Table of Contents Chapter 1- Introduction Chapter 2 - Biomass (First-generation Technology) Chapter 3 - Hydroelectricity (First-generation technology) Chapter 4 - Geothermal Electricity (First-generation Technology) Chapter 5 - Solar Water Heating (Second-generation technology) Chapter 6 - Photovoltaics (Second-Generation Technology) Chapter 7 - Wind Power (Second-generation technology) Chapter 8 - Biomass Gasification (Third-generation technology) Chapter 9 - Enhanced Geothermal System (Third-Generation Technology)
Chapter-1 Introduction
The wind, Sun, and biomass are three renewable energy sources
Global renewable energy investment growth (1995–2007) Renewable energy commercialization involves the deployment of three generations of renewable energy technologies dating back more than 100 years. First-generation technologies, which are already mature and economically competitive, include biomass, hydroelectricity, geothermal power and heat. Second-generation technologies are marketready and are being deployed at the present time; they include solar heating, photovoltaics, wind power, solar thermal power stations, and modern forms of bioenergy. Third-generation technologies require continued R&D efforts in order to make large contributions on a global scale and include advanced biomass gasification, biorefinery technologies, hot-dry-rock geothermal power, and ocean energy. There are some non-technical barriers to the widespread use of renewables, and it is often public policy and political leadership that drive the widespread acceptance of renewable energy technologies. Some 85 countries now have targets for their own renewable energy futures, and have enacted wide-ranging public policies to promote renewables. Climate change concerns are driving increasing growth in the renewable energy industries. Leading renewable energy companies include First Solar, Gamesa, GE Energy, Q-Cells, Sharp Solar, Siemens, SunOpta, Suntech, and Vestas. Global revenues for solar photovoltaics, wind power, and biofuels expanded from $76 billion in 2007 to $115 billion in 2008. New global investments in clean energy technologies—including venture capital, project finance, public markets, and research and development—expanded by 4.7 percent from $148 billion in 2007 to $155 billion in 2008. Continued growth for the renewable energy sector is expected and promotional policies helped the industry weather the 2009 economic crisis better than many other
sectors. U.S. President Barack Obama's American Recovery and Reinvestment Act of 2009 included more than $70 billion in direct spending and tax credits for clean energy and associated transportation programs. Clean Edge suggests that the commercialization of clean energy has helped countries around the world pull out of the 2009 global financial crisis. Globally, there are an estimated 3 million direct jobs in renewable energy industries, with about half of them in the biofuels industry.
Overview Rationale for renewables Renewable energy technologies are essential contributors to the energy supply portfolio, as they contribute to world energy security, reduce dependency on fossil fuels, and provide opportunities for mitigating greenhouse gases. Climate-disrupting fossil fuels are being replaced by clean, climate-stabilizing, non-depletable sources of energy: ...the transition from coal, oil, and gas to wind, solar, and geothermal energy is well under way. In the old economy, energy was produced by burning something — oil, coal, or natural gas — leading to the carbon emissions that have come to define our economy. The new energy economy harnesses the energy in wind, the energy coming from the sun, and heat from within the earth itself. The International Energy Agency estimates that nearly 50% of global electricity supplies will need to come from renewable energy sources in order to halve carbon dioxide emissions by 2050 and minimise significant, irreversible climate change impacts.
Three generations of technologies The term renewable energy covers a number of sources and technologies at different stages of commercialization. The International Energy Agency (IEA) has defined three generations of renewable energy technologies, reaching back over 100 years: •
First-generation technologies emerged from the industrial revolution at the end of the 19th century and include hydropower, biomass combustion, geothermal power and heat. These technologies are quite widely used.
•
Second-generation technologies include solar heating and cooling, wind power, modern forms of bioenergy, and solar photovoltaics. These are now entering markets as a result of research, development and demonstration (RD&D) investments since the 1980s. Initial investment was prompted by energy security concerns linked to the oil crises of the 1970s but the enduring appeal of these technologies is due, at least in part, to environmental benefits. Many of the technologies reflect significant advancements in materials.
•
Third-generation technologies are still under development and include advanced biomass gasification, biorefinery technologies, concentrating solar thermal power,
hot-dry-rock geothermal power, and ocean energy. Advances in nanotechnology may also play a major role. First-generation technologies are well established, second-generation technologies are entering markets, and third-generation technologies heavily depend on long-term RD&D commitments, where the public sector has a role to play.
Recent growth of renewables During the five-years from the end of 2004 through 2009, worldwide renewable energy capacity grew at rates of 10–60 percent annually for many technologies. For wind power and many other renewable technologies, growth accelerated in 2009 relative to the previous four years. More wind power capacity was added during 2009 than any other renewable technology. However, grid-connected PV increased the fastest of all renewables technologies, with a 60 percent annual average growth rate for the five-year period. Selected renewable energy indicators Selected global indicators 2004 2005 2006 2007 2008 2009 Investment in new renewable capacity 150 billion 30 38 63 104 130 (annual) USD Existing renewables power capacity, 895 930 1,020 1,070 1,140 1,230 GWe including large-scale hydro Existing renewables power capacity, 160 182 207 240 280 305 GWe excluding large hydro Wind power capacity (existing) 48 59 74 94 121 159 GWe Solar PV capacity (grid-connected) 7.6 13.5 21 GWe Solar hot water capacity 77 88 105 126 149 180 GWth Ethanol production (annual) 30.5 33 39 50 69 76 billion liters Biodiesel production (annual) 10 15 17 billion liters Countries with policy targets 45 49 68 75 85 for renewable energy use In 2008 for the first time, more renewable energy than conventional power capacity was added in both the European Union and United States, demonstrating a "fundamental transition" of the world's energy markets towards renewables, according to a report released by REN21, a global renewable energy policy network based in Paris. A 2010 survey conducted by Applied Materials shows that two-thirds of Americans believe solar technology should play a greater role in meeting the country's energy needs. In addition, "three-quarters of Americans feel that increasing renewable energy and decreasing U.S. dependence on foreign oil are the country's top energy priorities". According to the survey, "67 percent of Americans would be willing to pay more for their monthly utility bill if their utility company increased its use of renewable energy".
Economic trends The International Solar Energy Society argues that renewable energy technologies and economics will improve with time, and that they are "sufficiently advanced at present to allow for major penetrations of renewable energy into the mainstream energy and societal infrastructures". Indicative, levelised, economic costs for renewable power (exclusive of subsidies or policy incentives) are shown in the Table below. Renewable power generation costs 2010 Power generator Large hydro Small hydro Onshore wind Offshore wind Biomass power Geothermal power Rooftop solar PV Utility-scale solar PV Concentrating solar thermal power (CSP)
Typical characteristics Plant size: 10 - 18,000 MW Plant size: 1-10 MW Turbine size: 1.5 - 3.5 MW Turbine size: 1.5 - 5 MW Plant size: 1-20 MW Plant size: 1-100 MW Peak capacity: 2-5 kilowattspeak Peak capacity: 200 kW to 100MW 50-500 MW trough
Typical electricity costs (U.S. cents/kWh) 3-5 5-12 5-9 10-14 5-12 4-7 20-50 15-30 14-18
As time progresses, renewable energy generally gets cheaper, while fossil fuels generally get more expensive. Al Gore has explained that renewable energy technologies are declining in price for three main reasons: First, once the renewable infrastructure is built, the fuel is free forever. Unlike carbonbased fuels, the wind and the sun and the earth itself provide fuel that is free, in amounts that are effectively limitless. Second, while fossil fuel technologies are more mature, renewable energy technologies are being rapidly improved. So innovation and ingenuity give us the ability to constantly increase the efficiency of renewable energy and continually reduce its cost. Third, once the world makes a clear commitment to shifting toward renewable energy, the volume of production will itself sharply reduce the cost of each windmill and each solar panel, while adding yet more incentives for additional research and development to further speed up the innovation process.
First-generation technologies First-generation technologies are widely used in locations with abundant resources. Their future use depends on the exploration of the remaining resource potential, particularly in developing countries, and on overcoming challenges related to the environment and social acceptance.
Biomass
Biomass heating plant in Austria. The total heat power is about 1000 kW. Biomass for heat and power is a fully mature technology which offers a ready disposal mechanism for municipal, agricultural, and industrial organic wastes. However, the
industry has remained relatively stagnant over the decade to 2007, even though demand for biomass (mostly wood) continues to grow in many developing countries. One of the problems of biomass is that material directly combusted in cook stoves produces pollutants, leading to severe health and environmental consequences, although improved cook stove programmes are alleviating some of these effects. First-generation biomass technologies can be economically competitive, but may still require deployment support to overcome public acceptance and small-scale issues.
Hydroelectricity
The Hoover Dam when completed in 1936 was both the world's largest electric-power generating station and the world's largest concrete structure. Hydroelectric plants have the advantage of being long-lived and many existing plants have operated for more than 100 years. Hydropower is also an extremely flexible technology from the perspective of power grid operation. Large hydropower provides one of the lowest cost options in today’s energy market, even compared to fossil fuels and there are no harmful emissions associated with plant operation. Hydroelectric power is currently the world’s largest installed renewable source of electricity, supplying about 17% of total electricity in 2005. China is the world's largest producer of hydroelectricity in the world, followed by Canada.
However, there are several significant social and environmental disadvantages of largescale hydroelectric power systems: dislocation of people living where the reservoirs are planned, release of significant amounts of carbon dioxide and methane during construction and flooding of the reservoir, and disruption of aquatic ecosystems and birdlife. Hydroelectric power is now more difficult to site in developed nations because most major sites within these nations are either already being exploited or may be unavailable for these environmental reasons. The areas of greatest hydroelectric growth are the growing economies of Asia. India and China are the development leaders; however, other Asian nations are also expanding hydropower. There is a strong consensus now that countries should adopt an integrated approach towards managing water resources, which would involve planning hydropower development in co-operation with other water-using sectors.
Geothermal power and heat
One of many power plants at The Geysers, a geothermal power field in northern California, with a total output of over 750 MW Geothermal power plants can operate 24 hours per day, providing baseload capacity. Estimates for the world potential capacity for geothermal power generation vary widely, ranging from 40 GW by 2020 to as much as 6,000 GW. Geothermal power capacity grew from around 1 GW in 1975 to almost 10 GW in 2008. The United States is the world leader in terms of installed capacity, representing 3.1 GW. Other countries with significant installed capacity include the Philippines (1.9 GW), Indonesia (1.2 GW), Mexico (1.0 GW), Italy (0.8 GW), Iceland (0.6 GW), Japan (0.5 GW), and New Zealand (0.5 GW). In some countries, geothermal power accounts for a
significant share of the total electricity supply, such as in the Philippines, where geothermal represented 17 percent of the total power mix at the end of 2008. Geothermal (ground source) heat pumps represented an estimated 30 GWth of installed capacity at the end of 2008, with other direct uses of geothermal heat (i.e., for space heating, agricultural drying and other uses) reaching an estimated 15 GWth. As of 2008, at least 76 countries use direct geothermal energy in some form.
Second-generation technologies Markets for second-generation technologies have been strong and growing over the past decade, and these technologies have gone from being a passion for the dedicated few to a major economic sector in countries such as Germany, Spain, the United States, and Japan. Many large industrial companies and financial institutions are involved and the challenge is to broaden the market base for continued growth worldwide.
Solar Heating
Solar energy technologies, such as solar water heaters, located on or near the buildings which they supply with energy, are a prime example of a soft energy technology.
Solar heating systems are a well known second-generation technology and generally consist of solar thermal collectors, a fluid system to move the heat from the collector to its point of usage, and a reservoir or tank for heat storage. The systems may be used to heat domestic hot water, swimming pools, or homes and businesses. The heat can also be used for industrial process applications or as an energy input for other uses such as cooling equipment. In many warmer climates, a solar heating system can provide a very high percentage (50 to 75%) of domestic hot water energy. As of 2009, China has 27 million rooftop solar water heaters.
Photovoltaics
Nellis Solar Power Plant at Nellis Air Force Base. These panels track the sun in one axis.
President Barack Obama speaks at the DeSoto Next Generation Solar Energy Center. Photovoltaic (PV) cells, also called solar cells, convert light into electricity. In the 1980s and early 1990s, most photovoltaic modules were used to provide remote-area power supply, but from around 1995, industry efforts have focused increasingly on developing building integrated photovoltaics and photovoltaic power stations for grid connected applications. In particularly sunny regions such as Spain, the Middle East, North Africa, the southern USA, India, and parts of China, modern solar modules are close to achieving grid parity. And in countries situated further to the north such as Germany, France, and the Czech Republic, grid parity is expected by 2015. Falling technology prices and the rising costs of fossil fuels are making photovoltaic (PV) power plants increasingly attractive for large investors. As of November 2010, the largest photovoltaic power plants in the world are the Finsterwalde Solar Park (Germany, 80.7 MW), Sarnia Photovoltaic Power Plant (Canada, 80 MW), Olmedilla Photovoltaic Park (Spain, 60 MW), the Strasskirchen Solar Park (Germany, 54 MW), the Lieberose Photovoltaic Park (Germany, 53 MW), and the Puertollano Photovoltaic Park (Spain, 50 MW). Some photovoltaic power stations which are presently proposed will have a capacity of 150 MW or more. At the end of 2008, the cumulative global PV installations reached 15,200 MW. Photovoltaic production has been doubling every two years, increasing by an average of 48 percent each year since 2002, making it the world’s fastest-growing energy technology. The top five photovoltaic producing countries are Japan, China, Germany, Taiwan, and the USA.
Wind power
Worldwide installed wind power capacity 1996-2008
Fenton Wind Farm at sunrise
Some of the second-generation renewables, such as wind power, have high potential and have already realised relatively low production costs. At the end of 2009, worldwide wind farm capacity was 157,900 MW, representing an increase of 31 percent during the year, and wind power supplied some 1.3% of global electricity consumption. Wind power is widely used in European countries, and more recently in the United States and Asia. Wind power accounts for approximately 19% of electricity generation in Denmark, 11% in Spain and Portugal, and 9% in the Republic of Ireland. These are some of the largest wind farms in the world, as of July 2010: Installed capacity Country (MW) Capricorn Ridge Wind Farm 662 USA Fowler Ridge Wind Farm 600 USA Horse Hollow Wind Energy Center 736 USA Roscoe Wind Farm 781 USA San Gorgonio Pass Wind Farm 619 USA Tehachapi Pass Wind Farm 690 USA Wind farm
Solar thermal power stations
Solar Towers from left: PS10, PS20.
Solar thermal power stations include the 354 megawatt (MW) Solar Energy Generating Systems power plant in the USA, Solnova Solar Power Station (Spain, 150 MW), Andasol solar power station (Spain, 100 MW), Nevada Solar One (USA, 64 MW), PS20 solar power tower (Spain, 20 MW), and the PS10 solar power tower (Spain, 11 MW). The 370 MW Ivanpah Solar Power Facility, located in California's Mojave Desert, is the world’s largest solar-thermal power plant project currently under construction. Many other plants are under construction or planned, mainly in Spain and the USA. In developing countries, three World Bank projects for integrated solar thermal/combinedcycle gas-turbine power plants in Egypt, Mexico, and Morocco have been approved.
Modern forms of Bioenergy
Neat ethanol on the left (A), gasoline on the right (G) at a filling station in Brazil. Global ethanol production for transport fuel tripled between 2000 and 2007 from 17 billion to more than 52 billion litres, while biodiesel expanded more than tenfold from less than 1 billion to almost 11 billion litres. Biofuels provide 1.8% of the world’s transport fuel and recent estimates indicate a continued high growth. The main producing countries for transport biofuels are the USA, Brazil, and the EU. Brazil has one of the largest renewable energy programs in the world, involving production of ethanol fuel from sugar cane, and ethanol now provides 18 percent of the country's automotive fuel. As a result of this and the exploitation of domestic deep water
oil sources, Brazil, which for years had to import a large share of the petroleum needed for domestic consumption, recently reached complete self-sufficiency in liquid fuels.
Information on pump, California Nearly all the gasoline sold in the United States today is mixed with 10 percent ethanol, a mix known as E10, and motor vehicle manufacturers already produce vehicles designed to run on much higher ethanol blends. Ford, DaimlerChrysler, and GM are among the automobile companies that sell flexible-fuel cars, trucks, and minivans that can use gasoline and ethanol blends ranging from pure gasoline up to 85% ethanol (E85). By mid-2006, there were approximately six million E85-compatible vehicles on U.S. roads. The challenge is to expand the market for biofuels beyond the farm states where they have been most popular to date. Flex-fuel vehicles are assisting in this transition because they allow drivers to choose different fuels based on price and availability. The Energy Policy Act of 2005, which calls for 7.5 billion gallons of biofuels to be used annually by 2012, will also help to expand the market. The growing ethanol and biodiesel industries are providing jobs in plant construction, operations, and maintenance, mostly in rural communities. According to the Renewable Fuels Association, the ethanol industry created almost 154,000 U.S. jobs in 2005 alone, boosting household income by $5.7 billion. It also contributed about $3.5 billion in tax revenues at the local, state, and federal levels.
Third-generation technologies Third-generation renewable energy technologies are still under development and include advanced biomass gasification, biorefinery technologies, hot-dry-rock geothermal power, and ocean energy. Third-generation technologies are not yet widely demonstrated or have limited commercialization. Many are on the horizon and may have potential comparable to other renewable energy technologies, but still depend on attracting sufficient attention and RD&D funding.
New bioenergy technologies According to the International Energy Agency, cellulosic ethanol biorefineries could allow biofuels to play a much bigger role in the future than organizations such as the IEA previously thought. Cellulosic ethanol can be made from plant matter composed primarily of inedible cellulose fibers that form the stems and branches of most plants. Crop residues (such as corn stalks, wheat straw and rice straw), wood waste, and municipal solid waste are potential sources of cellulosic biomass. Dedicated energy crops, such as switchgrass, are also promising cellulose sources that can be sustainably produced in many regions of the United States. Selected Commercial Cellulosic Ethanol Plants in the U.S. (Operational or under construction) Company Location Feedstock Abengoa Bioenergy Hugoton, KS Wheat straw BlueFire Ethanol Irvine, CA Multiple sources Gulf Coast Energy Mossy Head, FL Wood waste Mascoma Lansing, MI Wood POET LLC Emmetsburg, IA Corn cobs Range Fuels Treutlen County, GA Wood waste SunOpta Little Falls, MN Wood chips Xethanol Auburndale, FL Citrus peels
Ocean energy The Rance Tidal Power Station (240 MW) is the world's first tidal power station. The facility is located on the estuary of the Rance River, in Brittany, France. Opened on the 26th November 1966, it is currently operated by Électricité de France, and is the largest tidal power station in the world, in terms of installed capacity. First proposed more than thirty years ago, systems to harvest utility-scale electrical power from ocean waves have recently been gaining momentum as a viable technology. The potential for this technology is considered promising, especially on west-facing coasts with latitudes between 40 and 60 degrees:
In the United Kingdom, for example, the Carbon Trust recently estimated the extent of the economically viable offshore resource at 55 TWh per year, about 14% of current national demand. Across Europe, the technologically achievable resource has been estimated to be at least 280 TWh per year. In 2003, the U.S. Electric Power Research Institute (EPRI) estimated the viable resource in the United States at 255 TWh per year (6% of demand). Funding for a wave farm in Scotland was announced in February 2007 by the Scottish Executive, at a cost of over 4 million pounds, as part of a £13 million funding packages for ocean power in Scotland. The farm will be the world's largest with a capacity of 3 MW generated by four Pelamis machines.
Enhanced geothermal systems As of 2008, geothermal power development was under way in more than 40 countries, partially attributable to the development of new technologies, such as Enhanced Geothermal Systems. The development of binary cycle power plants and improvements in drilling and extraction technology may enable enhanced geothermal systems over a much greater geographical range than "traditional" Geothermal systems. Demonstration EGS projects are operational in the USA, Australia, Germany, France, and The United Kingdom.
Nanotechnology thin-film solar panels Solar power panels that use nanotechnology, which can create circuits out of individual silicon molecules, may cost half as much as traditional photovoltaic cells, according to executives and investors involved in developing the products. Nanosolar has secured more than $100 million from investors to build a factory for nanotechnology thin-film solar panels. The company expects the factory to open in 2010 and produce enough solar cells each year to generate 430 megawatts of power.
Renewable energy industry
A Vestas wind turbine
Gamesa Wind Turbine Installed at Bald Mountain in Bear Creek Township, PA
Monocrystalline solar cell Global revenues for solar photovoltaics, wind power, and biofuels expanded from $76 billion in 2007 to $115 billion in 2008. New global investments in clean energy technologies — including venture capital, project finance, public markets, and research and development — expanded by 4.7 percent from $148 billion in 2007 to $155 billion in 2008.
Wind power companies Vestas is the largest wind turbine manufacturer in the world with a 20% market share in 2008. The company operates plants in Denmark, Germany, India, Italy, Britain, Spain, Sweden, Norway, Australia and China, and employs more than 20,000 people globally.
After a sales slump in 2005, Vestas recovered and was voted Top Green Company of 2006. Vestas announced a major expansion of its North American headquarters in Portland, Oregon in December, 2008. GE Energy was the world's second largest wind turbine manufacturer in 2008, with 19% market share. The company has installed over 5,500 wind turbines and 3,600 hydro turbines, and its installed capacity of renewable energy worldwide exceeds 160,000 MW. GE Energy bought out Enron Wind in 2002 and also has nuclear energy operations in its portfolio. Gamesa, founded in 1976 with headquarters in Vitoria, Spain, was the world's third largest wind turbine manufacturer in 2008, and it is also a major builder of wind farms. Gamesa’s main markets are within Europe, the US and China. Other major wind power companies include Siemens, Suzlon, Sinovel and Goldwind.
Photovoltaic companies First Solar became the world's largest solar cell maker in 2009, producing some 1,100 MW of product, with a 13% market share. Suntech was in second place with production of 595 MW in 2009 and market share of 7%. Sharp was close behind the leaders with 580 MW of output. Q-Cells and its 540 MW output was fourth in 2009. Yingli Green Energy, JA Solar Holdings, SunPower, Kyocera, Motech Solar and Gintech rounded out the 2009 Top 10 ranking.
Non-technical barriers to acceptance Newer and cleaner technologies may offer social and environmental benefits, but utility operators often reject renewable resources because they are trained to think only in terms of big, conventional power plants. Consumers often ignore renewable power systems because they are not given accurate price signals about electricity consumption. Intentional market distortions (such as subsidies), and unintentional market distortions (such as split incentives) may work against renewables. Benjamin K. Sovacool has argued that "some of the most surreptitious, yet powerful, impediments facing renewable energy and energy efficiency in the United States are more about culture and institutions than engineering and science". The obstacles to the widespread commercialization of renewable energy technologies are primarily political, not technical, and there have been many studies which have identified a range of "non-technical barriers" to renewable energy use. These barriers are impediments which put renewable energy at a marketing, institutional, or policy disadvantage relative to other forms of energy. Key barriers include: •
Lack of government policy support, which includes the lack of policies and regulations supporting deployment of renewable energy technologies and the presence of policies and regulations hindering renewable energy development and
• • •
supporting conventional energy development. Examples include subsidies for fossil-fuels, insufficient consumer-based renewable energy incentives, government underwriting for nuclear plant accidents, and complex zoning and permitting processes for renewable energy. Lack of information dissemination and consumer awareness. Higher capital cost of renewable energy technologies compared with conventional energy technologies. Difficulty overcoming established energy systems, which includes difficulty introducing innovative energy systems, particularly for distributed generation such as photovoltaics, because of technological lock-in, electricity markets designed for centralized power plants, and market control by established operators. As the Stern Review on the Economics of Climate Change points out: National grids are usually tailored towards the operation of centralised power plants and thus favour their performance. Technologies that do not easily fit into these networks may struggle to enter the market, even if the technology itself is commercially viable. This applies to distributed generation as most grids are not suited to receive electricity from many small sources. Large-scale renewables may also encounter problems if they are sited in areas far from existing grids.
•
•
•
• • •
Inadequate financing options for renewable energy projects, including insufficient access to affordable financing for project developers, entrepreneurs and consumers. Imperfect capital markets, which includes failure to internalize all costs of conventional energy (e.g., effects of air pollution, risk of supply disruption) and failure to internalize all benefits of renewable energy (e.g., cleaner air, energy security). Inadequate workforce skills and training, which includes lack of adequate scientific, technical, and manufacturing skills required for renewable energy production; lack of reliable installation, maintenance, and inspection services; and failure of the educational system to provide adequate training in new technologies. Lack of adequate codes, standards, utility interconnection, and net-metering guidelines. Poor public perception of renewable energy system aesthetics. Lack of stakeholder/community participation and co-operation in energy choices and renewable energy projects.
With such a wide range of non-technical barriers, there is no "silver bullet" solution to drive the transition to renewable energy. So ideally there is a need for several different types of policy instruments to complement each other and overcome different types of barriers. A policy framework must be created that will level the playing field and redress the imbalance of traditional approaches associated with fossil fuels. The policy landscape
must keep pace with broad trends within the energy sector, as well as reflecting specific social, economic and environmental priorities.
Public policy landscape Public policy has a role to play in renewable energy commercialization because the free market system has some fundamental limitations. As the Stern Review points out: In a liberalised energy market, investors, operators and consumers should face the full cost of their decisions. But this is not the case in many economies or energy sectors. Many policies distort the market in favour of existing fossil fuel technologies. The International Solar Energy Society has stated that "historical incentives for the conventional energy resources continue even today to bias markets by burying many of the real societal costs of their use". Lester Brown goes further and suggests that the market "does not incorporate the indirect costs of providing goods or services into prices, it does not value nature’s services adequately, and it does not respect the sustainable-yield thresholds of natural systems". It also favors the near term over the long term, thereby showing limited concern for future generations. Tax and subsidy shifting can help overcome these problems.
Shifting taxes Tax shifting involves lowering income taxes while raising levies on environmentally destructive activities, in order to create a more responsive market. It has been widely discussed and endorsed by economists. For example, a tax on coal that included the increased health care costs associated with breathing polluted air, the costs of acid rain damage, and the costs of climate disruption would encourage investment in renewable technologies. Several Western European countries are already shifting taxes in a process known there as environmental tax reform, to achieve environmental goals. A four-year plan adopted in Germany in 1999 gradually shifted taxes from labor to energy and, by 2001, this plan had lowered fuel use by 5 percent. It had also increased growth in the renewable energy sector, creating some 45,400 jobs by 2003 in the wind industry alone, a number that is projected to rise to 103,000 by 2010. In 2001, Sweden launched a new 10-year environmental tax shift designed to convert 30 billion kroner ($3.9 billion) of taxes on income to taxes on environmentally destructive activities. Other European countries with significant tax reform efforts are France, Italy, Norway, Spain, and the United Kingdom. Asia’s two leading economies, Japan and China, are considering the adoption of carbon taxes.
Shifting subsidies Subsidies are not inherently bad as many technologies and industries emerged through government subsidy schemes. The Stern Review explains that of 20 key innovations from
the past 30 years, only one of the 14 they could source was funded entirely by the private sector and nine were totally funded by the public sector. In terms of specific examples, the Internet was the result of publicly funded links among computers in government laboratories and research institutes. And the combination of the federal tax deduction and a robust state tax deduction in California helped to create the modern wind power industry. But just as there is a need for tax shifting, there is also a need for subsidy shifting. Lester Brown has argued that "a world facing the prospect of economically disruptive climate change can no longer justify subsidies to expand the burning of coal and oil. Shifting these subsidies to the development of climate-benign energy sources such as wind, solar, biomass, and geothermal power is the key to stabilizing the earth’s climate." The International Solar Energy Society advocates "leveling the playing field" by redressing the continuing inequities in public subsidies of energy technologies and R&D, in which the fossil fuel and nuclear power receive the largest share of financial support. Some countries are eliminating or reducing climate disrupting subsidies and Belgium, France, and Japan have phased out all subsidies for coal. Germany reduced its coal subsidy from $5.4 billion in 1989 to $2.8 billion in 2002, and in the process lowered its coal use by 46 percent. Germany plans to phase out this support entirely by 2010. China cut its coal subsidy from $750 million in 1993 to $240 million in 1995 and more recently has imposed a tax on high-sulfur coals. While some leading industrial countries have been reducing subsidies to fossil fuels, most notably coal, the United States has been increasing its support for the fossil fuel and nuclear industries.
Renewable energy targets Setting national renewable energy targets can be an important part of a renewable energy policy and these targets are usually defined as a percentage of the primary energy and/or electricity generation mix. For example, the European Union has prescribed an indicative renewable energy target of 12 per cent of the total EU energy mix and 22 per cent of electricity consumption by 2010. National targets for individual EU Member States have also been set to meet the overall target. Other developed countries with defined national or regional targets include Australia, Canada, Japan, New Zealand, Norway, Switzerland, and some US States. National targets are also an important component of renewable energy strategies in some developing countries. Developing countries with renewable energy targets include China, India, Korea, Indonesia, Malaysia, the Philippines, Singapore, Thailand, Brazil, Israel, Egypt, Mali, and South Africa. The targets set by many developing countries are quite modest when compared with those in some industrialized countries. Renewable energy targets in most countries are indicative and nonbinding but they have assisted government actions and regulatory frameworks. The United Nations
Environment Program has suggested that making renewable energy targets legally binding could be an important policy tool to achieve higher renewable energy market penetration.
Green stimulus programs In response to the global financial crisis, the world’s major governments have made “green stimulus” programs one of their main policy instruments for supporting the economic recovery. Some $188 billion in green stimulus funding had been allocated to renewable energy and energy efficiency. Most of the overall clean energy stimuli are expected to be spent in 2010 and in 2011.
Employment Current employment in the renewable energy sector and supplier industries is estimated at 2.3 million worldwide. The wind power industry employs some 300,000 people, the photovoltaics sector an estimated 170,000, and the solar thermal industry more than 600,000. Over 1 million jobs are found in the biofuels industry, associated with growing and processing a variety of feedstocks into ethanol and biodiesel.
Recent developments
Projected renewable energy investment growth globally (2007-2017) A number of events in 2006 pushed renewable energy up the political agenda, including the US mid-term elections in November, which confirmed clean energy as a mainstream issue. Also in 2006, the Stern Review made a strong economic case for investing in low carbon technologies now, and argued that economic growth need not be incompatible with cutting energy consumption. According to a trend analysis from the United Nations
Environment Programme, climate change concerns coupled with recent high oil prices and increasing government support are driving increasing rates of investment in the renewable energy and energy efficiency industries. Investment capital flowing into renewable energy reached a record US$77 billion in 2007, with the upward trend continuing in 2008. The OECD still dominates, but there is now increasing activity from companies in China, India and Brazil. Chinese companies were the second largest recipient of venture capital in 2006 after the United States. In the same year, India was the largest net buyer of companies abroad, mainly in the more established European markets. Global revenues for solar photovoltaics, wind power, and biofuels expanded from $75.8 billion in 2007 to $115.9 billion in 2008. For the first time, one sector alone, wind, had revenues exceeding $50 billion. New global investments in clean energy technologies — including venture capital, project finance, public markets, and research and development — expanded by 4.7 percent from $148.4 billion in 2007 to $155.4 billion in 2008. After several years with strong political backing and growth, 2009 was a year of refocus, consolidation, or retrenchment for many companies. However, new wind power capacity installed in 2009 grew strongly with record installations of 38 GW worldwide, partly as a result of the rapid rise of Chinese manufacturing. New government spending, regulation, and policies helped the industry weather the 2009 economic crisis better than many other sectors. Most notably, U.S. President Barack Obama's American Recovery and Reinvestment Act of 2009 included more than $70 billion in direct spending and tax credits for clean energy and associated transportation programs. This policy-stimulus combination represents the largest federal commitment in U.S. history for renewables, advanced transportation, and energy conservation initiatives. Based on these new rules, many more utilities strengthened their clean-energy programs. Clean Edge suggests that the commercialization of clean energy will help countries around the world pull out of the current economic malaise.
Sustainable energy Moving towards energy sustainability will require changes not only in the way energy is supplied, but in the way it is used, and reducing the amount of energy required to deliver various goods or services is essential. Opportunities for improvement on the demand side of the energy equation are as rich and diverse as those on the supply side, and often offer significant economic benefits. Renewable energy and energy efficiency are said to be the “twin pillars” of sustainable energy policy. Any serious vision of a sustainable energy economy requires commitments to both renewables and efficiency. The American Council for an Energy-Efficient Economy has explained that both resources must be developed in order to stabilize and reduce carbon dioxide emissions:
Efficiency is essential to slowing the energy demand growth so that rising clean energy supplies can make deep cuts in fossil fuel use. If energy use grows too fast, renewable energy development will chase a receding target. Likewise, unless clean energy supplies come online rapidly, slowing demand growth will only begin to reduce total emissions; reducing the carbon content of energy sources is also needed. The IEA has stated that renewable energy and energy efficiency policies should be viewed as complementary tools for the development of a sustainable energy future, instead of being developed in isolation.
Chapter-2 Biomass (First-generation Technology)
Biomass, a renewable energy source, is biological material from living, or recently living organisms, such as wood, waste, (hydrogen) gas, and alcohol fuels. Biomass is commonly plant matter grown to generate electricity or produce heat. In this sense, living biomass can also be included, as plants can also generate electricity while still alive. The most conventional way in which biomass is used however, still relies on direct incineration. Forest residues for example (such as dead trees, branches and tree stumps), yard clippings, wood chips and garbage are often used for this. However, biomass also includes plant or animal matter used for production of fibers or chemicals. Biomass may also include biodegradable wastes that can be burnt as fuel. It excludes organic materials such as fossil fuels which have been transformed by geological processes into substances such as coal or petroleum. Industrial biomass can be grown from numerous types of plants, including miscanthus, switchgrass, hemp, corn, poplar, willow, sorghum, sugarcane, and a variety of tree species, ranging from eucalyptus to oil palm (palm oil). The particular plant used is usually not important to the end products, but it does affect the processing of the raw material. Although fossil fuels have their origin in ancient biomass, they are not considered biomass by the generally accepted definition because they contain carbon that has been "out" of the carbon cycle for a very long time. Their combustion therefore disturbs the carbon dioxide content in the atmosphere.
Chemical composition Biomass is carbon, hydrogen and oxygen based. Nitrogen and small quantities of other atoms, including alkali, alkaline earth and heavy metals can be found as well. Metals are often found in functional molecules such as the porphyrins which include chlorophyll which contains magnesium.
Plants in particular combine water and carbon dioxide to sugar building blocks. The required energy is produced from light via photosynthesis based on chlorophyll. On average, between 0.1 and 1 % of the available light is stored as chemical energy in plants. The sugar building blocks are the starting point for the major fractions found in all terrestrial plants, lignin, hemicellulose and cellulose.
Biomass sources Biomass energy is derived from five distinct energy sources: garbage, wood, waste, landfill gases, and alcohol fuels. Wood energy is derived both from direct use of harvested wood as a fuel and from wood waste streams. The largest source of energy from wood is pulping liquor or “black liquor,” a waste product from processes of the pulp, paper and paperboard industry. Waste energy is the second-largest source of biomass energy. The main contributors of waste energy are municipal solid waste (MSW), manufacturing waste, and landfill gas. Biomass alcohol fuel, or ethanol, is derived primarily from sugarcane and corn. It can be used directly as a fuel or as an additive to gasoline. Biomass can be converted to other usable forms of energy like methane gas or transportation fuels like ethanol and biodiesel. Rotting garbage, and agricultural and human waste, release methane gas - also called "landfill gas" or "biogas." Crops like corn and sugar cane can be fermented to produce the transportation fuel, ethanol. Biodiesel, another transportation fuel, can be produced from left-over food products like vegetable oils and animal fats. Also, Biomass to liquids (BTLs) and cellulosic ethanol are still under research.
Biomass conversion process to useful energy There are a number of technological options available to make use of a wide variety of biomass types as a renewable energy source. Conversion technologies may release the energy directly, in the form of heat or electricity, or may convert it to another form, such as liquid biofuel or combustible biogas. While for some classes of biomass resource there may be a number of usage options, for others there may be only one appropriate technology.
Thermal conversion These are processes in which heat is the dominant mechanism to convert the biomass into another chemical form. The basic alternatives of combustion, torrefaction, pyrolysis, and gasification are separated principally by the extent to which the chemical reactions involved are allowed to proceed (mainly controlled by the availability of oxygen and conversion temperature). There are a number of other less common, more experimental or proprietary thermal processes that may offer benefits such as hydrothermal upgrading (HTU) and hydroprocessing. Some have been developed for use on high moisture content biomass,
including aqueous slurries, and allow them to be converted into more convenient forms. Some of the applications of thermal conversion are combined heat and power (CHP) and co-firing. In a typical biomass power plant, efficiencies range from 20-27%.
Chemical conversion A range of chemical processes may be used to convert biomass into other forms, such as to produce a fuel that is more conveniently used, transported or stored, or to exploit some property of the process itself.
Biochemical conversion
A microbial electrolysis cell can be used to directly make hydrogen gas from plant matter As biomass is a natural material, many highly efficient biochemical processes have developed in nature to break down the molecules of which biomass is composed, and many of these biochemical conversion processes can be harnessed. Biochemical conversion makes use of the enzymes of bacteria and other micro-organisms to break down biomass. In most cases micro-organisms are used to perform the conversion process: anaerobic digestion, fermentation and composting. Other chemical processes such as converting straight and waste vegetable oils into biodiesel is transesterification. Another way of breaking down biomass is by breaking down the carbohydrates and simple sugars to make alcohol. However, this process has not been perfected yet. Scientists are still researching the effects of converting biomass.
Environmental impact Using biomass as a fuel produces air pollution in the form of carbon monoxide, NOx (nitrogen oxides), VOCs (volatile organic compounds), particulates and other pollutants, in some cases at levels above those from traditional fuel sources such as coal or natural
gas. Black carbon - a pollutant created by incomplete combustion of fossil fuels, biofuels, and biomass - is possibly the second largest contributor to global warming. In 2009 a Swedish study of the giant brown haze that periodically covers large areas in South Asia determined that it had been principally produced by biomass burning, and to a lesser extent by fossil-fuel burning. Researchers measured a significant concentration of 14C, which is associated with recent plant life rather than with fossil fuels. On combustion, the carbon from biomass is released into the atmosphere as carbon dioxide (CO2). The amount of carbon stored in dry wood is approximately 50% by weight. When from agricultural sources, plant matter used as a fuel can be replaced by planting for new growth. When the biomass is from forests, the time to recapture the carbon stored is generally longer, and the carbon storage capacity of the forest may be reduced overall if destructive forestry techniques are employed. The existing biomass power generating industry in the United States, which consists of approximately 11,000 MW of summer operating capacity actively supplying power to the grid, produces about 1.4 percent of the U.S. electricity supply. Currently, the New Hope Power Partnership is the largest biomass power plant in North America. The 140 MW facility uses sugar cane fiber (bagasse) and recycled urban wood as fuel to generate enough power for its large milling and refining operations as well as to supply renewable electricity for nearly 60,000 homes. The facility reduces dependence on oil by more than one million barrels per year, and by recycling sugar cane and wood waste, preserves landfill space in urban communities in Florida. Biomass power plant size is often driven by biomass availability in close proximity as transport costs of the (bulky) fuel play a key factor in the plant's economics. It has to be noted, however, that rail and especially shipping on waterways can reduce transport costs significantly, which has led to a global biomass market. To make small plants of 1 MWel economically profitable those power plants have need to be equipped with technology that is able to convert biomass to useful electricity with high efficiency such as ORC technology, a cycle similar to the water steam power process just with an organic working medium. Such small power plants can be found in Europe. Despite harvesting, biomass crops may sequester carbon. So for example soil organic carbon has been observed to be greater in switchgrass stands than in cultivated cropland soil, especially at depths below 12 inches. The grass sequesters the carbon in its increased root biomass. Typically, perennial crops sequester much more carbon than annual crops due to much greater non-harvested living biomass, both living and dead, built up over years, and much less soil disruption in cultivation. The biomass-is-carbon-neutral proposal put forward in the early 1990s has been superseded by more recent science that recognizes that mature, intact forests sequester carbon more effectively than cut-over areas. When a tree’s carbon is released into the atmosphere in a single pulse, it contributes to climate change much more than woodland timber rotting slowly over decades. Current studies indicate that "even after 50 years the
forest has not recovered to its initial carbon storage" and "the optimal strategy is likely to be protection of the standing forest".
Chapter-3 Hydroelectricity (First-generation technology)
The Gordon Dam in Tasmania is a large conventional dammed-hydro facility, with an installed capacity of up to 430 MW. Hydroelectricity is the term referring to electricity generated by hydropower; the production of electrical power through the use of the gravitational force of falling or flowing water. It is the most widely used form of renewable energy. Once a hydroelectric complex is constructed, the project produces no direct waste, and has a considerably lower output level of the greenhouse gas carbon dioxide (CO2) than fossil fuel powered energy plants. Worldwide, an installed capacity of 777 GWe supplied 2998 TWh of hydroelectricity in 2006. This was approximately 20% of the world's electricity, and accounted for about 88% of electricity from renewable sources.
History Hydropower has been used since ancient times to grind flour and perform other tasks. In the mid-1770s, a French engineer Bernard Forest de Bélidor published Architecture Hydraulique which described vertical- and horizontal-axis hydraulic machines. By the late 19th century, the electrical generator was developed and could now be coupled with hydraulics. The growing demand for the Industrial Revolution would drive development as well. In 1878, the world's first house to be powered with hydroelectricity was Cragside in Northumberland, England. The old Schoelkopf Power Station No. 1 near Niagara Falls in the U.S. side began to produce electricity in 1881. The first Edison hydroelectric power plant - the Vulcan Street Plant - began operating September 30, 1882, in Appleton, Wisconsin, with an output of about 12.5 kilowatts. By 1886 there was about 45 hydroelectric power plants in the U.S. and Canada. By 1889, there were 200 in the U.S. At the beginning of the 20th century, a large number of small hydroelectric power plants were being constructed by commercial companies in the mountains that surrounded metropolitan areas. By 1920 as 40% of the power produced in the United States was hydroelectric, the Federal Power Act was enacted into law. The Act created the Federal Power Commission who's main purpose was to regulate hydroelectric power plants on federal land and water. As the power plants became larger, their associated dams developed additional purposes to include flood control, irrigation and navigation. Federal funding became necessary for large-scale development and federally owned corporations like the Tennessee Valley Authority (1933) and the Bonneville Power Administration (1937) were created. Additionally, the Bureau of Reclamation which had began a series of western U.S. irrigation projects in the early 20th century was now constructing large hydroelectric projects such as the 1928 Boulder Canyon Project Act. The U.S. Army Corps of Engineers was also involved in hydroelectric development, completing the Bonneville Dam in 1937 and being recognized by the Flood Control Act of 1936 as the premier federal flood control agency. Hydroelectric power plants continued to become larger throughout the 20th century. After the Hoover Dam's initial 1,345 MW power plant became the world's largest hydroelectric power plant in 1936 it was soon eclipsed by the 6809 MW Grand Coulee Dam in 1942. Brazil's and Paraguay's Itaipu Dam opened in 1984 as the largest,
producing 14,000 MW but was surpassed in 2008 by the Three Gorges Dam in China with a production capacity of 22,500 MW. Hydroelectricity would eventually supply countries like Norway, Democratic Republic of the Congo, Paraguay and Brazil with over 85% of their electricity. The United States currently has over 2,000 hydroelectric power plants which supply 49% of its renewable electricity.
Generating methods
Turbine row at Los Nihuiles Power Station in Mendoza, Argentina
Cross section of a conventional hydroelectric dam.
A typical turbine and generator
Conventional Most hydroelectric power comes from the potential energy of dammed water driving a water turbine and generator. The power extracted from the water depends on the volume and on the difference in height between the source and the water's outflow. This height difference is called the head. The amount of potential energy in water is proportional to the head. To deliver water to a turbine while maintaining pressure arising from the head, a large pipe called a penstock may be used.
Pumped-storage This method produces electricity to supply high peak demands by moving water between reservoirs at different elevations. At times of low electrical demand, excess generation capacity is used to pump water into the higher reservoir. When there is higher demand, water is released back into the lower reservoir through a turbine. Pumped-storage schemes currently provide the most commercially important means of large-scale grid energy storage and improve the daily capacity factor of the generation system.
Run-of-the-river Run-of-the-river hydroelectric stations are those with smaller reservoir capacities, thus making it impossible to store water.
Tide A tidal power plant makes use of the daily rise and fall of water due to tides; such sources are highly predictable, and if conditions permit construction of reservoirs, can also be dispatchable to generate power during high demand periods. Less common types of hydro schemes use water's kinetic energy or undammed sources such as undershot waterwheels.
Sizes and capacities of hydroelectric facilities Large and specialized industrial facilities
The Three Gorges Dam, is the largest operating hydroelectric power stations at an installed capacity of 22,500 MW. Although no official definition exist for the capacity range of large hydroelectric power stations, facilities from over a few hundred megawatts to more than 10 GW is generally considered large hydroelectric facilities. Currently, only three facilities over 10 GW (10,000 MW) are in operation worldwide; Three Gorges Dam at 22.5 GW, Itaipu Dam at 14 GW, and Guri Dam at 10.2 GW. Large-scale hydroelectric power stations are more commonly seen as the largest power producing facilities in the world, with some hydroelectric facilities capable of generating more than double the installed capacities of the current largest nuclear power stations. While many hydroelectric projects supply public electricity networks, some are created to serve specific industrial enterprises. Dedicated hydroelectric projects are often built to provide the substantial amounts of electricity needed for aluminium electrolytic plants, for example. The Grand Coulee Dam switched to support Alcoa aluminium in Bellingham, Washington, United States for American World War II airplanes before it was allowed to provide irrigation and power to citizens (in addition to aluminium power) after the war. In Suriname, the Brokopondo Reservoir was constructed to provide electricity for the Alcoa aluminium industry. New Zealand's Manapouri Power Station was constructed to supply electricity to the aluminium smelter at Tiwai Point.
The construction of these large hydroelectric facilities and the changes it makes to the environment, are often too at very large scales, creating just as much damage to the environment as at helps it by being a renewable resource. Many specialized organizations, such as the International Hydropower Association, look into these matters on a global scale.
Small Small hydro is the development of hydroelectric power on a scale serving a small community or industrial plant. The definition of a small hydro project varies but a generating capacity of up to 10 megawatts (MW) is generally accepted as the upper limit of what can be termed small hydro. This may be stretched to 25 MW and 30 MW in Canada and the United States. Small-scale hydroelectricity production grew by 28% during 2008 from 2005, raising the total world small-hydro capacity to 85 GW. Over 70% of this was in China (65 GW), followed by Japan (3.5 GW), the United States (3 GW), and India (2 GW). Small hydro plants may be connected to conventional electrical distribution networks as a source of low-cost renewable energy. Alternatively, small hydro projects may be built in isolated areas that would be uneconomic to serve from a network, or in areas where there is no national electrical distribution network. Since small hydro projects usually have minimal reservoirs and civil construction work, they are seen as having a relatively low environmental impact compared to large hydro. This decreased environmental impact depends strongly on the balance between stream flow and power production.
Micro
A micro-hydro facility in Vietnam. Micro hydro is a term used for hydroelectric power installations that typically produce up to 100 KW of power. These installations can provide power to an isolated home or small community, or are sometimes connected to electric power networks. There are many of these installations around the world, particularly in developing nations as they can provide an economical source of energy without purchase of fuel. Micro hydro systems complement photovoltaic solar energy systems because in many areas, water flow, and thus available hydro power, is highest in the winter when solar energy is at a minimum.
Pico Pico hydro is a term used for hydroelectric power generation of under 5 KW. It is useful in small, remote communities that require only a small amount of electricity. For example, to power one or two fluorescent light bulbs and a TV or radio for a few homes. Even smaller turbines of 200-300W may power a single home in a developing country with a drop of only 1 m (3 ft). Pico-hydro setups typically are run-of-the-river, meaning that dams are not used, but rather pipes divert some of the flow, drop this down a gradient, and through the turbine before being exhausted back to the stream.
Calculating the amount of available power A simple formula for approximating electric power production at a hydroelectric plant is: P = ρhrgk, where • • • • • •
P is Power in watts, ρ is the density of water (~1000 kg/m3), h is height in meters, r is flow rate in cubic meters per second, g is acceleration due to gravity of 9.8 m/s2, k is a coefficient of efficiency ranging from 0 to 1. Efficiency is often higher (that is, closer to 1) with larger and more modern turbines.
Annual electric energy production depends on the available water supply. In some installations the water flow rate can vary by a factor of 10:1 over the course of a year.
Advantages and disadvantages of hydroelectricity Advantages
The Ffestiniog Power Station can generate 360 MW of electricity within 60 seconds of the demand arising.
Economics The major advantage of hydroelectricity is elimination of the cost of fuel. The cost of operating a hydroelectric plant is nearly immune to increases in the cost of fossil fuels such as oil, natural gas or coal, and no imports are needed. Hydroelectric plants also tend to have longer economic lives than fuel-fired generation, with some plants now in service which were built 50 to 100 years ago. Operating labor cost is also usually low, as plants are automated and have few personnel on site during normal operation. Where a dam serves multiple purposes, a hydroelectric plant may be added with relatively low construction cost, providing a useful revenue stream to offset the costs of dam operation. It has been calculated that the sale of electricity from the Three Gorges Dam will cover the construction costs after 5 to 8 years of full generation.
CO2 emissions Since hydroelectric dams do not burn fossil fuels, they do not directly produce carbon dioxide. While some carbon dioxide is produced during manufacture and construction of the project, this is a tiny fraction of the operating emissions of equivalent fossil-fuel electricity generation. One measurement of greenhouse gas related and other externality comparison between energy sources can be found in the ExternE project by the Paul Scherrer Institut and the University of Stuttgart which was funded by the European Commission. According to this project, hydroelectricity produces the least amount of greenhouse gases and externality of any energy source. Coming in second place was wind, third was nuclear energy, and fourth was solar photovoltaic. The extremely positive greenhouse gas impact of hydroelectricity is found especially in temperate climates. The above study was for local energy in Europe; presumably similar conditions prevail in North America and Northern Asia, which all see a regular, natural freeze/thaw cycle (with associated seasonal plant decay and regrowth).
Other uses of the reservoir Reservoirs created by hydroelectric schemes often provide facilities for water sports, and become tourist attractions themselves. In some countries, aquaculture in reservoirs is common. Multi-use dams installed for irrigation support agriculture with a relatively constant water supply. Large hydro dams can control floods, which would otherwise affect people living downstream of the project.
Disadvantages
Ecosystem damage and loss of land
Hydroelectric power stations that uses dams would submerge large areas of land due to the requirement of a reservoir. Large reservoirs required for the operation of hydroelectric power stations result in submersion of extensive areas upstream of the dams, destroying biologically rich and productive lowland and riverine valley forests, marshland and grasslands. The loss of land is often exacerbated by the fact that reservoirs cause habitat fragmentation of surrounding areas. Hydroelectric projects can be disruptive to surrounding aquatic ecosystems both upstream and downstream of the plant site. For instance, studies have shown that dams along the Atlantic and Pacific coasts of North America have reduced salmon populations by preventing access to spawning grounds upstream, even though most dams in salmon habitat have fish ladders installed. Salmon spawn are also harmed on their migration to sea when they must pass through turbines. This has led to some areas transporting smolt downstream by barge during parts of the year. In some cases dams, such as the Marmot Dam, have been demolished due to the high impact on fish. Turbine and power-plant designs that are easier on aquatic life are an active area of research. Mitigation measures
such as fish ladders may be required at new projects or as a condition of re-licensing of existing projects. Generation of hydroelectric power changes the downstream river environment. Water exiting a turbine usually contains very little suspended sediment, which can lead to scouring of river beds and loss of riverbanks. Since turbine gates are often opened intermittently, rapid or even daily fluctuations in river flow are observed. For example, in the Grand Canyon, the daily cyclic flow variation caused by Glen Canyon Dam was found to be contributing to erosion of sand bars. Dissolved oxygen content of the water may change from pre-construction conditions. Depending on the location, water exiting from turbines is typically much warmer than the pre-dam water, which can change aquatic faunal populations, including endangered species, and prevent natural freezing processes from occurring. Some hydroelectric projects also use canals to divert a river at a shallower gradient to increase the head of the scheme. In some cases, the entire river may be diverted leaving a dry riverbed. Examples include the Tekapo and Pukaki Rivers in New Zealand.
Flow shortage Changes in the amount of river flow will correlate with the amount of energy produced by a dam. Lower river flows because of drought, climate change or upstream dams and diversions will reduce the amount of live storage in a reservoir therefore reducing the amount of water that can be used for hydroelectricity. The result of diminished river flow can be power shortages in areas that depend heavily on hydroelectric power.
Methane emissions (from reservoirs)
The Hoover Dam in United States is a large conventional dammed-hydro facility, with an installed capacity of up to 2,080 MW. Lower positive impacts are found in the tropical regions, as it has been noted that the reservoirs of power plants in tropical regions may produce substantial amounts of methane. This is due to plant material in flooded areas decaying in an anaerobic environment, and forming methane, a very potent greenhouse gas. According to the World Commission on Dams report, where the reservoir is large compared to the generating capacity (less than 100 watts per square metre of surface area) and no clearing of the forests in the area was undertaken prior to impoundment of the reservoir, greenhouse gas emissions from the reservoir may be higher than those of a conventional
oil-fired thermal generation plant. Although these emissions represent carbon already in the biosphere, not fossil deposits that had been sequestered from the carbon cycle, there is a greater amount of methane due to anaerobic decay, causing greater damage than would otherwise have occurred had the forest decayed naturally. In boreal reservoirs of Canada and Northern Europe, however, greenhouse gas emissions are typically only 2% to 8% of any kind of conventional fossil-fuel thermal generation. A new class of underwater logging operation that targets drowned forests can mitigate the effect of forest decay. In 2007, International Rivers accused hydropower firms for cheating with fake carbon credits under the Clean Development Mechanism, for hydropower projects already finished or under construction at the moment they applied to join the CDM. These carbon credits – of hydropower projects under the CDM in developing countries – can be sold to companies and governments in rich countries, in order to comply with the Kyoto protocol.
Relocation Another disadvantage of hydroelectric dams is the need to relocate the people living where the reservoirs are planned. In February 2008, it was estimated that 40-80 million people worldwide had been physically displaced as a direct result of dam construction. In many cases, no amount of compensation can replace ancestral and cultural attachments to places that have spiritual value to the displaced population. Additionally, historically and culturally important sites can be flooded and lost. Such problems have arisen at the Aswan Dam in Egypt between 1960 and 1980, the Three Gorges Dam in China, the Clyde Dam in New Zealand, and the Ilisu Dam in Turkey.
Failure hazard Because large conventional dammed-hydro facilities hold back large volumes of water, a failure due to poor construction, terrorism, or other causes can be catastrophic to downriver settlements and infrastructure. Dam failures have been some of the largest man-made disasters in history. Also, good design and construction are not an adequate guarantee of safety. Dams are tempting industrial targets for wartime attack, sabotage and terrorism, such as Operation Chastise in World War II. The Banqiao Dam failure in Southern China directly resulted in the deaths of 26,000 people, and another 145,000 from epidemics. Millions were left homeless. Also, the creation of a dam in a geologically inappropriate location may cause disasters like the one of the Vajont Dam in Italy, where almost 2000 people died, in 1963. Smaller dams and micro hydro facilities create less risk, but can form continuing hazards even after they have been decommissioned. For example, the small Kelly Barnes Dam
failed in 1967, causing 39 deaths with the Toccoa Flood, ten years after its power plant was decommissioned in 1957.
Comparison with other methods of power generation Hydroelectricity eliminates the flue gas emissions from fossil fuel combustion, including pollutants such as sulfur dioxide, nitric oxide, carbon monoxide, dust, and mercury in the coal. Hydroelectricity also avoids the hazards of coal mining and the indirect health effects of coal emissions. Compared to nuclear power, hydroelectricity generates no nuclear waste, has none of the dangers associated with uranium mining, nor nuclear leaks. Unlike uranium, hydroelectricity is also a renewable energy source. Compared to wind farms, hydroelectricity power plants have a more predictable load factor. If the project has a storage reservoir, it can be dispatched to generate power when needed. Hydroelectric plants can be easily regulated to follow variations in power demand. Unlike fossil-fuelled combustion turbines, construction of a hydroelectric plant requires a long lead-time for site studies, hydrological studies, and environmental impact assessment. Hydrological data up to 50 years or more is usually required to determine the best sites and operating regimes for a large hydroelectric plant. Unlike plants operated by fuel, such as fossil or nuclear energy, the number of sites that can be economically developed for hydroelectric production is limited; in many areas the most cost effective sites have already been exploited. New hydro sites tend to be far from population centers and require extensive transmission lines. Hydroelectric generation depends on rainfall in the watershed, and may be significantly reduced in years of low rainfall or snowmelt. Long-term energy yield may be affected by climate change. Utilities that primarily use hydroelectric power may spend additional capital to build extra capacity to ensure sufficient power is available in low water years.
World hydroelectric capacity
World renewable energy share as at 2008, with hydroelectricity more than 50% of all renewable energy sources. The ranking of hydro-electric capacity is either by actual annual energy production or by installed capacity power rating. A hydro-electric plant rarely operates at its full power rating over a full year; the ratio between annual average power and installed capacity rating is the capacity factor. The installed capacity is the sum of all generator nameplate power ratings. Sources came from BP Statistical Review - Full Report 2009 Brazil, Canada, Norway, Paraguay, Switzerland, and Venezuela are the only countries in the world where the majority of the internal electric energy production is from hydroelectric power. Paraguay produces 100% of its electricity from hydroelectric dams, and exports 90% of its production to Brazil and to Argentina. Norway produces 98–99% of its electricity from hydroelectric sources. Ten of the largest hydroelectric producers as at 2009. Annual hydroelectric Installed Capacity % of total Country production (TWh) capacity (GW) factor capacity 652.05 196.79 0.37 22.25 China
Canada 369.5 363.8 Brazil United States 250.6 167.0 Russia 140.5 Norway 115.6 India Venezuela 85.96 69.2 Japan Sweden 65.5
88.974 69.080 79.511 45.000 27.528 33.600 14.622 27.229 16.209
0.59 0.56 0.42 0.42 0.49 0.43 0.67 0.37 0.46
61.12 85.56 5.74 17.64 98.25 15.80 69.20 7.21 44.34
Major projects under construction Name
Xiluodu Dam
Maximum Construction Scheduled Country Capacity started completion 12,600 MW
Siang Upper HE 11,000 Project MW
TaSang Dam
China
December 26, 2015 2005
India
April, 2009
7,110 MW Burma
Xiangjiaba Dam 6,400 MW China Nuozhadu Dam 5,850 MW China
Jinping 2 Hydropower Station
Jinping 1 Hydropower Station Pubugou Dam
2024
March, 2007 2022
Comments Construction once stopped due to lack of environmental impact study. Multi-phase construction over a period of 15 years. Construction was delayed due to dispute with China. Controversial 228 meter tall dam with capacity to produce 35,446 Ghw annually.
November 26, 2015 2006 2006 2017
4,800 MW China
January 30, 2007
3,600 MW China
November 11, 2014 2005
3,300 MW China
March 30,
2014
2010
To build this dam, 23 families and 129 local residents need to be moved. It works with Jinping 1 Hydropower Station as a group.
Goupitan Dam Guanyinyan Dam
3,000 MW China 3,000 MW China
2004 November 8, 2011 2003 2008
2015
Construction of the roads and spillway started.
Lianghekou 3,000 MW China 2009 2015 Dam Boguchan Dam 3,000 MW Russia 1980 2010 Chapetón 3,000 MW Argentina August 15, Dagangshan 2,600 MW China 2014 2008 December Jinanqiao Dam 2,400 MW China 2010 2006 November 11, Guandi Dam 2,400 MW China 2012 2007 Liyuan Dam 2,400 MW China 2008
Tocoma Dam Bolívar State
2,160 MW Venezuela 2004
2014
Ludila Dam
2,100 MW China
2015
Shuangjiangkou 2,000 MW China Dam Ahai Dam 2,000 MW China Subansiri Lower 2,000 MW India Dam
2007 December, 2007 July 27, 2006 2005
2012
This new power plant would be the last development in the Low Caroni Basin, bringing the total to six power plants on the same river, including the 10,000MW Guri Dam. Construction halt due to lack of the evnironmental assessment. The dam will be 314 m high.
Chapter-4 Geothermal Electricity (First-generation Technology)
Geothermal electricity is electricity generated from geothermal energy. Technologies in use include dry steam power plants, flash steam power plants and binary cycle power plants. As a more recent technology, geothermal electricity generation is currently used only in 24 countries while geothermal heating is in use in 70 countries. Estimates of the electricity generating potential of geothermal energy vary from 35 to 2000 GW. Current worldwide installed capacity is 10,715 megawatts (MW), with the largest capacity in the United States (3,086 MW), Philippines, and Indonesia. Geothermal power is considered to be sustainable because the heat extraction is small compared to the Earth's heat content. The emission intensity of existing geothermal electric plants is on average 122 kg of CO2 per megawatt-hour (MW·h) of electricity, a small fraction of that of conventional fossil fuel plants.
History and development
Global geothermal electric capacity. Upper red line is installed capacity; lower green line is realized production. In the 20th century, demand for electricity led to the consideration of geothermal power as a generating source. Prince Piero Ginori Conti tested the first geothermal power generator on 4 July 1904 in Larderello, Italy. It successfully lit four light bulbs. Later, in 1911, the world's first commercial geothermal power plant was built there. Experimental generators were built in Beppu, Japan and the Geysers, California, in the 1920s, but Italy was the world's only industrial producer of geothermal electricity until New Zealand built a plant in 1958. In 1960, Pacific Gas and Electric began operation of the first successful geothermal electric power plant in the United States at The Geysers in California. The original turbine lasted for more than 30 years and produced 11 MW net power. The binary cycle power plant was first demonstrated in 1967 in Russia and later introduced to the USA in 1981. This technology allows the use of much lower temperature resources than were previously recoverable. In 2006, a binary cycle plant in Chena Hot Springs, Alaska, came on-line, producing electricity from a record low fluid temperature of 57°C. Geothermal electric plants have until recently been built exclusively where high temperature geothermal resources are available near the surface. The development of binary cycle power plants and improvements in drilling and extraction technology may
enable enhanced geothermal systems over a much greater geographical range. Demonstration projects are operational in Landau-Pfalz, Germany, and Soultz-sousForêts, France, while an earlier effort in Basel, Switzerland was shut down after it triggered earthquakes. Other demonstration projects are under construction in Australia, the United Kingdom, and the United States of America. The thermal efficiency of geothermal electric plants is low, around 10-23%, because geothermal fluids are at a low temperature compared to steam from boilers. By the laws of thermodynamics this low temperature limits the efficiency of heat engines in extracting useful energy during the generation of electricity. Exhaust heat is wasted, unless it can be used directly and locally, for example in greenhouses, timber mills, and district heating. The efficiency of the system does not affect operational costs as it would for a coal or other fossil fuel plant, but it does factor into the viability of the plant. In order to produce more energy than the pumps consume, electricity generation requires high temperature geothermal fields and specialized heat cycles. Because geothermal power does not rely on variable sources of energy, unlike, for example, wind or solar, its capacity factor can be quite large – up to 96% has been demonstrated. The global average was 73% in 2005.
Resources
Enhanced geothermal system 1:Reservoir 2:Pump house 3:Heat exchanger 4:Turbine hall 5:Production well 6:Injection well 7:Hot water to district heating 8:Porous sediments 9:Observation well 10:Crystalline bedrock The earth’s heat content is 1031 joules. This heat naturally flows to the surface by conduction at a rate of 44.2 terawatts, (TW,) and is replenished by radioactive decay at a rate of 30 TW. These power rates are more than double humanity’s current energy consumption from primary sources, but most of this power is too diffuse (approximately 0.1 W/m2 on average) to be recoverable. The Earth's crust effectively acts as a thick insulating blanket which must be pierced by fluid conduits (of magma, water or other) to release the heat underneath.
Electricity generation requires high temperature resources that can only come from deep underground. The heat must be carried to the surface by fluid circulation, either through magma conduits, hot springs, hydrothermal circulation, oil wells, drilled water wells, or a combination of these. This circulation sometimes exists naturally where the crust is thin: magma conduits bring heat close to the surface, and hot springs bring the heat to the surface. If no hot spring is available, a well must be drilled into a hot aquifer. Away from tectonic plate boundaries the geothermal gradient is 25-30°C per kilometre (km) of depth in most of the world, and wells would have to be several kilometres deep to permit electricity generation. The quantity and quality of recoverable resources improves with drilling depth and proximity to tectonic plate boundaries. In ground that is hot but dry, or where water pressure is inadequate, injected fluid can stimulate production. Developers bore two holes into a candidate site, and fracture the rock between them with explosives or high pressure water. Then they pump water or liquefied carbon dioxide down one borehole, and it comes up the other borehole as a gas. This approach is called hot dry rock geothermal energy in Europe, or enhanced geothermal systems in North America. Much greater potential may be available from this approach than from conventional tapping of natural aquifers. Estimates of the electricity generating potential of geothermal energy vary from 35 to 2000 GW depending on the scale of investments. This does not include non-electric heat recovered by co-generation, geothermal heat pumps and other direct use. A 2006 report by the Massachusetts Institute of Technology (MIT), that included the potential of enhanced geothermal systems, estimated that investing 1 billion US dollars in research and development over 15 years would allow the creation of 100 GW of electrical generating capacity by 2050 in the United States alone. The MIT report estimated that over 200 zettajoules (ZJ) would be extractable, with the potential to increase this to over 2,000 ZJ with technology improvements - sufficient to provide all the world's present energy needs for several millennia. At present, geothermal wells are rarely more than 3 kilometres (2 mi) deep. Upper estimates of geothermal resources assume wells as deep as 10 kilometres (6 mi). Drilling at this depth is now possible in the petroleum industry, although it is an expensive process. The deepest research well in the world, the Kola superdeep borehole, is 12 kilometres (7 mi) deep. This record has recently been imitated by commercial oil wells, such as Exxon's Z-12 well in the Chayvo field, Sakhalin. Wells drilled to depths greater than 4 kilometres (2 mi) generally incur drilling costs in the tens of millions of dollars. The technological challenges are to drill wide bores at low cost and to break larger volumes of rock. Geothermal power is considered to be sustainable because the heat extraction is small compared to the Earth's heat content, but extraction must still be monitored to avoid local depletion. Although geothermal sites are capable of providing heat for many decades, individual wells may cool down or run out of water. The three oldest sites, at Larderello, Wairakei, and the Geysers have all reduced production from their peaks. It is not clear whether these plants extracted energy faster than it was replenished from greater depths,
or whether the aquifers supplying them are being depleted. If production is reduced, and water is reinjected, these wells could theoretically recover their full potential. Such mitigation strategies have already been implemented at some sites. The long-term sustainability of geothermal energy has been demonstrated at the Lardarello field in Italy since 1913, at the Wairakei field in New Zealand since 1958, and at The Geysers field in California since 1960.
Power station types
Dry steam plant
Flash steam plant
Dry steam power plants Dry steam plants are the simplest and oldest design. They directly use geothermal steam of 150°C or more to turn turbines.
Flash steam power plants Flash steam plants pull deep, high-pressure hot water into lower-pressure tanks and use the resulting flashed steam to drive turbines. They require fluid temperatures of at least 180°C, usually more. This is the most common type of plant in operation today.
Binary cycle power plants Binary cycle power plants are the most recent development, and can accept fluid temperatures as low as 57°C. The moderately hot geothermal water is passed by a secondary fluid with a much lower boiling point than water. This causes the secondary fluid to flash to vapor, which then drives the turbines. This is the most common type of geothermal electricity plant being built today. Both Organic Rankine and Kalina cycles are used. The thermal efficiency is typically about 10%.
Worldwide production The International Geothermal Association (IGA) has reported that 10,715 megawatts (MW) of geothermal power in 24 countries is online, which is expected to generate 67,246 GWh of electricity in 2010. This represents a 20% increase in geothermal power online capacity since 2005. IGA projects this will grow to 18,500 MW by 2015, due to the large number of projects presently under consideration, often in areas previously assumed to have little exploitable resource. In 2010, the United States led the world in geothermal electricity production with 3,086 MW of installed capacity from 77 power plants; the largest group of geothermal power plants in the world is located at The Geysers, a geothermal field in California. The Philippines follows the US as the second highest producer of geothermal power in the world, with 1,904 MW of capacity online; geothermal power makes up approximately 18% of the country's electricity generation.
Utility-grade plants The largest group of geothermal power plants in the world is located at The Geysers, a geothermal field in California, United States. As of 2004, five countries (El Salvador, Kenya, the Philippines, Iceland, and Costa Rica) generate more than 15% of their electricity from geothermal sources. Naknek Electric Association (NEA) is going to make an exploration well near King Salmon, in Southwest Alaska. It could cut the cost of electricity production by 71 percent and the planned power is 25 megawatts. Geothermal electricity is generated in the 24 countries listed in the table below. During 2005, contracts were placed for an additional 500 MW of electrical capacity in the United States, while there were also plants under construction in 11 other countries. Enhanced geothermal systems that are several kilometres in depth are operational in France and Germany and are being developed or evaluated in at least four other countries. Installed geothermal electric capacity Country
percentage Capacity (MW) Capacity (MW) of national 2007 2010 production
USA 2687 Philippines 1969.7 Indonesia 992 Mexico 953 Italy 810.5 New Zealand 471.6 Iceland 421.2 Japan 535.2 El Salvador 204.2 Kenya 128.8 Costa Rica 162.5 Nicaragua 87.4 Russia 79 Turkey 38 Papua-New Guinea 56 Guatemala 53 Portugal 23 China 27.8 France 14.7 Ethiopia 7.3 Germany 8.4 Austria 1.1 Australia 0.2 Thailand 0.3 TOTAL 9,731.9
3086 1904 1197 958 843 628 575 536 204 167 166 88 82 82 56 52 29 24 16 7.3 6.6 1.4 1.1 0.3 10,709.7
0.3% 27% 3.7% 3% 10% 30% 0.1% 14% 11.2% 14% 10%
Environmental impact
Krafla Geothermal Station in northeast Iceland Fluids drawn from the deep earth carry a mixture of gases, notably carbon dioxide (CO2), hydrogen sulfide (H2S), methane (CH4) and ammonia (NH3). These pollutants contribute to global warming, acid rain, and noxious smells if released. Existing geothermal electric plants emit an average of 122 kg of CO2 per megawatt-hour (MW·h) of electricity, a small fraction of the emission intensity of conventional fossil fuel plants. Plants that experience high levels of acids and volatile chemicals are usually equipped with emission-control systems to reduce the exhaust. Geothermal plants could theoretically inject these gases back into the earth, as a form of carbon capture and storage. In addition to dissolved gases, hot water from geothermal sources may hold in solution trace amounts of toxic chemicals such as mercury, arsenic, boron, antimony, and salt. These chemicals come out of solution as the water cools, and can cause environmental damage if released. The modern practice of injecting geothermal fluids back into the Earth to stimulate production has the side benefit of reducing this environmental risk. Plant construction can adversely affect land stability. Subsidence has occurred in the Wairakei field in New Zealand. Enhanced geothermal systems can trigger earthquakes as part of hydraulic fracturing. The project in Basel, Switzerland was suspended because
more than 10,000 seismic events measuring up to 3.4 on the Richter Scale occurred over the first 6 days of water injection. Geothermal has minimal land and freshwater requirements. Geothermal plants use 3.5 square kilometres per gigawatt of electrical production (not capacity) versus 32 and 12 square kilometres for coal facilities and wind farms respectively. They use 20 litres of freshwater per MW·h versus over 1000 litres per MW·h for nuclear, coal, or oil.
Economics Geothermal power requires no fuel, and is therefore immune to fuel cost fluctuations, but capital costs tend to be high. Drilling accounts for over half the costs, and exploration of deep resources entails significant risks. A typical well doublet in Nevada can support 4.5 megawatt (MW) of electricity generation and costs about $10 million to drill, with a 20% failure rate. In total, electrical plant construction and well drilling cost about 2-5 million € per MW of electrical capacity, while the levelised energy cost is 0.04-0.10 € per kW·h. Enhanced geothermal systems tend to be on the high side of these ranges, with capital costs above $4 million per MW and levelized costs above $0.054 per kW·h in 2007. Geothermal power is highly scalable: a large geothermal plant can power entire cities while a smaller power plant can supply a rural village. Chevron Corporation is the world's largest private producer of geothermal electricity. The most developed geothermal field is the Geysers in California. In 2008, this field supported 15 plants, all owned by Calpine, with a total generating capacity of 725 MW.
Chapter-5 Solar Water Heating (Second-generation technology)
Roof-mounted close-coupled thermosiphon solar water heater. Solar water heating (SWH) systems comprise several innovations and many mature renewable energy technologies which have been accepted in most countries for many years. SWH has been widely used in Israel, Australia, Japan, Austria and China and co.
In a "close-coupled" SWH system the storage tank is horizontally mounted immediately above the solar collectors on the roof. No pumping is required as the hot water naturally rises into the tank through thermosiphon flow. In a "pump-circulated" system the storage tank is ground or floor mounted and is below the level of the collectors; a circulating pump moves water or heat transfer fluid between the tank and the collectors. SWH systems are designed to deliver the optimum amount of hot water for most of the year. However, in winter there sometimes may not be sufficient solar heat gain to deliver sufficient hot water. In this case a gas or electric booster is normally used to heat the water.
Overview Hot water heated by the sun is used in many ways. While perhaps best known in a residential setting to provide hot domestic water, solar hot water also has industrial applications, e.g. to generate electricity . Designs suitable for hot climates can be much simpler and cheaper, and can be considered an appropriate technology for these places. The global solar thermal market is dominated by China, Europe, Japan and India.
A solar hot water heater installed on a house in Belgium In order to heat water using solar energy, a collector, often fastened to a roof or a wall facing the sun, heats working fluid that is either pumped (active system) or driven by natural convection (passive system) through it. The collector could be made of a simple glass topped insulated box with a flat solar absorber made of sheet metal attached to copper pipes and painted black, or a set of metal tubes surrounded by an evacuated (near
vacuum) glass cylinder. In industrial cases a parabolic mirror can concentrate sunlight on the tube. Heat is stored in a hot water storage tank. The volume of this tank needs to be larger with solar heating systems in order to allow for bad weather, and because the optimum final temperature for the solar collector is lower than a typical immersion or combustion heater. The heat transfer fluid (HTF) for the absorber may be the hot water from the tank, but more commonly (at least in active systems) is a separate loop of fluid containing anti-freeze and a corrosion inhibitor which delivers heat to the tank through a heat exchanger (commonly a coil of copper tubing within the tank). Another lowermaintenance concept is the 'drain-back': no anti-freeze is required; instead all the piping is sloped to cause water to drain back to the tank. The tank is not pressurized and is open to atmospheric pressure. As soon as the pump shuts off, flow reverses and the pipes are empty before freezing could occur. Residential solar thermal installations fall into two groups: passive (sometimes called "compact") and active (sometimes called "pumped") systems. Both typically include an auxiliary energy source (electric heating element or connection to a gas or fuel oil central heating system) that is activated when the water in the tank falls below a minimum temperature setting such as 55°C. Hence, hot water is always available. The combination of solar water heating and using the back-up heat from a wood stove chimney to heat water can enable a hot water system to work all year round in cooler climates, without the supplemental heat requirement of a solar water heating system being met with fossil fuels or electricity. When a solar water heating and hot-water central heating system are used in conjunction, solar heat will either be concentrated in a pre-heating tank that feeds into the tank heated by the central heating, or the solar heat exchanger will replace the lower heating element and the upper element will remain in place to provide for any heating that solar cannot provide. However, the primary need for central heating is at night and in winter when solar gain is lower. Therefore, solar water heating for washing and bathing is often a better application than central heating because supply and demand are better matched.In many climates, a solar hot water system can provide up to 85% of domestic hot water energy. This can include domestic non-electric concentrating solar thermal systems. In many northern European countries, combined hot water and space heating systems (solar combisystems) are used to provide 15 to 25% of home heating energy.
History There are records of solar collectors in the United States dating back to before 1900, comprising a black-painted tank mounted on a roof. In 1896 Clarence Kemp of Baltimore, USA enclosed a tank in a wooden box, thus creating the first 'batch water heater' as they are known today. Although flat-plate collectors for solar water heating were used in Florida and Southern California in the 1920s there was a surge of interest in solar heating in North America after 1960, but specially after the 1973 oil crisis.
Work in Israel
Passive (thermisiphon) solar water heaters on a rooftop in Jerusalem Flat plate solar systems were perfected and used on a very large scale in Israel. In the 1950s there was a fuel shortage in the new Israeli state, and the government forbade heating water between 10 p.m. and 6 a.m.. Levi Yissar built the first prototype Israeli solar water heater and in 1953 he launched the NerYah Company, Israel's first commercial manufacturer of solar water heating. Despite the abundance of sunlight in Israel, solar water heaters were used by only 20% of the population by 1967. Following the energy crisis in the 1970s, in 1980 the Israeli Knesset passed a law requiring the installation of solar water heaters in all new homes (except high towers with insufficient roof area). As a result, Israel is now the world leader in the use of solar energy per capita with 85% of the households today using solar thermal systems (3% of the primary
national energy consumption), estimated to save the country two million barrels of oil a year, the highest per capita use of solar energy in the world..
Other countries
New solar hot water installations during 2007, worldwide. The world saw a rapid growth of the use of solar warm water after 1960, with systems being marketed also in Japan and Australia Technical innovation has improved performance, life expectancy and ease of use of these systems. Installation of solar water heating has become the norm in countries with an abundance of solar radiation, like the Mediterranean, and Japan and Austria, where there Colombia developed a local solar water heating industry thanks to the designs of Las Gaviotas, directed by Paolo Lugari. Driven by a desire to reduce costs in social housing, the team of Gaviotas studied the best systems from Israel, and made adaptations as to meet the specifications set by the Banco Central Hipotecario (BCH) which prescribed that the system must be operational in cities like Bogotá where there are more than 200 days overcast. The ultimate designs were so successful that Las Gaviotas offered in 1984 a 25 year warranty on any of its installations. Over 40,000 were installed, and still function a quarter of a century later. In 2005, Spain became the first country in the world to require the installation of photovoltaic electricity generation in new buildings, and the second (after Israel) to require the installation of solar water heating systems in 2006.
Australia has a variety of incentives (national and state) and regulations (state) for solar thermal introduced starting with MRET in 1997 . Solar water heating systems have become popular in China, where basic models start at around 1,500 yuan (US$190), much cheaper than in Western countries (around 80% cheaper for a given size of collector). It is said that at least 30 million Chinese households now have one, and that the popularity is due to the efficient evacuated tubes which allow the heaters to function even under gray skies and at temperatures well below freezing . Israel and Cyprus are the per capita leaders in the use of solar water heating systems with over 30%-40% of homes using them.
Types of Solar Water Heating (SWH) systems
A monobloc (thermosiphon) solar heater in Cirque de Mafate, La Réunion The type and complexity of a solar water heating system is mostly determined by: • • •
The changes in ambient temperature during the day-night cycle. Changes in ambient temperature and solar radiation between summer and winter. The temperature of the water required from the system.
The minimum efficiency of the system is determined by the amount or temperature of hot water required during winter (when the largest amount of hot water is often required). The maximum efficiency of the system is determined by the need to prevent the water in the system from becoming too hot (to boil, in an extreme case). There are two main categories of solar water heating systems. Passive systems rely on convection or heat pipes to circulate water or heating fluid in the system, while active systems use a pump. In addition, there are a number of other system characteristics that distinguish different designs: • • • • •
The type of collector used (see below) The location of the collector - roof mount, ground mount, wall mount The location of the storage tank in relation to the collector The method of heat transfer - open-loop or closed-loop (via heat exchanger) Photovoltaic thermal hybrid solar collectors can be designed to produce both hot water and electricity.
Passive systems
An integrated collector storage (ICS) system A special type of passive system is the Integrated Collector Storage (ICS or Batch Heater) where the tank acts as both storage and solar collector. Batch heaters are basically thin rectilinear tanks with glass in front of it generally in or on house wall or roof. They are seldom pressurised and usually depend on gravity flow to deliver their water. They are simple, efficient and less costly than plate and tube collectors but are only suitable in moderate climates with good sunshine. A step up from the ICS is the Convection Heat Storage unit (CHS or thermosiphon). These are often plate type or evacuated tube collectors with built-in insulated tanks. The unit uses convection (movement of hot water upward) to move the water from collector to tank. Neither pumps nor electricity are used to enforce circulation. It is more efficient
than an ICS as the collector heats a small(er) amount of water that constantly rises back to the tank. It can be used in areas with less sunshine than the ICS. An CHS also known as a compact system or monobloc has a tank for the heated water and a solar collector mounted on the same chassis. Typically these systems will function by natural convection or heat pipes to transfer the heat energy from the collector to the tank.
Direct systems: (A) Passive CHS system with tank above collector. (B) Active system with pump and controller driven by a photovoltaic panel Direct ('open loop') passive systems use water from the main household water supply to circulate between the collector and the storage tank. When the water in the collector becomes warm, convection causes it to rise and flow towards the water storage tank. They are often not suitable for cold climates since, at night, the water in the collector can freeze and damage the panels. Indirect ('closed loop') passive systems use a non-toxic antifreeze heat transfer fluid (HTF) in the collector. When this fluid is heated, convection causes it to flow to the tank where a passive heat exchanger transfers the heat of the HTF to the water in the tank. The attraction of passive solar water heating systems lies in their simplicity. There are no mechanical or electrical parts that can break or that require regular supervision or maintenance. Consequently the maintenance of a passive system is simple and cheap. The efficiency of a passive system is often somewhat lower than that of an active system and overheating is largely avoided by the inherent design of a passive system.
Active systems
Indirect active systems: (C) Indirect system with heat exchanger in tank; (D) Drainback system with drainback reservoir. In these schematics the controller and pump are driven by mains electricity Active solar hot water systems employ a pump to circulate water or HTF between the collector and the storage tank. Like their passive counterparts, active solar water heating systems come as two types: direct active systems pump water directly to the collector and back to the storage tank (direct collectors can contain conventional freeze-vulnerable metal pipes or low pressure freeze-tolerant silicone rubber pipes), indirect active systems which are usually made of metals pump heat transfer fluid (HTF), the heat of which is transferred to the water in the storage tank. Because the pump should only operate when the fluid in the collector is hotter than the water in the storage tank, a controller is
required to turn the pump on and off. The use of an electronically controlled pump has several advantages: •
The storage tank can be situated lower than the collectors. In passive systems the storage tank must be located above the collector so that the thermosiphon effect can transport water or HTF from collector to tank. The use of a pump allows the storage tank to be located lower than the collector since the circulation of water or HTF is enforced by the pump. A pumped system allows the storage tank to be located out of sight.
•
Because of the fact that active systems allow freedom in the location of the storage tank, the tank can be located where heat loss from the tank is reduced, e.g. inside the roof of a house. This increases the efficiency of the solar water heating system.
•
New active solar water heating systems can make use of an existing warm water storage tanks ("geysers"), thus avoiding duplication of equipment.
•
Reducing the risk of overheating. If no water from the solar hot water system is used (e.g. when water users are away), the water in the storage tank is likely to overheat. Several pump controllers avoid overheating by activating the pump during the day at during times of low sunlight, or at night. This pumps hot water or HTF from the storage tank through the collector (which can be cool in low light levels), thus cooling the water in the storage tank.
•
Reducing the risk of freezing. For direct active systems in cold weather, where freeze tolerant collectors or drain down approaches are not used, the pump controller can pump hot water from the water storage tank through the collector in order to prevent the water in the collector from freezing, thus avoiding damage to the metal parts of the system.
Active systems can tolerate higher water temperatures than would be the case in an equivalent passive system. Consequently active systems are often more efficient than passive systems but are more complex, more expensive, more difficult to install and rely on either mains or PV sourced electricity to run the pump and controller.
Active systems with intelligent controllers Modern active solar water systems have electronic controllers that permit a wide range of functionality such as full programmability; interaction with a backup electric or gasdriven water heater; measurement of the energy produced; sophisticated safety functions; thermostatic and time-clock control of auxiliary heat, hot water circulation loops, or others; display of error messages or alarms; remote display panels; and remote or local datalogging.
A typical programmable differential controller The most popular pump controller is a differential controller that senses temperature differences between water leaving the solar collector and the water in the storage tank near the heat exchanger. In a typical indirect configuration, the controller turns the pump on when the water in the collector is about 8-10°C warmer than the water in the tank and it turns the pump off when the temperature difference approaches 0 °C. This ensures the water always gains heat from the collector when the pump operates and prevents the pump from cycling on and off too often. In direct systems this "on differential" can be reduced to around 4C because there is no heat exchanger impediment. By allowing more "pump on" time, this improves performance at low light levels. Although the pumps of most active systems are driven by mains electricity, some active solar systems obtain energy to power the pump by a photovoltaic (PV) panel. The PV panel converts sunlight into electricity, which in turn drives the direct current (DC) pump. In this way, water flows through the collector only when the sun is shining. The DC-pump and PV panel must be suitably matched to ensure proper performance. The pump starts when there is sufficient solar radiation available to heat the solar collector and to start the pump. This "pump starting" irradiation varies from 4% to 10% of full sunlight, depending on the pump and its PV power supply. It shuts off later in the day when the available solar energy diminishes. Several DC-pumps are intelligent and employ maximum power point (MPP) tracking to optimise pump rate, for instance during periods of small amounts of electricity from the PV panel during cloudy weather. A PV powered solar controller is sometimes used to prevent the pump from running when there is sunlight to power the pump but the collector is still cooler than the water in storage. The main environmental advantage of a PV-driven pump is that it eliminates the energy / carbon clawback or "parasitics" associated with using a solar thermal systems. Also the solar hot water can still be collected during a power outage. The pump is operated by the sun and is completely independent from mains electricity. Some differential controllers use power from the PV panel when sunlight is available, but revert to mains electricity when light is not available.
The low /variable flow from PV powered pumps for domestic hot water only (no heating) is typically matched with a temperature maximising solar absorber of the serpentine type. This in conjunction with a stratified hot water tank design maximises a small quantity of hot water that reduces the need for the standby heating system to operate. This stategy has been found to maximise efficiency.
Active systems with drainback A drain-back system is an indirect active system where heat transfer fluid circulates through the collector, being driven by a pump. However the collector piping is not pressurised and includes an open drainback reservoir. If the pump is switched off, all the heat transfer fluid drains into the drainback reservoir and none remains in the collector. Consequently the collector cannot be damaged by freezing or overheating. This makes this type of system well-suited to colder climates.
Active systems with a bubble pump
The bubble separator of a bubble-pump system An active solar water heating system can be equipped with a bubble pump (also known as geyser pump) instead of an electric pump. A bubble pump circulates the heat transfer fluid (HTF) between collector and storage tank using solar power and without any external energy source and is suitable for flat panel as well as vacuum tube systems. In a bubble pump system, the closed HTF circuit is under reduced pressure, which causes the liquid to boil at low temperature as it is heated by the sun. The steam bubbles form a geyser pump, causing an upward flow. The system is designed such that the bubbles are separated from the hot fluid and condensed at the highest point in the circuit, after which the fluid flows downward towards the heat exchanger caused by the difference in fluid levels. The HTF typically arrives at the heat exchanger at 70 °C and returns to the circulating pump at 50 °C. In frost prone climates the HTF is water with propylene glycol anti-freeze added, usually in the ratio of 60 to 40. Pumping typically starts at about 50°C and increases as the sun rises until equilibrium is reached depending on the efficiency of the heat exchanger, the temperature of the water being heated and the strength of the sun.
Freeze protection Freeze protection measures prevent damage to the system due to the expansion of freezing transfer fluid. Some systems drain the transfer fluid from the system when the pump stops. In indirect systems (where the transfer fluid is separated from the heated water), this is called drainback and in direct systems (where the heated water is used as the transfer fluid) it is called draindown. Many indirect systems use anti-freeze (e.g. propylene glycol) in the heat transfer fluid. This approach is simpler and more reliable than drainback and is common in climates where freezing temperatures occur often. In both direct and indirect systems, automatic recirculation may be used for freeze protection. When the water in the collector reaches a temperature near freezing, the controller turns the pump on for a few minutes to warm the collector with water from the tank. In some direct systems, the collectors are manually drained when freezing is expected. This approach is common in climates where freezing temperatures do not occur often. Other direct systems use freeze tolerant solar collectors. Here the water channels of the collector are made of flexible polymers such as silicone rubber. Being non-metal, these can freeze solid without cracking. One European solar collector is being produced to this specification under the Solar Keymark and EN 12975 standards.
Overheat protection Particularly when no hot water has been used for some time, the water from the collector can reach very high temperatures in good sunshine, or if the pump fails to operate, such as during a power cut. Designs which may boil the hot water store usually allow for relief of pressure and excess heat through a heat dump. Almost all sealed and unvented solar circuits have pressure relief valves through which excessive water pressure or steam can be vented. Vented systems have a simpler safety feature already built in via the open vent, a simple and virtually fail-safe approach. Some active systems deliberately cool the water in the storage tank by heat export: circulating hot water through the collector at times when there is little sunlight or at night (when solar energy does not heat the collector). Heat export operates most effectively in systems which do not use basal heat exchangers to add heat to the water store (because cool water sinks below hot water). 11 possible types of overheat control in solar thermal have been identified in the International Energy Agency's Task Group 39 on Polymeric materials in solar heating and cooling.
A rough comparison of solar hot water systems Characteristic
Comparison of SWH systems ICS Active Active Bubble Thermosyphon Drainback (Batch) direct indirect Pump
Low profileunobtrusive Lightweight collector Survives freezing weather Low maintenance Simple: no ancillary control Retrofit potential to existing store Space saving: no extra storage tank
Collectors used in modern domestic solar water heating systems Solar thermal collectors capture and retain heat from the sun and transfer this heat to a liquid. Two important physical principles govern the technology of solar thermal collectors: •
•
Any hot object ultimately returns to thermal equilibrium with its environment, due to heat loss from the hot object. The processes that result in this heat loss are conduction, convection and radiation. The efficiency of a solar thermal collector is directly related to heat losses from the collector surface (efficiency being defined as the proportion of heat energy that can be retained for a predefined period of time). Within the context of a solar collector, convection and radiation are the most important sources of heat loss. Thermal insulation is used to slow down heat loss from a hot object to its environment. This is actually a direct manifestation of the Second law of thermodynamics but we may term this the 'equilibrium effect'. Heat is lost more rapidly if the temperature difference between a hot object and its environment is larger. Heat loss is predominantly governed by the thermal gradient between the temperature of the collector surface and the ambient temperature. Conduction, convection as well as radiation occur more rapidly over large thermal gradients. We may term this the 'delta-t effect'.
The most simple approach to solar heating of water is to simply mount a metal tank filled with water in a sunny place. The heat from the sun would then heat the metal tank and the water inside. Indeed, this was how the very first SWH systems worked more than a century ago. However, this setup would be inefficient due to an oversight of the equilibrium effect, above: once when the tank and water has started to be heated, the heat gained would be lost back into the environment, ultimately until the water in the tank would assume the ambient temperature. The challenge is therefore to limit the heat loss from the tank, thus delaying the time until thermal equilibrium is reached.
ICS or batch collectors overcome the above problem by putting the water tank in a box that limits the loss of heat from the tank back into the environment. This is achieved by encasing the water tank in a glass-topped box that allows heat from the sun to reach the water tank. However, the other walls of the box are thermally insulated, reducing convection as well as radiation to the environment. In addition, the box can also have a reflective surface on the inside. This reflects heat lost from the tank back towards the tank. In a simple way one could consider an ICS solar water heater as a water tank that has been enclosed in a type of 'oven' that retains heat from the sun as well as heat of the water in the tank. Using a box does not eliminate heat loss from the tank to the environment, but it largely reduces this loss. There are many variations on this basic design, with some ICS collectors comprising several smaller water containers and even including evacuated glass tube technology. This is because ICS collectors have a characteristic that strongly limits the efficiency of the collector: a small surface-tovolume ratio. Since the amount of heat that a tank can absorb from the sun is largely dependent on the surface of the tank directly exposed to the sun, it follows that a small surface would limit the degree to which the water can be heated by the sun. Cylindrical objects such as the tank in an ICS collector inherently have a small surface-to-volume ratio and most modern collectors attempt to increase this ratio for efficient warming of the water in the tank.
Flat plate and evacuated tube collectors side-by-side. Flat plate collectors are an extension of the basic idea to place a collector in an 'oven'like box. Here, a pipe is connected to the water tank and the water is circulated through this pipe and back into the tank. The water tank is now outside the collector that only contains the pipes. Since the surface-to-volume ratio increases sharply as the diameter of a pipe decreases, most flat-plate collectors have pipes less than 1 cm in diameter. The efficiency of the heating process is therefore sharply increased. The design of a flat-plate collector therefore typically takes the shape of a flat box with a robust glass top oriented towards the sun, enclosing a network of piping. In many flat-plate collectors the metal
surface of the pipe is increased with flat metal flanges or even a large, flat metal plate to which the pipes are connected. Since the water in a flat-plate collector usually reaches temperatures much higher than that of an ICS, the problem of radiation of heat back to the environment is very important, even though a box-like 'oven' is used. This is because the 'delta-t effect' is becoming important. Formed collectors are a degenerate modification of a flat-plate collector in that the piping of the collector is not enclosed in a box-like 'oven'. Consequently these types of collectors are much less efficient for domestic water heating. However, since water colder than the ambient temperature is heated, these collectors are efficient for that specific purpose. Evacuated tube collectors are a way in which heat loss to the environment, inherent in flat plates, has been reduced. Since heat loss due to convection cannot cross a vacuum, it forms an efficient isolation mechanism to keep heat inside the collector pipes. Since two flat sheets of glass are normally not strong enough to withstand a vacuum, the vacuum is rather created between two concentric tubes. Typically, the water piping in an evacuated tube collector is therefore surrounded by two concentric tubes of glass with a vacuum in between that admits heat from the sun (to heat the pipe) but which limits heat loss back to the environment. The inner tube is coated with a thermal absorbent. Flat plate collectors are generally more efficient than evacuated tube collectors in full sunshine conditions. However, the energy output of flat plate collectors drops off rapidly in cloudy or cool conditions compared to the output of evacuated tube collectors that decrease less rapidly.
Heating of swimming pools Both pool covering systems floating atop the water and separate solar thermal collectors may be used for pool heating. Pool covering systems, whether solid sheets or floating disks, act as solar collectors and provide pool heating benefits which, depending on climate, may either supplement the solar thermal collectors discussed below or make them unnecessary. Solar thermal collectors for nonpotable pool water use are often made of plastic. Pool water, mildly corrosive due to chlorine, is circulated through the panels using the existing pool filter or supplemental pump. In mild environments, unglazed plastic collectors are more efficient as a direct system. In cold or windy environments evacuated tubes or flat plates in an indirect configuration do not have pool water pumped through them, they are used in conjunction with a heat exchanger that transfers the heat to pool water. This causes less corrosion. A fairly simple differential temperature controller is used to direct the water to the panels or heat exchanger either by turning a valve or operating the pump.. Once the pool water has reached the required temperature, a diverter valve is used to return pool water directly to the pool without heating. Many systems are configured as drainback systems where the water drains into the pool when the water pump is switched off.
The collector panels are usually mounted on a nearby roof, or ground-mounted on a tilted rack. Due to the low temperature difference between the air and the water, the panels are often formed collectors or unglazed flat plate collectors. A simple rule-of-thumb for the required panel area needed is 50% of the pool's surface area. This is for areas where pools are used in the summer season only, not year 'round. Adding solar collectors to a conventional outdoor pool, in a cold climate, can typically extend the pool's comfortable usage by some months or more if an insulating pool cover is also used. An active solar energy system analysis program may be used to optimize the solar pool heating system before it is built.
Economics, energy, environment, and system costs
A laundromat in California with panels on the roof providing hot washing water.
Energy production The amount of heat delivered by a solar water heating system depends primarily on the amount of heat delivered by the sun at a particular place (the insolation). In tropical places the insolation can be relatively high, e.g. 7 kW.h per day, whereas the insolation can be much lower in temperate areas where the days are shorter in winter, e.g. 3.2 kW.h per day. Even at the same latitude the average insolation can vary a great deal from location to location due to differences in local weather patterns and the amount of overcast. Useful calculators for estimating insolation at a site can be found with the Joint
Research Laboratory of the European Commission and the American National Renewable Energy Laboratory. Below is a table that gives a rough indication of the specifications and energy that could be expected from a solar water heating system involving some 2 m2 of absorber area of the collector, demonstrating two evacuated tube and three flat plate solar water heating systems. Certification information or figures calculated from those data are used. The bottom two rows give estimates for daily energy production (kW.h/day) for a tropical and a temperate scenario. These estimates are for heating water to 50 degrees C above ambient temperature. With most solar water heating systems, the energy output scales linearly with the surface area of the absorbers. Therefore, when comparing figures, take into account the absorber area of the collector because collectors with less absorber area yield less heat, even within the 2 m2 range. Specifications for many complete solar water heating systems and separate solar collectors can be found at Internet site of the SRCC. Daily energy production (kWth.h) of five solar thermal systems. The evac tube systems used below both have 20 tubes Evac Flat plate Flat plate Flat plate Evac tube Technology tube Direct Indirect Indirect Direct Thermosiphon Configuration active active active active 2 2.49 1.98 1.87 2.85 2.97 Overall size (m ) 2 2.21 1.98 1.72 2.85 2.96 Absorber size (m ) 0.68 0.74 0.61 0.57 0.46 Maximum efficiency Energy production (kW.h/day): - Insolation 5.3 3.9 3.3 4.8 4.0 3.2 kW.h/m2/day (temperate) - e.g. Zurich, Switzerland - Insolation 8.8 7.1 9.9 8.4 6.5 kW.h/m2/day (tropical) 11.2 - e.g. Phoenix, USA The figures are fairly similar between the above collectors, yielding some 4 kW.h/day in a temperate climate and some 8 kW.h/day in a more tropical climate when using a collector with an absorber area of about 2m2 in size. In the temperate scenario this is sufficient to heat 200 litres of water by some 17 degrees C. In the tropical scenario the equivalent heating would be by some 33 degrees C. Many thermosiphon systems are quite efficient and have comparable energy output to equivalent active systems. The efficiency of evacuated tube collectors is somewhat lower than for flat plate collectors because the absorbers are narrower than the tubes and the tubes have space between them, resulting in a significantly larger percentage of inactive overall collector area.
Some methods of comparison calculate the efficiency of evacuated tube collectors based on the actual absorber area and not on the 'roof area' of the system as has been done in the above table. The efficiency of the collectors becomes lower if one demands water with a very high temperature.
System cost In sunny, warm locations, where freeze protection is not necessary, an ICS (batch type) solar water heater can be extremely cost effective. In higher latitudes, there are often additional design requirements for cold weather, which add to system complexity. This has the effect of increasing the initial cost (but not the life-cycle cost) of a solar water heating system, to a level much higher than a comparable hot water heater of the conventional type. The biggest single consideration is therefore the large initial financial outlay of solar water heating systems. Offsetting this expense can take several years and the payback period is longer in temperate environments where the insolation is less intense. When calculating the total cost to own and operate, a proper analysis will consider that solar energy is free, thus greatly reducing the operating costs, whereas other energy sources, such as gas and electricity, can be quite expensive over time. Thus, when the initial costs of a solar system are properly financed and compared with energy costs, then in many cases the total monthly cost of solar heat can be less than other more conventional types of hot water heaters (also in conjunction with an existing hot water heater). At higher latitudes, solar heaters may be less effective due to lower solar energy, possibly requiring larger and/or dual-heating systems. In addition, federal and local incentives can be significant. The calculation of long term cost and payback period for a household SWH system depends on a number of factors. Some of these are: • • • • • • • • •
Price of purchasing solar water heater (more complex systems are more expensive) Efficiency of SWH system purchased Installation cost State or government subsidy for installation of a solar water heater Price of electricity per kW.h Number of kW.h of electricity used per month by a household Annual tax rebates or subsidy for using renewable energy Annual maintenance cost of SWH system Savings in annual maintenenance of conventional (electric/gas/oil) water heating system
The following table gives some idea of the cost and payback period to recover the costs. It does not take into account annual maintenance costs, annual tax rebates and installation costs. However the table does give an indication of the total cost and the order of magnitude of the payback period. The table assumes an energy savings of 140 kW.h per month (about 4.6 kW.h/day) due to SWH.
Costs and payback periods assuming a household electricity savings of 140 kW.h/month due to SWH (using 2010 data) System Effective Electricity Electricity Payback Country Currency Subsidy(%) cost cost cost/kW.h savings/month period(y) Australia $Aus 5000 40 3000 0.18 25 9.9 4000 50 2000 0.1 14 11.9 Belgium Euro 2500 0 2500 0.25 35 6.0 Brazil Real South ZA Rand 14000 15 11900 0.9 126 7.9 Africa United UK 4000 10 3600 0.11 15.4 19.4 Kingdom Pound United US$ 5000 30 3500 0.10 14 20.8 States Two points are clear from the above table. Firstly, the payback period is shorter in countries with a large amount of insolation and even in parts of the same country with more insolation. This is evident from the payback period less than 10 years in most southern hemisphere countries, listed above. This is partly because of good sunshine, allowing users in those countries to need smaller systems than in temperate areas. Secondly, even in the northern hemisphere countries where payback periods are often longer than 10 years, solar water heating is financially extremely efficient. This is partly because the SWH technology is efficient in capturing irradiation. The payback period for photovoltaic systems is much longer. In many cases the payback period for a SWH system is shortened if it supplies all or nearly all of the warm water requirements used by a household. Many SWH systems supply only a fraction of warm water needs and are augmented by gas or electric heating on a daily basis, thus extending the payback period of such a system. Solar leasing is now available in Spain for solar water heating systems from Pretasol with a typical system costing around 59 euros and rising to 99 euros per month for a system that would provide sufficient hot water for a typical family home of six persons. The payback period would be five years. Australia has instituted a system of Renewable Energy Credits, based on national renewable energy targets. This expands an older system based only on rebates.
Operational Carbon / Energy Footprint and Life Cycle Assessment Unfortunately this topic can seem a bit jargon-laden, so to clarify, here are some synonyms. Operational energy footprint (OEF) is also called energy parasitics ratio (EPR) or coefficient of performance (CoP).
Operational carbon footprint (OCF) is also called carbon clawback ratio (CCR). Life cycle assessment is usually referred to as LCA. The source of electricity in an active SWH system determines the extent to which a system contributes to atmospheric carbon during operation. Active solar thermal systems that use mains electricity to pump the fluid through the panels are called 'low carbon solar'. In most systems the pumping cancels the energy savings by about 8% and the carbon savings of the solar by about 20%. However, some new low power pumps will start operation with 1W and use a maximum of 20W. Assuming a solar collector panel delivering 4 kW.h/day and a pump running intermittently from mains electricity for a total of 6 hours during a 12-hour sunny day, the potentially negative effect of such a pump can be reduced to about 3% of the total power produced. The carbon footprint of such household systems varies substantially, depending on whether electricity or other fuels such as natural gas are being displaced by the use of solar. Except where a high proportion of electricity is already generated by non-fossil fuel means, natural gas, a common water heating fuel, in many countries, has typically only about 40% of the carbon intensity of mains electricity per unit of energy delivered. Therefore the 3% or 8% energy clawback in a gas home referred to above could therefore be considered 8% to 20% carbon clawback, a very low figure compared to technologies such as heat pumps. However, zero-carbon active solar thermal systems typically use a 5-30 W PV panel which faces in the same direction as the main solar heating panel and a small, low power diaphragm pump or centrifugal pump to circulate the water. This represents a zero operational carbon and energy footprint: a growing design goal for solar thermal systems. Work is also taking place in a number of parts of the world on developing alternative non-electrical zero carbon pumping systems. These are generally based on thermal expansion and phase changes of liquids and gases, a variety of which are under development. Now looking at a wider picture than just the operational environmental impacts, recognised standards can be used to deliver robust and quantitative life cycle assessment (LCA). LCA takes into account the total environmental cost of acquisition of raw materials, manufacturing, transport, using, servicing and disposing of the equipment. There are several aspects to such an assessment, including: • • •
The financial costs and gains incurred during the life of the equipment. The energy used during each of the above stages. The CO2 emissions due to each of the above stages.
Each of these aspects may present different trends with respect to a specific SWH device.
Financial assessment. The table in the previous section as well as several other studies suggest that the cost of production is gained during the first 5–12 years of use of the equipment, depending on the insolation, with cost efficiency increasing as the insolation does. In terms of energy, some 60% of the materials of a SWH system goes into the tank, with some 30% towards the collector (thermosiphon flat plate in this case) (Tsiligiridis et al.). In Italy, some 11 GJ of electricity are used in producing the equipment, with about 35% of the energy going towards the manufacturing the tank, with another 35% towards the collector and the main energy-related impact being emissions. The energy used in manufacturing is recovered within the first two to three years of use of the SWH system through heat captured by the equipment a this southern European study. Moving further north into colder, less sunny climates, the energy payback time of a solar water heating system in a UK climate is reported as only 2 years.. This figure was derived from the studied solar water heating system being: direct, retrofitted to an existing water store, PV pumped, freeze tolerant and of 2.8 sqm aperture. For comparison, a solar electric (PV) installation took around 5 years to reach energy payback, according to the same comparative study. In terms of CO2 emissions, a large degree of the emissions-saving traits of a SWH system is dependent on the degree to which water heating by gas or electricity is used to supplement solar heating of water. Using the Eco-indicator 99 points system as a yardstick (i.e. the yearly environmental load of an average European inhabitant) in Greece, a purely gas-driven system may be cheaper in terms of emissions than a solar system. This calculation assumes that the solar system produces about half of the hot water requirements of a household. The production of a test SWH system in Italy produced about 700 kg of CO2, with all the components of manufacture, use and disposal contributing small parts towards this. Maintenance was identified as an emissions-costly activity when the heat transfer fluid (Glycol-based) was periodically replaced. However, the emissions cost was recovered within about two years of use of the equipment through the emissions saved by solar water heating. In Australia, the life cycle emissions of a SWH system are also recovered fairly rapidly, where a SWH system has about 20% of the impact of an electrical water heater and half of the emissions impact of a gas water heater. Analysing their lower impact retrofit solar water heating system, Allen et al (qv) report a production CO2 impact of 337 kg, which is around half the environmental impact reported in the Ardente et al (qv) study. Where information based on established standards are available, the environmental transparency afforded by life cycle analysis allows consumers (of all products) to make increasingly well-informed product selection decisions. As for identifying sectors where this information is likely to appear first, environmental technology suppliers in the microgeneration and renewable energy technology arena are increasingly being pressed by consumers to report typical CoP and LCA figures for their products.
In summary, the energy and emissions cost of a SWH system forms a small part of the life cycle cost and can be recovered fairly rapidly during use of the equipment. Their environmental impacts can be reduced further by sustainable materials sourcing, using non-mains circulation, by reusing existing hot water stores and, in cold climates, by eliminating antifreeze replacement visits.
DIY solar water heating systems (DIY SWH) With an ever-rising do-it-yourself-community and their increasing environmental awareness, people have begun building their own (small-scale) solar water heating systems from scratch or buying easy to install kits. Plans for solar water heating systems are available on the Internet. and people have set about building them for their own domestic requirements. DIY solar water heating systems are usually much cheaper than commercial ones, and installation costs can sometimes be avoided as well. The DIY solar water heating systems are being used both in the developed world, as in the developing world, to generate hot water. Rather than build DIY solar water heating systems from scratch, many DIY solar enthusiasts are buying simple off-the-shelf solar DIY kits. In particular the new freeze tolerant, zero-carbon PV active systems, are becoming common in parts of Europe. Their simplicity enables them to be plumbed in quickly and safely without the need of a mains electrician. In such installations a low voltage PV powered controller, switches the variable speed pump. In some PV pumped systems, overnight display of temperatures is enabled by internal energy stores such as large supercapacitors.
Chapter-6 Photovoltaics (Second-Generation Technology)
Nellis Solar Power Plant at Nellis Air Force Base in the USA. These panels track the sun in one axis.
Photovoltaic system 'tree' in Styria, Austria Photovoltaics (PV) is a method of generating electrical power by converting solar radiation into direct current electricity using semiconductors that exhibit the photovoltaic effect. Photovoltaic power generation employs solar panels comprising a number of cells containing a photovoltaic material. Materials presently used for photovoltaics include monocrystalline silicon, polycrystalline silicon, amorphous silicon, cadmium telluride, and copper indium selenide/sulfide. Due to the growing demand for renewable energy sources, the manufacturing of solar cells and photovoltaic arrays has advanced considerably in recent years. As of 2010, solar photovoltaics generates electricity in more than 100 countries and, while yet comprising a tiny fraction of the 4800 GW total global power-generating
capacity from all sources, is the fastest growing power-generation technology in the world. Between 2004 and 2009, grid-connected PV capacity increased at an annual average rate of 60 percent, to some 21 GW. Such installations may be ground-mounted (and sometimes integrated with farming and grazing) or built into the roof or walls of a building, known as Building Integrated Photovoltaics or BIPV for short. Off-grid PV accounts for an additional 3–4 GW. Driven by advances in technology and increases in manufacturing scale and sophistication, the cost of photovoltaics has declined steadily since the first solar cells were manufactured. Net metering and financial incentives, such as preferential feed-in tariffs for solar-generated electricity, have supported solar PV installations in many countries.
Photovoltaic effect The photovoltaic effect is the creation of a voltage (or a corresponding electric current) in a material upon exposure to light. Though the photovoltaic effect is directly related to the photoelectric effect, the two processes are different and should be distinguished. In the photoelectric effect, electrons are ejected from a material's surface upon exposure to radiation of sufficient energy. The photovoltaic effect is different in that the generated electrons are transferred between different bands (i.e. from the valence to conduction bands) within the material, resulting in the buildup of a voltage between two electrodes. In most photovoltaic applications the radiation is sunlight and for this reason the devices are known as solar cells. In the case of a p-n junction solar cell, illumination of the material results in the creation of an electric current as excited electrons and the remaining holes are swept in different directions by the built-in electric field of the depletion region. The photovoltaic effect was first observed by Alexandre-Edmond Becquerel in 1839.
Solar cells
Solar cells produce electricity directly from sunlight Photovoltaics are best known as a method for generating electric power by using solar cells to convert energy from the sun into electricity. The photovoltaic effect refers to photons of light knocking electrons into a higher state of energy to create electricity. The term photovoltaic denotes the unbiased operating mode of a photodiode in which current through the device is entirely due to the transduced light energy. Virtually all photovoltaic devices are some type of photodiode. Solar cells produce direct current electricity from sun light, which can be used to power equipment or to recharge a battery. The first practical application of photovoltaics was to power orbiting satellites and other spacecraft, but today the majority of photovoltaic modules are used for grid connected power generation. In this case an inverter is required to convert the DC to AC. There is a smaller market for off-grid power for remote dwellings, boats, recreational vehicles, electric cars, roadside emergency telephones, remote sensing, and cathodic protection of pipelines.
Average solar irradiance, watts per square metre. Note that this is for a horizontal surface, whereas solar panels are normally mounted at an angle and receive more energy per unit area. The small black dots show the area of solar panels needed to generate all of the world's energy using 8% efficient photovoltaics. Cells require protection from the environment and are usually packaged tightly behind a glass sheet. When more power is required than a single cell can deliver, cells are electrically connected together to form photovoltaic modules, or solar panels. A single module is enough to power an emergency telephone, but for a house or a power plant the modules must be arranged in multiples as arrays. Although the selling price of modules is still too high to compete with grid electricity in most places, significant financial incentives in Japan and then Germany, Italy and France triggered a huge growth in demand, followed quickly by production. In 2008, Spain installed 45% of all photovoltaics, but a change in law limiting the feed-in tariff is expected to cause a precipitous drop in the rate of new installations there, from an extra 2500 MW in 2008, to an expected additional 375 MW in 2009. A significant market has emerged in off-grid locations for solar-power-charged storagebattery based solutions. These often provide the only electricity available. The first commercial installation of this kind was in 1966 on Ogami Island in Japan to transition Ogami Lighthouse from gas torch to fully self-sufficient electrical power. Due to the growing demand for renewable energy sources, the manufacture of solar cells and photovoltaic arrays has advanced dramatically in recent years.
Photovoltaic production has been increasing by an average of more than 20 percent each year since 2002, making it the world’s fastest-growing energy technology. At the end of 2009, the cumulative global PV installations surpassed 21,000 megawatts. Germany installed a record 3,800 MW of solar PV in 2009. Roughly 90% of this generating capacity consists of grid-tied electrical systems. Such installations may be groundmounted (and sometimes integrated with farming and grazing) or built into the roof or walls of a building, known as Building Integrated Photovoltaics or BIPV for short. Solar PV power stations today have capacities ranging from 10–60 MW although proposed solar PV power stations will have a capacity of 150 MW or more. World solar photovoltaic (PV) installations were 2.826 gigawatts peak (GWp) in 2007, and 5.95 gigawatts in 2008, and 7.5 gigawatts in 2009. The three leading countries (Germany, Japan and the US) represent nearly 89% of the total worldwide PV installed capacity. According to Navigant Consulting and Electronic Trend Publications, the estimated PV worldwide installations outlooks of 2012 are 18.8GW and 12.3GW respectively. Notably, the manufacture of solar cells and modules had expanded in recent years. Germany installed a record 3,800 MW of solar PV in 2009; in contrast, the US installed about 500 MW in 2009. The previous record, 2,600 MW, was set by Spain in 2008. Germany was also the fastest growing major PV market in the world from 2006 to 2007 industry observers speculate that Germany could install more than 4,500 MW in 2010. The German PV industry generates over 10,000 jobs in production, distribution and installation. By the end of 2006, nearly 88% of all solar PV installations in the EU were in grid-tied applications in Germany. Photovoltaic power capacity is measured as maximum power output under standardized test conditions (STC) in "Wp" (Watts peak). The actual power output at a particular point in time may be less than or greater than this standardized, or "rated," value, depending on geographical location, time of day, weather conditions, and other factors. Solar photovoltaic array capacity factors are typically under 25%, which is lower than many other industrial sources of electricity. Therefore the 2008 installed base peak output would have provided an average output of 3.04 GW (assuming 20% × 15,200 MWp). This represented 0.15 percent of global demand at the time. The EPIA/Greenpeace Advanced Scenario shows that by the year 2030, PV systems could be generating approximately 1,864 GW of electricity around the world. This means that, assuming a serious commitment is made to energy efficiency, enough solar power would be produced globally in twenty-five years’ time to satisfy the electricity needs of almost 14% of the world’s population.
Current developments
Map of solar electricity potential in Europe. Germany is the current leader in solar production. Photovoltaic panels based on crystalline silicon modules are being partially replaced in the market by panels that employ thin-film solar cells (CdTe CIGS, amorphous Si, microcrystalline Si), which are rapidly growing and are expected to account for 31 percent of the global installed power by 2013. Other developments include casting wafers instead of sawing, concentrator modules, 'Sliver' cells, and continuous printing processes. Due to economies of scale solar panels get less costly as people use and buy more — as manufacturers increase production to meet demand, the cost and price is expected to drop in the years to come. By early 2006, the average cost per installed watt for a residential sized system was about USD 7.50 to USD 9.50, including panels, inverters, mounts, and electrical items.
In 2006 investors began offering free solar panel installation in return for a 25 year contract, or Power Purchase Agreement, to purchase electricity at a fixed price, normally set at or below current electric rates. It is expected that by 2009 over 90% of commercial photovoltaics installed in the United States will be installed using a power purchase agreement. An innovative financing arrangement in Berkeley, California, funded by grants from the EPA and the Bay Area Air Quality Management District, lends money to a homeowner for solar system, to be repaid via an additional tax assessment on the property which remains in place for 20 years. This allows installation of the solar system at "relatively little up-front cost to the property owner." The current market leader in solar panel efficiency (measured by energy conversion ratio) is SunPower, a San Jose based company. Sunpower's cells have a conversion ratio of 24.2%, well above the market average of 12–18%. However, advances past this efficiency mark are being pursued in academia and R&D labs with efficiencies of 42% achieved at the University of Delaware in conjunction with DuPont by means of concentration of light The highest efficiencies achieved without concentration include Sharp Corporation at 35.8% using a proprietary triple-junction manufacturing technology in 2009, and Boeing Spectrolab (40.7% also using a triple layer design). A March 2010 experimental demonstration of a design by a Caltech group which has an absorption efficiency of 85% in sunlight and 95% at certain wavelengths (it is claimed to have near perfect quantum efficiency). However, absorption efficiency should not be confused with the sunlight-to-electricity conversion efficiency.
Applications Power stations
President Barack Obama speaks at the DeSoto Next Generation Solar Energy Center.
As of November 2010, the largest photovoltaic (PV) power plants in the world are the Finsterwalde Solar Park (Germany, 80.7 MW), Sarnia Photovoltaic Power Plant (Canada, 80 MW), Rovigo Photovoltaic Power Plant (Italy, 70 MW), Olmedilla Photovoltaic Park (Spain, 60 MW), the Strasskirchen Solar Park (Germany, 54 MW), the Lieberose Photovoltaic Park (Germany, 53 MW) and the Puertollano Photovoltaic Park (Spain, 50 MW). Larger power stations are under construction, some proposed will have a capacity of 150 MW or more. World's largest photovoltaic power stations (50 MW or larger) Nominal Production Capacity (Annual Notes PV power station Country Power factor GW·h) (MWp) Phase I completed Finsterwalde Solar Germany 80.7 2009, phase II and III Park 2010 Sarnia Photovoltaic Completed October Canada 80 120 0.17 Power Plant 2010 Rovigo Completed November Photovoltaic Power Italy 70 2010 Plant Olmedilla Completed September Spain 60 85 0.16 Photovoltaic Park 2008 Strasskirchen Solar Germany 54 57 0.12 Park Lieberose Germany 53 53 0.11 Completed in 2009 Photovoltaic Park Topaz Solar Farm is a proposed 550 MW solar photovoltaic power plant which is to be built northwest of California Valley in the US at a cost of over $1 billion. Built on 9.5 square miles (25 km2) of ranchland, the project would utilize thin-film PV panels designed and manufactured by OptiSolar in Hayward and Sacramento. The project would deliver approximately 1,100 gigawatt-hours (GW·h) annually of renewable energy. The project is expected to begin construction in 2010, begin power delivery in 2011, and be fully operational by 2013. High Plains Ranch is a proposed 250 MW solar photovoltaic power plant which is to be built by SunPower in the Carrizo Plain, northwest of California Valley.
In buildings Photovoltaic arrays are often associated with buildings: either integrated into them, mounted on them or mounted nearby on the ground.
Arrays are most often retrofitted into existing buildings, usually mounted on top of the existing roof structure or on the existing walls. Alternatively, an array can be located separately from the building but connected by cable to supply power for the building. In 2010, more than four-fifths of the 9,000 MW of solar PV operating in Germany was installed on rooftops.
Photovoltaic solar panels on a house roof. Building-integrated photovoltaics (BIPV) are increasingly incorporated into new domestic and industrial buildings as a principal or ancillary source of electrical power. Typically, an array is incorporated into the roof or walls of a building. Roof tiles with integrated PV cells are also common. The power output of photovoltaic systems for installation in buildings is usually described in kilowatt-peak units (kWp).
In transport PV has traditionally been used for electric power in space. PV is rarely used to provide motive power in transport applications, but is being used increasingly to provide auxiliary power in boats and cars. A self-contained solar vehicle would have limited power and low utility, but a solar-charged vehicle would allow use of solar power for transportation. Solar-powered cars have been demonstrated.
Standalone devices
Solar parking meter. Until a decade or so ago, PV was used frequently to power calculators and novelty devices. Improvements in integrated circuits and low power LCD displays make it possible to power such devices for several years between battery changes, making PV use less common. In contrast, solar powered remote fixed devices have seen increasing use recently in locations where significant connection cost makes grid power prohibitively expensive. Such applications include water pumps, parking meters, emergency telephones, trash compactors, temporary traffic signs, and remote guard posts & signals.
Rural electrification Developing countries where many villages are often more than five kilometers away from grid power have begun using photovoltaics. In remote locations in India a rural lighting program has been providing solar powered LED lighting to replace kerosene lamps. The solar powered lamps were sold at about the cost of a few month's supply of kerosene. Cuba is working to provide solar power for areas that are off grid. These are areas where the social costs and benefits offer an excellent case for going solar though the lack of profitability could relegate such endeavors to humanitarian goals.
Solar roadways A 45 mi (72 km) section of roadway in Idaho is being used to test the possibility of installing solar panels into the road surface, as roads are generally unobstructed to the sun and represent about the percentage of land area needed to replace other energy sources with solar power.
Solar Power satellites Design studies of large solar power collection satellites have been conducted for decades. The idea was first proposed by Peter Glaser, then of Arthur D. Little Inc; NASA conducted a long series of engineering and economic feasibility studies in the 1970s, and interest has revived in first years of the 21st century. From a practical economic viewpoint, the key issue for such satellites appears to be the launch cost. Additional considerations will include developing space based assembly techniques, but they seem to be less a hurdle than the capital cost. These will be reduced as photovoltaic cell costs are reduced or alternatively efficiency increased.
Performance Temperature Generally, temperatures above room temperature reduce the performance of photovoltaics.
Optimum Orientation of Solar Panels For best performance, terrestrial PV systems aim to maximize the time they face the sun. Solar trackers aim to achieve this by moving PV panels to follow the sun. The increase can be by as much as 20% in winter and by as much as 50% in summer. Static mounted systems can be optimized by analysis of the Sun path. Panels are often set to latitude tilt, an angle equal to the latitude, but performance can be improved by adjusting the angle for summer or winter.
Advantages The 89 petawatts of sunlight reaching the Earth's surface is plentiful – almost 6,000 times more than the 15 terawatts equivalent of average power consumed by humans. Additionally, solar electric generation has the highest power density (global mean of 170 W/m²) among renewable energies. Solar power is pollution-free during use. Production end-wastes and emissions are manageable using existing pollution controls. End-of-use recycling technologies are under development and policies are being produced that encourage recycling from producers. PV installations can operate for many years with little maintenance or intervention after their initial set-up, so after the initial capital cost of building any solar power plant, operating costs are extremely low compared to existing power technologies. Solar electric generation is economically superior where grid connection or fuel transport is difficult, costly or impossible. Long-standing examples include satellites, island communities, remote locations and ocean vessels. When grid-connected, solar electric generation replaces some or all of the highest-cost electricity used during times of peak demand (in most climatic regions). This can reduce grid loading, and can eliminate the need for local battery power to provide for use in times of darkness. These features are enabled by net metering. Time-of-use net metering can be highly favorable, but requires newer electronic metering, which may still be impractical for some users. Grid-connected solar electricity can be used locally thus reducing transmission/distribution losses (transmission losses in the US were approximately 7.2% in 1995). Compared to fossil and nuclear energy sources, very little research money has been invested in the development of solar cells, so there is considerable room for improvement. Nevertheless, experimental high efficiency solar cells already have efficiencies of over 40% in case of concentrating photovoltaic cells and efficiencies are rapidly rising while mass-production costs are rapidly falling.
Disadvantages Photovoltaics are costly to install. While the modules are often warranteed for upwards of 20 years, much of the investment in a home-mounted system may be lost if the homeowner moves and the buyer puts less value on the system than the seller. Solar electricity is seen to be expensive. With the UK Feed-In Tariff for green solar energy, Solar PV has been made more accessible to homeowners. Under the scheme,
homeowners can generate both free electricity, and a fee per kWh sold to the grid "Solar PV as a Domestic Investment Opportunity: Solar electricity is not produced at night and is much reduced in cloudy conditions. Therefore, a storage or complementary power system is required. Solar electricity production depends on the limited power density of the location's insolation. Average daily output of a flat plate collector at latitude tilt in the contiguous US is 3–7 kilowatt·h/m² and on average lower in Europe. Solar cells produce DC which must be converted to AC (using a grid tie inverter) when used in existing distribution grids. This incurs an energy loss of 4–12%.
Chapter-7 Wind Power (Second-generation technology)
Wind power: worldwide installed capacity 1996-2008
Burbo Bank Offshore Wind Farm, at the entrance to the River Mersey in North West England.
A modern wind turbine in rural scenery. Wind power is the conversion of wind energy into a useful form of energy, such as using wind turbines to make electricity, wind mills for mechanical power, wind pumps for pumping water or drainage, or sails to propel ships. At the end of 2009, worldwide nameplate capacity of wind-powered generators was 159.2 gigawatts (GW). Energy production was 340 TWh, which is about 2% of worldwide electricity usage; and has doubled in the past three years. Several countries have achieved relatively high levels of wind power penetration (with large governmental subsidies), such as 20% of stationary electricity production in Denmark, 14% in Ireland and Portugal, 11% in Spain, and 8% in Germany in 2009. As of May 2009, 80 countries around the world are using wind power on a commercial basis. Large-scale wind farms are connected to the electric power transmission network; smaller facilities are used to provide electricity to isolated locations. Utility companies increasingly buy back surplus electricity produced by small domestic turbines. Wind energy, as an alternative to fossil fuels, is plentiful, renewable, widely distributed, clean, and produces no greenhouse gas emissions during operation. However, the construction of wind farms is not universally welcomed because of their visual impact and other effects on the environment. Wind power is non-dispatchable, meaning that for economic operation, all of the available output must be taken when it is available. Other resources, such as hydropower, and load management techniques must be used to match supply with demand. The
intermittency of wind seldom creates problems when using wind power to supply a low proportion of total demand, but as the proportion rises, problems are created such as increased costs, the need to upgrade the grid, and a lowered ability to supplant conventional production. Power management techniques such as exporting excess power to neighboring areas or reducing demand when wind production is low, can mitigate these problems.
History
Medieval depiction of a wind mill
Windmills are typically installed in favourable windy locations. In the image, wind power generators in Spain near an Osborne bull Humans have been using wind power for at least 5,500 years to propel sailboats and sailing ships. Windmills have been used for irrigation pumping and for milling grain since the 7th century AD in what is now Afghanistan, Iran and Pakistan. In the United States, the development of the "water-pumping windmill" was the major factor in allowing the farming and ranching of vast areas otherwise devoid of readily accessible water. Windpumps contributed to the expansion of rail transport systems throughout the world, by pumping water from water wells for the steam locomotives. The multi-bladed wind turbine atop a lattice tower made of wood or steel was, for many years, a fixture of the landscape throughout rural America. When fitted with generators and battery banks, small wind machines provided electricity to isolated farms. In July 1887, a Scottish academic, Professor James Blyth, undertook wind power experiments that culminated in a UK patent in 1891. In the United States, Charles F. Brush produced electricity using a wind powered machine, starting in the winter of 18871888, which powered his home and laboratory until about 1900. In the 1890s, the Danish scientist and inventor Poul la Cour constructed wind turbines to generate electricity, which was then used to produce hydrogen. These were the first of what was to become the modern form of wind turbine. Small wind turbines for lighting of isolated rural buildings were widespread in the first part of the 20th century. Larger units intended for connection to a distribution network
were tried at several locations including Balaklava USSR in 1931 and in a 1.25 megawatt (MW) experimental unit in Vermont in 1941. The modern wind power industry began in 1979 with the serial production of wind turbines by Danish manufacturers Kuriant, Vestas, Nordtank, and Bonus. These early turbines were small by today's standards, with capacities of 20–30 kW each. Since then, they have increased greatly in size, with the Enercon E-126 capable of delivering up to 7 MW, while wind turbine production has expanded to many countries.
Wind energy
Distribution of wind speed (red) and energy (blue) for all of 2002 at the Lee Ranch facility in Colorado. The histogram shows measured data, while the curve is the Rayleigh model distribution for the same average wind speed. Energy is the Betz limit through a 100 m (328 ft) diameter circle facing directly into the wind. Total energy for the year through that circle was 15.4 gigawatt-hours (GW·h). The Earth is unevenly heated by the sun, such that the poles receive less energy from the sun than the equator; along with this, dry land heats up (and cools down) more quickly than the seas do. The differential heating drives a global atmospheric convection system reaching from the Earth's surface to the stratosphere which acts as a virtual ceiling. Most of the energy stored in these wind movements can be found at high altitudes where continuous wind speeds of over 160 km/h (99 mph) occur. Eventually, the wind energy is converted through friction into diffuse heat throughout the Earth's surface and the atmosphere. The total amount of economically extractable power available from the wind is considerably more than present human power use from all sources. An estimated 72 terawatt (TW) of wind power on the Earth potentially can be commercially viable,
compared to about 15 TW average global power consumption from all sources in 2005. Not all the energy of the wind flowing past a given point can be recovered.
Distribution of wind speed The strength of wind varies, and an average value for a given location does not alone indicate the amount of energy a wind turbine could produce there. To assess the frequency of wind speeds at a particular location, a probability distribution function is often fit to the observed data. Different locations will have different wind speed distributions. The Weibull model closely mirrors the actual distribution of hourly wind speeds at many locations. The Weibull factor is often close to 2 and therefore a Rayleigh distribution can be used as a less accurate, but simpler model. Because so much power is generated by higher wind speed, much of the energy comes in short bursts. The 2002 Lee Ranch sample is telling; half of the energy available arrived in just 15% of the operating time. The consequence is that wind energy from a particular turbine or wind farm does not have as consistent an output as fuel-fired power plants; utilities that use wind power provide power from starting existing generation for times when the wind is weak thus wind power is primarily a fuel saver rather than a capacity saver. Making wind power more consistent requires that various existing technologies and methods be extended, in particular the use of stronger inter-regional transmission lines to link widely distributed wind farms. Problems of variability are addressed by grid energy storage, batteries, pumped-storage hydroelectricity and energy demand management.
Electricity generation
Typical components of a wind turbine (gearbox, rotor shaft and brake assembly) being lifted into position In a wind farm, individual turbines are interconnected with a medium voltage (often 34.5 kV), power collection system and communications network. At a substation, this medium-voltage electric current is increased in voltage with a transformer for connection to the high voltage electric power transmission system. The surplus power produced by domestic microgenerators can, in some jurisdictions, be fed into the network and sold to the utility company, producing a retail credit for the microgenerators' owners to offset their energy costs.
Grid management Induction generators, often used for wind power, require reactive power for excitation so substations used in wind-power collection systems include substantial capacitor banks for power factor correction. Different types of wind turbine generators behave differently during transmission grid disturbances, so extensive modelling of the dynamic electromechanical characteristics of a new wind farm is required by transmission system operators to ensure predictable stable behaviour during system faults. In particular,
induction generators cannot support the system voltage during faults, unlike steam or hydro turbine-driven synchronous generators. Doubly-fed machines generally have more desirable properties for grid interconnection. Transmission systems operators will supply a wind farm developer with a grid code to specify the requirements for interconnection to the transmission grid. This will include power factor, constancy of frequency and dynamic behavior of the wind farm turbines during a system fault.
Capacity factor
Worldwide installed capacity 1997–2020 [MW], developments and prognosis. Since wind speed is not constant, a wind farm's annual energy production is never as much as the sum of the generator nameplate ratings multiplied by the total hours in a year. The ratio of actual productivity in a year to this theoretical maximum is called the capacity factor. Typical capacity factors are 20–40%, with values at the upper end of the range in particularly favourable sites. For example, a 1 MW turbine with a capacity factor of 35% will not produce 8,760 MW·h in a year (1 × 24 × 365), but only 1 × 0.35 × 24 × 365 = 3,066 MW·h, averaging to 0.35 MW. Online data is available for some locations and the capacity factor can be calculated from the yearly output. Unlike fueled generating plants, the capacity factor is limited by the inherent properties of wind. Capacity factors of other types of power plant are based mostly on fuel cost, with a small amount of downtime for maintenance. Nuclear plants have low incremental fuel cost, and so are run at full output and achieve a 90% capacity factor. Plants with higher fuel cost are throttled back to follow load. Gas turbine plants using natural gas as fuel may be very expensive to operate and may be run only to meet peak power demand. A gas turbine plant may have an annual capacity factor of 5–25% due to relatively high energy production cost. In a 2008 study released by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy, the capacity factor achieved by the wind turbine fleet is shown to be increasing as the technology improves. The capacity factor achieved by new wind turbines in 2004 and 2005 reached 36%.
Penetration
Kitegen Wind energy "penetration" refers to the fraction of energy produced by wind compared with the total available generation capacity. There is no generally accepted "maximum" level of wind penetration. The limit for a particular grid will depend on the existing generating plants, pricing mechanisms, capacity for storage or demand management, and other factors. An interconnected electricity grid will already include reserve generating and transmission capacity to allow for equipment failures; this reserve capacity can also serve to regulate for the varying power generation by wind plants. Studies have indicated that 20% of the total electrical energy consumption may be incorporated with minimal difficulty. These studies have been for locations with geographically dispersed wind farms, some degree of dispatchable energy, or hydropower with storage capacity, demand management, and interconnection to a large grid area export of electricity when needed. Beyond this level, there are few technical limits, but the economic implications become more significant. Electrical utilities continue to study the effects of large (20% or more) scale penetration of wind generation on system stability and economics. At present, a few grid systems have penetration of wind energy above 5%: Denmark (values over 19%), Spain and Portugal (values over 11%), Germany and the Republic of Ireland (values over 6%). But even with a modest level of penetration, there can be times where wind power provides a substantial percentage of the power on a grid. For example,
in the morning hours of 8 November 2009, wind energy produced covered more than half the electricity demand in Spain, setting a new record. This was an instance where demand was very low but wind power generation was very high.
Wildorado Wind Ranch in Oldham County in the Texas Panhandle, as photographed from U.S. Route 385
Intermittency and penetration limits Electricity generated from wind power can be highly variable at several different timescales: from hour to hour, daily, and seasonally. Annual variation also exists, but is not as significant. Related to variability is the short-term (hourly or daily) predictability of wind plant output. Like other electricity sources, wind energy must be "scheduled". Wind power forecasting methods are used, but predictability of wind plant output remains low for short-term operation. Because instantaneous electrical generation and consumption must remain in balance to maintain grid stability, this variability can present substantial challenges to incorporating large amounts of wind power into a grid system. Intermittency and the non-dispatchable nature of wind energy production can raise costs for regulation, incremental operating reserve, and (at high penetration levels) could require an increase in the already existing energy demand management, load shedding, or storage solutions or system
interconnection with HVDC cables. At low levels of wind penetration, fluctuations in load and allowance for failure of large generating units requires reserve capacity that can also regulate for variability of wind generation. Wind power can be replaced by other power stations during low wind periods. Transmission networks must already cope with outages of generation plant and daily changes in electrical demand. Systems with large wind capacity components may need more spinning reserve (plants operating at less than full load). Pumped-storage hydroelectricity or other forms of grid energy storage can store energy developed by high-wind periods and release it when needed. Stored energy increases the economic value of wind energy since it can be shifted to displace higher cost generation during peak demand periods. The potential revenue from this arbitrage can offset the cost and losses of storage; the cost of storage may add 25% to the cost of any wind energy stored, but it is not envisaged that this would apply to a large proportion of wind energy generated. The 2 GW Dinorwig pumped storage plant in Wales evens out electrical demand peaks, and allows base-load suppliers to run their plant more efficiently. Although pumped storage power systems are only about 75% efficient, and have high installation costs, their low running costs and ability to reduce the required electrical base-load can save both fuel and total electrical generation costs. In particular geographic regions, peak wind speeds may not coincide with peak demand for electrical power. In the US states of California and Texas, for example, hot days in summer may have low wind speed and high electrical demand due to air conditioning. Some utilities subsidize the purchase of geothermal heat pumps by their customers, to reduce electricity demand during the summer months by making air conditioning up to 70% more efficient; widespread adoption of this technology would better match electricity demand to wind availability in areas with hot summers and low summer winds. Another option is to interconnect widely dispersed geographic areas with an HVDC "Super grid". In the USA it is estimated that to upgrade the transmission system to take in planned or potential renewables would cost at least $60 billion. In the UK, demand for electricity is higher in winter than in summer, and so are wind speeds. Solar power tends to be complementary to wind. On daily to weekly timescales, high pressure areas tend to bring clear skies and low surface winds, whereas low pressure areas tend to be windier and cloudier. On seasonal timescales, solar energy typically peaks in summer, whereas in many areas wind energy is lower in summer and higher in winter. Thus the intermittencies of wind and solar power tend to cancel each other somewhat. A demonstration project at the Massachusetts Maritime Academy shows the effect. The Institute for Solar Energy Supply Technology of the University of Kassel pilot-tested a combined power plant linking solar, wind, biogas and hydrostorage to provide load-following power around the clock, entirely from renewable sources. A report on Denmark's wind power noted that their wind power network provided less than 1% of average demand 54 days during the year 2002. Wind power advocates argue that these periods of low wind can be dealt with by simply restarting existing power stations that have been held in readiness or interlinking with HVDC. Electrical grids with
slow-responding thermal power plants and without ties to networks with hydroelectric generation may have to limit the use of wind power. Three reports on the wind variability in the UK issued in 2009, generally agree that variability of wind needs to be taken into account, but it does not make the grid unmanageable; and the additional costs, which are modest, can be quantified. A 2006 International Energy Agency forum presented costs for managing intermittency as a function of wind-energy's share of total capacity for several countries, as shown: Increase in system operation costs, Euros per MW·h, for 10% and 20% wind share 10% 20% Germany 2.5 3.2 Denmark 0.4 0.8 Finland 0.3 1.5 Norway 0.1 0.3 Sweden 0.3 0.7
Capacity credit and fuel saving Many commentators concentrate on whether or not wind has any "capacity credit" without defining what they mean by this and its relevance. Wind does have a capacity credit, using a widely accepted and meaningful definition, equal to about 20% of its rated output (but this figure varies depending on actual circumstances). This means that reserve capacity on a system equal in MW to 20% of added wind could be retired when such wind is added without affecting system security or robustness. But the precise value is irrelevant since the main value of wind (in the UK, worth 5 times the capacity credit value) is its fuel and CO2 savings. According to a 2007 Stanford University study published in the Journal of Applied Meteorology and Climatology, interconnecting ten or more wind farms can allow an average of 33% of the total energy produced to be used as reliable, baseload electric power, as long as minimum criteria are met for wind speed and turbine height.
Installation placement Good selection of a wind turbine site is critical to economic development of wind power. Aside from the availability of wind itself, other factors include the availability of transmission lines, value of energy to be produced, cost of land acquisition, land use considerations, and environmental impact of construction and operations. Off-shore locations may offset their higher construction cost with higher annual load factors, thereby reducing cost of energy produced. Wind farm designers use specialized wind energy software applications to evaluate the impact of these issues on a given wind farm design.
Wind power density (WPD) is a calculation of the effective power of the wind at a particular location. A map showing the distribution of wind power density is a first step in identifying possible locations for wind turbines. In the United States, the National Renewable Energy Laboratory classifies wind power density into ascending classes. The larger the WPD at a location, the higher it is rated by class. Wind power classes 3 (300– 400 W/m2 at 50 m altitude) to 7 (800–2000 W/m2 at 50 m altitude) are generally considered suitable for wind power development. There are 625,000 km2 in the contiguous United States that have class 3 or higher wind resources and which are within 10 km of electric transmission lines. If this area is fully utilized for wind power, it would produce power at the average continuous equivalent rate of 734 GWe. For comparison, in 2007 the US consumed electricity at an average rate of 474 GW, from a total generating capacity of 1,088 GW.
Wind power usage
# 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Installed windpower capacity (MW) Nation 2005 2006 2007 2008 40,722 48,122 56,614 65,255 European Union United States 9,149 11,603 16,819 25,170 Germany 18,428 20,622 22,247 23,903 1,266 2,599 5,912 12,210 China 10,028 11,630 15,145 16,740 Spain 4,430 6,270 7,850 9,587 India 1,718 2,123 2,726 3,537 Italy 779 1,589 2,477 3,426 France United Kingdom 1,353 1,963 2,389 3,288 1,022 1,716 2,130 2,862 Portugal 3,132 3,140 3,129 3,164 Denmark Canada 683 1,460 1,846 2,369 1,236 1,571 1,759 2,237 Netherlands 1,040 1,309 1,528 1,880 Japan Australia 579 817 817 1,494 Sweden 509 571 831 1,067 Ireland 495 746 805 1,245 573 758 873 990 Greece 819 965 982 995 Austria 20 65 207 433 Turkey Poland 83 153 276 472 29 237 247 339 Brazil 167 194 287 384 Belgium
2009 74,767 35,159 25,777 25,104 19,149 10,925 4,850 4,410 4,070 3,535 3,465 3,319 2,229 2,056 1,712 1,560 1,260 1,087 995 801 725 606 563
23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
Mexico 2 84 85 85 520 New Zealand 168 171 322 325 497 104 188 280 358 436 Taiwan 268 325 333 428 431 Norway 145 230 310 390 430 Egypt 119 176 192 278 348 South Korea 64 64 125 125 253 Morocco Hungary 18 61 65 127 201 30 57 116 150 192 Czech Republic Bulgaria 14 36 57 158 177 ? ? ? 20 168 Chile Finland 82 86 110 143 147 Estonia ? ? 59 78 142 Costa Rica ? ? ? 74 123 77 86 89 90 94 Ukraine Iran 32 47 67 82 91 Lithuania 7 56 50 54 91 Other Europe (non EU27) 391 494 601 1022 1385 Rest of Americas 155 159 184 210 175 Rest of Africa 52 52 51 56 91 & Middle East Rest of Asia 27 27 27 36 51 & Oceania World total (MW) 59,024 74,151 93,927 121,188 157,899
There are now many thousands of wind turbines operating, with a total nameplate capacity of 157,899 MW of which wind power in Europe accounts for 48% (2009). World wind generation capacity more than quadrupled between 2000 and 2006, doubling about every three years. 81% of wind power installations are in the US and Europe. The share of the top five countries in terms of new installations fell from 71% in 2004 to 62% in 2006, but climbed to 73% by 2008 as those countries — the United States, Germany, Spain, China, and India — have seen substantial capacity growth in the past two years. The World Wind Energy Association forecast that, by 2010, over 200 GW of capacity would have been installed worldwide, up from 73.9 GW at the end of 2006, implying an anticipated net growth rate of more than 28% per year. Wind accounts for nearly one-fifth of electricity generated in Denmark — the highest percentage of any country — and it is tenth in the world in total wind power generation. Denmark is prominent in the manufacturing and use of wind turbines, with a commitment made in the 1970s to eventually produce half of the country's power by wind.
In recent years, the US has added substantial amounts of wind power generation capacity, growing from just over 6 GW at the end of 2004 to over 35 GW at the end of 2009. The U.S. is currently the world's leader in wind power generation capacity. The country as a whole generates just 2.4% of its electrical power from wind, but several states generate substantial amounts of wind power. Texas is the state with the largest amount of generation capacity with 9,410 MW installed. This would have ranked sixth in the world, were Texas a separate country. Iowa is the state with the highest percentage of wind generation, at 14.2% in 2009. California was one of the incubators of the modern wind power industry, and led the U.S. in installed capacity for many years. As of mid-2010, fourteen U..S. states had wind power generation capacities in excess of 1000 MW. U.S. Department of Energy studies have concluded that wind from the Great Plains states of Texas, Kansas, and North Dakota could provide enough electricity to power the entire nation, and that offshore wind farms could do the same job. China had originally set a generating target of 30,000 MW by 2020 from renewable energy sources, but reached 22,500 MW by end of 2009 and could easily surpass 30,000 MW by end of 2010. Indigenous wind power could generate up to 253,000 MW. A Chinese renewable energy law was adopted in November 2004, following the World Wind Energy Conference organized by the Chinese and the World Wind Energy Association. By 2008, wind power was growing faster in China than the government had planned, and indeed faster in percentage terms than in any other large country, having more than doubled each year since 2005. Policymakers doubled their wind power prediction for 2010, after the wind industry reached the original goal of 5 GW three years ahead of schedule. Current trends suggest an actual installed capacity near 20 GW by 2010, with China shortly thereafter pursuing the United States for the world wind power lead. India ranks 5th in the world with a total wind power capacity of 10,925 MW in 2009, or 3% of all electricity produced in India. The World Wind Energy Conference in New Delhi in November 2006 has given additional impetus to the Indian wind industry. Muppandal village in Tamil Nadu state, India, has several wind turbine farms in its vicinity, and is one of the major wind energy harnessing centres in India led by majors like Suzlon, Vestas, Micon among others. Mexico recently opened La Venta II wind power project as a step toward reducing Mexico's consumption of fossil fuels. The 88 MW project is the first of its kind in Mexico, and will provide 13 percent of the electricity needs of the state of Oaxaca. By 2012 the project will have a capacity of 3,500 MW. In May 2010, Sempra Energy announced it would build a wind farm in Baja California, with a capacity of at least 1,000 MW, at a cost of $5.5 billion. Another growing market is Brazil, with a wind potential of 143 GW. South Africa has a proposed station situated on the West Coast north of the Olifants River mouth near the town of Koekenaap, east of Vredendal in the Western Cape
province. The station is proposed to have a total output of 100 MW although there are negotiations to double this capacity. The plant could be operational by 2010. France has announced a target of 12,500 MW installed by 2010, though their installation trends over the past few years suggest they'll fall well short of their goal. Canada experienced rapid growth of wind capacity between 2000 and 2006, with total installed capacity increasing from 137 MW to 1,451 MW, and showing an annual growth rate of 38%. Particularly rapid growth was seen in 2006, with total capacity doubling from the 684 MW at end-2005. This growth was fed by measures including installation targets, economic incentives and political support. For example, the Ontario government announced that it will introduce a feed-in tariff for wind power, referred to as 'Standard Offer Contracts', which may boost the wind industry across the province. In Quebec, the provincially owned electric utility plans to purchase an additional 2000 MW by 2013. By 2025, Canada will reach its capacity of 55,000 MW of wind energy, or 20% of the country's energy needs.
Power analysis Due to ever increasing sizes of turbines which hit maximum power at lower speeds energy produced has been rising faster than nameplate power capacity. Energy more than doubled between 2006 and 2008 in the table above, yet nameplate capacity (table on left) grew by 63% in the same period.
Small-scale wind power
This wind turbine charges a 12 V battery to run 12 V appliances. Small-scale wind power is the name given to wind generation systems with the capacity to produce up to 50 kW of electrical power. Isolated communities, that may otherwise rely on diesel generators may use wind turbines to displace diesel fuel consumption. Individuals may purchase these systems to reduce or eliminate their dependence on grid electricity for economic or other reasons, or to reduce their carbon footprint. Wind turbines have been used for household electricity generation in conjunction with battery storage over many decades in remote areas. Grid-connected wind turbines may use grid energy storage, displacing purchased energy with local production when available. Off-grid system users can either adapt to intermittent power or use batteries, photovoltaic or diesel systems to supplement the wind turbine. Equipment such as parking meters or wireless Internet gateways may be powered
by a wind turbine that charges a small battery, replacing the need for a connection to the power grid. In locations near or around a group of high-rise buildings, wind shear generates areas of intense turbulence, especially at street-level. The risks associated with mechanical or catastrophic failure have thus plagued urban wind development in densely populated areas, rendering the costs of insuring urban wind systems prohibitive. Moreover, quantifying the amount of wind in urban areas has been difficult, as little is known about the actual wind resources of towns and cities. A new Carbon Trust study into the potential of small-scale wind energy has found that small wind turbines could provide up to 1.5 terawatt hours (TW·h) per year of electricity (0.4% of total UK electricity consumption), saving 0.6 million tonnes of carbon dioxide (Mt CO2) emission savings. This is based on the assumption that 10% of households would install turbines at costs competitive with grid electricity, around 12 pence (US 19 cents) a kW·h. Distributed generation from renewable resources is increasing as a consequence of the increased awareness of climate change. The electronic interfaces required to connect renewable generation units with the utility system can include additional functions, such as the active filtering to enhance the power quality.
Economics and feasibility
5 kilowatt Vertical axis wind turbine
Windmill with rotating sails
Relative cost of electricity by generation source Growth and cost trends Wind power has negligible fuel costs, but a high capital cost. The estimated average cost per unit incorporates the cost of construction of the turbine and transmission facilities, borrowed funds, return to investors (including cost of risk), estimated annual production, and other components, averaged over the projected useful life of the equipment, which may be in excess of twenty years. Energy cost estimates are highly dependent on these assumptions so published cost figures can differ substantially. A British Wind Energy Association report gives an average generation cost of onshore wind power of around 3.2
pence (between US 5 and 6 cents) per kW·h (2005). Cost per unit of energy produced was estimated in 2006 to be comparable to the cost of new generating capacity in the US for coal and natural gas: wind cost was estimated at $55.80 per MW·h, coal at $53.10/MW·h and natural gas at $52.50. Other sources in various studies have estimated wind to be more expensive than other sources. A 2009 study on wind power in Spain by the Universidad Rey Juan Carlos concluded that each installed MW of wind power destroyed 4.27 jobs, by raising energy costs and driving away electricity-intensive businesses. However, the presence of wind energy, even when subsidised, can reduce costs for consumers (€5 billion/yr in Germany) by reducing the marginal price by minimising the use of expensive 'peaker plants'. In 2004, wind energy cost a fifth of what it did in the 1980s, and some expected that downward trend to continue as larger multi-megawatt turbines were mass-produced. However, installed cost averaged €1,300 a kW in 2007, compared to €1,100 a kW in 2005. Not as many facilities can produce large modern turbines and their towers and foundations, so constraints develop in the supply of turbines resulting in higher costs. Global Wind Energy Council (GWEC) figures show that 2007 recorded an increase of installed capacity of 20 GW, taking the total installed wind energy capacity to 94 GW, up from 74 GW in 2006. Despite constraints facing supply chains for wind turbines, the annual market for wind continued to increase at an estimated rate of 37%, following 32% growth in 2006. In terms of economic value, the wind energy sector has become one of the important players in the energy markets, with the total value of new generating equipment installed in 2007 reaching €25 billion, or US$36 billion. Although the wind power industry will be impacted by the global financial crisis in 2009 and 2010, a BTM Consult five year forecast up to 2013 projects substantial growth. Over the past five years the average growth in new installations has been 27.6 percent each year. In the forecast to 2013 the expected average annual growth rate is 15.7 percent. More than 200 GW of new wind power capacity could come on line before the end of 2013. Wind power market penetration is expected to reach 3.35 percent by 2013 and 8 percent by 2018. Existing generation capacity represents sunk costs, and the decision to continue production will depend on marginal costs going forward, not estimated average costs at project inception. For example, the estimated cost of new wind power capacity may be lower than that for "new coal" (estimated average costs for new generation capacity) but higher than for "old coal" (marginal cost of production for existing capacity). Therefore, the choice to increase wind capacity will depend on factors including the profile of existing generation capacity.
Theoretical potential - World
Map of available wind power for the United States. Color codes indicate wind power density class. Wind power available in the atmosphere is much greater than current world energy consumption. The most comprehensive study as of 2005 found the potential of wind power on land and near-shore to be 72 TW, equivalent to 54,000 MToE (million tons of oil equivalent) per year, or over five times the world's current energy use in all forms. The potential takes into account only locations with mean annual wind speeds ≥ 6.9 m/s at 80 m. The study assumes six 1.5 megawatt, 77 m diameter turbines per square kilometer on roughly 13% of the total global land area (though that land would also be available for other compatible uses such as farming). The authors acknowledge that many practical barriers would need to be overcome to reach this theoretical capacity. The practical limit to exploitation of wind power will be set by economic and environmental factors, since the resource available is far larger than any practical means to develop it.
Theoretical potential - UK A recent estimate gives the total potential average output for UK for various depth and distance from the coast. The maximum case considered was beyond 200 km from shore and in depths of 100 – 700 m (necessitating floating wind turbines) and this gave an average resource of 2,000 GWe which is to be compared with the average UK demand of about 40 GWe.
Direct costs Many potential sites for wind farms are far from demand centres, requiring substantially more money to construct new transmission lines and substations. In some regions this is partly because frequent strong winds themselves have discouraged dense human settlement in especially windy areas. The wind which was historically a nuisance is now becoming a valuable resource, but it may be far from large populations which developed in areas more sheltered from wind. Since the primary cost of producing wind energy is construction and there are no fuel costs, the average cost of wind energy per unit of production depends on a few key assumptions, such as the cost of capital and years of assumed service. The marginal cost of wind energy once a plant is constructed is usually less than 1 cent per kW·h. Since the cost of capital plays a large part in projected cost, risk (as perceived by investors) will affect projected costs per unit of electricity. The commercial viability of wind power also depends on the price paid to power producers. Electricity prices are highly regulated worldwide, and in many locations may not reflect the full cost of production, let alone indirect subsidies or negative externalities. Customers may enter into long-term pricing contracts for wind to reduce the risk of future pricing changes, thereby ensuring more stable returns for projects at the development stage. These may take the form of standard offer contracts, whereby the system operator undertakes to purchase power from wind at a fixed price for a certain period (perhaps up to a limit); these prices may be different than purchase prices from other sources, and even incorporate an implicit subsidy. Where the price for electricity is based on market mechanisms, revenue for all producers per unit is higher when their production coincides with periods of higher prices. The profitability of wind farms will therefore be higher if their production schedule coincides with these periods. If wind represents a significant portion of supply, average revenue per unit of production may be lower as more expensive and less-efficient forms of generation, which typically set revenue levels, are displaced from economic dispatch. This may be of particular concern if the output of many wind plants in a market have strong temporal correlation. In economic terms, the marginal revenue of the wind sector as penetration increases may diminish.
Incentives
Some of the over 6,000 wind turbines at Altamont Pass, in California, United States. Developed during a period of tax incentives in the 1980s, this wind farm has more turbines than any other in the United States. Wind energy in many jurisdictions receives some financial or other support to encourage its development. Wind energy benefits from subsidies in many jurisdictions, either to increase its attractiveness, or to compensate for subsidies received by other forms of production which have significant negative externalities. In the United States, wind power receives a tax credit for each kW·h produced; at 1.9 cents per kW·h in 2006, the credit has a yearly inflationary adjustment. Another tax benefit is accelerated depreciation. Many American states also provide incentives, such as exemption from property tax, mandated purchases, and additional markets for "green credits". Countries such as Canada and Germany also provide incentives for wind turbine construction, such as tax credits or minimum purchase prices for wind generation, with assured grid access (sometimes referred to as feed-in tariffs). These feed-in tariffs are typically set well above average electricity prices. The Energy Improvement and Extension Act of 2008 contains extensions of credits for wind, including microturbines. Secondary market forces also provide incentives for businesses to use wind-generated power, even if there is a premium price for the electricity. For example, socially
responsible manufacturers pay utility companies a premium that goes to subsidize and build new wind power infrastructure. Companies use wind-generated power, and in return they can claim that they are making a powerful "green" effort. In the USA the organization Green-e monitors business compliance with these renewable energy credits.
Full costs and lobbying Commenting on the EU's 2020 renewable energy target, Helm (2009) is critical of how the costs of wind power are citied by lobbyists: For those with an economic interest in capturing as much of the climate-change pork barrel as possible, there are two ways of presenting the costs [of wind power] in a favourable light: first, define the cost base as narrowly as possible; and, second, assume that the costs will fall over time with R&D and large-scale deployment. And, for good measure, when considering the alternatives, go for a wider cost base (for example, focusing on the full fuel-cycle costs of nuclear and coal-mining for coal generation) and assume that these technologies are mature, and even that costs might rise (for example, invoking the peak oil hypothesis). A House of Lords Select Committee report (2008) on renewable energy in the UK says: We have a particular concern over the prospective role of wind generated and other intermittent sources of electricity in the UK, in the absence of a break-through in electricity storage technology or the integration of the UK grid with that of continental Europe. Wind generation offers the most readily available short-term enhancement in renewable electricity and its base cost is relatively cheap. Yet the evidence presented to us implies that the full costs of wind generation (allowing for intermittency, back-up conventional plant and grid connection), although declining over time, remain significantly higher than those of conventional or nuclear generation (even before allowing for support costs and the environmental impacts of wind farms). Furthermore, the evidence suggests that the capacity credit of wind power (its probable power output at the time of need) is very low; so it cannot be relied upon to meet peak demand. Thus wind generation needs to be viewed largely as additional capacity to that which will need to be provided, in any event, by more reliable means Helm (2009) says that wind's problem of intermittent supply will probably lead to another dash-for-gas or dash-for-coal in Europe, possibly with a negative impact on energy security. In the United States, the wind power industry has recently increased its lobbying efforts considerably, spending about $5 million in 2009 after years of relative obscurity in Washington.
Chapter-8 Biomass Gasification (Third-generation technology)
Gasification is a process that converts carbonaceous materials, such as coal, petroleum, biofuel, or biomass, into carbon monoxide and hydrogen by reacting the raw material at high temperatures with a controlled amount of oxygen and/or steam. The resulting gas mixture is called synthesis gas or syngas and is itself a fuel. Gasification is a method for extracting energy from many different types of organic materials. The advantage of gasification is that using the syngas is potentially more efficient than direct combustion of the original fuel because it can be combusted at higher temperatures or even in fuel cells, so that the thermodynamic upper limit to the efficiency defined by Carnot's rule is higher or not applicable. Syngas may be burned directly in internal combustion engines, used to produce methanol and hydrogen, or converted via the Fischer-Tropsch process into synthetic fuel. Gasification can also begin with materials that are not otherwise useful fuels, such as biomass or organic waste. In addition, the high-temperature combustion refines out corrosive ash elements such as chloride and potassium, allowing clean gas production from otherwise problematic fuels. Gasification of fossil fuels is currently widely used on industrial scales to generate electricity. However, almost any type of organic material can be used as the raw material for gasification, such as wood, biomass, or even plastic waste. Gasification relies on chemical processes at elevated temperatures >700°C, which distinguishes it from biological processes such as anaerobic digestion that produce biogas.
Chemistry In a gasifier, the carbonaceous material undergoes several different processes:
Pyrolysis of carbonaceous fuels
Gasification of char 1. The pyrolysis (or devolatilization) process occurs as the carbonaceous particle heats up. Volatiles are released and char is produced, resulting in up to 70% weight loss for coal. The process is dependent on the properties of the carbonaceous material and determines the structure and composition of the char, which will then undergo gasification reactions. 2. The combustion process occurs as the volatile products and some of the char reacts with oxygen to form carbon dioxide and carbon monoxide, which provides heat for the subsequent gasification reactions. Letting C represent a carboncontaining organic compound, the basic reaction here is 3. The gasification process occurs as the char reacts with carbon dioxide and steam to produce carbon monoxide and hydrogen, via the reaction 4. In addition, the reversible gas phase water gas shift reaction reaches equilibrium very fast at the temperatures in a gasifier. This balances the concentrations of carbon monoxide, steam, carbon dioxide and hydrogen. In essence, a limited amount of oxygen or air is introduced into the reactor to allow some of the organic material to be "burned" to produce carbon monoxide and energy, which drives a second reaction that converts further organic material to hydrogen and additional carbon dioxide. Further reactions occur when the formed carbon monoxide and residual water from the organic material react to form methane and excess carbon dioxide. This third reaction occurs more abundantly in reactors that increase the residence time of the reactive gases and organic materials, as well as heat and pressure. Catalysts are used in more sophisticated reactors to improve reaction rates, thus moving the system closer to the reaction equilibrium for a fixed residence time.
History
Adler Diplomat 3 with gas generator (1941) The Process of producing energy using the gasification method has been in use for more the 180 years. During that time coal and peat were used to power these plants. Initially developed to produce town gas for lighting & cooking in 1800s, this was replaced by electricity and natural gas, it was also used in blast furnaces but the bigger role was played in the production of synthetic chemicals where it has been in use since the 1920s. During both world wars especially the Second World War the need of gasification produced fuel reemerged due to the shortage of petroleum. Wood gas generators, called Gasogene or Gazogène, were used to power motor vehicles in Europe. By 1945 there were trucks, buses and agricultural machines that were powered by gasification. It is estimated that there were close to 9000,000 vehicles running on producer gas all over the world.
Gasification processes Four types of gasifier are currently available for commercial use: counter-current fixed bed, co-current fixed bed, fluidized bed and entrained flow.
The counter-current fixed bed ("up draft") gasifier consists of a fixed bed of carbonaceous fuel (e.g. coal or biomass) through which the "gasification agent" (steam, oxygen and/or air) flows in counter-current configuration. The ash is either removed dry or as a slag. The slagging gasifiers have a lower ratio of steam to carbon , achieving temperatures higher than the ash fusion temperature. The nature of the gasifier means that the fuel must have high mechanical strength and must ideally be non-caking so that it will form a permeable bed, although recent developments have reduced these restrictions to some extent. The throughput for this type of gasifier is relatively low. Thermal efficiency is high as the gas exit temperatures are relatively low. However, this means that tar and methane production is significant at typical operation temperatures, so product gas must be extensively cleaned before use. The tar can be recycled to the reactor. The co-current fixed bed ("down draft") gasifier is similar to the counter-current type, but the gasification agent gas flows in co-current configuration with the fuel (downwards, hence the name "down draft gasifier"). Heat needs to be added to the upper part of the bed, either by combusting small amounts of the fuel or from external heat sources. The produced gas leaves the gasifier at a high temperature, and most of this heat is often transferred to the gasification agent added in the top of the bed, resulting in an energy efficiency on level with the counter-current type. Since all tars must pass through a hot bed of char in this configuration, tar levels are much lower than the counter-current type. In the fluidized bed reactor, the fuel is fluidized in oxygen and steam or air. The ash is removed dry or as heavy agglomerates that defluidize. The temperatures are relatively low in dry ash gasifiers, so the fuel must be highly reactive; low-grade coals are particularly suitable. The agglomerating gasifiers have slightly higher temperatures, and are suitable for higher rank coals. Fuel throughput is higher than for the fixed bed, but not as high as for the entrained flow gasifier. The conversion efficiency can be rather low due to elutriation of carbonaceous material. Recycle or subsequent combustion of solids can be used to increase conversion. Fluidized bed gasifiers are most useful for fuels that form highly corrosive ash that would damage the walls of slagging gasifiers. Biomass fuels generally contain high levels of corrosive ash. In the entrained flow gasifier a dry pulverized solid, an atomized liquid fuel or a fuel slurry is gasified with oxygen (much less frequent: air) in co-current flow. The gasification reactions take place in a dense cloud of very fine particles. Most coals are suitable for this type of gasifier because of the high operating temperatures and because the coal particles are well separated from one another. The high temperatures and pressures also mean that a higher throughput can be achieved, however thermal efficiency is somewhat lower as the gas must be cooled before it can be cleaned with existing technology. The high temperatures also mean that tar and methane are not present in the product gas; however the oxygen requirement is higher than for the other types of gasifiers. All entrained flow gasifiers remove the major part of the ash as a slag as the operating temperature is well above the ash fusion temperature. A smaller fraction of the ash is produced either as a very fine dry fly ash or as a black colored fly ash slurry. Some fuels, in particular certain types of biomasses, can form slag that is corrosive for ceramic inner walls that serve to protect the gasifier outer wall. However some entrained
bed type of gasifiers do not possess a ceramic inner wall but have an inner water or steam cooled wall covered with partially solidified slag. These types of gasifiers do not suffer from corrosive slags. Some fuels have ashes with very high ash fusion temperatures. In this case mostly limestone is mixed with the fuel prior to gasification. Addition of a little limestone will usually suffice for the lowering the fusion temperatures. The fuel particles must be much smaller than for other types of gasifiers. This means the fuel must be pulverized, which requires somewhat more energy than for the other types of gasifiers. By far the most energy consumption related to entrained bed gasification is not the milling of the fuel but the production of oxygen used for the gasification.
Current applications In small business and building applications, where the wood source is sustainable, 2501000 kWe and new zero carbon biomass gasification plants have been installed in Europe that produce tar free syngas from wood and burn it in a reciprocation engines connected to a generator with heat recovery. This type plant is often referred to as a wood biomass CHP unit but is a plant of seven different processes: biomass processing, fuel delivery, gasification, gas cleaning, waste disposal, electricity generation and heat recovery. Industrial-scale gasification is currently mostly used to produce electricity from fossil fuels such as coal, where the syngas is burned in a gas turbine. Gasification is also used industrially in the production of electricity, ammonia and liquid fuels (oil) using Integrated Gasification Combined Cycles (IGCC), with the possibility of producing methane and hydrogen for fuel cells. IGCC is also a more efficient method of CO2 capture as compared to conventional technologies. IGCC demonstration plants have been operating since the early 1970s and some of the plants constructed in the 1990s are now entering commercial service. Gasification technologies have been developed in recent years that use plastic-rich waste as a feed. Syngas can be used for heat production and for generation of mechanical and electrical power. Like other gaseous fuels, producer gas gives greater control over power levels when compared to solid fuels, leading to more efficient and cleaner operation. Gasifiers offer a flexible option for thermal applications, as they can be retrofitted into existing gas fueled devices such as ovens, furnaces, boilers, etc., where syngas may replace fossil fuels. Heating values of syngas are generally around 4-10 MJ/m3. Diesel engines can be operated on dual fuel mode using producer gas. Diesel substitution of over 80% at high loads and 70-80% under normal load variations can easily be achieved. Spark ignition engines and SOFC fuel cells can operate on 100% gasification gas. Mechanical energy from the engines may be used for e.g. driving water pumps for irrigation or for coupling with an alternator for electrical power generation.
Small-scale rural biomass gasifiers have been applied in India to a large extent, especially in the state of Tamil-Nadu in South India. Most of the applications are 9 kWe systems used for water pumping and street lighting operated by the local panchayat government. Although technically applicable the systems face political, financial and maintenance problems. Most of the systems are no longer running after 1–3 years. While small scale gasifiers have existed for well over 100 years, there have been few sources to obtain a ready to use machine. Small scale devices are typically DIY projects. However, currently in the US several companies offer gasifiers to operate small engines.
Potential for renewable energy
Gasification plant Güssing, Austria (2006) In principle, gasification can proceed from just about any organic material, including biomass and plastic waste. The resulting syngas can be combusted. Alternatively, if the
syngas is clean enough, it may be used for power production in gas engines, gas turbines or even fuel cells, or converted efficiently to dimethyl ether (DME) by methanol dehydration, methane via the Sabatier reaction, or diesel-like synthetic fuel via the Fischer-Tropsch process. In many gasification processes most of the inorganic components of the input material, such as metals and minerals, are retained in the ash. In some gasification processes (slagging gasification) this ash has the form of a glassy solid with low leaching properties, but the net power production in slagging gasification is low (sometimes negative) and costs are higher. Regardless of the final fuel form, gasification itself and subsequent processing neither directly emits nor traps greenhouse gasses such as carbon dioxide. Power consumption in the gasification and syngas conversion processes may be significant though, and may indirectly cause CO2 emissions; in slagging and plasma gasification, the electricity consumption may even exceed any power production from the syngas. Combustion of syngas or derived fuels emits exactly the same amount of carbon dioxide as would have been emitted from direct combustion of the initial fuel. Biomass gasification and combustion could play a significant role in a renewable energy economy, because biomass production removes the same amount of CO2 from the atmosphere as is emitted from gasification and combustion. While other biofuel technologies such as biogas and biodiesel are carbon neutral, gasification in principle may run on a wider variety of input materials and can be used to produce a wider variety of output fuels. There is at present very little industrial scale biomass gasification being done. Examples of demonstration projects include those of the Renewable Energy Network Austria, including a plant using dual fluidized bed gasification that has supplied the town of Güssing with 2 MW of electricity and 4 MW of heat, generated from wood chips, since 2003.
Waste disposal
HTCW reactor, one of several proposed waste gasification processes. According to the sales and sales management consultants KBI Group a pilot plant in Arnstadt implementing this process has completed initial tests. Waste gasification has several principal advantages over incineration: • •
The necessary extensive flue gas cleaning may be performed on the syngas instead of the much larger volume of flue gas after combustion. Electric power may be generated in engines and gas turbines, which are much cheaper and more efficient than the steam cycle used in incineration. Even fuel cells may potentially be used, but these have rather severe requirements regarding the purity of the gas.
• •
Chemical processing of the syngas may produce other synthetic fuels instead of electricity. Some gasification processes treat ash containing heavy metals at very high temperatures so that it is released in a glassy and chemically stable form.
A major challenge for waste gasification technologies is to reach an acceptable (positive) gross electric efficiency. The high efficiency of converting syngas to electric power is counteracted by significant power consumption in the waste preprocessing, the consumption of large amounts of pure oxygen (which is often used as gasification agent), and gas cleaning. Another challenge becoming apparent when implementing the processes in real life is to obtain long service intervals in the plants, so that it is not necessary to close down the plant every few months for cleaning the reactor. Several waste gasification processes have been proposed, but few have yet been built and tested, and only a handful have been implemented as plants processing real waste, and always in combination with fossil fuels. One plant (in Chiba, Japan using the Thermoselect process) has been processing industrial waste since year 2000, but has not yet documented positive net energy production from the process. Ze-gen is operating a waste gasification demonstration facility in New Bedford, Massachusetts. The facility was designed to demonstrate gasification of specific nonMSW waste streams using liquid metal gasification
Chapter-9 Enhanced Geothermal System (ThirdGeneration Technology)
Enhanced geothermal system 1:Reservoir 2:Pump house 3:Heat exchanger 4:Turbine hall 5:Production well 6:Injection well 7:Hot water to district heating 8:Porous sediments 9:Observation well 10:Crystalline bedrock Enhanced Geothermal Systems (EGS) are a new type of geothermal power technologies that do not require natural convective hydrothermal resources. Until recently, geothermal power systems have only exploited resources where naturally occurring water and rock porosity is sufficient to carry heat to the surface. However, the vast majority of geothermal energy within drilling reach is in dry and non-porous rock. EGS technologies "enhance" and/or create geothermal resources in this hot dry rock (HDR) through hydraulic stimulation. When natural cracks and pores will not allow for economic flow rates, the permeability can be enhanced by pumping high pressure cold water down an injection well into the rock. The injection increases the fluid pressure in the naturally fractured granite which mobilizes shear events, enhancing the permeability of the fracture system. Water travels through fractures in the rock, capturing the heat of the rock until it is forced out of a second borehole as very hot water, which is converted into electricity using either a steam turbine or a binary power plant system. All of the water, now cooled, is injected back into the ground to heat up again in a closed loop. EGS / HDR technologies, like hydrothermal geothermal, are expected to be baseload resources which produce power 24 hours a day like a fossil plant. Distinct from hydrothermal, HDR / EGS may be feasible anywhere in the world, depending on the economic limits of drill depth. Good locations are over deep granite covered by a thick (3–5 km) layer of insulating sediments which slow heat loss. HDR wells are expected to have a useful life of 20 to 30 years before the outflow temperature drops about 10 degrees Celsius and the well becomes uneconomic. If left for 50 to 300 years the temperature will recover. There are HDR and EGS systems currently being developed and tested in France, Australia, Japan, Germany, the U.S. and Switzerland. The largest EGS project in the world is a 25 megawatt demonstration plant currently being developed in the Cooper Basin, Australia. The Cooper Basin has the potential to generate 5,000–10,000 MW.
EGS industry Commercial projects are currently either operational or under development in Australia, the United States, and Germany. The largest project in the world is being developed in Australia's Cooper Basin by Geodynamics. The Cooper Basin project has the potential to develop 5–10 GW. Australia now has 33 firms either exploring for, drilling, or developing EGS projects. Australia's industry has been greatly aided by a national Renewable Portfolio Standard of 25% renewables by 2025, a vibrant Green Energy Credit market, and supportive R&D collaboration between government, academia, and industry.
Germany's 23 cent/kWh Feed-In Tariff (FIT) for geothermal energy has led to a surge in geothermal development, despite Germany's relatively poor geothermal resource. The Landau partial EGS project is profitable today under the FIT. The AltaRock Energy effort is a demonstration project being conducted to prove out the company's proprietary technology at the site of an existing geothermal project owned and operated by NCPA in The Geysers, and does not include power generation. However, any steam produced by the project will be supplied to NCPA's flash turbines under a longterm contract.
Project
Type
Soultz
R&D
Desert Peak
R&D
Landau Commercial Paralana (Phase Commercial 1) Cooper Commercial Basin
Current EGS projects Plant Depth Country Size (MW) Developer Status Type (km) France 1.5 Binary 4.2 ENGINE Operational (EU) United DOE, Ormat, 11–50 Binary Development States GeothermEx Germany 3 Binary 3.3 ? Operational (EU) Australia 7–30
Binary 4.1
Petratherm
Australia 250–500
Kalina 4.3
Geodynamics Drilling
AltaRock 3.5 – Energy, 3.8 NCPA AltaRock Energy, United (Unknown) Demonstration Davenport States Power 1.0 – R&D Japan (Unknown) 1.1 Geothermal United Commercial 10 MW Binary 4.5 Engineering Kingdom Ltd United EGS Energy Commercial 3 MW Binary 3–4 Kingdom Ltd.
The United Demonstration Geysers States Bend, Oregon Ogachi United Downs, Redruth Eden Project
(Unknown) Flash
Drilling
Canceled (Jan 2010) Permitting (Mar 2010) CO2 experiments Fundraising Fundraising
Research and development Australia The Australian government has provided research funding for the development of Hot Dry Rock technology. On 30 May 2007, then Australian opposition environmental spokesperson and current Minister for the Environment, Heritage and the Arts Peter Garrett announced that if elected at the 2007 Australian Federal Election, the Australian Labor Party would use taxpayers money to subsidise putting the necessary drilling rigs in place. In an interview, he promised: "There are some technical difficulties and challenges there, but those people who are keen on getting Australia into geothermal say we've got this great access to resource and one of the things, interestingly, that's held them back is not having the capacity the put the drilling plants in place. And so what we intend this $50 million to go towards is to provide a one for one dollars. Match $1 from us, $1 from the industry so that they can get these drilling rigs on to site and really get the best sites identified and get the industry going."
European Union The EU's EGS R&D project at Soultz-sous-Forêts, France, has recently connected its 1.5 MW demonstration plant to the grid. The Soultz project has explored the connection of multiple stimulated zones and the performance of triplet well configurations (1 injector/2 producers). Portugal – Portuguese government has awarded, December 2008, an exclusive license to Geovita Ltd, to prospect and explore geothermal energy in one of the best areas in continental Portugal. An area of about 500 square kilometers that is being studied together by Geovita and Coimbra's University — Science and Technology Faculty — Earth Sciences Department, and foresees the installation of an Enhanced Geothermal System (EGS). Induced seismicity in Basel led to the cancellation of the EGS project.
United Kingdom Cornwall is set to host a 3MW demonstration project, based at the Eden Project, that could pave the way for a series of 50MW commercial-scale geothermal power stations in suitable areas across the country. A commercial-scale project near Redruth is also planned. The plant, which has been granted planning permission, would generate 10MW of electricity, and 55MW of thermal energy, and is scheduled to become operational in 2013–2014.
United States
Early Days—Fenton Hill The United States pioneered the first EGS effort—then termed Hot Dry Rock—at Fenton Hill, New Mexico with a project run by the federal Los Alamos Laboratory. It was the first attempt anywhere to make a deep, full-scale HDR reservoir, and efforts there spanned 1974 through 1992, in two phases. Ultimately, the project was unable to generate net energy, and the project was terminated.
Working at the Edges—Using EGS Technology to Improve Hydrothermal Resources EGS funding languished for the next few years, and by the next decade, U.S. efforts focused on the less ambitious goal of improving the productivity of existing hydrothermal resources. According to the Fiscal Year 2004 Budget Request to Congress from DOE's Office of Energy Efficiency and Renewable Energy, EGS are engineered reservoirs that have been created to extract heat from economically unproductive geothermal resources. EGS technology includes those methods and equipment that enhance the removal of energy from a resource by increasing the productivity of the reservoir. Better productivity may result from improving the reservoir’s natural permeability and/or providing additional fluids to transport heat. In Fiscal Year 2002, this vision translated into completing "preliminary designs for five competitively selected projects employing EGS technology," and the selection of one project for "full-scale development" at the Coso Hot Springs geothermal field at the U.S. Naval Weapons Air Station in China Lake, Calif., and two additional projects for "preliminary analysis from a new solicitation" at Desert Peak in Nevada and Glass Mountain in California. Funding for this effort totaled $1.5 million. In Fiscal Year 2003, $3.5 million was appropriated to launch the Coso project, with the aim of improving the permeability of an existing poorly performing well, and to complete the conceptual design and feasibility studies at the Desert Peak and Glass Mountain sites. The Fiscal Year 2004 request for $6 million was to "[s]tep up work on EGS cost-shared projects' at the three sites, to include "drilling and reservoir stimulation experiments" at one and drilling a production well at another. The U.S. Department of Energy USDOE issued two Funding Opportunity Announcements (FOAs) on March 4, 2009 for enhanced geothermal systems (EGS). Together, the two FOAs offer up to $84 million over six years, including $20 million in fiscal year 2009 funding, although future funding is subject to congressional appropriations.
The DOE followed up with another FOA on March 27, 2009, of stimulus funding from the American Reinvestment and Recovery Act for $350 million, including $80 million aimed specifically at EGS proejcts,
Induced seismicity Some induced seismicity is inevitable and, indeed, expected in EGS, which involves pumping fluids at pressure to enhance or create permeability through the use of hydraulic fracturing techniques. Depending on the rock properties, and on injection pressures and fluid volume, the reservoir rock may respond with tensile failure, as is common in the oil and gas industry, or with shear failure of the rock's existing joint set, as is thought to be the main mechanism of reservoir growth in EGS efforts. Seismicity events at the Geysers geothermal field in California have been strongly correlated with injection data. In several cases, significant events have occurred including a magnitude 7.2 event at Baja California in Mexico. The case of induced seismicity in Basel bears special mention because it led the city (which is a partner) to suspend the project and conduct a seismic hazard evaluation, which resulted in the cancellation of the project in December 2009.
CO2 EGS The recently established Center for Geothermal Energy Excellence at the University of Queensland, has been awarded $18.3 million (AUS) for EGS research, a large portion of which will be used to develop CO2 EGS technologies. Research conducted at Los Alamos National Laboratories and Lawrence Berkeley National Laboratories examined the use of supercritical CO2, instead of water, as the geothermal working fluid with favorable results. CO2 has numerous advantages for EGS: 1. 2. 3. 4.
Greater power output Minimized parasitic losses from pumping and cooling Carbon sequestration Minimized water use
EGS potential in the United States
Geothermal power technologies. A 2006 report by MIT, and funded by the U.S. Department of Energy, conducted the most comprehensive analysis to date on the potential and technical status of EGS. The 18-member panel, chaired by Professor Jefferson Tester of MIT, reached several significant conclusions: 1. Resource Size: The report calculated the United States total EGS resources from 3–10 km of depth to be over 13,000 zettajoules, of which over 200 ZJ would be extractable, with the potential to increase this to over 2,000 ZJ with technology improvements — sufficient to provide all the world's current energy needs for several millennia. The report found that total geothermal resources, including hydrothermal and geo-pressured resources, to equal 14,000 ZJ — or roughly 140,000 times the total U.S. annual primary energy use in 2005. 2. Development Potential: With a modest R&D investment of $1 billion over 15 years (or the cost of one coal power plant), the report estimated that 100 GWe (gigawatts of electricity) or more could be installed by 2050 in the United States. The report further found that the "recoverable" resource (that accessible with today's technology) to be between 1.2–12.2 TW for the conservative and moderate recovery scenarios respectively. 3. Cost: The report found that EGS could be capable of producing electricity for as low as 3.9 cents/kWh. EGS costs were found to be sensitive to four main factors:
1) Temperature of the resource, 2) Fluid flow through the system measured in liters/second, 3) Drilling Costs, and 4) Power conversion efficiency.