =
(6-4) mole fraction of i in the mixture fugacity of pure i total pressure fi/P = fugacity coefficient
Substituting for fi and noting that f oi = 1 atm, the equilibrium constant K in terms of the fugacity and total pressure becomes
K=
fRr • fSs fAa • fBb
x r • x sS γ Rr • γ sS ( r + s − a − b ) = aR •P x A • x Bb γ aA • γ Bb
(6-5)
The equilibrium constant K depends only on the temperature and not on the pressure.
428
Modeling of Chemical Kinetics and Reactor Design
Since the product materials are calculated in the number of moles that can be obtained at equilibrium under given conditions of temperature, pressure, and feed composition, Equation 6-5 is modified to give n r • n sS P K = aR Kγ n A • n Bb ∑ n j
( r +s − a − b)
(6-6)
where nj is the number of moles of component j in the reacting system, which also contains nI moles of inert gas. Therefore, xj =
nj n A + n B + n R + nS + n I
and
Ky =
γ Rr • γ sS γ aA • γ Bb
(6-7)
where a, b, r, and s are stoichiometric coefficients From Equation 6-6, the larger the value for K, the higher the yield of the product species at equilibrium. Also, if ∆Go is negative, the values of K will be positive, and results in a large equilibrium conversion of reactants into products. Dodge [1] states the following rules to determine whether a reaction is thermodynamically promising at a given temperature: • ∆G < 0 Reaction is promising • 0 < ∆Go < +10,000 Reaction of doubtful promise, but requires further study. Very unfavorable; would be possible only • ∆Go > + 10,000 under unusual circumstances. For ideal gases,
x r • x sS K = aR • P( r + s − a − b) b xA • xB =
p Rr • psS p aA • p Bb
(6-8)
Non-Isothermal Reactors
429
where pi is the partial pressure of component i.
EFFECT OF OPERATING PARAMETERS ON EQUILIBRIUM CONVERSION TEMPERATURE The effect of temperature on equilibrium composition can be calculated using the van’t Hoff equation. Since the standard heat of reaction is negative (–∆HR) for an exothermic reaction, an increase in temperature results in a decrease in K and a subsequent decrease in conversion. Therefore, an exothermic reaction must be performed at as low a temperature as possible. An endothermic reaction (+∆HR) is positive and K increases with an increase in temperature, as does the equilibrium conversion. Therefore, an endothermic reaction must be performed at an elevated temperature. PRESSURE The equilibrium constant K is independent of pressure with standard states. The effect of the pressure is shown in Equation 6-6. Kγ is usually insensitive and may either increase or decrease slightly with pressure. When (r + s) > (a + b), the stoichiometric coefficients, an increase in pressure P results in a decrease in conversion of the reactants to the products (i.e., A + B ↔ R + S). Alternatively, when (r + s) < (a + b), an increase in pressure P results in an increase in the equilibrium conversion. In ammonia synthesis (N 2 + 3H 2 ↔ 2NH3), the reaction results in a decrease in the number of moles. Therefore, an increase in pressure causes an increase in equilibrium conversion due to this factor.
ENERGY BALANCE AND HEAT OF REACTION From the conservation of energy and assuming a steady-state condition: ENERGY ENERGY ENERGY − = INPUT OUTPUT ACCUMULATION
This is represented in Figure 6-1.
430
Modeling of Chemical Kinetics and Reactor Design
Figure 6-1. Energy balance in chemical reactors, where G = mass flowrate; u = internal energy per unit mass; P = pressure; ρ = fluid density; m = mass of fluid in the system; Q = rate at which heat is transferred to the system; and Ws = rate at which work is done on the surroundings.
Considering the energy balance in this figure, the heat flows into the reactor with the reactant and flows out with the products. The reaction will either generate or absorb heat depending on whether it is exothermic or endothermic. Additionally, stirring the reactants and friction in the CFSTR will generate heat. The heat is finally transferred through the walls. For a CFSTR, assume that the temperature in the system is equal to the temperature at the exit. In other reactor types, the temperature and conversions depend on the position in the reactor. Consider a constant pressure, steady-state flow process with an inflow of reactant in section (1) and the outflow of the product in section (2) leaving the system boundary (i.e., a chemical reactor). During time δt from t to t + δt, the energy balance is expressed as P P G O uO + O δt − G F u F + F δt + Q • δt − Ws • δt ρO ρF d = Accumulation mu + (mu ) • δt − mu dt
Equation 6-9 gives
(6-9)
Non-Isothermal Reactors
P P d − G F u F + F − G O uO + O + Q − Ws = (mu ) ρF ρO dt
431
(6-10)
Equation 6-10 is the macroscopic energy balance equation, in which potential and kinetic energy terms are neglected. From thermodynamics, the enthalpy per unit mass is expressed as h=u +
P ρ
and u =
(6-11)
∑ ui m i i
where u i = internal energy per unit mass of component i mi = mass fraction of i Substituting Equation 6-11 into Equation 6-10 yields
−(G F h F − G O h O ) + Q − Ws =
d (mu ) dt
(6-12)
To use Equation 6-12, a relationship is required between either the internal energy per unit mass u or the enthalpy per unit mass h and the state variables such as the temperature T, pressure P, and composition m i .
(mu ) =
∫ ρu • dVR
VR
and m =
∫ ρ • dVR
VR
Since mixtures are entering and leaving the system, then ui = ∑ m i ui i
where m = mass fraction of component i i u = internal energy per unit mass of mixture This shows that from thermodynamics the enthalpy is a function of the pressure, temperature, and mass fraction of the component, namely
432
Modeling of Chemical Kinetics and Reactor Design
h = f ( p, T, m i )
(6-13)
Differentiating Equation 6-13 with respect to T, p, and m i gives δh = ∑ m i i
∂h i • δp + ∂p
∂h
∑ m i ∂Ti • δT + ∑ δ(m i h i ) i
(6-14)
i
From thermodynamics
∑ mi i
∂h i 1 • δp = • δp ρ ∂p
(6-15)
where
∂h ∂v = v − T ∂T P ∂p T ∂ 1 ρ 1 = − T ρ ∂T P and ∂h
∑ m i ∂Ti • δT = C p • δT
(6-16)
i
where Cp is the specific heat per unit mass of mixture. The last term of Equation 6-14 represents the enthalpy change at constant temperature and pressure due to a change in composition or the degree of conversion. Consider an irreversible reaction of the form aA + bB → cC + dD. The change in enthalpy ∆HR at fixed temperature and pressure is ∆HR = (cHC + dHD – aHA – bHB) where Hi is the enthalpy of 1 mole of component i.
(6-17)
Non-Isothermal Reactors
433
From the stoichiometry, − δm A − δm B + δm C + δm D = = = aM A bM B cM C dM D
(6-18)
where Mi is the molecular weight of component i. Equation 6-16 makes it possible to express changes in composition in terms of the change in mass fraction of a single component. Thus,
∑ δ( m i h i ) i
≡ ∑ h i δm i P, T
(6-19)
i
Assuming that hi’s are independent of composition and − δm A aM A
∑ h iδm i = (cM C h C + dM D h D − aM A h A − bM Bh B ) i
− δm A = (cH C + dH D − aH A − bH B ) • aM A − δm A = ∆H R aM A
(6-20)
Substituting Equations 6-15, 6-16, and 6-20 into Equation 6-14 gives − ∆H R δm A 1 • δh = • δp + C p • δT + a M A ρ
(6-21)
For internal energy per unit mass of mixture 1 − ∆ U R δm A δu = − p • δ + C v • δT + • a MA ρ
(6-22)
434
Modeling of Chemical Kinetics and Reactor Design
ENERGY TRANSFERRED BETWEEN THE SYSTEM AND SURROUNDINGS The transfer of energy between the system and its surroundings involves • Net work done by the system including both mechanical and electrical work, Ws. • Net heat added to the system from all sources, Q. From the energy balance Equation 6-12, the rate at which heat is absorbed by the surrounding into system Q is defined as:
For an endothermic reaction, Q is a positive value, and is defined as Q = U • A • ∆T
(6-23)
where A = heat transfer area of the heating or cooling coil, m2 U = overall heat transfer coefficient, J/m2 • s • K or W/m2K ∆T = temperature difference between the heat transfer fluid and reaction mixture, K For an exothermic reaction Q is a negative value. ADDING HEAT TO THE REACTOR Q In many cases, the heat flow (Q) to the reactor is given in terms of the overall heat transfer coefficient U, the heat exchange area A, and the difference between the ambient temperature, T a, and the reaction temperature, T. For a continuous flow stirred tank reactor (CFSTR) in which both fluid temperatures (i.e., inside and outside the exchanger) are constant (e.g., condensing steam), Q is expressed as
Non-Isothermal Reactors
Q = UA (Ta – T)
435
(6-24)
If the fluid inside the heat exchanger tubes enters the CFSTR at a temperature Ta1 and leaves at a temperature Ta2, and the temperature inside the CFSTR is spatially uniform at temperature T, then the heat flow Q is expressed to the CFSTR by Q = U • A • ∆TLMTD =
UA(Ta1 − Ta 2 ) T −T ln a1 Ta 2 − T
(6-25)
When the heat flow varies along the length of the reactor as in a tubular reactor, Equation 6-25 can be integrated along the length of the reactor to obtain the total heat added to the reactor: A
V
Q = ∫ U( Ta − T )dA = ∫ Ua( Ta − T )dV
(6-26)
where a is the heat exchanger area per unit volume of the reactor. SHAFT WORK Work done Ws by the system on the surrounding generally involves the work done by the stirrer. Any stirring within the reactor will evolve heat. Ws is positive when work is done on the system.
436
Modeling of Chemical Kinetics and Reactor Design
If VR increases at the rate dVR/dt during the chemical reaction, then for a batch system, the work done is defined by
Ws = p •
dVR dt
(6-27) ENERGY BALANCE IN A CFSTR
The following derives an energy balance for a CFSTR based on the following assumptions (Figure 6-2): • • • • • •
Steady state operation Perfect mixing Constant coolant temperature, Tc Stirrer input energy is neglected Ws Constant density of fluid mixture No work done by the system on the surrounding
Figure 6-2. Energy balance in a CFSTR.
Non-Isothermal Reactors
437
Since Ws ≈ 0 and (d/dt)( mu ) = 0, Equation 6-12 becomes –(u1ρ1h1 – uOρOhO) + Q = 0
(6-28)
where G1 = u 1 ρ1 , G O = u O ρO
(6-29)
and hi = ( u + Pi/ρi). Since the condition is at steady state, then u1ρ1 = uOρO = uρ
(6-30)
In many practical situations, ρ1 = ρO and, therefore, u1 = uO, and Equation 6-28 becomes –uρδh + Q = 0 or –Gδh + Q = 0
(6-31)
The heat input Q is Q = U • A • (TC – T1)
(6-32)
Substituting Equations 6-30 and 6-32 into Equation 6-28 yields –uρ(h1 – hO) + UA(TC – T1) = 0
(6-33)
From Equation 6-21 h1
T1
m A1
hO
TO
m AO
∫ dh = ∫ C pdT + ∫
− ∆H R dm A a MA
(6-21)
438
Modeling of Chemical Kinetics and Reactor Design
Considering the thermodynamic paths h1
Path 1:
∫
dh =
hO
h1
Path 2:
∫
T1
∫
C p Feed dT +
TO
dh =
hO
T1
∫
m A1
∫
m AO
C Product dT +
TO
− ∆H R dm A a T MA 1
m A1
∫
m AO
− ∆H R dm A a T MA O
(6-34)
(6-35)
Both path 1 or path 2 can be considered for the heat balance equation for a CFSTR. In the case of path 1, T1
− ∆H R − uρ ∫ C p dT − uρ ( m A1 − m AO ) + UA(TC − T1 ) = 0 a MA T T
(6-36)
1
O
In many practical cases, Cp does not significantly change with composition. Equation 6-36 becomes − ∆H R − uρC p (T1 − TO ) − uρ ( m A1 − m AO ) + UA(TC − T1 ) = 0 (6-37) aM A By definition, C ′A ≡
m A moles m A moles mass • ρ • and C A = M A unit mass M A unit mass volume
The heat balance of a CFSTR in terms of the concentration CA for component A in Equation 6-37 after rearrangement becomes uρC p (TO − T1 ) + u
− ∆H R (C AO − C A1 ) + UA(TC − T1 ) = 0 a
(6-38)
A mass balance on component A in a CFSTR gives uCAO = uCA1 + (–rA1)VR
(5-158)
Non-Isothermal Reactors
or u(CAO – CA1) = (–rA1)VR
439
(5-158a)
Substituting Equation 5-158a into Equation 6-38 gives − ∆H R uρC p (TO − T1 ) + (− r ) V + UA (TC − T1 ) = 0 a A1 R
(6-39)
For multiple reaction systems, Equation 6-39 becomes
uρC p (TO − T1 ) +
R
∑ i =1
− ∆H Ri (− rAi ) VR + UA (TC − T1 ) = 0 (6-40) a
For a first order irreversible reaction, the energy balance is expressed in terms of the fractional conversion XA, where XA =
C AO − C A C AO
CAO – CA = CAOXA Equation 6-38 now becomes uρC p (TO − T1 ) + uC AO X A
− ∆H R + UA (TC − T1 ) = 0 a
(6-41)
If the temperature in the product is the same as the inlet temperature of the reactant (i.e., TO = T1), in which isothermal condition prevails, then Equation 6-38 becomes u
− ∆H R (C AO − C A1 ) = UA(T1 − TC ) a
(6-42)
Or, in terms of the fractional conversion, uC AO X A
− ∆H R = UA(T1 − TC ) a
(6-43)
In an isothermal (constant temperature) reactor as much heat is needed to be supplied from or rejected into the surroundings, as is
440
Modeling of Chemical Kinetics and Reactor Design
absorbed or given up by the reaction. In this type of operation, high costs of the equipment are required and, therefore, reactors under isothermal conditions are seldom employed in large-scale manufacturing. Generally, commercial reactors are either adiabatic or polytropic types. In an adiabatic reactor, no heat is added or taken away during the process, and that given up by the reaction is solely used within the system to change its enthalpy. In a polytropic reactor, the heat necessary to sustain the process is either added or taken away from the system. The following example reviews some design problems involving the simultaneous solution of both the mass and energy balances in a CFSTR. Example 6-1
An endothermic reaction A → R is performed in three-stage, continuous flow stirred tank reactors (CFSTRs). An overall conversion of 95% of A is required, and the desired production rate is 0.95 × 10–3 kmol/sec of R. All three reactors, which must be of equal volume, are operated at 50°C. The reaction is first order, and the value of the rate constant at 50°C is 4 × 10–3 sec–1. The concentration of A in the feed is 1 kmol/m3 and the feed is available at 75°C. The contents of all three reactors are heated by steam condensing at 100°C inside the coils. The overall heat transfer coefficient for the heat-exchange system is 1,500 J/m2 • sec • °C, and the heat of reaction is +1.5 × 108 J/kmol of A reacted. Calculate (1) the size of the tanks in the reactor system, and (2) the areas of the heating coil in each tank. Data: Reaction rate constant = 4 × 10–3sec–1 Liquid density = 1,000 kg/m3 Specific heat = 4 × 103 J/kg • °C Molecular weight of A = 100 kg/kmol Solution Assume the following: • Perfect mixing • Steady-state operation (i.e., accumulation in the reactor is zero)
Non-Isothermal Reactors
441
• Constant fluid mixture density • Stirrer input energy is neglected Ws • No work done by the system on the surroundings k
For A 1 → R, first order endothermic reaction, the rate of reaction is (–rA) = K1CA.
Battery of continuous flow stirred tank reactors (CFSTRs)
The notations are: A1, A2 , A 3 = CAO = CA1, CA2, CA3 = FAO = u= ρ= Cp = U= MA = VR = t = (+∆HR) =
areas of the heating coil initial concentration to CFSTR 1 concentrations in CFSTR 1, 2, and 3, respectively desired production rate fluid volumetric flowrate liquid density liquid specific heat overall heat transfer coefficient molecular weight of A volume of the reactor mean residence time (VR/u) enthalpy of reaction (endothermic)
442
Modeling of Chemical Kinetics and Reactor Design
To = T 1, T2 , T 3 = Th = XA =
inlet temperature to the first CFSTR temperatures in the CFSTRs temperature of the heating coils overall fractional conversion of A
For a CFSTR, mass balance for the Nth stage is CAO/CAN = (1 + kt )N. The mass balance for the first stage of the CFSTR on component A is uCAO = uCA1 + (–rA)VR + VR(dCA1/dt). Accumulation is zero, which yields VR(dCA1/dt) = 0, and the rate of disappearance of component A is (–rA) = k1CA1. Hence, uCAO = uCA1 + k1CA1VR. Rearranging, the exit concentration from the first stage of the CFSTR is CA1 = CAO/(1 + k1t ). The exit concentration from the first stage is now the input concentration to the second stage of the CFSTR. Material balance on the second stage is uCA1 = uCA2 + k1C A2V R. Rearranging for the exit concentration of the second stage CFSTR yields CA2 = CA1/(1 + k1t ). In terms of the inlet concentration, the exit concentration of the second stage becomes CA2 = CAO/(1 + k1t )2. The exit concentration from the second stage is now the input concentration to the third stage of the CFSTR. Material balance on the third stage CFSTR is uCA2 = uCA3 + k1CA3VR. Further rearranging gives the exit concentration from the third stage CFSTR as CA3 = CA2/(1 + k1t ). In terms of the inlet concentration, the exit concentration of the third stage becomes CA3 = CAO/(1 + k1t )3. The overall conversion of 95% of A indicates that XA =
C AO − C AF C AO − C A 3 95 = = C AO C AO 100
That is
1−
C A3 = 0.95 C AO
C A 3 = 0.05 C AO
where
C AO =1
kmol m3
Non-Isothermal Reactors
C A3 = 0.05
kmol m3
C AO 3 = (1 + k1t ) C A3 That is, (1 + k1t )3 = 20, or
1 + k1t = 2.714 k1t = 1.714
k1
VR = 1.714 u
VR 1.714 = = 428.5 sec u 4 × 10 −3 u = volumetric flowrate of A in m3/sec, =
Desired production rate 1 × An overall conversion Concentration of A in the feed
0.95 × 10 −3 1 kmol 1 = × × kmol 0.95 1 sec m3
= 1.0 × 10 −3
m3 sec
The size of the reactor VR is VR = 428.5 × u = 428.5 × 10–3m3 = 0.429 m3
443
444
Modeling of Chemical Kinetics and Reactor Design
The heat balance operation at constant pressure on the first stage CFSTR is –G∆h + Q = 0, where G = ρu and Q = heat absorbed to the reactor tanks. Q = +UA(Th – T1) where − ∆H R ∆m A ∆h = C p ∆T + a MA The heat balance equation is expressed as: − ∆H R ∆m A − uρC p ∆T − uρ + UA1 (Th − T1 ) = 0 a M A
CA =
moles mA mass = C ′A • ρ × MA unit mass volume
− uρC p (T1 − TO ) + u
+ ∆H R (C A1 − C AO ) + UA1 (Th − T1 ) = 0 a
The mass balance on the first stage CFSTR.
C A1 =
C AO 1 + k 1t
C AO = 1
kmol m3
t = 428.5 sec k1 = 4 × 10 −3 sec −1
C A1 =
1 (1 + 4 × 10 −3 × 428.5)
Non-Isothermal Reactors
= 0.3685
C A1 = 0.369
CA2 = =
445
kmol m3
kmol m3
C AO
(1 + k1t )2
(1 + 4 × 10
C A2 = 0.136
1 −3
× 428.5)
2
kmol m3
Since the reaction is endothermic (+∆HR/a), then the heat balance for the first stage is: − uρC p (T1 − TO ) + u
+ ∆H R (C A1 − C AO ) + UA1 (Th − T1 ) = 0 a
–1 × 10–3 × 103 × 4 × 103 (50 – 75) + 10–3 × 1.5 × 108 × (0.369 – 1.0) + 1,500 × A1(100 – 50) = 0 100,000 – 94,650 + 75,000A1 = 0 A1 =
−5, 350 75, 000
= −0.0713 m 2 The negative value in the area indicates that the first stage of the CFSTR requires a cooling coil. The second stage CFSTR gives − uρC p (T2 − T1 ) + u
+ ∆H R (C A 2 − C A1 ) + UA 2 (Th − T2 ) = 0 a
446
Modeling of Chemical Kinetics and Reactor Design
Since T1 = T2 (i.e., isothermal condition), then
u
+ ∆H R (C A 2 − C A1 ) = − UA 2 (Th − T2 ) a
10–3 × 1.5 × 108(0.136 – 0.369) = –1,500 × A2(100 – 50) A2 =
−0.3495 × 10 5 = 0.466 m 2 −75, 000
C A3 = =
C AO
(1 + k1t )3 1
(1 + 4.0 × 10 −3 × 428.5)3
= 0.05
kmol m3
Heat balance on the third stage CFSTR is
+ ∆H R − uρC p (T3 − T2 ) + u (C − C A 2 ) + UA 3 (Th − T3 ) = 0 a A3 Since T2 = T3 (i.e., isothermal condition), then u
+ ∆H R (C A3 − C A 2 ) = − UA 3 (Th − T3 ) a
1 × 10–3 × 1.5 × 108(0.05 – 0.136) = –1,500 × A3(100 – 50)
A3 =
− 10 −3 × 1.5 × 108 × 0.086 = 0.172 m 2 −75, 000
The calculations show that the volume of each reactor is 0.429 m3 and a heating coil is not required in the first CFSTR, whose area is 0.0713 m2. The areas of the subsequent heating coils are 0.466 m2 and
Non-Isothermal Reactors
447
0.172 m2, respectively. An Excel spreadsheet program (Example6-1.xls) was developed for this example.
Example 6-2
A second order, liquid phase reaction, A + B → C, is to be performed in a single-stage CFSTR. Given the following data: 1. Determine the size of the reactor required to achieve 85% conversion of A. 2. Estimate the heat-transfer area needed to maintain the reactor temperature at 27oC. 3. Calculate what the feed temperature must be if the reactor is to be operated adiabatically at 27oC. Volumetric flowrate
0.002 m3/sec
Feed compositions: A B
1.0 kmol/m3 1.0 kmol/m3
Rate constant
0.01 m3/kmol • sec
Feed temperature
27°C, except for Part 3
Heat of reaction
–6 × 104 kJ/kmol of A
Mixture density (constant)
800 kg/m3
Mixture specific heat (constant)
3.5 kJ/kg • K
Overall heat-transfer coefficient
2.0 kJ/m2sec • K
Coolant temperature
10°C
Fractional conversion of A, XA
0.85
Solution Assuming the following: • • • • •
Perfect mixing Steady-state operation (i.e., accumulation in the reactor is zero) Constant fluid mixture density Stirrer input energy is neglected Ws No work done by the system on the surroundings
448
Modeling of Chemical Kinetics and Reactor Design
The rate of reaction is (–rA) = kC ACB. The material balance on component A is uCAO = uCA + (–rA)VR or uCAO = uCA + kCACBVR. The fractional conversion is XA = 0.85 = (CAO – CA)/CAO or
C A = C AO (1 − X A )
C AO − C A = C AO X A
= 1.0(1 − 0.85)
= 1.0 × 0.85
= 0.15
= 0.85
From stoichiometry, CAO – CA = CBO – CB, or CB = CBO – (CAO – CA) = CBO – CAOXA The material balance on component A in terms of the original concentrations of A and B is uC AO = uC AO(1 – XA) + kCAO(1 – XA)(CBO – CAOXA)VR. That is, 0.002 × 1.0 = 0.002 × 1(1–0.85) + 0.01 × 1 × (1.0 – 0.85)(1.0 – 1.0 × 0.85)VR
Non-Isothermal Reactors
449
0.002 = 0.0003 + 0.000225VR VR = 7.56 m3 The heat balance is –G∆h + Q = 0 or –ρu∆h + UA(TC + T1) = 0, where ∆h = C p ∆T +
− ∆H R ∆m A a MA
− ∆H R ∆m A + UA(TC − T1 ) = 0 −ρu C p ∆T + a M A −ρuC p (T1 − TO ) − u
− ∆H R (C A − C AO ) + UA(TC − T1 ) = 0 a
Rearranging the above equation gives ρuC p (TO − T1 ) + u
− ∆H R (C AO − C A ) = UA(T1 − TC ) a
where TO = T1 = 27°C (isothermal condition). Therefore, ρuCP (TO – T1) = 0, which gives UA(T1 − TC ) = u
− ∆H R (C AO − C A ) a
The heat transfer area A is
A=
u
− ∆H R (C AO − C A ) a U (T1 − TC )
0.002(6 × 10 4 )(1.0 − 0.15) m 3 kJ kmol m 2 o C • sec 1 = • • 3 • •o kJ C 2.0 (27 − 10) sec kmol m = 3 m2
450
Modeling of Chemical Kinetics and Reactor Design
At the adiabatic condition, Q = 0, as no heat is added to or removed from the system. The heat balance becomes −ρuC p (T1 − TO ) − u
− ∆H R (C A − C AO ) = 0 a
or ρuC p (TO − T1 ) = u
or TO = T1 +
= 27 +
− ∆H R (C A − C AO ) a
1 − ∆H R (C A − C AO ) ρC p a
m 3 kJ kmol kg •o C 1 • • 3 • 6 × 10 4 ) (0.15 − 1.0) ( kJ (800)(3.5) kg kmol m
= 27 − 18.2 TO = 8.8°C An Excel spreadsheet program (Example6-2.xls) was developed for this example. Example 6-3
The unsteady state equations for a CFSTR involving a second order reaction with constant heat input are: −E
Mass balance: VR
dC A = u(C AO − C A ) − k O VR C 2A e RT dt
Heat balance: VR ρC P
−E
− ∆H R dT = uC p (TO − T ) + k V C 2 e RT + Q S a O R A dt
where QS = mS∆HV. Calculate the outlet concentration and temperature of the reactor with the following data.
Non-Isothermal Reactors
451
Reactor feed rate, u
0.1 ft3/sec
Reactor inlet concentration, CAO
1 lb-mol/ft3
Reactor volume, VR
100 ft3
Arrhenius pre-exponential factor, k O
1.907 × 1013 ft/lb-mol • sec
Activation energy, E
44,700 Btu/lb-mol
Gas constant, R
1.987 Btu/lb-mol oR
Specific heat capacity, CP
0.75 Btu/lb oR
Reactor inlet temperature, TO
600°R
Heat of reaction, ∆HR
10,000 Btu/lb-mol
Steam flowrate, mS
0.711 lb/sec.
Heat of vaporization of steam, ∆HV
960 Btu/lb
Solution density, ρ
80.0 lb/ft3
Solution The mass and energy balance equations are expressed respectively as −E
dC A u = Mass balance: (C AO − C A ) − k OC2A e RT dt VR −E
− ∆H R k C 2 e RT a O A QS dT u Energy balance: = TO − T ) + + ( ρC P dt VR VR ρC P where QS = mS∆HV. The two equations are coupled with the temperature and concentration in both mass and heat balances. A computer program CFSTR61 using the Runge-Kutta fourth order method with a step increment for the time ∆t = 10.0 sec was employed to determine both the outlet concentration and temperature for a period of 2,000 sec. Table 6-1 gives typical results from the program and Figure 6-3 shows both concentration and temperature profiles with time. The profiles show that at constant heat input, there is a gradual decrease in the outlet concentration until about 100 sec, which is then followed by a steep decrease until the effluent concentration reaches a steady state at about 2,000 sec. There is a corresponding gradual rise in temperature until about 100 sec, which is followed by a steep increase in the outlet temperature until it reaches a steady value at about 2,000 sec.
452
Modeling of Chemical Kinetics and Reactor Design
Table 6-1 The reactor outlet concentration and temperature of a CFSTR with constant heat input Time sec
Outlet concentration lb-mols/ft3
Outlet temperature °R
0.0 10.0 20.0 30.0 40.0 50.0 100.0 200.0 400.0 600.0 800.0 1,000.0 1,200.0 1,400.0 1,600.0 1,800.0 2,000.0
0.5230 0.5229 0.5228 0.5227 0.5224 0.5221 0.5200 0.5138 0.4998 0.4870 0.4765 0.4679 0.4609 0.4552 0.4505 0.4467 0.4436
609.2 609.4 609.7 609.9 610.1 610.3 611.1 612.2 613.6 614.5 615.3 615.9 616.4 616.8 617.1 617.4 617.6
Example 6-4
A solution containing 0.25 kmol/m3 of acetic anhydride is to be hydrolyzed in a single CFSTR to give an effluent containing an anhydride concentration of 0.05 kmol/m3. The volumetric flowrate is 0.05 m3/min and the working volume of the reactor is 0.75 m3. (1) Show that the reactor temperature must be maintained at 34°C given that the reaction is first order with respect to anhydride concentration and the rate constant k can be determined from the relationship k = 0.158 exp18.55 −
5, 529 min −1 T
where T is the temperature (K). (2) Given the following design data, determine (a) under what conditions adiabatic operation is feasible, and (b) what cooling area is required if the feed temperature is 30°C?
Non-Isothermal Reactors
453
Figure 6-3. Profiles of outlet temperature and concentration with time in a CFSTR.
454
Modeling of Chemical Kinetics and Reactor Design
Heat of reaction
–5 × 104 kcal/kmol of anhydride
Mixture density (constant)
950 kg/m3
Mixture specific heat
0.95 kcal/kg • °C
Overall heat-transfer coefficient
8 kcal/m2 min • °C
Cooling water is available at either
15°C or 25°C
Solution The hydrolysis of acetic anhydride is CH3CO • O • COCH3+H2O → 2CH3COOH or A + B → 2C, where component A is the acetic anhydride. The rate expression is first order in terms of component A.
Assume the following: • • • • •
Perfect mixing Steady-state operation (i.e., accumulation in the reactor is zero) Constant fluid mixture density Stirrer input energy is neglected Ws No work done by the system on the surroundings
Non-Isothermal Reactors
455
The rate expression is (–rA) = kCA, where k = 0.158 exp(18.55 – 5,529/T). The material balance on component A gives uCA = uCA + (–rA)VR. That is, 18.55 − 5, 529 T
uC AO = uC A + 0.158 e
C A VR
where CAO = 0.25 kmol/m3, CA = 0.05 kmol/m3, VR = 0.75 m3, and u = 0.05 m3/min. This yields 0.05 × 0.25 = 0.05 × 0.05 + 0.158 e
18.55 − 5, 529 T
(0.05)(0.75)
18.55 − 5, 529 T
0.0125 = 0.0025 + 0.005925 e
Further rearrangement gives the temperature T = 306.7 K, which is T = 306.7 – 273.15 = 33.55°C (≈34°C) The operation might be feasible under adiabatic conditions when no heat is added or removed from the reactor (i.e., Q = 0), and the heat given up by the reaction is entirely used within the system to change its enthalpy. The inlet temperature of feed reactant is determined as follows. Consider the energy balance: –G∆h + Q = 0 where G = ρu and ∆h = C p ∆T +
− ∆H R ∆m A a MA
This gives
− ∆H R ∆m A +Q= 0 −ρu C p ∆T + a M A
(6-31)
456
Modeling of Chemical Kinetics and Reactor Design
−ρuC p (T1 − TO ) − u
− ∆H R (C A − C AO ) = 0 a
Rearranging the above equation gives ρuC p (TO − T1 ) = u
TO − T1 =
− ∆H R (C A − C AO ) a
1 − ∆H R (C A − C AO ) ρC p a
TO − 34.0 =
1
(950)(0.95)
(5 × 10 4 )(0.05 − 0.25)
kcal m 3 kg •o C kmol × • • • 3 m kmol A kg kcal TO – 34.0 = –11.08 TO = 22.92°C From the heat balance
−ρuC p (T1 − TO ) − u
− ∆H R (C A − C AO ) + UA(TC − T1 ) = 0 a
Rearranging to determine the area of the heating coil, gives − ∆H R ρ u C p (TO − T1 ) + u (C − C A ) a AO A= U(T1 − TC ) where TO = 30°C, TC = 15°C, and knowing the other parameters Area =
950 × 0.05 × 0.95(30.0 − 34.0) + 0.05(5 × 10 4 )(0.25 − 0.05) 8(34.0 − 15.0)
Non-Isothermal Reactors
457
Area = 2.10 m2 Therefore, the cooling coil area for the first stage CFSTR is 2.1 m2. An Excel spreadsheet program (Example6-4.xls) was developed for this example.
BATCH REACTOR Consider a batch reactor as shown in Figure 6-4 with a heat exchange system. There is no flow into or out of the reactor. It can be assumed that the total mass of the mixture, m, is constant and allowing for a change in volume, VR, from Equation 6-12 gives (no flow implies that GO = GF = 0) −(G F h F − G O h O ) + Q − WS =
d (mu ) dt
Figure 6-4. Batch reactor with heating coil.
(6-12)
458
Modeling of Chemical Kinetics and Reactor Design
where Q Q U A Th T
= = = = = =
UA(Th – T) heat transfer rate, J/s overall heat transfer coefficient, J/m2 • s • K, W/m2 • K area of the heating/cooling coil, m2 temperature of the heating coil, K (assumed constant) temperature of the reacting system, K
Q − Ws = m
du dt
(6-44)
The work done by the system is represented by
Ws = P
dVR dt
where P = total pressure dVR/dt = rate of volume expansion The work done by the agitator on the system may also have to be considered. However, at constant pressure (e.g., open system)
u=h−
P ρ
(6-11)
Differentiating Equation 6-11 with respect to time and multiplying by m gives
m
du dh d P =m −m dt dt dt ρ =m
dV dh −P R dt dt
(6-45)
From Equation 6-21 m
− ∆H R dm A dh dT = m Cp + m dt dt aM A dt
Using these relationships in Equation 6-44 gives
(6-46)
Non-Isothermal Reactors
Q −P
dVR du =m dt dt =m
Q=m
459
dV dh −P R dt dt
dh dt
Q = mC p
− ∆H R dm A dT + m dt aM A dt
(6-47)
At constant volume (e.g., autoclave), using Equations 6-22 and 6-44, Q = mC v
− ∆U R dm A dT + m dt aM A dt
(6-48)
METHODS FOR SOLVING DESIGN EQUATIONS From the mass balance equation for a batch reactor
(− rA )VR =
− dN A dt
(5-6)
and at constant volume and density NA mA ≡ • ρ VR MA
(6-49)
Substituting Equation 6-49 into Equation 5-6 gives
(− rA )VR =
−ρ VR dm A • MA dt
(6-50)
These relationships enable the combination of the mass and the energy balances. For constant volume and density, with m = ρVR,
− dm A − M A dN A MA • = = (− rA ) VR dt m dt m
(6-51)
460
Modeling of Chemical Kinetics and Reactor Design
The mass and energy balances usually must be solved simultaneously by using numerical methods. Equation 6-47 becomes Q = mC p
dN A − ∆H R dT + dt dt a
or Q = mC p
− ∆H R dT − ( − rA ) VR a dt
(6-52)
(6-53)
Rearranging Equation 6-53 and using m = ρVR yields
(− rA ) − ∆H R + UA T − T dT = ( h ) ρC p a ρVR C p dt
(6-54)
For adiabatic conditions, Equation 6-54 becomes
(− rA ) − ∆H R dT = ρC p a dt
(6-55)
In terms of the fractional conversion XA, Equation 6-52 becomes Q = mC p
− ∆H R dX A dT − N AO dt a dt
(6-56)
For adiabatic condition (i.e., Q = 0), Equation 6-56 gives
mC p
− ∆H R dX A dT = N AO dt a dt
(6-57)
Since the relationship between dT/dt and dXA/dt is implicit with respect to time t, Equation 6-57 is expressed as
mC p dT = N AO
or T − TO =
− ∆H R dX A a
N AO
− ∆H R (X A − X AO ) a mC p
(6-58)
(6-59)
Non-Isothermal Reactors
461
where TO and XAO = initial temperature and fractional conversion (i.e., initial conditions in the reactor) NAO = initial moles Rearranging Equation 6-59 gives
T = TO +
N AO
− ∆H R (X A − X AO ) a mC p
(6-60)
In an adiabatic operation, Q = 0, and as such there is no attempt to heat or cool the contents in the reactor. The temperature T in the reactor rises in an exothermic reaction and falls in an endothermic reaction. It is essential to control T so that it is neither too high nor too low. To assess the design of both the reactor and the heat exchanger required to control T, the material and energy balance equations must be used together with information on rate of reaction and rate of heat transfer because there is an interaction between T and XA. The time required to achieve fractional conversion XA from the mass balance can be determined as t = N AO
X AF
dX
∫ (− rA )AVR X
(6-61)
AO
Example 6-5
Consider the reaction A → B, (–rA) = kC A, k350 = 0.65 min–1, (–∆H R/a) = 30(kcal/mol) in a 10-l batch reactor with initial concentration of A = 2 mol/l and temperature To = 350 K. Determine the heat transfer rate required to maintain the temperature at 350 K at 95% conversion. Solution For the batch reactor with a first order reaction, the rate expression is
(− rA ) = kC A = −
dC A dt
462
Modeling of Chemical Kinetics and Reactor Design
The concentration of A after integration and mathematical manipulation is CA = CAOe–kt. The rate expression now becomes (–rA) = kCAOe–kt, where k is constant. The rate of heat transfer Q can be determined from Equation 6-53 as
Q = mC p
− ∆H R dT − ( − rA )VR a dt
(6-53)
Under isothermal conditions, dT/dt = 0, and Equation 6-53 becomes Q = − ( − rA )VR
− ∆H R a
(6-62)
Substituting the rate expression into Equation 6-62 gives Q = − kC AO exp( − kt )VR
− ∆H R 1 mol kcal • •l• a mol min l
Q = –0.65 × 2.0 e–0.65t × 10 × 30 Q = –390e–0.65t(kcal/min). Since Q < 0, it shows that heat is removed from the system, which is undergoing exothermic reaction. The time corresponding to a 95% conversion for the first order reaction is determined by
t = N AO
X AF
dX
∫ (− rA )AVR X AO
or t =
1 k
=− t=−
X AF = 0.95
∫
X AO= 0.0
dX A (1 − X A )
1 X = 0.95 ln[1 − X A ]X AF = 0.0 AO k
1 [ln(1 − 0.95) − ln (1 − 0)] 0.65
t = 4.6 min
(6-61)
Non-Isothermal Reactors
463
The heat transfer rate (Qt≡95%) at 95% conversion is Q = –390e–0.65 × 4.608 = –19.51 kca/min An Excel spreadsheet program (Example6-5.xls) was developed for this exercise. Example 6-6
Consider a non-isothermal batch reactor that is operated adiabatically. The reactor contains a liquid reaction mixture in which the reaction k A → Products occurs, where (–rA) = kCA and k = kOe–E/RT, where CA E R T kO
= = = = =
concentration of A activation energy of the reaction gas constant absolute temperature pre-exponential factor
Determine the concentration and temperature after 180 sec if the initial concentration and temperature of A are CA = 1.0(gmol/l), T = 300 K, and E/R = 300 K. Solution
464
Modeling of Chemical Kinetics and Reactor Design
Assume perfect mixing in the reactor, and because it is operated adiabatically (i.e., no exchange of heat between the reactor and its environment), Q = 0 and equation 6-53 becomes
mC p
− ∆H R dT = ( − rA )VR dt a
dT or = dt
(− rA )VR
− ∆H R a
mC p
(6-63)
(6-64)
Assuming the density of the mixture is constant, then ρ = m/VR, and with CP taken as the average heat capacity of the reacting mixture, Equation 6-64 becomes
dT = dt
− ∆H R a ρC p
(− rA )
(6-65)
(–∆HR/a) is the heat of reaction, which is a function of temperature, but it is assumed constant. The rate expression for a first order reaction is (–rA) = kOCAe–E/RT. Substituting the rate expression into Equation 6-65 gives
dT = dt
k O C A e − E RT ρC p
− ∆H R a
(6-66)
The unsteady state mass balance is (–rA) = –(dCA/dt) = kCA
or
dC A = − k O C A e − E RT dt
(6-67)
Equations 6-66 and 6-67, respectively, are two coupled first order differential equations. This is because dCA/dt is a function of T and CA while dT/dt is also a function of CA and T. The Runge-Kutta fourth
Non-Isothermal Reactors
465
order numerical method can be applied with initial boundary conditions to simulate both concentration and temperature with time. In Equation 6-67, K1 = –kO = –0.1 sec–1, and in Equation 6-66,
K2 =
kO
− ∆H R a = 1.0 l − K ρC p gmol − sec
By expressing Equations 6-66 and 6-67 in the form
dC A = K1C A e − E RT dt and
(6-68)
dT = K 2 C A e − E RT dt
(6-69)
respectively, a computer program BATCH61 was developed to simulate the concentration and temperature with time of the adiabatic batch system. Table 6-2 gives the results of the program and Figure 6-5 shows both concentration and temperature profiles with time A in the system. Example 6-7
Acetylated castor oil is hydrolyzed for the manufacture of drying oils in kettles operated batchwise. Grummit and Fleming (1945)* correlated the decomposition data on the basis of a first order reaction as: Acetylated castor oil (1) → CH3COOH (g) + drying oil (1) r = kC where r = the rate of decomposition (kg of acetic acid produced per m3/min) C = concentration of acetic acid, kg/m3 The batch reactor initially contains 227 kg of acetylated castor and the initial temperature is 613 K. Complete hydrolysis yields 0.156 kg acetic acid per kg of ester. For this reaction, the specific reaction rate constant k is *
Ind. Eng. Chem., 37, 485 (1945).
466
Modeling of Chemical Kinetics and Reactor Design
Table 6-2 Simulation of a non-isothermal batch reactor
k = exp 35.2 −
22, 450 1 T min
(6-70)
where T is the temperature, K. The specific heat of the liquid reaction mixture is constant at 0.6 cal/gm-K, molecular weight of acetic acid (MA) is 60 g/gmol, and the endothermic heat of reaction is (+∆HR/a) = 15,000 cal/gmol of acid produced. 1. Find the relationship between T and the fraction converted for several values of heat input rate, Q = kcal/min. 2. If the batch operation is adiabatic, find the relationship between the conversion (fraction of the acetylated oil that is decomposed) and temperature versus time.
Non-Isothermal Reactors
Figure 6-5. Simulation of a non-isothermal batch reactor.
467
468
Modeling of Chemical Kinetics and Reactor Design
Solution (1) Rearranging Equation 6-56 yields
mC p
− ∆H R dX A dT = Q + N AO a dt dt
(6-71)
Moles of acetic acid NAO is N AO =
gmol kg acetic acid 227, 000 × 0.156 g • 60 g kg ester
= 590.2 gmol of acetic acid Rearranging Equation 6-71, the energy balance equation becomes
dT = dX A
Q
+ ∆H R dt − N AO a dX A mC p
(6-72)
From the mass balance, and assuming no change in volume for a first order reaction, gives
−
1 dN A = ( − rA ) = kC A VR dt
In terms of the fractional conversion, XA dX A = k(1 − X A ) dt
or
1 dt = dX A k(1 − X A )
(6-73)
(6-74)
Substituting Equation 6-74 into Equation 6-72 gives
+ ∆H R Q − N AO a k(1 − X A ) dT = dX A mC p
(6-75)
Non-Isothermal Reactors
where m Cp NAO (+∆HR/a)
= = = =
469
227 kg 0.6 cal/g • K 590.2 gmol 15.0 kcal/gmol
Equation 6-75 becomes Q − (590.2)(15) k(1 − X A ) dT = dX A (227)(0.6) Q − 8, 853 k(1 − X A ) dT or = 136.2 dX A
(6-76)
Equation 6-76 is a first order differential equation. Using the RungeKutta fourth order method, it is possible to simulate the temperature at different conversion for varying value of the heat transfer rate Q (kcal/min). A simulation exercise was performed for Q = 0, 500, 1,000, 1,250 and 1,500 kcal/min, respectively, using a developed computer program BATCH62. Table 6-3 gives the computer results and Figure 6-6 shows profiles of the simultaneous solutions of Equations 6-70 and 6-76 for several values of Q. It is seen that the temperature drops drastically for the endothermic reaction with adiabatic operation (i.e., Q = 0), implying that heating should be considered. (2) The mass balance expression in terms of the fractional conversion assuming no change in volume is dt 1 = dX A k(1 − X A )
(6-74)
where the specific reaction rate constant k depends on the temperature and is expressed by k = exp 35.2 −
22, 450 1 T min
(6-70)
The reactor temperature T is determined by Equation 6-60 as
470
Modeling of Chemical Kinetics and Reactor Design
Table 6-3 Simulation of a batch reactor for the hydrolysis of acetylated castor oil
Non-Isothermal Reactors
471
Figure 6-6. Temperature versus fractional conversion profiles for various rates of heat input in a batch reactor.
T = TO +
or T = TO −
N AO
− ∆H R (X A − X AO ) a mC p
N AO
+ ∆H R (X A − X AO ) a mC p
(6-60)
(6-77)
where (+∆HR/a) = endothermic enthalpy of reaction TO = 613 K XAO = 0 Substituting numbers in Equation 6-77 gives T = 613 −
(590)(15.0) X (227)(0.6) A
T = 613 – 65XA
(6-78)
472
Modeling of Chemical Kinetics and Reactor Design
Equation 6-74 is a first order differential equation; substituting Equations 6-70 and 6-78 for the temperature, it is possible to simulate the temperature and time for various conversions at ∆XA = 0.05. Table 6-4 gives the computer results of the program BATCH63, and Figure 6-7 shows profiles of both fractional conversion and temperature against time. The results show that for the endothermic reaction of (+∆H R/a) = 15.0 kcal/gmol, the reactor temperature decreases as conversion increases with time.
PLUG FLOW REACTOR For Figure 6-8 the notations are: C ′A G ρ CP T ∆HR dt TC U S
= = = = = = = = = = =
moles per unit mass of species A mass flowrate fluid density fluid heat capacity fluid temperature enthalpy of reaction tube diameter temperature of coolant fluid is constant overall heat transfer coefficient cross-sectional area of the tubular reactor (πd 2t /4 for a cylindrical tube)
Table 6-4 Simulation of a non-isothermal reaction in a batch reactor involving the hydrolysis of acetylated castor oil
Non-Isothermal Reactors
Figure 6-7. Conversion and temperature versus time.
473
474
Modeling of Chemical Kinetics and Reactor Design
Figure 6-8. Tubular (plug) flow reactor with heat transfer system.
To derive the enthalpy balance for a plug flow reactor, assume the following: • • • •
For plug flow, C ′A and T are constant at any cross-section. The coolant fluid temperature TC is constant. Steady-state condition (i.e., no accumulation in the system). Pressure drop over the reactor length is assumed to be very small (at constant density).
Consider the elemental volume Sδ1 at length 1 of the plug flow. Applying the general energy balance in differential form gives –Gδh + δQ = 0 From Equation 6-21
(6-31)
Non-Isothermal Reactors
δh = C pδT +
− ∆H R δm A a MA
and δQ = U • π • dt • δ1(TC – T)
475
(6-79) (6-80)
Substituting Equations 6-79 and 6-80 into Equation 6-31 yields − GC pδT − G
− ∆H R δm A + U • π • d t • δl(TC − T ) = 0 a MA
(6-81)
Dividing Equation 6-81 by δ1, as δ1 → 0 gives − GC p
− ∆H R 1 dm A dT − G + U • π • d t (TC − T ) = 0 dl a M A dl
(6-82)
A mass balance on A gives
−G
dC ′A = ( − rA ) S dl
It is known that C ′A = m A / M A ( mols / unit mass) If G/MA • dm A / dl is repalced by –(–rA)S, then GC p
dT − ∆H R + (− rA ) S + U • π • d t (T − TC ) = 0 dl a
(6-83)
FRACTIONAL CONVERSION XA FOR TUBULAR (PLUG) FLOW Beginning with –Gδh + δQ = 0, the energy balance equation in terms of the fractional conversion XA gives − ∆H R ∆m A − G C p ∆T + + U • π • d t (TC − T )δl = 0 a M A −ρuC p ∆T − ρu
− ∆H R ∆m A + U • π • d t (TC − T ) δl = 0 a MA
(6-84)
476
Modeling of Chemical Kinetics and Reactor Design
Equation 6-84 in terms of concentration gives
− ∆H R −ρuC p dT − u dC A + U • π • d t (TC − T ) δl = 0 a or ρuC p dT + u
− ∆H R dC A = U • d t A(TC − T ) a
Fractional conversion XA = (CAO – CA)/CAO and –CAOdXA = dCA. Hence, ρuC p dT − u C AO
− ∆H R dX A = U • d t A(TC − T ) a
(6-85)
ADIABATIC TUBULAR (PLUG) FLOW REACTOR Adiabatic plug flow reactors operate under the condition that there is no heat input to the reactor (i.e., Q = 0). The heat released in the reaction is retained in the reaction mixture so that the temperature rise along the reactor parallels the extent of the conversion. Adiabatic operation is important in heterogeneous tubular reactors. The equation –G∆h + Q = 0, where − ∆H R ∆m A ∆h = C p ∆T + gives a M A
− ∆H R ∆m A − G C p ∆T + = 0 a M A
(6-86)
or −ρuC p ∆T − u
− ∆H R ∆C A = 0 a
where C ′A = m A / M A and C A = ρ • C ′A . Rearranging and integrating Equation 6-86 between the boundary conditions of the tubular reactor, that is 1 = 0, CA = CAO, T = TO and 1 = L, CA = CA, T = T, gives
Non-Isothermal Reactors
−ρuC p (T − TO ) = u
477
− ∆H R (C A − C AO ) a
1 − ∆H R or T − TO = (C AO − C A ) ρC p a
(6-87)
In terms of the fractional conversion XA, 1 − ∆H R T − TO = C AO X A ρC p a or 1 − ∆H R 1 − ∆H R T − TO = C AO − C A )= C AO X A ( ρC p a ρC p a
(6-88)
AUTOTHERMAL REACTORS If a reaction requires a high temperature before proceeding at a normal rate, the products of the reaction will leave the reactor at a high temperature. The heat recovered can be used and the heat of reaction can be used to preheat the feed. There are several methods of achieving this type of operation in a reactor. An external heat exchanger can be employed to transfer the heat of reaction from the effluent to the feeds. Alternatively, the exchanger can be used as an integral part of the reactor or part of the high temperature effluent can be recycled. These processes involving heat transfer and reaction systems are referred to as autothermal. The essential feature of an autothermal reactor system is the feedback of reaction heat that is employed to raise the temperature and, therefore, the reaction rate of the incoming reactant stream. Its advantage is the self-sufficiency in energy even though high temperature is required for the reaction to commence. Another feature of the autothermal system is that an external heat source is required during the startup period while the system is working toward thermal equilibrium. The operation mode for these configurations is adiabatical or with heat transfer to the surrounding. Figures 6-9, 6-10, and 6-11, respectively, show different arrangements of an autothermal reactor
478
Modeling of Chemical Kinetics and Reactor Design
Figure 6-9. An autothermal reactor with an external heat exchanger.
CONVERSION IN AMMONIA SYNTHESIS In reviewing thermodynamics, the nature of the heat of reaction and whether the reaction is reversible can be investigated. In the synthesis of ammonia, reactors operate at about 200 atm and 350oC and approach the equilibrium conversion of about 70% in each pass. k1
N 2 + 3H 2 [ 2 NH 3 k2
The ammonia is separated from unreacted H2 and N2, and these are recycled back to the reactor. The overall process of a tubular reactor plus separation and recycle produces essentially 100% NH3 conversion.
Non-Isothermal Reactors
479
Figure 6-10. An autothermal multi-tubular reactor with an internal heat exchanger.
Water-gas shift:
CO + H 2 O [ CO 2 + H 2 k1
Ammonia synthesis: N 2 + 3H 2 [ 2 NH 3 k2
In ammonia synthesis, high temperatures correspond to small reactor volumes. For exothermic reactions, the equilibrium conversion Xe decreases as the temperature increases. Therefore, these reactions are often carried out in a series of adiabatic beds with either intermediate heat exchangers to cool the gases or bypass the cold feed to decrease the temperatures between the beds. Some compromise can be achieved between high temperatures involving small reactor volumes and high equilibrium conversions. The equilibrium constant Keq for ammonia synthesis is expressed as a function of the partial pressure as
480
Modeling of Chemical Kinetics and Reactor Design
Figure 6-11. An autothermal reactor with a recycle arrangement.
Non-Isothermal Reactors
K eq =
481
p 2NH 3 p N 2 • p 3H 2
Since the partial pressure is the mole fraction in the vapor phase multiplied by the total pressure, (i.e., pi = yi • P), the equilibrium constant Keq is expressed as Keq = Ky • P∆n, where ∆n = (2 – 1 – 3), the difference between the gaseous moles of the products and the reactants in the ammonia synthesis reaction. K eq =
where yi pi P R T ∆GoR
p 2NH 3 p N 2 • p 3H 2
= = = = = =
=
y 2NH 3 y N 2 y 3H 2
•
∆G oR 1 = exp − RT P2
mole fraction in the vapor phase of component i partial pressure of component i total pressure gas constant (1.987 cal/gmol•K, 8.314 J/mol•K) absolute temperature, K standard Gibbs free energy
The equilibrium constant Keq can be determined at any temperature from standard state information on reactants and product. Considering the synthesis of NH3, the equilibrium conversion Xe can be determined for a stoichiometric feed of H2 and N2, at the total pressure. These conversions are determined by the number of moles of each species against conversion X by taking as a basis, 1 mole of N2. Component
Number of moles Ni
Mole fraction yi
N2
1 – X
1− X 1− X = 4 − 2 X 2( 2 − X )
H2
3(1 – X)
3(1 − X ) 3(1 − X ) = 4 − 2 X 2( 2 − X )
NH3
2X
2X 2X = 4 − 2 X 2( 2 − X )
Total
∑Ni = 4 – 2X
∑yi = 1.0
Substituting the expressions for the mole fractions of H2, N2, and NH3, respectively, for the equilibrium constant Keq gives
482
Modeling of Chemical Kinetics and Reactor Design 2
K eq =
K eq =
p 2NH 3 p N 2 • p 3H 2
=
y 2NH 3 y N 2 y 3H 2
16 X 2 (2 − X )
2X 2 P 2( 2 − X ) 1 • 2 = 3 P (1 − X ) 3(1 − X ) 3 P P 2( 2 − X ) 2( 2 − X )
2
27(1 − X ) P 2 4
Table 6-5 shows the equilibrium constant Keq with the equilibrium partial pressure of NH3 starting with a stoichiometric mixture of H2 and N2 at pressures of 1, 10, and 100 atm. Figure 6-12 shows the relationship between equilibrium conversion Xe versus temperature and pressure for stoichiometric feed. Table 6-5 shows the conditions for which NH3 production is possible. Both low temperatures or very high pressures achieve favorable equilibrium. At 25°C, the equilibrium constant is very high, while at higher temperatures, both Keq and PNH3 decrease rapidly. Generally, ammonia synthesis reactors operate at about 350°C and 200 atm with an equilibrium conversion of about 70% in each pass. The NH3 is separated from unreacted H2 and N2, which are recycled back to the reactor. For the overall process involving the tubular reactor, separation and recycle produce about 100% ammonia conversion.
Table 6-5 Equilibrium constant and equilibrium PNH3 versus T and P T °C
Keq
25 100 200 300 400 500
5.27 × 10 0.275 × 103 0.382 0.452 × 10–2 0.182 × 10–3 0.160 × 10–4 5
1 atm
PNH3 10 atm
100 atm
0.937 0.660 0.172 0.031 0.00781 0.00271
9.80 8.76 5.37 2.07 0.682 0.259
99.3 95.9 81.9 58.0 34.1 18.2
Source: Schmidt, L. D, The Engineering of Chemical Reactions, New York, Oxford University Press, 1998.
Non-Isothermal Reactors
483
Figure 6-12. Profiles of equilibrium conversion Xe versus temperature T for ammonia synthesis. (Source: Schmidt, L. D., The Engineering of Chemical Reactions, Oxford University Press, New York, 1998.)
Example 6-8
A tubular reactor is to be designed for the synthesis of methanol from a stoichiometric mixture of CO and H2. The reaction occurs in the vapor phase using a solid catalyst in the form of porous spheres: CO + 2H2 = CH3OH. The average mixture physical and thermodynamic data at 500 K and 10 Mpa are Density Viscosity Heat of reaction Equilibrium constant Feed
Catalyst
30 kg/m3 2 × 10–5 Pa • s –100 kJ/mol CH3OH 0.3 × 104 Stoichiometric mixture at 473 K and 10 Mpa, gas velocity at reactor entrance is 0.15 m/sec = Porous spheres 3 mm in diameter, packed in tubes 40 mm internal diameter
= = = = =
Comment, from the reactor design and operation viewpoint, on the data.
484
Modeling of Chemical Kinetics and Reactor Design
Solution k1 kJ CO + 2 H 2 [ CH 3OH ∆H R = −100 k2 mol • CH 3OH
The reaction is reversible and strongly exothermic. The equilibrium yield of CH3OH decreases as the temperature increases. Hence, a low temperature and increased pressure will be kept.
The equilibrium constant Keq is expressed as K eq =
p CH 3OH k1 = k 2 p CO • p 2H 2
Since the partial pressure is the mole fraction in the vapor phase multiplied by the total pressure (i.e., pi = yiP), the equilibrium constant Keq is expressed as Keq = K y • P∆n, where ∆n = (1 – 1 – 2), the difference between the gaseous moles of the products and the reactants as in the ammonia synthesis reaction.
K eq =
p CH 3OH p CO • p 2H 2
=
y CH 3OH y CO y 2H 2
•
∆G OR 1 = exp − RT P2
The equilibrium constant Keq is determined at any temperature from standard state information on reactants and product. Considering the synthesis of CH3OH, the equilibrium conversion Xe is determined for a stoichiometric feed of CO and H 2 at the total pressure. These conversions are determined by the number of moles of each species against conversion X by taking as a basis, 1 mole of CO.
Non-Isothermal Reactors
485
Component
Number of moles Ni
Mole fraction yi
CO
1 – X
1− X 3 − 2X
H2
2(1 – X)
2(1 − X ) 3 − 2X
CH3OH
X
Total
∑Ni = 3 – 2X
X 3 − 2X ∑yi = 1.0
Substituting the expressions for the mole fractions of CO, H2, and CH3OH, respectively, for the equilibrium constant Keq yields
K eq =
K eq =
p CH 3OH p CO • p 2H 2 X (3 − 2 X )
=
y CH 3OH y CO y 2H 2
X P 1 3 − 2X • 2 = 2 P 1 − X P 2 − 2 X P 2 3 − 2X 3 − 2X
2
4 (1 − X ) P 2 3
Figure 6-13 shows plots of equilibrium conversion versus temperature. The plots indicate the conversion is low at operating temperature T = 473 K (200°C), but ensures rapid reaction. The conversion per pass is low, therefore, it is important to maintain a high pressure to achieve a high conversion. Modern methanol plants operate at about 250°C and 30–100 atm and give nearly equilibrium conversions using Cu/ZnO catalysts. The unreacted CO and H2 are recycled back into the reactor. Reynolds Number Assuming a reasonable approach to plug flow in the reactor, and assuming the Reynolds number of the fluid in the reactor is
Re p =
d pρv µ
where Rep = Reynolds number of the fluid in the reactor dP = catalyst diameter
486
Modeling of Chemical Kinetics and Reactor Design
Figure 6-12. Profiles of equilibrium conversion Xe versus temperature T for methanol synthesis. (Source: Schmidt, L. D., The Engineering of Chemical Reactions, Oxford University Press, New York, 1998.)
ρ = fluid density µ = fluid viscosity v = fluid velocity The Reynolds number Rep is Re p =
(3 × 10 −3 )(30)(0.15) m • kg • 2 × 10
−5
m
3
m m • sec • sec kg
= 675 The Reynolds number is 675, indicating that the fluid flow through the reactor is turbulent. Example 6-9 Design of Heterogeneous Catalytic Reactors
A bench-scale study of the hydrogenation of nitrobenzene was investigated by Wilson [2]. In this study, nitrobenzene and hydrogen were fed at a rate of 65.9 gmol/hr to a 30 cm internal diameter (ID) reactor containing the granular catalyst. A thermocouple sheath, 0.9
Non-Isothermal Reactors
487
cm in diameter, extended down the center of the tube. The void fraction was 0.424 and the pressure atmospheric. The feed entered the reactor at 427.5 K, and the tube was immersed in an oil batch maintained at the same temperature. The heat transfer coefficient from the mean reaction temperature to the oil bath was determined experimentally to be 8.67 cal/hr • cm2 • °C. A large excess of hydrogen was used so that the specific heat of the reaction mixture was equal to that of hydrogen. The change in total moles of the reaction was neglected, and the heat of reaction was approximately constant and equal to –152,100 cal/gmol. The feed concentration of nitrobenzene was 5 × 10–7 gmol/cm3. The global rate of reaction was represented by the expression
rp = 5.79 × 10 4 C 0.578 e
−
2, 958 T
where rP = gmol nitrobenzene reacting/cm3hr, expressed in terms of void volume in the reactor C = concentration of nitrobenzene, gmol/cm3 T = temperature, K Calculate the reactor temperature and conversion as a function of reactor length and comment on the results. Solution Concentration of nitrobenzene depends on both temperature and conversion. If u is the volumetric flowrate at a point in the reactor where the concentration is C, and uO is the value at the entrance, the conversion of nitrobenzene is
X=
u O C O − uC uC =1− uOCO uOCO
(6-89)
The volumetric flowrate depends on the temperature and changes as the temperature changes. Assuming a perfect gas behavior,
X =1−
CT C O TO
(6-90)
488
Modeling of Chemical Kinetics and Reactor Design
Rearranging Equation 6-90 in terms of concentration gives C=
C O TO (1 − X) T
(6-91)
427.5 = (5 × 10 −7 ) (1 − X) T
(6-92)
Substituting Equation 6-92 into the rate equation yields rp = 5.79 × 10 4 5 × 10 −7 × 1− X = 438 T
427.5 (1 − X) T
0.578 − 2, 958 e T
0.578 − 2, 958 e T
(6-93)
From the differential mass balance (Equation 5-321) in terms of the void volume,
FAO dX A = ( − rA′′′) dVp
(5-321)
The feed rate of nitrobenzene is
427.5 FA = 65.9 (22, 400) 5.0 × 10 −7 ) 273 ( = 1.16 gmol/hr Hence,
π 1.16 dX A = rp (0.424) (9 − 0.81) dl 4 1.16 dXA = 2.727(rP)dl
( )
dX A 2.727 = rp dl 1.16 =
2.727 1− X × 438 T 1.16
0.578 − 2, 958 e T
Non-Isothermal Reactors 0.578 − dX A 1− X = 1, 038 e T dl
2, 958 T
489
(6-94)
The energy balance for a tubular reactor is: ρuC p dT − u C AO
− ∆H R dX A = U πd t (TE − T )dl a
(6-95)
In terms of the heat transfer coefficient, hO,
ρuC p dT − u C AO or
− ∆H R dX A = h O πd t (TE − T )dl a
ρuC p dT = u C AO
− ∆H R dX A − h O πd t (T − TE )dl a
65.9 × 6.9dT = 1.16(152,00)dXA – 8.67(π)(3)(T – 427.5)dl ∆HR = –152,100 cal/gmol
dX dT = 385.48 A − 0.178(T − 427.5) dl dl
(6-96)
Substituting Equation 6-94 into Equation 6-96 gives 0.578 − 2, 958 dT 1− X = 385.481, 030 e T − 0.178(T − 427.5) dl T 0.578 − dT 1− X = 397, 044.4 e T dl
2, 958 T
− 0.178 (T − 427.5)
(6-97)
Equations 6-94 and 6-97 are first order differential equations, and it is possible to solve for both the conversion and temperature of hydrogenation of nitrobenzene relative to the reactor length of 25 cm. A computer program PLUG61 has been developed employing the Runge-Kutta fourth order method to determine the temperature and conversion using a catalyst bed step size of 0.5 cm. Table 6-6 shows
490
Modeling of Chemical Kinetics and Reactor Design
Table 6-6 Longitudinal temperature profile and conversion in a reactor for the hydrogenation of nitrobenzene
Non-Isothermal Reactors
491
the results of the program and Figure 6-14 illustrates the profile of the temperature against the catalyst-bed depth. The results show that as the bed depth increases, the mean bulk temperature steadily increases and reaches a maximum at about 13.0cm from the entrance to the reactor. This maximum temperature is referred to as the “hot spot” in
Figure 6-14. Conversion and temperature profiles for the hydrogenation of nitrobenzene.
492
Modeling of Chemical Kinetics and Reactor Design
the reactor. The conversion also increases and attains the maximum at about 24.0 cm from the entrance to the reactor. It is assumed that the radial temperature gradients in the plug flow reactor are negligible. Finally, these results are in agreement with the experimental results of Wilson, where the measured temperature was at the center of the reactor.
TWO-DIMENSIONAL TUBULAR (PLUG FLOW) REACTOR Consider a reaction A → products in a tubular reactor with heat exchanged between the reactor and the surroundings. If the reaction is exothermic and heat is removed at the walls, a radial temperature gradient occurs because the temperature at this point is greater than at any other radial position. Reactants are readily consumed at the center resulting in a steep transverse concentration gradient. The reactant diffuses toward the tube axis with a corresponding outward flow of the products. The concentration and radial temperature gradients in this system now make the one-dimensional tubular (plug flow) reactor inadequate. It is necessary to consider both the mass and energy balance equations for the two dimensions l and r. With reference to Figure 6-15, consider the effect of longitudinal dispersion and heat conduction. The following develops both material and energy balance equations for component A in an elementary annulus radius δr and length δl. It is also assumed that equimolecular counter diffusion occurs. Other assumptions are:
Figure 6-15. Differential section of two-dimensional tubular reactor.
Non-Isothermal Reactors
493
• Laminar flow • Constant dispersion and thermal conductivity coefficients • Instantaneous heat transfer between solid catalyst and the reacting ideal gas mixture • Neglect potential energy • The reaction rate is independent of total pressure The component mass balance of species A entering the element longitudinally and radially per unit time is Mass entering by longitudinal bulk flow = 2πrδrG(NA)l
(6-98)
Mass entering radially by diffusion
∂N = − D r 2πrδl A ∂r r
(6-99)
Mass entering by longitudinal diffusion ∂N = − D l 2πrδr A ∂l l
(6-100)
Mass leaving by longitudinal bulk flow ∂N A δl = 2πrδrG N A + l + δl ∂l
(6-101)
Mass leaving radially by diffusion ∂N ∂2 N A δr = − D r 2 πr( r + δr )δl A + r + δr ∂r ∂r 2
(6-102)
Mass leaving by longitudinal diffusion ∂N ∂2 N A δl = − D l 2 πrδr A + l + δl ∂l ∂l 2 Mass of component produced by chemical reaction = 2πrδrδlρb(–rA) where Dl = axial diffusivity Dr = radial diffusivity
(6-103)
(6-104)
494
Modeling of Chemical Kinetics and Reactor Design
In assuming a steady state, the algebraic sum of the components of mass entering (Equations 6-98, 6-99, and 6-100) and leaving (Equations 6-101, 6-102, 6-103, and 6-104) the element are zero. Expanding the terms evaluated at (l + δl) and (r + δr) in Taylor series about the points l and r, and neglecting the second order differences, gives
∂2 N ∂2 N A ∂N A 1 ∂N A D r 2A + −G = ρb ( − rA ) + Dl 2 r ∂r ∂l ∂l ∂r
(6-105)
The corresponding heat balance is − ∆H R ∂ 2 T 1 ∂T ∂2 T ∂T + kr 2 + − GC p k = ρb (− r ) l 2 a A ∂l r ∂r ∂l ∂r
(6-106)
where kl = axial thermal conductivity kr = radial thermal conductivity If the reaction rate is a function of pressure, then the momentum balance is considered along with the mass and energy balance equations. Both Equations 6-105 and 6-106 are coupled and highly nonlinear because of the effect of temperature on the reaction rate. Numerical methods of solution involving the use of finite difference are generally adopted. A review of the partial differential equation employing the finite difference method is illustrated in Appendix D. Figures 6-16 and 6-17, respectively, show typical profiles of an exothermic catalytic reaction. Figures 6-16 and 6-17, respectively, show the conversion is higher along the tube axis than at other radial positions and extremely high temperatures can be reached at the tube axis. These temperatures can be sufficiently high to damage the catalyst by overheating. A maximum temperature is also obtained along the reactor length, and the location of this hot spot can alter with changes in catalyst activity.
PRESSURE DROP (∆P) IN TUBULAR (PLUG FLOW) REACTORS It is important to determine pressure drop of fluid through tubular reactors, such as packed, fixed, and fluidized bed reactors where, catalysts are employed. ∆P is an important factor that influences the design and operation of such reactors. Ergun [3] developed a useful
Non-Isothermal Reactors
495
Figure 6-16. Conversion profiles as a function of tube length and radius.
∆P equation arising from simultaneous turbulent kinetic and viscous energy losses that is applicable to all flow types. Ergun’s equation relates the pressure drop per unit depth of packed bed to characteristics such as velocity, fluid density, viscosity, size, shape, surface of the granular solids, and void fraction. The original Ergun equation is: 1.75(1 − ε ) G v 150(1 − ε )2 µv ∆P • • 2 + gc = ε3 ε3 L Dp Dp
(6-107)
where ∆P = pressure drop lb/in.2, N/m2 L = unit depth of packed bed, ft, m gc = dimensional constant 32.174(lbm/lbf)(ft/sec2), lkg • m/N • sec2 µ = viscosity of fluid, lb/ft • hr, kg/m • sec v = superficial fluid velocity, ft/sec, m/sec Dp = effective particle diameter, ft, m G = superficial mass velocity, lb/hr • ft2, kg/m2s ε = void fraction of bed ρ = fluid density, lb/ft3, kg/m3
496
Modeling of Chemical Kinetics and Reactor Design
Figure 6-17. Temperature profiles as a function of tube length and radius.
Equation 6-107 gives the total energy loss in fixed beds as the sum of viscous energy loss (the first term on the right side of the equation) and the kinetic or turbulent energy loss (the second term on the right side of the equation). For gas systems, approximately 80% of the energy loss depends on turbulence and can be represented by the second term of Equation 6-107. In liquid systems, the viscous term is the major factor. For packed beds in either laminar or turbulent flow the Ergun equation is ρv 2 (1 − ε ) 150 (1 − ε ) µ dP 1.75 + =− s 3 dl D p ε D pρvs
(6-108)
where DP = diameter of the packing. For non-spherical packing, DP = 6(1 – ε)/φsS where S = So(1 – ε) and So = 6/Dpφs where So is the surface area per unit volume of solid material in the bed and φs = 1 for a spherical particle. Use six times the ratio of volume to surface area of the packing as an effective Dp.
Non-Isothermal Reactors
497
vs = superficial velocity when the tube is empty ρ = fluid density φs = shape factor of the solid, defined as the quotient of the area of a sphere equivalent to the volume of the particle divided by the actual surface of the particle µ = fluid viscosity Equation 6-108 can be expressed in the form −
ρvs2 dP =f dl gcD p
(6-109)
where the friction factor f is f =
b(1 − ε ) 1− ε a+ 3 ε Re
(6-110)
with a = 1.75, b = 150, and Re = ρvsDp/µ Hanley and Heggs [4] derived a value with a = 1.24 and b = 368. McDonald et al. [5] proposed that a = 1.8 for smooth particles and 4.0 for rough particles and b = 180. Hicks [6] reviewed various ∆P equations and inferred that the Ergun equation is limited to Re/(1 – ε) < 500 and Handley and Hegg’s equation to 1,000 < Re/(1 – ε) < 5,000. He developed an equation for the friction factor for spheres, which is of the form f =
6.8(1 − ε )1.2 • Re −0.2 ε3
(6-111)
which fits Ergun’s and Handley and Hegg’s data together with the results of Wentz and Thodos [7] at high Reynolds number. This shows that a and b are not true constants as stated by Tallmadge [8], who suggested that a = 1.75 and b = 4.2 Re5/6. Equation 6-108 is also a good approximation for a fluidized bed reactor up to the minimum fluidizing condition. However, beyond this range, fluid dynamic factors are more complex than for the packed bed reactor. Among the parameters that influence the ∆P in a fluidized bed reactor are the different types of two-phase flow, smooth fluidization, slugging or channeling, the particle size distribution, and the
498
Modeling of Chemical Kinetics and Reactor Design
gas flowrate. After reaching a peak ∆P at the point of minimum fluidization, the ∆P of a smoothly fluidizing bed drops to a value that approximately corresponds to the static pressure of the bed and remains nearly constant with an increase in the gas flowrate until the entrainment point is reached. A slugging bed displays a wide fluctuation in the ∆P beyond the point of minimum fluidization and a channeling bed exhibits a ∆P far below the bed static pressure. Figure 6-18 shows the behavior of fluidized beds in these three operation modes. ∆P for laminar flow in a circular tube is given by the HagenPoiseuille equation: dP vµ = −8 dl R
(6-112)
For turbulent flow, ∆P is calculated from dP 1 ρv 2 = − 4 fF dl D 2 or
ρv 2 dP = − fF R dl
(6-113)
Figure 6-18. Relationship between ∆P and gas linear velocity.
Non-Isothermal Reactors
499
or where the Darcy friction factor is four times the Fanning friction factor (i.e., fD = 4fF) ρV 2 dP = − fD 4R dl
(6-114)
The Fanning friction factor is given by fF = 0.079 Re–0.25 and the Reynolds number is Re = ρvDp/6µ(1 – ε) for a packed bed consisting of spherical particles and Re = ρvDpφs/6µ(1 – ε) for nonspherical particles. The values of φs for other materials are provided by Perry [9] and listed in the spreadsheet (PACKED.xls) package. Industrial design problems often occur in tubular reactors that involve the simultaneous solution of ∆P, energy, and mass balances. Example 6-10
A bed with a height 2.5 m and an internal diameter of 0.035 m is packed with cylindrical particles of diameter DP = 0.003 m. The void fraction of the bed is ε = .33. A gas of density ρ = 0.9487 kg/m3 and dynamic viscosity µ = 3.1 × 10–5 Pa • s flows through the bed with a superficial mass flow velocity of 1.4 kg/m2s. Determine the pressure drop in the bed. Solution From Ergun’s Equation 6-107 −
ρvs2 dP =f dl gcD p
(6-109)
where the friction factor f is f=
1 − ε b(1 − ε ) a+ ε 3 Re
a = 1.75 and b = 150 vs =
1.4 kg m3 • 2 0.9487 m • sec kg
= 1.475 m/sec
(6-110)
500
Modeling of Chemical Kinetics and Reactor Design
The Reynolds number, Re Re =
ρvs D p µ
m 0.9487 × 1.475 × 0.003 kg m = • • kg m 3 sec 3.1 × 10 −5 m • sec = 135 The friction factor f from Equation 6-110 is f=
(1 − 0.33) 0.333
1.75 +
150(1 − 0.33) 135
f = 46.4 The pressure drop –∆Pt is
− ∆Pt = f
ρvs2 L N , gcD p m2
− ∆Pt = 46.4
0.9487 × 1.4752 × 2.5 = 79, 809 N m 2 = 0.798 bar 1 × 0.003
McDonald et al. equation: a = 1.8, b = 180, f = 50.2, and –∆Pt = 86,368 N/m2 = 0.864 bar. Hicks equation: f = 43.9 and –∆Pt = 75,509 N/m2 = 0.755 bar. Tallmadge equation: a = 1.75, b = 4.2 Re5/6, f = 55.76, and –∆Pt = 95,908 N/m2 = 0.959 bar. An Excel spreadsheet program (PACKED.xls) was developed to determine ∆Ps of packed beds with known parameters.
THERMAL BEHAVIORS IN FLOW SYSTEMS The effect of temperature on chemical reaction influences the nature and size of the reactor, and the selectivity of the reaction. Additionally, the temperature effects may primarily determine both the stability and
Non-Isothermal Reactors
501
controllability of the reactor. Interesting and important temperature effects can occur in continuous reactor systems (e.g., CFSTR and plug flow reactors) with exothermic reactions. The rate of heat generation increases as the rate of reaction increases, and the reaction rate usually increases with the temperature in accordance with Arrhenius law. In a CFSTR, it is necessary to perform a material and an energy balance on an element of the system to understand its behavior. Consider a first order, exothermic reaction (aA → products) in a CFSTR having a constant supply of new reagents, and maintained at a steady state temperature T that is uniform throughout the system volume. Assuming perfect mixing and no density change, the material balance equation based on reactants is expressed as uCAO = uCA + (–rA)VR, where (–rA) = kCA. Substituting the rate expression into the material balance equation gives uCAO = uCA + kVRCA and the concentration of A at any time will be
CA =
C AO 1 + kVR u
(5-163)
The energy balance equation is: –uρ∆h + Q = 0
(6-31)
where ∆h = C p∆T + (–∆HR/a)( ∆m A / M A ), neglecting the pressure effects on h and the heat transfer rate Q is Q = UA(Th – T) where A U Th T
= = = =
heat transfer area overall heat transfer coefficient temperature of the heating medium temperature of the fluid in the system
The energy balance from Equation 6-39 yields a heating system
− ∆H R −ρuC p (T − TO ) + (− r ) V + UA(Th − T) = 0 a A R
502
Modeling of Chemical Kinetics and Reactor Design
− ∆H R or (− r ) V = uρC p (T − TO ) − UA(Th − T) a A R
(6-115)
where the left side of Equation 6-115 is Qg and is expressed as Qg =
− ∆H R (− rA )VR a
(6-116)
that is, the rate at which heat will be generated due to the reaction. The right side of Equation 6-115 is Qr, referred to as the heat removed by flow and heat exchange: Qr = –(uρCpTO + UATh) + (uρCp + UA)T
(6-117)
Substituting the Arrhenius equation (k = koe–E/RT) into the material balance for the exit concentration of A gives CA =
C AO 1 + k o e − E RT
VR u
(6-118)
Also, for the first order reaction, A → products, the rate expression is (–rA) = kCA. Substituting the rate expression, the Arrhenius equation, and Equation 6-118 into Equation 6-116 yields −E
Qg =
− ∆H R • V • C • k e RT a R AO o 1 + k oe
−E RT
•
VR u
(6-119)
Assuming that the CFSTR is operating at steady state, the rate of heat generation must equal the rate of heat removal from the reactor. Plotting Qg as a function of T for fixed values of the other variables, an S-shaped curve is obtained as shown in Figure 6-19. At low values of T, the reaction rates are low and therefore little or no heat is generated. At high values of T, the reaction goes to completion and the entire exotherm is released. The right side of Equation 6-117 gives a linear expression in T as illustrated in Figure 6-20.
Non-Isothermal Reactors
Heat generated Qg
503
Exotherm for complete reaction
Reactor operating temperature T
Figure 6-19. Heat generated by reaction versus temperature in a CFSTR.
Heat absorbed Qr
Reactor operating temperature T
Figure 6-20. Heat absorbed by enthalpy change and loss to environment.
504
Modeling of Chemical Kinetics and Reactor Design
Superimposing Figures 6-19 and 6-20, respectively, possible points of equality in heat generation and heat absorption can be observed as in Figure 6-21. From the slope and intercept of the heat absorption line, it is possible to manipulate Equation 6-117 by changing operating variables such as u, TO, and T or design variables such as the dimensionless heat transfer group UA/ρuCp. It is also possible to alter the magnitude of the reaction exotherm by changing the inlet reactant concentrations. Any of these manipulations can be used to vary the number of locations of the possible steady states.
EXOTHERMIC REACTIONS IN CFSTRs Consider an exothermic irreversible reaction with first order kinetics in an adiabatic continuous flow stirred tank reactor. It is possible to determine the stable operating temperatures and conversions by combining both the mass and energy balance equations. For the mass balance equation at constant density and steady state condition,
Figure 6-21. Multiple steady states for exothermic reaction in a CFSTR.
Non-Isothermal Reactors
CA =
C AO (1 + kt )
505
(5-163)
The conversion X A =
C AO − C A C = 1− A C AO C AO
Hence, the conversion XA for the CFSTR becomes XA =
kt 1 + kt
In terms of the temperature, the Arrhenius equation k = ko exp(–E/RT), the conversion is expressed as XA =
k o te − E RT 1 + k o te
(6-120)
− E RT
The steady state energy balance for adiabatic operation is determined as follows: From –G∆h + Q = 0 where ∆h = C p ∆T +
− ∆H R ∆m A a MA
and with G = ρu and Q = 0 (adiabatic condition): −ρuC p (T − To ) − ρu
− ∆H R ∆m A =0 a MA
In terms of the concentration CA, where CA = ρ •
mA ∆m A and ∆C A = ρ • MA MA
the energy balance becomes
− ∆H R −ρuC p (T − To ) − u (C − C AO ) = 0 a A
506
Modeling of Chemical Kinetics and Reactor Design
− ∆H R or (C − C A ) = ρC p (T − To ) a AO Introducing the fractional conversion, XA yields CAO – CA = CAOXA and the energy balance becomes
− ∆H R C X = ρC T − T p( o) a AO A The fractional conversion XA is XA =
ρC p (T − To ) − ∆H R C AO a
(6-121)
Since the heat of reaction usually varies little with temperature, the conversion XA gives a linear relationship between T – To and conversion, and is represented by a straight line as shown in Figure 6-22. For a known reactor and kinetics, and at a given feed temperature To, the intersection of the energy balance line with the S-shaped mass
Figure 6-22. Temperature versus conversion for a first order irreversible reaction in an adiabatic continuous flow stirred tank reactor.
Non-Isothermal Reactors
507
balance curve indicates that solutions are possible at three points A, B, and C, as shown in Figure 6-22. If the initial temperature is below the temperature at point A, say T1, Figure 6-22 shows that the conversion required by the mass balance is greater than the conversion that corresponds to the energy balance. Therefore, the energy evolved will raise the temperature to T2 and the corresponding conversion X2. The temperature T2 is X2 from Equation 6-120. The reaction rate is too low to justify steady state operation at initial temperature between points A and B, and as such the reaction mixture cools to point A. Correspondingly, the initial temperature between B and C is similar to temperatures below point A. However, in this case, heating will occur until point C is reached. At temperatures above point C, cooling occurs until the temperature drops to C. Point B is unstable because with a small increase in temperature, the heat produced (rapidly rising mass balance curve) is greater than the heat consumed by the reacting mixture (energy balance curve). The excess heat produced will make the temperature rise until point C is reached. Similarly, if the temperature drops slightly below point B, it will continue to drop until point A is reached. Therefore, point B is referred to as the ignition point. If the mixture is raised above this temperature, then the reaction will be self-sustaining. The relative position of the mass balance curve and the energy balance line in Figure 6-22 depends on various parameters, namely, the chemical properties (ko, E, ∆HR) and physical properties (ρ, CP) of the system and the operating conditions ( t , CAO) in Equation 6-120 and 6-121, respectively. These properties and conditions make it possible to determine whether or not stable operating conditions are permissible and how many stable operating points exist. Figure 6-23 illustrates fractional conversion XA versus temperature T for reversible exothermic reactions. There is an optimum operating temperature for the given space time value where conversion is maximized. XA decreases when T is above or below this optimum and, thus, adequate control of heat removal is essential.
THERMAL BEHAVIOR OF A TUBULAR FLOW REACTOR In a tubular reactor system, the temperature rises along the reactor length for an exothermic reaction unless effective cooling is maintained. For multiple steady states to appear, it is necessary that a
508
Modeling of Chemical Kinetics and Reactor Design
Figure 6-23. Solution of mass and energy balances for reversible exothermic reaction. (Source: O. Levenspiel 3rd ed. Chemical Reaction Engineering, John Wiley and Sons, 1999.)
feedback mechanism be provided so that the heat generated at one section of the reactor can pass back to an earlier section. In the CFSTR, the mixing provides the feedback. In a tubular flow reactor, the feedback is provided if axial heat conduction is significant or if there is a transfer of heat from the product stream to the feed stream. Figure 6-9 shows a plan for providing autothermal operation in tubular flow with temperature profiles. If an appropriate thermal feedback mechanism is not provided, the reaction occurs at the lower stationary state where the reaction rate may be negligible. The reaction could be extinguished, if the temperature of the feed entering the reactor drops below some critical value due to fouling of the heat exchange surface. An important effect in the design of a tubular flow reactor is the development of a radial temperature gradient in a highly exothermic reaction with wall cooling. The temperatures near the tube axis are
Non-Isothermal Reactors
509
much higher than those near the tube wall. Consequently, the temperature has an important effect on the reactor design because of the sensitivity of the reaction rate to temperature. The actual reaction rate can be much higher than the reaction rate as calculated on the basis of a constant temperature across the tube. Example 6-11
Consider a first order adiabatic reaction in a CFSTR with the following characteristics: Feed temperature, To, K Initial concentration, CAO, gmol/l
298 2
Volumetric flowrate, u, l/sec
0.05
Volume of the reactor, VR, l
15
Specific heat capacity, CP, cal/gm – K Density of fluid, ρ, g/l Heat of reaction, (–∆HR/a), cal/gmol
1 1,000 60,000
The rate constant k is expressed as k = exp(15.32 – 7,550/T), sec–1. Determine the operating points for both the mass and heat balance equations. Solution The first order reaction is represented by (–rA) = kCA, and applying the mass balance Equation 6-120 and the heat balance Equation 6-121, respectively, gives the fractional conversion XA in terms of the mass balance equation:
XA =
kt 1 + kt
(6-120)
and for the heat balance equation: XA =
ρC p (T − To ) − ∆H R C AO a
(6-121)
510
Modeling of Chemical Kinetics and Reactor Design
The residence time t = VR/u = 15.0/0.05 = 300.0 secs (l • sec/l). The mass balance equation now becomes XA =
300 k 1 + 300 k
and the heat balance equation is: XA =
ρC p T − 298 T − To ) = ( − ∆H R 120 C AO a
The fractional conversions XA in terms of both the mass balance and heat balance equations were calculated at effluent temperatures of 300, 325, 350, 375, 400, 425, 450, and 475 K, respectively. A Microsoft Excel Spreadsheet (Example6-11.xls) was used to calculate the fractional conversions XA at varying temperature. Table 6-7 gives the results of the spreadsheet calculation and Figure 6-24 shows profiles of the conversions at varying effluent temperature. The figure shows that the steady state values are (XA, T) = (0.02,300), (0.5,362), and (0.95,410). The middle point is unstable and the last point is the most desirable because of the high conversion. Example 6-12
A second order reaction is performed adiabatically in a CFSTR. Use the data in Example 6-11 to plot both conversions for the mass and heat balance equations. The second order rate constant k is Table 6-7 Fractional conversions XA (mass and heat balances) at effluent temperatures Temperature (K)
XA (Mass)
XA (Heat)
300 325 350 375 400 425 450 475
0.016 0.099 0.366 0.709 0.896 0.963 0.986 0.994
0.017 0.225 0.433 0.642 0.850 1.058 1.267 1.475
Non-Isothermal Reactors
511
Figure 6-24. Fractional conversions (XA) versus effluent temperature T (K).
k = exp 20 −
l 9, 000 T mol • sec
Solution The material balance for a second order reaction for species A in a CFSTR is uCAO = uCA + (–rA)VR, where
(− rA ) = kC2A uC AO = uC A + kC 2A VR
512
Modeling of Chemical Kinetics and Reactor Design
Rearranging the above equation in a quadratic form gives ktC 2A + CA – CAO = 0, which is of the form ax2 + bx + c = 0. The root of the equation is x=
− b ± b 2 − 4ac 2a
For a second order reaction the outlet concentration CA is CA =
−1 + 1 + 4 ktC AO 2 kt
where t = VR/u −1 + 1 + 4 ktC AO CA = 2 ktC AO C AO The fractional conversion XA = (CAO – CAO)/CAO = 1 – CA/CAO. Since XA < 1, the smaller root is used, which is −1 + 1 + 4 ktC AO XA = 1 − 2 ktC AO
The fractional conversion XA in terms of the heat balance equation is: XA =
ρC p T − 298 T − To ) = ( − ∆H R 120 C AO a
The heat removal line is unchanged irrespective of the kinetics, and the fractional conversion XA has a qualitatively similar sigmoidal shape for second-order kinetics. Numerical values as in Example 6-11 have been put into both the mass balance and heat balance equations. Fractional conversion XA from both the mass balance and heat balance equations at effluent temperatures of 300, 325, 350, 375, 400, 425, 450, and 475 K, respectively, were determined using the Microsoft Excel Spreadsheet (Example6-12.xls). Table 6-8 gives the results of
Non-Isothermal Reactors
513
Table 6-8 Fractional conversions XA (mass and heat balances) at effluent temperatures Temperature (K)
XA (Mass)
XA (Heat)
300 325 350 375 400 425 450 475
0.026 0.183 0.498 0.740 0.867 0.929 0.960 0.976
0.017 0.225 0.433 0.642 0.850 1.058 1.267 1.475
the spreadsheet calculation and Figure 6-25 shows profiles of the conversion at varying effluent temperature. The steady states values in Figure 6-25 are (XA,T) = (0.02, 300), (0.32, 335), and (0.88, 405). The middle point is unstable and the last point is the most desirable because of the high conversion.
Figure 6-25. Fractional conversions (XA) versus effluent temperature T (K).
514
Modeling of Chemical Kinetics and Reactor Design
Example 6-13
Determine the operating conditions in a CFSTR for a first order exothermic reaction with heat transfer under the following conditions: Feed temperature, TO, K Initial concentration, CAO, gmol/l Temperature of the cooling medium, TC, K Mean residence time, t , min (–∆HR/a)(1/ρCp), K/gmol–l UA/uρCp Reaction rate constant, k, min–1
350 1 350 1 200 1 exp(25 – 10,000/T)
Solution The heat balance, –G∆h + Q = 0, gives −ρuC p (T − TO ) − ρu
− ∆H R ∆m A + UA(TC − T ) = 0 a MA
which gives − ∆H R −ρuC p (T − TO ) + (− r )V + UA(TC − T) = 0 a A R
For a first order reaction in a CFSTR, the rate expression (–rA) = kCA and the exit concentration CA is CA = CAO/(1 + kt ). The fractional conversion XA = (CAO – CA)/CAO = 1 – CA/CAO, and XA = kt /(1 + kt ). The heat balance equation in terms of the initial concentration of the feed becomes − ∆H R kC AO −ρuC p (T − TO ) + V + UA(TC − T ) = 0 a 1 + kt R
Rearranging in terms of heat generation Qg and heat removal Qr gives
− ∆H R kC AO VR = ρuC T − T + UA T − T ( C) p( O) a 1 + kt Further rearrangement in terms of the data in the table gives
Non-Isothermal Reactors
515
− ∆H R 1 kC AO t UA a • ρC 1 + kt = (T − TO ) + uρC (T − TC ) p p where the mean residence time t = VR/u. The heat generation Qg is − ∆H R 1 kC AO t Qg = • ρC p 1 + kt a and the heat removal Qr is Q r = (T − TO ) +
UA (T − TC ) uρC p
Substituting the values in the table for both Qg and Qr gives Qg =
(200)(1)(1) exp(25 − 10, 000 T) 1 + exp(25 − 10, 000 T )
and
Q r = (T − 350) + (1)(T − 350) = 2(T − 350) A Microsoft Excel Spreadsheet (Example6-13.xls) was used to determine both Qg and Qr at varying effluent temperature. Figure 6-26 shows the profiles of the heat generation and heat removal terms, and the intersections give the operating conditions. The values of the fractional conversion XA corresponding to the temperatures at these points are given in Table 6-9.
VARIABLE COOLANT TEMPERATURE IN A CFSTR Consider a jacketed CFSTR with an external jacket as shown in Figure 6-27 in which the coolant fluid temperature TC is not maintained constant. This situation requires solving an energy balance equation on the coolant along with the mass and energy balance
516
Modeling of Chemical Kinetics and Reactor Design
Figure 6-26. Heat of generation/removal versus effluent temperature T(K).
equations on the reactor. If the coolant fluid inlet and outlet temperatures are TCO and TC, respectively, the coolant volumetric flow rate is uC, and the contact area with the reactor is A, then the mass and energy balance equations for the jacketed CFSTR with a single reaction A → products become Mass balance: uCAO = uCA + (–rA)VR, which is CAO – CA = CAOXA = kt , where t = VR/u. The heat balance on the CFSTR is − ∆H R −ρuC p (T − TO ) + (− r )V + UA(TC − T ) = 0 a A R
and the heat balance on the coolant is –ρcucCpc(TC – TCO) + UA(T – TC) = 0
Non-Isothermal Reactors
517
Table 6-9 Qg and Qr at effluent temperature Temperature (K)
Qg
Qr
350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500
5.469 11.707 23.279 42.304 69.003 100.000 129.577 153.365 170.244 181.319 188.293 192.612 195.284 196.947 197.993 198.661
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300
Points of intersections between Qg and Q r Temperature (K)
Rate constant
Conversion XA
354 400 440
0.039 1.000 9.706
0.037 0.500 0.907
where Cpc uC TC TCO ρc
= = = = =
specific heat capacity of the coolant coolant volumetric flowrate coolant fluid temperature coolant fluid inlet temperature density of cooling fluid
The residence time of the coolant in the jacket is t C = VC/uC. Given the three simultaneous equations and with known parameters, it is now possible to solve for CA, T, and TC, respectively. The CFSTR is readily adaptable to both heating and cooling because the fluid can be stirred to promote heat transfer, ensuring better heat management with minimum heat transfer area. A combination of both jacket and internal coil may be necessary to provide the required heat exchange area. Chapter 7 reviews the heat transfer coefficient and the
518
Modeling of Chemical Kinetics and Reactor Design
Figure 6-27. A jacketed CFSTR.
time it takes for heating or cooling of process fluids in jacketed agitated vessels.
OPTIMAL DESIGN OF NON-ISOTHERMAL REACTORS In many cases, the design of reactors has appreciable significant heat changes. The accompanying temperature change affects the size of the reactors. Levenspiel [11,12] has shown that the optimum reactor size is determined by operating isothermally at the maximum allowable temperature. In the case of a reversible exothermic reaction, the ideal optimum reactor size is obtained by following the locus of the maximum rates known as the optimum temperature progression (OTP) on the rate-temperature conversion (r – T – XA) chart. Levenspiel has provided the (r – T – XA) chart for a reversible first order reaction A ↔ R. Omoleye et al. [13] have further provided the (r – T – XA) charts for the generalized types of reversible reactions, and developed mathematical expressions for the optimum temperature progression for these types of reactions at constant density. The following reviews the analytical treatment of (r – T – X A) charts and develops computer programs for this class of reversible reactions.
Non-Isothermal Reactors
519
THEORY AND DERIVATIONS FOR THE CONVERSION OF REVERSIBLE REACTIONS Most chemical reactions of industrial significance fall within the general class of reversible reactions given by Type 1: aA ↔ rR
(6-122)
Examples: polymerization, isomerization reactions Type 2: aA + bB ↔ rR
(6-123)
Examples: oxidation, hydrogenation, and halogenation reactions Type 3: aA + bB ↔ rR + sS
(6-124)
Examples: esterification, saponification, and neutralization reactions Type 4: aA ↔ rR + sS
(6-125)
Examples: decomposition, dehydrogenation, and sublimation reactions If k1 and k2 denote the forward and reverse rate constants respectively, the general rate of disappearance (–rA) for any type of reaction is defined as: M
(− rA ) = k1 ∏ Cαi i i =1
N
− k 2 ∏ Cβj i j =1
(6-126)
where Ci and Cj are the concentrations of reactant i and product j with orders αi and βj, respectively. The forward and reverse rate constants k1 and k2 have the Arrhenius form −E k1 = A1 exp 1 RT
(6-127)
and −E k 2 = A 2 exp 2 RT
(6-128)
520
Modeling of Chemical Kinetics and Reactor Design
For a constant density system, the concentration of any species, K, CK, during the course of reaction is given by CK = CAO (θK + υKXA)
(6-129)
where θK = feed concentration ratio of species K to that of A υK = stoichiometric coefficient ratio of species K to that of A; by convection, it is negative for reactants and positive for products
r −b Hence, υA = –1, υ R = , υ B = a a Type 1 Reaction: aA
k1
[ k
rR
2
The rate of disappearance of A may be written as
(− rA ) = k1CαA1 − k 2CβR1
(6-130)
where α1 and β1 are the orders of reaction with respect to species A and R, respectively. From stoichiometry:
At time t = 0 At time t = t Amount reacted
From conversion X A =
A
R
CAO CA CAO – CA
0 CR CR
C AO − C A C AO
(5-13)
CAOXA = CAO – CA
(5-27)
and CA = CAO (1 – XA)
(5-28)
The concentration of R is expressed by CR = CAOXA or CR = CAO (θR + υRXA)
(6-131)
Non-Isothermal Reactors
521
Substituting Equations 5-28 and 6-131 into Equation 6-130 gives
(− rA ) = k1CαAO1 (1 − X A )α1 − k 2CβAO1 (θ R + υ R X A )β1
(6-132)
Rearranging Equation 6-132 yields 1 k1C αAO (1 − X A )
α1
1 − k 2 CβAO (θ R + υ R X A )
β1
− ( − rA ) = 0
(6-133)
Equation 6-133 is of the form f(XA) = 0. It is possible to solve Equations 6-127, 6-128, and 6-133 simultaneously to give the temperature – conversion (T – XA) data for a specified value of (–rA) if the values for CAO, θR, α1, β1, and υR are known. Consider the first order rate of reaction with respect to both the reactants and products. That is, α1 = β1 = 1. Equation 6-133 becomes k1C AO (1 − X A ) − k 2 C AO (θ R + υ R X A ) − ( − rA ) = 0
(6-134)
Rearranging Equation 6-134 gives the fractional conversion XA as XA =
k1C AO − k 2 C AOθ R − ( − rA ) ( k1C AO + k 2C AO υ R )
(6-135)
k1 − k 2θ R − ( − rA ) C AO k1 + k 2 υ R
(6-136)
or X A =
Equation 6-136 is the basis for the r – T – XA chart as developed by Levenspiel [11]. Assuming that there is no product recycle (θR = 0) and that the reaction is unimolecular reversible reaction (υR = 1), Equation 6-136 becomes
XA =
k1 − ( − rA ) C AO k1 + k 2
(6-137)
For values of E1 = 11,600 cal/gmol, E2 = 29,600 cal/gmol, A1 = exp(17.2), A2 = exp(41.9), and CAO = 1 mol/l. It is possible to solve Equation 6-137 with Equations 6-127 and 6-128 simultaneously for
522
Modeling of Chemical Kinetics and Reactor Design
the temperature range of 260–400 K. A computer program was developed to determine the fractional conversion for different values of (–rA) and a temperature range from 260–400 K. Figure 6-28 shows the rate of reaction profile from the computer results. The plot shows the same profile given by Levenspiel [11]. Type 2 Reaction: aA + bB
k1
[ k
rR
2
The general kinetic rate of disappearance of A is:
(− rA ) = k1CαA1 CαB2 − k 2CβR1
(6-138)
Figure 6-28. Rate of reaction profile for a first order reversible reaction A ↔ R.
Non-Isothermal Reactors
523
From stoichiometry:
At time t = 0 At time t = t Amount reacted
A
B
R
CAO CA CAO – CA
CBO CB CBO – CB
0 CR CR
C AO − C A C BO − C B C R = = C AO C AO C AO
(6-139)
CBO – CB = CAOXA
(6-140)
Therefore,
C B = C BO − C AO X A C = C AO BO − X A C AO Hence, CB = CAO (θB – XA) or CB = CAO (θB + υBXA)
(6-141)
where υb is the stoichiometric coefficient ratio of species B to that of A, which equals –b/a. The fractional conversion XA is given by XA = (CAO – CA)/CAO and the concentration of A is expressed by CA = CAO (1– XA)
(5-28)
The concentration of R is expressed by CR = CAO (θR + υRXA)
(6-131)
Substituting Equations 5-28, 6-131, and 6-141 into Equation 6-138 gives
(− rA ) = k1CαAO1 (1 − X A )α1 CαAO2 (θB + υBX A )α 2 1 − k 2 CβAO (θ R + υ R X A )
β1
(6-142)
524
Modeling of Chemical Kinetics and Reactor Design
Rearranging Equation 6-142 gives 1 +α2 k1C αAO (1 − X A )
α1
(θ B + υ B X A ) α 2
1 − k 2 CβAO (θ R + υ R X A )
β1
− ( − rA ) = 0
(6-143)
Equation 6-143 represents the r – T – XA profile equation if α1 = α2 = β1 = 1 and –υA = –υB = υR = 1. For a product-free feed (θR = 0) containing equimolecular concentrations of reactant A and B (θB = 1), Equation 6-143 becomes k1C 2AO (1 − X A ) − k 2 C AO X A − ( − rA ) = 0 2
(6-144)
Equation 6-144 is further expressed to give k1C 2AO X 2A − ( k 2 C AO + 2 k1C 2AO )X A + k1C 2AO − ( − rA ) = 0
(6-145)
Equation 6-145 is a quadratic equation and the fractional conversion XA is given by
(k 2C AO + 2 k1C2AO ) XA =
{
[
]}
± ( k 2 C AO + 2 k1C 2AO ) − 4 k1C 2AO k1C 2AO − ( − rA ) 2
2 k1C 2AO
0.5
(6-146)
Using the values of CAO = 0.1 mol/l, A1, A2, E1, and E2 as given in Type 1 reaction, it is possible to solve Equation 6-146 with Equations 6-127 and 6-128 simultaneously for the temperature range of 260–400 K. A computer program was developed to determine the fractional conversion for different values of (–rA) over the temperature range of 260–400 K. Figure 6-29 shows the reaction profile of the computer results. Type 3 Reaction: aA + bB
k1
[ k
rR + sS
2
The net rate of disappearance of A is
Non-Isothermal Reactors
525
Figure 6-29. Rate of reaction profile for reaction type A + B ↔ R.
(− rA ) = k1CαA1 CαB2 − k 2CβR1 CβS2
(6-147)
From stoichiometry:
At time t = 0 At time t = t Amount reacted
A
B
R
S
CAO CA CAO – CA
CBO CB CBO – CB
0 CR CR
0 CS CS
Diving by the initial concentration of A gives
526
Modeling of Chemical Kinetics and Reactor Design
C AO − C A C BO − C B C R C = = = S C AO C AO C AO C AO
(6-148)
CA = CAO(1–XA)
(5-28)
CR = CAO(θR + υRXA)
(6-131)
CB = CAO(θB + υBXA)
(6-141)
CS = CAOXA or C S = C AO (θS + υS X A )
(6-149)
Substituting Equations 5-28, 6-131, 6-141, and 6-149 into Equation 6-147 yields
(− rA ) = k1 CαAO1 (1 − X A )α1 CαAO2 (θB + υBX A )α 2 1 − k 2 CβAO (θ R + υ R X A ) 1 CβAO2 (θS + υSX A )
β
β2
(6-150)
Rearranging Equation 6-150 with α1 = α2 = β1 = β2 = 1 gives k1C 2AO (1 − X A )(θ B + υ BX A ) − k 2 C 2AO (θ R + υ R X A )(θS + υS X A ) − ( − rA ) = 0
(6-151)
If the feed contains equimolar concentrations of reactants A and B, then θB = 1. If –υA = –υB = υR = υS = 1, and there is no product recycle (θR = θS = 0), Equation 6-151 becomes k1C 2AO (1 − X A ) − k 2 C 2AO X 2A − ( − rA ) = 0 2
(6-152)
Further expansion and rearrangement of Equation 6-152 gives
k1C 2AO − 2 k1C 2AO X A + k1C 2AO X 2A − k 2 C 2AO X 2A − ( − rA ) = 0
(6-153)
Equation 6-153 can be expressed in the form of a quadratic equation in terms of the fractional conversion XA as
Non-Isothermal Reactors
(− r ) ( k1 − k 2 )X 2A − 2 k1X A + k1 − C2A = 0
527
(6-154)
AO
The fractional conversion XA from Equation 6-154 becomes
XA =
{
[
2 k1 ± 4 k12 − 4( k1 − k 2 ) k1 − ( − rA ) C 2AO 2( k 1 − k 2 )
]}
0.5
(6-155)
Using the same values of the kinetic parameters as in Type 1, and given CAO = 0.1 mol/l, it is possible to solve Equation 6-155 with Equations 6-127 and 6-128 simultaneously to determine the fractional conversion XA. A computer program was developed to determine the fractional conversion for different values of (–rA) and a temperature range of 260–500 K. Figure 6-30 shows the reaction profile from the computer results. If k1 = k2 = 1 (i.e., the equilibrium constant is unity), the value of X A in Equation 6-155 becomes infinite and the equation is inapplicable. However, the value of XA in Equation 6-154 becomes
−2 k1X A + k1 −
and X A =
or X A =
(− rA ) = 0
(6-156)
C 2AO
k1 − ( − rA ) C 2AO 2 k1
1 − ( − rA ) k1C 2AO 2
(6-157)
(6-158)
The corresponding r – T – XA data can be determined from Equation 6-158. Type 4 Reaction: aA
k1
[ k
rR + sS
2
The net rate of disappearance for this case is:
(− rA ) = k1CαA1 − k 2CβR1 CβS2
(6-159)
528
Modeling of Chemical Kinetics and Reactor Design
Figure 6-30. Rate of reaction profile for reaction type A + B ↔ R + S.
From stoichiometry:
At time t = 0 At time t = t Amount reacted
CA – CAO (1 –XA)
A
R
S
CAO CA CAO – CA
0 CR CR
0 CS CS
(5-28)
CR = CAO (θR + υRXA)
(6-131)
CS = CAO (θS + υSXA)
(6-149)
Non-Isothermal Reactors
529
Substituting Equations 5-28, 6-131, and 6-149 into Equation 6-159 gives
(− rA ) = k1CαAO1 (1 − X A )α1 1 − k 2 CβAO (θ R + υ R X A ) 1 CβAO2 (θS + υSX A )
β2
β
(6-160)
Rearranging Equation 6-160 with α1 = β1 = β2 = 1 gives k1C AO (1 − X A ) − k 2 C 2AO (θ R + υ R X A )(θS + υS X A ) − ( − rA ) = 0
(6-161)
Again, if the feed contains equimolar concentrations of pure A, with –υA = υR = υS = 1, and there is no product recycle (θR = θS = 0), Equation 6-161 becomes
k1C AO (1 − X A ) − k 2 C 2AO X 2A − ( − rA ) = 0
(6-162)
or k 2 C 2AO X 2A + k1C AO X A − k1C AO + ( − rA ) = 0
(6-163)
Equation 6-163 is a quadratic equation in terms of the fractional conversion XA. The roots of XA become
XA =
{
]}
[
− k1C AO ± ( k1C AO ) − 4 k 2 C 2AO − k1C AO + ( − rA ) 2
0.5
2 k 2 C 2AO
(6-164)
or
XA =
{
[
]}
− k1C AO ± ( k1C AO ) + 4 k 2 C 2AO k1C AO − ( − rA ) 2
2 k 2 C 2AO
0.5
(6-165)
Using the same values of the kinetic parameters as in Type 3, with CAO = 1 mol/l and solving Equations 6-165, 6-127, and 6-128 simultaneously, it is possible to determine the fractional conversion XA. A computer program was developed to determine the fractional conversion for different values of (–rA) and a temperature range of 260–500 K. Figure 6-31 illustrates the reaction profile.
530
Modeling of Chemical Kinetics and Reactor Design
Figure 6-31. Rate of reaction profile for reaction type A ↔ R + S.
OPTIMUM TEMPERATURE PROGRESSION Following the path of the locus of the maximum rates, referred to as the optimum temperature progression (OTP), determines the ideal optimum reactor size for an exothermic reaction (Figures 6-28, 6-29, 6-30, and 6-31). It can also establish a functional relationship between the optimum temperature, Topt, and the conversion XA for any type of reaction and kinetics by developing a computer program. This alleviates the cumbersome graphical reactor design [11,12], and the mathematical relation can be incorporated into the reactor design equations.
Non-Isothermal Reactors
531
The following derives equations for the optimum temperature progression for the four types of reactions previously described at constant density. Figures 6-28, 6-29, 6-30, and 6-31 show that the r – T – XA profile for an exothermic reaction is unimodal. Therefore, the optimum temperature Topt is obtained by performing a partial differentiation of (–rA) with respect to temperature T at a constant conversion XA and equating this to zero. That is, ∂( − rA ) =0 ∂T X
(6-166)
A
Therefore, using the general kinetic Equation 6-126 gives ∂( − rA ) ∂k1 M α i ∂k 2 = ∏ C i − ∂T ∂T X A ∂T i =1
N
βj
∏Cj
=0
j =1
(6-167)
Both Ci and Cj are only functions of XA where −E k1 = A1 exp 1 RT
(6-127)
−E and k 2 = A 2 exp 2 RT
(6-128)
Differentiating k1 with respect to T in Equation 6-127 gives ∂k1 A1E1 exp( − E1 RT ) = ∂T RT 2
(6-168)
and differentiating k2 with respect to T in Equation 6-128 gives
∂k 2 A 2 E 2 exp( − E 2 RT ) = ∂T RT 2
(6-169)
Substituting Equations 6-168 and 6-169 into Equation 6-167 gives
532
Modeling of Chemical Kinetics and Reactor Design
M ∂( − rA ) A1E1 − E1 exp C αi i = ∏ 2 RT i =1 ∂T X A RT
−
N A2E2 β −E2 exp C j j = 0 at T = Topt ∏ 2 RT j =1 RT
(6-170)
Consider the solution of Equation 6-170 for each of the four types of rate expressions to determine the optimum temperature progression at any given fractional conversion XA. Type 1 Reaction: aA
k1
[ k
rR
2
The net rate of disappearance of A is
(− rA ) = k1CαA1 − k 2CβR1
(6-130)
Substituting Equation 6-130 into Equation 6-170 yields
∂( − rA ) A1E1 −E exp 1 C αA1 = 2 RT ∂T X A RT −
−E A2E2 exp 2 CβR1 = 0 at T = Topt RT RT 2
(6-171)
where CA = CAO (1 – XA) CR = CAO (θR + υRXA)
(5-28) (6-131)
Substituting Equations 6-28 and 6-131 into Equation 6-171 yields −E A1E1 α 1 exp 1 C αAO 1 − XA ) 1 ( 2 RT RT −
−E A2E2 1 exp 2 CβAO (θ R + υ R X A )β1 = 0 2 RT RT
(6-172)
Non-Isothermal Reactors
533
Rearrangement of Equation 6-172 gives
E E α β 1 1 A1E1 exp 2 − 1 C αAO 1 − X A ) 1 = A 2 E 2 CβAO θR + υR X A ) 1 ( ( RT RT and the optimum temperature progression Topt is
Topt =
E 2 − E1 β A E C 1 − α1 θ R 2 2 AO
R ln
(
+ υR X A
A1E1 (1 − X A )
α1
)
β1
(6-173)
Equation 6-173 suggests that for every value of X A, there is a corresponding temperature Topt on the optimum temperature progression OTP. k1 Consider a first order reversible reaction A [ R, where the rate k expression is (–rA) = k1CA – k2CR. Therefore, α12 = β1 = υR = 1. For a feed concentration, CAO = 1.0 mol/l with no product (θR = 0), using XA = 0.485 with the following kinetic parameters gives E1 E2 R A1 A2
= = = = =
11,600 cal/mol 29,600 cal/mol 1.987 cal/mol • K exp(17.2) exp(41.9)
The optimum temperature progression Topt is Topt =
Topt =
E 2 − E1 A2E2XA R ln A1E1 (1 − X A )
(29, 600 − 11, 600)
exp( 41.9)(29, 600)(0.485) 1.987 ln exp(17.2)(11, 600)(0.515)
= 354.18 K
(6-174)
534
Modeling of Chemical Kinetics and Reactor Design
This agrees with the value of 354 K at XA = 0.485 obtained from geometrical construction of the optimum temperature progression given by Levenspiel [11]. A Microsoft Excel Spreadsheet (OPTIMUM61.xls) was used to determine the optimum temperature progression (Topt) for varying values of fractional conversion (XA). Table 6-10 gives the results of the spreadsheet calculation, and Figure 6-32 shows that the optimum temperature progression decreases with increasing fractional conversion.
Table 6-10 Optimum temperature progression for a first order reversible reaction A ↔ R Kinetic parameters E1 E2 R A1 A2 CAO
11,600 29,600 1.987 17.2 41.9 1
Conv. XA
Temp (K)
0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.485 0.5 0.55 0.6 0.65 0.7 0.75 0.8 0.85 0.9 0.95 0.99
386.5 378.0 373.6 369.2 365.4 362.1 359.0 356.1 354.2 353.4 350.6 347.9 345.0 342.1 338.8 335.2 331.0 325.5 317.0 299.6
Non-Isothermal Reactors
535
Figure 6-32. Fractional conversion XA versus Topt for a first order reversible reaction A ↔ R.
Type 2 Reaction: aA + bB
k1
[ k
rR
2
The rate expression is
(− rA ) = k1CαA1 CαB2 − k 2CβR1
(6-138)
with CA = CAO(1 – XA)
(5-28)
CR = CAO(θR + υRXA)
(6-131)
CB = CAO(θB + υBXA)
(6-141)
Substituting Equations 5-28, 6-131, and 6-141 into Equation 6-138 gives
536
Modeling of Chemical Kinetics and Reactor Design
(− rA ) = k1CαAO1 (1 − X A )α1 CαAO2 (θB + υBX A )α 2 1 − k 2 CβAO (θ R + υ R X A
)β1
(6-175)
when [∂(–rA)/∂T]XA = 0, then
∂( − rA ) −E A1E1 α α 1 +α2 exp 1 C αAO θ B + υ BX A ) 2 (1 − X A ) 1 ( = 2 RT ∂T X A RT
−
A2E2 −E β 1 exp 2 CβAO θR + υR X A ) 1 = 0 ( 2 RT RT
(6-176)
Rearranging Equation 6-176 gives −E A1E1 α α 1 +α2 exp 1 C αAO θ B + υ BX A ) 2 (1 − X A ) 1 ( 2 RT RT =
−E A2E2 1 exp 2 CβAO (θ R + υ R X A )β1 RT RT 2
(6-177)
The optimum temperature progression at T = Topt from Equation 6-177 is Topt =
E 2 − E1 A E Cβ1 − (α1 + α 2 ) (θ + υ X )β1 R R A R ln 2 2 AO α1 α2 A1E1 (1 − X A ) (θ B + υ BX A )
(6-178)
k1
For a reaction A + B k[ R, whose kinetics is first order with re2 spect to the reactants A and B (that is, α1 = α2 = 1), and the product R (i.e., β1 = 1) occurs in a reactor fed with pure equimolar reactant concentration, then θB = 1, θR = 0, υR = –υB = 1. Putting these values into Equation 6-178 yields Topt =
E 2 − E1
A E C −1 X R ln 2 2 AO A2 A1E1 (1 − X A )
(6-179)
Non-Isothermal Reactors
537
Using the kinetic parameters in Type 1 reaction at XA = 0.5, the optimum temperature progression Topt is
Topt =
(29, 600 − 11, 600)
(e 24.7 ) (29, 600) (0.5) 1.987 ln 2 (11, 600)(0.5 )
= 344.05 K The Microsoft Excel Spreadsheet (OPTIMUM62.xls) was used to determine Topt for varying values of XA (0.1 < XA < 0.99). Table 6-11 gives the results of the spreadsheet calculation, and Figure 6-33 shows the profile of Topt against XA. Figure 6-33 gives the same profile as Type 1. Type 3 Reaction: aA + bB
k1
[ k
rR + sS
2
The rate expression is
(− rA ) = k1CαA1 CαB2 − k 2CβR1 CβS2
(6-147)
with CA = CAO(1 – XA)
(5-28)
CR = CAO(θR + υRXA)
(6-131)
CB = CAO(θB + υBXA)
(6-141)
CS = CAO(θS + υSXA)
(6-149)
Substituting Equations 5-28, 6-131, 6-141, and 6-149 into Equation 6-147 gives
(− rA ) = k1CαAO1 (1 − X A )α1 CαAO2 (θB + υBX A )α 2 1 − k 2 CβAO (θ R + υ R X A ) 1 CβAO2 (θS + υSX A )
β
β2
At [∂(–rA)/∂T]XA = 0, Equation 6-180 becomes
(6-180)
538
Modeling of Chemical Kinetics and Reactor Design
Table 6-11 Optimum temperature progression for reaction type A + B ↔ R Kinetic parameters E1 E2 R A1 A2 CAO
11,600 29,600 1.987 17.2 41.9 1
Conv. XA
Temp (K)
0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.485 0.5 0.55 0.6 0.65 0.7 0.75 0.8 0.85 0.9 0.95 0.99
384.7 376.4 370.1 364.9 360.2 356.0 351.9 348.0 345.2 344.1 340.1 336.0 331.8 327.2 322.1 316.4 309.5 300.6 286.9 260.0
∂( − rA ) −E A1E1 1 exp 1 C αAO (1 − X A )α1 CαAO2 = 2 ∂ T RT RT XA × (θ B + υ B X A )
α2
−
A2E2 −E exp 2 2 RT RT
1 × CβAO (θ R + υ R X A ) 1 CβAO2 (θS + υSX A )
β
β2
=0
(6-181)
Non-Isothermal Reactors
539
Figure 6-33. Fractional conversion XA versus Topt for reaction type A + B ↔ R.
At T = Topt and rearranging Equation 6-181, the optimum temperature progression Topt is E 2 − E1
Topt =
A E Cβ1 + β 2 − (α1 + α 2 ) 2 2 AO
R ln
(θ R + υ R X A )β1 (θS + υSX A )β 2 α α A1E1 (1 − X A ) 1 (θ B + υ BX A ) 2
(6-182)
k1
Consider the reaction A + B k[ R + S, which has a first order 2 kinetics with respect to each participating species, that is, α1 = α2 = β1 = β2 = 1. Also, from the stoichiometry, –υB = υR = υS = 1 and the feed conditions are such that θR = θS = 0, θB = 1. Equation 6-182 becomes Topt =
E 2 − E1
A E X 2 2 2 A R ln 2 A1E1 (1 − X A )
(6-183)
540
Modeling of Chemical Kinetics and Reactor Design
Using the kinetic parameters in Type 1 reaction with XA = 0.5, Topt is Topt =
(29, 600
− 11, 600)
(e 24.7 )(29, 600)(0.52 ) 1.987 ln 2 (11, 600)(0.5 )
= 353.36 K
The Microsoft Excel Spreadsheet (OPTIMUM63.xls) was used to evaluate Topt for varying values of XA. Table 6-12 gives the results of the spreadsheet calculation, and Figure 6-34 illustrates the profile of Topt against XA, showing that the optimum temperature progression decreases as the fractional conversion increases. Type 4 Reaction: aA
k1
[ k
rR + sS
2
The net rate of disappearance of A is
(− rA ) = k1CαA1 − k 2CβR1 CβS2
(6-159)
with CA = CAO(1 – XA)
(5-28)
CR = CAO(θR + υRXA)
(6-131)
CS = CAO(θS + υSXA)
(6-149)
Substituting Equations 5-28, 6-131 and 6-149 into Equation 6-159 gives
(− rA ) = k1CαAO1 (1 − X A )α1 1 − k 2 CβAO (θ R + υ R X A ) 1 CβAO2 (θS + υSX A )
β
At [∂(–rA)/∂T]XA = 0, then
β2
(6-184)
Non-Isothermal Reactors
541
Table 6-12 Optimum temperature progression for reaction type A + B ↔ R + S Kinetic parameters E1 E2 R A1 A2 CAO
11,600 29,600 1.987 17.2 41.9 1
Conv. XA
Temp (K)
0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.485 0.5 0.55 0.6 0.65 0.7 0.75 0.8 0.85 0.9 0.95 0.99
426.5 408.7 396.2 386.5 378.4 371.3 364.9 359.0 355.0 353.4 347.9 342.5 337.1 331.4 325.5 318.9 311.2 301.6 287.3 260.1
−E A1E1 1 exp 1 C αAO (1 − X A )α1 RT RT 2 −
−E A2E2 β β 1 2 θ R + υ R X A ) 1 CβAO θS + υS X A ) 2 = 0 (6-185) exp 2 CβAO ( ( 2 RT RT
Rearranging Equation 6-185 yields
542
Modeling of Chemical Kinetics and Reactor Design
Figure 6-34. Fractional conversion XA versus Topt for reaction type A + B ↔ R + S.
−E A1E1 1 exp 1 C αAO (1 − X A )α1 2 RT RT =
−E A2E2 1 +β2 exp 2 CβAO (θ R + υ R X A )β1 (θS + υSX A )β 2 RT RT 2
or 1 2 (θ R + υ R X A ) (θ S + υ S X A ) E − E1 A 2 E 2 C AO exp 2 = RT 1 A1E1C αAO (1 − X A )α1
β1
β +β
β2
(6-186)
The optimum temperature progression at T = Topt from Equation 6-186 is
Topt =
R ln
E 2 − E1
(θ R + υ R X A )β1 (θS + υSX A )β 2 α A1E1 (1 − X A ) 1
A E Cβ1 + β 2 − α1 2 2 AO
(6-187)
Non-Isothermal Reactors
543
If υR = υS = 1, θR = θS = 0, and α1 = β1 = β2 = 1, then Equation 6-187 becomes Topt =
E 2 − E1
(6-188)
A E C X2 R ln 2 2 AO A A1E1 (1 − X A )
Using the kinetic parameters in Type 1 reaction with XA = 0.5, Topt is Topt =
(29, 600 − 11, 600) (e 24.7 )(29, 600)(1.0)(0.52 ) 1.987 ln (11, 600)(0.5)
= 363.17 K
The Microsoft Excel Spreadsheet (OPTIMUM64.xls) was used to calculate Topt for values of XA (0.1 < XA < 0.99). Table 6-13 gives the results of the spreadsheet calculation, and Figure 6-35 shows the profile of the Topt versus XA. Adesina [14] considered the four main types of reactions for variable density conditions. It was shown that if the sums of the orders of the reactants and products are the same, then the OTP path is independent of the density parameter, implying that the ideal reactor size would be the same as no change in density. The optimal rate behavior with respect to T and the optimal temperature progression (T opt) have important roles in the design and operation of reactors performing reversible, exothermic reactions. Examples include the oxidation of SO2 to SO3 and the synthesis of NH3 and methanol CH3OH.
MINIMUM REACTOR VOLUME AT THE OTP OF A SINGLE CFSTR WITH A REVERSIBLE EXOTHERMIC REACTION k1
Consider the reversible first order reaction A k[2 R. It is possible to determine the minimum reactor volume at the optimum temperature Topt that is required to obtain a fractional conversion XA, if the feed is pure A with a volumetric flowrate of u. A material balance for a CFSTR is
544
Modeling of Chemical Kinetics and Reactor Design
Table 6-13 Optimum temperature progression for reaction type A ↔ R + S Kinetic parameters E1 E2 R A1 A2 CAO
11,600 29,600 1.987 17.2 41.9 1
Conv. XA
Temp (K)
0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.485 0.5 0.55 0.6 0.65 0.7 0.75 0.8 0.85 0.9 0.95 0.99
428.6 411.7 400.1 391.3 384.1 378.0 372.6 367.7 364.5 363.2 358.9 354.8 350.8 346.7 342.5 338.0 332.9 326.7 317.5 299.7
uC AO = uC A + ( − rA )VR + VR
dC A dt
(5-335)
Assuming there is no accumulation, then
VR
dC A =0 dt
uCAO = uCA + (–rA)VR
(5-158)
The rate expression for the first order reversible reaction is
Non-Isothermal Reactors
545
Figure 6-35. Fractional conversion XA versus Topt for reaction type A ↔ R + S.
(–rA) = k1CA – k2CR
(6-189)
where k1 = A1e–E1/RT and k2 = A2e–E2/RT. From stoichiometry, CAO – CA = CR and CA = CAO(1 – XA), CAO – CA = CAOXA. The volume VR of the reactor is VR =
u(C AO − C A ) (− rA )
or VR =
uC AO X A (− rA )
(5-160)
Substituting the constants k1 and k2 into the Equation 6-189 gives (–rA) = A1e–E1/RTCA – A2e–E2/RTCR or (–rA) = A1e–E1/RTCAO(1 – XA) – A2e–E2/RTCAOXA
(6-190)
546
Modeling of Chemical Kinetics and Reactor Design
At the optimum temperature T = Topt Topt =
E 2 − E1
A2E2XA R ln A1E1 (1 − X A )
(6-174)
and (–rA)opt = A1e–E1/RTopt CAO(1 – XA) – A2e–E2/RTopt CAOXA
(6-191)
The minimum volume VR min is
VR min =
uC AO X A (− rA )opt
(6-192)
The minimum residence time t min is t min =
VR min
(6-193)
u
For the minimum volume in a CFSTR under adiabatic condition, Equation 6-192 requires only that the operating temperature within the reactor be Topt. In this case, there is nothing about the mode of operation, such as the feed temperature TO or heat transfer, either within the reactor or upstream of it. However, if the CFSTR is operated adiabatically for specified conversion (XA) and molar flowrate (FAO = uCAO) without internal heat transfer, TO must be adjusted to a value obtained from the energy balance as determined by − ∆H R uρC P Topt − TO = (uC AO )(X A ) a
(6-194)
− ∆H R or GC P Topt − TO = (F )(X A ) a AO
(6-195)
(
)
(
)
OPTIMUM REACTOR SIZE The purpose of the reactor design is to acquire the optimum reactor size. However, the ideal optimum reactor size (V/FAO)opt, is obtained by integrating the optimum temperature profile. That is,
Non-Isothermal Reactors
547
XA
f dX A V = ∫ FAO = uC AO opt X ( − rA )opt
(6-196)
Ai
Equation 6-196 may be impossible to obtain because the expression for (–rA)opt is nonlinear in Topt. The numerical integration method is therefore employed. If Topt, corresponding to the inlet conversion, XA, is greater than the maximum allowable temperature Tmax at which the reactor can operate, the integration process must be adjusted so that the reactor operates isothermally at Tmax until the conversion falls on the optimum temperature progression profile. Then the integration is made to follow the OTP. The following algorithm is used for the modified integration [13]. Step 1: Using the inlet conversion, XAi, calculate Topt: (a) If T opt ≥ Tmax, use T max to calculate k1 and k 2, hence (–rA)opt. (b) If T opt < T max, use T opt to calculate k 1 and k 2 , hence (–rA)opt. Step 2: Increase XAi, from XAi to XAi + h, where h is the step size for XAi in the numerical integration process. Again, evaluate Topt. Step 3: Repeat the check in step 1 followed by step 2 until (1b) is satisfied. At this point, the OTP is now being followed. Step 4: Increase X Ai to X Ai + h; estimate Topt. Use this value to calculate k1 and k2, and hence (–rA)opt. Step 5: Repeat step 4 until XA = XAF. Step 6: Use any numerical method of integration to determine (V/FAO)opt in Equation 6-196. Example 6-14 k1
For an exothermic, liquid-phase, reversible reaction A k[ R occurring 2 in a CFSTR, with a feedrate of 600 mol/min–1, a feed concentration (CAO) of 6 mol/L–1 (CRO = 0) and a fractional conversion (XA) of 0.65, calculate 1. The optimal temperature (T/K) in the reactor for minimum volume.
548
Modeling of Chemical Kinetics and Reactor Design
2. The minimum volume and residence time required for the reactor. 3. The feed temperature (TO) for the adiabatic operation at the optimal temperature Topt. Additional data (rate constants taken from Levenspiel [11]): (–rA) = rR = k1CA – k2CR mol L–1 min–1 k1 = exp17.2 −
48, 900 , min −1 RT
k 2 = exp 41.9 −
123, 800 , min −1 RT
(–∆HR/a) = 70,000 Jmol–1; CP(stream) = 4.2 Jg–1K–1 ρ(stream) = 1,000 gL–1; R = 8.314 Jmol–1K–1 CP(stream) = 4.2 J/g • K Solution The optimum temperature Topt is determined by Equation 6-174: Topt =
E 2 − E1
A2E2XA R ln A1E1 (1 − X A )
E2 = 123,800 E1 = 48,900 A2 = exp(41.9) = 15.74 × 1017 A1 = exp(17.2) = 29.5 × 106 R = 8.314 J/mol • K (1) The optimum temperature Topt is:
(6-174)
Non-Isothermal Reactors
Topt =
549
(123, 800 − 48, 900) 15.74 × 1017 × 123, 800 × 0.65 8.314 ln 6 29.5 × 10 × 48, 900 × 0.35
Topt = 343.2 K (70.1°C) The minimum volume VR is determined by Equation 6-192 as
VR =
uC AO X A (− rA )opt
(6-192)
The rate expression at the optimum temperature T = Topt is
(− rA )opt = A1e − E1 RTopt C AO (1 − X A ) − A 2 e − E 2 RTopt C AO X A
−48, 900 (− rA )opt = 29.5 × 10 6 exp 8.314 × 343.2 (
× 6.0 × 0.35 )
−123, 800 − 15.74 × 1017 exp × 6.0 × 0.65 (8.314 × 343.2)
(–rA)opt = 1.353 mol L–1 min–1 FAO = uCAO Therefore, the volumetric flowrate u=
FAO 600 mol L L = • = 100 C AO 6 min mol min
(2) The minimum volume is determined by
VR min =
100 × 6.0 × 0.65 u C AO X A = 1.353 ( − rA )opt
L × mol × L • min L mol min
550
VR
Modeling of Chemical Kinetics and Reactor Design
min
= 288 l
The minimum residence time t min = VR / u = 288 /100 min
t min = 2.9 min (3) The feed temperature TO for the adiabatic operation at the optimal temperature Topt is determined from the heat balance, –G∆h + Q = 0, where G = ρu and ∆h = C p dT +
− ∆H R ∆m a a MA .
Therefore,
− ∆H R ∆m A +Q= 0 −ρu C p ∆T + a M A At adiabatic condition Q = 0
(
)
−ρuC p Topt − TO − u
− ∆H R (C A − C AO ) = 0 a
Rearranging the above equation gives
(
)
ρuC p TO − Topt = − u
(
)
− ∆H R (C AO − C A ) a
or ρuC p TO − Topt = −
TO = Topt −
− ∆H R (− rA )opt VR a
1 − ∆H R ( − rA )opt VR uρC p a
(70, 000)(1.353)(288) TO = 343.2 − (100)(1, 000)(4.2)
J mol mol • L • min • L g L J • • L min g • K
Non-Isothermal Reactors
551
TO = 343.2 – 64.94 TO = 278.3 K (5.1°C). An Excel spreadsheet program (Example6-14.xls) was developed for this example.
REFERENCES 1. Dodge, B. F., Chemical Engineering Thermodynamics, McGrawHill, New York, 1944. 2. Wilson, K. B., Trans. Inst. Chem. Engrs, 24, 77, 1946. 3. Ergun, S., “Fluid flow through packed columns,” Chem. Eng. Prog. 48, No. 2, 89, 1952. 4. Handley, D. and Heggs, P. J., Trans. Instn. Chem. Engrs., 46-T251, 1968. 5. McDonald, I. F., El-Sayed, M. S., Mow, K., and Dullien, F. A. L., Ind. Eng. Chem. Fund., 18, 199, 1979. 6. Hicks, R. E., Ind. Eng. Chem. Fund., 9, 500, 1970. 7. Wentz, G. A. and Thodos, G., AIChEJ, 9, 81, 1963. 8. Tallmadge, J. A., AIChEJ, 16, 1092, 1970. 9. Perry, R. and Green, D., Perry’s Chemical Engineer’s Handbook, 6th ed., pp. 5–54, McGraw-Hill International edition, 1984. 10. Smith, J. M., Chemical Engineering Kinetics, 3rd ed., McGrawHill Book Co., 1981. 11. Levenspiel, O., Chemical Reaction Engineering, 3rd ed., John Wiley, 1999. 12. Levenspiel, O., Chemical Reactor Omnibook, Oregon State University Press, 1979. 13. Omoleye, J. A., Adesina, A. A., and Udegbunam, E. O., “Optimal design of nonisothermal reactors: Derivation of equations for the rate-temperature conversion profile and the optimum temperature progression for a general class of reversible reactions,” Chem. Eng. Comm., Vol. 79, pp. 95–107, 1989. 14. Adesina, A. A., “Non-isothermal reactor design for variable density systems,” The Chemical Eng. J, 47, pp. 17–24, 1991. 15. Levenspiel, O., private communication. 16. Smith, E. L., private communication. 17. Adesina, A. A., private communication.
552
Modeling of Chemical Kinetics and Reactor Design
CHAPTER SEVEN
Fluid Mixing in Reactors INTRODUCTION The various types of reactors employed in the processing of fluids in the chemical process industries (CPI) were reviewed in Chapter 4. Design equations were also derived (Chapters 5 and 6) for ideal reactors, namely the continuous flow stirred tank reactor (CFSTR), batch, and plug flow under isothermal and non-isothermal conditions, which established equilibrium conversions for reversible reactions and optimum temperature progressions of industrial reactions. Various types of reactors are increasingly employed in the mixing of reactants to achieve the required yield at a given rate. For an example, in the development of reactor design equations for a CFSTR, an assumption was made that all the molecules move freely in the fluid with no interference from surrounding molecules. The fluid mixing, in this case, was assumed to be instantaneous. Molecules added to the reactors were indistinguishable from those already present. For real fluids, the time required to attain uniform concentration in a CFSTR depends on the intensity of turbulence, which may not be instantaneous. Molecular diffusion allows the movement of different molecules across the boundaries of the liquid elements, thereby reducing the difference between elements. Molecular diffusion is essential to achieve mixing between two liquids and complete the mixing process. If the fluids being mixed are gases, the rate of molecular diffusion is very high so the time required is extremely small. In the case of liquids where the rate of molecular diffusion is slow, knowledge is required of the turbulence so that an estimate of the size of the smallest eddy and time for molecular diffusion can be established. Danckwerts [1] gave a set of criteria to provide a measure of the level of mixing. The scale of segregation measures the size of the 552
Fluid Mixing in Reactors
553
unmixed clumps of pure components; the intensity of segregation describes the effect of molecular diffusion on the mixing process. It is defined as the difference in concentration between the neighboring clumps of fluid. Levenspiel [2] considered when two fluids are mixed together, the molecular behavior of the dispersed fluid falls between two extremes. If molecules are completely free to move about, the dispersed fluid behaves as a microfluid and exhibits no fluid segregation. At the opposite extreme, the dispersed fluid remains as clumps containing a large number of molecules and is termed a macrofluid. Furthermore, as the macrofluid is transformed to a microfluid by physical mixing processes (e.g., turbulence or molecular diffusion), the degree and scale of segregation (i.e., the average of the segregated clumps) decrease. An important mixing operation involves bringing different molecular species together to obtain a chemical reaction. The components may be miscible liquids, immiscible liquids, solid particles and a liquid, a gas and a liquid, a gas and solid particles, or two gases. In some cases, temperature differences exist between an equipment surface and the bulk fluid, or between the suspended particles and the continuous phase fluid. The same mechanisms that enhance mass transfer by reducing the film thickness are used to promote heat transfer by increasing the temperature gradient in the film. These mechanisms are bulk flow, eddy diffusion, and molecular diffusion. The performance of equipment in which heat transfer occurs is expressed in terms of forced convective heat transfer coefficients. This chapter reviews the various types of impellers, the flow patterns generated by these agitators, correlation of the dimensionless parameters (i.e., Reynolds number, Froude number, and Power number), scale-up of mixers, heat transfer coefficients of jacketed agitated vessels, and the time required for heating or cooling these vessels.
MIXING AND AGITATION OF FLUIDS Many operations depend to a great extent on effective mixing of fluids. Mixing refers to any operation used to change a non-uniform system into a uniform one (i.e., the random distribution of two or more initially separated phases); agitation implies forcing a fluid by mechanical means to flow in a circulatory or other pattern inside a vessel. Mixing is an integral part of chemical or physical processes
554
Modeling of Chemical Kinetics and Reactor Design
such as blending, dissolving, dispersion, suspension, emulsification, heat transfer, and chemical reactions. Dispersion characteristics can be considered as the mixing of two or more immiscible liquids, solids and liquids, or liquids and gases, into a pseudo-homogeneous mass. Small drops are created to provide contact between immiscible liquids. These liquids are mixed for specific purposes, namely solvent extraction, removal or addition of heat, and to affect mass transfer rates in reactors. The terms dispersion and emulsion are often used interchangeably. Dispersion is a general term that implies distribution, whereas emulsion is a special case of dispersion. Dispersion is a two-phase mixture in which drops may coalesce. The material present in a larger quantity is referred to as the continuous phase and the material present in a smaller quantity is called the dispersed phase. An emulsion is a two-phase mixture of very fine drops in which little or no coalescence occurs. The stability of an emulsion depends on surface ion activity, which is a function of particle size. Common dispersions are water and hydrocarbons, and acidic or alkaline solutions combined with organic liquids. Table 7-1 summarizes the principal purposes for agitating fluids. AGITATION EQUIPMENT Various types of vessels and tanks of differing geometrical shapes and sizes are used for mixing fluids. The top of the vessel may be open or sealed. A typical batch reactor, as discussed in Chapter 4, is applicable in many operations. The vessel bottom is normally not flat,
Table 7-1 Characteristics for agitating fluids 1. Blending of two miscible or immiscible liquids. 2. Dissolving solids in liquids. 3. Dispersing a gas in a liquid as fine bubbles (e.g., oxygen from air in a suspension of microorganism for fermentation or for activated sludge treatment). 4. Agitation of the fluid to increase heat transfer between the fluid and a coil or jacket. 5. Suspension of fine solid particles in a liquid, such as in the catalytic hydrogenation of a liquid where solid catalyst and hydrogen bubbles are dispersed in the liquid. 6. Dispersion of droplets of one immiscible liquid in another (e.g., in some heterogeneous reaction process or liquid-liquid extraction).
Fluid Mixing in Reactors
555
but rounded to eliminate sharp corners or regions into which the fluid currents would not penetrate; dished ends are most common. The liquid depth is approximately equal to the diameter of the tank. An impeller is mounted on an overhung shaft, (i.e., a shaft supported from above). The shaft is motor driven; this is sometimes directly connected to the shaft, but is more often connected through a speed-reducing gearbox. Other attachments include inlet and outlet lines, coils, jackets, and wells for thermometers. Figure 7-1 shows a typical standard tank
Figure 7-1. Standard tank configuration.
556
Modeling of Chemical Kinetics and Reactor Design
configuration. The geometric proportions of the agitation system, which are considered a typical standard design are given in Table 7-2. These relative proportions form the basis of the major correlations of agitation performance from various studies. There are cases where W/D A = 1/8 and J/D T = 1/10 for some agitator correlations. Usually, 4 baffles are used and the clearance between the baffles and the wall is about 0.1–0.15 J. This ensures that the liquid does not form stagnant pockets between the baffle and the wall. The number of impeller blades varies from 4 to 16, but is generally between 6 and 8. Mixing by agitation of liquids normally involves the transfer of momentum from an impeller to the liquid. In some cases, mixing is achieved by gas injection or circulation via a pump loop. An impeller, which is mounted on a shaft driven by an electric motor, is divided into two operation categories: • Where momentum is transferred by shearing stresses, in which the transfer is perpendicular to the direction of flow. This category includes the rotating disc and cone agitators. • The momentum is transferred by normal stresses, in which the transfer is parallel to the direction of flow. This category includes the paddle, propeller, and turbo mixer agitators.
Table 7-2 Geometric proportions for a standard agitation system DA 1 = DT 3
H =1 DT
J 1 = D T 12
E =1 DA
W 1 = DA 5
L 1 = DA 4
B R DA H DT E J L W
= = = = = = = = =
number of blades on impeller number of baffles agitator diameter liquid height tank diameter height of the agitator from the bottom of the tank baffle width agitator blade length agitator blade width
Fluid Mixing in Reactors
557
Agitation plays an essential role in the success of many chemical processes, and there is a wide range of commercially available impellers that can provide the optimum degree of agitation for any process. The problem arises in selecting the best impeller for the required process. Equipment manufacturers often provide expert guidance, but it is beneficial for designers and engineers to acquire fundamental knowledge of various types of impellers. The process objective of an impeller is the primary factor that determines its selection. These objectives, summarized in Table 7-1, together with physical properties such as viscosity play an important role in the selection of impellers in laminar, transitional, and turbulent operations. In general, impellers can be classified into two main groups. • Impellers with a small blade area, which rotate at high speeds. These include turbines and marine propellers. • Impellers with a large blade area, which rotate at low speeds. These include anchors, paddles, and helical screws. The latter impellers are very effective for high-viscosity liquids and depend on a large blade area to produce liquid movement throughout the vessel. Since they are low-shear impellers, they are useful for mixing shear-thickening liquids. Figure 7-2 shows a typical gate anchor agitator. Anchor agitators operate very close to the vessel wall with a radial clearance equal to 0.0275 DA. The shearing action of the anchor blades past the vessel wall produces a continual interchange of liquid between the bulk liquid and the liquid film between the blades and the wall. For heat transfer applications, anchors are fitted with wall scrapers to prevent the buildup of a stagnant film between the anchor and the vessel wall. The anchor impeller is a good blending and heat transfer device when the fluid viscosity is between 5,000 and 50,000 cP (5 and 50 Pas). Below 5,000 cP, there is not enough viscous drag at the tank wall to promote pumping, resulting in a swirling condition. At viscosities greater than 50,000 cP (50 Pas), blending and heat transfer capabilities decrease as pumping capacity declines and the impeller “slips” in the fluid. Helical screws operate in the laminar range at normally high impeller to vessel diameter ratio (D A/D T) with a radial clearance equal to 0.0375 DA. The impeller usually occupies one-third to one-half of the vessel diameter. They function by pumping liquid from the bottom of a tank to the liquid surface. The liquid returns to the bottom of the
558
Modeling of Chemical Kinetics and Reactor Design
Figure 7-2. Gate anchor agitator. (Source: Holland, F. A. and Bragg, R. Fluid Flow for Chemical Engineers, 2nd ed., Edward Arnold, 1995.)
tank to fill the space created when fresh liquid is pumped to the surface. Figure 7-3 shows the flow pattern in a baffled helical screw tank. Baffles set away from the tank wall create turbulence and, thus, enhance the entrainment of liquid in contact with the tank wall. These are not required if the helical screw is placed in an off-centered position because the system becomes self-baffling. These impellers are useful in heat transfer application when it is essential that the fluid closest to the wall moves at high velocities. Turbulent impellers are classified as axial or radial flow impellers. Axial flow impellers cause the tank fluid to flow parallel to the impeller’s rotation axis. Radial flow impellers cause the tank fluid to
Fluid Mixing in Reactors
559
Figure 7-3. Flow pattern in a baffled helical screw system. (Source: Holland, F. A. and Bragg, R. Fluid Flow for Chemical Engineers, 2nd ed., Edward Arnold, 1995.)
flow perpendicular to the impeller’s rotation axis. Small blade, highspeed impellers are used to mix low to medium viscosity liquids. Figures 7-4 and 7-5, respectively, show the six-flat blade turbine and marine propeller-type agitators. Figure 7-6 shows flat blade turbines used to produce radial flow patterns perpendicular to the vessel wall. In contrast, Figure 7-7 depicts marine-type propellers with axial flow (text continued on page 562)
560
Modeling of Chemical Kinetics and Reactor Design
Figure 7-4. Six flat blade turbine. (Source: Holland, F. A. and Bragg, R. Fluid Flow for Chemical Engineers, 2nd ed., Edward Arnold, 1995.)
Figure 7-5. Marine propeller. (Source: Holland, F. A. and Bragg, R. Fluid Flow for Chemical Engineers, 2nd ed., Edward Arnold, 1995.)
Fluid Mixing in Reactors
561
Figure 7-6. Radial flow pattern produced by a flat blade turbine. (Source: Holland, F. A. and Bragg, R. Fluid Flow for Chemical Engineers, 2nd ed., Edward Arnold, 1995.)
Figure 7-7. Axial flow pattern produced by a marine propeller. (Source: Holland, F. A. and Bragg, R. Fluid Flow for Chemical Engineers, 2nd ed., Edward Arnold, 1995.)
562
Modeling of Chemical Kinetics and Reactor Design
(text continued from page 559)
patterns. Both of these types of impellers are suitable to mix liquids with dynamic viscosities between 10 and 50 Pas. Several methods of selecting an impeller are available [3,4]. Figure 7-8 shows one method based on liquid viscosity and tank volume, and Table 7-3 illustrates another based on liquid viscosity alone. Axial flow devices such as high-efficiency (HE) impellers and pitched blade turbines give better performance than conventional pitched blade turbines. They are best suited to provide the essential flow patterns in a tank that keep the solids suspended. High-efficiency impellers effectively convert mechanical energy to vertical flow
Figure 7-8. Impeller selection. (Source: Penny, W. R. “Guide to trouble free mixers,” Chem. Eng., 77(12), 171, 1970.)
Fluid Mixing in Reactors
563
Table 7-3 Impeller selection guide Type of impeller Anchor Propeller Flat-blade turbine Paddle Gate Helical screw Helical ribbon Extruders
Range of liquid, cP 102 – 2 × 100 – 104 100 – 3 × 102 – 3 × 103 – 105 3 × 103 – 104 – 2 × >106
103 104 101 3 × 105 106
Viscosity, kg/m – sec 10–1 – 2 10–3 – 101 10–3 – 3 × 101 10–1 – 3 × 101 100 – 102 3 – 3 × 102 101 – 2 × 103 >103
Source: Holland, F. A., and Chapman, F. S. Liquid Mixing and Processing in Stirred Tanks, Reinhold, New York, 1966.
required to overcome the effects of gravity on solids in suspension. They also provide the same levels of solids suspension at reduced capital and operating costs. FLOW PATTERN In fluid agitation, the direction as well as the magnitude of the velocity is critical. The directions of the velocity vectors throughout an agitated vessel are referred to as the flow pattern. Since the velocity distribution is constant in the viscous and turbulent ranges, the flow pattern in an agitated vessel is fixed. During the mixing of fluids, it is essential to avoid solid body rotation and a large central surface vortex. When solid body rotation occurs, adequate mixing is not achieved because the fluid rotates as if it were a single mass as shown in Figure 7-9a. Centrifugal force of the fluid causes a central surface vortex to be thrown outward by the impeller. Entrainment of air results if the vortex reaches an impeller, resulting in reduced mixing of the fluids. This situation can be averted by installing baffles on the vessel walls, which impede rotational flow without interfering with radial or longitudinal flow. Effective baffling is attained by installing vertical strips perpendicular to the wall of the tank. With the exception of large tanks, four baffles are adequate to prevent swirling and vortex formation. For propellers, the width of the baffle should be less one-eighteenth the diameter of the tank; for
564
Modeling of Chemical Kinetics and Reactor Design
Figure 7-9. Agitator flow patterns. (a) Axial or radial impellers without baffles produce vortex. (b) Off-center location reduces the vortex. (c) Axial impeller with baffles. (d) Radial impeller with baffles. (Source: Walas, S. M., Chemical Process Equipment—Selection and Design, Butterworths Series in Chemical Engineering, 1988.)
turbines, less one-twelfth the tank diameter. Figure 7-9 shows the various flow patterns of radial and axial impellers. Reducing vortex formation may also be achieved by placing an impeller in an off-center position. This creates an unbalanced flow pattern, reducing or eliminating the swirl and thereby increasing or maximizing the power consumption. The exact position is critical, since too far or too little off-center in one direction or the other will cause greater swirling, erratic vortexing, and dangerously high shaft stresses. Changes in viscosity and tank size also affect the flow pattern in such vessels. Off-center mounting of radial or axial flow impellers is readily employed as a substitute for baffled tank installations. It is common practice with propellers, but less with turbine agitators. Offcenter mounting can also be useful for a turbine operated in the medium viscosity range and with non-Newtonian fluids where baffles cause stagnation with little swirl of the fluid. Off-center mountings have been quite effective in the suspension of paper pulp. Figure 7-10 illustrates an angular off-center position for propellers, which is effective without using baffles.
Fluid Mixing in Reactors
565
Figure 7-10. Flow pattern of propellers in an eccentric angle and off-centered position.
566
Modeling of Chemical Kinetics and Reactor Design
Once swirling stops, the specific flow pattern in the tank depends on the type of impeller. Paddle agitators and flat-blade turbines promote good radial flow in the plane of the impeller with the flow dividing the wall to form two separate circulation patterns (Figure 7-6). One portion flows down along the wall and back to the center of the impeller from below, and the other flows up toward the surface and back to the impeller from above. Propeller agitators drive the liquid down to the bottom of the tank, where the stream spreads radially in all directions toward the wall, flows upward along the wall, and returns to the suction of the propeller from the top. The earlier Figure 7-7 shows the flow pattern of a propeller agitator. Propellers are employed when heavy solid particles are suspended. Table 7-4 shows flow patterns and applications of some commercially available impellers. Generally, the axial flow pattern is most suitable for flow sensitive operation such as blending, heat transfer, and solids suspension, while the radial flow pattern is ideal for dispersion operations that require higher shear levels than are provided by axial flow impellers. Myers et al. [5] have described a selection of impellers with applications. Further details on selection are provided by Uhl and Gray [6], Gates et al. [7], Hicks et al. [8] and Dickey [9]. POWER REQUIREMENT FOR AGITATION The flow mechanism in a mixing tank is very complex. Various techniques, including computational fluid dynamics (CFD) and computational fluid mixing (CFM) tools, are employed together with experimental data to establish improvements in mixing with increased yield. Estimating the power consumption for any agitator is essential for design. Generally, the desired requirements for the system to be mixed will categorize the type of impeller to be used. Laboratory tests on the system can establish the appropriate speed for the maintenance of isotropic turbulence in the mixing vessel. Therefore, estimating the power consumption for a large-scale mixing operation must include scale-up considerations. These requirements may be determined from the Navier-Stokes equation or analyzed by a dimensional analysis of the mixing operation. The power consumed by an agitator depends on its dimensions and the physical properties of the fluids being mixed (i.e., density and viscosity). Since there is a possibility of a gas-liquid surface being
Fluid Mixing in Reactors
Table 7-4 Impellers and flow patterns
Source: Myers, K., et al., Agitation for Success, The Chemical Engineer, Oct. 10, 1996. Reproduced with permission of IChemE.
567
568
Modeling of Chemical Kinetics and Reactor Design
distorted, as in the formation of a vortex, gravity forces must also be considered. Consider a stirred tank vessel having a Newtonian liquid of density ρ and viscosity µ is agitated by an impeller of diameter DA, rotating at a rotational speed N. Let the tank diameter be DT, the impeller width W, and the liquid depth H. The power P required for agitation of a single-phase liquid can be expressed as: P = f(ρa, µb, Nc, gd, DAe , DTf , Wg, Hh)
(7-1)
There are nine variables and three primary dimensions, and therefore by Buckingham’s theorem, Equation 7-1 can be expressed by (9-3) dimensionless groups. Employing dimensional analysis, Equation 7-1 in terms of the three basic dimensions (mass M, length L, and time T) yields: Power = ML2T–3. Substitution of the dimensions into Equation 7-1 gives, ML2T–3 = f{(ML–3)a, (ML–1T–1)b, T–c, (LT–2)d, Le, Lf, Lg, Lh} (7-2) Equating the exponents of M, L, and T on both sides of Equation 7-2 gives M: 1 = a + b
(7-3)
L:
2 = –3a – b + d + e + f + g + h
(7-4)
T:
–3 = –b – c – 2d
(7-5)
From Equation 7-3 a = 1 – b
(7-6)
Substituting Equation 7-6 into Equation 7-4 gives 2 = –3(1 – b) – b + d + e + f + g + h 5 = 2b + d + e + f + g + h From Equation 7-5 –3 = –b – c – 2d b = 3 – c – 2d, or
(7-7)
Fluid Mixing in Reactors
c = 3 – b – 2d
569
(7-8)
From Equation 7-7 e = 5 – 2b – d – f – g – h
(7-9)
Substituting a, c, and e on the right side of Equation 7-1 yields
(
)
P = K ρ1− b , µ b , N 3 − b − 2 d , g d , D 5A− 2 b − d − f − g − h , D fT , W g , H h (7-10) Rearranging and grouping the exponents yields, f g h b d µ g D T W H 3 5 P = K ρN D A (7-11) ρND 2A N 2 D A D A D A D A
or µ b g d D f W g H h P T = K 2 2 ρN 3D 5A ρ ND N D D A A A DA DA
(7-12)
The dimensionless parameters are: The Power number, N p =
Pg C ρN 3D 5A
gC = dimensional gravitational constant
32.174
lbm ft • lbf sec 2
1 kg • m/N • sec2 The Reynolds number, N Re =
The Froude number, N Fr =
ρND 2A µ
N2DA g
570
Modeling of Chemical Kinetics and Reactor Design
Substituting these dimensionless numbers into Equation 7-12 yields, f g h −d DT W H N p = K N −Reb N Fr DA DA DA
(7-13)
SIMILARITY Equality of all groups in Equation 7-13 assures similarity between systems of different sizes. The types of similarity are geometric, kinematic, and dynamic. The last three terms of Equation 7-13 represent the conditions for geometric similarity, which require that all corresponding dimensions in systems of different sizes have the same ratio to each other. For geometric similarity, Equation 7-13 becomes N P = K N −Reb N −Frd
(7-14)
The constant K and the exponents b and d must be determined for the particular type of agitator, its size and location in the tank, the dimensions of the tank, and the depth of the liquid. Kinematic similarity exists between two systems of different sizes when they are geometrically similar and when the ratios of velocities between corresponding points in one system are equal to those in the other. Dynamic similarity exists between two systems when, in addition to being geometrically and kinematically similar, the ratios of forces between corresponding points in one system are equal to those in the other. The value of NRe determines whether the flow is laminar or turbulent and is a significant group affecting the power consumption. The Froude number NFr, representing the ratio of inertial to gravitational forces, is only significant when the liquid in the tank swirls to such an extent that a deep vortex is formed and the wave or surface effects become important. In an unbaffled vessel, a balance between the inertial and gravitational forces determines the shape of any vortex. The Power number NP may be considered as a drag coefficient or friction factor. Experimental data on power consumption are generally plotted as a function of the Power number NP versus Reynolds number NRe, that is by rearranging Equation 7-14.
Fluid Mixing in Reactors
Φ=
NP = K N −Reb −d N Fr
571
(7-15)
For a fully baffled tank, b = 0 and Φ = NP. A generalized plot of Equation 7-15 is shown in Figure 7-11. The power correlation indicates three ranges of liquid motion: laminar (viscous), transition, and turbulent. The laminar or viscous range occurs below a Reynolds number of 10. The expected result of the Power number being inversely proportional to the Reynolds number is also confirmed by experimental data. The Froude effects are unimportant and a logarithmic plot of the relation between Power number and Reynolds number gives a slope of –1 in this range. Fully turbulent agitation occurs above a Reynolds number of 10,000. The range between these limits can be described as the transition flow because flow patterns change depending on the Reynolds number. Figure 7-12 shows the Power number versus Reynolds number plot for the unbaffled system. Both Figures 7-11 and 7-12 are identical to point C where NRe ≅ 300. As the Reynolds
Figure 7-11. Power curve for the standard tank configuration. (Source: Holland, F. A. and Bragg, R. Fluid Flow for Chemical Engineers, 2nd ed., Edward Arnold, 1995.)
572
Modeling of Chemical Kinetics and Reactor Design
Figure 7-12. Power curve for the standard tank configuration without baffles. (Source: Holland, F. A. and Bragg, R. Fluid Flow for Chemical Engineers, 2nd ed., Edward Arnold, 1995.)
number for mixing increases beyond point C in the unbaffled system, vortexing increases and the Power number falls sharply. Figure 7-13 shows the Power number as a function of the Reynolds number for shear thinning fluids. The full line gives the Newtonian Power number obtained by Rushton et al. [10] for a flat-blade turbine system, while the dashed line shows Metzner and Otto’s [11] plot for shear thinning liquids. Figure 7-13 illustrates that at no point is the shear thinning power curve higher than the Newtonian power curve. Therefore, the use of the Newtonian power curve to determine the power will give a conservative value when used for shear thinning liquids. Figure 7-14 shows Power number correlations for various types of agitators. In the fully turbulent flow, the curve becomes horizontal and the Power number NP is independent of the Reynolds number. Rushton et al. [10] performed extensive measurements of the power requirements for geometrically similar systems and found that for baffled tanks, the Froude number plays no part in determining the power requirements, as vortices do not form in such systems. For unbaffled systems, the Froude number plays a part above NRe of about
Fluid Mixing in Reactors
573
Figure 7-13. Deviation from Newtonian power curve for shear thinning liquids. (Source: Holland, F. A. and Bragg, R. Fluid Flow for Chemical Engineers, 2nd ed., Edward Arnold, 1995.)
300. They reported NP = 6.3 in the turbulent range of 10,000. After extensive curve fitting of their experimental data, a single curve was obtained for any particular unbaffled configuration. If Φ is plotted as a function of NRe where Φ is defined as Φ = NP Φ=
(a − N[ Fr
for NRe < 300 NP
log N Re ) b
]
for NRe > 300
(7-16)
where a and b are constants for any configuration (Figure 7-14). Dickey and Fenic [12] observed that the impeller characteristics have significant influence on the Power number correlation.
574
Modeling of Chemical Kinetics and Reactor Design
Figure 7-14. Power number versus Reynolds number correlation for common impellers. (Source: Ruchton et al., Chem. Eng. Prog., 46, No. 8, 495, 1950. Reprinted with permission of AIChE. Copyright © 1950. All rights reserved.)
Two characteristics of Figure 7-14 are: 1. At low NRe < 1.0, N P ∝ 1/N Re, independent of the presence of baffles. 2. At high Reynolds, at which most mixing operations are performed, the Power number is constant, that is, NP ∝ P/ρN3D A5 = constant. Rushton et al. [10] investigated the effect of varying the tank geometrical ratios and the correlation of the Power number with Reynolds number. At high Reynolds number, it was inferred that,
Fluid Mixing in Reactors
575
• Φ is relatively unchanged when DT/DA is varied from 2 to 7 for turbine- and propeller-agitated baffled systems. • Φ is unchanged when H/DA is varied from 2 to 4. • Φ is unaltered when E/DA is changed from 0.7 to 1.6. • Φ changes to Φ ∝ (J/D A) 0.3 when J/D T is changed from 0.05 to 0.17. • Φ depends on the number of blades in the turbine impeller as: Φ ∝ (B/6)0.8 if B < 6 and Φ ∝ (B/6)0.7 if B > 6 (where B = number of impeller blades). • If off-centered and inclined propellers without baffles or sideentering propellers without baffles are used, no vortex forms and the Φ versus NRe curve for the corresponding baffled tank can be used to estimate the power requirements. These conclusions are speculative and experimental curves must be generated if more than one geometrical ratio differs from the standard value. The power consumed by an agitator at various rotational speeds and physical properties (e.g., viscosity and density) for a system’s geometry can be determined from the Power number correlation. The procedure involves: • Calculating the Reynolds number NRe for mixing. • Reading the Power number NP from the appropriate curve, and calculating the power P given by P = N P • ρN 3D 5A
(7-17)
[(a − log N Re ) b ] or P = ΦρN 3D 5A • N Fr
(7-18)
Equations 7-17 and 7-18 are the power consumed by the agitator. Additional power is required to overcome electrical and mechanical losses. A contingency of motor loading as a percentage (e.g., 85%) is added when selecting the motor. Equation 7-17 can also be rearranged to determine impeller diameter when it is desired to load an agitator impeller to a given power level. The torque delivered to the fluid by an impeller from its speed and power draw is determined by: τ=
N P ρN 2 D 5A P = N−m 2 πN 2π
(7-19)
576
Modeling of Chemical Kinetics and Reactor Design
The primary pumping capacity of an impeller is determined by the impeller diameter, the Pumping number, and the rotational speed. The Pumping number NQ is defined by [13]
NQ =
QP ND3A
(7-20)
The Pumping number is used to determine the pumping rate QP of an impeller, where QP = effective pumping capacity, m3/sec N = impeller rotational speed, sec–1 DA = impeller diameter, m Hicks et al. [8] developed a correlation involving the Pumping number and impeller Reynolds number for several ratios of impeller diameter to tank diameter (DA/DT) for pitched-blade turbines. From this correlation, QP can be determined, and thus the bulk fluid velocity from the cross-sectional area of the tank. The procedure for determining the parameters is iterative because the impeller diameter DA and rotational speed N appear in both dimensionless parameters (i.e., NRe and NQ). Figure 7-15 shows plots of Pumping number NQ and Power number NP as functions of Reynolds number NRe for a pitched-blade turbine and high-efficiency impeller. Hicks et al. [8] further introduced the scale of agitation, SA, as a measure for determining agitation intensity in pitched-blade impellers. The scale of agitation is based on a characteristic velocity, v, defined by
v=
QP AV
(7-21)
where v = characteristic velocity, m/sec AV = cross-sectional area of the tank, m2 The characteristic velocity can be expressed as: D2 v ∝ N Q N D A A2 DT
(7-22)
Fluid Mixing in Reactors
577
Figure 7-15. Power number and Pumping number as functions of Reynolds number for a pitched-blade turbine and high-efficiency impeller. (Source: Bakker, A., and Gates L. E., “Properly Choose Mechanical Agitators for Viscous Liquids,” Chem. Eng. Prog., pp. 25–34, 1995.)
In geometrically similar systems, the characteristic velocity becomes v ∝ NQNDA
(7-23)
Thus, during geometric scale-up, the characteristic velocity is held constant by holding N QNDA constant. QP is determined from the Pumping number and Figure 7-15. S A is a linear function of the characteristic velocity and is determined by SA = 32.8 v
(7-24)
Accordingly, a value of SA equal to 1 represents a low level and 10 shows a high level of agitation intensity. The 1–10 range of agitation intensity accounts for about 95% or more of all turbineagitation applications, enabling it to be suited for a wide range of process operations. Gates et al. [14] gave guidelines on how to relate SA to specific process applications.
578
Modeling of Chemical Kinetics and Reactor Design
MIXING TIME CORRELATION A distinction was made earlier between mixing and agitation. The third term in liquid mixing is blending. This refers to the intermingling of miscible fluids to produce some degree of uniformity. A criterion for good mixing may only be visual. For example, it could be a particular color from two different color liquids, or the color change of an acid-base indicator that determines the liquid blending times. Characterization of blending in agitated vessels is usually in terms of mixing time. This is the time required to achieve some specified degree of uniformity after introduction of a tracer. Table 7-5 gives various techniques for determining blending time. Each technique measures a different degree of uniformity, therefore, the time required for blending may differ from one method to the other. The correlation of blending time as derived from dimensional analysis is applicable to all techniques. Uhl and Gray [6] summarized many of the experiments and correlations on blending and mixing times. For a given tank and impeller or geometrically similar systems, the mixing time is predicted to vary inversely with the stirrer speed, as confirmed in various studies [15,16,17,18]. Figure 7-16 shows plots of mixing time (tN) against the Reynolds number NRe for several systems. As an example, a turbine with DA/DT = 1/3 and DT/H = 1, the value of Nt is 36, for NRe > 103, compared with a predicted value of 38. Table 7-5 Methods for determining blending time Technique
Tracer
Blend time reached when
Grab sample
Any material that can be analyzed.
Samples do not vary more than ±X% from final concentration.
Dye introduction
Dyed fluid.
Uniform color is attained.
Conductivity cell
Concentration of salt solution.
Measured conductivity that represents concentration is within ±X% of final concentration.
Acid-base indicator
Acid (or base).
Neutralization is complete as determined by color change of indicator.
Source: Dickey, D. S., “Dimensional analysis for fluid agitation system,” Chem. Eng., January 5, 1976.
Fluid Mixing in Reactors
579
Figure 7-16. Mixing times in agitated vessels. Dashed lines represent unbaffled tanks; solid lines represents a baffled tank. (Source: McCabe, W. L., et al., Unit Operations of Chemical Engineering, 4th ed., McGraw-Hill Book Company, New York, 1985.)
Prochazka and Landau [19] developed a mixing time correlation for a single Rushton turbine impeller in a baffled tank in the standard configuration for NRe > 104: D Nt = 0.905 T DA
2.57
X log o Xc
(7-25)
For a propeller, the mixing time is given by: D Nt = 3.48 T DA
2.05
X log o Xc
(7-26)
For a pitched-blade turbine, the mixing time is:
D Nt = 2.02 T DA
2.20
X log o Xc
(7-27)
580
Modeling of Chemical Kinetics and Reactor Design
where Xo = initial value of the degree of inhomogeneity, which varies between 1 and 3; a value of 2 is recommended Xc = final integral mean value of the local degree of inhomogeneity and is defined as: C( t ) − C x Xc = Cx − Ci
(7-28)
where C(t) = instantaneous concentration Ci = initial concentration Cx = final concentration Xc = 0.05 for most configurations. Moo-Young et al. [20] correlated their mixing results from Nt = KN aRe
(7-29)
where K = 36 and a = 0 for turbines in baffled tanks for 1,000 < NRe < 105. Sano and Usui [21] developed an expression for mixing times by tracer injection for turbines as: D Nt = 3.8 A DT
−1.80
W DT
−0.51
n P−0.47
(7-30)
where nP is the number of blades. Gray [22] found the mixing times of helical ribbon impellers to be of the form Nt = 30
(7-31)
where N is the rotational speed of the helical ribbon impeller, and t is the batch mixing time. Fasano et al. [23] expressed the blend time for turbulence conditions in a standard baffled tank (i.e., NRe > 10,000) as: t 99 =
4.065 b
D D 0.5 a N A T DT H
(7-32)
Fluid Mixing in Reactors
581
where a and b are the mixing rate constants. Table 7-6 shows values of a and b for different impeller types. The constants are for surface addition, however, blend times for similar fluids are relatively insensitive to addition location. Equation 7-32 is limited to the following: • Newtonian fluids of nearly the same viscosity and density as the bulk fluid. • Additions of 5% or less, of the fluid volume. • Additions made to a vessel already undergoing agitation (blend times of stratified fluids can be considerably longer). The estimated blend time for 95% uniformity (tb,95%) using a standard double flight helical ribbon impeller with (Pi/DA = 1, W/DA = 0.1, and DA/DT = 0.96) is given by For NRe ≤ 100: t b, 95% =
75 N
(7-33)
For anchor impellers of standard geometry (W/DA = 0.1, DA/DT = 0.98, and H/DT = 1.0), the estimated tb for 100 < NRe < 10,000 is given by t b, 95% = exp(12.9 N −Re0.135 ) where DA DT H N
= = = =
(7-34)
impeller diameter, m tank diameter, m impeller or helix height, m impeller rotational speed, sec–1 Table 7-6 Mixing rate constants for fully turbulent flow regimes (NRe > 10,000)
Impeller type
a
b
Six-bladed disc Four-bladed flat Four-bladed 45° pitched Three-bladed high-efficiency
1.06 1.01 0.641 0.272
2.17 2.30 2.19 1.67
Source: Fasano et al. [13], “Advanced Impeller Geometry Boosts Liquid Agitation,” Chem. Eng., 102 (8), August 1994.
582
Modeling of Chemical Kinetics and Reactor Design
Pi = pitch of a helical ribbon impeller, m W = blade width, m Bakker and Gates [23] compared both Equations 7-33 and 7-34 and inferred that at a Reynolds number of 100, it will take an anchor impeller more than 13 times as long to achieve 95% uniformity as a helical ribbon impeller operating at the same speed. These impellers require cooling to remove the excess heat due to their high power input. The mixing time that was considered relates to tanks operating in closed systems (e.g., batch reactors). In a continuous feed tank, the mixing time is generally shorter than in a closed tank. Example 7-1
Calculate the power for agitation of a liquid of density 950 kg/m3 and viscosity 250 cP given the following configuration: number of blades B = 6, agitator diameter 0.61 m, and speed at 90 rpm. Other geometrical ratios are shown in Figure 7-1. A disc-mounted flat turbine is used. Solution The Reynolds number for mixing is N Re =
ρND 2A µ
N = the number of revolutions per sec is (90/60) = 1.5 rev/sec.
N Re =
1 m2 • 3• kg m sec m • sec
(950)(1.5)(0.612 ) kg 250 × 10 −3
NRe = 2,121 Using curve 6 in Figure 7-14, the Power number is NP = 5.0. The theoretical power for mixing is
Fluid Mixing in Reactors
P = N P ρN 3D 5A = 5.0 × 950 × 1.53 × 0.615
583
kg rev3 • m5 3• 3 m sec
= 1,353.99 W = 1.35 kW (1.82 hp) (NB: 1 kW = 1.341 hp) An Excel spreadsheet program (Example 7-1.xls) was developed to determine the theoretical power of any agitator type with given fluid physical properties and tank geometry. Example 7-2
Calculate the theoretical power for a six-blade, flat-blade turbine without baffles, but with the standard tank configuration shown in Table 7-2. Use the same data as in Example 7-1. Solution Since the tank is unbaffled, the Froude number is a factor and its effect is calculated from
N Fr
2 N 2 D A (1.5 )(0.61) = = g 9.81
rev m 2• m sec sec 2
= 0.14 N Re = 2,121
The constants a and b for an unbaffled tank R = 0, are a = 1.0 and b = 40. Using curve 5 in Figure 7-14, the Power number is NP = 2.0
Nm Fr where m =
a − log10 N Re b
584
m=
Modeling of Chemical Kinetics and Reactor Design
1.0 − log10 2,121 = − 0.0582 40
−0.0582 Nm = 1.1212 Fr = 0.14
Therefore, power P = N P ρN 3D 5A N m Fr kg rev3 = 2.0 × 950 × 1.53 × 0.615 × 1.1212 3 • • m5 3 m sec
= 607.24 W = 0.61 kW (0.81 hp) A Microsoft Excel spreadsheet (Example7-2.xls) was developed for an unbaffled tank. Studies on various turbine agitators have shown that geometric ratios that vary from the standard design can cause different effects on the Power number NP in the turbulent regions [24]. • For the flat, six-blade open turbine, NP ∝ (W/DA)1.0. • For the flat, six-blade open turbine, varying DA/DT from 0.25 to 0.5 has no effect on NP. • When two six-blade open turbines are installed on the same shaft and the spacing between the two impellers (vertical distance between the bottom edges of the two turbines) is at least equal to DA, the total power is 1.9 times a single flat-blade impeller. For two six-blade pitched-blade (45°) turbines, the power is about 1.9 times that of a single pitched-blade impeller. • A baffled, vertical square tank or a horizontal cylindrical tank has the same Power number as a vertical cylindrical tank.
SCALE-UP OF MIXING SYSTEMS The calculation of power requirements for agitation is only a part of the mixer design. In any mixing problem, there are several defined objectives such as the time required for blending two immiscible liquids, rates of heat transfer from a heated jacket per unit volume of the agitated liquid, and mass transfer rate from gas bubbles dispersed by agitation in a liquid. For all these objectives, the process results are to achieve the optimum mixing and uniform blending.
Fluid Mixing in Reactors
585
The process results are related to variables characterizing mixing, namely geometric dimensions, stirrer speed (rpm), agitator power, and physical properties of the fluid (e.g., density, viscosity, and surface tension) or their dimensionsless combinations (e.g., the Reynolds number, Froude number, and Weber number, ρN2D3A/σ). Sometimes, empirical relationships are established to relate process results and agitation parameters. Often, however, such relationships are nonexistent. Laboratory scales of equipment using the same materials as on a large scale are then experimented with, and the desired process result is obtained. The laboratory system can then be scaled-up to predict the conditions on the larger system. For some scale-up problems, generalized correlations as shown in Figures 7-11, 7-12, 7-13, and 7-14 are available for scale-up. However, there is much diversity in the process to be scaled-up, and as such no single method can successfully handle all types of scale-up problems. Various methods of scale-up have been proposed; all based on geometric similarity between the laboratory equipment and the fullscale plant. It is not always possible to have the large and small vessels geometrically similar, although it is perhaps the simplest to attain. If geometric similarity is achievable, dynamic and kinematic similarity cannot often be predicted at the same time. For these reasons, experience and judgment are relied on with aspects to scale-up. The main objectives in a fluid agitation process are [25]: • Equivalent liquid motion (e.g., liquid blending where the liquid motion or corresponding velocities are approximately the same in both cases). • Equivalent suspension of solids, where the levels of suspension are identical. • Equivalent rates of mass transfer, where mass transfer is occurring between a liquid and a solid phase, between liquid-liquid phases, or between gas and liquid phases, and the rates are identical. A scale ratio R is used for scale-up from the standard configuration as shown in Table 7-2. The procedure is: 1. Determine the scale-up ratio R, assuming that the original vessel is a standard cylinder with DT1 = H1. The volume V1 is V1 =
πD 2T1 πD3T1 • H1 = 4 4
(7-35)
586
Modeling of Chemical Kinetics and Reactor Design
The ratio of the volumes is then V2 πD3T 2 4 D3 = = T3 2 3 V1 πD T1 4 D T1
(7-36)
The scale-up ratio R is 1
R=
DT2 D T1
V 3 = T2 VT1
(7-37)
Using the value of R, calculate the new dimensions for all geometric sizes. That is, DA2 = RDA1, J2 = RJ1, W2 = RW1 E2 = RE1, L2 = RL1, H2 = RH1 or
R=
D A 2 D T 2 W2 H 2 J 2 E 2 = = = = = D A1 D T1 W1 H1 J1 E1
2. The selected scale-up rule is applied to determine the agitator speed N2 from the equation:
D 1 n N 2 = N1 = N1 T1 R DT2
n
(7-38)
• where n = 1 for equal liquid motion • n = 3/4 for equal suspension of solids • n = 2/3 for equal rates of mass transfer (corresponding equivalent power per unit volume, which results in equivalent interfacial area per unit volume) The value of n is based on theoretical and empirical considerations and depends on the type of agitation problem. 3. Knowing the value of N2, the required power can be determined using Equation 7-17 and the generalized Power number correlation.
Fluid Mixing in Reactors
587
Other possible ways of scaling up are constant tip speed uT(πNDA), and a constant ratio of circulating capacity to head Q/h. Since P ∝ N3D5A and V ∝ D3A then P ∝ N 3D 2A V
(7-39)
For scale-up from system 1 to system 2 involving geometrically similar tanks and same liquid properties, the following equations can be applied: N1DA1 = N2DA2 For a constant tip speed, N2 D = A1 N1 D A 2
(7-40)
For a constant ratio of circulating capacity to head, Q/h, N13 D 2A1 = N 32 D 2A 2
(7-41)
Example 7-3
Scraper blades set to rotate at 35 rpm are used for a pilot plant addition of liquid ingredients into a body-wash product. What should the speed of the blades be in a full-scale plant, if the pilot and the full-scale plants are geometrically similar in design? Assume scaleup is based on constant tip speed, diameter of the pilot plant scraper blades is 0.6 m, and diameter of the full-scale plant scraper blades is 8 ft. Solution The diameter of the full scale plant scraper blades = 8.0 × 0.3048 = 2.4384 m (2.4 m). Assuming constant tip speed, N2 D = A1 N1 D A 2
(7-42)
588
Modeling of Chemical Kinetics and Reactor Design
where N1 N2 DA1 DA2 N2 = =
= = = =
scraper speed of pilot plant scraper speed of full-scale plant diameter of pilot plant scraper blades diameter of full-scale plant scraper blades
N1 D A1 DA2
(35) (0.6) (2.4)
= 8.75 rpm
Example 7-4
During liquid makeup production, color pigments (i.e., solid having identical particle size) are added to the product via a mixer. In the pilot plant, this mixer runs at 6,700 rpm and has a diameter head of 0.035 m. Full-scale production is geometrically similar and has a mixer head diameter of 0.12 m. Determine the speed of the full-scale production mixer head. What additional information is required for the motor to drive this mixer? Assume that power curves are available for this mixer design, and the scale-up basis is constant power/unit volume. Solution For constant power per unit volume, Equation 7-39 is applied: P/V ∝ N3D2A or N13D2A1 = N23D2A2. Therefore,
D N 2 = N1 A1 DA2
23
where N1 = 6,700 rpm DA1 = 0.035 m DA2 = 0.12 m 0.035 N 2 = 6, 700 0.12
23
Fluid Mixing in Reactors
589
N2 = 2,946.7 rpm N2 ≈ 2,950 rpm The power required for mixing is P = NpρN3D5A, where the Power number (NP) is a function of the Reynolds number [i.e., NP = f(NRe)]: N Re =
ρND 2A µ
The plant must be provided with the viscosity of the product and its density after addition of the pigments.
Example 7-5
A turbine agitator with six flat blades and a disk has a diameter of 0.203 m. It is used in a tank with a diameter of 0.61 m and height of 0.61 m. The width is W = 0.0405 m. Four baffles are used with a width of 0.051 m. The turbine operates at 275 rpm in a liquid having a density of 909 kg/m3 and viscosity of 0.02 Pas. Calculate the kW power of the turbine and kW/m3 of volume. Scale up this system to a vessel whose volume is four times as large, for the case of equal mass transfer rate. Solution The Reynolds number for mixing is NRe. The number of revolutions per sec, N = 275/60 = 4.58 rev/sec.
N Re = =
ρND 2A µ
(909)(4.58)(0.203)2 kg rev 2 m • sec •m • 3 •
= 8, 578.1 NRe ≈ 8,600
0.02
m
sec
kg
590
Modeling of Chemical Kinetics and Reactor Design
Using curve 6 in Figure 7-14, the Power number NP = 6.0. The power of the turbine P = NpρN3D5A:
kg rev3 • m5 P = (6.0)(909)(4.583)(0.2035) 3 • 3 m sec = 0.1806 kW (0.24 hp) The original tank volume V1 = πD3T1/4. The tank diameter DT1 = 0.61:
V1 =
( π)(0.61)3 4
V1 = 0.178m3 The power per unit volume is P/V P 0.1806 = V 0.178 = 1.014 kW/m 3
For the scale-up of the system, the scale-up ratio R is
R=
V2 πD3T 2 4 D3T 2 = = V1 D3T1 πD3T1 4 1
V 3 D R = 2 = T2 D T1 V1
where V2 = 4V1
V2 = 4 (0.178) = 0.712 m 3 1
R = ( 4) 3 = 1.587
(7-37)
Fluid Mixing in Reactors
591
The dimensions of the larger agitator and tank are: DA2 = RDA1 = 1.587 × 0.203 = 0.322 m DT2 = RDT1 = 1.587 × 0.61 = 0.968 m For equal mass transfer rate n = 2/3. 2
1 3 N 2 = N1 R
(7-38)
2
1 3 = 4.58 1.587
= 3.37 rev/sec The Reynolds number NRe is N Re =
=
ρN 2 D 2A 2 µ
(909)(3.37)(0.322)2 kg rev 2 m • sec •m • 3 • 0.02
m
sec
kg
= 15,880.9 NRe ≈ 16,000 Using curve 6 in Figure 7-14, NP = 6.0. Power required by the agitator is P2 = NpρN23D5A2 P2 = (6.0)(909)(3.37)3 (0.322)5
P2 = 722.57 W = 0.723 kW (0.97 hp)
kg rev3 • m5 3• 3 sec m
592
Modeling of Chemical Kinetics and Reactor Design
The power per unit volume P/V is:
P2 0.723 = V2 0.712 = 1.015 kW/m3 A Microsoft Excel spreadsheet (Example 7-5.xls) was developed for this example. MIXING TIME SCALE-UP Predicting the time for obtaining concentration uniformity in a batch mixing operation can be based on model theory. Using the appropriate dimensionless groups of the pertinent variables, a relationship can be developed between mixing times in the model and large-scale systems for geometrically similar equipment. Consider the mixing in both small and large-scale systems to occur in the turbulent region, designated as S and L respectively. Using the Norwood and Metzner’s correlation [26], the mixing time for both systems is t S ( N SD 2AS )
23 16
g D1AS2
H1S 2 • D3TS2
=
t L ( N L D 2AL )
23 16
g D1AL2
H1L 2 • D3TL2
(7-43)
Applying the scale-up rule of equal mixing times, and rearranging Equation 7-43, yields 2
3
4
1
1
N L 3 D TL 2 D AS 3 D AS 2 H L 2 = NS D TS D AL D AL H S
(7-44)
Assuming geometric similarity,
HL D = AL HS D AS
(7-45)
D TL D = AL D TS D AS
(7-46)
Fluid Mixing in Reactors
593
Substituting Equations 7-45 and 7-46 into Equation 7-44 gives 2
3
4
1
1
N L 3 D AL 2 D AS 3 D AS 2 D AL 2 = NS D AS D AL D AL D AS 2
(7-47)
1
NL 3 D AL 6 = NS D AS
or 1
NL D AL 4 = NS D AS
(7-48)
The exponent n for the mixing time scale-up rule is 0.25. The power P of the agitator for both large and small systems is
PL 3 5 ρN L D AL
PS ρN 3SD 5AS
=
(7-49)
where 3
PL N L D AL = PS N S D AS
5
(7-50)
Substituting Equation 7-48 into Equation 7-50 yields PL D AL = PS D AS
0.75
PL D AL = PS D AS
5.75
D AL D AS
5
(7-51)
or
(7-52)
594
Modeling of Chemical Kinetics and Reactor Design
The power per unit volume P/V for both large- and small-scale systems is:
PL VL = PS VS
PL PS
P = L PS
πD3TL 4 πD3TS 4 D • TS D TL
3
(7-53)
Substituting Equations 7-46 and 7-52 into Equation 7-53 gives
( P V)L ( P V )S
D = AL D AS D = AL D AS
5.75
D AS D AL
3
2.75
(7-54)
Table 7-7 summarizes correlations for the effects of equipment size on the rotational speed needed for the same mixing time by various investigators. The relationships in Table 7-7 show that the rotational speed to obtain the same batch mixing time is changed by a small power of the increase in linear equipment dimension as equipment size is changed. Equation 7-49 shows that greater power is required for a large-scale system compared to a smaller system. Often, the power required for a larger system may be prohibitive, thus modification of the scale-up rule is needed (e.g., t L = 10t S or t L = 100t S) to obtain a lower power requirement. It should be noted that relaxation of mixing time requirements may not pose other problems. For example, if the mixing is accompanied by a chemical reaction in a CSTR, assuming that the Norwood-Metzner [26] correlation for mixing time (t) is still applicable, it must be ensured that the mixing time in the larger scale (tL = 10tS or tL = 100tS) is less than 5% of the average residence time of the liquids in the reactor, otherwise the conversion
Propellers Turbines
N ∝ D–1/5
N ∝ D1/4 Zero
Zero
Zero
Not zero
Not zero
∆ρ
θ=
(
N1Re6 ND 2
)
g
−0.3
0.25
46 16
C1Z1L 2 T
2 2 θQ ∝ ρD N V gZ L ∆ρ
θND 2 p ρD 2 N 2 V gZ L ∆ρ
Equation =9
Source: Gray, J. B., Mixing I Theory and Practice, V. W. Uhl and J. B. Gray, Eds. Academic Press Inc., 1966.
Propellers, paddles, turbines
N = constant
Paddles, turbines
N ∝ D–0.1 to –0.2
Propellers, no baffles
Equipment
N ∝ D–1/6
Relationship between N and D
Norwood and Metzner [26]
Fox and Gex [18]
van de Vusse(17)
van de Vusse [17]
van de Vusse [17]
Investigator
Table 7-7 Effect of equipment size on rotational speed needed for the same mixing time
Fluid Mixing in Reactors 595
596
Modeling of Chemical Kinetics and Reactor Design
and product distribution will be affected [27]. Figure 7-17 summarizes the scale-up relationships for many of the important and controlling functions, depending on the nature of the process equipment. The figure identifies which curves apply to laminar (L) and turbulent (T) flow patterns in the fluid being subjected to the mixing operation. The
Figure 7-17. Mixing scale-up factors referenced to experienced ratios of power per unit volume. (Source: Penny, W. R., Chem. Engr., p. 88, March 22, 1971.)
Fluid Mixing in Reactors
597
scale-up chart only applies to systems of similar geometry. When the geometry is different, special and specific analyses of the system are required. Samant and Ng [28] compared various scale-up rules for agitated reactors. They suggested that a scale-up rule of power per unit volume and constant average residence time (where the power per unit volume and average residence time cannot be increased) is the most suited in many operations. However, this still may not improve or preserve the performance of the systems. Therefore, adequate consideration must be given to a tradeoff between performance and operating constraints.
STATIC MIXERS Generally, static or motionless mixers are tubular devices in which mixing elements are inserted in the line through which fluid is pumped. The mixing units or elements are often installed in a circular arrangement; however, they can be adapted to rectangular or other arrangements. The pressure drop incurred as the process stream flows through the mixing elements provides the energy required for the mixing. Pressure drop through the units varies depending on design and whether the flow is laminar or turbulent. A typical static mixer consists of stationary mixing elements, aligned in series and turned on their main axis by 90°. They split the fluid flow into several partial flows. These partial flows are then redirected and recombined to form a mixture, which is homogeneous with respect to concentration and temperature. Mixing in the elements occurs through a combination of flow-splitting and shearing at the junction of successive elements employing a stretching and folding mechanism within the elements. The degree of homogeneity as well as the pressure drop increases with the number of mixing elements. Various types of static mixers are used in the chemical process industry [29]. Table 7-8 lists their wide range of applications. The type of static mixer used often plays an essential role in the mixing mechanism, which greatly affects the flow pattern and pressure drop (∆P) of fluids. The most common mixers are Kenics, Koch, Sulzer SMX, and Ross LPD. The Kenics and Ross LPD have a light structure. They can be employed for low-viscosity fluids in the transient and turbulent flow regimes with relatively low ∆P. The Sulzer SMX is suitable for viscous and non-Newtonian fluids in the laminar flow regime. However, a high ∆P is required to overcome the fluid drag.
598
Modeling of Chemical Kinetics and Reactor Design
Table 7-8 Application of static mixers in the chemical process industry Industry
Applications
Chemicals
Chlorination and oxidation Steam injection Acid and base dilution Fast reactions
Food Processing
Acid washing of fats and oils Constituent blending Starch slurry and cooking
Mineral Processing
Slurry dilution Metal recovery by solvent extraction
Paints and Resins
Coloring and tinting Solvent blending Emissions monitoring and control
Petrochemicals and Refining
Gaseous reactant blending Gasoline blending Emissions monitoring and control
Pharmaceuticals
Nutrient blending Sterilization pH control
Polymers and Plastics
Reactant/catalyst blending Thermal homogenization Plug-flow finishing reactors
Pulp and Paper
Chemical and coatings preparation Stock dilution and consistency control Addition of bleaching chemicals
Water and Waste Treatment
Polymer dilution Disinfection, aeration, and dechlorination
Source: Myers, K. J., et al., Chem. Eng. Prog., June 1997. Reproduced with permission of AIChEJ. © Copyright 1997. All rights reserved.
The Kenics static mixer provides continuous inline mixing and processing, has no moving parts, and requires no external power or regular maintenance. Static mixers have proven to be effective for many process applications. Although useful for a wide range of viscosity fluids, some of the units have given excellent performance in the mixing of molten polymers. This type of unit is particularly
Fluid Mixing in Reactors
599
useful in liquid-liquid mixing; some units can be designed for solidliquid dispersion, gas-gas, and gas-liquid mixing/dispersion. Static mixers are used for laminar, transitional, and turbulent blending of miscible liquids, as tubular reactors in laminar flow heat exchangers, for laminar and turbulent homogenization, for dispersion of immiscible phases, and for interphase mass transfer between immiscible phases. When two immiscible fluids are subjected to the shear forces within a specific number of Kenics mixer units, drops of one phase are produced within the other. Intimate contact between the two fluids is achieved because of the mixing characteristics. An average drop size is established for a given flowrate and depends on the diameter of the mixer, the average linear velocity, the geometry of the mixer elements, and the physical properties of the two fluids. Drop size significantly effects the stability of a dispersed system, and dimensional analysis shows that the drop size of the dispersed phase is controlled by the Weber number (NWe), defined as: N We =
where ρ D v σ
ρv 2 D σ
= = = =
density of fluid inside tube diameter average axial velocity in the mixer interfacial surface tension
Some units can be adapted for solid-solid blending. The residence time in the units can be varied or adjusted, which makes them suitable for certain types of reactions. Figure 7-18 shows a cross-section of a flanged Kenics static mixer with four helical mixing elements, and Table 7-9 lists the characteristics of static mixers. PRINCIPLES OF OPERATION The Kenics static mixer unit is a series of fixed, helical elements enclosed within a tubular housing. The fixed geometric design of the unit produces the following unique patterns of flow division and radial mixing simultaneously. In laminar flow, a processed material divides at the leading edge of each element and follows the channels created by the element shape. At each succeeding element, the two channels are further divided, resulting in an exponential increase in stratification.
600
Modeling of Chemical Kinetics and Reactor Design
Figure 7-18. Cross-section of flanged Kenics Static Mixer with four helical mixing elements. (Source: Chemineer-Liquid-Agitation.)
Table 7-9 Advantages of static mixers • • • • • • • • • • •
No moving parts Little or no maintenance requirements Small space requirements Available in many construction materials No power requirements other than pumping Mixing achieved in short conduit lengths Minimal chance of material hangup or plugging Short residence times Narrow residence time distribution Enhanced heat transfer Cost effective
Source: Myers, K. J., et al., Chem. Eng. Prog., June 1997. Reproduced with permission of AIChEJ. © Copyright 1997. All rights reserved.
The number of striations produced is 2n, where n is the number of elements (Figure 7-19). RADIAL MIXING In either laminar or turbulent flow, rotational circulation of a processed material around its own hydraulic center in each channel of the mixer causes radial mixing of the material. All processed material is continuously and completely intermixed, virtually eliminating radial gradients in temperature, velocity, and material composition.
Fluid Mixing in Reactors
601
Figure 7-19. Principles of operation of static mixer modules.
The HEV static mixer produces complete stream uniformity through controlled vortex structures generated by the mixing elements. The element geometry takes advantage of the naturally occurring vortices induced by the element edges. These principles result in a reliable scale-up. Generally, the Kenics static mixer maximizes efficiency without the wasted energy and material blockage that occur in other restrictive motionless mixers. The pressure drop in the Kenics mixer of the same length and diameter as an empty pipe can be determined from ∆PSM = K • ∆P
(7-55)
where ∆P SM is the pressure drop in the Kenics mixer and K is a function of the geometry of the mixer elements and the Reynolds number. The value for K is determined from Figures 7-20 and 7-21 depending on the type of flow regimes. Table 7-10 shows the Kenics mixer specification parameters for varying pipe sizes. (text continued on page 604)
602
Modeling of Chemical Kinetics and Reactor Design
Figure 7-20. A-factor versus Reynolds number in the laminar flow region 10 < NRe < 2,000. (Source: Chen, S. J., Kenics technical data KTEK-2, 1978.)
Figure 7-21. B-factor versus Reynolds number in the turbulent regions. (Source: Chen, S. J., Kenics technical data KTEK-2, 1978.)
Table 7-10 Kenics mixer specification
Fluid Mixing in Reactors 603
604
Modeling of Chemical Kinetics and Reactor Design
Because there are no moving parts in the Kenics mixer, only the processed materials are in motion. Therefore, the only energy required for the mixer is the energy required to overcome the pressure drop (∆P). The general equation for calculating the pressure drop in an empty pipe for isothermal incompressible fluids is given by L ρv 2 ∆P = 4 fF DSM 2g c
(7-56)
For laminar flow (i.e., NRe < 2,000), ∆P is given by L µW −4 L ∆P = 3.4 × 10 −5 4 = 2.73 × 10 4 (µQ) DSM DSM ρ
(7-57)
∆P in S.I. unit is: L L µW ∆P = 113.2 4 = 6.79 4 (µρ) DSM DSM ρ
(7-58)
For turbulent flow, ∆P is given by L L W2 ∆P = 2.16 × 10 −4 fD 5 ρQ 2 = 3.36 × 10 −6 fD 5 (7-59) DSM DSM ρ ∆P in S.I. unit is: L L W2 ∆P = 2.252 fD 5 ρQ 2 = 625.3 fD 5 DSM DSM ρ where ∆P ρ fD L v gC
= = = = = =
(7-60)
pressure drop in a pipe (psi, bar) fluid density (lb/ft3, kg/m3) Darcy friction factor (fD = 4fF) length of a static mixer (ft, m) fluid velocity (ft/sec, m/sec) dimensional gravitational constant (32.714 lbm/lbf • ft/sec2, 1 kg • m/N • sec2)
Fluid Mixing in Reactors
605
DSM = inside diameter of a static mixer (in, mm) Q = volumetric flowrate (U.S. gal/min, l/min) W = mass flowrate (lb/hr, kg/hr) The Reynolds number NRe is determined by N Re = 50.6
Q •ρ W = 6.31 µ • DSM µ • DSM
(7-61)
For S.I. unit, NRe is determined by
N Re = 21.22
Q •ρ W = 354 µ • DSM µ • DSM
(7-62)
where µ is the fluid viscosity, cP. For 0 < NRe <2,000, the friction factor is
fD =
64 N Re
(7-63)
At higher Reynolds numbers, the friction factor is affected by the roughness of the surface, measured as the ratio ε/D of projections on the surface to the diameter of the pipe. Glass and plastic pipe essentially have ε = 0. Table 7-11 gives the pipe roughness of various materials. Figure 7-22 shows plots of Darcy friction factor versus Reynolds number for various pipe sizes. Alternatively, an explicit equation for the friction factor is given by [30]: Table 7-11 Pipe roughness of materials Material
Pipe roughness ε(ft)
Pipe roughness ε(mm)
Riveted steel Cast iron Galvanized iron Asphalted cast iron Commercial steel or wrought iron Drawn tubing
0.003–0.03 0.00085 0.0005 0.0004 0.00015 0.000005
0.9–9.0 0.25 0.15 0.12 0.046 0.0015
606
Modeling of Chemical Kinetics and Reactor Design
Figure 7-22. Friction factor chart for various pipe sizes.
ε DSM 5.02 1 = − 4 log − log A fC N Re 3.7
(7-64)
where A = (ε/DSM)/3.7 + (6.7/NRe)0.9 fC = Chen friction factor ε = pipe roughness A more explicit equation is given by [31]: f = 1.6364 ln
0.135 ε 6.5 + N Re DSM
−2
(7-65)
The Darcy friction factor fD is four times the Fanning (fF) friction factor (i.e., fD = 4fF = fC). TWO-PHASE FLOW PRESSURE DROP (GAS-LIQUID) ESTIMATION The Lockhart and Martinelli [32] correlation is employed to estimate the two-phase pressure drop in the Kenics mixer. The pressure drop
Fluid Mixing in Reactors
607
is calculated for each phase, assuming that each phase is flowing alone in the unit. The pressure drop for each phase is related to the X-factor defined by ∆P X= L ∆PG
0.5
(7-66)
where X = a factor (dimensionless) ∆PL = pressure drop of liquid phase only (psi/element) ∆PG = pressure drop of gas phase only (psi/element) The two-phase pressure drop is obtained by multiplying either the liquid-phase drop by φ2L or the gas-phase pressure drop by φ2G . Figure 7-23 gives the Lockhart-Martinelli correlation between X and φ’s where φLTT = liquid-phase pressure drop correction factor with both phases in turbulent flow region φLVV = liquid-phase pressure drop correction factor with both phases in viscous (or laminar) flow region
Figure 7-23. Parameters for pressure drop in liquid/gas flow through horizontal pipes. (Source: Lockhead and Martinelli, Chem. Engr. Prog., 45, 39, 1949.)
608
Modeling of Chemical Kinetics and Reactor Design
φGTT = gas-phase pressure drop correction factor with both phases in turbulent flow region φGVV = gas-phase pressure drop correction factor with both phases in viscous (or laminar) flow region The values midway between the TT and VV curves in Figure 7-23 are used for flow systems with either turbulent gas phase and viscous liquid phase or vice versa. The total pressure drop is:
∆P = ∆PL • φ 2L TT or ∆P = ∆PG • φ 2G TT
(7-67)
Coker [33] has developed a computer program to apply the LockhartMartinelli correlation to determine the total pressure drop of the twophase flow based on the vapor phase pressure drop. The program also determines the gas-liquid phase regime employing a modified Baker’s map used to determine the flow regimes for horizontal gas-liquid flow. Static mixers generate smaller gas bubbles than stirred tank reactors (STR) and bubble columns, resulting in improved mass transfer rates 10 to 100 times those of a STR. Recently, a static mixer was successfully employed to enhance gas-liquid mixing and mass transfer in a process intensification of a packed-bed reactor. This resulted in increased productivity, elimination of a gel byproduct in the reactor, thus avoiding the need for frequent shutdown [34]. In most process piping applications, the required Kenics mixer diameter is the same as the existing process line diameter. The K-factor for a specific process application is determined by the Reynolds number as follows [35]: 1. If NRe is less than 10, K = KOL. 2. If NRe is between 10 and 2,000, use Figure 7-20. 3. If NRe is greater than 2,000, use Figure 7-21. Multiply K by the empty-pipe pressure drop to obtain the pressure drop caused by the Kenics mixer model installation. The theoretical horsepower required by the Kenics mixer is determined by hp = (0.262)(∆PSM)(q)
(7-68)
Fluid Mixing in Reactors
609
where ∆PSM = pressure drop in the Kenics Mixer (psi) q = volumetric flowrate (ft3/sec) To design the Kenics Mixer for a blending application, the procedure is as follows: 1. Calculate the Reynolds number (NRe) for the existing process line. 2. Choose the appropriate Standard Model from Table 7-12. 3. Determine the pressure drop (∆P) in the existing process line as a result of Standard Model installation. If ∆P is excessive, repeat steps 1 through 3 using a larger mixer diameter. Li et al. [36] performed an extensive study on ∆P in a Sulzer SMX static mixer with both Newtonian and non-Newtonian fluids. They showed that ∆P increased by a factor of 23 in a SMX static mixer in the laminar flow regime. Figure 7-24 shows their correlation between the Fanning friction factor and the Reynolds number for experimental points under various operating conditions. Computational fluid dynamics (CFD) simulations are a valuable tool in studying the flow and mixing in static mixers [37]. Static mixer technology has been employed to solve many process mixing problems. Additionally, static mixers are used in tubular laminar flow reactors. Laminar open-pipe chemical reactors give a broad residence time distribution (RTD). The residence time distribution (Chapter 8) can be narrowed by the addition of helical elements, thus approaching the ideal plug flow system. The design data and calculations of static
Table 7-12 The correct number of Kenics Mixer models for blending applications NRe (based on empty pipe)
Standard model required
<10 10–100 100–1,000 1,000–5,000 >5,000
18 12 16 14 12
Source: Chen, S. J., Pressure drop in the Kenics mixer: Kenics Technical data KTEK-2, 1988.
610
Modeling of Chemical Kinetics and Reactor Design
Figure 7-24. Friction factor versus Reynolds number in Sulzer SMX Static Mixer. (Source: Li et al., Trans. IChemE, Vol. 75, Part A, pp. 792–798, 1997. Reproduced with permission of the Trans. IChemE.)
mixers can be incorporated into knowledge-based computer programs that produce optimal and cost effective designs for a wide range of applications [38]. Figure 7-25 shows a flowsheet that illustrates the pertinent issues to consider when selecting the proper mixer. Example 7-6
What Kenics Mixer model of 3-in. Schedule 40 is required to process a Newtonian fluid with a viscosity of 150,000 cP, a density of 60 lb/ft3, and a flowrate of 650 lb/hr? What is the pressure drop (∆P) and theoretical horsepower? Solution From Table 7-10, DSM = 3.07 in., KOL = 4.94, K ′OL = 0.052, and KOT = 23.6.
Fluid Mixing in Reactors
611
Figure 7-25. Flowchart shows the main issues in deciding the use of either a static mixer or an agitated tank. (Source: Myers, K., et al., Chem. Eng. Prog., June 1997. Used with permission of AIChE. Copyright © 1997. All rights reserved.)
612
Modeling of Chemical Kinetics and Reactor Design
From Equation 7-61, the Reynolds number is
N Re = 6.31•
= 6.31•
W µDSM
(7-61)
650 5 1 . 5 × 10 ( )(3.07)
= 0.0089(8.9 × 10–3) Because NRe < 10, from Table 7-12 model 18 is required. The Darcy friction factor fD is: fD =
64 64 = N Re (8.9 × 10 −3 )
(7-63)
= 7,185 From Table 7-10, the length of the Kenics mixer model is L = 2.82 ft. Therefore, the length of four modules is (i.e., the length of model 6 mixer = 2.82 ft): 18 L = × 2.82 ft 6
L = 8.46 ft The pressure drop ∆P in the empty tube is: L µW ∆P = 3.4 × 10 −5 4 DSM ρ 8.46 1.5 × 10 5 × 650 = (3.4 × 10 −5 ) 3.07 4 60
= 5.26 psi
(7-57)
Fluid Mixing in Reactors
613
Because NRe < 10, Figure 7-20 gives K = KOL = 4.94. The pressure drop in a model 18 mixer is: ∆PSM = K • ∆P
(7-55)
= 4.94 × 5.26 = 25.98 psi The required theoretical horsepower from Equation 7-68 is: hp = (0.262)(∆PSM)(q)
(7-68)
650 hp = (0.262)(25.98) 60 × 3, 600 = 0.02 hp Example 7-7
Determine which 2-in. Schedule 40 mixer model is required to process water-like fluids at a flowrate of 10 gpm. What is the required theoretical horsepower? (Data: viscosity = 1 cP; Density = 62.4 lbm/ft3; assume ε = 0.00015 ft) Solution From Table 7-10, DSM KOL K ′OL KOT
= = = =
2.07 in. 5.70 0.068 35.1
Using Equation 7-61, the Reynolds number is:
N Re = 50.6
Q•ρ µ • DSM
(7-61)
614
Modeling of Chemical Kinetics and Reactor Design
= 50.6
(10)(62.4) (1) (2.07)
= 15,253.3 (1.5 × 104) Because NRe > 2000, model 2 is required (Table 7-12). The Darcy friction factor fD from Equation 7-64 is fD = 0.0293. The length for model 2 is L = 1.71/3 = 0.57 ft (i.e., the length for model 6 mixer = 1.71 ft). The pressure drop (∆P) in the empty pipe is: L ∆P = 2.16 × 10 −4 fD 5 ρQ 2 DSM
(7-59)
0.57 ∆P = 2.16 × 10 −4 (0.0293) (62.4)(10 2 ) 2.075 = 5.92 × 10–4 psi Because NRe > 2000, from Figure 7-21, B = 1.85 B = 1.85 at NRe = 1.5 × 104 K = KOT × B = 35.1 × 1.85 = 64.94 The pressure drop in the Kenics Mixer is: ∆PSM = K • ∆P
(7-55)
= 64.94 × 5.92 × 10–4 = 0.038 psi The required theoretical horsepower is: hp = (0.262)(∆PSM)(q)
(7-68)
Fluid Mixing in Reactors
= (0.262) (0.038)
615
10 × 0.134 60
= 2.25 × 10–4 hp Example 7-8
A liquid-gas mixture is to flow in a 3-in. Schedule 40 Kenics mixer. Estimate the pressure drop of the unit. The system conditions and physical properties are:
Flowrate, lb/hr Density, lb/ft3 Viscosity, cP Surface tension, dyne/cm
Liquid
Gas
1,000 62.4 1.0 15.0
3,000 0.077 0.00127
The length of 3-in. Schedule 40 pipe from Table 7-8 is 2.82 ft. Assume ε = 0.00015 ft. Solution A computer program (TWOPHASE) was developed that uses the Lockhart-Matinelli correlation and determines the total pressure drop based on the vapor phase pressure drop. The total length of the unit depends on the nature of the Reynolds number. The program also calculates the gas-liquid phase regime employing a modified Baker’s map [33]. Table 7-13 gives the results of the two-phase pressure drop.
HEAT TRANSFER IN AGITATED VESSELS Agitated vessels with an external jacket or an internal coil are increasingly employed in biotechnology and other process applications. The most common type of jackets consists of an outer cylinder that surrounds part of the vessel. The heating or cooling medium circulates in the annular space between the jacket and vessel walls. Alternatively, condensation of vapor (e.g., steam or a proprietary heat transfer medium) may serve for heating and vaporization of liquid (e.g., a refrigerant) may serve for cooling. The heat is transferred through the wall of the vessel. Circulation baffles can be used in the annular space
616
Modeling of Chemical Kinetics and Reactor Design
Table 7-13 Two-phase pressure drop calculation in a pipeline
to increase the velocity of the liquid flowing through the jacket, thus enhancing the heat transfer coefficient. An alternative is to introduce the fluid via a series of nozzles spaced down the jacket. In this case, the momentum of the jets issuing from the nozzles develops a swirling motion in the jacket liquid. The spacing between the jacket and vessel wall depends on the size of the vessel, however, it ranges from 50 mm for small vessels to 300 mm for larger vessels. Figure 7-26 shows different configurations of jacketed vessels. The pitch of the coils and the area covered can be selected to provide the heat transfer area required. Standard pipe sizes from 60 mm to 120 mm outside diameter area are often used. Half-pipe construction can produce a jacket capable of withstanding a higher pressure than conventional jacket design. The rate of heat transfer to or from an agitated liquid mass in a vessel depends on the physical properties of the liquid (e.g., density, viscosity, and specific heat) and of the heating or cooling medium, the vessel geometry, and the degree of agitation. The type and size of the agitator and its location also influence the rate. An agitator is selected on the basis of material properties and the processing required. The heat transfer forms part of a process operation such as suspended
Fluid Mixing in Reactors
617
Figure 7-26. Types of jacket construction.
or dissolving solids, dispersing a gas in a liquid, emulsifying immiscible liquids, or regulating chemical reactions. When processing is controlled by heat transfer variables, a log mean temperature difference (∆TLMTD) and heat transfer surface area will predominate over the agitation variables. Provided it is sufficient to give a homogeneous process fluid temperature, increased agitation can only reduce the inside film resistance, which is one of a number of resistances that determines the overall heat transfer coefficient.
618
Modeling of Chemical Kinetics and Reactor Design
Many jacketed vessels are reactors; the types of exothermic or endothermic effects reviewed in Chapter 6 must then be taken into account. Stirred tank reactors in which an exothermic reaction is performed may involve the removal of substantial amounts of heat from the reacting mixture. Refluxing of a boiling solvent is a common method; the heat of vaporization of the solvent is removed by the reflux condenser, and the condensed solvent is returned to the reactor. Other methods include cooling the walls of the reactor by means of a jacket with a cooling medium, inserting a cooling coil, or using an external heat exchanger with a pump around system. In many applications using jacketed vessels, successive batches of material are heated (or cooled) to a given temperature, and therefore the heat transfer involves an unsteady state process. Proper care is essential in terms of charging, agitation, and adequate cooling of the reactants to prevent the generated heat from subsequently leading to a runaway reaction. This aspect is reviewed in Chapter 12. DESIGN EQUATION Consider a vessel containing an agitated liquid. Heat transfer occurs mainly through forced convection in the liquid, conduction through the vessel wall, and forced convection in the jacket media. The heat flow may be based on the basic film theory equation and can be expressed by Rate =
or
Driving force Resistance
Q ∆T = A 1U
(7-69)
In an idealized situation, the vessel and its jacket each operate continuously under isothermal conditions. Rearranging Equation 7-69 becomes: Q = UA∆T
(7-70)
In a realistic continuous situation, where the vessel contents are at constant temperature, but with different jacket inlet and outlet temperatures, Equation 7-70 is expressed as:
Fluid Mixing in Reactors
Q = UA∆TLMTD
619
(7-71)
where ∆TLMTD is the log mean temperature difference between the bulk temperature of the vessel contents, t, and the temperature in the jacket, T. ∆TLMTD is expressed as ∆TLMTD =
where t1 t2 T1 T2
= = = =
(t 2 − T2 ) − (t1 − T1 ) ln [( t 2 − T2 ) ( t1 − T1 )]
(7-72)
entering fluid temperature in the vessel leaving fluid temperature in the vessel entering fluid temperature in the jacket leaving fluid temperature in the jacket
The overall heat transfer coefficient U is determined from a series of resistances to the transfer of heat, namely x 1 1 1 = + FFi + w + FFj + U hi k hj
(7-73)
where hi = coefficient on process side of heat transfer area, i.e., inside surface of jacketed vessel or outside surface of internal coil, W/m2°C FFi = fouling factor, inside vessel, m2°C/W xw = wall thickness of vessel or coil, mm k = thermal conductivity, W/m°C FFj = fouling factor, inside jacket, m2°C/W hj = coefficient on inside surface of jacket, W/m2°C When the heat transfer is through internal coils or tubular baffles, the difference between the inner and outer heat transfer surfaces may be significant. Inside Film (hi) Coefficients When applying the following equations for calculating film coefficients in jacketed vessels, the physical property data should be accurate. This is especially important for thermal conductivity k, as its value can have a major impact on the calculated film coefficient and vary widely.
620
Modeling of Chemical Kinetics and Reactor Design
The inside film heat transfer coefficient (hi) can be calculated from the following Nusselt number correlation: c
Nu =
b C N aRe N Pr
µ b DT W , f µ w H DA
(7-74)
where f(DT/H, W/DA) represents various geometric correction factors. For a geometrically similar system, Equation 7-74 becomes: Nu =
C • N aRe
b • N Pr
µb µw
c
(7-75)
For agitated vessels, a
b ρND 2A C p µ µ b h iDT = C kf µ k µw
where hi = DA = DT = N = ρ = kf = CP = µb = µw =
c
(7-76)
heat transfer coefficient to vessel wall or coil, W/m2°C agitator diameter, m tank diameter, m agitator speed (rev/sec) density, kg/m3 thermal conductivity, W/m°C specific heat capacity, J/kg°C viscosity at bulk fluid temperature, [(N•s)/m2][kg/(m•sec)] viscosity at the wall temperature, [(N•s)/m2][kg/(m•sec)]
The values of constant C and the exponents a, b, and c depend on the type of agitator, whether baffles are used and their type, and whether the transfer is via the vessel wall or to coils. Baffles are normally used in most applications, and the values of a, b and c in the literature are 2/3, 1/3, and 0.14 respectively. Tables 7-14 and 7-15 give typical correlations for various agitator types. Fouling Factors and Wall Resistances Experience and judgment as to fouling severity are required to estimate fouling factors (FFi, FFj) to determine the overall heat transfer
Fluid Mixing in Reactors
621
coefficient. These will vary with time and depend on the frequency and efficiency of vessel cleaning. Wall resistances can be significant and should be calculated from accurate thermal conductivity data. Outside Coefficients (ho) Jacketed Vessels Annular Jacket with Spiral Baffling In heat transfer applications, this jacket is considered a helical coil if certain factors are used for calculating outside film coefficients. The equivalent heat transfer diameter, De, for a rectangular cross-section is equal to 4 w (w being the width of the annular space). Velocities are calculated from the actual cross-section of the flow area, pw (p being the pitch of the spiral baffle), and the effective mass flowrate W′ through the passage. The effective mass flowrate is approximately 60% of the total mass flowrate of the jacket. W ′ ≈ 0.6 W
(7-77)
At a given Reynolds number, heat transfer coefficients of coils, particularly with turbulent flow, are higher than those of long, straight pipes, due to friction. This also applies to flow through an annular jacket with spiral baffling. At NRe > 10,000 the Sieder-Tate equation for straight pipe, 1 + 3.5(De/Dc) can be used to calculate the outside film coefficient. h oDe 0.8 0.33 µ = 0.027 ( N Re ) ( N Pr ) b k µw
where De Dc hj µb µw
N Re =
= = = = =
0.14
D e 1 + 3.5 D c
(7-78)
equivalent diameter for heat transfer, mm (ft) Mean or centerline diameter of internal coil helix, mm (ft) heat transfer coefficient on inside surface of jacket viscosity at bulk fluid temperature, [(N•s)/m2][kg/(m•sec)] viscosity at the wall temperature, [(N•s)/m2][kg/(m•sec)]
ρ • v • De µ (text continued on page 628)
Baffled? Yes/No Yes/No Yes/No Yes Yes Yes Yes
Yes
Agitator type
Paddle
Paddle
Flat blade turbine
Flat blade turbine
Flat blade turbine
Propeller
Propeller
Retreating blade turbine No limitation
No limitation
>5,000
2,000< NRE < 700,000
>400
<400
>4,000
20 < NRE < 4,000
Reynolds number (NRE)
(NPr)
0.25
(µb/µw)
0.14
0.33 (NRE)0.67 (NPr)0.33 (µb/µw)0.14
0.54 (NRE)
0.67
0.64 (NRE)0.67 (NPr)0.33 (µb/µw)0.14
Glassed-steel impeller. Three retreating blades. The lower constant (0.33) for the glassed-steel impeller is attributed to greater slippage around its curved surfaces than around the sharp corners of the alloy-steel impeller.
45° pitched, four-blade impeller. Equation is based on limited data with regard to propeller pitch and vessel baffling. Divide hi obtained with this equation by a factor of about 1.3.
Three blades
DA/D T = 1/3, H/D T = 1.0. Sixbladed turbine. Standard geometry.
0.74 (NRE)0.67 (NPr)0.33 (µb/µw)0.14 1.10 (NRE)0.62 (NPr)0.33 (µb/µw)0.14
DA/D T = 1/3, H/D T = 1.0. Sixbladed turbine. Standard geometry.
Vessel geometry is discussed by Holland and Chapman [4]
Remarks
0.54 (NRE)0.67 (NPr)0.33 (µb/µw)0.14
(µb/µw)
0.14
Vessel geometry is discussed by Holland and Chapman [4]
(NPr)
0.33
0.36 (NRE)0.67 (NPr)0.33 (µb/µw)0.14
0.415 (NRE)
0.67
Nusselt number (NNu)
Table 7-14 Equations for calculating inside film coefficients (hi) of jacketed agitated vessels
622 Modeling of Chemical Kinetics and Reactor Design
Yes No Yes
No
No No
No
No
Retreating blade turbine
Retreating blade turbine
Propeller
Anchor
Anchor
Anchor
Helical ribbon
Helical ribbon >130
<130
4,000 < NRE < 37,000
300 < NRE < 4,000
30 < NRE < 300
No limitation
No limitation
No limitation
(µb/µw)
0.248 (NRE)0.67 (NPr)0.33 (µb/µw)0.14 × (i/D)–0.25
× (e/DA)–0.22 (i/D)–0.28
0.248 (NRE)0.5 (NPr)0.33 (µb/µw)0.14
(NPr)
Same as above.
e = clearance, (DT – DA)/2, ft DA = impeller diameter, ft i = agitator-ribbon pitch, ft
Anchor to wall clearance of 1 to 5.125 in. Vessel geometry is illustrated by Holland and Chapman [4]
Similar condition as before.
0.38 (NRE)0.67 (NPr)0.33 (µb/µw)0.18 0.55 (NRE)
The overall heat transfer coefficient U, varies inversely with the anchorto-wall clearance. Anchor to wall clearance is less than 1 in.
1.0 (NRE)0.67 (NPr)0.33 (µb/µw)0.18
0.14
45° pitched four bladed impeller. Equation is based on limited data with regard to propeller pitch and vessel baffling. Divide hi obtained with this equation by a factor of about 1.3.
0.54 (NRE)0.67 (NPr)0.25 (µb/µw)0.14
0.25
Six retreating blades.
0.68 (NRE)0.67 (NPr)0.33 (µb/µw)0.14
0.67
Alloy-steel impeller. Three retreating blades.
0.37 (NRE)0.67 (NPr)0.33 (µb/µw)0.14
Fluid Mixing in Reactors 623
Annular jacket with spiral baffling
Jacket type >10,000
Reynolds number (NRe) Remarks
This jacket is considered a special case of a helical coil if certain factors are incorporated into equations for calculating outside-film coefficients. In the equations at left and below, the equivalent heat transfer diameter De, for a rectangular crosssection is equal to four times the width of the annular space, w and Dc is the mean or centerline diameter of the coil helix. Velocities are calculated from the actual crosssection of the flow area, pw, where p is the pitch of the spiral baffle, and from the effective mass flowrate, W', through the passage. The leakage around spiral baffles is considerable, amounting to 35–50% of the total mass flowrate. The effective mass flowrate is about 60% of the total mass flowrate to the jacket: W′ = 0.6 W. The NNu for this equation should be expressed in terms of De(NNu = hjDe/k) as should the Reynolds number (NRe = Devρ/µ), k being thermal conductivity, v being velocity, and ρ being density.
Nusselt number (NNu) 0.027 (NRe)0.8(NPr)0.33(µb/µw)0.14(1 + 3.5D e/Dc)
Table 7-15 Equations for calculating outside film coefficients (hO) of jacketed agitated vessels
624 Modeling of Chemical Kinetics and Reactor Design
<2,100 2,100
<2,100
Turbulent
Annular jacket with spiral baffling
Annular jacket with spiral baffling
Annular jacket, no baffles
Annular jacket with spiral baffling
Annular jacket, no baffles
Dji and Djo are the inside and outside diameters of the jacket respectively. For this equation, De = Djo – Dji. The Grashof number NGr = De3ρgβ∆tG/µ2 were De is equivalent diameter, g is acceleration due to gravity, β is coefficient of volumetric expansion, µ is viscosity, ρ is density, and ∆tG is the difference between the temperature at the wall and that in the bulk fluid. NGr must be calculated from fluid properties at the bulk temperature. The Nusselt and Reynolds numbers must be calculated with De as the diameter term. For the equivalent heat transfer diameter for turbulent flow, use De = [(Djo)2 – (Dji)2]/Dji, where Dji and Djo are the inside and outside diameters of the jacket respectively. The cross-sectional flow area, Ax = π[(Djo)2 – (Dji)2]/4
1.86(NRe)0.33(NPr)0.33(De/L) 0.33(µb/µw)0.14
0.027(NRe)0.8(NPr)0.33(µb/µw)0.14 × (1 + 3.5De/D c)
Use the above equations depending on the value of NRe
Same as the above. L is length of coil or jacket passage, ft
1.02(NRe)0.45(NPr)0.33(µb/µw)0.14(De/L)0.4 × (Djo/Dji)0.8 (NGr)0.05
1.86 (NRe)0.33(NPr)0.33(De/L)0.33 (µb/µw)0.14
Fluid Mixing in Reactors 625
210 < NRe <10,000 Laminar flow
Turbulent flow Transition flow Laminar flow
Half-pipe coil jacket
Half-pipe coil jacket
Half-pipe coil jacket
Dimple jacket
Reynolds number (NRe)
Annular jacket with spiral baffling
Jacket type
1.86(NRe)0.33(NPr)0.33(De/L) 0.33(µb/µw)0.14
0.027(NRe)0.2(NPr)0.33(µb/µw)0.14 × (1 + 3.5De/Dc)
18.6(NRe)0.33(NPr)0.33(De/L) 0.33(µb/µw)0.14
Nusselt number (NNu)
Table 7-15 (continued)
The equivalent diameter De, in a dimpled jacket equals 0.66 in. the cross-sectional flow area equals 1.98 in.2 per foot of vessel circumference.
Use the above equations depending of the value of NRe.
Dc is the mean diameter of the coil.
When pipe coils are made with a semicircular cross-section, De = πdci/2, where dci is the inner diameter of the pipe, in feet. For calculating the velocity, the crosssectional flow area equals πd2ci/8. When pipe coils are made with a 120° central angle, De = 0.0708 dci and the cross-sectional area equals 0.154(dci)2.
Use the above equations depending on the value of NRe.
Remarks
626 Modeling of Chemical Kinetics and Reactor Design
Transition flow
Dimple jacket
= = = = =
ρVD ρND 2A = µ µ
where µb = viscosity at the bulk fluid temperature µw = viscosity at the wall surface temperature (µb/µw)0.14 ≅ 1.0 for water
Viscosity number, µb/µw
density velocity diameter impeller diameter rotational speed of the agitator µ = viscosity
where ρ V D DA N
Reynolds number, N Re =
The dimensionless parameters:
Turbulent flow
Dimple jacket
= = = =
∆tG =
where De ρ g β
Grashof number, N Gr =
D 3e ρ 2 gβ∆t G µ2 equivalent diameter density acceleration due to gravity coefficient of volumetric expansion difference between the temperature at the wall and that in the bulk fluid
CPµ k where CP = specific heat µ = viscosity k = thermal conductivity Prandtl number, N Pr =
0.27(NRe)0.8(NPr)0.33(µb/µw)0.14
hD k where h = heat transfer coefficient D = diameter k = thermal conductivity Nusselt number, N Nu =
Determine NNu from the above equations depending on the value of NRe.
The coefficients are not very accurate due to turbulence created by the dimples in the flow steam.
Fluid Mixing in Reactors 627
628
Modeling of Chemical Kinetics and Reactor Design
(text continued from page 621)
N Pr =
Cp • µ k
At NRe < 2,100 0.33 µb h oDe 0.33 0.33 D = 1.86 ( N Re ) ( N Pr ) e k L µw
0.14
(7-79)
where L is the length of the coil or jacket passage, mm (ft). Annular Jacket with No Baffles In the case of steam condensation, a film heat transfer coefficient hj is used. In the case of liquid circulation, velocities will be very low because of the large cross-sectional area. Outside heat transfer coefficients for unbaffled jackets under laminar flow conditions can be calculated from, h jD e k
= 1.02 ( N Re ) D jo × D ji
0.45
0.8
(N Pr )
0.33 D e
0.4
L
µb µw
(N Gr )0.05
where Dji = inside diameter of the jacket Djo = outside diameter of the jacket De = Djo – Dji The Grashof number NGr is expressed by
N Gr =
D 2e ρ2 g β∆t G µ 2b
where g = acceleration due to gravity ρ = fluid density
0.14
(7-80)
Fluid Mixing in Reactors
629
β = coefficient of volumetric expansion ∆tG = the difference between the temperature at the wall and that in the bulk fluid µb = viscosity at bulk fluid temperature Evidently, from the low value of the exponent in Equation 7-80, the contribution from natural convection and, hence, its practical significance is small. The following equation can be used to predict heat transfer coefficients from coils to tank walls in agitated tanks. ρND 2A hD T = C kf µ
23
C pµ k
13
µb µw
14
(7-81)
where C is a constant. Table 7-16 gives values of C for various agitator types and surface [39]. A software package (MIXER) was developed to determine the heat transfer coefficient for any type of agitator and surface using the value in Table 7-16, fluid physical properties, agitator speed, and diameter. HEAT TRANSFER AREA Surface area for heating or cooling agitated vessels can be provided by either external jacketing or internal coils (or tubular baffles). Jacketing is usually preferred because of:
Table 7-16 Constant (C) for various impellers Agitator
Surface
C
Turbine Turbine Paddle Paddle Anchor Propeller Propeller
Jacket Coil Jacket Coil Jacket Jacket Coil
0.62 1.50 0.36 0.87 0.46 0.54 0.83
Source: Chopey, N. P. and Hicks, T. G., Handbook of Chemical Engineering Calculations, McGraw-Hill Book Co., 1984.
630
Modeling of Chemical Kinetics and Reactor Design
• Cheaper construction materials because the jacket is not in contact with process fluid. • Less tendency to foul. • Easier cleaning and maintenance. • Fewer problems in circulating catalysts and viscous fluids. • Larger heat-transfer surface, unless significant reactor volume is taken up by the coils. • Helical jackets may allow thinner walls to be used for pressure vessels. • No restriction is placed on agitator type, whereas if a coil is installed it restricts agitator dimensions. Coils should be considered only if jacketing alone does not provide a sufficient heat transfer area, if jacket pressure exceeds 150 psig, or if high-temperature vacuum processing is required. The coil offers the advantage of a higher overall film coefficient because of thinner walls with the latter conditions, but the wall resistance may not be significant compared to that on the process side (e.g., with a viscous liquid). Example 7-9
Determine the heat transfer coefficient from a coil immersed in an agitated vessel with a diameter of 10 ft (3.048 m). The agitator is a paddle measuring 3.5 ft (1.01 m) in diameter and revolving at 200 rev/min. The fluid properties are: ρ = density = 720 kg/m3 µb = viscosity = 4.13 cP = 4.13 × 10–3 (Pa • s) Cp = specific heat = 2.9 kJ/kg • K k = thermal conductivity = 0.17 W/mK Assume (µb/µw)0.14 = 1.0. Solution From Table 7-16, for a paddle type agitator, C = 0.87. The heat transfer coefficient from Equation 7-76 becomes ρND 2A hD T = 0.87 kf µ
23
C pµ k
13
µb µw
14
(7-81)
Fluid Mixing in Reactors
631
N = number of revolution per sec is 200/60 = 3.3333 rev/sec. The Reynolds number, NRe = ρND2A/µ is:
(720)(3.3333)(1.01)2 kg rev m 2 • • N Re = −3 kg 3 4.13 × 10
m
sec
m • sec
= 592,794 The Prandtl number, NPr = Cpµ/k is
N Pr =
(2.9 × 103 ) (4.13 × 10 −3 ) 0.17
J kg sec• m • K • • J kg • K m • sec
= 70.45 The heat transfer coefficient is: 0.17 h v = 0.87 (592, 794)2 3 (70.45)1 3 3.048
h v = 1, 414 W m 2 K Table 7-17 shows the computer results from the MIXER software.
Scale-Up with Heat Transfer The scale-up criterion of constant heat transfer coefficient is suitable when the predominant problem of the reactor involves the removal of heat. The magnitude of the heat transfer coefficient is governed by the intensity of stirring within the reactor, and is represented by: ρND 2A hD T = C k µ
0.65
C pµ k
0.33
µb µw
0.24
(7-82)
where C is a constant that depends on the agitator design and h is the required inside film heat transfer coefficient.
632
Modeling of Chemical Kinetics and Reactor Design
Table 7-17 Heat transfer coefficient to fluids in a vessel using mechanical agitated coils or jacket
To scale-up a reactor from V1 to V 2 with geometrically similar systems having similar bulk average temperatures (i.e., the physical properties of the fluids are identical), Equation 7-82 becomes h 2 D T 2 N 2 D 2A 2 = h1D T1 N1D 2A1
or
h 2DT2 N2 = h1D T1 N1
N2 N1
0.65
0.65
0.65
(7-83)
DA2 D A1
h D D = 2 T 2 A1 h1D T1 D A 2
1.30
(7-84)
1.30
(7-85)
where DT2/DT1 = DA2/DA1. Equation 7-85 becomes N2 N1
0.65
h D D = 2 A 2 A1 h1D A1 D A 2
1.30
At equal heat transfer coefficients, h1 = h2
(7-86)
Fluid Mixing in Reactors
N2 N1
0.65
D = A2 D A1
N D or 2 = A 2 N1 D A1
633
−0.30
(7-87)
−0.46
(7-88)
Assuming that the equation is in the turbulent range, the Power numbers will be equal. The ratio of the power per unit volume (P/V) for large and small scales can be expressed by
( P V )2 (P V)1
=
N 32 D 2A 2 ρN 32 D 5A 2 D3A 2 = N13 D 2A1 ρN13 D 5A1 D3A1
(7-89)
Substituting of Equation 7-88 into Equation 7-89 gives
( P V )2 (P V)1
2
D D = A2 A2 D A1 D A1 D = A2 D A1
−1.38
0.62
(7-90)
The power per unit volume thus increases slightly. For equal heat transfer coefficients on small and large scales, the larger tank will use an impeller at a lower speed.
Where
V2 D T 2 = V1 D T1
N 2 V2 = N1 V1
3
(7-36)
−0.15
(7-91)
Having achieved the same heat transfer coefficient on the larger scale, the heat removal facilities must be increased because the heat
634
Modeling of Chemical Kinetics and Reactor Design
generation is proportional to V2/V1, but the surface area of the vessel has increased by (V2/V1)2/3. This can be done by adding coils in the reactor. Larger areas can be added by using an external heat exchanger and a pump around system. In some cases, it may be possible to lower the coolant temperature and thereby increase the rate of heat flow through the existing surface. However, this is usually fixed by stability considerations, which require that the coolant temperature be within a few degrees of the reaction temperature.
LIQUID–SOLID AGITATION In certain cases, the primary process objective is to keep solid particles in suspension. Areas of application involve catalytic reactions, crystallization, precipitation, ion exchange, and adsorption. Axial flow and pitched-blade turbines are best suited in providing the essential flow patterns in a tank to keep the solids in suspension. The suspended solid is characterized by two parameters: • Particle density, ρP. • Particle size: the mean diameter, d P or the particle size distribution. Various correlations are provided for calculating the minimum speed of the agitator Nmin to keep a given solid in suspension. Zwietering [40] developed the following equation: α
D g 0.45 (ρP − ρL ) µ 0L.1 d P0.2 WS0.13 N min = Ψ T D 0A.85 ρ0L.55 DA where DA DT WS ρL µL
= = = = =
0.45
(7-92)
impeller diameter, m tank diameter, m weight ratio of solid to liquid in percentage liquid density liquid viscosity
Ψ and α depend on the characteristics of the stirrer. For agitator types of propellers, turbines with flat blades and paddles, Ψ and α are 1.5 and 1.4, respectively. The criterion for Equation 7-92 is the absence of any immobile solid on the bottom of the tank.
Fluid Mixing in Reactors
635
Weisman and Efferding [41] in constrast, related the degree of agitation to the height HS occupied by the solid suspension, which is expressed as:
[
H S − E + ( n T − 1) D A
]
DT
where E HS nT V εS ρM uS
= = = = = = =
P (ε )−0.66 D 0.5 S A = 0.23 ln + 0.1 (7-93) n g V u D ρ T M S T
distance from reaction bottom to agitation system height occupied by the solid suspension number of stirring components (1 to 3) volume to be stirred volumetric fraction of solid density of the suspension particle sedimentation rate
Equation 7-93 was established for turbine agitators with flat blades and Z/DA = 0.5. The criteria for Equation 7-93 relate to a specific type of suspension. The distribution of the solid as a function of the height in the liquid is not uniform in every case. Therefore, the uniformity can only be approximated by obtaining a circulation rate Q as high as possible. Nienow [42] found that H/E = 7 in tanks for which H/DT = 1.0. Recently, Corpstein et al. [43] found that high-efficiency impellers provide the same levels of solids suspension at reduced capital and operating costs. They introduced the term “just-suspended” for the most commonly encountered level of liquid solid agitation. This occurs when none of the solid particles remains stationary on the bottom of the vessel for longer than 1–2 sec. They developed a correlation of the speed required to achieve just-suspended conditions as: ρ − ρ N js = k S L u t ρL
0.28
D D f (X) f A T DT Do
−n
(7-94)
where k = applicable coefficient, k = 15.0 for a pitched-blade turbine; k = 23.0 for a high-efficiency impeller Do = a reference scale (0.29 m) DA = impeller diameter, m DT = tank diameter, m
636
Modeling of Chemical Kinetics and Reactor Design
f(X) = solids-loading factor, f(X), is a non-linear function for up to 5% solids loading n = scale-up exponent Njs = just-suspended speed, s–1 ut = terminal settling velocity for a particle, m/sec ρl = density of liquid ρS = density of solids X = solids loading (solids mass/slurry mass) The required power can be determined by: P = N P ρsl N 3D 5A where N NP P ρsl
= = = =
(7-95)
impeller rotation speed, s–1 impeller Power number Impeller power draw, W density of slurry, kg/m3
Computation fluid mixing and computational fluid dynamic techniques have increasingly been used to elucidate solids distribution in agitated vessels [44].
BATCH HEATING AND COOLING OF FLUIDS Heating or cooling of process fluids in a batch-operated vessel is common in the chemical process industries. The process is unsteady state in nature because the heat flow and/or the temperature vary with time at a fixed point. The time required for the heat transfer can be modified, by increasing the agitation of the batch fluid, the rate of circulation of the heat transfer medium in a jacket and/or coil, or the heat transfer area. Bondy and Lippa [45] and Dream [46] have compiled a collection of correlations of heat transfer coefficients in agitated vessels. Batch processes are sometimes disadvantageous because: • • • •
Use of heating or cooling medium is intermittent. The liquid being processed is not readily available. The requirements for treating time require holdup. Cleaning or regeneration is an integral part of the total operating period.
Fluid Mixing in Reactors
637
The variables in batch heating or cooling processes are surface requirement, time, and temperature. Heating a batch may be by external means (e.g., a jacket or coil) or by withdrawing and recirculating process liquid through an external heat exchanger. In either case, assumptions are made to facilitate calculation, namely, • The overall heat transfer coefficient U is constant for the process and over the entire surface. • Liquid flowrates are at steady state. • Specific heats are constant for the process. • The heating or cooling medium has a constant inlet temperature. • Agitation gives a uniform batch fluid temperature. • There is no phase change. • Heat losses are negligible. The following discusses various heating or cooling process conditions in a batch vessel and the processing time relationships. BATCH HEATING: INTERNAL COIL, ISOTHERMAL HEATING MEDIUM When an agitated batch containing M of fluid with specific heat c and initial temperature t is heated using an isothermal condensing heating medium T1, the batch temperature t2 at any time θ can be derived by the differential heat balance. For an unsteady state operation as shown in Figure 7-27, the total number of heat transferred is q′, and per unit time θ is:
I dq =
II dq ′ = dθ
III Mc
dt dθ
Accumulation in the batch
IV =
UA∆t
(7-96)
Transfer rate
where ∆t = T1 – t Equating III and IV gives
(7-97)
638
Modeling of Chemical Kinetics and Reactor Design
Figure 7-27. Agitated batch vessel.
Mc
dt = UA∆t dθ
(7-98)
Rearranging Equation 7-98 gives dt UA = • dθ ∆t Mc
(7-99)
Integration of Equation 7-99 between the limits gives t2
∫
t1
θ
dt UA = dθ T1 − t Mc ∫0
(7-100)
Integration of Equation 7-100 from t1 to t2 while the batch processing time passes from 0 to θ yields: T − t UA ln 1 1 = •θ T1 − t 2 Mc
Fluid Mixing in Reactors
or θ =
where A c M T1 t1 t2 U θ
Mc T1 − t1 ln UA T1 − t 2 = = = = = = = =
639
(7-101)
heat transfer surface area specific heat of batch liquid weight of batch liquid heating medium temperature initial batch temperature final batch temperature overall heat transfer coefficient time
Example 7-10
A tank containing 50,000 lb (22,679.5 kg) material with a specific heat of 0.5 Btu/lb • °F (2.1 kJ/kg • K) is to be heated from 68°F (293 K) to 257°F (398 K). The tank contains a heating coil with a heat transfer surface of 100 ft2 (9.29 m2), and the overall heat transfer coefficient from the coil to the tank contents of 150 Btu/hr • ft2°F (850 W/m2 • K). Calculate the time required to heat the tank contents with steam condensing at 320°F (433 K).
Solution Select and apply the appropriate heat transfer formula. When heating a batch with an internal coil with an isothermal heating medium, the following equation applies: T − t UA ln 1 1 = •θ T1 − t 2 Mc
(7-101)
433 − 293 (850) (9.29) W m 2 kg • K ln θ • • = 433 − 398 (22, 679.5)(2.1) (10 3 ) m 2 K kg J
640
Modeling of Chemical Kinetics and Reactor Design
θ=
(1.386)(22, 679.5)(2.1)(10 3 ) hr (850)(9.29)(3, 600)
= 2.32 hr Computer software (BATCH) was developed to determine the time required for heating or cooling process fluids in a batch system. Table 7-18 gives the computer results of Example 7-10. BATCH REACTOR HEATING AND COOLING TEMPERATURE PREDICTION Start up of a jacketed batch reactor requires control of the heat-up and cool-down rates. This involves determining and setting the jacket heat transfer fluid temperatures. An alternative is to make a trial heat-up and incorporate the results into a time-dependent heat transfer equation: T − t Mc θ = ln 1 1 • T1 − t 2 U A
(7-101)
Equation 7-101 can also be used to calculate the heat-up time for non-isothermal heating (e.g., by hot-water jacketing), provided that the difference between the outlet and inlet jacket temperatures is not greater than 10% of the difference between the batch and average water temperature [47].
Table 7-18 Batch heating: internal coil isothermal heating
Fluid Mixing in Reactors
641
Assuming that M, c, U, and A are constants, where K=
UA Mc
(7-102)
Equation 7-101 becomes T −t 1 θ = ln 1 1 • T1 − t 2 K
(7-103)
Rearranging Equation 7-103 gives the jacket temperature as a function of time as: T1 =
t1 − t 2 e Kθ 1 − e Kθ
(7-104)
Thus, by taking a series of readings during a trial heat-up, K can be determined. The heat-up and cool-down times for varying jacket temperatures can then be predicted.
Example 7-11
Assume that in Example 7-10, the overall cycle time for a batch reaction is 8 hrs. The cycle time will include 2 hrs for heat-up and 3 hrs for cool-down. The batch will be heated from 20°C to the reaction temperature of 60°C, then cooled to 35°C. Using a hot-water jacket temperature of 80°C, it took 15 min to heat the batch from 20°C and 30°C. Calculate the jacket temperatures required for heat-up and cool-down. Solution From Equation 7-102,
K=
(850)(9.29) UA = Mc (22, 679.5)(2.1)(1, 000)
K = 0.00017 sec–1
1 kg • K J • m2 • • 2 kg J sec• m K
642
Modeling of Chemical Kinetics and Reactor Design
The jacket temperature required for a 2 hr heat-up can be obtained from Equation 7-104 as: T1 =
=
t1 − t 2 e Kθ 1 − e Kθ
(7-104)
0.00017 1 × 2 × 3, 600 sec sec
20 − 60 e
0.00071 1 × 2 × 3, 600 sec sec
1 − e
= 77°C The jacket temperature required for a 3 hr cool-down is: T1 =
=
t1 − t 2 e Kθ 1 − e Kθ 0.00017 1 × 3 × 3, 600 sec sec
60 − 35 e
0.00017 1 × 3 × 3, 600 sec sec
1 − e = 30.3°C
A Microsoft Excel spreadsheet (Example 7-11.xls) was developed for predicting the jacket temperature required for either heating up or cooling down reactants in a batch reactor. BATCH COOLING: INTERNAL COIL ISOTHERMAL COOLING MEDIUM Consider the same arrangement as before containing M of liquid with specific heat c and initial temperature T1 cooled by an isothermalvaporizing medium of temperature t1. If T is the batch temperature at any time θ, then dq ′ dT = − Mc = UA∆t dθ dθ
(7-105)
Fluid Mixing in Reactors
643
where ∆t = T – t1
(7-106)
Then − Mc
dT = UA∆t dθ
(7-107)
Substituting Equation 7-106 into Equation 7-107 and rearranging gives: T2
−∫
T1
θ
dT UA =∫ • dθ T − t1 0 Mc
(7-108)
Integration from T1 to T2 while the time passes from 0 to θ gives T − t UA ln 1 1 = •θ T2 − t1 Mc
or θ = where A c M T1 T2 t1 U θ
Mc T1 − t1 ln UA T2 − t1 = = = = = = = =
(7-109)
heat transfer surface area specific heat of batch liquid weight of batch liquid initial batch temperature final batch temperature cooling medium temperature overall heating transfer coefficient time BATCH HEATING: NON-ISOTHERMAL HEATING MEDIUM
The non-isothermal heating medium has a constant flowrate Wh, specific heat Ch, and inlet temperature T1, but a variable outlet temperature. For an unsteady state operation:
644
Modeling of Chemical Kinetics and Reactor Design
I
II
III
IV
dq ′ dt = Mc = Wh C h (T1 − T2 ) = UA∆t LMTD dθ dθ
(7-110)
The log mean temperature difference ∆tLMTD is: ∆t LMTD =
T1 − T2 T −t ln 1 T2 − t
(7-111)
Equating III and IV in Equation 7-111 and rearranging gives: Wh C h (T1 − T2 ) = UA
T1 − T2 T −t ln 1 T2 − t
(7-112)
Equation 7-112 becomes: T −t UA ln 1 = T2 − t Wh C h
(7-113)
UA
T1 − t = e Wh C h T2 − t
(7-114)
Rearranging Equation 7-114 gives T2 = t +
T1 − t e
UA Wh C h
(7-115)
UA
where K1 = e Wh C h
(7-116)
Equating II and III in Equation 7-110 and substituting Equation 7-115 into Equation 7-110 gives:
Fluid Mixing in Reactors
Mc
645
T − t dt = Wh C h T1 − t + 1 dθ K1 K − 1 = Wh C h 1 (T1 − t ) K1
(7-117)
Rearranging Equation 7-117 and integrating from t1 to t2 while the processing time passes from 0 to θ gives: t2
∫
t1
θ W C K − 1 dt = ∫ h h 1 dθ T1 − t 0 Mc K1
(7-118)
Integrating Equation 7-118 gives T −t W C K − 1 ln 1 1 = h h 1 θ Mc K1 T1 − t 2
K1 Mc T1 − t1 or θ = ln K1 − 1 Wh C h T1 − t 2 where A c Ch M T1 t1 t2 U Wh θ
= = = = = = = = = =
(7-119)
heat transfer surface area specific heat of batch liquid heating medium specific heat weight of batch liquid heating medium temperature initial batch temperature final batch temperature overall heat transfer coefficient heating medium flowrate time
BATCH COOLING: NON-ISOTHERMAL COOLING MEDIUM When cooling a batch with internal coil and a non-isothermal cooling medium, the following equation can be applied.
646
Modeling of Chemical Kinetics and Reactor Design
dq ′ dT = − Mc = Wc C c ( t 2 − t1 ) = UA∆t LMTD dθ dθ
where K 2 = e
(7-120)
UA Wc C c
T −t W C K − 1 and ln 1 1 = c c 2 θ T2 − t1 Mc K 2 K 2 Mc T1 − t1 or θ = ln K 2 − 1 Wc C c T2 − t1 where A c Cc M T1 T2 t1 U Wc θ
= = = = = = = = = =
(7-121)
heat transfer surface area specific heat of batch liquid coolant specific heat weight of batch liquid initial batch temperature final batch temperature initial coolant temperature overall heat transfer coefficient coolant flowrate time Example 7-12
For the tank described in Example 7-10, calculate the time required to cool the batch from 257°F (398 K) to 104°F (313 K) if cooling water is available at a temperature of 86°F (303 K) with a flowrate of 10,000 lb/hr (4535.9 kg/hr). Solution Select and apply the appropriate heat transfer formula. When cooling a batch with internal coil and a non-isothermal cooling medium, the following equation can be applied.
dq ′ dT = − Mc = Wc C c ( t 2 − t1 ) = UA∆t LMTD dθ dθ
(7-120)
Fluid Mixing in Reactors
647
where K 2 = e UA Wc C c T −t W C K − 1 and ln 1 1 = c c 2 θ T2 − t1 Mc K 2
(7-121)
K 2 = e UA Wc C c
=e
850 9.29 3, 600 )( ) )( ( 3 4 , 535 . 9 4 . 12 10 ( ) ( )
( )
2 J m kg • K • 3 • 2 kg hr 10 J • sec• m K hr 3, 600 sec
= 4.58 T −t W C K − 1 ln 1 1 = c c 2 θ T2 − t1 Mc K 2
398 − 303 ( 4, 535.9)( 4.12) 4.58 − 1 ln = 313 − 303 (22, 679.5)(2.1) 4.58 kg kJ 1 kg K × θ • • • θ hr kg.K kg kJ θ = 7.34 hr Table 7-19 gives the computer results from the software (BATCH) for batch cooling, non-isothermal cooling medium. BATCH HEATING: EXTERNAL HEAT EXCHANGER, ISOTHERMAL HEATING MEDIUM Figure 7-28 illustrates the arrangement in which the fluid in the tank is heated by an external heat exchanger. The heating medium is isothermal; therefore any type of exchanger with steam in the shell
648
Modeling of Chemical Kinetics and Reactor Design
Table 7-19 Batch cooling: non-isothermal cooling medium
Figure 7-28. Batch heating through an external heat exchanger, isothermal heating medium.
or tubes can be used (i.e., no advantage in the magnitude of ∆t can be observed by using a multi-pass design, such as a 2:4 type). The variable temperature from the exchanger t′ will defer from the variable tank temperature t. An energy balance around the tank and the heat exchanger gives:
Fluid Mixing in Reactors
I
dq ′ = dt
Mc
dt dθ
II
III
= Wh C h ( t ′ – t ) =
UA∆t LMTD
Heat entering the batch by recirculation
Transfer rate in the external exchanger
Heat accumulation in the batch
649
(7-122)
The log mean temperature difference ∆tLMTD is: ∆t LMTD =
=
(T1 − t ) − (T1 − t ′) T −t ln 1 T1 − t ′
t′ − t T −t ln 1 T1 − t ′
(7-123)
Equating II and III in Equation 7-122 gives: WhCh ( t ′ – t) = UA ∆tLMTD
(7-124)
That is: Wh C h ( t ′ − t ) = UA
(t ′ − t ) T −t ln 1 T1 − t ′
(7-125)
Rearranging Equation 7-125 gives T −t UA ln 1 = T t W − ′ 1 hCh
(7-126)
Equation 7-126 can be expressed as:
T1 − t = e
UA Wh C h
(T1 − t ′)
(7-127)
650
Modeling of Chemical Kinetics and Reactor Design UA
where K 3 = e Wh C h
T1 − t = K 3 (T1 − t ′ )
(7-128)
Therefore, T − t t ′ = T1 − 1 K3
(7-129)
Equating I and II in Equation 7-122 gives
Mc
dt = Wh C h ( t ′ − t ) dθ
(7-130)
Substituting Equation 7-129 into Equation 7-130 and rearranging yields T − t Mc dt • = T1 − 1 − t Wh C h dθ K 3 =
(K 3 − 1)(T1 − t ) K3
(7-131)
Rearranging Equation 7-131 and integrating from t1 to t2 while the time passes from 0 to θ gives: t2
∫
t1
K − 1 W C θ dt = 3 h h ∫ dθ T1 − t K 3 Mc 0
T − t K − 1 W C which yields ln 1 1 = 3 h h θ T1 − t 2 K 3 Mc
(7-132)
Fluid Mixing in Reactors
K 3 Mc T1 − t1 or θ = ln K 3 − 1 Wh C h T1 − t 2 where A c Ch M T1 t1 t2 U Wh θ
= = = = = = = = = =
651
(7-133)
heat transfer surface area specific heat of batch liquid heating medium specific heat weight of batch liquid heating medium temperature initial batch temperature final batch temperature overall heat transfer coefficient heating medium flowrate time
BATCH COOLING: EXTERNAL HEAT EXCHANGER, ISOTHERMAL COOLING MEDIUM When cooling a batch with an external heat exchanger and an isothermal cooling medium, the equation is: T −t W C K − 1 ln 1 1 = c c 4 θ Mc K 4 T2 − t1 K 4 Mc T1 − t1 or θ = ln K 4 − 1 Wc C c T2 − t1 where K4 A c Cc M T1 T2 t1 U Wc θ
= = = = = = = = = = =
eUA/WcCc heat transfer surface area specific heat of batch liquid coolant specific heat weight of batch liquid initial batch temperature final batch temperature initial coolant temperature overall heat transfer coefficient coolant flowrate time
(7-134)
652
Modeling of Chemical Kinetics and Reactor Design
BATCH COOLING: EXTERNAL HEAT EXCHANGER (COUNTER-CURRENT FLOW), NON-ISOTHERMAL COOLING MEDIUM When cooling a batch with an external heat exchanger and a nonisothermal cooling medium, the following equation can be used: T −t K − 1 Wb Wc C c ln 1 1 = 5 θ T2 − t1 M K 5 Wc C c − Wb c K W C − Wb c M T1 − t1 or θ = 5 c c ln Wb Wc C c K 5 − 1 T2 − t1 where K5 A c Cc M T1 T2 t1 U Wb Wc θ
= = = = = = = = = = = =
(7-135)
exp[UA(1/Wbc – 1/WcCc)] heat transfer surface area specific heat of batch liquid coolant specific heat weight of batch liquid initial batch temperature final batch temperature initial coolant temperature overall heat transfer coefficient batch flowrate coolant flowrate time Example 7-13
Calculate the time required to cool the batch described in Example 7-12 if an external heat exchanger with a heat transfer surface of 200 ft2 (18.58 m2) is available. The batch material is circulated through the exchanger at the rate of 25,000 lb/hr (11,339.8 kg/hr). The overall heat transfer coefficient in the heat exchanger is 200 Btu/hr • ft2 • °F (1,134 W/m2K). Solution Select and apply the appropriate heat transfer formula. When cooling a batch with an external heat exchanger and a non-isothermal cooling medium, the following equation can be used:
Fluid Mixing in Reactors
T −t K − 1 Wb Wc C c ln 1 1 = 5 θ M K 5 Wc C c − Wb c T2 − t1
653
(7-135)
where 1 1 − K 5 = exp UA Wc C c Wb c (1,134)(18.58)(3, 600) 1 1 − = exp 1, 000 (4, 535.9)(4.2) (11, 339.8)(2.1) J hr 3, 600 sec kg • K × • m2 • • • 3 10 J kg hr sec• K = 0.4509 T −t K − 1 Wb Wc C c ln 1 1 = 5 θ T2 − t1 M K 5 Wc C c − Wb c
398 − 303 0.4509 − 1 ln = 313 − 303 22, 679.5 (11, 339.8)(4, 535.9)(4.2) × θ (0.4509)( 4, 535.9)( 4.2) − (11, 339.8)(2.1) θ = 6.55 hr
Table 7-20 shows the computer results using an external heat exchanger involving a non-isothermal cooling medium. BATCH HEATING: EXTERNAL HEAT EXCHANGER AND NON-ISOTHERMAL HEATING MEDIUM When heating a batch reactor with an external heat exchanger and non-isothermal heating, the following equation applies:
654
Modeling of Chemical Kinetics and Reactor Design
Table 7-20 Batch heating/cooling of fluids external heat exchanger: (counter-current flow) non-isothermal cooling medium
T −t K − 1 Wb Wh C h ln 1 1 = 6 θ M K 6 Wh C h − Wb c T1 − t 2 M K 6 Wh C h − Wb c T1 − t1 or θ = ln K 6 − 1 Wb Wh C h T1 − t 2
where K6 A c Ch M T1 t1 t2 U Wb Wh θ
= = = = = = = = = = = =
(7-136)
exp[UA(1/Wbc – 1/WhCh)] heat transfer surface area specific heat of batch liquid heating medium specific heat weight of batch liquid heating medium temperature initial batch temperature final batch temperature overall heat transfer coefficient batch flowrate heating medium flowrate time
Tables 7-21 and 7-22 summarize the rules-of-thumb involving mixing, agitation, and reactors, respectively [48]. The following considerations are essential during mixing of fluids in a reactor [49]: 1. Whenever reaction rates are of the same magnitude as, or faster than, the mixing rate in a stirred reactor, mixing will have a
Fluid Mixing in Reactors
655
Table 7-21 Rules-of-thumb: mixing and agitation 1. Mild agitation is obtained by circulating the liquid with an impeller at superficial velocities of 0.1–0.2 ft/sec, and intense agitation at 0.7–1.0 ft/sec. 2. Intensities of agitation with impeller in baffled tanks are measured by power input, hp/1,000 gal, and impeller tip speeds: Operation Blending Homogeneous reaction Reaction with heat transfer Liquid-liquid mixtures Liquid-gas mixtures Slurries
hp/1,000 gal 0.2–0.5 0.5–1.5 1.5–5.0 5 5.0–10 10
Tip speed (ft/min) 7.5–10 10–15 15–20 15–20
3. Proportions of a stirred tank relative to the diameter D: liquid level = D; turbine impeller diameter = D/3; impeller level above bottom = D/3; impeller blade with = D/15; four vertical baffles with width = D/10. 4. Propellers are a maximum of 18 in.; turbine impellers to 9 ft. 5. Gas bubbles sparged at the bottom of the vessel will result in mild agitation at a superficial gas velocity of 1 ft/min and severe agitation at 4 ft/min. 6. Suspension of solids with a settling velocity of 0.03 ft/sec is accomplished with either turbine or propeller impellers, but when the settling velocity is above 0.15 ft/sec intense agitation with a propeller is needed. 7. Power to drive a mixture of a gas and a liquid can be 25%–50% less than the power to drive the liquid alone. 8. In–line blenders are adequate when a 1–2 sec contact time is sufficient, with power inputs of 0.1–0.2 hp/gal. Source: Walas, S. M., Chemical Process Equipment Selection and Design, Butterworths Series in Chemical Engineering, 1988.
serious impact on results. Poor mixing is a primary source of variability in products made in batch reactors. The results for a reaction run in a poorly mixed CFSTR may deviate strongly from those expected. 2. There is no single “correct” agitator type. Different agitator designs may perform equally well, or equally poorly, for a given application. Although some detailed design calculations can be performed, workable designs are often developed by trial and error.
656
Modeling of Chemical Kinetics and Reactor Design
Table 7-22 Rules-of-thumb: Reactors 11. The rate of reaction in every instance must be established in the laboratory, and the residence time or space velocity and product distribution eventually must be found in a pilot plant. 12. Dimensions of catalyst particles are 0.1 mm in fluidized beds, 1 mm in slurry beds, and 2–5 mm in fixed beds. 13. The optimum proportions for stirred tank reactors are when the liquid level is equal to the tank diameter, but at high pressures slimmer proportions are economical. 14. Power input to a homogeneous reaction stirred tank is 0.5–1.5 hp/1,000 gal, but three times this amount when heat is to be transferred. 15. Ideal continuous stirred tank reactor (CSTR) behavior is approached when the mean residence time is 5–10 times the length needed to achieve homogeneity, which is accomplished with 500–2,000 revolutions of a properly designed stirrer. 16. Batch reactions are conducted in stirred tanks for small daily production rates or when the reaction times are long, or when some condition such as feed rate or temperature must be programmed in some way. 17. Relatively slow reactions of liquids and slurries are conducted in continuous stirred tanks. A battery of four or five in series is most economical. 18. Tubular flow reactors are suited to high production rates at short residence times (sec or min) and when substantial heat transfer is needed. Embedded tubes or shell-and-tube construction are then used. 19. In granular catalyst packed reactors, the residence time distribution often is no better than that of a five-stage CSTR battery. 10. For conversions under about 95% of equilibrium, the performance of a fivestage CSTR battery approaches plug flow. Source: Walas, S. M., Chemical Process Equipment Selection and Design, Butterworths Series in Chemical Engineering, 1988.
3. Many reactions involve shear-sensitive materials, which severely limit the maximum mixing rate and make impeller and reactor design important. Mixing becomes the limiting factor.
DESIGN OF MIXING SYSTEMS The following procedure may be adopted in the design of a mixing vessel for a given process.
Fluid Mixing in Reactors
Table 7-23 Mixing equipment specifications
Reproduced with permission of PROCEDE.
657
658
Modeling of Chemical Kinetics and Reactor Design
Table 7-24 Reactor vessel specifications
Reproduced with permission of PROCEDE.
Fluid Mixing in Reactors
659
1. Study the properties of the liquid and physical requirements, and choose the type of impeller. 2. Select size ratios preferably the same as the standard values (Table 7-2) to avoid experimentation or based on small-scale studies. 3. Select impeller diameter DA for the larger system to accommodate the system being mixed. This leaves the impeller speed N as the only independent variable. 4. Choose N based on scale-up studies or commonly used rules. 5. Calculate the power P, mixing time θ, etc. Account for mechanical losses and the like when selecting a motor. 6. Change N and P to standard values. 7. Iterate and see if alternative designs requiring lower power exists. 8. Perform mechanical designs (e.g., to obtain shaft diameter, supports, bearing designs, etc.). Table 7-23 shows a mixing equipment specification sheet, which can be helpful as a general checklist. Generally, the specification sheet should not be completely relied on for a mixing problem, unless the problem is known or data are known that can be given to the manufacturer (e.g., blending, dispersing, or dissolving crystals). For unique problems, laboratory data should be carried out under the guidance of technical advice from the manufacturer or other qualified authority, in order that adequate scale-up data are taken and evaluated. It is essential that both a description and dimensions are given for the vessel to be used. Otherwise, request the manufacturer to recommend the type best suited to the service. Table 7-24 provides a reactor vessel specification data sheet.
REFERENCES 1. Danckwerts, P. V., Appl. Sci. Research, A3, 279, 1953. 2. Levenspiel, O., Chemical Reaction Engineering, 3rd ed., John Wiley & Sons, New York 1999. 3. Penny, W. R., “Guide to trouble free mixers,” Chem. Eng., 77 (12), 171, 1970. 4. Holland, F. A. and Chapman, F. S., Liquid Mixing and Processing in Stirred Tanks, Reinhold, New York, 1966. 5. Myers, K. J., Reeder, M., and Bakker, A., “Agitating for success,” The Chemical Engineer, pp. 39–42, 1996.
660
Modeling of Chemical Kinetics and Reactor Design
6. Uhl, V. W. and Gray, J. B., Eds. Mixing Theory and Practice, Volume 1, Academic Press Inc., New York, 1966. 7. Gates, L. E., Henley, T. L., and Fenic, J. G., “How to select the optimum turbine agitator,” Chem. Eng., p. 110, Dec. 8, 1975. 8. Hicks, R. W., Morton, J. R., and Fenic, J. G., “How to design agitators for desired process response,” Chem. Eng., p. 102, April 26, 1976. 9. Dickey, D. S., “Succeed at stirred tank reactor design,” Chem. Eng., pp. 22–31, Dec. 1991. 10. Rushton, J. H., Costich, E. W., and Everett, H. J., “Power characteristics of mixing impellers,” Chem. Eng. Prog, 46, 395, 1950. 11. Metzner, A. B. and Otto, R. E., “Agitation of non-Newtonian fluids,” AIChEJ, 3, pp. 3–10, 1957. 12. Dickey, S. D. and Fenic, J. G., “Dimensional analysis for fluid agitation systems,” Chem. Eng., Jan 5, 1976. 13. Fasano, J. B., Bakker, A., and Penny, W. R., “Advanced impeller geometry boosts liquid agitation,” Chem. Eng.,10(8), pp. 110–116, August 1994. 14. Gates, L. E., Hicks, R. W., and Dickey, D. S., “Application guidelines for turbine agitators,” Chem. Eng., 83, pp. 165–170, Dec. 6, 1976. 15. Cutter, L. A., AIChEJ, 12, 35, 1966. 16. Moo-Young, M., Tichar, K., and Dullien, F. A. L., AIChEJ, 18, 178, 1972. 17. van de Vusse, J. G., “Mixing by agitation of miscible liquids,” Chem. Eng. Sci., 4, 178, 1955. 18. Fox, E. A., and Gex, V. E., “Single phase blending of liquids,” AIChEJ, 2, 539, 1956. 19. Prochazka, J. and Landau, J., Coll Czech Chem Cummun, 26: 2961, 1961. 20. Moo-Young, M., Tichar, K., and Takahashi, F. A. L., “The blending efficiencies of some impellers in batch mixing,” AIChEJ, 18(1), pp. 178–182, 1972. 21. Sano, Y. and Usui, H., “Interrelations among mixing time, power number and discharge flow rate number in baffled mixing vessels,” J. Chem. Eng., Japan, 18:47–52, 1985. 22. Gray, J. B., “Batch mixing of viscous liquids,” Chem. Eng. Progr., 59, No. 3, p. 59, 1963. 23. Bakker, A. and Gates, L. E., “Properly choose mechanical Agitators for viscous liquids,” Chem. Eng. Prog., Dec. 1995.
Fluid Mixing in Reactors
661
24. Bates, R. L., Fondy, P. L., and Corpstein, R. R., I.E.C. Proc. Des., 2, 310, 1963. 25. Rautzen, R. R., Corpstein, R. R., and Dickey, D.S., “How to use scale-up methods for turbine agitators,” Chem. Eng., Oct. 25, 1976. 26. Norwood, K. W. and Metzner, A. B., “Flow patterns and mixing rates in agitated vessels,” AIChEJ, 6, 432, 1960. 27. Gupta, S. K.. “Momentum transfer operations,” Tata McGraw-Hill Publishing Co. Ltd., New Delhi, 1982. 28. Samant, K. D. and Ng, Ka, M., “Development of liquid-phase agitated reactors: synthesis, simulation and scale-up,” AIChEJ, Vol. 45, No. 11, pp. 2371–2391, November 1999. 29. Pahl, M. H. and Muschelknautz, “Static mixers and their applications,” Int, Chem. Eng., 22, pp. 195–205, 1982. 30. Coker, A. K., “Sizing process piping for single-phase fluids,” The Chemical Engineer, October 10, 1991. 31. Round, Can. J. Chem. Eng., 58, 122, 1980. 32. Lockhart, R.W. and Martinelli, R. C., Chem. Eng., Prog., 45, pp. 39–46, 1949. 33. Coker, A. K., “Understand two-phase flow in process piping,” Chem. Eng. Prog., pp. 60–65, November 1990. 34. Green, A., Johnson, B., and John, A., “Process intensification magnifies profits,” Chem. Eng., pp. 66–73, December 1999. 35. Chen, S. J., Kenics Technical data, KTEK-2, 1978. 36. Li, H. Z., Fasol, C., and Choplin, L., “Pressure drop of Newtonian and non-Newtonian fluids across a sulzer SMX static mixer,” Trans. IChemE, Vol. 75, Part A, pp. 792–798, Nov. 1997. 37. Bakker, A. and La Roche, R., “Flow and mixing with kenics static mixers,” Cray Channels, 15, 3, Cray Research Inc., Eagan, MN, pp. 25–28, 1993. 38. Bakker, A., et al., “Computerizing the steps in mixer selection,” Chem. Eng., 101, 3, pp. 120–129, March 1994. 39. Chopey, N. P., Handbook of Chemical Engineering Calculations, pp. 7–28, McGraw-Hill Book Company, 1984. 40. Zwietering, T. N., “Suspending of solid particles in liquid by agitators,” Chem. Eng. Sci., Vol. 8, pp. 244–253, 1958. 41. Weisman, J. and Efferding, L. E., AIChEJ, 6 (3), 419, 1960. 42. Nienow, A. W., Chem. Eng. Sci., 23, pp. 1453-1459, 1968. 43. Corpstein, R. R., Myers, K. J., and Fasano, J., “The high efficiency road to liquid-solid agitation,” Chem. Eng., Oct. 1994.
662
Modeling of Chemical Kinetics and Reactor Design
44. Bakker, A., Fasano, J., and Leung, D. E., “Pinpoint mixing problems with lasers and simulation software,” Chem. Eng., pp. 94–100, January 1994. 45. Bondy, F. and Lippa, S., “Heat transfer in agitated vessels,” Chem. Eng., pp. 62–71, 1983. 46. Dream, R. F., “Heat transfer in agitated vessels,” Chem. Eng., pp. 90–96, Jan. 1999. 47. McEwan, J., “How to predict batch reactor heating and cooling,” Chem. Eng., p. 179, May 1989. 48. Walas, M. S., Chemical Process Equipment Selection and Design, Butterworths Series in Chemical Engineering, 1988. 49. Falconer, J. L. and Huvard, G. S., “Important concepts in undergraduate kinetics and reactor design courses,” Chemical Engineering Education, pp. 140–141, Vol. 33, No. 2, Spring 1999.
Residence Time Distributions in Flow Reactors
663
CHAPTER EIGHT
Residence Time Distributions in Flow Reactors INTRODUCTION In the preceding chapters, the performance equations for ideal reactors were reviewed and the optimal temperature progressions of various industrial reactions were considered. Fluid mixing characteristics were also reviewed using various agitator types, and the power consumption, time for heating and cooling in batch systems, and the scale-up of mixers was determined. However, real reactors deviate from ideal ones and the differences are due to a number of factors. These factors include channeling of fluid as it moves through the reactor, the presence of stagnant regions within the reactor, bypassing or short-circuiting of portions of fluids in a packed bed, the longitudinal mixing caused by vortices and turbulence, and the failure of impellers or other mixing devices to provide perfect mixing. In an ideal continuous stirred tank reactor (CSTR), the reactant concentration is uniform throughout the vessel, while in a real stirred tank, the reactant concentration is relatively high at the point where the feed enters and low in the stagnant regions that develop in corners and behind baffles. In an ideal plug flow reactor, all reactant and product molecules at any given axial position move at the same rate in the direction of the bulk fluid flow. However, in a real plug flow reactor, fluid velocity profiles, turbulent mixing, and molecular diffusion cause molecules to move with changing speeds and in different directions. The deviations from ideal reactor conditions pose several problems in the design and analysis of reactors. In this chapter, we shall establish a basis for examining both qualitatively and quantitatively the effect of departure from idealized flow behavior on the performance of a reactor. 663
664
Modeling of Chemical Kinetics and Reactor Design
THE RESIDENCE TIME DISTRIBUTION FUNCTIONS AND THEIR RELATIONSHIPS Consider a homogeneous system as shown in Figure 8-1 through which matter is passing at a steady rate. The inlet and outlet streams are completely mixed, and there is a single exit from which the fluid elements cannot return to the system. If each fluid element is being timed as it enters the system and is stopped when it leaves, then each element at the exit has a time t associated with it, which determines the time spent in the system—this quantity is defined as the residence time for that element. In real systems there will be a spread of residence times leading to a residence time distribution (RTD). To predict the behavior of a system, it must be determined by how long different fluid elements remain in the system. Mac Mullin and Weber [1] introduced the concept of the RTD in the analysis of chemical reactors, and Danckwerts [2] developed this concept further in his classical paper, which has since formed the basis of various investigations involving flow systems in chemical and biochemical reactors. Levenspiel [3], Levenspiel and Bischoff [4], Himmelblau and Bischoff [5], Wen and Fan [6], and Shinnar [7] have given extensive treatments of this subject. AGE DISTRIBUTION FUNCTIONS AND RESIDENCE TIME DISTRIBUTION FUNCTION E(t) The “age” of an element of fluid is defined as the time elapsed since it entered the system. The fraction of fluid having ages between t and t + dt is (uc/m) • dt, where u is the volumetric rate of flow of fluid through the system, m is the quantity of tracer injected, and c is the local concentration of tracer at time t after injection. Danckwerts [8] introduced the concept of a fluid element or “point,” meaning a small volume with respect to the reactor vessel size, but still large enough
Figure 8-1. Steady-state homogeneous system.
Residence Time Distributions in Flow Reactors
665
to contain sufficient molecules to define continuous properties such as density and concentration. Consider a system of constant volume V through which a stream of fluid is passing at a steady volumetric rate u. If t is the age of elements in the stream at a point or over a region in the system, then the element whose age is between t and t + dt is known as the t-element. The relative frequency of the appearance of t-elements at a point or over a region in the system is an age distribution at the point or over that region. RESIDENCE TIME DISTRIBUTION FUNCTION E(t) This is defined as the fraction of material in the outlet stream that has been in the system for the period between t and t + dt, and is equal to E(t)dt, where E(t) is called the exit age distribution function of the fluid elements leaving the system. This is expressed as fraction of fluid leaving the vessel that has E( t )dt = residence time (exit age) of ( t, t + dt ) All fluid elements have some residence time, therefore, over a sufficiently long period, all tracer will eventually come out. This is represented by ∞
∫ E(t )dt = 1
(8-1)
0
The fraction of fluid element in the exit stream with age less than t1 is t1
∫ E(t )dt
(8-2)
0
Figure 8-2 shows the distribution of this property and the fraction of the elements for which the residence time is less than a given value t1. E(t) has the unit of inverse time (e.g., min–1), and in probability terms, E(t) is a density rather than a distribution. It is a fundamental indicator of the flow and mixing pattern in a chemical reactor and its
666
Modeling of Chemical Kinetics and Reactor Design
Figure 8-1. Residence time density function.
measurement is an important step in the analysis of non-ideal reactors. If a tracer is introduced into a reactor the concentration of the tracer is monitored at the exit stream, it is possible to ascertain the age distribution of the fluid elements within the reactor. The residence time distribution function must satisfy the following conditions: E(t) = 0 E(t) ≥ 0
for t < 0 since no fluid can exit before it enters. for t > 0 since mass fractions are always positive.
By definition, ∞
∫ E(t )dt = 1 0
CUMULATIVE RESIDENCE TIME DISTRIBUTION FUNCTION F(t) This function is the volume fraction of material in the outlet stream, which has been in the system for times less than t is equal to F(t). If
Residence Time Distributions in Flow Reactors
667
“ages” are assigned to the different fluid elements leaving the system, F(t) would be the volume fraction of the outlet stream having an age less than t. For constant density systems, volume fractions are the same as the weight fractions of the effluent with an age less than t. Therefore, the cumulative residence time distribution function F(t) is expressed by t
F( t ) = ∫ E( t ′ )dt ′
(8-3)
dF( t ) dt
(8-4)
0
or E( t ) =
It can also be expressed by t
∫ C(t ) u dt
F( t ) = ∞0
∫ C(t ) u dt
(8-5)
0
where C(t) = the effluent tracer concentration, (g tracer/l) u = the volumetric flowrate, (l/min) Replacing the integrals by finite differences yields t
F( t ) =
∑ (C(t )u δt ) 0 ∞
∑ (C(t )u δt )
(8-6)
0
If the data are at evenly spaced time increments and the mass flowrate is constant, this gives t
F( t ) =
∑ C(t ) 0 ∞
∑ C(t ) 0
(8-7)
668
Modeling of Chemical Kinetics and Reactor Design
It is possible to determine the cumulative residence time distribution function F(t) from either a tracer step-change or a tracer impulse response. From its definition, the properties of F(t) are: • • • •
F(t) = 0 when t < 0 F(t) ≥ 0 when t ≥ 0 F(∞) = 1 dF(t)/dt = E(t) > 0
The cumulative exit age distribution is a non-negative, monotone non-decreasing function as shown in Figure 8-3. INTERNAL AGE DISTRIBUTION FUNCTION I(t) The fraction of the material within the system for times between t and t + dt is equal to I(t)dt, where t is the age or length of time a fluid element has been in the vessel. I(t) has properties similar to E(t) for a perfect mixer. ∞
∫ I(t )dt = 1
(8-8)
0
t1
and
fraction of fluid element in vessel
∫ I(t )dt = younger than age t1 0
Figure 8-3. Cumulative residence time distribution function.
Residence Time Distributions in Flow Reactors
669
The exit age distribution function E(t) is obtained from outside the vessel while the internal age distribution function I(t) is obtained from inside the vessel. I(t) can be represented in terms of the RTD or the F-curve as I( t ) =
t u 1 − ∫ E( t )dt V 0
(8-9)
t
or t I( t ) = 1 − ∫ E( t )dt
(8-10)
0
where t = V/u = mean residence time In terms of F(t) I( t ) =
u [1 − F(t )] V
(8-11)
It also follows from Equation 8-9 that
E( t ) = − t
d I( t ) dt
(8-12)
For the perfectly mixed CSTR, the internal age distribution function is tI( t ) = 1 −
t
∫ 0
1 −t t e dt t
[ ]
= 1 + e−t
I( t ) =
t
t
0
1 −t t e = E( t ) t
(8-13)
Equation 8-13 shows that in a perfectly mixed vessel, the internal and exit conditions are identical. Figure 8-4 illustrates the internal age distribution characteristics.
670
Modeling of Chemical Kinetics and Reactor Design
Figure 8-4. Characteristic distribution of residence time, which is equivalent to age distribution of the inlet stream.
THE INTENSITY FUNCTION Λ(t) Naor and Shinnar [9] proposed the intensity function, which is defined as the fraction of fluid in the vessel of age t that will leave at a time between t and t+dt. The intensity function Λ(t) is related to the E(t) and I(t) functions from Amount of fluid Amount not leaving between = leaving before times ( t, t + dt ) time t
Fraction of age t that will leave between times ( t, t + dt )
Introducing the various definitions gives [uE(t)dt] = [V I(t)][Λ(t)dt] or Λ( t ) =
u E( t ) 1 E( t ) − dI( t ) 1 = = • V I( t ) t I( t ) dt I( t )
(8-14)
The intensity function Λ(θ) as shown in Figure 8-5 is useful in detecting the existence of dead space and bypassing, and it allows
Residence Time Distributions in Flow Reactors
671
Figure 8-5. Intensity function.
some insight into the basic mechanism of the flow processes. The pertinent features of Λ(θ) are: • The intensity function of a completely mixed vessel is a constant, Λ(θ) = 1, a straight line parallel to the abscissa. • The intensity function of two or more identical, ideally mixed vessels in series starts from the origin and increases monotonically to an asymptotic value (Λ → n), which is equal to the number of vessels. • There are no stagnant zones in the system. MEAN RESIDENCE TIME The average time spent by material flowing at volumetric rate u through a volume V is known as the mean residence time t , expressed as
t=
V u
The mean residence time t requires two conditions. First, there must not be a density change in the flowing stream as it passes through
672
Modeling of Chemical Kinetics and Reactor Design
the system; secondly, there must be no backmixing of the material in the system either upstream past the feed point, or of the product stream back into the system. It is also possible to determine t from the residence time distribution function E(t) by examining the contents of a vessel at time t = 0. This is expressed by
total volume of fluid in the vessel at t = 0
volume of fluid which had entered = ∑ all time t to t + dt seconds earlier
fraction of this fluid which stays more than t seconds in the vessel
This is expressed mathematically as
V=
∞
∞
t
∫ (u dt ) ∫ E(s) ds 0
(8-15)
where s is a dummy variable, the volumetric flowrate u is a constant, and E(s) is continuous. Therefore, ∞
V = u ∫0
∞ ∫ E(s) ds dt t
Applying integration by parts (i.e., ∫wdv = wv – ∫vdw) where w = ∫t∞E(s)ds v =t dv = dt
dw = − E( t ) dt
(applying Leibnitz’s rule)
dw = –E(t) dt yields
(8-16)
Residence Time Distributions in Flow Reactors
673
∞
∞ ∞ V = ∫ E(s) ds t − ∫ t[ – E( t )] dt u t 0 0 ∞
= 0 − 0 + ∫ t E( t ) dt 0
Therefore, t =
V = u
∞
∫ t E(t ) dt
(8-17)
0
NORMALIZED RTD FUNCTION E(θ) It is often convenient to use a dimensionless time θ and a corresponding version of the RTD E(θ). The dimensionless time θ is
θ=
t 1 and dθ = dt t t
The relationship between E(t) and E(θ) is found from the basis that both represent the same physical entity, the fraction of exit fluid with – age θ. Thus, E(θ)dθ = E(t)dt or (1/t )E(θ)dt = E(t)dt. Therefore,
E (θ ) = t E ( t )
(8-18)
For a perfectly mixed CSTR, it is assumed that the vessel contents are perfectly homogeneous and have the same composition as the exit stream. Considering a step input into the CSTR, a macroscopic material balance gives
dc dt
(8-19)
dc + c = co dt
(8-20)
uc o = uc + V
or t
Applying the Laplace transform to Equation 8-20, which is of the form L(dy/dx) = sy (s) – yo, with the initial condition yo = 0, gives
674
Modeling of Chemical Kinetics and Reactor Design
t{sc(s) − c o } + c(s) =
or c(s) {ts + 1} =
co s
co s
(8-21)
Rearranging Equation 8-21 gives
c(s) 1 = co s(st + 1)
(8-22)
Converting Equation 8-22 into partial fraction and solving yields c(s) 1 t = − c o s st + 1
(8-23)
The inverse Laplace transform of Equation 8-23 gives c( t ) = 1 − e−t co = F(θ)
t
(8-24)
(by definition)
Consequently, since E( t ) =
dF(θ) dt
1 E( t ) = e − t t
t
(8-25)
Substituting Equation 8-25 into Equation 8-18 gives E(θ) = e–θ
(8-26)
The internal age distribution function in terms of F(θ) gives
Residence Time Distributions in Flow Reactors
I( t ) =
675
1 [1 − F(θ)] t
1 = e−t t
t
(8-27)
I(θ) = e–θ = E(θ)
(8-28)
The intensity function Λ(t) in terms of E(t) and I(t) gives Λ( t ) =
1 E( t ) 1 = t I( t ) t
(8-29)
or Λ(θ) = 1
(8-30)
During plug flow, all material passes through the vessel without any mixing, and each fluid element stays in the vessel for exactly the same length of time. For a step input, the front or interface between the tracer and non-tracer fluids traverses down the vessel and exits at the other end in a time equal to the mean residence time t . Therefore, the F(θ) curve is a step function and is expressed as F (θ ) = U ( t − t )
where U( t − t ) ={1
0
I( t ) =
(8-31) tt
[
]
1 [1 − F(θ)] = 1t 1 − U(t − t ) t
or E( t ) =
dF d = U( t − t ) = δ ( t − t ) dt dt
(8-32)
(8-33)
I(θ) = 1 – U(θ – 1)
(8-34)
E(θ) = δ(θ – 1)
(8-35)
The intensity function for plug flow is
676
Modeling of Chemical Kinetics and Reactor Design
Λ( t ) =
δ( t − t ) 1 − U( t − t )
(8-36)
which by a limiting process is shown to be equivalent to 0≤t
Λ( t ) ={+∞ 0
(8-37)
t=t
or Λ(θ) ={+∞ 0
0 ≤ θ <1
(8-38)
θ =1
Table 8-1 gives the relationships between the age distribution functions and Figure 8-6 shows the age distribution functions of ideal reactors. In using the normalized distribution function, it is possible to directly compare the flow performance inside different reactors. If the normalized function E(θ) is used, all perfectly mixed CSTRs have numerically the same RTD. If E(t) is used, its numerical values can change for different CSTRs. MOMENTS OF RESIDENCE TIME DISTRIBUTIONS A recommended method of characterizing the RTD in flow systems is by using their moments. These are known as the mean, variance, and skewness. The mean value or the centroid of distribution for a concentration versus time curve is ∞
µ = t=
∫ tC(t )dt 0 ∞
(8-39)
∫ C(t )dt 0
If the distribution curve is only known at a number of discrete time values, ti, then the mean is expressed by
µ = t =
t =∞
t =∞
t=0 t =∞
t=0 t =∞
∑ t iC(t i ) ∆t i ∑ C(t i )∆t i
t=0
=
∑ t C(t ) ∑ C(t )
t=0
(if ∆ti is constant)
(8-40)
Residence Time Distributions in Flow Reactors
677
Table 8-1 Relationships between the age distribution functions Functions C(θ) =
Definitions
dF(θ) dθ
E(θ) = tE( t ) =
θ
F(θ) = ∫ C(θ ′ )dθ ′
dI( t ) − dI(θ) = −t 2 dθ dt θ
t
0
0
1 − I(θ) = 1 − tI( t ) = ∫ E(θ ′ )dθ ′ = ∫ E( t ′ )dt ′
0
F (θ ) + I (θ ) = 1 θ
F(θ) = 1 − I(θ) = ∫ Edθ = 1 − ∑ E∆θ 0
E(θ) − d ln I(θ) E( t ) 1 dI( t ) Λ ( θ ) = tΛ ( t ) = • = = =− I (θ ) dθ tI( t ) I( t ) dt θ
1 − ∫ E(θ)dθ = 1 − F(θ) = I(θ) = W(θ)
I(θ)
0
E(θ)
E(θ) = dF(θ) dθ = − dW(θ) dθ = − dI(θ) dθ
W(θ)
1 − ∫ E(θ)dθ = 1 − F(θ) = I(θ)
θ 0
1
∫ F(θ)dθ
H
0
In terms of dimensionless time θ = t / t . To convert to E(t), F(t) etc., use dt = t dθ; E(θ) = t E(t); F(θ) = F(t); I(θ) = t I(t); W(θ) = W(t). E, F, and W are RTD functions. I and H are not RTD functions.
∞
or µ = t =
∫ tE(t ) dt 0 ∞
∫ E(t )dt
=
∑ t i E(t i )∆t i ∑ E(t i )∆t i
(8-41)
0
The second moment is taken about the mean and is referred to as the variance or square of the standard deviation σ2, defined by
678
Modeling of Chemical Kinetics and Reactor Design
Figure 8-6. Age distribution functions of ideal reactors. (Source: Wen and Fan [6]).
Residence Time Distributions in Flow Reactors ∞
σ2 =
∫ (t − t ) C(t ) dt 0
∞
∫ t 2C(t )dt
2
∞
679
=
0 ∞
∫ C(t ) dt
− t2
(8-42)
∫ C(t )dt
0
0
In discrete form σ2 is
∑ (t i − t ) C(t i ) ∆t i ∑ C(t i )∆t i 2
σ = 2
=
∑ t 2i C(t i ) ∆t i ∑ C(t i )∆t i
or σ 2 =
∞
− t2
∞
∫ (t − t ) E(t )dt = ∫ t 2 E(t )dt − t 2 2
0
=
(8-43)
0
∑ t 2i E(t i )∆t i ∑ E(t i )∆t i
− t2 =
∑ t 2i E(t i )∆t i − t 2
(8-44)
The dimensionless variance σ2θ is expressed as
σ θ2 =
σ2 = t2
∞
∫ (θ − 1) E(θ)dθ 2
(8-45)
0
The magnitude of the variance σ represents the square of the distribution spread and has the units of (time)2. The greater the value of this moment, the greater the spread of the RTD. The variance is particularly useful for matching experimental curves to one of a family of theoretical curves. The third moment is taken about the mean and is known as the skewness, γ. It is defined by ∞
γ = ∫ ( t − t ) E( t )dt 0
3
(8-46)
680
Modeling of Chemical Kinetics and Reactor Design
The magnitude of this moment measures the extent that the distribution is skewed in one direction or another in reference to the mean.
DETERMINING RTD FROM EXPERIMENTAL TRACER CURVES Previously, the RTD functions for flow systems were described. In practice, the RTD is determined experimentally by injecting a tracer at the inlet of the system and monitoring the response at the outlet; information about the system is derived from these results. In a tubular reactor, the RTD measurements are used to determine how closely the plug flow assumption is obeyed. Wen and Fan [6] have provided a comprehensive listing of various tracers and experimental techniques for determining the RTD in flow systems. Recent studies [10,11,12] have been performed employing an impulse tracer to determine the RTD in bubble columns and an oscillatory flow electrochemical reactor. The author [13,14] has employed both step-change and an impulse to determine the RTD of nozzle type reactors: analysis of the RTD involves an atomic absorption spectrophotometer (AAS), a cine-projector, and a chart recorder. Figures 8-7 and 8-8 show the nozzle-type reactors and the AAS, respectively. Figure 8-9 gives a typical response curve from the AAS. The methods used in determining the RTD are an impulse signal and a step-change or a periodic input of the tracer. The following reviews these methods of injecting a tracer to analyze the RTD in flow systems. IMPULSE SIGNAL Suppose that a quantity m of tracer is injected at the inlet of a system during a period of time, which is very short compared to the mean residence time, t . The concentration of this tracer material is measured in the outlet stream as a function of time. Assume the following conditions: 1. Constant flowrate u(l/min) and fluid density ρ(g/l). 2. Only one flowing phase. 3. Closed system input and output by bulk flow only (i.e., no diffusion takes place across the system boundaries). 4. Flat velocity profiles at the inlet and outlet.
Residence Time Distributions in Flow Reactors
681
Figure 8-7. Cylindrical nozzle reactors.
Figure 8-8. Atomic absorption spectrophotometer with 16 mm cine projector in place.
682
Modeling of Chemical Kinetics and Reactor Design
Figure 8-9. A typical RTD response curve from an AA spectrophotometer.
5. Linearity with respect to the tracer analysis, that is, the magnitude of the response at the outlet is directly proportional to the amount of tracer injected. 6. The tracer is completely conserved within the system and is identical to the process fluid in its flow and mixing behavior. Any tracer can be chosen for the given system, providing it satisfies the following conditions: • It should not affect the flow. • It should be injected in a short time and be conveniently analyzed by a suitable method. • It should not react with or be absorbed by the surface of the system. • Its molecular diffusivity should be low and it should be conserved (i.e., a mass balance on it must be possible).
Residence Time Distributions in Flow Reactors
683
• The tracer must be uniformly distributed in the inlet fluid, and the analysis of the exit should give a proper average concentration in the outlet fluid. In a time period from t = 0 to t = δt seconds, a quantity mi(g) of a tracer is introduced at the system inlet, and the tracer concentration C(t) (g/l) is measured in the exit from the system. Subject to the above conditions, the residence time density function from the measured tracer response is: Tracer concentration in the outlet (or a quantity proportional to it ) C( t ) at time t (8-47) E( t ) = ∞ = Total area under tracer concentration ∫ C(t )dt (or a quantity proportional to it ) curve 0 versus time as measured at the outlet Consider the tracer leaving a system between t and t + δt. From the definition of E(t), the quantity of tracer is miE(ti)δt
(8-48)
From the definition of C(t), the concentration of tracer in the outlet is C(t) • u • δt
(8-49)
Therefore, miE(t)δt = C(t)uδt
(8-50)
u C( t ) mi
(8-51)
or E( t ) =
Using Equation 8-51 it is possible to determine E(t) from the measured response C(t), if both the volumetric flowrate u and the mass of tracer injected mi are known. Since the mass of tracer emerging in the interval from t and t + δt is C(t)uδt, then the total quantity of the tracer is:
684
Modeling of Chemical Kinetics and Reactor Design ∞
m i = ∫ u C( t ) dt
(8-52)
0
∞
or
mi = C( t )dt u ∫0
(8-53)
Substituting Equation 8-53 into Equation 8-51 gives E( t ) =
∞
C( t )
(8-54)
∫ C(t )dt 0
If the concentration of tracer in the outlet stream is not measured directly, a quantity R I(t), which is proportional to C(t), must be measured. For example, RI(t) may be light absorbance if the tracer is a dye, a conductance if the tracer is an electrolyte, or a counting rate if a radioactive tracer is used. If C(t) = kRI(t), where k is the proportionality constant, it can be substituted in Equation 8-54 to give the residence time density function E(t) as E( t ) =
∞
R I (t )
(8-54)
∫ R I (t )dt 0
Figure 8-10 shows typical pulse input and output signals.
STEP-CHANGE If the feed to a system is switched instantaneously from one supply to another, a step-change residence time experiment can be performed. The second feed must be distinguishable from the first, but both should have the same density and viscosity and behave in the same manner within the system. A step signal is often performed by switching from undyed to dyed feed, unless the tracer is expensive or unpleasant (e.g., radioactive tracers); in such a case, an impulse tracer is used.
Residence Time Distributions in Flow Reactors
685
Figure 8-10. Arbitrary pulse input and output signals.
Consider the effluent from a system at time t after the step-change to a marked feed has taken place. The concentration of the tracer in the effluent is related to the F-function of the system because all unmarked material in the effluent must be in the system for a time greater than t. If P is some property that varies linearly with the volume fraction of feed one in a mixture of feed two, then
686
Modeling of Chemical Kinetics and Reactor Design
1 − F( t ) =
or F( t ) =
P2 − P( t ) P2 − P1
P( t ) − P1 P2 − P1
(8-56)
A graph of P(t) versus time would show a change from P1 (before the step-change) to P2 (a long time afterwards), and this gives the F-curve of the system. Figure 8-11 shows a typical F-curve. The F-curve can also be determined from the E-curve obtained by a pulse experiment according to Equation 8-3. For a plug flow reactor, the step is extremely sharp, and in the limit it would approach a Heaviside function at the mean residence time. The Heaviside unit function H(t – to) is H(t – to) = 0
for t < to
= 1
for t > to
It enables the step-change to be formulated mathematically
Figure 8-11. Step change analysis.
Residence Time Distributions in Flow Reactors
δ( t − t o ) =
dH( t − t o ) dt
687
(8-57) PERIODIC INPUT
A periodic variation (e.g., a sinusoidal variation) of the concentration of the tracer in some property of the feed into a system can also be used. Measurement of the attenuation and phase shift of such an input signal is then related to the RTD. The advantage of this method is that it averages out the slight variations in both the feed rate and mixing as the effect of noise is minimized. This method of input is rather complex and, therefore, is only used in laboratory investigation. Figure 8-12 shows a graphical representation of the sinusoidal response of a linear system. From the input signal (i.e., as a function of various sinusoidal frequencies of the input signal), the periodic response analysis makes it possible to determine the amplitude change and the phase shift of the response of the system. This is then compared with the response of the mathematical model under consideration.
Figure 8-12. Sinusoidal response.
688
Modeling of Chemical Kinetics and Reactor Design
INTERPRETATION OF TRACER EXPERIMENTS Previously, the forms of the age distribution curves for the various ideal flow reactors were reviewed. However, the actual experimental curves produced by the tracer techniques will often deviate from these curves depending on the extent and type of mixing encountered in real systems. The degree of mixing is related to the spread and peak of the E-curves. The narrower the degree of mixing, the narrower and sharper the E-curve. The tracer information may need to be assessed as to whether the reactor shows considerable bypassing of the fluid, a large dead space, or gross channeling of the fluid. For example, a tracer impulse injected at the inlet of a reactor may produce two peaks, the first corresponding to the channeling of the fluid and the second to the bulk fluid. Bypassing, short-circuiting, or channeling occurs when a certain amount of fluid immediately leaves the system and fails to mix with the bulk of the fluid. An imperfect packing in a fixed bed reactor is a possible cause of this phenomenon, and an overly close arrangement of the inlet and outlet of a CSTR is another. Stagnant zones, dead corners, or dead space imply that a certain part of the liquid does not mix or exchange with inlet or outlet streams, thereby reducing the reactor effective volume. Improving the flow is possible by inserting redistributors and through proper baffling, respectively. Piston flow signifies that some of the liquid passes through the reactor in plug flow. This liquid, unlike that involved in short-circuiting, has a certain residence time in the reactor. In certain operations, it is essential that the flow approach as close as possible some ideal situation, usually plug flow (e.g., in continuous, large-scale chromatographic separations). These non-idealities enable us to construct useful flow models from the tracer information. Figures 8-13, 8-14, and 8-15, respectively, show the E-curve, F-curve, I-curve, and Λ-curve for reactors with bypassing, dead space (stagnancy), and channeling.
ANALYSIS OF RTD FROM PULSE INPUT The discrete data can be analyzed from the residence time distribution by using either the histogram method or the trapezoidal rule (text continued on page 692)
Residence Time Distributions in Flow Reactors
689
Figure 8-13. E-curve, F-curve, I-curve, and Λ-curve for a typical system with bypassing.
690
Modeling of Chemical Kinetics and Reactor Design
Figure 8-13. continued
Residence Time Distributions in Flow Reactors
691
Figure 8-14. E-curve, F-curve, and Λ-curve for a typical system with dead space.
692
Modeling of Chemical Kinetics and Reactor Design
Figure 8-14. continued
(text continued from page 688)
method to determine the required areas. In the histogram method, the area under the response curve is the sum of the rectangular areas whose heights are the individual measured responses. This is expressed by: area =
n
∑ C i (t ) ∆t i
(8-58)
i =1
where ∆ti is a time interval (or the width of the ith rectangle), and is defined by: ∆t i =
∆t i =
t1 + t 2 2
( i = 1)
(8-59)
( t i + 1 − t i ) + ( t i − t i −1 ) = t i + 1 − t i −1 2
2
( i = 2 to n − 1)
(8-60)
Residence Time Distributions in Flow Reactors
693
Figure 8-15. E-curve and F-curve for a typical system with channeling.
694
Modeling of Chemical Kinetics and Reactor Design
In the trapezoidal rule method, the area under the response curve is: n −1
area = ∑ C i ( t )average ∆t i i =1
n −1
= ∑ i =1
C i + C i +1 (t − t ) i +1 i 2
(8-61)
The mean residence time t and the variance σ2t are given by n −1
[
]
t = ∑ t i E i ( t )average ∆t i i =1
n −1 σ 2t = ∑ t 2i E i ( t ) i =1
[
(8-62)
]average ∆t i − t 2
(8-63)
Missen et al. [15] have developed numerical methods for the step input F(t). Figure 8-16 illustrates a typical method of determining the area under C(t) versus t curve. Example 8-1
A pulse of tracer is fed to the reactor and the following exit concentrations are reported. Determine the mean residence time, variance, E(θ), F(θ), and I(θ) distribution curves from the effluent tracer concentration as shown in Table 8-2. Solution The mean residence time t is obtained from Equation 8-39, which is the first moment. ∞
µ= t=
∫ t C(t )dt 0 ∞
∫ C(t )dt 0
(8-39)
Residence Time Distributions in Flow Reactors
695
Figure 8-16. Trapezoidal method of area determination.
In discrete form, ∞
µ =t =
∑ t C(t )δt 0 ∞
∑ C(t )δt 0
The variance is the second moment, and is defined by
(8-40)
696
Modeling of Chemical Kinetics and Reactor Design
Table 8-2 Effluent tracer concentration Time (min)
Effluent tracer concentration, g/cm3
0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0
0.0 1.5 3.0 4.5 5.0 5.2 5.0 4.5 4.0 4.0 2.0 1.0 0.5 0.2 0.0
∞
σ2 =
∫ t 2C(t )dt 0 ∞
− t2
(8-42)
∫ C(t )dt 0
or in discrete form is expressed as ∞
σ2 =
∑ t 2C(t )δt 0 ∞
∑ C(t )δt
− t2
(8-43)
0
Table 8-3 gives the parameters for calculating the mean residence time, variance, E(θ), F(θ), and I(θ) values. The mean residence time t with δt = 2.5 is
Residence Time Distributions in Flow Reactors
697
Table 8-3 2
t
C(t)
tC(t)
t C(t)
0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0
0.0 1.5 3.0 4.5 5.0 5.2 5.0 4.5 4.0 4.0 2.0 1.0 0.5 0.2 0.0
0.00 3.75 15.00 33.75 50.0 65.0 75.0 78.75 80.00 90.00 50.00 27.50 15.00 6.50 0.00
0.000 9.375 75.000 253.125 500.000 812.500 1,125.000 1,378.125 1,600.000 2,025.000 1,250.000 756.25 450.00 211.25 0.00
Total
40.4
590.25
10,445.625
E(t) min–1
θ
E(θ)
0.000 0.015 0.030 0.045 0.050 0.051 0.050 0.045 0.040 0.040 0.020 0.010 0.005 0.002 0.000
0.000 0.171 0.342 0.513 0.684 0.856 1.027 1.198 1.369 1.540 1.711 1.882 2.053 2.225 2.396
0.000 0.219 0.438 0.657 0.731 0.745 0.731 0.657 0.584 0.584 0.292 0.146 0.073 0.029 0.000
∞
∑ t C(t )δt (590.25)(2.5) µ = t = 0∞ = (40.4)(2.5) ∑ C(t )δt 0
= 14.61 min ∞
The variance σ 2 =
∑ t 2C(t )δt 0 ∞
∑ C(t )δt
− t2
0
=
(10, 445.625)(2.5) − 14.612 (40.4)(2.5)
σ2 = 45.10 min2
698
Modeling of Chemical Kinetics and Reactor Design
The exit age residence time distribution function E(t) is
E( t ) =
∞
C( t )
∑ C(t )δt
(8-54)
0
∞
where Σ C(t)δt = (40.4)(2.5) = 101. 0
The dimensionless residence time θ = t / t and E(θ) = tE (t). Table 8-4 shows the details of the summation, which is performed using the trapezoidal rule. The internal age distribution I(θ) is obtained from I(θ) = 1 − F(θ) = 1 − ∑ Eδθ
The Microsoft Excel spreadsheet (Example8-1.xls) was developed to calculate the moments (mean residence time and variance) and the
Table 8-4 Area present in the interval between i – 1 and i, θ
E(θ)
0.000 0.171 0.342 0.513 0.684 0.856 1.027 1.198 1.369 1.540 1.711 1.882 2.053 2.225 2.396
0.000 0.219 0.438 0.657 0.731 0.745 0.731 0.657 0.584 0.584 0.292 0.146 0.073 0.029 0.000
E i (θ ) =
(Ei + Ei − 1)(θi − θi − 1) 2 0.000 0.019 0.056 0.094 0.119 0.126 0.126 0.119 0.106 0.100 0.075 0.037 0.019 0.009 0.002
Summing to θi = –∑Eδθ
I = 1 –∑Eδθ
F(θ)
I(θ)
0.000 0.019 0.075 0.169 0.288 0.414 0.540 0.659 0.765 0.865 0.940 0.977 0.996 1.005 1.007
1.000 0.981 0.925 0.831 0.712 0.586 0.460 0.341 0.235 0.135 0.060 0.023 0.004 — —
Residence Time Distributions in Flow Reactors
699
RTD functions, E(θ), F(θ), and I(θ). Figure 8-17 shows plots of E(θ), F(θ), and I(θ) versus θ. Example 8-2
Levenspiel and Smith (1957)* have reported the following data obtained from a residence time experiment involving a length of 2.85cm diameter pyrex tubing. A volume of potassium permanganate (KMnO4) solution that would fill a 2.54 cm length of the tube was rapidly injected into a water stream with a linear velocity of 35.70 cm/sec. A photoelectric cell 2.74 m downstream from the injection point was used to monitor the local KMnO4 concentration. Determine the mean residence time of the fluid, the variance, E(θ), F(θ), and I(θ) from the following effluent KMnO4 concentrations. *
Chem. Eng. Sci. 6, 227 (1957).
Figure 8-17. Residence time distribution functions E(θ), F(θ), and I(θ) versus θ.
700
Modeling of Chemical Kinetics and Reactor Design
Time (sec)
KMnO4 concentration (arbitrary units)
0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.0 34.0 36.0 38.0 40.0 42.0
0.0 11.0 53.0 64.0 58.0 48.0 39.0 29.0 22.0 16.0 11.0 9.0 7.0 5.0 4.0 2.0 2.0 2.0 1.0 1.0 1.0 1.0
Solution A table was constructed to determine the mean residence time t , variance σ2, E(θ), F(θ), and I(θ) parameters from the effluent tracer versus time data. The mean residence time t with δt = 2.0 is ∞
∑ t C(t )δt (4, 252)(2.0) µ = t = 0∞ = = 11.016 (386)(2.0) ∑ C(t )δt
sec
(8-40)
0
∞
The variance σ 2 =
∑ t 2C(t )δt 0 ∞
∑ C(t )δt
− t2
0
=
(65, 392.0)(2.0) − 11.016 2 = 48.06 sec2 (386)(2.0)
(8-43)
Residence Time Distributions in Flow Reactors
701
The exit age residence time distribution function E(t) is
E( t ) =
∞
C( t )
∑ C(t )δt
(8-54)
0
∞
where Σ C(t)δt = (386)(2.0) = 772. 0
The dimensionless residence time θ = t / t and E(θ) = tE (t). Table 8-5 shows the details of the summation, which is performed using the trapezoidal rule. The internal age distribution I(θ) (Table 8-6) is obtained from I(θ) = 1 – F(θ) = 1 – ∑Eδθ. An Excel spreadsheet (Example8-2.xls) was developed and Figure 8-18 shows plots of E(θ), F(θ), and I(θ) versus θ.
Table 8-5 Time, sec
C(t)
0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0 30.0 32.0 34.0 36.0 38.0 40.0 42.0
0.0 11.0 53.0 64.0 58.0 48.0 39.0 29.0 22.0 16.0 11.0 9.0 7.0 5.0 4.0 2.0 2.0 2.0 1.0 1.0 1.0 1.0
Total
386.0
t2C(t)
E(t) sec–1
θ
E(θ)
0.0 22.0 212.0 384.0 464.0 480.0 468.0 406.0 352.0 288.0 220.0 198.0 168.0 130.0 112.0 60.0 64.0 68.0 36.0 38.0 40.0 42.0
0.0 44.0 848.0 2,304.0 3,712.0 4,800.0 5,616.0 5,684.0 5,632.0 5,184.0 4,400.0 4,356.0 4,032.0 3,380.0 3,136.0 1,800.0 2,048.0 2,312.0 1,296.0 1,444.0 1,600.0 1,764.0
0.000 0.014 0.069 0.083 0.075 0.062 0.051 0.038 0.028 0.021 0.014 0.012 0.009 0.006 0.005 0.003 0.003 0.003 0.0013 0.0013 0.0013 0.0013
0.000 0.182 0.363 0.545 0.726 0.908 1.089 1.271 1.452 1.634 1.816 1.997 2.179 2.360 2.542 2.723 2.905 3.086 3.268 3.450 3.631 3.813
0.000 0.154 0.760 0.914 0.826 0.683 0.562 0.419 0.308 0.231 0.154 0.132 0.099 0.066 0.055 0.033 0.033 0.033 0.014 0.014 0.014 0.014
4,252.0
65,392.0
tC(t)
702
Modeling of Chemical Kinetics and Reactor Design
Table 8-6 Area present in the interval between i – 1 and i, θ
E(θ)
0.000 0.000 0.182 0.154 0.363 0.760 0.545 0.914 0.726 0.826 0.908 0.683 1.089 0.562 1.271 0.419 1.452 0.308 1.634 0.231 1.816 0.154 1.997 0.132 2.179 0.099 2.360 0.066 2.542 0.055 2.723 0.033 2.905 0.033 3.086 0.033 3.268 0.014 3.450 0.014 3.631 0.014 3.813 0.014
E i (θ ) =
Summing to θi = –∑Eδθ
I = 1 –∑Eδθ
F(θ)
I(θ)
0.000 0.014 0.097 0.249 0.407 0.544 0.657 0.746 0.812 0.861 0.896 0.922 0.943 0.958 0.969 0.977 0.983 0.989 0.993 0.996 0.999 1.002
1.000 0.986 0.903 0.751 0.593 0.456 0.343 0.254 0.188 0.139 0.104 0.0.78 0.057 0.042 0.031 0.023 0.017 0.011 0.007 0.004 0.001 —
(Ei + Ei − 1)(θi − θi − 1) 2 0.000 0.014 0.083 0.152 0.158 0.137 0.113 0.089 0.066 0.049 0.035 0.026 0.021 0.015 0.011 0.008 0.006 0.006 0.004 0.003 0.003 0.003
Example 8-3
Hull and von Rosenberg (1960)* injected a pulse of radioactive tracer into the catalyst inlet at the bottom of a reactor. The radioactive tracer concentration was then measured at various points in the reactor. The catalyst rate was 340 lb/hr and the holdup was 18.4 lb. The results of the tracer response were given as follows: Time, t min 0 0.5 1.0 1.5 *
Ind. Eng. Chem. 52, 989 (1960).
Counts/min × 10–3 (smoothed to equidistant points) 0 5 22 27
Residence Time Distributions in Flow Reactors 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
703
26 22 19 15 10 7 4 3 3 (1) (0) 164
Figure 8-18. Residence time distribution functions E(θ), F(θ), and I(θ) versus θ.
704
Modeling of Chemical Kinetics and Reactor Design
Determine the various distribution functions, namely E(θ), F(θ), and I(θ). Solution A Microsoft Excel spreadsheet (Example8-3.xls) was developed to determine the E(θ), F(θ), and I(θ) distribution functions. The results of the spreadsheet calculations give the mean residence time from the distribution curve n −1
[
]
t = ∑ t i E i ( t )average δt i =1
(8-62)
= 2.53 min The variance σt2 is: n −1 σ 2t = ∑ t 2i E i ( t ) i =1
[
]average δt i − t 2
(8-63)
= 1.7 min2 The experimental mean residence time t exp t is: t ept =
(18.4)(60) 340
= 3.25 min There is approximately a 22% deviation between the experimental and the distribution mean residence time. However, the main purpose was to use the information from the RTD curve to improve the reactor operation. The results of the RTD provided vital information concerning the effects of operating conditions and structural designs on solidmixing patterns in fluidized systems. The perfect mixing function was generated by e–θ, where θ = t / t . Figure 8-19 shows plots of these functions against dimensionless residence time θ.
Residence Time Distributions in Flow Reactors
705
Figure 8-19. Residence time distribution functions E(θ), F(θ), and I(θ) versus θ.
Example 8-4
The response to an impulse input has the shape of a trapezoid with equations
C=
t−2 3
when 2 ≤ t ≤ 5 when 5 ≤ t ≤ 8
11 − t 0
when 8 ≤ t ≤ 11 elsewhere
Determine the mean residence time t and the residence time distribution function E(t). Solution The mean residence time t is ∞
µ= t =
∫ t C(t )dt 0 ∞
∫ C(t )dt 0
(8-40)
706
Modeling of Chemical Kinetics and Reactor Design
and the E(t) function is E( t ) =
∞
C( t )
(8-54)
∫ C(t )dt 0
A plot of C(t) for the given conditions gives a trapezoidal shape as shown in Figure 8-20. Alternatively, ∞
5
8
11
0
2
5
8
∫ C(t )dt = ∫ (t − 2)dt + ∫ 3dt + ∫ (11 − t )dt ∞
integrating ∫ C(t)dt gives 0 5
11
t2 t2 I = − 2 t + 3[ t ] 85 + 11t − 2 8 2 2
= 18.0, which is the same value as the area of the trapezoidal shape.
Figure 8-20
Residence Time Distributions in Flow Reactors
707
To determine the mean residence time t , it is necessary to find the ∞ integral of ∫ C(t)dt over the given conditions as follows: 0
∞
5
8
11
0
2
5
8
∫ tC(t )dt = ∫ t(t − 2)dt + ∫ 3tdt + ∫ t(11 − t )dt 5
8
11
2
5
8
= ∫ ( t 2 − 2 t )dt + ∫ 3tdt + ∫ (11t − t 2 )dt Integrating gives 5 t 3 3 I = − t 2 + t 2 2 2 3
11
11t 2 t 3 + − 5 3 8 2
[ ]
8
= 117 The mean residence time t is ∞
µ=t=
∫ t C(t )dt 0 ∞
=
∫ C(t )dt
117 = 6.5 18
(8-40)
0
∞
The E(t) function is E(t) = C(t)/ ∫ C(t)dt for the following conditions. 0
t−2 18 3 C( t ) = E( t ) = 18 18 11 − t = 18 =0 =
when 2 ≤ t ≤ 5 when 5 ≤ t ≤ 8 when 8 ≤ t ≤ 11 elsewhere
708
Modeling of Chemical Kinetics and Reactor Design
RESIDENCE TIME DISTRIBUTION FOR A LAMINAR FLOW TUBULAR REACTOR Consider a steady unidimensional flow in a tubular reactor as shown in Figure 8-21 in the absence of either radial or longitudinal diffusion. The velocity u(r) is the parabolic distribution for a Newtonian fluid at constant viscosity, with the fluid in the center of the tube spending the shortest time in the reactor. The laminar velocity profile in Figure 8-21a is approximated by a series of annuli, within each of which the velocity is constant as illustrated in Figure 8-21b. Each annulus is considered to be a plug flow tubular reactor having its own space velocity. The velocities of the fluid elements at different radii are given by the parabolic velocity profile for fully developed laminar flow. The velocity is expressed as
Figure 8-21. Laminar flow reactor.
Residence Time Distributions in Flow Reactors
r 2 u( r ) = u O 1 − R where u(r) uO r R
= = = =
709
(8-64)
velocity at any radius r centerline velocity distance from the centerline of the pipe inside radius of the pipe
The average velocity through the tube is
u=
uO 2
(8-65)
Because u varies with r, the residence times of the various fluid elements will also vary with r. The time that it will take a fluid element to traverse the reactor of length L is t=
L = u( r )
L 2 r u O 1 − R
(8-66)
The average residence time t is
t=
2L uO
(8-67)
or the length L in terms of t is
L=
t uO 2
(8-68)
Combining Equations 8-66 and 8-68 gives t=
t uO
r 2 2 u O 1 − R
710
Modeling of Chemical Kinetics and Reactor Design
t r 2 = 1 − 2t R
(8-69)
The fluid at the centerline is moving the fastest, so this material will be the first to leave. It leaves at a time tmin given by
t min =
L L t = = uO 2 u 2
(8-70)
Therefore, F(t) = 0 for t <
t 2
(8-71)
The fraction of the volumetric flowrate that occurs in the region bounded by r = 0 and r = r is equal to F(t) where t is equal to the time necessary for a fluid element to traverse the reactor length at a given r.
F( t ) =
Volumetric flowrate between r = 0 and r = r Total volumetric flowrate r
or F( t ) =
∫ u(r )2 πrdr
0 R
(8-72)
∫ u(r )2 πrdr 0
Substituting Equation 8-64 into Equation 8-72 gives r 2 ∫ 1 − R r dr F( t ) = 0R r 2 ∫ 1 − R rdr r
0
(8-73)
Residence Time Distributions in Flow Reactors
711
Integrating Equation 8-73 gives r2 r4 − 2 2 2 4R 2 r 2 − r = F( t ) = R2 R4 R R − 2 4R 2
(8-74)
From Equation 8-69 2 r =1− t R 2t
(8-75)
Substituting Equation 8-75 into Equation 8-74 yields t t F( t ) = 1 − 2 − 1 − 2t 2t
F( t ) = 1 −
t 2t
2
(8-76)
Figure 8-22 shows the F(θ) curves for laminar flow in a tubular reactor and for other idealized flow patterns. The exit age distribution function E(t) for a laminar flow reactor is E( t ) = 0 E( t ) =
t2 2t 3
t 2 t t≥ 2
t<
(8-77)
The dimensionless form of the RTD function is E (θ ) = 0 E (θ ) =
for θ < 0.5
1 for θ ≥ 0.5 2θ 3
(8-78)
712
Modeling of Chemical Kinetics and Reactor Design
Figure 8-22. Curves for reactors with idealized flow patterns.
Figure 8-23 shows a plot for the exit age RTD. Note that not all velocity profiles in a tubular reactor are parabolic. Power law fluids have the profile n +1 r n u( r ) = u O 1 − R
(8-79)
where n ≥ 0 is known as the power law constant. Newtonian fluids are a special case of power law fluids and where n = 1, Equation 8-79 reduces to the parabolic profile. When n < 1, the fluid is known as pseudoplastic, and the velocity profile is thus flattened. When n > 1, the fluid is known as dilatant, and the velocity profile is sharper than the parabolic profile. The residence time distribution function for the power law fluids in a tubular reactor is 2n
( n + 1) t 2 nt ( n + 1)t ( n +1) F( t ) = 1 + for t > 1 − 3n + 1 (3n + 1)t (3n + 1)t
(8-80)
Residence Time Distributions in Flow Reactors
713
Figure 8-23. Residence time distribution for tubular laminar flow.
E- AND F-CURVES FOR A SERIES OF STIRRED TANK REACTORS Consider a series of well-stirred reactors each having the same volume, where the total volume is VR. Let C1, C2 . . . Cm . . . Cn be the concentrations leaving the successive stages of the CSTR. The unsteady state tracer balance on the mth stage is
uC m −1 = uC m + Vm
dC m dt
(8-81)
A model frequently employed to simulate the behavior of an actual reactor is a series of ideal stirred tank reactors as shown in Figure 8-24. The actual volume VR can be replaced by N identical stirred tank reactor whose total volume is the same as that of the actual reactor. That is: VR = NV
(8-82)
where V is the volume of each stirred tank. It is possible to determine the value of N that gives the best fit to the response curve of the actual reactor as described below. Consider a steady flow u m3/sec of fluid in and out of the first reactor volume
714
Modeling of Chemical Kinetics and Reactor Design
Figure 8-24. CFSTR in series.
V1. At time t = 0, a pulse of tracer is injected into the vessel that, when evenly distributed in the vessel, has a concentration C0. At any time t after the tracer is introduced, a material balance on the first reactor gives Input Rate – Output Rate = Rate of accumulation of tracer in the reactor 0 − uC1 = V1
dC1 dt
(8-83)
where C1 is the concentration of tracer in tank 1. Separating variables and integrating Equation 8-83 gives C1
∫
C0
dC1 u =− C1 V1
t
∫ dt 0
leading to C u ln 1 = − t V1 C0
(8-84)
Residence Time Distributions in Flow Reactors
or C1 = C 0 e − t
t1
715
(8-85)
where t = V1/u. Since Vi is the volume of a single reactor in the series, t i is the residence time in any one of the reactors, then ti =
V Vi V1 V2 V3 V = = = ...................... = N = R u u u u u Nu
(8-86)
The area under the C/CO versus t curve is t i , and from this the E-curve is
t1 E1 = e − t
t1
(8-87)
A material balance on the tracer in the second reactor where C1 enters and C2 leaves gives dC 2 dt
uC1 = uC 2 + V2
(8-88)
Substituting Equations 8-85 and 8-86, respectively, into Equation 8-88 yields COe − t
ti
= C2 + t i
dC 2 dt
(8-89)
Rearranging Equation 8-89 gives
dC 2 C 2 C O − t + = e dt ti ti
ti
(8-90)
Equation 8-90 is a first order differential equation, which is of the form dY/dx + P(x)y = Q(x). The integrating factor is e∫Pdx. In Equation 8-90, the integrating factor is 1
I.F. = e
∫ t i dt
t
= e ti
The solution after mathematical manipulation gives
716
Modeling of Chemical Kinetics and Reactor Design
C2 =
t COe − t ti
ti
(8-91)
A material balance on the tracer in the third reactor where C2 enters and C3 leaves gives uC 2 = uC 3 + V3
dC 3 dt
(8-92)
Substituting Equations 8-86 and 8-91 into Equation 8-92 and rearranging gives
dC 3 1 1 t + C3 = • CO e − t dt ti ti ti
ti
(8-93)
The integrating factor of Equation 8-93 is t
1
∫ dt Pdx I.F. = e ∫ = e ti = e ti The solution of Equation 8-93 is
C3 =
CO 2 − t t e 2 t i2
ti
(8-94)
For the exit-age distribution, the fraction of material exiting the system from the three CSTRs that are in the system between t and t + δt is ME(t)δt = uC3(t)δt or
E( t ) =
u C3 M
(8-95)
where M is the total amount of tracer injected. Substituting Equation 8-94 into Equation 8-95 yields
ME( t )δt = u
CO 2 − t t e 2 t i2
ti
δt
where by definition M/V = (u/u)CO, therefore
(8-96)
Residence Time Distributions in Flow Reactors
m 3 kg • sec• sec m 3
M = t i uC O
717
(8-97)
Equation 8-96 then becomes t i uC O E( t ) =
uC O t 2 − t e 2 t i2
ti
(8-98)
and the exit-age distribution function E(t) becomes E( t ) =
t2 −t e 2 t 3i
ti
(8-99)
For a series of CSTRs, the RTD for CSTR in series E(t) is
E( t ) =
1 t ( N −1) e−t N t i ( N − 1) !
ti
(8-100)
Because VR = NVi, then t i = t / N , where t is the total reactor volume divided by the flowrate u. In terms of dimensionless time θ, θ = t / t , t = Nt i . The exit age distribution function E(θ) is
E (θ ) =
N ( Nθ)N −1 − Nθ e (N − 1)!
(8-101)
Figure 8-25 shows the RTD of different numbers of tanks in series. As the number increases, the behavior of the system approaches that of a plug flow reactor. NB: CO for N tanks is usually defined as
M M = NVi VR
Similarly, for the step response, the output F-curve from a series of N ideal stirred tanks is F( t ) = 1 − e
− Nt t i
N −1 Nt 1 Nt 2 1 Nt 1 + (8-102) + + ... + (N − 1)! t i t i 2 ! t i
718
Modeling of Chemical Kinetics and Reactor Design
Figure 8-25. RTD curves for the tanks-in-series model.
In terms of dimensionless time θ, θ = t / t , t = Nt i , therefore
(Nθ)2 + . . . + (Nθ)N −1 + . . . F(θ) = 1 − e − Nθ 1 + Nθ + 2! (N − 1 ) ! These curves as N increases are illustrated in Figure 8-26.
(8-103)
Figure 8-26. The F-curve for the tanks-in-series model.
Residence Time Distributions in Flow Reactors 719
720
Modeling of Chemical Kinetics and Reactor Design
The number of tanks in series from the dimensionless variance (Equation 8-45) σ θ2 • σ θ2 from the tracer experiment is
σ θ2
σ2 = 2 = t
∞
∫ (θ − 1) E(θ)dθ 2
(8-45)
0
Expanding Equation 8-45 gives
σ θ2 =
∞
∞
∞
σ2 = ∫ θ 2 E(θ)dθ − 2 ∫ θ E(θ)dθ + ∫ E(θ)dθ t2 0 0 0 ∞
σ θ2 = ∫ θ 2 E(θ)dθ − 1 0
∞
= ∫ θ2 0
σ θ2 = =
σ θ2 =
N( Nθ)N −1 − Nθ e dθ − 1 (N − 1)!
(8-104)
∞
NN θ N +1e − Nθ dθ − 1 (N − 1)! ∫0 N N ( N + 1)! −1 (N − 1) ! N N + 2
(8-105)
1 N
(8-106)
The number of tanks in series is N=
1 t2 = 2 2 σθ σ
(8-107)
The number of tanks increases as the variance decreases, and the curve width or variance changes from σ θ2 = 1 for N = 1 to σ θ2 = 0 as
Residence Time Distributions in Flow Reactors
721
N → ∞. This indicates that the behavior of stirred tanks in series ranges from perfect mixing to plug flow.
RTD FUNCTIONS FOR CSTRs WHERE N IS NOT AN INTEGER It is often difficult to use Equations 8-101 or 8-103 to represent the response curve of an actual reactor where N is not an integer. Stokes and Nauman [16] have considered this situation, which is reviewed below. If the equivalent number of perfectly mixed stages N is not an integer, let i be an integer slightly smaller than N. A fraction 0 ≤ h < 1 is defined as N = i + h
(8-108)
The model consists of i + 1 stirred tanks in series, i of which have a common volume, VTotal/N, and one of which has a smaller volume hVTotal/N. For N > 1, the cumulative distribution F-functions are: − Nθ h F (θ ) = 1 − exp − exp( − Nθ) h − i h i
i −1 ( Nθ) j h i − j × ∑ 1 − j = 0 j! h − 1
(8-109)
for N > 1 and F(θ) = 1 – N exp(–Nθ)
(8-110)
for 1 > N > 0. The dimensionless variances are:
−h i h2 2 σ θ2 = −1 + 2 + 1 − h N2 N2
i −1
j= 0
−h
∑ ( j + 1)1 − 1 − h
i− j
(8-111)
for N > 1 and
σ θ2 =
2 −1 N
(8-112)
722
Modeling of Chemical Kinetics and Reactor Design
for 1 ≥ N > 0, where i j N θ σ2
= = = = =
number of tanks truncated to an integer index of summation number of tanks in series dimensionless residence time dimensionless variance
Equations 8-109, 8-110, 8-111, and 8-112 are reduced to an ordinary tanks-in-series model when N = i and h = 0. For the equivalent number of ideal CSTRs, N is obtained by minimizing the residual sum of squares of the deviation between the experimental F-curve and that predicted by Equation 8-109. The objective function is minimized from the expression Φ=
M
∑ [F E (θi ) − F M (θi )]
2
i =1
(8-113)
where FE(θi) = experimental F-curve data FM(θi) = predicted F-curve from Equation 8-109 A one-dimensional search optimization technique, such as the Fibonacci search, is employed to minimize Equation 8-113. A computer program (PROG81) was developed to estimate the equivalent number of ideal tanks N for the given effluent tracer response versus time data. Additionally, the program calculates the mean residence time, variance, dimensionless variance, dispersion number, and the Peclet number. The fractional tank extension model is simple to use and consists of only a single parameter to represent the non-ideality. It is useful for calculating reaction yields. If each of the tanks is a perfect mixer, the yield can be calculated from a set of algebraic equations. It is also useful in the direct fitting of experimental data. The model is well suited for visualizing various levels of micromixing. Zwietering [17] gives several examples for N = 2 and 3, which are extended to the fractional tank model. For N > 1, the true limit of maximum mixedness must be evaluated numerically. However, the greatest degree of micromixing corresponding to the physical model arises when each tank is a perfect mixer and the smallest tank is at the discharge end of the system. The drawback is that the individual extent of bypassing and
Residence Time Distributions in Flow Reactors
723
dead regions cannot be estimated quantitatively using this method. Macromixing, micromixing, and maximum mixedness models are reviewed in Chapter 9.
THE DISPERSION MODEL The design of chemical flow reactors depends on the overall rate at which the reaction proceeds, and the extent of backmixing occurring in the reactors. The first factor relates to the determination of the rate equations as reviewed in Chapter 2. The second factor, backmixing or dispersion, is used to represent the combined action of all phenomena, namely molecular diffusion, turbulent mixing, and non-uniform velocities, which give rise to a distribution of residence times in the reactor. The performance of the reactor and the degree of conversion attainable for a given feed and reactor volume differs from that which would be predicted assuming ideal plug flow (i.e., negligible diffusion), with the magnitude of the difference depending on the relative rates of diffusion and convection. Suppose a tracer pulse is introduced into the fluid entering a system. If the reactor is an ideal plug flow, the tracer pulse traverses through the reactor without distortion (Figure 8-27), and emerges to give the characteristic ideal plug flow residence impulse response as shown in Figure 8-28. If diffusion occurs, the tracer spreads away from the center of the original pulse in both the upstream and downstream directions. At various times from the injection, the tracer occupies positions in the reactor as illustrated in Figure 8-29. If the concentration of the tracer molecules in the reactor effluent are known, then the measured response will depend on the length of the reactor, the rate of diffusion, and mean fluid velocity. The response
Figure 8-27. Plug flow
724
Modeling of Chemical Kinetics and Reactor Design
Figure 8-28. RTD response for a plug flow reactor.
Figure 8-29. Dispersion of the tracer in a plug flow reactor.
begins when the tracer, which has diffused ahead of the centroid of the cloud, emerges from the reactor, builds up to a maximum when the bulk of the tracer emerges, and decreases as the trailing portion of the tracer signal passes the detector at the reactor outlet. Figure 8-30 illustrates the responses that may be measured for reactors of increasing length.
Residence Time Distributions in Flow Reactors
725
Figure 8-30. RTD curves at increasing tubular reactor length.
The distribution of tracer molecule residence times in the reactor is the result of molecular diffusion and turbulent mixing if the Reynolds number exceeds a critical value. Additionally, a non-uniform velocity profile causes different portions of the tracer to move at different rates, and this results in a spreading of the measured response at the reactor outlet. The dispersion coefficient D (m2/sec) represents this result in the tracer cloud. Therefore, a large D indicates a rapid spreading of the tracer curve, a small D indicates slow spreading, and D = 0 means no spreading (hence, plug flow).
726
Modeling of Chemical Kinetics and Reactor Design
Flow patterns in the reactor can vary greatly. To characterize backmixing, of the longitudinal dispersion number, D/uL, is often used, where D = longitudinal dispersion coefficient, m2/sec u = fluid velocity, m/sec L = length of reactor, m In a packed bed or flow in pipes, the dispersion number is also defined as D/ud, where d is the particle size in packed beds or the tube diameter in empty pipes. THE MODEL EQUATION Fick’s diffusion law is used to describe dispersion. In a tubular reactor, either empty or packed, the depletion of the reactant and nonuniform flow velocity profiles result in concentration gradients, and thus dispersion in both axial and radial directions. Fick’s law for molecular diffusion in the x-direction is defined by ∂C ∂2C =D 2 ∂t ∂x
(8-114)
where D is the longitudinal or axial dispersion coefficient, and it characterizes the degree of mixing during flow. Figure 8-31 shows a sketch of an annular element of this type tubular reactor. Consider a steady flow of reactant A to products at constant density through an element of radius r, width δr, and height δl in a tubular reactor at isothermal condition. Suppose that radial and axial mass transfer is expressed by Fick’s law, with (De)l and (De)r as effective diffusivities. The rate at which A reacts is (–rA), mol/m3 sec. A material balance on a tubular element of radii r and r + δr and height δl is carried out from
Input Output Disappearance = + + Accumulation Rate Rate by reaction A enters element l by convection and dispersion. The output term is the rate of passage of A through the cross-section at 1 + δl. The disappearance by reaction is the volumetric rate of disappearance (–rA) times the volume of the differential element 2πrδrδl.
Residence Time Distributions in Flow Reactors
(
)
Input rate:
2 πr • δr uC A,1 + N A,1 + 2 πr • δl • N A,r
Output rate:
2 πr • δr uC A,1+δl + N A,1+δl + (2 πr + δr ) • δl • N A,r +δr
Reactions term:
2πr • δr • δl( − rA ) over element
Accumulation rate:
δC 2πr • δr • δl A, over element δt
(
727
)
Figure 8-31. Annular element of a tubular reactor.
Input rate = 2πr • δr(uCA,l + NA,l) + 2πr • δl • NA,r
(8-115)
The flux NA is the sum of the diffusive flux JA with respect to the center of mass plus the contribution to the flux of A caused by the bulk mass movement.
728
Modeling of Chemical Kinetics and Reactor Design
NA = JA + NxA where JAx = –DAB(∂ρ/∂x). Output rate = 2πr • δr(uCA,l+δl + NA,l+δl) + (2πr + δr) • δl • NA,r+δr
(8-116)
Rate of disappearance = (–rA)over element δVR by reaction = 2πrδrδl (–rA)over element Accumulation rate = 2πrδlδr
δC A δt
(8-117) (8-118)
Combining Equations 8-115, 8-116, 8-117, and 8-118 gives ∂C A ∂C d uC A − (D e )l (2 πrδr ) − 2 π(D e )r δl d r A ∂l ∂r δC A =0 + 2 πr δl δr ( − rA ) + δt
(8-119)
Rearranging Equation 8-119 as δl → 0 gives ∂C ∂C A ∂2C A ∂C = (D e )l + (D e ) r r A − u A − ( − rA ) 2 ∂l ∂t ∂l ∂r
(8-120)
The effective axial dispersion coefficient (De)l and radial dispersion coefficient (De)r are assumed independent of concentration and position. Equation 8-120 is used for tubular flow of fluids in pipes and flow through packed beds where voidage is considered when defining (De)r and (–rA). Equation 8-120, which is analogous to Equations 6105 and 6-106 was employed with other homogeneous and heterogeneous systems in which axial symmetry can be assumed and where the flow does not deviate significantly from plug flow. However, the model cannot be used when the flow characteristics deviate considerably from plug flow such as in a CSTR, bubbling fluidized bed, and in two-phase flow of gas-liquid systems.
Residence Time Distributions in Flow Reactors
729
AXIAL DISPERSED PLUG FLOW MODEL When the effective radial dispersion coefficient (De)r can be neglected in comparison to the effective axial dispersion coefficient (D e) l, Equation 8-120 reduces ∂C A ∂2C A ∂C = (D e )l − u A − ( − rA ) 2 ∂t ∂l ∂l
(8-121)
This model is referred to as the axial dispersed plug flow model or the longitudinal dispersed plug flow model. (De)r can be neglected relative to (De)l when the ratio of column diameter to length is very small and the flow is in the turbulent regime. This model is widely used for chemical reactors and other contacting devices. In terms of the normalized coordinates t tu l θ= = , z= t L L
where L is the reactor length. Equation 8-121 then becomes ∂C A D e, l ∂ 2 C A ∂C A = − − ( − rA )t ∂θ uL ∂z 2 ∂z
(8-122)
DIMENSIONAL ANALYSIS OF THE DISPERSION MODEL It is often useful to write a model equation such as Equation 8-121 in terms of dimensionless variables. This introduces the Peclet number N Pe = uL/D e,l, which represents the ratio of characteristic dispersion time to characteristic convection time (residence time), and the Damköhler number, n −1 n −1 N Da = kC AO t = kC AO
L u
(8-123)
which represents the ratio of characteristic convection time (residence time) to the characteristic process (reaction) time. Assuming an nth order reaction at steady state condition, (∂C/∂θ) = 0, Equation 8-122 becomes
730
Modeling of Chemical Kinetics and Reactor Design
D e, l ∂ 2 C A ∂C A = + ( − rA t ) uL ∂z 2 ∂z
(8-124)
Where (–rA) = kCnA, Equation 8-124 gives
D e, l d 2 C A dC A n t = + kC A uL dz 2 dz or
1 d 2 C A dC A n = + kC A t N Pe dz 2 dz
(8-125)
Rearranging Equation 8-125 gives d 2CA dC n = N Pe A + kC A t 2 dz dz
(8-126)
When f = C A/C AO (the dimensionless concentration), Equation 8-126 gives C AO
or
d2f df n = N Pe C AO + kf n C AO t 2 dz dz
d2f df n −1 n = N Pe + ktC Ao f 2 dz dz
(8-127)
where the Damkhöler number is n −1 N Da = ktC AO
(8-128)
The dimensionless group De,l/uL is known as the dispersion number and is the parameter that measures the extent of axial dispersion. The degree to which axial dispersion influences the performance of a chemical reactor is determined by the value of the Peclet number (NPe). A high value of NPe corresponds to a slightly dispersed reactor. That is,
lim N Pe = lim D e, l → 0
uL D e, l
D e, l → 0
= ∞
Residence Time Distributions in Flow Reactors
731
signifying an ideal plug flow. Similarly, a low value of NPe,
lim N Pe = lim D e, l → ∞
uL D e, l
= 0
D e, l → ∞
represents a high degree of backmixing. The concentration of A is uniform throughout the reaction volume, and the dispersion model becomes a well-stirred tank model. Although the validity of the dispersion model depends to a great extent on the process, as a rule-of-thumb the dispersion model may be applied with confidence as long as NPe > 20. It should be used with great caution when NPe falls below this value. It has been shown that the tank-inseries (TIS) model gives a good representation of a wide range of mixing phenomena. Small values of N are appropriate for agitated tanks and large values for columns. In contrast, the dispersion plug flow (DPF) model depicts mixing in columns better than the TIS. However, this involves additional mathematical complexity. Generally, both the dispersion model and the tanks-in-series models are roughly equivalent, and either can be employed for representing flow in real vessels. Boundary Conditions of the Dispersion Model The two sets of boundary conditions for Equations 8-122 and 8-126 are: Closed ends
Open ends
∂C A ∂C uC AO = uC A − D e, l and A = 0 and ∂z z =1 ∂z z = 0
CA (±∞, t) = 0,
CA(0,t) = CA(t)
(8-129)
Closed ends apply to reactor operation and open ends are used with tracer studies when tracer is injected and sampled some distance from the ends of the vessel. Langmuir [18] first proposed the axial dispersion model and obtained steady state solutions from the following boundary conditions:
732
Modeling of Chemical Kinetics and Reactor Design
uC z → 0 − = uC z → 0 + − D e, l ∂C =0 ∂z z = L
∂C ∂z z → 0 +
for all t
(8-130)
Danckwerts [2] also obtained steady state solutions based on the same boundary conditions and various studies have since been performed by Taylor [19], Aris [20], and Levenspiel and Smith [21]. CORRELATION FOR AXIAL DISPERSION COEFFICIENTS A dimensionless group that frequently occurs in this context is the Bodenstein number expressed as N Bo = N Re • N Sc =
d t uρ ud t µ • = µ ρ D e, l D e, l
(8-131)
The dispersion model has been successfully employed in modeling the behavior of packed bed reactors. In this case, N Bo =
u • dp 6εD ′e,l
where u/ε dt dP u ε D ′e, l
= = = = = =
(8-132)
the average interstitial velocity in the bed pipe diameter mean particle diameter fluid velocity void fraction (porosity) of the bed effective dispersion coefficient based on actual crosssectional area available for fluid transport
The inverse of the Bodenstein number is εD ′e,l / u • d p , sometimes referred to as the intensity of dispersion. Himmelblau and Bischoff [5], Levenspiel [3], and Wen and Fan [6] have derived correlations of the Peclet number versus Reynolds number. Wen and Fan [6] have summarized the correlations for straight pipes, fixed and fluidized beds, and bubble towers. The correlations involve the following dimensionless groups:
Residence Time Distributions in Flow Reactors
N Pe =
D e, l εD ′e, l or ud ud p
N Re =
dtu ρ µ
=
N Sc = where d dP µ ρ Dmol
d p uρ µ
µ ρ D mol = = = = =
733
Peclet number
(8-133)
Reynolds number (empty tubes)
(8-134)
Particle Reynolds number (packed beds)
Schmidt number
(8-135)
the flow channel diameter for an empty tube mean particle diameter for packed beds fluid viscosity fluid density molecular diffusivity of the reactant (or tracer) in the fluid (Dmol ≈ 10–5 cm2/sec, for liquids, 1 cm2/sec for gases)
Knowing the viscosity and density of the reaction mixture, the flow channel diameter, void fraction of the bed, and the superficial fluid velocity, it is possible to determine the Reynolds number, estimate the intensity of dispersion from the appropriate correlation, and use the resulting value to determine the effective dispersion coefficient De,l or D ′e, l . Figures 8-32 and 8-33 illustrate the correlations for flow of fluids in empty tubes and through pipes in the laminar flow region, respectively. The dimensionless group D e, l / ud t = D e, l / 2 uR depends on the Reynolds number (NRe) and on the molecular diffusivity as measured by the Schmidt number (NSc). For laminar flow region, De.l is expressed by: D e, l = D mol +
or
u 2 d 2t 192 D mol
N • N Sc 1 1 = + Re N Pe N Re • N Sc 192
(8-136)
734
Modeling of Chemical Kinetics and Reactor Design
Figure 8-32. Correlation for the dispersion of fluids flowing in pipes. (Source: Levenspiel, O., Ind. Eng. Chem., 50, 343, 1958.)
The axial dispersion model also gives a good representation of fluid mixing in packed-bed reactors. Figure 8-34 depicts the correlation for flow of fluids in packed beds. Small Amount of Dispersion (De,l/uL < 0.01) For a relatively small amount of dispersion or large value of NPe, the tracer curve is very narrow. Consequently, the spreading of the
Residence Time Distributions in Flow Reactors
735
Figure 8-33. Correlation of axial dispersion coefficient for flow of fluids through pipes in laminar flow region (NRe < 2,000). (Source: Wen, C. Y. and Fan, L. T., Models for Flow Systems and Chemical Reactors, Marcel Dekker Inc., 1975.)
tracer curve does not significantly change as it passes the measuring point. As a good approximation, it is symmetrical and Gaussian as shown in Figure 8-35. The axial dispersion model is expressed as
2 −(1 − θ) 1 C= exp 4 D e , l D e, l 2 π uL uL
(8-137)
Levenspiel [3] has given a family of Gaussian curves, and the equations representing these curves are given in Table 8-7. Large Amount of Dispersion (De,l/uL > 0.01) For a large amount of dispersion or small value of NPe, the pulse response is broad, and it passes the measurement point slowly enough for changes to occur in the shape of the tracer curve. This gives a non-symmetrical E-curve.
736
Modeling of Chemical Kinetics and Reactor Design
Figure 8-34. Correlation of dispersion to Reynolds number. (Source: Levenspiel, O., Ind. Eng. Chem., 50, 343, 1958.)
Figure 8-35. Guassian response to pulse input for small dispersion.
Two types of boundary conditions are considered, the closed vessel and the open vessel. The closed vessel (Figure 8-36) is one in which the inlet and outlet streams are completely mixed and dispersion occurs between the terminals. Piston flow prevails in both inlet and outlet piping. For this type of system, the analytic expression for the E-curve is not available. However, van der Laan [22] determined its mean and variance as
Residence Time Distributions in Flow Reactors
737
Table 8-7
E(θ) = tE( t ) =
E( t ) =
2 − − θ 1 ( ) exp D e ,l D e ,l 4 4 π uL uL 1
−( L − ut ) 2 u3 exp 4 πD e,l L 4 D e ,l uL
tE =
V L = or θE = 1 υ υ
σ θ2 =
σ 2t D D L = 2 e,l or σ 2 = 2 e,3l uL u t2
Figure 8-36. Flow conditions for closed-closed system.
tE = t =
σ θ2
t t υ V or θ E = E = E = 1 υ t V
σ2 D D = t = 2 e , l − 2 e , l uL uL t
− uL 1 − e D e,l
2
(8-138)
For an open vessel (Figure 8-37), diffusion can occur across the system boundaries. It is assumed that the dispersion coefficient De,l
738
Modeling of Chemical Kinetics and Reactor Design
Figure 8-37. Flow conditions for open-open system.
or the Peclet number NPe is the same from just before the inlet to just beyond the outlet. The open vessel represents a convenient experimental device as a section of a long pipe. Levenspiel and Smith [21] derived the mean and variance in the E(θ) as:
E (θ ) =
2 −(1 − θ) 1 exp 4 θ D e , l D e, l 4 π uL uL
or E( t ) =
−( L − ut )2 u exp 4 πD e, l 4 D e, l
(8-139)
The moments of the solution are: θE =
tE D = 1 + 2 e , l uL t
or t E =
σ θ2 =
D V 1 + 2 e, l υ uL
2 D e, l σ 2t D e, l = 2 + 8 uL t2 uL
(8-140)
Residence Time Distributions in Flow Reactors
739
If De,l/uL is small enough so that (De,l/uL)2 can be neglected, then σ θ2 = 2 or
D e, l uL
D e, l 1 2 = σθ uL 2
(8-141)
Open-Closed and Closed-Open Vessels van der Laan [22] developed equations for the mean and variance in terms of the dispersion coefficient De,l/uL as θE OC = θE CO = 1 +
σ θ2 OC = σ θ2 CO =
D e, l D V or t E OC = t E CO = 1 + e, l υ uL uL
σ 2t CO t2
=
σ 2t OC t2
2 D D = 2 e, l + 3 e, l uL uL
(8-142)
Table 8-8 summarizes the results of the cases discussed above including the boundary conditions, the expression for C(θ) at z = 1, and the mean and variance for C(θ). The criterion for the validity of Equation 8-141 is NPe k 1.0. A rough rule-of-thumb is NPe > 10. If this condition is not satisfied, the correct equation depends on the boundary conditions at the inlet and outlet. A procedure for determining dispersion coefficient D e,l is as follows: 1. Measure the outlet response to a tracer impulse injected at the inlet. 2. Calculate the mean µ and the variance σ2 using Equations 8-40 and 8-43, respectively. 3. Estimate the Peclet number from Equation 8-141. If the value of NPe is 10 or greater, accept it. Otherwise, use a refinement of the theory, which accounts for the boundary conditions at the outlet, or formulate another model. 4. Determine the mean (superficial) fluid velocity, u , as the volumetric flowrate divided by the flow channel cross-section. 5. Estimate the dispersion coefficient De,l from the definition of the Peclet number.
Open-Open
Closed-Closed
+Closed-Open
Gaussian
Case
1+ θ 2
Levenspiel and Smith
dC =0 dz
z = + ∞,
− N Pe (1 − θ) 2 exp 4θ
1 N Pe 2 πθ
0.5
Otake and Kunigita
Complex expression
Villermaux and van Swaaij
0.5
− N Pe (1 − θ) 2 exp − N Pe exp( N Pe ) erfc( A ) 4θ
N A = Pe θ
0.5
dC =0 dz
∂C(θ) = 0 θ ≤ 0, C(θ) = 0 ∂z
1 ∂C(θ) N Pe ∂z
1 dC N Pe dθ
N Pe πθ
− N Pe 2 exp 4 (1 − θ) Levenspiel
1 N Pe 2 π
Reduced concentration at z = 1, C(θ) at z = 1
z = −∞,
z =1
z = 0 δ(θ) = C(θ) −
θ ≤ 0, C = 0
z → ∞, C → 0
z = 0, δ(θ) = C(θ) −
—
Boundary conditions
1+
1+
2 N Pe
1
1 N Pe
1
2 8 + N Pe N 2Pe
2 N Pe − 2 + 2 e − N Pe N 2Pe
2 3 + N Pe N 2Pe
2 N Pe
Moments Variance σ2θ mean θ
Table 8-8 Comparison of solutions of the axially dispersed plug flow model for different boundary conditions
740 Modeling of Chemical Kinetics and Reactor Design
Residence Time Distributions in Flow Reactors
741
Figure 8-38 shows the residence time distributions of some commercial and fixed bed reactors. These shapes can be compared with some statistical distributions, namely the Gamma (or Erlang) and the Gaussian distribution functions. However, these distributions are represented by limited parameters that define the asymmetry, the peak,
Figure 8-38. Residence time distributions of some commercial and fixed bed reactors. The variance, equivalent number of CSTR stages, and Peclet number are given for each reactor. (Source: Walas, S. M., Chemical Process Equipment—Selection and Design, Butterworths, 1990.)
742
Modeling of Chemical Kinetics and Reactor Design
and the shape in the vicinity of the peak. The parameters are the moments, variance, skewness, and kurtosis. Wen and Fan [6] have developed moments of RTDs of various flow models. The Gamma distribution function for non-integral values is given by E( t )gamma =
N N N −1 θ exp( − Nθ) Γ(N)
(8-143)
The value of N is the only parameter in Equation 8-143. It can be computed from the RTD experimental data from its variance (Equation 8-107). Gaussian Distribution Function A well-known statistical distribution is the normal or Gaussian distribution and is expressed by f (θ ) =
−(θ − 1)2 1 exp −∞≤ θ≤ +∞ 2 σ 2π 2σ
(8-144)
Because only positive values of θ are of concern in the RTD, this function is normalized by dividing the integral from 0 to ∞ with the result −(θ − 1)2 E(θ)gauss = f (σ ) exp 2 2σ
where f (σ ) =
(8-145)
2
πσ 2 1 + erf 1 σ 2
(
)
(8-146)
EFFECT OF DISPERSION ON REACTOR PERFORMANCE The axial dispersion plug flow model is used to determine the performance of a reactor with non-ideal flow. Consider a steady state reacting species A, under isothermal operation for a system at constant density; Equation 8-121 reduces to a second order differential equation:
Residence Time Distributions in Flow Reactors
D e, l d 2 C A dC A − − ( − rA )t = 0 uL dz 2 dz
743
(8-147)
For a first order reaction (–rA) = kCA, and Equation 8-147 is then linear, has constant coefficients, and is homogeneous. The solution of Equation 8-147 subject to the boundary conditions of Danckwerts and Wehner and Wilhelm [23] for species A gives
CA = 1− XA = C AO
(1 + a )2 exp a
2
D where a = 1 + 4 kt e, l uL
1 uL 4a exp 2 D e, l (8-148) −a uL uL 2 − (1 − a ) exp D e, l 2 D e, l
0.5
In terms of the Peclet number NPe, Equation 8-148 becomes 1 4a exp N Pe 2 CA = 1− XA = (8-149) a C AO (1 + a )2 exp N Pe − (1 − a )2 exp −a N Pe 2 2 4 kt where a = 1 + N Pe
0.5
Equations 8-148 and 8-149 give the fraction unreacted CA/CAO for a first order reaction in a closed axial dispersion system. The solution contains the two dimensionless parameters, NPe and kt . The Peclet number controls the level of mixing in the system. If NPe → 0 (either small u or large De,l), diffusion becomes so important that the system acts as a perfect mixer. Therefore, CA 1 = as NPe → 0 C AO 1 + kt
(8-150)
744
Modeling of Chemical Kinetics and Reactor Design
As NPe→ ∞ (large u or small De,l), the system behaves as a piston flow reactor so that CA = e − kt as NPe → ∞ C AO
(8-151)
Levenspiel and Bischoff [24] compared the fraction unreacted by the dispersion model to the solution with that for plug flow: CA = 1 − e − kt = 1 − e − kL u C AO
(8-152)
They further determined the ratio of the dispersion reactor volume to the plug flow reactor volume required to accomplish the same degree of conversion for several values of the dimensionless dispersion parameter De,l/uL. Figure 8-39 shows the results of Equation 8-147
Figure 8-39. Comparison of real and plug flow reactors for the first order reaction A → Products [24].
Residence Time Distributions in Flow Reactors
745
for a first order reaction. The abscissa is (CA)outlet/(CA)inlet or 1 – XA, and the ordinate is the ratio of the dispersed plug flow reactor volume to the volume of an ideal plug flow reactor (PFR), which will be required to achieve the same conversion. The extent to which axial dispersion influences the reactor performance is determined by the value of a dimensionless group (Figure 8-32) as De,l/ud. For high conversions and large De,l/uL, significantly larger reactors are required than are predicted by a plug flow analysis. At large De,l/uL, the use of the dispersion model is inappropriate; therefore, a lower segment of Figure 8-39 is feasible for design calculations. Figure 8-39 shows that as the rate of dispersion increases, the reactor volume required to achieve a fixed conversion increases from a minimum value for ideal plug flow (De,l = 0) to a maximum value for a perfect mixer (De,l = ∞). Figure 8-40 shows the results for second order kinetics, which is also most appropriate when De,l/uL is small. For a small dispersion number (De,l/uL K 1) and (De,l/uL • kt K 1), CA k 2σ2 2 D = exp − kt + ( kt ) e, l = exp − kt + 2 C AO uL
(8-153)
C 2 D or ln A = − kt + ( kt ) e, l uL C AO
(8-154)
Using Equation 8-154 for the same reactor space time and volume gives C A, dispersion 2 D ln = ( kt ) e, l uL C A, plug flow
(8-155)
Equation 8-155 shows that the conversion in the dispersion reactor will always be less than that of the plug flow reactor (CA,dispersion > CA,plug flow). In the case where the effluent composition is fixed instead of the reactor size, Equations 8-152 and 8-154 can be manipulated to show that for small De,l/uL,
L dispersion L plug flow
=
Vdispersion Vplug flow
= 1 + ( kt )
D e, l uL
(8-156)
746
Modeling of Chemical Kinetics and Reactor Design
Figure 8-40. Comparison of real and plug flow reactors for second order reactions [24].
COMPARISION OF TANK IN SERIES (TIS) AND DISPERSION PLUG FLOW (DPF) MODELS Both the tank in series (TIS) and the dispersion plug flow (DPF) models require tracer tests for their accurate determination. However, the TIS model is relatively simple mathematically and thus can be used with any kinetics. Also, it can be extended to any configuration of compartments with or without recycle. The DPF axial dispersion model is complex and therefore gives significantly different results for different choices of boundary conditions.
Residence Time Distributions in Flow Reactors
747
For a large dispersion (small NPe), the TIS model is preferred. The TIS model provides a mechanism that is readily visualized and often used. The Gamma and dispersion models can be related by equating the variances of their respective E(θ) functions. This gives σ θ2 = =
[
]
2 N Pe − 1 + exp( − N Pe ) N 2Pe 1 N erlang
(8-157)
For both large and small values of NPe,
N erlang =
N Pe 2
(8-158)
RESIDENCE TIME DISTRIBUTION IN A STATIC MIXER Static mixers, as reviewed in Chapter 7, contain mixing elements enclosed in a tubular housing through which radial mixing is achieved. They redistribute fluid across the flow channel and consequently rearrange temperature and composition distributions. They are often used to promote mixing in laminar flow systems thus having a pronounced effect on the RTD. A major unknown variable in reactor design is the scale of imperfection in the flow pattern. This is caused by various factors such as the existence of stagnant regions, channeling of fluid through the system, or recycling of the fluid within the vessel. It is important that these anomalies are considered during scale-up to avoid errors in the final design. Therefore, complete knowledge of what happens to every molecule as it passes through the vessel is necessary to design an effective mixer. This can be acquired by having a complete velocity distribution of the molecules in the mixer. Computational fluid dynamics (CFD) is an effective tool in analyzing the velocity distribution and other pertinent parameters in a static mixer. CFD is also being recognized as an effective tool in enhancing the performance of mixers and reactors, which is reviewed in Chapter 10.
748
Modeling of Chemical Kinetics and Reactor Design
A practical method of predicting the molecular behavior within the flow system involves the RTD. A common experiment to test nonuniformities is the stimulus response experiment. A typical stimulus is a step-change in the concentration of some tracer material. The stepresponse is an instantaneous jump of a concentration to some new value, which is then maintained for an indefinite period. The tracer should be detectable and must not change or decompose as it passes through the mixer. Studies have shown that the flow characteristics of static mixers approach those of an ideal plug flow system. Figures 8-41 and 8-42, respectively, indicate the exit residence time distributions of the Kenics static mixer in comparison with other flow systems. The dispersed plug flow model has been successfully applied to describe the flow characteristics in the Kenics mixer. The complex flow behavior in the mixer is characterized by the one-parameter. The Peclet number, NPe, is defined by: N Pe =
uL D e, l
(8-159)
where u = average linear flow velocity in the mixer L = length of the mixer De,l = axial dispersion coefficient For an ideal plug flow system, there is no axial dispersion, hence De,l = 0 and NPe → ∞. In contrast, for an ideal backmix flow system, De,l → ∞ and NPe = 0. The Peclet number for all flow systems lies somewhere between these ideal conditions. A flow system with NPe > 100 is considered to be plug flow, and as indicated in Figure 8-42, the step response curve of the Kenics mixer corresponds to an average Peclet number of 145. Therefore, it is inferred that the unit is nearly a plug flow device. Additionally, the plug flow characteristics are attributed to the thorough radial mixing, which reduces the spread of the residence times. The Kenics mixer has been shown to provide thorough radial mixing. This results in a reduction in radial gradients in velocity, composition, and temperature. Because the unit possesses nearly plug flow characteristics, both temperature and product quality controls are achieved.
Residence Time Distributions in Flow Reactors
749
Figure 8-41. E-Function: Exit residence time distrubtion for the Kenics Mixer and other flow systems.
Example 8-5
Using the experimental residence time distribution data of Levenspiel and Smith in Example 8-2, determine the number of ideal tanks N, the variance, dispersion number, and Peclet number. Solution The computer program PROG81 estimates the equivalent number of ideal tanks N for the given experimental residence time distribution
Figure 8-42. F-Function: Exit residence time distrubtion for the Kenics Mixer and other flow systems.
750 Modeling of Chemical Kinetics and Reactor Design
Residence Time Distributions in Flow Reactors
751
data by minimizing Equation 8-103. The input data are the t versus E(t) data, upper and lower limits of the parameter, and maximum number of Fibonacci searches. The lower limit of the parameter is zero. The upper limit is an arbitrary number as high as 10 or 25, depending on the shape of the E-curve and how closely it approaches plug flow behavior. Table 8-9 gives the detailed computer results and Figure 8-43 shows FExp(θ) and FModel(θ) versus θ.
Table 8-9 Tracer concentration versus time data
752
Modeling of Chemical Kinetics and Reactor Design
Table 8-9 (continued)
753
RTD Functions: E(θ), FExp, FModel
Residence Time Distributions in Flow Reactors
Dimensionless Time Figure 8-43. RTD simulation E(θ), FExp(θ), and FModel(θ) versus θ.
Example 8-6
Using the experimental residence time distribution data of Hull and von Rosenberg in Example 8-3, determine the number of ideal tanks N, the variance, dispersion number, and Peclet number. Solution Computer program PROG81 determines the number of tanks, the variance, dispersion number, and the Peclet number from Hull and von Rosenberg data. The results of the simulation suggest that about three stirred tanks in series are equivalent to the RTD response curve. Figure 8-44 shows the shows E(θ), FExp(θ), and FModel(θ) versus θ. Example 8-7
Tracer impulse data of a commercial hydrodesulfurizer (Sherwood, A Course in Process Design, MIT Press, 1963) with 10 mm catalyst pellets are given in the following table.
Modeling of Chemical Kinetics and Reactor Design
RTD Functions: E(θ), FExp, FModel
754
Dimensionless Time Figure 8-44. RTD simulation E(θ), FExp(θ), and FModel(θ) versus θ.
Time
Concentration
17.5 10.0 12.5 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 37.5 40.0 42.5 45.0 47.5 50.0
0.0 1.2 4.5 14.2 40.7 46.4 32.9 23.5 16.6 11.8 8.5 6.0 4.1 2.6 1.5 0.4 0.0
Determine the various response functions.
Residence Time Distributions in Flow Reactors
755
Solution An Excel spreadsheet (Example8-7.xls) was used to determine the various RTD functions and the computer program PROG81 was used to simulate the model response curve with the experimental data. The results show the equivalent number of ideally mixed stages (nCSTRs) for the RTD is 13.2. The Gamma distribution function from Equation 8-143 is: E( t )Gamma =
N N N −1 θ exp( − Nθ) Γ(N)
E( t )Gamma =
13.213.2 12.2 θ exp( −13.2θ) Γ (13.2)
(8-143)
RTD Functions: E(θ), FExp, FModel
The dispersion number is 0.039 and the Peclet number (NPe) is 26. Figure 8-45 shows FExp(θ) and FModel(θ) versus θ.
Dimensionless Time Figure 8-45. RTD simulation E(θ), FExp(θ), and FModel(θ) versus θ.
Modeling of Chemical Kinetics and Reactor Design
RTD Functions: E(θ), F(θ), I(θ), Exp(θ)
756
Dimensionless Time Figure 8-46. Residence time distrubtion functions versus dimensionless time.
GLOSSARY Age of a fluid element: The age of a fluid element at a given instant of time is the time that elapses between the element’s entrance into the vessel and the given instant. The age is equal to the residence time for those molecules that are just leaving the vessel. Closed vessel: One in which the rate of diffusion across the vessel entrance and exit boundaries is negligible compared to the rate of convective motion across the boundaries. Closed end vessel: One in which the inlet and outlet streams are completely mixed and dispersion occurs only between the terminals. At the inlet where z = 0, uCo = [uC – De,1(∂C/∂z)]z=0; at the outlet where x = L, (∂C/∂z)z=0. These are referred to as Danckwerts’ boundary conditions.
Residence Time Distributions in Flow Reactors
757
Clump: A collection of molecules small enough to occupy no more than a microscopic volume in a reactor, but large enough for the concept of concentration to be meaningful. Concentration: The main types are: Cδ, the effluent from a vessel with impulse input of tracer; Co = m/Vr, the initial mean concentration resulting from impulse input of magnitude m; Cu, the effluent from a vessel with a step input of magnitude Cf. Dispersion: The movement of aggregates of molecules under the influence of a gradient of concentration, temperature, etc. The effect is represented by Fick’s law with a dispersion coefficient substituted for molecular diffusion coefficient. The rate of transfer = –De(∂C/∂z). Impulse: An amount of tracer injected instantaneously into a vessel at time zero. The symbol mδ(t – a) represents an impulse of magnitude m injected at time t = a. The effluent concentration resulting from an impulse input is Cδ. Intensity of segregation: A measure of the difference in concentration between neighboring clumps of fluid, IS = C ′A2 / CA (1 – CA ), where CA is the time-averaged concentration and C ′A is the fluctuating component of concentration A. Life expectation, λ: Of a molecule or aggregate in a vessel at a particular time is the period that it will remain in the vessel before ultimately leaving. The distribution of life expectancies is identical with that of residence times, E(λ) = E(t). Macromixing: The phenomenon whereby residence times of clumps are distributed about a mean value. Mixing on a scale greater than the minimum eddy size or minimum striation thickness, by laminar or turbulent motion. Maximum mixedness: Exists when any molecule that enters a vessel immediately becomes associated with those molecules with which it will eventually leave the vessel. This occurs with those molecules that have the same life expectation. A state of maximum mixedness is associated with every residence time distribution (RTD). Maximum mixedness model: The fluid in a flow reactor that behaves as a micro fluid. Mixing of molecules of different ages occurs as early as possible.
758
Modeling of Chemical Kinetics and Reactor Design
Mean residence time: The average time spent by the molecules in a vessel. It is the first moment of the effluent concentration from a vessel with impulse input and is defined by ∞
t=
∫ t Cδ dt 0 ∞
∫ Cδ dt 0
Micromixing: Mixing among molecules of different ages (i.e., mixing between macrofluid clumps). Mixing on a scale smaller than the minimum eddy size or minimum striation thickness by molecular diffusion. Mixing, ideal or complete: A state of complete uniformity of composition and temperature in a vessel. In a flow system, the residence time distribution is exponential, ranging from zero to infinity. Open end vessel: One in which there are no discontinuities (abrupt changes) in concentration at the inlet and outlet where both bulk and dispersion flow occur. The boundary conditions are C = Co when z = 0 and δC/δz = 0 when z = ∞. Peclet number: NPe = uL/De, where u is a linear velocity, L is a linear dimension, and D e is the dispersion coefficient. In packed beds, NPe = udP/De, where u is the interstitial velocity and dP is the particle diameter. Perfect tracer: Tracer molecules behave identically with the process fluid molecules within the process unit. Plug flow: A condition in which all effluent molecules have had the same residence time. Pulse: A type of input in which the concentration of tracer in the input stream is changed suddenly, maintained at a non-zero value for a definite period, then changed to the original value and maintained that way for the period of interest. When the pulse is of constant magnitude it is called a square pulse. Residence time distribution (RTD): The time that elapses from when the element enters the vessel to when it leaves. Residence time distribution functions: These give information about the fraction of the fluid that spends a certain time in a process vessel.
Residence Time Distributions in Flow Reactors
759
In the case of tracer from a vessel that contained an initial average concentration Co, the area under a plot of E(t) = Ceffluent/Co between the ordinates at t1 and t2 is the fraction of the molecules that have residence times in this range. In the case of step constant input of concentration Cf to a vessel with zero initial concentration, the ratio F(t) = Ceffluent/Cf at t1 is the fraction of molecules with residence time less than t1. Tracer: A substance that is used for measuring the residence time distribution in a vessel. Usually, it is inert and used in small concentrations so as not to change the physical properties of the process fluid appreciably, and analyzable for accuracy. Scale of segregation: A measure of the average distance between “clumps” of the same component in a mixture. Segregration: The tendency of the contents of a reactor to behave as a macrofluid. Segregrated flow: Occurs when all molecules that enter together also leave together. A state of segregation is associated with every RTD. Each aggregate of molecules reacts independently of every other aggregate, as in an individual batch reactor. Segregrated flow model: The fluid in a flow reactor is assumed to behave as a macrofluid. Each clump functions as a miniature batch reactor. Mixing of molecules of different ages occurs as late as possible. Skewness: The third moment of a residence time distribution, which is expressed by: ∞
γ 3 ( t ) = ∫ ( t − t ) E( t )dt 3
0
It is a measure of asymmetry. Step Input: An input in which the concentration of tracer is changed to some constant value Cf at time zero and maintained at this level indefinitely. For example, Cfu(t – a) represents a step of magnitude Cf beginning at t = a. The resulting effluent concentration is Cu. Striation thickness: Average distance between adjacent interfaces of materials to be mixed by a laminar mechanism.
760
Modeling of Chemical Kinetics and Reactor Design
Variance: The second moment of the RTD. There are two terms: one of absolute time, σ2(t), and the other of dimensionless time, θ = t / t , σ θ2 = σ 2 ( t ) / t 2 ∞
σ (t ) = 2
∫ (t − t ) 0
∞
2
C δ dt
∫ Cδ dt
=
∞
∫ (t − t ) E(t )dt 2
0
0
σ θ2 =
∞
σ 2 (t ) = ∫ (θ − 1)2 E(θ)dθ 2 t 0
REFERENCES 1. Mac Mullin, R. B. and Weber, M., Jr., Trans. Am. Inst. Chem. Eng., 31, 409, 1935. 2. Danckwerts, P. V., Chem. Eng. Sci., 2, pp. 1–18, 1953. 3. Levenspiel, O., Chemical Reaction Engineering, 3rd ed., John Wiley & Sons, New York, 1999. 4. Levenspiel, O. and Bischoff, K. B., Adv. Chem. Eng., 4, 95, 1963. 5. Himmelblau, D. M. and Bischoff, K. B., Process Analysis and Simulation, Deterministic Approach, John Wiley & Sons, New York, 1968. 6. Wen, C. Y. and Fan, L. T., Models for Flow Systems and Chemical Reactors, Marcel Dekker, Inc., New York, 1975. 7. Shinnar, R., “Use of Residence and Contact Time Distributions in Reactor Design,” Chapter 2, pp. 63–149 of Chemical Reaction and Reactor Engineering, Carberry, J. J. and Varma, A., Eds., Marcel Dekker, New York, 1987. 8. Danckwerts, P. V., Chem. Eng. Sci., Vol. 9, pp. 78–79, 1958. 9. Naor, P. and Shinnar, R., I & EC Fundamentals, pp. 278–286, 1963. 10. Yim, S. S. S. and Ayazi, S. P., “Residence Time Distribution in a Rotary Flow Through Device, Fluid Mixing V,” Inst. ChemE. Symp. Series, No. 140, pp. 191–201, 1996. 11. Al-Taweel, A.M., et al., Trans. IChemE, Vol. 74, Part A, pp. 456– 461, May 1996. 12. Carpenter, N. G. and Roberts, E. P. L., Trans. IChemE, Vol. 77, Part A, pp. 212–217, May 1999.
Residence Time Distributions in Flow Reactors
761
13. Coker, A. K., “Mathematical Modelling and a Study of Flow Patterns in Cylindrical Nozzle,” M.Sc. Thesis, Aston University, 1979. 14. Coker, A. K., “A Study of Fast Reactions in Nozzle Type Reactors,” Ph.D. Thesis, Aston University, 1985. 15. Missen, R. W., Mims, C. A., and Saville, B. A., Introduction to Chemical Reaction Engineering and Kinetics, John Wiley & Sons, 1999. 16. Stokes, R. L. and Nauman, E. B., The Canadian J. of Chem. Eng., Vol. 48, pp. 723–725, 1970. 17. Zwietering, Th., N., Chem. Eng. Sci., 11, 1, 1959. 18. Langmuir, I., J. Am. Chem. Soc., 30, 1742, 1908. 19. Taylor, G. I., Proc. Roy Soc. (London) 219A, 186, 1953; 225A, 473, 1954a; 223A, 446, 1954b. 20. Aris, R., Chem. Eng. Sci., 9, 266, 1959. 21. Levenspiel, O. and Smith, W. K., Chem Eng. Sci., 6, 227, 1957. 22. van der Laan, E. T., Chem. Eng. Sci., 7, 187 1958. 23. Wehner, J. and Wilhelm, R. H., Chem. Eng. Sci., 6, 89, 1956. 24. Levenspiel, O. and Bischoff, K. B., Ind. Eng. Chem., 51, 1431 1959; 53, 313, 1961.
762
Modeling of Chemical Kinetics and Reactor Design
CHAPTER 9
Models for Non-Ideal Systems INTRODUCTION In a non-ideal system, the distribution functions exhibit various forms. Therefore, knowledge of these distributions for a given system is important. By comparing the curves corresponding to ideal systems, it is possible to determine the type of ideal behavior that a system most closely resembles. If the differences are small, the system can be treated as one of the ideal models discussed in Chapter 5. However, a large difference may imply a complex system, in which case modification will be required to reflect the real behavior of the system. The techniques for measuring the RTD by means of a tracer offer a diagnostic approach in analyzing the structure of flow in continuous systems. The tank-in-series (TIS) and the dispersion plug flow (DPF) models can be adopted as reactor models once their parameters (e.g., N, De,l and NPe) are known. However, these are macromixing models, which are unable to account for non-ideal mixing behavior at the microscopic level. This chapter reviews two micromixing models for evaluating the performance of a reactor— the segregrated flow model and the maximum mixedness model—and considers the effect of micromixing on conversion.
BASICS OF NON-IDEAL FLOW Three main factors affect either the interaction of fluids in a system or the flow pattern. These are: • How early or late mixing of material occurs in the system. • The state of aggregation of the flowing material, its tendency to clump, and for a group of molecules to move about together. • The residence time distribution of material that is flowing through the system. 762
Models for Non-Ideal Systems
763
The fluid elements of a single flowing stream can mix with each other either early or late in their flow through the system. This is especially important with two reactants entering a vessel. Two extreme states of aggregation of a process are referred to as macrofluid and microfluid (Figure 9-1). In a macrofluid, molecules move together in clumps. The clumps are distributed in residence times, but all the molecules within a clump have the same age. In contrast, the clumps are dispersed in a microfluid because all the molecules move independently of one another regardless of age. The RTD in a system is a measure of the degree to which fluid elements mix. In an ideal plug flow reactor, there is no mixing, while in a perfect mixer, the elements of different ages are uniformly mixed. A real process fluid is neither a macrofluid nor a microfluid, but tends toward one or the other of these extremes. Fluid mixing in a vessel, as reviewed in Chapter 7, is a complex process and can be analyzed on both macroscopic and microscopic scales. In a non-ideal system, there are irregularities that account for the fluid mixing of different
Figure 9-1. Two extreme states of fluid micromixing.
764
Modeling of Chemical Kinetics and Reactor Design
ages at the microscopic level. The RTD does not account for how fluid elements at the microscopic scale interact with each other. There is an obvious distinction between macromixing, or a set of mechanisms associated with the RTD, and micromixing, which results from the interactions between the fluid elements. Macromixing defines the variation in the residence time experienced by molecules flowing through a flow system, while micromixing relates to the concentration history experienced by the molecules as they traverse through the system. The conversion in a system can be determined from the RTD with knowledge of the macromixing process. Generally, the performance of non-ideal flow systems can be determined from known parameters, such as: • • • •
The kinetics of the system The RTD of fluid in the system The earliness or lateness of fluid mixing in the system The nature of the fluid (i.e., whether a micro or macro fluid) in the system
SEGREGRATED FLOW MODEL In a mixing process where complete segregation occurs, the fraction of fluid elements with residence times (t, t + dt) is E(t)dt, and the average exit composition in the vessel is defined by: mean concentration of reactant in the = CA = ∆lim t→0 exit stream
fraction of exit concentration of reactant remaining stream which is ∑ in an element of age of age between all elements of exit stream between t and t + dt t and t + dt
(9-1)
Consider a segregated flow system as illustrated in Figure 9-2, with a known RTD, in which a reaction A → products. The disappearance rate of A is (–rA) = (rA)(CA)
(9-2)
Since the fluid flows in clumps and is completely segregated by age (i.e., each clump behaves like a batch reactor), it is possible to determine the reactant concentration in every clump for a constant density fluid as:
Models for Non-Ideal Systems
765
Figure 9-2. Reactor with segregated flow.
dC − A = ( rA ) dt clump
(9-3)
Rearranging Equation 9-3 and integrating yields C A ,clump
∫
C AO
− dC A =t rA
(9-4)
Therefore, CA,clump is a function of time for all nth order reactions. Using Equation 9-3 for the reactant concentration remaining in an element that has been in the reactor for a time t, E(t)dt is the fraction of the exit stream with ages between t and t + dt. Equation 9-1 then becomes ∞
CA = ∫ C A, clump ( t ) E( t ) dt
(9-5)
0
The reactant conversion XA is XA = 1 – CA / C AO . In terms of the fractional conversion, Equation 9-5 becomes ∞ C CA 1 − XA = = ∫ A E( t ) dt C AO 0 C AO clump
(9-6)
A zero order reaction in a batch reactor gives CA kt = 1− C AO C AO
(9-7)
766
Modeling of Chemical Kinetics and Reactor Design
Substituting Equation 9-7 into Equation 9-6 and integrating gives
(
CA kt = 1− 1 − e − C AO C AO C AO
kt
)
(9-8)
For a first order reaction, we have
CA = e − kt C AO clump
(9-9)
∞
and
or
CA = e − kt E( t )dt C AO ∫0
CA ≅ C AO
∑ e − kt E(t ) ∆t
(9-10)
The residence time density function E(t) is E( t ) = 1t e − t
t
(8-25)
Substituting Equation 8-25 into Equation 9-10 gives ∞
CA 1 = e − kt • e C AO ∫0 t ∞
−t t
dt
1
1 − k+ t = ∫ e t dt t0
(9-11)
Integrating Equation 9-11 by parts (i.e., ∫wdv = wv – ∫vdw) yields
CA 1 = C AO 1 + kt
(9-12)
Equation 9-12 is identical to that derived in Chapter 5. There appears to be two methods for determining the conversion in a
Models for Non-Ideal Systems
767
perfectly mixed reactor. In Chapter 5, complete mixing in the reactor was assumed, and no RTD was explicitly used. Here, the first order reaction gives identical results when the RTD is used as specified by Equation 8-25. For a second order reaction of a single reactant, CA 1 = C AO clump 1 + ktC AO
(9-13)
The segregated flow model equation gives −t C ∞ 1 1 1 − XA = A = ∫ • e t dt C AO 0 1 + ktC AO t
(9-14)
where α = l/ktCAO and θ = t / t . Equation 9-14 becomes ∞ −(α + θ ) C e 1 − X A = A = αe α ∫ d(α + θ) = αe α ei(α ) C α + θ AO 0
(9-15)
∞
where Ei(x) ≡ exponential integral ∫x (e–y/y)dy. Equation 9-15 gives the conversion expression for the second order reaction of a macrofluid in a mixed flow. An exponential integral, ei(α), which is a function of α, and its value can be found from tables of integrals. However, the conversion from Equation 9-15 is different from that of a perfectly mixed reactor without reference to RTD. An earlier analysis in Chapter 5 gives −1 + 1 + 4 kC AO t CA = 2 kC AO t C AO
(5-245)
For an nth order reaction, the conversion in a batch reactor is: C 1 (1− n ) n −1 1 − X A = A = 1 + ( n − 1)C AO kt C AO
[
]
(9-16)
For an nth order reaction of a macrofluid, Equation 9-16 is substituted into Equation 9-6 to give
768
Modeling of Chemical Kinetics and Reactor Design ∞
−t
1 t C n −1 (1− n ) e 1 − X A = A = ∫ 1 + ( n − 1)C AO • dt C AO 0 t
[
]
(9-17)
For N-stirred tanks in series, the conversion is expressed by ∞
N
− k + t CA 1 NN = N t N −1 e t dt ∫ C AO t ( N − 1)! 0
CA 1 1 = N = C AO kt [1 + kt i ]N 1 + N
(8-160)
Complete segregation represents an extreme form of mixing on a molecular scale. Molecules enter mixed and leave mixed, but no mixing takes place within the system. Any RTD is possible in this state. Complete segregated systems can be modeled as piston flow reactors in parallel, as shown in Figure 9-3 or as single piston flow reactor with side exits as in Figure 9-4. Other residence time distributions have some maximum possible level of micromixing, referred to
Figure 9-3. Models for segregated reactors: Piston flow elements in parallel.
Models for Non-Ideal Systems
769
Figure 9-4. Single-piston flow element with side exits.
as maximum mixedness. Figure 9-5 shows an illustration of micromixing. The abscissa (macromixing) measures the breadth of the residence time distribution. It is zero for piston flow, fairly broad for the exponential distribution of stirred tanks, and broader yet for situations with stagnancy and bypassing. The ordinate (micromixing) varies from none to complete and it measures the effects of micromixing. This can be negligible for piston flow and have maximum importance for stirred tank reactors. Soundly designed reactors will fall in the normal region bounded by three apexes: piston flow, perfect mixing, and complete segregation with an exponential distribution.
Figure 9-5. Schematic representation of mixing space. (Source: Nauman, E. G., Chemical Reactor Design, John Wiley & Sons, 1987.)
770
Modeling of Chemical Kinetics and Reactor Design
A real system must lie somewhere along a vertical line in Figure 9-5. Performance is within the upper and lower points on this line; namely maximum mixedness and complete segregation. Equation 9-10 gives the complete segregation limit. The complete segregation model with side exits and the maximum mixedness model are discussed next.
COMPLETE SEGREGATION MODEL WITH SIDE EXITS Consider a plug flow reactor with side exits (Figure 9-6) through which portions of the flow leave. Molecules are classified as they traverse within the system according to their ages λ (i.e., the life expectancy of the fluid in the reactor at that point), implying that mixing occurs as late as possible. A material balance on an elemental volume ∆V of the reactor between ages λ and λ + dλ follows. Input of A by flow in vessel at λ = u[1 – f(λ)]CA(λ)
(9-18)
Output of A by flow in vessel at λ + dλ = u[1 – F(λ + dλ)]CA (λ + dλ)
(9-19)
Output from the side exit = uCAE(λ)dλ
(9-20)
where the volume of fluid with a life expectancy between λ and λ + dλ is
Figure 9-6. A plug flow reactor with side exits.
Models for Non-Ideal Systems ∞
[
]
∆V = ∫ u 1 − F(λ ) dλ − 0
771
∞
∫ u[1 − F(λ )] dλ = u[1 − F(λ )]∆λ
λ + dλ
(9-21)
The rate of loss of substance A in this volume is = (–rA)∆V = (–rA)u[1 – f(λ)]∆λ
(9-22)
A balance on component A between λ and λ + dλ gives
Input of A by flow in vessel at λ
rate of loss of output of A by output of A by substance A = flow in vessel + flow through + by reaction sides of vessel at λ + dλ in ∆V
which is: u[1 – F(λ)]CA(λ) = u[1 – F(λ + dλ)]CA(λ + dλ) + uCAE(λ)dλ + (–rA)u[1 – F(λ)]∆λ
(9-23)
Rearranging Equation 9-23 and dividing by u as ∆λ → 0 gives:
0=
{[
]
}+C
d 1 − F( λ ) C A ( λ ) dλ
A
(λ )E(λ ) + (− rA )[1 − F(λ )]
(9-24)
Equation 9-24 gives
dC A = − ( − rA ) dλ
(9-25)
Each fluid element containing molecules of the same age during its passage through the reactor can be considered as a small batch reactor. The mean concentration overall fluid elements at the reactor outlet is the expected concentration of all fluid elements over the RTD.
772
Modeling of Chemical Kinetics and Reactor Design
MAXIMUM MIXEDNESS MODEL (MMM) Upon entering the reactor, the molecules of the feed immediately mix and become associated with the molecules in whose company they will eventually leave. Figure 9-7 shows a plug flow with multiple inlets whose flow pattern is given by the same RTD. Zwietering [1] developed the MMM as represented by a plug flow in which the feed enters continuously and incrementally along the reactor length. Consider the material balance of reactant A around the differential volume between λ and λ + dλ. rate of loss of Input of A by Input of A by output of A substance A flow in vessel + flow through = by flow in + by reaction the side at λ vessel at λ at λ + dλ in ∆V
Input of A by flow in vessel at λ + dλ = u[1 – F(λ + dλ)]CA(λ + dλ)
(9-26)
Input of A by flow through the side at λ = [uE(λ)∆λ]CAO
(9-27)
Figure 9-7. A plug flow reactor with side entry.
Models for Non-Ideal Systems
Output of A by flow in vessel at λ = u[1 – F(λ)]CA(λ)
773
(9-28)
The rate of loss of substance A in this volume is = (–rA)∆V = (–rA)u[1 – F(λ)]∆λ
(9-29)
The steady-state material balance on A gives u[1 – F(λ + dλ)]CA(λ + dλ) + [uE(λ)∆λ]CAO = u[1 –F(λ)]CA(λ) + u(–rA)[1 – F(λ)]∆λ
(9-30)
Rearranging Equation 9-30 and dividing by u gives: [1 – F(λ + dλ)]CA(λ + dλ) + E(λ)∆λCAO – [1 – F(λ)]CA(λ) – (–rA)[(1 – F(λ)]∆λ = 0
(9-31)
Taking the limits as ∆λ → 0 gives: E(λ )C AO +
{[
]
} − (− r )[1 − F(λ)] = 0
d 1 − F( λ ) C A ( λ )
[
dλ
]
or C AO E(λ ) + 1 − F(λ )
(9-32)
A
dC A (λ ) − C A E(λ ) − ( − rA ) 1 − F(λ ) = 0 (9-33) dλ
[
]
Rearranging Equation 9-33 yields: dC A (λ ) (C AO − C A ) E(λ ) + − ( − rA ) = 0 dλ 1 − F( λ )
[
]
(9-34)
Equation 9-34 does not use an initial value of CA as a boundary condition. Instead, the usual boundary condition associated with Equation 9-34 is
Lim λ→0
dC A =0 dλ
(9-35)
774
Modeling of Chemical Kinetics and Reactor Design
The outlet concentration from a maximum mixedness reactor is found by evaluating the solution to Equation 9-34 at λ = 0; CAout = CA(0). The analytical solution to Equation 9-34 is rather complex; for reaction order n > 1, the (–r A) term is usually non-linear. Using numerical methods, Equation 9-34 can be treated as an initial value problem. Choose a value for CAout = CA(0) and integrate Equation 9-34. If CA(λ) achieves a steady state value, the correct value for CA(0) was guessed. Once Equation 9-34 has been solved subject to the appropriate boundary conditions, the conversion may be calculated from CAout = CA(0).
EFFECT OF MICROMIXING ON CONVERSION As stated earlier, the actual state of micromixing lies between two extremes. However, further details are extremely difficult to use either theoretically or experimentally. Kramers and Westerterp [2] gave results for the extreme case of a perfectly macromixed reactor with various reactions occurring. Figures 9-8 and 9-9 illustrate a comparison between the segregated flow and complete mixing for n = 0 and n > 1, respectively. It can be seen in Figure 9-9 that the differences between
Figure 9-8. Conversion for a zero order reaction in a CSTR and a PFT. (Source: Wen, C. Y. and L. T. Fan, Models for Flow Systems and Chemical Reactors, Marcel Dekker Inc., 1975.)
Models for Non-Ideal Systems
775
Figure 9-9. Conversion for isothermal elementary reactions in a CSTR [2].
the levels of micromixing are small. For a first order reaction (or a series of first order reactions), micromixing has no effect on the reactor performance. Therefore, conversion is predicted exactly by the segregated flow model (Equation 9-10). Micromixing decreases conversion for reaction orders greater than 1 and increases for orders less than 1. The segregated flow model, consequently, predicts an upper bound on conversion for n > 1 and a lower bound for n < 1. Several types of models have been developed for intermediate levels of micromixing with arbitrary macromixing RTD. Weinstein and Adler [3], Villermaux and Zoulalain [4], and Ng and Rippin [5] have proposed a model that divides the reactor into two environments: one in a segregated state and the other in a maximum mixedness state. The fraction in each state can be fitted to the actual reactor data, which are then correlated. For bimolecular reaction, the maximum difference between the conversion corresponding to complete segregation and that corresponding to maximum mixedness can be as much as 50%. Tsai et al. [6] have developed the two-environment model, which is an empirical modification of the original two-environment model. It considers material transfers from the entering environment to the leaving environment at a rate that is proportional to the amount of
776
Modeling of Chemical Kinetics and Reactor Design
material remaining in the entering environment. They showed that the reversed two-environment is more appropriate for the growth in a flow reactor than other micromixing models. Chen and Fan [7] inferred that a reversed two-environment model is more representative of polymer reactors. In this case, the reactants initially enter the maximum mixedness region, but become segregated as polymerization increases the viscosity and decreases diffusivities. Industrial reactors generally operate adiabatically. Cholette and Blanchet [8] compared adiabatic plug flow reactor to the CSTRmm. For exothermic reactions, they inferred that the performance of a CSTRmm is better than that of a plug flow reactor at low values of conversion, and vice-versa at high values of conversion. They further showed that the design considerations for endothermic reactions are similar to those for isothermal reactions. For isothermal autocatalytic and adiabatic reactions, the effects of macromixing and micromixing on the conversions are different from those for isothermal elementary reactions. Figures 9-10 and 9-11 compare the performances of these reactions under the two extreme states of micromixing. Worrel and Eagleton [9] performed mixing and segregation studies in a CSTR. They deduced that the maximum mixedness conversion is attained rapidly as impeller speed is increased. However, the effect of micromixing on the conversion was negligible.
Figure 9-10. Conversion for autocatalytic in a CSTR and a PFT. (Source: Wen, C. Y. and L. T. Fan, Models for Flow Systems and Chemical Reactors, Marcel Dekker Inc., 1975.)
Models for Non-Ideal Systems
777
Figure 9-11. Conversion for a first order, adiabatic reaction in a CSTR and a PFT. (Source: Wen, C. Y. and L. T. Fan, Models for Flow Systems and Chemical Reactors, Marcel Dekker Inc., 1975.)
Their studies also showed the importance of the reacting system kinetics for better design operation of CSTR reactors. Generally, empirical models involving micromixing should be viewed with caution because it is difficult to obtain valid correlations for the parameters in the absence of sound experimental data. Also, a model may not provide a unique measure of micromixing except for the specific system being studied. Micromixing is a complex phenomenon, which cannot be easily characterized by one or more adjustable parameters. A model with few parameters might provide an excellent fit for one reaction and a poor fit for another reaction that occurs in the same vessel. A comprehensive discussion and analyses on micromixing are provided by Nauman and Buffham [10], and Wen and Fan [11].
778
Modeling of Chemical Kinetics and Reactor Design
Example 9-1
Consider the data of Hull and von Ronsenberg in Example 8-3 for mixing in a fluidized bed. Suppose the solids in the fluidized bed were not acting as a catalyst, but were actually reacting according to a first order rate law (–r) = kC, k = 1.2 min–1. Compare the actual conversion with that of an ideal plug flow. Solution For the plug flow system, the concentration of unreacted reactant with respect to A is determined by CA/C AO = e –kt where t is the mean residence time; t = 2.5 min (see Example 8-3) and CA/CAO = e–kt = e–(1.2)(2.5) = 0.05. The conversion, XA = 1 – CA/CAO = 0.95 or 95% conversion. Using the macromixing Equation 9-10, an Excel spreadsheet (Example9-1.xls) was developed that gives CA / C AO = 0.11. In terms of conversion, X A = 0.89 or 89% conversion. Thus, the simulation of the actual reactor suggests that it is less efficient than a plug flow reactor. This may be due to several factors such as channeling or bypassing of the fluid in the reactor. If the reactor had been designed using the usual plug flow model, the actual performance in the plant would be far less than expected. For a higher conversion in the reactor, some modifications would be required to remedy the nonideal flow. Example 9-2
The flow through a reactor is 10 dm3/min. A pulse test gave the following concentration measurements at the outlet. t(min)
c × 105
t(min)
c × 105
0 0.4 1.0 2.0 3 4 5 6 8 10
0 329 622 812 831 785 720 650 523 418
15 20 25 30 35 40 45 50 60
238 136 77 44 25 14 8 5 1
Models for Non-Ideal Systems
779
1. What is the volume of the reactor? Calculate and plot E(θ), F(θ), and I(θ) versus θ. 2. If the reactor is modeled as a tank-in-series (TIS) system, how many tanks are needed to represent this reactor? 3. If the reactor is modeled by a dispersion model, what is the Peclet number (NPe)? 4. What is the reactor conversion for a first order reaction with k = 0.1 min–1 for a. The tank in series model b. The segregation model c. The dispersion model d. Plug flow e. A single CFSTR Solution An Excel spreadsheet (Example9-2.xls) was developed for the RTD functions and the parameters. The calculated mean residence time is 9.878 min, and thus the volume of the reactor is V = t•u = 9.878 × 10 = 98.8 dm3 Figure 9-12 shows plots of E(θ), F(θ), and I(θ) versus θ. Assuming that the reactor is modeled as TIS, the number N is determined as
N=
1 σ θ2
where σ2θ is the dimensionless variance. The value from the spreadsheet is σ2θ = 0.765. Therefore, the number of tanks required to represent this reactor is N = 1.31. Assuming that the reactor is modeled by a dispersion model using the closed boundary conditions, the Peclet number is determined by 2
σθ =
(
2 2 − 2 1 − e − N Pe N Pe N Pe
)
(8-161)
780
Modeling of Chemical Kinetics and Reactor Design
Figure 9-12. Plots of E(θ), F(θ), and I(θ) versus θ.
Expressing Equation 8-161 as a polynomial gives
f ( N Pe ) = σ θ2 −
(
2 2 1 − e − N Pe + N Pe N 2Pe
)
(8-162)
As an alternative to using the computer program (PROG16), Equation 8-162 can be expressed in a spreadsheet. Using the GOAL-SEEK command from the Tools menu (Appendix B) from the Excel spreadsheet menu to determine the Peclet number gives f(NPe) = 0. This function is incorporated in the spreadsheet. The computed Peclet number is NPe = 0.8638. For a first order reaction with k = 0.1 min–1, the following conversions were determined: For the TIS model,
XA = 1 −
1 N kt + 1 N
From the spreadsheet, XA = 0.521 or 52.1%.
(8-160)
Models for Non-Ideal Systems
781
The segregation model gives: CA ≅ C AO
∑ e − kt E(t ) ∆t
(9-10)
XA = 0.47 or 47% For the dispersion model, the conversion is determined by Equation 8-149 as 1 4a exp N Pe 2 CA = 1 − XA = (8-149) −a a C AO (1 + a )2 exp N Pe − (1 − a )2 exp N Pe 2 2 4 kt where a = 1 + N Pe
0.5
Using the value of NPe = 0.86, the calculated conversion from the spreadsheet is XA = 0.53 or 53%. The conversion for the plug flow is expressed as: X A = 1 − e − kt
XA = 0.627 or 62.7% For a single CSTR
XA =
=
kt 1 + kt
(0.1)(9.878) 1 + (0.1)(9.878)
= 0.497 or 49.7%. A summary of the conversion is given as:
782
Modeling of Chemical Kinetics and Reactor Design
Flow systems
Conversion, XA (%)
Plug flow reactor Dispersion Tank-in-series Segregated model A single CSTR
62.7 52.6 52.1 47.0 49.7
REFERENCES 1. Zwietering, T. N., Chem. Eng. Sci., 11, 1–15, 1959. 2. Kramers, H. and Westerterp, K. R., Elements of Chemical Reactor Design and Operation, Academic Press, New York, 1963. 3. Weinstein, H. and Adler, R. J., Chem. Eng. Sci., 22, 65, 1967. 4. Villermaux, J. and Zoulalain, A., Chem. Eng. Sci., 24, 1513, 1969. 5. Ng, D. Y. C. and Rippin, D. W. T., “The effect of incomplete mixing on conversion in homogeneous reactions,” Proc. 3rd Europ. Symp. of Chem. Eng., Amsterdam, Netherlands, 1964. 6. Tsai., B. I., Fan, L. T., Erickson, L. E., and Chen, M. S. K., J. Appl Chem. Biotechnol., 21, 307, 1971. 7. Chen, M. S. K. and Fan, L. T., Can. J. Chem. Eng., 49, 704–708, 1971. 8. Cholette, A. and Blanchet, J., Can. J. Chem. Eng., 39, 192, 1961. 9. Worrel, G. R. and Eagleton, L. C., Can. J. Chem. Eng., 39, 254, 1964. 10. Nauman, E. B. and Buffham, B. A., Mixing in Continuous Flow System, John Wiley & Sons, 1983. 11. Wen, C. Y. and Fan, L. T., Models for Flow Systems and Chemical Reactors, Marcel Dekker, Inc., 1975.
Application of Computational Fluid Dynamics
783
CHAPTER TEN
Application of Computational Fluid Dynamics and Computational Fluid Mixing in Reactors INTRODUCTION Computational fluid dynamics (CFD) is the analysis of systems involving fluid flow, energy transfer, and associated phenomena such as combustion and chemical reactions by means of computer-based simulation. CFD codes numerically solve the mass-continuity equation over a specific domain set by the user. The technique is very powerful and covers a wide range of industrial applications. Examples in the field of chemical engineering are: • • • • • • •
Polymerization Multiphase flow in reactors (e.g., bubble column) Reaction modeling Sedimentation Separation Complex pipeline network Mixing
The numerical solution of the energy balance and momentum balance equations can be combined with flow equations to describe heat transfer and chemical reactions in flow situations. The simulation results can be in various forms: numerical, graphical, or pictorial. CFD codes are structured around the numerical algorithms and, to provide easy assess to their solving power, CFD commercial packages incorporate user interfaces to input parameters and observe the results. CFD 783
784
Modeling of Chemical Kinetics and Reactor Design
codes contain three main elements, namely, a pre-processor, a solver, and a post-processor. PRE-PROCESSOR The pre-processor consists of inputting a problem into a CFD program using a friendly interface, which is transformed into a suitable format for the solver. The user activities at this stage involve: • Defining the geometry of the region of interest: the computational domain. Some CFD packages now allow geometries prepared in CAD packages to be imported directly into the CFD code, thus reducing pre-processing time as many plant designs are already available in CAD packages. • Grid generation by subdividing the domain into a number of smaller non-overlapping subdomains. This creates a grid (or mesh) of cells (or control volumes or elements). • Selecting the physical and chemical phenomena that need to be modeled. • Defining fluid properties. • Specifying appropriate boundary conditions of cells that coincide with or touch the domain boundary. The accuracy of a CFD program is greatly influenced by the number of cells in the grid. The larger the number of cells, the more accurate the solution. Additionally, the cost of computer hardware and calculation time combined with the accuracy of a solution depends on the preciseness of the grid. SOLVER The three modes of numerical solution techniques are finite difference, finite element, and spectral methods. These methods perform the following steps: • Approximation of the unknown flow variables by means of simple functions. • Discretization by substitution of the approximations into the governing flow equations and subsequent mathematical manipulations. • Solution of the algebraic equations.
Application of Computational Fluid Dynamics
785
The commercial CFD codes use the finite volume method, which was originally developed as a special finite difference formulation. The numerical algorithm consists of the following steps: • Integrating the governing equations of fluid flow over all the finite control volumes of the solution domain. • Discretizating by substituting the various finite-difference type approximations for the terms in the integrated equation representing flow processes, which converts the integral equations into a system of algebraic equations. • Solving the algebraic equations by an iterative method. POST-PROCESSOR The results of CFD packages are obtained by several means, due to the versatile data visualization tools that are now incorporated in many workstations. The results can be of several forms: • • • • • •
Vector plots Two- or three-dimensional surface plots Particle tracking Line and shaded contour plots Domain geometry and grid display View manipulation (translation, rotation, scaling, and color postscript output)
Successful utilization of CFD packages depends on understanding the physical and chemical phenomena that must be considered for a typical problem. Good modeling skills are essential when making necessary assumptions so that the complexity of the problem can be reduced at the same time as retaining the principal features of the problem. The correct assumptions often govern the quality of the information generated by CFD. An adequate knowledge of the numerical solution algorithm is also needed. The mathematical concepts used to determine the success of such algorithms are convergence, consistency, and stability. Convergence is the property of a numerical method that produces a solution, which approaches the exact solution as the grid spacing, control volume size, or element size is reduced to zero. Consistent numerical schemes are systems of algebraic equations that can be
786
Modeling of Chemical Kinetics and Reactor Design
demonstrated to be the same as the original governing equation as the grid spacing tends to zero. Finally, stability deals with damping the errors as the numerical method proceeds. An unstable technique causes round-off errors in the initial data resulting in extraneous oscillations and divergence. The principal steps in the simulation must be outlined. This includes allocating memory, defining the domain, setting the cells, choosing the physical model and boundary conditions, defining the physical constants, saving the case file, running the program, and saving the data. At the end of the simulation, the user must decide whether the results are adequate, as it is impossible to assess the validity of the models of physics and chemistry that are incorporated in CFD codes. Thus, the final results must always be validated by an experiment. CFD is a powerful additional problem-solving tool, and validation of the code requires highly detailed information concerning the boundary conditions of a problem. Experimental techniques such as laser doppler velocimetry (LDV), digital particle image velocimetry (DPIV), and gamma-ray computed tomography (GRCT) are modern tools employed for flow analysis and visualization. These techniques can be used to validate CFD results. Mixing of single and multiphase fluids in stirred tanks is a common operation in chemical process industries. Proper knowledge of fluid flow is essential for scale-up, equipment design, process control, and economic factors. Computational fluid mixing (CFM) is a powerful tool that can be used to model fluid flows of different impeller designs in stirred tank reactors. CFM models enable designers to visualize mixing as it occurs in the vessel, thus allowing the designer to select the best agitator to achieve the desired process performance. In this chapter, the theory of fluid flow in three dimensions, fluid mixing in stirred tank reactors employing CFM, and CFD tools are reviewed. The combination of these tools and experimental techniques helps to provide accurate point values of time-averaged and fluctuating velocities, as well as the time-average and semi-instantaneous flow fields in stirred tanks. At the end of this chapter is a review on the use of CFD in enhancing the performance of reactors.
THEORY AND FLUID FLOW EQUATIONS The governing equations of fluid flow represent mathematical statements of the conservation of mass, known as the continuity equation:
Application of Computational Fluid Dynamics
787
• The mass of fluid is conserved. • The rate of change of momentum equals the sum of the forces on a fluid particle (Newton’s second law). • The rate of change of energy is equal to the sum of the rate of heat addition to and the rate of work done on a fluid particle (first law of thermodynamics). The fluid is regarded as a continuum, and its behavior is described in terms of macroscopic properties such as velocity, pressure, density and temperature, and their space and time derivatives. A fluid particle or point in a fluid is the smallest possible element of fluid whose macroscopic properties are not influenced by individual molecules. Figure 10-1 shows the center of a small element located at position (x, y, z) with the six faces labelled N, S, E, W, T, and B. Consider a small element of fluid with sides δx, δy, and δz. A systematic account
Figure 10-1. Fluid element for the conservation of mass, momentum, and energy.
788
Modeling of Chemical Kinetics and Reactor Design
of changes in the mass, momentum, and energy of the fluid element due to fluid flow across its boundaries and to the action of sources inside the elements where necessary, results in the fluid flow equations. All fluid properties are functions of space and time, namely ρ(x, y, z, t), p(x, y, z, t), T(x, y, z, t), and u(x, y, z, t) for the density, pressure, temperature, and velocity vector, respectively. The element under consideration is so small that fluid properties at the faces can be expressed accurately by the first two terms of a Taylor series expansion. For example, the pressure at the E and W faces, which are both at a distance 1/2δx from the element center, is expressed as p–
∂p 1 ∂p 1 • ∂x and p + • δx ∂x 2 ∂x 2
Conservation of mass. The mass balance for the fluid element can be expressed as: Rate of increase of mass Net rate of flow of mass = in fluid element into fluid element
The rate of increase of mass in the fluid element is: ∂ (ρδx δy δz) = ∂ρ δx δy δz ∂t ∂t
(10-1)
Accounting for the mass flowrate across a face of the element, which is given by the density product, area, and velocity component normal to the face (Figure 10-2), the net rate of flow of mass into the element across its boundaries is given by: ∂(ρu) 1 ∂(ρu) 1 ρu − ∂x 2 δx δy δz − ρu + ∂x 2 δx δy δz ∂(ρv) 1 ∂(ρv) 1 + ρv − δy δx δz − ρv + δy δx δz ∂y 2 ∂y 2 ∂(ρw) 1 ∂(ρw) 1 + ρw − δz δx δy − ρw + δz δx δy ∂z 2 ∂z 2
(10-2)
Application of Computational Fluid Dynamics
789
Figure 10-2. Mass flows in and out of the fluid element.
Flows that are directed into the element give an increase of mass in the element and are assigned a positive sign. The flows leaving the element are assigned a negative sign. Equating the rate of increase of mass into the element across its faces (Equation 10-2), yields: ∂(ρu) 1 ∂(ρu) 1 ∂ρ δx δy δz = ρu − δx δy δz − ρu + δx δy δz ∂t ∂x 2 ∂x 2 ∂(ρv) 1 ∂(ρv) 1 + ρv − δy δx δz − ρv + δy δx δz ∂y 2 ∂y 2 ∂(ρw) 1 ∂(ρw) 1 + ρw − δz δx δy − ρw + δz δx δy ∂z 2 ∂z 2
(10-3)
790
Modeling of Chemical Kinetics and Reactor Design
Dividing by the element volume δxδyδz gives
∂ρ ∂ + (ρu) + ∂ (ρv) + ∂ (ρw) = 0 ∂t ∂x ∂y ∂z
(10-4)
or, in a more compact vector, Equation 10-4 is:
∂ρ + div (ρu) = 0 ∂t
(10-5)
Equation 10-5 is the unsteady, three-dimensional mass conservation or continuity equation at a point in a compressible fluid. The first term on the left side is the rate of change in time of the density (mass per unit volume). The second term describes the net flow of mass leaving the element across its boundaries and is called the convective term. For an incompressible fluid (i.e., constant density) Equation 10-4 becomes ∂u ∂v ∂w + + =0 ∂x ∂y ∂z
(10-6)
or div u = 0
(10-7)
An equation for conservation of momentum can be derived by considering Newton’s second law, which states that the rate of change of momentum of a fluid particle equals the sum of the forces on the particle. That is, Rate of increase Sum of forces of momentum of = on fluid particle fluid particle The rates of increase of x, y, and z momentum per unit volume of a fluid particle are given by
ρ
Du Dt
ρ
Dv Dt
ρ
Dw Dt
The two types of forces on fluid particles are classified as:
Application of Computational Fluid Dynamics
791
• Body forces: gravity force, centrifugal force, Coriolis force electromagnetic force. • Surface forces: pressure forces, viscous forces. It is possible to determine the x-component of the momentum equation by setting the rate of change of x-momentum of the fluid particle equal to the total force in the x-direction on the element due to surface stresses plus the rate of increase of x-momentum due to sources, which gives:
ρ
Du ∂( − p + τ xx ) ∂τ yx ∂τ zx = + + + SMx Dt ∂x ∂y ∂z
(10-8)
The y-component and z-component of the momentum equation are given by
(
)
ρ
∂τ zy Dv ∂τ xy ∂ − p + τ yy = + + + SMy ∂x ∂y ∂z Dt
(10-9)
ρ
Dw ∂τ xz ∂τ yz ∂( − p + τ zz ) = + + + SMz Dt ∂x ∂y ∂z
(10-10)
The sign associated with the pressure is opposite to that associated with the normal viscous stress. The usual sign convention assumes that a tensile stress is the positive normal stress so that the pressure, which by definition has compressive normal stress, has a negative sign. The effects of the surface stresses are accounted for explicitly, and source terms SMx, SMy, and SMz include contributions due to the body process only. For example, the body force due to gravity would be modeled by SMx = 0, SMy = 0, and SMz = –ρg. The Navier-Stokes equation with viscous stresses for the x, y, and z directions are given by: ρ
Du −∂p ∂ ∂u ∂ ∂u ∂v = + 2 µ + λ div u + µ + Dt ∂x ∂t ∂x ∂y ∂y ∂x +
∂ ∂u ∂w µ + + SMx ∂z ∂z ∂z
(10-11)
792
ρ
Modeling of Chemical Kinetics and Reactor Design
Dv −∂p ∂ ∂u ∂v ∂ ∂v = + + + + λ div u 2µ µ Dt ∂y ∂x ∂y ∂x ∂y ∂y +
ρ
∂ ∂v ∂w µ + + SMy ∂z ∂z ∂y
(10-12)
Dw −∂p ∂ ∂u ∂w ∂ ∂v ∂w = µ + + + + µ Dt ∂z ∂x ∂z ∂x ∂y ∂z ∂y +
∂ ∂w 2µ + λ div u + SMz ∂z ∂z
where div u =
∂u ∂v ∂w + + ∂x ∂y ∂z
(10-13)
(10-14)
TURBULENCE ON TIME-AVERAGED NAVIER-STOKES EQUATIONS Equations 10-1 through 10-14 only hold for laminar flow. At values of Reynolds number above NRecrit, a complicated situation emerges resulting in a radical change of flow character. In this case, fluid motion becomes intrinsically unsteady even with constant imposed boundary conditions. The velocity and all other flow properties vary in a random and chaotic manner. This regime is known as the turbulent flow. The instantaneous fluid velocity at a certain point is represented by its average value and a superimposed fluctuation. Taking Cartesian coordinates so that the velocity vector, u, has x-component u, y-component v, and z-component w: div u = 0
(10-15)
−1 ∂p ∂u + v div grad u + div( uu) = ρ ∂x ∂t
(10-16)
∂v −1 ∂p + div( vu) = + v div grad v ∂t ρ ∂y
(10-17)
Application of Computational Fluid Dynamics
∂w −1 ∂p + div(wu) = + v div grad w ∂t ρ ∂z
793
(10-18)
where u = U + u ′( t )
(10-19)
v = V + v ′( t )
(10-20)
z = W + w ′( t )
(10-21)
The resulting momentum balance for the mean velocity components U, V, and W becomes: ∂U −1 ∂P + div( UU ) = + v div grad U ρ ∂x ∂t ∂u ′ 2 ∂u ′v ′ ∂u ′w ′ + − − − ∂y ∂z ∂x
(10-22)
∂V −1 ∂P + div(VU ) = + v div grad V ρ ∂y ∂t ∂u ′v ′ ∂v ′ 2 ∂v ′w ′ + − − − ∂y ∂z ∂x
(10-23)
∂W −1 ∂P + div( WU ) = + v div grad W ρ ∂z ∂t ∂u ′w ′ ∂v ′w ′ ∂w ′ 2 + − − − ∂y ∂z ∂x
(10-24)
The extra stress terms result from six additional stresses, three normal stresses, and three shear stresses:
794
Modeling of Chemical Kinetics and Reactor Design
τ xx = −ρu ′ 2
τ yy = −ρv ′ 2
τ zz = −ρw ′ 2
τ xy = τ yx = −ρu ′v ′ τ xz = τ zx = −ρu ′w ′ τ yz = τ zy = −ρv ′w ′
(10-25)
These extra turbulent stresses are termed the Reynolds stresses. In turbulent flows, the normal stresses –ρu ′ 2 , – ρv ′ 2 , and – ρw ′ 2 are always non-zero because they contain squared velocity fluctuations. The shear stresses – ρu ′v ′ , – ρu ′w ′ , – ρv ′w ′ and are associated with correlations between different velocity components. If, for instance, u′ and v′ were statistically independent fluctuations, the time average of their product u ′v ′ would be zero. However, the turbulent stresses are also non-zero and are usually large compared to the viscous stresses in a turbulent flow. Equations 10-22 to 10-24 are known as the Reynolds equations. For a turbulence model to be useful in a general-purpose CFD code, it must be simple, accurate, economical to run, and have a wide range of applicability. Table 10-1 gives the most common turbulence models. The classical models use the Reynolds equations and form the basis of turbulence calculations in currently available commercial CFD codes. Large eddy simulations are turbulence models where the timedependent flow equations are solved for the mean flow and the largest eddies and where the effects of the smallest eddies are modeled.
TIME-DEPENDENT TURBULENT MIXING AND CHEMICAL REACTION IN STIRRED TANKS1 Blend time and chemical product distribution in turbulent agitated vessels can be predicted with the aid of Computational Fluid Mixing 1
Written by A. Bakker and J. B. Fasano. Presented at the AIChE Annual Meeting, November 1993, St. Louis, Paper No. 70C.
Table 10-1 Turbulence models Classical models
Large eddy simulation
Based on (time-averaged) Reynolds equations. 1. Zero equation model—mixing length model. 2. Two-equation model k-e model. 3. Reynolds stress equation model. 4. Algebraic stress model. Based on space-filtered equations.
Application of Computational Fluid Dynamics
795
(CFM) models. The blend time predictions show good agreement with the experimental correlation discussed below. Calculations for turbulent, time-dependent mixing of two chemicals exhibiting a competitive pair of reactions, are compared with the experimental results. The effects of the position of the inlet feed stream in the turbulent flow field are also studied below, which will show that process problems with turbulent chemical reactors can be avoided by incorporating the results of CFM simulations in the design stage. Blending of chemical reactants is a common operation in the chemical process industries. Blend time predictions are usually based on empirical correlations. When a competitive side reaction is present, the final product distribution is often unknown until the reactor is built. The effects of the position of the feed stream on the reaction byproducts are usually unknown. Also, the scale-up of chemical reactors is not straightforward. Thus, there is a need for comprehensive, physical models that can be used to predict important information like blend time and reaction product distribution, especially as they relate to scale and feed position. The objective of the following model is to investigate the extent to which Computational Fluid Mixing (CFM) models can be used as a tool in the design of industrial reactors. The commercially available program, FluentTM, is used to calculate the flow pattern and the transport and reaction of chemical species in stirred tanks. The blend time predictions are compared with a literature correlation for blend time. The product distribution for a pair of competing chemical reactions is compared with experimental data from the literature. MODEL The flow pattern is calculated from conservation equations for mass and mometum, in combination with the Algebraic Stress Model (ASM) for the turbulent Reynolds stresses, using the Fluent V3.03 solver. These equations can be found in numerous textbooks and will not be reiterated here. Once the flow pattern is known, the mixing and transport of chemical species can be calculated from the following model equation: ∂ ∂ ∂ µ t ∂X i ρX i ) + ρu i X i ) = ( ( + Ri ∂t ∂x i ∂x i Sc t ∂x i
(10-26)
796
Modeling of Chemical Kinetics and Reactor Design
Here, Xi is the mass fraction of chemical species i, and Ri is the rate of creation or depletion by chemical reaction. For a single-step, first order reaction, such as A + B → R, the reaction rate is given by: R i ∝ (C A C B + C A CB )
(10-27)
Here, CA and CB (upper case) denote the mean molar concentrations of reactants A and B while CA and CB (lower case) denote the local concentration fluctuations that result from turbulence. When the species are perfectly mixed, the second term on the right side containing the correlation of the concentration fluctuations, will approach zero. Otherwise, if the species are not perfectly mixed, this term will be negative and will reduce the reaction rate. Estimating this correlation term is not straightforward and numerous models are available. An excellent discussion on this subject was given by Hannon [1]. The model used here is a slightly modified version of the standard Fluent model [2]. Two possible reaction rates are calculated, the kinetic reaction rate Rki and a second reaction rate Rmi that is controlled by the turbulent mixing. The kinetic reaction rate for species i is calculated as:
R ki = KM i
∏
j reactants
ρX j Mj
(10-28)
The turbulent mixing limited reaction rate for species i is calculated as:
ρ X ε j R mi = M i A mn • minimum υ j M j k reactants j
(10-29)
The “minimum” function gives the minimum value of (ρXj/υjMj) for all the reactants j taking part in this reaction. Finally, the reaction rate Ri is calculated as the product of the molar stoichiometry υi of species i and the minimum of Rki and Rmi: Ri = –υi minimum (Rmi, Rki)
(10-30)
Application of Computational Fluid Dynamics
797
Here, Mi is the molecular weight of species i and Amn is an empirically determined model constant for reaction n. In this reaction system, υi is +1 for reactants and –1 for products. K is the kinetic rate constant of the reaction. The idea behind this model is that in regions with high turbulence levels the eddy lifetime k/ε will be short, the mixing fast, and as a result the reaction rate is not limited by small-scale mixing. On the other hand, in regions with low turbulence levels, small-scale mixing may be slow, which will limit the reaction rate. REACTION MODELING RESULTS The following competitive-consecutive reaction system was studied: K
(10-31)
K
(10-32)
A + B 1 → R 2 B + R →S
This is the reaction system used by Bourne et al. [3] and Middleton et al. [4]. The first reaction is much faster than the second reaction: K1 = 7,300 m3 • mole–1 • sec–1 versus K2 = 3.5 m3 • mole–1 • sec–1. The experimental data published by Middleton et al. [4] were used to determine the model constant Amn. Two reactors were studied, a 30-l reactor equipped with a D/T = 1/2 D-6 impeller and a 600-l reactor with a D/T = 1/3 D-6 impeller. A small volume of reactant B was instantaneously added just below the liquid surface in a tank otherwise containing reactant A. A and B were added on an equimolar basis. The transport, mixing, and reaction of the chemical species were then calculated based on the flow pattern in Figure 10-3. Experimental data were used as impeller boundary conditions. The product distribution XS is then calculated as: XS =
2C S C R + 2C S
(10-33)
In the reaction model used here it was assumed that small-scale mixing only affected the first reaction and that once this reaction had occurred, the species were locally well mixed. As a result, small-scale
798
Modeling of Chemical Kinetics and Reactor Design
Figure 10-3. Flow field in 30-l reactor (see full-color version on CD).
turbulent mixing did not affect the second reaction. This was achieved using different values of A mn for both reactions. For the second reaction, Am2 was set to infinity. The value for Am1 was then varied to study the effect on the predicted final product distribution. Figure 10-4 shows the predicted XS as a function of Am1 for the 30-1 reactor at 100 rpm. Decreasing Am1 slows the first reaction and increases the formation of the secondary product S. As a result, the predicted XS decreases with increasing Am1. It was found that Am2 = 0.08 gave the best predictions when compared to the experimental data from Middleton et al. [4] Figure 10-5 shows a comparison between the experimental data from Middleton et al. and the current model predictions for both the 30-l and 600-l reactors. XS is plotted as a function
Application of Computational Fluid Dynamics
799
Figure 10-4. Predicted XS versus Am1 for Am2 equals infinity. 30-l reactor at 100 rpm.
Figure 10-5. XS as a function of rpm. Model predictions compared with data from Middleton et al. [4].
800
Modeling of Chemical Kinetics and Reactor Design
of rpm. This graph shows that the model correctly predicts the effects of scale and impeller rotational speed, and is usually within 10% of the experimental results. The effect of the inlet position of the feed stream on the formation of the secondary byproducts S was studied. Figure 10-6 shows values of XS for various feed locations. XS varies only slightly when the inlet is located in the fluid bulk. However, when the feed is injected directly above the impeller, such that the feed stream immediately passes through the highly turbulent impeller zone, local mixing is much faster and does not limit the rate of the first reaction. As a result, there is less reaction byproduct S and the final XS in only 50% of what it would be if the feed were located away from the impeller. This qualitatively agrees with the experimental results of Tipnis et al. [5]. Although Tipnis et al. used a different set of reactions and different tank geometries, it was also found that injection near the impeller results in a lower XS than injection farther away from the impeller and that the relative differences are similar to those found in this study.
Figure 10-6. XS as a function of feed location. 600-l vessel at 100 rpm. Am1 = 0.08 and Am2 equals infinity.
Application of Computational Fluid Dynamics
801
Figure 10-7 shows the concentrations of R and S and the product distribution XS as a function of time for the feed location just above the impeller. The values are normalized with respect to the final values. R and S increase steadily with time. XS increases at first, reaching a local maximum just before the species are mixed by the impeller. The improved quality of the mixture favors the first reaction and XS decreases until it reaches a local minimum. At this point there is enough R present to allow the second reaction to occur even in relatively well mixed regions, and XS increases again until it asymptotically reaches a final value. Figures 10-8a through 10-8h show the local concentrations of species A, R, and S as a function of time for the 600-l tank at 100 rpm. BLEND TIME The mixing of two nonreacting species in a tank equipped with a high-efficiency impeller (Chemineer HE-3) was calculated using Fluent (text continued on page 806)
Figure 10-7. Concentrations of R and S and product distribution XS as a function of time, normalized with final values.
802
Modeling of Chemical Kinetics and Reactor Design
Figure 10-8a. The local mass fractions in the 2-D reaction simulation at Time = 0 s (see full-color version on CD).
Figure 10-8b. The local mass fractions in the 2-D reaction simulation at Time = 0.5 s (see full-color version on CD).
Application of Computational Fluid Dynamics
803
Figure 10-8c. The local mass fractions in the 2-D reaction simulation at Time = 1 s (see full-color version on CD).
Figure 10-8d. The local mass fractions in the 2-D reaction simulation at Time = 2 s (see full-color version on CD).
804
Modeling of Chemical Kinetics and Reactor Design
Figure 10-8e. The local mass fractions in the 2-D reaction simulation at Time = 3 s (see full-color version on CD).
Figure 10-8f. The local mass fractions in the 2-D reaction simulation at Time = 4 s (see full-color version on CD).
Application of Computational Fluid Dynamics
805
Figure 10-8g. The local mass fractions in the 2-D reaction simulation at Time = 10 s (see full-color version on CD).
Figure 10-8h. The local mass fractions in the 2-D reaction simulation at Time = 20 s (see full-color version on CD).
806
Modeling of Chemical Kinetics and Reactor Design
(text continued from page 801)
V3.03. The tank diameter was T = 1 m. Furthermore, Z/T = 1, D/T = 0.33, C/T = 0.32, and rpm = 58. The flow pattern in this tank is shown in Figure 10-9. Experimental data were used as impeller boundary conditions. Figure 10-10 shows the uniformity of the mixture as a function of time. The model predictions are compared with the results of the experimental blend time correlation of Fasano and Penny [6]. This graph shows that for uniformity above 90% there is excellent agreement between the model predictions and the experimental correlation. Figure 10-11a shows the concentration field at t = 0 sec. Figures 10-11b through 10-11d show the concentration field at t = 0,
Figure 10-9. Flow pattern in tank with HE-3 impeller.
Application of Computational Fluid Dynamics
807
Figure 10-10. Uniformity as a function of time.
4, 10, and 20 sec, respectively. After 80 sec the species are homogeneously mixed. DISCUSSION The models presented correctly predict blend time and reaction product distribution. The reaction model correctly predicts the effects of scale, impeller speed, and feed location. This shows that such models can provide valuable tools for designing chemical reactors. Process problems may be avoided by using CFM early in the design stage. When designing an industrial chemical reactor it is recommended that the values of the model constants are determined on a laboratory scale. The reaction model constants can then be used to optimize the product conversion on the production scale varying agitator speed and feed position. However, the range of validation of the reaction model was limited. Only one impeller type and one reaction system were studied. In the future, the model should be tested for a wider range of geometries and reaction systems and, if necessary, modified to increase its validity. (text continued on page 810)
808
Modeling of Chemical Kinetics and Reactor Design
Figure 10-11a. The concentration field in the 3-D blending simulation at Time = 0 s (see full-color version on CD).
Figure 10-11b. The concentration field in the 3-D blending simulation at Time = 4 s (see full-color version on CD).
Application of Computational Fluid Dynamics
809
Figure 10-11c. The concentration field in the 3-D blending simulation at Time = 10 s (see full-color version on CD).
Figure 10-11d. The concentration field in the 3-D blending simulation at Time = 20 s (see full-color version on CD).
810
Modeling of Chemical Kinetics and Reactor Design
(text continued from page 807)
REFERENCES AND RECOMMENDED READING 1. Hannon, J., “Mixing and Chemical Reaction in Tubular Reactors and Stirred Tanks,” PhD. Thesis, Cranfield Institute of Technology, U.K., 1992. 2. Fluent V3.03 Users Manual, Fluent Inc., Lebanon, NH, 1990. 3. Bourne, J. R., Kozicki, F., and Rys, P., “Mixing and Fast Reaction Reaction –1; Test Reactions to Determine Segregation,” Chem. Eng. Sci., 36, (10), 1643, 1981. 4. Middleton, J. C., Pierce, F., and Lynch, P. M., “Computations of Flow Fields and Complex Reaction Yield in Turbulent Stirred Reactors and Comparison with Experimental Data,” Chem. Eng. Res. Des., Vol. 64, pp. 18–21, 1986. 5. Tipnis, S. K., Penny, W. R., and Fasano, J. B., An experimental investigation to determine a scale-up method for fast competitive parallel reactions in agitated vessels, AIChE Annual Meeting, St. Louis, November 1993. 6. Fasano, J. B. and Penny, W. R., “Avoid Blending Mix-ups,” Chem. Eng. Prog., pp. 56–63, October 1991. 7. Versteeg, H. K. and Malalasekera, W., An Introduction to Computational Fluid Dynamics—The Finite Volume Method, Addison Wesley Longman Ltd., 1995.
NOMENCLATURE Amn Ci k K Mi Ri Rki Sct t ui Xi XS ε µt
= = = = = = = = = = = = = =
Model constant for reaction n Concentration of species i (mole m–3) Turbulent kinetic energy density (m2s–2) Reaction rate constant (m3 mole–1 s–1) Molecular weight of species i Production/depletion of species i (kg m–3 s–1) Kinetic reaction rate of species i (kg m–3 s–1) Turbulent Schmidt number Time (sec) Velocity in directions i (m s–1) Spatial coordinate in direction i (m) Product distribution Turbulent kinetic energy dissipation rate density (m2 s–3) Turbulent viscosity (kg m–1 sec–1)
Application of Computational Fluid Dynamics
811
ρ = Liquid density, (kg m–3) υi = Stoichiometry species i
IMPROVE REACTORS VIA COMPUTATIONAL FLUID DYNAMICS2 INTRODUCTION Flow modeling is an excellent tool for enhancing the performance of any process vessel. Applying such a technique to reactors can be especially fruitful, because of reactors’ central role in chemical processes. In most reactor-design situations, the reactions and the catalysis system are set beforehand. For any given combination of them, reactor performance becomes a complex function of the underlying transport processes. These in turn are governed by the fluid dynamics of the reactor. Detailed flow analysis and modeling can, accordingly lead to numerous performance improvements. For instance, an engineer can raise the throughput of a fixed-bed reactor by identifying and getting rid of any fluid maldistribution in the vessel. Modifying the feed-pipe locations in a semi-batch reactor can improve its selectivity. As another example, the capacity of an oxidation reactor might be raised by allowing oxygen-enriched instead of ordinary air to be used without risking safety. The basic strategy for realizing such performance enhancements is summarized in Table 10-2. The principles can be applied to improving
Table 10-2 Strategy for performance enhancement—A summary Analyze the existing reactor or design • • • •
2
Flow regimes, operability Residence time distribution Mixing Transport processes
Develop alternative versions
Evaluate and test the new alternatives • Screening • Optimization • Validation
Written by Vivek V. Ranade and reprinted by special permission from Chemical Engineering, May; Copyright © 1997 by Chemical Week Association, New York, NY, 10106.
812
Modeling of Chemical Kinetics and Reactor Design
the performance of an existing reactor, or to optimizing a reactor that has not yet been specified or built. FLOW MODELING CHOICES The engineer is offered a large variety of flow-modeling methods, whose complexity ranges from simple order-of-magnitude analysis to direct numerical simulation. Up to now, the methods of choice have ordinarily been experimental and semi-theoretical, such as cold flow simulations and tracer studies. Despite their popularity, these methods normally have an inherent limitation—the fluid dynamics information they generate is usually described in global parametric form. Such information conceals local turbulence and mixing behavior that can significantly affect vessel performance. And because the parameters of these models are necessarily obtained and fine-tuned from a given set of experimental data, the validity of the models tends to extend over only the range studied in that experimental program. Computational fluid dynamics (CFD), which solves fluid-dynamics problems with the aid of a digital computer, avoids these drawbacks while offering other advantages as well.3 With CFD, the engineer can build a flow model having global and local information alike, simulating the flow and turbulence characteristics of reactors or other process equipment in detail. And for systems at high temperatures or pressures, or having high corrosivity or a high degree of hazard, CFD models may well be the only good tools available for studying the fluid dynamics. CFD requires relatively few restrictive assumptions, and gives a complete description of the flow field. Complex configurations can be treated. When applied to a reactor that is operating, CFD’s diagnostic probing via computer simulation does not disturb the operation. Various alternative configurations can be screened quickly using the validated CFD model. Applying CFD to reactors or other equipment [1,2] entails a number of tasks or activities: • Formulating the relevant transport equations. • Establishing the necessary constitutive and closure equations (the former relate fluid stresses with velocity gradients; the latter relate unknown Navier-Stokes-equation correlations with known quantities). 3
Chemical Engineering, December 1996, pp. 66–72.
Application of Computational Fluid Dynamics
813
• Formulating appropriate boundary conditions. • Selecting the most suitable numerical techniques to solve the equations. • Choosing or developing a suitable computer program (also referred to as a code) to implement the numerical techniques. • Validating these techniques and programs. • Developing effective flow-simulation strategies for the equipment. We illustrate these tasks and activities by applying them to one particular reactor. First, however, we set the stage by summarizing how the steps are carried out for a reactor of any type.4 APPLYING CFD The first step is to define the objectives of the flow model, and to identify those flow aspects that are relevant for the performance of the reactor. Then, the engineer must identify and quantify the various times and space scales involved, as well as the geometry of the system. These actions allow the problem to be represented by a mathematical model. Creating this model accurately is the most crucial task in the flow modeling project. The next step is to map the model onto a CFD computer program. This mainly requires specifying the geometry of the equipment, generating appropriate spatial grids (meshes) and boundary conditions, and setting the required terms in the transport equations included in the program. Sometimes, it is also necessary to generate sub-models, providing such information as physical properties, reaction rates, interphase drag coefficients, or heat or mass-transfer parameters. Prior knowledge or educated guesses about the various time and space scales and the likely regions of steep gradients help in generating a suitable grid. Complex geometries can be handled by using coordinate systems that are neither rectangular nor polar, but instead are fitted to the shape of the vessel at hand. While generating the grids, extremes of aspect ratio and skewness are avoided. It is not too important that the grids intersect at right angles, so long as the actual angles are greater than 45º. Once the appropriate grid is generated,
4 Although this article focuses on design of reactors, keep in mind that the principles presented here can also be applied to other equipment through which process streams pass.
814
Modeling of Chemical Kinetics and Reactor Design
the user specifies the relevant properties of the process fluids. Typically, these include viscosity, density and thermal conductivity. Then, the model’s boundary conditions on the edges and external surfaces of the vessel are specified, taking care to understand and then allow for the influence of the location of outflow and inflow boundaries on the predicted flow results. Wall functions (empirical functions that estimate the effects of walls on flow) can provide boundary conditions near the wall for turbulent flows, a practice that avoids the need for fine grids near the walls. However, this technique is used only with caution when heat or mass transport from the wall is important. Once the problem has been mapped onto the CFD program, the engineer assesses the sensitivity of the predicted results to the chosen grid spacing, time steps, boundary conditions and other parameters of the model. Making some preliminary simulations can help provide such understanding. Because so many parameters affect the performance of the CFD program and the predicted results, we recommend that the simulations for this step be planned systematically. Such a plan must vary according to the problem at hand and the available information. However, some general comments can still be made. For instance, grid sequencing is often useful. In this strategy, iterative model results are first obtained, rapidly, using a small number of grids (i.e., a coarse mesh). These results can then be used as initial guesses for iterations yielding more-precise answers from finer meshes. Similarly, it is often desirable to increase the complexity of the problem in steps, after starting with a highly simplified version. Overall convergence rates of CFD models can be controlled to some extent by suitably adjusting under relaxation parameters (parameters that damp the iterative solution of algebraic equations; for suggestions in this regard see reference 3). Furthermore, monitoring the rate of convergence for each equation can also give guidelines on how to enhance the overall convergence rate of the CFD program. Before putting the model to work, a final step remains: Validation exercises must verify that the model has indeed captured the important flow characteristics for the task at hand. A SPECIFIC REACTOR The foregoing summary can be understood better by seeing how the procedure is applied to a particular case, namely a radial-flow, fixedbed reactor. Such reactors appear in a variety of processes, including
Application of Computational Fluid Dynamics
815
the catalytic synthesis of ammonia, catalytic reforming of petroleum stocks, xylene isomerization, and various desulfurizations. They handle large gas flowrates with minimum pressure drop, and are especially suitable for processes in which fluids must be contacted with solid particles at high space velocity [4]. The fluid dynamics of radial flow reactors (RFRs) in general is complex, and involves severe changes in the flow direction. In RFRs, feed enters parallel to the reactor axis, either through a center pipe or an annulus, and then flows radially inward through the annular catalyst basket. Perfect radial flow always results in the highest conversion [4]. Any axial component of the flow decreases the conversion, because it mixes fluids of different “ages” within the bed (an effect similar to backmixing in tubular reactors). Therefore, flow maldistribution is the most important performance determinant in a radial flow fixed bed reactor. Flow modeling can be used to screen various design solutions, so as to minimize the maldistribution. DEFINE THE PROBLEM One half of a typical radial-flow, fixed-bed reactor is shown in Figure 10-12a. The reactor configuration is axis-symmetric. The annular catalyst bed is supported by cylindrical inner and outer screens and by top and bottom cover plates, the latter actually being also in the form of a screen. Reactants enter at the top. As the reader can visualize, the flow changes direction several times after hitting the cover plate. The reactants enter the catalyst bed from the annular space between the bed and reactor shell, passing through the outer support screen. The product stream goes out through the outlet located at the bottom of the central pipe. Because the cover plate also acts as a shroud, the active catalyst bed is limited to the annular Zone A as shown in the inset in Figure 10-12a. The extent of flow maldistribution within the active bed depends mainly on the throughput, the configuration details around and within the bed, and the flow resistance offered by the support screens and the bed. It may be possible to control the bed resistance to some extent by appropriately selecting the pellet size. However, the design of support screens and the configuration are the most important parameters governing the fluid dynamics and therefore the performance. For this reactor, our capacity-enhancement attempt in this example consists mainly of two strategies:
816
Modeling of Chemical Kinetics and Reactor Design
Figure 10-12a. The configuration of this radial fixed-flow reactor provides scope for investigating proposed performance-enhancing modifications.
Application of Computational Fluid Dynamics
817
• Assessing the fluid dynamics of the initial RFR configuration, and identifying the scope of eliminating the flow maldistribution, if any. • Exploring the possibility of loading more catalyst, by increasing the volume of active catalyst bed. This might be achieved by eliminating the shroud and filling the catalyst up to the top cover plate (thus picking up the space shown as Zone B of Figure 10-12a, inset) and also by filling the catalyst till the bottom of the reactor (Zone C in Figure 10-12a). However, it is important to ensure, by proper screen redesign, that such shroud elimination would not lead to flow maldistribution. Also, the support screens for the catalyst filled into Zone C would need to be redesigned so as to ensure the uniform flow through the catalyst bed. It is therefore essential to develop a detailed flow model to carry out our two strategies. DEVELOP THE FLOW MODEL The typical rate of flow (throughput) in RFRs such as the one under consideration is such that the flow is turbulent (feed velocity at the inlet is 40 m/s). Therefore, it is necessary to select an appropriate turbulence model—in particular, we need to simulate the flow in the upper region of the reactor correctly, so that the influences of the aforementioned severe changes in the flow directions can be predicted accurately. Expecting that the recirculating flow in the upper region of the reactor will show spatial variation in velocity and length scales of turbulence, we need at least a two-equation turbulence model. We select a standard model, known as the k-ε5, that has proved versatile. The next step is to characterize the resistances offered by the porous catalyst bed and support screens. Several correlations relating the pressure drop through porous beds and velocity and bed characteristics are available. We select an Ergun equation6 to represent the resistance of catalyst bed: 2 ρ (1 − ε ) 2 ∆P µ (1 − ε ) = 150 V (10-33) V + 1.75 2 3 L D P Φ P ε D P Φ P ε 3
5
For more insight into this model, see “CFD Comes of Age in CPI,” Chemical Engineering, December 1996, pp. 68–72.
6 See, for instance, Darby, Chemical Engineering Fluid-Mechanics, Marcel Dekker, New York, 1996, pp. 68–72.
818
Modeling of Chemical Kinetics and Reactor Design
where ∆P/L µ DP ΦP ρ V
= = = = = =
the pressure drop per unit length viscosity equivalent pellet diameter sphericity density superficial velocity
Our knowledge of the pellet size and shape and the bed voidage are thus sufficient to characterize the bed resistance. For the particular case investigated here, the resistance can be represented as: ∆P µ 1 = V + C 2 ρ V 2 α L 2
(10-34)
with permeability α as 10–8 m2 and inertial resistance coefficient C2 as 104/m. The resistance of the screens can be represented in terms of contraction and expansion losses. The velocity heads lost during flow through the screens can also be expressed in the form similar to that described in Equation 10-34 by setting α equal to very high value (1010) with an appropriated value for C2. The compressibility of the gaseous feed can be ignored because the pressure drops are low. The physical properties of the feed (viscosity as 10–5 Pa-s and density as 1 kg/m3) can thus be assumed constant. Since we need not simulate any reactions or heat transfer in this exercise, we do not need to develop sub-models. MAP THE MODEL INTO A PROGRAM We choose to map the model developed in the preceding section onto a particular CFD software program, Fluent Version 4.317. The reactor geometry is likewise modeled and, an appropriate grid for the problem is generated by using preBFC7 software. In light of the reactor configuration, we select a geometry that is axis-symmetric and twodimensional. Preliminary numerical experiments show us that so long as the number of grids in the radial direction is over 40 and the number in the axial direction over 100, the predicted results of the pressure drop and flow maldistribution become insensitive to the actual number of grids. 7
Of Fluent Inc., Lebanon, NH.
Application of Computational Fluid Dynamics
819
The mesh used for all the subsequent computations (50 grids in the radial direction and 116 in the axial direction) appears in Figure 10-12b. The standard k-ε model simulates the turbulence in the reactor. For flow within the porous catalyst bed, however, we suppress the turbulence. We enter the appropriate physical properties of the system, and employ standard boundary conditions at the impermeable walls and the reactor outlet. To represent the turbulence of the feed stream at the inlet, we treat it as pipe-flow turbulence. These model equations can then be solved; for instance, via the well-known Simple algorithm [3]. To facilitate fast convergence, it is useful to make a reasonable initial guess of the pressure drop across the catalyst bed. We choose to carry out only few numerical experiments to select the solution parameters. Detailed optimization of the solution parameters is difficult and often expensive computationally, so we do not recommend it. Finally, we must validate the model. Though detailed experimental data for the velocity and pressure profiles are not available for this particular RFR, we can employ the data on the overall pressure drop across the bed to validate the model to some extent. We find that the predicted overall pressure drop across the bed (10 kPa) shows good agreement with the available data. PUT THE MODEL TO WORK Now the model is ready for optimizing the reactor design. Of particular interest in this example are details on the flow at the locations where the flow direction changes abruptly, and the extent of maldistribution within the active catalyst bed. First we run the model so as to study the influence of screen resistance on the overall flow patterns and on the maldistribution. The resulting profiles of inward radial velocity at the inner screen across the catalyst bed appear in Figure 10-13 for different screen resistances. It can be seen that higher screen resistance leads to more-uniform flow, as one would expect. The existing screens (with resistance coefficients C 2 of 2 × 10 5 /m) appear to be satisfactory, since the deviations experienced are less than 10%. From the contours of the stream function and a closeup of the flow field near the shroud and top cover plate, we note that the shroud causes significant recirculation at the top end of the catalyst bed. Also, the downward velocity field in the annular region between catalyst bed and reactor shell is found not to be uniform. The comparative
820
Modeling of Chemical Kinetics and Reactor Design
Figure 10-12b. When CFD is the investigator’s tool, a grid or mesh is mathematically superimposed over the vessel.
Application of Computational Fluid Dynamics
821
Figure 10-13. The radial velocity at the inner screen of the reactor does not vary much with screen resistance.
uniformity (Figure 10-13) of the flow coming out of the catalyst bed into the central pipe signals to us that we cannot enhance the capacity of the reactor much by modifying the existing screen designs. So we turn to the second possibility, namely removing the shroud and increasing the active catalyst loading by filling the catalyst in Zones B and C as shown in Figure 10-12a. We simulate such a scenario, specifying support screens for Zones B and C that are similar to the existing ones in Zone A. Then we reexamine the contours of the stream function and the details of flow near the top cover plate. It turns out that the simulated removal of shroud gives more circulation in the upper region of the RFR (Figure 10-14). The predicted profile of the radial velocity at the inner edge of the catalyst bed appears in profile B in Figure 10-15 (the corresponding profile for the earlier case is also shown for comparison
822
Modeling of Chemical Kinetics and Reactor Design
Figure 10-14. Images generated during CFD help assess the desirability of proposed vessel-design modifications.
Application of Computational Fluid Dynamics
823
Figure 10-15. The lines show radial velocity at the inner reactor screen for different modification proposals.
purposes as profile A). Profile B confirms that the removal of shroud and filling the catalyst in Zones B and C would make the flow through the catalyst bed much less uniform. The high resistance offered by the support screens of Zone C leads to very low flow through that zone, and also leads to a recirculating zone in the annular space between the catalyst bed and the reactor shell. The non-uniform flow through the catalyst bed also brings about significant recirculation in the central pipe. In short, the model tells us that the mere removal of shroud and filling the catalyst in Zones B and C may not lead to capacity enhancements, due to the associated problems of maldistribution.
824
Modeling of Chemical Kinetics and Reactor Design
On the other hand, the model may be able to bring out a way to redesign the support screens to improve the flow uniformity. Specifically, we postulate that the shroud might be replaceable by a support screen with (due to its shroudlike role) significantly higher resistance than the existing support screens. To examine this possibility, we adapt the model so as to contain an outer support screen resistance for Zone B five times that for Zone A. Meanwhile, to get more flow through Zone C, the support screen resistance at that area might be reduced. We simulate this possibility by specifying zero resistance for the cover plate (which, as previously noted, is actually a screen) for Zone C. The resistance of the inner support screen for Zone C is set to 5 × 104/m. The resulting contours of the stream lines, a close-up of a vector plot near the top cover plate and the profile of radial velocity at the inner edge of the catalyst bed (Profile C, Figure 10-15) all show us that these last-named proposed changes would have many benefits. The main ones are: • Recirculation in the annular space between the catalyst bed and reactor shell is eliminated. • The size of the recirculating zone in the central pipe is much reduced. • Flow non-uniformity due to shroud removal is largely eliminated. • Flow through Zone C also has been considerably increased, and is now of the same order as that through Zones A and B. In summary, our CFD analysis has let us simulate a variety of changes in the design of a particular RFR. Some of the changes, such as just removing the shroud, prove to offer little or no benefit. Others, notably the support-screen redesign, seem well worth pursuing. KEEP IN MIND It must be reemphasized that the value of a flow model’s recommendations depends on how well the model represents the real process situation. The reactor and the process streams must be described accurately, as must the relationship between the fluid dynamics and the process performance. Often, process engineers are tempted to rely on commercial CFD programs for the fluid dynamics equations. However, any commercial program may have particular limitations for simulating complex process equipment. On the other hand, almost all
Application of Computational Fluid Dynamics
825
of such programs let the user make adaptations that accommodate the situation at hand. Turbulence, which prevails in the great majority of fluid-flow situations, poses special problems. Due to the wide range of space and time scales in turbulence flow, its exact numerical simulation is possible only at relatively low Reynolds number (around 100 or below) and if the geometry is simple. For most applications, the engineer must instead resort to turbulence models along with time-averaged Navier-Stokes equations. Unfortunately, most available turbulence models obscure physical phenomena that are present, such as eddies and high-vorticity regions. In some cases, this deficiency may partially offset the inherent attractiveness of CFD noted earlier. Concluding, it is essential to represent complex, real-life flow situations by computationally tractable models that retain adequate details. As an example, a computational “snapshot” approach that simulates the flow in stirred reactors or other vessels for any arbitrary impeller has been developed [5]. This approach lets the engineer simulate the detailed fluid dynamics around the impeller blades with much less computations that would otherwise be required. Improvements in CFD technique are likely to encourage further work along these lines. Application of CFD to reactors and other process vessels is sure to grow. It not only permits innovation and performance enhancement for new processes and equipment, but also allows substantial improvement in the operation of mature technologies. USES OF CFD CODES Almost all modern CFD codes have a k – ε model. Advanced models like algebraic stress models or Reynolds stress model are provided FLUENT, PHOENICS and FLOW3D. Table 10-3 summarizes the capabilities of some widely used commercial CFD codes. Other commercially CFD codes can be readily assessed on the web from hptt//www.cfd-online.com This is largest CFD site on the net that provides various facilities such as a comprehensive link section and discussion forum. (text continued on page 828)
Eddy viscosity k-l, k-ε, and Reynolds stress.
Available (including Available supersonic) Choice of models available, user subroutines.
Turbulence modeling capability (range of models).
Compressible flow capability
Non-Newtonian modeling capability Power law, and difficult to implement user subroutines.
k-ε and Algebraic stress, Reynolds stress and renormalization group theory (RNG) V. 4.2
Finite volume
Finite volume
Numerical Method
Fluent Europe, Sheffield, U.K. or Lebanon, NH
Cham, London, U.K. or Hunstville, AL or Creare.x. Inc. Hanover, NH
FLUENT
Supplier
PHOENICS
Choice of models available.
Available (including supersonic)
ASTEC
Finite volume
CFDS, AEA Tech., Oxon, U.K. or Pittsburgh, PA
Not available.
Weakly compressible, Mach. No. up to 0.2
k-ε, low Reynolds k-ε No., Algebraic stress, Reynolds stress and Reynolds flux.
Finite volume
CFDS AEA Tech., Oxon, U.K. or Pittsburgh, PA
FLOW3D
Table 10-3 Particular features of some commercial CFD codes—A comparison
Power law, Bingham, Generalized power law, and user subroutines.
Not available
Mixing length (user subroutine) and k-ε.
Finite Element
Fluid Dynamics, International, Inc. Evanston, IL, USA
FIDAP
826 Modeling of Chemical Kinetics and Reactor Design
Combustion/ chemical reaction. General purpose
User supplied FORTRAN subroutines can be added.
Combustion modeling capability.
Target Application
Code expandability. User supplied FORTRAN subroutines can be added.
General purpose.
Combustion/ chemical reaction
Structured mesh multiblock.
Limited.
Available.
Source: Dombrowski, N., et al., “Know the CFD Codes,” Chem. Eng. Prog., September 1993.
Cannot add FORTRAN subroutines directly. Need full source code for code expansion.
General purpose.
Combustion/ chemical reaction
Structured mesh.
Structured mesh, interactive mesh generation.
Mesh generation features.
Available. Not available.
Available.
Free surface capability. Available.
Multiphase flow capability.
User supplied FORTRAN subroutines can be added.
Main area of application is in heat and fluid in highly complex geometries.
Combustion/ chemical reaction
Unstructured mesh, multiblock interface to PATRAN and IDEAS.
Available.
Available.
User supplied FORTRAN subroutines can be added.
General purpose.
Simple combustion/ Chemical reaction
Unstructured.
Available.
Available.
Application of Computational Fluid Dynamics 827
828
Modeling of Chemical Kinetics and Reactor Design
(text continued from page 825)
REFERENCES 1. Ranade, V. V., “Computational fluid dynamics for reactor engineering,” Reviews in Chem. Eng., 11, 229, 1995. 2. Shyy, W., Application of body-fitted coordinates in transport processes, in “Advances in Transport Processes,” Mujumdar, A. S. and Mashelkar, R. A., Eds., Vol. 9, Elsevier, Amsterdam, 1993. 3. Patankar, S. V., Numerical Heat Transfer and Fluid Flow, Hemisphere, Washington, D.C., 1980. 4. Chang, H.-C. and Calo, J. M., An analysis of a radial-flow packedbed reactors: how are they different?, in “Chemical Reactors,” H. S., Fogler, Ed., ACS Symposium series 168, ACS, Washington, D.C., 1981. 5. Ranade, V. V. and Dometti, S. M. S., “Computational snapshot of flow generated by axial impellers in baffled stirred vessels,” Chem. Eng. Res. Des., 74A, 476–484, 1996. Suggested Literature Computational Fluid Dynamics: 1. Spalding, D. B., Imperial College Report HTS/80/1, 1980. 2. Anderson, D.A., et al., Computational fluid mechanics and heat transfer, Hemisphere, New York, 1984. 3. Nullaswamy, M., “Turbulence models and their applications to the predictions of internal flows,” Computers and Fluids, 15, 151, 1987. 4. Oran, E. S. and Boris, J. P., Numerical Simulation of Reactive Flows, Elsevier, New York, 1987. 5. Hutchings, B. and Iannuzzelli, R., “Taking the measure of fluid dynamics software,” Mech. Eng., 72, May 1987. 6. Dombrowski, N., et al., “Know the CFD Codes,” Chem. Eng. Prog, September 1993. Stirred-Vessels Reactors: 7. Ranade, V. V., Interaction of macro-micromixing in agitated reactors, in “Advances in Transport Processes,” Mujumdar, A. S. and Mashelkar, R. A., Eds., Vol. 9, Elsevier, Amsterdam, 1993. 8. Bakker, A., et al., “Pinpoint mixing problems with lasers and simulation software,” Chem. Eng., January 1994.
Application of Computational Fluid Dynamics
829
9. Ranade, V. V. and van den Akker, H.E.A., “Modeling of flow in gas-liquid stirred vessels,” Chem. Eng. Sci., 49, 5175, 1994. Bubble-Column Reactors: 10. Svendsen, H. F., et al., “Local flow structures in internal-loop and bubble column reactors,” Chem. Eng. Sci., 47, 3297, 1992. 11. Ranade, V. V., “Computational fluid dynamics for reactor engineering,” Reviews in Chem. Eng., 11, 229, 1995. Fixed-Bed Reactors: 12. Foumeny, E. A. and Benyahia, F., “Can CFD improve the handling of air, gas and gas-liquid mixtures?’ Chem. Eng. Prog., February 1993. 13. Ranade, V. V., “Modeling of flow maldistribution in a fixed bed reactor using phoenics,” J. of Phonics, 7, 3, 1994. Fluidized-Bed Reactors: 14. Ding, J. and Gidaspaw, D., “Bubbling fluidization model using kinetic theory of granular flows,” AIChE J, 36, 523, 1990. 15. Gidaspaw, D. and Therdtianwong, A., Proceedings of International Conference on Circulating Fluidized Beds, 436, 1993. 16. Patel, M. K., et al., “Numerical modelling of circulating fluidized beds,” Comp. Fluid Dyn., 1, 161, 1993. Flow Metering and Process Piping: 17. Patel, B. R. and Sheikoholeslami, Z., Numerical modelling of turbulent flow through the orifice meter, International Symposium on Fluid Flow Measurement, Washington, D.C., November 1986. 18. Ranade, V. V. and Kumaran, G., Computational fluid dynamics for piping engineering in “Proceeding of First National Seminar on Piping Engineering,” MIT, June 1995. 19. Dometti, S. M. S. and Ranade, V. V., Simulation of vortex flow meters, National Workshop on Modelling in Hydraulic Engineering, CWPRS, June 1995.
830
Modeling of Chemical Kinetics and Reactor Design
CHAPTER ELEVEN
Biochemical Reaction INTRODUCTION The processing of biological materials and employing biological agents such as cells, enzymes, or antibodies are the principal domain of biochemical engineering. Biochemical reactions involve both cellular and enzymatic processes and the principal differences between the biochemical and chemical reactions lie in the nature of the living systems. Small living creatures known as microorganisms interact in many ways with human activities. Microorganisms play a primary role in the capture of energy from the sun. Additionally, their biological activities also complete critical segments of the cycles of carbon, oxygen, nitrogen, and other elements necessary for life. The cell is the unit of life, and cells in multi-cellular organism function together with other specialized cells. Generally, all cells possess basic common features. Every cell contains cytoplasm, a colloidal system of large biochemicals in a complex solution of smaller organic molecules and inorganic salts. The use of cells or enzymes taken from cells is restricted to conditions at which they operate, although most plant and animal cells live at moderate temperatures but cannot tolerate extremes of pH. In contrast, many microorganisms operate under mild conditions, some perform at high temperatures, others at low temperatures and also pH values, which exceed neutrality. Some can tolerate concentrations of chemicals that can be highly toxic in other cells. Thus, successful operation depends on acquiring the correct organisms or enzymes while preventing the entry of foreign organisms, which could impair the process. Some variables such as temperature, pH, nutrient medium, and redox potential are favorable to certain organisms while discouraging the growth of others. The major characteristics of microbial processes that contrast with those of ordinary chemical processing include the following [1]: 830
Biochemical Reaction
831
• The reaction medium is invariably aqueous. • The products are made in low concentrations (rarely more than 5%–10% for chemicals and much less for particular enzymes). • Reaction temperatures are low, usually in the range of 10–60°C. Also the optimum range in individual cases may be 5°C or less. • The processes require a mild and narrow range of pH. • Generally, the scale of commercial processes (i.e., with the exception of potable ethanol or glucose isomerate) is modest, and for enzymes it is very low, only a few kg/day. • The mass of microbes often increases simultaneously increases with the production of chemicals. • Batch reactors are often used, although there are few large-scale continuous processes. • The air is sterilized to prevent contamination during the process operation. The reactant is referred to as a substrate. Alternatively it may be a nutrient for the growth of cells or its main function may require being transformed into some desirable chemical. The cells select reactants that will be combined and molecules that may be decomposed by using enzymes. These are produced only by living organisms, and commercial enzymes are produced by bacteria. Enzymes operate under mild conditions of temperature and pH. A database of the various types of enzymes and functions can be assessed from the following web site: http://www.expasy.ch/enzyme/. This site also provides information about enzymatic reactions. This chapter solely reviews the kinetics of enzyme reactions, modeling, and simulation of biochemical reactions and scale-up of bioreactors. More comprehensive treatments of biochemical reactions, modeling, and simulation are provided by Bailey and Ollis [2], Bungay [3], Sinclair and Kristiansen [4], Volesky and Votruba [5], and Ingham et al. [6].
KINETICS OF ENZYME-CATALYZED REACTIONS ENZYME CATALYSIS All enzymes are proteins that catalyze many biochemical reactions. They are unbranched polymers of α-amino acids of the general formula
832
Modeling of Chemical Kinetics and Reactor Design
The carbon-nitrogen bond linking the carboxyl group of one residue and the α-amino group of the next is called a peptide bond. The basic structure of the enzyme is defined by the sequence of amino acids forming the polymer. There are cases where enzymes utilize prosthetic groups (coenzymes) to aid in their catalytic action. These groups may be complex organic molecules or ions and may be directly involved in the catalysis or alternately act by modifying the enzyme structure. The catalytic action is specific and may be affected by the presence of other substances both as inhibitors and as coenzymes. Most enzymes are named in terms of the reactions they catalyze (see Chapter 1). There are three major types of enzyme reactions, namely: 1. Soluble enzyme—insoluble substrate 2. Insoluble enzyme—soluble substrate 3. Soluble enzyme—soluble substrate The predominant activity in the study of enzymes has been in relation to biological reactions. This is because specific enzymes have both controlled and catalyzed synthetic and degradation reactions in all living cells. Many of these reactions are homogeneous in the liquid phase (i.e., type 3 reactions). Enzymes are grouped with respect to the type of reaction catalyzed. The largest groups of enzymes are hydrolytic and oxidative enzymes. The former, which catalyze the hydrolysis of esters, glycosidic linkages in polysaccharides, and the hydrolysis of peptide linkages are complex acid-base catalysts, which enhance the transfer of hydrogen ions. Oxidative enzymes are engaged in oxidation-reduction processes, and accelerate electron-transfer processes. There are groups transferring enzymes, which promote the interchange of groups, such as amino and keto groups between two molecules. Other groups of enzymes are lyases, which catalyze the addition of chemical groups to double bonds, and isomerases, which catalyze isomerization reactions. Examples of some common enzyme-catalyzed reactions are:
Biochemical Reaction
833
• Glucose oxidase, which catalyzes the oxidation of glucose to gluconic acid. E Glucose + O 2 + H 2 O → gluconic acid + H 2 O 2 where E denotes enzyme. • L-asparaginase, which catalyzes the hydrolysis of L-asparagine to L-aspartate. E L − Asparagine + H 2 → L − aspartate + NH 3 This is used in the treatment of some cancer cells, where Lasparaginase is used to remove an essential nutrient, thus inhibiting their growth. • Decomposition of hydrogen peroxide (H2O2) in aqueous solution with catalase. E 2 H 2 O 2 → 2H 2O + O2 The hydrogen peroxide produced in the glucose oxidase catalyzed reaction has an antibacterial action. If the presence of hydrogen peroxide is undesirable in the product, catalase is added to remove the peroxide. • Hydrolysis of urea with the enzyme (E) urase.
(NH 2 )2 CO + H 2O E→ CO2 + 2 NH3 • Hydrolysis of starch with amylase to form glucose
(C6 H10 O5 )n + nH 2O E→ nC6 H12O6 This is an essential step in the conversion of corn to full-grade ethanol. Kinetic studies involving enzymes can principally be classified into steady and transient state kinetics. In the former, the enzyme concentration is much lower than that of the substrate; in the latter much higher enzyme concentration is used to allow detection of reaction intermediates. In steady state kinetics, the high efficiency of enzymes as a catalyst implies that very low concentrations are adequate to enable reactions to proceed at measurable rates (i.e., reaction times of a few seconds or more). Typical enzyme concentrations are in the range of 10–8M to 10–10M, while substrate concentrations usually exceed 10–6M. Consequently, the concentrations of enzyme-substrate intermediates are low with respect to the total substrate (reactant) concentrations, even when the enzyme is fully saturated. The reaction is considered to be in a steady state after a very short induction period, which greatly simplifies the rate laws.
834
Modeling of Chemical Kinetics and Reactor Design
FACTORS AFFECTING ENZYME CATALYZED REACTIONS Enzymes possess high specificity and efficiency as catalysts. However, their rates of reactions can be influenced by certain factors, which include the following: • • • • • • •
The concentrations of enzyme and substrate The nature of the substrate The nature of the enzyme (E) The presence of inhibitors and coenzymes Temperature pH External factors (e.g., irradiation) and shear
Some of the main experimental results involving concentration effects are: 1. The rate of reaction (–rs) or (rp) is proportional to the total (initial) enzyme concentration CET. 2. At low (initial) concentration of substrate Cs, the initial rate (–rso) is first order with respect to the substrate. 3. At high Cs, (–rso) is independent of (initial) Cs. The effect of temperature satisfies the Arrhenius relationship where the applicable range is relatively small because of low and high temperature effects. The effect of extreme pH values is related to the nature of enzymatic proteins as polyvalent acids and bases, with acid and basic groups (hydrophilic) concentrated on the outside of the protein. Finally, mechanical forces such as surface tension and shear can affect enzyme activity by disturbing the shape of the enzyme molecules. Since the shape of the active site of the enzyme is constructed to correspond to the shape of the substrate, small alteration in the structure can severely affect enzyme activity. Reactor’s stirrer speed, flowrate, and foaming must be controlled to maintain the productivity of the enzyme. Consequently, during experimental investigations of the kinetics enzyme catalyzed reactions, temperature, shear, and pH are carefully controlled; the last by use of buffered solutions.
MODELS OF ENZYME KINETICS Consider the reaction S → P occurs with an enzyme as a catalyst. It is assumed that the enzyme E and substrate S combine to form a
Biochemical Reaction
835
complex ES, which then dissociates into product P and free (uncombined) enzyme E.
r
k1
E + S [ ES* k2
k
ES* 3 → E + P
(1-93) (1-94)
r The net rate of disappearance of S is:
(− rs )net = k1C E CS − k 2C ES∗
(11-1)
At pseudo equilibrium (–rs) = 0, implying that the steps are very rapid: k1C E C S = k 2 C ES∗ Km =
k 2 C E CS = k1 C ES∗
where Km CE CS C ES*
= = = =
(11-2)
(11-3)
the dissociation equilibrium constant for ES* concentration of the enzyme, E concentration of the substrate, S concentration of the complex, ES*
The concentration of the enzyme-substrate complex from Equation 11-3 is k1 C E CS k2
C ES∗ =
(11-4)
Decomposition of the complex to the product and free enzyme is assumed irreversible, and rate controlling: 3 ES∗ →P +E
k
(11-5)
The formation rate of the product P is
v ≡ ( rP ) = k 3C ES∗
(11-6)
836
Modeling of Chemical Kinetics and Reactor Design
C ES* and CS are related by a material balance on the total amount of enzyme, CET. C E + C SE ∗ = C ET
(1-101)
Combining Equations 11-4 and 1-101 gives k 2 C ES∗ + C ES∗ = C ET or k1 C S
C ES∗ = =
k1C SC ET k 2 + k1C S C SC ET k2 + CS k1
(11-7)
Combining Equations 11-6 and 11-7 yields v = ( rP ) =
=
k 3C SC ET k2 + CS k1
k 3C SC ET (K m + Cs )
(11-8)
where Km in this instance is referred to as the Michaelis-Menten [7] constant. rp is expressed as a reaction velocity. Figure 11-1a shows the effect of the substrate concentration CS on the reaction rate (–rS) according to simple Michaelis-Menten kinetics.
(− rS ) = K max+ CS V
m
C
(11-9)
S
where Vmax = k 3C ET
(11-10)
Biochemical Reaction
837
Figure 11-1a. Simple Michaelis-Menten kinetics.
At low substrate concentration K m >> C S and
(− rS ) ≈
Vmax C S Km
(11-11)
At high substrate concentration C S >> K m
(− rS ) ≅ Vmax
(11-12)
When the substrate concentration is such that the reaction = (1/2)Vmax
(− rS ) = K max+ CS V
m
C
S
=
Vmax 2
Solving Equation 11-13 for the Michaelis constant gives
(11-13)
838
Modeling of Chemical Kinetics and Reactor Design
2C S1 2 K m + C S1 2
=1
K m = C S1 2
(11-14)
The Michaelis constant is equal to substrate concentration at which the rate of reaction is equal to one-half the maximum rate. The parameters Km and Vmax characterize the enzymatic reactions that are described by Michaelis-Menten kinetics. Vmax is dependent on total enzyme concentration CET (Equation 11-10), whereas Km is not. Enzymatic reactions frequently undergo a phenomenon referred to as substrate inhibition. Here, the reaction rate reaches a maximum and subsequently falls as shown in Figure 11-1b. Enzymatic reactions can also exhibit substrate activation as depicted by the sigmoidal type rate dependence in Figure 11-1c. Biochemical reactions are limited by mass transfer where a substrate has to cross cell walls. Enzymatic reactions that depend on temperature are modeled with the Arrhenius equation. Most enzymes deactivate rapidly at temperatures of 50°C–100°C, and deactivation is an irreversible process.
Figure 11-1b. Substrate inhibition.
Biochemical Reaction
839
Figure 11-1c. Activation.
If Vmax, the maximum velocity replaces k3CET in Equation 11-8, yielding
( rP ) =
Vmax C S K ( m + CS )
(11-15)
Equation 11-15 is known as the Michaelis-Menten equation. It represents the kinetics of many simple enzyme-catalyzed reactions, which involve a single substrate. The interpretation of K m as an equilibrium constant is not universally valid, since the assumption that the reversible reaction as a fast equilibrium process often does not apply. PARAMETERS IN THE MICHAELIS-MENTEN EQUATION The Michaelis-Menten Equation 11-15 is not well suited for estimation of the kinetic parameters Vmax and Km. Rearranging Equation 11-15 gives various options for plotting and estimating the parameters.
v=
Vmax C S K m + CS
(11-16)
840
Modeling of Chemical Kinetics and Reactor Design
Rearranging Equation 11-16 gives
K 1 1 1 = + m v Vmax Vmax C S
(11-17)
Equation 11-17 is referred to as a Lineweaver-Burk equation involving separate dependent and independent variables 1/v and 1/CS, respectively. Equation 11-17 can be further rearranged to give
CS K 1 = m + CS v Vmax Vmax or
v = Vmax − K m
v CS
(11-18)
Equation 11-18 is referred to as the Eadie-Hofstee equation, where v is plotted against v/CS. However, both of these equations are subjected to large errors. Equation 11-18 in particular contains the measured variable v in both coordinates, which is subjected to the largest errors. Figures 11-2 and 11-3 show plots of Lineweaver-Burk and EadieHofstee equations, respectively. BRIGGS-HALDANE MODEL Briggs and Haldane [8] proposed a general mathematical description of enzymatic kinetic reaction. Their model is based on the assumption that after a short initial startup period, the concentration of the enzymesubstrate complex is in a pseudo-steady state (PSS). For a constant volume batch reactor operated at constant temperature T, and pH, the rate expressions and material balances on S, E, ES*, and P are
(+ rS ) =
dC S = k 2 C ES∗ − k1C E C S dt
(+ rES ) =
dC ES∗ dt
= k1C E C S − k 2 C ES∗ − k 3C ES∗
The total concentration of the enzyme and the substrate is
(11-19)
(11-20)
Biochemical Reaction
Figure 11-2. Lineweaver-burk plot.
Figure 11-3. Eadie-Hofstee plot.
841
842
Modeling of Chemical Kinetics and Reactor Design
C ET = C E + C ES∗
(1-101)
C ST = C S + C ES∗ + C P
(11-21)
Rearranging Equation 1-101 and substituting in Equations 11-19 and 11-20, gives
(
dC S = k 2 C ES∗ − k1C S C ET − C ES∗ dt
(
dC ES∗
)
)
= k1C S C ET − C ES∗ − ( k 2 + k 3 )C ES∗
dt
(11-22)
(11-23)
With the initial conditions, at t = 0, CS = CST, and C ES* = 0 Equations 11-22 and 11-23 can be solved numerically, using any of the numerical methods in Appendix D. The results are used to determine CE(t) and CP(t) from Equations 1-101 and 11-21. Applying the stationary state hypothesis to the intermediate complex ES*, (CET K CST), ( dC ES∗ /dt) = 0, Equation 11-23 becomes 0 = k1CSCET – k1CS C ES∗ – (k2 + k3) C ES∗ or
C ES∗ =
k1C SC ET k1C S + k 2 + k 3
(11-24)
Substituting C * in the formation rate of the product P in EquaES tion 11-6 gives
k k 3C SC ET 1 S + k2 + k3
(+ rP ) = k 3C ES∗ = k C1 (+ rP ) =
k 3C SC ET K m + CS
where the Michaelis-Menten constant Km is now Km =
k2 + k3 k1
(11-25)
(11-26)
Biochemical Reaction
843
If k2 k k3, Equation 11-26 simplifies to the form of Equation 11-8. Substituting Vmax = k3CET in Equation 11-26 yields rP =
Vmax C S K m + CS
(11-27)
LINEARIZED FORM OF THE INTEGRATED MICHAELIS-MENTEN (MM) EQUATION For a constant volume batch reactor, the MM equation gives a form of an equation that can be linearized. Using Equation 11-15 gives
(+ rP ) = (− rS ) =
− dC S V C = max S dt K m + CS
(11-28)
Rearranging Equation 11-28 gives
(K m + CS ) –Km
dC S = − Vmax dt CS
(11-29)
dC S – dC S = Vmax dt CS
(11-30)
Integrating Equation 11-30 with the boundary conditions CS = CSO at t = 0 gives C – K m ln S – (C S − C SO ) = Vmax t C SO
(11-31)
Equation 11-31 can further be rearranged to give 1 C SO Vmax 1 C SO − C S ln − = t CS Km Km t
(11-32)
Equation 11-32 shows 1/t ln(CSO/CS) as a linear function of (CSO – C S)/t. The parameters Km and V max can be estimated from Equation 11-32 using measured values of CS as a function of t for a given
844
Modeling of Chemical Kinetics and Reactor Design
C SO. Figure 11-4 shows the corresponding plot in terms of substrate concentration. Example 11-1
The enzyme triose phosphate isomerase catalyzes the interconversion of D-glyceraldehyde 3–phosphate and dihydroxyacetone phosphate. CHO • CH(OH ) • CH 2 OPO32 − ⇔ CH 2 OH • CO • CH 2 OPO32 − The following results refer to the initial reaction velocity, v, with glyceraldehyde 3–phosphate (S) as substrate at a total enzyme concentration CET = 2.22 × 10–10M, pH = 7.42, and 30°C (Putman et al. [9]). 103 [S]/M 107 v/Ms–1
0.071 1.31
0.147 2.45
0.223 3.37
0.310 3.90
0.602 5.63
1.47 7.47
2.60 8.17
Figure 11-4. Evaluating Km and Vmax from 1/t ln(CSO/CS) versus (CSO – CS)/t plot.
Biochemical Reaction
845
Determine the Michaelis constant Km and the catalytic constant k3 for the enzyme under these conditions. Solution Using the developed computer program PROG1, the model equation 1/Y = A + B * 1/X represents the Lineweaver-Burk plot represented by Equation 11-17 as:
K 1 1 1 = + m v Vmax Vmax C S
(11-17)
The results of the regression analysis with the intercept and slope are: A = 0.9945 × 10–1 B = 0.4469 × 10–1 1 Vmax
(10 −7 ) = A = 0.9945 × 10 −1
Vmax = 1.0055 × 10–6 Ms–1
Km = Slope × 10 4 = B × 10 4 Vmax = 0.4669 × 10–1 × 104 K m = (0.4469 × 10 −1 ) (1.0055 × 10 −6 ) (10 4 ) K m = 4.7 × 10 −4 M The catalytic constant k3 is determined from Equation 11-10.
Vmax = k 3C ET or k 3 =
Vmax 1.0055 × 10 −6 = C Et 2.22 × 10 −10
(11-10)
846
Modeling of Chemical Kinetics and Reactor Design
k 3 = 4.53 × 10 3 s −1 Figure 11-5 shows the Lineweaver-Burk plot of 1/v versus 1/Cs. Example 11-2
At a particular room temperature, results for the hydrolysis of sucrose, S, catalyzed by the enzyme invertase (CET = 1 × 10–5 mol L–1) in a batch reactor are given by: CS/mmol L–1 t/h CS/mmol L–1 t/h
1 0 0.16 6
0.84 1 0.09 7
0.68 2 0.04 8
0.53 3 0.018 9
0.38 4 0.006 10
0.27 5 0.0025 11
Source: Missen, R. W. et al. [10].
Figure 11-5. Double reciprocal (Lineweaver-Burk) plot to determine Km and k3.
Biochemical Reaction
847
Determine the values of the kinetic parameters Vmax, Km, and k3. Solution Using Equation 11-26 for the batch reactor, the dependent variable 1/t ln(CSO/CS) is plotted as a function of the independent variable (CSO – CS)/t. A linear plot gives a slope = –1/Km and an intercept = Vmax/ Km. The values of Km and Vmax are determined from the slope and the intercept. k3 is evaluated from Vmax = k3CET, or
k3 =
Vmax C ET
(11-10)
Using the Microsoft Excel spreadsheet (EXAMPLE11-2.xls), a regression analysis was carried out giving the slope = –4.9967 L/mmol.
− Slope = −
1 Km
Km = 0.2 mmol/L V 1 Intercept = max = 0.9995 hr K m
mmol Vmax = 0.2 × 0.9995 hr • L k3 = =
Vmax C Et
(0.2 × 10 −3 ) mol • L (1 × 10 −5 ) hr • L mol
= 20 hr −1 Figure 11-6 shows a plot of 1/t ln(CSO/CS) versus (CSO – CS)/t.
848
Modeling of Chemical Kinetics and Reactor Design
Figure 11-6. 1/t ln(C SO/C S) versus (CSO – CS)/t plot.
TREATMENT OF MICHAELIS-MENTEN (MM) EQUATION A limitation of the linearized forms of the MM equation is that no accurate estimates of K m and V max can be established. Using the computer program PROG1, it is still impossible to obtain meaningful error estimates of the parameters because linear regression is an inappropriate method of analysis. There is an increasing trend toward using the integrated rate equation and non-linear regression analysis to estimate Km and Vmax. This technique is more complex than the linear regression method and provides additional benefits. First, accurate non-biased estimates of Km and Vmax can be determined. Second, non-linear regression may allow the errors (or confidence intervals) of the parameters to be evaluated. Software packages with greater sophistication and graphical displays
Biochemical Reaction
849
are now commercially available. This software enables designers and modelers to explore various options or incorporate developed models for analysis. The web sites of these software packages are: http:// www.ebicom.net/~dhyams/cvxpt.htm, http://www.graphpad.com, and http://www.mathsoft.com. NON-LINEAR REGRESSION USING THE SOLVER In this chapter, the Microsoft Solver Excel’s powerful optimization package is used to perform non-linear least squares curve fitting. Procedures for using the Solver are illustrated in Appendix B. The Solver provides results that are comparable with those from the commercial software packages. The Solver determines the sets of leastsquares regression coefficients very quickly and efficiently. The slight differences between the Solver and commercial software packages arise from the fact that the coefficients are found by a search method; the final values will differ depending on the convergence criteria used in each program. Example 11-3
A non-linear regression analysis is employed using the Solver in Microsoft Excel spreadsheet to determine the values of Km and Vmax in the following examples. Example 1-5 (Chapter 1) involves the enzymatic reaction in the conversion of urea to ammonia and carbon dioxide and Example 11-1 deals with the interconversion of D-glyceraldehyde 3–Phosphate and dihydroxyacetone phosphate. The Solver (EXAMPLE11-1.xls and EXAMPLE11-3.xls) uses the Michaelis-Menten (MM) formula to compute vcal. The residual sums of squares between vobs and vcal is then calculated. Using guessed values of Km and Vmax, the Solver uses a search optimization technique to determine MM parameters. The values of Km and Vmax in Example 11-1 are:
K m, M VmaxMs–1
Lineweaver-Burk method
Non-linear regression method
Percentage deviation (%)
4.7 × 10–4 10.055 × 10–7
4.286 × 10–4 9.574 × 10–7
8.8 4.78
The values of Km and Vmax in Example 1-5 are:
850
Modeling of Chemical Kinetics and Reactor Design
Lineweaver-Burk Non-linear method regression method kmol m3 kmol Vmax, m3 • s K m,
Percentage deviation (%)
0.0142
0.0539
73.7
0.852
1.7032
50.0
Figures 11-7 and 11-8 show plots of velocity versus substrate concentration of the interconversion of D-glyceraldehyde 3-Phosphate, and the conversion of urea, respectively.
Figure 11-7. Velocity versus substrate concentration plot.
Biochemical Reaction
851
Figure 11-8. Velocity versus substrate concentration plot.
ENZYME KINETICS IN THE PRESENCE OF AN INHIBITOR The three most common types of inhibitors in enzymatic reactions are competitive, non-competitive, and uncompetitive. Competitive inhibition occurs when the substrate and inhibitor have similar molecules that compete for the identical site on the enzyme. Non-competitive inhibition results in enzymes containing at least two different types of sites. The inhibitor attaches to only one type of site and the substrate only to the other. Uncompetitive inhibition occurs when the inhibitor deactivates the enzyme substrate complex. The effect of an inhibitor is determined by measuring the enzyme velocity at various
852
Modeling of Chemical Kinetics and Reactor Design
substrate concentrations both in the presence and absence of an inhibitor. The inhibitor substantially reduces the enzyme velocity at low substrate concentrations, but does not alter the velocity considerably at very high concentrations of substrate (Figure 11-9). Figure 11-9 shows that the inhibitor does not alter Vmax, but increases the observed Km (i.e., concentration of the substrate that produces half the maximal velocity in the presence of a competitive inhibitor). The observed Km is defined by [Inhibitor ] K mobs = K m 1 + Ki
(11-33)
where Ki = dissociation constant for inhibitor binding. Rearranging Equation 11-33 yields Ki =
Inhibitor K m, obs − 1 Km
(11-34)
A more reliable determination of Ki is achieved if the observed Km is determined at various concentrations of inhibitor. Each curve is then fitted to determine the observed Km. The inhibitor is entered as the
Figure 11-9. Enzyme velocity versus substate concentration.
Biochemical Reaction
853
independent variable and Km,obs as the dependent variable. A linear graph infers that the inhibitor is competitive. The slope and intercept can be determined using linear regression as shown in Figure 11-10. Competitive and non-competitive inhibitions are easily distinguishable from the Lineweaver-Burk plot. In the case of competitive inhibitors, the intercept on the 1/CS axis increases while the intercept of the 1/v axis remains unchanged by the addition of the inhibitor. Conversely, with a non-competitive inhibitor, only the 1/v axis intercept increases. The effect of competitive inhibitors can be reversed by increasing the substrate concentration. Where the enzyme or the enzyme substrate complex is made inactive, a non-competitive inhibitor decreases Vmax of the enzyme, but Km remains constant.
FERMENTATION Fermentation* processes use microbiology in producing chemical compounds that are made naturally. Cheap synthetic processes with abundant raw materials are now superseding fermentation processes that have produced commodity chemicals (e.g., ethanol, butanol, and
Figure 11-10. Km,obs versus inhibitor plot. *
The term “fermentation” is often used loosely by biochemical engineers. Biochemists have a more focused perspective (anaerobic) catabolism of an organic compound in which the compound serves as both an electron donor and acceptor and in which ATP is produced.
854
Modeling of Chemical Kinetics and Reactor Design
acetone). However, fermentation processes are still prominent for producing complex organic chemicals such as citric and lactic acids derived from low-cost carbohydrate sources. The pharmaceutical industry has employed materials of plant and animal origin as sources of drugs. The industry has utilized the life processes of either plants or animals and microorganisms to produce medicinal and antibiotic products. Microorganisms are bacteria, yeast, and molds that feed on organic materials. The supply of adequate energy foods coupled with other required nutrients will not only cause these microvegetative organisms to grow and multiply, but will change the food into other chemical substances. Yeast and bacteria are unicellular and of very small dimensions. Yeasts are irregularly oval and around 0.004 to 0.010 mm in diameter. Bacteria are smaller, less than 0.007 mm, and more diverse in shape. Many bacteria are rod-shaped and the bacteria multiply by binary fission. On the other hand, yeast multiplies by budding. Molds are multicellular filaments, which increase by vegetative growth of the filament. The vegetative reproduction cycle of these bacteria and of yeast is short (that is, measured in minutes), and therefore they multiply quite fast. Fermentation under controlled conditions involves chemical conversions. It is the action of specific microorganism on a substrate to produce the desired chemical compound. The majority of fermentation processes require oxygen and are classified as aerobic. The few processes carried out in the absence of air are classified as anaerobic. Certain anaerobes neither grow nor function in the presence of air. However, conditions can be controlled to encourage both the multiplication of the vegetative organisms and its performance either directly or through the secreted enzymes. Nutrients such as phosphates and nitrogenous compounds at controlled temperature and pH are added during the growth period. pH, temperature, aeration-agitation, pure culture, and yields influence the fermentation process. Optimizing the yield often requires reducing the quantity of the microorganism. A particular strain of an organism is used to produce the required chemical with the greatest yields, the least by-product, and at a low cost. The yeast, bacteria, and molds used in fermentation require both nutrients and specific environments to perform their activities (e.g., sugar concentration or other nutrients), which subsequently affect the product. The most favorable temperature varies from 5°C to 40°C, and pH also exerts a great influence on the process.
Biochemical Reaction
855
Generally, the fermentation process involves the addition of a specific culture of microorganisms to a sterilized liquid substrate or broth in a tank (submerged fermentation), addition of air if aerobic, in a well-designed gas-liquid contactor. The fermentation process is then carried out to grow microorganisms and to produce the required chemicals. Table 11-1 lists examples of the processes used by fermentation. The fermentation process can be performed batch-wise or continuously at a given temperature and time. The broth is further processed to remove the desired chemical. Figure 11-11 shows a schematic and an abstracted physical model of a fermenter with the liquid phase as the control region.
DESIGN OF BIOLOGICAL REACTORS TRANSPORT PHENOMENA INFLUENCE IN BIOREACTOR DESIGN The design basis is the most important consideration when determining the size of a biological reactor. Other pertinent factors are the final product, the microorganism used, its growth rate and oxygen requirement, the product concentration (e.g., expressed in mg/L broth for proteins or 100 mg/L for organic acids), and the type of product (intercellular or extracellular).
Table 11-1 Processes used by fermentation Oxidation
Reduction
Hydrolysis
Esterification Hexose phosphate from hexose and phosphoric acid
Alcohol to acetic acid
Aldehydes to alcohols (e.g., acetaldehyde to ethyl alcohol)
Starch to glucose
Sucrose to critic acid
Sulfur to hydrogen sulfide
Sucrose to glucose and fructose and on to alcohol
Dextrose to gluconic acid
856
Modeling of Chemical Kinetics and Reactor Design
Figure 11-11. A schematic and an abstracted physical model of a fermenter.
Additionally, three different phenomena are essential factors in the design of a bioreactor. These phenomena are: • Thermodynamics • Microkinetics • Transport These phenomena principally govern the performance of a bioreactor. The first and second of these phenomena are independent of scale. Neither a typical thermodynamic property (e.g., the solubility of oxygen in a broth) nor microkinetic properties (e.g., the growth and product formation by the microorganism) are dependent on the scale of the bioreactors. However, the actual oxygen concentrations and the kinetic behavior of microorganisms in a bioreactor are dependent on
Biochemical Reaction
857
scale. The reason is that oxygen and other nutrients involved in the conversion processes are consumed rapidly, and have to be supplied by transport processes. Scale-up influences these transport processes resulting in the existence of gradients at production scale. When the microorganism travels through the bioreactor, it encounters constantly changing concentrations of nutrients, oxygen, and pressure. Additionally, the microorganisms are always subjected to (turbulent) shear phenomena, which can damage the microorganism, the cell itself, or influence the formation of agglomerates (floc, pellets) of microorganisms. Scale-up problems are prevalent in aerobic processes for continuous and fed-batch productions than for batch type involving the transport of oxygen and nutrients to the microorganisms. Transport phenomena are governed mainly by flow and diffusion, and these depend on the shear, mixing, mass transfer (kLa), heat transfer, and macrokinetics (i.e., a form of apparent kinetics resulting from a combination of microkinetics and diffusion occurring in immobilized systems, flocs, and pellets). These phenomena will change during scale-up together with the kinetic behavior of microorganism, which depends on local environmental conditions. Biological reactors play a valuable role in the conversion of substrates by microorganisms and mammalian cells into a wide range of products such as antibiotics, insulin, and polymers. Figures 11-12, 11-13, and 1114 illustrate various types of biological reactor, and Figure 11-15 shows the physical characteristics of a typical commercial fermentation vessel.
VESSEL DESIGN AND ASPECT RATIO A vertical cylindrical, and mechanical agitated pressure vessel, equipped with baffles to prevent vortex formation is the most widely used fermenter configuration. The baffles are typically one-tenth of the fermenter diameter in width, and are welded to supports that extend from the sidewall. A small space between the sidewall and the baffle enables cleaning. Internal heat transfer tube bundles can also be used as baffles. The vessels must withstand a 45 psig internal pressure and full vacuum of –14.7 psig, and comply with the ASME code. Standard components for a bioreactor comprise the vessel, the agitator and impeller, heat exchangers, seals, and valves. Other components include utilities such as clean-in-place (CIP), and steam-inplace (SIP) systems, auxiliary tanks, pH and foam control, inlet tubes, (text continued on page 862)
858
Modeling of Chemical Kinetics and Reactor Design
Figure 11-12. Reactors with mechanical stirring: M, moter; G, gas (air); SB, baffles; LR, conduit tube; SZ, foam breaker; W, roller; F, liquid. (Source: Schuger [11].)
Biochemical Reaction
859
Figure 11-13. Reactors stirred by pumped fluid: ID, Injector nozzle; SK, float; G, gas; F, liquid. (Source: Schuger [11].)
860
Modeling of Chemical Kinetics and Reactor Design
Figure 11-14. Reactors with energy input by compression. (Source: Schuger [11].)
Biochemical Reaction
861
Figure 11-15. Cutaway diagram of a 1,000,000 liter fermenter used for penicillin production. (Source: Aiba et al. [12].)
862
Modeling of Chemical Kinetics and Reactor Design
(text continued from page 857)
instrumentation, and control systems. Standard good engineering practice is essential during both design and scale-up procedures. For example, the U.S. requires Current Good Manufacturing Practices (CGMP) as mandated by the Food and Drug Administration, which stipulates minimum design requirements and guidelines in areas such as equipment, documentation, operation, and maintenance. The vessel should be designed to operate monoseptically over a range varying from 18 h–30 days depending on the type of fermentation [13]. Operation must be reliable, repeatable, sterile, and automated. Manual operations are susceptible to variables that can be introduced into the process resulting in the risk of contamination and, consequently, a high operating cost. The aspect ratio AR (i.e., the ratio between the vessel’s height, which is the distance along the sidewall to its diameter, H:D) is essential when specifying the vessel’s agitation requirements. The AR varies between 1.2 to 3.0. Fermenters with a H:D ratio greater than 1.5 may require multiple impellers for adequate mixing. The distance between the impellers is two-thirds of the tank diameter or the horizontal length of an impeller blade. The highest impeller is one horizontal blade diameter below the surface of the aerated volume. The second impeller from the bottom provides the major portion of bulk mixing and features axial-flow or high efficiency turbine-type blades (see Chapter 7). Aspect ratios are significant factors in specifying the vessel’s agitation requirements. A high AR presents problems in mixing, which can affect the heat transfer, pH control, and oxygen mass transfer. Fermenters with low air flow requirements and an AR higher that 3:1 can cause an accumulation of carbon dioxide. This is usually toxic to the microbe and results from poor mixing. AR as an essential design parameter in vessel scale-up is reviewed in Chapter 13. An ASME 2:1 elliptical heads can ensure an increase in pressure resistance of the vessel. Fermenter jackets (e.g., half-pipe, diameter, or true type) should be constructed to sustain the vessel’s rated pressure and, thus, enhance its strength. The construction material is type 316L stainless steel, which features an internal mechanical-polish finish of 2B-mill or 25-Roughness Average (Ra)* depending on the nature of the fermentation. *
2B mill is a measurement of roughness, which is at the higher end of the scale. Roughness average (Ra) is a biotechnology industry standard. 25Ra is smoother than 2B mill. As a rule, the higher the Ra number, the rougher the finish.
Biochemical Reaction
863
TYPES OF OPERATION The mode of operation, which can be batch, fed-batch, or continuous, should be considered during the preliminary stages of largescale design. Batch operation often involves simplicity in maintenance of aseptic conditions and minimizes operating losses due to contamination or equipment failure. In contrast, fed-batch type involves feeding the reactor with fresh nutrients or carbohydrates or both during fermentation when low glucose concentrations (10–50 mg/L) are required to maintain the productivity of microorganism. Most fermentations employ a single microorganism, thus it is essential to grow the microbe in a pure culture without contamination from other undesirable microbes. Continuous biological reactors are seldom used. This is due to the difficulty of maintaining monosepsis (i.e., preventing contamination by foreign organisms) coupled with the challenge in controlling the different phases of the microorganism’s growth rate. Mathematical models are developed for the batch, fedbatch, and continuous biological reactors later in this chapter. The desired product in the fermentation process depends on the pertinent condition used, the type of microorganisms (e.g., bacteria, fungi, and mammalian cell lines), and on economic factors. The various types of product are: • The microorganism manufactures the product, which may be an organic acid, an alcohol, an enzyme or other protein, an amino acid, a vitamin, an antibiotic, or other therapeutic protein. • The microorganism transforms a substance into one or higher values during a biconversion process. • The product itself is the microorganism, for example Baker’s Yeast and veterinary or human biological or vaccines.
CELL GROWTH Typical batch fermentation begins with an initial charge of cells referred to as inoculum. Here, the number of living cells varies with time as shown in Figure 11-16. During the initial lag phase, cells are adjusting themselves to the new environment. During this period, the cells perform functions as synthesizing transports proteins for moving
864
Modeling of Chemical Kinetics and Reactor Design
Figure 11-16. Typical growth phase in batch fermentation.
the substrate into the cell. Most microbes and particularly bacteria are adaptable and can utilize various carbon sources. Generally, one or more unique enzymes are required for each source and these must be manufactured by the cell in response to the new environment. These are referred to as induced enzymes. Additionally, the duration of the lag phase depends on the growth medium, such as the reactor from which the inoculum is obtained relative to the reaction medium where it is placed. The manufacture of desirable products is negligible during the lag phase. After the lag phase, a period of rapid growth develops during which the cell numbers increase exponentially with time. In this phase, the cells are dividing at the maximum rate because all the enzyme’s pathways for metabolizing the media are in place. During the exponential growth phase, the total cell mass increases by a fixed percentage during each time interval, and the cells are able to use the nutrients most efficiently. In a closed vessel, the cells cannot multiply indefinitely, and a stationary phase follows the period of exponential growth. At this point, the population achieves its maximum size. In semi-batch fermentations, a linear growth phase occurs when some key reactants
Biochemical Reaction
865
are supplied at a fixed rate. If the limiting reactant is oxygen, the supply rate is affected by mass transfer considerations. In fed batch fermentations, the limiting reactant is the substrate (e.g., glucose), which is fed to the system at a fixed rate. A stationary population can be maintained using continuous culture techniques. During the stationary phase, the growth rate is zero as a result of the depletion of nutrients and essential metabolites. Several important fermentation products (including most antibiotics) are produced in the stationary phase. The stationary phase is followed by a phase where cells die or sporulate. During the death phase, there is a decrease in live cell concentration, which results from the toxic byproducts coupled with the depletion of the nutrient. The number of viable cells usually follows an exponential decay curve during this period. Each phase in Figure 11-16 is recommended in microbiological processes. For example, a design objective may require minimizing the length of the lag phase or maximizing the rate and length of the exponential phase. The latter objective is achieved by slowing the onset of the transition to stationary growth. Knowledge of parameters that influence the phase of batch growth is essential to attain the largest possible cell density at the end of the process. Microbial cultures are very sensitive systems and, therefore, high demands are required for both control and monitoring of a biochemical reactor. Additionally, off-line analysis of liquid chromatograph or enzymatic assay techniques can also be employed for measurement of substances associated with the process of growth as substrates and products. The growth of an aerobic organism can be represented by Substrate cells → more cells + product
GLUCONIC ACID PRODUCTION Consider the fermentation of glucose to gluconic acid, which involves the oxidation of the aldehyde group (RCHO) of the sugar to a carboxyl group (RCOOH). The industrial production of gluconic acid is by strains of Aspergillus and Pseudomonas ovalis. The enzyme that catalyzes the oxidation of glucose is a dehydrogenase (and not an oxidase), which is capable of transforming glucose to gluconolactone. Gluconic acid is produced by the hydrolysis of the gluconolactone, which can be either enzymatic or a non-enzymatic process. The enzyme that is required for the hydrolysis step is gluconolactonase,
866
Modeling of Chemical Kinetics and Reactor Design
although the presence of this enzyme in Aspergillus and Pseudomonas has not been revealed. Rai and Constantinide [14] considered the hydrolysis stage as a non-enzymatic process. The byproduct of the reaction is decomposed to water and oxygen by the enzyme catalase, which is present in the living cells. Gluconic acid is extensively used in the food, pharmaceutical, and a wide range of products. In the textile industries, gluconic acid, glucono-δ-lactone, and ammonium gluconates are used in acid catalysts. Gluconates are incorporated in antibiotic complexes (e.g., tetracyline) to improve stability, lower the toxicity, and increase antibiotic levels in the blood. Calcium gluconates are employed for treating calcium deficiencies in both humans and animals. The hydrogen peroxide produced in the glucose oxidase catalyzed reaction contains an antibacterial action. The addition of a catalase converts the hydrogen peroxide to water and oxygen. Reaction Mechanisms The reaction mechanisms in the fermentation of glucose to gluconic acid are: 1. Cell growth:
Glucose + cell → more cells For example, C6H12O6 + cells → more cells
(1-34)
2. Glucose oxidation: oxidase Glucose + O 2 Glucose → gluconolactone + H 2 O 2
For example, oxidase C 6 H12 O 6 + O 2 Glucose → C 6 H10 O 6 + H 2 O 2
3. Gluconolactone hydrolysis: Gluconolactone + H 2 O → gluconic acid
(1-35)
Biochemical Reaction
867
For example, C6H10 + H2O → C5H11O5COOH
(1-36)
4. Hydrogen peroxide decomposition: For example,
1 H 2 O 2 Catalase → H 2 O + O 2 2
(1-37)
Mathematical Modeling Rai and Constantinides [14] developed a mathematical model for the fermentation of the bacterium Pseudomonas ovalis, which converts the glucose to gluconic acid. The following equations describe the dynamics of the logarithmic growth phase: The rate of cell growth: dC A C = b1 C A 1.0 − A dt b2
(11-35)
The net rate of gluconolactone formation:
dC B b 3C A C D = − 0.9082 b 5C B dt b4 + CD
(11-36)
The rate of gluconic acid formation:
dC C = b 5C B dt
(11-37)
The rate of glucose consumption: b C C dC D = − 1.011 3 A D dt b4 + CD where CA = concentration of the cell CB = concentration of gluconolactone
(11-38)
868
Modeling of Chemical Kinetics and Reactor Design
CC = concentration of gluconic acid CD = concentration of glucose b1 – b5 = parameters of the system, which are functions of temperature and pH Rai and Constantinides [14] performed the fermentation experiments at 30°C and a pH of 6.6. They fitted the dynamic equations (Equations 11-35 to 11-38) to the experimental data using the non-linear regression method developed by Marquardt [15] to evaluate the values of the parameters b1 to b5. The values of the parameters are: b1 = 0.949, b2 = 3.439, b3 = 18.72, b4 = 37.51, b5 = 1.169. At these conditions and known parameters, a computer program using the Runge-Kutta-Gill method was developed (PROG11-1) to simulate the changes in concentrations of the cells, gluconolactone, gluconic acid, and glucose with time for a period of 10 hrs (i.e., 0 ≤ t ≤ 10 hrs). The initial conditions at the start of this period were: CA(0) CB(0) CC(0) CD(0)
= = = =
0.5 U.O.D./mL (cell optical density) 0.0 mg/mL 0.0 mg/mL 50.0 mg/mL
Table 11-2 gives the results of the computer simulation and Figure 11-17 shows the concentration profiles of the cell, gluconolactone, gluconic acid, and glucose with time. These profiles are in good agreement with the experimental data of Rai and Constantinides [14].
MODELING BIOLOGICAL REACTORS A model can be defined as a set of relationships between the variables of interest in the system being investigated. A set of relationships may be in the form of equations; the variables depend on the use to which the model is applied. Therefore, mathematical equations based on mass and energy balances, transport phenomena, essential metabolic pathway, and physiology of the culture are employed to describe the reaction processes taking place in a bioreactor. These equations form a model that enables reactor outputs to be related to geometrical aspects and operating conditions of the system. For example, in a fermentation process, the modeler may be interested in various controlled parameters such as the feed rate, rate and mode
Biochemical Reaction
869
Table 11-2 Concentration of the cell, gluconolactone, gluconic acid, and glucose with time using the Runge-Kutta-Gill method
Figure 11-17. Concentration profiles of cell, glucose, gluconolactone, and gluconic acid with time.
870
Modeling of Chemical Kinetics and Reactor Design
of agitation, temperature, and the viability of the microorganism. Thus, constructing the mathematical model of a bioreactor from theoretical and empirical data enables the designer to predict the behavior and optimize the performance of the system. A fermentation model is an abstracted and generalized description of pertinent aspects of the process. The abstracted physical model (Figure 11-11) can be defined as a region in space throughout which all the variables of interest (e.g., temperature, concentration, pH) are uniform. This is referred to as the control region or control volume. The control region may be a constant volume (e.g., a chemostat or a simple batch fermentation) or it may vary in size (e.g., a fed batch fermenter). The control region may be finite as represented by a wellmixed fermenter or infinitesimal as depicted by a tower fermenter. In this case, the concentrations of substrate and product vary continuously throughout the liquid space, so that only an infinitesimal thin slice can be considered uniform. Such a reactor can be modeled as a series of infinitesimal control regions. The considered boundaries of the control regions are: • Phase boundaries across which an exchange of mass or energy occurs (e.g., the bubble-liquid interface). • Phase boundaries across which no exchange occurs (e.g., the walls of the containing vessel). • Geometrically defined boundaries within one phase across which exchanges occur either by bulk flow or by molecular diffusion (e.g., nutrient inlet and outlet pipes). Constructing a mathematical model involves developing a set of equations for each control region. This set consists of the following: 1. Balanced equations for each extensive property of the system (e.g., mass, energy, or individual species). 2. Rate equations. These are of two types, namely: • Rates of transfer of mass, energy, individual components, or species across the boundaries of the region. • Rate of generation or consumption of individual species within the control region. 3. Thermodynamic equations, which relate to thermodynamic properties (e.g., pressure, temperature, density, concentration), either within the control region (e.g., gas laws) or on either side of a phase boundary (e.g., Henry’s law).
Biochemical Reaction
871
A balanced equation for every extensive property in each control volume may be written as: rate of accumulation rate of input rate of output (11-39) = − in control region to control region from control region
The input terms can be classified as: • • • •
Bulk flow across geometrical boundaries. Diffusion across geometrical boundaries. Transfer across phase boundaries. Generation within the control region.
The output terms are: • • • •
Bulk flow across geometrical boundaries. Diffusion across geometrical boundaries. Transfer across phase boundaries. Consumption within the control region.
Bulk flow is expressed as the material or energy carried by the bulk flow of fluid into or out of the control region.
MASS TRANSFER ACROSS PHASE BOUNDARIES Agitation and Oxygen Transfer The degree of both agitation and aeration must be considered simultaneously. Agitation will affect the transfer of oxygen from the gas phase into the liquid phase. The oxygen uptake rate (OUR), or the amount of oxygen that is required for cell growth per unit of cell mass and maintenance, can be determined from experimental data. This involves measuring the dissolved oxygen in a saturated fermentation broth and, subsequently, determining the rate at which the microbes use up the oxygen. Alternatively, OUR can be determined either by combining the stoichiometric ratio with the growth rate of the microorganism or from the method described by Roberts, et al. [16]. The oxygen transfer rate (OTR), or the rate at which oxygen is transferred from the gas to the liquid phase, must be a least equal to the peak oxygen load (OUR) at steady state, and can be determined from Equation 11-40:
872
Modeling of Chemical Kinetics and Reactor Design
OTR = k L a (C∗ − C L )
mean
(11-40)
where OTR = oxygen transfer rate, mmoles/L-h kLa = mass transfer coefficient, h–1 C* = oxygen concentration in equilibrium with the partial pressure of oxygen in the bulk gas phase, mmoles/L CL = concentration of dissolved oxygen in the fermentation broth, mmoles/L The generation or consumption terms are defined as follows: rx = growth rate of cells rp = production rate of some product rs = consumption rate of substrate A convenient method for measuring OTR in microbial systems depends on dissolved oxygen electrodes with relatively fast response times. Inexpensive oxygen electrodes are available for use with open systems, and steam-sterilizable electrodes are available for aseptic systems. There are two basic types: One develops a voltage from an electrochemical cell based oxygen, and the other is a polarographic cell whose current depends on the rate at which oxygen arrives. Measurement of oxygen transfer properties require a brief interruption of oxygen supply [17].
GENERAL MODEL FOR A SINGLE VESSEL Consider an idealized fermentation process in which growing cells are consuming substrate and producing more cells as represented by the following scheme.
Biochemical Reaction
where Cx Cs rsx rx
= = = =
873
cell concentration, kg/m3 substrate concentration, kg/m3 rate of substrate consumption, kg/m3•h rate of cell growth, kg/m3•h
Figure 11-18 shows the notations used in modeling and analysis of the fermentation process. The material balance on the microorganism in a CSTR at constant volume, assuming perfect mixing (i.e., concentrations of the cell and substrate inside and at the exit are the same) is expressed by: rate of accumulation rate of input rate of output = − (11-39) in control region to control region from control region
Cell balance: accumulation = (d/dt)(VCC) Input terms: bulk flow = uiCxi generation = rxV Output terms: bulk flow = uOCx
Figure 11-18. A chemostat with design parameters.
874
Modeling of Chemical Kinetics and Reactor Design
Substituting these terms in the material balance equation gives
V
dC C = u i C xi + rx VR − u O C x dt
(11-41)
Substrate balance: accumulation = (d/dt)(VCS) Input terms: bulk flow = uiCSi Output terms: bulk flow = uOCS consumption = rsxV The substrate material balance becomes: V
dC S = u i C Si − u O C S − rsx V dt
(11-42)
Additionally, the change in reactor (liquid) volume can be accounted for by
dV = ui − uo dt
(11-43)
Assuming that the reactor is well mixed and that the flowrate is constant (i.e., ui = uo = u), rearranging Equations 11-41 and 11-42 gives
dC x = D(C xi − C x ) + rx dt
(11-44)
dCs = D(Csi − Cs ) − rsx dt
(11-45)
where the dilution rate D is given by D=
u m3 1 • , which is the inverse of the residence time. V h m3
If there are no cells in the incoming medium (e.g., a sterile feed), Equation 11-44 becomes dC x = rx − DC x dt
(11-46)
Biochemical Reaction
875
Assuming rx and rsx are as follows: rx = µC x and rsx = µ
(11-47) Cx Yx s
(11-48)
where µ = specific growth rate, h–1 Yx/s = yield coefficient
Yx s =
mass of new cells formed kg of cells mass of substrate consumed kg of substrate
(11-49)
with Yx/s = 1/Ys/x. Equations 11-44 and 11-45 now become
dC x = (µ − D) C x dt and
dCs − µC x = + D(Csi − Cs ) dt Yx s
(11-50)
(11-51)
The specific growth rate will be assumed to take the form
µ (C s ) =
µ max Cs K s + Cs
(11-52)
where µmax = maximum specific growth rate Ks = the Monod constant The specific growth rate function µ(Cs) is written as µ. The various properties of Equation 11-52 are: when the substrate concentration is not limiting (i.e., Cs k Ks), the specific growth rate µ(Cs) approaches µmax; the growth rate of the viable cell (rv) becomes independent of Cs and is proportional to the viable cell concentration (Cxv).* *Viable cells mean cells which can grow; non-viable cells mean cells which cannot. Microbiologists use the same terms but can divide “non-viable” cells into cells, which remain metabolically active in some respects and cells which are effectively dead. They can also distinguish within their category of “viable” cells between cells, which are actively dividing, and cells such as spore cells whose growth activities are potential rather than actual.
876
Modeling of Chemical Kinetics and Reactor Design
µ C rx = µ(S)C xv = max s C xv K s + Cs
(11-53)
where C xv is the concentration of viable cell. When C s is small compared to Ks, the specific growth rate is nearly proportional to the limiting substrate concentration. At steady state, Equations 11-50 and 11-51 become
(µ − D) C x = 0 and D(Csi − Cs ) −
(11-54) µC x =0 Yx s
(11-55)
The generalized mass balance equation on a unit volume is: 1 d(Vy) = V dt
∑ rgen − ∑ rcons + D(y i − γy)
(11-56)
where y is the general extensive property, Cx, Cs, Cp, Cv, and Cd. These properties are defined as: Cx Cs Cp Cv Cd V ∑rgen ∑rcon γ
= = = = = = = = =
cell concentration substrate concentration product concentration viable cell concentration non-viable cell concentration reactor (liquid) volume sum of all the rates of generation sum of all the rates of consumption uo/ui
Figure 11-18a shows a flow diagram for constructing the mathematical model of a fermentation process.
THE CHEMOSTAT The chemostat is an arrangement for continuous fermentation in which the properties of the system are regulated by a controlled supply of some limiting nutrient. It is a powerful research tool in microbial physiology and for evaluating process parameters. The chemostat
Biochemical Reaction
877
Figure 11-18a. The scheme of constructing the mathematical model of a fermentation process. (Source: B. Volesky and J. Votruba [4].)
operates with a constant inflow and outflow, and it is assumed to be well mixed and that concentrations are uniform throughout the whole of the medium volume. Outflow concentrations are the same as those in the fermenter, and constant inflow and outflow medium ensures a constant reactor volume. The fermenter operation mode normally involves sterile feed (Cx = 0), and the cell growth rate can be controlled by adjusting
878
Modeling of Chemical Kinetics and Reactor Design
the volumetric feedrate (i.e., dilution rate). Figure 11-19 shows a chemostat with associated monitoring equipment and pH controller. DESIGN EQUATION The bioreactor involves sterile feed (Cx = 0) and constant volume; steady state conditions imply that
dV d d = (VCs ) = (VC x ) = 0 dt dt dt Applying the generalized form of the mass balance Equation 11-56, at constant density, dV/dt = 0. Because ui = u, γ = ui/u = 1, Equation 11-56 becomes
dy = dt
∑ rgen − ∑ rcon + D(y i − y)
(11-57)
The material balances are: Cell balance:
dC x = 0 + rx − DC x dt
Substrate balance:
dCs = D(Csi − Cs ) − rs dt
(11-58)
(11-59)
where D = u/V u = volumetric flow through the system V = reactor (liquid) volume
At steady state,
dCs dC x = =0 dt dt
Therefore, for the substrate balance u(Csi − Cs ) − rs V = 0
or
(11-60)
D(Csi − Cs ) − rs = 0
(11-61)
Figure 11-19. Chemostat system.
Biochemical Reaction 879
880
Modeling of Chemical Kinetics and Reactor Design
For the cell balance DCx = rx
(11-62)
Substituting Equation 11-47 into Equation 11-62 gives DCx = µCx or D = µ
(11-63)
The dilution rate D is equal to 1/t, where t = u/V, and is equal to the mean residence time of the tank. Equation 11-63 shows that controlling the dilution rate D (i.e., the flowrate into the reactor) can control the specific cellular growth rate of a microbial species µ. For the substrate balance, it is known from Equation 11-61 that D(Csi − Cs ) − rs = 0
or
(11-61)
D(Csi − Cs ) = + rs = D(Csi − Cs ) =
rx Yx s
D Cx Yx s
(11-64)
(11-65)
The cell concentration in terms of the substrate concentration and the yield coefficient is:
C x = Yx s (Csi − Cs )
(11-66)
The substrate concentration Cs is obtained from the Monod expression given by
µ=
µ max Cs =D K s + Cs
Rearranging Equation 11-67 yields
K s + Cs =
µ max Cs D
(11-67)
Biochemical Reaction
or Cs =
KsD (µ max − D)
881
(11-68)
Assuming that a single nutrient is limiting, and cell growth is the only process contributing to substrate utilization, substituting Equation 11-68 into Equation 11-66 and rearranging yields Cx =
Yx s (K s + Csi ) Csi µ max − D (µ max − D) K s + Csi
(11-69)
WASHOUT IN CONTINUOUS CULTURE A consequence of applying Equations 11-68 and 11-69 respectively in describing the chemostat, is that the maximum dilution rate is limited to a value that is slightly less than the maximum specific growth rate µmax. This is referred to as the critical dilution rate Dc. Washout occurs when cells are removed from the reactor at a rate (Dc • Cxv) that is just equal to the maximum rate at which they can grow. As the flowrate u increases, D increases and causes the steady state value of Cs to increase and the corresponding value of Cx to decrease, respectively. When D approaches µmax, Cx becomes zero, and Cs will rise to the inlet feed value Csi. This corresponds to a complete removal of the cells by flow out of the tank, and the condition of loss of all cells at steady state is known as “washout.” The dilution rate at which washout occurs can be determined by setting Cx = 0 in Equation 11-69. This becomes
µ max Csi − D max = 0 K s + Csi or D max =
µ max Csi K s + Csi
(11-70)
The rate of cell production per unit reactor volume is DCx. The maximum cell output rate is determined by solving d (DC x ) = 0 dD
(11-71)
882
Modeling of Chemical Kinetics and Reactor Design
Substituting for Cx gives
DC x = DYx s (Csi − Cs ) KsD = DYx s Csi − µ max − D
Y KsD2 d =0 DC x ) = x / s Csi D − ( dD dD (µ max − D)
(11-72)
Solving for Equation 11-71 yields for the maximum production
D max output
0.5 Ks = µ max 1 ± (K s + Csi )
(11-73)
The microbial growth rate (and hence the dilution rate) for maximum production (or consumption) must be below the maximum specific growth rate (and hence the critical dilution rate). Therefore, Equation 11-73 is given by
D max output
0.5 Ks = µ max 1 − (K s + Csi )
(11-74)
Figure 11-20 shows production rate, cell concentration, and substrate concentration as functions of dilution rate. From Equation 11-74, the maximum production rate can be determined. Example 11-4
(a) Given that the maximum specific growth rate of an organism is µmax = 1 h–1 and its Ks = 1.5 g/cm3. If the input substrate concentration is 145 g/cm3, determine the maximum output rate for this system in a CFSTR. (b) If the concentration of product at this maximum output rate is 10 g/cm3, determine the maximum output rate of the product.
Biochemical Reaction
883
Figure 11-20. Cell concentration and production rate as a function of dilution rate. (Source: Fogler [19].)
(c) If the concentration of biomass at this maximum output is 50 g/cm3, determine the cell mass formation rate at the maximum output rate. Solution (a) Using Equation 11-74, the maximum output rate in a CFSTR is:
D max output
0.5 Ks = µ max 1 − (K s + Csi )
= 11 −
1.5 1.5 + 145
= 0.8988 h −1 = 0.899 h −1
0.5
(11-74)
884
Modeling of Chemical Kinetics and Reactor Design
(b) The output rate of product is rP = D • CPI, at the maximum rp = Dmax output • CPI 1 g rP = 0.899 • 10 • h cm 3
rP = 8.99
g cm 3 h
(c) The cell mass formation rate at the maximum output rate is: rM = D max output • C MI g 1 = 0.899 • 50 • h cm 3 = 44.95
g cm 3 h
BATCH FERMENTER Starting from an inoculum, Cxi at t = 0, and an initial quantity of limiting substrate Csi at t = 0, the biomass will grow after a short lag phase and will consume substrate. The growth rate slows as the substrate concentration decreases, and becomes zero when all the substrate has been consumed. Simultaneously, the biomass concentration initially increases slowly, then faster until it levels off when the substrate becomes depleted. Figure 11-21 shows a sketch of a batch fermenter. The mass balances for a constant volume zero feed batch fermentation are as follows: Using the generalized mass balance equation: 1 d(Vy) = V dt
∑ rgen − ∑ rcon + Dy i − γDy
where y is the general extensive property. The left side of Equation 11-56 becomes
(11-56)
Biochemical Reaction
885
Figure 11-21. The batch fermenter.
1 d(Vy) 1 dy dV = V +y V dt V dt dt For the batch reactor, u i = u O = 0,
(11-75)
dV =0 dt
Equation 11-56 becomes
dy = ∑ rgen − dt
∑ rcons
(11-76)
The equations for the state variables (viable cells, non-viable cells, substrate, and product) are: Viable cells:
dC xv = rx − rd dt
(11-77)
dC xd = rd dt
(11-78)
Non-viable cells:
886
Modeling of Chemical Kinetics and Reactor Design
(
dCs = − rsx + rsm + rsp dt
Substrate:
Product:
dC p dt
)
= rp
(11-79)
(11-80)
where rd = rate of cell deactivation (cell death), kg/m3•h rx = rate of cell growth, kg/m3•h rsx = rate of substrate consumption for biomass production, kg/m3•h rsm = rate of substrate consumption for maintenance formation, kg/m3•h rp = rate of product formation, kg/m3•h rsp = rate of substrate uptake for product formation, kg/m3•h The rate of these state variables can be further expressed as: Rate of cell growth: rx = µCxv
(11-81)
Rate of cell death: rd = kdCxv
(11-82)
From Leudeking-Piret kinetics [18], Rate of product formation: rp = αrx + βCxv
(11-83)
where α = growth-related product formation coefficient (kg product/ kg cells) β = non-growth related product formation coefficient (kg product/kg cells) Rate of substrate consumption for biomass production: rsx =
µ C xv rx = Yx′ s Yx′ s
(11-84)
Rate of substrate consumption for product formation: rsp =
rp Yp′ s
=
α µ C xv + βC xv Yp′ s
(11-85)
The rate of consumption of substrate to provide the energy for maintenance is:
Biochemical Reaction
887
Rate of substrate consumption for maintenance energy: rsm = msCxv
(11-86)
where ms is the rate constant (kg substrate/kg cells•h). The value of the maintenance energy coefficient, m, depends on the environmental conditions surrounding the cell and on its growth rate. Substituting the relationships into the material balances gives: Viable cells:
dC xv = µ C xv − k d C xv dt dC xd = k d C xv dt
Non-viable cells:
Substrate:
Product:
µ C xv α µ C xv + β C xv dCs = − + m sC xv + dt Yp′ s Yx′ s dC p dt
= α µ C xv + β C xv
(11-87) (11-88)
(11-89)
(11-90)
Including a set of initial conditions at the time of inoculation, the profiles of these variables with time can be determined by numerical integration with the aid of a computer program (Appendix D).
FED-BATCH REACTOR The fed batch reactor (FBR) is a reactor where fresh nutrients are added to replace those already used. The rate of the feed flow ui may be variable, and there is no outlet flowrate from the fermenter. As a consequence of feeding, the reactor volume changes with respect to time. Figure 11-22 illustrates a simple fed-batch reactor. The balance equations are: dV (11-91) For constant density and feed flowrate: = ui dt Substrate balance:
Biomass balance:
d(VCs ) = u i Csi + rs V dt d(VC x ) = rx V dt
(11-92)
(11-93)
888
Modeling of Chemical Kinetics and Reactor Design
Figure 11-22. The fed-batch reactor.
The quantities VCx and VCs represent the mass of biomass and substrate respectively in the reactor. Dividing these masses by the volume V gives the concentrations Cx and Cs as a function of time, which are required in the kinetic relationships to determine rx and rs. A quasi-steady state process is a fed-batch fermenter where dCx/dt = 0 and µ = u/V. Because V increases, µ therefore decreases, and thus the reactor moves through a series of changing steady states for which µ = D, during which Cs and µ decrease and Cx remains constant. Keller and Dunn [19] have provided a detailed analysis of fed-batch operation. An example of an industrial fed batch process is the production of penicillin by Penicillium chrysogenum. In this process, the cellular growth rate of the mycelium during the trophophase (i.e., cell production phase) is high, allowing this phase to be short. Correspondingly, the cellular growth rate during the idiophase (i.e., phase of product formation) is very low, and the emphasis in this phase is on the production of penicillin.
Biochemical Reaction
889
SCALE-UP OF BIOREACTORS Fermenters are generally designed to provide more oxygen (i.e., for a higher oxygen transfer rate OTR) than is required at the peak oxygen load of the organism. This usually occurs during the log or exponential growth phase. The oxygen uptake rate (OUR) value of a specific fermentation system is required to design the system, and these requirements are different for each microorganism. Employing the OTR criterion, a high respiration rate of the organism enables successful scale-up of aerobic processes. In such a case, the rate-limiting reaction step is the oxygen transfer resistance at the gasliquid interface. This can be increased when required by increasing the power as this transfers more oxygen from the gas phase to the liquid phase. Additionally, the back pressure or head pressure can increase the OTR while preventing foam production. Another essential scale-up parameter is k La, the mass transfer coefficient at the liquid-air interface. kLa is determined both by the terms “gassing-in” and “gassing-out,” respectively. The former is achieved by saturating the liquid in the vessel with oxygen. This involves measuring the time it takes to increase the oxygen concentration, which is measured with a dissolved oxygen (DO) probe. The latter technique uses nitrogen to purge the oxygen from the liquid. kLa can also be determined from a mass balance of the gas flow. If scale-up is relied on oxygen transfer alone, be careful not to oversize the fermenter. Scale-up of a batch reactor is reviewed in Chapter 13. The position of the agitator shaft and motor can affect scale-up of a fermenter. Generally, agitators and shafts are mounted in the top vertical position. However, the development of more reliable shaft seals has enabled the agitator to be mounted in the bottom position, thus increasing accessibility and ease of maintenance. This orientation now permits a shorter shaft, requires simpler physical support structures, creates head space for piping and a cyclone (which captures liquid-entrained gases), and reduces the vertical height requirement [13]. Figure 11-23 shows a piping and instrumentation diagram (P & ID) of a fermenter. An important factor in scale-up is to maintain constant tip speed (i.e., the speed at the end of the impeller is equal to the velocity in both the model and full-scale plant). If the speed is too high, it can lyse (i.e., kill) off the bacteria, and if the speed is too slow, the reactor contents will not be well mixed.
890
Modeling of Chemical Kinetics and Reactor Design
Figure 11-23. Piping and instrumentation diagram of a fermenter. (Source: Bartow [13], “Supersizing the aerobic fermenter,” Chemical Engineering, pp. 70–75, July 1999. Courtesy of Chemical Engineering.)
An algorithm for the scale-up of a fermenter is as follows [20]: 1. Choose a fermenter volume required based on the desired capacity. 2. Choose an impeller diameter, Di 3. Determine the reactor’s dimension (e.g., DT = tank diameter) based on geometric similarity, with the impeller diameter being the characteristic length. For example,
D T,full − scale D i,full − scale = D i,model D T,model 4. Calculate the impeller speed, N.
(πD i N)full − scale = (πD i N)model
(11-94)
Biochemical Reaction
N full − scale = N model •
D i,model D i,full − scale
891
(11-95)
5. Choose the mass transfer correlation for kLa (i.e., mass transfer coefficient of the air bubble). 6. Calculate the gas flowrate using the correlation and setting.
( k L a )full − scale = ( k L a )model Using the Perez and Sandall [21] correlation for non-Newtonian fluid D 2 Nρ k L a D 2i = 21.2 i D AB µe where DT Di DAB k La N Q Vs µd µe σ ρ
= = = = = = = = = = =
1.1
µe D AB
0.5
0.45 µ e Vs µ d σ µ e
0.7
(11-96)
tank diameter, m impeller diameter, m diffusivity, m2/s volumetric mass transfer coefficient, s–1 impeller rotational speed, s–1 volumetric flowrate, m3/s superficial gas velocity, (4Q/πDT2 ), m/s viscosity of dispersed phase, kg/m•s effective viscosity, kg/m•s surface tension, N/m density, kg/m3
Other relationships for determining kLa are given in Table 11-3. The mass transfer coefficient kLa depends on the following equipment parameters: 1.1 4Q 1 k L a ≈ 2 (D 2i N ) Di πD 2i
≈
D 0i .2
1.1
Q N 2 Di
0.45
0.45
(11-97)
892
Modeling of Chemical Kinetics and Reactor Design
Table 11-3 Mass transfer coefficients in fermenter 0.4
Coalescing media:
Pg k L a 20 = 0.026 • V
Non-coalescing media:
Pg k L a 20 = 0.0016 • V
In general:
Pg b k L a 20 = c • • ( v s ) V
In viscous fermentation broths:
Pg b −0.86 k L a = c • • ( v s ) • ( η) V
For coarse bubble systems:
k L a 20 = 0.32 • ( v s )
• (vs )
0.7
0.5
• (vs )
0.2
a
a
0.7
kLa20 = volumetric mass transfer at 20°C vs = superficial gas velocity η = dynamic viscosity
Vessel size (liters)
a
b
5 500 50,000
0.95 0.6 – 0.7 0.4 – 0.5
0.67 0.67 0.50
Source: Bartholomew, Adv. Appl. Microbiol., 2, 289, 1960.
( k L a )full − scale ( k L a )model
0.45 Q D 0i .2 N1.1 2 Di full − scale = =1 0.45 Q D 0i .2 N1.1 2 D i model
(11-98)
Therefore, 1 0.45
Q full − scale
0.2 1.1 D 2 − scale D i,model N model = Q model i,full 2 D i,model D i,full − scale N full − scale
7. Calculate the power requirement.
(11-99)
Biochemical Reaction
893
An alternative procedure for determining N and Q is to set either Q/ND = constant or Vs = constant, and then determine N from the power or mass transfer correlations. Table 11-4 gives the different scale-up criterion for the ratio of the full-scale and model for geometrically similar systems with volume of the model (Vm = 10 l) and the volume of the full-scale (Vfs = 10 m3). This gives a linear scale-up factor of 10. The table shows that different scale up criteria result in entirely different process conditions at production scale. For example, to give an equal power per unit volume (P/V) value involves an increase in the power input by 103. Correspondingly, for an equal value of stirrer speed (N), the power input (P) must be increased by a factor of 105. It may be necessary to find out how much the P/V ratio must be changed to achieve the same Reynolds number or how much larger the diameter of the stirrer must be if the stirrer speed is to be maintained. The first answer from Table 11-4 shows that the P/V ratio must be changed by 10–4, and the second answer shows that to use the same N, the value of ND must be increased by 102. Subsequently, the diameter would need to be increased by 102. Generally, a constant value of a particular operating/equipment variable is used. Some examples of scale-up based on constant operating variables as frequently used in fermentation are shown in Table 11-4. The properties, which can be kept constant at the different scales, are: • • • • •
P/V (for CSTR) kLa for (CSTR and bubble column) Vtip (for CSTR) Mixing times tm (for CSTR) A combination of P/V, Vtip, and the gas flowrate (for CSTR) Table 11-4 Different scale-up criteria and consequences Ratio of the value at 10 m3 relative to the value at 10 l
Scale-up criterion Equal Equal Equal Equal
P/V N (or tm–1) tip speed Reynolds number
P
P/V
N (or tm–1)
ND
NRe
10 3 10 5 10 2 0.1
1 102 0.1 10–4
0.22 1 0.1 0.01
2.15 102 1 0.1
21.5 10 2 10 1
P = power, V = volume, N = impeller speed, D = stirrer diameter, NRe = Reynolds number. Source: Biotechnology by Open Learning [22].
894
Modeling of Chemical Kinetics and Reactor Design
When P/V is used as the constant criterion, there is a decrease in power consumption under aerated conditions. In the literature many relationships exist, but in practice the gassed power consumption is about 50% of the ungassed power consumption. The correlations for gassed power consumption (Pg) and the ungassed power consumption (Ps) can be expressed by [22] −0.38 DT φg = 0.01312 • N −Fr0.16 • N 0Re.064 3 ND Ps Di
Pg
where NFr NRe N DT Di φg
= = = = = =
(11-100)
stirrer Froude number Reynolds number stirrer speed tank diameter impeller diameter volumetric gas flowrate
Other scale-up factors are mixing time, Reynolds number, and shear. Shear is maximum at the tip of the impeller and may be determined by Equation 11-101 [17]:
Smodel
D i,model = Sfull − scale D i, full − scale
13
(11-101)
An excessive shear can cause a breakup of some mycelial fermentation resulting in a low yield. A permissible tip speed is 2.5 to 5.0 m/s. Mixing time has been proposed as a scale-up consideration. Large-scale stirred tank reactors (with a volume larger than 5m3) are poorly mixed compared to small-scale reactors. This is a common cause of a change of regime (e.g., kinetic regime at model scale and transport regime at full-scale), which can present problems for mass and heat transfer involving viscous broths. The mixing time for aerated systems is expressed by [22] 0.6 (D T D i ) (H D T ) 3
Nt m =
{
3 N p (H i D i )
}
2 0.5
for N Re > 5 × 10 3
(11-102)
Biochemical Reaction
where Di DT N Np NRe H Hi tm
= = = = = = = =
895
impeller diameter tank diameter impeller speed impeller power number Reynolds number liquid height impeller height mixing time
Table 11-5 shows the mixing times for different sizes of reactors used in penicillin fermentation with H/DT = 2.5. The measured mixing time is compared with the calculated mixing time from Equation 11-102. The observed differences in the measured and calculated tm may be explained by the following: • When H/DT = 2.5, then tm increases more than the Equation 11-102 on the scaling from 1.4 m3—190 m3. • The viscosity of the broth can influence the mixing time. • Aerated conditions increase the mixing time. • There are different criteria for mixing (e.g., for being well mixed). Therefore, in scale-up, the use of the relationship to produce a larger system with the same tm using various configurations of Di, DT, H, Hi, and Np can result in an error. Hence, the use of equal mixing times
Table 11-5 Mixing times in different sizes of vessels
V(m3)
DT(m)
P(kW)
P/V (kW/m3)
tm(s) measured
tm(s) calculated from Equation 11-102
1.4 45.0 190.0
1.1 3.5 4.4
3.8 120.0 24.0
2.7 2.7 1.3
29 67 119
12 26 31
Source: Biotechnology by Open Learning [22].
896
Modeling of Chemical Kinetics and Reactor Design
as determined by theoretical considerations as the criterion for scaleup should be used with caution. Example 11-5
The antibiotic Tylosin was produced in a CSTR using Streptomyces fradiae in a 5 liter laboratory fermenter. For different substrate flowrates the concentrations of product and biomass were measured [23]. Flowrate (mL/h) Biomass conc. (g DW/L) Tylosin conc. (g/L)
50 39 0.7
100 29 0.4
150 28 0.2
200 22 0.1
350 17 0.01
DW = dry weight.
Determine the specific growth rate and the specific production rate, using the above experimental data. Solution
Assuming that the system is operating as steady state condition, the mass balance equation from Equation 11-39 becomes: Rate of input to control region = Rate of output from control region
Biochemical Reaction
897
The rate of input is the rate at which the product species is formed by the reaction. The rate of output is the rate at which a species leaves the system. Mass balance of biomass: VµCx = uCx
(11-103)
Mass balance of tylosin: VqCx = uCp
(11-104)
where µ and q are the specific growth and production rates, respectively. From Equations 11-103 and 11-104, µ and q are:
µ=
u V
and q =
(11-105) u Cp
(11-106)
VC x
Table 11-6 gives the results of µ and q for different substrate flowrates. Example 11-6
The growth of Mehylomonas L3 on methanol was observed in a CSTR. Working volume of the tank was V = 0.355 L. The concentration of methanol in fresh medium was 1 g/L. The results of the experiment at a steady state are given in the following table [24]. Flowrate (mL/h) 67 70 120 155 165 Biomass conc. (g DW/L) 0.441 0.47 0.527 0.563 0.563 Methanol conc. (mg/L) in output stream 30 20 23 16 7 DW = dry weight.
Table 11-6 Results of µ and q Flowrate (mL/h) µ(1/h) q × 103 (1/h)
50 0.01 0.212
100 0.02 0.276
150 0.03 0.214
200 0.04 0.182
350 0.07 0.041
898
Modeling of Chemical Kinetics and Reactor Design
Evaluate the Ys/X and the specific growth rate µ. Solution The mass balances for both biomass and substrate respectively are: Vµ C x = u C x
(11-107)
u Csi = u Cs + Vq C x
(11-108)
The specific growth rate and the yield coefficient are µ=
u V
(11-109)
and YS = X
(Csi − CS ) = Cx
q µ
(11-110)
Table 11-7 gives the results for the specific growth rate and the yield coefficient for varying flowrate.
NOMENCLATURE DT Di DAB N Q Vs
= = = = = =
tank diameter, m impeller diameter, m diffusivity, m2/s impeller rotational speed, s–1 volumetric flowrate, m3/s superficial gas velocity, (4Q/πD2T), m/s
Table 11-7 Results of µ and Ys/X Flowrate (mL/h) µ (1/h) Ys/X
67 0.189 2.2
70 0.197 2.13
120 0.338 1.85
155 0.437 1.75
165 0.465 1.76
Biochemical Reaction
µd µe σ ρ
= = = =
899
viscosity of dispersed phase, kg/m•s effective viscosity, kg/m•s surface tension, N/m density, kg/m3
GLOSSARY Activated sludge: Material containing a very large active microbial population used in the purification of waste water. Aerobe: Microorganism growing in the presence of air or requiring air for growth. Aerobic reactor: A reaction vessel operating under aerobic conditions with sterile air being used as the source of oxygen in dissolved state. Alcoholic (ethanolic) fermentation: A fermentation in which the major products are carbon dioxide and ethanol (alcohol). Algae: A group of photosynthetic organisms that range from microscopic size to a length of 20 m. They supply oxygen and consume nutrients in several different processes for biological waste treatment. Amino acids: The building blocks of proteins. There are twenty common ones; methionine, lysine, and trytophan are the ones produced in the greatest volume. Anaerobe: An organism that grows without air or requires oxygenfree conditions to live. Anaerobic reactor: A bioreactor in which no dissolved oxygen or nitrate is present and microbial activity is due to anaerobic bacteria. Antibiotic: A specific type of chemical substance that is administered to fight infections usually caused by bacteria, in humans or animals. Many antibiotics are produced by microorganisms; some are chemically synthesized. Antibody: A protein (immunoglobulin) produced by humans and higher animals in response to exposure to a specific antigen, and characterized by specific reactivity with its complementary antigen. Antigen: A substance, usually a protein or carbohydrate, which when introduced in the body of a human or higher animal, stimulates the production of an antibody that will react specifically with it.
900
Modeling of Chemical Kinetics and Reactor Design
Apparent viscosity: Ratio of shear stress to shear rate. It depends on the rate of shear. Aseptic: Free of infection. Assay: A technique that measures a specific biological response. Bacillus subtilis (B. Subtilis): An aerobic bacterium used as a host in rDNA experiments. Bacteria: Any of a large group of microscopic organisms having round, rod-like, spiral or filamentous, unicellular or non-cellular bodies that are often aggregated into colonies. Bacteria may exist as free living organisms in soil, water, or organic matter, or as parasites on the bodies of plants and animals. Batch processing: A processing technique in which a bioreactor is supplied with substrate and essential nutrients, sterilized and inoculated with microorganisms, and the process is run to completion followed by removal of products. Biocatalyst: An enzyme that plays a fundamental role in living organisms or in industry by activating or accelerating a bioprocess. Biochemical oxygen demand (BOD): The molecular oxygen used in meeting the metabolic needs of aerobic organisms in aqueous medium containing an oxidizable organic molecule. Biochemical pathway: A sequence of enzymatically catalyzed reactions occurring in a cell. Bioconversion: Chemical conversion of a naturally occurring biodegradable substance using a biocatalyst. Biodegradation: The breakdown of substances by microorganisms, mainly by aerobic bacteria. Biomass: All organic matters including those belonging to the aquatic environment that grow by the photosynthetic conversion of low energy carbon compounds employing solar energy. Biooxidation: Oxidation (loss of electrons) process accelerated by a biocatalyst. Biopolymers: Naturally occurring macromolecules that include proteins, nucleic acids, and polysaccharides.
Biochemical Reaction
901
Bioprocess: The process that uses complete living cells or their components (e.g., enzymes, organelles, and chloroplasts) to effect desired chemical and/or physical changes. Bioreactor: The vessel of defined configuration in which a bioprocess is carried out. Biosensor: An electronic device that transforms signals produced by biological molecules to detect concentration or transport of specific compounds. Biosynthesis: Production, by synthesis or degradation, of a chemical compound by living organism, plant or animal cells, or enzymes elaborated by them. Biotechnology: Commercial processes that use living organisms, or substances from those organisms, to make or modify a product. This includes techniques used for improving the characteristics of economically important plants and animals and for the development of microorganisms to act on the environment. Broth: Complex fluid mixture in bioreactor, including cells, nutrients, substrate, antifoam, cell products, etc. Catalase: An enzyme that catalyses the breakdown of hydrogen peroxide to water and oxygen. Catalysis: A process by which the rate of a chemical reaction is increased by a substance (namely enzymes in biochemical reactions) that remains chemically unchanged at the end of the reaction. Cell: The smallest structural unit of living matter capable of functioning independently; it is a microscopic mass of protoplasm surrounded by a semipermeable membrane, including one or more nuclei and various non-living substances that are capable, either alone or with other cells, of performing all the fundamental functions of life. Cell culture: The in vitro growth of cells isolated from multicellular organisms. These cells are usually of one type. Cellulase: The enzyme that cuts the linear chain of cellulose, a glucose polymer at 1-4-β-linkages into cellodextrins and glucose. Cellulose: A polymer of six-carbon glucose sugars found in all plant matter; the most abundant biological substance on earth.
902
Modeling of Chemical Kinetics and Reactor Design
Chemical oxygen demand (COD): A measure of the amount of oxygen, expressed in milligrams per liter, required to oxidize organic matter present in a substance using a chemical oxidation method. Chemostat: A bioreactor in which steady-state growth of microorganisms is maintained over prolonged periods of time under sterile conditions by providing the cells with constant input of nutrients and continuously removing effluent with cells as output. Clone: A group of genetically identical cells or organisms produced asexually from a common ancestor. Colony: A visible accumulation of cells that usually arises from the growth of a single microorganism. Continuous culture: A method of cultivation in which nutrients are supplied and products are removed continuously at volumetrically equal rates maintaining the cells in a condition of stable multiplication and growth. Culture: A population of microorganisms. Denitrification: The reduction of nitrates to nitrites and finally to nitrous oxide or even to molecular nitrogen catalyzed by facultative aerobic soil bacteria working under anaerobic conditions. Deoxyribonucleic acid (DNA): A linear polymer, made up of deoxyribonucleotide units, that is the carrier of genetic information, present in chromosomes and chromosomal material of cell orgenelles such as mitrochondria and chloroplasts, and also in some viruses. Every characteristic inherited trait has its origin in the code of each individual’s DNA. Dextran: Any of several polysaccharides that yield only glucose on hydrolysis. Dilution rate: A measure of the rate at which the existing medium in continuous cultivation of organisms is replaced with fresh medium. Diffusion: The net movement of molecules or ions from an area of higher concentration to an area of lower concentration. Enzyme: A protein that functions as a biocatalyst in a chemical reaction. Any group of catalytic proteins that are produced by living cells mediating and promoting the chemical processes of life without
Biochemical Reaction
903
themselves being altered or destroyed. This includes proteases, glucoamylase, alpha amylase, glucose isomerase, and rennin. Escherichia coli (E. coli): A species of bacteria that inhabits the intestinal tract of most vertebrates. Many non-pathogenic strains are used experimentally as hosts for rDNA. Exponential growth: The phase of cell growth in which the number of cells or the cell mass increases exponentially. Facultative: The ability to live under more than one set of conditions, usually in relation to oxygen tension prevailing in the medium, that is aerobic or anaerobic (e.g., facultative anerobes). Fatty acids: Organic acids with long carbon chains. Fatty acids are abundant in cell membranes and are widely used as emulsifiers, as metallic soaps, and for other industrial uses. Fed-batch culture: A cell cultivation technique in which one or more nutrients are supplied to the bioreactor in a given sequence during the growth or bioconversion process while the products remain in the vessel until the end of the run. Fermentation: An anaerobic bioprocess. An enzymatic transformation of organic substrates, especially carbohydrates, generally accompanied by the evolution of gas as a byproduct. Fermentation is used in various industrial processes for the manufacture of products (e.g., alcohols, organic acids, solvents, and cheese) by the addition of yeasts, moulds, and bacteria. Fermenter: An industrial microbiological reactor in which the addition of nutrients, removal of products, and insertion of measuring sensors and control devices are maintained while accessories like heating, aeration, agitation, and sterilization systems are provided. Flocculation: Agglomeration of colloidal material by adding a chemical that causes the colloidal particles to produce larger particles. Fungi: Simple vegetative bodies from which reproductive structures are elaborated. The fungi contain no chlorophyll and therefore require sources of complex organic molecules. Many species grow on dead organic materials and others live as parasites. Gene: The basic unit of inheritance; a sequence of DNA coding that can be translated by the cell machinery into a sequence of amino acids linked to form a protein.
904
Modeling of Chemical Kinetics and Reactor Design
Glucose: A 6-carbon sugar molecule, which is the building block of natural substances like cellulose, starch, dextrans, xanthan, and some other biopolymers and used as a basic energy source by the cells of most organisms. Glycolysis: Metabolic pathway involving the conversion of glucose to lactic acid or ethanol. Growth curve: Graphical representation of the growth of an organism in nutrient medium in a batch reactor under predetermined environmental conditions. Immobilized cell: Technique used for the fixation of enzymes or cells onto a solid support. Incubation: The introduction of microorganisms into a culture medium with a view to growing a large number of identical cells all by propagation. Inhibition: The decrease of the rate of an enzyme-catalyzed reaction by a chemical compound including substrate analogues. Such inhibition may be competitive with the substrate (binding at the active site of the enzyme) or non-competitive (binding at an allosteric site). Inhibitor: An agent that prevents the normal action of an enzyme without destroying it (e.g., a substance (inhibitor) B causes the slowdown of the enzyme-substrate reaction of A → R). Inoculum: A batch fermentation that starts with an initial charge of cells. Lineweaver-Burk plot: Method of analyzing kinetic data (growth rates of enzyme catalyzed reactions) in linear form using a double reciprocal plot of rate versus substrate concentration. Lipid: A large, varied class of water insoluble organic molecules, including steriods, fatty acids, prostaglandins, terpenes, and waxes. Log phase: Period of bacterial growth with logarithmic increase in cell number. Mass transfer: Irreversible and spontaneous transport of mass of a chemical component in a space with a non-homogeneous field of the chemical potential of the component. The driving force causing the transport can be the difference in concentration (in liquids) or partial pressures ( in gases) of the component. In biological systems,
Biochemical Reaction
905
mass transfer may result from diffusion facilitated transport or active transport. Maximum oxygen transfer rate: Volumetric mass transfer coefficient times the oxygen solubility at constant temperature and pressure. The value, which is often obtained by the sulfite method, wrongly though, has been used in the past for the evaluation of oxygen transfer rate of a chemical reaction as a rough approximation. For bioreactor systems, gassing out dynamic methods and oxygen sensors are employed. Medium: Mixture of nutrient substances required by cells for growth and metabolism. Metabolism: The total of all chemical reaction activities in a living organism producing energy and growth. Michaelis-Menten kinetics: Kinetics of conversion of substrates in enzyme-catalyzed reactions. Microorganisms: Microscopic living entities, viruses, bacteria, and yeasts. Mixed culture: Two or more species of microorganisms living in the same medium. Moulds: Multi-cellular filaments that increase by vegetative growth of the filament. Monod kinetics: Kinetics of microbial cell growth as a function of substrate concentration proposed by Jacques Monod and widely used to understand growth-substrate relationships. Mycelium: A mass of filaments composing the vegetative body of many fungi and some bacteria. Nutrient: A substance used as food. Oxygen transfer rate (OTR): The product of volumetric oxygen transfer rate kLa and the oxygen concentration driving force (C* – CL), (ML–3T–1), where kL is the mass transfer coefficient based on liquid phase resistance to mass transfer (LT–1), a is the air bubble surface area per unit volume (L–1), and C* and CL are oxygen solubility and dissolved oxygen concentration, respectively. All the terms of OTR refer to the time average values of a dynamic situation. Oxygen uptake rate (OUR): The actual rate at which oxygen utilization takes place and is given by (µ/YO2) Cx, where µ is specific growth
906
Modeling of Chemical Kinetics and Reactor Design
rate of the concerned cells, h–1, YO2 is the oxygen uptake per unit cell gg–1, and Cx is the concentration of cells, gml–1. Organism: A living biological specimen. Pasteurization: The process of mild heating to kill particular spoilage organisms or pathogens. Pathogen: A disease producing agent. The term is usually restricted to a living organism such as a bacterium or virus. Peptide: A linear polymer of amino acids. A polymer of numerous amino acids is called a polypeptide. Peroxidase: An enzyme that breaks down the hydrogen peroxide, H2O2 + NADH + H+ → 2H2O + NAD+. pH: A measure of the acidity or basicity of a solution on a scale of 0 (acidic) to 14 (basic) [e.g., lemon juice has a pH of 2.2 (acidic), water has a pH of 7.0 (neutral), and a solution of baking soda has a pH of 8.5 (basic)]. Protease: Protein digesting enzyme. Protein: One or more polypeptides assembled in biologically active units; proteins function as catalysts in metabolism and as structural elements of cells in tissues. Pure culture: A culture containing only one species of microorganism. Recombinant: DNA (r-DNA): The hybrid DNA produced by joining pieces of DNA from different organisms together in vitro (i.e., in an artificial apparatus). Ribonucleic acid (RNA): A nucleic acid that contains the sugar ribose. Single cell protein: Cells, or protein extracts, of microorganisms grown in large quantities for use as human or animal protein supplements. Sludge: Precipitated mechanically or biologically separated solid matter produced during water and or sewage treatment or industrial processes. Such solids may be amenable to biological control. Species: One kind of microorganism. Specific enzyme activity: Amount of substrate rendered into product per unit dry weight of enzyme protein per unit time.
Biochemical Reaction
907
Specific growth rate coefficient, µ: The rate of change of microbial cell mass concentration per unit cell concentration: µ = (1/C x)(dCx/dt) (where Cx = cell mass concentration, g/l). Spore: A uni- or multicellular, asexual, reproductive, or resting body that is resistant to unfavorable environmental conditions, and which produces a new vegetative individual when the environment is favorable. Sporulation: The germination of a spore by a bacterium or by a yeast. Starch: A polymeric substance of glucose molecules and a component of many terrestrial and aquatic plants used by some organisms as a means of energy storage: starch is broken down by enzymes (amylases) to yield glucose, which can be used as a feedstock for chemical or energy production. Steriods: A group of organic compounds, some of which act as hormones to stimulate cell growth in higher animals and humans. Substrate: A chemical substance acted upon by an enzyme or a cell to give rise to a product. Taxonomy: Classification of organisms. Thixotropic fluid: A fluid when subjected to a constant shear stress exhibits an apparent viscosity that increases with time. Total organic carbon (TOC): The total amount of organic carbon in a mixture. Total oxygen demand (TOD): The total amount of molecular oxygen consumed in the combustion of oxygen-demanding substances at about 900°C. Toxicity: The ability of a substance to produce a harmful effect on an organism by physical contact, ingestion, or inhalation. Toxin: A substance produced in some cases by disease-causing microorganisms, which is toxic to other living cells. Vaccine: A suspension of attenuated or killed bacteria or virus, or portions thereof, injected to produce active immunity. Vegetative cell: Cells involved with obtaining nutrients, as opposed to reproduction or resting. Volumetric mass transfer coefficient, kLa: The proportionality coefficient reflecting both molecular diffusion, turbulent mass transfer, and specific area for mass transfer.
908
Modeling of Chemical Kinetics and Reactor Design
Virus: Any of a large group of submicroscopic agents infecting plants, animals, and bacteria, and unable to reproduce outside the tissue of the host. A fully formed virus consists of nucleic acid (DNA or RNA) surrounded by a protein, or protein and lipid coat. Vitamin: An organic compound present in variable, minute quantities in natural foodstuffs, and essential for the normal processes of growth and maintenance of the body. Vitamins do not furnish energy, but are necessary for energy transformation and for regulation of metabolism. Yeast: A fungus of the family Saccharomycetaceae that is used especially in the making of alcoholic liquors and as leavening in baking, and also in various bioprocesses.
REFERENCES 1. Walas, S. M., Chemical Reaction Engineering Handbook of Solved Problems, Gordon & Breach Publishers, 1995. 2. Bailey, J. E. and Ollis, D. F., Biochemical Engineering Fundamentals, 2nd ed., Mc.Graw-Hill Book Co., 1986. 3. Bungay, H. R., Computer Games and Simulation for Biochemical Engineering, John Wiley & Sons, 1985. 4. Sinclair, C. G. and Kristiansen, B., Fermentation Kinetics and Modelling, J. D. Bu’Lock (Ed.) Open University Press 1987. 5. Volesky, B. and Votruba, J., Modeling and Optimization of Fermentation Processes, Elsevier, 1992. 6. Ingham, J., et al., Chemical Engineering Dynamics—An Introduction to Modelling and Computer Simulation, 2nd ed., WileyVCH Verlag GmbH, 2000. 7. Michaelis, L. and Menten, M. L., Biochem. Z., 49, 333, 1913. 8. Briggs, G. E. and Haldane, J. B. S., Brochem, J., 19, 338, 1925. 9. Putman, S. J., et al., Biochem J., 129, 301, 1972. 10. Missen, R. W., et al., Introduction to Chemical Reaction Engineering and Kinetics, John Wiley & Sons, 1999. 11. Schügerl, K. J., “New bioreactors for aerobic processes,” Int. Chem. Eng., 22, 591, 1982. 12. Aiba, S., Humphrey, A. E., and Mills, N. F., Biochemical Engineering, 2nd ed., University of Tokyo Press, Tokyo, 1973. 13. Bartow, M. V., “Supersizing the aerobic fermenter,” Chemical Engineering, pp. 70–75, 1999.
Biochemical Reaction
909
14. Rai, V. R. and Constantinide, A., “Mathematical modeling and optimization of the gluconic acid fermentation,” AIChE Symp. Ser., Vol. 69, No. 132, p. 114, 1973. 15. Marquadt, D. W., “An algorithm for least-squares estimation of non-linear parameters,” J. Soc. Indust. Appl. Math., 11, 431, 1963. 16. Roberts, R. S., et al., “The effect of agitation on oxygen mass transfer in a fermenter,” Chem. Eng., Ed., 26, 142, 1992. 17. Perry, R. H. and Green, D. W., Perry’s Chemical Engineers’ Handbook, 7th ed., McGraw-Hill Book Co., 1999. 18. Leudeking, R. and Piret, E. L., “A kinetic study of the lactic acid fermentation,” J. Biochem. Microbiol, Technol. Eng., 1: 393, 1959. 19. Keller, R. and Dunn, I. J., “Computer simulation of the biomass production rate of cyclic fed batch continuous culture,” J. Appl. Chem., Biotechnol., 28, 508–514, 1978. 20. Fogler, H. S., Elements of Chemical Reaction Engineering, 3rd ed., Prentice Hall Int. Series, 1999. 21. Perez, J. F. and Sandall, O. C., AIChE J., 20, 770, 1974. 22. Biotechnology by Open Learning, Bioreactor Design and Product Yield, Butterworth-Heinemann, ISBN 07506-15095, 1992. 23. Gray, P. P. and Bhuwapathanapun, S., Biotechnol. Bioeng., 22: 1785, 1980. 24. Hirt, W., Biotechnol. Bioeng., 23, 235, 1981.
910
Modeling of Chemical Kinetics and Reactor Design
CHAPTER TWELVE
Safety in Chemical Reaction Engineering INTRODUCTION In the chemical process industries (CPI), chemical manufacture, especially in the fine, pharmaceutical, and speciality chemical industries, involves the processing of reactive chemicals, toxic or flammable liquids, vapors, gases, and powders. Although the safety records of these industries have improved in recent years, fires, explosions, and incidents involving hazardous chemical reactions still occur. A basis for good engineering practice in assessing chemical reaction hazards is essential, with the goal to help designers, engineers, and scientists responsible for testing and operating chemical plants meet the statutory duties of safety imposed by governmental organizations [e.g., Environmental Protection Agency (EPA), Occupational Safety and Health Administration (OSHA), USA, Health & Safety Executive, UK]. The control of chemical reactions (e.g., esterification, sulfonation, nitration, alkylation, polymerization, oxidation, reduction, halogenation) and associated hazards are an essential aspect of chemical manufacture in the CPI. The industries manufacture nearly all their products, such as inorganic, organic, agricultural, polymers, and pharmaceuticals, through the control of reactive chemicals. The reactions that occur are generally without incident. Barton and Nolan [1] examined exothermic runaway incidents and found that the principal causes were: • • • • • •
Inadequate temperature control Inadequate agitation Inadequate maintenance Raw material quality Little or no study of the reaction chemistry and thermochemistry Human factors 910
Safety in Chemical Reaction Engineering
911
Other factors that are responsible for exothermic incidents are: • Poor understanding of the reaction chemistry resulting in a poorly designed plant. • Underrated control and safety backup systems. • Inadequate procedures and training.
HAZARD EVALUATION IN THE CHEMICAL PROCESS INDUSTRIES The safe design and operation of chemical processing equipment requires detailed attention to the hazards inherent in certain chemicals and processes. Chemical plant hazards can occur from many sources. Principal hazards arise from: • Fire and explosion hazards. • Thermal instability of reactants, reactant mixtures, isolated intermediates, and products. • Rapid gas evolution that can pressurize and possibly rupture the plant. • Rapid exothermic reaction, which can raise the temperature or cause violent boiling of the reactants and also lead to pressurization. Earlier reviews have been concerned with energy relationships for a particular chemical process, which are based on two general classifications of chemical processes, conventional and hazardous ( 2) . The former is used to describe a non-explosive, non-flammable reaction and the latter to describe an explosive and flammable reaction. The division of reactions does not account for the varying degree of safety or hazards of a particular reaction, which may lie between these extremes, and consequently becomes too limiting in the design. Safety is most likely to be neglected with conventional reactions while over design may be expected with hazardous reactions. These limitations can be avoided by introducing a third class of reactions, called “special,” that covers the intermediate area between conventional and hazardous where reactions are relatively safe. Shabica [2] has proposed some guidelines for this third classification and Figure 12-1 shows the increasing degree of hazard of a particular process. The Appendix at the end of this chapter lists hazard ratings of chemical reactions and
912
Modeling of Chemical Kinetics and Reactor Design
Figure 12-1. The increasing degree of hazard of matter plotted against the increasing hazard of a process. (Source: Shabica [2].)
substances for the three classifications. Figures 12-2, 12-3, and 12-4 show the flowsheets and floor plans of the hazardous, special, and conventional equipment. Chemical reaction hazards must be considered in assessing whether a process can be operated safely on the manufacturing scale. Furthermore, the effect of scale-up is particularly important. A reaction, which is innocuous on the laboratory or pilot plant scale, can be disastrous in a full-scale manufacturing plant. For example, the heat release from a highly exothermic process, such as the reduction of an aromatic nitro compound, can be easily controlled in laboratory glassware. However,
Safety in Chemical Reaction Engineering
913
Figure 12-2. Flowsheet and floor plan of hazardous equipment. (Source: Shabica [2].)
914
Modeling of Chemical Kinetics and Reactor Design
Figure 12-3. Flowsheet and floor plan of special equipment. (Source: Shabica [2].)
if the same reaction is performed in a full-scale plant reactor with a smaller surface area to volume ratio, efficient cooling is essential. Otherwise, a thermal runaway and violent decomposition may occur. Similarly, a large quantity of gas produced by the sudden decomposition of a diazonium compound can be easily vented on the laboratory
Safety in Chemical Reaction Engineering
915
Figure 12-4. Flowsheet and floor plan of conventional equipment. (Source: Shabica [2].)
scale, but the same decomposition on a large scale could pressurize and rupture a full-scale plant. Additionally, consequences of possible process maloperations, such as incorrect charging sequence, contamination of reactants, agitation failure and poor temperature control, adding reactants too quickly,
916
Modeling of Chemical Kinetics and Reactor Design
omitting one of the reactants, and incorrect reactant concentration (recycling) must be considered. A number of parameters govern the reaction hazards associated with a process. These include the following: • • • • • • • • •
Chemical components Process temperature Process pressure Thermochemical characteristics of the reaction Reaction rate Reaction ratios Solvent effects Batch size Operational procedure
The assessment of the hazards of a particular process requires investigating the effects of these parameters through experimental work, interpretating the results in relation to the plant situation, and defining a suitable basis for safe operation.
HAZARD ASSESSMENT PROCEDURES Hazard assessments are essential and should be performed on all chemical processes. The reactors such as batch, semi-batch, and continuous as reviewed in Chapter 4, can be used for performing various operations. Many industrial reactions are exothermic (i.e., accompanied by the evolution of heat) and, therefore, overheating can occur. In batch operations, all the reactants are added to the reactor at the start of the reaction. In semi-batch operations, one or more of the reactants are charged to the reactor in the beginning, and others are then metered in, giving some control over the reaction rate and, thus, the rate of heat production. Overheating often results in thermal runaway, which is characterized by progressive increases in the rate of heat generation, and, hence, temperature and pressure. Thermal runaway is a particular problem in unsteady state batch reactions, where the rate of reaction and, therefore, the rate of heat production varies with time. The consequences of thermal runaway are sometimes severe as in the incidents at Seveso [3]. In this case, a bursting disk ruptured on a reactor. The reactor was used to manufacture trichlorophenol at a temperature of 170–185°C and was heated
Safety in Chemical Reaction Engineering
917
by steam at 190°C. The batch was dehydrated and left at a temperature of 158°C over the weekend. Ethylene glycol and caustic soda give exothermic secondary reactions producing sodium polyglycolates, sodium oxalate, sodium carbonate, and hydrogen, thus exhibiting an autocatalytic behavior. These reactions caused a temperature rise allowing the production of tetrachlorodioxin and the subsequent vessel pressurization. The Bhopal fatal incident [4] (not a thermal runaway) involved a toxic release of an intermediate, methyl isocyanate (MIC), which resulted in over 2,000 deaths. A runaway polymerization of highly toxic methyl isocyanate occurred in a storage tank. The runaway polymerization caused an uncontrolled pressure rise, which caused a relief valve to lift and discharge a plume of toxic vapor over the city. The task of specifying the design, operation, and control of a reactor with stirrer, heating, or cooling coils, reflux facilities, and emergency relief venting can pose a problem if all the time-dependent parameters are not considered. The use of batch processing techniques in the fine chemical industry is often characterized by: • • • •
Multi-product plant (must have adaptable safety system) Complex developing chemistry High frequency of change Process control is simpler than continuous processes
These factors are attributed to batch and semi-batch processes rather than continuous processes. However, the use of continuous processes on fine chemical manufacturing sites is limited. It is often preferable to use the semi-batch mode as opposed to batch processes. The Appendix lists hazards of pertinent chemical reactions for toxic and reactive hazards chemicals. Information concerning the safety of various chemicals (e.g., ammonia and others) can be readily obtained from the World Wide Web. Table 12-1 shows how to access a material safety data sheet at the Vermont Safety Information (VIRI) site on the Internet. EXOTHERMS Temperature-induced runaways have many causes including loss of cooling, loss of agitation, and excessive heating. During a temperature-
918
Modeling of Chemical Kinetics and Reactor Design
Table 12-1 Accessing a material safety data sheet (MSDS) 1. Type in http://www.siri.org/. 2. When the first screen appears, click on SIRI MSDS collection-Vermont site. 3. When the first page appears, type in the chemical you want in the find box. Example: Find ammonia Then click on search 4. The next page shows a list of companies that provide data on ammonia. Example: Mallinckrodt Baker—Ammonia Solution Strong Mallinckrodt Baker—Ammonia Aqueous 5. Scroll through “Ammonia Solution, Strong” for the required information: Product Identification Composition/Information on Ingredients Hazards Identification First Aid Measures Fire Fighting Measures Accidental Release Measures Handling and Storage Exposure Controls/Personal Protection Physical and Chemical Properties Stability and Reactivity Toxicological Information Ecological Information Disposal Considerations Transport Information Regulatory Information Other Information
induced upset, the reactor temperature rises above the normal operating target. When any of the temperature elements senses a high reactor temperature, the programmable logic controller (PLC) software shutdown system automatically puts the reactor on idle (isolates). This action doubles the cooling water flow to the reactor by opening a bypass valve. If these reactions are unsuccessful in terminating the temperature rise, the shut-down system opens the quench valves, dumping the reaction mass into the water-filled quench tank. If the dump valves fail to operate, the reactor contents soon reach a temperature where a violent self-accelerating decomposition occurs. The
Safety in Chemical Reaction Engineering
919
uncontrolled exotherm generates a large volume of gas and ejects the process material out of the reactor into the containment pot. ACCUMULATION It is important to know how much heat of reaction can accumulate when assessing the hazards related to an exothermic reaction. Accumulation in a batch or semi-batch process can be the result of: • • • • •
Adding a reactant too quickly Loss of agitation Performing the reaction at too low a temperature Inhibition of the reaction Delayed initiation of the desired reaction
Reactants can accumulate when the chosen reaction temperature is too low, and as such the reaction continues even after the end of the addition. In such a case, a hazardous situation could occur if cooling were lost as exemplified by Barton and Rogers [5]. Impurities or the delayed addition of a catalyst causes inhibition or delayed initiation resulting in accumulation in the reactors. The major hazard from accumulation of the reactants is due to a potentially rapid reaction and consequent high heat output that occurs when the reaction finally starts. If the heat output is greater than the cooling capacity of the plant, the reaction will run away. The reaction might commence if an agitator is restarted after it has stopped, a catalyst is added suddenly, or because the desired reaction is slow to start.
THERMAL RUNAWAY CHEMICAL REACTION HAZARDS Thermal runaway reactions are the results of chemical reactions in batch or semi-batch reactors. A thermal runaway commences when the heat generated by a chemical reaction exceeds the heat that can be removed to the surroundings as shown in Figure 12-5. The surplus heat increases the temperature of the reaction mass, which causes the reaction rate to increase, and subsequently accelerates the rate of heat production. Thermal runaway occurs as follows: as the temperature rises, the rate of heat loss to the surroundings increases approximately linearly with temperature. However, the rate of reaction, and thus the
920
Modeling of Chemical Kinetics and Reactor Design
Figure 12-5. A typical curve of heat rate versus temperature.
rate of heat generation, increases exponentially. If the energy release is large enough, high vapor pressures may result or gaseous products may be formed, which can lead to over-pressurization and possible mechanical destruction of the reactor or vessel (thermal explosion). The released energy might result from the wanted reaction or from the reaction mass if the materials involved are thermodynamically unstable. The accumulation of the starting materials or intermediate products is an initial stage of a runaway reaction. Figure 12-6 illustrates the common causes of reactant accumulation. The energy release with the reactant accumulation can cause the batch temperature to rise to a critical level thereby triggering the secondary (unwanted) reactions. Thermal runaway starts slowly and then accelerates until finally it may lead to an explosion.
THE φ-FACTOR The fraction of heat required to heat up the vessel, rather than its contents, depends on the heat capacity of the vessel (i.e., how much
Figure 12-6. Causes of runaways in industrial reactors. (Source: W. Regenass, “Safe Operation of Exothermic Reactions,” Internal Ciba-Geigy Publication, 1984.)
Safety in Chemical Reaction Engineering 921
922
Modeling of Chemical Kinetics and Reactor Design
energy is required to raise the temperature of the vessel with respect to the reaction mass). The heat loss to the vessel is known as the φ-factor [6]. The φ-factor is the ratio of the total heat capacity of the sample and vessel to that of the sample alone, and is defined by φ=
M sC ps (sample) + M v C pv ( vessel)
where Ms Cps Mv Cpv
M sC ps (sample)
= = = =
mass of specific mass of specific
(12-1)
the sample (kg) heat capacity of sample (J/kg•K) the vessel (kg) heat capacity of vessel (J/kg•K)
The φ-factor does not account for the heat loss to the environment. It is used to adjust the self-heating rates as well as the observed adiabatic temperature rise. As the scale of operation increases, the effect of the heat consumption by the plant typically declines. Therefore, the extent to which the kinetics of the runaway reaction is influenced by the plant is reduced. For plant scale vessels, the φ-factor is usually low (i.e., 1.0–1.2) depending on the heat capacity of the sample and the vessel fill ratio. Laboratory testing for vent sizing must simulate these low φ-factors. If the laboratory φ-factor is high, several anomalies will occur: • The rate of reaction will be reduced (i.e., giving incorrect reaction rate data for vent sizing). • The magnitude of the exotherm will be smaller by a factor of φ. • Measured pressure effects will be smaller than those that would occur on the plant. • The induction period of a thermal runaway reaction will be increased compared to the plant. The consequences of these erroneous anomalies are: • Inadequate safety design system. • Undersized emergency relief system. • Unknown decompositions may occur at elevated temperatures, which may not be realized in the laboratory.
Safety in Chemical Reaction Engineering
923
ONSET TEMPERATURE The reaction onset temperature is the temperature where it is assumed significant fuel consumption begins. The onset temperature is expressed by [7] Tonset =
where B = A= B C EA R
= = = = Tonset = xo = ∆HRx = φ = • Tex =
B x ∆H • A ln o Rx • C • φ • Tex
(12-2)
EA (12-3) R rate constant (pre-exponential factor from Arrhenius equation k = A exp (–EA/RT), sec–1 (i.e., for a first order reaction) reduced activation energy, K liquid heat capacity of the product (J/kg•K) activation energy, J/mol gas constant (8.314 J/mol•K) onset temperature, K initial mass fraction heat of decomposition, J/kg dimensionless thermal inertial factor for the sample holder or product container (φ-factor) bulk heat-up rate driven by an external heat source, °C/sec
TIME-TO-MAXIMUM RATE An onset temperature can be selected based on an arbitrary timeto-maximum-rate from the relation
t mr =
C • φ • T 2 exp(B Tonset ) x o • ∆H Rx • A • B
(12-4)
Rearranging Equation 12-4 yields Tonset =
B t • x • ∆H Rx • A • B ln mr o C • φ • T2
(12-5)
924
Modeling of Chemical Kinetics and Reactor Design
Equation 12-5 gives an onset temperature Tonset that corresponds to a time-to-maximum rate tmr (min) using a successive substitution solution procedure. An initial guess of T = 350 K for the right side of Equation 12-5 will give a solution value of Tonset on the left side of Equation 12-5 within 1% or on an absolute basis ±3°C. Convergence is reached within several successive substitution iterations. MAXIMUM REACTION TEMPERATURE Once the onset temperature is determined, it is then possible to obtain the maximum reaction temperature by the adiabatic temperature rise and any contribution due to external heat input. The theoretical adiabatic temperature increase is ∆Tadia =
x o • ∆H Rx C•φ
(12-6)
The contribution to the overall temperature increase from external heat input is defined by
∆Tex =
• • t mr Tex 2
(12-7)
where ∆T ex = temperature increase attributed to external heating effects,°C • = bulk heat-up rate due to external heating alone, °C/min Tex tmr = time-to-maximum rate as determined by Equation 12-5 with tempertaure T set equal to Tonset, min From these expressions, the maximum reaction temperature Tmax is defined by Tmax = Tonset + ∆Tadia + ∆Tex
(12-8)
METHODS FOR SCREENING THERMAL RUNAWAY CONDITIONS Various techniques have been employed for testing and screening hazardous compounds produced in the CPI. The results obtained from these instruments assist the designers and technologists in scale-up of the plants. The suitability of the various instruments and test methods
Safety in Chemical Reaction Engineering
925
are illustrated in Figure 12-7. From this figure, it can be inferred that not all the techniques can provide all the answers in different temperature versus time regimes. The evaluation of chemical reaction hazards involves establishing exothermic activity and/or gas evolution that could give rise to incidents. However, such evaluation cannot be carried out in isolation or by some simple sequence of testing. The techniques employed and the results obtained need to simulate large-scale plant behavior. Adiabatic calorimeters can be used to measure the temperature time curve of selfheating and the induction time of thermal explosions. The pertinent experimental parameters, which allow the data to be determined under specified conditions, can be used to simulate plant situations.
Figure 12-7. Simplified scenario of a thermal runaway. (Source: T. Hoppe and B. Grob, “Heat flow calorimetry as a testing method for preventing runaway reactions,” Int. Symp. on Runaway Reactions, CCPS, AIChE, March 7–9, 1989.)
926
Modeling of Chemical Kinetics and Reactor Design
Adiabatic reaction calorimetry has proven to be a successful tool for assessing thermal hazards of reactive chemicals, generating thermodynamic data, and optimizing process design for maximizing safety. It is not only used for screening [8], but also for obtaining kinetic and thermodynamic data [9,10]. The results are used for constructing computer models of chemical processes that may undergo a thermal runaway reaction. Figures 12-8a, b, c, and d show plots of various parameters for an adiabatic system. The various proprietory adiabatic calorimeters and vent sizing instruments used in laboratory investigations or for scale-up of vessels in the CPI are reviewed below.
TEST INSTRUMENTS ACCELERATING RATE CALORIMETER (ARC™) The accelerating rate calorimeter (ARC™) is an instrument that measures the temperature, temperature rate, and pressure changes of a reaction sample as a function of time under adiabatic “runaway” conditions. The ARC provides data pertaining to thermochemistry and kinetics. The ARC is used to assess thermal stability (e.g., for safe storage and to detect undesirable secondary reactions), gather total heat release and heat release rate data (to prevent thermal runaways), measure pressure, and pressure rate data due to gas release (to prevent vessel rupture and for the design of emergency relief and mitigation systems). In the ARC (Figure 12-9), the sample of approximately 5 g or 4 ml is placed in a one-inch diameter metal sphere (bomb) and situated in a heated oven under adiabatic conditions. These conditions are achieved by heating the chamber surrounding the bomb to the same temperature as the bomb. The thermocouple attached to the sample bomb is used to measure the sample temperature. A heat-wait-search mode of operation is used to detect an exotherm. If the temperature of the bomb increases due to an exotherm, the temperature of the surrounding chamber increases accordingly. The rate of temperature increase (selfheat rate) and bomb pressure are also tracked. Adiabatic conditions of the sample and the bomb are both maintained for self-heat rates up to 10°C/min. If the self-heat rate exceeds a predetermined value (~0.02°C/min), an exotherm is registered. Figure 12-10 shows the temperature versus time curve of a reaction sample in the ARC test,
Safety in Chemical Reaction Engineering
Figure 12-8a. Temperature against time for an adiabatic system.
Figure 12-8b. Pressure against time for an adiabatic system.
927
928
Modeling of Chemical Kinetics and Reactor Design
Figure 12-8c. Rate of temperature rise against temperature for an adiabatic system.
and Figure 12-11 illustrates a sketch of the self-heat rate as a function of temperature. The exotherm starts at ~150°C and ends at a final temperature of ~272°C, resulting in an adiabatic temperature increase of ~122°C. This value is the uncorrected measured temperature increase for both sample and vessel (bomb). The correction involves multiplication by the φ-factor. For example, if the value of the φ-factor from an experiment is 1.68, then the corrected adiabatic temperature is 205°C.
Safety in Chemical Reaction Engineering
929
Figure 12-8d. Pressure and rate of pressure rise against temperautre for an adiabatic system.
The ARC analysis has been extended to determine the conditions that may lead to thermal runaway in reactors or storage vessels [10]. The equipment timeline is defined by the ratio of the heat capacity of the reactor and its contents to the reactor heat transfer area and heat transfer coefficient. This is expressed by θ=
MC p UA
(12-9)
where MCp = heat capacity of the reactor and its contents, J/K U = overall heat transfer coefficient, W/m2K A = heat transfer area, m2 The temperature corresponding to the equipment timeline on the time to maximum rate (TMR) plot is the temperature of no return. Above the temperature of no return, the rate of heat generation from
930
Modeling of Chemical Kinetics and Reactor Design
Figure 12-9. Accelerating rate calorimeter (ARC™). (Source: Arthur D. Little.)
Figure 12-10. ARC temperature versus time plot of a reaction sample.
Safety in Chemical Reaction Engineering
931
Figure 12-11. Self-heat rate analysis. ARC data are shown along with a fitted model obtained by assuming the following kinetic parameters: reaction order = 1, activation energy = 31.08 kcal/mol, and frequency factor = 2.31E12 min–1.
the reaction will exceed the available cooling rate and the reaction will run away. Limitations of using the ARC for pressure-relief design include having to correct for the φ-factor [9,11,12]. The correction can fail in the case of complex reactions. Huff [12] has shown that ARC evaluations can be applied to multiple reactions. He further indicated that the corrected calorimeter data yield conservative approaches of developing detailed computer simulation models.
932
Modeling of Chemical Kinetics and Reactor Design
The advantages of the ARC are [13,14]: • An excellent onset detection sensitivity. • A good theoretical background for the experiment kinetic interpretation. • A means of obtaining pressure information. The disadvantages are: • The experiment duration is much longer than for differential thermal analysis (DTA) tests. • The interpretation of complex kinetics obtained under adiabatic conditions is far from being straightforward. • The correction of the pressure record to adiabatic conditions is a difficult problem. • There is no stirring in the original set-up. • The need for skilled operators and maintenance problems. • Troubleshooting new software on the personal computer against the old control computer. AUTOMATED PRESSURE TRACKING ADIABATIC CALORIMETER (APTAC) The APTAC, developed by Arthur D. Little, is a miniature chemical reactor that measures and analyzes the thermal and properties of exothermic chemical reactions. The results from the APTAC instrument help to identify potential hazards and combat key elements of process safety design including emergency relief systems, process optimization, effluent handling, and thermal stability. The APTAC uses a 130 ml spherical test cell with a 0.51mm-wall thickness situated inside a 4-l pressure vessel as shown in Figure 12-12. The APTAC uses a highpower heater assembly that serves to heat the sample as well as provide temperature control of the chamber surrounding the test cell. Additionally, the APTAC uses a continuous nitrogen supply for pressure balancing. The APTAC is more versatile than the ARC and the principal differences between them are: • Data analysis: Analyzing the basic temperature and pressure data from the APTAC is less complex. The APTAC design gives data that are easier to use than the ARC.
Safety in Chemical Reaction Engineering
933
Figure 12-12. Automated pressure tracking adiabatic calorimeter (APTAC). (Source: Arthur D. Little.)
• Reagent delivery: It is possible to add reagents to the sample while the experiment is running using the APTAC instrument. • Sample venting: The pressure in APTAC’s sample container can be automatically released and the material collected into an external vessel.
934
Modeling of Chemical Kinetics and Reactor Design
The APTAC can function as: • A high-performance, closed-cell adiabatic calorimeter. • A high-temperature and high-pressure reaction calorimeter. • An open test cell from which effluent can be discharged and analyzed for emergency relief system studies. The APTAC is capable of studying exothermic reactions at temperatures from ambient to 500°C and pressures ranging from vacuum to 2,000 psia. It can detect and track exotherms at heat generation rates ranging from 0.04°C/min to 400°C/min. It employs the heat-waitsearch mode of operation coupled with adiabatic tracking of any detected exotherm. This allows standard analysis of the data for information on the activation energy, order of reaction, and heat of reaction. The results obtained during cool-down determine the total amount of gas generated. The large sample size of the APTAC enables additional reagents to be added while the experiment is in progress. This enables the instrument to simulate actual process operations for process development or to determine the effectiveness of quenching agents in controlling runaway reactions. The APTAC collates pressure relief data from the normal closed-cell test, and then releases the sample pressure from the vessel into an external sample collection vessel. The test gives information about maximum rates of temperature rise, gas production, and condensate vapors, which are then used for vent sizing using the DIERS simplified method. The APTAC instrument has reduced maintenance and repair costs because no chemicals vent directly into the calorimeter assembly when the sample pressure is released. The typical φ-factor of the APTAC is 1.15. This is slightly higher than the vent sizing package (VSP) calorimeter because of the thicker wall. VENT SIZING PACKAGE (VSP) The vent sizing package (VSP) was developed by Fauskes & Associates, Inc. The VSP and its latest version VSP2 employ the low thermal mass test cell stainless steel 304 and Hastelloy test cell with a volume of 120 ml contained in a 4-l, high-pressure vessel as shown in Figure 12-13. The typical φ-factor is 1.05–1.08 for a test cell wall thickness of 0.127–0.178 mm. Measurements consist of sample temperature T1 and pressure P1, and external guard temperature T2 and
Safety in Chemical Reaction Engineering
935
Figure 12-13. Vent sizing package (VSP) apparatus. (Source: Fauskes & Associates Inc.)
containment pressure P 2 . During the runaway or the self-heating period, the guard heater assembly serves to provide an adiabatic environment for the test sample by regulating T2 close to T1. For closed (non-vented) test cells, the containment vessel serves to prevent bursting of the test cell by regulating its own pressure P2 to follow the test cell sample pressure P1. This pressure-tracking feature makes it possible to use the thin wall (low φ-factor) test cell design. Vented or open tests, where the vapor or gas generated is vented either into the containment vessel or to an external container, are unique capabilities of the VSP instruments. The typical onset sensitivity is 0.1°C/min for the VSP and 0.05°C/min for the VSP2. VSP experiments allow the comparison of various process versions, the direct determination of the wanted reaction adiabatic temperature rise, and the monitoring of the possible initiations of secondary reactions. If no secondary reaction is initiated at the wanted reaction adiabatic final temperature, a further temperature scan allows the
936
Modeling of Chemical Kinetics and Reactor Design
determination of the temperature difference between the wanted reaction adiabatic final temperature and the subsequent decomposition reaction onset temperature. VSP experiments are not suitable to measure the controlling reactant accumulation under normal process conditions. This is obtained using reaction calorimeters. VSP experiments are suitable to assess the consequences of runaway decomposition reactions after their identification using other screening methods [Differential Thermal Analysis (DTA), Differential Scanning Calorimetry (DSC) and Accelerating Rate Calorimeter (ARC)]. The decomposition is then initiated by a temperature scan or an isothermal exposure, depending on the known kinetic behavior of the reaction. In cases where a reliable baseline cannot be determined on DTA thermograms, a VSP experiment enables a better and safer determination of the decomposition exotherm. VSP experiments provide both thermal information on runaway reactions and information on pressure effects. The type of pressurization, following the DIERS methodology (i.e., vapor pressure, production of non-condensable gases, or both), can be determined from VSP experiments. The following experimental conditions are readily achievable using the VSP [14,15]: • Temperature up to 350–400°C under temperature scan conditions. • Pressure up to 200 bar. • Closed or open test cells. Open test cells are connected to a second containment vessel. Test cells of various materials can be used including stainless steel, Hastelloy C276, and glass. Glass test cells of various sizes and shape are suitable for testing fine chemical and pharmaceutical products/reaction conditions when the process is only in glass vessels or when only small samples are available, or if the samples are very expensive. • Mechanical stirring is recommended for testing polymerization reactions or viscous reaction mixtures. This requires the use of taller containment vessels than the original to install the electric motor for the agitator. REACTIVE SYSTEM SCREENING TOOL (RSST) Fauskes & Associates Inc. developed the RSST as an inexpensive screening tool [15,16]. The RSST (Figures 12-14 and 12-15) consists of a spherical glass reaction vessel and immersion heater (optional),
Safety in Chemical Reaction Engineering
937
Figure 12-14. Reactive system screening tool (RSST) apparatus. (Source: Fauskes & Associates Inc.)
its surrounding jacket heater and insulation, thermocouples and a pressure transducer, and a stainless steel containment vessel that serves as both a pressure simulator and safety vessel. The RSST uses a magnetic stirrer base, a control box containing the heater power supply, temperature/pressure amplifiers, and a data acquisition and control panel. The sample cell volume is 10 ml and the containment volume is 350 ml. The apparatus has a low effective heat capacity relative to that of the sample whose value, expressed as the capacity ratio, is approximately 1.04. This key feature allows the measured data to be directly applied to the process scale.
938
Modeling of Chemical Kinetics and Reactor Design
Figure 12-15. Reactive system screening tool (RSST) test cell. (Source: Fauskes & Associates Inc.)
A sample in the test cell is heated at a constant rate and the sample self-heat rate is obtained as a function of sample temperature. This heat-up rate may be varied and is controlled by feedback from the sample temperature measurement. The imposed linear ramp rate can be varied from 0.1°C/min to ramp rates approaching those required to simulate fire exposure by using the immersion heater option. The heater compensates for losses, and the self-heating rate of an exothermic system is adjusted for heater input. Reagents may be added to a sample during a test. Data handling programs give results of pressure versus temperature, temperature versus time, pressure versus time, and Arrhenius plots.
Safety in Chemical Reaction Engineering
939
The RSST can rapidly and safely determine the potential for runaway reactions. It also measures the temperature rates and, in the case of gassy reactions, pressure increases to allow reliable determinations of the energy and gas release rates. This information is combined with analytical tools to evaluate reactor vent size requirements. This is extremely useful when screening a large number of different chemicals and processes. The advantages of the RSST are: • The small glass test cell (10 ml) is useful when only small samples are available or if the sample is expensive. • The possible installation of the RSST on site when the samples cannot be transported. • The low cost of the RSST. The disadvantages of the RSST compared to the VSP are: • The small test cell makes the study of process reaction steps more difficult. • Only open cell tests are possible using the RSST. • Multiphase or viscous reaction mixtures cannot be stirred well. Figure 12-16 gives a recommended test sequence for identification of reactive system type and vent sizing. PHI-TEC The PHI-TEC II adiabatic calorimeter as shown in Figure 12-17 was developed by Hazard Evaluation Laboratory Ltd. (UK). The PHI-TEC can be used both as a high sensitivity adiabatic calorimeter and as multi-purpose vent sizing device [17,18]. The PHI-TEC employs the principles established by DIERS and includes advanced features compared to the VSP. It also provides important information for storage and handling and provides useful insight into the options suitable for downstream disposal of vented material. The device consists of a low thermal mass test cell of 110 ml volume. This is made of stainless steel with a 0.015-mm wall thickness, but test cells made from other materials can be used. The contents of the cell are mixed using either a magnetically driven stirring bar or a direct drive agitation test cell. The test cell is
Figure 12-16. Recommended test sequence for indentification of reactive system and vest sizing.
940 Modeling of Chemical Kinetics and Reactor Design
Safety in Chemical Reaction Engineering
941
Figure 12-17. PHI-TEC adiabatic calorimeter. (Source: Hazard Evaluation Laboratory Ltd.)
surrounded by three independent guard heaters, which are controlled to match the sample temperature that is measured within the test cell. These reduce heat losses from the sample down to a very low level, and thereby maintain the sample adiabatic condition. The guard heaters can track the sample temperature up to 200°C/min. The test cell and
942
Modeling of Chemical Kinetics and Reactor Design
heaters are mounted in a calorimetry assembly, which sits within a high-pressure containment vessel. A computer handles the temperature control duty and also activates a pressure compensation system. Highpressure nitrogen is admitted to, or bled off from, the pressure vessel so that the pressure in the vessel closely matches the measured sample pressure within the test cell as the pressure in the test cell increases. This capability allows very thin-walled metal cells to be used, which minimizes the thermal capacity of the cell in relation to that of the test sample. This also enables the test cell to be used at pressures up to 138 bara despite its lack of mechanical strength. The computer linked with the instrument is used for data acquisition and control. Singh [19] has provided mathematical models to describe a closed thermal runaway reaction and the effect of venting from data obtained from PHI-TEC experiments. Figure 12-18 shows an overall view of the PHI-TECII adiabatic calorimeter and Figure 12-19 depicts the test
Figure 12-18. An overall view of the PHI-TEC adiabatic calorimeter. (Source: Hazard Evaluation Laboratory Ltd.)
Safety in Chemical Reaction Engineering
943
Figure 12-19. The PHI-TEC II adiabatic calorimeter: Test cell and calorimeter in main pressure vessel rated for use to 138 bara. (Source: Hazard Evaluation Laboratory Ltd.)
cell and calorimeter in the main pressure vessel. Figures 12-20, 12-21, 12-22, and 12-23 show plots of various variables involving adiabatic decomposition of 20 w/w % di-tertiary butyl peroxide (DTBP) in toluene using the PHI-TEC II calorimeter. (text continued on page 866)
944
Modeling of Chemical Kinetics and Reactor Design
Figure 12-20. Temperature versus time plot of 20 w/w% di-tertiary butyl peroxide (φ = 1.09, φ = 1.75, and φ = 2.00). (Source: Hazard Evaluation Laboratory Ltd.)
Figure 12-21. Pressure versus temperature plot of 20 w/w% di-tertiary butyl peroxide (φ = 1.09, φ = 1.75, and φ = 2.00). (Source: Hazard Evaluation Laboratory Ltd.)
Safety in Chemical Reaction Engineering
945
Figure 12-22. dT/dt versus temperature plot of 20 w/w% di-tertiary butyl peroxide (φ = 1.09, φ = 1.75, and φ = 2.00). (Source: Hazard Evaluation Laboratory Ltd.)
Figure 12-23. ln(k* seconds) versus –1,000/Absolute temperature plot of 20 w/w% di-tertiary butyl peroxide (φ = 1.09, φ = 1.75, and φ = 2.00). (Source: Hazard Evaluation Laboratory Ltd.)
946
Modeling of Chemical Kinetics and Reactor Design
(text continued from page 863)
SIMULAR REACTION CALORIMETER Many chemical reactions in the CPI are performed in a semi-batch process under isothermal conditions. The DIERS methodology in sizing the relief system for runaway reactions is based on adiabatic conditions using the batch process. There are instances where a semibatch process under isothermal condition is advantageous in significantly reducing the vent size or even possibly eliminating runaway reaction and the need for pressure relief. Singh [20] performed studies involving the esterification reaction between methanol (CH3OH) and acetic anhydride (CH3CO)2O at a constant temperature of 40°C in a calorimeter known as the SIMULAR. The SIMULAR, developed by Hazard Evaluation Laboratory Ltd., is a chemical reactor control and data acquisition system. It can also perform calorimetry measurements and be employed to investigate chemical reaction and unit operations such as mixing, blending, crystallization, and distillation. Figure 12-24 shows a schematic detail of the SIMULAR, and Figure 12-25 illustrates the SIMULAR reaction calorimeter with computer controlled solids addition. The instrument consists of a reaction vessel with a size range of 0.2–5.0 l and is made of glass, stainless steel, or any other suitable material and surrounded by a heating/cooling jacket. Silicone oil is circulated through the reaction vessel jacket and a heater/chiller unit before being returned to the jacket. The cooling/heating circulation unit is capable of operating from –50 – 300°C, and controlling temperatures to within 0.1°C. A glass condenser can be added for reflux operation at atmospheric pressure (Figure 12-26). Sensor signals such as reactor temperature, oil inlet and outlet temperatures, condenser inlet and outlet temperatures, condenser flow, calibration heater power, and stirrer speed are logged on a computer that monitors and controls the reactor performance. Experiments were performed in the SIMULAR calorimeter using the “power compensation” method of calorimetry (note that it can also be used in the heat flow mode). In this case, the jacket temperature was held at conditions, which always maintain a temperature difference (~20°C) below the reactor solution. A calibration heater was used to (text continued on page 870)
Figure 12-24. Schematic overview of a typical calorimeter. (Source: Hazard Evaluation Laboratory Ltd.)
Safety in Chemical Reaction Engineering 947
948
Modeling of Chemical Kinetics and Reactor Design
Figure 12-25. SIMULAR reaction calorimeter: Computer controlled solids feed. (Source: Hazard Evaluation Laboratory Ltd.)
Safety in Chemical Reaction Engineering
949
Figure 12-26. The SIMULAR reaction calorimeter. Features include pumped liquid feed, gas mass flow control, gas evolution measurement, and distillation equipment. (Source: Hazard Evaluation Laboratory Ltd.)
950
Modeling of Chemical Kinetics and Reactor Design
(text continued from page 866)
provide the power required to maintain the reactor at constant temperature. As the chemical reaction proceeded and heat was generated, the calibration power was varied to maintain constant conditions. Figures 12-27, 12-28, 12-29, and 12-30 give plots of various parameters using the SIMULAR reaction calorimeter.
TWO-PHASE FLOW RELIEF SIZING FOR RUNAWAY REACTION Many methods have been used to size relief systems: area/volume scaling, mathematical modeling using reaction parameters and flow theory, and empirical methods by the Factory Insurance Association (FIA). The Design Institute for Emergency Relief Systems (DIERS) of the AIChE has performed studies of sizing reactors undergoing runaway reactions. Intricate laboratory instruments as described earlier have resulted in better vent sizes. A selection of relief venting as the basis of safe operation is based on the following considerations [21]: • Compatibility of relief venting with the design and operation of the plant/process • Identifying the worst-case scenarios
Figure 12-27. Temperature versus time plot from a semi-batch heat flow experiment. (Source: Hazard Evaluation Laboratory Ltd.)
Safety in Chemical Reaction Engineering
951
Figure 12-28. Acid plus solid gives product 1; product 1 plus mixed acids gives product 2. (Source: Hazard Evaluation Laboratory Ltd.)
Figure 12-29. Acid plus solid gives product 1 (power output and its integral versus time). (Source: Hazard Evaluation Laboratory Ltd.)
952
Modeling of Chemical Kinetics and Reactor Design
Figure 12-30. Product 1 plus mixed acid gives product 2 (power output and its integral versus time). (Source: Hazard Evaluation Laboratory Ltd.)
• Type of reaction • Means of measuring the reaction parameters during the runaway reaction • Relief sizing procedure • Design of the relief system including discharge ducting and safe discharge area RUNAWAY REACTIONS A runaway reaction occurs when an exothermic system becomes uncontrollable. The reaction leads to a rapid increase in the temperature and pressure, which if not relieved can rupture the containing vessel. A runaway reaction occurs because the rate of reaction, and therefore the rate of heat generation, increases exponentially with temperature. In contrast, the rate of cooling increases only linearly with temperature. Once the rate of heat generation exceeds available cooling, the rate of temperature increase becomes progressively faster. Runaway reactions nearly always result in two-phase flow reliefs. In reactor venting, reactions essentially fall into three classifications:
Safety in Chemical Reaction Engineering
953
• Vapor pressure systems • Hybrid (gas + vapor) systems • Gassy systems The significance of these categories in terms of relief is that, once the vent has opened, both vapor pressure and hybrid reactions temper, by losing enough heat through vaporization, to maintain temperature and pressure at an acceptable level. In a gas generating system, there is negligible or sometimes no control of temperature during venting, such that relief sizing is based on the peak gas generation rate. Experimental studies conducted by the testing methods must not only be able to differentiate between the reaction types, but must also simulate large-scale process conditions. The results of the experimental studies should greatly enhance the design of the relief system. The reactor venting categories are reviewed below. Vapor Pressure Systems In this type of reaction, no permanent gas is generated. The pressure generated by the reaction is due to the increasing vapor pressure of the reactants, products, and/or inert solvent as the temperature rises. It is the rate of temperature increase (i.e., power output) between the set pressure and the maximum allowable pressure, which determines the vent size and not the peak rate. Boiling is attained before potential gaseous decomposition (i.e., the heat of reaction is removed by the latent heat of vaporization). The reaction is tempered, and the total pressure in the reactor is equal to the vapor pressure. The principal parameter determining the vent size is the rate of the temperature rise at the relief set pressure. Systems that behave in this manner obey the Antoine relationship between pressure P and temperature T as represented by In P = A + B/T
(12-10)
where A and B are constants and T is the absolute temperature. An example is the methanol and acetic anhydride reaction. Gassy Systems Here, the system pressure is due entirely to the pressure of noncondensible gas rather than the vapor pressure of the liquid. The gas
954
Modeling of Chemical Kinetics and Reactor Design
is the result of decomposition. The exothermic heat release is largely retained in the reaction mass because the cooling potential of volatile materials is not available. As such, both the maximum temperature and maximum gas generation rate can be attained during venting. Gaseous decomposition reactions occur without tempering. The total pressure in the reactor is equal to the gas pressure. The principal parameter determining the vent size is the maximum rate of pressure rise. Unlike vapor-pressure systems, the pressure is controlled (and reduced) without cooling the reaction. A survey within the Fine Chemical Manufacturing Organization of ICI has shown that gassy reaction systems predominate due to established processes such as nitrations, diazotizations, sulphonations, and many other types of reactions [22]. Very few vapor pressure systems have been identified that also generate permanent gas (i.e., hybrid type). Hybrid Systems These are systems that have a significant vapor pressure and at the same time produce non-condensible gases. Gaseous decomposition reaction occurs before boiling—the reaction is still tempered by vapor stripping. The total pressure in the reactor is the summation of the gas partial pressure and the vapor pressure. The principal parameters determining the vent size are the rates of temperature and pressure rise corresponding to the tempering condition. A tempered reactor contains a volatile fluid that vaporizes or flashes during the relieving process. This vaporization removes energy through heat vaporization and tempers the rise in temperature rate due to the exothermic reaction. In some hybrid systems, the generated vapor in a vented reaction is high enough to remove sufficient latent heat to moderate or “temper” the runaway (i.e., to maintain constant temperature). This subsequently gives a smaller vent size. Richter and Turner [23] have provided systematic schemes for sizing batch reactor relief systems. They employed logic diagrams that outlined the various decisions to produce a model of the system. Figure 12-31 reviews the reaction kinetics and thermodynamics required to create a reactor model. Figure 12-32 shows a sequence of steps used to model flow from the reactor, assuming relief is occurring as a homogeneous vapor-liquid mixture. The DIERS program has supported the use of a homogeneous vapor-liquid mixture (froth) model, which
Safety in Chemical Reaction Engineering
955
Figure 12-31. Block flow diagram showing the reaction kinetics and thermodynamics needed to create a reactor model. (Source: Reproduced with permission of the AIChE. Copyright © 1996 AIChE. All rights reserved.)
956
Modeling of Chemical Kinetics and Reactor Design
Figure 12-32. Steps used to model flow from the reactor, assuming relief is occuring as a homogeneous vapor/liquid mixture. (Source: Reproduced with permission of the AIChE. Copyright © 1996 AIChE. All rights reserved.)
Safety in Chemical Reaction Engineering
957
relies on the assumption that the vapor phase is in equilibrium with the batch liquid phase [24]. Figure 12-33 shows the steps used to model compressible vapor venting from the reactor. Table 12-2 lists formulae for computing the area of the three systems. SIMPLIFIED NOMOGRAPH METHOD Boyle [25] and Huff [26] first accounted for two-phase flow with relief system design for runaway chemical reactions. Computer simulation approaches to vent sizing involve extensive thermokinetic and thermophysical characterization of the reaction system. Fisher [27] provided an excellent review of emergency relief system design involving runaway reactions in reactors and vessels. The mass flux through the relief device representing choked two-phase flow through a hole is expressed as: G=
Q m ∆H V = A υ fg
gc C P TS
0.5
(12-11)
For two-phase flow through pipes, an overall dimensionless discharge coefficient, ψ, is applied. Equation 12-11 is referred to as the equilibrium rate model (ERM) for low-quality choked flow. Leung [28] indicated that Equation 12-11 be multiplied by a factor of 0.9 to bring the value in line with the classic homogeneous equilibrium model (HEM). Equation 12-11 then becomes ∆H V g C Q G = m = 0.9ψ A υ fg C P TS where A gc Qm ∆HV υfg CP TS
= = = = = = =
0.5
(12-12)
area of the hole, m2 correction factor 1.0 (kg•m/sec2)/N mass flow through the relief, kg/sec heat of vaporization of the fluid, J/kg change in specific volume of the flashing liquid, m3/kg heat capacity of the fluid (J/kg•K) absolute saturation temperature of the fluid at the set pressure, K
958
Modeling of Chemical Kinetics and Reactor Design
Figure 12-33. Steps used to model compressible vapor venting from the reactor. (Source: Reproduced with permission of the AIChE. Copyright © 1996 AIChE. All rights reserved.)
Safety in Chemical Reaction Engineering
959
Table 12-2 Vent areas and diameters of the vapor, gassy, and hybrid systems Vapor system
Gassy system
Hybrid system
m dT o dt A = 1.5 × 10 −5 • F P s
dP 1 m A = 3 × 10 −6 o 1dt .5 F m t PMAP
dP 1 m A = 5.6 × 10 −6 o dt F m t Ps1.5
4A d= π L/D=0,
0.5
F=1.00
4A d= π
0.5
L/D=0,
F=1.00
4A d= π L/D=0,
0.5
F=1.00
L/D=50, F=0.85
L/D=50, F=0.70
L/D=50, F=0.70
L/D=100, F=0.75
L/D=100, F=0.60
L/D=100, F=0.60
L/D=200, F=0.65
L/D=200, F=0.45
L/D=200, F=0.45
L/D=400, F=0.50
L/D=400, F=0.33
L/D=400, F=0.33
The result is applicable for homogeneous venting of a reactor (low quality, not restricted just to liquid inlet condition). Figure 12-34 gives the value of ψ for L/D ratio. For example, for a pipe length of zero, ψ = 1, and as the pipe length increases, the value of ψ decreases. Equation 12-12 can be further rearranged in terms of a more convenient expression as follows: ∆H V dP = TS υ fg dT
(12-13)
Substituting Equation 12-13 into Equation 12-12 gives dP g C TS G = 0.9 ψ dT C P
0.5
(12-14)
The exact derivative is approximated by a finite difference derivative to yield
960
Modeling of Chemical Kinetics and Reactor Design
Figure 12-34. Correction factor versus L/D for two-phase flashing flow through pipes. (Source: J. C. Leung and M. A. Grolmes, “The Discharge of Two-Phase Flashing Flow in a Horizontal Duct,” AIChE Journal, 33(3), p. 524, 1987.)
dP g C TS G ≅ 0.9 ψ dT C P
0.5
(12-15)
where ∆P = overpressure ∆T = temperature rise corresponding to the overpressure Fauske [29] developed a simplified chart for the two-phase calculation. The relief area was expressed as:
A=
Vρ G ∆t V
where A = relief vent area, m2 V = reactor volume, m3 ρ = density of the reactants, kg/m3
(12-16)
Safety in Chemical Reaction Engineering
961
G = mass flux through the relief (kg/sec•m2) ∆tV = venting time, sec Boyle [25] developed Equation 12-16 by defining the required area as the size that would empty the reactor before the pressure could rise above some allowable pressure for a given vessel. The mass flux G is given by Equations 12-12 or 12-15, and the venting time is given by
∆t V =
( ∆T)(C P )
where ∆T T CP qS
(12-17)
qS = = = =
temperature rise corresponding to the overpressure ∆P temperature heat capacity energy release rate per unit mass at the set pressure of the relief system
Combining Equations 12-16, 12-17, and 12-11 yields A = Vρ(g C C P TS )
–0.5
qS ∆P
(12-18)
Equation 12-18 gives a conservative estimate of the vent area, and the simple design method represents overpressure (∆P) between 10%– 30%. For a 20% absolute overpressure, a liquid heat capacity of 2,510 J/kg • K for most organics, and considering that a saturated water relationship exists, the vent size area per 1,000 kg of reactants is: m2 A= = 1, 000 kg
dT 0.00208 dt °C min PS bar
(12-19)
Figure 12-35 shows a nomograph for determining the vent size. The vent area is calculated from the heating rate, the set pressure, and the mass of reactants. The nomograph is used for obtaining quick vent sizes and checking the results of the more rigorous computation. Crowl and Louvar [30] expressed that the nomograph data of Figure 12-35 applies to a discharge coefficient of ψ = 0.5, representing a discharge L/D of 400.0. However, use of the nomograph at other discharge pipe lengths and different ψ requires a suitable conversion.
962
Modeling of Chemical Kinetics and Reactor Design
Figure 12-35. A vent sizing monogram for tempered (high vapor pressure) runaway chemical reactions. (Source: H. K. Fauske, “Generalized Vent Sizing Monogram for Runaway Chemical Reactions,” Plant/Operations Progress, Vol. 3, No. 4, 1984. Reproduced with permission of the American Institute of Chemical Engineers, Copyright © 1984 AIChE. All rights reserved.)
Safety in Chemical Reaction Engineering
963
VENT SIZING METHODS Vents are usually sized on the assumption that the vent flow is: • All vapor or gas • All liquid • A two-phase mixture of liquid and vapor or gas The first two cases represent the smallest and largest vent sizes required for a given rate at increased pressure. Between these cases, there is a two-phase mixture of vapor and liquid. It is assumed that the mixture is homogeneous, that is, that no slip occurs between the vapor and liquid. Furthermore, the ratio of vapor to liquid determines whether the venting is closer to the all vapor or all liquid case. As most relief situations involve a liquid fraction of over 80%, the idea of homogeneous venting is closer to all liquid than all vapor. Table 12-3 shows the vent area for different flow regimes. VAPOR PRESSURE SYSTEMS These systems are called “tempering” (i.e., to prevent temperature rise after venting) systems because there is sufficient latent heat available to remove the heat of reaction and to temper the reaction at the set pressure. The vent requirements for such systems are estimated from the Leung’s Method [31,32]: A=
MOq 0.5 V dP 0.5 G TS + (C V ∆T ) dT M O
(12-20)
2
Table 12-3 Vent areas for different flow regimes Type of flow All vapor Two-phase: churn turbulent Bubbly Homogeneous All liquid
Required vent area as a multiple of all vapor vent area 1 2–5 7 8 10
964
Modeling of Chemical Kinetics and Reactor Design
Alternatively, the vent area can be expressed as:
A=
MOq 0.5 ∆ H V 0.5 V ∆ G + C T ( ) V M O υ fg
2
(12-21)
where Mo = total mass contained within the reactor vessel prior to relief, kg q = exothermic heat release rate per unit mass, J/(kg•sec), W/kg V = volume of the vessel, m3 CV = liquid heat capacity at constant volume (J/kg•K) ∆HV = heat of vaporization of the fluid, J/kg υfg = change in specific volume of the flashing liquid, (υg – υf), m3/kg The heating rate q is defined by
q=
dT 1 dT C V + 2 dt m dt s
(12-22)
The first derivative of Equation 12-22, denoted by the subscript s, corresponds to the heating rate at the set pressure, and the second derivative, denoted by subscript m, corresponds to the temperature rise at the maximum turnaround pressure. Both derivatives are determined from an experiment (e.g., in the PHI-TEC or VSP). The above equations assume the following: • • • • •
Uniform froth or homogeneous vessel venting occurs. The mass flux, G, varies little during the relief. The reaction energy per unit mass, q, is treated as constant. Constant physical properties CV, ∆HV, and υfg. The system is a tempered reactor system. This applies to the majority of reaction systems.
It is important to use consistent units in applying the above twophase equations. The best procedure is to convert all energy units to
Safety in Chemical Reaction Engineering
965
their mechanical equivalents before solving for the relief area, especially when Imperial (English) units are used. To be consistent, use the SI unit. The vapor pressure systems obey the Antoine relationships: ln P = A +
B T
(12-10)
Differentiating Equation 12-10 yields
B 1 dP =− 2 P dT T
(12-23)
dP B =− 2P dT T
(12-24)
An equation representing the relief behavior for a vent length L/D < 400 is given by [33] 0.5 D p ) ( ∆PS ) TS ( = • 2
MO
dT 2.769 C p dt s
(12-25)
where Mo = allowable mass of the reactor mixture charge (kg) to limit the venting overpressure to PP (psig) DP = rupture disk diameter, in ∆PS = allowable venting overpressure (psi), that is, the maximum venting pressure minus the relief device set pressure PP = maximum venting pressure (psig) PS = relief device set pressure (psig). Note that the relief device set pressure can range from the vessel’s MAWP to significantly below the MAWP. TS = equilibrium temperature corresponding to the vapor pressure where the vapor pressure is the relief device set pressure (K) (dT/dt)s = reactor mixture self-heat rate (°C/min) at temperature TS(K) as determined by a DIERS or equivalent test CP = specific heat of the reactor mixture (cal/g-K or Btu/lb-°F)
966
Modeling of Chemical Kinetics and Reactor Design
Equation 12-25 is a dimensional equation, therefore, the dimensions given in the parameters must be used.
FAUSKE’S METHOD Fauske [32] represented a nomograph for tempered reactions as shown in Figure 12-35. This accounts for turbulent flashing flow and requires information about the rate of temperature rise at the relief set pressure. This approach also accounts for vapor disengagement and frictional effects including laminar and turbulent flow conditions. For turbulent flow, the vent area is dT M O (α D − α O ) 1 dt s A= 2 T 0.5 F S ∆P (1 − α O ) CS
for 0.1PS ≤ ∆P ≤ 0.3PS
(12-26)
where MO = initial mass of reactants, kg (dT/dt)s = self-heat rate corresponding to the relief set pressure, K/sec (dT/dt)m = self-heat rate at turnaround temperature, K/sec PS = relief set pressure, Pa αD = vessel void fraction corresponding to complete vapor disengagement αO = initial void fraction in vessel TS = temperature corresponding to relief actuation, K CS = liquid specific heat capacity (J/kg•K) ∆P = equilibrium overpressure corresponding to the actual temperature rise, Pa ∆T = temperature rise following relief actuation, K F = flow reduction correction factor for turbulent flow (L/D = 0, F ≈ 1.0; L/D = 50, F ≈ 0.85; L/D = 100, F ≈ 0.75; L/D = 200, F ≈ 0.65; L/D = 400, F ≈ 0.55, where L/D is the length-to-diameter ratio of the vent line) Figure 12-36 shows a sketch of the temperature profile for high vapor pressure systems.
Safety in Chemical Reaction Engineering
967
Figure 12-36. Vent sizing model for high vapor pressure systems; due to nonequilibrium effects turnaround in temperature is assumed to coincide with the onset of complete vapor disengagement.
The PHI-TEC or VSP bench scale apparatus can be employed to determine information about the self-heat rate and vapor disengagement when this is not readily available. Additionally, the VSP equipment can be used for flashing flow characteristics using a special bottom vented test cell. Here, the flowrate, GO (kg/sm2), is measured
968
Modeling of Chemical Kinetics and Reactor Design
in a simulated vent line (same L/D ratio) of diameter DO using the vent sizing package (VSP) apparatus. The following recommended scale-up approach in calculating the vent size is:
D ∆P TS If G O T ≥ G T ≅ F ∆T C P,S DO
0.5
where D T is the vent diameter required for turbulent flow, and is expressed by M dT α − α O) 3 O dt ( D DT ≅ 2 F PS (1 − α O )
0.5
C P,S TS
D ∆P TS If G O T ≤ G T ≅ F ∆T C P,S DO
0.25
0.5
the required vent diameter for laminar flow DL is given by G D L = D 2T D O T GO
0.33
GASSY SYSTEMS The major method of vent sizing for gassy system is two-phase venting to keep the pressure constant. This method was employed before DIERS with an appropriate safety factor [34]. The vent area is expressed by: A=
Q g (1 − α ) ρf G1
=
QgM GV
(12-27)
where Qg = volumetric gas generation rate at temperature and in reactor during relief, m3/sec
Safety in Chemical Reaction Engineering
M ρf G, G1 α V
= = = = =
969
mass of liquid in vessel, kg liquid density, kg/m3 mass vent capacity per unit area (kg/sec•m2) void fraction in vessel total vessel volume, m3
Unlike systems with vapor present, gassy systems do not have any latent heat to temper the reaction. The system pressure increases as the rate of gas generation with temperature increases, until it reaches the maximum value. It is possible to underestimate the vent size if sizing depends on the rate of gas generated at the set pressure. Therefore, it is more plausible to size the vent area on the maximum rate of gas generation. Homogeneous two-phase venting is assumed even if the discharge of liquid during venting could reduce the rate of gas generation even further. The vent area is defined by M A = 3.6 × 10 Q g O VPm
0.5
−3
(12-28)
The maximum rate of gas generation during a runaway reaction is proportional to the maximum value of dP/dt and can be calculated from Q g1 =
M O Vt dP M t Pm dt
(12-29)
An equation representing the relief behavior for a length L/D < 400 as in the tempered system is given by [33] 13
2 (D P )2 (M S )( PP ) M O = VP ∆PP (2.07)(TT )(dP dt )
where VP PP MS dP/dt TT
= = = = =
(12-30)
vessel total volume, gal maximum allowable venting pressure, psia sample mass used in a DIERS test or equivalent test, g pressure rise in test, psi/sec maximum temperature in test, K
970
Modeling of Chemical Kinetics and Reactor Design
Pamb = ambient pressure at the end of the vent line, psia ∆PP = PP – Pamb, psi Equation 12-30 is a dimensional equation and the dimensions given in the parameters must be used. HOMOGENEOUS TWO-PHASE VENTING UNTIL DISENGAGEMENT ICI [34] developed a method for sizing a relief system that accounts for vapor/liquid disengagement. They proposed that homogeneous twophase venting occurs and increases to the point of disengagement. Their derivations were based on the following assumptions: • Vapor phase sensible heat terms may be neglected. • Vapor phase mass is negligible. • Heat evolution rate per unit mass of reactants is constant (or average value can be used). • Mass vent rate per unit area is approximately constant (or safe value can be used). • Physical properties can be approximated by average values. The vent area is given by A=
qV(α − α O )
h fg υ f (α − α O ) Gυ f + C∆T υ fg (1 − α O )(1 − α )
where A C G hfg q V ∆T αO α υf υfg
= = = = = = = = = = =
(12-31)
vent area, m2 liquid specific heat (J/kg•K) mass vent capacity per unit area, kg/m2s latent heat, J/kg self-heat rate, W/kg total vessel volume, m3 temperature rise corresponding to the overpressure, K initial void fraction void fraction in vessel liquid specific volume, m3/kg difference between vapor and liquid specific volumes, m3/kg
Safety in Chemical Reaction Engineering
971
Equation 12-31 is valid if disengagement occurs before the pressure would have turned over during homogeneous venting, otherwise it gives an unsafe (too small) vent size. Therefore, it is necessary to verify that
q>
GAh fg υ2f
Vυ fg (1 − α )
(12-32)
2
is satisfied at the point of disengagement. TWO-PHASE FLOW THROUGH AN ORIFICE Sizing formulae for flashing two-phase flow through relief devices were obtained through DIERS. It is based on Fauske’s equilibrium rate model (ERM) and assumes frozen flow (non-flashing) form a stagnant vessel to the relief device throat. This is followed by flashing to equilibrium in the throat. The orifice area is expressed by
W A= CD where A CD CL k P1 T1 x VG VL W λ
= = = = = = = = = = =
xV (V − V )2 C T G L L 1 G + 2 λ kP1
0.5
(12-33)
vent area, m2 actual discharge coefficient average liquid specific heat ( J/kg•K) isentropic coefficient pressure in the upstream vessel, N/m2 temperature corresponding to relief actuation, K mass fraction of vapor at inlet specific volume of gas, m3/kg specific volume of liquid, m3/kg required relief rate, kg/s latent heat, J/kg
The theoretical rate is given by W = Af(2∆P • ρ)0.5
(12-34)
For a simple sharp-edged orifice, the value of CD is well established (about 0.6). For safety relief valves, its value depends on the shape
972
Modeling of Chemical Kinetics and Reactor Design
of the nozzle and other design features. Additionally, the value of CD varies with the conditions at the orifice. For saturated liquid at the inlet, Equation 12-33 simplifies to yield
W (VG − VL ) (C L T1 ) A= CDλ
0.5
=
W dP T CD 1 dT C L
0.5
(12-35)
These equations are based on the following assumptions: • • • •
Vapor phase behaves as an ideal gas Liquid phase is an incompressible fluid Turbulent Newtonian flow Critical flow—this is usually the case since critical pressure ratios of flashing liquid approach the value of 1
It is recommended that a safety factor of at least 2.0 be used [34]. In certain cases, lower safety factors may be employed. The designer should consult the appropriate process safety section in the engineering department for advice. Table 12-4 lists the applicability of both Leung and Fauske’s methods. Conditions of Use • If Fauske’s method yields a significantly different vent size, then the calculation should be reviewed. • The answer obtained from the Leung’s method should not be significantly smaller than that of Fauske’s method. • ICI recommends a safety factor of 1–2 on flow or area. The safety factor associated with the inaccuracies of the flow calculation will depend on the method used, the phase nature of the flow, and the pipe friction. For two-phase flow, use a safety factor of 2 to account for friction or static head. • Choose the smaller of the vent size from the two methods. A systematic evaluation of venting requires information on: • The reaction—vapor, gassy, or hybrid • Flow regime—foamy or nonfoamy
Safety in Chemical Reaction Engineering
973
• Vent flow—laminar or turbulent • Vent sizing parameters—dT/dt, ∆P/∆T, and ∆T It is important to ensure that all factors (e.g., long vent lines) are accounted for, independent of the methods used. Designers should ascertain that a valid method is chosen rather than the most convenient or the best method. For ease of use, the Leung’s method for vapor pressure systems is rapid and easy. Different methods should give vent sizes within a factor of 2. Nomographs give adequate vent sizes for long lines up to a L/D of 400, but sizes are divisible by 2 for nozzles. The computer software VENT was developed to size two-phase relief for vapor, gassy, and hybrid systems.
DISCHARGE SYSTEM DESIGN OF THE VENT PIPE It is necessary to know the nature of the discharging fluid in determining the relief areas. DIERS and ICI techniques can analyze systems that exhibit “natural” surface active foaming and those that do not. DIERS further found that small quantities of impurities can affect the flow regime in the reactor. Additionally, a variation in impurity level may arise by changing the supplier of a particular raw material. Therefore, care should be taken when sizing emergency relief on homogeneous vessel behavior, that is, two-phase flow. In certain instances, pressure relief during a runaway reaction can result in threephase discharge, if solids are suspended in the reaction liquors. Solids can also be entrained by turbulence caused by boiling/gassing in the bulk of the liquid. Caution is required in sizing this type of relief system, especially where there is a significantly static head of fluid in the discharge pipe. Another aspect in the design of the relief system includes possible blockage of the vent line. This could occur from the process material being solidified in cooler sections of the reactor. It is important to consider all discharge regimes when designing the discharge pipework. Safe Discharge Reactors or storage vessels are fitted with an overpressure protection vent directly to roof level. Such devices (e.g. relief valves) protect only (text continued on page 896)
The overpressures are limited in the range of 10%–30% of absolute set pressure, (i.e., 0.1Ps ≤ ∆P ≤ 0.3Ps). It assumes that flow is turbulent and that the vapor behaves as an ideal gas. The method incorporates the equilibrium rate model (ERM) for vent flow capacity when friction is negligible. Additionally, a correction factor is used for longer vent lines of constant diameter and with negligible static head change. It allows for total vapor-liquid disengagement of fluids that are not “natural” surface active foamers.
To account for disengagement, the vessel void fraction at disengagement should be evaluated (i.e., the point at which the vent flow ceases to be two-phase and starts to be vapor only).
2. The method includes the mass unit vent flow capacity per unit area, G. This allows using any applicable vent capacity calculation method.
3. The heat evolution rate per unit mass, the vent capacity per unit area, physical properties (e.g., latent heat of liquid, specific heat, and vapor/liquid specific volumes) are constant.
4. A hand calculation method that can be used to take into account two-phase relief when the materials in the vessel are “natural” surface active foamers.
Fauske’s method
1. The overpressures are limited in the range of 0%–50% of absolute set pressure, (i.e., 0 ≤ ∆P ≤ 0.5Ps).
Leung’s method
Table 12-4 Applicability of recommended vent sizing methods
974 Modeling of Chemical Kinetics and Reactor Design
A G hfg υf υfg V αD q = = = = = = = =
vent area, m2 mass vent capacity per unit area (kg/m2s) latent heat, J/kg liquid specific volume (m3/kg) differences between vapor and liquid specific volumes (m3/kg) total vessel volume, m3 void fraction in vessel at disengagement heat release rate per unit mass of reactor contents (W/kg)
However, when disengagement is not accounted for, then αD = 1 and the above equation is not required.
Vυ fg (1 − α D ) 2
G Ah fg υ 2f
The criterion for safe use of the method takes into account that disengagement is
6. Methods are given for the bubbly and churn-turbulent flow regimes within the vessel.
q<
The method is potentially unsafe if early disengagement (i.e., before the pressure would otherwise have turned over during two-phase venting) occurs.
5. The method uses the drift-flux level swell calculation models to take into account there being more vapor in the inlet stream to relief device than average for the vessel.
Safety in Chemical Reaction Engineering 975
976
Modeling of Chemical Kinetics and Reactor Design
(text continued from page 893)
against common process maloperations and not runaway reactions. The quantity of material ejected and the rate of discharge are low, resulting in good dispersion. The increased use of rupture (bursting) discs can result in large quantities (95% of the reactor contents) being discharged for foaming systems. The discharge of copious quantities of chemicals directly to the atmosphere can give rise to secondary hazards, especially if the materials are toxic and can form a flammable atmosphere (e.g., vapor or mist) in air. In such cases, the provision of a knockout device (scrubber, dump tank) of adequate size to contain the aerated/foaming fluid is required. The regulatory authorities can impose restrictions on discharging effluent from the standpoint of pollution. Therefore, reliefs are seldom vented to the atmosphere. In most cases, a relief is initially discharged to a knockout system to separate the liquid from the vapor. The liquid is collected and the vapor is then discharged to another treatment unit. The vapor treatment unit depends on the hazards of the vapor and may include a vent condenser, scrubber, incinerator, flare, or a combination of these units. This type of system is referred to as the “total containment system” as shown in Figure 12-37. The knockout drum is sometimes called a catchtank or blowdown drum. The horizontal knockout serves as both a vapor-liquid separator as well as a holdup vessel for the disengaged liquid. These are commonly used where there is greater space such as in petroleum refineries and petrochemical plants. The two-phase mixture enters at one end and the vapor leaves at the opposite end. Inlets may be provided at each end with a vapor outlet at the center of the drum to minimize vapor velocities involving twophase streams with very high vapor flowrates. When there is limited space in the plant, a tangential knockout drum is employed as illustrated in Figure 12-38. Coker [35] has given detailed design procedures of separating gas-liquid separators. Direct Discharge to the Atmosphere Careful consideration and analysis by management are essential before flammable or hazardous vapors are discharged to the atmosphere. Consideration and analysis must ensure that the discharge can be performed without creating a potential hazard or causing environmental problems. The possible factors are:
Safety in Chemical Reaction Engineering
977
Figure 12-37. Relief containment system with blowdown drum. The blowdown drum separates the vapor from the liquid. (Source: Grossel [39].)
Figure 12-38. Tangential inlet knockout drum with separate liquid catchtank. (Source: Grossel [39].)
978
Modeling of Chemical Kinetics and Reactor Design
• Exposure of plant personnel and/or the surrounding population to toxic vapors or corrosive chemicals • Formation of flammable mixtures at ground level or elevated structures • Ignition of vapors at the point of emission (blowdown drum vent nozzle) • Air pollution These factors and methods for evaluating their effects are discussed in greater detail in American Petroleum Institute publications (API RP521) [36], Lees [37], and Wells [38]. Special care should be taken when designing the vapor vent stack to ensure that the tip faces straight up (i.e., no goose-neck) to achieve good dispersion. The stack should not be located near a building so as to avoid vapor drifting into the building. However, if the drum is near a building, the stack should extend at least 12 ft above the building floor. Grossel [39] has provided various descriptions of alternative methods of disposal.
RUPTURE (BURSTING) DISC Some method of pressure relief is required on all pressure vessels and for other process equipment where increasing pressure might rupture the vessel. Much of the piping used in modern chemical operations also requires overpressure protection. Safety relief valves or rupture discs are employed for pressure relief. In many cases, either a rupture disc or a safety relief valve can be used. Safety relief valves are usually used for process protection and rupture discs are used for vessel protection. The safety relief valve or rupture disc must be designed to operate at a known pressure and prevent the pressure within the system from increasing. Therefore, it is important to consider the flowrate the valve can handle. A rupture disc is a simple device that essentially consists of a thin material held in place between two flanges. The disc is usually made of metal, although it may be made of other materials. The choice of material is important because the rupture disc must be designed to close tolerances to operate properly. During emergency venting, the disc ruptures when the pressure level rises to a chosen level. The vessel is then vented and the pressure in the vessel eventually drops
Safety in Chemical Reaction Engineering
979
to atmospheric pressure. The rupture disc should be large enough to vent the vessel at the required maximum rate. Safety relief devices (i.e., safety relief valves) may also be designed to open at a given temperature. Sometimes, a combination of relief devices are used that fail at either a given temperature or a given pressure. An important application of a rupture disc device is at the inlet of a pressure relief valve. The sizing of the pressure relief valve or rupture disc device combination requires that the pressure relief valve first be sized to meet the required relieving capacity. The normal size of the rupture disc device installed at the inlet of the pressure relief valve must be equal to or greater than the nominal size of the inlet connection of the valve to permit sufficient flow capacity and valve performance. The failure modes of rupture discs are [40]: (a) (b) (c) (d) (e)
Failure to rupture at maximum bursting pressure. Failure to open fully at maximum bursting pressure. Premature rupture below minimum bursting pressure. Leakage through the disc to the vent (through cracks or pinholes). Leakage through the holder to the atmosphere.
Cases (a) and (b) are the critical failure modes for protecting the equipment, and the reliability of the disc in these modes is referred to as the primary reliability. Case (c) is inconvenient and sometimes costly, but it is not usually dangerous unless the containment or disposal system for the discharge is inadequate. Cases (d) and (e) are comparatively rare. The design of a rupture disc depends on the vented material. If a gas or liquid alone is to be vented, the design is relatively straightforward. The relief system can be designed on the basis of single-phase fluid flow [41]. However, in many systems containing liquids under their own vapor pressure, emergency venting can be a combination of liquid and vapor. In such cases, the two-phase fluid must be taken into account. The methods (DIERS) used to design such relief systems are substantially different than those for single-phase fluids. Rupture discs should be removed from service at predetermined intervals for visual inspection. Depending on the condition of the disc and recommendations by the manufacturers, they are either replaced or returned to service. The most common mode of failure is case (c), premature rupture below the minimum bursting pressure. An analysis of this mode of failure indicates that this can be the result of:
980
Modeling of Chemical Kinetics and Reactor Design
• Incorrect specification of the disc. This includes overlooking intermittent vacuum conditions and other pressure/temperature transients, failure to predict corrosion, or operating at a pressure too close to the rupture disc pressure, resulting in fatigue failure. • Damage to the disc by faulty handling before installation or during maintainance. • Incorrect installation of the disc, especially by faulty fitting. • Damage of flawed disc is undetected during installation. • Disc left in service beyond its recommended service life. • Incorrect disc fitting. ASME Code Rupture Disc Terminology The following provide rupture disc terminology definitions: • A rupture disc device is a non-reclosing pressure relief device actuated by inlet static pressure and designed to function by the bursting of a pressure containing disc. • A rupture disc is the pressure containing and pressure sensitive element of a rupture disc device. • A rupture disc holder is the structure that encloses and clamps the rupture disc in position. • The manufacturing design range is a range of pressure within which the marked burst pressure must fail to be acceptable for a particular requirement as agreed upon between the rupture disc manufacturer and the user or his agent. • The specified disc temperature supplied to the rupture disc manufacturer is the temperature of the disc when the disc is expected to burst. • A batch of rupture discs are those discs manufactured of a material at the same time and the same size, thickness, type, heat, and manufacturing process including heat treatment. • The minimum net flow area is the calculated net area after a complete burst of the disc with appropriate allowance for any structural or support members that may reduce the net flow area through the rupture disc device. The net flow area for sizing purposes should not exceed the nominal pipe size area of the rupture disc device. • The certified flow resistance factor, KR, is a dimensionless factor used to calculate the velocity head loss that results from the
Safety in Chemical Reaction Engineering
981
presence of a rupture disc device in a pressure relief system. The relationships between the relief terms in the glossary are illustrated in Figure 12-39. The design of safety relief valves for single-phase fluids such as vapor, liquid, steam, air, and fire conditions is described elsewhere [41].
Figure 12-39. Guidelines for relief pressures. (Source: API RP 521 Guide for Pressure-Relieving and Depressurizing systems, 2nd ed. Washington, DC, American Petroleum Institute, 1982, p. 23.)
982
Modeling of Chemical Kinetics and Reactor Design
Rupture Disc Sizing Methodologies The coefficient of discharge method (Kd = 0.62) was specified to calculate the capacity of the rupture disc device. However, the validity of this method is limited to a disc mounted close to the pressure vessel and the discharging to atmosphere. The ASME Code provides guidance for the limited use of this method: • The disc must discharge to the atmosphere. • The disc must be installed within 8 pipe diameters of the vessel nozzle. • The length of discharge piping must not be greater than 5 pipe diameters. The resistance to flow method (KR), which has been employed by industry for years, has now been adopted by the ASME Code for rupture disc. Sizing is performed on a relief system basis and not by capacity of individual components. The key elements of this method are: • The rupture disc is treated as another component in the relief system that provides some resistance to flow. • System relief capacity must be multiplied by a factor of 0.90. • ASME Code default resistance to flow factor KR = 2.4. • Certified resistance factors KR can be provided by the rupture disc manufacturer for each disc model. • Based on Darcy formula (Crane 410), hL = f(L/D • v2/2g) ∴ KR = f(L/D). • API recommendation for rupture disc has been L/D = 75 ∴ KR = 0.02(5) = 1.5. • Certified values based on tests of specific disc models in accordance with ASME Section VIII and PTC25. Manufacture Certification Significant changes by the ASME Code have been employed that now have direct impact on the use of rupture disc devices. The change to the Code affecting rupture disc manufacturers is the application of the UD Code symbol to rupture discs that meet the requirements of the ASME Code. Authorization to use the UD stamp is based on an audit by an ASME representative of various manufacturing, testing,
Safety in Chemical Reaction Engineering
983
and quality assurance systems. Additionally, validation tests are performed to ensure close agreement between production discs and certified discs. Rupture Disc Performance Requirements The ASME Code provides requirements for rupture disc performance. The rupture tolerance at the specified disc temperature should not exceed ±2 psi for marked pressure up to and including 40 psi and ±5% for marked burst pressures above 40 psi. The rupture disc must be marked at a pressure within the manufacturing range. The manufacturing ranges available are defined in the product literature for each rupture disc model. Rupture discs are typically manufactured to order, where each order represents a lot. The ASME Code defines three methods of acceptance testing for rupture discs. The most common method requires that at least two discs from the lot be burst tested at the specified disc temperature. The results of these tests must fall within the rupture tolerance. Table 12-5 shows the changes between the old requirements and the new sizing methodology and certification process.
Table 12-5 Rupture disc requirements Old requirements
New requirements
Manufacturer’s name
Manufacturer’s name
Model or part number
Model or part number
Lot number
Lot number
Disc material
Disc material
Nominal size
Nominal size
Stamped burst pressure
Marked burst pressure
Specified disc temperature
Specified disc temperature
Capacity
Minimum net flow area Certified flow resistance, KR ASME UD code symbol
984
Modeling of Chemical Kinetics and Reactor Design
INHERENTLY SAFE PLANTS IN REACTOR SYSTEMS Hazards should be considered and if possible eliminated at the design stage or in the process development where necessary. This involves considering alternative processes, reducing or eliminating hazardous chemicals, site selection or spacing of process units. It is essential to consider inherently safer principles in the design stage because designers may have various constraints imposed on them by the time the process is developed. Englund [42] has given details of inherently safer plants of various equipment in the CPI. He emphasized the importance of user friendly plants as originally expatiated by Kletz [43]. The following reviews the practical application to reactor systems. REACTOR SYSTEM The following should be considered in designing an inherently safer plant involving reactor systems: 1. A good understanding of reaction kinetics is required to establish safe conditions for operation of exothermic reactions. 2. Use continuous reactors if possible. It is usually easier to control continuous reactors than batch reactors. If a batch reaction system is required, minimize the amount of unreacted hazardous materials in the reactor. Figures 12-40 and 12-41 show typical examples. Methods have been developed for improving batch process productivity in the manufacture of styrene-butadiene latex by the continuous addition of reactants so the reaction occurs as the reactor is being filled. These are not continuous processes even though the reactants are added continuously during most of a batch cycle. The net result is that reactants can be added almost as fast as heat can be removed. There is relatively little hazardous material in the reactor at any time because the reactants, which are flammable or combustible, are converted to non-hazardous and non-volatile polymer very quickly. 3. If possible, produce and consume hazardous raw materials in situ. Some process raw materials are so hazardous to ship and store that it is very desirable to minimize the amount of these materials on hand. In some cases, it is possible to achieve this
Safety in Chemical Reaction Engineering
985
Figure 12-40. Process A: Batch reaction with all reactants added at the beginning of the reaction. There is a considerable amount of flammable and hazardous material in the reactor at the beginning. (Source: S. M. Englund, “Inherently Safer Plants: Practical Applications,” Process Safety Progress, Vol. 14, No. 1, pp. 63–70, AIChE, 1995.)
986
Modeling of Chemical Kinetics and Reactor Design
Figure 12-41. Process B: Batch reaction with reactants added during the reaction. Little flammable and hazardous material are present at any time. A reflux (or knockback) condenser is used to provide additional heat transfer. (Source: S. M. Englund, “Inherently Safer Plants: Practical Applications,” Process Safety Progress, Vol. 14, No. 1, pp. 63–70, AIChE, 1995.)
Safety in Chemical Reaction Engineering
4.
5. 6.
7.
8.
9.
10.
987
by using less hazardous chemicals, so there is only a small amount of the hazardous material in the reactor at any time. Liquid-phase of solid-phase reactors contains more material than vapor-phase reactors and thus contains more stored energy than vapor-phase reactors. Using high purity raw materials and products can reduce the amount the waste material that must be handled. Consider designing the reactor for the highest possible pressure in case of a runaway reaction to reduce the possibility of releasing material to the environment. For example, for a certain process in the manufacture of polystyrene, the composition in the reactor included monomer, polymer, and solvent. The maximum pressure that could be reached by adiabatic polymerization of the mixture in the reactor, beginning at the reaction temperature of 120°C (248°F), was about 300 psig or 2,068 kPa (gauge). With this knowledge, it was possible to design polymerization equipment that will withstand this pressure, plus a reasonable safety factor, with considerable confidence that a runaway will not cause a release of material through a pressure relief system or because of an equipment rupture. Limit the total possible charge to a batch reactor by using a precharge or feed tank of limited capacity. Alternatively, limit the addition rate by selecting a pump with a maximum capacity lower than the safe maximum addition rate for the process, or by using restriction orifices. The maximum or minimum temperature attainable in a vessel can be limited by properly designed jacket heating systems. If steam heating is used, maximum temperatures can be limited by controlling steam pressure. A steam desuperheater may be needed to avoid excessive temperature of superheated steam from a pressure letdown station. Tubular reactors often offer the greatest potential for inventory reduction. They are usually simple, have no moving parts, and a minimum number of joints and connections that can leak. Mass transfer is often the rate-limiting step in gas-liquid reactions. Novel reactor designs that increase mass transfer can reduce reactor size and may also improve process yields.
988
Modeling of Chemical Kinetics and Reactor Design
SCALE-UP In scale-up, runaway exothermic chemical reactions can be prevented by taking appropriate safety measures. The onset or critical temperature for a runaway reaction depends on the rate of heat generation and the rate of cooling, which are closely linked to the dimensions of the vessel. This can be represented by the rate of heat generation being proportional to the volume of the reaction mixture. In other words, Rate of heat generation ∝ volume The rate of natural cooling is proportional to the surface area of the vessel and is represented by Rate of cooling ∝ surface area This shows that as the vessel size increases, the volume increases at a faster rate than the surface area. Thus, care must be taken before scale-up is implemented as even a small increase in volume can result in insufficient cooling and subsequent loss of control. The chemical reaction rate is generally a function of a reactant concentration and temperature. In the case of an exothermic reaction, unless the heat of reaction is removed, an increase in temperature may result in a runaway reaction. For most homogeneous reaction, the rate is increased by a factor of 2 or 3 for every 10°C rise in temperature. This is represented by QG αe–E/RT or
(12-36)
QG = Ae–E/RT
(12-37)
where A E QG R T
= = = = =
pre-exponential (Arrhenius) factor activation energy rate of heat generation universal gas constant temperature, K
The rate of heat generation depends on four main factors: 1. Reaction temperature 2. Whether the reactor operates in batch or semi-batch mode
Safety in Chemical Reaction Engineering
989
3. Whether reactant accumulation occurs 4. The occurrence of thermal events (e.g., precipitation, decomposition, gas evolution, phase change) If an external jacket or internal coil is used through which coolant flows at temperature TC to remove the heat, then the rate of heat removal is represented by Rate of heat removal ∝ (Tr – TC) Qc = UA(Tr – Tc) where A Qc Tc Tr U
= = = = =
(12-38)
surface area of heat transfer rate of heat removal coolant temperture reactant temperture overall heat transfer coefficient
The rate of heat removal also depends on four main factors: 1. The effective surface area for heat transfer 2. The temperature difference between the reactant mass and coolant 3. The thermal properties of the reaction mixture, vessel walls, and coolant 4. The nature of the coolant Hence, the rate of heat generation is exponential with reaction temperature T r, but the heat removal rate is approximately linear because U is a weak function of T (Chapter 6). Therefore, a critical value of Tr will exist at which control is lost. The rate of heat generation from an exothermic reaction is directly related to the mass of reactants involved. This and the ability to remove the heat, is an essential consideration in the scale-up of reactors. In a conventional vertical cylindrical reaction vessel of diameter D, The volume (and hence mass) of reactants α D2L where L is the height. In a convective heat transfer to a coolant in an external jacket, heat transfer area α D • L
990
Modeling of Chemical Kinetics and Reactor Design
The ratio is heat transfer area D•L α potential heat release D 2 • L α
1 D
(12-39)
As the size of the vessel increases, the ratio becomes increasingly unfavorable. Thus, there is a critical value for D for which an exothermic reaction can easily be controlled on a laboratory scale and may be hazardous on a larger scale. Heat Transfer Film Coefficient Empirical dimensionless group correlations have been used in the scale-up process. In particular, the correlation for the inside film heat transfer coefficient for agitated, jacketed vessels has been employed for the scale-up to a larger vessel. Reaction calorimeters are often used to give some indication of heat transfer coefficients compared to water in the same unit. Correlation for plant heat transfer is of the general form Nusselt = f Prandtl Number a Reynolds Number b Viscosity ( )( ) factor Number
c
This is expressed mathematically as C pµ hiD = f k k where hi f k ρ N d D µ Cp
= = = = = = = = =
0.33
ρNd 2 µ
0.67
µb µw
0.14
(12-40)
inside film coefficient heat transfer coefficient (W/m2•K) geometric factor thermal conductivity of wall material (W/m•K) density, kg/m3 speed of agitator (1•sec–1) diameter of agitator, m reactor diameter, m viscosity, Nsm–2 specific heat at constant pressure (J/kg•°C)
Safety in Chemical Reaction Engineering
991
The overall heat transfer coefficient U is defined by
1 1 x 1 = + + U hi k ho
(12-41)
where ho = jacket side heat transfer coefficient k = thermal conductivity x = wall thickness The inside convective heat transfer coefficient hi is the only element of the overall heat transfer coefficient U that varies with the agitation speed N. If heat is removed from an agitated reactor using an internal coil or external jacket, the overall heat transfer rate depends on the rotation speed of the agitator N and if the process side offers the major resistance. This is expressed by U α (N)2/3
(12-42)
Therefore, a failure of agitation may result in hot spots and a runaway reaction.
HAZARD AND OPERABILITY STUDIES (HAZOP) The design and operation of a process plant form an integral part of safety and systematic procedures and should be employed to identify hazards and operability and, where necessary, should be quantified. During the design of a new plant, the hazard identification procedure is repeated at intervals. This is first performed on the pilot plant before the full-scale version as the design progresses. Potential hazards whose significance can be assessed with the help of experiments are often revealed by this study. The hazard and operability study (HAZOP) identifies a potential hazard. It provides little information on risk and consequences or its seriousness. However, by assessing the potential hazard, sometimes the designer may decide that the consequences of the hazard are either trivial or unlikely to be ignored. In certain instances, the solution is obvious and the design is modified. A fault tree analysis is useful where the consequences of the hazard are severe, or where its causes are many. The fault tree indicates how various events or combinations of events can give rise to a hazard. It is employed to identify the most
992
Modeling of Chemical Kinetics and Reactor Design
likely causes of the hazard and, thus, show where additional safety precautions will be most effective. Keltz [44] and Barton and Rogers [5] have provided excellent texts with case studies on HAZOP. A HAZOP study is a structured review of the plant design and operating procedures. The main goals are to: • Identify potential maloperations • Assess their consequences • Recommend corrective actions The recommended actions may eliminate a potential cause or interrupt the consequences. They involve: • • • • •
Pipework or other hardware changes Changes in operating conditions More precise operating instructions Addition of alarms with prescribed operator responses Addition of automatic trip systems
The procedure for a HAZOP study is to apply a number of guide words to various sections of the process design intention. The design intention informs what the process is expected to carry out. Table 12-6 shows these guide words, and Figure 12-42 summarizes the entire procedure. Common property words are: • • • • •
Concentration Flowrate or amount Level Heat transfer Pressure
• • • •
React Separate Temperature Particle size
STUDY CO-ORDINATION HAZOP is a structured review exercise performed by a team of between three and six people, one of whom acts as a chairman. Another member of the team acts as a secretary and records the results of the proceeding. A typical team comprises: • Chairman: study leader, experienced in hazop. • Project or design engineer: usually a mechanical engineer, responsible for keeping the costs within budget.
Complete negation of the design intention.
Quantitative increase or decrease. Design intention achieved together with something else. Design intentions only partly achieved. Logical opposite of the intention. Complete substitution.
More or less
As well as
Part of
Reverse
Other than
Meaning
No
Guide word
Applicable where the wrong material flows in a line or the wrong reagent is charged to a reactor or the required reaction does not occur but others do.
Applicable principally to flow.
It is more precise to use the guide word “less” wherever possible. However, fluctuations in a property word are covered by part of.
Flow as well as describes contamination in a pipeline. React as well as covers side reactions.
Applicable to all property words.
Application to flow, concentration, react, heat transfer, separate and similar functions. No level means an empty vessel or a twophase interface is lost.
Explanation
Table 12-6 List of guide words used for the HAZOP procedure
Safety in Chemical Reaction Engineering 993
994
Modeling of Chemical Kinetics and Reactor Design
Figure 12-42. HAZOP procedure.
• Process engineer: usually the chemical engineer who developed the flowsheet. • Commissioning manager: usually a chemical engineer, who will have to start up and operate the plant. • Control system design engineer: modern plants contain sophisticated control and trip systems and HAZOPs often result in the addition of yet more instrumentation.
Safety in Chemical Reaction Engineering
995
• Research chemist: if new chemistry is involved. • Independent team leader: an expert in the HAZOP technique whose job is to ensure that the team follows the procedure. The team should have a wide range of knowledge and experience. If a contractor designs the plant, then the HAZOP team should include people from both the contractor and client organizations. On a computercontrolled batch plant, the software engineer should be a member of the HAZOP team, which should include at least one other person who understands the computer logic. In an existing plant, the team should include several people with experience of the plant. A typical team comprises: • Plant manager: responsible for plant operation. • Process foreman: knows what actually happens rather than what is supposed to happen. • Plant engineer: responsible for mechanical maintenance such as testing of alarms and trips, as well as installation of new instruments. • Process investigation manager: responsible for investigating technical problems and for transferring laboratory results to plantscale operations. • Independent team leader. HAZOP OF A BATCH PROCESS A HAZOP study of a batch processing plant involves a review of the process as a series of discrete stages, as the conditions in a single reactor change with time in a given cycle. Variations in the rate of change, as well as changes in the duration of settling, mixing, and reacting are important deviations. A HAZOP on a batch process includes the flowrates of service fluids—it is more common to look at the reactants in terms of amounts charged or discharged rather than flowrates. Sequential operating instructions are applied to identify the design intent through various stages of the process. HAZOP guide words can then be applied to each design intent instead of the process line. For example, for the instruction “raise concentration or temperature to a specified value for a given time,” the HAZOP would consider the consequences of not achieving or exceeding the desired concentration or temperature in the specified time. To illustrate further, if an instruction states that “1 tonne of A has to be charged to a reactor,” then the team should consider deviations such as
996
Modeling of Chemical Kinetics and Reactor Design
DON’T CHARGE CHARGE MORE CHARGE LESS CHARGE AS WELL AS CHARGE PART OF CHARGE OTHER THAN REVERSE CHARGE
A A A A A (if A is a mixture) A A (that is, can flow occur from the reactor to the A container?)
This can be the most serious deviation if A A A A
IS IS IS IS
ADDED ADDED ADDED ADDED
EARLY LATE TOO QUICKLY TOO SLOWLY
Many accidents occur because process materials flow in the wrong direction. For example, ethylene oxide and ammonia were reacted to make ethanolamine. Some ammonia flowed from the reactor in the opposite direction, along the ethylene oxide transfer line into the ethylene oxide tank, past several non-return valves and a positive displacement pump. It got past the pump through the relief valve, which discharged into the pump suction line. The ammonia reacted with 30m3 of ethylene oxide in the tank, which ruptured violently. The released ethylene oxide vapor exploded causing damage and destruction over a wide area [5]. A hazard and operability study might have disclosed the fact that reverse flow could occur.
HAZAN Hazard analysis (HAZAN) is a quantitative way of assessing the likelihood of failure. Other names associated with this technique are risk analysis, quantitative risk assessment (QRA), and probability risk assessment (PRA). Keltz [44] expressed the view that HAZAN is a selective technique while HAZOP can be readily applied to new design and major modification. Some limitations of HAZOP are its inability to detect every weakness in design such as in plant layout, or miss hazards due to leaks on lines that pass through or close to a unit but carry material that is not used on that unit. In any case, hazards should
Safety in Chemical Reaction Engineering
997
generally be avoided by changing the design. Assessing hazard by HAZAN or any other technique should always be the alternative choice. A small team, similar to that used in HAZOP, carries out hazard analysis. The three steps in HAZAN are: 1. Estimate how frequently the incident will occur. 2. Estimate the consequences to employees, members of the public, plant, and profits. 3. Compare the results of the first two steps with a target or criterion and decide whether it is necessary to act to reduce the incident’s frequency or severity. FAULT TREE ANALYSIS Fault tree analysis is used to assess the frequency of an incident. A fault tree is a diagram that shows how primary causes produce events, which can contribute to a particular hazard. There are several pathways in which a single primary cause can combine with other primary causes or events. Therefore, a single cause may be found in more than one hazard and may occur at different locations in the fault tree. The graphical structure of the fault tree enables the primary causes and secondary events that produce the hazards to be combined. It is then possible to compare the relative contributions of the different events to the probability of the hazardous outcome by employing the probability of occurrence of causes and events on the fault tree. Example 12-1
An 800-gal reactor containing a styrene mixture with a specific heat of 0.6 cal/gm °C has a 10-in. rupture disk and a vent line with equivalent length = 400. The vessel MAWP is 100 psig and the rupture disk set pressure is 20 psig. The styrene mixture had a self-heat rate of 60°C/min at 170°C as it is tempered in a DIERS venting test. Determine the allowable reactor mixture charge to limit the overpressure to 10% over the set pressure. Solution Using Equation 12-25 gives
998
Modeling of Chemical Kinetics and Reactor Design 0.5 D p ) ( ∆PS ) TS ( = • 2
MO
(12-25)
dT 2.769 C p dt s
where MO = allowable mass of the reactor mixture charge (kg) to limit the venting overpressure to PP (psig) DP = 10 inches PS = relief device set pressure = 20 psig PP = maximum venting pressure = 1.10(20) = 22.0 psig ∆PS = allowable venting overpressure (psi) (i.e., the maximum venting pressure minus the relief device set pressure); (22.0 – 20) = 2 psi TS = equilibrium temperature corresponding to the vapor pressure where the vapor pressure is the relief device set pressure (K); = 170°C (170 + 273.15 = 443.15 K) (dT/dt)s = reactor mixture self-heat rate (°C/min) at temperature TS (K); = 60°C/min CP = specific heat of the reactor mixture (cal/g-K ) = 0.6 cal/gm•K MO = [(102)(2.0)]/[(2.769)(60)] • (443.15/0.6)0.5 MO = 32.72 kg The density of styrene is 0.9 g/cm3. Therefore, the quantity charged in the reactor is:
(32.72) kg (10 3 ) g 1 cm 3 × × 1 kg
0.9 g
1l 1 gal × = 9.6 gal (≈ 10 gal) 3 10 cm 3.785 l 3
The reactor charge is quite small for an 800-gal reactor. If the pressure is allowed to rise to 10% above MAWP, then ∆PS = 1.1(100) – 20 = 90 psi The amount charged is:
MO =
(102 ) (90)
443.15 • 0.6 (2.769)(60)
0.5
Safety in Chemical Reaction Engineering
999
MO = 1,472.2 kg =
1, 472.2 gal (0.9)(3.785)
= 432 gal This shows that a much larger initial charge will be required. An Excel spreadsheet program (EXAMPLE12-1.xls) was developed for this example. Example 12-2
A 700-gal reactor with a net volume of 850 gal containing an organic mixture has a 10-in. rupture disk and a vent line with an equivalent length L/D = 400. The vessel MAWP is 100 psig and the rupture disk set pressure is 20 psig. A venting test that was performed showed that the reaction was “gassy.” The test mass was 30 g, the peak rate of pressure rise was 550 psi/min, and the maximum test temperature was 300°C. Determine the allowable reactor mixture charge to limit the overpressure to 10% of the MAWP. Solution Using Equation 12-30 for a “gassy” reaction, the charge amount is: 13
2 (D P )2 (M S )( PP ) M O = VP ∆PP T dP dt 2 . 07 ( ) ( ) ( T)
(12-30)
where VP = vessel total volume (gal) = 850 gal PP = maximum allowable venting pressure (psia) = 1.10 (100) + 14.7 = 124.7 psia MS = sample mass used in a DIERS test or equivalent test (g) = 30 g dP/dt = pressure rise in test (psi/sec) = 550 psi/min = 9.17 psi/sec TT = maximum temperature in test (K) = 300°C = 573.15 K ∆PP = PP – Pamb = 124.7 – 14.7 = 110 psi Pamb = ambient pressure at the end of the vent line = 14.7 psia
1000
Modeling of Chemical Kinetics and Reactor Design 13
2 (10)2 (30)(124.7) M O = (850)(110) 2.07)(573.15)(9.17) (
MO = 479.9 kg The charge amount to the reactor is 480 kg. A Microsoft Excel spreadsheet (EXAMPLE12-2.xls) was developed for this example. Example 12-3
Determine the vent size for a vapor pressure system using the following data and physical properties. Reactor Parameters: Volume, V=10 m3 Mass, M = 8,000 kg Vent opening pressure = 15 bara (217.5 psia) Temperature at set pressure Ts = 170°C (443.15 K) Overpressure allowed above operating pressure = 10% = 1 bar (105 Pa) Material Properties: Specific heat, Cp=3,000 J/kg•K Slope of vapor pressure and temperature curve dP/dT=20,000 Pa/K Rate of Reaction ∆T = dP/20,000 = 105/20,000 = 5 K Rate of set pressure, (dT/dt)s = 6.0 K/min Rate of maximum pressure = 6.6 K/min Average rate = 6.3 K/min = 0.105 K/s Solution Using Fauske’s nomograph from Figure 12-35 at a self-heat rate of 6.3 K/min and a set pressure of 217.5 psia, the corresponding vent size area per 1,000 kg of reactants = 0.0008 m2. The vent area of 8,000 kg reactants = 0.0064 m2. The vent size
Safety in Chemical Reaction Engineering
4 Area d= π
0.5
1001
= 90.27 mm (3.6 in.)
If Figure 12-35 is applicable for F = 0.5, then for F = 1.0, the area is
0.5 A = (0.0064 m 2 ) = 0.0032 m 2 1.0 The area assumes a 20% absolute overpressure. The result can be adjusted for other overpressures by multiplying the area by a ratio of 20/(new absolute percent overpressure). Using the Leung’s method and assuming L/D = 0 and F = 1.0, twophase mass flux from Equation 12-14 gives
1.0 × 443.15 G = (0.9)(1.0)(20, 000) 3, 000 kg = 6, 918.1 2 ms
0.5
Rate of heat generation: q q = Cp
dT J.K W W = 315 = (3, 000)(0.105) dt kg • K • s kg kg
From Equation 12-20, the vent area A is: A=
8, 000 × 315 0.5 10 6, 918.1 × 443.15 × 20, 000 + (3, 000 × 5.0)0.5 8, 000
2
A= 7.024 ×10–3 m2 D = 94.6 mm (3.72 in.) The vent size is about 4.0 in. Using the Fauske’s method and assuming α = 1.0, αO = 0.0, and F = 1.0, ∆P = 1 bar = 105 N/m2.
1002
Modeling of Chemical Kinetics and Reactor Design
From Equation 12-25, the vent area is
A=
1 • 2
(8, 000)(0.105)(1 − 0) 443.15 (1.0) 3, 000
0.5
(10 5 )(1 − 0)
A= 10.927 × 10-3 m2 D = 117.95 mm (4.64 in.) Example 12-4
A 3,500-gal reactor with styrene monomer undergoes adiabatic polymerization after being heated inadvertently to 70°C. The maximum allowable working pressure (MAWP) of the reactor is 5 bar absolute. Determine the relief vent diameter required. Assume a set pressure of 4.5 bara and a maximum pressure of 5.4 bara. Other data and physical properties are given as follows [12]: Data: Volume (V) Reaction mass (mo), kg Set temperature (Ts)
13.16 m3 (3,500 gal) 9,500 209.4°C = 482.5 K
Data from VSP: Maximum temperature (Tm)
219.5°C = 492.7 K
dT dt s
29.6°C/min = 0.493 K/s (sealed system)
dT dt m
39.7°C/min = 0.662 K/s
Physical property data: Vf, m3/kg Vg, m3/kg; ideal gas assumed CP, kJ/kg•K ∆HV, kJ/kg
4.5 bar set 0.001388 0.08553 2.470 310.6
5.4 bar set 0.001414 0.07278 2.514 302.3
Safety in Chemical Reaction Engineering
1003
Solution The heating rate q is determined by Equation 12-22 q=
dT 1 dT C V + 2 dt dt m s
(12-22)
Assuming CV = CP:
q=
1 (2.470 kJ kg • K)[0.493 + 0.662](K s) 2
= 1.426
kJ kg • s
The mass flux through the relief G is given by Equation 12-12, assuming L/D = 0 and ψ = 1.0
G=
∆H V Qm = 0.9ψ A υ fg
gC C P TS
0.5
(12-12)
(0.9)(1.0)(310, 660 J kg)[1(Nm) J] [1(kg m s2 ) N] G= (0.08553 − 0.001388) m 3 kg (2, 470 J kg K )(482.5 K )[1(Nm) J] = 3, 043.81
0.5
kg m 2s
The relief area is determined by Equation 12-21
A=
MOq 0.5 ∆ H V 0.5 V G + (C V ∆T ) M O υ fg
2
The change in temperature ∆T is Tm – Ts
(12-21)
1004
Modeling of Chemical Kinetics and Reactor Design
∆T = 492.7 – 482.5 = 10.2 K
A=
(9, 500 kg)(1, 426 J kg • s)[1(Nm) J] 0.5 3 310, 660 J kg 1( Nm ) J [ ] m 13 16 . 0.08414 m 3 kg 9, 500 kg (3, 043.81 kg m 2s) 0.5 J + 2, 470 kg • K (10.2 K )[1( Nm ) J ]
2
A = 0.0839 m2 The required relief diameter is 4A d= π
0.5
( 4)(0.0839 m 2 ) = 3.14
0.5
= 0.327 m
d = 327 mm (12.87 in.) The following considers a situation that involves all vapor relief. The size of a vapor phase rupture disk required is determined by assuming that all of the heat energy is absorbed by the vaporization of the liquid. At the set temperature, the heat release rate q is
dT kJ K q = C V = 2.470 0.493 dt s kg • K s
q = 1.218
kJ kg • s
The vapor mass flow through the relief is then
Safety in Chemical Reaction Engineering
Qm =
=
1005
q mo ∆H v
(1, 218 J kg) (9, 500 kg) (310, 660 J kg)
= 37.25
kg s
The required relief area for vapor is determined by γ +1 R T Q g 2 γ −1 A= m C o P γg c M γ + 1
where Qm Co A P γ gc M Rg T
= = = = = = = = =
0.5
discharge mass flow, kg/s discharge coefficient area of discharge absolute upstream pressure heat capacity ratio for the gas gravitational constant molecular weight of the gas (M = 104 for styrene) ideal gas constant (8,314 Pa m3/kg mol K) absolute temperature of the discharge
Assuming Co = 1 and γ = 1.32 A=
(37.25 kg s)
(1.0)(4.5 bar )(10 5 Pa bar )[1(N m 2 ) Pa ]
[
(8, 314 Pa m 3 kg − mol)( 482.5 K ) 1( N m 2 ) Pa × (1.32) 1( kg m s2 ) N (104 kg kg − mol)
[
A = 0.0242 m2
]
]
0.5
2.32 2 −0.32 × 2.32
0.5
1006
Modeling of Chemical Kinetics and Reactor Design
The relief diameter = 0.176 m d = 176 mm (6.9 in.) Thus, the size of the relief device is significantly smaller than for two-phase flow. Sizing for all vapor relief will undoubtedly give an incorrect result, and the reactor would be severely tested during this runaway occurrence. Table 12-7 gives the results of the VENT software program of Example 12-4. Example 12-5
(1) Show that in a continuous flow stirred tank reactor the critical temperature above which heat is generated faster than it can be removed is of the form TM − TC =
2 RTM E
where TM = the temperature at which heat is produced faster than it can be removed, K TC = coolant temperature, K Table12-7 Vent sizing for two-phase (runaway reactions) flow vent sizing for a tempered system
Safety in Chemical Reaction Engineering
1007
E = activation energy, cal/gmol R = gas law constant, cal/gmol•K (2) If the reaction has an activation energy of 30,000 cal/gmol and the cooling water is 15°C, determine the maximum temperature the reaction can operate under without reaching the runaway condition. Solution k (1) Assuming a first order exothermic reaction (A → Products) in a CFSTR with the inlet and outlet flows controlled at steady and equal rates, the rate at which energy is generated is given by
Qg =
− ∆H R (− rA ) VR a
(6-115)
The rate of reaction is given by
(− rA ) = kC A where Qg (–∆HR/a) kO CA VR E R T
= = = = = = = =
= kO
−E RT e
CA
(12-43)
rate of heat generation, cal/sec heat of reaction, cal/g-mol frequency factor, sec–1 concentration of reaction, g-mol/dm3 reaction volume, dm3 activation energy, cal/gmol gas constant, 1.987 cal/gmol•K absolute temperature, K
Substituting Equation 12-43 into Equation 6-115 gives −E
− ∆H R Qg = k C e RT VR a O A
(12-44)
Because the reaction is exothermic, heat must be removed from the reactor to keep the temperature from increasing out of control. The heat transfer rate of removal is: Qr = UA(T – TC)
(12-45)
1008
Modeling of Chemical Kinetics and Reactor Design
where Qr = U = A= TC =
rate of heat removal, cal/sec overall heat transfer coefficient, cal/cm2•sec•K heat transfer area, cm2 coolant temperature, K
If heat can be removed as fast as it is generated by the reaction, the reaction can be kept under control. Under steady state operating conditions, the heat transfer rate will equal the generation rate (see Figure 6-26). If the heat removal rate Qr is less than the heat generation rate Qg (e.g., a condition that may occur because of a cooling water pump failure), a temperature rise in the reactor is experienced. The net rate of heating of the reactor content is the difference between Equations 12-44 and 12-45. Q n = Qg – Q r Qn =
(12-46) −E
− ∆H R k O C A e RT VR − UA (T − TC ) a
(12-47)
If Qn is positive, the reaction will have an increasing temperature. If the rate of increase of Qn is positive (i.e., dQn/dT > 0), the reaction has the potential to accelerate and become uncontrollable. From Equation 12-47, C1 =
− ∆H R k O C A VR a
and C2 = UA. Equation 12-47 then becomes −E
Q n = C1e RT − C 2 (T − TC )
(12-48)
If Qn > 0 and dQn/dT > 0, the reaction has the potential to runaway. Therefore, −E
dQ n E RT = C1 − C2 > 0 e RT 2 dT
(12-49)
Safety in Chemical Reaction Engineering
1009
At the point where Qg = Qr (i.e., when the reaction begins to go out of control), T = Tm, the maximum temperature for reaction control, which yields,
C1e
−E RTM
= C 2 (TM − TC )
(12-50)
Therefore, E C 2 (TM − TC ) = C2 2 RTM
(12-51)
Rearranging Equation 12-51 gives TM − TC =
2 RTM E
(12-52)
(2) The maximum temperature TM in which the reaction can operate without reaching the runaway condition is given by Equation 12-52. Thus, for E = 30,000 cal/gmol, TC = 15°C = 288.15 K and R = 1.987 cal/gmol•K,
TM − 288.15 =
2 1.987 TM cal gmol • K2 • or 30, 000 gmol • K cal
2 TM − 15, 098 TM + 4, 350, 528 = 0
(12-53)
Equation 12-53 is a quadratic equation of the form aX2 + bX + c = 0, and the roots are: X=
−b ±
b 2 − 4ac 2a
The plausible root is X=
−b −
b 2 − 4ac 2a
1010
Modeling of Chemical Kinetics and Reactor Design
The maximum temperature TM = 293.87 K (20.72°C). Therefore, for any temperature greater than 293.87 K or 20.72°C, the reactor will begin to generate heat faster than the heat can be removed and the reaction can runaway. An approximate 6°C-temperature rise is assumed safe. To ensure safe operation, the followings actions should be taken: • Reduce the feed rate of the reactant. • Provide adequate emergency venting for the reactor. • Inject an inhibitor into the reactor or quench the reaction when it begins to go out of control. • Add diluents to reduce the reaction rate. These can be separated from the products afterwards. • Increase the size of the heat exchanger so that all the energy can be removed.
GLOSSARY Accumulation: The buildup of unreacted reagent or intermediates, usually associated with reactant added during semi-batch operations. Activation energy Ea: The constant Ea in the exponential part of the Arrhenius equation, associated with the minimum energy difference between the reactants and an activated complex (transition state that has a structure intermediate to those of the reactants and the products), or with the minimum collision energy between molecules that is required to enable a reaction to occur. Adiabatic: A system condition in which no heat is exchanged between the chemical system and its environment. Adiabatic induction time: Induction period or time to an event (spontaneous ignition, explosion, etc.) under adiabatic conditions, starting at operating conditions. Adiabatic temperature rise: Maximum increase in temperature that can be achieved. This increase occurs when the substance or reaction mixture decomposes or reacts completely under adiabatic conditions. The adiabatic temperature rise follows from: ∆Tadia = xo (∆HRX)/Cφ
Safety in Chemical Reaction Engineering
1011
where xo = initial mass fraction; ∆HRX = heat of reaction, J/kg; C = liquid heat capacity J/kg•K; φ = dimensionless thermal inertial factor (Phi-factor). Autocatalytic reaction: A reaction, the rate of which is increased by the catalyzing effect of its reaction products. Autoignition temperature: The autoignition temperature of a substance, whether solid, liquid, or gaseous, is the minimum temperature required to initiate or cause self-sustained combustion (e.g., in air, chlorine, or other oxidant) with no other source of ignition. Back pressure: The static pressure existing at the outlet of a pressure relief device as a result of the pressure in the discharge system. It is the sum of the superimposed and built-up back pressure. Blowdown: The difference between actual popping pressure of a pressure relief valve and actual re-seating pressure expressed as a percentage of set pressure. Blowdown pressure: The value of decreasing inlet static pressure at which no further discharge is detected at the outlet of a safety relief valve of the resilient disk type after the valve has been subjected to a pressure equal to or above the popping pressure. Boiling-Liquid-Expanding-Vapor-Explosive (BLEVE): The violent rupture of a pressure vessel containing saturated liquid/vapor at a temperature well above its atmospheric boiling point. The sudden decrease in pressure results in explosive vaporization of a fraction of the liquid and a cloud of vapor and mist, with accompanying blast effects. The resulting flash vaporization of a large fraction of the liquid produces a large cloud. If the vapor is flammable and an ignition source is present at the time of vessel rupture, the vapor cloud burns in the form of a large rising fireball. Built-up back pressure: Pressure existing at the outlet of a pressure relief device caused by flow through that particular device into a discharge system. Burst pressure: The value of inlet static pressure at which a rupture disc device functions. Chatter: The abnormal rapid, reciprocating motion of the movable parts of a pressure relief valve in which the disk contacts the seat.
1012
Modeling of Chemical Kinetics and Reactor Design
Combustible: A term used to classify certain liquids that will burn on the basis of flash points. Both the National Fire Protection Association (NFPA) and the Department of Transportation (DOT) define “combustible liquids” as having a flash point of 100°F (37.8°C) or lower. Condensed phase explosion: An explosion that occurs when the fuel is present in the form of a liquid or solid. Confined explosion: An explosion of a fuel-oxidant mixture inside a closed system (e.g., a vessel or building). Confined Vapor Cloud Explosion (CVCE): A condensed phase explosion occurring in confinement (equipment, building and/or congested surroundings). Examples of CVCE include explosions in vessels and pipes and processing or storing reactive chemicals at elevated conditions. The excessive buildup of pressure in the confinement results in this type of explosion leading to high overpressure, shock waves, and heat load (if the chemical is flammable and ignites). The fragments of exploded vessels and other objects hit by blast waves, become airborne, and act as missiles. Containment: A physical system in which no reactants or products are exchanged between the system and its environment under any conditions. Decomposition energy: The maximum amount of energy that can be released upon decomposition. The product of decomposition energy and total mass is an important parameter for determining the effects of a sudden energy release (e.g., in an explosion). Deflagration: The chemical reaction of a substance in which the reaction front advances into the unreacted substance at less than sonic velocity. Where a blast wave is produced that has the potential to cause damage, the term “explosive deflagration” is used. Detonation: A release of energy caused by an extremely rapid chemical reaction of a substance in which the reaction front advances into the unreacted substance at equal to or greater than sonic velocity. Design Institute for Emergency Relief Systems (DIERS): Institute under the auspices of the American Institute of Chemical Engineers funded to investigate design requirements for vent lines in the case of two-phase venting. Disk: Is the pressure containing movable element of a pressure relief valve that effects closure.
Safety in Chemical Reaction Engineering
1013
Dow Fire and Explosion Index (F&EI): A method (developed by Dow Chemical Company) for ranking the relative fire and explosion risk associated with a process. Analysts calculate various hazard and explosion indexes using material characteristics and process data. Exotherm: A reaction is called exothermic if energy is released during the reaction. Explosion: A release of energy that causes a pressure discontinuity or blast wave. Explosions in the storage or process units can be categorized in three main groups, according to mode of occurrence and damage potential. These explosions are initiated either by the thermal stratification of the liquid and vapor or by such high explosion shock waves, which have sufficient strength to rupture the reaction/storage vessels or conduits. An explosion may or may not be accompanied with fire; it depends on the type of explosion and the chemical involved in the explosion. Explosion rupture disk device: A rupture disk device designed for use at high rates of pressure rise. Fail-safe: Design features that provide for the maintenance of safe operating conditions in the event of a malfunctioning control device or an interruption of an energy source (e.g., direction of failure of a motor-operated valve on loss of motor power). Failure: An unacceptable difference between expected and observed performance. Fire point: The temperature at which a material continues to burn when the ignition source is removed. Flammability limits: The range of gas or vapor compositions in air that will burn or explode if a flame or other ignition source is present. Important: The range represents an unsafe gas or vapor mixture with air that may ignite or explode. Generally, the wider the range the greater the fire potential. Flammable: A “flammable liquid” is defined as a liquid with a flash point below 100°F (37.8°C). Flammable liquids provide ignitable vapor at room temperatures and must be handled with caution. Flammable liquids are Class 1 liquids and are subdivided as follows: Class 1A: Those having flash points below 73°F and having a boiling point below 100°F.
1014
Modeling of Chemical Kinetics and Reactor Design
Class 1B: Those having flash points below 73°F and having a boiling point at or above 100°F. Flares: Flares are used to burn the combustible or toxic gas to produce combustion products, which are neither toxic nor combustible. The diameter of a flare must be suitable to maintain a stable flame and prevent a blowdown (when vapor velocities are greater than 20% of the sonic velocity). Flash fire: The combustion of a flammable vapor and air mixture in which flame passes through that mixture at less than sonic velocity, such that negligible damaging overpressure is generated. Flash point: The lowest temperature at which vapors above a liquid will ignite. The temperature at which vapor will burn while in contact with an ignition source, but which will not continue to burn after the ignition source is removed. Gassy system: In gassy systems, the pressure is due to a permanent gas that is generated by the reaction. Hazard: An inherent chemical or physical characteristic that has the potential for causing damage to people, property, or the environment. Hazard analysis: The identification of undesired events that lead to the materialization of a hazard, the analysis of the mechanisms by which these undesired events could occur, and usually the estimation of the consequences. Hazard and Operability Study (HAZOP): A systematic qualitative technique to identify process hazards and potential operating problems using a series of guide words to study process deviations. A HAZOP is used to question every part of the process to discover what deviations from the beginning of the design can occur and what their causes and consequences may be. This is done systematically by applying suitable guide words. This is a systematic detailed review technique for both batch and continuous plants, which can be applied to new or existing processes to identify hazards. Hazardous chemical reactivity: Any chemical reaction with the potential to exhibit an increase in temperature and/or pressure too high to be absorbed by the environment surrounding the system. These include both reactive and unstable materials.
Safety in Chemical Reaction Engineering
1015
Hybrid mixture: A suspension of dust in air/vapor. Such mixtures may be flammable below the lower explosive limit of the vapor and can be ignited by low energy sparks. Hybrid system: Hybrid systems are those in which the total pressure is due to both vapor pressure and permanent gas. Inherently safe: A system is inherently safe if it remains in a nonhazardous situation after the occurrence of non-acceptable deviations from normal operating conditions. Inhibition: A protective method where the reaction can be stopped by an addition of another material. Interlock system: A system that detects out-of-limits or abnormal conditions or improper sequences and either halts further action or starts corrective action. Isothermal: A system condition in which the temperature remains constant. This implies that temperature increases and decreases that would otherwise occur are compensated for by sufficient heat exchange with the environment of the system. Likelihood: A measuring of the expected frequency which an event occurs. This may be expressed as a frequency (e.g., events per year), a probability of occurrence during a time interval (e.g., annual probability), or a conditional probability (e.g., probability of occurrence, given that a precursor event has occurred). Lower Explosive Limit (LEL) or Lower Flammable Limit (LFL): The lowest concentration of a vapor or gas (the lowest percentage of the substance in air) that will produce a flash of fire when an ignition source (heat, arc, or flame) is present. Maximum Allowable Working Pressure (MAWP): The maximum allowed pressure at the top of the vessel in its normal operating position at the operating temperature specified for that pressure. Mitigation: The lessening of the risk of an accidental event. A sequence of action on the source in a preventive manner by reducing the likelihood of occurrence of the event, or in a protective manner by reducing the magnitude of the event and for the exposure of local persons or property. Onset temperature: The temperature at which the heat released by a reaction can no longer be completely removed from the reaction vessel
1016
Modeling of Chemical Kinetics and Reactor Design
and, consequently, results in a detectable temperature increase. The onset temperature depends on detection sensitivity, reaction kinetics, vessel size, and on cooling, flow, and agitation characteristics. Oxidant: Any gaseous material that can react with a fuel (either gas, dust, or mist) to produce combustion. Oxygen in air is the most common oxidant. Overpressure: A pressure increase over the set pressure of the relief device, usually expressed as a percentage of gauge set pressure. Phi-factor, φ: A correction factor that is based on the ratio of the total heat capacity (mass × specific heat) of a vessel and the total heat capacity of the vessel contents. φ=
Heat capacity of sample + Heat capacity of vessel Heat capacity of sample
The φ factor enables temperature rises to be corrected for heat lost to the container or vessel. The φ factor approaches the value of one for large vessels and for extremely low-mass vessels. Pressure relief device: A device designed to open to prevent a rise of internal fluid pressure in excess of a specified value due to exposure to emergency or abnormal conditions. It may also be designed to prevent excessive internal vacuum. It may be a pressure relief valve, a non-reclosing pressure relief device, or a vacuum relief valve. Process safety: A discipline that focuses on the prevention of fires, explosions, and accidental chemical releases at chemical process facilities. Excludes classic worker health and safety issues involving working surfaces, ladders, protective equipment, etc. Purge gas: A gas that is continuously or intermittently added to a system to render the atmosphere nonignitable. The purge gas may be inert or combustible. Quenching: Rapid cooling from an elevated temperature (e.g., severe) cooling of the reaction system in a short time (almost instantaneously), which “freezes” the status of a reaction and prevents further decomposition. Relieving pressure: A set pressure plus overpressure. Risk: The likelihood of a specified undesired event occurring within a specified period or in specified circumstances.
Safety in Chemical Reaction Engineering
1017
Risk analysis: A methodical examination of a process plant and procedure that identifies hazards, assesses risks, and proposes measures that will reduce risks to an acceptable level. Runaway: A thermally unstable reaction system, which shows an accelerating increase of temperature and reaction rate. The runaway can finally result in an explosion. Rupture disk device: A non-reclosing pressure relief device actuated by inlet static pressure and designed to function by the bursting of a pressure containing disk. Safety relief valve: A pressure relief valve characterized by rapid opening pop action or by opening generally proportional to the increase in pressure over the opening pressure. It may be used for either compressible or incompressible fluids, depending on design, adjustment, or application. Set pressure: The inlet pressure at which the relief device is set to open (burst). Stagnation pressure: The pressure that would be observed if a flowing fluid were brought to rest along an isentropic path. Superimposed back pressure: The static pressure existing at the outlet of a pressure relief device at the time the device is required to operate. It is the result of pressure in the discharge system from other sources. Temperature of no-return: Temperature of a system at which the rate of heat generation of a reactant or decomposition slightly exceeds the rate of heat loss and possibly results in a runaway reaction or thermal explosion. Thermally unstable: Chemicals and materials are thermally unstable if they decompose, degrade, or react as a function of temperature and time at or about the temperature of use. Thermodynamic data: Data associated with the aspects of a reaction that are based on the thermodynamic laws of energy, such as Gibbs’ free energy, and the enthalpy (heat) of reaction. Time to maximum rate (TMR): The time taken for a material to selfheat to the maximum rate of decomposition from a specific temperature. Unconfined Vapor Cloud Explosion (UCVE): Occurs when a sufficient amount of flammable material (gas or liquid having high vapor
1018
Modeling of Chemical Kinetics and Reactor Design
pressure) is released and mixes with air to form a flammable cloud such that the average concentration of the material in the cloud is higher than the lower limit of explosion. The resulting explosion has a high potential of damage as it occurs in an open space covering large areas. The flame speed may accelerate to high velocities and produce significant blast overpressure. Vapor cloud explosions in densely packed plant areas (pipe lanes, units, etc.) may show accelerations in flame speeds and intensification of blast. Upper Explosive Limit (UEL) or Upper Flammable Limit (UFL): The highest concentration of a vapor or gas (the highest percentage of the substance in the oxidant) that will produce a flash or fire when an ignition source (heat, arc, or flame) is present. Vapor specific gravity: The weight of a vapor or gas compared to the weight of an equal volume of air, which expresses of the density of the vapor or gas. Materials lighter than air have vapor specific gravity less than 1.0 (e.g., acetylene, methane, hydrogen). Materials heavier than air (e.g., ethane, propane, butane, hydrogen, sulphide, chlorine, sulfur dioxide) have vapor specific gravity greater than 1.0. Vapor pressure: The pressure exerted by a vapor above its own liquid. The higher the vapor pressure, the easier it is for a liquid to evaporate and fill the work area with vapors that can cause health or fire hazards. Vapor pressure system: A vapor pressure system is one in which the pressure generated by the runaway reaction is solely due to the increasing vapor pressure of the reactants, products, and/or solvents as the temperature rises. Venting (emergency relief): Emergency flow of vessel contents out of the vessel. The pressure is reduced by venting, thus avoiding a failure of the vessel by overpressurization. The emergency flow can be one-phase or multiphase, each of which results in different flow and pressure characteristics. Multiphase flow (e.g., vapor and or gas/ liquid flow) requires substantially larger vent openings than singlephase vapor (and/or gas) flow for the same depressurization rate.
REFERENCES 1. Barton, J. A. and Nolan, P. F. “Incidents in the Chemical Industry due to Thermal-runaway Chemical Reactions, Hazards X; Process
Safety in Chemical Reaction Engineering
2. 3.
4. 5. 6.
7.
8.
9.
10.
11.
12. 13.
14.
1019
Safety in Fine and Speciality Chemical Plants,” IChemE, Symp., Ser. No. 115 pp. 3–18, 1989. Shabica, A. C., “Evaluating the Hazards in Chemical Processing,” Chem. Eng. Prog., Vol. 59, No. 9, pp. 57–66, 1963. Mumford, C. J., “PSI Chemical Process Safety,” Occupational Health and Safety Training Unit, University of Portsmouth Enterprise Ltd., version 3, 1993. Wells, G., Major Hazards and Their Managements, Institution of Chemical Engineer (IChemE), 1997. Barton, J. and Rogers, R., Chemical Reaction Hazards, 2nd ed., Institution of Chemical Engineers, 1997. Townsend, D. I. and Tou, J. “Thermal Hazard Evaluation by an Accelerating Rate Calorimeter,” Thermochimica Acta, 27, pp. 1–30, 1980. Grolmes, M. A., “Pressure Relief Requirement for Organic Peroxides and Other Related Compounds,” Int. Symp. on Runaway Reactions, Pressure Relief Design and Effluent Handling, AIChE, pp. 219–245, March 11–13, 1998. Fauske, H. K., Clare, G. H., and Creed, M. J., “Laboratory Tool for Characterizing Chemical Systems,” Proceeding of the Int. Symp. on Runaway Reactions, AIChE/CCPS, Boston, MA, March 7–9, 1989. Leung, J. C., Fauske, H. K., and Fisher, H. G., “Thermal Runaway Reactions in a Low Thermal Inertia Apparatus,” Thermochimica Acta, 104, pp. 13–29, 1986. Ahmed, M., Fisher, H. G., and Janeshek, A. M., “Reaction Kinetics from Self-heat Data Correction for the Depletion of Sample,” Proceeding of the Int., Symp. on Runaway Reactions, AIChE/ CCPS, Boston, MA, March 7–9, 1989. Wilberforce, J., “The Use of the Accelerating Rate Calorimeter to Determine the SADT of Organic Peroxides,” ARC technical document, 1981. Huff, J., “Emergency Venting Requirements,” Plant/Operations Progress, 1 (4), pp. 211–219, 1982. Townsend, D., Ferguson, H., and Kohlbrand, H., “Application of ARC™ Thermokinetic Data to the Design of Safety Schemes for Industrial Reactors,” Process Safety Progress, 14 (1), pp. 71–76, 1995. Gustin, J. L., “Choice of Runaway Reaction Scenarios for Vent Sizing Based on Pseudo-adiabatic Calorimetric Techniques,” Int. Symp. on Runaway Reaction, Pressure Relief Design, and Effluent Handling, AIChE, pp. 11–13, 1998.
1020
Modeling of Chemical Kinetics and Reactor Design
15. Creed, M. J. and Fauske, H. K., “An Easy Inexpensive Approach to the DIERS Procedure,” Chem. Eng. Prog., 86 (3), 45, 1990. 16. Fauske, H. K., “The Reactive System Screen Tool (RSST): An Easy, Inexpensive Approach to the DIERS Procedure,” Int. Symp. on Runaway Reaction, Pressure Relief Design, and Effluent Handling, AIChE, pp. 51–63, March 11–13, 1998. 17. Singh, J., “PHI-TEC: Enhanced Vent Sizing Calorimeter Application and Comparison with Existing Devices,” Proceeding of the Int. Symp. on Runaway Reactions, AIChE/CCPS, pp. 313–330, Boston, MA, March 7–9, 1989. 18. Waldram, S. P., “Toll Manufacturing: Rapid Assessment of Reactor Relief Systems for Exothermic Batch Reactions,” Hazards XII European Advances in Process Safety, IChemE, Symp., Series No. 134, pp. 525–540, 1994. 19. Singh, J., “Vent Sizing for Gas-Generating Runaway Reactions,” J., Loss Prev. Process Ind., Vol. 7, No. 6, pp. 481–491, 1994. 20. Singh, J., “Batch Runaway Reaction Relief: Re-evaluation of ‘credible’ Scenario,” Process Safety Prog., Vol. 16, No. 4, pp. 255–261, 1997. 21. Coker, A. K., “Size Relief Valves Sensibly Part 2,” Chem. Eng. Prog., pp. 94–102, November 1992. 22. Gibson, N., Maddison, N., and Rogers, R. L., “Case Studies in the Application of DIERS Venting Methods to Fine Chemical Batch and Semi-batch reactors, Hazards from Pressure: Exothermic Reactions, Unstable Substances, Pressure Relief and Accidental Discharge,” IChemE, Symp, Ser. No. 102, EFCE Event No. 359, pp. 157–169, 1987. 23. Ritcher, S. H. and Turner, F., “Properly Program the Sizing of Batch Reactor Relief Systems, Chem. Eng. Prog., pp. 46–55, 1996. 24. Fisher, H., et al., “Emergency Relief System Design Using DIERS Technology,” AIChE’s Design Institute for Emergency Relief Systems, DIERS, AIChE, New York, 1992. 25. Boyle, W. J., “Sizing Relief Area for Polymerization Reactors,” Chem. Eng. Prog., 63 (8), p. 61, 1967. 26. Huff, J. E., CEP Loss Prevention Technical Manual, 7, 1973. 27. Fisher, H. G., “An Overview of Emergency Relief System Design Practice,” Plant/Operations, Prog., 10 (1), pp. 1–12, January 1991. 28. Leung, J. C., “Simplified Vent Sizing Equations for Emergency Relief Requirements in Reactors and Storage Vessels, AIChE Journal, Vol. 32, No. 10, pp. 1622–1634, 1986.
Safety in Chemical Reaction Engineering
1021
29. Fauske, H. K., “Generalized Vent Sizing Monogram for Runaway Chemical Reactions, Plant/Operation, Prog., Vol. 3, No. 3, October 1984. 30. Crowl, D. A. and Louvar, J. F., Chemical Process Safety Fundamental with Applications, Prentice-Hall, Inc., New Jersey, 1990. 31. Leung, J. C. and Fauske, H. K., Plant/Operation Progress, 6 (2), pp. 77–83, 1987. 32. Fauske, H. K., “Emergency Relief System Design for Runaway Chemical Reaction: Extension of the DIERs Methodology, Chem. Eng. Res. Des., Vol. 67, pp. 199–202, 1989. 33. Noronha, J. A., Seyler, R. J., and Torres, A. J., “Simplified Chemical Equipment Screening for Emergency Venting Safety Reviews Based on the DIERS Technology,” Proceedings of the Int. Symp. on Runaway Reactions, pp. 660–680, Cambridge, MA, March 7–9, 1989. 34. Duxbury, H. A. and Wilday, A. J., “The Design of Reactor Relief System,” Trans. IChemE., Vol. 68, Part B, pp. 24–30, February 1990. 35. Coker, A. K., “Computer Program Enhances Guidelines for GasLiquid Separator Designs,” Oil & Gas Journal, May 1993. 36. American Petroleum Institute Recommended Practice 521, “Guide for Pressure-Relieving and Depressurizing Systems,” 2nd ed., 1982. 37. Less, F. P., Loss Prevention in the Process Industries, 2nd ed., Butterworth-Heinemann, 1996. 38. Wells, G. L., Safety in Process Plant Design, John Wiley & Sons, New York, 1980. 39. Grossel, S. S., “Design and Sizing of Knock-out Drums/Catchtanks for Reactor Emergency Relief Systems,” Plant/Operations Prog., Vol., 5, No. 3, pp. 129–135, 1986. 40. Parry, C. F., Relief Systems Handbook, Institution of Chemical Engineers, 1992. 41. Coker, A. K., “Size Relief Valves Sensibly,” Chem. Eng. Prog., pp. 20–27, 1992. 42. Englund, S. M., “Inherently Safer Plants, Practical Applications,” Process Safety Prog., Vol. 14, No. 1, pp. 63–70, 1995. 43. Kletz, T., “Friendly Plants,” Chem. Eng. Prog., pp. 18–26, 1989. 44. Kletz, T., “Hazop and Hazan—Identifying and Assessing Process Industry Hazards,” 4th ed., IChemE, 1999.
B. Oxidations 1. Hydrogen peroxidedil ute aqueous 2. Air or I2 (mercaptan to disulfide) 3. Oppenauer 4. Selenium dioxide 5. Aqueous solution nitric acid, permanganate, manganic dioxide, chromic acid, dichromate
A. Reductions 1. Clemmensen 2. Sodium-amalgam 3. Zinc-acetic acid 4. Zinc-hydrochloric acid 5. Zinc-sodium hydroxide 6. Ferrous ammonium sulfate 7. Lead tetraacetate 8. Meerwein-Pondorff 9. Lithium aluminum hydride 10. Dialkyl aluminum hydride 11. Rosenmund 12. Catalytic high pressure 13. Catalytic low pressure
Reaction
E
E D D D
D D E E E E E D B B A A B
Degree of hazard Reaction
H. Simple metathetical replacements
G. Hydrolysis, aqueous nitriles, esters
Table 12-8 Hazard rating chemical reactions
CHAPTER 12: APPENDIX
D
E
Degree of hazard
1022 Modeling of Chemical Kinetics and Reactor Design
B A D A A C D E C
Carbon-oxygen 1. Williamson 2. Formaldehyde-hydrochloric acid 3. Ethylene oxide.
E C D C E E B
A B C C
B C A A
C. Alkylations: Carbon-carbon 1. Jarousse 2. Alkali metal 3. Alkali metal alcoholate 4. Alkali metal amides and hydrides 5. Reformatsky 6. Michael 7. Grignard 8. Organo metallics, such as dialkyl zinc or cadmiun-alkyl or aryl lithium 9. Alkali acetylides 10. Diels-Alder 11. Arndt-Eistert 12. Diazoalkane and aldehyde. 13. Aldehydes or ketones and hydrogen cyanide
Electrolytic Chromyl chloride Ozonolysis Nitrous acids Peracids-low molecular weight or two or more positive groups 11. Peracids-high molecular weight 12. t-butyl hypochlorite 13. Chlorine
6. 7. 8. 9. 10.
J. Pyrolysis 1. Atmospheric pressure 2. Pressure
I. Preparation and reaction of peroxides I. and peracids 1. Concentrated 2. Dilute
D B
A D
Safety in Chemical Reaction Engineering 1023
D. Condensations 1. Erlenmeyer 2. Perkin 3. Acetoacetic ester 4. Aldol 5. Claisen 6. Knoevenagel 7. Condensations using catalysts such as phosphoric acid; AlCl3; KHSO4; SnCl4; H2SO4; ZnCl2; NaHSO3; POCl3; HCl; FeCl3 8. Acyloin 9. Diketones with hydrogen sulfide
Carbon-nitrogen 1. Cyanomethylation 2. Chloromethylation 3. Ethylenimine 4. Ethylene oxide 5. Quarternization
4. Dialkyl sulfate 5. Diazoalkane
Reaction
E C C
D D D D D D
C D C C D
D A
Degree of hazard
Table 12-8 (continued)
L. Mannich reaction
K. Schmidt reaction
Reaction
D
B
Degree of hazard
1024 Modeling of Chemical Kinetics and Reactor Design
Diketones with Diamines—quinazolines Diketones with NH2OH—isoxazolines Diketones with NH2NH2—pyrazoles Diketones with semi-carbazide—pyrazoles Diketones with ammonia—pyrazoles Carbon disulfide with aminoacetamide—thiazolone Nitriles and ethylene diamines—imidazolines
D E D D D A A
E B
B E C
D D D D D A D
N. Nitrations 1. Dilute 2. Concentrated
M. Halogenations SO2X2, SOX2, SX POX3, PX3, HX Cl2, Br2
D B
D D C
Source: A. C. Shabica, Chem. Eng. Prog., Vol. 59, No. 9, Reproduced with permission of the AIChE. Copyright © 1963. All rights reserved.
F. Esterifications 1. Inorganic 2. Alkoxy magnesium halides 3. Organics: Alcohol and acids or acid chlorides or acid anhydride Alkyl halide and silver salts of acids Alkyl sulfate and alkali metal salt of acids Alkyl chlorosulfates and alkali salts of carboxylic acid Ester-exchange Carboxylic acid and diazomethane Acetylene and carboxylic acid-vinyl ester
E. Aminations 1. Liquid ammonia 2. Aqueous ammonia 3. Alkali amides
10. 11. 12. 13. 14. 15. 16.
Safety in Chemical Reaction Engineering 1025
Hydrogen (high pressure) Hydrogen peroxide (< 35% water) Iodine azide Lead azide Manganese heptoxide Mannitol hexanitrate Mercury acetylide Mercury azide Methyl isocyanide Nitrocellulose, dry Ozonides (dry) Parathion Perchloric acid (less than 10% water)
Phenyl diazosulfide Picric acid and Cu, Pb and Zn salts, (dry) Radio isotopes, gamma emitters Silver azide Tetracene Tetracetylene dicarbonic acid Tetranitromethane Trinitroaniline Trinitrobenzene Trinitrochlorbenzene 2, 4, 6 trinitro-m- cresol Trinitrotoluene 2, 4, 6-trinitroxylene Zinc peroxide
Ethyl nitrite Hyponitrous acid Mercuric perchlorate Methyl nitrite Methyl phosphine Phosgene
Thionyl chloride–fluoride Thiophosgene Vinyl chloride Vinyl ether Vinylidene chloride
Acetyl benzoyl peroxide Acetylene Acetylene chloride
Furan Hydrazine, Anhydrous
Inorganic salts of alkyl nitrates Nitroso guanidine Nitrosomethyl urea (dry)
3. Special—dangerous when exposed to heat or flame may explode or is spontaneously flammable in air
Carbon disulfide Carbon monoxide Carbonoxysulfide Dibromoacetylene Diethyl ether Dimethyl ether
2. Highly dangerous—gives off highly toxic fumes on heat, flame, shock
Acetylides Acetyl peroxides Aluminum methyl Ammonium chlorate Diazoethane Diazomethane Dichloroacetylene N,N-diethyl carbanilide Ethylene oxide Formyl peroxide Fulminates Glycerol trinitrate Hexane hexanitrate
1. Hazardous—highly dangerous; will explode owing to heat, flame, shock
Table 12-9 Hazard rating substances
1026 Modeling of Chemical Kinetics and Reactor Design
Hydrazoic acid Hydrides, volatile Hydrogen cyanide (unstabilized) Hydrogen (low pressure) Hydrogen peroxide (> 35% water) Magnesium peroxide Mercurous azide Methyl acetylene Methyl lactate Nickel hypophosphite Nitriles > ethyl Nitrogen bromide Ozone Ozonides (solution) Pentaborane Perbenzoic acid Perchlorates Perchloric acid (10% or more water) Performic acid Peroxides (organic) Phosphorus (white) Phenylazoimide Silicon hydride Silver oxalate Sodium chlorite Trinitrobenzaldehyde
Acetone Alkali cyanides, hydrides, & metals Aluminum borohydride, carbide, chloride, hydride & nitride Benzoyl chloride Boron compounds Carbonyls Chlorine Cyanogen Cyanogen bromide Cyanogen chloride Diakyl carbamyl chlorides Diakyl aluminum hydrides Diborane Dibromoketone Dichloromethyl chloroformate Diphosgene Fuming nitric acid Grignard reagents Hydrides nonvolatile Hydrogen cyanide (stablized) Hydrogen fluoride
Lithium aluminum hydride Magnesium metal Nitric acid Oleum Phosphenyl Chloride Phosphides Phosphorus nitride, Oxyhalides, Penta-halides, & tri-halides Radio isotopes, beta emitters Sodium azide
4. Dangerous—will react with water or steam to produce hydrogen or toxic fumes or highly flammable gases
Alkyl ethers < C4 Allylene Aluminum chlorate Ammonium chromate Benzoyl peroxide, dry Butadiene-1,3, Chlorates Dialkyl phosphines Diazoacetic ester Diazoamidobenzol Diazobenzene chloride Diethyl carbonate Diisopropyl & higher alkyl ethers Ferrous perchlorate
Safety in Chemical Reaction Engineering 1027
Acetic Acid Acetic anhydride Acetoacetanilide Acetone cyanhydrin Acetyl chloride Acrolein Acrylonitrile Alcohols Alkaloids Alkyl & aryl acids, Alcohols, amines, Esters, ethers > C3, halides, hydrocarbons, ketones, mercaptans & sulfides Alkyl dihalides Alkyl nitrates Amino pyrine 2-amino thiazole Ammonia Ammonium nitrate. Amyl nitrite Aniline Benzene sulfonyl chloride Benzoyl peroxide (wet) Bromine & iodine N-bromo acetamide Chlorobutanol Chloroform Chloroform 2-chloro pyridine Cresols Cyanates
Epichlorohydrin Esters Ethylene imine Hydrazine hydrate Hydrogen sulfide. Hydroxylamine salts Inorganic Hg. compounds Iodates Iodides Ketone > CH3 Methyl acrylate Methylene chloride Nitriles Nitrosomethyl urea (wet) Petroleum ether Piperidine
5. Conventional—when heated to decomposition gives off highly toxic fumes and/or products that may be explosion hazards when exposed to flame
Table 12-9 (continued)
1028 Modeling of Chemical Kinetics and Reactor Design
N, N-diakyl amino Ethylamine Dibutylphosphite Dicyandiamide Diethylamino ethanol Diethyl phosphite Diethyl sulfate Diketene Charcoal Chlorphenyl carbamate. Diethylene glycol Dimethyl formamide Formic acids Hydrocarbon
Inorganic acids Methyl diacetoacetate Phenyl cellosolve Silica gel Tetradecane Tetrahydro phthalic anhydride
Propargly bromide Pyridine Sodium alkoxide Sodium azide Sodium borohydride Tetrabromoethane Tetrachloroethane
Source: A. C. Shabica, Chem. Eng. Prog., Vol. 59, No. 9, Reproduced with permission of the AIChE. Copyright © 1963. All rights reserved.
Alcohol Alkyl acids > C2 Alumina Ammonia Amyl alcohol Benzoic anhydride Benzophenone
6. Moderately stable when heated gives off acrid fumes
Allyl amine Allyl cyanide Allyl ether Allyl halide Amines Aminoacetophenone p-aminoazobenzene p-aminophenol
Safety in Chemical Reaction Engineering 1029
1030
Modeling of Chemical Kinetics and Reactor Design
Table 12-10 Toxic hazards from incompatible chemicals Substances in Column I should be stored/handled so that they cannot contact corresponding substances in Column II because toxic materials (Column III) would be produced.
Column I Arsenical materials
Column II Any reducing agent
Column III Arsine
Azides
Acids
Hydrogen azide
Cyanides
Acids
Hydrogen cyanide
Hypochlorites
Acids
Chlorine or hypocholorous acid
Nitrates
Sulfuric acid
Nitrogen dioxide
Nitric acid
Copper, brass and heavy metals
Nitrogen dioxide (nitrous fumes)
Nitrites
Acids
Nitrous fumes
Phosphorus
Caustic Alkalis or reducing agents
Phosphine
Selenides
Reducing agents
Hydrogen selenide
Sulfides
Acids
Hydrogen sulfide
Tellurides
Reducing agents
Hydrogen telluride
Source: C. J. Mumford, PS1 Chemical Process Safety, October 1993, Reproduced with permission of the Occcupational Health and Safety Training Unit, University of Portsmouth, U.K.
Chromic acid, nitric acid, hydroxyl-containing compounds, ethylene glycol, perchloric acid, peroxides, and permanganates. Concentrated nitric and sulfuric acid mixtures. Carbon dioxide, carbon tetrachloride, and other chlorinated hydrocarbons. (Also prohibit potassium, water, foam and dry chemical on fires involving these metals—dry sand should be available). Mercury, chlorine, calcium hypochlorite, iodine, bromine and hydrogen fluoride. Acids, metal powders, flammable liquids, chlorates, nitrites, sulfur, finely divided organics or combustibles. Nitric acid, hydrogen peroxide. Ammonia, acetylene, butadiene, butane and other petroleum gases, sodium carbide, turpentine, benzene, and finely divided metals. Water. Calcium hypochlorite. Ammonium salts, acids, metal powders, sulfur, finely divided organics or combustibles. Acetic acid, naphthalene, camphor, glycerol, turpentine, alcohol and other flammable liquids.
Acetone
Alkali and alkaline earth metals, eg. sodium, magnesium, calcium, powdered aluminum.
Anhydrous ammonia
Ammonium nitrate
Aniline
Bromine
Calcium oxide
Carbon, activated
Chlorates
Chromic acid and chromium trioxide
Column II
Acetic acid
Column I
Substances in Column I must be stored/handled so that they cannot contact corresponding substances in Column II under uncontrolled conditions, or violent reactions may occur.
Table 12-11 Reactive hazards with incompatible chemicals
Safety in Chemical Reaction Engineering 1031
Ammonia, acetylene, butadiene, butane and other petroleum gases, hydrogen sodium carbide, turpentine, benzene and finely divided metals. Ammonia, methane, phosphine and hydrogen sulfide. Acetylene, hydrogen peroxide Isolate from “everything” Hydrogen peroxide, nitric acid, any other oxidant Fluorine, chlorine, bromine, chromic acid, peroxide
Nitric acid, alkalis. Ammonia, aqueous or anhydrous Copper, chromium, iron, most metals or their salts, any flammable liquid, combustible materials, aniline, nitromethane. Fuming nitric acid, oxidizing gases. Acetylene, ammonia (anhydrous or aqeous). Acetylene, fulminic acid, ammonia.
Chlorine dioxide
Copper
Fluorine
Hydrazine
Hydrocarbons (benzene, butane, propane, gasoline, turpentine, etc).
Hydrocyanic acid
Hydrofluoric acid, anhydrous (hydrogen fluoride).
Hydrogen peroxide
Hydrogen sulfide
Iodine
Mercury
Column II
Chlorine
Column I
Table 12-11 (continued)
1032 Modeling of Chemical Kinetics and Reactor Design
Inorganic bases, amines. Silver, mercury. Oils, grease, hydrogen, flammable liquids, solids or gases. Acetic anhydride, bismuth and its alloys, alcohol, paper, wood, grease, oils. Acids (organic or mineral), avoid friction, store cold. Air, oxygen. Acids (see also chlorates). Acids (see also perchloric acid). Glycerol, ethylene glycol, benzaldehyde, sulfuric acid Acetylene, oxalic acid, tartaric acid, fulminic acid, ammonium compounds. See alkali metals (above) Ammonium nitrate and other ammonium salts. Any oxidisable substance, such as ethanol, methanol, glacial acetic acid, acetic anhydride, benzaldehyde, carbon disulfide, glycerol, ethylene glycol, ethyl acetate, methyl acetate and furfural. Chlorates, perchlorates, permanganates.
Nitroparaffins
Oxalic acid
Oxygen
Perchloric acid
Peroxides, organic
Phosphorus (white).
Potassium perchlorate
Potassium perchlorate
Potassium permanganate
Silver
Sodium
Sodium nitrite
Sodium peroxide
Sulfuric acid
Source: C. J. Mumford, PS1 Chemical Process Safety, October 1993, Reproduced with permission of the Occcupational Health and Safety Training Unit, University of Portsmouth, U.K.
Acetic acid, acetone, alcohol, aniline, chromic acid, hydrocynanic acid, hydrogen sulfide, flammable liquids, flammable gases, and nitratable substances, paper, cardboard and rags.
Nitric acid (conc)
Safety in Chemical Reaction Engineering 1033
1034
Modeling of Chemical Kinetics and Reactor Design
CHAPTER THIRTEEN
Scale-Up in Reactor Design INTRODUCTION Scale-up and dimensionless analysis are indispensable mathematical tools for designers engaged in industrial processes, where chemical or biochemical conversion of feeds, together with various transport processes such as momentum, mass, or heat, take place. These processes are scale-dependent implying different behavior on laboratory, model, or full-scale plants. Examples of these processes are homogeneous and heterogeneous reactions. Optimizing chemical processes often involves a deep knowledge of their physical and technical elements. The effects of each parameter that influence the process must be examined for which sometimes mathematical solutions do not exist. In such cases, the designer must depend on both model experiments and the theory of similarity between the model and the full-scale plant. This theory enhances the planning and execution of experiments and the analysis of the data to produce adequate and reliable information on the size and process parameters of the full-scale plant. Chemical reactions obey the rules of chemical kinetics (see Chapter 2) and chemical thermodynamics, if they occur slowly and do not exhibit a significant heat of reaction in the homogeneous system (microkinetics). Thermodynamics, as reviewed in Chapter 3, has an essential role in the scale-up of reactors. It shows the form that rate equations must take in the limiting case where a reaction has attained equilibrium. Consistency is required thermodynamically before a rate equation achieves success over the entire range of conversion. Generally, chemical reactions do not depend on the theory of similarity rules. However, most industrial reactions occur under heterogeneous systems (e.g., liquid/solid, gas/solid, liquid/gas, and liquid/liquid), thereby generating enormous heat of reaction. Therefore, mass and heat transfer processes (macrokinetics) that are scale-dependent often accompany the chemical reaction. The path of such chemical reactions will be 1034
Scale-Up in Reactor Design
1035
identical on a pilot plant scale and the full-scale plant if both transfer processes are similar and the chemistry is identical. Pilot plant experiments represent an essential step in the investigation of a process toward formulating specifications for a commercial plant. A pilot plant uses the microkinetic data derived by laboratory tests and provides information about the macrokinetics of a process. Examples include the interaction of large conglomerates of molecules, macroscopic fluid elements, the effects of the macroscopic streams of materials and energy on the process, as well as the true residence time in the full-scale plant. In a continuous reaction process, the true residence time of the reaction partners in the reactor plays a major role. It is governed by the residence time distribution characteristic of the reactor, which gives information on backmixing (macromixing) of the throughput. The principal objectives of studies into the macrokinetics of a process are to estimate the coefficients of a mathematical model of the process and to validate the model for adequacy. For this purpose, a pilot plant should provide the following: • Identify the flow pattern of the prototype system by subjecting it to an impulse, step, or sinusoidal disturbance by injection of a tracer material as reviewed in Chapter 8. The result is classified as either complete mixing, plug flow, and an option between a dispersion, cascade, or combined model. • Investigate and determine thermal parameters involving conditions under which heat transfer takes place and an accurate value of the heat transfer surface area. Additionally, a review of the process is required for thermal stability (see Chapter 6). • Make an accurate estimate of the effects produced by diffusion parameters and arrange the process to proceed in a kinetic or a diffusion region. The reactor efficiency is determined on the basis of the chosen model. • Investigate the system under dynamic conditions with disturbances acting over many circuits and monitor how the process variables change with time, resulting in a judicious recommendation regarding the control of the system. • Develop a mathematical model of the system, which is tested and fitted to the system with the aid of a computer. • Optimize the mathematical model with the sole aim of enhancing the performance of the system.
1036
Modeling of Chemical Kinetics and Reactor Design
The following reviews scale-up of chemical reactors, considers the dimensionless parameters, mathematical modeling in scale-up, and scale-up of a batch system.
DEVELOPMENT AND SCALE-UP OF REACTORS The objective of scale-up in reactor design is to determine a criterion or criteria on which to base the transfer of the laboratory scale into a full-scale commercial unit. Before proceeding from a laboratory to an industrial scale, additional investigations are required. However, it is difficult to define these additional steps to gather all the information as promptly as possibe and at minimum cost. The methodology of process development leading to scale-up becomes the principal factor for the success of the operation. In achieving this purpose, experiments are classified into three main types: laboratory, pilot plant, and demonstration units. In laboratory-type experiments, certain aspects of the process are investigated by handling relatively small amounts of raw materials to reduce the material constraints to a minimum. In laboratory experiments, a series of measurements are taken concerning all the mechanisms that are independent of size (thermodynamics and chemical kinetics). A number of physical properties, such as densities, viscosities, specific heats, and phase equilibria, involved in the model must be ascertained throughout the operating conditions of the process. Pilot plant experiments vary over a wide range, accounting for industrial constraints (e.g., duration of operation, control parameters, equipment reliability, and impurities in the raw materials). Scale-up problems are investigated during pilot plant experiments. A pilot plant is an experimental rig, which displays the part of the operation that corresponds to an industrial plant. It allows for simultaneous analysis of the physical and chemical mechanisms. A pilot plant is indispensable for measuring the extent of the possible interactions between these two types of mechanisms. It can be small to minimize extraneous costs such as the total operation cost as well as other constraints. Experiments at the level of a demonstration unit apply to the construction of a first industrial unit, but on a modest scale (e.g., onetenth of full-scale production). This step can be very costly, but has been proven to be indispensable.
Scale-Up in Reactor Design
1037
SIMILARITY CRITERIA Some physical processes occurring in a single phase may be scaledup using the principles of physical modeling. This is based on the criteria of geometric and chemical similarity derived from differential equations, which describe the process, or from dimensional analysis of the process variable (Chapter 7). In physical modeling, the process of interest is reproduced on different scales, and the effect of physical features and linear dimensions is analyzed. Experimental data are reduced to relationships involving dimensionless groups composed of various combinations of physical quantities and linear dimensions. The relationships can be classified into dimensionless groups or similarity criteria. Physical modeling involves searching for the same or nearly the same similarity criteria for the model and the real process. The fullscale process is modeled on an increasing scale with the principal linear dimensions scaled-up in proportion, based on the similarity principle. For relatively simple systems, the similarity criteria and physical modeling are acceptable because the number of criteria involved is limited. For complex systems and processes involving a complex system of equations, a large set of similarity criteria is required, which are not simultaneously compatible and, as a consequence, cannot be realized. The objectives are not realized when physical modeling are applied to complex processes. However, consideration of the appropriate differential equations at steady state for the conservation of mass, momentum, and thermal energy has resulted in various dimensionless groups. These groups must be equal for both the model and the prototype for complete similarity to exist on scale-up.
SCALE-UP IN RELATION TO VARIOUS FACTORS In many cases, two identical reaction systems (e.g., a pilot plant scale and a full-scale commercial plant) exhibit different performances. This difference in performance may result from different flow patterns in the reactors, kinetics of the process, catalyst performance, and other extraneous factors. As discussed in Chapters 8 and 9, the fluid elements in various reactors reside in different intervals of time and, consequently, the residence time is different. This is determined from the response curve
1038
Modeling of Chemical Kinetics and Reactor Design
of the system. Thus, if the model and the full-scale plant are to give the same yield, both should have the same residence time distribution or the same response curve. In the case of a tubular reactor, the effect of longitudinal mixing may be minimized. Additionally, a smoother velocity profile may be obtained through the use of higher flow velocities or packing. Swirl in the mixing may be avoided by providing baffles, which additionally secure hydrodynamic reproducibility (Chapter 7). In the case of exothermic or endothermic reactions, scale-up may impair conditions for heat input or removal because the ratio of the heat transfer surface area to the reactor volume is reduced. Identical conditions for heat transfer in both the model and full-scale plants may be achieved in exothermal reactions if both have the same thermal stability coefficient. This requirement is obtained by introducing external heat exchangers. Alternatively, a reactor with a strong exothermic reaction can be divided into several small size reactors. In this manner, the ratio of the external heat transfer surface area to the reactor volume is increased, thereby avoiding an excessive temperature rise in the reactor.
HEAT EFFECT The dominant feature of many reactor scale-ups is the enormous thermal effects that accompany reactions. In many reactor designs, the salient issue is that the reactor is capable of transferring adequate heat compared to attaining a certain degree of reaction. Many commercial reactors operate adiabatically, implying there is negligible heat exchange with the surroundings compared to the enormous flows of heat within the system. The heat generated or consumed by the reaction should be defined so that the temperature history of the reacting fluid is known. Temperature runaways (Chapter 12) and reduced conversions (Chapter 6) relative to that possible at equilibrium are two problems that are prevalent in exothermic reactions. In a reactor with isothermal operation, it is necessary to know how much heat is being exchanged with the surroundings to maintain isothermality. For example, consider the synthesis of ammonia at two different temperatures. Table 13-1 shows values for the heat of reaction. The negative enthalpy changes upon reaction show that the products of the reaction contain less enthalpy than did the reactants. This implies that heat must have been generated, which is characteristic of an exothermic
Scale-Up in Reactor Design
1039
Table 13-1 Heat of reaction in ammonia synthesis [1] N 2 + 3H 2
[2NH 3
∆H O 25° C = −22,100 cal mol N 2 reacted ( −92, 500 J mol )
∆H O 528° C = −25, 800 cal mol N 2 reacted ( −108, 000 J mol )
reaction. Another common feature is the decrease in the total number of moles. Conversely, reactions where the number of moles increases are usually endothermic, hence, energy must be added to the system to break the bonds. Observing changes in the total number of moles involving endothermic or exothermic reaction can assist in predicting reactor performance. However, a quantitative expression of the heat of reaction is essential and can be obtained whether or not the reaction involves a change in the total number of moles. Table 13-1 shows a negligible change in the heat of reaction over a 500°C temperature range. The enormous heat effects indicate that ammonia synthesis reactors must be designed with particular attention given to heat exchange [1].
COEFFICIENTS OF PROCESS STABILITY The scale-up of exothermic processes is greatly enhanced through the use of the coefficient of thermal stability. Kafarov [2] defined this as the ratio of the slope (tan α2) of the line representing the heat removal (due to the heat transfer medium and changes in enthalpy) to the slope (tan α1) of the line representing heat generation (by the reaction) at the intersection of the two lines when plotted on the T versus Q coordinates. This is expressed as
β=
tan α 2 tan α1
(13-1)
At β > 1, the process is stable. At β > 1, the process is unstable. Furthermore, if β* is designated as the stability of the prototype reactor and β the stability of the model, the transition stability coefficient is defined by
1040
δ=
Modeling of Chemical Kinetics and Reactor Design
β∗ β
(13-2)
At δ = 1, both the model and the prototype are similarly stable. At δ > 1, the prototype has a greater stability than the model. At δ < 1, the model has a greater stability than the prototype. In applying the transition stability coefficient for scaling up, the designer requires systematic process steps in a pilot plant scale reactor with a satisfactory performance stability over a temperature interval of interest at stable component concentrations and other variables that may be used to control the process. In heterogeneous reactions, knowledge of the process control by diffusion, kinetics, or both is essential. When a chemical process proceeds in a kinetic region, the reaction rate controls the entire process, while the velocities and physical properties of the streams are of secondary significance. When a chemical process takes place in a diffusion region, the controlling step is the rate at which the reaction components diffuse toward the reaction zone. The process is subsequently controlled by the velocities and physical properties of the streams. A method by which the effect of diffusional resistance may be eliminated from laboratory kinetic data should be employed in scaling up heterogeneous reactors. In certain instances, a process may be restricted to the desired region by controlling hydrodynamic conditions.
DIMENSIONAL ANALYSIS AND SCALE-UP EQUATIONS Dimensionless groups for a process model can be easily obtained by inspection from Table 13-2. Each of the three transport balances is shown (in vector/tensor notation) term-by-term under the description of the physical meanings of the respective terms. The table shows how various well-known dimensionless groups are derived and gives the physical interpretation of the various groups. Table 13-3 gives the symbols of the dimensions of the terms in Table 13-2. Tables 13-2 and 13-3 elucidate how the common dimensionless groups are derived. The boundary conditions governing the differential equations combined with the relative size of the system should be considered when determining dimensionless parameters. Using Table 13-2 to determine the dimensionless groups for any of the three equations, divide one set of the dimensions into all the others including the boundary conditions.
Scale-Up in Reactor Design
1041
Table 13-2 Development of the relations among dimensionless groups
Source: Himmelblau, D. M., and Bischoff, K. B., Process Analysis and Simulation, John Wiley & Sons, New York, 1965.
1042
Modeling of Chemical Kinetics and Reactor Design
Table 13-3 Notation for dimensionless quantities in Table 13-2 Variable
Equivalent characteristic quantity
c t Length
C θ L
Rt v p τ T
R ±t V P τ± T±
SR
S ±R
Source: Himmelblau, D. M. and Bischoff, K, Process Analysis and Simulation, John Wiley, New York, 1965.
In Table 13-2, the numerator of a well-known group is identified by the “arrowhead,” while the denominator is assigned by the “tail” of the arrow. For example, the Damköhler I represents the division of the dimensions representing the generation per unit volume by the dimensions representing the transport of mass by convection. This is defined as: R i± R± L = Damköhler I = i VC VC L
(13-3)
The Damköher II is determined by dividing the dimensions representing the generation per unit volume by the dimensions representing the transport of mass by molecular process as: R i± R ± L2 = Damköhler II = i DC DC L2
(13-4)
The Damköhler III is obtained by dividing the dimensions representing generation per unit volume of chemical reaction by the dimensions representing the transport of energy by convection. This is defined by
SR± SR± L = Damköhler III = T ± VρC p T ± VρC p L
(13-5)
Scale-Up in Reactor Design
1043
Other dimensionless parameters, namely the Reynolds number, Prandtl number, and Nusselt number can be represented as follows: ρV 2 L = ρVL = Reynolds number (N ) Re µV µ L2
VρC p L N Pe = N Re
k ρVL µ
=
C pµ k
= Prandtl number (NPr)
1 ( hT) hL L = Nusselt number (NNu) = kT k L2
(13-6)
(13-7)
(13-8)
It is also possible to interpret similarity in terms of dimensionless groups and variables in a process model. Kline [3] expressed that the numerical values of all the dimensionless groups should remain constant during scale-up. However, in practice this has been shown to be impossible [4]. Generally, it is rarely possible to satisfy all of the various similarity criteria in scale-up, especially those related to chemical and thermal dimensionless groups. An alternative solution is to determine the effect of each group and perform intermediate scale experiments to determine the effect of the critical groups. REACTOR SIZE AND SCALE-UP EQUATIONS In a preliminary consideration, the following scale-up relationships between the model and the prototype may be used in determining the reactor size. In attaining the same residence time in the model and the prototype, the dimensionless parameter (Damkhöler I) may be applied. This is expressed by
(Da I )m = (Da I )p
(13-9)
1044
Modeling of Chemical Kinetics and Reactor Design
R±L R±L or i = i VC m VC p
(13-10)
where the subscripts m and p represent the model and the prototype, respectively. Canceling out the physical constants, and noting that the concentration (initial or final) is the same for the model and the prototype yields
L = L V m V p
(13-11)
This shows that the residence time in the model and the prototype must be the same.
MATHEMATICAL MODELING One of the limitations of dimensional similitude is that it shows no direct quantitative information on the detailed mechanisms of the various rate processes. Employing the basic laws of physical and chemical rate processes to mathematically describe the operation of the system can avert this shortcoming. The resulting mathematical model consists of a set of differential equations that are too complex to solve by analytical methods. Instead, numerical methods using a computerized simulation model can readily be used to obtain a solution of the mathematical model. PROCEDURES IN SCALE-UP USING MATHEMATICAL MODELING There is no strict procedure for scale-up of a chemical reactor by mathematical modeling. Himmelblau [4] has reviewed the mathematical modeling approach, and others specific examples are expatiated by Rase [5] and Carberry [6]. The following describe the steps applied to a scale-up problem as they relate to a catalytic reactor having a fixed bed of solid catalysts. Development of Mathematical Expressions Various processes involved in fixed bed catalytic reactions are represented by mathematical descriptions derived from basic laws of
Scale-Up in Reactor Design
1045
physical and chemical rate processes. A process model for a single catalyst pellet is first derived because the pore structure and inner surfaces of the catalyst pellets strongly influence the reaction mechanism. Laboratory experimental data are obtained for many particle sizes in combination with pore-structure analysis. The optimum pore structure, size, and shape of the catalyst pellet are selected based on factors such as the cost and activity of the catalyst. The mathematical description of the process for a layer of catalyst pellet is then formulated. This depends on the process model for one catalyst pellet and incorporates corrections for non-uniformity of temperature and concentrations of the reaction mixture throughout the layer. Process Optimization In this step, theoretical optimum conditions for the entire catalyst bed involving a number of pertinent parameters, such as temperature, pressure, and composition, are determined using mathematical methods of optimization [7,8]. The optimum conditions are found by attainment of a maximum or minimum of some desired objective. The best quality to be formed may be conversion, product distribution, temperature, or temperature program. Preliminary Selection of Reaction Types In general, the optimum conditions cannot be precisely attained in real reactors. Therefore, the selection of the reactor type is made to approximate the optimum conditions as closely as possible. For this purpose, mathematical models of the process in several different types of reactors are derived. The optimum condition for selected parameters (e.g., temperature profile) is then compared with those obtained from the mathematical expressions for different reactors. Consequently, selection is based on the reactor type that most closely approaches the optimum. Consider the production of ethylene oxide by oxidation of ethylene with air or oxygen: C2H 4 +
1 catalyst → CH 2 — CH 2 + (CO 2 + H 2 O) O 2 AgO 2 u U 250 − 300 o C side reaction O 4 − 5 atms
(∆H R = −29.2 kcal)
1046
Modeling of Chemical Kinetics and Reactor Design
The optimum temperature programming is attained by increasing the temperature in accordance with the degree of conversion. This condition is imposed to minimize the complete combustion of ethylene that requires high activation energy. A fixed bed catalytic reactor type that can approximate this temperature program is the reactor with stagewise catalyst beds having internal heat exchangers between the stages. Process Stability and Parametric Sensitivity Stability of a chemical reactor for an exothermic process refers to the condition in which the rate of heat removal is equal to or greater than that of heat generated by the reaction, and for which both temperature and concentration do not significantly vary (Chapter 6). Stability is one of the principal factors in the selection of a reactor. Bilous and Amundson [9] have reviewed parametric sensitivity for the condition of a chemical reactor involving thermal behavior and its sensitivity to small variations in process parameters. For example, a slight variation in the feed concentration or the reactor inlet temperature results in a significant change in the temperature profile in the reactor. Parametric sensitivity of the reactor may be determined through the mathematical description of the product. Final Selection of Reactor System In this case, economic and technical considerations are incorporated with the results from the preceding steps to determine the final reactor system with respect to the size of the experimental reactor and its operating conditions. The data from the experimental reactor are used to make appropriate corrections for the mathematical model derived in the preceding steps. At this stage, it is essential to review the previous steps for revision of earlier results. DIMENSIONAL SIMILITUDE AND MATHEMATICAL MODELING A combination of dimensional similitude and the mathematical modeling technique can be useful when the reactor system and the processes make the mathematical description of the system impossible. This combined method enables some of the critical parameters for scale-up to be specified, and it may be possible to characterize the underlying rate of processes quantitatively.
Scale-Up in Reactor Design
1047
For example, Hamilton et al. [10] employed dimensional similitude in combination with mathematical modeling in the design of a pilot plant and in evaluating the results to provide the basis for scale-up to a commercial scale plant involving a reaction of the type k1
k2
k −1
k −2
A[B[C A differential equation describing the material balance around a section of the system was first derived, and the equation was made dimensionless by appropriate substitutions. Scale-up criteria were then established by evaluating the dimensionless groups. A mathematical model was further developed based on the kinetics of the reaction, describing the effect of the process variables on the conversion, yield, and catalyst activity. Kinetic parameters were determined by means of both analogue and digital computers. Rase [5] has presented several case studies of different scale-up methods involving industrially important reactions. Murthy [11] has provided a general guideline for the scale-up of slurry hydrogenation reactors, and other scale-up processes are illustrated elsewhere [12].
SCALE-UP OF A BATCH REACTOR In scaling-up a batch reactor plant to a full-scale commercial plant, every full-size reactor in the plant will have a working volume, which is some multiple of the capacity of a pilot plant reactor. The production of the full-scale plant is usually predicted from cycle times experienced in the small-scale plant (see Chapter 4). Generally, it is not difficult to maintain the same cycle time when charging the feeds to the reactor. However, problems can arise during temperature control, such as the times required to complete temperature adjustment steps in the larger unit. When comparing both model and full-scale plants with the same jacket configurations having the same operating conditions, the same steps take longer at the larger scale because heat transfer area does not scale-up at the same rate as the volume. Steve [13] introduced the concept of the “aspect ratio” of a reactor (defined as the tangent -to- tangent length of the reactor divided by the reactor diameter). It was shown that when the aspect ratio (R) is the same for model and prototype reactors, then the increase in the
1048
Modeling of Chemical Kinetics and Reactor Design
heat transfer area is only a fraction of the increase in the volumetric capacity. The following reviews the method developed by Steve, and determines the aspect ratio required to make the heat transfer area increase proportionally to the volume. THE MATHEMATICS OF SCALE-UP Consider the reactor in Figure 13-1 with defined geometric configurations, the working volume WV is expressed as: π WV = F aD3 + 7.48 D 2 L 4
Figure 13-1. Geometric parameters of a batch reactor.
(13-12)
Scale-Up in Reactor Design
1049
Conversion: 7.48 gal = 1 ft3 The aspect ratio R is:
R=
L D
(13-13)
The constant d is given by π d = 7.48 = 5.875 4
(13-14)
Substituting Equations 13-13 and 13-14 into Equation 13-12 yields WV = F[aD3 + dRD3]
(13-15)
13
WV D= F (a + dR )
(13-16)
where F is the fraction of the total volume occupied by the working volume. Assume that the total area of the bottom head is effective for heat transfer. Therefore, the total surface area of the reactor in Figure 13-1 available for heating or cooling the working volume is defined by A = tD2 + πDJ
(13-17)
where J = straight side length covered by the working volume (WV), ft t = factor for determining the surface area (ft2) of the bottom head = 0.93 for ASME standard F&D heads The working volume can be defined using Equation 13-12 or it can be defined as related to the straight side length that it occupies. Making this expression in J equal to Equation 13-12 with constants as expressed by Equation 13-14 gives WV = F[aD3 + dD2L] = aD3 + dD2J
(13-18)
1050
Modeling of Chemical Kinetics and Reactor Design
or J = ( F − 1)
aD + FL d
(13-19)
Substituting Equation 13-19 into Equation 13-17 gives aD A = tD 2 + ( F − 1) + FL πD d 4a( F − 1) D + FL πD = tD 2 + 7 . 48 π A = tD 2 +
4a ( F − 1) D 2 + πFLD 7.48
where L = RD
(13-20) (13-13)
Substituting Equation 13-13 into Equation 13-20 and rearranging yields 4a ( F − 1) 2 A = t + D + πFRD 2 7.48 where f = t +
(13-21)
4a ( F − 1) 7.48
and g = πF The heat transfer area A becomes: A = fD2 + gRD2
(13-22)
DEFINING THE SCALE-UP FACTORS The scale-up factors are defined as follows [13]: SUFV = volume scale-up factor
=
WV2 large scale reactor working volume = WV1 pilot plant reactor working volume
(13-23)
Scale-Up in Reactor Design
1051
SUFV = heat transfer area scale-up factor
=
A 2 large scale heat transfer area = A1 pilot plant heat transfer area
(13-24)
Substituting Equation 13-22 into Equation 13-24 gives SUFA =
D 22 (f + gR 2 ) D12 (f + gR1 )
(13-25)
W F where D = V (a + dR )
1
3
(13-16)
Assume that the scaled-up reactor has the same bottom head type (e.g., ASME standard F&D) as the pilot plant scale reactor. Equation 13-25 then becomes 2
3 WV 2 F (a + dR 2 ) f + gR 2 SUFA = WV1 f + gR1 F a + dR 1) ( 2 3
(13-26)
2 3
W a + dR1 f + gR 2 = V2 WV1 a + dR 2 f + gR1 SUFA in terms of SUFV becomes 2
a + dR1 3 f + gR 2 SUFA = SUFV • a + dR 2 f + gR1
(13-27)
Equation 13-27 is a general expression that describes how the heat transfer area increases when increasing the volume of a reactor from the pilot plant to the full-scale plant.
1052
Modeling of Chemical Kinetics and Reactor Design
MAINTAINING CONSTANT ASPECT RATIO: R Because there are advantages in maintaining geometric similarity between the pilot plant and the full-scale plant reactors, the larger unit often has the same aspect ratio as the small unit. That is, R2 = R1. Equation 13-27 then becomes 2
SUFA = SUFV 3
(13-28)
For example, if the larger reactor is twice the size of the pilot unit (i.e., SUFV = 2), and the two units share the same aspect ratio, then the heat transfer area only increases by 1.59 from Equation 13-28: 2
SUFA = 2 3 = 1.59 The SUFA would, therefore, be 79.5% of the SUFV. Table 13-4 gives the required aspect ratio for the larger unit for SUFA = SUFV at various R 1 values. Table 13-4 shows that SUF A becomes an increasingly smaller percentage of SUFV as the latter becomes larger at a constant aspect ratio R. LARGER ASPECT RATIO: SUFA = SUFV In determining the aspect ratio required when SUFA = SUFV (although it may not be a practical solution), substitute SUFV for SUFA on the left side of Equation 13-27: 2
a + dR1 3 f + gR 2 SUFV = SUFV • a + dR 2 f + gR1 2 3
1 SUFV3
a + dR1 = a + dR 2
2
(13-29)
3
f + gR 2 f + gR1 2
a + dR1 f + gR 2 or SUFV = a + dR 2 f + gR1
3
(13-30)
Scale-Up in Reactor Design
1053
Table 13-4 Required R2 values for SUFA = SUFV at various R1 values Required R2 value R1
SUFV
Rounded
Raw value
2 3 5 2 3 2 3 4 2 3 2
3 5 9 4 6.5 5 8 11 7 11 9
3.11 5.13 9.14 4.01 6.47 4.96 7.89 10.81 6.92 10.81 8.90
1
1.5 2
3 4
Source: Steve, E. H., Reactor Design Considerations, Chemical Engineering, pp. 96–98, December 1997.
The following constants are defined as: M = f + gR1
(13-31)
N = a + dR1
(13-32)
Equation 13-30 becomes: N 2 (f + gR 2 ) • M 3 (a + dR 2 )2 3
SUFV =
(13-33)
Rearranging Equation 13-33 yields M3 2 3 SUF • (a + dR 2 ) = (f + gR 2 ) V N2
where Ψ = SUFV •
M3 N2
Equation 13-34 becomes:
(13-34)
(13-35)
1054
Modeling of Chemical Kinetics and Reactor Design
Ψ(a 2 + 2adR 2 + d 2 R 22 ) = f 3 + 3f 2 gR 2 + 3fg 2 R 22 + g 3 R 32
(13-36)
Rearranging Equation 13-36 into a cubic equation becomes g 3 R 32 + 3fg 2 R 22 − Ψd 2 R 22 + 3f 2 gR 2 − 2adR 2 Ψ + f 3 − a 2 Ψ = 0 3fg 2 − Ψd 2 2 3f 2 g − 2adΨ f 3 − a2Ψ or R 32 + R R + + 2 2 g 3 = 0 (13-37) g3 g3
where the coefficients are: C1 =
3fg 2 − Ψd 2 g3
C2 =
3f 2 g − 2adΨ g3
C3 =
f 3 − a2Ψ g3
(13-38)
Substituting Equation 13-38 into Equation 13-37 gives R 32 + C1R 22 + C 2 R 2 + C 3 = 0
(13-39)
Equation 13-39 is a cubic equation in terms of the larger aspect ratio R 2. It can be solved by a numerical method, using the NewtonRaphson method (Appendix D) with a suitable guess value for R2. Alternatively, a trigonometric solution may be used. The algorithm for computing R2 with the trigonometric solution is as follows: Design choice inputs: R1 = 4, SUFV = 2, F = 0.8 Constants: a = 0.606, t = 0.931 Calculate: d, f, and g. Calculate: M, N, ψ. Compute the coefficients of the cubic equation, C1, C2, and C3. 1 6. Calculate: P = (3C 2 − C12 ) (13-40) 3
1. 2. 3. 4. 5.
Scale-Up in Reactor Design
7. Calculate: QV = 1 (2C13 − 9C1C 2 + 27C 3 ) 27 3
1055
(13-41)
2
P QV (13-42) 8. Calculate: DV = + 2 3 If DV < 0, the roots are real and unequal and a trigonometric solution is preferred. 9. Compute the angle Φ (ABV = the absolute value of the parameter P). QV 2 4 Φ = arccos ABV 3 27
0.5
(13-43)
10. Calculate the three roots: YY1, YY2, and YY3 ABV YY1 = + 2 3
Φ Cos 3
(13-44)
Φ + π Cos 3
(13-45)
Φ − π Cos 3
(13-46)
0.5
ABV YY2 = −2 3
0.5
ABV YY3 = −2 3
0.5
11. Compute the possible roots of R2. C (R 2 )i = YYi − 31 (13-47) 12. Select the positive value of R2 as the larger aspect ratio. An Excel spreadsheet (EXAMPLE 13-1.xls) was developed to determine R2 for given values of R1, SUFV, and other required parameters. A Rule-of-Thumb Steve [13] suggested a rule-of-thumb for calculating R2 required to make SUFA equal to SUFV. Using Table 13-4, it is possible to determine the full-scale pilot plant aspect ratio by
[
]
R 2 = ( R1 + 1)SUFV − 1
(13-48)
1056
Modeling of Chemical Kinetics and Reactor Design
Using Equation 13-48, the scale-up aspect ratio (R2) from R1 is determined as follows: Pilot plant aspect ratio R1
Scale-up aspect ratio R2
1 1.5 2 3 4
3 4 5 7 9
Example 13-1
Determine the aspect ratio of a full-scale batch reactor for SUFA = SUFV and at various values of R1 and SUFV as shown in Table 13-5. Solution An Excel spreadsheet (EXAMPLE 13-1.xls) was developed to determine R2 for given values of R1 SUFV, and other required parameters. The results of the simulation exercise are shown in Table 13-6. Table 13-5 R1
SUFV
1
2 3 4 5
1.5
2 3 4
2
2 3 4
3
2 3 4
4
2 3 4
Scale-Up in Reactor Design
1057
Table 13-6 Effect of scaling-up volume at constant aspect ratio SUFV
R2
SUFA
SUFA/SUFV × 100
1
2 3 4 5
3.11 5.13 7.14 9.14
1.58 2.08 2.52 2.92
79.4 69.3 63.0 58.5
1.5
2 3 4
4.01 6.47 8.92
1.59 2.08 2.52
79.4 69.3 63.0
2
2 3 4
4.97 7.89 10.81
1.59 2.08 2.52
79.4 69.3 63.0
3
2 3 4
6.92 10.81 14.70
1.59 2.08 2.52
79.4 69.3 63.0
4
2 3 4
8.89 13.77 18.65
1.59 2.08 2.52
79.4 69.3 63.0
R1
HEAT TRANSFER MODEL PREDICTING THE TEMPERATURE AND TIME FOR SCALE-UP In predicting the time required to cool or heat a process fluid in a full-scale batch reactor for unsteady state heat transfer, consider a batch reactor (Figure 13-2) with an external half-pipe coil jacket and non-isothermal cooling medium (see Chapter 7). From the derivation, the time θ to heat the batch system is: X Mc t1 − T1 θ= ln X − 1 Wh C h t1 − T2
where X = K1 = e
UA Wh C h
(13-49)
1058
Modeling of Chemical Kinetics and Reactor Design
Figure 13-2. A jacketed batch reactor.
Alternatively, for batch cooling with a non-isothermal cooling medium, the time required is: X Mc T1 − t1 θ= ln X − 1 Wc C c T2 − t1
where X = K 2 = e
(13-50)
UA Wc C c
TIME FOR SCALE-UP Following Steve’s method [13], for a reactor at any scale Xi = e
UA i Wi C
(13-51)
Scale-Up in Reactor Design
1059
where X i, A i, and W i are the specific values for the scale being considered. For example, when scaling-up from WV1 to WV2 UA1
X1 = e W1C
(13-52) UA 2
and X 2 = e W2 C
(13-53)
If the larger reactor has a larger size half-pipe jacket, the jacket flow increase is linear, hence W2 = kW1
(13-54)
Rearranging Equation 13-24 gives A2 = SUFA • A1
(13-55)
Substituting Equations 13-55 and 13-54 into Equation 13-53 gives
X2 = e
UA1SUFA kW1C
(13-56)
If both scale reactors have the same aspect ratio (L/D) then:
SUFA = SUFV2 3
(13-28)
X2 in terms of SUFV then becomes: 2
UA1SUFV3
X2 = e
kW1C
(13-57)
Applying the algebraic law of powers in Equation 13-57 gives X 2 = e a1b where a1 =
(13-58) UA1 W1C
(13-59)
2
SUFV 3 and b = k
(13-60)
1060
Modeling of Chemical Kinetics and Reactor Design
Jacket Outlet Temperature Using Equation 7-120 for batch cooling with an internal coil and a non-isothermal cooling medium,
I
II
III
IV
dq ′ dT = − Mc = Wc C c ( t 2 − t1 ) = UA∆t LMTD dθ dθ
(7-120)
UA
where X = e Wc C c The log mean temperature difference ∆tLMTD is determined by
∆t LMTD =
=
∆t 2 − ∆t1 ∆t ln 2 ∆t1
( T − t1 ) − ( T − t 2 ) T − t1 ln T − t2
(13-61)
Equating III and IV of Equation 7-120 gives
T − t1 ) − ( T − t 2 ) ( Wc C c ( t 2 − t1 ) = UA T − t1 ln T − t2
(13-62)
Scale-Up in Reactor Design
1061
UA t 2 − t1 or ( t 2 − t1 ) = Wc C c T − t1 ln T − t 2
(13-63)
T − t1 UA ln = T − t 2 Wc C c
(13-64)
Rearranging Equation 13-64 gives UA Wc C c
(T − t 2 )
(13-65)
or T – t1 = X(T – t2)
(13-66)
T − t1 = e
where X = e
UA Wc C c
The outlet fluid cooling temperature t2 can be expressed by I t2 =
II
T( X − 1) + t1 t − T = T+ 1 X X
(13-67)
The values of t1 and X in Equation 13-67 are constant. Temperature T varies from the temperature at the start of the cooling cycle T1 to the temperature at the end of the cooling cycle T2. When cooling T2 < T1, the I form of Equation 13-67 clearly shows that the predicted t2 at the beginning of the cycle will be larger than the predicted t2 at the end of the cycle. Alternatively, for batch heating with a non-isothermal heating medium, the log mean temperature difference ∆tLMTD is determined by ∆t LMTD =
[(t1 − T) − (t 2 − T)] t −T ln 1 t2 − T
(13-68)
1062
Modeling of Chemical Kinetics and Reactor Design
Substituting X2 into Equations 13-67, 13-49, and 13-50, it is possible to determine the effect of scale-up on the jacket outlet temperature and the time required in completing the temperature adjustment step. In directly predicting the expected value for the outlet temperature t2 from the jacket of a reactor scaled-up by some volume scale-up factor SUFV, substitute Equation 13-58 into form II of Equation 13-67. This gives
t −T t2 = T + 1 a b e1
(13-69)
For the full-scale reactor: M2 = M1 • SUFV
(13-70)
and WC2 = kWC1
(13-71)
Subscript 2 indicates the full-scale reactor, which yields
SUFV M1 c M2c = WC 2 C C kWC1C C
(13-72)
In directly predicting the expected value for the time required to complete a cooling step in a reactor scaled-up by some volume scaleup factor SUFv, substituting Equations 13-58 and 13-72 into Equation 13-50 yields M 2 c X 2 T1 − t1 θ= ln WC 2 C C X 2 − 1 T2 − t1 SUFV • M1 • c e a1b T1 − t1 or θ = ln kWC1C C e a1b − 1 T2 − t1
(13-73)
Alternatively, for a heating condition, the heating time required for scale-up is: SUFV • M1 • c e a1b t1 − T1 θ= ln kWh1C h e a1b − 1 t1 − T2
(13-74)
Scale-Up in Reactor Design
1063
Example 13-2
Consider an agitated batch reactor having the following parameters: A, ft2 C, Btu/lb °F CC, Btu/lb °F M, lb t1, °F T1, °F T2 ,°F U, Btu/hr-ft2 °F WC, lb/hr
265 0.52 1.0 29,962 104 221 158 74.0 28,798
Determine the time required to cool twice the volume of the pilot plant batch reactor. Solution The time required to cool the pilot plant batch reactor is 0.85 hr. Applying form II of Equation 13-67 and WCCC (t2 – t1) for the heat removal in the pilot plant reactor yields
t2 = T +
( t1 − T )
(13-67)
X
UA
X = e WC C C 74 × 265 = exp 28, 798 × 1.0 = 1.976
Heat removal, Q = WCCC (t2 – t1) This results in the following:
Start of cycle End of cycle ƒ
t2 °F
Heat removal, Q Btu/hr
Tonsƒ
161.79 130.67
1.66 × 106 0.77 × 106
138.3 164.2
1 ton of refrigeration = 3,517 W = 12,000 Btu/hr
1064
Modeling of Chemical Kinetics and Reactor Design
The results quantitatively show the significance of considering both boundaries of the unsteady state operation. The load required at the end of the cycle is less than one-half the load required at the start of the cycle. Steve [13] inferred that reporting the value at only one boundary may be misleading. For example, the total heat load (provided by chillers and heaters) from multiple reactors with overlapping temperature adjustment cycles may be skewed if the changes within those cycles are not considered. For the full-scale plant, assume: A constant overall heat transfer coefficient, U2 = U1
SUFV =
WV 2 =2 WV1
The size of the half-pipe jacket is identical at both scales, that is, k = 1.0 Therefore, WC 2 = kWC1 = 1.0 × WC1
a1 =
U1A1 74 × 265 = = 0.681 WC1C C 28, 798 × 1.0 2
2
SUFV 3 2 3 b= = = 1.587 k 1
where X 2 = e a1b = exp(0.681 × 1.587) = 2.95 Applying form II of Equation 13-67 and WCCC (t2 – t1) for the heat removal in the full-scale plant reactor yields
Scale-Up in Reactor Design
Start of cycle End of cycle
1065
t2 °F
Heat removal, Q Btu/hr
Tonsƒ
181.31 139.68
2.23 × 106 1.03 × 106
185.8 185.8
There are increased heat loads in the full-scale batch reactor because the heat transfer area is 1.59 times larger; the cooling rate WC remains constant. The time required to cool the batch reactor in a full-scale batch reactor is determined by Equation 13-73 SUFV • M1 • c e a1b T1 − t1 θ= ln kWC1C C e a1b − 1 T2 − t1
(13-73)
2 × 29, 962 × 0.52 2.95 221 − 104 θ= ln 28, 798 × 1.0 2.95 − 1 158 − 104 = 1.27 hr
The cooling time in a full-scale batch reactor is 1.27 hr, which is approximately 49% more than the 0.85 hr predicted at the smaller scale. Multiple temperature adjustment steps occur in a chemical reactor production cycle. The sum of these cycle time increases may be significant, and the plant capacity at the larger scale may be adversely affected if the cycle times are not corrected [13]. An Excel spreadsheet (EXAMPLE 13-2.xls) was developed for Example 13-2.
JACKET ZONING OF A BATCH REACTOR The heat transfer performance of a batch reactor system equipped with a partial pipe jacket can be improved using multiple zoning. This involves dividing the jacket into two or more zones. In this instance, each independent zone receives the heat transfer medium at the cooling or heating supply temperature at the inlets. The outlets from these zones are combined, and the flows of the medium blend to create a stream of some mixture temperature before the combined flow returns to the cooling or heating utility equipment. The zoning of the reactor
1066
Modeling of Chemical Kinetics and Reactor Design
enhances the heat transfer without attaining an increase in the jacket pressure drop [14]. Consider a single-zone jacket where there is an increase in the jacket flow, and a corresponding increase in the outside film coeffi∗ cient because h j = f ( N −Re0.2 , G ) . Therefore, a two-fold increase in the jacket flow results in an increase in hj2 by 2 0.8 h ∗ji . The overall heat transfer coefficient U = 1/[FFOL + 1/hj], and a larger outside coefficient subsequently increases the overall heat transfer coefficient. The overall heat flux will increase due to the combined effects of the increased flow and lower jacket outlet temperature. The net result is an increase in the pressure drop. To reduce the pressure drop, a batch reactor with a half-pipe jacket of length L and flowrate W can be partitioned into a two-zone jacket, each with a length L/2 and each supplied with W jacket flowrate. This doubles the jacket flow at a lower pressure drop in each zone. The flow in each zone can then be increased to increase the outside and overall heat transfer coefficients, which is similar to those of the single-zone jacket. MATHEMATICAL MODELING OF THE BATCH REACTOR Consider a batch reactor with a partial jacket that is divided into three zones (Figure 13-3). The flow to each zone is the same as the single-zone flow. The fluid velocity is maintained constant to maintain the same outside heat transfer coefficient as a single zone jacket. The heat balance to the three-zone jacket can be expressed by WJCC(tm – t1) = WzCC(tz1 – t1) + WzCC(tz2 – t1) + WzCC(tz3 – t1)
∗
(
(13-75)
)
−0.2 −2 3 h j = 0.023 N Re N Pr CP G • k or h j = f N R−0.2 , G . G = vρ, N Re = ρvD/µ.
Therefore
0.2 N Re h1 G N Re1 = 0.21 • 2 h2 N Re2 G1 N Re2
v10.2 v 2 v 2 • = v 20.2 v1 v1
0.8
. If v2 = 2v1,
0.2
v = 1 v2
h2 = 2 0.8 . h1
0.2
. But
0.2 h1 G1 N Re1 . = 0.2 h2 G2 N Re 2
N Re1 G2 v 2 . Therefore = G1 v1 N Re2
0.2
•
G2 = G1
Scale-Up in Reactor Design
1067
Figure 13-3. A zoned jacketed batch reactor.
Rewriting Equation 13-67 in a generalized form that shows the outlet temperature from any zone gives
t zi = T + where a i =
t1 − T e ai
(13-76)
UA i Wz C C
and subscript i is for the individual zone. Substituting Equation 13-76 into Equation 13-75, where W j = 3Wz, gives t − T 1 1 1 t m = T + 1 + + 3 e a1 e a 2 e a 3
(13-77)
Equation 13-77 is modified to give a more generalized equation for tm for any number of zones as:
1068
Modeling of Chemical Kinetics and Reactor Design
t − T 1 1 1 tm = T + 1 a1 + a 2 + . . . + az e e nz e
(13-78)
For nz = 1 and tm = t2, Equation 13-78 becomes Equation 13-67. Assume that the jackets have equal areas, therefore, for any multiple number of jacket zones, Ai =
AT nz
(13-79)
Substituting Equation 13-79 into Equation 13-78 and expanding a1, a2, . . . az, gives
t1 − T 1 1 1 tm = T + UA T + UA T + . . . + UA T n z n z Wz C C e n z Wz C C e n z Wz C C e
(13-80)
Since a1 = a2 = . . . = az, Equation 13-80 is expressed by t1 − T n z tm = T + UA T n z n z Wz C C e =T+
where υ =
t1 − T UA T e Wz C C
υ
(13-81)
1 nz
Because U and AT are constants over the cooling cycle, Equation 13-81 can be used to predict the temperature of the mixed outlet streams as:
Scale-Up in Reactor Design
t −T t m = T + 1 υ X
1069
(13-82)
TEMPERATURE ADJUSTMENT TIME Consider the jacket zoning of a batch reactor to determine the times required for a temperature adjustment step [14]. WC is replaced by nZWZ and the jacket outlet temperature t2 by tm in Equation 13-50. The heat balance for cooling is expressed by: I
II
III
IV
dq ′ dT = − Mc = n z Wz C C ( t m − t1 ) = UA∆t LMTD dθ dθ
(13-83)
For heating, the unsteady state heat balance is given by
V
VI
VII
dq ′ dT = Mc = n z Wz C h ( t1 − t m ) = UA∆t LMTD dθ dθ
(13-84)
The log mean temperature difference ∆tLMTD for cooling is: ∆t LMTD =
( T − t1 ) − ( T − t m ) T − t1 ln T − tm
(13-85)
For heating, ∆tLMTD is expressed by: ∆t LMTD =
( t1 − T ) − ( t m − T ) t −T ln 1 tm − T
(13-86)
Combining forms II and III of Equation 13-83 for cooling and substituting tm in Equation 13-82 gives
1070
Modeling of Chemical Kinetics and Reactor Design
− Mc
dT = n z Wz C C ( t m − t1 ) dθ t −T = n z WC C C T + 1 υ − t1 X X υ − 1 = n z Wz C C (T − t1 ) Xυ
(13-87)
Rearranging Equation 13-87 and integrating between the boundary conditions, θ = 0 → θ, T = T1 → T2, gives T2
−∫
T1
θ
n W C X υ − 1 dT = z z C dθ T − t1 Mc X υ ∫0
T −t n W C X υ − 1 ln 1 1 = z z C θ υ T2 − t1 Mc X
(13-88)
The cooling time θ is given by Mc X υ T1 − t1 θ= ln n z Wz C C X υ − 1 T2 − t1
(13-89)
Alternatively, the time required for heating the batch system is: Mc X υ t1 − T1 θ= ln n z Wz C h X υ − 1 t1 − T2
(13-90)
THE OUTLET TEMPERATURE OF A SCALED-UP BATCH SYSTEM Consider the scale-up of a batch reactor from a pilot plant reactor to a full-scale reactor. Rewriting Equation 13-82 to the full-scale reactor yields:
Scale-Up in Reactor Design
tm = T +
where P =
t1 − T X 2P
1071
(13-91)
1 n z2
The subscript 1 refers to the process parameters for the reactor at the smaller scale, and the subscript 2 refers to those parameters for the reactor at the larger scale. Because the pilot plant and full-scale reactors have the same aspect ratio (L/D), this gives 2
A T 2 = SUFA • A T1 = SUFV 3 • A T1
(13-28)
Also, W2 = knz2 Wz1
(13-92)
Combining Equations 13-28 and 13-92, and the definitions of X1 and X2, gives
X2 = e
UA T 2 W2 C C
or X 2 =
=e
2 U SUFv 3 A T1 kn z 2 Wz1C C
2 3 SUFV kn z 2 X1
(13-93)
(13-94)
Substituting Equation 13-94 into Equation 13-91 gives a general expression for predicting the temperature resulting from mixing the outlet streams from multiple jacket zones. This is expressed by t − T t m2 = T + 1 s X1 2
SUFV 3 where s = kn z 2
(13-95)
1072
Modeling of Chemical Kinetics and Reactor Design
The time required to complete a cooling temperature adjustment step for the full-scale reactor is: M 2 c X 2 T1 − t1 θ= ln WC 2 C C X 2 − 1 T2 − t1
(13-96)
where M2 = SUFV • M1
(13-67)
Substituting Equations 13-70 and 13-92 into Equation 13-96 gives for cooling: SUFv M1c X 2 T1 − t1 θ= ln kn z 2 Wz1C C X 2 − 1 T2 − t1
(13-97)
Alternatively, the time required for heating a full-scale batch reactor is: SUFv M1c X 2 t1 − T1 θ= ln kn z 2 Wz1C h X 2 − 1 t1 − T2
(13-98)
Example 13-3
The jacket of a pilot plant batch reactor is divided into three zones. Using the data in Example 13-2, determine the outlet temperature, the heat removed, and the cooling time for both pilot and full-scale batch reactors. Solution An Excel spreadsheet program (EXAMPLE13-3.xls) was developed to determine the mixed outlet temperature at the start and end of the cooling cycles, the heat removal, and the cooling time for the pilot and full-scale batch reactors. Table 13-7 gives the results for the number of zones. The results show that segmenting the jacket with accompanying higher jacket flows reduces the batch cooling time.
1 2 3 4 1 2 3 4
Number of jacket Case zones 28,798 57,596 86,394 115,192
Total jacket flowrate, lb/hr 28,798 28,798 28,798 28,798
Flow in each zone, lb/hr 1.587 0.794 0.529 0.397
s
X ls 2.947 1.717 1.434 1.31
Factors
181.3 152.86 139.41 131.69
Start °F
139.68 126.55 120.34 116.78
End °F
Tm2 (or tz2) at
Table 13-7 Effect of jacket zoning in a scale-up batch reactor
185.5 234.5 254.9 265.8
Start
85.6 108.2 117.6 122.8
End
Cooling load, tons
1.27 1.0 0.92 0.88
Cooling step time, hr
Scale-Up in Reactor Design 1073
1074
Modeling of Chemical Kinetics and Reactor Design
ASPECT RATIO (R) IN JACKET ZONING AND SCALE-UP OF A BATCH REACTOR A combination of jacket zoning and aspect ratio adjustment is used to provide a scale-up reactor that performs temperature adjustment steps in the same time as the pilot scale unit [14]. From Equation 13-27 2
a + dR1 3 f + gR 2 SUFA = SUFV • a + dR 2 f + gR1
a + dR1 Using β = a + dR 2
2
3
f + gR 2 f + gR1
(13-27)
(13-99)
Equation 13-27 becomes 2
SUFA = SUFV 3 • β
(13-100)
If the pilot plant and the full-scale reactors have the same aspect ratio, then β = 1 and 2
SUFA = SUFV 3
(13-28)
In specifying the number of jacket zones and the aspect ratio for a full-scale reactor, there is a limitation on the temperature adjustment time. This implies that it must be of the same duration as experienced in the pilot plant reactor. Combining Equations 13-89 and 13-97 yields SUFV X 2 Xυ = υ kn z2 X 2 − 1 X − 1
(13-101)
Rearranging the variables to establish a series of constants gives
H=
SUFV kn z 2
(13-102)
Scale-Up in Reactor Design
r=
Xυ Xυ − 1
K=
r H
1075
(13-103)
(13-104)
Substituting H, r, and K into Equation 13-101 gives X2 r = H X 2 − 1 K=
(13-105)
X2 X2 − 1
or X 2 =
K K −1
(13-106)
From Equation 13-53 UA 2
X 2 = e W2 C and W2 = nz2kW1
(13-53) (13-107)
A2 = SUFA • A1 2
= SUFV 3 • A1 • β
(13-108)
Substituting Equations 13-107 and 13-108 into Equation 13-53 gives
X2 = e
2 3 U A1SUFV β W1C C kn z 2
Equating Equations 13-106 and 13-109 gives
(13-109)
1076
e
Modeling of Chemical Kinetics and Reactor Design
2 3 UA1SUFV β W1C C kn z 2
=
K K −1
(13-110)
2
or
β=
UA1 SUFV 3 β K = ln W1 C C kn z 2 K − 1
W1 C C kn z 2
UA1 (SUFV )
2
3
K ln K − 1
(13-111)
From Equation 13-99 M = f + gR1
(13-31)
N = a + dR1
(13-32)
Equation 13-99 becomes N β= a + dR 2
2
3
f + gR 2 M
f + gR 2
where Q =
(a + d R 2 )
2
(13-112)
(13-113) 3
Equation 3-112 becomes 2
β=
N 3 •Q M
or Q = β
(13-114)
M N
2
3
(13-115)
Rearranging Equation 13-113 gives Q(a + dR2)2/3 = f +gR2
(13-116)
Scale-Up in Reactor Design
1077
Expanding and rearranging Equation 13-116 yields Q3(a +dR2)2 = (f +gR2)3 3fg 2 − Q 3d 2 2 3f 2 g − 2adQ 3 f 3 − a 2Q3 R 32 + + R + R = 0 (13-117) 2 2 g3 g3 g3
Equation 13-117 is a cubic equation in R2 where
C1 =
3fg 2 − Q 3d 2 g3
C2 =
3f 2 g − 2adQ 3 g3
C3 =
f 3 − a 2Q3 g3
(13-118)
Equation 13-117 becomes R 32 + C1R 22 + C 2 R 2 + C 3 = 0
(13-119)
Using the Microsoft Excel spreadsheet EXAMPLE13-4.xls, the aspect ratio (i.e., the root R2) of Equation 13-119 of the zoned fullscale reactor can be determined. R2 was reviewed earlier for a singlezone batch reactor.
Example 13-4
Using the data in Example 13-2, determine the aspect ratio for the same cooling time (0.85 hr) as the larger unit, with the working volume twice that of the pilot plant scale of a segmented batch reactor. Solution Table 13-8 shows the results of the simulation exercise for R2 (L/D2) at varying number of zones. When nz2 = 1, the value of R2 is quite high, which relates to a taller reactor with smaller size. Correspondingly,
r
2.025 2.025 2.025 2.025
nz2
1 2 3 4 2 1 0.667 0.5
H 1.013 2.025 3.036 4.05
K 0.013 1.025 2.036 3.05
K – 1 77.92 1.976 1.491 1.328
X2 6.397 2 1.76 1.667
SUFA –129.67 –2.96 –1.69 –1.28
C1
–26.6 –0.47 –0.21 –0.12
C2
–1.35 0.00 0.01 0.02
C3
Table 13-8 Aspect ratio R2 (L/D)2 for zoning scale-up of a batch reactor using Equation 13-119 129.87 3.11 1.8 1.36
(L/D)2
1078 Modeling of Chemical Kinetics and Reactor Design
Scale-Up in Reactor Design
1079
the value of X2 in this case is also high. The results show that R2 decreases as the number of zones nz2 increases. However, an increase in the aspect ratio from 1 to 3 would require an additional blade on the agitator, which could present problems in achieving the same mixing pattern as the pilot scale reactor.
NOMENCLATURE a Factor for determining the capacity (gal) for the bottom head = 0.606 for ASME Standard flanged and dished heads A Total heat transfer surface area, ft2 AB Heat transfer area on the bottom head of the reactor, ft2 Ai Heat transfer area of a zone = AT/nz, ft2 AS Heat transfer area on the straight side of the reactor, ft2 AT Total heat transfer surface area = AS + AB, ft2 c Heat capacity of mass of material in the batch reactor, Btu/ lb • °F Cc Heat capacity of coolant jacket fluid, Btu/lb • °F Ch Heat capacity of heating jacket fluid, Btu/lb • °F C1,C2,C3 Coefficients of the cubic equation D Reactor inside diameter, ft. F Fraction of the total volume occupied by the working volume. G Mass flowrate, lb/hr • ft2 hj,hj1,hj2 Outside film heat transfer coefficients, Btu/hr • ft2 • °F J Straight side length covered by the working volume, WV, ft k Scale-up term for jacket flow, dimensionless L Reactor straight side (tangent-to-tangent) length, ft L ′ Flow length of a half-pipe jacket, ft LMTD Log mean temperature difference, °F M Mass of material in the batch reactor, lb nz Number of zones, dimensionless P 1/nz2, dimensionless R Aspect ratio, L/D dimensionless SUFA Heat transfer area scale-up factor = A2/A1 SUFV Volume scale-up factor = WV2/WV1 t Factor for determining the surface area, ft2 of the bottom head = 0.931 for ASME standard F&D heads t1 Jacket inlet temperature, °F t2 Jacket outlet temperature, °F tm Mixed outlet temperature, °F
1080
Modeling of Chemical Kinetics and Reactor Design
tzi T T1 T2 U W WC WJ Wh WZ WV X z YYi θ
Outlet temperature from zone i, °F Temperature of mass of material in the batch reactor, °F Initial batch temperature, °F Final batch temperature, °F Overall heat transfer coefficient, Btu/hr • ft2 • °F Jacket flowrate, lb/hr Coolant jacket flowrate, lb/hr nz • WZ, lb/hr Heating jacket flowrate, lb/hr Flow rate to a zone, lb/hr Working volume, gal eUA/WC = eai A generalized subscript used for counting total zone numbers Roots of the cubic equation Time required to complete the cooling or heating cycle, hr
REFERENCES 1. Kabel, R. L., Reaction Kinetics, Bisio, A. and Kabel, R. L., “Scaleup of chemical processes conversion from laboratory scale tests to successful commercial size design,” John Wiley & Sons, 1985. 2. Kafarov, V., Cybernetics Methods in Chemistry & Chemical Engineering, MIR Publishers, Moscow, 1976. 3. Kline, S. J., Similitude and Approximation Theory, McGraw-Hill, New York, 1965. 4. Himmelblau, D. M., Mathematical Modeling, Bisio, A., and Kabel, R. L., “Scaleup of chemical processes,” John Wiley & Sons, 1985. 5. Rase, H. F., “Chemical reactor design for process plants, vol II: Case studies and design data,” John Wiley & Sons, New York, 1977. 6. Carberry, J. J., Chemical and Catalytic Reaction Engineering, McGraw-Hill, New York, 1976. 7. Edgar, T. F. and Himmelblau, D. M., Optimization of Chemical Processes, McGraw-Hill, 1988. 8. Beveridge, G. S. G. and Schechter, R. S., Optimization: Theory and Practice, McGraw-Hill, 1970. 9. Bilous, O. and Amundson, N. R., Am. Inst. Chem. Eng., J., 2, 117, 1965. 10. Hamilton, L. and Harrington, Chem., Eng., Prog., 58 (2), pp. 55–59, 1962.
Scale-Up in Reactor Design
1081
11. Murthy, A. K. S., “Design and scaleup of slurry-hydrogenation systems,” Chemical Engineering, pp. 94–107, September 1999. 12. Perry, R. H. and Green, D. W. (Eds.) Perry’s Chemical Engineers Handbook, 6th ed., McGraw-Hill, New York, 1984. 13. Steve, E. H., “Reactor design considerations (Parts 1 and 2),” Chemical Engineering, pp. 96–102, 1997. 14. Steve, E. H., “Jacket zoning in reactor scale-up (Parts 3 and 4),” Chemical Engineering, pp. 92–98, January 1998. 15. Steve, E. H., private communications, 2000.
1082
Modeling of Chemical Kinetics and Reactor Design
CHAPTER THIRTEEN
Nomenclature
A A, B a, b, . . . c, d Av B C* C, D C′AO CA CAO Cd CE CES CET CL CM Cp Cp Cp Cs Cv Cv Cx d
cross sectional area; heat transfer area of heating or cooling coil, m2 reactants substances A, B, . . . C, D . . . cross-sectional area of tank, m2 number of blades on impeller oxygen concentration in equilibrium with the partial pressure of oxygen, kg/m3 products of reaction initial concentration, mol/unit mass concentration of key reactant species with stoichiometric coefficient, mol/m3 initial concentration, mol/m3 nonviable cell concentration, kg/m3 enzyme concentration, kg/m3 concentration of the complex, ES*, kg/m3 total enzyme concentration, kg/m3 concentration of dissolved oxygen, kg/m3 Monod constant, mol/m3 heat capacity, kJ/kg•K specific molar heat capacity or heat capacity at constant pressure, J/mol•K product concentration, kg/m3 substrate concentration, kg/m3 specific molar heat capacity or heat capacity at constant volume, J/mol•K viable cell concentration, kg/m3 cell concentration, kg/m3 diameter, mm 1082
Nomenclature
D DA DA Dmax Dl Dp Dr dt DT E E EA F FAO FFj fi G G gc GHSV h H h H hj ∆Hv ∆HR J k K k kd k, ki, kii, kiii, kiv KI kl kLa
1083
dilution rate, h–1 diffusion coefficient of species A in a bulk fluid, m 2/s impeller diameter, m maximum rate of cell production, h–1 axial diffusivity, m 2/s effective particle diameter, mm radial diffusivity, m 2/s tube diameter, mm tank diameter, m exit age residence time distribution function (min–1) height of the agitator from the bottom of tank activation energy, J/mol cumulative residence time distribution function feed molar rate, mol/s fouling factor, inside vessel fugacity of pure i Gibbs free energy, J/mol A mass flow rate, kg/s; superficial mass velocity, lb/hr•ft2, kg/m2•s dimensional constant, 1 kg•m/s2•N gas hourly space velocity, h–1 enthalpy per unit mass, kJ/kg enthalpy, J/mol heat transfer coefficient, W/m2•K liquid height, m film coefficient on inside surface of jacket, W/m2•K heat of vaporization, J/mol heat of reaction, J/mol baffle width reaction rate constant, (mol/m3)1–n s–1 equilibrium constant for the stoichiometry thermal conductivity, W/m•K death rate coefficient, s–1 reaction rate constants based on r, r i, r ii, r iii, r iv dissociation constant for inhibitor binding, kg/m3 axial thermal conductivity, W/m•K mass transfer coefficient, min–1
1084
Km ko kp kr Ks L LHSV M MA Mj ML – m i n N NA nA No NQ NT OTP OTR OUR ∆P P pA Q Qg Qp Qr R
R R –rA –r ′A
Modeling of Chemical Kinetics and Reactor Design
Michaelis-Menten constant, kmol/m3 pre-exponential factor of single reaction specific rate constant with product, s–1 radial thermal conductivity, W/m•K The Monod constant, kg/m3 length of tubular reactor; unit depth of packed bed; agitator blade length liquid hourly space velocity, h–1 mass, kg molecular weight of A, kg/mol of A molecular weight, kg/mol molar mass of species, kg/kmol; mass of solid or catalyst, kg mass fraction of component i overall order of reaction number of equal-sized CFSTR; impeller rotational speed, s–1 moles of compound A number of molecules A initial mole pumping number total mole optimum temperature progression, oC oxygen transfer rate oxygen uptake rate pressure drop, Pa total pressure, Pa partial pressure of compound A, Pa heat duty, J heat generation, W effective pumping capacity heat removal, W ideal gas law constant 8.314 J/mol•K 1.987 cal/mol•K 0.08206 lit•atm/mol•K recycle ratio number of baffles rate of reaction of species A, mol/m3•s molar rate of conversion per unit mass of the solid, kmol/kg•s
Nomenclature
r, ri, rii, riii, riv rp rs rsx rx ∑rcon ∑rgen S SA ST SV T t tb Tc Th tholding time Topt ∆TLMTD tr tt t– tplug flow u –u U V v vL Vmax Vo Vp VR W W WS XA xi xw
1085
rate of reaction, an intensive measure production rate of some product, kg/m3•h consumption rate of substrate, kg/m3•h rate of substrate concentration, kg/m3•h growth rate of cells, kg/m3•h sum of all the rates of consumption, kg/m3•h sum of all the rates of generation, kg/m3•h cross-sectional area of reactor, m2 linear function of the characteristic velocity space time, s space velocity, s–1 temperature, oC time, s total batch cycle time, h coolant temperature, oC heating coil temperature, oC holding time, s optimum temperature, oC log mean temperature difference, oC reaction time, s turnaround time, s reactor holding time or mean residence time of a fluid in a flow system = V/u, s plug flow mean residence time, s volumetric flowrate, m3/s internal energy per unit mass of mixture, kJ/kg overall heat transfer coefficient, W/m2•K reactor volume, m3 characteristic velocity, m/s velocity, m/s maximum rate of reaction (MM kinetic parameter) kmol/m3•s initial volume, m3 volume of catalyst solid, m3 reactor volume; final volume, m3 mass of solids in the reactor; mass of catalyst, kg agitator blade width shaft work, J fraction of A converted, the conversion mole fraction of i in the mixture wall thickness of vessel, mm
1086
Modeling of Chemical Kinetics and Reactor Design
Z ZAA y
gas compressibility factor Boltzmann constant = 1.30 × 10–16 erg/K general extensive property concentration (kg y)/m3 yield coefficient, (kg x)/(kg s)
Yx s
DIMENSIONLESS GROUPS D vL
vessel dispersion number
D vd
intensity of axial dispersion
Re =
dvρ ρND 2 inertia forces , µ µ viscous forces
Reynolds number
Pr =
C p µ hydrodynamic boundary layer thermal boundary layer k
Prandtl number
total heat transfer hD k heat transfer by conduction
Nusselt number
Sc =
µ hydrodynamic boundary layer ρD mass transfer boundary layer
Schmidt number
Bo =
total momentum transfer ud = ( Re)(Sc) molecular heat transfer D
Bodenstein number
Pe =
vL mass transfer by convection D mass transfer by diffusion
Peclet number
Po =
Pg c total dissipated power ρN 3 D 5A power due to inertia
Power number
Fr =
N 2 D A v 2 inertia forces , g gL gravitational forces
Froude number
Nu =
Da I =
chemical reaction rate rL vC mass transport by convection
Damköhler I number
Da II =
rL2 chemical reaction rate DC mass transport by diffusion
Damköhler II number
Nomenclature
1087
GREEK LETTERS α, β ρ δ δ(t – to) εA θ µi µ µ µmax π σ2 τ υ φ λ ∆ σ θ2 γi φ Σ ei(α)
orders of reaction fluid density, kg/m3 Dirac delta function, an ideal pulse; change Dirac delta function occurring at time to (s-1) expansion factor, fractional volume change on complete conversion of A dimensionless time units [ t / t ] (–) chemical potential of species i fluid viscosity, (kg/m•s), Pa•s specific growth rate, s–1 maximum specific growth rate, s–1 total pressure (Pa) variance of a tracer curve or distribution functions (s2) space time CAOV/uCAO (s) stoichiometric coefficient ratio overall fractional yield Life expectancy, s difference 2 dimensionless variance σ 2 / t (–) fugacity coefficient (= fi/p) Factor summation exponential integral (page 767)
[
]
GLOSSARY OF ABBREVIATIONS ASME CFSTR CFD CFM DIERS exp IR HAZAN HAZOP MM MMM
American Society of Mechanical Engineers Continuous flow stirred tank reactor Computational fluid dynamics Computational fluid mixing Design Institute for Emergency Relief Systems exponential Infrared (spectroscopy) Hazard analysis Hazard and operability studies Michaelis-Menten Maximum-mixedness model
1088
NMR OTP OTR OUR PFR RTD TIS
Modeling of Chemical Kinetics and Reactor Design
Nuclear magnetic resonance Optimum temperature progression Oxygen transfer rate Oxygen uptake rate Plug flow reactor Residence time distribution Tank in series
1096
Modeling of Chemical Kinetics and Reactor Design
CHAPTER THIRTEEN
About the Author A. Kayode Coker, Ph.D., a senior lecturer and Course Director at Jubail Industrial College, and consultant for AKC Technology in England, is a chartered chemical engineer, corporate member of the Institution of Chemical Engineers in the U.K., and member of the American Institute of Chemical Engineers. He holds a B.Sc. honors degree in Chemical Engineering, an M.Sc. in Process Analysis and Development, and Ph.D. in Chemical Engineering, all from Aston University, Birmingham, U.K. Dr. Coker has authored Fortran Programs for Chemical Process Design, Analysis and Simulation, and written a topic section in the Encyclopedia of Chemical Processing and Design (Vol. 61). He has directed and conducted short courses for Procter & Gamble in the U.K., Saudi Basic Industries Corporation (SABIC) and Saudi Aramco Shell Refinery Company (SASREF) in Saudi Arabia. His articles have been published in several international journals.
1096
3321 - index
5/23/01
1:50 PM
Page 1089
Index A
B
Absorbance, 154–158 Absorption spectrometry, 166 Accelarating rate calorimeter, 926–932 Acetaldehyde, 35–36 Acetic anhydride, 403–405, 452, 454–457 Acetylated castor oil decomposition, 465–472 Acetylation of benzyl chloride, 202–204 Acid-base catalysis, 26–27 Activated complex, 2, 3 Activation energy, 2, 12–15, 111–112, 197–198 Active centers, 11 Active site, 29 Adiabatic reaction in a CFSTR, 447, 509 in a non-isothermal batch reactor, 463–467 Adiabatic temperature, 924, 928 Adsorption, 30 Age distribution functions, 664, 668, 677 Agitation, 554, 556–562 Algebraic stress model, 795 Alkylation reaction, 239, 910 Ammmonia oxidation, 7 Ammmonia synthesis, 1, 6, 81–85, 115, 213–216, 230, 429, 478–479, 481–483, 543, 815, 918, 1039 Antoine relationship, 953, 965 Arrhenius equation, 12–14, 37, 111, 180, 502, 838 ASME code, rupture disc terminology, 980 Aspect ratio, 857, 1052–1055, 1057, 1074, 1078 Atomic absorption, 167 Atomic absorption spectrophotometer, 680 Autocatalytic reactions, 26, 28, 138–140 Automated pressure tracking adiabatic calorimeter, 932–934 Autothermal reactors, 477–480 Axial flow, 558, 562
Bacteria, 854 Basics of non-ideal flow, 762 Batch fermenter, 884–887 Batch heating and cooling of fluids, 636–654 Batch reactor, 220–223, 264, 457–473, 916, 919, 995–996, 1047–1072 BATCH software, 640–654 Benzene, 382, 382–390 Bhopal, 917 Biochemical reaction, 8, 9, 285, 830 Bioreactors, 831, 855, 868, 878, 884, 889–896 Blend time, 795, 801 Blending, 554 Blending time, 578 Bodenstein number, 732 Briggs-Haldane model, 840 Bromination of alkanes, 128 Buckingham’s theorem, 568 Bypassing, 688
C Calorimeters, 925, 941, 946 Catalytic isomerization of n-hexane, 290 Catalytic reactions, 21 Catalytic reactor, 232 Cell, 830 Cell growth, 863–865 Computational fluid dynamics (CFD), uses, 794 Chain length, 37–38, 54 Chain reactions, 16–20 Changing density gases, 162 Channeling, 688, 693 Characteristic velocity, 576 Chemical equilibrium, 60 Chemical kinetics, 109 Chemical potential, 61, 64, 69 Chemisorption, 29
1089
3321 - index
5/23/01
1090
1:50 PM
Page 1090
Modeling of Chemical Kinetics and Reactor Design
Chemostat, 873, 876–879 Clump, 764 Coefficients of process stability, 1039 Collision theory, 14–15 Comparison of ideal reactors, 387–395 Comparison of tank in series and dispersion models, 746 Competitive-consecutive reaction, 797 Competive inhibitors, 853 Complex reactions in a batch system, 292, 300–306 Computational fluid dynamics (CFD), 566, 609, 783 mixing (CFM), 566, 783 Conductimetry, 167 Consecutive reversible reactions, 288–291 Conservation of mass, 788 Constant density systems, 161 Continuous stirred tank reactor, 248 Continuous flow stirred tank reactor, 226, 312, 396–400, 906–1010 Continuous multiphase reactors, 230 Continuous plug (tubular) flow reactor, 227, 396–400 Conversion, 422, 764, 778 Cracking of alkanes, 5 Criteria for equilibrium, 63 Cumulative residence time distribution function, 666–667 Cycle time, 269 Cyclone separators, 234–235, 889
D Damköhler number, 729–730 Danckwerts boundary conditions, 743, 756 Deadspace (stagnancy), 688, 691 Decomposition, 519 Decomposition of benzene, 382–390 of ethane, 44–45 of nitrous oxide, 208–213 of phosphine, 378–380 of sulfuryl chloride, 205–207 Deep catalytic cracking unit, 235–238 Dehydration, 519 Design equation for heterogeneous reactions, 375–378 for systems of variable density, 372 Design of mixing systems, 656, 659 Desorption, 30 DIERS methodology, 936, 939, 950, 997 Differential method of analysis, 168
Differential reactor, 244 Digital particle image velocimetry, 786 Dilution rate, 874, 880, 883 Dimensional analysis, 566–569, 1040–1044 Dimensionless parameters, 592, 1036 Dimensionless variance in RTD, 720 Diphenyl, 387 Discharge system, 973, 976–978 of vent pipe, 973, 976–978 Dispersion coefficient, 728–729 Dispersion model, 723–729, 731–732 Dispersion of droplets, 554 Di-tertiary butyl peroxide, 943–945 Dynamic behavior of ideal systems, 400–410
E E-curves for a series of stirred tank reactors, 713–719 Eadie-Hofstee equation, 840 Eccentric angle, mixing, 565 Electrochemical methods, 167 Electron spin resonance spectroscopy, 163, 168 Elementary and non elementary reactions, 9–10, 42–43 Emulsion, 554 Endothermic reaction, 2, 81, 426, 429–430, 440, 1038 Energy balance for a batch reactor, 457 Energy balance for a tubular (plug) flow reactor, one dimension model, 472–477 for adiabatic tubular (plug) flow reactor, 476 in a continuous flow stirred tank reactor (CFSTR), 436–440 Energy conservation equation, 429 ENTHALP software (cgs unit), 80–85 ENTHALP1 software (S.I. Unit), 88 Enthalpy, 431 Enzyme catalyzed reactions, 21–25, 831–834 Enzymes catalysis, 831–839 Equal size CFSTR in series, 334–337 Equilibrium constant, 74–75, 427, 479, 481–483 Equilibrium rate method, 957 Esterification, 519, 855, 910 Esters, alkaline hydrolysis, 128 Ethane, 44–45 Ethyl nitrate, 46–49 Ethylene glycol production, 414–422, 917, 1045 Exothermic reaction, 2, 426, 429–430, 434, 504–508, 910, 916, 1038
3321 - index
5/23/01
1:50 PM
Page 1091
Index Exothermic reversible reaction, 508 Exotherms, 917, 928 Explosion, 910–911
1091
Guidelines to formulating reaction mechanism, 32–34
H F Fault tree analysis, 997 Fauske’s method, 966–968, 974–975 F-curves for a series of stirred tank reactors, 713–719 Fed batch reactor, 862, 887–888 Fermentation, 853 Fermentation process, 855 Fermenter jackets, 857, 862 Fibonacci optimization technique, RTD (PROG81), 722, 751 Fick’s law, 726 Fires, 910–911 First order reactions, 117 Fixed-bed reactor, 230, 811, 815 Flammable, 910 Flow maldistribution, 815 Flow pattern, mixing, 563–567 Flow recycle reactor, 410–414 Fluid catalytic cracking unit, 233, 234–235 Fluidized bed system, 232–233 Fractional conversion, 266–267, 271, 351 Free radicals, 44, 47 Friction factor, 497–500, 606 Froude number, 569 Fugacities, 65–66, 70 Fugacity coefficient, 67, 70, 427
G Gamma distribution function, 742, 755 Gas hourly space velocity, 351 Gas-solid catalytic reactions, 28 Gassing-in, 889 Gassing-out, 889 Gassy systems, 953–954, 959, 968 Gaussian distribution function, 742 Gibbs standard free energy, 426, 428 Gibbs-Duhem equation, 72 Glossary, biochemical reaction, 899–908 Glossary, Residence time distribution, 756–761 Glossary, Safety in chemical reaction engineering, 1010–1018 Gluconic acid, 8, 9, 830, 865–868 Glucose, 8, 9, 830, 833, 865–868 Glucose oxidase, 8, 9, 21, 832 Graphical solution of the cascade of N-CFSTR in series, 347 Grashof number, 627–628
Half-life, 120, 130–134 Halogenation, 910 Hazard analysis (HAZAN), 996 Hazard and operability studies (HAZOP), 991–996 Hazard rating chemical reactions, 1022–1033 Heat absorbed, 503 Heat capacities of gases, 80, 91, 104–108 Heat combustion, 102–103 Heat effect, 1038 Heat generated, 502–503, 515 Heat of reaction, 76–80, 82–85, 88–90 Heat transfer, 434 Heat transfer area, 628 coefficient, 622–628, 630–631, 990 in agitated vessels, 615–629 Heat transfer model scale-up, 1057–1063 predicting the temperature and time for, 1057–1062 Heats and Free energies of formation, 80–81, 94–101 Heaviside function, 686 Heterogeneous catalytic reactions, 233 Heterogeneous reactor, 231 Heterogeneous tubular reactor, 239, 371 Hexamine, 324 High-octane gasoline, 234 Homogeneous reactor, 227, 245 Homogeneous catalyzed reactions, 137–138 Homogeneous equilibrium method, 957 Homogeneous liquid phase, 26–27 Homogeneous two-phase venting, 970 Horsepower, 613–615 Hot spots, 234, 491 Hybrid systems, 954, 957, 959 Hydrocarbon molecules, 234 Hydrodesulfurizer, 753 Hydrogen peroxide, 833 Hydrogenation, 519 Hydrogenation of ethylene, 38–42 of nitrobenzene, 486–492 Hydrolysis, 855 Hydrolysis of acetic anhydride in a CFSTR, 452 of cobalt complex, 156 of methyl acetate, 199–201
3321 - index
5/23/01
1092
1:50 PM
Page 1092
Modeling of Chemical Kinetics and Reactor Design
Hydrolysis (continued) of urea, 833 Hydrolytic enzyme, 832
I Ideal gas mixtures, 65 Impellers, 557–561, 566–567, 581 Impulse signal, 680, 694, 705 Industrial reactors, 218 Infrared, 167 Inherently safe plants, 984–987 Inhibition, 838 Inhibitors, 834, 851–853 Integral method of analysis, 169 Intensity function, 670 Intensity of segregation, 553 Intermediate conversion of N-1 CFSTR, 341 Internal age distribution function, 668 Irreversible reactions, 129, 131, 140, 152, 315–316, 320 Isomerization, 519, 815, 832 Isothermal, 439, 446
J Jacket zoning of a batch reactor, scale-up, 1065, 1073
K k-ε model, 794, 817, 819, 825 Kenics mixer pressure drop, 601, 604–606, 610–612 specification, 603
L Laboratory reactors, 218, 1036 Lag phase, 864 Laminar flow in tubular reactor, RTD, 708–713 Lasser doppler velocimetry, 786 Least squares fitting, validity, 174–175 Leudeking-Piret kinetics, 886 Leung’s method, 974–975, 1001 Lewis-Randall rule, 66 Linear regression (PROG1), 171–173, 845 Lineweaver-Burk equation, 840–841, 846 Liquid hourly space velocity, 351 Liquid-solid agitation, 634–636 Longitudinal catalytic reactor, 232 Loop reactors, 254–255
M Macrofluid, 763, 767 Macromixing, 764, 769, 778
Mass spectrometry, 168 Mathematical modeling of the batch reactor, scale-up, 1044–1047, 1066 Maximum allowable working pressure, MAWP, 965, 981, 997 Maximum mixedness model, MMM, 772–774 Maximum reaction temperature, 924 Maximum venting pressure, 965 Mean residence time, 671–673, 694–695 Measurement of reaction rates, 155 Methanol synthesis, 425, 483–486, 543 Methyl-isocyanate, 916–917 Michaelis-Menten parameters, 24–25, 50–51, 836–839, 842–843 Microfluid, 553, 763 Micromixing, 764, 768–769 on conversion, effect of, 774–777 Microorganism, 830, 854 Minimum reactor volume at optimum temperature progression (OTP), 543 MIXER, software, 629 Mixing, 552, 783 Mixing time correlation, 578, 894 Mixing 2-D simulation, 802-805 3-D simulation, 808-809 Models for non-ideal systems, 762 Molds, 854 Mole fraction in the vapor phase, 481 Molecular diffusion, 552, 725 Moments in residence time distribution, 676–677, 679, 694–697 Monod constant, 875, 880 Multiple regression, PROG3, 189 Multi-stage continuous flow stirred tank reactor, 327–334
N Navier-Stokes equation, 791–794 Neutralization, 519 Newton-Raphson method for solving nonlinear equation, 326, 333, 338, 343 Nitration, 910 Nitric oxide, 42–43 Nomograph method, simplified two-phase flow relief system, 957, 961–962 Non competitive inhibitors, 853 Non-ideal systems, 762 Non-Isothermal reactors, 424 Nonlinear analysis, 173, 848 Normal stresses, 794
3321 - index
5/23/01
1:50 PM
Page 1093
Index Normalized residence time distribution function, 673–676 Nozzle reactors, 680 Nuclear magnetic resonance (NMR), 163, 179 Nuclear methods, 167 Nuclear radiation (radioisotopes), 168 Number of tanks in series, Residence time distribution (RTD), 686 Nusselt number, 627 Nutrients, 854, 865
O Octane number, 234 Off-centered position, mixing, 565 Onset temperature, 923 Optical methods, 166 Optimal design of non-isothermal reactors, 518–551 Optimization, 1045 Optimum reactor size, 546–547 Optimum temperature progression (OTP), 530–543 Overpressurization, 920 Oxidation, 519, 832, 855 Oxidative enzymes, 832 Oxygen transfer rate (OTR), 871–872, 889 Oxygen uptake rate (OUR), 871
P Packed-bed reactor, 230 Parallel reactions, 134–137 Parallel second order reactions, 291–295 Parametric sensitivity, 1046 Partial molar quantities, 72–74 Partial pressure, 160, 481 Peclet number, 729, 748–749 Penicillin, 889 Periodic input, 687 pH, 830, 834 PHI-TEC, 939–946 Pilot plant, 1035–1036 Pipe roughness of materials, 605 Plug (tubular) flow reactor, 362–371, 396–400, 472, 474–477 Polarimetry, 167 Polymerization, 519, 783, 910, 917 Polymerization kinetics, 20–21 Polynomial regression analysis, PROG2, 91 Post-processor, Computational fluid dynamics (CFD), 785 Potentiometry, 167 Power number, 569
1093
Power requirement for agitation, 566, 582–584, 589, 894 Prandtl number, 627 Pre-processor, Computational fluid dynamics (CFD), 784 Pressure drop in plug flow reactors, 414, 494–500, 817 Pressure effect, 429 Problems and errors in fitting rate models, 175 Process stability, 1046 Pseudo equilibrium, 30, 835 Pseudo order reaction, 154–155, 177, 179 Pseudo-steady state, 840 Pulse reactor, 252 Pumping number, 576 Pyrolysis of ethane, 51–58 of ethyl nitrate, 46–49
Q Quasi-steady state, 888
R Radial flow, 559, 815 Radial mixing, 600–601 Radioactive tracer, 702 Rate expressions, 1 Reaction equilibrium, 64, 69 Reaction mechanisms, 1 Reaction rate, determining, 168–177 Reactive system screening tool, 936–939 Reactor design, Introduction, 260 Reactor size and scale-up equations, 1043–1044 Reactors via Computational fluid dynamics, 811 Real gases—Ideal gaseous solution, 65 Recirculating transport reactor, 249, 251 Reduction, 855 Refractometry, 167 Regenerator, 223, 235, 236–237 Regression analysis, 49, 51 Relationships between the age distribution functions, 677 Relief device set pressure, 965 Residence time, 315 Residence time distribution (RTD) in flow reactors, 663, 665 Reversible reactions, 146–151, 317–318, 426 Reversible series reactions, 287–288 Reynolds number, 485, 569, 571–576, 627 Reynolds stresses, 794
3321 - index
5/23/01
1094
1:50 PM
Page 1094
Modeling of Chemical Kinetics and Reactor Design
RTD for a laminar flow tubular reactor, 708 from experimental tracer curves, 680 functions and their relationships, 664–671 functions for CSTRs where N is not an integer, 721 in a static mixer, 747 Rules of thumb, mixing, 654–656 Runaway reactions, 952–953 Runaway, thermal, 258, 916, 919, 921, 924 Runge-Kutta Gilll method (for solving differential equations), 868 Runge-Kutta method (for solving differential equations), 280, 287–288, 290, 292, 295, 298, 301, 305, 311, 385 Rupture (bursting) disc, 978–983 Rupture disk, 965, 978, 982–983
S Safety data sheet, 918 Saponification, 519 Scale of agitation, 576–577 of segregation, 552 Scale ratio, 585 Scale-up, 855, 889–895, 988–990, 1055–1056 factors, 1050–1051 in reactor design, 1034–1044 of a batch reactor, 1047–1072 heat transfer, 631–634 of mixing systems, 584–592 rule, 586–587 using mathematical modeling, 1044–1047 Schmidt number, 733 Screening thermal runaway conditions, method, 924–926 Second order reactions, 121–128, 320–322, 337–338 Segregated flow model, 764, 770–771 Selectivity, 351–360, 422 Self heat rate analysis, 931 Semibatch reactors, 222, 225–226, 306–313, 811, 916, 919 Series reactions, 280–285, 318 Series-parallel reactions, 415–422 Seveso, 258, 916 Shaft work, 435 Shear stresses, 794 Short-circuiting, 688 Similarity; geometric, kinematic, dynamic, 570, 592, 1037 SIMULAR, 946–950
Simultaneous irreversible side reactions, 152–154, 286–287 Slurry reactor, 240, 243 Solver, Computational fluid dynamics (CFD), 784 SOLVER, nonlinear analysis, 849 Space-time, 349–350 Space velocity, 349–350 Specific growth rate, 875 Stable intermediates, 10, 11 Stable operating conditions, 504, 506–507 Static mixers, 597–615, 747–749, 750 Steady state approximation, 53, 57 Steam cracking, 236–237 Steam reforming, 7, 8 Step change input, 684–686 Stirred batch reactor, 246 Stirred contained solids reactor, 246 Stoichiometry, 22, 121, 126, 141, 144, 183, 271, 448 Straight through transport reactor, 248, 250 Styrene mixture, 345–348, 997–999, 1002 Sublimation, 519 Substrate, 833 Substrate activation, 838 Sulfonation, 910 Sulfur dioxide oxidation, 6, 543 Surface reaction, 29 Surface stresses, 791 Suspension of fine particles, 554
T Tank in series (TIS), 713, 731 Taylor’s series, 265, 778 Temperature adjustment, scale-up, 1069–1072 Temperature effect, 429 Testing kinetic models, 34–37 The Gibbs function, 61 The Heaviside function, RTD, 686 The Helmholtz function, 62 Thermal behavior in flow systems, 500 of a tubular flow reactor, 507 Thermal dissociation of paraldehyde, 190–193 Thermodynamic data, 926 Thermodynamics, 59 first and second laws, 60, 63 Time average, turbulence on, 792–794 Time to maximum rate, 923, 929 Torque, 575 Total batch cycle time, 269 Total pressure, 481
3321 - index
5/23/01
1:50 PM
Page 1095
Index Toxic, 910, 917 Tracer experiments, interpretation of, 688–690 Transition state theory, 15–16 Trapezoidal method of area determination, 694–695 Treatment of Michaelis-Menten equation, 848–850 Trichlorophenol, 916 Trickle bed reactor, 240–243 Triphenyl, 387 Tubular (plug flow), two dimensional model, 492–494 Tubular reactors, 239, 492 Turbulence models, 794–795 Two-phase flow pressure drop in Static mixers, 615 Two-phase relief sizing, 950, 971–972 TWOPHASE, software, 615 Types of jacket construction, 617–618
U Ultraviolet, 166 Unstable operating condition, 504, 506–507 Unstable state energy balance for a CFSTR, 450–452 Urease, 21
Vapor pressure systems, 953, 959, 963 Variable coolant temperature in a CFSTR, 515–518 Variance, Residence time distribution (RTD), 694, 696 Vent pipe, design, 973–978 Vent sizing methods, 926, 940, 963–972 package, 934–936 Viable cells, 875 Voltammetry, 167 Vortex formation, 563–564
W Washout, 881–882 Water-gas shift reaction, 425 Weber number, 599 Weighted least squares analysis, 173 Working volume, 1048
Y Yeast, 854 Yield, 351
Z Zero order reactions, 116, 118
V Validity of least squares fitting, 174 van’t Hoffs equation, 75, 426, 429
1095
φ-Factor, 920–922, 928, 931