Analytical Spectroscopy Library 10
Separation, Preconcentration and Spectrophotometry in Inorganic Analysis
Analytical Spectroscopy Library A Series of Books Devoted to the Application of Spectroscopic Techniques to Chemical Analysis Volume 1 NMR for Liquid Fossil Fuels, by L. Petrakis and D. Allen Volume 2 Advances in Standards and Methodology in Spectrophotometry, edited by C. Burgess and K.D. Mielenz Volume 3 Introduction to Inductively Coupled Plasma Atomic Emission Spectrometry, by G.L. Moore Volume 4 Sample Introduction in Atomic Spectroscopy, edited by J. Sneddon Volume 5 Atomic Absorption Spectrometry. Theory, Design and Applications, edited by S.J. Haswell Volume 6 Spectrophotometry, Luminescence and Colour; Science and Compliance, edited by C. Burgess and D.G. Jones Volume 7 Applications of Synchrotron Radiation to Materials Analysis, edited by H. Saisho and Y. Gohshi Volume 8 Methods for Structure Elucidation by High-Resolution NMR, edited by Gy. Batta, K.E. K6ver and Cs. Sz~.ntay, Jr. Volume 9 Flow Analysis with Atomic Spectrometric Detectors, edited by A. Sanz-Medel Volume 10 Separation, Preconcentration and Spectrophotometry in Inorganic Analysis, by Z. Marczenko and M. Balcerzak
Analytical S p e c t r o s c o p y L i b r a r y -
10
Separation, Preconcentration and Spectrophotometry in Inorganic Analysis by Zygmunt Marczenko and Maria Balcerzak
Department of Analytical Chemistry, Warsaw University of Technology, Naokowskiego 3, 00-664 Warsaw, Poland Translated by Eugeniusz Kr
2000 ELSEVIER Amsterdam
- Lausanne - New York - Oxford - Shannon - Tokyo
This work is an enlarged translation of Spektrofotometryczne metody w analizie nieorganicznej by Zygmunt Marczenko and Maria Balcerzak 9 Wydawnictwo Naukowe PWN, SA, Warszawa, 1998 Published by arrangement with Polish Scientific Publishers PWN 9 2000 Elsevier Science B. V. for the English edition only ELSEVIER SCIENCE B.V. Sara Burgerhartstraat 25 P.O. Box 211, 1000 AE Amsterdam, The Netherlands
This work is protected under copyright by Elsevier Science, and the following terms and conditions apply to its use: Photocopying Single photocopies of single chapters may be made for personal use as allowed by national copyright laws. Permission of the Publisher and payment of a fee is required for all other photocopying, including multiple or systematic copying, copying for advertising or promotional purposes, resale, and all forms of document delivery. Special rates are available for educational institutions that wish to make photocopies for non-profit educational classroom use. Permissions may be sought directly from Elsevier Science Global Rights Department, P 9 Box 800, Oxford OX5 1DX, UK; phone: (+44) 1865 843830, fax: (+44) 1865 853333, e-mail:
[email protected]. You may also contact Global Rights directly through Elsevier's home page (http://www.elsevier.nl), by selecting 'Obtaining Permissions'. In the USA, users may clear permissions and make payments through the Copyright Clearance Center, Inc., 222 Rosewood Drive, Danvers, MA 01923, USA; phone: (978) 7508400, fax: (978) 7504744, and in the UK through the Copyright Licensing Agency Rapid Clearance Service (CLARCS), 90 Tottenham Court Road, London W1P 0LP, UK; phone: (+44) 207 631 5555; fax: (+44) 207 631 5500. Other countries may have a local reprographic rights agency for payments. Derivative Works Tables of contents may be reproduced for internal circulation, but permission of Elsevier Science is required for external resale or distribution of such material. Permission of the Publisher is required for all other derivative works, including compilations and translations. Electronic Storage or Usage Permission of the Publisher is required to store or use electronically any material contained in this work, including any chapter or part of a chapter. Except as outlined above, no part of this work may be reproduced, stored in a retrieval system or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without prior written permission of the Publisher. Address permissions requests to: Elsevier Science Global Rights Department, at the mail, fax and e-mail addresses noted above. Notice No responsibility is assumed by the Publisher for any injury and/or damage to persons or property as a matter of products liability, negligence or otherwise, or from any use or operation of any methods, products, instructions or ideas contained in the material herein. Because of rapid advances in the medical sciences, in particular, independent verification of diagnoses and drug dosages should be made.
First edition 2000 Library of Congress Cataloging in Publication Data A catalog record from the Library of Congress has been applied for.
ISBN: ISSN:
0 444 50524 5 0926 4345
The paper used in this publication meets the requirements of ANSI/NISO Z39.48-1992 (Permanence of Paper). Printed in The Netherlands.
Contents Preface ...................................................................................................................................... Abbreviations ...........................................................................................................................
Part I. Chapter Chapter Chapter Chapter
3 4
General 1. 2. 3. 4.
Separation and preconcentration of elements ..................................................... 5 Principles of spectrophotometry ........................................................................ 26 Spectrophotometric methods ............................................................................. 39 Spectrophotometric reagents ............................................................................. 53
Part II.
Determination of Elements
Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter Chapter
Alkali metals ..................................................................................................... 77 Aluminium ........................................................................................................ 83 Antimony .......................................................................................................... 92 Arsenic .............................................................................................................. 99 Beryllium ........................................................................................................ 107 Bismuth ......................................................................................................... 113 Boron .............................................................................................................. 121 Bromine .......................................................................................................... 129 C a d m i u m ........................................................................................................ 133 Calcium .......................................................................................................... 140 Carbon ............................................................................................................ 147 Chlorine .......................................................................................................... 152 C h r o m i u m ....................................................................................................... 159 Cobalt ............................................................................................................. 167 Copper ............................................................................................................ 177 Fluorine .......................................................................................................... 189 Gallium ........................................................................................................... 198 G e r m a n i u m ..................................................................................................... 204 Gold ................................................................................................................ 210 Indium ............................................................................................................ 216 Iodine .............................................................................................................. 222 Iron ................................................................................................................. 226 Lead ................................................................................................................ 238 M a g n e s i u m ..................................................................................................... 247 Manganese ...................................................................................................... 253
5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29.
Chapter 30. Mercury ..........................................................................................................262 Chapter 31. M o l y b d e n u m and tungsten ............................................................................. 270 Chapter 32. Nickel ............................................................................................................. 284 Chapter 33. N i ob i u m and tantalum .................................................................................... 293 Chapter 34. Nitrogen ..........................................................................................................304 Chapter 35. Oxygen ...........................................................................................................315 Chapter 36. Palladium ........................................................................................................318 Chapter 37. Phosphorus .....................................................................................................326 Chapter 38. Platinum ..........................................................................................................334 Chapter 39. Rare-earth elements ........................................................................................341 Chapter 40. R h e n i u m .........................................................................................................350 Chapter 41. R h o d i u m and iridium ......................................................................................357 Chapter 42. Ruthenium and o s m i u m ..................................................................................365 Chapter 43. Scandium ........................................................................................................375 Chapter 44. Selenium .........................................................................................................379 Chapter 45. Silicon .............................................................................................................385 Chapter 46. Silver ..............................................................................................................392 Chapter 47. Strontium and barium .....................................................................................399 Chapter 48. Sulphur ...........................................................................................................403 Chapter 49. Tellurium ........................................................................................................412 Chapter 50. Thallium .........................................................................................................418 Chapter 51. Thorium ..........................................................................................................424 Chapter 52. Tin ..................................................................................................................431 Chapter 53. Titanium .........................................................................................................438 Chapter 54. Uranium ..........................................................................................................446 Chapter 55. V a n a d i u m .......................................................................................................456 Chapter 56. Zinc .................................................................................................................466 Chapter 57. Zirconium and hafnium ..................................................................................474 A p p e n d i x ..............................................................................................................................483 Index .....................................................................................................................................514
Preface Spectrophotometry enables to determine, with a good precision and sensitivity, almost all the elements present in small and trace quantities in any materials. The method is particularly useful in the determination of non-metals. In the book, much attention has been paid to separation and preconcentration methods, since they play an essential role in increasing the selectivity and sensitivity of spectrophotometric methods. The separation and preconcentration methods have been utilised also in other determination techniques. Modern spectrophotometers, supplied with data-processing capabilities, enable the treatment of absorption spectra in the derivative spectrophotometry. The spectrophotometric methods can be easily automatized, e.g. in the flow injection analysis. Chapters 1-4 provide the characteristics of the separation and preconcentration methods: solvent extraction, flotation, coprecipitation with collectors, volatilization, ion exchange etc. These chapters deal also with the fundamentals of spectrophotometry, spectrophotometric methods of analysis, and most important chromogenic reagents. Chapters 5-57 have been devoted to individual elements or groups of related elements. In the monograph much attention has been paid to the application of the methods in analytical practice. The references, listed at the end of each chapter and critically selected, cover the works published until the end of 1999. The book has been designed for analytical chemists dealing with environment protection, geology, biology, many branches of industry, etc. It will also be a useful guide for students interested in becoming specialists in analytical chemistry. Zygmunt Marczenko and Maria Balcerzak
Abbreviations
BPHA 5-Br-PADAP CAS CP CTA DAM DAPM DDTC DIPE DMF ECR EDTA g
FIA HzDm H2Dz HTTA MIBK NTA oxine PAN phen ppb ppm REE SPADNS sp. abs., a TAN TAR TBP TEA TOA TOPO TPTZ
N-benzoyl-N-phenylhydroxylamine 2-(5-Br-2-pyridylazo)-5-diethylaminophenol Chrome Azurol S cetylpyridinium ion (or salt) cetyltrimethylammonium ion (or salt) diantipyrylmethane diantipyrylpropylmethane diethyldithiocarbamate di-isopropyl ether dimethylformamide Eriochrome Cyanine R ethylenediaminetetraacetic acid (or disodium salt) molar absorptivity flow-injection analysis dimethylglyoxime dithizone, diphenylthiocarbazone thenoyltrifluoroacetone wavelength methyl isobutyl ketone nitrilotriacetic acid 8-hydroxyquinoline, 8-quinolinol 1-(2-pyridylazo)resorcinol 1,10-phenanthroline parts per billion parts per million rare-earth elements 2-(4-sulphophenylazo)chromotropic acid specific absorptivity 1-(2- thiaz olyl azo)- 2-naphthol 4-(2-thiazolylazo)resorcinol tri-n-butyl phosphate triethanolamine tri-n-octylamine tri-n-octylphosphine oxide 2,4,6-tri(2'-pyridyl)-s-triazine
Chapter 1. Separation and preconcentration of elements The spectrophotometric determination of elements is usually preceded by their separation from major components (matrix) and from interfering elements, the effects of which cannot be eliminated by other methods such as masking or change of pH of the medium. In the trace analysis of high-purity materials, separation from the matrix involves simultaneous concentration of the trace components. General methods of preconcentrating and separating elements have been outlined in several monographs and reviews [1-4]. The present Section provides a discussion of the following separation and preconcentration methods: solvent extraction, precipitation and co-precipitation with collectors, volatilization, and methods based on the use of ion-exchangers and other sorbents. These methods are used not only with spectrophotometry, but also in conjunction with other methods of determination.
1.1. Solvent extraction 1.1.1. Introduction The extraction process and extractive methods for separation and preconcentration of elements are described in several monographs and reviews [5,6]. Solvent extraction separation is based on differences in the solubilities of elements and their compounds between two immiscible liquid phases. Usually, the initial phase is an aqueous solution and the second phase is an organic solvent, immiscible with water. Some properties of the more common organic solvents are listed in Table 1.1. The ion to be extracted into the non-aqueous phase should first be transformed into an uncharged species. Stripping ("re-extraction", "back-extraction", or "scrubbing") involves bringing the element from the organic extract back into the aqueous phase. The extraction efficiency, i.e., the degree of transfer of the species from the aqueous to the organic phase, is defined in terms of the distribution- (or extraction-) coefficient, (D). The quantity D is the ratio of total concentration (i.e., the concentration of all the existing forms) of the element in the organic phase (Ec0) to the total concentration in the aqueous phase (ECw) in the aqueous phase, at equilibrium
ZC o
The extraction efficiency (%E) is also expressed as the extraction percent %E =
100D
D+(Vw/Vo) where D is the distribution coefficient, and Vw and Vo are the volumes of the aqueous and the organic phases, respectively.
6
1. Separation and preconcentration of elements
When the distribution coefficient of a given element in a specified system is large (e.g., 1,000, i.e., log D = 3), a single extraction will suffice. In most extraction systems the partition coefficients change as the concentration of the substance extracted changes; in most cases they decrease with decreasing concentration [7]. T a b l e 1.1. Physical properties of s o m e organic s o l v e n t s Solvent Acetate, n-amyl n-butyl ethyl Acetone Alcohol, n-amyl n-butyl ethyl methyl Benzene Carbon tetrachloride Chloroform Cyclohexane o-Dichlorobenzene 1,2-Dichloroethane Dioxan Ethers, di(2-chloroethyl) Diethyl di-isopropyl (DIPE) Hexane Methyl isobutyl ketone (MIBK) Methylene chloride (dichloromethane) Mesityl oxide Nitrobenzene 1-Octanol Tetrachloroethylene Toluene Trichloroethylene misc. - completely miscible
Density 9/ml 0.87 0.88 0.90 0.89 0.81 0.81 0.79 0.80 0.89 1.59 1.50 0.78 1.30 1.26 1.03 1.22 0.72 0.73 0.66
Boiling point oC 149 126 77 57 138 118 78 65 80 77 61 81 180 83 101 178 35 68 69
Dielectric constant 4.8 5.0 6.0 20.7 13.8 17.1 24.3 32.6 2.3 2.2 4.8 2.0 9.9 10.4 2.2 23.0 4.3 3.9 1.9
Solubility in water % 0.2 0.5 8.6 misc. 2.2 7.9 misc. misc. 0.2 0.1 1.0 0.01 0.01 0.9 misc. 1.0 7.4 0.7 0.02
0.80
116
13.1
2.0
1.34 0.85 1.21 0.83 1.63 0.87 1.46
40 129 211 194 121 111 87
9.1 15.6 34.8 10.3 2.3 2.4 3.4
2.0 3.2 0.2 0.05 0.02 0.05 0.1
Shaking the phases in a separating funnel during the extraction or re-extraction must be continued until equilibrium is attained. The time required for the system to reach equilibrium varies from seconds to several minutes, depending on the kinetics of the process [8-10]. When the shaking time recommended is more than two minutes, it is advisable to use a mechanical shaker. Extraction is equally useful in the preconcentration and separation of small amounts of elements, and in the separation of macrocomponents from traces. Extraction methods generally require less time than precipitation methods. The former give also "purer" separation of elements owing to the small area of phase contact. Co-extraction occurring in some cases [ 11 ] has not been widely used in extraction separations.
1.1. Solvent extraction
7
1.1.2. Extraction systems Extraction systems may be divided into two classes: (1) uncharged covalent species (simple molecules and chelates), and (2) ion associates (ion pairs). Simple molecules (e.g., I2, HgC12, AsC13, BiI3, GeC14, OsO4) are extracted with nonpolar solvents such as benzene, CHC13, CC14. The extraction of this type of compound is comparatively selective and is widely applied in separation of some elements [5,12,13]. Inner chelates (uncharged chelates) are formed when metal ions react with bifunctional ligands, such as dithizone (formula 1.1), 8-hydroxyquinoline [14] (formula 1.2), dithiocarbamates (formulae 1.3 and 1.4), ethyl xanthates [15,16], cupferron (formula 1.5), BPHA (N-benzoyl-N-phenylhydroxylamine) [17,18], acetylacetone (formula 1.6) and thenoyltrifluoroacetone (HTTA) (formula 1.7) [19,20].
S=c/NH-NH-~
--N------NH~
Hs_C//
\"-J/
II
I
(1.1) CzH5
.,~S
CzH/
~S-Na ยง
\N__C// (].3)
(1.2)
O"NI'I~' N/~N~O
(1.5)
CzHs_ S "X~N--ICI- S-[NH2(CzHs)z]+ CzH/ (1.4)
H3C~ HC~,C---OH
iH
H3C/C~''~-'O (1.6)
(1.7)
Inner chelates are extracted with non-polar solvents (mostly with CHC13 and CC14). Synergism [21,22] is important in the extraction of some chelates. Some inner chelates were extracted into chloroform solutions of diantipyrylmethane (DAM) (formula 1.8) [23]. The effects of salting-out agent, solvent, and temperature on the
8
1. Separation and preconcentration of elements
H3C----C~C--CH2-- C ~ C - - C H 3 I
.
I
t
H3C~N~N~C---'~ 0 0~----C~ 7N---'.-CH3
(1.8)
lC~Hs
i
C6Hs
extraction have been discussed [20]. Selectivity can be increased by using the exchange technique, in which a less-stable metal chelate is the source of the chelating agent [24]. The extraction of chelates is usually applied to preconcentration and separation of small amounts of metals. Owing to their low solubility in organic solvents, most chelates can not be used for the extraction of macrocomponents. Cupferronates and acetylacetonates are exceptions. Chelates of metal ions with alkyl- and arylphosphoric and thiophosphoric acids can be extracted into chloroform and other solvents [25,26]. Such systems enable one to separate, by means of extraction procedures, many metals from strongly acid solutions. Examples of such reagents are di-(2-ethylhexyl)phosphoric acid (HDEHP) and di-n-butyldithiophosphoric acid (formulae 1.9 and 1.10). HDEHP is a viscous liquid (density 0.98), slightly soluble in water, but readily soluble in benzene, hexane, and MIBK.
~zHs
CI.Hg~CH~CHz~O~
~,0
P, C~Hg~CH~CHz~O ~ ~OH ~zHs
(1.9)
(1.10)
Ion associates (ion-pairs) are formed by the electrostatic attraction of oppositelycharged ions which have, in general, high molecular weight. Ion-associates may be divided into several groups. Halometallic acids (e.g., HFeC14, HSbC16, HAuBr4, H2CdI4) are formed in reactions of multivalent metal ions with hydrohalic acids. These compounds are extractable from acid solutions containing high concentrations of halide ions by oxygen-containing solvents such as ethers, higher alcohols, ketones, and esters [27]. The extraction of halometallic acids is made possible by solvation of the protons by the solvent molecules, and often secondary solvation of the ion-pair formed. Since the solvent molecule co-ordinates through its oxygen atom, such systems are sometimes called oxonium extraction systems. Extractions from chloride- [28,29], bromide- [30], iodide- [29,31,32], fluoride- [33], and thiocyanate- [34] systems have been discussed.
Heteropoly acids [oxygen compounds of Mo(VI), W(VI), Si, P(V), As(V), Ge, and other elements] and their reduction products (molybdenum blues) are extracted into oxygencontaining solvents by a mechanism similar to that above. Another group of ion-association systems is represented by solvated salts (usually nitrates, but also halides and sulphates). Solutions (1-50%) of tri-n-butyl phosphate (TBP, formula 1.11) in hexane, CC14, and solutions (1-20 %) of tri-n-octylphosphine oxide (TOPO, formula 1.12) in cyclohexane are most often used as the extractants. Solvation with TBP or TOPO (through the strongly basic oxygen atom of the phosphoryl group) enables metal salts,
1.1. Solventextraction
9
such as UO2(NO3)2"2TBP, Th(NO3)4"2TBP, Zr(NO3)4"2TOPO, TiOSO4"2TOPO, to be extracted with non-polar solvents.
C~.H9C )
\
C4HgO-"-~P----~0
UO2C12-3TBP,
and
CaHr/
\
CeHI?----p ~----0
(1.11)
C4HgO/
(1.12)
CeH(
High molecular-weight amines are of particular importance in the extraction [35-39]. They form ion-associates with acids (e.g., HSCN, HReO4, HI), metal-complex acids [e.g., H2PtC16, HFeC14, H2UO2(SO4)212, and heteropoly acids. These complexes are extractable into non-polar solvents (e.g., C6H6, CHC13, CC14) and polar solvents (e.g., MIBK, amyl alcohol). Tertiary amines, such as tribenzylamine (TBA) and tri-n-octylamine (TOA) are most commonly used. Tertiary and secondary amines are used for extraction of anions from acid solutions, whereas quaternary ammonium salts enable also extraction from neutral and alkaline solutions. Secondary and tertiary amines and quaternary ammonium salts are applied as solutions in non-polar solvents. Diphenylguanidine (formula 1.13) is also frequently used in extraction.
~
N\
H
.C-m--NH
(1.13)
Some amines which extract anions from aqueous solutions as ion pairs are called liquid anion exchangers [40,41]. They are marketed commercially under such trade names as Aliquat-336 and Amberlite LA-1. They are mixtures of secondary or tertiary amines, or quaternary ammonium salts, with alkyl groups having 7-12 carbon atoms. Antipyrine and its derivatives [42,43] such as diantipyrylmethane (DAM, formula 1.8) are high molecular-weight amine extractants. In acid solutions, diantipyrylmethane is protonated, and the resulting cation combines with an anion to form an ion-associate (e.g., DAM.H+] [T1Br4-], [DAM.H+]z[CdI42-]. Ion associates formed by large cations and large anions need not be solvated and are extracted with inert solvents, such as CHC13, CC14, or toluene. Examples of large cations forming non-solvated salts are the tetraphenylarsonium ion (formula 1.14) and tetraphenylphosphonium ion. These cations form extractable ion-pairs with anions such as C104-, ReO4-, SbC16-, GaC14-, CdI42-, and SCN-.
(1.14)
Macrocyclic compounds have been proposed for selective extractive separation of metals, mostly alkali and alkaline earth metals [44-51 ]. An exhaustive review of applications of these compounds is given in articles [44,49]. Macrocyclic compounds form cationic
10
1. Separation and preconcentration of elements
complexes with some metal ions, and when associated with suitable anions (e.g., picrate, perchlorate, tetraphenylborate) these can be extracted into non-polar solvents such as CH2C12, CHC13, C6H6.
(1.15) 0~6
~o 0
(1.16) H
An example of crown ether applied in selective separation of alkali metals is dibenzo18-crown-6 (formula 1.15). Extractive separations of metal ions are also performed with macrocyclic ligands containing nitrogen or oxygen atoms, as well as macrocycles with combinations of oxygen, nitrogen, and sulphur atoms (N-O, S-O, N-S) [45,48]. A macrocyclic compound with only nitrogen hetero-atoms (formula 1.16) is selective for copper. Cryptands (Greek kryptd = vault, crypt) are polycyclic compounds containing oxygen and nitrogen atoms, forming extractable cationic complexes (cryptates) with metal ions (in the presence of a suitable anion). Thiocrown ethers are also used for extraction separation of metal ions [52-57]. The cationic complexes formed by these ethers with Cu(I), Ag, Pd(II), Pt(II) are extractable from acidic media (e.g., by 1,2-dichloroethane) in the presence of, e.g., picric acid.
1.1.3. Isolation and separation of traces The elements which can be separated from each other and from the matrix in small and trace amounts by extraction are shown in Table 1.2. The symbols of elements are accompanied by the typical compounds used in the extractions. The extraction methods provide large possibilities in separation of traces. An important role in concentrating traces by extraction is played by organic reagents which form chelates with metal ions. Only the more important group reagents are mentioned in Table 1.2. Dithizones and dithiocarbamates, containing sulphur as the ligand atom, are particularly suitable for extraction of metals that form sparingly soluble sulphides. Ligands complexing through oxygen atoms, such as 8-hydroxyquinoline and cupferron, react preferentially with hydrolyzable metal ions. For the isolation and separation of some individual elements there exist highly selective, and even specific, extraction systems, such as nickel with dimethylglyoxime and cobalt with 1-nitroso-2-naphthol.
11
1.1. Solvent extraction
T a b l e 1.2. Separation of traces by solvent extraction
Be Bd Mg B Ca B Sr B Ba B
Ce bd
Th Bd
Sc bd Y bd La bd
Ti bd Zr bd Hf bd
V bcd Nb ebd Ta ed
Cr bdh Mo deb W ebg
Mn bc
Re eh
B e AI. bd Fe Co Ni Cu Zn Ga bcd ace acb acb acb bed Ru Rh Pd Ag Cd In he ech ace ac abc bae Os Ir Pt Au Hg TI he ce ace aec ace ace
Si
ge Ge eg Sn cde Pb acb
P
g As ceg Sb edc Bi ace
S
F Se Ecf Te Ce
Br F I F
U bd e
The traces are extracted as: a - dithizonates, b - 8-hydroxyquinolinates, c - dithiocarbamates, d - cupferronates, e - halogen complexes, f - elements, g - heteropoly acids, h - oxygen compounds
A group of the methods for pre-concentration of traces includes the extraction of metals by the resins modified with organic reagents, e.g., 8-hydroxyquinoline, DDTK [58], Bromopyrogallol Red [59], Zincon [60], and crown ethers [61]. Reviews of the methods have been presented [62,63]. In many cases the separation of mixtures must be preceded by conversion of the main component into a stable complex, in order to retain it in the solution and prevent its extraction along with the separated microcomponents. The masking agents most appropriate for individual elements are shown in Table 3.1.
1.1.4. Separation of macrocomponents The elements which can be extracted in larger quantities are shown in Table 1.3. The most numerous group comprises the halide and thiocyanate complexes, namely fluorides (Ta, Nb, Sn), chlorides [Fe(III), Sb, As, Ga, Ge, Au, Mo, T1], bromides (Au, In, T1, Ga), iodides (Bi, Sb, Cd, Hg, Sn), and thiocyanates [Zn, Co, Fe(III), Ti, Mo, U]. There are numerous examples of the extraction of macrocomponents as chloride complexes in the analysis of various materials. The extraction of iron(III) from hydrochloric acid medium, prior to determination of trace elements, has been thoroughly investigated [64]. Macroquantities of gallium were extracted from 6-7 M hydrochloric acid with di(2chloroethyl) ether [65,66], and gold(m) was extracted with isoamyl acetate [67]. As bromide complexes, indium has been extracted with diethyl ether [68] or diisopropyl ether, and gold(III) (from 3 M HBr), also with di(2-chloroethyl) ether [69].
12
1. Separation and preconcentration of elements
T a b l e 1.3. Separation of the matrix by solvent extraction
Be
af
Sc
ba Y be La e
Ce e
Th bf
Ti ae Zr ef Hf ef
V aef Nb ae Ta ae
Cr df Mo ae W ae
Mn f
Re da
Fe aef Ru ad Os ad
Co Ae Rh A Ir A
Ni ae Pd af Pt a
Cu ae Ag a Au ab
Zn ae Cd a Hg ae
AI. fe Ga af In af TI af
Ge a Sn a Pb ae
As a Sb a Bi ae
S ca Se ca Te a
Br c I c
U bef
The macrocomponents are extracted as" a - halide compounds; b - nitrates; c - free elements" d - oxygen compounds; e - cupferronates; f - acetylacetonates.
Only those organic reagents, such as cupferron and acetylacetone, which form chelates highly soluble in non-polar organic solvents, can be used in the extraction of matrix elements. Larger amounts of some metals can be extracted as nitrates [U, Th, Ce(IV), Y, Sc] or oxides (Os, Ru). Matrix yttrium or scandium are extracted with TBP from 12-13 M HNO3 [70].
1.2. Precipitation Precipitation methods for the separation of elements are based on the differences in solubility of their compounds in aqueous solutions. Precipitation methods are used for separating trace elements alone, as well as for separating macrocomponents from the traces. Trace elements are separated quantitatively from the solution by using collectors (scavengers or carriers). When macrocomponents are precipitated, the aim is to prevent trace elements from co-precipitating with the large mass of the macrocomponent precipitate. This prerequisite restricts the application of the method to cases in which co-precipitation of trace elements with the macrocomponent precipitate is negligible.
1.2.1. Separation of traces with the use of carriers When a precipitant is added to a solution containing trace amounts of an ionic species (0.1100 ~tg in 100-250 ml, 10-8-10 .5 M), the ionic species may be only precipitated partly (or not at all), even though the solubility product has been exceeded. The formation of a precipitate, i.e., crystal growth, is a complex and slow process [71 ]. The process begins with nucleation. When nucleation and further growth of nuclei occur
1.2. Precipitation
13
slowly, a condition of permanent supersaturation exists in the solution. Nuclei are formed when the first portion of precipitant is added to the solution. If the ions to be precipitated occur in macro amounts in the solution, further addition of the precipitant causes rapid transformation of the nuclei into crystals by the formation of more of the sparingly soluble compound. If, however, the solution contains only trace amounts of the ions to be precipitated, the process is virtually complete after the nucleation stage. The rneehanisrn of the action of carriers depends on the nature of both the trace substance and the carrier involved. The co-precipitation consists in separation of ions coprecipitating from the solution with particles of the carrier formed in the solution. The coprecipitation may be either isomorphous (formation of solid solutions or mixed crystals) or based on adsorption phenomena. In most cases the co-precipitation of traces consists in the formation of solid solutions. The separation by co-precipitation is not restricted by the very low concentration of the trace species. Smaller amounts can be separated by co-precipitation than by solvent extraction, which is limited by the stability of the complex extracted. The formation of a solid solution, e.g., in the separation of Pb traces with lanthanum hydroxide, consists in the replacement of some La atoms in the crystal lattice by Pb atoms. If the trace element and the collector have opposite chemical properties (acidic, basic), the co-precipitation may be the result of formation of chemical compounds. For example, traces of germanium or vanadium form germanates or vanadates in co-precipitation with Fe(III)-, AI-, or La- hydroxides, while traces of tungsten or molybdenum, on co-precipitation with Fe(III) hydroxide, form the corresponding Fe(III) tungstate or molybdate. Elements which can be pre-concentrated by co-precipitation with carriers are collected in Table 1.4. The most important forms for the co-precipitation of particular elements are given. For most elements it is possible to find a suitable form that enables the separation of traces, along with an appropriate carrier. The carriers are normally selected among related elements, although this condition is not indispensable. The elements which are co-precipitated as hydroxides can also be separated by organic reagents of the R-OH type, such as 8-hydroxyquinoline, cupferron, or B-diketones. Metal ions giving sparingly soluble sulphides may be co-precipitated by organic reagents of the RSH type, e.g., dithiocarbamates. Enough collector should be added to the sample solution to ensure that the precipitation is rapid, and that sufficient precipitate is formed for easy filtration or centrifugation. At the same time the amount of the collector should be sufficiently small for adsorption of interfering ions to be negligible. The amount of collector used depends on the volume of precipitate formed. This amount may be smaller if the species is separated as the 8hydroxyquinolinate, than in cases of precipitation as hydroxide. In practice, 2-5 mg of collector are used per 50-200 ml of sample solution. Hydroxides are often used for precipitation of traces with collectors [72-74]. With Fe(III), A1, or La as collector, traces of most analytical group I-III metals are separated by addition of excess of ammonia. Metals forming ammine-complexes, e.g., Ag, Cu, Ni, Co, Zn, and Cd remain in solution. When excess of NaOH is used for precipitation, amphoteric metals such as A1, Pb, Zn, Sn, and Cr remain unprecipitated. In this case, Fe(III), Ti, Mg, or La may be used as the collector. Lanthanum is especially convenient, since it usually does not have to be determined in the trace concentrate. It has no chromophoric properties and it does not interfere in most spectrophotometric methods.
14
1. Separation and preconcentration of elements T a b l e 1.4. S e p a r a t i o n of t r a c e s by c o - p r e c i p i t a t i o n with carriers
Ce ae
Be A Mg ae Ca ec Sr ce Ba ce
Sc ae Y ae La ae
Th ae
U ae
AI. Ti
ae Zr ae Hf ae
V
ae Nb ae Ta ae
Cr ae Mo bea W ae
Mn ab
Re ba
Fe abe Ru db Os db
Co ab Rh db Ir db
Ni Ab Pd Db Pt Db
Cu abd Ag bda Au dab
Zn ab Cd ab Hg bd
ae Ga ae In abe TI abe
Si
a Ge ab Sn ab Pb abc
P
a As b Sb abd Bi abd
CI
Se da Te da
f Br f I f
The traces are precipitated as: a; hydroxides or acids; b - sulphides; c - sulphates; d elements after reduction" e - 8-hydroxyquinolinates; f - silver salts.
Traces of hydrolyzable metals [e.g., Sn, Sb, TI(III), Bi] are separated from acidic medium with MnO2aq as the collector [75,76]. Hydrogen sulphide or thioacetamide are used for the separation of traces of metals in the form of their sulphides. Copper, mercury, and other metals of the "hydrogen sulphide" group are used as collectors [77,78]. After the collector has been added and the pH adjusted, the solution is heated with thioacetamide or the hot solution is saturated with hydrogen sulphide. All the metals of analytical group I-III are precipitated when an ammoniacal solution (pH 89) is saturated with HzS. In the analysis of high purity metals, trace elements were pre-concentrated by partial dissolution of the matrix. The remaining small part of the matrix retains all trace elements that are electrochemically less noble than the matrix [79,80]. In this way the trace elements were pre-concentrated from silver-, cadmium-, gallium-, indium-, zinc-, lead-, manganese-, aluminium-, and lead-antimony alloys. Trace amounts of noble and semi-noble metals (e.g., Au, Ag, Hg, and Cu) are separated electrolytically from acid media on a small platinum or gold cathode [81]. In cementation methods (i.e., reduction to metal in situ by another metal) small amounts of semi-noble metals (Cu, Bi, Sb) are deposited on less noble metals such as tin, iron, or zinc. Trace elements can be separated from solutions of different metals by reducing a small amount of the matrix metal with sodium hydroborate (NaBH4) [82-85]. The metallic precipitate serves as a trace collector for all the elements that are electrochemically more noble than the matrix. The method has been used in the trace analysis of lead and its alloys [82-85]. Concentrates of trace amounts of many metals are precipitated with 8-hydroxyquinoline, thionalide, or dithiocarbamates [86,87]. In addition to group systems of separating elements, shown in Table 1.4, there are also specific methods for precipitation of particular elements. For example, Pd can be precipitated with Ni as collector (and vice versa) by means of dimethylglyoxime. The rare earths and
1.2. Precipitation
15
thorium can be separated as their sparingly soluble oxalates or fluorides. Molybdenum and tungsten are separated as benzoinoximates. Active carbon can serve as collector in the separation of some trace elements precipitated in various forms [88,89]. Silicic acid has been also used as collector in preconcentration of many elements [90]. Masking plays a substantial role in the separation of traces from macrocomponents by precipitation. The aim is to retain the macrocomponents in solution while the traces are coprecipitated with a collector. The masking agent selected must complex the sample matrix without interfering with the separation of the traces and the collector. Knowledge of the stability constants of complexes is not enough to predict their masking possibilities. The stability constants of complexes are apparent constants which vary with the pH and with the concentration of other species capable of complexation (competitive reactions).The effect of these factors is taken into account in the conditional stability constants of complexes [91].
1.2.2. Separation of traces by flotation Ions of precipitate particles are adsorbed or attached at the surface of bubbles rising through a liquid, and are thereby separated. A substance which is not surface-active itself can be made so through union with, or adherence to, a surface-active agent (surfactant). Froth flotation involves separation (pre-concentration) by frothing. If an insoluble product is formed in interaction between the ion to be separated and a surfactant, the process is called ion flotation. If the ion is first precipitated and the precipitate is then floated with or without the addition of a surfactant, the process is called precipitate flotation. Flotation is accomplished in a special cylindrical vessel provided with a sintered glass disk at the bottom to break the gas (nitrogen, air) stream into small bubbles [92]. Ion flotation has been used as a method for pre-concentration of heavy metal ions in water. Anionic complexes of these elements are formed by adding complexing agents, and then floated by using a cationic surfactant and nitrogen. The amount of the surfactant should be greater than the stoichiometric amount, but excessive concentration may decrease trace recoveries [93]. Precipitate flotation is applied in the analysis of natural waters. Trace ions in an aqueous solution are co-precipitated with colloidal metal hydroxide collectors and floated with the aid of a gas stream [94-96]. Tiny gas bubbles are trapped in the interstitial spaces and on the surfaces of the precipitates to give sufficient buoyancy. Surfactant ions having the charge opposite to the precipitate surfaces are used to make the surface hydrophobic. Another important role of the surfactants (e.g., sodium oleate, sodium dodecylsulphate) is to form a stable froth layer to support the precipitate on the solution surface, which is important for complete separation of the precipitate. Instead of passage of gas bubbles through the solution, the aqueous pseudo-solution can be shaken with non-polar solvent. In such cases, hydrophobic sparingly soluble compounds accumulate at the phase boundary or adhere to the wall of the separating funnel used. After careful removal of both liquid phases, and washing, the precipitate adhering to the wall can be dissolved in a polar solvent and the isolated trace elements can be determined. Numerous elements form multicharged anionic complexes which are able to associate with hydrophobic basic dyes. They include anions of the heteropoly acids of Si, Ge, P(V), and As(V), the bromide complexes of Bi and Te(IV), and the thiocyanate complexes of Mo and W. Flotation of sparingly soluble ion-associates formed between the multicharged anionic complexes (with halides, SnC13-, and thiocyanate) of the platinum-group metals and
16
1. Separation and preconcentration of elements
gold with basic dyes (Rhodamine 6G, Crystal Violet, Methylene Blue, etc.) has been described [97,98]. The floating agents often used are DIPE, benzene, cyclohexane, and toluene. Flotation of these hydrophobic ion associates is carried out without the use of surfactants.
1.2.3. Separation of macrocomponents The precipitation of macrocomponents (matrix) to separate them from trace elements is relatively uncommon [99]. In the separation of macrocomponents their quantitative precipitation is not necessary. The largest group of elements comprises those isolated from solution in the elemental form as a result of reduction, usually electrochemical. In acid solution, the electrolytic deposition of metal on a solid cathode is limited to noble and semi-noble metals. Trace analysis of copper and its compounds may serve as an example [100]. An anodic dissolution technique may be applied for the isolation of macroscopic amounts of copper. A sample in the form of a bar, plate, or wire is the anode in the electrolytic system. When current is passed through the electrolyte (nitric acid + persulphate), Cu is deposited on the graphite cathode, while most trace elements accumulate in the solution. In the trace analysis of platinum, the matrix has been also separated on a cathode [101 ]. The use of a mercury cathode, which has a high overvoltage to hydrogen, enables a considerable number of metals to be isolated from dilute acid solutions. After electrolysis with the mercury cathode, the following metals remain in solution: A1, Ti, Zr, V, Nb, U, Th, Be, Mg, Ca, and rare-earth elements. A mercury cathode is used to separate Fe, Ni, Cr, Mo, and Mn when steel is analysed for certain elements (e.g., A1, V, Ti). Gold, silver, mercury, and platinum metals, as well as Se and Te, can be precipitated from acid solution in the elemental form by reduction with chemical reagents such as zinc, NHzOH, NzH4, SO2, or formic acid. In the trace analysis of high purity mercury the sample (about 100 g) is dissolved in HNO3 and the solution is warmed in the presence of formic acid. First of all, nitric acid, then mercury, is reduced. The mercury forms a separate liquid phase, and the impurities remain in the aqueous solution [ 102]. In the trace analysis of silver, the sample is dissolved in nitric acid, then formic acid and mercury are added. The silver liberated on reduction dissolves in the mercury to form an amalgam [ 102]. In the trace analysis of high-purity zinc, the sample is coated with a thin layer of mercury. After dissolution of the zinc in hydrochloric acid, a drop of mercury remains that contains amalgams of many trace metals from the zinc analysed. They can be determined after volatilization of mercury [ 103]. The belief that the isolation of macrocomponents from solution as sparingly soluble compounds is inadmissible in trace analysis, because of the considerable losses of traces caused by adsorption, is not necessarily true if the precipitation is done in acid medium. This has been confirmed in the following examples. In the trace analysis of lead, the matrix was precipitated from a nitric acid medium as lead sulphate. By using radioisotopes, it was found that none of the 24 elements investigated had co-precipitated with PbSO4 [104,105]. Most of the lead can also be separated as PbCI2 from nitric acid medium without perceptible co-precipitation of other components [ 104]. Before the determination of trace impurities in bismuth the latter is removed from nitric acid solution as the sparingly soluble iodide or the basic nitrate [106]. In the analysis for Cu, Zn, Cd, Ni, Pb, Mn, and Fe traces in silver, the matrix is precipitated as AgC1 from dilute nitric acid medium [107]. The trace elements do not collect
1.3. Volatility
17
with the precipitate. In the trace analysis of high-purity thallium, the matrix was separated as sparingly soluble TII [ 108]. Before the determination of impurities in metal chlorides (e.g., of sodium, potassium, calcium, aluminium), the matrix can be separated by saturating the solution with gaseous HC1.
1.3. Volatility The following group of methods for separating and preconcentrating is based on differences in the vapour pressures of individual elements and their compounds. Covalent compounds are generally fairly volatile whereas ionic compounds are not. Covalently bonded compounds are also more soluble in non-polar solvents. As both volatility and solubility in solvents depend on the strength of intermolecular attractions, there is a fair resemblance between the compounds which are volatile and those which are readily soluble in non-polar solvents. Examples are AsC13, GeC14, OsO4, and certain inner chelates [ 109].
1.3.1. Separation of traces Volatilization is usually utilized for separating individual trace elements from the sample before the determination. The methods based on volatilization are concerned mainly with non-metallic and amphoteric elements which have high vapour pressure in the elemental form (e.g., chlorine, bromine, sulphur), or in compounds with halogen, hydrogen, or oxygen. Other volatilization methods exist for the separation of certain elements, such as the distillation of boron as methyl borate. A method has been proposed for preconcentration of traces of the more volatile elements (e.g., Zn, Cd, T1, In, Pb) by heating samples in quartz tubes to about 1,000 ~ in a stream of hydrogen. The sublimed metals are collected on a cold-finger. Many metal halides have been volatilized from aluminium samples by heating to 990 ~ [110]. Volatile acetylacetonates and other g-diketonates have also been utilized for the separation of metals [lll]. The separation of traces is done in a closed system and involves absorbing the traces in a suitable sorbent, for example hydrogen sulphide in a zinc acetate solution, ammonia in dilute HC1, and methyl borate in dilute NaOH. In the Gutzeit method traces of arsenic, liberated in the form of ASH3, are absorbed by a strip of paper saturated with a reagent giving a colour effect with ASH3. In all such procedures a carrier gas, such as hydrogen, nitrogen, chlorine, or steam is indispensable The volatility of some elements can be reduced by binding them in complexes. The fact has been utilized for increasing the selectivity of separation of traces by distillation. For example, Ge and As can be separated from Sn by distillation as the chlorides, after Sn(IV) had been masked as the non-volatile phosphate complex.
1.3.2. Separation of macrocomponents If the macrocomponents can be removed by volatilization (distillation, sublimation) without the introduction of large amounts of reagents, the trace elements may be greatly concentrated. This favourable situation, in which relatively large samples can be used for trace analyses, arises when the sample is volatile, especially when it is a liquid such as water, an organic solvent, a volatile acid, or an ammonia solution.
18
1. Separation and preconcentration of elements
During evaporation of the matrix, substances are sometimes added to reduce the volatility of the trace components which are to be retained in the vessel. A few drops of concentrated sulphuric acid are usually added, and the solution is evaporated until fuming [112]. In certain cases, the trace element is kept in solution as a less volatile complex during the distillation of the sample matrix. In the determination of boron traces in chlorosilanes, silicon is removed as the volatile fluoride complex. To prevent the formation of volatile BF3, mannitol is added to form a non-volatile complex with boron [ 113]. Chlorine, bromine, iodine, sulphur, and mercury are distilled as the elements. Examples of the distillation of major elements as the fluoride complexes can be found in the trace analysis of silicon [ 113]. Tin can be sublimed as the iodide [ 114]. In the trace analysis of titanium [115], and zirconium, volatile chlorides (TIC14 and ZrC14) are sublimed after heating the samples with chlorine. In the trace analysis of rubidium- and caesium arsenates, arsenic is distilled off as arsine [116]. In the trace analysis of high purity cadmium, the matrix can be separated by distillation at 630~ [ 1171. By heating aluminium with ethyl bromide the metal is converted into ethylaluminium bromide, a liquid which boils at 130~ under reduced pressure [ 118]. Mineralization of organic samples [119-121], which precedes the determination of inorganic components, is also an example of separation of major components by volatilization (principally as CO2 and H20). In the mineralization of organic substances by dry ashing, the mineral residue may be so small and light that considerable losses result from the formation of "volatile" aerosols. These losses are prevented by adding a mineral collector, e.g., by wetting the sample with a solution of Mg(NO3)2, K2SO4, or Na2CO3. The temperature should not exceed 400-500~ to prevent distillation of more volatile elements [122]. At 400~ As and Hg volatilize completely, and Ag, Au, Fe, Sb, Zn, and Pb partially volatilize. Mercury is lost during wet mineralization with acids. It volatilizes on heating a solution in sulphuric acid to fuming.
1.4. Ion-exchange and sorption 1.4.1. Introduction Organic ion-exchangers are used for the separation of ions and for the separation and preconcentration of traces from the sample macrocomponents (matrix). Ion-exchange processes are based on the differences in ionic charge, in stability of the complexes formed, and in the associated distribution coefficients [ 123,124]. The organic ion exchangers are obtained by co-polymerization. They contain ionizable functional groups. The functional groups in cation exchangers are: -SO3H,-COOH, and -OH; those in anion exchangers are:-NR3 +, -NR2,-NHR, and NH2. A strongly acidic cation exchanger is prepared by sulphonation of a co-polymer of styrene and divinylbenzene (DVB). Dowex 50 X8 is the ion exchanger Dowex 50 crosslinked with 8% DVB. The hydrogen ion of acid groups is exchanged for other cations in the exchange process. The cation exchanger may be used in the hydrogen (H+), sodium (Na+), or similar form, depending on the cation attached to its acid groups. A strongly acidic character is imparted to cation exchangers by sulphonic acid groups. In anion exchangers, a strongly basic character is imparted by quaternary ammonium groups. Anion exchangers are most often used in the hydroxide (OH-) or chloride (C1-) form.
1.4. Ion exchange and sorption
19
In separation methods, ion exchange is usually performed by the column technique. The wet swelled resin is placed in a glass, quartz, or plastic column, and the solution studied is run through the column. In simple ion exchange separations some kinds of ions are retained in the column while others are eluted. In ion exchange chromatography the ions retained by the ion exchanger are gradually eluted by appropriate, selective eluents, and are collected in different portions of the eluate. The size of the column (resin bed) is selected according to the quantity of ions to be retained in the column. The depth of the resin bed in the column should be 10-20 times its diameter. Columns 8-10 mm in inner diameter are often used in laboratories. When the quantities of ions retained are in the microgram or milligram range, columns 3-5 mm in inner diameter are sufficient. In columns of the dimensions given above, 30-50 mesh or 100-200 mesh resins may be used [ 125 The ion-exchange capacity of the column depends on the quantity of resin in the column and on the ion-exchange capacity of the resin used. The latter is expressed in meq of ionic species per gram of dry resin. For strongly basic anion-exchangers it amounts to 4-5 meq per gram. In practice, it is not the total capacity of the ion-exchange column which is important, but the breakthrough capacity, which is lower and depends on the column shape, resin particle size, elution rate, and other experimental conditions. The distribution coefficient (D) for a particular element, on a given ion exchanger, and in the given medium, is the ratio of the element concentration in the resin bed phase, Cr (in millimoles per gram of dry resin) to the element concentration in the solution in equilibrium with the ion exchanger, c~ (in millimoles per ml of solution). D=
Cr Cs
The ability of an ion exchanger to retain an element from a solution of a particular complexing agent is shown by a graph of log D v s . complexing-agent concentration. The concentrations of complexing agents modify the affinity of the ions to the ion exchangers. The ion exchange methods were applied also in mixed aqueous-organic media [126]. The addition of organic solvents to the aqueous system modifies the affinity of the ions for ion exchangers. The fact may be explained by change in the solvation of the ions, reduction in the dielectric constant of the medium, and stabilization of complexes which are weak in aqueous solution. Most ion exchangers have a microporous structure, in which the pore size does not exceed 4 nm. Separations in mixed aqueous-organic media or in organic solutions are usually performed with the use of macroporous ion-exchange resins with mean pore size ranging from 130 nm. They are characterized by lesser swelling ability, more rapid exchange processes, and higher chemical resistance. The application of ion-exchange chromatography in inorganic analysis has been discussed widely [127-132]. The development of methods involving chelating ionexchangers and other sorbents will be discussed in further paragraphs. The use of molecular spectroscopy as a detection method in chromatography has also been discussed [133].
1.4.2. Separation with the use of cation exchangers Strongly acidic cation exchangers, such as Dowex 50 and Amberlite IR-120, are most often used in ion-exchange separations.
20
1. Separation and preconcentration of elements
The behaviour of elements on strongly acidic cation-exchangers in hydrohalic acid solutions has been extensively investigated. Distribution curves have been reported for individual elements separated on cation exchanger in 0.5-12 M HC1 [134], and separations in mixed media HCl-water-organic solvent were studied [135,136]. Studies of ion exchange on macroporous ion-exchangers were also carried out in the media of HCl-water-acetone [137] and HCl-acetic acid-water [138]. The behaviour of metal ions on a strongly acidic cation-exchanger in the mixed medium HBr-water-organic solvents was studied [139,140]. The behaviour of metal ions in the presence of thiourea has been described [141]. In the separation of elements on strongly acidic cation-exchangers, use was also made of fluorides [142], thiocyanates in aqueousorganic media [143], perchlorates [144], oxalates [145], and tartrates [146]. An interesting application of a cation exchanger has been given in relation to trace analysis of sodium-, potassium-, barium-, and strontium chlorides [147]. Metal cations are retained by the cation exchanger. Concentrated HC1 run onto the column precipitates NaC1, KC1, BaC12, and SrCI2, whereas trace metals present are eluted.
1.4.3. Separations with use of anion exchange resins Strongly basic anion-exchange resins, such as Dowex 1 and Amberlite IRA-400, are mostly used in the separation and preconcentrations to be discussed. The behaviour of elements on strongly basic anion-exchangers in hydrochloric acid medium has been studied [148,149]. The behaviour of some elements in mixed media HC1water-organic solvents has been a subject of some work [ 150,151 ]. Detailed data have been published on the behaviour of some elements on anion exchangers in the media of fluoride [152], nitric acid [153], sulphuric acid [154,155], and in the mixed medium HCl-acetic acid-water [138]. Studies were also carried out on the behaviour of elements on strongly basic anion exchangers in the media of HBr [156,157], phosphoric acid [158], oxalic acid [159], thiocyanate [160], tartrate [161], and thiosulphate [162]. Schemes have been given for the separation of iron and alloy components, and admixtures in steel of A1, Bi, Co, Cr, Mn, Mo, Nb, Ni, Sn, Ta, Ti, V, W, and Zr. Columns with strongly basic anion-exchangers and with strongly acidic cation exchangers were used, and various media (HF, HC1, and H2804 were applied) [163]. Weakly acidic anion exchangers were used in the separation of metals in chloride [ 164] and thiocyanate [165] media.
1.4.4. Chelating resins and other sorbents Chelating resins play a substantial role in the preconcentration and separation of trace elements 166-168]. These sorbents are especially useful in trace analysis of natural waters. Chelating resins are characterized by high selectivity, which depends mainly on the chelating groups involved. Various matrices are used in the synthesis of chelating resins: copolymers of styrene and divinylbenzene, polystyrene, polymethacrylate, and fibrous materials such as cellulose. Also used are modified anion exchangers, charcoal, and other materials impregnated (loaded) with chelating agents. Chelex-100 is a well-known resin based on styrene-divinylbenzene copolymer with iminodiacetate groups. It has found many applications in preconcentration of traces of heavy metals such as Cu, Cd, Zn, Ni, Co, Mn, Fe, Pb, and Hg [169-172].
References
21
From among numerous chelating agents used in chelating resins can be mentioned: oxine [173,174], dithiocarbamates [175-178], dithizone [179], nitrosonaphthols [180], thiazolothiol [181], Arsenazo I [182], and formazans [183]. Anion exchangers have been modified with chelating agents, such as dithizone, Arsenazo III, Sulphonazo III [184], Xylenol Orange [185], and BPHA [186]. The sorption of metal traces on resins modified with azo reagents was also studied [187,188]. Cellulose is a natural hydrophilic porous polymer. Owing to the presence of hydroxyl groups in cellulose it is possible to introduce chelating groups into it. Cellulose sorbents are characterized by good kinetic properties and high distribution coefficients [189]. Cellulose sorbents with functional groups derived from dithiocarbamates [190] or 1-(2hydroxyphenylazo)-2-naphthol [191] are known. Fibrillar chelating sorbents based on synthetic organic products have been proposed [192]. Chelating sorbents based on silica gel have been proposed. Among organic reagents supported on silica gel are: oxine [193], rhodanine [194], and other reagents containing thiol groups [195]. The use of macrocyclic ligands (bonded with silica gel) for the separation of metal ions has been investigated [ 196,197].
Inorganic ion exchangers have not been applied widely, but in some cases they can be useful in separation and preconcentration of trace elements. They include hydrous oxides and acid salts of multivalent metals, heteropoly acids (e.g., phosphomolybdenic acid), sparingly soluble ferrocyanides, and synthetic aluminosilicates (zeolites) [198,199].
References 1. Zolotov Yu.A., Pure Appl. Chem., 50, 129 (1978). 2. Minczewski J., Chwastowska J., Dybczyfiski R., Separation and Preconcentration Methods in Inorganic Trace Analysis, Horwood, Chichester 1982. 3. Mizuike A., Enrichment Techniques for Inorganic Trace Analysis. Chemical Laboratory Practice, Springer, Berlin 1983. 4. Zolotov Yu. A., Kuz'min N.M., Preconcentration of Trace Elements, Elsevier, Amsterdam, 1990. 5. Marcus Y., Talanta, 23, 203 (1976). 6. Rydberg J., Musikas C., Choppin G.R., Principles and Practices of Solvent Extraction, Dekker, New York 1992. 7. Bock R., Freitag K.D., Z. Anal. Chem., 254, 104 (1971). 8. Alimarin I.P., Zolotov Yu.A., Bodnya V.A., Pure Appl. Chem., 25, 667 (1971). 9. Danesi P.R., Chiarizia R., Crit. Rev. Anal. Chem., 10, 1 (1980). 10. Akiba K., Freiser H., Anal. Chim. Acta, 136, 329 (1982). 11. Bagreev V.V., Pomandopulo Yu.I., Zh. Anal. Khim., 35, 358 (1980). 12. Studlar K., Coil. Czech. Chem. Comm., 31, 1999 (1966). 13. Byrne A.R., Gorenc D., Anal. Chim. Acta, 59, 81 (1972). 14. Blokhin A.A. et al., Zavod. Lab., 45, 693 (1979). 15. Donaldson E.M., Talanta, 23, 411,417 (1976). 16. Donaldson E.M., Mark E., Talanta, 29, 663 (1982). 17. Riedel A., J. Radioanal. Chem., 13, 125 (1973). 18. Chwastowska J., Lissowska K., Sterlifiska E., Chem. Anal. (Warsaw), 19, 671 (1974). 19. Onishi H., Sekine K., Talanta, 19, 473 (1972). 20. Ionov V.P., Chicherina N.Yu., Zh. Anal. Khim., 36, 236 (1981); 39, 1581 (1984). 21. Zolotov Yu.A., Gavrilova L.G., Zh. Anal. Khim., 25, 813, 1054 (1970).
22
1. Separationand preconcentrationof elements
22. H~la J., J. Radioanal. Chem., 51, 15 (1979). 23. Petrov B.I., Galinova K.G., Margulis V.B., Zh. Anal. Khim., 50, 1781 (1985). 24. Spivakov B.Ya., Zolotov Yu.A., Zh. Anal. Khim., 25, 616 (1970). 25. Goriushina V.G., Biriukova E.Ya., Zh. Anal. Khim., 24, 580 (1969). 26. Rublev V.V., Zh. Anal. Khim., 38, 922 (1983). 27. Spivakov B.Ya., Petrukhin O.M., Zolotov Yu.A., Zh. Anal. Khim., 27, 1584 (1972). 28. Gagliardi E., W6ss H.P., Anal. Chim. Acta, 48, 107 (1969). 29. Yakovlev Yu.B., Kolotov V.P., Zh. Anal. Khim., 36, 629 (1981). 30. Gurkina T.V., Litvinova E.Ya., Zh. Anal. Khim., 24, 267 (1969). 31. Prokoshev A.A., Chuchalin L.K., Zh. Anal. Khim., 27, 1364 (1972). 32. Donaldson E.M., Wang M., Talanta, 33, 233 (1986). 33. Zolotov Yu.A., Bagreev V.V., Kutyrev I.M., Anal. Chim. Acta, 78, 397 (1975). 34. Sultanova Z.Kh., Zolotov Yu.A. et al., Zh. Anal. Khim., 28, 413 (1973). 35. Moore F.L., Anal. Chem., 37, 1235 (1965). 36. Ueno K., Saito A., Anal. Chim. Acta, 56, 427 (1971). 37. G6rin M., Fresco J.,Anal. Chim. Acta, 97, 165 (1978). 38. Kasiura K., Chem. Anal. (Warsaw), 31, 143 (1986). 39. Sato T., J. Radioanal. Nucl. Chem., 101, 77 (1986). 40. Green H., Talanta, 11, 1561 (1964); 20, 139 (1973). 41. Karalova Z.K., Myasoedov B.F., Zh. Anal. Khim., 39, 119 (1984). 42. Moroshkina T.M. et al., Zh. Anal. Khim., 34, 872 (1979). 43. Petrov B.I., Zh. Anal. Khim., 38, 2051 (1983). 44. KolthoffI.M.,Anal. Chem., 51, 1R (1979). 45. Zolotov Yu.A. et al., Zh. Anal. Khim., 37, 1543 (1982). 46. Krasnushkina E.A., Zolotov Yu. A., Trends Anal. Chem., 2, 158 (1983). 47. Arpadjan S., Mitewa M., Bontchev P.R., Talanta, 34, 953 (1987). 48. Suchan W.W., Kronikowski O.I., Nazarenko A.J., Zh. Anal. Khim., 43, 1953 (1988). 49. Blanko Gomis D., Arias Abrodo P., Sanz Medel A., Quim. Anal. (Barcelona), 7, 371 (1988). 50. Beck E., Greenway G.M., Anal. Proc., 32, 313 (1995). 51. Zolotov Yu.A., Macrocyclic Compounds in Analytical Chemistry, Wiley, New York, 1997. 52. Saito K., Masuda Y., Sekido E., Anal. Chim. Acta, 151,447 (1983). 53. Lachowicz E., Krajewski A., Golifiski M., Anal. Chim. Acta, 188, 239 (1986). 54. Sekido E., Chayama K., Muroi M., Talanta, 32, 797 (1985). 55. Chayama K., Sekido E., Anal. Sci., 3, 535 (1987). 56. Muroi M., Sekido E., Anal. Sci., 9, 691 (1993). 57. Saito K., Taninaka I., Murakami S., Muromatsu A., Anal. Chim. Acta, 299, 137 (1994). 58. Nickson R.A., Hill S.J., Worsfold P.J., Anal. Proc., 32, 387 (1995). 59. Sun X., Li B., Fu K., Mikrochim. Acta, 1990 III, 101. 60. Kocjan R.,Analyst, 119, 1863 (1994). 61. Yakshin V.V., Vilkova O.M., Tsarenko N.A., Zh. Anal. Khim., 49, 173 (1994). 62. Berrueta L.A., Gallo B., Vicente F., Chromatographia, 40, 474 (1995). 63. Fritz J.S., Dumont P.J., Schmidt L.W., J. Chromatogr. A., 691, 133 (1995). 64. Specker H., Shirodker R., Z. Anal. Chem., 214, 401 (1965). 65. Shelpakova I.P., Yudelevich I.G., Chanysheva T.A., Zh. Anal. Khim., 34, 2293 (1979). 66. Yudelevich I.G., Gil'berg E.N., Shelpakova I.P., Zh. Anal. Khim., 36, 2393 (1981). 67. Marczenko Z., Kasiura K., Krasiejko M., Chem. Anal. (Warsaw), 14, 1277 (1969). 68. Kasiura K., Chem. Anal. (Warsaw), 11, 141 (1966).
References
23
69. Yudelevich I.G. et al., Zh. Anal. Khim., 25, 153 (1970). 70. Slyusareva R.L. et al., Zh. Anal. Khim., 37, 237 (1982). 71. Liteanu C., Lingner H., Talanta, 17, 1045, 1052 (1970). 72. Strohal P., Molnar K., Ba6i6 I., Mikrochim. Acta, 1972, 586. 73. Lebedinskaya M.P., Chuiko V.T., Zh. Anal. Khim., 28, 2413 (1973). 74. Strohal P., N6thig-Hus D., Mikrochim. Acta, 1974, 899. 75. Burke K.E., Anal. Chem., 42, 1536 (1970). 76. Briska M., Z. Anal. Chem., 276, 197 (1975). 77. Marczenko Z., Kasiura K., Chem. Anal. (Warsaw), 10, 449 (1965). 78. Tikhomirova A.A., Patin S.A., Morozov N.P., Zh. Anal. Khim., 31,282 (1976). 79. Jackwerth E., Messerschmidt J., Anal. Chim. Acta, 87, 341 (1976). 80. Jackwerth E., Messerschmidt J., H6hn R., Anal. Chim. Acta, 94, 225 (1977). 81. Olm D.D., Stock J.T., Mikrochim. Acta, 1977 II, 575. 82. Jackwerth E., H6hn R., Musaick K., Z. Anal. Chem., 299, 362 (1979). 83. Jackwerth E., Musaick K., Mikrochim. Acta, 1981, Suppl. 9, 71. 84. Skogerboe R.K., Hanagan W.A., Taylor H.E., Anal. Chem., 57, 2815 (1985). 85. Danz H.J., Jackwerth E., Z. Anal. Chem., 326, 57 (1987). 86. Berndt H., Messerschmidt J., Z. Anal. Chem., 299, 28 (1979). 87. Scheubeck E., Mikrochim. Acta, 1980 II, 283. 88. Jackwerth E., Lohmar J., Wittier G., Z. Anal. Chem., 266, 1 (1973). 89. Marczenko Z., Mojski M., Balcerzak M., Mikrochim. Acta, 1975 I, 539. 90. Jackwerth E., Messerschmidt J., Anal. Chim. Acta, 107, 177 (1979). 91. Inczedy J., R6wnowagi kompleksowania w chemii analitycznej, PWN, Warszawa 1979. 92. Mizuike A., Hiraide M., Pure Appl. Chem., 54, 1555 (1982). 93. Andreeva I.Yu., Lebedeva L.I., Drapchinskaya O.L., Zh. Anal. Khim., 40, 694 (1985). 94. De Carlo E.H., Zeitlin H., Fernando Q., Anal. Chem., 53, 1104 (1981). 95. Sonawane M.J., Hiraide M., Mizuike A., Anal. Chim. Acta, 149, 359 (1983). 96. Cabezon J.M. et al., Talanta, 31,597 (1984). 97. Marczenko Z., Pure Appl. Chem., 57, 849 (1985). 98. Marczenko Z., Kalinowski K., Chem. Anal. (Warsaw), 32, 451 (1987). 99. Townshend A., Jackwerth E., Pure Appl. Chem., 61, 1643 (1989). 100. Barabas S., Lea S.G., Anal. Chem., 37, 1132 (1965). 101. Marczenko Z., Maruszak J., Chem. Anal. (Warsaw), 27, 391 (1982). 102. Meyer J., Z. Anal. Chem., 219, 147 (1966); 231, 241 (1967). 103. Jackwerth E. et al., Z. Anal. Chem., 260, 177 (1972). 104. Jackwerth E., Pure Appl. Chem., 51, 1149 (1979). 105. Wang Z., Cheng K.L., Talanta, 29, 551 (1982). 106. Mizuike A., Kawaguchi H., Kono T., Mikrochim. Acta, 1970, 1095. 107. Jackwerth E., Schmidt W., Z. Anal. Chem., 225, 352 (1967). 108. Jackwerth E., Lohmar J., Schwark G., Z. Anal. Chem., 260, 101 (1972). 109. Kutal C., J. Chem. Educ., 52, 319 (1975). 110. Spachidis C., Bfichmann K., Z. Anal. Chem., 300, 343 (1980). 111. Honjo T., Imura H., Shima S., Kiba T., Anal. Chem., 50, 1545 (1978). 112. Marczenko Z., Mojski M., Chem. Anal. (Warsaw), 12, 1155 (1967). 113. Marczenko Z., Mojski M., Kasiura K., Chem. Anal. (Warsaw), 14, 1331 (1969). 114. Schweinsberg D.P., Heffernan B.J., Talanta, 17, 332 (1970). 115. Devyatykh G.G. et al., Zh. Anal. Khim., 33, 464 (1978). 116. Fedyashina A.F., Yudelevich I.G., Zh. Anal. Khim., 21, 1232 (1966). 117. Raji6 S.R., Markovi6 S.V., Anal. Chim. Acta, 50, 169 (1970).
24
1. Separationand preconcentrationof elements
118. Neeb K.H., Z. Anal. Chem., 221, 200 (1966). 119. Adrian W.J.,Analyst, 98, 213 (1973). 120. Schachter M.M., Boyer K.W., Anal. Chem., 52, 360 (1980). 121. Blanu~a M., Bregki D., Talanta, 28, 681 (1981). 122. Strohal P., Luli6 S., Jelisav6i6_ O., Analyst, 94, 678 (1969). 123. Marhol M., Ion Exchangers in Analytical Chemistry. Their Properties and Use in Inorganic Chemistry, Academia, Prague, 1982. 124. Harland C.E., Ion Exchange: Theory and Practice, Royal Soc. Chem., Cambridge, 1994. 125. Aubouin G., Laverlochbre J., J. Radioanal. Chem., 1, 123 (1968). 126. Moody G.J., Thomas J.D., Analyst, 93, 557 (1968). 127. Yi Z., Zhuang G.S., Brown P.R., J. Liq. Chromatogr., 16, 3133 (1993). 128. Xianren Q., Chong-Yu X., Baeyens W., J. Chromatogr., 640, 3 (1993). 129. Timberbaev A.R., Bonn G.K., J. Chromatogr. A., 640, 195 (1993). 130. Nesterenko P.N., Tarasenko D.A., Shpigun O.A., Zh. Anal. Khim., 49, 244 (1994). 131. Hu W. et al., Anal. Chem., 67, 3713 (1995). 132. Lucy C.A., J. Chromatogr. A., 739, 3 (1996). 133. Korte E.H., Fresenius'J. Anal. Chem., 333, 753 (1989). 134. Mann C.K., Swanson C.L., Anal. Chem., 33, 459 (1961). 135. Strelow F.W., Victor A.H., Van Zyl C.R., Eloff C., Anal. Chem., 43, 870 (1971). 136. Strelow F.W., Victor A.H., Talanta, 19, 1019 (1972). 137. Strelow F.W., Talanta, 35, 385 (1988). 138. Kasiura K., Chem. Anal. (Warsaw), 42, 809 (1997). 139. Korkisch J., Klakl E., Talanta, 16, 377 (1969). 140. Strelow F.W., Hanekom M.D., Victor A.H., Eloff C., Anal. Chim. Acta, 76, 377 (1975). 141. Weinert C.H., Strelow F.W., Talanta, 30, 755 (1983). 142. Korkisch J., Huber A., Talanta, 15, 119 (1968). 143. Pietrzyk D.J., Kiser D.L., Anal. Chem., 37, 233 (1965). 144. Strelow F.W., Sondorp H., Talanta, 19, 1113 (1972). 145. Nozaki T. et al., Bull. Chem. Soc. Jpn., 42, 245 (1969). 146. Strelow F.W., Van der Walt T.N., Anal. Chem., 54, 457 (1982). 147. Tera F., Ruch R.R., Morrison G.H., Anal. Chem., 37, 358 (1965). 148. Yoshimura J., Waki H., Bull. Chem. Soc.Jpn., 35, 416 (1962). 149. Seymour M.D., Fritz J.S.,Anal. Chem., 45, 1394 (1973). 150. Fritz J.S., Gillette M.L., Talanta, 15, 287 (1968). 151. Koch W., Korkisch J., Mikrochim. Acta, 1972, 687; 1973, 245,263,877. 152. Ferraro T.A., Talanta, 16, 669 (1969). 153. Walter C.W., Korkisch J., Mikrochim. Acta, 1971, 81,137, 158, 181,194. 154. Strelow F.W., Bothma C.J., Anal. Chem., 39, 595 (1967). 155. Lavrukhina A.K., Akol'zina L.D., Zh. Anal. Khim., 22, 542 (1967). 156. Strelow F.W.,Anal. Chem., 50, 1359 (1978). 157. W6dkiewicz L., Dybczyfiski R., Chem. Anal. (Warsaw), 26, 419 (1981). 158. Polkowska-Motrenko H., Dybczyfiski R., J. Chromatogr., 88, 387 (1974); Chem. Anal. (Warsaw), 22, 1021 (1977). 159. Strelow F.W., Weinert C.H., EloffC.,Anal. Chem., 44, 2352 (1972). 160. Kiriyama T., Kuroda R., Anal. Chim. Acta, 101,207 (1978). 161. Pitstick G.F., Sweet T.R., Morie G.P.,Anal. Chem., 35, 995 (1963). 162. Eusebius L.C., Ghose A.K., Mahan A., Dey A.K., Analyst, 105, 52 (1980).
References
25
163. G61is P., Chim. Anal., 53, 674 (1971). 164. Kuroda R., Ishida K., Kiriyama T.,Anal. Chem., 40, 1502 (1968). 165. Fritz J.S., Kaminski E.E., Talanta, 18, 541 (1971). 166. Janauer G.E., Ramseyer G.O., Lin J.W., Anal. Chim. Acta, 73, 311 (1974). 167. Myasoedova G.V., Savvin S.B., Zh. Anal. Khim., 37, 499 (1982). 168. Myasoedova G.V., Shcherbinina N.I., Savvin S.B., Zh. Anal. Khim., 38, 1503 (1983). 169. Brajter K., Miazek J., Talanta, 28, 759 (1981). 170. Koshima H., Anal. Sci., 2, 255 (1986). 171. Van Berkel W.W. et al., J. Anal. At. Spectrom., 3, 249 (1988). 172. Savvin S.B., Mikhailova A.V., Zh. Anal. Khim., 51, 49 (1996). 173. Parrish J.R., Stevenson R., Anal. Chim. Acta, 70, 189 (1974). 174. Seubert A., Petzold G., McLaren J.W., J. Anal. At. Spectrom., 10, 371 (1995). 175. Mahanti H.S., Barnes R.M.,Anal. Chim. Acta, 149, 395 (1983). 176. Park Y.J., Hardy J.K., J. Chromatogr., 481, 287 (1989). 177. Fritz J.S., Freeze R.C., Thornton M.J., Gjerde D.T., J. Chromatogr. A., 739, 57 (1996). 178. Irth H., Brinkman U.A., Trends Anal. Chem., 9, 235 (1990). 179. Chwastowska J., Kosiarska E., Talanta, 35, 439 (1988). 180. Ghosh J.P., Pramanick J., Das H.R., Talanta, 28, 274, 957 (1981). 181. Sugii A., Ogawa N., Hagiwara Y., Talanta, 31, 1079 (1984). 182. Chwastowska J., Chem. Anal. (Warsaw), 32, 643 (1987). 183. Hoshino H., Nakano K., Yotsuyanagi T., J. Chromatogr., 515, 603 (1990). 184. Chikuma M. et al., Talanta, 27, 807 (1980). 185. Brajter K., Olbrych-Sleszynska E., Talanta, 30, 355 (1983). 186. Chwastowska J., Przygoda D., Chem. Anal. (Warsaw), 31, 545 (1986). 187. Basova E.M., Bol'shova T.A., Shpigun O.A., Ivanov V.M., Zh. Anal. Khim., 48, 1094 (1993). 188. Pesavento M., Profumo A., Sastre A., Talanta, 41, 1689 (1994). 189. Wegscheider W., Knapp G., Crit. Rev. Anal. Chem., 11, 79 (1981). 190. Imai S. et al., Anal. Chim. Acta, 113, 139 (1980). 191. Burba P., Lieser K.H., Z. Anal. Chem., 286, 191 (1977); 298, 373 (1979). 192. Shcherbinina N.I., Myasoedova G.V., Savvin S.V., Zh. Anal. Khim., 43, 2117 (1988). 193. McLaren J.W., Mykytiuk A.P., Willie S.N., Berman S.S., Anal. Chem., 57, 2907 (1985). 194. Terada K., Morimoto K., Kiba T.,Anal. Chim. Acta, 116, 127 (1980). 195. Volkan M., Ataman O.Y., Howard A.G., Analyst, 112, 1409 (1987). 196. Bradshaw J.S. et al., Solvent Extr. Ion Exch., 7, 855 (1989). 197. Chyueh S.D., Liu C.Y., Fresenius'J. Anal. Chem., 354, 278 (1996). 198. Vesely V., Pekarek V., Talanta, 19, 219, 1245 (1972). 199. R62owski J., Mojski M., Chem. Anal. (Warsaw), 35, 591 (1990).
Chapter 2. Principles of Spectrophotometry 2.1. Introduction Spectrophotometric methods are among the oldest methods of analytical chemistry. The absorption of visible light by certain chemical substances has long been used for visual determination of their concentration. As early as in the middle of the XIX century methods were known for the determination of bromide in natural waters by oxidation and extraction of the resulting bromine into ether, of ammonia by Nessler's method, of titanium by the peroxide method, and of molybdenum by the thiocyanate method. The term "colorimetry" was used for those analytical methods, in which chemical elements were determined by comparing the colour of unknown samples with appropriate standards, either in graduated cylinders or in visual comparators. The use of photoelectric instruments has given rise to measurement of the absorption of radiation as it passes through the analysed samples and has enabled us to extend the useful radiation range outside the visible region. Nowadays, spectrophotometry is regarded as an instrumental technique, based on the measurement of the absorption of electromagnetic radiation in the ultraviolet (UV, 200-380 nm), visible (VIS, 380-780 nm), and near infrared region. Inorganic analysis uses UV-VIS spectrophotometry. The UV region is used mostly in the analysis of organic compounds. Irrespective of their usefulness in quantitative analysis, spectrophotometric methods have also been utilized in fundamental studies. They are applied, for example, in the determination of the composition of chemical compounds, dissociation constants of acids and bases, or stability constants of complex compounds. Spectrophotometry as a measuring technique has developed enormously as a consequence of the progress in technology, and in the development of new materials and of methods of data processing. The development of specialized optics, and of spectrophotometers coupled with microprocessors controlling their operation, has extended considerably the possibilities of using these instruments, the recording of absorption spectra, and the treatment of the data collected. Spectrophotometric methods have proved to be particularly suitable for automation, both in analytical procedures and in the treatment of data. They belong to the detection techniques most frequently used in automatic flow injection analysis (FIA).
2.2. Absorption and molecular structure Spectrophotometric methods of identification and determination of substances are based on the existence of relationships between the position and intensity of absorption bands of electromagnetic radiation, on the one hand, and molecular structure on the other. Electronic spectra result from changes in the energy states of electrons [o, x, and free electron pairs (n)] in a molecule as a result of absorption in the UV-VIS region. The changes depend on the probability of electronic transitions between the individual energy states of the molecule. The number of absorption bands, and their positions, intensities and shapes are the spectral parameters utilized in qualitative and quantitative chemical analyses [1-3]. The positions of individual absorption bands recorded in the spectra depend on the energy of the absorbed radiation. Radiation from the near-infrared region gives rise to changes in the rotational and oscillation energy states in a molecule. Narrow bands that are due to small
2.2. Absorption and molecular structure
27
changes in wave number are connected with characteristic groups of atoms (functional groups) and are used for identification of such groups. The UV-VIS radiation gives rise to changes in the energy of electronic states of a molecule. The probability of electronic transitions in a molecule depends on the presence of multiple bonds in the molecule and on the kind, number and positions of the substituent groups. Determination of the kind of transitions corresponding to the observed bands of absorption spectra enables one to determine the structure of the molecule. Spectral transitions of electrons associated with absorption of radiation correspond to transitions from binding orbitals ((y, x, n) to anti-bonding orbitals of higher energy state (o*, ~*). The energy of the respective transitions decreases in the following order: o--~ o * > n --~ o * > 7t--~7t*> n ~
m*
The o---> cy* transitions may take place in the far ultraviolet, which is generally not recorded in spectrophotometers. Other transitions occur in the near ultraviolet and visible regions. The n ~ ~* transitions are characterized by high intensity which varies depending on the number and kind of multiple bonds in the molecule. An increase in the number of conjugated bonds results in a reduction of the distance between the ~ and x* levels, an increase in the probability of transition, and increase of intensity of the spectrum recorded. The considerable bandwidth and the high intensity are characteristic for absorption bands due to intermolecular charge transfer without ionization. They appear when an electron is transferred, under the effect of radiation energy, from a donor molecule to a free orbital of another molecule (acceptor). The charge transfer bands occur in the near ultraviolet and are broad in general. The visible and the near UV regions are characterized by absorption bands owing to intraatomic d - d transitions. This kind of transition is specific for ions of transition metals with an incomplete d shell. Splitting of the d sub-levels in the ligand field creates a possibility of transitions between the levels due to absorption of appropriate radiation quanta. The colour of solutions of transition metal ions is connected with the intra-atomic d - d transitions. The transition metals are capable of forming coloured complexes even with colourless reagents, which do not contain chromophoric groups. Changes in the energy of electrons within the ligands, charge-transfer bands, and bands owing to intra-atomic transitions determine finally the shape of the absorption spectrum of the given compound. The position and the intensity of electronic spectra may change when substituents are introduced into the molecule or when its environment is changed. The colour of a molecule is an effect of the presence of ehromophorie groups. A chromophore may be a group of atoms containing easily excitable ~ electrons (formula 2.1), including the most important groups for the visible region: the azo group - N = N - and the pquinonoid system.
,---N---~'O
~
.--C~N
/N~--~.S
(2.1)
The changes in the energy levels of these electrons owing to the absorption of radiation quanta give rise to characteristic bands in the absorption spectrum. The more easily the bond electrons in a molecule are excited, the more intense is the colour of the compound. The shape of the spectrum and the intensity of the absorption band depend on the position of the
28
2. Principles of spectrophotometry
chromophores in the molecule. In isolated systems, where multiple bonds are separated from each other by at least two single bonds, the spectra contain absorption bands characteristic for individual chromophores. Where double bonds are present in conjugated systems, intense absorption bands, shifted towards longer wavelengths, appear in most cases. The features of the absorption spectra change if the so-called auxoehromes (e.g., -NH2, -NR2, -SH, -OH, -OR) are introduced into the molecules. The presence of free electron pairs in the auxochromic group, that interact with Ic- electrons of the chromophoric group (e.g., the free electron pair at nitrogen in t h e - N H 2 group) leads to a state of conjugation which may result in formation of a new absorption band in the spectrum. An action of a substituent or a solvent may give rise to a shift of absorption band towards longer wavelengths - the bathochromic effect, or towards shorter wavelengths - the hypsochromic effect. An increase or a decrease of band intensity is referred to as the hyperchromic or the hypsochromic effect, respectively. The shape of a spectrum and its intensity depend on the positions of substituents in the molecule and on their inter-relationships, as in cis- and trans- isomers. In general, higher band intensities, and shifts to the higher wavelength part of the spectrum, are characteristics of the trans isomers, in which the coupling of ~- electrons is stronger for spatial reasons. The intensities and the positions of absorption bands may also be influenced by solvent molecules. Electrostatic dipole interactions, and specific interactions that lead to formation of complexes based on hydrogen bonds and of charge-transfer type complexes, result in changes in the spectra of chemical compounds. As the pH is increased, spectrophotometric reagents ionize and their electronic structure becomes deformed, which often leads to a bathochromic shift of the absorption maximum. Ionization causes polarization of the chromophoric system. The formation of a chelate complex disturbs the electronic state of the organic molecule to produce, as a rule, a bathochromic shift.
2.3.
Absorption laws
Spectrophotometric measurements are generally made on solutions, either in water or in organic solvents, contained in a measuring cell which is placed in the path of a beam of monochromatic radiation of chosen wavelength. From the total radiation of intensity Io that impinges upon a layer of solution, one fraction of the beam Ia is absorbed on passing through the solution, another fraction/t is transmitted, and still another fraction/r is reflected by the cell walls and scattered: l o = Ia + l, + lr
As absorption measurements are always made by comparison with a standard solution, and both the sample and the standard are placed in identical cells, the part of radiation denoted as/r is constant and may be neglected. The amount of radiation absorbed depends on the thickness of the absorbing layer and on the concentration of the solution [4,5]. In 1729 Bouguer established the relationship between the amount of absorption (the absorbance) and the thickness of the absorbing layer. A mathematical formulation of this relationship was given by Lambert in 1769. In 1852, Beer settled a relationship between the absorbance and the concentration of coloured solutions. In the formula derived (the Bouguer-Lambert-Beer law) both the solution concentration and the layer thickness are taken into account.
2.3. Absorption laws When a parallel beam of monochromatic radiation of intensity Io impinges upon solution of thickness dl, a part of the radiant energy is absorbed. If the layer changes, the absorption changes proportionally. The fraction absorbed exponentially with linear increase of the layer thickness: dI -kdl I where k is a constant, and the minus sign denotes that the intensity of the transmitted decreases as the thickness of the layer increases. Integration of the above equation gives the following expression:
29 a layer of thickness increases
=
radiation
In ~I~= kl I where Io denotes the initial beam intensity (for 1 = 0). By conversion of natural logarithms to decimal ones the above equation assumes the following form: log Io/'It - 0.434 In Idlt = 0.434 K1 - A where K is a new constant, and A is the absorbance. The absorbanee is a logarithm of the ratio of incident beam intensity, Io' to the intensity of the beam transmitted,/t. If the concentration, c, of the absorbing species is doubled and the absorbing layer thickness is reduced by a factor of two, then the total number of absorbing molecules remains the same, hence the absorbance A will also remain the same. Therefore the absorbance is a function of the number of absorbing centres in the light-beam, i.e., of the product cl, and the above equation can be given the form: A = log Io/It = ,F_cl where e is a new constant called the molar absorptivity (or absorption coefficient), c is the concentration of absorbing species (M, in moles per litre), and l is the layer thickness (in
cm). The equation is a mathematical expression of a fundamental law of spectrophotometry, the B o u g u e r - L a m b e r t - B e e r law, which states that absorption of radiation depends on the total number of absorbing centres, i.e., on the product of concentration and layer thickness of the solution. In spectrophotometric measurements the thickness of the sample layer is usually identical to that of the reference solution, and only Beer's law, which relates the absorbance with the concentration of the sample solution, is of practical significance. If a solution contains more than one absorbing species and there is no interaction between the components, the total absorbance of the solution is equal to the sum of all the component absorbances. The law of additivity of absorbance (providing the optical path length is constant) is expressed by the formula: A = (elCl + e 2 C 2 + . . . + enCn)l The additivity of absorbance constitutes the basis for studies of multicomponent systems. If a coloured solution obeys Beer's law, the graph of A = f(c) is a straight line passing through the origin. From a practical point of view it is desirable that the solution should follow Beer's law for the concentration range corresponding to absorbances not exceeding 1 (unity). Deviations from Beer's law may result from either chemical reasons connected with the sample, or physical ones connected with the instruments involved [6-8]. In the former case
30
2. Principles of spectrophotometry
the deviations are due to changes in the form of the determined component as a consequence of chemical reactions (e.g., hydrolysis, solvation, association, polymerization) associated with changes in the analyte concentration. Any change in the form of the substance being determined gives rise, as a rule, to changes in its optical properties. Thus, for example, dichromate ions (orange) are transformed, on dilution, into yellow chromate ions: Cr2072- + H20 ----~2CrO42- +2H +. In the case of weak complexes, a dilution of the solution leads to a dissociation and decomposition of the complex thus giving rise to deviations from Beer's law. Beer's law is not obeyed in systems where complexes are formed in a stepwise manner. The reaction constants and the quantitative ratios of individual complexes depend on the concentration ratio of the reactants and the pH of the reaction medium. The optical medium must be homogeneous. Turbid solutions give deviations from Beer's law. Such deviations occur in two-phase systems insufficiently homogenized by protective colloids. Deviations from Beer's law may also arise from insufficient quality of measuring instruments, mainly from the use of non-ideal monochromatic light, improper width of the spectral band, or scattering of radiation. The detector signal should be proportional, over a wide range, to the intensity of the radiation recorded. Despite the many possibilities of deviation from Beer's law, in the absorbance range of practical interest for analytical purposes, colour systems not conforming to Beer's law are fairly rare.
2.4. Spectrophotometric apparatus The quality of the measuring instrument has a strong influence on the reliability of the results obtained. The standard spectrophotometric apparatus used in modern analytical laboratories is very different from the equipment used in the initial period of application of this technique. The progress in the development of spectrophotometric apparatus up to the middle of the 1980s has been described [9-11]. The trends in the development of UV-VIS spectrophotometry, with special consideration to improved detection, and modern methods of data treatment, have been discussed [12]. The following discussion will be devoted to apparatus installed in most analytical laboratories. The set of components that enable us to record a radiation absorption spectrum consists of: radiation source, monochromator, cuvette, and detector with the data treatment system (Fig. 2.1). Radiation source
hydrogen, xenon, tungsten, or halogen lamp
~
Monochromator
Cuvette
prism or diffraction grating
sample
solution
I-t
Detector
~-~ systemMeasuring
photocell, photomultiplier, photoresistor, or photodiode
galvanometer or
microprocessor
Fig. 2.1. Block diagram of spectrophotometer The intensity of light emitted by the source, the effectiveness of its monochromatization, and the sensitivity of the detector are decisive for the quality of the spectrophotometer.
2.4. Spectrophotometric apparatus
31
2.4.1. Radiation sources and monochromators In most cases spectrophotometers are equipped with two independent radiation sources: UV and VIS. The UV source is usually a deuterium- or xenon lamp that emits radiation in the range of 180-400 nm or 190-750 nm, respectively. The development of the UV radiation sources has been reviewed [13]. The sources emitting visible light are tungsten- and halogen lamps. A feature of the halogen lamps is their wider spectral range, higher radiation intensity, and longer lifetime. In modem spectrophotometers the exchange between the UV and VIS proceeds automatically. The increasing use of lasers as high intensity sources of monochromatic radiation is observed [ 14]. The principal element of the spectrophotometer is the monochromator which serves for dispersion of the radiation emitted by the source and isolation of a beam of monochromatic radiation of definite wavelength. The monochromator comprises a system of slits, a collimator, a light-dispersing element, and lenses or mirrors to focus the dispersed radiation. The dispersing system is the essential part of the monochromator. The degree of monochromatization is an important feature of the dispersing element. Beams of monochromatic radiation or radiation of wavelength comprised within a specified narrow range are isolated by means of filters, prisms, or diffraction gratings. The beams of radiation of a limited range of wavelength are separated from the continuous spectra by means of properly selected colour filters. Modem spectrophotometers are equipped with diffraction gratings, whose dispersion is independent of the kind of material used and the wavelength of radiation applied. Gratings of 1,800 and 2,400 grooves/mm are used for the UV region, and those with 600 and 1,200 grooves/mm are applicable for the visible light. The separation of the grooves, denoted as the grating constant, is the parameter characteristic for the given grating. The high precision of forming the grooves and the regularity of their separations are characteristic for holographic diffraction gratings having up to 6,000 grooves/mm. The substitution of diffraction gratings for prisms enabled researchers to increase the spectral resolution and to extend the measuring range from 1 to 4 in the absorbance scale. To record a diffraction spectrum in a required wavelength range it is necessary to change the position of the grating to isolate the beam of a given wavelength. The manual method of changing the position, used in former instruments, has been replaced by mechanical systems. Quick and precise changes in position of the diffraction grating may be obtained by means of a laser beam.
2.4.2. Measuring cuvettes Measuring cuvettes, in which sample solutions are placed, are made of various materials depending on the range of radiation used in the measurement. Measurements in the UV are performed with the use of quartz cuvettes. Synthetic quartz, which is less contaminated with traces of metals, has better optical properties. Measurements in the VIS range are made using quartz, glass, or plastic cuvettes. The cuvette should provide maximum transmission of radiation and definite, precisely known thickness of the light-absorbing layer. Cuvettes of different thicknesses within the range 5 ~tm - 10 cm are produced. Small cuvettes capable of accepting samples of volumes down to 100 ~tl are also available. Small volume cuvettes that enable multiple passage of the beam of radiation are of special interest [ 15].
32
2. Principles of spectrophotometry
The cuvette material should be resistant to the action of chemicals. The cuvettes are placed in measuring chambers in special holders that provide accurate and reproducible location of the sample in the path of the radiation beam. Cuvettes of special design are used for measurements over wide ranges of temperature and pressure or under conditions of permanent flow. An automatic method for cleaning the cuvettes has been proposed [16].
2.4.3. Detectors After traversing the measuring cuvette the radiation impinges on the detector. The role of the detector is to convert the energy of the incoming electromagnetic radiation into electrical energy. The signal transformation should be linear, which means that the electrical signal generated should be proportional to the optical signal received. This condition is successfully fulfilled by photocells, photomultipliers, photoresistors and photodiodes. A comparison of various detectors used in UV and VIS spectrophotometry has been given [ 17]. The operation of photocells and photomultipliers is based on the external photoelectric effect. Photons impinging on the surface of a photosensitive cathode (photocathode) knock out electrons which are then accelerated in the electrical field between the cathode and the anode and give rise to electric current in the outer circuit. The spectral sensitivity of a photocell depends on the material of the photocathode. The photocathode usually consists of three layers: a conductive layer (made, e.g., of silver), a semiconductive layer (bimetallic or oxide layer) and a thin absorptive surface layer (a metal from the alkali metal group, usually Cs). A photocathode of the composition, Ag, Cs-Sb alloy, Cs (blue photocell), is photosensitive in the wavelength range above 650 nm; for longer wavelengths the red photocell with Ag, Cs-O-Cs, Cs is used. The response time of the photocell (the time constant) is of the order of 10-s s. Photomultipliers are equipped with several supplementary diodes (dynodes) to which the electrons emitted from the photocathode are directed. The electrons impinging on the dynodes give rise to the emission of secondary electrons from the successive dynodes and they thus amplify the signal generated by a factor of up to 108. In the photoresistors and photodiodes use is made of the internal photoelectric phenomenon and of specific properties of semiconducting materials. Photons impinging on the photosensitive element generate an electrical current, which flows through the photoconductor and is amplified by the effect of a small applied voltage. The increase of the current intensity is proportional to the intensity of photons that strike the photosensitive element. The microcrystalline layer of lead(H) sulphide deposited on a dielectric (glass or quartz) plate may serve as an example of a photoresistor applied in the wavelength range above 700 nm. Photodiodes are made of two or three layers of semiconducting materials containing suitable admixtures. Silicon photodiodes are used in the UV-VIS range Modern spectrophotometers are equipped with multichannel detecting devices that contain a large number of photodiodes (a photodiode array) and enable simultaneous detection over the whole range of the spectrum. Details of the design and the advantages of using such detectors in spectrophotometric measurements have been presented [17-20].
2.4.4. Data recording and processing The application of microprocessors and the rapid development of computer techniques has made it possible to automate the analytical operations from the step of sampling up to
2.5. Spectrophotometric techniques
33
full processing of the data obtained. In modern spectrophotometers, microprocessors are applied to control many operations that were formerly operated manually. The functions now realized by microprocessors include the control of the optical system (lamp and analytical wavelength selection), selection of the kind of data collected (e.g., absorbance, concentration), zero-adjustment, autocalibration and control of measurement parameters [21]. The microprocessor determines the equation of the regression curve and provides statistical processing of the results. It can also be programmed to measure the absorbance, the % transmittance at a selected wavelength, or the concentration based on the relationship (linear or non-linear) established between the measured absorbance and the concentration. The advanced spectrophotometers are coupled with computers that facilitate the recording of results and the processing of the data obtained. Appropriate software enables the presentation of results on the display, smoothing of the obtained spectrum, calculation of peak heights with respect to the base-line, and mathematical processing of the results that provides the possibility of, e.g., resolving signals owing to individual components of the sample analysed (see "Derivative Spectrophotometry" in Section 2.5). The development of the computer techniques has facilitated the identification of the structures of chemical compounds by enabling quick and easy access to catalogues of UV-VIS spectra. The data recorded and the results obtained can be stored in the computer memory. This gives the possibility of comparing the obtained results and evaluating their quality by rapid comparison with greater numbers of data. A critical evaluation of the obtained results always remains the task of the analyst.
2.5. Spectrophotometric techniques If the value of the molar absorptivity, e, for the wavelength used in measurement of absorbance of the given system is known, it is possible to determine directly the concentration of the analyte by means of an equation based on Beer's law. The value of e is determined from the measurement of absorbance of several solutions containing precisely known amounts of the analyte under conditions identical to those used in the measurement of the sample solution. In analytical practice, the concentration of the given analyte is, in most cases, determined by the standard curve technique. The technique is based on the determination of the relationship between the absorbance and the analyte concentration under the measuring conditions. The relationship is given in terms of the regression equation, or graphically in the form of a standard curve. For systems that obey Beer's law this curve is a straight line. The determination error is smaller if the absorption of radiation is a consequence of the nature of the analyte itself, as with the coloured ions of transition metals. Conversion of the analyte into a form capable of absorbing radiation in proportion to its concentration requires some additional procedures (such as the use of a chromogenic reagent, pH adjustment, or addition of masking agents), that must be identical in the treatment of standard solutions and of the sample solution. The absorbance measurements must be carried out after the equilibrium has been settled in the system. If the absorbance varies with time, the time of measurement should be strictly specified. In analytical practice, use is sometime made of standard curves in which the changes in absorbance are inversely proportional to changes in the analyte concentration. The analyte concentration is found from the reduction of absorbance of the system, which is proportional to the amount of the analyte. The accuracy and the precision of determination depend on the
34
2. Principles of spectrophotometry
precise knowledge of the initial reagent concentration and on the reproducibility of the reaction conditions for different concentrations of the analyte. Differential spectrophotometry [22,23] consists in the measurement of the absorbance of a solution of the given element, not with reference to the solvent used, but with reference to a solution of this element (in the form of a coloured complex) of known concentration, slightly lower than the concentration of the solution studied. In this technique, the measuring error is in proportion to the difference of concentrations (and not to the concentration of the analyte in the solution under test), which enables one to reduce the relative error. Grey filters of appropriate absorbance have been proposed as references [24]. The theoretical bases of differential spectrophotometry have been presented [22]. The relative error of absorbance measurement is 0.2-0.5%, and is less in differential spectrophotometry [25-28] than in the regular method. Hence, the precision of differential spectrophotometry is comparable with that of gravimetric and titrimetric methods. This fact enables the technique to be applied in the determination of higher contents of the analytes. In definite coloured systems the concentrations of reference solutions are selected with a view to obtaining maximum precision of the measurements. Particular attention is required in the preparation of standard solutions. In cases where temperature variations may influence the absorbance measurements, thermostating of the system is required.
Spectrophotometric titration [29-32] consists in repeated measurement of an absorbance which changes in the course of titration of the sample solution. The use of this method depends on the existence of a linear relationship between the absorbance measured and the concentration of the absorbing substance in the solution being titrated. The course of the titration is represented graphically by two intersecting straight lines. To find the titration end-point it is necessary to determine the absorbance at two points before and two points behind it. The graphs are drawn in the system of A (absorbance) v e r s u s v (volume of titrant solution). To increase the accuracy of determination, corrections are made for the dilution caused by the addition of the titrant solution. The sample solution is titrated, at a definite wavelength, in a titration vessel placed inside the spectrophotometer. For this reason the spectrophotometers commonly applied require some adaptations that enable one to place a suitable titration vessel, the tip of the burette, and a mixer inside it. In this technique, the parameter of primary importance is not the absolute value of the absorbance measured but its changes during the course of titration. To reduce the effect of dilution on the absorbance one is recommended to use concentrated titrant solutions and micrometric syringes. Spectrophotometric titrations are used in cases where it is difficult to determine the endpoint visually as, for example, when there is a permanent change in the colour of the system. Good results are obtained in titrations of rather dilute solutions, of the order of 10.5 M. Spectrophotometric titrations are often performed in automatic systems. Dual-wavelength spectrophotometry [33-36] is applied in systems where the difference in absorbance of two absorbing components at definite wavelengths may be used for determination of their concentrations in the given solution. The choice of the wavelengths depends on the system studied. Usually one wavelength corresponds to the maximum absorption of the analyte, and the other may correspond to an absorption maximum of the reagent or of an interfering species. The highest sensitivity is obtained when the absorption is measured at )Lmaxof the analyte. A necessary condition is that the
2.5. Spectrophotometrictechniques
35
individual components obey Beer's law. The errors associated with the use of the dualwavelength technique have been estimated [34-36].
Derivative spectrophotometry [37-44] is an analytical technique that uses the 1 st to 5 th (I-V) -order derivatives of absorption spectra in the VIS and UV ranges. The recorded curve of the derivative of the spectrum (the derivative spectrum) represents the values of absorbance differentials as a function of wavelength (wave-number) according to the following equation: d"A ~="Dxx d,t
= f (,t)
where n denotes the order of derivative and "Dx,,~ is the value of the n-th derivative of absorption spectrum of the substance X at the given wavelength, 2. The height of the signal of the respective derivative is proportional to the analyte concentration: d"e "Dx,,t - d2, "1. c and is additive in cases where the system contains more than one component absorbing in the radiation range studied. The shape of the derivative spectrum depends on the shape of the zero-order spectrum. The width of the half-height band (L- band-width in the middle of its height) is an important parameter characterizing the system in derivative spectrophotometry. The derivative spectrophotometry methods provide higher selectivity and higher sensitivity than do the methods based on normal (zero-order) absorption spectra. The increase in selectivity (with reduction or elimination of the effect of the spectrum of one substance on the spectrum of another one) results from reducing the band-width in the derivative spectra. An appropriate order of derivative spectrum may give complete separation of the spectra owing to the corresponding components of the system). The increase of selectivity in the derivative spectrophotometry methods results from the fact that the values of derivatives increase, in the case of basic spectra characterized by sharp peaks, and decrease in cases of broad-band zero-order spectra (Fig. 2.2). The sharp-peak spectra enable one to make determinations of analytes in the presence of considerable excess of elements having flat spectra. An example may be the direct determination of traces of manganese (as MnO4-) in nickel salts, based on the fourth-order derivative spectrum [45]. An increase of selectivity may also be obtained by proper selection of the instrument setting parameters in recording the derivative spectra. The derivative spectra are obtained in spectrophotometers fitted with microprocessors which enable digital processing of the spectra recorded [10,44-46]. Derivative spectra may also be obtained using spectrophotometers coupled with analogue differentiating systems. The instrument parameters affecting the shape of the obtained spectra are: scanning rate, integration time, distance between measurement points, and degree of amplification. The Savitzky-Golay algorithm [47,48] is that used most frequently in the treatment of basic spectra aiming at obtaining suitable derivatives. The analytical value of the derivative is determined mostly by the zero-crossing method (determination of the derivative at the zero point of the derivative for the interfering component), by the peak-to-peak method (determination of the amplitude of the derivative spectrum in a point corresponding to the maximum difference between the derivatives of the
36
2. Principles of spectrophotometry
analyte and the interfering component), and by the baseline-to-peak method (determination of the derivative of the analyte spectrum at its maximum). The sources of errors in determinations by derivative spectrophotometry have been discussed [48]. o)
b)
c)
d)
~e.eeejpme~ .....
e)
. ,
. . . . .
wavelength, nm
Fig. 2.2. Zero-order absorption spectra (a) and their derivatives: 1st order (b), 2nd order (c), 3rd order (d), and 4th order (e). Broken lines - substance 1 and substance 2; continuous line - mixture of substances 1 and 2.
Derivative spectrophotometry is applied more and more widely in the determination of inorganic and organic substances without preliminary separation. It is also used for the identification of organic substances. The dependence of the recorded signal upon the instrument parameters is a disadvantage of this technique. Reproducible results are obtained on using one M and the same M type of spectrophotometer and identical conditions of spectra recording, or by adaptation of a definite method to the available apparatus. Flow injection analysis (FIA) is an automated method which consists in the injection of the sample solution to a continuous stream of an inactive carrier (e.g., a pH buffer or water) [49-51 ]. The diluted analyte is transported to a reaction spiral where a chromogenic reagent is added to the mixture. The dimensions of the spiral, the volume of the sample injected, and
References
37
the flow rate are optimized to provide proper reaction conditions, sensitivity, and selectivity. The liquid zone formed in the spiral and carrying the analyte is transported, by means of a pump, to the detector. The signals from the detector, which are proportional to the analyte concentration in the sample injected into the carrier stream, are recorded continuously. Spectrophotometry is a technique most frequently applied in flow injection analysis, mainly owing to the easy coupling of the two methods, and good reproducibility of the measuring conditions. Practically all rapid reactions suitable for use in spectrophotometric determinations may be utilized under conditions of flow injection analysis. FIA coupled with spectrophotometry is a rapid (several dozens of determinations per hour) and sufficiently precise analytical technique [50-54]. The method uses small sample volume (10-100 ~tl), which is the basis of high sensitivity and is particularly useful in cases where small amounts of sample material are available (e.g., physiological fluids). The automation includes often also the sample injection. The spectrophotometry coupled with FIA has found numerous applications in determinations of chemical elements in environmental and clinical samples, especially in laboratories involved in rapid serial analyses.
Turbidimetry is a technique based on measurement of the absorbance by suspensions of sparingly soluble compounds. The media determined should be turbid systems, and not colloidal solutions stabilized by protective colloids. Turbidimetric determinations are often realized by visual methods or by comparison with standards in measuring cylinders, e.g., the determination of sulphate as BaSO4, or chloride as AgC1. The absorption of light by a suspension depends on the dispersion of the suspended solid which depends, in turn, on the concentration of the ions determined, the rate of adding the reagents, the temperature, and the ionic strength of the solution, and the presence of organic solvents miscible with water. Turbid solutions used in this technique do not generally obey Beer's law and the precision of determinations is rather low, since it is difficult to keep experimental conditions strictly reproducible. Higher sensitivity is attained in the case of coloured suspensions, such as metal sulphides.
References 1. Sommer L., Analytical Absorption Spectrophotometry in the Visible and Ultraviolet. The Principles, Elsevier, Amsterdam 1989. 2. K~cki Z., Podstawy spektroskopii molekularnej, PWN, Warszawa 1992. 3. Cygafiski A., Metody spektroskopowe w chemii analitycznej, WNT, Warszawa 1997. 4. Lothian G. F.,Analyst, 88, 678 (1963) 5. Buijs K., Maurice M. J., Anal. Chim. Acta, 47, 469 (1969). 6. Agterdenbos J., Vlogtman J., van Breekhoven L., Talanta, 21,225 (1974). 7. Agterdenbos J., Vlogtman J., Talanta, 21, 231 (1974). 8. Youmans H. L., Brown H.,Anal. Chem., 48, 1152 (1976). 9. Altemose I. R., J. Chem. Educ., 63, A 216 (1986). 10. Altemose I. R., De Long L. E., Locke L. E., J. Chem. Educ., 63, A262 (1986). 11. Nowicka-Jankowska T., Wieteska E., Gorczyfiska K., Michalik A., Spektrofotometria UV/VIS w analizie chemicznej, PWN, Warszawa 1988. 12. Lobifiski R., Marczenko Z., Crit. Rev. Anal. Chem., 23, 55 (1992). 13. Jones K. P., Trends Anal. Chem., 9, 195 (1990). 14. Imasaka T., Shibashi N.,Anal. Chem., 62, 363A (1990). 15. Dagsupta P. K.,Anal. Chem., 56, 1401 (1984).
38
2. Principles of spectrophotometry
16. Bautz D. E., Ingle J. D. Jr., Anal. Chem., 59, 2534 (1987) 17. Grossman W. E. J., J. Chem. Educ., 66, 697 (1989). 18. Borman S. A., Anal. Chem., 55, 836A (1983). 19. Jones D. Anal. Chem., 1057A, 1207A (1985). 20. Dose E. V., Guiochon G.,Anal. Chem. 61, 2571 (1989). 21. George W. O., Willis H. A., Computer Methods in UV, VIS and IR Spectroscopy, Royal Society of Chemistry, Cambridge, 1990. 22. Barkovski V. F., Ganopolski V. I., Spektrofotometryczna analiza r62nicowa, WNT, Warszawa 1971. 23. Grossmann O., Z. Anal. Chem., 321,442 (1985). 24. Marczenko Z., Ramsza A., Chem. Anal. (Warsaw), 21, 805 (1976). 25. Ingle J. D., Anal. Chem., 45, 861 (1973). 26. Blank A. B., Zh. Anal. Khim., 28, 1435 (1973). 27. Kotar' N. P., Samoilov V. P., Zh. Anal. Khim., 30, 465 (1975). 28. Grossmann O., Z. Anal. Chem., 320, 112, 223,229 (1985). 29. Ringbom A., Skrifvars B., Still E.,Anal. Chem., 39, 1217 (1967). 30. Galik A., Talanta, 13, 109 (1966); 15, 771 (1968); 17, 115 (1970). 31. Sato H.,Anal. Chim. Acta, 96, 215 (1978). 32. Johns P., Price W. J., Analyst, 95,138 (1970). 33. Shibata S., Furukawa M., Honkawa T., Anal. Chim. Acta, 78, 487 (1975). 34. Ratzlaff K. L., Natusch D. F., Anal. Chem., 49, 2170 (1977). 35. Ratzlaff K. L., Daraus H. B., Anal. Chem., 51, 256 (1979). 36. Ratzlaff K. L., Natusch D. F.,Anal. Chem., 51, 1209 (1997). 37. O'Haver T. C., Green G. L., 48, 312 (1976). 38. Ishii H., Z. Anal. Chem., 319, 23 (1984). 39. Perfil'ev V. A., Mishchenko V. T., Poluektov N. S., Zh. Anal. Khim., 49, 1349 (1985). 40. Levillain P., Fompeydie D. Analusis, 14, 1 (1986). 41. Dubrovkin I. M., Zh. Anal. Khim., 43, 968 (1988). 42. Talsky G., Derivative Spectrophotometry, CCH, Weinheim 1994. 43. Bosh Ojeda C., Sanchez Rojas F., Cano Pavon J. M., Talanta, 36, 549 (1980). 44. Ku~ M., Marczenko Z., Obarski N., Chem. Anal. (Warsaw), 41,899 (1996). 45. Ku~ M., Marczenko Z., Talanta, 36, 1139 (1996). 46. Majer J. R., Azzouz A. S., Talanta, 27, 549 (1980). 47. Savitzky A., Golay M. J., Anal. Chem., 36, 1627 (1964). 48. Steinier J., Termonia Y., Dektour J.,Anal. Chem.. 44, 1906 (1972). 49. Ru~i6ka J., Hansen E.,Anal. Chim. Acta, 179, 1 (1986). 50. Trojanowicz M., Automatyzacja w analizie chemicznej, WNT, Warszawa 1992. 51. Karlberg B., Pacey G. E., Wstrzykowa analiza przeptywowa dla praktyk6w, WNT, Warszawa 1994. 52. Ru~i6ka J., Hansen E.,Anal. Chim. Acta, 78, 145 (1975); 99, 37 (1978). 53. Ranger C. B., Anal. Chem., 53, 21A (1981). 54. Stewart K. K., Talanta, 28, 789 (1981).
Chapter 3. Spectrophotometric methods 3.1. Introduction The spectrophotometric methods to be discussed (methods of molecular absorption spectrometry) are based on the measurement of absorption of radiation, in the visible and near ultraviolet regions, owing to coloured compounds formed, before the determination, by the elements to be determined. Only seldom is use made of the intrinsic colour of the element itself, in its ionic form. In cases where an element neither forms coloured compounds nor occurs in a coloured form, indirect spectrophotometric methods are applied. Spectrophotometric methods are characterized by high versatility, sensitivity, and precision. They may be used for the determination of almost all chemical elements over a wide range of concentrations, from macroquantities (by means of differential spectrophotometry) to traces ranging from 10-6-10 -8 % (after suitable preconcentration). Spectrophotometric methods are among the most precise instrumental methods of chemical analysis. The advantages mentioned of the spectrophotometric methods are made greater by their availability. A spectrophotometer, which is the basic instrument in this field, is cheaper than most other fundamental instruments used in chemical analysis. Spectrophotometric methods are extensively discussed in the literature [ 1-4]. Spectrophotometric methods were preceded by colorimetric methods. The colorimetric determinations were first performed in cylinders, then visual colorimeters with filters came into use. The first photoelectric colorimeters were introduced into laboratory practice in the 19308, and they were next replaced by spectrophotometers. Spectrophotometers do not measure or compare the colour, but measure the absorbance of solutions. The application of organic reagents, the development of the knowledge of complexes, then the use of spectrophotometers equipped with microprocessors that enable rapid processing of absorption spectra [5-9] have led to a very rapid development of spectrophotometric methods [ 10-24]. A paper has been published on the Recommendations of the Analytical Chemistry Section of the International Union of Pure and Applied Chemistry (IUPAC) concerning the nomenclature, symbols and units applied in molecular absorption spectrometry [25].
3.2. Sensitivity The sensitivity of an analytical method means a minimum concentration, minimum amount, or a minimum difference in concentrations, of an element that can be determined by this method. Later on, use will be made of the first meaning of the term. The numerical value of the sensitivity of spectrophotometric methods is usually determined in terms of the molar absorption coefficient (molar absorbance, ~, a coefficient) measured at the wavelength at which the absorbance is being measured: A ~=
cl
40
3. Spectrophotometric methods
where A is the absorbance, c is the concentration (in mole per litre) and l is the layer thickness (in cm). The molar absorption coefficient (e) is expressed in 1.mole-l.cm-1. Conforming to the principles of metrology, the value of the coefficient should be given with consideration to the meaningful number of digits or the precision of measurements. Therefore it is rational to give, e . g . , ~ - 4.2.104 or 4.20.104, not ~ = 42,000. In the former cases the number of significant digits is two or three, whereas in the latter case it is five. In sensitive spectrophotometric methods the values of the molar absorption coefficient are usually greater then 2.104 , whereas values below 1.103 correspond to methods of low sensitivity. As a result of the underlying quantum theory, the value of e cannot be greater than 1.5-105. Higher values are possible in some indirect methods, e . g . , in spectrophotometric amplification methods. The knowledge of e enables one to compare the sensitivities of the methods of determination of one and the same element or of elements having similar atomic masses. The sensitivity of spectrophotometric methods can be expressed conveniently and compared (especially in the case of elements differing considerably in atomic mass) in terms of the specific absorbanee (a) [26] which is obtained by dividing ~ by the molar mass of the element and by 1,000: a--
c mol.m. . 1000
The value of a corresponds to the absorbance of a solution of a given element at concentration 1 lag/ml (= 1 ppm)in a cuvette of layer thickness 1 cm. The sensitivity of the dithizone method for determination of copper (Xmax= 550, molar mass of Cu = 63.54 g/mole) may be expressed as follows: molar absorptivity (coefficient e) specific absorptivity, a
4.52-104 1 .mole-l.cm-1 0.71 ml.~g-l.cm -1.
The value of e is most readily determined under conditions where the spectrophotometric reagent has zero absorbance at ~max of the complex, and only one stable coloured complex is formed in the system. In cases where the complex is formed stepwise [as in the system Fe(III) - SCN-] the value of e depends on the excess of the reagent. It is more difficult to determine the value of e in cases where the reagent itself absorbs the radiation at ~maxof the complex. If only one coloured complex is formed in the system, the absorbance can be measured with respect to a reference solution in which the reagent's concentration is identical with the concentration of uncombined reagent in the measured solution. If, however, more than one coloured complex is formed in presence of a coloured reagent, absorbing partly in the region of ~max of the complex, it is difficult to find a concentration range in which Beer's law is obeyed. The values of e then have only a relatively low significance, as they depend on the contributions of individual complexes in the mixture, and hence on conditions such as the excess of reagent or the pH value. In some indirect methods, the element being determined causes bleaching or changes the colour of the system. In such cases, the value of e is calculated from the change in absorption caused by a definite amount of the analyte. The determination of the coefficient e is simple in the extractive spectrophotometric methods. In many cases the extraction is associated with transformation of dichromatic solution into a monochromatic one. Several complexes may coexist in an aqueous solution,
3.2. Sensitivity
41
and the extract contains usually one complex of definite composition. Extraction usually leads to an increase in the sensitivity of the method. In cases where the element to be determined is not completely extracted into the organic phase, because its partition coefficient is too low, and the percent of extraction varies depending on the phase-volume ratio, the value of e should be specified along with the extraction conditions (phase-volume ratio, multiplicity of extractions). Despite the fact that a fraction of the analyte remains in the aqueous phase, the whole quantity of the element present in the initial solution is taken into account. Some ambiguities occurring in the calculation of the coefficient e may arise from the definition of the mole. For example, 127 g of iodine is 1 mole of I or 0.5 mole of I2; hence it is necessary to give always the chemical form of the substance for which the value of e has been determined. In some methods, the sensitivity depends on the quality of reagent used to produce the colour reaction. This is of particular importance in the case of reagents of natural origin, although some differences have been noticed also in synthetic organic reagents. The differences in sensitivity are a result of the presence of some admixtures that have a bearing on the reactions of the elements being determined, or that give rise to competitive reactions. The minimum concentration of an element (in moles per litre) that can be determined by spectrophotometric methods may be calculated from the expression: A = ecl. If one assumes that the minimum measurable absorbance of a solution is A = 0.02, with a cuvette width 1 - 2 cm, and for a moderately sensitive spectrophotometric method, e = 1.104, the respective concentration will be: c - 0.02/2.104 = 10-6 M. If we assume a mean molecular mass of the element as equal to 100 (in this case the specific absorptivity a -- 104/102.103 = 0.1) the minimum measurable concentration of the element will be: 106.102/103 = 10 -7 g/ml - 0.1 ~tg/ml In order to determine the absorbance of a solution in a cuvette of thickness 2 cm one should have 6-7 ml of coloured solution and a volumetric flask of capacity 10 ml, which corresponds to 1 gg of the element. If one assumes that saturated solutions of soluble salts have concentrations about 10 percent, then 10 ml of such a solution corresponds to 1 g of the sample. So, if 1 gg of the analyte is contained in 1 g of the sample, its concentration in the sample is 10 -4 %. In more sensitive methods, where e is of the order of 105 and the specific absorptivity is about 1.0, the limit shifts to about 10-5 %. Trace concentrations below 10 -4 % are below the sensitivity range of many methods. To have a possibility of determining them by spectrophotometric methods a preliminary concentration of trace components usually becomes necessary (see Chapter 1 on methods of preconcentration and separation of elements). Depending on the kind of sample and its weight (e.g., 10 g, 100 g, or more) such an operation can increase the sensitivity (shift the limit of determination) by 1-2 or more orders of magnitude. In such a way, the sensitivity of spectrophotometric methods can be increased to 10-6-10 -7 %. An important role in trace analysis is played by the blank test, particularly in the determination of the more common elements such as Fe, Zn, Ca, A1, Si. It happens sometimes that the content of an element in the blank exceeds its content in the sample. In such cases the blank test determines the limiting concentration of the element in the given
42
3. Spectrophotometricmethods
material. Thus, it is possible to increase the sensitivity by reducing the value of the blank test (e.g., by purification of reagents, or the use of quartz or polyethylene vessels instead of glass).
3.3. Precision and accuracy In analytical chemistry the term "precision" denotes the reproducibility of results, their scatter and consistency. The term, "accuracy" denotes the degree of proximity of the obtained results to the real (true) value. The precision of spectrophotometric methods [27-29] depends on the range of the values determined. Under optimum conditions, it ranges usually from 0.5-2%. In the differential technique, precisions ranging from 0.2 to 0.5% are attained. A matter of considerable importance for the precision of a method is the measuring error. When very low concentrations are determined the relative error is large since the (absolute) measuring error is high as compared with the value measured. When the absorbance of a strongly coloured solution is being measured, only a small part of the incident radiation is transmitted through the solution. The divisions on the logarithmic absorbance scale are so small that considerable reading errors are made. For example, absorbance 2 corresponds to 1% transmission and absorbance 3 to 0.1% transmission. Hence 0.9% of the whole scale corresponds to a 50% change in the concentration. The theoretical value of absorbance measured with maximum precision may be found in the following way: c = a log x
dc-
dc c
m
(a log e)dx
(a log e)dx axlogx
0.434dx xlogx
where c is a concentration, x is a ratio of lo/It, and a is a constant. Differentiation of the above equation, and putting the second derivative equal to zero shows that the error is minimum when log x (=A) is 0.43. In modern absorptiometric instruments, with digital reading of absorbance, the precision depends on the noise of photomultiplier used as a detector. The signal is subjected to electronic processing. The respective curve of precision error has a broad minimum at A equal to about 0.9. Such spectrophotometers can record absorbance with good precision up to values of about 2. The errors involved in the absorbance measurements are usually smaller than those associated with chemical operations. In some methods the colour reaction is not reproducible. In other methods, the colour varies with time, and the absorbance should be measured after a strictly determined lapse of time. In some systems even small variations of temperature (e.g., 3-5 ~ result in changes in colour. Some reactions are sensitive to changes of pH. A small change in pH, e.g., through 0.1 unit, may cause a 5% error. Other possible errors are caused by competitive reactions occurring in the system, or by changes in the ionic strength. The total error in an analysis of a definite material is the sum of errors made in individual stages of the analytical procedure, e.g., in sampling, sample dissolution,
3.4. Selectivity
43
preconcentration and separation of the elements, and measurement of absorbance. In the course of these operations some elements may get to the sample from the environment or may be partly lost. A matter of great importance is the determination of a blank (in trace analysis) and taking it into account in calculation of the final result. The effect of the blank test on the precision of analysis increases as smaller and smaller trace amounts of elements are determined. In the determination of concentrations ranging from 10-3-10-4% the error is usually within +10%, whereas in determinations of trace amounts in the range 10-6-10-7%, with preconcentration, the error may be as high as +30%. The size of the total error may be evaluated by comparing the obtained results of analysis with values considered to be true. Where standard samples of known composition are not available, the accuracy of determination may be evaluated if known amounts of the elements to be determined are added to the weighed sample at the beginning of the analytical procedure. The amounts added should be similar to the amounts present originally in the sample. The chemical form of the additions should be selected so that in the chemical operations they behave similarly to the original sample components. A model procedure recommended for the determination of the precision (and of the sensitivity and detection limit) of spectrophotometric methods, based on experimental data and IUPAC recommendations has been developed [30], and the analysis of errors occurring in determinations of mixture components by means of modem computerized techniques, has been published [31,32].
3.4. Selectivity Conforming to a decision of IUPAC, a selective reagent is one that reacts with only a small number of elements, and a specific reagent is one that under definite conditions reacts with only one element. The selectivity of colour reactions and of the corresponding determination methods depends on the nature of the reagent used, the degree of oxidation of the elements determined, the pH of analytical medium, and of complexing agents that mask the interfering ions. If, despite the above agents, some ions still interfere in the determination, the analyte should be isolated from the interfering elements (or conversely). Separation and isolation methods are discussed in Chapter 1. There are very few specific reagents and reactions. Among the scarce examples are cuproine for Cu(I) and bathophenthroline for Fe(II). A change of valence of some ions effectively prevents their reaction with certain reagents. As an example, Nb can be determined by the thiocyanate method in presence of Fe if this had been reduced to Fe(II). The selectivity of most methods can be increased by proper selection of the pH of the analytical medium. For reagents of the R-OH type there exists a relationship between colour reactions and hydrolytic reactions of certain elements. In strongly acid solutions, colour reactions proceed with those elements that have easily hydrolyzable cations, such as Zr, Hf, Th, U(IV) and Ti. In moderately acidic solutions the reactions also proceed with Fe(III), A1, and U(IV); in weakly acid and neutral solutions, with rare-earth elements, Fe(II), Cu, Mn, and in alkaline solutions, with Ca, Sr, and Mg. Easily hydrolyzable species react in more acidic solutions, whereas other ions react only in less acidic ones. Reagents of the R-SH type react in acid solutions with cations of the second analytical group that form the most stable sulphides. In weakly acidic and neutral solutions they react with metal cations of the third analytical group.
44
3. Spectrophotometric methods
The acidity of the medium has an important influence on the form of certain ions in the solution (e.g., Zr, Ti, V) and this form is decisive for the kind of reaction (in the case of Zr: Zr 4+, ZrO 2+, polymerized forms). In the reactions of chemical species with some reagents, the optimum pH range may be narrow, either because of the maximum sensitivity of the colour reaction or the effect of other ions. The pH of coloured solutions is often stabilized by means of suitable buffers. Tartrate, citrate, phosphate and phthalate solutions are usually avoided since they can bind many metals in stable complexes. Acetate solutions are often used, although they also can form complexes with some metals (e.g., A1, Be). Acetate buffers may be replaced by hexamethylenetetramine buffers. An increase of selectivity is usually achieved by masking the interfering ions [33-36]. The masking consists in conversion of the interfering ion into a stable complex formed with the complexing agent added. Owing to this, the ion cannot participate in the colour reaction with the spectrophotometric reagent. Some most important masking reagents are presented in Table 3.1. High selectivity of spectrophotometric methods is achieved by choosing proper masking reagents and appropriate pH values. The stability of the complexes is not constant, but it varies depending on pH and other parameters, such as the concentration of masking agent and the presence of other complexing compounds. Table 3.1. The most common masking agents
Ba
Masking agent CN-, 82032, I, CI, NH3 F, acetate, tartrate, EDTA, OHS2-, OH CN-, CI, Br-, $2032 F, hydroxy acids EDTA, citrate, SO42
Be
F-, citrate, tartrate
Bi
citrate, EDTA, I EDTA, citrate, tartrate EDTA, CN, I-, tartrate F-, EDTA, citrate NH3, SCN, EDTA EDTA, tartrate, acetate NH3, ON, S2032, EDTA, citrate H3BO3,AI, Be, Ti F, PO43, EDTA, tartrate CN, $2032, phenantr. EDTA, tartrate, citrate oxalate, FI, CN, ClEDTA, CI-, citrate CI, SCN, NH3 EDTA, oxalate, tartrate
Element Ag AI As Au B
Ca Cd Ce Co Cr(lll) Cu F Fe(lll) Fe(ll) Ga Ge Hg In Ir Mg
,,
Element Mn Mo Nb Ni Os Pb Pd
Pt Rh Ru Sb Sc Sn Sr Ta Th Ti TI U V W Zn Zr
Masking agent oxalate, EDTA, citrate F, H202, citrate, EDTA F-, tartrate, H202 CN, EDTA, NH3 CN, SCN, Clacetate, I-, citrate, tartrate, EDTA, SO42CN-, I-, citrate, tartrate, EDTA, SO42I-, ON-, NO2-, NH3 CI-, citrate, tartrate CN, Cl tartrate, I-, S2, OH-, F Citrate, EDTA tart., OH-, S2, FSO42-, EDTA, citrate F-, citrate, tartrate F-, EDTA, citrate, acetate H202, F-, citrate CI, EDTA, citrate, tartrate F, CO32, H202, citrate H202, EDTA, FF, H202, tartrate, citrate CN, EDTA, OH-, NH3 F, oxalate, citrate, H202, PO43
Although the number of known specific reagents is rather small, there exist some methods based on the use of group reagents (that react with many elements), which in the presence of suitable masking agents and at proper pH have a specific action. Examples of such systems may be the determination of Zn with dithizone at pH 4-5 in the presence of
3.5. Colour systems
45
thiosulphate, or the determination of A1 with 8-hydroxyquinoline at pH 9 in the presence of EDTA, cyanide and H202 as masking agents. The selectivity of spectrophotometric methods has been greatly increased by the development of derivative spectrophotometry (see Chapter 1.5). Derivative spectrophotometry enables one to single out, by means of various mathematical algorithms of data processing, a separate signal due to a selected component, from the sum of absorbances of the analysed mixture. This technique was successfully applied in determinations of a number of elements in mixtures such as Pd, Pt and Au [37], Pd and Pt in iodide solutions [38], Au, Pd and Pt in bromide solutions [39], Ru(III) and Rh(III) in the form of octadecyldithiocarbamate complexes [40], Ru and Os in chloride solutions [41 ], Cu, Hg and Pb as dithizonates [42], complexes of various metals with 4-(2-pyridylazo)resorcinol [43], Fe(III) with EDTA in the presence of Cr(III), A1 and Mn [44], Cr(III) and Cu(II) with EDTA [45], and Cu and Co in a flow system [46]. Derivative spectrophotometry was also used in the study of Sr- complexing reactions with various crown ethers [47].
3.5. Colour systems Most of the colour systems, used as a basis of spectrophotometric methods are formed as a result of complexing reactions. The most important spectrophotometric reagents are presented in Chapter 4. A large group of the methods is based on difunctional organic reagents that with metal ions form inner chelates, soluble in non-polar solvents. Such reagents are generally used in the extraction-spectrophotometric methods involving, e.g., dithizone, dithiocarbamates, 8-hydroxyquinoline, 1-nitroso-2-naphthol, dioximes and PAN [1-(2pyridylazo)-2-naphthol]. Another group of methods is based on organic reagents giving electrically charged, water-soluble complexes. Such reagents comprise hydrophilic, mostly sulphonic groups. Such types of complexes are formed by arsenazo III, PAR [4-(2-pyridylazo)resorcinol], 5Br-PADAP [2-(5-Br-2-pyridylazo)-5-diethylaminophenol], Eriochrome Black T, Chrome Azurol S, and Bromopyrogallol Red. Cationic complexes of metals are formed in reactions with 1,10-phenanthroline or cuproin. A large group of sensitive methods is based on ternary systems[ 10,48]. Reactions of easily hydrolyzable metal ions [e.g., Be, A1, In, Sc, Ti, Th, Fe(III), Zr] with some chelating chromogenic reagents (e.g., CAS, ECR, phenylfluoron) give strongly coloured ternary complexes (with a large bathochromic shift of the order of 100-200 nm) in the presence of surfaetants [49-61]. Among the most often used cationic surfactants are bromide or chloride salts of cetyltrimethylammonium (CTA, formula 3.1) cetylpyridinium (CP, formula 3.2) and tetradecyldimethylbenzylammonium (Zephiramine, formula 3.3). CH3 C16H33--N--CH3
I
CH3
C.H3 (3.1)
C,6H33--
(3.2)
Clt.H29m
--CPI 2 CH3
An example of a non-ionic surfactant is Triton X-100 (octylphenyl polyethyleneglycol ether). Basic dyes (triphenylmethane, xanthene, azine, etc., dyes) form ion-association compounds (ion-pairs) with anionic halide complexes of metals and non-metals (e.g., SbC16-, AuBr4-, TaF6-, BF4-). The resulting compounds, that may be extracted into non-polar organic solvents, may serve as a basis for sensitive spectrophotometric methods [62-65].
46
3. Spectrophotometricmethods
Extractable ionic associates are also formed in reactions of heteropoly acids with basic dyes [62,66,67]. In some systems, more complex ionic associates are formed. These compounds are not extractable, but may form a basis for very sensitive flotationspectrophotometric methods [68,69]. Another group of methods is based on ionic associates formed by acid dyes (e.g., eosine, Bengal Rose, Methyl Orange) with hydrophobic cationic complexes of some metals [e.g., Fe(II), Ag(I), Zr, Cd] with 1,10-phenanthroline and other organic bases [10,62]. With metal ions, some organic reagents form coloured compounds that are sparingly soluble both in water and in organic solvents. They are either polynuclear complexes, such as formed by phenylfluoron with Sn(IV) or with Ge(IV), or adsorption-type compounds such as those formed by titanium yellow with Mg. In such cases, the absorbance is measured for suspensions of coloured pseudo-solutions stabilized with protective colloids [e.g., gum arabic, gelatine, poly(vinyl alcohol)]. Complexes of metal ions with inorganic reagents are also applied in spectrophotometric methods, e.g., thiocyanate [Fe(III), Co, Nb, Mo, Re, W, U, Ti], iodide (Bi, Sb, Pd), or hydrogen peroxide (Ti, V, U). Determinations based on such complexes are carried out in aqueous solutions or after extraction with oxygen-containing organic solvents. A group of elements (P, As, Si, Ge, V, W, Mo etc.) forms yellow heteropoly acids which, on being reduced, give intensely coloured blue compounds. Both the heteropoly acids and their reduced forms are used for determination of the elements. All these forms are extracted with oxygen-containing solvents. It should also be mentioned that the heteropoly acid anions form extractable ionic associates with basic dyes. Colour systems suitable for use in the spectrophotometric method may also be formed in redox reactions. Some examples of such reactions are: the oxidation of Mn(II) to MnO4or Cr(III) to CrO42-, oxidation of dimethylnaphthidine with vanadium(V) or chromium(VI), oxidation of o-tolidine with cerium(IV) or with chlorine. Examples of oxidation reactions are also the iodide methods, in which iodide ions are oxidized with bromine to give iodate ions which, in turn, react with the excess of iodide anions to form free iodine (see Chapter 25). A colour effect of reduction also occurs, for example, in determinations of Se and Te in the form of coloured sols produced in the reduction of Se(IV) or Te(IV) to their elementary forms. In some methods the colour system is a product of a synthesis reaction. Examples of such methods are: formation of an indophenol dye in a method for determination of ammonia, the synthesis of azo dyes in the determination of nitrite, the formation of Methylene Blue in the determination of sulphur, the pararosaniline method for determination of sulphite, and the benzidine-pyridine method for determination of cyanide. There are also indirect speetrophotometrie methods, in which the element determined provokes a change in colour. This group comprises most of the methods for the determination of fluoride. Being capable of forming stable complexes with some metals, fluoride anions can decompose colour complexes of those metals. Thus, in the method involving a sulphosalicylate complex of Fe(III) the solution is discoloured by F- and a change of colour is observed in the method based on the use of the Zr complex with ECR. Still another example is the determination of phosphate with the use of lanthanum chloranilate. Phosphate anions react to form the less soluble LaPO4 and release coloured chloranilate ions. Amplification methods [70-73], owing to their high sensitivity, are used in the determination of trace amounts of certain elements, including halides and some metals (e.g.,
Mo, Cr, Bi).
3.5. Colour systems
47
The development of a new spectrophotometric method is usually preceded by studies of the colour system (complex composition and stability), which is the basis of the method. Fundamental physicochemical studies of the colour complexes existing in the solution enable one to establish the optimum parameters of the method [74-76]. The composition of the complex (molar ratio of metal to ligand) in the solution is determined by Job's continuous variation method, the Bent and French method of equilibrium shift, the method of mole ratio proposed by Yoe and Jones, and the method based on the ratio of slopes and isosbestic points. Studies of complex compounds in solutions are described in many works, especially [77-80]. The role of mixed media (water and water-miscible organic solvents) in colour reactions which are useful in spectrophotometric methods has also been discussed [81 ]. Problems occurring in the development and publishing of new methods have also been considered [82.
3.6. Analytical procedure Spectrophotometric methods based on the use of calibration curves are comparative methods. Their accuracy depends to a considerable extent on the proper preparation of the standard solutions of the elements to be determined, which are used for the preparation of calibration graphs. Standard solutions are divided into stock and working solutions. Sufficiently concentrated stock solutions may usually be stored for a long time. More dilute working solutions, obtained by suitable dilution of stock solutions cannot, in general, be stored for a long time. Stock solutions, usually containing 1 mg of element (or ion) per ml less often, 10 mg/ml - - are obtained by dissolving sufficiently pure salts of definite composition. Water is used as a solvent, or dilute acids if the metal ions would hydrolyse or precipitate as carbonates with atmospheric carbon dioxide. The concentrations of the working solutions are related to the sensitivity of the spectrophotometric method: 0.1 rag, 10 ~tg, or 1 ~tg of element per ml. Solutions of concentration 10 ~tg/ml, and especially 1 ~tg/ml, are prepared freshly on the day of use. The instability with time, observed in more dilute working solutions, is mainly due to sorption of ions on the surface of the vessel [83,84]. When preparing standard working solutions it is best to conform with the rule of tenfold dilution and using adequately accurate pipettes and standard flasks (e.g., a 10 ml pipette and a 100 ml flask. From a solution of concentration 1 mg/ml one obtains a solution of 0.1 mg/ml and, in turn, 10 ~tg/ml. If there is no available salt of constant composition, such as copper(II) sulphate or iron(III), aluminium or chromium alums, it is advisable to prepare first a stock solution of an approximate concentration, slightly higher than required and to determine the concentration by a gravimetric or volumetric method. After suitable calculations the solution is diluted with pure solvent to obtain a solution containing exactly, e.g., 1 mg/ml of the given element. In some cases, standard solutions are obtained by dissolving a precisely weighed amount of the element in its pure form. Sometimes it is necessary for the standard solution to contain no complexing anions, and therefore a perchlorate or a nitrate is used. These can be obtained by starting with any other salt available (e.g., chloride, sulphate). The salt is dissolved in water or dilute acid, the metal is precipitated as hydroxide by means of ammonia or NaOH solution, and the
48
3. Spectrophotometricmethods
precipitate is filtered off, dissolved in perchloric or nitric acid, and diluted with water to a definite volume. In order to select the most suitable wavelength for the spectrophotometric measurements it is necessary to know the absorption spectrum of the complex, as well as that of the reagent if it is coloured. The absorption spectrum (absorption curve) is a plot of absorbance v s . wavelength. It is obtained with a recording spectrophotometer or plotted manually from measurements made on a non-recording instrument at 10-20 nm intervals, and at 2-5 nm intervals near the absorption maximum. The solvent is used as reference. The absorption spectra are drawn in the system: wavelength (~, in nm) as abscissa, and absorbance (A) or coefficient, e, as ordinate. When the analytical wavelength has been selected, on the basis of absorption spectra of the complex and the reagent, it is normal to prepare the standard curve. The absorbance measurements are usually made at ~max of the coloured compound. It can happen, when the complex and the reagent absorb in the same wavelength range, that the absorbance is measured not at the ~maโข but at a wavelength corresponding to a maximum difference between the absorbances of the complex and the reagent. The s t a n d a r d curve (calibration graph, analytical curve, calibration curve), relating the absorbance to the analyte concentration, is prepared by applying the colour reaction procedure to a set of standard solutions, regularly spaced over a concentration range that will give a maximum absorbance of 0.8-1.0. The conditions specified in the analytic procedure must be strictly adhered to. The curve is plotted with the scale arranged so that the curve is at about 45 o to the abscissa, as shown in Fig. 3.1.
0,8 0,6 O,t, 0,2
0
0,5
1,0
1,5 2.0 concentration
Fig. 3.1. Standard curve
The absorbances of standards and samples are measured in cuvettes of the same pathlengths, usually 1 or 2 cm, although 0.1-, 0.5-, and 4 cm cells are sometimes used. The choice of cuvette depends on the sensitivity of the method, the quantity of the analyte and the behaviour of the solution in relation to Beer's law. If, at low values of absorbance, deviations from Beer's law are observed, then the use of a longer pathway cuvette is recommended so that higher absorbance values are obtained for more dilute solutions. The reference (comparison) solution in one-colour spectrophotometric measurements is usually the solvent (if the reagent is colourless), and in two-colour methods a reagent solution is used. As well as the spectrophotometric reagent the reference should contain other reagents and have pH identical to the analyte solution. It happens that at ~max the absorbance of the colour reagent is zero and pure solvent may be applied as the reference.
49
References
3.7. Trace analysis Sensitive spectrophotometric methods are used in trace analysis either directly or after a preconcentration of the trace elements to be determined [ 10,85-88]. The value of the blank test plays an essential role in spectrophotometric analysis, especially when common elements are determined. The blank can serve as a reference in measurements of the absorbance. It also eliminates the effect of analyte admixtures introduced with the reagents, vessels or environment [89-94]. Blank determinations are made in parallel with measurements of analyte samples, and the results are obtained as the difference. Reducing the size of the blank permits the determination of smaller quantities of traces in the samples, especially for the more common elements such as Fe, Zn, Ca, Mg, A1, Si. The size of the blank can be reduced in various ways. The equipment used for sampling and for commination of the sample should be made, if possible, from material which does not contain the element to be determined. In some cases the admixtures can be removed by the use of an appropriate solvent, which does not react with the sample but dissolves the impurities (e.g., the use of hydrochloric acid to remove iron from a sample of silicon comminuted in a steel mortar). Quartz, polyethylene or Teflon vessels are used instead of glassware. To prevent contact of the sample with laboratory air, certain chemical operations may be conducted in closed chambers (dry boxes) flushed with purified air or inert gas [95, 96]. The reagents are the source of the major contaminants in the blank test. The water used should be distilled in a quartz apparatus after demineralisation with ion-exchangers [97]. Acids (H2SO4, HNO3, HC104, HC1, HBr) can be purified by slow distillation in quartz vessels. Hydrofluoric acid is purified by distillation in platinum or palladium vessels. Ammonia of high purity is obtained by saturation of distilled water with gaseous NH3. Reagents thus purified are kept in polyethylene bottles. Solutions of other reagents are usually purified by solvent extraction and coprecipitation with collectors. Some volatile reagents (hydrochloric acid, hydrobromic acid, ammonia) can be brought to a very high degree of purity by isothermal (isopiestic) distillation [98,99]. Iron(III) traces can be removed from concentrated hydrochloric and hydrobromic acids by passing the acids through a strongly basic anion-exchanger. For control of the accuracy in determination of traces of elements, standard reference materials are of great importance [100-106].
References 1. Charlot G., Dosages absorptiom~triques des ~l~ments min~raux, Masson, Paris 1978. 2. Boltz D.F., Howell J., Colorimetric Determination of Nonmetals, Wiley, New York 1978. 3. Marczenko Z., Spektrofotometryczne oznaczanie pierwiastk6w, PWN, Warszawa 1979. 4. Lange B., Vejde 1ek Z.J., Photometrische Analyse, Verl ag Chemie, Weinheim 1980. 5. Salakhov M.Kh., Zh. Prikl. Spektrosk., 47, 839 (1987). 6. Dubrovkin I.M., Zh. Anal. Khim., 43, 965 (1988). 7. Constant D., Analusis, 16, XXXII (1988). 8. Vandeginste B.G., Fresenius'J. Anal. Chem., 337, 786 (1990). 9. Gal lot S., Thomas O., Int. J. Environ. Anal. Chem., 52, 149 (1993). 10. Marczenko Z., Crit. Rev. Anal. Chem., 11, 195 (1981).
50
3. Spectrophotometricmethods
11. Marczenko Z., Separation and Spectrophotometric Determination of Elements, Horwood, Chichester 1986. 12. Onishi H., Photometric Determination of Traces of Metals, Part IIA: Aluminium to Lithium, Part liB: Magnesium to Zirconium, Wiley, New York 1986-1989. 13. Nemcova I., Cermakova L., Gasparic J., Spectrophotometric Reactions, Dekker, New York 1996. 14. Burns D.T.,Anal. Proc., 25, 253 (1988). 15. Denney R.C., Sinclair R., Visible and Ultraviolet Spectroscopy, J. Wiley & Sons, New York 1988. 16. Howell J.A., Hargis L.G.,Anal. Chem., 62, 155R (1990). 17. Kuzyakov Y.Y., Semenenko K.A., Zorov N.B., Spectral Analysis Methods, Moskovskii Gos. Univ., Moscow 1990. 18. Thomas O., Analusis, 19, 139 (1991). 19. Hargis L.G., Howel 1 J.A., Anal. Chem., 64, 66R (1992). 20. Lobifiski R., Marczenko Z., Crit. Rev. Anal. Chem., 23, 55 (1992). 21. Hargis L.G., Howell J.A., Visible and Ultraviolet Spectrophotometry, in Physical Methods in Chemistry, Rossiter B.W., Baetzo 1d R.C., (Eds.) J. Wil ey & Sons, New York 1993. 22. Howell J.A., Hargis L.G., Anal. Chem., 66, 445R (1994). 23. Hargis L.G., Howell J.A., Sutton R.E., Anal. Chem., 68, 169R (1996). 24. George W.O., Willis H.A., Computer Methods in UV; VIS and IR Spectroscopy, Royal Society of Chemistry, Cambridge 1990. 25. Laqua K., Melhuish W.H., Zander M., Pure Appl. Chem., 60, 1449 (1988). 26. Ayres G.H., Narang B.D., Anal. Chim. Acta, 24, 241 (1961). 27. Lingane P.J., Anal. Chim.Acta, 47, 529 (1969). 28. Rothman L.D., Crouch S.R., Ingle J.D.,Anal. Chem., 47, 1226 (1975). 29. Ingle J.D.,Anal. Chim. Acta, 88, 131 (1977). 30. Cuadros Rodriguez L., Garcia Campana A.M., Jimenz Linarez C., Roman Ceba M., Anal. Lett., 26, 1243 (1993). 31. Fasanmade A.A.,Anal. Lett., 27, 1955 (1994). 32. Kubinyi H., Trends Anal. Chem., 14, 199 (1995). 33. Hulanicki A., Talanta, 9, 549 (1962). 34. Perrin D.D., Crit. Rev. Anal. Chem., 5, 85 (1975). 35. Pyatnitskii I.V., Zavod. Lab., 51, No 3, 3 (1985). 36. Kotov A.V., Zh. Anal. Khim., 43, 937 (1988). 37. Kuroda R., Hayashibe Y., Yoshitsuka K., Fresenius'J. Anal. Chem., 336, 494 (1990). 38. Marczenko Z., Obarski N., Chem. Anal. (Warsaw), 39, 347 (1994). 39. Obarski N., Marczenko Z., Chem. Anal. (Warsaw), 40, 385 (1995). 40. Malathi K., Subbaiyan M., Talanta, 42, 1487 (1995). 41. Balcerzak M., Swi~cicka E., Talanta, 43, 471 (1996). 42. Mathew L., Prasada Rao T., Iyer C.S., Damodaran A.D., Mikrochim. Acta, 118, 249 (1995). 43. Bobrowska-Grzesik E., Grossman A.H., Fresenius' J. Anal. Chem., 354, 498 (1996). 44. Salem H., E1-Maamli M., E1-Sadek M., Kheir A.A., Zh. Prikl. Spektrosk., 57, 264 (1992). 45. Seco-Lago H. et al., Fresenius' J. Anal. Chem., 357, 464 (1997). 46. Vereda E., Rios A., Valcarcel M., Analyst, 122, 85 (1997). 47. Mateeva N., Antonov L., Miteva M., Miteva S., Talanta, 43, 275 (1996). 48. Ostrovskaya M.S. et al., Zavod. Lab., 46, 97 (1980).
References
51
49. Tikhonov V. N., Zh. Anal. Khim., 32, 1435 (1977). 50. Chernova R.K., Zh. Anal. Khim., 32, 1477 (1977). 51. Chernova R.K. et al., Zh. Anal. Khim., 33, 858 (1978). 52. Savvin S.B., Chernova R.K. et al., Zh. Anal. Khim., 33, 1473 (1978). 53. Nemodruk A.A. et al., Zh. Anal. Khim., 34, 1266 (1979). 54. Tikhonov V.N., Aleksandrova N.L., Zh. Anal. Khim., 36, 242 (1981). 55. Tikhonov V.N., Pavlova O.K., Zh. Anal. Khim., 37, 1809 (1982). 56. Tikhonov V.N. et al., Zh. Anal. Khim., 38, 216 (1983). 57. Chernova R.K. et al., Zh. Anal. Khim., 39, 1019 (1984). 58. Tananayko M.M. et al., Zh. Anal. Khim., 39, 1034 (1984). 59. Callahan J.H., Cook K.D.,Anal. Chem., 56, 1632 (1984). 60. Antonovich V.P., Novoselova M.M., Nazarenko V.A., Zh. Anal. Khim., 39, 1157 (1984). 61. Jarosz M., Marczenko Z., Chem. Anal. (Warsaw), 37, 63 (1992). 62. Marczenko Z., Mikrochim. Acta, 1977 II, 651. 63. Motomizu S., Fujiwara S., T6ei K., Anal. Chim. Acta, 128, 185 (1981). 64. T6ei K., Anal. Sci., 3, 479 (1987). 65. Balog I.S., Kish P.P., Bagreev V.V., Zh. Anal. Khim., 43, 1750 (1988). 66. Alimarin I.P. et al., Zh. Anal. Khim., 39, 965 (1984). 67. Lychnikov D.S., Dorokhova E.N., Gracheva N.A., Zh. Anal. Khim., 43, 802 (1988). 68. Marczenko Z., Pure Appl. Chem., 57, 849 (1985). 69. Marczenko Z., Kalinowski K., Chem. Anal. (Warsaw); 32, 451 (1987). 70. Belcher R., Talanta, 15, 357 (1968); 24, 533 (1977). 71. Weisz H., Fritsche U., Mikrochim. Acta, 19"/3, 361" 1974, 701. 72. Flaschka H.A., Hornstein J.V., Microchem. J., 23, 488 (1978). 73. Burns D.T., Townshend A., Talanta, 39, 715 (1992). 74. McBryde W.A., Talanta, 21,979 (1974). 75. Sommer L., Kuba_ V., Langov~ M., Z. Anal. Chem., 310, 51 (1982). 76. Sommer L., Langova M., Crit. Rev. Anal. Chem., 19, 225 (1988). 77. Klausen K.S., Langmyhr F.J.,Anal. Chim. Acta, 40, 167 (1968). 78. Klausen K.S., Anal. Chim. Acta, 44, 377 (1969). 79. Likussar W., Boltz D.F., Anal. Chem., 43, 1265 (1971). 80. Ringbom A., Harju L., Anal. Chim. Acta, 59, 33, 49 (1972). 81. Petrova T.V., Savvin S.B., Zh. Anal. Khim., 42, 1925 (1987). 82. Kirkbright G.F., Pure Appl. Chem., 50, 237 (1978). 83. Struempler A.W.,Anal. Chem., 45, 2251 (1973). 84. A1-Sibaai A.A., Fogg A.G.,Analyst, 98, 732 (1973). 85. Nazarenko V.A., Flyantikova G.V., Zh. Anal. Khim., 32, 1217 (1977). 86. Sandell E.B., Onishi H., Photometric Determination of Traces of Metals. General Aspects (Chapters 1--4), Wiley, New York 1978. 87. Zolotov Yu.A., Kuz'min N.M., Preconcentration of Trace Elements, Elsevier, Amsterdam 1990. 88. Lobifiski R., Marczenko Z., Spectrochemical Trace Analysis for Metals and Metalloids, Elsevier, Amsterdam 1996. 89. Robertson D.E., Anal. Chem., 40, 1067 (1968). 90. Kloster M.B., Hach C.C., Anal. Chem., 44, 1061 (1972). 91. Mizuike A., Pinta M., Pure Appl. Chem., 50, 1519 (1978). 92. T61g G., Pure Appl. Chem., 50, 1075 (1978). 93. T61g G., Z. Anal. Chem., 294, 1 (1979).
52
3. Spectrophotometricmethods
94. Kosta L., Talanta, 29, 985 (1982). 95. Zief M., Mitchell J.W., Contamination Control in Trace Element Analysis, Wiley, New York 1976. 96. Van Grieken R., Van de Velde R., Robberecht H.,Anal. Chim. Acta, 118, 137 (1980). 97. Petrick H.J., Schulze F.W., Cammenga H.K., Mikrochim. Acta, 1981 II, 277. 98. Kuehner E.C., Alvarez R., Paulsen P.J., Murphy T.J., Anal. Chem., 44, 2050 (1972). 99. Rovinskii F.Ya., Gasilina N.K., Zh. Anal. Khim., 33, 160 (1978). 100. Knowles A., Burgess C., Standards in Absorption Spectrophotometry, Chapman-Hall, London 1981. 101. Cali J.P.,Anal. Chem., 48, 802A (1976); Z. Anal. Chem., 297, 1 (1979). 102. Koch O.G., Pure Appl. Chem., 50, 1531, 1951 (1978). 103. Quevauviller E.A., Maier E.A., Griepink B., Anal. Chim. Acta, 283, 583 (1993). 104. Michalke B., Fresenius'J. Anal. Chem., 350, 2 (1994). 105. Caroli S.,Anal. Chim. Acta, 283, 573 (1993). 106. Kuselman I., Talanta, 40, 1 (1993).
Chapter 4. Spectrophotometric reagents Reagents which give the colour reactions, upon which spectrophotometric methods are based, are called spectrophotometric reagents. Most spectrophotometric methods are based on organic reagents [1-4]. The theory of organic reagents, the mechanism of their reactions with metal ions, the structure of the complexes formed, and the effect of the dissociation constants and of the reagents and of hydrolysis constants of metal ions upon the formation of complexes have been presented in publications [5,6]. A historical survey of the organic reagents has been given [7]. A review of reagents used for determination of inorganic species has also been published [8,9]. This Section deals with the more important groups of spectrophotometric reagents. Some important reagents are presented, with formulas, in chapters devoted to individual elements.
4.1. Azo reagents The azo reagents form a large group of spectrophotometric organic reagents. This group comprises such reagents as 1-(2-pyridylazo)-2-naphthol (PAN), 4-(2-pyridylazo)resorcinol, (PAR), 5-Br-PADAP, Arsenazo III and Chlorophosphonazo III. Methods using azo dyes are sensitive.
4.1.1. N-Heterocyclic azo compounds Pyridylazo- and thiazolylazo reagents have become of great importance in the methods of determination of metals [ 10,11 ]. 1-(2-pyridylazo)-2-naphthol (PAN) (formula 4.1) can exist in solutions in three forms, depending on the pH. Acid solutions (pH < 2) contain the water-soluble yellow-green protonated HzR+ ion. Between pH 3 and 11, PAN occurs as the neutral HR molecule, soluble in organic solvents to give a yellow colour (colloidal suspensions can be formed in aqueous systems). In alkaline solutions of pH > 11 PAN exists as the water-soluble red R ~anion.
OH PAN is normally used in methanol or ethanol solutions. It acts as a terdentate ligand, complexing with metals through the hydroxyl oxygen atom, pyridine nitrogen atom, and one of the azo group nitrogen atoms. Metal complexes with PAN are sparingly soluble in water. Metal ions form neutral complexes extractable with inert solvents, such as chloroform or benzene. This permits the extractive-spectrophotometric determination of Mn, Zn, Cd, Cu, Ni, Co, In, U, Ga and Pd [12-14]. The molar absorptivities of the PAN complexes lie within
54
4. Spectrophotometric reagents
the range (2-6). 104. During extraction with an organic solvent, the metal complex and the uncombined PAN pass to the extract. The absorption maxima ~max of the complexes are usually very different from that of the reagent. The selectivity of the methods using PAN is enhanced by suitable selection of pH and masking agents. Iron, cobalt, and nickel, for example, react with PAN at pH = 4. At such a low pH the reagent does not form complexes with Mn, Zn and Cd. Cyanide enables manganese to be determined in the presence of Ni, Zn, Cd, Co, and Cu, which form stable cyanide complexes. Zinc and cadmium can be demasked from their cyanide complexes with formaldehyde. Unlike PAN, 4-(2-pyridylazo)resoreinol (PAR) (formula 4.2) is water-soluble and forms water-soluble complexes with metal ions [15,16]. In the range from 90% H2SO4 to pH 2 the following protonated forms are present: HsR 3+, H4R 2+ and H3R+. The neutral PAR molecule exists between pH 2.1 and 4.2 (~,max 385 nm). The anion HR- (~max 413 nm) occurs over the pH range 4.2-7. In alkaline solutions (pH 11-13) both hydroxyl groups are dissociated. The R 2- form has ~max 490 nm.
(4.2) OH
PAR gives coloured complexes with metal ions. The determination of metals with PAR is performed in aqueous solutions. In 0.5-0.05 M H2804 the reagent reacts with Cu, Bi, Ti, Zr, Pd, and TI(III) ions. In acetate medium (pH 3-6) PAR gives colour reactions with Zn, Cd, Co, Ni, Hg, U, Pb and Ga. Solutions of PAR complexes have a red or violet colour. Complexes of PAR with Co, Ni, Cu, Zn, and Cd can be extracted into chloroform in the presence of diphenylguanidine [ 17]. The bromo- and ehloro-derivatives pyridylazo derivatives [18-21] are very valuable, because they form the basis of highly sensitive methods. Their complexes with metal ions have molar absorptivities e about 105. The most widely applied 2-(5-bromo-2-pyridylazo)-5diethylaminophenol (5-Br-PADAP) (formula 4.3) has become the basis for very sensitive methods of determination of Cd, Co, Ni and other metals.
<4>
N.~-----.
(4.3)
NICzI..Is) 2
/
HO
CI,,
(4.4) HO
(4.5) HzN
Other examples of reagents of this group are: 2-(5-chloro-2-pyridylazo)-5diethylaminophenol (5-C1-PADAP) (formula 4.4), 4- (5-bromo-2-pyridylazo)- 1,3-
4.1. Azo reagents
55
diaminobenzene (5-Br-PADAB) (formula 4.5) and 2-(3,5-dibromo-2-pyridylazo)-5diethylaminophenol (3,5-diBr-PADAP) used in determinations of U and Zr. Thiazole azo compounds have similar properties to PAN and PAR as spectrophotometric reagents. Their reactions with metals are more selective, principally as a consequence of the lower stability of their complexes. The following reagents are examples: 1-(2-thiazolylazo)-2-naphthol (TAN) [22] (formula 4.6) and 4-thiazolylazo)resorcinol (TAR) [23, 24] (formula 4.7).
s
I
s
o.
(4.6)
(4.7)
A comprehensive review on applications of thiazolylazo reagents in spectrophotometric methods has been given [25].
4.1.2. Arsonic azo compounds The first reagents of this group were Arsenazo I (formula 4.8) and Thoron I (formula 4.9). This group of reagents is characterized by the presence of an arsonic acid group ortho to the azo group. The hydroxyl group is usually also ortho to the azo group. AsO3Hz
(4.8)
HO
S03H
(4.9)
The presence of the arsonic acid group, AsO3H2, causes the formation of stable complexes of some metals even in fairly strong acid solutions. The presence of the azo group ensures the colour reaction, whereas the hydroxyl group enables a second ring to be formed with the metal. This not only stabilizes the complex but also causes a considerable deepening of the colour obtained. The sulphonic acid groups render these reagents and their complexes watersoluble. Until Arsenazo I and related reagents were introduced into spectrophotometric analysis, there were no sensitive reagents for such elements as Th, Zr, Hf, U, and rare earths. Arsenazo I and a number of its analogues are derivatives of chromotropic acid (1,8dihydroxynaphthalene-3,6-disulphonic acid). Arsenazo I is applied to the determination of rare earths, Th, U, Zr, Ti, Nb, and other metals. Thoron I is less sensitive but more selective than Arsenazo I. It is most commonly applied to the determination of thorium and also Li, U, Zr and Be.
56
4. Spectrophotometric reagents
Arsenazo III (formula 4.10) is a very useful bis-azo dye based on chromotropic acid and o-aminophenylarsonic acid. It is moderately soluble in neutral and acid solutions, and readily soluble in slightly alkaline solutions. Strong oxidizing (H202, C12, Br2) and strong reducing agents (e.g., TIC13) cause decomposition. In acid solutions (from 10 M hydrochloric acid to pH 4) Arsenazo III has a purplish-red colour, while at higher pH values it is blueviolet.
~~__ s03Hz
H0
OH
HzO~As
(4.10) In strongly acid solutions (1-10 M HC1) Arsenazo III reacts only with Th, Zr, Hf and U(IV). The molar absorptivities, e, of the complexes with these metals are about 105. At pH 1-4 Arsenazo HI reacts with U(VI), Sc, Fe(III), Bi, and rare earths. The sensitivity of the colour reactions is lower in this case (e -5-104). The use of Arsenazo III in strongly acid medium overcomes difficulties connected with the hydrolysis of some multivalent metals (e.g., Zr, Th, U). In the determination of these metals the high acidity enhances the selectivity of the reagent. The absorbance of free Arsenazo III (~max 520-530 nm) at the absorption maxima of the metal complexes (~ 655-665 nm) is very slight. The large difference (A~) between the wavelengths of the absorption maximums of the complexes and the free reagent is important. In the case of Th and U the spectrophotometric method with Arsenazo HI is specific owing to the use of masking agents (oxalic acid, HF) and an appropriate acidity of the medium. Only one side of the symmetrical molecule Arsenazo III participates in the formation of complexes with metal ions. The metal ion bonds to the nitrogen atom of the azo group, the oxygen atom of the arsonic acid group, and the oxygen atom of the hydroxyl group. The distortion of the symmetry of the reagent molecule gives rise to two neighbouring absorption maxima in the visible spectra of the Arsenazo III metal complexes. It is possible to determine Arsenazo III by measuring its absorbance in concentrated sulphuric acid medium at 675 nm. Arsenazo I does not absorb under these conditions. The synthesis conditions and properties of high-purity Arsenazo III have been discussed [28-31 ]. A large number of other spectrophotometric reagents containing arsonic acid groups have been suggested. The reagents and their applications are critically reviewed [27,32,33]. The solubility and mechanism of reactions of these reagents have been discussed [34]. A related group of reagents comprises azo dyes containing phosphonic acid groups, for example, the Chlorophosphonazo HI (formula 4.11). This reagent is recommended for determinations of Zr, Ti, U, Sc, Ca, and Sr, among others [27].
P03Hz
H0
OH
Hz03 P~
(4.11) HO3S'"
v
~ f
"SO3H
4.1. Azo reagents
57
4.1.3. Other Azo Reagents Many azo reagents of other classes, such as o,o'-dihydroxyarylazo compounds have been employed in spectrophotometric determinations of various metals An example of the latter group of reagents is Sulphochlorophenol S (formula 4.12), which is recommended for determining such elements as Nb, Zr, Mo, Cu, V, and A1 in acid media [27].
HO3S~ - H -O ~OH HO \ /S03H N~N ' N=N--~ CI/ ....
H03S / ' w ~ / * ~ V J ~ ' ~ S
03H
(4.12)
\CI
An analogue of Sulphochlorophenol S is Sulphonitrophenol M, with nitro groups substituted for the two chlorine atoms of the former compound. This reagent has been applied for determination of Pb, Nb, A1, Ga, Zr, and V. Other examples of o,o'dihydroxyarylazo reagents are: Picramine-epsilon (formula 4.13) and the known reagents for determination of magnesium, namely Eriochrome Black T and Calmagite. OzN
OH
HO
S03H
(4.~3)
OzN
H03S
Examples of o-hydroxyarylazo compounds are: Chromotrope 2B (formula 4.14), a reagent for thorium and rare-earth elements, and 2-(4-sulphophenylazo)chromotropic acid (SPADNS) (formula 4.15) used in determinations of A1, Zn, Th, U and other metals [35]. In both these groups of azo reagents the oxygen atom of the o-hydroxyl group and the nitrogen atom of the azo group participate in complex formation with metal ions.
HO
OH
(4.14)
HO
OH
(4.15)
The presence of the sulphonic acid group in the azo reagents makes these and their complexes soluble in aqueous solutions. These complexes can be extracted in the presence of Aliquat 336 or tetrahexylammonium iodide in chloroform [36]. The sensitivity of reactions with azo reagents increases in the presence of organic solvents, such as acetone, propanol, or acetic acid [37]. 8-Hydroxyquinoline azo derivatives [38], pyrocatechol azo derivatives [39], and othiazo derivatives of p-cresol and 2-naphthol [ 4 0 ] have been reviewed.
58
4. Spectrophotometricreagents
4.2. Triphenylmethane reagents Owing to the presence of p-quinonoid tings triphenylmethane reagents are intensely coloured and provide the basis of spectrophotometric methods for the determination of a number of metals. Pyrocatechol Violet (formula 4.16) is a frequently used chelating reagent, readily soluble in water and in aqueous ethanol. An aqueous solution of the reagent is yellow (pH 18), and the colour of the solution changes to violet with increasing pH as a result of proton dissociation from the hydroxyl groups. Pyrocatechol Violet forms coloured (most often blue) chelates with many metals (e.g., Be, A1, Bi, Co, Cu, Fe, Ga, In, Mn, Pb, V, Zn) in weakly acidic and weakly basic solutions. OH
OH
(4.16) SO3'H
Eriochrome Cyanine R (ECR) (formula 4.17) and Chrome Azurol S (CAS) (formula 4.18) have carboxylate groups besides hydroxyl and sulphonate groups [41,42]. These reagents can be purified by various methods [43,44]. ECR and CAS react with many metals in weakly acidic or neutral solutions [45-47]. The yellow-orange colour of the reagents changes to blue or violet solutions of the metal chelates. C.H3
HOOC"" v
C,H3
"C~
+
~
C'H3
"COOH
HO0
SO~H
C'H3
C
I
(4.17)
OOH
(4.18)
Xylenol Orange (formula 4.19) [48,49] and its relative Methylthymol Blue [48,50] are characterized by the presence of the iminodiacetic acid groups, which occur in complexones such as EDTA. CH3
CH3
HOOCHzC HOOCI.IzC/'''~zu
CHzCOOH
S03H
~CHzCOOH
(4.19)
These reagents can be purified by various methods [51-53]. They are usually contaminated with unchanged starting materials and with products containing only one
4.3. Xanthene reagents
59
iminodiacetic group (e.g., Semi-Xylenol Orange). This group comprises also the Metalphthalein, used in determinations of Sr and Ba. Surface-active substances, cationic (CTA, CP, Zephiramine) (formulae 3.1, 3.2, 3.3) and non-ionic (e.g., Triton X-100) surfactants make it easier to dissociate the protons of chelating triphenylmethane reagents and, in consequence, facilitate the reactions of these chromogenic reagents (R) with easily hydrolysable metals [Be, A1, Ga, In, Fe(III), Sc, Ti, Zr] [54-61]. Ternary complexes are formed, with hyperchromic (increase of absorbance) and pronounced bathochromic (shift of ~max towards longer wavelengths) effects. In these complexes the ratio R:M. is higher than in binary systems (without surfactants). The mechanism of colour reactions involving surfactants was an object of studies that have led to fairly differing hypotheses. An important feature is the formation of surfactant micelles at considerable concentrations and appropriate pH values. In the determination of metals, values exceeding 105 are attained.
4.3. Xanthene reagents Among most frequently used chelating xanthene reagents are: Gallein (formula 4.20) [62], Bremepyregallel Red (formula 4.21) [63], and Pyregallel Red [63,64]. Xanthene reagents form chelates with many metals, such as Bi, In, Mo, Sn, Sb, Th, Ti, and Zr. The sensitivity of the determination methods increases in the presence of cationic surfactants [65]. OH
v
OH
OH
"C~" ~
B(
(4.20)
v
OH
-C=,-
v
"Br
(4.21)
Caleein (Fluorexone, Fluorescein Complexone) (formula 4.22), used as reagent for the determination of calcium, contains iminodiacetic acid groups in positions 2 and 7, and only one hydroxyl group in position 3. In the case of Calcein (like Xylenol Orange), the nitrogen atom of the iminodiacetic acid group participates in bonding the metal ion.
HO.~
0
~
~
O
HOOCHtC ~ N H z C ~ C ~ C I . . ~ N HOOCHzC/ COOH
CH2COOH / ~CHzCOOH
(4.22)
60
4. Spectrophotometric reagents
(4.23)
Another group of chelating xanthene reagents comprises 2,3,7-trihydroxy-6-fluorones, called simply fluorones [66]. The most often used reagents of this group are phenylfluorone (reagent for Ge and Sn) (formula 4.23) and methylfluorone, used for determination of Sb. Among more commonly known fluorones are salicylfluorone (formula 4.24 and disulfophenylfluorone (formula 4.25).
S03H
(4.24)
(4.25)
The sensitivity and the selectivity of the methods involving 2,3,7-trihydroxy-6-fluorones increase markedly in the presence of surfactants [67].
4.4. Non-chelating organic reagents 4.4.1. Basic dyes A number of elements give anionic complexes with halide and other ligands. These complexes can form ion-associates (ion pairs) with basic dyes, and are extractable into nonpolar solvents. The extracts form the basis of sensitive extraction-spectrophotometric methods [68,69]. The basic dyes are generally used as their halide salts. The form in which the dye can form the ion-association compound is its singly-charged cation. The solvents most often used are benzene, toluene, chloroform, and 1,2-dichloroethane. Sometimes a small amount of a donor-active oxygen-containing solvent (e.g., MIBK, butanol, di-isopropyl ether) is added to enhance the extraction. The acidity of the aqueous phase can vary over a wide range, from moderately concentrated mineral acid solutions (HC1, H2SO4) to pH 3-5, depending on the basic dye and the extraction solvent used.
4.4. Non-chelatingorganic reagents
61
Triaryhnethane (most often triphenylmethane) dyes constitute the most numerous group. The main representatives are Malachite Green, Brilliant Green (C2H5 instead of CH3 group) (formula 4.26) Crystal Violet (formula 4.27) and Methyl Violet [NHCH3 instead of N(CH3)2 on one benzene ring]. This group of dyes also includes Fuchsine (formula 27.1).
(CH3)zN~ .~NICH3)z -C~
(CzHs]zN~ ~N(CzHsIz
+
4-
V
- C ~'-
v
v
N(CH3] 2 (4.26)
(4.27)
The diphenylnaphthylmethane dyes comprise Victoria Blue 4R (formula 4.28) and Victoria Blue B (H instead of CH3 on the naphthyl group). Figure 4.1 shows the absorption spectra of some triarylmethane basic dyes.
(CH3)zN,~ ,~N(CH3lz +
C (4.28)
H3C//'N~csHs 2
500
600 . 6&O,
wavelength, nm
700
Fig. 4.1. Absorption spectra of Brilliant Green (1), Crystal Violet (2) and Victoria Blue 4R (3)
The theory of extraction of the ion-associates of basic triarylmethane dyes with complex anions has been discussed [70,71 ].
62
4. Spectrophotometric reagents
Rhodamine B (formula 4.29) is a xanthene basic dye [72]. Other reagents in this class are Rhodamine 3B (Ethyl Rhodamine B) (the ethyl ester of Rhodamine B) [73], Butyl Rhodamine B (the butyl ester) and Rhodamine 6G (formula 4.30).
CzHsNH~0~IHCzHs
4-
H3C" ~
(4.29)
~ "13
+
CH3 C00CzHs
(4.30)
The existence of several protonated forms of rhodamine dyes in acid solutions has been established [74]. Figure 4.2 shows the absorption spectra of xanthene basic dyes. The azine basic dyes are often applied in the spectrophotometric methods. Methylene Blue (formula 48.1) and Methylene Green are thiazine dyes.
2 rJ3
., 1
~00
530
S~176
nm6~176
Fig. 4.2. Absorption spectra of Rhodamine B (1) and Rhodamine 6G (2) (CzHs)zN-~~o~ICH3)z 4"
,,..u3P-"
v
~ 1 ~-
(4.31)
v
(4.32)
(4.33)
Among oxazine dyes are: Capri Blue (formula 4.31), Nile Blue A (formula 4.32) and Mendola's Blue. Safranine T [75] represents a phenazine dye (formula 4.33). The absorption spectra of the three azine dyes are presented in Fig. 4.3.
63
4.4. Non-chelating organic reagents
!
I
600
500
wavelength, nm
7O0
Fig. 4.3. Absorption spectra of Methylene Blue (1), Capri Blue (2) and Safranine T (3) Other types of basic dyes proposed for spectrophotometric determination of elements include the antipyrine dyes (Chrompyrazoles) [76,77], azo dyes [78], and the indamine dye Bindschedler' s Green (formula 30.1).
4.4.2. Acid dyes Acid dyes are used less frequently in spectrophotometric methods than the basic ones. Acid dyes form extractable ion-associates with hydrophobic cationic metal complexes. The dyes used are generally acid-base indicators. The acid xanthene dyes comprise Eosin (tetrabromofluorescein, formula 4.34) [79,80], Erythrosin (tetraiodofluorescein) and Rose Bengal B (formula 4.35) [79]. All these reagents are available as sodium salts. Br
Br
I
Cl"
(4.34)
I
y CI
"CI
(4.35) Br
Br
(4.36) S03H
64
4. Spectrophotometricreagents
Of the azo dyes, Methyl Orange has been successfully applied. The formula (4.36) shows the acid triphenylmethane dye, Bromophenol Blue (tetrabromophenolsulphophthalein) [81,82]. The cationic complexes which form ion-association compounds with acid nonchelating dyes are most commonly those of Zn, Cd, Pd, Fe(II), Cu with 1,10-phenanthroline. The e values often exceed 5.104. Chloroform and toluene are the commonly used extractants. As in the case of basic dyes, simple salts of acid dyes (e.g., sodium salts) are practically not extracted.
4.5. Dithizone Dithizone (HzDz, diphenylthiocarbazone, 3-mercapto-l,5-diphenylformazane) is one of the foremost organic spectrophotometric reagents [83-85]. It provides the basis of sensitive methods for the determination of Pb, Zn, Cd, Ag, Pd, Hg, Cu, Bi, and other metals. It has often been used in the extractive separation of traces of metals before their determination. Dithizone is insoluble in aqueous solutions at pH <7. It dissolves in alkaline media, forming an orange solution of HDz- anions. Dithizone dissolves, giving green solutions, in CC14, CHC13, hydrocarbons, and alcohols. The two tautomeric forms of dithizone: keto (I) and enol (II) (formula 1.1) co-exist in organic solvents [86]. The conditions for formation of dithizone complexes with individual metals are outlined in the sections dealing with the elements concerned. A primary or secondary* dithizonate is obtained, depending on whether the dithizonate reacts as the anion of the monobasic acid (HDz-) or the dibasic acid (Oz2-). Secondary dithizonates are formed by only a few metals. They are represented by such formulae as AgzDz and CuDz. Generally, acidic media and excess of dithizone favour the formation of primary dithizonates, whereas in alkaline media, and with insufficient amounts of the reagent, secondary dithizonates are formed. Investigations of the structures of primary dithizonates [89] have shown the metal to be bonded to the sulphur atoms by replacement of the hydrogen in the thiol group, and also coordinately bonded to a nitrogen atom, according to the formula 4.38 (for M2+).
9
N~ N
!
\~/
.S--C~N--NH-~"~
I
(4.38)
d The solubility of metal dithizonates, like that of dithizone itself, is higher in CHC13 than in CC14 (10-3-10-4 M): Cd(HDz)2 and Pb(HDz)2 are among the dithizonates most sparingly soluble in CC14.
*In the opinion of some authors [87,88] secondary dithizonates do not exist. In alkaline or acidic media, in the presence of excess of metal ions, mixed-ligandcomplexes are formed, e.g. HgCI(HDz) or Cu(OH)(HDz), where HDz- is the dithizone anion.These authors negate the possibility of existence of Dze- anion.
4.5. Dithizone
65
Solutions of metal dithizonates in organic solvents are intensely coloured, their colour differing considerably from that of dithizone. An exception is the grey-green solution of Pd(HDz)2. Figure 4.4 shows the absorption spectra of dithizone and several dithizonates dissolved in CC14. The presence of CHC13 admixtures in carbon tetrachloride affects the molar absorptivity of dithizone [90]. The most stable dithizonates (those of Pt, Pd, Au, Ag, Hg, and Cu) can be extracted from strongly acid solutions. Some metals (Bi, In, Zn) are extractable from weakly acid media, whereas other metals (Co, Ni, Pb, T1, Cd) are extractable from neutral or alkaline media. The higher the excess of dithizone, the lower is the pH at which the dithizonate forms. The pH at which extraction of individual metals starts is approximately 1.5 pH units higher with dithizone in chloroform than with dithizone in carbon tetrachloride.
./"
1
0
.'t, r ",,, .
4t:)0 '
462
500
,. !
550
\,.\ --
600
700
wavelength, nm
Fig. 4.4. Absorption spectra of dithizone (H2Dz) (1) and dithizonates: Cu(HDz)2 (2);, Pb(HDz)2 (3); Bi(HDz)3 (4); and AgHDz (5) in CCI4
Irrespective of their thermodynamic stability, the dithizonates of certain metals (e.g., Ag, Hg, Pb, Cd) are extracted rapidly, whereas those of other metals (Pd, Cu, Zn) require prolonged shaking with the organic solution of dithizone. This is explicable in terms of the kinetics of dithizonate formation [91]. The dithizonates of some metals (e.g., mercury) in CC14 or CHC13 change colour under the action of sunlight [92]. Selectivity in spectrophotometric methods for determining metals with dithizone is attained by controlling the acidity of the medium and using masking agents such as cyanide, EDTA, thiosulphate, or iodide. The most frequently applied method for determining metals with dithizone consists in extracting the metal from aqueous solutions with an excess of dithizone solution in CC14 (CHC13), removing the free dithizone from the non-aqueous phase by shaking with an alkaline aqueous solution, and measuring the absorbance of the coloured metal dithizonate solution. Atmospheric oxygen and other oxidants oxidize dithizone to diphenylthiocarbodiazone which, unlike dithizone, is insoluble in aqueous alkaline solutions, but soluble in CC14 and CHC13, giving a brown solution. This compound is chemically inactive. Commercial dithizone preparations are always contaminated with the oxidation products. The active dithizone content of a reagent preparation diminishes with time. When
66
4. Spectrophotometricreagents
preparing a dithizone solution, the oxidized product is separated, making use of the fact that diphenylthiocarbodiazone is insoluble in ammonia. (For the preparation of dithizone see section 46.2.1). Pure stable, solid dithizone may be obtained as follows. The reagent (0.5 g) is dissolved in 50 ml CHC13, and the solution filtered through a sintered glass filter. The solution is shaken in a separating funnel with two 10-ml portions of diluted aqueous ammonia (1 + 100). The ammoniacal extracts are separated from the brown chloroform layer and acidified with dilute hydrochloric acid to precipitate the dithizone, which is then extracted with small portions of pure CHC13. The extract is shaken with two portions of water, then placed in a beaker and the solvent is evaporated off in a water-bath at about 50 ~ Carbon tetrachloride and chloroform are the normal solvents for dithizone. Its solubility is greater in CHC13 (1 g / 1 0 0 ml) than in CC14 (0.08 g/100 ml). Unless otherwise stated, carbon tetrachloride is preferable as a solvent because of its lower volatility and greater specific gravity, which results in a more rapid phase-separation on shaking with the aqueous solution. Carbon tetrachloride is less soluble in water (0.08%) than is chloroform (0.8%), and is also less toxic. Solutions of about 0.01% (10 mg/100 ml) concentration can be stored for a long time if kept cool and in the dark. In spectrophotometric determinations use is mostly made of 0.001-0.002% solutions in CC14 or CHC13. The dilute solutions must not be stored. The stability of dithizone solutions and of metal dithizonates depends on the purity of the solvents used [88]. It is very important that the carbon tetrachloride and chloroform contain no oxidizing substances (e.g., chlorine from their decomposition). The procedure for purifying and recovering CC14 and CHC13 is given in Section 46.2.1. In the presence of surfactants it is possible to determine metals with dithizone directly in the aqueous phase, with no extraction [93]. Di-(2-naphthyl)thioearbazone (dinaphthizone), an analogue of dithizone, is also applied to the spectrophotometric determination of certain metals. The reagent solution in CC14 or CHC13 is blue. The solubility of metal dinaphthizonates in organic solvents is lower than that of dithizonates. Reagents related to dithizone are: 1,5-diphenylcarbazide (formula 17.1), a reagent for Cr(VI) and Os, and diphenylcarbazone which is used, inter alia, for determining mercury. To the same family of reagents belong 1,5-diphenylthiosemicarbazide (formula 42.1) and 2,4-diphenylthiosemicarbazide, which are valuable spectrophotometric reagents for Ru, Re, Se, and Te. The application of thiosemicarbazones and semicarbazones in spectrophotometry has been reviewed [94,95].
4.6. Dithiocarbamates Sodium diethyldithiocarbamate (Na-DDTC, formula 4.40) is the dithiocarbamate most commonly used in spectrophotometric analysis [96-98].
C2H5
~N___C//
CzH/
CzHs_
/~S
~S-Na '+
(4.40)
CzH/
S ยง
(4.41
4.7. 8-Hydroxyquinoline
67
The metal diethyldithiocarbamates are sparingly soluble in water, but dissolve in organic solvents such as CHC13, CC14,amyl acetate, or acetone. Spectrophotometric methods using Na-DDTC are rather insensitive since the colours of metal complexes with DDTC are not intense. Complexes with Cu, Bi, and Mn are among the most intensely coloured diethyl dithiocarbamates. The yellowish Ag-DDTC is used in the determination of arsenic (reaction with ASH3, see Section 8.2.2). Fig. 19.1 shows the absorption spectra of some metal diethyldithiocarbamates. In the reactions with metal ions, chelates with the uncommon four-membered ring are formed. Carbon tetrachloride extracts the complexes of Bi, Fe, Cu, Ni, Co, Pb; Te; As, Se; and Mn over the pH ranges 4-11; 4-9; 4-6; and 6-9, respectively. Complexes of many metals can be extracted into chloroform from fairly strongly acid solutions, e.g., from 0.1 M HC1. The diethyldithiocarbamates of Nb, Ru, Rh, Os, Ir and Pt are rather poorly extractable [99,100]. Sodium diethyldithiocarbamate decomposes in acid solution, forming diethylamine and carbon disulphide: (CzHs)zN.CS.SNa + H + ~ (CzH5)zNH + C82 -k-Na + Hence Na-DDTC solutions are stored in dilute alkali ( p H - 9).
Diethylammonium diethyldithiocarbamate (formula 4.41), which dissolves in CHC13 and is stable in acid solution, is a more convenient reagent than Na-DDTC. In this case the reagent is not added to the aqueous medium, but the analysed solution is shaken with a dilute (e.g., 0.05%) solution of the reagent in CHC13. The acidity of the solutions being analysed may be higher than in the case of Na-DDTC [101,102]. The stability of diethyldithiocarbamate complexes with metals decreases in the following order: Hg, Ag, Co, Cu, Ni, Bi, Pb, Cd, Fe(III), Zn, Mn By taking advantage of the different stabilities of individual metal dithiocarbamates, it is possible to use chloroform solutions of the relatively less-stable metal dithiocarbamates for the extraction of the metals which give more stable complexes [ 103-105]. In determining copper, for example, the colourless chloroform solution of lead diethyldithiocarbamate, Pb(DDTC)2, is used as the reagent. In this way the selectivity of metal reactions with dithiocarbamates may be enhanced. Other dithiocarbamates which have been applied as spectrophotometric reagents are: dibenzyl dithiocarbamate, pyrazoline dithiocarbamate, glycine dithiocarbamate, and pyrrolidine dithiocarbamate [ 106].
4.7. 8-Hydroxyquinoline 8-Hydroxyquinoline (HOx, oxine, formula 4.42) is amphoteric. It dissolves in alkaline solutions as the oxinate ion and in acid solutions as the oxinium cation. Oxine is soluble in CHC13, C6H6, CC14, ethanol, acetone, and other organic solvents [107,108]. The distribution of oxine between CHC13 and water depends on pH (Fig. 4.5).
68
4. Spectrophotometric reagents
BI"
!
OH
(4.42)
SH
(4.43)
(4.44)
With certain metal ions oxine forms chelates, which are in most cases extractable into CHC13 and other solvents. Metals form complexes with oxine in an M:Ox ratio, which depends on the charge on the metal ion. ~'00
|,
3
5
7
-
i
pH
9
11
Fig. 4.5. Distribution of 8-hydroxyquinoline between chloroform and water in relation to pH
In chloroform solution, 8-hydroxyquinoline has an absorption maximum at 315 nm. Solutions of all the metal oxinates are coloured, yellow predominating. Extractive spectrophotometric methods for the determination of metals with oxine are moderately sensitive (cf, the determination of A1, Ce, and V). The molar absorptivities of oxinates do not in general exceed 1-104. 8-Hydroxyquinoline is a group reagent often applied to the precipitation or extraction of a large number of metals. The selectivity of metal reactions with oxine may be enhanced by masking agents such as EDTA, tartrate, oxalate, or cyanide. In acid medium, and with some metal ions [e.g., Fe(III), Mo(V), Cr(IH)] oxine forms coloured water-soluble cationic complexes which can be used for the spectrophotometric determination of these metals. Oxygen-containing organic solvents extract the charged forms of the reagent as ionpairs. Some metals (Ni, Zn, U) form anionic oxine complexes, which form with basic dyes ion-associates, extractable into benzene [109]. Derivatives of 8-hydroxyquinoline are also used in spectrophotometric analysis. Chloro-oxine (5,7-dichloro-8-hydroxyquinoline) and bromo-oxine (5,7-dibromo-8hydroxyquinoline, formula 4.43) react similarly to oxine. The absorption maxima of the complexes in chloroform solutions are shifted towards longer wavelengths and the sensitivity of the reactions is higher than in the case of oxine. 8-Hydroxyquinoline derivatives containing sulphonic acid groups, e.g., ferron [a reagent for iron(IN), give water-soluble complexes with metal ions. 8-Mereaptoquinoline (thio-oxine, formula 4.44), the sulphur analogue of 8hydroxyquinoline, forms sparingly soluble chelates with metal ions (Fe, Cu, Mn, Cd, Co,
4.8. Other organic reagents
69
Mo, W, and Ni) [110,111]. Thio-oxine compounds are coloured and extractable into chloroform. The molar absorptivities range from 5-103 to 1-104. 8-Mercaptoquinolates are extracted from more acidic solutions than are oxinates, but are susceptible to oxidation.
4.8. Other organic reagents Hydroxylamine derivatives are used in determination of certain metals [112,113]. For example, the substitution of a benzoyl group (C6H5CO) for one of hydrogen atoms in hydroxylamine gives benzohydroxamic acid. Other important reagents in this group are Nbenzoyl-N-phenylhydroxylamine (BPHA), also called N-phenylbenzohydroxamic acid [114,115] and N-furoylphenylhydroxylamine. All these reagents form extractable chelates and are used for determination of metals, e.g., V(V), Mn, Ti, Fe(III), and Nb. Hydrazones are characterized by the presence of the triatomic grouping =C=N-N=. There are many reagents in this class, and they are used for spectrophotometric determination of such metals as Ni, Co, Zn, Cd, Cu [116-119]. Examples of these reagents are pyridine-2-aldehyde-2-quinolylhydrazone (PAQH) and cuprizone (formula 19.5). Dioximes are a group of reagents used in determination of Ni, Pd, Re, and Cu. The group is represented by dimethylglyoxime (formula 32.1) and ~-furyldioxime (formula 32.2). Their analytical applications have been reviewed [120,121]. Formaldoxime is a simple reagent [122] highly selective for manganese (see Section 29.2.2). 13-Diketones are a group of commonly applied spectrophotometric reagents, including acetylacetone (formula 1.6), thienoyltrifluoroacetone (formula 1.7), and dibenzoylmethane (formula 54.1) used as a reagent for uranium. The reagents of this group are discussed in a monograph [123]. Fluorinated ~-diketones are applied in the determination of lanthanides [124]. Thio-Miehler's ketone (formula 46.2) is a very useful reagent allowing sensitive and selective spectrophotometric determination of a limited group of metals (Ag, Au, Pd, Pt, Hg, Cu) [125,126]. Ref. 124 is not cited in the MS. Formula 4.41 is not shown in the MS. Maeroeyeles (crown ethers, cryptands) with chromogenic groups combine the natural selectivity of macrocycles with the possibility of direct spectrophotometric determination of some metals (e.g., K, Ca) in an organic phase after extraction [127-129]. 4Picrylaminobenzo-15-crown-5 crown ether (formula 4.41) is applied in the extraction and spectrophotometric determination of potassium. The determinations are based on extractable ion-associates of metals (e.g., Li, Na, K, Pb) with crown ethers and xanthene or sulphophthalein dyes [ 130].
rโข02
r,~o._..~ (4.45)
70
4. Spectrophotometricreagents
4.9. Inorganic reagents 4.9.1. Thiocyanate Thiocyanate is one of the most important spectrophotometric reagents. The availability of the reagent and the simplicity of thiocyanate methods are responsible for its great popularity in analytical laboratories [131,132]. Thiocyanate is principally used for determination of Fe(III), Mo, W, Nb, Re, Co, U, and Ti. The determination of metals by thiocyanate is carried out in aqueous or aqueous-acetone media, or after extraction with oxygen-containing solvents. The extractability of metal complexes depends on the acidity of the medium, the concentration of thiocyanate, and the organic solvent. The more acidic is the aqueous phase, and the higher the thiocyanate concentration, the more thiocyanic acid (HSCN) is also extracted by the organic phase. Stepwise formation of thiocyanate complexes gives cationic (e.g., FeSCN2+), neutral [e.g., Fe(SCN)3], and anionic [e.g., Fe(SCN)4-] species. The last is formed at high thiocyanate concentrations. With organic bases such as pyridine, tributylamine, and diantipyrylmethane, anionic thiocyanate complexes form ion-pairs which can be extracted into chloroform and other inert solvents. Increased selectivity in the determination of metals by thiocyanate is obtained by the choice of acidity, thiocyanate concentration, masking agent, and metal oxidation state. For example, the presence of a reducing agent is necessary for colour reactions with Mo, W, and Re. The reducing medium precludes the colour reaction of thiocyanate with iron. Thiocyanate methods vary widely in sensitivity. The methods for determining Te, Fe(III), and Nb are highly sensitive, whereas those for U and Co are less sensitive. The colour stability of some thiocyanate systems is low (e.g., that with iron). This is connected with either the reducing properties of the thiocyanate or the slow polymerization of thiocyanic acid in acid solutions, which causes yellowing. Solvents miscible with water increase the colour intensity of thiocyanate complexes in aqueous solutions. This is apparently owing to the lowered dielectric constants of the media, which inhibit dissociation of the complexes. Anionic thiocyanate complexes are extractable as ion-association species with basic dyes (see Section 4.4.1).
4.9.2. Other inorganic reagents In the spectrophotometric determination of Si, Ge, P(V), As(V), and V(V) the yellow heteropoly adds occurring in acid solutions in the presence of an excess of molybdate or tungstate are important. The yellow heteropoly acids are the basis of less sensitive spectrophotometric methods, but the blue reduction products (e.g., phosphomolybdenum blue) are the basis of very sensitive spectrophotometric methods for determining these elements. The conditions for formation and extraction of these compounds have been investigated [ 133-135]. Other inorganic reagents utilized in spectrophotometric methods are: hydrogen peroxide (see determination of Ti, V, U, and Ce), SnCI3 ion (determination of platinum group elements [136]), iodide (see determination of Sb, Bi, and Pd), bromide (determination of Au), and also chloride and azide.
4. Spectrophotometricreagents
71
References 1. Sandell E.B., Onishi H., Photometric Determination of Traces of Metals. General Aspects (Chapters 5 and 6), Wiley, New York 1978. 2. Cheng K.L., Ueno K., Imamura T., Handbook of Organic Analytical Reagents, CRS Press, Boca Raton 1982. 3. Sommer L., Ackermann G., Burns D.T., Savvin S.B., Pure Appl. Chem., 62, 2147, 2323 (1990). 4. Townshend A., Burns D.T., Guibault G.G., Lobif~ski R., Marczenko Z., Newman E.J., Onishi H., Dictionary of Analytical Reagents, Chapman and Hall, London 1993. 5. Salikhov V.D., Tyutyunnikova L.D., Zh. Anal. Khim., 30, 1469 (1975). 6. Salikhov V.D., Zh. Anal. Khim., 36, 16, 30 (1981). 7. Stephen W.I.,Analyst, 102, 793 (1977). 8. Sommer L., Ackermann G., Burns D.T., Pure Appl. Chem., 62, 2323 (1990). 9. Navaz-Diaz A., Talanta, 38, 571 (1991). 10. Anderson R.G., Nickless G., Analyst, 92, 207 (1967). 11. Pilipenko A.T., Savransky L.I., Talanta, 25, 451 (1978). 12. Betteridge D., Fernando Q., Freiser H., Anal. Chem., 35, 294 (1963). 13. Betteridge D., Todd P.K., Fernando Q., Freiser H., Anal. Chem., 35, 729 (1963). 14. Pfischel R., Z. Anal. Chem., 221, 132 (1966). 15. Geary W.J., Nickless G., Pollard F.H.,Anal. Chim. Acta, 26, 575; 27, 71 (1962). 16. Wuench G., Doepke T., Fresenius'Z. Anal. Chem., 335, 876 (1989). 17. Mamuliya S.G. et al., Zh. Anal. Khim., 35, 1307 (1980). 18. Shibata S., Furukawa M., T6ei K.,Anal. Chim. Acta, 66, 397 (1973). 19. Johnson D.A., Florence T.M., Talanta, 22, 253 (1975). 20. MiuraJ.,Analyst, 114, 1323 (1989). 21. Katami T. et al., Anal. Sci., 2, 169 (1986). 22. Navratil O., Coll. Czech. Chem. Comm., 29, 2490 (1964). 23. Stanley R.W., Cheney G.E., Talanta, 13, 1619 (1966). 24. Nickless G., Pollard F.H., Samuelson T.J., Anal. Chim. Acta, 39, 37 (1967). 25. Hovind H.R., Analyst, 100, 769 (1975). 26. Savvin S.B., Talanta, 8, 673 (1961); 11, 1,7 (1964). 27. Savvin S.B., Organic Reagents of Arsenazo III Group, Atomizdat, Moscow, 1971. 28. Dedkova V.P., Akimova T.G., Savvin S.B., Zh. Anal. Khim., 38, 1383 (1983). 29. Luk'yanov V.F., Novak E.F., Zh. Anal. Khim., 40, 145 (1985). 30. N~mcova J., Metal B., Podlaha J., Talanta, 33, 841 (1986). 31. Dedkova V.P., Savvin S.B. et al., Zh. Anal. Khim., 51,730 (1996). 32. Savvin S.B. et al., Zh. Anal. Khim., 44, 1809 (1989). 33. Ivanov V.M., Zh. Anal. Khim., 46, 645 (1991). 34. Savvin S.B., Petrova T.V., Dzherayan T.G., Zh. Anal. Khim., 35, 1485 (1980). 35. Calvo M., Marina M.L., Rodriguez A.R., Gonzalez V., Microchem. J., 34, 289 (1986). 36. Woodward C., Freiser H., Talanta, 20, 417 (1973). 37. Petrova T.V., Savvin S.B. et al., Zh. Anal. Khim., 50, 1823 (1985). 38. Ivanov V.M., Rudometkina T.F., Zh. Anal. Khim., 33, 2426 (1978). 39. Savos'kina L.N., Nemodruk A.A., Oskotskaya E.P., Zh. Anal. Khim., 36, 1483 (1981). 40. Pringle D.L. et al., Talanta, 29, 1097 (1982). 41. Pollakova-Moukova N., Gotzmannova D., Kubafi V., Coll. Czech. Chem. Comm., 46, 354(1981). 42. Ivanov V.M., Collazo J., Castro M.T., Zh. Anal. Khim., 43, 606 (1988).
72
43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. 69. 70.
4. Spectrophotometricreagents
Martynov A.P., Novak V.P., Reznik B.E., Zh. Anal. Khim., 32, 519 (1977). Pantaler R.P., Pulyaeva I.V., Zh. Anal. Khim., 35, 1021 (1980). Tikhonov V.N., Fedotova N.S., Zh. Anal. Khim., 37, 1889 (1982). Tikhonov V.N., Anisimova T.M., Zh. Anal. Khim., 38, 778 (1983). Tikhonov V.N., Zh. Anal. Khim., 39, 1796 (1984). Murakami S., Yoshino T., Talanta, 28, 623 (1981). Tikhonov V.N., Zh. Anal. Khim., 41, 1353 (1986). Yoshino T., Imada H., Kuwano T., Iwasa K., Talanta, 16, 151 (1969). Nakada S., Yamada M., Ito T., Fujimoto M., Bull. Chem. Soc. Jpn., 53, 3365 (1980). Michaylova V., Sucha L., Suchafiek M., Talanta, 31,645 (1984). Nakayama H., Tachiyashiki S., Shimizu E.,Anal. Sci., 4, 595 (1988). Bure~ova I., Kubafi V., Sommer L., Coll. Czech. Chem. Comm., 46, 1090 (1981). Savvin S.B., Chernova R.K. et al., Zh. Anal. Khim., 36, 1461 (1981). Callahan J.H., Cook K.D., Anal. Chem., 56, 1632 (1984). Pelizzetti E., Pramauro E.,Anal. Chim. Acta, 169, 1 (1985). Diaz Garcia M.E., Sanz-Medel A., Talanta, 33, 255 (1986). Perov R.A. et al., Zh. Anal. Khim., 42, 1582 (1987). Jarosz M.,Analyst, 112, 1279 (1987). Jarosz M., Marczenko Z., Chem. Anal. (Warsaw), 37, 63 (1992). Antonovich V.P. et al., Zh. Anal. Khim., 32, 876 (1977). Antonovich V.P. et al., Zh. Anal. Khim., 31, 2302 (1976). Wyganowski C., Microchem. J., 29, 318 (1984). Savvin S.B. et al., Zh. Anal. Khim., 36, 1471 (1981). Nazarenko V.A. et al., Zh. Anal. Khim., 29, 1478 (1974). Al'bota L.A., Zh. Anal. Khim., 41, 1780 (1986). Zadorozhnaya E.M., Nabivanets B.I., Masley N.N., Zh. Anal. Khim., 29, 993 (1974). Marczenko Z., Mikrochim. Acta, 1977 II, 651. Lomonosov S.A., Zh. Anal. Khim., 28, 1653, 1669, 1877, 2085, 2091 (1973); 29, 1261 (1974). 71. Poluektov N.S., Drobyazko V.N., Meshkova S.B., Zh. Anal. Khim., 28, 1408 (1973). 72. Rochat J., Rerat J.C., Alary J., Coeur A., Analusis, 4, 267 (1976). 73. Blum I.A., Brushtejn N.A., Zh. Anal. Khim., 31, 1669 (1976). 74. Zorov N.B. et al., Zh. Anal. Khim., 26, 1466 (1971). 75. Dodin E.I., Kharlamov I.P., Zh. Anal. Khim., 37, 14 (1982). 76. Chelnokova M.N., Zh. Anal. Khim., 37, 1008 (1982). 77. Zhivopistsev V.P., Zh. Anal. Khim., 50, 714 (1995). 78. Kish P.P., Pogoyda I.I., Zh. Anal. Khim., 34, 1687 (1979). 79. Matveets M.A., Shcherbov D.P., Akhmetova S.D., Zh. Anal. Khim., 34, 1049 (1979). 80. Fompeydie D., Levillain P., Talanta, 31, 1125 (1984). 81. Skorobogatov V.M., Gershuns A.L., Adamovich L.P., Zh. Anal. Khim., 32, 1450 (1977). 82. Tananayko M.M., Gorenshtein L.I., Zh. Anal. Khim., 37, 589 (1982). 83. Iwantscheff G., Das Dithizon und seine Auwendung in der Mikro- und Spurenanalyse, 2nd Ed., Verlag Chemie, Weinheim 1972. 84. Irving N.M., Dithizone, Royal Society of Chemistry, London 1977. 85. Irving N.M., Crit. Rev. Anal. Chem., 8, 321 (1980). 86. Wagler H., Koch H., Talanta, 31, 1101 (1984). 87. Freiser B.S., Freiser H., Anal. Chem., 42, 305 (1970). 88. Brand P., Freiser H., Anal. Chem., 46, 1147 (1974).
References
89. Laing M., Alsop P.A., Talanta, 17, 242 (1970). 90. Marczenko Z., Mojski M., Chem. Anal. (Warsaw), 54, 29 (1972). 91. Vinokurova O.B., Kletenik Yu.B., Zh. Anal. Khim., 31, 1067 (1976). 92. Dodin E.I., Grigor'eva L.A., Kharlamov I.P., Zh. Anal. Khim., 32, 1095 (1977). 93. Paradkar R.P., Williams R.R.,Anal. Chem., 66, 2752 (1994). 94. Singh R.B., Garg B.S., Singh R.P., Talanta, 25, 619 (1978). 95. Garg B.S., Jain V.K., Microchem. J., 38, 144 (1988). 96. Hulanicki A., Talanta, 14, 1371 (1967). 97. Halls D.J., Mikrochim. Acta, 1969, 62. 98. Bajo S., Anal. Chim. Acta, 105, 281 (1979). 99. Babko A.K. et al., Zh. Anal. Khim., 22, 670 (1967). 100. Usatenko Yu.I., Barkalov V.S., Tulyupa F.M., Zh. Anal. Khim., 25, 1458 (1970). 101. Honjo T., Imura H., Bull. Chem. Soc. Jpn., 53, 1753 (1980). 102. Nazarenko V.A. et al., Ukr. Khim. Zh., 53, 722 (1987). 103. Wyttenbach A., Bajo S.,Anal. Chem., 47, 1813 (1975). 104. Bajo S., Wyttenbach A.,Anal. Chem., 51, 376 (1979). 105. Wasey A., Bansal R.K., Satake M., Purl B.K., Bull. Chem. Soc. Jpn., 57, 980 (1984). 106. Likussar W., Boltz D.F.,Anal. Chem., 43, 1273 (1971). 107. Mottola H.A., Freiser H., Talanta, 14, 864 (1967). 108. Yuchi A. et al., Bull. Chem. Soc. Jpn., 60, 4291 (1987). 109. Zolotov Yu.A. et al., Zh. Anal. Khim., 25, 1845 (1970). 110. Corsini A., Fernando Q., Freiser H.,Anal. Chem., 35, 1424 (1963). 111. Veveris O.E. et al., J. Radioanal. Chem., 9, 47 (1971). 112. Shendrikar A.D., Talanta, 16, 51 (1969). 113. Buscarons F., Canela J., Anal. Chim. Acta, 67, 349 (1973). 114. Shpak E.A., Satsyuk V.A., Pilipenko A.T., Zh. Anal. Khim., 33, 642 (1978). 115. Shpak E.A., Satsyuk V.A., Zh. Anal. Khim., 34, 1849 (1979). 116. Katyal M., Dutt Y., Talanta, 22, 151 (1975). 117. Asuero A.G., Microchem. J., 24, 217 (1979). 118. Singh R.B., Jain P., Singh R.P., Talanta, 29, 77 (1982). 119. Odashima T., Ishii H.,Anal. Chim. Acta, 277, 79 (1993). 120. Egneus B., Talanta, 19, 1387 (1972). 121. Singh R.B., Garg B.S., Singh R.P., Talanta, 26, 425 (1979). 122. Marczenko Z., Bull. Soc. Chim. France, 1964, 939; Anal. Chim. Acta, 31,226 (1964). 123. Peshkova V.M., Melchanova N.V., fl-Diketony, Nauka, Moscow 1986. 124. Topilova Z.M. et al., Zh. Neorg. Khim.,, 34, 2224 (1989). 125. Cheng K.L., Goydish B.L., Microchem. J., 10, 158 (1966). 126. Pilipenko A.T., Ryabushko O.P., Matsibura G.S., Zavod. Lab., 48, No 5, 7 (1982). 127. KolthoffI.M.,Anal. Chem., 51, 1R (1979). 128. Krasnushkina E.A., Zolotov Yu.A., Trends Anal. Chem., 2, 158 (1983). 129. Katayama Y. et al.,Anal. Chim. Acta, 173, 193 (1985). 130. Mchedlov Petrosyan N.O. et al., Zh. Anal. Khim., 49, 177 (1994). 131. R62ycki C., Chem. Anal. (Warsaw), 11,447 (1966); 14, 755 (1969); 15, 3 (1970). 132. Jurriaame A., Kemp D.M., Talanta, 15, 1287 (1968). 133. Wtinsch G., Umland F., Z. Anal. Chem., 250, 248 (1970). 134. Alt F., Umland F., Z Anal. Chem., 274, 103 (1975). 135. Dorokhova E.H., Alimarin I.P., Uspekhi Khim., 48, 930 (1979). 136. Balcerzak M., Analusis, 22, 353 (1994).
73
This Page Intentionally Left Blank
Part II
Determination of elements
Introductory remarks Part II, devoted to individual chemical elements, describes the methods for separation, preconcentration, and spectrophotometric determination of the elements, as well as the application of these methods in the analysis of materials. The detailed discussion comprises the theory, preparation of standard solutions, and analytical procedures. The analytical procedures are presented in a unified form. The maximum quantities given for a corresponding analyte refer to a 25 ml standard flask and a cuvette of thickness 1 cm. The quantities of reagents should be changed if the coloured solutions are placed in a flask of capacity 10 ml or 50 ml, and a cuvette of other thickness is applied. In the descriptions of preparations of reagents and in analytical procedures no mention is given of the purity of reagents. The assumption is made that the analyst will use reagents of purity appropriate for the given analysis. Procedures are given for the preparation of stock standard solutions of elements of concentration 1 mg/ml. If no other statement is given, the working solutions (of concentration 100, 10, or 1 ~tg/ml) are prepared by appropriate dilution of the stock solutions. Series of solutions for obtaining standard curves are prepared conforming to the analytical procedure, but suitable volumes of the working standard solutions are used instead of the sample solution. The sensitivity of the spectrophotometric methods is determined in terms of the molar absorption coefficient (molar absorptivity, coefficient e), e.g., e = 4.86104 1 mole -1 cm -~ and specific absorptivity (a = e/m.mole'1000 [ml'~tg-l"cm-~]. For space-saving reasons the units of ~ and a have been omitted from the text. The formulae of organic reagents have been given in their acid- or ionic forms, although they are supplied commercially as salts. The letter M stands in the book for "mole/l" or "molar".
Chapter 5. Alkali metals Lithium (Li, at. mass 6.94), sodium (Na, at. mass 22.99), potassium (K, at. mass 39.10), rubidium (Rb, at. mass 85.47), and caesium (Cs, at. mass 132.91) form colourless M + ions, readily soluble in water, and strong bases MOH. Potassium, rubidium, and caesium are very similar in chemical properties. Sodium has somewhat different properties. The properties of lithium are intermediate between those of sodium and calcium. Lithium and sodium have the ability to form weak complexes (e.g., with pyrophosphate and EDTA).
5.1. Isolation and separation of the alkali metals Owing to the good water-solubility of the alkali metal salts, the simplest way to isolate them from the Analytical Group I-IV metals is by leaching a carefully powdered sample with very dilute acid (e.g., HC1) or dilute alkali (e.g., ammonia), depending on the nature of the sample under examination. Multivalent metals can be separated from the alkali metals by solvent extraction or precipitation methods. Cation exchangers and electrolysis with a mercury cathode are useful in separating the metals of other groups from the alkali metals. The alkali metals can be separated by cation-exchange chromatography using strongly acidic cation-exchangers [ 1-7]. The isolation of small amounts of lithium, and of caesium and rubidium, is described in references [8] and [9,10], respectively. The separation of Na, K, Ca, and Mg was also investigated [11 ]. In the separation of caesium, the following inorganic cation exchangers are particularly useful: potassium cobalt(H) hexacyanoferrate(II) [12,13], potassium copper(II) and nickel(II) hexacyanoferrates(II) [ 14], ammonium molybdophosphate [ 13,15], zirconium molybdoarsenate [16], thallium tungstophosphate [17], and tin molybdosilicate [18]. Rubidium has been selectively isolated on columns filled with titanium tungstoarsenate [ 19] or titanium ferricyanide [20]. Ammonium molybdoarsenate has been used to separate potassium from sodium [21 ]. Maeroeyelie compounds (some crown ethers and cryptands) are selective reagents for extractive separation of alkali metals [22-27]. These ligands form cationic complexes with alkali metal ions, and these can be extracted as ion-pairs with suitable counter-ions (e.g., picrate) [28], most often into chloroform. For potassium, p-nitrophenoxide was used as counter-ion [29]. In cases, where a coloured anionic complex is a counter-ion [30], the extract may serve as a basis for determining the alkali metal. The effect of the structure of the dibenzo-crown ether rings upon the selectivity and effectiveness of isolation of alkali metals has been studied in detail [31]. Chromogenic macrocyclic reagents applied for the isolation and separation of alkali metals have been discussed [32]. The effect of the presence of crown ethers in the eluents [7,33], or in the stationary phases [34-37] on the effectiveness of separation of alkali metals on cation exchangers has been investigated. Higher selectivity of Na separation was observed on silica resins impregnated with calixarene [38]. The alkali-metal tetraphenylborates have been separated by virtue of their different distribution coefficients when extracted with nitrobenzene [39]. The extraction of alkali
78
5. Alkali metals
metals with pyrazolone derivatives has been studied [40-42]. Lithium can be separated from sodium by extraction with a cyclohexane solution of 1-tolyl-3-methyl-4-perfluoroacyl-5pyrazolone and TOPO [40]. Rubidium and caesium have been separated with the use of 4butyl-2-(a-methylbenzyl)phenol and mixture of n-octane with CC14 [43]. Dioxan leaches only lithium chloride from a mixture of dried alkali metal chlorides [44].
5.2. Determination of lithium Lithium is the only alkali metal, which gives colour reactions with some azo dyes. The first reagent used in the direct determination of lithium was Thoron I (formula 4.9) [45,46]. The reaction is performed in aqueous or acetone-water media (e-~ 6.103 at 486 nm). A fifty-fold amount of sodium and a tenfold amount of magnesium do not interfere. The solutions are made alkaline with KOH. Nitroanthranylazo (formula 5.1) has been proposed for the determination of Li [47]. The colour reaction is carried out in aqueous acetone made alkaline with KOH. The absorbance is measured at 530 nm ( e - 1.2.104). The colour intensity depends on the medium used (water-acetone, dioxan, methanol, DMF), excess of Nitroanthranylazo, and ionic strength. In the determination of 2 pg of lithium, there is no interference of 200 pg Rb, 100 pg Mg or Ca, 50 pg Ba, Sr, or Na, The method has been applied for determination of lithium in ferrites [48].
O2N,~,,~~COOH
OH b
(5.1)
CH3
Formazan reagents are highly selective to lithium. The use of formazan enables the determination of Li in the presence of a 5,000-fold excess of Na, which is of importance in the determination of Li in blood [49,50]. Lithium was determined also with another reagent from this group, (e = 2.0-104) [51]. Quinizarine was used for determination of Li in drugs and in blood serum [52]. Macrocyclic reagents, such as chromogenic crown ethers of the type 14-crown-4 (extraction to 1,2-dichloroethane in the presence of picrate) were used for determination of Li [53]. The 14-crown-4 type derivatives have been applied for determination of Li in blood by a continuous FIA method [54,55]. The use of chromogenic reagents aza-12 (-13 or -14)crown-4 has also been proposed [56,57]. The effect of substituents on the selectivity of separation of Li (and Na) by means of benzo-14-crown-4 and 13-crown-4 ethers was studied [58]. A review of chromogenic macrocyclic reagents used for determination of lithium (and other alkali metals) has been published [32].
5.3. Determination of sodium Sodium is separated from other alkali metals by precipitation from acetic acid medium as the triple acetate, NaZn(UOz)3(CH3COO)9-9H20 [59]. When the potassium content exceeds the sodium content by greater than one hundred-fold, it is partly co-precipitated with the sodium. In this case, double precipitation is advisable. The precipitated triple acetate is then
5.4. Determination of potassium
79
dissolved, and sodium is determined indirectly by the spectrophotometric determination of zinc with dithizone. Sodium can be determined directly by selective methods involving chromogenic macrocyclic reagents, e.g., crown ethers of the type 15-crown-5 (e= 1.4-104 at 422 nm) [60], of the type 12-crown-4 (with picrate counter-ion, in 1,2-dichloroethane, e = 1.8.104 at 375 nm) [61], 18-crown-6 [62,63], crown ether with azo group [64], cryptand-(2,1,1) (picrate, toluene, 350-fold excess of K does not interfere) [65], and (2.2.2)-cryptand [63]. The crown ether, benzo-18-crown-6, has been applied in the FIA technique [62]. These reagents have been used for the determination of Na in blood. The co-extraction of Cs and Na was studied with the use of various crown ethers [66]. A review of the reagents has been published [32]. Sodium has been extracted (CHC13) in the form of mixed complexes with 15-crown-5 ether or with Bromothymol Blue [67]. The FIA procedure was applied for the determination of Na (and K) with the use of 18-crown-6 and tetrabromophenolphthalein [68].
5.4. Determination of potassium Analytical methods based on the use of crown-ethers are highly selective. It is possible to use either chromogenic crown-ethers [32,69-72] (e.g., formula 5.2), or crown-ethers without chromogenic groups [62,73-77], e.g., dibenzo-18-crown-6 (formula 1.15) in conjunction with anionic chromophoric reagents as counter-ions, e.g., Bromocresol Green [73], or Methyl Orange [74]. Potassium was determined also as an ion-pair of a complex of 18crown-6 ether with Bromothymol Blue [78] or calmagite [79]. Methods involving the potassium complex with [2.2.2]-cryptand associated with Methyl Orange (CHC13, = 2.2104) [80] or with a complex of Co(III) with an azo compound [81] have been proposed. H
N..~--N
0/--"~0 (5.2)
The above-mentioned methods were applied for the determination of potassium in blood serum [72,73,82], biological fluids [79], water [75,76], and cement [76]. The FIA technique was also applied [76]. Dilituric acid (5-nitrobarbituric acid) forms a sparingly soluble compound with potassium ions. The decrease in absorbance of the reagent gives a measure of the K content in the solution. Potassium ions can be precipitated by tetraphenylborate. The excess reagent forms an ion-pair with the cationic Cu(I)-neocuproine complex, and this ion-pair is extractable into methyl acetate. The absorbance of the extract is measured at 456 nm [83]. An indirect method involving the reaction of potassium tetraphenylborate with mercury(II) chloranilate is very sensitive [84]. Potassium was determined by the FIA method after precipitation with tetraphenylborate and the crown ether, 18-crown-6 [85].
80
5.Alkali metals
5.5. Determination of rubidium and caesium Rubidium and caesium are determined, like potassium, by indirect spectrophotometric methods, with the use of dipicrylamine [86] or picric acid [87]. Caesium is separated from small amounts of rubidium and potassium as the sparingly soluble caesium tungstosilicate. The precipitate is dissolved, the tungstosilicic acid is reduced to silicotungsten blue, and the absorbance is measured at 640 nm [88]. Caesium has been also determined indirectly as phosphomolybdenum blue (absorbance measured at 805 nm) after the precipitation of, and isolation of caesium molybdophosphate [89]. Caesium was also determined indirectly by precipitation of Cs3BizI9 with subsequent determination of Bi by the iodide method [90]. Some crown ethers [70,91,92] are used for the extraction and spectrophotometric determination of Rb and Cs.
References 1. Strelow F.W., Coetzee J.H., Van Zyl C.R., Anal. Chem., 40, 196 (1968). 2. Strelow F.W., Liebenberg C.J., Toerien S.,Anal. Chim. Acta, 43, 465 (1968). 3. Huber J.F., Van Urk-Schoen A.M., Anal. Chim. Acta, 58, 395 (1972). 4. Nair L.M., Saari-Nordhaus R., Anderson J.M. Jr., J. Chromatogr., 640, 41 (1993). 5. Narbutt J., Bilewicz A., Bartog B., Chem. Anal. (Warsaw), 33, 399 (1988). 6. Dumont P.J., Fritz J.S., J. Chromatogr. A, 706, 149 (1995). 7. Steiner F., Niederlaender C., Engelhardt H., Chromatographia, 43, 117 (1996). 8. Strelow F.W., Weinert C.H., Van der Walt T.N., Anal. Chim. Acta, 71, 123 (1974). 9. Hahn R.B., Johnson J.L., McKay J.B., Talanta, 13, 1613 (1966). 10. Shestakov G.I., Zh. Anal. Khim., 26, 273 (1971). 11. Iwachido T., Shinomiya M., Zenki M., Anal. Sci., 6, 277 (1990). 12. Boni A.L., Anal. Chem., 38, 89 (1966). 13. Terada K. et al., Talanta, 17, 955 (1970). 14. Ishfaq M.M., Karim H.M., Khan M.A., J. Radioanal. Nucl. Chem., 159, 335 (1992). 15. Oldham G., Ware A.R., Sykes D.J., Talanta, 16, 430 (1969). 16. Satyanarayana J. et al., J. Radioanal. Nucl. Chem., 188, 323 (1994). 17. Caron H.L., Sugihara T.T., Anal. Chem., 34, 1082 (1962). 18. Yassine T., J. Radioanal. Nucl. Chem., 173, 387 (1993). 19. Srivastava S.K. et al., Analyst, 109, 151 (1984). 20. Saraswat I.P. et al., Anal. Sci., 2, 343 (1986). 21. Coetzee C.J., Rohwer E.F., Anal. Chim. Acta, 44, 293 (1969). 22. Kimura K., Maeda T., Shono T., Talanta, 26, 945 (1979). 23. Strzelbicki J., Bartsch R.A., Anal. Chem., 53, 1894, 2251 (1981). 24. Mamedova Yu.G. et al., Zh. Anal. Khim., 38, 1578 (1983). 25. Yakshin V.V., Fedorova A.T., Laskorin B.N., Zh. Anal. Khim., 40, 45 (1985). 26. Sakamoto H. et al., Bull. Chem. Soc. Jpn., 69, 2907 (1993). 27. Tsurubou S., Umetani S., Komatsu Y., Anal. Chim. Acta, 394, 317 (1999). 28. Olsher U., Feinberg H., Frolow F., Shoham G., Pure Appl. Chem., 68, 1195 (1996). 29. Buncel E. et al., Talanta, 31,585 (1984). 30. Szczepaniak W., Juskowiak B., Chem. Anal. (Warsaw), 32, 787 (1987). 31. Walkowiak W. et al., Anal. Chem., 62, 2018, 2022 (1990).
References
32. Dolman M. et al., Analyst, 121, 1775 (1996). 33. Yoshida K., Motomizu S., J. Flow Injection Anal., 7, 130 (1990). 34. Hayashita T. et al., Anal. Chem., 62, 2283 (1990). 35. Hayashita T. et al.,Anal. Chem., 64, 815 (1992). 36. Okada T., Usui T., Anal. Chem., 66, 1654 (1994). 37. Edwards B.R., Giauque A.P., Lamb J.D., J. Chromatogr., 706, 69 (1995). 38. Glennon J.D. et al.,Anal. Lett., 26, 153 (1993). 39. Sekine T., Dyrssen D., Anal. Chim. Acta, 45, 433 (1969). 40. Umetani S. et al., Talanta, 34, 779 (1987). 41. Mukai H. et al., Anal. Chim. Acta, 220, 111 (1989). 42. Bukowsky H. et al., Anal. Chim. Acta, 257, 105 (1992). 43. Rais J., Krtil J., Chotivka V., Talanta, 18, 213 (1971). 44. Blasius E., Wolf F., Z. Anal. Chem., 174, 349 (1960). 45. Apple R.F., White J.C., Talanta, 13, 43 (1966). 46. Trautman J.K., Gadzekpo V.P., Christian G.D., Talanta, 30, 587 (1983). 47. Dziomko V.M. et al., Zh. Anal. Khim., 23, 170 (1968); 24, 985 (1969). 48. Budyak N.F., Gryaznova I.S., Zh. Prikl. Khim., 44, 669 (1971). 49. Sitnikova R.V. et al., Zh. Anal. Khim., 37, 611 (1982). 50. Attiyat A.S., Ibrahim Y.A., Christian G.D., Microchem. J., 37, 114 (1988). 51. Zelichenok S.L. et al., Zh. Anal. Khim., 30, 2311 (1975). 52. Gracia L.G., Rodriguez L.C., Ceba M.R., Talanta, 44, 75 (1997). 53. Wu Y.P., Pacey G.E.,Anal. Chim. Acta, 162, 285 (1984). 54. Kimura K. et al., Anal. Sci., 4, 221 (1988). 55. Kimura K. et al.,Analyst, 115, 1251 (1990). 56. Sasaki A., Pacey G.,Anal. Chim. Acta, 174, 141 (1985). 57. Wilcox K., Pacey G.E., Talanta, 38, 1315 (1991). 58. Bartsch R. et al., Anal. Chim. Acta, 272, 285 (1993). 59. Shell H.R., Anal. Chem., 22, 575 (1950). 60. Nakamura H. et al., Anal. Chim. Acta, 139, 219 (1982). 61. Pacey G.E., Wu Y.P., Talanta, 31, 165 (1984). 62. Motomizu S., Onoda M., Anal. Chim. Acta, 214, 289 (1988). 63. Kumar A. et al., Clin. Chem., 34, 1709 (1988). 64. Katayama Y., Nakamura H., Takagi M., Anal. Sci., 1, 393 (1985). 65. Takagi M. et al., Anal. Chim. Acta, 126, 185 (1981). 66. Peimli E., J. Radioanal. Nucl. Chem., 144, 1 (1990). 67. Lamoneda C., Barragan F.J., Guiraum A., Analusis, 16, 189 (1989). 68. Motomizu S., Onoda M., Anal. Chim. Acta, 214, 289 (1988). 69. Nakamura H., Takagi M., Ueno K., Talanta, 26, 921 (1979). 70. Nakamura H., Takagi M., Ueno K., Anal. Chem., 52, 1668 (1980). 71. Pacey G.E., Wu Y.P., Bubnis B.P., Analyst, 106, 636 (1981). 72. Bubnis B.P. et al., Anal. Chim. Acta, 139, 307 (1982). 73. Sumiyoshi H., Nakahara K., Ueno K., Talanta, 24, 763 (1977). 74. Abrodo P.A. et al., Microchem J., 30, 58 (1984). 75. Shabanov A.L. et al., Zh. Anal. Khim., 39, 1621 (1984). 76. Motomizu S. et al., Analyst, 113, 743 (1988). 77. Motomizu S., Kobayashi M., Anal. Sci., 10, 187 (1994). 78. Escobar R. et al.,Analyst, 114, 533 (1989). 79. Dadfarnia S., Shamsipur M., Anal. Lett., 25, 11 (1992).
81
82 80. 81. 82. 83. 84. 85. 86. 87. 88. 89. 90. 91. 92.
5. Alkali metals Abrodo P.A., Gomis D.B., Medel A.S., Microchem J., 32, 296 (1985). Yamada H., Kobayakawa I., Yuchi A., Wada H.,Anal. Chim. Acta, 281, 95 (1993). Kumar A. et al., Clin. Chem., 34, 1709 (1988). Khreish E.A., Boltz D.F., Mikrochim. Acta, 1970, 1174. Huber H. et al., Mikrochim. Acta, 1982 I, 155. Motomizu S., Yoshida K., T6ei K., Anal. Chim. Acta, 261, 225 (1992). Kyr~ M., Rais J., Selucky P., Talanta, 16, 1169 (1969). Hejtmanek H., Hozmanova E., Mikrochim. Acta, 1966, 97. Gorenc B., Kosta L., Z. Anal. Chem., 206, 321 (1964). Huey F., Hargis L.G., Anal. Chem., 39, 125 (1967). Boguslawska K., Cieplifiski M., Cygafiski A., Chem. Anal. (Warsaw), 30, 281 (1985). Mohite B.S., Khopkar S.M., Talanta, 32, 565 (1985). McDowell W.J. et al., Anal. Chem., 64, 3013 (1992).
Chapter 6. Aluminium Aluminium (A1, at. mass 26.98) occurs in solution exclusively in the HI oxidation state. The hydroxide AI(OH)3 begins to precipitate at about pH 4. Above pH 9 it is converted into the soluble tetrahydroaluminate anion. Aluminium forms stable complexes with fluoride, oxalate, tartrate, and EDTA, and weak complexes with acetate.
6.1. Methods of separation and preconcentration 6.1.1. Precipitation By precipitation of its hydroxide, with ammonia, or with an acetate buffer at pH 4.5-5.0, A1 can be separated from metals having hydroxides precipitated at higher pH values. Traces of aluminium are separated by using Ti, La, Zr, or Fe(III) as scavenger. It is possible to precipitate AI(OH)3 with ammonia at pH --5 in the presence of Fe masked by reduction to Fe(II). In order to separate aluminium from chromium, Cr(III) can be masked by oxidation to Cr(VI). The precipitation of AI(OH)3 in the presence of H202 enables one to separate A1 from Ti and V. Aluminium is separated as the soluble tetrahydroxo complex from Fe, Ti, and other metal ions which are insoluble in excess of NaOH [ 1]. The aluminium co-precipitated with the insoluble metal hydroxides should be recovered by dissolving the precipitate in dilute HC1, and then re-precipitating the interfering metals with excess of NaOH. Water leaches A1. (as aluminate) from a cooled melt of Na2CO3, while Fe, Ti, Zr, and other metals remain in the solid. Small amounts of aluminium may be precipitated as the oxinate, ff fluoride is present, it is masked as the stable, soluble beryllium complex [2]. Fe(III), Ti, and Zr are separated from aluminium by precipitation with cupferron [3]. Mercury-cathode electrolysis allows small quantities of A1 to be separated from large amounts of Fe, Ni, Co, Cu, Zn, Mn, Cr, Mo, Pb, etc., while Be, V, Ti, Zr, Mg, Ca, and the rare earths remain in solution together with the aluminium [4].
6.1.2. Extraction. Ion exchange Extraction is used mainly for the preliminary separation of macro- and microquantities of metals which interfere in the determination of aluminium. After Fe(III), Ti, Zr, and Cu cupferronates have been extracted from dilute HC1 into chloroform, aluminium cupferronate is extracted at pH --3.5 [5]. Some interfering metals are separated from A1 by extraction with trifluoroacetylacetone in CHC13 [6], and as chloride- or thiocyanate complexes in the presence of DAM [7]. Aluminium has been separated from various elements by extraction as chelates with BPHA [8], oxine [4,9], 8-hydroxyquinaldine [10], and acetylacetone [11]. Aluminium does not form a stable chloro-complex. It can be separated by passing a solution in 9 M HC1 through a strongly basic anion exchanger column. Aluminium is eluted along with Ni, Mn, Ca, Mg, Be, and Ti, whereas Fe, Cu, Zn, Co, Cd, etc., remain on the column [ 12].
84
6. Aluminium
Aluminium, gallium and indium can be retained on the anion exchanger from a solution of 2-methoxyethanol and 6 M HC1, and can then be sequentially eluted with 1 M HC1 [ 13]. Aluminium and other cations can be sorbed on cation exchangers, whereas phosphate and other interfering anions are eluted. The anionic fluoride and sulphosalicylate complexes of A1 can be separated by cation exchangers from metals that do not form the corresponding complexes.
6.2. Methods of determination The extraction method using 8-hydroxyquinoline is not very sensitive, but it is highly selective. The really sensitive methods for spectrophotometric determination of aluminium are based on ternary systems, including triphenylmethane reagents (mainly Chrome Azurol S and Eriochrome Cyanine R) and some surfactants.
6.2.1. 8-Hydroxyquinoline method Between pH 4.5 and 10, 8-hydroxyquinoline (oxine) forms the chelate AI(C9H6ON)3, which is sparingly soluble in water but dissolves readily in CHC13. The yellow extract of aluminium oxinate is the basis for the determination method [2,14]. Carbon tetrachloride and trichloroethylene are also used as extraction solvents. The absorption maximum of the chloroform extract is at 390 nm (e= 7.3103, a = 0.27). The absorption of oxine in CHC13 increases rapidly below 390 nm. Although oxine is a group reagent and reacts with many metals, the use of appropriate masking agents makes the method specific for aluminium. There are many variants of the oxine method, depending on the kinds of metals that accompany aluminium in the analyte sample. Large quantities of Fe(III) are usually extracted as the chloride, thiocyanate, cupferronate or HTTA complexes [9]. Smaller quantities of Fe may be masked with 2,2'dipyridyl, 1,10-phenanthroline (pH 4-6) [2], or with cyanide, after reduction to Fe(II). It is also possible to extract first Fe(III) oxinate at pH 2.5-3.0 [ 15], then A1 oxinate at pH 4.5-5.0. At pH 3 Fe(III) is extracted quantitatively, while no A1 is extracted. Hydrogen peroxide prevents oxine from reacting with Ti, V, Nb, U, and Ce. Cyanide masks Ni, Co, Cu, Zn, Cd, Ag, and Fe(II). EDTA or tartrate keeps aluminium in solution at higher pH values, at which it normally hydrolyses. The presence of EDTA does not interfere in the extraction of aluminium with oxine when the pH of the solution is above 8. Small amounts of heavy metals can be separated from aluminium by extraction as dithiocarbamates and dithizonates. Ti and Zr can be stripped from chloroform extracts of A1, Ti, and Zr oxinates by shaking with ammoniacal solution at pH 9.2 [9]. Vanadium and titanium can be separated from A1 by extracting the cupferronates from a 1 M H2804 medium with CHC13.
Reagents 8-Hydroxyquinoline (oxine): 1% solution in chloroform. Standard aluminium solution: 1 mg/ml. Dissolve 17.5900 g of KAl(SO4)z12H20 in water containing 5 ml of conc. H2804: dilute the solution to 1 litre with water in a standard flask. Working solution is given by suitable dilution of stock solution with -~0.01 M H2804. EDTA (disodium salt), 5% solution.
6.2. Methods of determination
85
Procedure To a solution containing not more than 60 lag of A1, add 2 ml of 5 % EDTA solution and 1 ml of 3 % H202 solution. After 5 min adjust the solution with ammonia to pH -- 9, add -- 0.1 g of Na2SO3 and --20 mg of KCN, and heat the solution to 70-80~ Cool the solution and readjust the pH to 9.0 +0.2 with -- 0.1 M HC1. Transfer the solution to a separating funnel, and extract the aluminium with two portions of the chloroform-oxine solution. Wash the combined extracts with two portions of water and make the solution up to the mark with the oxine solution in a 25 ml standard flask. Measure the absorbance of the extract at 390 nm, using as reference a reagent blank solution.
Note. During the extraction and washing in the separating funnel, the liquid must not be shaken too vigorously (lest a stable emulsion be formed).
6.2.2. Chrome Azurol S method Chrome Azurol S (CAS) (formula 4.18) reacts with aluminium ions to form (pH 4-7) a water-soluble blue complex which has been a basis for the determination of aluminium [ 1618]. The value of e (under the conditions specified in Procedure) is 5.2104 ( a - l . 9 ) at 545 nm. In the absence of acetate buffer, e values can be higher [16,17]. Hexamine buffer is recommended. The absorbance of the free reagent is insignificant at 545 nm. Solutions of the CAS-A1 complex do not obey Beer's law. The intensity of the colour of the complex depends on the concentration of CAS. The colour weakens with increasing concentration of acetate. Alkali-metal salts affect the colour and its stability. To compensate for this salt effect, corresponding amounts of the salts should be added to the reference calibration solutions [ 19]. Ascorbic acid, thioglycolic acid, or hydroxylamine are used to reduce Fe(III), which interferes. Copper is masked by thiosulphate. Before the determination of aluminium, Be, V, and Zr should be separated.
Reagents Chrome Azurol S (CAS), 0 . 1 % solution. Standard aluminium solution: 1 mg/ml. Preparation as in Section 6.2.1. Ascorbic acid: 1% solution, freshly prepared.
Procedure To a solution in dilute HC1, containing not more than 10 lag of A1, add 1 ml of ascorbic acid solution, and adjust the pH of the solution with ammonia to --2. After 5 min, dilute the solution with water to --15 ml, and add 2.5 ml of CAS solution and 1 ml of 20% sodium acetate solution. Adjust the pH of the solution with ammonia to 6.0 __ 0.2, dilute with water to 25 ml in a standard flask, and measure the absorbance of the solution at 545 nm, against a reagent blank as reference.
86
6. Aluminium
6.2.3. C h r o m e A z u r o l S - s u r f a c t a n t m e t h o d A considerable increase in the sensitivity of the determination of aluminium with Chrome Azurol S is observed in the presence of cationic or non-ionic surfactants, if present in sufficient molar excess with respect to the chromogenic reagent. The presence of surfactants gives rise to a considerable bathochromic shift (Fig. 6.1). The molar absorptivities in the presence of CTA or CP are in the range (1.1-1.3).105 (a~-4.4) at 610-640 nm, depending on the reaction conditions [20-23]. The cationic surfactant Zephiramine is also used sometimes [21,23,24]. The recommended pH values are similar to those for the binary system, i.e., 5-6.
|
~oo
430
500
5z.O
600 625
700
wavelength, nm
Fig. 6.1. Absorption spectra of Chrome Azurol S (CAS) (vs. water), (1), AI-CAS complex (vs. reagent solution) (2), and the ternary AI-CAS-CTA complex (3) (vs. reagent solution) (pH 5.3) A number of non-ionic surfactants was used for determination of aluminium with Chrome Azurol S. They include: Dispergator BO [21], OP-10 [25], Sintanol DS-7 and Sintanol DS-10 [25-27], and others [28]. The sensitivities are similar to those found with cationic surfactants. The values of A~, can be larger than 200 nm [25]. A number of metals [including Be, Ga, In, Sc, Fe(III), U, V, and Zr] interfere with the determination of A1. Anions that form complexes with A1 (e.g., fluoride, phosphate, citrate) prevent the formation of the ternary aluminium complex. Before the determination, A1 should be separated from interfering elements, or they should be masked.
Reagents Chrome Azurol S (CAS), l 1 0 -3 M (---0.05%) solution. Cetyltrimethylammonium bromide (or chloride) (CTA), 110 .2 M (--0.3%) solution. Standard aluminium solution. Preparation as in Section 6.2.1.
Procedure Place a sample solution in dilute HC1 (pH 1-2, 10-15 ml), containing not more than 5 gg A1, in a small beaker and add --10 mg of ascorbic acid. After 5 min add --2 ml of CAS solution, and adjust the pH to 5.3_+0.2 with dilute ammonia solution. Dilute to volume in a 25 ml standard flask, mix, and measure the absorbance of the solution at 620 nm vs. a reagent blank solution.
6.2. Methods of determination
87
6.2.4. Other methods Eriochrome Cyanine R (ECR) (formula 4.17), triphenylmethane reagent, is often used for determining aluminium, like the CAS presented above [29,30]. The optimum pH for the colour reaction lies within the rather narrow limits of 6.0-6.2. The absorptivity of the complex drops rapidly at higher or lower pH values [29]. The molar absorptivity of the complex is -~6.5.104 at 535 nm. Interfering Fe(III) can be reduced with ascorbic or thioglycolic acid. Also many other elements interfere [30]. The sensitivity of determining A1 increases markedly in the methods involving ECR and cationic surfactants (Zephiramine, CTA, CP) at pH 6.0-7.5, where ~ attains the values within (1.15-1.25) -105 at -~600 nm [31,32]. Pyroeateehol Violet (formula 4.16) is a popular reagent for determining aluminium [11,31,33-36]. The value of ~ is 6.3.104 at 580 nm (pH 6.5-7.2) [35]. A relatively small increase in sensitivity is observed in ternary systems with CTA, CP, or poly(vinylbenzyltriphenylphosphonium) chloride [37-39]. The ternary complex with Zephiramine can be extracted into CHCI3 or 1,2-dichloroethane (e ~- 9-104 at 590 nm) [40]. The extractive (xylene) method with the use of tridodecylethylammonium bromide is of very high sensitivity (~ = 1.7.105 at 613 nm [41]. Aluminium was also determined by the FIA technique using Pyrocatechol Violet [42]. Aluminon (ammonium aurintricarboxylate) (formula 6.1) was formerly an important reagent for aluminium (~-~ 2.104) [4,31,43]. It forms a sparingly soluble red chelate with A1 ions in acetate buffer. Protective colloids (e.g., gelatine) are necessary to stabilize the pseudo-solution.
COOH
HO
;#~IOOH / c!
1-100C
OH
(6.1)
(6.2)
Other triphenylmethane reagents include: Xylenol Orange [5,44-47], Methylthymol Blue (~; = 1.9.104) [48,49], Sulphochrome with cationic surfactant CP (~ = 1.0.105) [50], Chromoxane Blue B in the presence of CTA (~; = 1.2.105 at 645 nm) [51], and Chromal Blue G in the presence of CTA (~; = 1.6-105 at 660 nm) [52]. A number of azo reagents has been suggested for determination of aluminium, i.e., Stilbazo (~; = 7.4.104 at 570 nm) [53], Chromazol KS (~ = 3.5.104) [54-56] (in the presence of surfactant CP, ~; = 1.2.10s), Chlorophosphonazo I [57], Lumogallion (formula 6.2) ( e - 5.0.104 at 500 nm) [58], and Sulphonitrophenol S (propanol-acetic acid medium) [59].
88
6. Aluminium
Methods of determining aluminium with the use of Chrome Azurol S, Eriochrome Cyanine R, and Pyrocatechol Violet have been compared [60,61 ]. Among the 2,3,7-trihydroxyfluorones used as reagents for determination of A1 the best was 5-bromosalicylfluorone (t; = 7.5-104 at 540 nm) (formula 6.3) [62-64]. In the determination of A1 with phenylfluorone in the presence of CP (pH 5-6) a value of ~ = 1.14.105 at 560 nm was obtained [65]. Other organic spectrophotometric reagents used for the determination of A1. were: Alizarin S (formula 57.1) [66,67], ferron [68], salicyloylhydrazones [69], and haematoxyline in the presence of CTA [70,71]. The use of Bromopyrogallol Red in the presence of diphenylguanidine [72] and some cationic surfactants [73,74] has been proposed. An extractable (toluene) ion-associate of the aluminium-pyrocatechol complex and Brilliant Green is the basis of a very sensitive method (t; = 2.4.105) [75].
o~
0
oH
(6.3) Bi
6.3. Analytical applications The 8-hydroxyquinoline method was applied for determination of aluminium in: plant materials [15,76,77], soil extracts [76], silicate rocks and minerals [2], cast iron and steel [1,8,9,14], nickel- and copper alloys [1], chromium [78], beryllium [79], metallurgy products [80], titanium concentrates [7], and phosphates [81]. The Chrome Azurol S method was used to determine aluminium in: water [82], steel [83,84], uranium alloys [85], iron ores [86], and magnetic alloys [87]. Higher contents of aluminium (--10%) in magnesium and titanium compounds were determined by the differential spectrophotometry techniques [88] The methods involving Chrome Azurol S and surfactants were used for determining aluminium in: water [27,89-93], steel [94,95], copper alloys [26], magnesium alloys [21], chromium alloys [96], and titanium [3]. Trace amounts of aluminium were determined in tap water by means of CAS and CP (pH 5.7; 30% ethanol) using the flow-injection technique (FIA) [91 ]. The method with ECR was applied for the determination of aluminium in: biological materials [12,97], natural waters [31,98], plants and soils [99,100], steel samples [29], leadand tin alloys [101], and silicon tetrachloride [102]. The FIA technique was used for determination of aluminium, in the presence of a surfactant, in natural waters [32]. Aluminium was determined, with the use of Pyrocatechol Violet, in: water and soil [103,104], minerals [33], silica [105], steel and copper alloys [34], molybdenum and tungsten [11]. The FIA technique was applied for determining A1 in natural waters [ 106,107].
References
89
Determinations of aluminium with the use of various triphenylmethane reagents were carried out in: natural waters [47,108], soil extracts [44,109], silicate rocks [46,50], minerals [49], titanium and its compounds [5,48], copper alloys [45], glass and slags [110].
References 1. Burke K.E., Anal. Chem., 38, 1608 (1966). 2. Riley J.P.,Anal. Chim. Acta, 19, 413 (1958). 3. Tikhonov V.N., Karpeeva L.A., Zh. Anal. Khim., 33, 2267 (1978). 4. Herrmann M., Weber H., Z. Anal. Chem., 267, 13 (1973). 5. Tikhonov V.N., Zh. Anal. Khim., 20, 941 (1965). 6. Scribner W.G. et al., Anal. Chem., 37, 1136 (1965). 7. Nazarenko V.A., Shitareva G.G., Veshchikova N.A., Zavod. Lab., 47, No 6,19 (1981). 8. Villarreal R., Krsul J.R., Barker S.A.,Anal. Chem., 41, 1420 (1969). 9. Dagnall R.M., West T.S., Young P., Analyst, 90, 13 (1965). 10. Zolotov Yu.A., Demina L.A., Petrukhin O.M., Zh. Anal. Khim., 25, 1487 (1970). 11. Donaldson E.M., Talanta, 189, 905 (1971). 12. Seibold M., Z. Anal. Chem., 173, 388 (1960). 13. Korkisch J., Hazan J., Anal. Chem., 36, 2308 (1964). 14. Blazejak-Ditges D., Z. Anal. Chem., 246, 241 (1969). 15. Middleton K.R., Analyst, 89, 421 (1964). 16. Bohrer D, Gioda A., Binotto R., Anal. Chim. Acta 362, 163 (1998). 17. Martynov A.L., Novak V.L., Reznik B.E., Zh. Anal. Khim., 33, 51 (1978). 18. Kennedy J.A., Powell H.K., Anal. Chim. Acta, 184, 329 (1986). 19. Tikhonov V.N., Zh. Anal. Khim., 35, 49 (1980). 20. Nishida H., Z. Anal. Chem., 274, 50 (1974). 21. Tikhonov V.N., Yarkova L.V., Zavod. Lab., 41, 1180 (1975). 22. Tikhonov V.N., Ekaterinina L.A., Zh. Anal. Khim., 30, 1507 (1975). 23. Marczenko Z., Jarosz M., Analyst, 107, 1431 (1982). 24. Ohzeki K. et al.,Analyst, 113, 1545 (1988). 25. Savvin S.B., Czernova R.K., Kudryavtseva L.M., Zh. Anal. Khim., 33, 2127 (1978). 26. Nemodruk A.A., Arevadze N.G., Abalakina V.M., Zavod. Lab., 45, 494 (1979). 27. Nemodruk A.A. et al., Zh. Anal. Khim., 37, 1028 (1982). 28. Nemodruk A.A., Arevadze N.G., Supatashvili G.D., Zh. Anal. Khim., 35, 1511 (1980). 29. Wille K.D., Z. Anal. Chem., 250, 23, (1970). 30. Shakhverdi N.M., Naumova O.N., Tumanov A.A., Zavod. Lab., 55, No 3, 9 (1989). 31. RCyset O.,Anal. Chim. Acta, 178, 223 (1985). 32. RCyset O., Anal. Chem., 59, 899 (1987). 33. Wilson A.D., Sergeant G.A.,Analyst, 88, 109 (1963). 34. Mustafin I.S., Molot L.A., Arkhangel'skaya A.S., Zh. Anal. Khim., 22, 1808 (1967). 35. Tikhonov V.N., Bakhtina V.V., Zh. Anal. Khim., 39, 2126 (1984). 36. Kramer J.R., Gleed J., Gracey K., Anal. Chim. Acta, 284, 599 (1994). 37. Cluster J.E., Dagnall R.M., West T.S., Talanta, 17, 13 (1970). 38. Tananayko M.M., Vdovenko O.L., Zh. Anal. Khim., 30, 1095 (1975); 32, 1121 (1977). 39. Matsushita T., Kaneda M., Shono T., Anal. Chim. Acta, 104, 145 (1979). 40. Korenaga T., Motomizu S., T6ei K., Talanta, 27, 33 (1980). 41. Shijo Y., Bull. Chem. Soc. Jpn., 48, 2793 (1975). 42. Kobayashi J., Baba M., Miyazaki M., Anal. Sci., 10, 287 (1994). 43. Cabrera F., Madrid L., de Arambarri P., Analyst, 106, 1296 (1981).
90 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59.
6. Aluminium
Pritchard D.T., Analyst, 92, 103 (1967). Mochizuki T., Kuroda R., Z. Anal. Chem., 311, 11 (1982). Mochizuki T., Toda Y., Kuroda R., Talanta, 29, 659 (1982). Edwards A.C., Cresser M.S., Talanta, 30, 702 (1983). Tikhonov V.N., Zh. Anal. Khim., 21, 275 (1966). Zolotukhina N.M., Erenpreys T.M., Zavod. Lab., 45, 297 (1979). Chernova P.K., Sukhova L.K., Amelin V.G., Zh. Anal. Khim., 33, 1934 (1978). Martire C., Hainberger L., Mikrochim. Acta, 1985 II, 223. Miyawaki M., Uesugi K., Mikrochim. Acta, 1985 III, 319. Wetlesen C.U.,Anal. Chim. Acta, 26, 191 (1962). Basargin N.N., Yakovlev L.Ya., Morozova O.N., Zavod. Lab., 40, 1322 (1974). Stolyarov K.L., Smirnova G.M., Basargin N.N., Zavod. Lab., 49, No 1, 10 (1983). Shao-pu L., Analyst, 107, 428 (1982). Ying-quan Z., Liu Z., Jun-yi L., Talanta, 30, 291 (1983). Pyatnitskii I.V., Boryak A.K., Kolomiets L.L., Zh. Anal. Khim., 51, 2199 (1986). Savvin S.B., Petrova T.V., Mongush K.D., Zh. Anal. Khim., 33, 1552 (1978); 35, 54 (1980). 60. Hawke D.J., Powell H.K.,Anal. Chim. Acta, 299, 257 (1994). 61. Hawke D.J., Powell H.K., Simpson S.L.,Anal. Chim. Acta, 319, 305 (1996). 62. Nazarenko V.A., Kostenko I.G., Biriuk E.A., Zh. Anal. Khim., 34, 1942 (1979). 63. Biriuk E.A., Kostenko I.G., Zavod. Lab., 46, 293 (1980). 64. Biriuk E.A., Kostenko I.G., Pshetakovskaya N.A., Zavod. Lab., 49, No 7, 20 (1983). 65. Albota_.A., Guculak R.B., Albota N.K., Ukr. Khim. Zh., 51, 1290 (1985). 66. King H.G., Pruden G.,Analyst, 93, 601 (1968). 67. Hernadez-Mendez J. et al.,Anal. Chim. Acta, 149, 379 (1983). 68. Goto K. et al., Talanta, 21, 183 (1974). 69. Gallego M., Valcarcel M., Garcia-Vargas M., Analyst, 108, 92 (1983). 70. Zaki M.T., E1-Didamony A.M.,Analyst, 113, 577 (1988). 71. E1-Sayed A.Y., Fresenius'J. Anal. Chem., 355, 29 (1996). 72. Rudzitis J. et al., Chem. Anal. (Warsaw), 26, 1045 (1981). 73. Wyganowski C., Kolczyfiska M., Microchem. J., 27, 43 (1982). 74. Wyganowski C., Motomizu S., T6ei K., Mikrochim. Acta, 1983 I, 55. 75. Biriuk E.A., Vinarova L.I., Ryavitskaya R.V., Ukr. Khim. Zh., 47, 760 (1981). 76. Paul J., Mikrochim. Acta, 1966, 1075. 77. Frink C.R., Peaslee D.E.,Analyst, 93, 469 (1968). 78. Tumanov A.A., Petukhova V.G., Zavod. Lab., 35, 654 (1969). 79. Pollock E.N., Zopatti L.P., Anal. Chim. Acta, 28, 68 (1963). 80. Angermann W. et al., Chem. Anal. (Warsaw), 16, 261 (1971). 81. Costadinnova L., Nedeltcheva T., Anal. Lab., 5, 46 (1996). 82. Molina-Diaz A., Herrador-Mariscal J.M., Pascual-Reguera M.I., Talanta, 40, 1059 (1993). 83. Kharlamov I.L., Erenina G.V., Borcheva T.A., Zavod. Lab., 38, 8 (1972). 84. Popov V.A. et al., Zavod. Lab., 56, No 2, 103 (1990). 85. Mal'tseva L.S., Kubareva L.V., Zavod. Lab., 35, 1299 (1969). 86. Bhargava O.P., Hines W.G.,Anal. Chem., 40, 413 (1968). 87. Babenko A.S., Volodchenko T.T., Zavod. Lab., 35, 650 (1969). 88. Tikhonov V.N., Zh. Anal. Khim., 19, 1204 (1964). 89. Sampson B., Fleck A., Analyst, 109, 369 (1984). 90. Ohzeki K., Uno T., Nukatsuka I., Ishida R., Analyst, 113, 1545 (1988).
References
91. Bouzid B., Macdonald A.M.,Anal. Chim. Acta, 207, 337 (1988). 92. Malcolme-Lawes D.J., Wong K.H., J. Autom. Chem., 13, 147 (1991). 93. Savranskii L.I., Nadzhafova O.Yu., Ukr. Khim. Zh., 58, 183 (1992). 94. Zakharova T.N. et al., Zavod. Lab., 57, No 12, 1 (1991). 95. Kurbatova V.I., Fokina L.S., Zakharova T.N., Zavod. Lab., 54, No 9, 3 (1988). 96. Tikhonov V.N., Zh. Anal. Khim., 35, 461 (1980). 97. Valencia M.C., Boudra S., Bosque-Sendra J.M., Anal. Chim. Acta, 327, 73 (1996). 98. Dougan W.K., Wilson A.I., Analyst, 99, 413 (1974). 99. Reis B.F. et al., Anal. Chim. Acta, 107, 309 (1979). 100. Zagatto E.A. et al.,Anal. Chim. Acta, 261, 59 (1992). 101. Zhenpu Wang, Cheng K.L., Talanta, 29, 551 (1982). 102. Marczenko Z., Kasiura K., Mojski M., Chem. Anal. (Warsaw), 16, 203 (1971). 103. Samaritan J.M. et al., J. Environ. Anal. Chem., 50, 173 (1993). 104. Benson R.L., Worsfold P.J., Sweeting F.W., Anal. Chim. Acta, 238, 177 (1990). 105. Sugawara K.F., Yao-Sin S., Anal. Chim. Acta, 80, 143 (1975). 106. RCyset O.,Anal. Chim. Acta, 185, 75 (1986). 107. Quintela I., Gallego M., Valcarcel M.,Analyst, 118, 1199 (1993). 108. Lowe R.D., Snook R.D., Anal. Chim. Acta, 250, 95 (1991). 109. Zolotov Yu.A. et al., Anal. Chim. Acta, 308, 386 (1995). 110. Mondal J.K., Roy S.K.,Analyst, 119, 1377 (1994).
91
Chapter 7. Antimony Antimony (Sb, at. mass 121.75) occurs in compounds in the oxidation states -III (stibine SbH3), III and V. The compounds of Sb(III) are the most stable. The Sb 3+ ions hydrolyse at pH values as low as -~1. The hydroxide Sb(OH)3 dissolves at pH--10 to form the antimonite ion, SbO2-. Antimony(V) is more acidic than Sb(III). Antimony (III and V) form sulphide-, halide-, tartrate-, and oxalate complexes.
7.1. Methods of separation and preconcentration 7.1.1. Extraction The antimony(V) chloride complex can be extracted into DIPE from 1-10 M HC1 [1]; about 99% extraction is obtained in 5-7 M HC1. It is convenient to extract Sb(V) from 2M HC1 (94% extraction) since Fe(III) is not extracted under such conditions. Iron(III) can be separated by extraction from 6-7 M HC1 before the Sb(III) is oxidised to Sb(V). The chloride complex of Sb(V) can be extracted with non-polar solvents in the presence of amines, e.g. tribenzylamine or tridodecylamine. The antimony(III) can be extracted with 20% TBP from 2M HC1 and 1 M MgC12 [3]. The iodide SbI3 is extracted by benzene from 5M H2SO4 and 0.005-0.05 M KI [4-6]. Antimony(III) is then re-extracted with 0.5 M H2SO4. Sb(III) was also extracted with benzene from acid (H2SO4) iodide solution [7], and with p-toluidine in the presence of bromide [4,6,8]. Extraction of the Sb(III) dithiocarbamate complexes from acid media allows antimony to be separated from many metals [9-11]. A preliminary extraction of Bi and Cu dithiocarbamates can be carried out after oxidation of Sb(III) to Sb(V). Antimony was also extracted as the complex with cupferron [ 12] or BPHA [ 13]. Sb(III) and As(HI) can be extracted with bis(2-ethylhexyl)dithiophosphoric acid (0.1 M) in heptane from 2-4 M HC1 in the presence of iodide. Only Sb(III) is re-extracted with 12 M HC1 [ 14]. The reagent has been applied for isolation of Sb in partition chromatography [15]. Also diethyldithiophosphoric acid has been recommended for the separation of Sb(III) and As(III) [16]. In the presence of Bi and Sn, antimony was determined after extraction (CHC13) with cyclic thiourea derivatives [17]. Sb(lJI) was also extracted with the use of the crown ether 18-crown-6 [ 18].
7.1.2. Precipitation Trace amounts of antimony are separated from an acid medium (HNO3, H2504) as hydrated antimonic acid with MnO2 aq. as the collector [ 19-22]. The latter is formed in situ by the slow reaction of a hot solution of Mn 2+ with MnO4-. The MnO2 aq. collector can also be formed by the reaction of MnO4- with ethanol [21]. Although Sb is quantitatively precipitated within the pH range 1-7, the reaction is usually carried out at pH -~1 to prevent co-precipitation of other metals such as Bi, As, Au, Fe(III), TI(III), Pb, and Cu. Tin is precipitated with Sb. Fluoride interferes in the precipitation of Sb with MnO2 aq. The
7.2. Methods of determination
93
precipitate of MnO2 aq. with Sb is dissolved in HC1 (1 + l) containing some H202. The filter paper can be mineralized in conc. H2804 containing some conc. HNO3. Trace amounts of Sb can be co-precipitated with Fe(III) [23], A1 [22], and Zr [24,25]. In a flotation method, Fe(OH)3, surfactant, and air bubbling have been applied [26]. Traces of Sb are precipitated with HzS from 0.5-1 M HC1 or H2804 (Cu or Mo may be used as collectors). Tin does not precipitate in the presence of oxalic acid, while W and V can be masked by tartaric acid. Traces of antimony in tellurium have been co-precipitated with a small amount of tellurium as a carrier [27].
7.1.3. Distillation and other methods Traces of Sb have been separated as the volatile hydride SbH3 [28,29]. Antimony is reduced in fairly concentrated HC1 with amalgamated zinc. The volatile SbC13 is distilled from 11 M HC1. Under suitable conditions Sb is separated from As and Sn [30]. Antimony was separated from Bi on a cation exchanger in a tartrate medium [31]. Mixtures of antimony and tin were separated as malonates on the anion exchanger, Amberlite IRA-400. The chloride complex of Sb(V) is retained on the strongly basic anionexchanger. Trace amounts of Sb were sorbed on silica gel, saturated with a mixture of the amine Aliquat 336 and Eriochrome Black T [32]. Antimony and bismuth are sorbed at pH-1. Sb(III) and Sb(V) can be separated by passing a solution through a column of polyurethane foam saturated with DDTK; only Sb(V) is retained [33]. Sb(III) was sorbed from an iodide medium by polyurethane foam saturated with dithizone [34].
7.2.
M e t h o d s of d e t e r m i n a t i o n
In the methods of Sb determination use is made of ion-associates SbC16- with Rhodamine B and other basic dyes. The methods are highly sensitive and selective. A simple iodide method is commonly used to determine higher antimony concentrations.
7.2.1. Rhodamine B method With Rhodamine B (formula 4.29) the antimony(V) chloride complex, SbC16-, forms a sparingly water-soluble ion pair, which is extractable into benzene or DIPE. The violet-pink solutions of the complex in these solvents are the basis of a sensitive spectrophotometric method for antimony [28,35]. Rhodamine B dissolves in acid, giving a pink solution, but is insoluble in benzene and DIPE. The molar absorptivity of the ion associate in DIPE ~ = 9.7104 (a = 0.80) at )~max 552 nm. The benzene solution of this compound has )~maxof 565 nm. The solubility of [RB+][SbC16 -] is rather low, the concentration of Sb in the benzene phase must not exceed 2 gg/ml. The solubility in DIPE is much higher. Ceric sulphate is most often used as oxidant since it oxidizes Sb(III) to Sb(V) quickly in 6 M HC1, even in the cold. Since the excess of Ce(IV) could oxidise RB, it is reduced with hydroxylamine, which does not reduce the Sb(V) under the conditions of the reaction. That Ce(IV) is reduced by the HC1 itself is indicated by the bleaching of the yellow solution even before the addition of NHzOHHC1. Hydroxylamine reduces, first of all, the chlorine formed, which, if left in the solution, would oxidise the Rhodamine B added later. As an alternative
94
7. Antimony
to Ce(IV), sodium nitrite can be used for oxidizing Sb(III) (the excess is reduced with urea) [39]. Metal ions forming chloride complexes which give the same reactions as Sb(V) with RB interfere in the determination. These are: Au(III), Tl(III). Ga([II), and Fe(III). Gold can be separated after reduction to the element with sulphite. Gallium and iron can be separated by extraction as chloride complexes before the oxidation of antimony to Sb(V). Small amounts of Fe(III) are masked with phosphoric acid. A convenient method of determination consists in the extraction of HSbC16 by DIPE from 1.5-2 M HC1. The ether extract is shaken with an aqueous solution of RB to form a coloured complex in the ether. Fe(III) is not extracted by DIPE from 1.5-2 M HC1. If Sb(V) is not first extracted into DIPE, Rhodamine B is added after the excess of the oxidising agent has been reduced and the solution is then extracted with benzene or DIPE. Alcohol can be added to clear any turbidity in the benzene extract.
Reagents Rhodamine B (RB), 0.02% solution in 1 M HC1. Standard antimony solution: 1 mg/ml. Dissolve 2.668 g of potassium antimonyl tartrate (SbO)KC4H406 in HC1 (1+1) and dilute the solution to 1 1 with this acid. Working solutions are obtained by suitable dilution of the stock solution with HC1 (1 + 1). Ceric(IV) sulphate, 3 % solution in 0.5 M H2SO4. Hydroxylamine hydrochloride, 1% solution. The solution is unstable. Procedure
Separation of Sb by co-precipitation with Mn02 aq. To the chloride-free sample solution, containing 3 ml of conc. HNO3 per 100 ml of the solution, and heated almost to boiling, add 1 ml of 1% KMnO4 solution and 2 ml of 1% Mn(NO3)2 solution. Keep the solution just below boiling for 30 min. Filter off the precipitate and wash with hot dilute HNO3 (1 + 100). Dry the filter paper and the precipitate and ignite. Fuse the residue with 0.3 g of Na202 and a granule of NaOH in a small nickel crucible. Heat the melt till dark red. Leach the cooled melt with hot water, transfer all the contents of the crucible to a beaker, and acidify with 5 ml of conc. HC1. Evaporate the solution to a suitable volume. Separation of Sb by extraction. To the sample solution containing not more than 25 gg of Sb add sufficient conc. HC1 for its concentration in the solution to be 6 M (the solution volume is 10-15 ml). Add 5 drops of the Ce(SO4)2 solution and stir well. After 5 min, add 5 drops of the NH2OH.HC1 solution and stir well. After 2 min dilute the solution with two volumes of water, transfer it to a separating funnel, and shake with two portions of DIPE for 30 sec. Wash the extract with two portions of 1 M HC1. Determination of Sb. To the separating funnel with the ether solution of the antimony(V) chloride complex add 3 ml of the RB solution and shake. Transfer the coloured ether extract to a 25 ml standard flask, add DIPE to the mark, mix, and measure the absorbance at 552 nm using the solvent as a reference. Note. When using benzene as a solvent proceed as follows: 2 min after the addition of NH2OH.HC1, add 3 ml of the RB solution, and dilute the solution with water so that the concentration of HC1 is 2M. Transfer the solution to the separating funnel and shake for 1 rain with 2 or 3 portions of benzene. Place the combined benzene extracts in a volumetric flask. If the extract is turbid, add 1 ml of ethanol. Dilute to the mark with benzene, mix, and measure the absorbance of the solution at 565 nm against benzene.
7.2. Methods of determination
95
7.2.2. Iodide method Antimony(III) forms a greenish-yellow complex with iodide in sulphuric acid medium. The colour intensity increases with increasing iodide concentration up to 5% KI, above which it remains constant. The concentration of sulphuric acid in the final solution should be 1.5-2.5 M. To prevent liberation of iodine by atmospheric oxygen, ascorbic acid, hypophosphite, or sulphite are added as reducing agents. The aqueous acid solution of the complex of SbI3 exhibits 2 absorption maxima: the smaller one at 425 nm and a much higher one at 330 nm. The value of e at 425 nm is 4.0103, a =0.033. Bismuth also forms a yellow iodide complex, and thus interferes in the determination of antimony. In a solution containing as little as 1% KI bismuth gives a colour reaction while antimony does not. By measuring the absorbances of sample solution containing low (1%) and high (5%) concentrations of KI, it is possible to determine both Bi and Sb. Antimony can be separated from bismuth by extraction into benzene from iodide medium. From 5 M H2804 and 0.05 M KI solution, SbI3 is extracted in a good yield, whereas the bismuth complex is not extracted at all. Thallium is precipitated as TI(I) and separated by filtration [36]. Copper is masked with thiourea. The extraction of SbI3 with benzene from 5 M H2804 medium in the presence of small excess of KI enables to determine Sb by the sensitive amplification method. From the washed benzene extract SbI3 is re-extracted with water. In this aqueous extract, the iodide is oxidised to iodate with bromine. After removal of excess of bromine, the IO3- ions react with KI to yield iodine which is determined by its colour reaction with starch (see Section 25.2.1). Thus 18 iodine atoms are formed for each Sb atom (in SbI3). The molar absorptivity in this method is --3.0.105 (a = 2.6).
Reagents Potassium iodide, 40% solution. Standard antimony solution: 1 mg/ml. The solution may be prepared either from potassium antimonyl tartrate (Section 7.2.1) or in the following manner. Dissolve 0.1000 g of powdered antimony metal in 25 ml of conc. H2804. Dilute the cooled solution with water while stirring, cool, and make up to 100 ml in a standard flask. Working solutions are obtained by suitable dilution of the stock solution with 0.5 M H2804. Ascorbic acid, 2% solution, freshly prepared.
Procedure To the sample solution in a 25-ml volumetric flask containing not more than 0.5 mg of Sb, add 5 ml of H2804 (1 + 1), 2 ml of 2% ascorbic acid solution, and 5 ml of KI solution. Dilute the solution to the mark with water and stir well. After 5 min, measure the absorbance of the yellow solution at 425 nm, using water as a reference.
7.2.3. Other methods Sensitive extraction spectrophotometric methods for determining Sb have been based on the ion-pair formation between SbC16- and the basic triphenylmethane dyes [37]. Brilliant Green (E=7.0-104) [3,37-46], Crystal Violet [25,37,47-49], Methyl Violet [12,37], Methyl
96
7. Antimony
Green, and Malachite Green [37] are used. Antimony has also been determined with the use of Safranine T [50], Methylene Blue [51,52], and Toluidine Blue (13=8.1.104) [53]. Antimony was determined in a benzene extract with the use of Rhodamine 6G (xanthene dye) [7]. The anionic complex of Sb(III) with mandelic acid forms with Malachite Green an associate which is extractable into chlorobenzene from weakly acid solutions (13= 6.1.104) [54]. Mandelic acid and other organic reagents have been applied for the joint determination of Sb(m) and Sb(V) [55,56]. Methylfluorone is recommended for the spectrophotometric determination of antimony [5,57,58]. In a weakly acidic medium (pH-~2), the orange Sb(IlI)-methylfluorone complex [which exists as a stable sol in the presence of gelatine or poly(vinyl alcohol)], is formed (13= 4.0.104 at 530 nm). Dibromophenylfluorone allows one to determine Sb in the presence of Bi [59]. Sb was determined with the use of vanillylfluorone in the presence of poly(vinyl alcohol) [60]. A number of azo reagents have been proposed for determination of Sb, e.g., PAN (CHC13, 13= 1.3.104) [61] and other pyridylazo reagents and their bromo-derivatives [62-66]. Other organic reagents have been used in determination of Sb, i.e., Bromopyrogallol Red (in the presence of CTA, (13=3.5.104 at 560 nm) [67], Pyrocatechol Violet [6,68,69] AgDDTK (with SbH3) (13=1.44.104) [70], Chrome Azurol S [71], and 2,2'-diquinoxalyl [with Sb(V)] [72].
7.3. Analytical applications The method based on the use of Rhodamine B has been applied for determination of antimony in sea water [21], rocks [28], arsenic [74], and titanium dioxide [35]. The iodide method was used for determination of antimony in: alloys and pharmacy products [75], steel [76], lead [1], white metals [77], and lubricating oils [78]. Stibine was determined in a gas mixture, by the iodide method, after oxidation to Sb(III) [79]. Methods involving triphenylmethane dyes were applied in determination of antimony in: air [74], water [44], silicates, plants, sewage and waste waters [25], copper-zinc and coppernickel alloys [48], steel [50], lead [12], silver and gold [42], palladium [45], and tellurium [27]. Antimony was determined in duralumin alloys and steel with the use of Rhodamine 6G [7]. Antimony was determined in coal and steel with the use of mandelic acid [80]. Phenylfluorone derivatives were applied in determination of Sb in non-ferrous metal alloys [81]. Azobenzene and its derivatives were used in determinations of Sb in ores and bronzes [82].
References 1. Bassett J., Jones J.C., Analyst, 91, 176 (1966). 2. Alian A., Sanad W., Talanta, 14, 659 (1967). 3. Yadav A.A., Khopkar S.M., Bull. Chem. Soc. Jpn., 43, 693 (1971). 4. Grimanis A.P., Hadzistelios I.,Anal. Chim. Acta, 41, 15 (1968). 5. Koch O.G., Z. Anal. Chem., 265, 29 (1973). 6. Tsukahara I., Sakakibara M., Tanaka M., Anal. Chim. Acta, 92, 379 (1977). 7. Nalini S., Balasubramanian N., Ramakrishna T.V., Fresenius'J. Anal. Chem., 348, 769 (1994).
References
97
8. Skripchuk V.G., Zh. Anal. Khim., 43, 1803 (1988). 9. Kovacs E., Guyer H., Z. Anal. Chem., 186, 267 (1962); 208, 255 (1965). 10. Biriuk E.A., Zavod. Lab., 30, 651 (1964). 11. Mok W.M., Wai C.M., Talanta, 35, 183 (1988). 12. Cyrankowska M., Downarowicz J., Chem. Anal. (Warsaw), 10, 67 (1965); 12, 137 (1967). 13. Lyle S.J., Shendrikar A. D.,Anal. Chim. Acta, 36, 286 (1966). 14. Yukhin Yu. M., Sergeeva V.V., Litvinov V.P., Zavod. Lab., 45, 798 (1979). 15. Vin Y.Y., Khopkar S.M., Mikrochim. Acta, 107, 49 (1992). 16. Hayashi K. et al., Anal. Sci., 2, 347 (1986). 17. Presnyak I.S., Shelikhina E.I., Antonovich V.P., Nazarenko V.A., Zh. Anal. Khim., 45, 1548 (1990). 18. Vibhute R.G., Khopkar S.M., Talanta, 36, 957 (1989). 19. Ogden D., Reynolds G.F.,Analyst, 89, 538 (1964). 20. Reynolds G.F., Tyler F.S., Analyst, 89, 579 (1964). 21. Portmann J.E., Riley J.P., Anal. Chim. Acta, 35, 35 (1966). 22. Tiptsova-Yakovleva V.G. et al., Zh. Anal. Khim., 25, 686 (1970). 23. Inoue Y., Munemori M., Bull. Chem. Soc. Jpn., 53, 926 (1980). 24. Adamiec I., Marczenko Z., Chem. Anal. (Warsaw), 20, 985 (1975). 25. Abu-Hilal A.H., Riley J.P.,Anal. Chim. Acta, 131, 175 (1981). 26. Nakashima S., Bull. Chem. Soc. Jpn., 54, 291 (1981). 27. Busev A.I. et al., Zh. Anal. Khim., 20, 812 (1965). 28. Schnepfe M.M., Talanta, 20, 175 (1973). 29. Cabredo Pinillos S., Sanz Asensio J., Galban Barnal J., Anal. Chim. Acta, 300, 321 (1995). 30. Patek P., Mikrochim. Acta, 1969, 282. 31. Sulcek Z., B6seova M., Dole_al J., Coll. Czech. Chem. Comm., 34, 787 (1969). 32. Przeszlakowski S., Kocjan R., Cukrowski I., Chem. Anal. (Warsaw), 31,735 (1986). 33. Valente I., Boven H.J.,Analyst, 102, 842 (1977). 34. Raychaudhuri A., Roy S.K., Talanta, 41, 171 (1994). 35. Jablonski W.Z., Watson C.A.,Analyst, 95, 131 (1970). 36. Maurice M.J., Van Lingen R.L.,Anal. Chim. Acta, 28, 91 (1963). 37. Kish P.P. et al., Zh. Anal. Khim., 28, 1746 (1973); 29, 102 (1974). 38. Burke R.W., Menis O., Anal. Chem., 38, 1719 (1966). 39. Fogg A.G. et al., Analyst, 94, 768 (1969). 40. Kerr G.O., Gregory G.R., Analyst, 94, 1036 (1969). 41. Fogg A.G., Burgess C., Burns D.T.,Analyst, 98, 347 (1973). 42. Tayurskii V.A., Sedykh T.P., Zavod. Lab., 49, No 7, 6 (1983). 43. Burns D.T., Chimpalee D., Bullick H.J., Anal. Chim. Acta, 284, 195 (1993). 44. Sharma M., Patel K.S., Int. J. Environ. Anal. Chem., 50, 63 (1993). 45. Potapenko L.I., Babkina T.A., Zavod. Lab., 58, No 10, 4 (1992). 46. Abrutis A.A., Zh. Anal. Khim., 46, 842 (1991). 47. Sorokin G.Kh., Lomonosov S.A., Zavod. Lab., 40, 23 (1974). 48. Shevchuk I.A., Baskin V.N., Zaitsev S.N., Zavod. Lab., 57, No 1, 18 (1991). 49. Shevchuk I.A., Zhan L., Ukr. Khim. Zh., 55, 267 (1989). 50. Burgess C., Fogg A.G., Burns D.T.,Analyst, 98, 605 (1973). 51. Kish P.P., Onishchenko Yu. K., Zh. Anal. Khim., 23, 1651 (1968). 52. Bastrakova E.V., Popova T.V., Zavod. Lab., 56, No 3, 1 (1990). 53. Abrutis A.A. et al., Zh. Anal. Khim., 34, 1997 (1979).
98
7. Antimony
54. Sato S. et al.,Anal. Lett., 16, 827 (1983). 55. Sato S., Talanta, 32, 341 (1985). 56. Sato S., Uchikawa S., Anal. Sci., 2, 47 (1986). 57. Mayer S., Koch O.G., Z. Anal. Chem., 179, 175 (19,,_6!). 58. Asmus E., Brandt K., Z. Anal. Chem., 208, 189 (1965). 59. Antonovich V.P. et al., Zh. Anal. Khim., 33, 458 (1978). 60. Moil I. et al., Talanta, 38, 343 (1991). 61. Rakhmatullaev K., Tashmamatov Kh., Zh. Anal. Khim., 29, 2402 (1974). 62. Gusev S.I., Poplevina L.V., Pesis A.S., Zh. Anal. Khim., 22, 731 (1967). 63. Xing-Chu Qiu et al., Mikrochim. Acta, 1989 I, 349. 64. Qiu X., Liu G., Zhu Y., Int. J. Environ. Anal. Chem., 34, 99 (1988). 65. Shen N., Chu W., Wei F., Zhu Y., Chem. Anal. (Warsaw), 33, 527 (1988). 66. Qiu X., Zhu Y., Liu G., Mikrochim. Acta, 1989 I, 349. 67. Nemcova I. et al., Microchem. J., 30, 39 (1984). 68. Bailey B.W., Chester J.E., Dagnall R.M., West T.S., Talanta, 15, 1359 (1968). 69. Hayashi K. et al., Anal. Sci., 3, 333 (1987). 70. Hulanicki A., G__b S., Chem. Anal. (Warsaw), 15, 1089 (1970). 71. Gao H.W., Zhang P.F.,Analyst, 119, 2109 (1994). 72. Baranowska I., Chem. Anal. (Warsaw), 31, 245 (1986). 73. Luke C.L., Anal. Chem., 31, 1680 (1959). 74. De Souza T.L., Kerbyson J.D.,Anal. Chem., 40, 1146 (1968). 75. Barve A.D., Desai G.S., Shinde V.M., Bull. Chem. Soc. Jpn., 66, 1079 (1993). 76. Blazejak-Ditges D., Klingeleers H., Z. Anal. Chem., 248, 18 (1969). 77. Dym A.,Analyst, 88, 232 (1963). 78. Norwitz G., Galan M.,Anal. Chim. Acta, 61,413 (1972). 79. Gann W., Z. Anal. Chem., 221, 254 (1966). 80. Sato S., Talanta, 32, 447 (1985). 81. Novikova I.S. et al., Zavod. Lab., 57, No 12, 9 (1991). 82. Kolesnikova A.M., Lazarev A.I., Zh. Anal. Khim., 49, 385 (1994).
Chapter 8. Arsenic Arsenic (As, at. wt. 74.92) occurs in its compounds in the oxidation states -HI (arsine, ASH3), HI (arsenite), and V (arsenate). Arsenic (HI and V) are amphoteric, but with much more acidic than basic character. The sulphides are characteristically capable of yielding soluble complexes (thio-salts). Arsenic(V) forms heteropoly acids.
8.1. Methods of separation and preconcentration 8.1.1. Extraction Arsenic(Hi) chloride can be extracted into CC14, CHC13, or C6H6 from 8-12 M HC1 [1,2]. GeC14 is co-extracted with AsC13; other elements (e.g. Se, Sb, Bi) have very low distribution coefficients. Arsenic and germanium may be separated from each other by extraction after oxidation of the former to As(V). As(Ill) is stripped from the organic solvent with dilute HC1, water, or dilute ammonia solution. As(HI) can also be extracted as AsBr3 [3], or AsI3 [4-6]. A chloroform solution of diethylammonium DDTC (formula 4.37) extracts As(HI), Sn(II), and Sb(llI) from 1-5 M H2SO4 medium. Arsenic(V), Sn(IV), and Sb(V) do not react with DDTC. After Cu, Bi, and Hg have been extracted, iodide and ascorbic acid are added to the aqueous solution and As(Ill) is extracted. The DDTC method enables to separate As from Ge in the presence of oxalic acid. Pyrrolidinedithiocarbamate is also recommended for separation of As [7-9]. A hexane solution of diethyldithiophosphoric acid extracts As and Sb from 1-2 M H2SO4, but only Sb is extracted at pH 1.3-2.5 [10]. As(V) has been separated from a number of elements by extraction into butanol from acidic medium as the molybdoarsenic heteropoly acid [ 11 ]. This acid has been extracted with solutions of some high molecular-weight amines in 1,2-dichloroethane [ 12]. As(Ill) has been extracted from iodide and chloride solutions by means of a benzene solution of diphenyl(2-pyridyl)methane [13]. Dialkyltin solutions in CHC13 have been proposed for extraction of As(V) [ 14-16].
8.1.2. Distillation The separation of arsenic as the toxic gas arsine, ASH3, is the first step in both the Gutzeit method and the Ag-DDTC method for determining As. Both methods are discussed later. Arsenic has also been separated as AsH3 before its determination as arsenomobdenum blue [17,18]. Normally, arsenic is reduced by hydrogen in statu nascendi which is formed on dissolving zinc in HC1 (3-6 M), but it can also be reduced electrolytically [18]. The AsH3 generated is carried over in the hydrogen stream into an alkaline iodine absorption solution. The distilled AsH3 was also absorbed on solid mercury(II) iodide, from which arsenic was then removed with iodine solution. Arsenic is normally separated as AsC13. Before being distilled from 5-7 M HC1 As(V) is reduced to as(l/I) by means of hydrazine. Only GeCI4 (b.p. 86 ~ and Se and Te chlorides distil along with AsC13 (b.p. 130 ~ Stannic chloride (b.p. 115 ~ is not distilled in the
100
8. Arsenic
presence of phosphoric acid. When the sample solution contains SbC13 (b.p. 220 ~ the distillation of AsC13 should be carried out at below 110 ~ Usually distillation is continued till a half of the initial volume remains in the distilling flask. The distillate is collected either in water or dilute HNO3, or in an alkaline iodine or H202 solution. Arsenic(Ill) may also be distilled from HBr [19] or HF [20] medium.
8.1.3. Precipitation and other methods Traces of As(V) are precipitated as FeAsO4 with Fe(OH)3 as the collector, by adding ammonia to an acid solution till the pH reaches 8-9 [21]. Arsenic(V) can be co-precipitated with MgNH4PO4 [22]. Traces of As have been precipitated from strongly acid solution as the sulphide by use of thioacetamide and with Mo as the collector [23]. Thionalide has also been used to co-precipitate trace amounts of As [25]. Thionalide deposited on silica gel retains As(Ill) at pH 6.5-8.5, while As(V) passes through the column [26]. Separation of As(Ill) from As(V) in ground waters by means of anion exchanger in acetate form has been proposed [27,27a]. Arsenic(V) is retained in the anion exchanger bed, whereas As(Ill) passes through. As(V), P(V), and Si were also separated on ion exchange columns [28].
8.2. Methods of determination The arsenomolybdenum blue method is the most widely used. The method using the reaction of AsH3 with Ag-DDTC is less sensitive. In certain cases, the classical Gutzeit method is convenient. Methods based on ion-associates of molybdoarsenate with basic dyes are very sensitive.
8.2.1. Arsenomolybdenum blue method Arsenic, oxidised to As(V) (e.g. by evaporation to dryness with HNO3) is made to react in a suitably acid solution (0.1-0.3 M H2SO4) with ammonium molybdate to form the molybdoarsenic heteropoly acid. The molybdoarsenic acid is then reduced [the Mo(VI) atoms linked with As(V) are reduced to a lower oxidation degree] and a blue reaction product, the arsenomolybdenum blue is formed. The absorbance is measured either in the aqueous solution, or after extraction into oxygen-containing organic solvent [29-33]. The reaction conditions are so selected that the unreacted molybdate ions are not reduced. N2H4, SnC12, and ascorbic acid are employed as reducing agents. A mixture containing ammonium molybdate, hydrazine, and H2SO4in suitable proportions, is conveniently used in the determination of As. The best solvents for the extraction of arsenomolybdenum blue are butyl and amyl alcohols, ethers, and ethyl acetate. The molar absorptivity e of the As-Mo blue in butanol solution is 2.5"104 at Xmax=730 nm (a=0.33). Both the e and the ~maxvalues depend on the reducing agent and the extraction solvent used. Alternatively, arsenic may be extracted as molybdoarsenic acid, and the reducing agent may then be added to the organic phase [25]. Phosphorus(V) forms phosphomolybdenum blue under the reaction conditions used to form arsenomolybdenum blue. The corresponding silicon and germanium compounds are
8.2. Methods of determination
101
formed under slightly differing conditions. Conditions for determining As(V), P(V), and Si present together have been given [34].
Reagents Molybdate reagent: a) dissolve 1.0 g of ammonium molybdate in 100 ml of 2 M H2SO4; b) dissolve 0.10 g of hydrazine sulphate in 100 ml of water. Immediately before use, mix 10 ml of solution a) with 10 ml of solution b) and dilute the solution with water to 100 ml. Solutions a) and b) should not be kept for longer than 3-4 days. Standard arsenic(HI) solution: 1 mg/ml. Dissolve 1.3200 g As203 in 20 ml of 2 M NaOH, dilute the solution with a little water, acidify slightly with 2M HC1, and dilute the solution with water in a volumetric flask to 1 1. Arsenic-free conc. hydrochloric acid. To 20 ml of conc. HC1 add 1 drop of 1% KI solution, allow to stand for 5 min, and then shake it with three 5-ml portions of benzene.
Procedure Extractive separation of As. Evaporate a sample, containing not more than 60 ~tg of As, almost to dryness, with HNO3 or H2SO4 (the solution must not contain halide ions). To the cooled solution, add 10 ml of As-free conc. HC1 and 2 drops ofl % KI solution. Mix and allow to solution to stand for 5 min, then transfer it to a separating funnel and shake with three 5-ml portions of benzene. Strip the combined extracts with two 5-ml portions of water.
Determination of As. To the aqueous phase, add 2 ml of conc. HNO3, stir, and evaporate the solution almost to dryness. Add 25 ml of molybdate reagent, stir well, and place the beaker in a boiling water-bath for 10 min. After cooling, transfer the solution to a separating funnel and extract the As-Mo blue with 2 portions (e.g. 10 ml) of butyl alcohol. Make up the blue extract to the mark in a 25-ml standard flask with the solvent, and measure the absorbance at 730 nm, using the solvent as reference.
Note: It is also possible to measure the absorbance of the aqueous solution of As-Mo blue. In this case the cooled coloured solution is transferred to a volumetric flask, and diluted to the mark with the molybdate reagent.
8.2.2. Silver diethyldithiocarbamate method The arsine evolved by nascent hydrogen is absorbed in a pyridine solution of silver diethyldithiocarbamate. The pyridine-soluble product of reaction between AsH3 and AgDDTC is intensely violet, whereas the pyridine Ag-DDTC solution is pale yellow [35-38]. The molar absorptivity of the reaction product e=l.4"104 (a = 0.19) at ~max---- 535 nm, whereas the reagent absorbs at <500 nm. The functions of the reagents used in the reduction of arsenic compounds, such as Zn, HC1, NiCI2, SnC12, and KI are discussed below in connection with the Gutzeit method. Sodium borohydride also has been proposed as the reducing agent [39-42]. Sequential spectrophotometric determination of As(III) and As(V) is possible by using borohydride [40]. Hydrogen sulphide, which interferes in the reaction, is separated from arsine on cotton wool impregnated with lead acetate. During the extraction of AsC13 with inert solvents, Sb remains in the aqueous phase. Under the conditions specified in the procedure below, Sb present in approximately the same amount as As does not interfere. When larger amounts of Sb are present, it is advisable to
102
8. Arsenic
increase the quantity of SnCl2 added. Under these conditions Sb(lII) is reduced to the element, and not to SbH3 [22,36]. A solution of Ag-DDTC in CHC13 containing organic bases: 1-ephedrine [35,43,44], ethanolamine [45], brucine [46], or morpholine has been used as an alternative to the obnoxious pyridine solution.
Reagents Silver diethyldithiocarbamate (Ag-DDTC). Dissolve 1 g of the reagent in 100 ml of pyridine. To facilitate dissolution, the pyridine may be heated to 50-60 ~ after the addition of crystalline Ag-DDTC. Preparation of crystalline Ag-DDTC: Dissolve 1.8 g of AgNO3 in 20 ml of water, and 2.6 g Na-DDTK'3H20 in 20 ml of water. Add the AgNO3 solution slowly, with careful stirring, to the Na-DDTC solution. Filter off the Ag-DDTC precipitate on a sintered-glass crucible, and wash several times with water. Dry the precipitate at 100 ~ to constant weight. (Nearly 2.4 g of product is obtained, yield -~90 % with respect to AgNO3. Standard arsenic(III) solution: 1 mg/ml. Preparation as in p. 8.2.1. Zinc (As-free), granulated. Melt down granulated zinc in a quartz crucible and pour it in a thin jet into a tall beaker filled with water of appropriate purity. Dry the comminuted zinc and store it in a stoppered vessel. Cotton wool impregnated with lead acetate. Preparation as in p. 8.2.3.
Procedure Distillation and determination of As. Place in a 50-ml conical flask the almost neutral sample solution containing not more than 80 gg of As. Dilute to 10 ml with water, and then add successively 5 ml of conc. HC1, 5 ml of 10 % KI solution, 4 drops of 10 % SnC12 solution in 6 M HC1, 2 drops of 10 % NiC12 solution, and 1.5 g of zinc. Close the flask with a head carrying the cotton wool impregnated with Pb(CH3COO)2, and connected to a tube immersed in the receiver, which contains 10 ml of the Ag-DDTC pyridine solution. After 30 min (even though all the zinc may not have dissolved) disconnect the receiver and rinse the delivery tube with pyridine. Dilute the solution with pyridine in a 25-ml volumetric flask, and measure the absorbance at 535 nm, using a blank solution as reference.
8.2.3. Gutzeit method The trace amount of arsenic, contained in the sample solution, is reduced to volatile AsH3 with zinc and HC1. A disk of paper impregnated with mercuric bromide is placed across the flow of arsine and hydrogen evolved. The reaction of AsH3 with HgBr2 gives coloured compounds such as yellow H(HgBr)2As,, brown (HgBr)3As, and black Hg3As2. The resulting coloured spot is compared with a set of standard spots corresponding to known amounts of arsenic. The method is sensitive and permits the estimation of arsenic in the range 0.1-3 ~tg [48-501. The nascent hydrogen is produced in reaction of zinc with HC1 (3-4 M). The zinc used should be free of traces of As, and suitably comminuted to provide high rate of dissolving and liberation of hydrogen. Nickel(H) ions catalyse the zinc dissolution. SnC12 and I- facilitate the reduction of As traces. Since also H2S gives a colour reaction with HgBr2, it must be removed from the AsH3 stream before the contact with the mercuric bromide paper. Hydrogen sulphide is absorbed by cotton wool and paper impregnated with lead acetate. PH3, SbH3, and GeH4 also interfere in
8.2. Methods of determination
103
the determination of arsenic. The only phosphorus compounds which can be reduced to phosphine under the reaction conditions are phosphite and hypophosphite.
Reagents Mercuric bromide papers. Place thin, compact filter paper disks (about 20 mm in diameter) in a freshly prepared 5 % HgBr2 solution in ethanol for 30 min. Lay the papers on a watch-glass to dry in air. The papers may be stored in an amber-glass jar for not longer than a week after preparation. Standard arsenic(III) solution: 1 mg/ml. Preparation as in p. 8.2.1. Filter paper and cotton wool impregnated with lead acetate. Impregnate filter paper strips (2.5 x 4 cm) for 30 min in a 10 % lead acetate solution, dry at 105 ~ and pleat into narrow folds. Soak and dry the cotton wool in the same way.
6 5
2 3 z
1
Fig. 8.1. Gutzeit apparatus Gutzeit apparatus (Fig. 8.1): a 50-ml amber-glass bottle fitted with a rubber stopper (2) which carries a glass tube (3), 6-7 mm in inner diameter. The tube has a side hole (4) preventing closure of the passage by liquid drops carried by the gas. A neck above the stopper holds the folded filter paper (5) impregnated with lead acetate. Above the paper is placed cotton wool (6) impregnated with lead acetate. The paper disk impregnated with HgBr2 is sandwiched between evenly cut tube ends held tightly together by a pair of rubber stoppers fitted with projecting glass hooks for clamping by means of rubber bands. Zinc (As-free). Comminution method as in p. 8.2.2.
Procedure Place the sample solution containing 0.2-3 ~tg As in the bottle of the apparatus, and dilute to 10 ml with water. Add 10 ml of HC1 (1 + 1), then 5 ml of 10 % KI solution, 4 drops of 10 % SnC12 solution in 6 M HC1, and 2 drops of 10 % NiC12 solution, and stir well. Then add 1.5 g of comminuted zinc and immediately close the bottle with a head containing the fresh disc of HgBr2 paper. When the evolution of hydrogen is complete (30-60 min), remove the paper disk with the coloured spot from the apparatus. Compare the colour of the spot with a set of standards prepared at the same time and corresponding to 0, 0.5, 1, 2, and 3 ~tg of As. The zero standard is a blank test to allow for any arsenic in the reagents.
104
8. Arsenic
8.2.4. Other methods Sensitive methods for determining arsenic are based on ion-associates formed by molybdoarsenate and basic dyes. Flotation-spectrophotometric methods with the use of Crystal Violet (mixture of cyclohexane and toluene as flotation solvent, e=3.2" 105) [51] and Malachite Green (flotation with diethyl ether, ~=3.2" 105) [52] have been proposed. The ionassociate with Ethyl Violet is extracted with a mixture of cyclohexane and 4-methylpentanone (1+3) (~=2.8"105) [53]. Methods based on extractable associates of the reduced form of molybdoarsenic acid with Crystal Violet (~=3.1" 105), Methyl Violet, Brilliant Green, or Malachite Green have also been applied [54]. The iodide complex of As(HI) associated with Brilliant Green or Butylrhodamine B was filtered off and dissolved in ethanol (~=1.3"105) [55]. A complex of As(HI) with 4nitropyrocatechol forms an extractable ion-pair with Brilliant Green. The amplification method for arsenic is based on its extractive separation as molybdoarsenic acid and determination of Mo with Sulphonitrophenol S (e = 4.5" 105) or zinc dithiol [56]. The molybdoarsenic acid, after extraction into a mixture of butyl acetate and ethanol, is decomposed, then Mo(VI) is reduced to Mo(III) in a Jones reducer, and finally Mo is oxidised to Mo(VI) be means of Fe(HI). The Fe(II) produced in this reaction gives a coloured complex with ferrozine. The amplification factor is 36, and e=9.4" 105 [57]. In the reaction of As(HI) with IO3-, an equivalent amount of iodine is liberated; the absorbance of the violet solution in CC14 is measured [58]. In another indirect method, arsine reduces (in the presence of Ag + ions) Fe(III) to Fe(II) which gives a coloured complex with ferrozine [59].
8.3. Analytical applications The arsenomolybdenum blue method was applied for determination of arsenic in: biological materials [7,17,60,61], plants [24], water [24,62-64], silicates [20], petroleum products, organic compounds [24,65], steel [15,66], antimony [2,3,67,68], antimony and gallium chlorides [69], bismuth [18], zinc [70], zinc and lead concentrates [71], tungsten [72], copper alloys [73], gold and platinum [34], silicon [74], selenium [75], and boron [76]. Trace amounts of As were determined in water and sewage by the following method: The sample was treated with sodium tetraborate (NaBH4). The AsH3 formed was absorbed with a solution of iodine, and the resulting As(V) was determined by the As-Mo blue method [77]. The Ag-DDTC method was used for determination of arsenic in: waters [42,47,78-80], plant materials [41,48], food products [82], sewage and sediments [83], iron ores [44], cast iron and steel [45,84], copper and its salts [22,45], silver and gold [85], high purity reagents [21,46], germanium dioxide [86], hydrofluoric acid [87], phosphorus compounds [88], and sulphur 89]. The Gutzeit method was applied in determinations of arsenic i.a. in: germanium and its compounds [49], silicon [49,50], and petroleum products [48]. Arsenic was also determined in natural water after flotation of the ion-associate with Malachite Green [52], and Crystal Violet [90], and after extraction with Methylene Blue [91].
References 1. Beard H.C., Lyerly L.A., Anal Chem., 33, 1781 (1961). 2. Chwastowska J., Podg6rny W., Chem. Anal. (Warsaw), 20, 53 (1975).
References 3. Saulnier J., Bauer D., Rosset R., Analusis, 7, 242 (1979). 4. Marin L., Vernet M.,Analusis, 7, 33 (1979). 5. Suzuki N., Satoh K., Shoji H., Imura H., Anal. Chim. Acta, 185, 239 (1986). 6. Palanivelu K., Balasubramanian N., Ramakrishna T.V., Talanta, 39, 555 (1992). 7. Puttemans F., Van den Wilken P., Massart D.L., Anal. Chim. Acta, 149, 123 (1983). 8. Amankwah S.A., Fasching J.L., Talanta, 32, 111 (1985). 9. Mok W.M., Wai C.M., Talanta, 35, 183 (1988). 10. Hayashi K. et al., Anal. Sci., 2, 347 (1986). 11. Wfinsch G., Umland F., Z. Anal. Chem., 247, 287 (1969). 12. Ivanov N.A., Todorova N.G.,Anal. Chim. Acta, 91,389 (1977). 13. Jaz M.E., Siddique E., Ahmed A., Talanta, 32, 1055 (1985). 14. Shkinev V.M. et al., Zh. Anal. Khim., 33, 922 (1978). 15. Shkinev V.M. et al., Zavod. Lab., 47, No 10, 11 (1981). 16. Shkinev V.M. et al.,Anal. Chim. Acta, 167, 145 (1985). 17. Dyfverman A., Bonnichsen R., Anal. Chim. Acta, 23, 491 (1960). 18. Jackwerth E., Z. Anal. Chem., 211,254 (1965). 19. Analytical Methods Committee, Analyst, 100, 54 (1975). 20. Sala J.V., Hernandis V., Canals A., Analyst, 111,965 (1987). 21. Marczenko Z., Mojski M., Chem. Anal. (Warsaw), 14, 495 (1969). 22. Meyer J., Z. Anal. Chem., 210, 84 (1965). 23. Reay P.F., Anal. Chim. Acta, 72, 145 (1974). 24. Briska M., Hoffmeister W., Z. Anal. Chem., 268, 347 (1974). 25. Portmann J.E., Riley J.P., Anal. Chim. Acta, 31,509 (1964). 26. Terada K., Matsumoto K., Inaba T., Anal. Chim. Acta, 158, 207 (1984). 27. Ficklin W.H., Talanta, 30, 371 (1983). 27a. Abrazheev R.V., Zorin A.D., Zh. Anal. Khim., 54, 1253 (1999). 28. Narusawa Y., Anal. Chim. Acta, 204, 53 (1988). 29. Pakalns P.,Anal. Chim. Acta, 47, 225 (1969). 30. Morosanova S.A., Zh. Anal. Khim., 29, 529, 1108 (1974). 31. Shida J. et al., Bull. Chem. Soc. Jpn., 56, 633 (1983). 32. Bogdanova V.I., Mikrochim. Acta, 1984 II, 317. 33. Kunze S., Dietze U., Ackermann G., Mikrochim. Acta, 1989 III, 147. 34. Marczenko Z., Lenarczyk _., Chem. Anal. (Warsaw), 19, 679 (1974). 35. Bode H., Hachmann K., Z. Anal. Chem., 229, 261 (1967); 241, 18 (1968). 36. Dubois L. et al., Mikrochim. Acta, 1966, 415; 1969, 185. 37. Gastinger E., Mikrochim. Acta, 1972, 526. 38. Budesinsky B.W., Microchem. J., 24, 80 (1979). 39. Basadre-Pampin M. et al., Microchem. J., 23, 360 (1978). 40. Howard A.G., Arbab-Zavar M.H., Analyst, 105, 338 (1980). 41. Merry R.H., Zarcinas B.A., Analyst, 105, 558 (1980). 42. Dodoo D.K., Vrchlabsky M., Chem. Anal. (Warsaw), 26, 867 (1981). 43. Kopp J.F.,Anal. Chem., 45, 1786 (1973). 44. Bhargava O.P., Gmitro M., Hines W.G., Talanta, 27, 263 (1980). 45. Hulanicki A., G__b S., Chem. Anal. (Warsaw), 15, 1089 (1970). 46. Ackermann G., K6the J., Z. Anal. Chem., 323, 135 (1986). 47. Gupta P.K., Prabhat K. Gupta, Microchem. J., 33, 243 (1986). 48. Maranowski N.C., Snyder R.E., Clark R.O.,Anal. Chem., 29, 353 (1957). 49. Tumanov A.A., Sidorenko A.N., Taradenkova F.S., Zavod. Lab., 30, 652 (1964). 50. Rigin V.I., Mel'nichenko N.N., Zavod. Lab., 32, 394 (1966). 51. Babko A.K., Ivashkovich E.M., Zh. Anal. Khim., 27, 120 (1972).
105
106
8. Arsenic
52. Nasu T., Kan M., Analyst, 113, 1683 (1988). 53. Motomizu S., Wakimoto T., T6ei K., Analyst, 108, 944 (1983). 54. Ganago L.I., Ishchenko N.N., Zh. Anal. Khim., 34, 1768 (1979). 55. Nazarenko V.A. et al., Zh. Anal. Khim., 37, 1652 (1982). 56. Malyutina T.M., Savvin S.B. et al., Zh. Anal. Khim., 29, 925 (1974). 57. Pichaj M.A., Bet-Pera F., Mikrochim. Acta, 1986 I, 429. 58. Sandhu S.S., Analyst, 101, 856 (1976). 59. Kellen G.J., Jaselskis B.,Anal. Chem., 48, 1538 (1976). 60. Eichhorn G., Wolf W., Berger S.A., Mikrochim. Acta, 1976 I, 135. 61. Maher W.A., Analyst, 108, 939 (1983). 62. Johnson D.L., Pilson M.E., Anal. Chim. Acta, 58, 289 (1972). 63. Stauffer R.E.,Anal. Chem., 55, 1205 (1983). 64. Frenzel W., Titzenthaler F., Elbel S., Talanta, 41, 1965 (1994). 65. Campbell A.D., Low Choong-Pak, Mikrochim. Acta, 1980 I, 139. 66. Fogg A.G., Marriott D.R., Burns D.T., Analyst, 97, 657 (1972). 67. Marczenko Z., Mojski M., Skibe H., Chem. Anal. (Warsaw), 17, 881 (1972). 68. Mogileva M.G., Kozlova E.L., Zavod. Lab., 51, No 7, 7 (1985). 69. Goryushina V.G., Romanova E.V., Razumova L.C., Zh. Anal. Khim., 28, 601 (1973). 70. Raghavan R., Murthy S.S., Rao C.S., Talanta, 36, 951 (1989). 71. Rao V.S., Rajan S.C., Roa N.V., Talanta, 40, 653 (1993). 72. Orlova V.A. et al., Zh. Anal. Khim., 32, 1591 (1977). 73. Scholes I.R., Waterman W.R.,Analyst, 88, 374 (1963). 74. Buldini P.L., Zini Q., Ferri D., Mikrochim. Acta, 1983 II, 131. 75. Ebner E., Z. Anal. Chem., 206, 106 (1964). 76. Marczenko Z., Chem. Anal. (Warsaw), 9, 1093 (1964). 77. Haywood M.G., Riley J.P.,Anal. Chim. Acta, 85, 219 (1976). 78. Sandhu S.S., Nelson P., Anal. Chem., 50, 322 (1978). 79. Tamari Y., Yamamoto N., Tsuji H., Kusaka Y., Anal. Sci., 5, 481 (1989). 80. Chatterjee A. et al.,Analyst, 120, 643 (1995). 81. Miliadis G.E., Liapis K.S.,Anal. Chim. Acta, 283, 258 (1993). 82. Kaliszewski J., Teperek J., Chem. Anal. (Warsaw), 32, 757 (1987). 83. Lopez A., Torralba R., Palacios H.A., C~imara C., Talanta, 39, 1343 (1992). 84. Bhargava O.P., Donovan J.F., Hines W.G., Anal. Chem., 44, 2402 (1972). 85. Tayurskii V.A. et al., Zavod. Lab., 47, 18 (1981). 86. Fowler E.W., Analyst, 88, 380 (1963). 87. Meyer J., Z. Anal. Chem., 229, 409 (1967). 88. Nowicka J., Chem. Anal. (Warsaw), 39, 741 (1994). 89. Steinke J., Z. Anal. Chem., 240, 184 (1968). 90. Kunze S., Dietze U., Acta Hydrochim. Hydrobiol., 19, 17 (1991). 91. Pal T., Jana N.R., Sau T., Anal. Proc., 32, 369 (1995).
Chapter 9. Beryllium Beryllium (Be, at. mass 9.012) forms cations Be 2+. In its chemical properties, beryllium resembles magnesium and aluminium. Beryllium hydroxide is precipitated at pH --6, and dissolves in alkali hydroxides. Freshly precipitated Be(OH)2 dissolves in NazCO3 solution to form a rather unstable carbonate complex. Beryllium also forms weak complexes with citrate, tartrate, and fluoride anions. Beryllium and its compounds are highly toxic.
9.1. Methods of separation and preconcentration 9.1.1. Precipitation. Extraction Precipitation of Be(OH)2 with ammonia at pH --8, with A1 and Fe(III) as collectors, enables beryllium to be separated from Ca, Mg, Mn, and Cr [after oxidation of Cr(lII) to Cr(VI). In the presence of EDTA, the only Analytical Group III metals which ammonia precipitates are Be, Ti, U, Nb, and Ta. When the sample containing Be is fused with NaOH in a nickel crucible, and the cooled melt leached with water, beryllium remains in solution, while the insoluble residue contains Fe, Mn, Ni, Mg, Ti, and some other metal hydroxides. Traces of beryllium have been coprecipitated with Sn(OH)4 as collector, in the presence of EDTA at pH --13 [1 ]. Extraction with acetylacetone in CHC13, CC14 or C6H6 enables to separate Be from Mg, Ca, and phosphate. In the presence of EDTA Fe(III) and A1 remain in the aqueous phase; traces of Fe(III) and A1 are, however, also extracted. The beryllium can be back-extracted into hydrochloric acid (--5 M) [2-4]. Trifluoroacetylacetone and hexafluoroacetylacetone have also been used to extract beryllium [5]. Beryllium may be separated by extraction with benzohydroxamic acid and some of its derivatives (including heterocyclic ones [6]), in cyclohexanone [7] and with Aliquat 336S in xylene from malonic acid solution (pH 5-7) [8,9]. Beryllium has also been extracted from thiocyanate media with TBP in toluene [10] and TOA in MIBK [11].
9.1.2. Ion exchangers and other sorbents The oxalate solution at pH 4.4 is passed through a strongly acidic cation exchanger; Fe(III) and A1 complexes are eluted. The beryllium, which is retained on the column, is then eluted with 10 % HC1. By a similar procedure Be is separated from other cations with the use of EDTA in a weakly acid solution (pH 4) [12]. The separation of beryllium from a number of cations by using cation exchangers has been achieved by consecutive elution of the metals with increasing acid concentrations. Beryllium has been separated from various metal ions by cation exchange in the systems thiocyanate-DMSO [13] and HNO3-methanol [14]. Beryllium has been separated on an anion exchanger from large quantities of uranium, by using a mixture of 5 M HNO3 and methanol. Beryllium was also separated from Fe(III) and A1 on an anion-exchanger, using a fluoride medium [15].
108
9. Beryllium
A thiocyanate medium was applied in separating Be on a silica gel column impregnated with TBP. Beryllium was eluted with 0.1 M HC1 [16]. The same sorbent impregnated with HDEHP was used for selective pre-concentration of Be and for isolation of this element from a number of other metals [ 17].
9.2. Methods of determination Triphenylmethane and azo reagents are used in most methods for determining beryllium. Methods using Chrome Azurol S or Eriochrome Cyanine R and some cationic surfactants are very sensitive. The selectivity of methods for beryllium determination is improved by the use of EDTA as masking agent.
9.2.1. Chrome Azurol S method Chrome Azurol S (CAS, formula 4.18) forms a coloured chelate complex with Be 2+, and this has been used for the determination of Be [ 18-21 ]. In acetate (or hexamine) buffer and in the presence of EDTA as masking agent, the Chrome Azurol S method is highly selective for beryllium. The absorbance of the complex depends on the pH, and on the concentrations of CAS, EDTA, and the acetate buffer. The absorbance increases with increasing CAS concentration, and decreases with increasing EDTA and acetate concentrations. A pH o f - 5 is the most suitable. Below this pH, the absorbance of CAS increases considerably, and above it the absorbance of the beryllium complex is decreased more by EDTA. Because of this, it is difficult to give a definitive value for the molar absorptivity of the complex. The absorption maximum of the complex, (vs. the reagent solution as reference), is at --570 nm. At this wavelength, and under the reaction conditions given in the procedure below, the molar absorptivity e is 1.510 4 (a - - 1.67). In the absence of EDTA, the e value increases to 2.4104. EDTA successfully masks Cd, Co, Cu, Fe(III), Mn, Mo, Pb, V(IV), and Zn. Copper (2 mg), causes a positive error of 2% . Ascorbic acid reduces Fe(III) to Fe(II), and V(V) to V(IV). The EDTA complexes of A1 and Cr(III) are formed slowly, and it is necessary to heat the solution after the addition of EDTA. Aluminium can be masked with oxine. Zirconium interferes in the determination even in the presence of EDTA, but can be masked by adding tartaric acid. Interfering agents are: U, Th, and Ti, as well as fluoride and, to a lesser degree, phosphate. It has been found that the presence of 2,2'-bipyridyl enhances the sensitivity of the method (e = 5.4104) [22].
Reagents Chrome Azurol S (CAS): 0.1% solution. Dissolve 100 mg of the reagent in water and dilute to 100 ml in a volumetric flask. Standard beryllium solution: 1 mg/ml. Dissolve 1.9640 g of BeSO4.H20 in water containing 1 ml of conc. HC1, and dilute the solution with water to volume in a 100-ml standard flask Hexamine buffer: pH 5.0. To 250 ml of 10% hexamine solution add 45 ml of 2M HC1. The buffer is not very stable.
9.2. Methods of determination
109
Procedure To the slightly acidic solution (10-15 ml) containing not more than 12 gg of Be, add -- 10 mg of ascorbic acid and 1 ml of 5% EDTA solution. After 5 min, add 2.5 ml of CAS solution, --0.1M NaOH solution to adjust the pH to --5, and 5 ml of the buffer. Dilute with water to 25 ml in the standard flask, mix well, and after 10 min measure the absorbance of the solution at 570 nm, v s . a blank solution as reference.
9.2.2. Chrome Azurol S-surfactant method In the presence of a cationic surfactant, such as CTA, CP or Zephiramine, the reaction of Be 2+ ions with Chrome Azurol (CAS) is several times more sensitive [23-25]. Maximal and stable absorbance of the triple complex is obtained with a large excess of surfactant in relation to CAS. In these systems, ternary complexes are formed in which the ratio CAS:Be is greater than in binary systems (without surfactant). Figure 9.1 shows the absorption spectra of Chrome Azurol S and the binary and ternary (with CTA) complexes of beryllium 3
1
,~00
500
600
wavelengtli, nm
700
Fig. 9.1. Absorption spectra of Chrome Azurol S (CAS) (1), its Be complex (2), and the ternary complex Be-CAS-CTA (3) (pH 5) Under the conditions given below the value of e is 9.45104 (a - 14.8) at 615 nm [24]. The molar absorptivity is higher (e = 1.0 105) in the absence of EDTA, but, as in the binary system, the use of EDTA is necessary to increase the selectivity of the method. The optimum pH value is --5; it is advisable to use hexamine buffer. At room temperature the reaction is slow; measurements of the absorbance should be made after--1 h. Besides CTA [23,26], other cationic surfactants have been proposed, namely: CP [24,27], Zephiramine ( e - 1.1105)[23,25], polyoxyethylenedecylamine [28], and Sterinol (dimethyl-laurylbenzylammonium bromide) ( e - 1.06105) [29].
Reagents Chrome Azurol S (CAS): 1.10 -3 M ( --0.05% ) solution. Cetyltrimethylammonium chloride (or bromide) (CTA): 5.10 -3 M (-~0.15%) solution. Standard beryllium solution, preparation as in Section 9.2.1. Hexamine buffer, preparation as in Section 9.2.1.
110
9. Beryllium
Procedure To the acidic solution (10-15 ml, pH 1-2) containing not more than 2 ~tg of Be, add 3 mg of ascorbic acid, and 1 ml of 1% EDTA solution. After 5 min, add 3 ml of CAS solution and 2.5 ml of CTA solution. Adjust the pH to -~5 with 0.1M NaOH solution and add 2.5 ml of buffer. Dilute to 25 ml in a standard flask, mix well, and after 1 h measure the absorbance of the solution at 615 nm v s . a blank solution.
9.2.3 Other methods Erioehrome Cyanine R (ECR) (formula 4.17) reacts with beryllium ions [4,9,10,16,30] similarly to Chrome Azurol S (see Section 9.2.1). At pH 9.7, ~maxof ECR is 435 nm and that of its water-soluble beryllium complex is 525 nm. The molar absorptivity of the complex is 1 . 5 1 0 4. EDTA, tartrate and cyanide are used as the main masking agents for interfering metals. In the presence of cationic surfactants, the sensitivity is increased several times, and significant bathochromic shifts are observed. In the case of CTA, e = 8.7.10 4 at 590 nm (pH -~7) [31,32]. Beryllium was also sorbed on anion exchange resins impregnated with ECR [33]. Triphenylmethane chelating reagents, other than CAS and ECR, have also been used to determine beryllium, e.g. Aluminon [34,35], Xylenol Orange [36], Brilliant Violet B [2],, and Chromal Blue G (e = 3.1.104) [37]. A considerable increase of sensitivity is obtained by using Chromal Blue G in the presence of CTA (e = 9.4.104 at 626 nm) [38]. A large number of spectrophotometric methods for determining beryllium are based on azo reagents. Beryllon II (formula 9.1) forms a blue complex with beryllium at pH 12-13 [7,30,39,40]; the molar absorptivity e = 1.2.104 at 630 nm.
H03~
OH
OH OH (9.1)
Beryllon I, Beryllon III [41,42], and Beryllon IV [43] have not been widely applied. Other azo reagents used for determining Be are: Thoron I (e = 1.4.104 at 523 nm [8,44,45], Chlorophosphonazo R [17,46}, Eriochrome Black T (extraction with TOA in CHC13, e = 5.5-10 4) [47], Calcichrome [48], and Sulphochlorophenol S (in acetic acid and propanol medium) [49]. In other methods for determination of beryllium use is made of such organic reagents, as 2-phenoxyquinalizarin-3,4'-disulphonic acid [12], 1-hydroxy-2-carboxyanthraquinone (the first-derivative spectrum is used) [50], 8-hydroxyquinaldine (e = 3.5.103) [51], and carminic acid [52]. In an indirect method of determining beryllium a Ti(IV)-HzOz-HF reagent is added to a sample solution containing beryllium. As a result of the reaction of fluoride with beryllium, an equivalent amount of yellow peroxotitanium(IV) complex is formed [53].
References
111
9.3. Analytical applications The Chrome Azurol S method has been applied for determining beryllium in, for example, bronzes [54] and water [55]. In the presence of a surfactant, beryllium was determined in minerals [15], sewage [56], coal dust [57,58], and aluminium alloys [59]. Eriochrome Cyanine R was applied in determination of beryllium in water [33] and in silicates [4]. Aluminon has been used for determining beryllium in airborne dust [34]. Methods involving Beryllon II were used for determining beryllium in minerals [15] and in natural waters [60].
References 1. Plotnikov V.I., Safonov I.I., Zh. Anal. Khim., 33, 2350 (1978). 2. Uesugi K., Anal. Chim. Acta, 49, 89 (1970). 3. Merrill J.R., Honda M., Arnold J.R., Anal. Chem., 32, 1420 (1960). 4. Sauerer A., Troll G., Talanta, 31,249 (1984). 5. Scribner W.G., Borchers M.J., Treat W.J., Anal. Chem., 38, 1779 (1966). 6. Agraval Y.K., Dallali H., Microchem. J., 43, 258 (1991). 7. Borzenkova N.P., Burmistrova L.A., Zh. Anal. Khim., 27, 682 (1972). 8. Rao R.R., Khopkar S.M.,Anal. Chem., 55, 2320 (1983). 9. Narayanan P., Khopkar S.M.,Analyst, 110, 1295 (1985). 10. Kalyanaraman S., Khophar S.M., Anal. Chem., 47, 2041 (1975). 11. Castillo J.R. et al., Talanta, 29, 485 (1982). 12. Owens E.G., Yoe J.H.,Anal. Chem., 32, 1345 (1960); Talanta, 8, 505 (1961). 13. Janauer G.E., Madrid E.O., Mikrochim. Acta, 1974, 769. 14. Strelow F.W., Weinert C.H.,Anal. Chim. Acta, 83, 179 (1976). 15. Eristavi V.D., Eristavi D.I., Brouchek F.I., Zh. Anal. Khim., 23, 782 (1968). 16. Sharma C., Khopkar S.M., Anal. Chim. Acta, 167, 403 (1985). 17. Bykhovtsova I.V. et al., Zh. Anal. Khim., 40, 814 (1985). 18. Pakalns P., Anal. Chim. Acta, 31,576 (1964). 19. Sommer L., Kubafi V., Coll. Czech. Chem. Comm., 32, 4355 (1967). 20. Sommer L., Kubafi V.,Anal. Chim. Acta, 44, 333 (1969). 21. Petrova T.V., Sokolovskaya L.A., Savvin S.B., Zh. Anal. Khim., 38, 646 (1983). 22. Buhl F., Kwapulifiska G., Mikrochim. Acta, 1980 I, 89. 23. Marczenko Z., Ka~owska H., Chem. Anal. (Warsaw), 22, 935 (1977). 24. Rudometkina T.F., Chernova I.B., Orlov V.V., Zavod. Lab., 54, No 9, 5 (1988). 25. Jarosz M., Biernat I., Chem. Anal. (Warsaw), 33, 693 (1988). 26. Callahan J.H., Cook K.D., Anal. Chem., 54, 59 (1982). 27. Mulwani H.R., Sathe R.M.,Analyst, 102, 137 (1977) 28. Nishida H., Nishida T., Ohtomo H., Bull. Chem. Soc. Jpn., 49, 571 (1976). 29. Kwapulifiska G., Buhl F., Mikrochim. Acta, 1984 I, 333. 30. Kasiura K., Chem. Anal. (Warsaw), 16, 407 (1971). 31. Marczenko Z., Ka~owska H., Microchem. J., 23, 71 (1978). 32. Tikhonov V.N., Vashurkina E.A., Zh. Anal. Khim., 33, 1298 (1978). 33. Valencia M.C., Boudra S., Bosque-Sendra J.M., Analyst, 118, 1333 (1993); Anal. Chim. Acta, 327, 73 (1996). 34. McCloskey J.P., Microchem. J., 12, 32, 41 (1967).
112
9. Beryllium
35. Dhond P.V., Khopkar S.M., Anal. Chem., 45, 1937 (1973). 36. Otomo M., Bull. Chem. Soc. Jpn., 38, 730 (1965). 37. Uesugi K., Bull. Chem. Soc. Jpn., 42, 2998 (1969). 38. Uesugi K., Miyawaki M., Microchem. J., 21,438 (1976). 39. Adamovich L.P., Mirnaya A.P., Zh. Anal. Khim., 18, 292 (1963). 40. Xu Y.J., Chen X.G., Hu Z.D., Talanta, 40, 883 (1993). 41. Pakalns P., Flynn W.W., Analyst, 90, 300 (1965). 42. Zhu Y., Shao J.,Analyst, 114, 97 (1989). 43. Budanova L.M., Pinaeva S.N., Zavod. Lab., 32, 401 (1966). 44. Einaga H., Ishii H., Anal. Chim. Acta, 54, 113 (1971). 45. Keil R., Z. Anal. Chem., 262, 273 (1972). 46. Lukyanov V.F. et al., Zh. Anal. Khim., 18, 562 (1963). 47. Pyatnitskii I.V., Pinaeva S.G., Pospelova N.V., Zh. Anal. Khim., 30, 2316 (1975). 48. Einaga H., Ishii H., Talanta, 28, 799 (1981). 49. Petrova T.V. et al., Zh. Anal. Khim., 36, 90 (1981). 50. Salinas F., de la Pena A.M., Murillo J.A., Analyst, 112, 1391 (1987). 51. Keil R., Mikrochim. Acta, 1973, 919. 52. Kaur P., Gupta V.K., Z. Anal. Chem., 334, 447 (1989). 53. Matsubara C., Takamura K., Anal. Chim. Acta, 77, 255 (1975). 54. Egkinja I., Grabari_ Z., Grabari_ B.S., Mikrochim. Acta, 1985 II, 443. 55. Dong H., Jiang M., Zhao G., Wang M.,Anal. Sci., 7, 69 (1991). 56. Qiu X., Zhu T., Chen J., Fresenius'J. Anal. Chem., 342, 172 (1992). 57. Nishida H.,Anal. Sci., 7, 975 (1991). 58. Buhl F., Kwapulifiska G., Chem. Anal. (Warsaw), 33, 513 (1988). 59. Rudometkina T.F., Chernova I.B., Orlov V.V., Zavod. Lab., 54, No 9, 5 (1988). 60. Kornienko T.G., Samchuk A.I., Ukr. Khim. Zh., 38, 917 (1972).
Chapter 10. Bismuth Bismuth (Bi, at. mass 208.98) occurs in its compounds in the III and V oxidation states. Bismuthate, containing Bi(V) exists only in solids (e.g., NaBiO3). Upon dissolution, only compounds of Bi(III) are found. Bismuth(m) hydrolyses at pH 1-2, and shows no amphoteric properties. Bismuth([II) forms citrate-, oxalate-, iodide-, thiosulphate-, and EDTA complexes.
10.1. Methods of separation and preconcentration 10.1.1. Extraction. Precipitation Extraction of bismuth with dithizone in CHC13 or CC14, in the presence of masking agents, is a selective method for separating traces of Bi. It is often connected with the determination of Bi as dithizonate (see below). The extraction of bismuth diethyldithiocarbamate into CC14 or CHC13, from alkaline solution containing tartrate, cyanide, and EDTA, is a specific method for separation of Bi. After the extraction Bi can be determined either directly as the coloured complex Bi(DDTC)3 (see below), or by other methods [ 1,2]. Bismuth can be extracted from strongly acid solutions (-2 M H2SO4 or HC104) as the iodide complex, with a mixture of isoamyl acetate and isoamyl alcohol [3]. The anionic iodide complex of Bi was associated with a cationic complex of K + with the macrocyclic polyether dibenzo-18-crown-6, and the resulting ion-associate was extracted into a (1+3) mixture of CHC13 with 1,2-dichloroethane [4]. When precipitated as the sulphide from the 2 M HC1 with Cu(II) as the collector bismuth is separated from Pb, Sn, and Cd. When the precipitation is carried out in 0.2-0.3 M HC1, other metals of the Analytical Group I and II are precipitated along with Bi. When traces of Bi are precipitated as the hydroxide with ammonia, Fe(III), A1, and La [5] can be used as collectors. From a HNO3 solution of pH 1-2.5, traces of Bi can be separated with a MnO2 aq. Collector, which is precipitated in reaction of Mn 2+ with MNO4[6]. Sb and Sn are precipitated along with Bi. To determine Bi203 (-0.01%) in bismuth, the metal is dissolved in mercury, and the undissolved oxide is separated by flotation [7]. A co-precipitate of traces of bismuth with Fe(OH)3 (pH 4) is separated by flotation with the use of a surfactant [8].
10.1.2. Ion exchange Strongly basic anion exchangers retain Bi from dilute HC1 solutions (0.1-1 M), allowing for separation of Bi from Fe(III) and other metals [9]. Bismuth is eluted from the column with thiourea in dilute H2SO4, with dilute HNO3, or with a mixture of HBr and HNO3 [ 10]. Bismuth has been separated from other metals, retained on a cation exchange column, by elution with HBr [11]. From dilute HC1 solutions cation exchangers retain Bi and other metal cations, whereas Pt is not sorbed [12]. Successive elutions with 0.3 M and 0.6 M HNO3 enables the separation ofT1 and Ag from Bi [13].
114
10. Bismuth
10.2. Methods of determination Trace amounts of Bi are determined conveniently by the dithizone method. The Xylenol Orange method is less sensitive. The diethyldithiocarbamate method is not very sensitive, but it is specific for Bi. A review of bismuth determination methods has been published [14].
10.2.1 Dithizone method With dithizone (formula 1.1), bismuth(l/I) ions form an orange-brown complex, Bi(HDz)3, which is soluble in CC14 and CHC13, and is stable over the pH range 3-9.5. This dithizonate is the basis of the spectrophotometric method [15,16]. At )~max= 490 nm, e = 7.49.104 (a = 0.38). The absorption spectrum of Bi dithizonate is shown in Fig. 4.4. When cyanide and tartrate are present as masking agents, only Pb, TI(I), and Sn(I1) dithizonates are co-extracted with bismuth from slightly alkaline medium (pH 8-9.5). Tin(IV) does not react with dithizone. Lead and thallium can be separated from bismuth since their dithizonates are unstable in slightly acidic medium (pH 3.0-3.5). After Bi, Pb, and T1 have been extracted into CC14, the lead and thallium are stripped into an aqueous solution at pH 3.3. If the sample solution contains considerably more lead than bismuth, it is more convenient to prevent the extraction of lead. In this case, the noble metals (Pt, Pd, Au, Ag, and Hg) and the copper in the sample are quantitatively extracted with dithizone at pH 0.51.0, after which the pH of the aqueous solution is readjusted to 3.1, and the bismuth is then extracted with dithizone. If the amounts of Zn, Cd, and Pb in the aqueous solution considerably exceed that of bismuth, then traces of Zn, Cd, and Pb dithizonates are also extracted. The cadmium and lead are quantitatively removed by stripping with an aqueous solution at pH 3.3. Zinc dithizonate, however, is not decomposed at pH 3.3, and below this pH bismuth dithizonate is partly decomposed. The traces of zinc are stripped from the extract with dilute (-~0.05%) KCN solution buffered at pH 9.5. An unbuffered KCN solution is sufficiently alkaline to partly decompose Bi(HDz). At higher concentrations, halide ions inhibit the extraction of bismuth from acid medium. The effect is most severe with iodide.
Reagents Dithizone (H2Dz)" 0.001% solution in CC14. Preparation as in Section 47.2.1. Standard bismuth solution: lmg/ml. Dissolve 2.3210 g of Bi(NO3)3.5H20 in 100 HNO3 (1 +3), and dilute the solution to volume with water, in a 1-1itre standard Working solutions are obtained by diluting the stock solution with 0.01M HNO3. Potassium cyanide: 10% solution. Preparation as in Section 27.2.1. Wash solution (pH 3.3+0.1). Adjust an approximately 0.1% NH4C1 solution with HC1 to pH 3.3+_0.1. Buffer solution (pH 9.5). Dissolve 60 g of NH4C1 in water, add 120 ml of ammonia and dilute with water to 1 litre.
ml of flask.
dilute conc.
10.2. Methods of determination
115
Procedure Any Cu, Ag, Au, Pt, Pd, or Hg present in the sample should be removed by extraction with dithizone at pH 0.5-1.0. Adjust the pH of the sample solution, containing not more than 40 ~tg of Bi, with ammonia to pH 3.1+0.1. Extract Bi with several aliquots of the dithizone solution in CC14 (1 ml of 0.001% HzDz solution is equivalent to 2.7 ~tg of B i ) . Wash the combined extracts by shaking successively with the wash solution, water, and then with a solution containing 3 drops of the buffer solution (pH 9.5) and 3 drops of 10% KCN solution per 10 ml of water. Finally wash the extract with water, and dilute to volume in a 25-ml or smaller standard flask with CC14. Measure the absorbance of the extract at 490 nm, using the solvent or a blank solution as reference.
Notes. 1. If other metals (e.g., Zn, Pb, and Cd) are to be determined in the aqueous solution after extraction of Bi, add a few drops of conc. HC1 and H202 to the combined aqueous washings, evaporate the solution to 3 4 ml, and combine the residue with the aqueous solution from which bismuth was extracted. 2. Both Bi and Pb dithizonates are extracted from cyanide solution. To remove the lead, shake the extract with two portions of the pH 3.3 wash solution, and then with the pH 9.5 buffer solution to remove the free dithizone liberated by the decomposition of Pb(HDz)2. 3. Before extracting bismuth and lead from ammoniacal cyanide solution add purified potassium sodium tartrate (see Section 27.2.1) to the initial acidic solution to prevent precipitation of hydrolyzable metals. 10.2.2. D i e t h y l d i t h i o c a r b a m a t e m e t h o d Bismuth forms a chelate (soluble, at pH 4-11, in CC14 and iso-amyl alcohol) with sodium diethyldithiocarbamate (formula 4.40). The absorption maximum of Bi(DDTC)3 in CC14 solution (absorption spectrum see Fig. 19.1) is at 370 nm, ~ - 8.6.103. At 400 nm, e = 6.7-103, a = 0.033. The method of determining bismuth as the yellow Bi(DDTC)3 complex, although not very sensitive, is valuable as being specific for Bi. Bismuth is the only metal forming a coloured complex with DDTC, in ammonia solutions, in the presence of EDTA and KCN, at pH 9-11. The Hg(DDTC)2 complex, also extractable under these conditions, does not absorb at 400 nm. Some tartrate should be added, if A1, Ti, or other hydrolysable elements are present. Bismuth has been determined with the use of zinc dibenzyldithiocarbamate (CC14, 8 = 1.2.104, at 370 nm) [17,18], lead tetramethylenedithiocarbamate [19], and pyrrolidinedithiocarbamate [20].
Reagents Sodium diethyldithiocarbamate (Na-DDTC): 0.2 % solution, adjusted to pH 8-9 by adding ammonia. Standard bismuth solution: 1 mg/ml, preparation as in Section 10.2.1.
Procedure To a solution, containing not more than 0.5 mg Bi, add 2 ml of 10% EDTA solution, neutralize with conc. ammonia, and add 2 ml in excess. Then add 2 ml of 10% KCN and 1 ml of Na-DDTC. Shake the solution with 2 portions of CC14. Dilute the extract with the solvent up to the mark in a 25 ml volumetric flask. Mix the solution and measure its absorbance at 400 nm using the solvent as reference.
116
10. Bismuth
10.2.3. Xylenol Orange method Xylenol Orange (formula 4.19) forms with bismuth ions, in acid medium, a water-soluble pink complex, which is a basis for determining Bi [21-25]. Maximum colour intensity of the complex is obtained in 0.05-0.1 M H2SO4 or 0.08-0.12 M HNO3. The absorption maximum of the bismuth-Xylenol Orange complex is at 540 nm, whereas that of the reagent is at 440 nm. The molar absorptivity of the complex in 0.05-0.1 M H2SO4 is 2.3-104 (a = 0.13). Iron(II1), which interferes in the determination of bismuth, is reduced to Fe(II) with ascorbic acid. By using tartaric acid, it is possible to mask Zr, Hf, Sn, and Sb. The sensitivity of reaction of the reagent with Sb is rather low. Tin can be masked conveniently with fluoride. Chloride, bromide, and iodide decompose the Bi-Xylenol Orange complex. Since chloride exerts no influence on the complexes of Xylenol Orange with Zr, Hf, Fe, and Sn, this fact can be used for determining Bi in the presence of these metals [22].
Reagents Xylenol Orange, 0.05 % solution in 0.05 M H2SO4 Standard bismuth solution: 1 mg/ml. Preparation as in Section. 10.2.1.
Procedure Place a sample at pH -~1 containing not more than 150 ~tg of Bi in a 25 ml volumetric flask. Add 1 ml of 2% ascorbic acid solution, and (after 2 min) 3 ml of the Xylenol Orange solution. Dilute with 0.05 M H2SO4 to the mark, and mix well. After 10 min, measure the absorbance at 545 nm, using a blank solution as reference.
10.2.4. Iodide method In acid medium of 0.2-2 M H2SO4 bismuth forms the orange-yellow complex BiI4-, which is the basis for determining bismuth [26]. Up to a concentration of 3% KI in the solution, the absorbance increases; above this concentration, the absorbance remains constant. Liberation of free iodine, owing to oxidation of the iodide by atmospheric oxygen or oxidizing substances present in the sample solution, is prevented by the addition of reducing agents, such as ascorbic acid, sulphite, or hypophosphite. The absorption spectrum of the bismuth iodide complex exhibits an intense maximum at 337 nm, and a less intense maximum at 465 nm. The molar absorptivity of the complex at 465 nm is 9.1.103 (a = 0.044). The anionic complex of Bi has been extracted into CHC13 as an ion-pair with the cations tetra-n-butylammonium (~=1.13.104 at 490 nm) [27], tetramethylammonium [28], benzyltributylammonium [29], tetramethylenebis(triphenylphosphonium) (extraction with 1,2-dichloroethane) [30], 1-naphthylmethyltriphenylphosphonium [31], N-octylacetamide from a surfactant medium [32], and N,N'-diphenylbenzamidine [33]. Hexadecyltributylphosphonium cation has also been proposed as a basis for determining bismuth [34]. Bismuth was determined also as a ternary complex with iodide and 1,10-phenanthroline or 2,2'-dipyridyl (extraction with cyclohexanone or nitromethane) [35]. Antimony interferes in the determination. In 1.5% KI medium antimony does not form a coloured complex, and the intensity of the colour of the bismuth complex is reduced by only about 10%.
10.2. Methods of determination
117
From a 5 M H2504 and 0.001 M KI medium the Bi complex can be extracted by benzene (as in the case of the Sb complex). At a KI concentration increased to 0.05 M no more bismuth is extracted, whereas the extraction of Sb is practically complete. The extraction of BiI3 with benzene from H2504 solution containing small concentrations of KI forms the basis of the very sensitive indirect starch-iodine amplification method for determining bismuth [36,37]. From the benzene extract, washed with dilute H2SO4, the BiI3 is re-extracted with water. Iodide is then oxidized to IO3-, which reacts with added KI to release iodine, which is determined by the starch-iodine method (see Section 25.2.1). For each atom of bismuth (in BiI3), 18 atoms of iodine are released. The molar absorptivity e is about 3.2.105 (a = 1.5) [36]. A 48-fold increase in sensitivity of the method has been attained after re-extraction of BiI3, adding Br2, and measurement of absorbance of the I3- formed [37].
Reagents Potassium iodide, 20% solution. Standard bismuth solution: 1 mg/ml (preparation as in Section 10.2.1).
Procedure To a solution in a 25-ml standard flask, containing not more than 0.4 mg of Bi, add 3 ml of H2SO4 (1+1), 1 ml of 2% ascorbic acid, and 5 ml of KI solution. Dilute the solution to the mark and mix well. After 5 min, measure the absorbance of the solution at 465 nm vs. water.
10.2.5. Other methods Thiourea, (H2N)2C=S, forms a cationic, yellow complex with Bi, stable in acid medium. The complex is the basis of a rather insensitive method for determining bismuth [38-40]. At 470 nm, the molar absorptivity is 9.0.103. The colour of the complex varies slightly, depending on the acid present in the solution. Usually-~ 1M HNO3 is used. The concentration of thiourea in the solution must be high (-- 6% ). Coloured complexes are also formed by thiourea with Sb, Pd, Fe(III), Os, and Ru. The thiourea-Bi complex can be extracted into TBP [38] or MIBK from HC104 medium. Bismuth has been determined with thiourea after pre-concentration on an appropriate cation exchanger [41]. Cyclic urea derivatives have also been suggested for determining bismuth [42]. Many other sulphur reagents have been proposed for determination of Bi, including Bismuthiol II (formula 49.1) and its derivatives [43], 8-mercaptoquinoline (thio-oxine) (formula 4.44) [44], thiobarbituric acid (~ = 2.4-104 at 416 nm) [45] and dithiobenzoylmethane [46]. Several azo reagents have been used for determining bismuth, e.g., PAN [47], 5-BrPADAP (formula 4.7) (e = 4.9-104 at 583 nm) [48], PAR and related reagents [49], Arsenazo III [50], and 2,3,4-trihydroxy-4'-sulphoazobenzene (e = 5.5.10 4 at 460 nm) [51 ]. Some basic dyes form ion-associates with Bil4- that can be used in sensitive methods for determining bismuth. Extractable compounds are formed with Rhodamine B, Butylrhodamine B, and Rhodamine 6G (benzene, e = 1.1.105) [52], and with the azo dye (formula 10.1, e = 9.2-104) [53]. The ion-associate of the bromide complex of Bi with Rhodamine 6G has been floated with DIPE and then dissolved in ethanol (~ = 1.5.105) [54].
118
10. Bismuth
H3C--i ~--N--~--~N~ N(C2t"ls)z HC~NIN I CH3
(10.1)
The anionic complex formed by bismuth(III) and Alizarin S gives floatable sparingly soluble ion-associates with some basic dyes. The best results have been obtained with Brilliant Green (flotation with CC14-toluene mixture, dissolution of the separated compound in ethanol, e = 2.2.105) [55]. Other organic reagents used for spectrophotometric determination of Bi, include Bromopyrogallol Red [56], Pyrogallol Red [57], 3-nitrophenylfluorone (e = 5.0.104) [58], and Pyrocatechol Violet [59].
10.3. Analytical applications The dithizone method has been applied for determining bismuth in natural waters [9], platinum [12], gold [15], silver [5], tin [60], and tellurium [61]. The Xylenol Orange method has been used in determinations of Bi in copper [62,63], nickel [63], lead [64], and silver [62]. Xylenol Orange has been used in determining Bi by flow injection analysis [65]. The iodide method was used in determinations of bismuth in pharmaceuticals [66], sea water, A1 and Bi alloys [37], organic compounds [67], lead and its alloys [ 1,26], copper and its alloys [1,29,68], cast iron and steel [69], antimony [70], and sulphide concentrates [1]. After extraction of the iodide complex with various organic cations, Bi was determined in water and soil [32], pharmaceuticals [31 ], soil and ores [33], and copper alloys [31 ]. Thiourea and its derivatives were used for determining Bi in various metals [39] and ores [71]. Bi was determined in pharmaceutical preparations as the ion-pair of BiI4- with the proliptinium cation (CHC13) [72]. Bismuth has been determined in copper alloys using 2,6-Dichloroarsenazo [73].
References 1. Donaldson E.M., Talanta, 25, 131 (1978); 26, 1119 (1979). 2. Karadakov B., Sakharieva M., Anal. Chim. Acta, 125, 149 (1981). 3. Mottola H.A., Sandell E.B.,Anal. Chim. Acta, 24, 301; 25, 520 (1961). 4. Poladyan V.E. et al., Ukr. Khim. Zh., 51,743 (1985). 5. Marczenko Z., Kasiura K., Chem. Anal. (Warsaw), 9, 87 (1964). 6. Blakeley S.J., Manson A., Zatka V.J.,Anal. Chem., 45, 1941 (1973). 7. Matsumoto K., Anal. Chim. Acta, 123, 297 (1981). 8. Nakashima S., Z. Anal. Chem., 303, 10 (1980). 9. Portmann J.E., Riley J.P., Anal. Chim. Acta, 34, 201 (1966). 10. Strelow F.W., Van der Walt T.N., Anal. Chem., 53, 1637 (1981). 11. Fritz J.S., Garralda B.B., Anal. Chem., 34, 102 (1962). 12. Marczenko Z., Kasiura K., Krasiejko M., Mikrochim. Acta, 1969, 625. 13. Meintjies E., Strelow F.W., Victor A.H., Talanta, 34, 401 (1987). 14. Astafeva I.N., Shcherbov D.P., Plotnikova R.N., Zh. Anal. Khim., 30, 147 (1975). 15. Marczenko Z., Kasiura K., Krasiejko M., Chem. Anal. (Warsaw), 14, 1277 (1969). 16. Bidleman T.F., Anal. Chim. Acta, 56, 221 (1971). 17. Yamane T., Suzuki T., Mukoyama T., Anal. Chim. Acta, 62, 137 (1972).
References 18. Yamane T., Mukoyama T., Sasamoto T., Anal. Chim. Acta, 69, 347 (1974). 19. Szpunar-Lobifiska J., Anal. Chim. Acta, 251, 275 (1991). 20. Lau H.K., Droll H.A., Lott P.F., Anal. Chim. Acta, 56, 7 (1971). 21. Onishi H., Ishiwatari N., Talanta, 8, 753 (1961). 22. Cheng K.L., Talanta, 5, 254 (1960). 23. Onishi H., Ishiwatari N., Bull. Chem. Soc. Jpn., 33, 1581 (1960). 24. Kantcheva D., Nenova P., Karadakov B., Talanta, 19, 1450 (1972). 25. Pyatnitskii I.V. et al., Zh. Anal. Khim., 37, 1458 (1982). 26. Englis D.T., Burnett B.B.,Anal. Chim. Acta, 13, 574 (1955). 27. Hasebe K., Taga M., Talanta, 29, 1135 (1982). 28. E1-Shahavi M.S., Aldaheri S.M., Fresenius'J. Anal. Chem., 354, 200 (1996). 29. Barakat S.A., Anal. Chim. Acta, 355, 167 (1997). 30. Burns D.T. et al., Anal. Chim. Acta, 225, 449 (1989). 31. Burns D.T., Chimpalee D.,Anal. Chim. Acta, 211, 305 (1988); 256, 87 (1992). 32. Sharma M., Patel K.S., Ann. Chim. (Rome), 84, 467 (1994). 33. Ghosh A., Patel K.S., Mishra R.K., Bull. Chem. Soc. Jpn., 62, 3675 (1989). 34. Burns D.T., Tungkananuruk N., Anal. Chim. Acta, 197, 285 (1987). 35. Buhl F., Kania K., Chem. Anal. (Warsaw), 18, 369 (1973); 20, 1055 (1975). 36. Marczenko Z., Zo~dek I., Limbach A., Chem. Anal. (Warsaw), 14, 741 (1969). 37. E1-Shahawi M.S., Kamal M.M., Anal. Sci., 11,323 (1995). 38. Aoki F., Tomioka H., Bull. Chem. Soc. Jpn., 38, 1557 (1965). 39. Rublev V.V., Buzina N.I., Kosychenko L.I., Zh. Anal. Khim., 28, 1351 (1973). 40. Desai G.S., Shinde V.M., Bull. Chem. Soc. Jpn., 64, 1951 (1991). 41. Hoshi S., Notoya N., Uto M., Matsubara M., Anal. Sci., 7, 657 (1991). 42. Presnyak I.S. et al., Zh. Anal. Khim., 45, 1548 (1990). 43. Busev A.I., Simonova L.N., Gaponiuk E.I., Zh. Anal. Khim., 23, 59 (1968). 44. Suprunovich V.I., Vashchenko S.T., Zh. Anal. Khim., 37, 632 (1982). 45. Morelli B., Analyst, 107, 282 (1982). 46. Dolgorev A.V., Lysak Ya.G., Zibarova Yu.F., Zavod. Lab., 44, 1050 (1978). 47. Rakhmatullaev K., Gyasov A.S., Zavod. Lab., 55, No 5, 14 (1989). 48. Salim R., Shraydeh B., Microchem. J., 32, 83 (1985). 49. Nevskaya E.M., Shelikhina E.I., Antonovich V.P., Zh. Anal. Khim., 30, 1560 (1975). 50. Barkovskii V.F., Povet'eva Z.N., Zavod. Lab., 35, 555 (1969). 51. Gambarov D.G., Guseinov A.G., Zh. Anal. Khim., 39, 837 (1984). 52. Shestidesyatnaya N.L., Milyaeva N.M., Ukr. Khim. Zh., 41, 84 (1975). 53. Busev A.I., Shestidesyatnaya N.L., Kish P.P., Zh. Anal. Khim., 27, 998 (1972). 54. Chwastowska J., Pruszkowski K., Chem. Anal. (Warsaw), 21,525 (1976). 55. Flyantikova G.V., Isakhanova A.T., Zh. Anal. Khim., 37, 1452 (1982). 56. Nemcova I., Pe~inova H., Suk V., Microchem. J., 30, 27 (1984). 57. Wyganowski C., Chem. Anal. (Warsaw), 26, 307 (1981). 58. Antonovich V.P. et al., Zh. Anal. Khim., 30, 1566 (1975). 59. Honov~ D., N6mcov~ I., Suk V., Talanta, 35, 803 (1988). 60. Marczenko Z., Kasiura K., Chem. Anal. (Warsaw), 10, 449 (1965). 61. Kasterka B., Kwiatkowska-Sienkiewicz K., Chem. Anal. (Warsaw), 18, 1153 (1973). 62. Bagdasarov K.N. et al., Zavod. Lab., 34, 1306 (1968). 63. Adamiec I., Chem. Anal. (Warsaw), 13, 147 (1968). 64. Nan Z., Yu R., Yao X., Lu Z., Talanta, 36, 733 (1989). 65. Trojanowicz M., Augustyniak W., Hulanicki A., Mikrochim. Acta, 1984 II, 17. 66. Burns D.T., Dangolle C.D., Anal. Chim. Acta, 337, 113 (1997).
119
120 67. 68. 69. 70. 71. 72. 73.
10. Bismuth Hassan H.N., Hassouna M.E., Gawargious Y.A., Talanta, 53, 311 (1988). Norwitz G., Galan M., Anal. Chim. Acta, 83, 289 (1976). Koch O.G., Z. Anal. Chem., 255, 269 (1971). Presnyak I.S., Antonovich V.P., Nazarenko V.A., Zavod. Lab., 53, No 1, 13 (1987). Shelikhina E.I., Presnyak I.S., Nazarenko V.A., Zavod. Lab., 54, No 8, 15 (1988). Burns D.T., Dunford M.D., Anal. Chim. Acta, 334, 209 (1996). Zhang H.-S. et al., Anal. Chim. Acta, 380, 101 (1999).
Chapter 11. Boron Boron (B, at. mass 10.81) is a metalloid with properties somewhat similar to those of silicon. In chemical analysis, only boron(III) compounds are of importance. Boron forms complexes with fluoride and polyalcohols (e.g., mannitol and glycerol). In an anhydrous medium, boric acid reacts with methanol to form the volatile trimethyl borate.
11.1. Methods of separation and preconcentration 11.1.1. Distillation Distillation of boron as the volatile trimethyl borate (b.p. 65~ is the most common method of isolating boron before its spectrophotometric determination [ 1-4]. When separating small amounts of boron, a quartz distillation apparatus should be used since laboratory glassware contains boron. An anhydrous medium promotes the quantitative formation and distillation of methyl borate (water hydrolyses the ester). The usual procedure is to add methanol and concentrated sulphuric acid to a dried sample, and heat the still in a glycerol- or oil-bath, gradually raising the temperature to about 120~ The distillate is collected in a quartz or platinum receiver containing dilute NaOH solution (see Section 11.2.1). If the sample solution contains fluoride, boron partly distils as volatile BF3. This is prevented by masking fluoride as the stable aluminium complex. Colloidal silica partially traps boron, thus inhibiting its quantitative distillation. Traces of boron have been separated as trimethyl borate by microdiffusion methods [5]. Volatilization of trace amounts of boron as fluoride BF3 is also utilized before its determination [6,7]. Pyrohydrolysis at 900-1,200~ in a stream of superheated steam, decomposes metal borides and enables the separation of boron as the fairly volatile boric acid [8,9].
11.1.2. Extraction With the tetraphenylarsonium cation, the fluoroborate anion forms an ion-pair, which can be extracted with chloroform. Quantitative conversion of boron into BF4-, and subsequent quantitative extraction are ensured by using an excess of fluoride (at pH 2-3), and by leaving the solution to react for sufficient time before extraction [7]. Boric acid is often extracted from acidic solutions (1-6 M HC1) with 2-ethyl-l,3-hexanediol in CHC13 [10-14], with 2,2,4-trimethyl- 1,3-pentanediol in CHC13 [ 15], or with 2-methyl-2,4-pentanediol in CHC13 [16] or in MIBK [17].
11.1.3 Ion-exchange and other methods From a weakly acid solution A1F63-, 8042-, PO4 3-, and NO3- can be retained on anionexchangers, while boric acid, being only very slightly dissociated, is eluted. Borate ions can be absorbed on anion-exchangers only in neutral or alkaline media. Strongly basic anionexchangers retain traces of boron as BF4- from dilute solutions of hydrofluoric acid [18]. The
122
11. Boron
boric acid-mannitol complex can also be retained on anion-exchangers [19]. In the analysis of a number of materials (e.g., silicon- and germanium compounds and volatile reagents) traces of boron are pre-concentrated and boron is then separated by volatilization of the matrix. Mannitol, which forms a non-volatile complex with boric acid, is added to retain all the boron present in the residue [20]. Boron is fairly volatile in acidic media. While boron traces are determined in chlorosilanes, it is advisable to add some chlorotriphenylmethane [21], which forms a non-volatile compound with boron thus preventing its volatilization, when the matrix is evaporated. Ref. 21 is not cited. Trace amounts of boron can be concentrated by specific adsorption on a column of Sephadex G-25 [22].
11.2.
Methods of determination
The very sensitive curcumin method is often used for determining trace amounts of boron. The carmine-acid method is much less sensitive. Extraction-spectrophotometric methods based on ion-associates of BF4- with Methylene Blue and other basic dyes are of importance in the determination of boron.
11.2.1. Curcumin method Curcumin is a natural compound extracted from the curcuma root and purified by crystallisation. It has the formula:
HO~CH---CH
\""/ / H3CO
CH
\c / ~ c / II 0
.CH=CH~OH
IH O
\"J/
kOCH,
(11.1)
The reagent, classified as a [3-diketone dissolves, giving a yellow colour, in methanol, ethanol, acetone, and glacial acetic acid. In acid media, curcumin and boron form a violetred 2:1 complex called rosocyanin. The sensitivity of the method and the reproducibility of the results obtained depend on the quality of the curcumin reagent, and on rigorous observance of the reaction conditions (temperature, time, reagent quantities) [23-25]. Commercial curcumin samples differ considerably in quality. Under the most favourable conditions, the molar absorptivity of rosocyanin is 1.8.105 at ~max = 550 nm (a = 16.6). In a modification of the curcumin method, a ternary complex is formed between curcumin, boron, and oxalic acid [26]. The method is more rapid, but it is only about half as sensitive. The ternary complex formed (rubrocurcumin) contains curcumin, boron, and oxalate in the ratio 1:1:1. Numerous elements (e.g., Be, Fe, Ge, Mo, Ti) form coloured complexes with curcumin, and interfere in the determination of boron. Oxidants (e.g., HNO3) , and substances forming stable complexes with boron (e.g., HF), also interfere. In general, therefore, boron is first separated by distillation as trimethyl borate.
11.2. Methods of determination
123
Reagents Curcumin, 0.1% solution in glacial acetic acid (25 mg of curcumin in 25 ml of the solvent). The solution is prepared on the day of use. Standard boron solution: 1 mg/ml. Dissolve 0.5716 g of H3BO3 in water, and dilute the solution with water to 100 ml in a volumetric flask. Mixture of conc. H2804 and glacial CH3COOH (1 + 1). Mix equal volumes of the two acids immediately before use. Alkaline solution. Dissolve 1 g of NaOH in 100 ml water, add 3 g of glycerol. Store the solution in a polyethylene bottle. Methanol. Purify by distillation from solid NaOH in a quartz still. Store in a polyethylene bottle. Quartz distillation apparatus. Distillation flask of capacity 50-75 ml. The distance between the bulb of the distillation flask and the side-arm should be at least 10 cm.
Procedure
Separation of boron by distillation. Evaporate an alkaline sample solution containing a microgram quantity of boron to dryness. If it is necessary to ignite and fuse the residue (e.g., if mannitol is present), a platinum vessel should be used. Add to the solid residue 1-2 ml of conc. H2804, stir with a glass rod, and wash the contents of the vessel with 25 ml of methanol into a distilling flask fitted with a condenser. Immerse the condenser tip in a trapping solution (2 ml of the alkaline solution and 18 ml of H20) contained in a platinum dish. Distil the contents of the still by heating on a glycerol bath; at the end of distillation the temperature should be 120~ After all the methanol has been distilled off, cool the still, add 10 ml of methanol, and repeat the distillation.
Determination of boron. Take an aliquot (containing < 1 ~tg B) of the distillate, and evaporate it to dryness in a platinum crucible. Ignite the residue until all the organic matter has been burned off and the mineral residue has been melted. Place the crucible in a water bath at exactly 60~ add from a pipette exactly 2.5 ml of curcumin solution, and keep the vessel on the bath for about 3 min with occasional stirring. To the cooled vessel, add 1 ml of the HzSO4-CH3COOH mixture, and mix thoroughly by swirling the vessel. After 20 min wash the contents with ethanol ( 7 0 % ) into a 25-ml volumetric flask and dilute to the mark with ethanol. Mix the solution, and measure its absorbance at 550 nm, using the blank solution as a reference.
Notes. 1. The blank solution must be prepared very carefully. 2. If boron is determined without distillation as trimethyl borate, any traces of HF or HNO3 must be carefully removed before the addition of curcumin (e.g., by evaporating the solution 2 or 3 times with dilute HC1 in the presence of mannitol).
11.2.2. Carminic acid m e t h o d Carminic acid belongs to the group of boron reagents derived from a-hydroxyanthraquinone. These reagents give coloured complexes with boron in conc. sulphuric acid medium. Boron occurs as the B 3+ cation in conc. H2804, and as BO + in less concentrated H2804. Carminic acid (also called carmine or Carmine Red) is a natural product obtained from cochineal. In concentrated sulphuric acid medium carminic acid reacts with boron(III):
124
11. Boron j B z~ CH3
0
OH
CH3 COICHOHII'CH3
.o- T
HOOC
Y 0
T
OH
-o.
O
"~
B=,
conc.s,s0,
.o- T
HOOC
T 0
T
OH
-o. (11.2)
The reagent is red (~max -- 520 nm), whereas the boron complex is violet-blue [27]. The molar absorptivity of the complex at 615 nm (vs. reagent solution as the reference) is 5.5.103 (a = 0.51). Boron reacts slowly with carminic acid. The reaction may be accelerated by diluting the H2804 (e.g., to -~92%), but the acid concentration should not be lower than 90%. The absorbance reaches a maximum within 45-60 min, after which it remains constant for a few hours. Oxidising agents and fluoride interfere in the carminic acid method [28-31 ]. Before its determination, boron is normally separated either as volatile trimethyl borate or by other methods. Carminic acid solutions in conc. H2SO4 and glacial CH3COOH were added directly to the chloroform extract of boron with 2,2,4-trimethyl- 1,3-pentanediol [ 15].
Reagents Carminic acid solution: Dissolve 25 mg of the reagent in 100 ml of conc. sulphuric acid. Standard boron solution: 1 mg/ml. Preparation as in Section 11.2.1.
Procedure Place 2.5 ml of acidic solution (-~4 M H2804), containing not more than 25 lag of B, in a 25ml standard flask. Add 5 drops of conc. HC1, 12.5 ml of conc. H2804, and carmine solution up to the mark. Mix the solution thoroughly and set aside for 1 h. Measure the absorbance of the solution at 650 nm, using a blank solution as reference.
Note. If boron is separated by distillation, evaporate the distillate to dryness, and dissolve the residue in 2.5 ml of 4 M H2804. 11.2.3. Methylene Blue method The sensitive method for determination of boron has been based on an extractable ionassociate of the anionic complex BF4-with Methylene Blue (MB) (formula 48.1) [32-35]. Formation of the boron complex in acidic (H2804) solution is not very rapid after the addition of fluoride in excess; it requires some time at room temperature. The sulphuric acid concentration can be 0.2-0.8 M , and concentrations of -~0.4 M for fluoride and --2.10 -4 M for Methylene Blue are suitable. Under these conditions, BF4- is formed in --30 min. Before extraction of the ion-pair, the sample solution should be diluted to reduce the acidity. 1,2Dichloroethane is the most recommended solvent for the extraction of the boron ion-pair; a good quality solvent is important for good extraction. Polyethylene separating funnels must be used because of the hydrofluoric acid medium. The molar absorptivity of the 1,2-dichloroethane solution of the MB-BF4- ion-pair is 8.2.104 (a = 7.6) at 665 nm. Ions giving extractable ion-pairs with MB interfere (e.g., C104-, SCN-). Usually the method is applied after a distillative separation of boron.
11.2. Methods of determination
125
Reagents Methylene Blue (MB), 1.2-10 -3 M (--0.05%) solution. Standard boron solution: 1 mg/ml. Preparation as in Section 11.2.1.
Procedure To a 100-ml separating funnel, add sample solution containing not more than 2.5 /ag of B, then 2.5 ml of 10% NaF solution, and enough H2SO4 to give, finally, 8 ml of the solution, at concentration of about 0.4 M. After 30 min, add 40 ml of water, 10 ml of the MB solution, and shake the solution with two 10-ml portions of 1,2-dichloroethane (shaking time 1 min). Dilute the clear extract to volume with solvent in a 25-ml standard flask, mix well, and measure the absorbance of the solution at 665 nm, using the blank solution as a reference.
11.2.4 Other Methods Besides the Methylene Blue, other spectrophotometric methods, based on ion-associates of anionic boron complexes with basic dyes are used. Extractable associates with BF4- are obtained with Nile Blue A (formula 4.32) [7,36,37], Capri Blue (formula 4.31) [38], Malachite Green (formula 4.26, with Me instead of Et), Chrompyrazole II (CHC13, e = 6.7.104 at 595 nm) [40], etc. In addition to BF4-, other anionic boron complexes, also forming ion-associates with basic dyes, have been applied to determine boron, namely: 2,4-dinitro-l,8-naphthalenediol and Brilliant Green (formula 4.26) (toluene, e - 1.0.105 at 637 nm [41-43], 2,6-dihydroxybenzoic acid, and Malachite Green (chlorobenzene, e - 9.5.104 [5], 2,3-dihydroxynaphthalene and Crystal Violet (benzene, e = 8.8-104 [44]), mandelic acid, and Malachite Green (benzene, e = 6.5.104 ) [45,46], pyrocatechol derivatives, and Ethyl Violet (toluene, e = 1.05-104 [47,48]. The ion-pair of the salicylate complex of boron with ferroin has also been proposed (CHC13) [49]. 1,1'-Dianthrimide (1,1'-dianthraquinonyl amine) reacts with boron in a conc. H2SO4 medium, after heating at 70-90~ for 2-4 h. A complex with the following structure is obtained:
0
O'-'i'-O 2+
0
(11.3)
The colour of 1,1'-dianthrimide in conc. H2804 is olive-green, whereas that of the boron complex is dark blue (e - 1.9.104 at 630 nm) [50]. Azomethine H, the product of the condensation of H-acid (1-amino-8-naphthol-3,6disulphonic acid) and salicylaldehyde (formula 11.4) is often used for determining boron. The colour reaction is carried out in acetate buffer (pH --5.2) in the presence of ascorbic acid. The absorbance is measured at 415 nm after 2 h.
126
11. Boron
HO3S N=CH~ OH
(11.4)
HO/
HO3S/
11.3. Analytical applications The curcumin method (in either the rosocyanin or rubrocurcumin version) has been applied for determining trace amounts of boron in: biological materials [10], soils and plants [ 17], waters [51 ], silicon [52], chlorosilanes [20], uranium [1,53], zirconium and its alloys [53,54], nickel [55,56], copper alloys [56], cast iron and steel [12,57-59], beryllium and magnesium [53], and phosphates [2]. This method was also used for determining boric acid admixtures (about 0.05%) in powdered boron [11]. Some synthetic compounds having the structure similar to that of curcumin, were used in determining boron in water [60]. The earminie acid method has been applied for determining boron in geological materials [6,13,61], silicon [62], nickel and cobalt [63], magnesite [64], glass [65], and fertilizers [66]. An automatic method has been applied for determining boron in sewage and in river water [67]. The Methylene Blue method has been utilized in determinations of boron in biological materials [33], soils and rocks [68], steels [32], silicon [7,69], copper and its alloys [34,35], and various chemical materials [70,71 ]. Boron has been determined by the 1,1'-dianthrimide method in biological materials [72], dairy products [73], cast iron and steel [44], and nickel alloys [74]. The method with azomethine H has been used for determining boron in plant materials [75], biological samples [76], plants [77], soils [77-79], water [80], sewage [4,81 ], rocks and bituminous [22,55,82], steel [47], copper, nickel, and cobalt alloys [9], boron nitride [83], and fertilisers [84]. Azomethine H has been utilized in automatic determination of boron [81] and in flow injection analysis (FIA) [75]. Boron has also been determined in plants and soils with the use of 4-methoxyazomethine H [85].
References 1. Onishi H., Ishiwatari N., Nagai H., Bull. Chem. Soc. Jpn, 33, 830 (1960). 2. Kocher J., Bull. Soc. Chim. France, 1962, 1247. 3. Landry J.C., Landry M.F., Monnier D., Anal. Chim. Acta, 62, 177 (1972). 4. Monzo J., Pomares F., de la Guardia M., Analyst, 113, 1069 (1988). 5. Shida J., Suzuki H., Abe S.,Anal. Chim. Acta, 169, 349 (1985). 6. Farzaneh A., Troll G., Neubauer W., Z. Anal. Chem., 296, 383 (1979). 7.Grallath E., Tsch6pel P., K61blin G., Stix U., T61g G., Z. Anal. Chem., 302, 40 (1980). 8. McKinley G.J., Wendt H.F., Anal. Chem., 37, 947 (1965). 9. Ciba J., Stankiewicz W., Matusiak H., Z. Anal. Chem., 321, 592 (1985). 10. Mair J. W., Day H.G., Anal. Chem., 44, 2015 (1972). 11. Grotheer E. W., Anal. Chem., 51, 2402 (1979).
References 12. Donaldson E.M., Talanta, 28, 825 (1981). 13. Troll G., Sauerer A.,Analyst, 110, 283 (1985). 14. Betty K.R., Day G.T.,Analyst, 111,455 (1986). 15. Aznarez J., Ferrer A., Rabadan J.M., Marco L., Talanta, 32, 1156 (1985). 16. Aznarez J., Mir J. M.,Analyst., 109, 183 (1984). 17. Aznarez J., Bonilla A., Vidal J.C., Analyst, 108, 368 (1983). 18. Semov M.P., Zh. Anal. Khim., 23, 245 (1968). 19. Barbier Y., Rosset R., Bull. Soc. Chim. France, 1968, 5072. 20. Marczenko Z., Mojski M., Kasiura K., Chem. Anal. (Warsaw), 14, 1331 (1969). 21. Kawasaki K., Higo M., Anal. Chim. Acta, 33, 497 (1965). 22. Yoshimura K., Kariya R., Tarutani T.,Anal. Chim. Acta, 109, I15 (1979). 23. Uppstr6m L.R., Anal. Chim. Acta, 43, 475 (1968). 24. Dyrssen D. W., Novikov Y.P., Uppstr6m L. R., Anal. Chim. Acta, 60, 139 (1972). 25. Quint P., Umland F., Z. Anal. Chem., 295, 269 (1979). 26. Quint P., Umland F., Sommer H.D., Z. Anal. Chem., 285, 356 (1977). 27. Schwing-Weill M.J.,Analusis, 14, 290 (1986). 28. Gupta H.K., Boltz D.F., Mikrochim. Acta, 1974, 415. 29. F16chon J., Kuhnast F.A., Bull. Soc. Chim. France, 1976, 739. 30. Rosenfeld H.J., Selmer-Olsen A.R., Analyst, 104, 983 (1979). 31. Samsoni Z., Szeleczky M.A., Mikrochim. Acta ,1980 I, 445. 32. Blazejak-Ditges D., Z. Anal. Chem., 247, 20 (1969). 33. Yoshino K. et al., Anal. Chem., 56, 839 (1984). 34. Ci~ek Z., Studlarov~ V., Talanta, 31,547 (1984). 35. Kleimenova O.K., Dedkov Yu D., Zavod. Lab., 55, 3 (1989). 36. Gagliardi E., Wolf E., Mikrochim. Acta, 1968, 140. 37. Nicholson R.A., Anal. Chim. Acta, 56, 147 (1971). 38. Buldini P.L., Anal. Chim. Acta, 82, 187 (1976). 39. Xing-Chu Q., Ying-Quan Z., Analusis, 14, 46 (1986). 40. Busev A.I., Yakovlev P. Ya., Kozina G. V., Zh. Anal. Khim., 22, 1227 (1967). 41. Kuwada K., Motomizu S., T6ei K., Anal. Chem., 50, 1788 (1978). 42. T6ei K., Motomizu S., Oshima M., Watari H., Analyst, 106, 776 (1981). 43. Fogg T.R., Duce R.A., Fashing J.L.,Anal. Chem., 55, 2179 (1983). 44. Sato S., Uchikawa S., Anal. Chim. Acta, 143, 283 (1982). 45. Sato S.,Anal. Chim. Acta, 151,465 (1983). 46. Sato S., Talanta, 32, 447 (1985). 47.0shima M., Motomizu S., T6ei K., Anal. Chem., 56, 948 (1984). 48. Oshima M., Shibata K., Gyouten T., Motomizu S., T6ei, Talanta, 35, 351 (1988). 49. Bassett J., Matthews P.J., Analyst, 99, 1 (1974). 50. Gupta H.K., Boltz D.F., Anal. Lett., 4,161 (1971). 51.0stling G.,Anal. Chim. Acta, 78, 507 (1975). 52. Parashar D.C., Sarkar A.K., Singh N., Anal. Lett., 22, 1961 (1989). 53. Hayes M.R., Metcalfe J., Analyst, 87, 956 (1962). 54. Ishikuro M., Kimura J., Bunseki Kaguku, 37, 498 (1988). 55. Andrew T.R., Nichols P.N., Analyst, 91, 664 (1966). 56. Pakalns P., Analyst, 94, 1130 (1969). 57. Tolk A., Tap W.A., Lingerak W.A., Talanta, 16,111 (1969). 58. Thierig D., Z. Anal. Chem. 310, 154 (1982). 59. Vialatte A., A16v~que J., Guinot H., Taupe A.,Analusis, 11,446 (1983). 60. Lambert I.L., Paukstelis J. V., Bruckdorfer R.A., Anal. Chem., 50, 820 (1978).
127
128
11. Boron
61. Kiss E.,Anal. Chim. Acta, 211,243 (1988). 62. Chen J.S., Lin H.M., Yang M.H., Fresenius'J. Anal. Chem., 340, 357 (1991), 63. Norwitz G., Gordon H., Anal. Chim. Acta, 94,175 (1977). 64. Shelton N.F., Reed R.A., Analyst, 101, 396 (1976). 65. Reed R.A., Analyst, 102, 831 (1977). 66. Peterson H.P., Zoromski D.W., Anal. Chem., 44, 1291 (1972). 67. Lionnel L.J., Analyst, 95, 194 (1970). 68. Stanton R.E., McDonald A.J., Analyst, 91, 775 (1966). 69. Lanza P., Buldini P.L., Anal. Chim. Acta, 70, 341 (1974). 70. Beskova E.S., Zhuravlev G.I., Zh. Anal. Khim., 28,1411 (1973). 71. K6the J., Ackerman G., Z. Anal. Chem., 320, 545 (1985). 72. Kaczmarczyk A., Messer J.R., Peirce C.E., Anal. Chem., 43,271 (1971). 73. Raber H., Likussar W., Mikrochim. Acta, 1970, 577. 74. Burke K.E., Albright C.H., Talanta, 13, 49 (1966). 75. Krug F.J. et al., Anal. Chim. Acta, 125, 29 (1981). 76. Ciba J., Chru~ciel A., Fresenius'J. Anal. Chem., 342, 147 (1992). 77. Carrero P., Burguera J.L., Burguera M., Rivas C., Talanta, 40, 1967 (1993). 78. Chen D. et al., Anal. Chim. Acta, 226, 221 (1989). 79. Kaplan D.I., et al., Soil Sci. Soc. Am. J., 54, 708 (1990). 80. Lopez F.J., Gimenez E., Hernandez F., Fresenius' J. Anal. Chem., 346, 984 (1993). 81. Edwards R.A.,Analyst, 105, 139 (1980). 82. Schucker G.D., Magliocca T.S., Yao-Sin S.,Anal. Chim. Acta, 75, 95 (1975). 83. Mikhailovskaya V.S., Martunova L.M., Buyanovskaya A.G., Sinenko Yu.A., Zh. Anal. Khim., 47, 1331 (1992). 84. Hofer A., Brosche E., Heidinger R., Z. Anal. Chem., 253,117 (1971). 85. Zaijun L,. Zhu Z., Jan T.,Anal. Chim. Acta, 402, 253 (1999).
Chapter 12. B r o m i n e Bromine (Br, at. mass 79.91) is a dark red-brown liquid. Saturated bromine water contains 3.6% (w/v) of bromine (at 20~ Bromine forms bromide (Br-) and hypobromite (BrO-) in alkaline solution. The most stable forms of bromine are bromide and bromate (BrO3-). Bromide has reducing properties, whereas bromine (Br2), hypobromite, and bromate are oxidants. Many bromides are sparingly soluble compounds, and soluble bromide complexes are formed with the same metals as form soluble chloride complexes.
12.1 Separation of bromide and bromine Bromine is volatile and can be distilled from acidified solutions. Bromide is most often separated by distillation after oxidation to bromine [1]. Distillation is carried out in a stream of gas such as air, nitrogen, or carbon dioxide. It is possible to separate iodide, bromide, and chloride from each other by selective oxidation. First, the iodine produced by oxidation of iodide with hydrogen peroxide in phosphoric acid medium (pH -~1) is distilled. Then dilute nitric acid (2.5-4 M) is used to oxidize bromide to bromine. Iodide in the presence of bromide can also be oxidized with nitrite in acetic acid medium. The iodide (and subsequently the bromine) liberated can be separated by extraction into CHC13, CC14, and other solvents [1,2]. Bromide may also be separated by conversion into volatile cyanogen bromide, CNBr, in dilute H2SO4 containing cyanide and chromic acid [3]. Chloride, bromide, and iodide can be separated on a strongly basic anion exchanger, using sodium nitrate solutions of variable concentration as eluents. Bromide can be separated from many anions on the anion-exchanger Dowex 1 [4]. The sparingly soluble silver bromide allows one to separate bromide [5]. For trace amounts, chloride can be used as collector. Other methods of separating halide ions are mentioned in the Section on chlorine.
12.2. Determination of bromide and bromine The determination of bromide is, in general, based either on indirect methods, or on methods involving preliminary oxidation to bromine. The bromine formed participates in subsequent bromination or oxidation reactions to give coloured products. The bromination of Phenol Red is described below.
12.2.1. Phenol Red method Phenol Red (the triphenylmethane dye phenolsulphonaphthalein, formula 12.1) reacts with bromine to form tetrabromophenolsulphophthalein (Bromophenol Blue). The change in colour of a solution at pH 5.5 from yellow to violet is very pronounced. The reaction has been the basis of a sensitive spectrophotometric method of determining bromine [1,6-9]. The molar absorptivity, e, of the violet product at ~max -----580 nm is 1.14-10 4 (a = 0.14).
130
12. Bromine
H~ H
S03H
(12.1)
The oxidation of bromide to bromine, and the bromination of Phenol Red are carried out in a weakly alkaline medium [1]. Calcium hypochlorite can be used as oxidizing agent. The periods of time specified for oxidation (2 min) and for bromination (4 min) must be adhered to strictly (see procedure below). With longer oxidation, bromine is oxidized to bromate. An automated version of the method has been developed [8], and the FIA technique has been applied [10]. Before the distillation, bromide is oxidized to bromine with a mixture of chromic acid (0.8 M) and H2804 (7 M) [1 ]. This mixture does not oxidise chloride. During the distillation, nitrogen is used to carry the bromine into a trapping solution of 0.1 M sodium sulphite, which is a better scrubber than NaOH. Since traces of chromium(VI) are also carried into the receiver, an additional extraction of bromine is performed. Bromide in the receiver is oxidised with a cold CrO3-HzSO4 mixture, and the bromine formed is extracted into CC14. The bromine is stripped from the organic layer with 2 M ammonia, the ammonia is driven off, and the bromide determined as given below.
Reagents Phenol Red, 0.01% solution. Dissolve 10 mg of the reagent in 1 ml of 0.1 M NaOH and dilute the solution with water to 100 ml. Standard bromide solution: 1 mg/ml. Dissolve in water 1.4900 g of potassium bromide dried at 110~ and dilute the solution with water in a volumetric flask to 1 litre. Borate buffer, pH 8.7-8.8; saturated borax (NazB4Ov.10H20) solution. Calcium hypochlorite, 0.4% solution, filtered. Sodium arsenite, 0.1 M solution (13 g of salt per litre of solution). Acetate buffer, pH 4.6-4.7. Dissolve 68 g of sodium acetate trihydrate in water, add 30 ml of glacial acetic acid, and dilute the solution with water to 1 litre.
Procedure Place an approximately neutral sample solution (-~12 ml), containing not more than 100 gtg of Br-, in a 25-ml standard flask, add 4 ml of the borate buffer, 1 ml of the hypochlorite solution, and shake for 2 min. Add 1.0 ml of the Phenol Red solution, stir well, and let the solution stand for 4 min. Add 1.2 ml of the arsenite solution and 4 ml of the acetate buffer, and dilute to the mark with water. Measure the absorbance of the solution at 580 nm against a blank solution.
12.2.2 Other methods of determining bromide and bromine A group of other methods for determining bromide is based on the coloured products formed by bromination of various organic compounds by bromine produced in the oxidation of bromide. The reaction with rosaniline gives tetrabromorosaniline [11,12], and fluorescein
12.3. Determinationof bromate and perbromate
131
yields tetrabromofluorescein (eosin) [13]. The product of the reaction of bromine with fuchsine (hexabromofuchsine) can be extracted into CHC13 [14]. As with chlorine, it is possible to determine bromine from its oxidizing effect on otolidine [15,16]. Another method has been based on bleaching Methyl Orange (formula 12.2) [17,18].
(CH3)zN~N=N-~SO3H
(12.2)
Methyl Orange solutions are bleached, in the presence of bromide, under UV irradiation, and the rate of bleaching is in proportion to the bromide concentration. The method has been applied for determining bromide in the presence of other halides [ 19]. Other indirect methods involve reactions with the mercury(II) complexes of diphenylcarbazone [20] or Methylthymol Blue [21], or the displacement of thiocyanate ion from AgSCN or Hg(SCN)2 by bromide, followed by the spectrophotometric determination of thiocyanate with ferric ions [22,23]. In another method proposed, the bromide is oxidised to BrO3- by the action of persulphate [24,25]. After complete decomposition of the oxidizer, iodide is added in excess and the equivalent amount of iodine, formed in reaction with the BrO3-, is determined spectrophotometrically at 355 nm (e = 7.3.104). Bromide can also be oxidized to bromine, which is then extracted into CC14. The absorbance of the extract is measured at 417 nm [2], but this method is of rather low sensitivity.
12.3. Determination of bromate and perbromate The spectrophotometric determination of bromate can be based on the reactions of BrO3ions with o-arsanilic acid [26], antipyrine (in the presence of nitrite) [27], 1,3,4trihydroxyanthraquinone-2-carboxylic acid [28], Pyrogallol Red [29], or 2oxyminedimedonodithiosemicarbazone [30]. Perbromate ions have been extracted into chlorobenzene as ion-associates with Crystal Violet [31], or with Brilliant Green [32]. The analytical properties of perbromate (BrO4-), have been compared with the properties of perchlorate and periodate ions [33]. Chromatographic and electrophoretic methods have been developed for the separation of perbromate from other halogen compounds [34].
12.4. Analytical applications The Phenol Red method has been applied for determining bromide in water [7,8,10,35-37], food products [6], sodium chloride [38], and uranium fluorides and oxides [1 ]. The bromination reaction of organic compounds has been utilized for the determination of bromine in water [11] and in alkali-metal chlorides [12]. The reaction of bromine with fluorescein has been applied for determining bromide in blood plasma [39]. Fuchsin has been used for the determination of bromate in drinking water [40].
132
12. Bromine
References 1. Larsen R.P., Ingber N.M., Anal. Chem., 31, 1084 (1959). 2. Collins A.G., Watkins J.W., Anal. Chem., 31, 1182 (1959). 3. Winefordner J.D., Tin Maung, Anal. Chem., 35, 382 (1963). 4. Lundstr6m U., Olin A., Nydahl F., Talanta, 31, 45 (1984). 5. Koch H., Schultze K., Z. Anal. Chem., 210, 90 (1965). 6. Kretzschmann F., Engst R., Mikrochim. Acta, 1970, 270. 7. P6ron A., Courtot-Coupez J., Analusis, 6, 389 (1978). 8. Basel C.L., Defreese J.D., Whittemore D.O., Anal. Chem., 54, 2090 (1982). 9. Jones D.R.,Anal. Chim. Acta, 271,315 (1993). 10. Anf~ilt T., Twengstr6m S.,Anal. Chim. Acta, 179, 453 (1986). 11. Mold~in B., Zyka J., Microchem. J., 13, 357 (1968). 12. Joy E.F., Bonn J.D., Barnard A.J., Anal. Chem., 45, 856 (1973). 13. Oosting M., Reijnders H.F., Z. Anal. Chem., 301, 28 (1980). 14. Cogan E., Anal. Chem., 34, 716 (1962). 15. Creitz E.C., Anal. Chem., 37, 1690 (1965). 16. Scheubeck E., Ernst O., Z. Anal. Chem., 249, 370 (1970). 17. Laitinen H.A., Boyer K.W., Anal. Chem., 44, 920 (1972). 18. Metters-Tuladhar C.H., Ottaway J.M., Anal. Chim. Acta, 66, 291 (1973). 19. Dodin E.I., Kharlamov I.P., Zh. Anal. Khim., 31, 102 (1976). 20. Okutani T., J. Chem. Soc. Jpn., Pure Chem. Sect., 88, 737 (1967). 21. Nomura T., Komatsu S., J. Chem. Soc. Jpn., Pure Chem. Sect., 90, 168 (1969). 22. Kirsten W.J., Lindholm-Franzen I., Microchem. J., 25, 240 (1980). 23. Almuaibed A.M., Townshend A.,Anal. Chim. Acta, 245, 115 (1991). 24. Lundstr6m U., Talanta, 29, 291 (1982). 25. Carlsson A., Lundstr6m U., Olin A., Talanta, 34, 615 (1987). 26. MacDonald J.C., Yoe J.H., Anal. Chim. Acta, 28, 383 (1963). 27. Qureshi M., Qureshi S.Z., Zehra N., Mikrochim. Acta, 1970, 831. 28. Roman Ceba M. et al., Microchem. J., 29, 19 (1984). 29. Escriche J.M., Cabeza A.S., Penella M.M., Estelles M.L., Analyst, 110, 1467 (1985). 30. Salinas F., Sanchez J.C., Gallego J.M., Microchem. J., 37, 145 (1988). 31. Brown L.C., Boyd G.E., Anal. Chem., 42, 291 (1970). 32. Borisova I.V., Zh. Anal. Khim., 36, 2347 (1981). 33. Ossicini L., Balzoni M., J. Chromatogr., 79, 311 (1973). 34. Lederer M., Sinibaldi M., J. Chromatogr., 60, 275 (1971). 35. Jones D.R., Talanta, 36, 1243 (1989). 36. Grosse Yu.I., Zavod. Lab., 59, No 2, 6 (1993). 37. Freeman P.R., Hart B.T., McKelvie I.D., Anal. Chim. Acta, 282, 379 (1993). 38. Emaus W.J., Henning H.J., Anal. Chim. Acta, 272, 245 (1993). 39. Jennings G., Elia M., Clin. Chem. (Washington D.C.), 42, 1210 (1996). 40. Romele I., Achilli M., Analyst, 123, 291, 1998.
Chapter 13. Cadmium Cadmium (Cd, at. mass 112.40) occurs in its compounds exclusively in the II oxidation state. Unlike Zn(OH)2 and Pb(OH)2, Cd(OH)2 shows no amphoteric properties and is insoluble in excess of NaOH. Cadmium forms ammine, cyanide, halide, and EDTA complexes.
13.1. Methods of separation and preconcentration 13.1.1. Extraction Extraction of the cadmium-iodide complex from iodide-H2SO4 solutions with oxygencontaining solvents (e.g., mesityl oxide, 2-ethyl-l-butanol) is a selective recommended separation method (e.g., from zinc) [1-3]. The iodide complex of cadmium can also be extracted with high molecular weight amines in xylene [4], TBP in benzene [5], and with tetra-n-butylammonium iodide in CHC13 [6]. Cadmium has been extracted as the thiocyanate complex with TOPO in hexane. Cadmium can also be separated from numerous metals by extraction as the chloride [7-9] and bromide [7,10] complexes, mostly in the presence of organic bases. Cadmium may be extracted into CHC13 or CC14 as the dithiocarbamate [11,12]. In the presence of tartrate and cyanide at pH -~11, only Bi, Pb, and TI(III) are co-extracted with cadmium. Dithizone allows a highly selective separation of cadmium. Separation of Cd (and Zn) from Co and Ni has been described [13]. The extraction of cadmium chelates with oxine, chloro-oxine, HTTA, dibenzoylmethane, anthranilic acid, and other chelating reagents has been investigated [14,15].
13.1.2. Ion exchange. Precipitation Cadmium and zinc have been separated on a Dowex 1 anion-exchanger [16,17]. In 0.1 M HC1 solution (containing 100 g of NaCI per litre), Zn and Cd chloride complexes are retained in the column, while other metals are eluted. First, zinc is eluted from the column with 2 M NaOH (containing 20 g of NaC1 per litre ), then Cd is eluted with 1 M HNO3. The anionic chloride complex has been utilized to separate Cd from other metals. The anionic bromide- [18,19] and iodide- [20] complexes of cadmium can also be retained on anion-exchangers. When metals dissolved in 0.5 M HC1 are passed through a strongly acidic cation exchanger, Cd and Sn(IV) are eluted, whereas Zn, Cu, Mn, Ni, Co, U, and Ti are retained on the column. Cd, Sn(IV), Bi, and Hg(II) have been separated from most other metals by elution from a cation exchanger with 0.4 M HBr [21]. The effect of various media on the separation of Cd from other metals on Dowex 50 cation exchange resin has been investigated [22]. Precipitation of cadmium as the sulphide at low acidity (pH-~l.5) allows traces of cadmium to be separated from large quantities of zinc. A small amount of sodium sulphide is added to the solution to precipitate cadmium, other Group II metals, and some of the zinc, which acts as a collector. Further separation from zinc can be achieved by a dithizone extraction. Precipitation of Cd in the presence of KCN allows its separation from Cu. In all
134
13. Cadmium
these cases trace amounts of cadmium have been precipitated in the presence of a suitable carrier element [23].
13.2. Methods of determination Two sensitive methods for determining cadmium are presented in detail: the classical dithizone method, and a new method with use of the chelating azo reagent 5-Br-PADAP.
13.2.1. Dithizone method The cadmium ion reacts with dithizone (Section 4.5) in neutral to strongly alkaline media to give a pink cadmium dithizonate, which is soluble in CC14 and in CHC13. The stability of Cd(HDz)2 in strongly alkaline media (5-20% NaOH) allows cadmium to be extracted from Pb, Bi, Sn(II), and Zn, the dithizonates of which cannot exist under such conditions. Dimethylglyoxime is added to mask nickel and cobalt. Tartrate prevents the precipitation of metals as hydroxides. The noble metals (Au, Pt, Pd, Ag, Hg) and Cu must be removed before cadmium is extracted. They are most simply pre-extracted with dithizone from acid medium. The dithizone method for determining cadmium [24,25] is very sensitive. The molar absorptivity at )~max = 520 nm is 8.8.10 4 (a = 0.78). The sensitivity of the method increases in the presence of surfactants [26,27]. In the determination of cadmium with dithizone it is possible to avoid the preliminary extraction from the acidic medium. Instead, one can apply a double extraction of cadmium from alkaline solutions containing cyanide: first, from a solution containing 6-7% NaOH and 0.2% KCN, and secondly from a solution containing 6-7% NaOH and 0.01% KCN. Tartaric acid is used as stripping agent after the first extraction. A high concentration of cyanide prevents extraction of cadmium, whereas a relatively low one does not, provided sufficient dithizone is used. Such conditions allow separation of the cadmium from all but traces of Pb and Zn in the first extraction, and the stripping separates cadmium from Ag and Hg. Dilute hydrochloric acid (pH 1.5) readily decomposes Cd (and Zn) dithizonates, whereas Ni and Co dithizonates are unaffected. Thus, cadmium (together with Zn) may be separated from Ni and Co [13]. Cadmium is separated from zinc, based on the different resistance of their dithizonates to the action of alkali. To prevent oxidation of dithizone by oxygen during shaking with strongly alkaline solutions (especially those containing M n ) , hydroxylamine should be added to the aqueous solution. In the presence of 1,10-phenanthroline, at pH 3, a mixed complex, Cd(HDz)2(phen), is extracted into CHC13 ( ~3= 6.5-104 at )~max= 505 nm) [28]. Cadmium has been extracted with dithizone in the presence of excess of Zn from solutions containing methyltrioctylammonium thiocyanate [29].
Reagents Dithizone: 0.002% solution in CC14 (preparation as in Section 46.2.1). Standard cadmium solution: 1 mg/ml. Dissolve 1.6310 g of cadmium chloride, dried at 110~ in water containing 2 ml of conc. HC1, and dilute the solution with water to 1 litre. Potassium sodium tartrate, 20% solution (preparation as in Section 27.2.1). Hydroxylamine hydrochloride, 10% solution (preparation as in Section 27.2.1).
13.2. Methods of determination
135
Sodium hydroxide, 20% solution, kept in a polyethylene bottle.
Procedure Acidify a solution containing not more than 20 gg of Cd to pH --2, and shake it with portions of the dithizone solution in CC14 until the colour of the organic phase no longer changes. Discard the CC14 extracts. To the aqueous solution, add tartrate solution (the amount depending on the quantity of metals present), 0.5 ml of 1% HzDm solution in ethanol, and ammonia until neutral. Allow to stand for 1 min, then add 1 ml of hydroxylamine solution, and sufficient NaOH to give a minimum final NaOH concentration -- 5%. Extract the cadmium with portions of dithizone in CC14 (1 ml of 0.002% HzDz corresponds to 4.4 gg of Cd) until the extract is no longer pink. Wash the combined organic extracts with 0.1 M NaOH solution, and water. Dilute the solution with the solvent to the mark in a 25-ml standard flask, and measure its absorbance at 520 nm against CC14.
Note. When determining Cd in a solution containing a considerable excess of Zn, the two-stage extraction with KCN added should be used. After tartrate, hydroxylamine, and HzDm have been added to the sample solution, add NaOH and KCN solutions to give concentrations of-10% of the first and 0.2% of the second. Extract with CC14, and then strip the cadmium with 0.02 M HC1. To the aqueous back-extract, add a little tartrate, NHzOH, NaOH (to 10% concentration), and KCN (to 0.05% concentration). Re-extract with CC14, wash this extract with dilute NaOH and water, and measure its absorbance. 13.2.2.
5-Bromo-PADAP method
2-(5-Bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) (formula 4.3) forms with cadmium an intensely coloured complex in the pH range 9-11, which has been used for determination of cadmium [3,30-33]. The cadmium complex is formed immediately on mixing the reagents and is stable for at least 1 h. The molar excess of chromogenic reagent should be not less than threefold. The molar ratio Cd:reagent in the complex is 1:2. An increase in absorbance is observed when mixed (water-polar organic solvent) media are employed. In aqueous ethanol (50%, v/v), the molar absorptivity is 1.39.105 (a = 1.24) at 556 nm [3]. A similar sensitivity has been obtained in the presence of non-ionic surfactant polyglycol octyl phenyl ether [34]. Alternatively, the coloured complex can be extracted with isoamyl alcohol, CHC13, or benzene. The method is not very selective. A number of metals, such as Zn, Co, Ni, Mn, Cu, Pb, Fe interfere seriously. A preliminary separation of cadmium is usually necessary. A recommended highly selective separation is extraction of Cd as the iodide complex into mesityl oxide [2,3]. The best selectivity of extraction is obtained with --0.01 M KI and --0.1M H2804. In order to ensure a complete separation of interfering metals (e.g., Zn in analysis of zinc samples), the mesityl oxide extract must be washed by shaking with a dilute acidic aqueous solution of KI. The extractive separation of cadmium from iodide medium decreases the sensitivity of the method a little (e = 1.1-105).
Reagents 5-Br-PADAP, 0.02% (--7.10-4M) solution in ethanol. Standard cadmium solution: 1 mg/ml. Preparation as in Section 13.2.1. Ammonia buffer (pH -~10): 0.5 M solution with respect to ammonia and ammonium chloride.
136
13. Cadmium
Potassium iodide, 0.2 M (--3.3%) solution.
Procedure Extraction o f Cd as iodide. Shake a sample solution (-~20 ml, --0.1 M H2804, 0.01 M KI)
with 10 ml of mesityl oxide in a separating funnel for 30 s. Wash the extract by shaking (30 sec) with two 10-ml portions of 0.01 M KI solution in 0.1 M H2SO4. Determination of Cd. Re-extract Cd from the extract obtained above by shaking (30 s) with 5 ml of the ammonia buffer, and then with 5 ml of water. To these aqueous solutions (in a 25-ml standard flask) containing not more than 15 ~tg of Cd, add 10 ml of ethanol, 2 ml of 5-Br-PADAP solution, dilute with water to the mark, mix well, and measure the absorbance of the solution at 556 nm vs. a reagent blank solution.
13.2.3. Other Methods Apart from the method presented above involving 5-Br-PADAP, many other methods for cadmium determination are based on chelating azo dyes, such as PAN [35-39], PAR [4045] (formulas 4.1 and 4.2). The complex of Cd with PAN, in the presence of surfactants, has an absorptivity close to 5.104 [36]. The complex of Cd with PAR, in the presence of cetyldimethylbenzylammonium chloride, can be extracted into CHC13 (e = 9.8.104) [40]. Other surfactants also have been applied [43]. Among other pyridylazo reagents proposed for determining cadmium are: 2-(2-pyridylazo)-l-naphthol-4-sulphonic acid [46] and 2-(5chloro-2-pyridylazo)-5-dimethylaminophenol (~ = 1.2-105 at 550 nm) [47]. Cadion (p-nitrobenzenediazoaminobenzene-p-azobenzene) (formula 13.1) [48,49] is the basis of a very sensitive method for cadmium. In the presence of the non-ionic surfactant, Triton X-100, the absorptivity is 1.2.105 at 477 nm. Other azo reagents used are bromobenzothiazo (extraction into toluene, ~ = 5.8.104) [50] and Arsenazo III [51 ].
02
(13.1)
Numerous spectrophotometric methods are based on the formation of ion-associates of the anionic iodide complex (CdI42- or CdI3-) [52-55] and bromide (CdBr42-) [56] complexes with basic dyes. In the old flotation-spectrophotometric method (e = 1.3.105) [52], Crystal Violet is used, DIPE as floating solvent and acetone for dissolution of the floated compound. Other dyes that have been used in association with the cadmium iodide complex include Rhodamine 6G [57], Malachite Green (extraction with benzene) [53,54], and a basic azo dye [55]. The cationic complex of cadmium with 1,10-phenanthroline forms with acid dyes the ion associates which have become a basis for extraction-spectrophotometric methods of determining cadmium. Among the dyes used are: Rose Bengal (CHC13, e = 1.0.105) [58,59], Erythrosin (~ - 9.6-104) [60], dibromofluorescein [61], Bromophenol Blue (CHC13, ~ = 5.6.104) [62,63], and Thymol Blue [64]. The macrocycle, tetramethyltetra-azacyclotetradecane (4-Me-cyclam-14), gives selectively with Cd a cationic complex that can be extracted with the acid dye Erythrosin as counter-ion into CHC13 (~ = 1.1-105 at 550 nm) [65]. The cationic complex of cadmium with cryptand(2.2.1), associated with Erythrosin, has been also applied for determining Cd (nitrobenzene-toluene, ~ = 1.05.105) [66].
13.3. Analytical applications
137
The methods of determining cadmium with the use of porphyrins are very sensitive [e = (3-5)-105] [67,68]. Still higher sensitivity is obtained when derivative spectrophotometry techniques are applied [69]. An example of a porphyrin reagent is given by the formula (19.6). A number of other organic reagents have been applied in determining Cd. The triple complex of Cd with diphenylcarbazone and 1,10-phenanthroline is extractable into CHC13 or benzene (e = 9.4.104 at 536 nm) [70,71]. 1,10-Phenanthroline can be replaced by other organic bases [70]. Other reagents worthy of mention are 2,2'-diquinolyl-2quinolylhydrazone (e = 9.2.104 at 552 nm) [72], 2,2'-dipyridyl-bis(2-quinolylhydrazone) (in 80% ethanol, e = 5.1.10 4) [16], thio-HTTA [73], thiodibenzoylmethane [74], and 2pyridinediaminobenzene [75].
13.3. Analytical applications The dithizone method has been applied in determining cadmium in food products [12], natural waters [19], organic materials [76], zinc sulphide [23], beryllium [17], zirconium alloys [8], uranium compounds [77], Cd-Se and Cd-Te thin films [78]. The flow-injection technique (FIA) has also been applied in determining Cd with dithizone [79,80]. PAN has been used in determinations of Cd in environmental samples [81], industrial waste waters, renal stones, and metal alloys [38]. Cadmium has been determined with PAN by the FIA technique [82]. Cadion has been used in determining cadmium in industrial fluids (in zinc production) [20,83], and in soils [84]. The ion associate of cadmium iodide complex with Malachite Green has been used for determining Cd in fertilizers [85], and industrial fluids (in zinc production); with Crystal Violet for determining Cd in food products and in waste waters [86].
References 1. Gagliardi E., Ttimmler P., Talanta, 17, 93 (1970). 2. Rao T.P., Ramakrishna T.V., Talanta, 29, 227 (1982). 3. Jarosz M., Chem. Anal. (Warsaw), 31, 713 (1986). 4. McDonald C.W., Moore F.L.,Anal. Chem., 45, 983 (1973). 5. Kish P.P., Balog I.S., Zh. Anal. Khim., 31, 1306 (1976). 6. Marczenko Z., Mojski M., Krejzler J., J. Radioanal. Chem., 24, 9 (1975). 7. Watanabe H., Akatsuka K., Bull. Chem. Soc. Jpn., 41,620 (1968). 8. Ghersini G., Mariottini S., Talanta, 18, 442 (1971). 9. Grudpan K., Taylor C.G.,Analyst, 109, 585 (1984). 10. Nakamura K., Ozawa T., Anal. Chim. Acta, 86, 147 (1976). 11. Bajo S., Wyttenbach A., Anal. Chem., 49, 158 (1977). 12. Krylova A.N., Zhulenko V.N., Malyarova M.A., Zh. Anal. Khim., 51, 69 (1986). 13. Marczenko Z., Mojski M., Kasiura K., Zh. Anal. Khim., 22, 1805 (1967). 14. Sundar B.S. et al., Chem. Anal. (Warsaw), 36, 159 (1991). 15. Schweitzer G.K., Randalph D.R., Anal. Chim. Acta, 26, 567 (1962). 16. West K.J., Pflaum R.T., Talanta, 33, 807 (1986). 17. Hibbits J.O., Kallmann S., Oberthin H., Oberthin J., Talanta, 8, 104 (1961). 18. Strelow F.W., Louw W.J., Weinhert C.H., Anal. Chem., 40, 2021 (1968). 19. Korkisch J., Dimitriadis D., Talanta, 20, 1295 (1973).
138
13. Cadmium
20. Hayashibe Y., Sayama Y., Analyst, 121, 7 (1996). 21. Fritz J.S., Garralda B.B., Anal. Chem., 34, 102 (1962). 22. Akki S.B., Khopkar S.M., Z. Anal. Chem., 249, 228 (1970). 23. Kasiura K., Marczenko Z., Zh. Anal. Khim., 22, 1398 (1967). 24. Math K., Freiser H., Talanta, 21, 1215 (1974). 25. Wei-hua Yu., Freiser H.,Anal. Chem., 61, 1621 (1989). 26. Singh A.K., Ratnam B.K., Microchem. J., 39, 241 (1989). 27. Paradkar R.P., Williams R.R., Anal. Chem., 66, 2752 (1994). 28. Akaiwa H., Kawamoto H., Yoshimatsu E., Bull. Chem. Soc. Jpn., 52, 3718 (1979). 29. Akaiwa H., Kawamoto H., Yoshimatsu E., Anal. Sci., 1,297 (1985). 30. Shibata S., Kamata E., Nakashima R.,Anal. Chim. Acta, 82, 169 (1976). 31. Kubafi V., Macka M., Coll. Czech. Chem. Comm., 48, 52 (1983). 32. Nonova D., Stoyanov K., Mikrochim. Acta, 1984 I, 143. 33. Salim R., Shraydeh B., Microchem. J., 34, 251 (1986). 34. Sun Yi, Microchem. J., 36, 386 (1987). 35. Meus M., Rokosz A., Z. Anal. Chem., 303, 374 (1980). 36. Escriche J.M., Estelles M.L., Reig F.B., Talanta, 30, 915 (1983). 37. Rodionova T.V. et al., Zh. Anal. Khim., 44, 1053 (1989). 38. Nambiar D.C., Shinde V.M., Bull. Chem. Soc. Jpn., 68, 2277 (1995). 39. Koby~ecka J., Skiba E., Chem. Anal. (Warsaw), 38, 599 (1993). 40. Nonova D., Pavlova S.,Anal. Chim. Acta, 123, 289 (1981). 41. Tananayko M.M., Vysotskaya T.I., Ukr. Khim. Zh., 48, 629 (1982). 42. V16kova S. et al., Coll. Czech. Chem. Comm., 47, 1086 (1982). 43. Wen-bin Qi, Li-zhong Zhu, Talanta, 32, 1013 (1985). 44. Pilipenko A.T., Safronova V.G., Zakrevskaya L.V., Zh. Anal. Khim., 44, 1594 (1989). 45. Chakravarty S., Mishra R.K., Anal. Sci., 8, 609 (1992). 46. Jan6a~ L. et al., Coll. Czech. Chem. Comm., 4"7, 2654 (1982). 47. Villarreal M., Porta L., Marchevsky E., Olsina R., Talanta, 33, 375 (1986). 48. Watanabe H., Ohmori H., Talanta, 26, 959 (1979). 49. Hsu Chung-gin, Hu Chao-sheng, Jing Ji-hong, Talanta, 27, 676 (1980). 50. Yakovleva V.G., Ivanov Yu.M., Andrejchuk A.M., Zh. Anal. Khim., 31,884 (1976). 51. Michaylova V., Yuronkova L., Anal. Chim. Acta, 68, 73 (1974). 52. Courtot-Coupez J., Guerder P., Bull. Soc. Chim. France, 1961, 1942. 53. Kish P.P., Balog I.S., Zh. Anal. Khim., 32, 482 (1977); 34, 2326 (1979). 54. Garcia I.L., Navarro P., Cordoba M.H., Talanta, 35, 885 (1988). 55. Kish P.P., Balog I.S., Slivakov B.Ya., Zolotov Yu.A., Zh. Anal. Khim., 31, 1114 (1976). 56. Ishchenko N.N. et al., Zh. Anal. Khim., 45, 1557 (1990). 57. Kartikeyan S., Prasada R.T., Iyer C.S., Damodaran A.D., Talanta, 40, 771 (1993). 58. Tananayko M.M., Bilenko N.S., Zh. Anal. Khim., 30, 689 (1975). 59. Ishak C.F., Pflaum R.T.,Analyst, 113, 941 (1988). 60. Tananayko M.M., Bilenko N.S., Zh. Anal. Khim., 34, 1899 (1979). 61. Stolarov K.P., Firyulina V.V., Zh. Anal. Khim., 33, 2102 (1978). 62. Shestidesyatnaya N.L., Voronin O.G., Motyl V.A., Zh. Anal. Khim., 32, 260 (1977). 63. Buhl F., Mikula B., Chem. Anal. (Warsaw), 28, 779 (1983). 64. Mathew L., Rao T.P., Iyer C.S., Damodaran A.D., Mikrochim. Acta, 111,231 (1993). 65. Szczepaniak W., Juskowiak B., Ciszewska W., Anal. Chim. Acta, 156, 235 (1984). 66. Szczepaniak W., Juskowiak B., Chem. Anal. (Warsaw), 32, 121 (1987). 67. Komata M., Itoh J., Talanta, 35, 723 (1988). 68. Kawamura K., Igorashi S., Yotsuyanagi T.,Anal. Sci., 4, 175 (1988).
References
69. Ishii H., Satoh K., Satoh Y., Koh H., Talanta, 29, 545 (1982). 70. Yamada E. et al., Anal. Chim. Acta, 138, 409 (1982). 71. Yamada E. et al., Bull. Chem. Soc. Jpn., 55, 3151 (1982). 72. Otomo M., Singh R.B., Anal. Sci., 1, 165 (1985). 73. Solanke K.R., Khopkar S.M., Sep. Sci., 8, 511 (1973). 74. Schuknecht B., R6bisch G., Uhlemann E., Anal. Chim. Acta, 69, 329 (1974). 75. Zhu Y.R. et al., Analyst, 120, 2853 (1995). 76. Analytical Methods Committee, Analyst, 94, 1153 (1969). 77. Korkisch J., Dimitriadis D., Mikrochim. Acta, 1974, 449. 78. Marczenko Z., Mojski M., Czarnecka I., Chem. Anal. (Warsaw), 18, 189 (1973). 79. Klinghoffer O., Ru2i6ka J., Hansen E.H., Talanta, 27, 169 (1980). 80. Burguera J.L., Burguera M., Anal. Chim. Acta, 153, 207 (1983). 81. Raman B., Shinde V.M.,Analyst, 115, 93 (1990). 82. Facchin I., Pasquini C., Anal. Chim. Acta, 308, 231 (1995). 83. Hayashibe Y., Sayama Y., Oguma K., Fresenius'J. Anal. Chem., 355, 144 (1996). 84. Qiu X., Zhu Y., Yan J.,Analyst, 113, 1329 (1988). 85. Gomez Neto J.A. et al.,Anal. Chim. Acta, 308, 439 (1995). 86. Hu J., Qu W.B., Pu B.Y., Mikrochim. Acta, 109, 295 (1992).
139
Chapter 14. Calcium Calcium (Ca, at. mass 40.08) occurs in compounds in the II oxidation state. The hydroxide, Ca(OH)2 (solubility 1.3 g/1.), is a strong base. Calcium ions form sparingly soluble compounds with oxalate and carbonate, and also form weak complexes with EDTA and tartrate.
14.1. Methods of separation 14.1.1. Precipitation A preliminary separation of the Analytical Group I-II metals, which interfere, is often accomplished by precipitation of their sulphides, hydroxides (pH --9), or compounds with oxine or DDTC. Precipitation with oxalate at pH 3-4 separates calcium from metals which give soluble oxalate complexes [e.g., Fe(HI), A1, and Ti], and also from phosphate. Calcium oxalate can also be precipitated from homogenous solution [ 1]. Traces of Ca and Mg are separated from matrices of metals forming cyanide complexes (e.g., Ni, Zn, and Mn) by precipitation as phosphate with a lanthanum collector in an alkaline cyanide medium [2]. Small amounts of Ca can be separated from Mg by co-precipitation with strontium sulphate from aqueous ethanol [3]. Fe(III), Cr, Mn, and phosphate were separated from Ca and Mg by precipitating with a suspension of PbCO3 [4].
14.1.2. Extraction. Ion exchange Calcium has been extracted (Sr and Ba are not extractable) with a mixture of CC14 and TBP ( 1 0 - 2 0 % ) from alkaline medium (0.1-1 M NaOH) as a complex with Azo-azoxy BN (formula 14.1) [5]. 0
OH
(14.1) CH3
During the extraction, the colour of the CC14-TBP phase changes from the orange-red of the Azo-azoxy BN to the red of the calcium Azo-azoxy BN complex. Calcium is stripped from the organic phase with water or dilute HC1. After this stripping, the CC14 solution of Azoazoxy BN may be reused.
14.2. Methods of determination
141
A reagent BT (related to Azo-azoxy BN) has been suggested as an extractant for Ca, Sr, and Mg. The BT reagent is used in cyclohexane-TBP (1 + 1) solution. Calcium can be extracted at lower pH than with Azo-azoxy BN [6]. Calcium can also be separated by extraction of its complexes with HTTA (CC14) [7], di(2-ethylhexyl) dithiophosphate (hexane) [8], and BPHA (CHC13) [9]. Calcium, Sr, and Ba can be extracted as crown-ether complexes [10,11], which enable one to separate those elements [12,13]. Ca (and Sr) was also extracted with pyrazolone derivatives and with trioctylphosphine oxide (cyclohexane) [14]. Calcium can be extracted with Cryptand 2.2.2 using Erythrosin as the counter-anion [14a]. Calcium is often separated from Mg, Sr, Ba, and other metals by cation-exchange chromatography in the presence of EDTA [15,16], EGTA [16,17], chloride [18], and malonate [19]. Calcium has been sorbed on cation-exchange resins with carboxylic groups [20]. Calcium has been separated from a number of metals in HCl-methanol medium [21 ]. Ca and Sr mixtures have been separated on anion-exchange resin from methanol-HNO3 medium [22].
14.2. Methods of determination Glyoxal bis(2-hydroxyanil) is often used for the determination of calcium either in aqueous media or after extraction. A sensitive method involving the Chlorophosphonazo III has been described.
14.2.1 Glyoxal bis(2-hydroxyanil) method Glyoxal bis(2-hydroxyanil) (GBHA, formula 14.2) forms a sparingly soluble red complex with calcium in alkaline media. The compound dissolves in aqueous methanol (1 + 1) media by the substitution of two molecules of methanol for the two water molecules coordinatively bonded to the calcium.
N~C--C~N.~~ OH OH
~,,s/c-c~~
(14.2)
'o. "'c~ o '
The methanol solution of GBHA is colourless. As sodium hydroxide is added and the hydroxyl groups dissociate, the solution becomes more and more intensely yellow. The optimum alkalinity of the solution G-0.04 M NaOH) is that at which the reaction of GBHA with calcium is complete, but the colour of the reagent is still weak. The absorption maximum of the red-violet complex is at 516 nm. The molar absorptivity of the compound e - 1.8.104 (specific absorptivity 0.45). The absorbance of the solution should be measured within 10 min of the development of the colour, otherwise a slow fading of the colour will be observed (2-3% in 30 min). GBHA reacts with a number of metals other than calcium (e.g., barium and strontium). Magnesium and the alkali metals do not interfere. The Analytical Group I-III metals interfere and should be separated. Small quantities may be masked by adding a little KCN and NazS [and some NH2OH when Fe(III) is present]. To prevent the reaction of GBHA with Ba and Sr, a small amount of sulphate or carbonate is added to the sample solution. Phosphate, fluoride, oxalate, tartrate, citrate, and EDTA interfere in the reaction of calcium with GBHA.
142
14. Calcium
When the red complex of calcium with GBHA is extracted with 1,2-dichloroethane in the presence of Zephiramine, the absorbance of the extract remains unchanged for 6 h [26]. Before the determination with G B H A , calcium may be extracted with a 0.01% solution of Azo-azoxy BN in CC14 (containing 20% TBP), and then stripped into dilute hydrochloric acid.
Reagents Glyoxal bis(2-hydroxyanil) (GBHA), 0.05% solution in methanol. Solutions more than a week old must be discarded. Standard calcium solution: 1 mg/ml. Dissolve 2.4980 g of CaCO3, dried at 110~ in 40 ml of 2 M HC1. Remove CO2 by boiling, and dilute the solution with water in a volumetric flask to 1 litre. Azo-azoxy BN, 0.01% solution. Dissolve 12 mg of reagent in 100 ml of CC14. Add 2 ml of TBP to 10 ml of the CC14solution before it is used for the extraction.
Procedure Extraction of Ca with Azo-azoxy BN. Add sufficient 5M NaOH to the sample solution to make the NaOH concentration 0.5-1 M. Shake the solution for 1 min with the solution of Azo-azoxy BN. Strip calcium from the extract with a small volume of 1M hydrochloric acid. Determination of Ca. The sample solution should contain not more than 30 ~tg of Ca, and be free from ammonium salts and Analytical Group I-III metals (to mask small amounts of these metals, add -10 mg each of KCN and NazS. Neutralize the sample solution (to pH 7-8) with NaOH or HC1, and add -20 mg of NazSO4. Add 12 ml of the GBHA solution and 1 ml of 1 M NaOH, and dilute the solution with water to the mark in a 25-ml standard flask. After 10 min, measure the absorbance of the solution at 516 nm against a blank solution.
Note. If the Ca is first extracted by the Azo-azoxy BN method, neutralize the acidic backextract, add the GBHA solution, and proceed as described above.
14.2.2. Chlorophosphonazo I l l method The colour reaction of Chlorophosphonazo HI (formula 4.11) with calcium ions gives a sensitive spectrophotometric method for calcium [28-30]. The determination may be carried out either in weakly acid solution (pH 2-3) ( ~ = 2.8.104) or in a neutral medium (pH ~-7). In this case the molar absorptivity is 5.4.104 at 668 nm ( a = 1.3) [30]. The absorbance maximum of the reagent in neutral medium is at 570 nm. Analytical Group I-III metals interfere, and, in principle, they should be separated. Microgram amounts of some of them can be masked with EDTA [29]. Magnesium scarcely reacts with Chlorophosphonazo III in acidic media, so calcium can be determined in the presence of a 10-fold amount of magnesium [29]. At about pH 7, magnesium does react with Chlorophosphonazo III. Strontium and barium ions give colour reactions over a wide pH range. Preliminary separation of calcium from Mg, Sr and Ba is possible by extraction with Azo-azoxy BN. The concentration of alkali metal and ammonium salts influences the colour reaction; the absorbance decreases as ionic strength increases. Thus the concentrations of salts, as well as the pH, should be matched in sample- and standard solutions. Phosphate and borate buffers are recommended.
14.2. Methods of determination
143
Reagents Chlorophosphonazo III, 0.03% solution. Standard calcium solution: 1 mg/ml. Preparation as in Section 14.2.1. Buffer solution, pH 7.5. Mix 50 ml of 0.1 M KHzPO4 solution with 41 ml of 0.1 M NaOH, and dilute with water to 100 ml.
Procedure To the sample solution containing not more than 15 gg of Ca, add 2.5 ml of Chlorophosphonazo III solution, and water to -~20 ml. Neutralize with ammonia to pH about 7, and add 1 ml of buffer solution. Transfer the solution to a 25-ml standard flask, dilute to volume with water, and mix well. After 15 min, measure the absorbance of the solution at 668 nm vs. a blank solution. Note. The sample solution should not contain Analytical Group I-III metals. Trace amounts can be masked by adding one drop of 1% Na2S solution. The Azo-azoxy BN method is convenient for separation of Ca from Mg, Sr and Ba (Section 14.2.1).
14.2.3. Other M e t h o d s
HO~S~.O3H
Calcichrome (identical with Calcion, formula 14.3) has been proposed as a highly selective, stable reagent for calcium [32-36]. The molar absorptivity is 7.6.103 at 615 nm.
OH
N,,,,N
OH
(14.3)
Many azo reagents have been recommended for determining calcium, e . g . , Arsenazo III (e = 4.4.104 at 650 nm) [37-41], PAR [42,43], Eriochrome Black T [44,45], Carboxynitrazo [46], Hydroxynaphthol Blue [47], and 2-(8-hydroxy-2-quinolylazo)-l-naphthol [48]. Various organic reagents are used for direct determination of calcium, such as murexide (ammonium purpurate) (E = 1.4.104 at 500 nm) [2,49], Metalphthalein [50], Calcein [51,52], Chrome Azurol S (in the presence of 1,10-phenanthroline) [53], Alizarin S [54], 8hydroxyquinoline (extraction into CHC13 in the presence of n-butylamine or butoxyethanol) [55], and Emodine (1,3,8-trihydroxy-6-methylanthraquinone) [56]. Calcium has been determined as a complex with Emodine, in the presence of Be and Mg, by the derivative spectrophotometry technique. The anionic complexes of calcium with bromo-oxine [57] or HTTA [58] have been extracted into benzene as ion associates with Rhodamine B. Calcium was also determined as a complex with o-cresolphthalein [59-63], or thymolphthalein [64]. A very sensitive method for determining calcium is based on the complex of Ca with the chromogenic macrocyclic reagent (formula 14.4) (1,2-dichloroethane, E - 5.5.104 at 406 nm) [65]. Other diaza-crown ethers have been also used in determinations of Ca (and Mg) [66]. Calcium has been determined after extraction (CHC13 + benzene) with the crown ether and association with Propyl Orange [67].
144
14. Calcium
"
_Oo .D z
NO
"i (_0 o3
CH z
(14.4)
14.3. Analytical applications The methods involving GBHA have been applied for determining calcium in milk [68], soil, plant material, and natural waters [69], uranium [70], silicate minerals [71], and lithium and barium salts [27]. Chlorophenazo III has been used for determination of calcium in waters [29,30,72-74], snow [74], soil [75], steel [76], molybdenum alloys [77], cobalt [78], aluminium alloys [79], and boric acid [29]. The flow injection technique has also been applied [73,80]. Calcichrome has been used for determination of calcium in soil extracts [81] and in poly(ethylene terephthalate) [82]. Calcium has been determined in fiver water with Propyl Orange after extraction with a crown ether [67]. Arsenazo III has been used for determination of Ca in blood serum [83] and in urea [40]. Calcium has been determined with PAR in waters [42,43,84], and with Eriochrome Black in soil extracts and rocks [45]. Calcium has been determined with o-cresolphthalein in proteins [59], waters [60-62], and soil extracts [62]. The flow-injection technique has been applied [60,62]. Thymolphthalein has been used for determining Ca in blood serum [64]. Calcium has been determined with metalphthalein in water, urea, and pharmaceutical samples [50].
References 1. Grzeskowiak R., Turner T.A., Talanta, 20, 35 (1973). 2. Marczenko Z., Kasiura K., Chem. Anal. (Warsaw), 7, 775 (1962). 3. Kar K.R., Singh G.,Anal. Chim. Acta, 35, 259 (1966). 4. Bezuglyi D.V. et. al., Zh. Anal. Khim., 26, 1010 (1971). 5. Gorbenko F.P., Sachko V.V., Zh. Anal. Khim., 18, 1198 (1963); 24, 15 (1969); 25, 1884 1970). 6. Gorbenko F.P., Nadezhda A.A., Vozdvizhenskaya S.A., Zh. Anal. Khim., 31, 1898 (1976). 7. Sekine T., Dyrssen D., Anal. Chim. Acta, 37, 217 (1967). 8. Shatskaya S.S., Samoilov Yu. M., Zh. Anal. Khim., 42, 272 (1987). 9. Minczewski J., Chwastowska J., R62afiska B., Chem. Anal. (Warsaw), 19, 497 (1974). 10. Strzelbicki J., Bartsch R.A., Anal. Chem., $3, 2247 (1981). 11. Maeda T., Kimura K., Shono T., Z. Anal. Chem., 313, 407 (1982). 12. Mohite B.S., Khopkar S.M., Analyst, 112, 191 (1987). 13. Katayama Y. et al.,Anal. Chim. Acta, 204, 113 (1988). 14. Sasaki T., Umetani S., Matsui M., Tsurubou S., Chem. Lett., 7, 1195 (1994). 14a. Ajgaonkar H.S., Khopkar S.M., Chem. Anal. (Warsaw), 44, 61 (1999). 15. Chwastowska J., Szymczak S., Chem. Anal. (Warsaw), 14, 1161 (1969). 16. Strelow F.W., Weinert C.H., Talanta, 17, 1 (1970). 17. Povondra P., Pfibil R., Talanta, 10, 713 (1963).
References 18. Strelow F.W., Van Zyl C.R., Anal. Chim. Acta, 41,529 (1968). 19. Strelow F.W., Van Zyl C.R., Nolte C.R.,Anal. Chim. Acta, 40, 145 (1968). 20. Pesavento M., Biesuz R., Cortina J.L., Anal. Chim. Acta, 298, 225 (1994). 21. Strelow F.W., Anal. Chim. Acta, 127, 63 (1981). 22. Grahek Z. et al., J. Radioanal. Nucl. Chem., 182, 401 (1994). 23. Umland F., Meckenstock K.U., Z. Anal. Chem., 176, 96 (1960). 24. Lindstrom F., Milligan C.W., Anal. Chem., 39, 132 (1967). 25. Kuczerpa A.V.,Anal. Chem., 40, 581 (1968). 26. Nishimura M., Noriki S., Muramoto S., Anal. Chim. Acta, 70, 121 (1974). 27. Gorbenko F.P., Sachko V.V., Zh. Anal. Khim., 18, 1497 (1963); 20, 309 (1965). 28. Ferguson J.W. et al., Anal. Chem., 36, 796 (1964). 29. Lukin A.M., Smirnova K.A., Vysokova N.N., Zavod. Lab., 34, 1436 (1968). 30. Marczenko Z., Ka~owska H., Chem. Anal. (Warsaw), 21, 183 (1976). 31. Novikov E.A., Shpigun L.K., Zh. Anal. Khim., 48, 1326 (1993). 32. West T.S., Analyst, 87, 630 (1962). 33. Close R.A., West T.S., Talanta, 5, 221 (1960). 34. Herrero-Lancina M., West T.S.,Anal. Chem., 35, 2131 (1963). 35. Mendes-Bezerka A.E., Stephen W.I., Analyst, 94, 1117 (1969). 36. Chau L.K., Pruski M., Porter M.D., Anal. Chim. Acta, 217, 31 (1989). 37. Michailova V., Ilkova P., Anal. Chim. Acta, 53, 194 (1971). 38. Michailova V., Kouleva N., Talanta, 21,523 (1974). 39. Morgan B., Artiss J., Zak B., Microchem. J., 44, 15 (1991). 40. Kratochvil B., He X., Can. J. Chem., 68, 1932 (1990). 41. Blanco M. et al., Anal. Chim. Acta, 224, 23 (1989). 42. Gomez E., Estela J.M., Cerda V., Anal. Chim. Acta, 12, 513 (1991). 43. Hernandez O. et al.,Anal. Chim. Acta, 320, 177 (1996). 44. Haj-Hussein A.T., Christian G.D., Microchem. J., 34, 67 (1986). 45. Zolotov Yu.A. et al., Anal. Chim. Acta, 308, 386 (1995). 46. Petrova T.V., Savvin S.B., Dzherayan T.G., Zh. Anal. Khim., 30, 918 (1975). 47. Brittain H.G., Anal. Chem., 49, 969 (1977); Anal. Chim. Acta, 96, 165 (1978). 48. Ishizuki T. et al.,Anal. Chim. Acta, 176, 63 (1985). 49. Gordon H., Norwitz G., Talanta, 19, 7 (1972). 50. Van Staden J.F., Taljaard R.E., Anal. Chim. Acta, 323, 75 (1996). 51. Robinson C., Weatherell J.A., Analyst, 93, 722 (1968). 52. Chimpalee N. et at., Anal. Chim. Acta, 271, 247 (1993). 53. Ganago L., Alinovska L.A., Zh. Anal. Khim., 43, 1972 (1988). 54. Khalifa M.E., Chem. Anal. (Warsaw), 41, 357 (1996). 55. Luke C.L., Anal. Chim. Acta, 32, 221 (1965). 56. Pal T., Jana N.R.,Analyst, 118, 1337 (1993). 57. Bel'tyukova S.V., Poluektov N.S., Zh. Anal. Khim., 25, 1714 (1970). 58. Poluektov N.S., Bel'tyukova S.V., Zh. Anal. Khim., 25, 2106 (1970). 59. Phillipou G., Raniolo E., Clin. Chem., 36, 1385 (1990). 60. Yamane T., Goto E., Talanta, 38, 139 (1991). 61. Nyman J., Ivaska A., Anal. Chim. Acta, 308, 286 (1995). 62. Nogueira A.R., Brienza S.M., Zagatto E.A., Lima J.L., J. Agric. Food Chem., 44, 165 (1996). 63. Van Staden J.F., Malan D., Talanta, 43, 881 (1996). 64. Kruchkova E.S., Pukhova V.M., Maistrenko V.N., Zh. Anal. Khim., 44, 2265 (1989). 65. Nishida H. et al., Mikrochim. Acta, 1981 I, 281.
145
146
14. Calcium
66. Blair T.L., Desai J., Bachas L.G., Anal. Lett., 25, 1823 (1992). 67. Motomizu S., Oshima M., Yoneda N., Iwachido T.,Anal. Sci., 6, 215 (1990). 68. Nickerson T.A., Moore E.E., Zimmer A.A., Anal. Chem., 36, 1676 (1964). 69. Jacintho A.O. et al.,Anal. Chim. Acta, 130, 361 (1981). 70. Abrao A., Anal. Chem., 37, 437 (1965). 71. King H.G., Pruden G., Analyst, 94, 39 (1969). 72. Zenki M., Anal. Chem., 53, 968 (1981). 73. Yuan Y.,Anal. Chim. Acta, 212, 291 (1988). 74. Zenki M., Ohmuro K., T6ei K., Fresenius'J. Anal. Chem., 338, 707 (1990). 75. Qiu X.C., Zhang Y.S., Zhu Y.Q.,Analusis, 12, 273 (1984). 76. Yakovlev P. Ya., Zhukova M.P., Zavod. Lab., 36, 1169 (1970); 37, 1292 (1971). 77. Zhukova M.P., Shemyakin F.M., Yakovlev P.Ya., Zh. Anal. Khim., 28, 1705 (1973). 78. Zhukova M.P., Yakovlev P.Ya., Zavod. Lab., 39, 661 (1973). 79. Zhukova M.P., Matrosova T.V., Yakovlev P.Ya., Zh. Anal. Khim., 26, 2231 (1971). 80. Yuan Y., Anal. Chim. Acta, 212, 291 (1988). 81. Pakalns P., Florence T.M., Anal. Chim. Acta, 30, 353 (1964). 82. Borshch N.A., Mal'tseva N.G., Ivanova I.V., Zavod. Lab., 47, No 4, 12 (1981). 83. Morgan B.R., Artiss J.D., Zak B., Clin. Chem., 39, 1608 (1993). 84. Gomez E. et al., Analyst, 120, 1181 (1995).
Chapter 15. Carbon Carbon (C, at. mass 12.01) occurs in compounds principally in the IV oxidation state. Carbonate (CO32-) gives sparingly soluble salts with all cations except Group I metals and the ammonium ion, as well as soluble complexes with U and Th ions. Of the carbon compounds generally considered inorganic, the cyanides (CN-) and thiocyanates (SCN-) are of great importance in analysis. The analytical reactions of cyanide and thiocyanate are similar to those of the halogens. Cyanide gives stable complexes with such metals as Hg(II), Ag, Cu(I), Fe(II and III), Ni, and Co(HI). Coloured thiocyanate complexes [e.g. with Fe(III), Co, Mo, Ti, Re, and Nb] are of major importance in spectrophotometric analysis.
15.1. Separation of cyanide Since cyanides are very poisonous, suitable precautions should be taken during their separation and determination. Hydrogen cyanide is such a weak acid that it volatilises from cyanide solutions at pH < 9. Usually HCN is separated by distillation from solutions acidified with tartaric acid to pH --3. Nitrogen or air is passed through the heated solutions to accelerate the separation of HCN. HCN is absorbed in dilute NaOH or NazCO3 solutions [1-3]. Any sulphide present in the sample solution is precipitated with Zn or Cd ions before the distillation of HCN. Complex cyanides are precipitated with zinc ions if it is necessary to separate HCN derived only from simple cyanides (e.g., KCN). To determine total cyanides in solutions containing both simple cyanides and metal cyanide complexes, more drastic conditions are necessary to decompose the complexes, before the HCN is distilled off. Decomposition of complex cyanides occurs on heating with non-volatile mineral acids (H2SO4, H3PO4) in the presence of, e.g., EDTA or tartaric acid [4]. The cyanide complexes of Zn, Cd, Ni, and Fe(III) are decomposed fairly rapidly. On the other hand, Co(HI), Fe(II), Cu, Hg, and Pd complexes are decomposed only with difficulty. Decomposition of this latter group requires a long heating. The cyanide complexes of Fe(II), Fe(III), Ni and Zn can be decomposed by grinding them with sulphur and KC1, then heating at 300~ The thiocyanate formed is then determined as the Fe(III) complex [5]. Cyanide, complex cyanides, cyanate, and ammonia have been separated by selective steam distillation at various pH values [6]. Traces of hydrogen cyanide have been separated conveniently by the microdiffusion method (also referred to as isothermal distillation) [7]. Cyanide has been preconcentrated from water by extraction with tributyltin hydroxide in trichloroethylene [8].
15.2. Determination of cyanide The most important spectrophotometric methods for determining cyanide are based on the formation of polymethine dyes. These methods are highly sensitive and specific. The benzidine-pyridine method is often used. Lower colour stability is a drawback of the pyrazolone method. The barbituric acid method can also be recommended.
148
15. Carbon
15.2.1. Benzidine-pyridine method In this method, cyanide reacts with bromine water to form cyanogen bromide, CNBr, which then reacts with pyridine to yield glutaconic aldehyde. This aldehyde is condensed with an aromatic amine (benzidine) to form a red polymethine dye, which is the basis for determination of cyanide. The excess of bromine is reduced with As(III). The colour intensity reaches a maximum after 15 min, and remains constant for a further 30 min. The method is highly sensitive. The molar absorptivity (with respect to CN-) at ) g m a x -530 nm is about 6.0.10 4 ( a - 2.3). The colour obtained depends on the reaction conditions [9,10]. When the sample solution is turbid or is itself coloured, the reaction product may be extracted into butanol. Any thiocyanate present in the sample solution also reacts with bromine to form cyanogen bromide. Since thiocyanate is non-volatile, cyanide can be conveniently separated by distillation as HCN. The use of p-phenylenediamine has been recommended instead of benzidine, which is an active carcinogen. The molar absorptivity, e = 3.1.104 [11 ]. The glutaconic aldehyde formed in the reaction of cyanogen bromide with pyridine has been condensed with anthranilic acid [ 12]. In the determination of cyanide, use has also been made of the polymethine dye which is formed in the reaction of cyanogen chloride with pyridine and barbituric acid. Chloramine T has been used for the chlorination of cyanide. This highly sensitive method (e = 1.0.105 at 580 nm) has been studied in detail [13-16]. 4-Methylpyridine has been suggested instead of pyridine [17]. In another method for determining cyanide, cyanogen chloride (obtained by the action of Chloramine T) reacts with a pyridine-pyrazolone reagent to form a blue dye 0~max = 630 nm) [18,19].
Reagents Benzidine hydrochloride, 1% solution. Add 0.5 g of the reagent to 50 ml of 0.5 M HC1, heat to boiling, cool, and filter. Keep the filtrate in an amber-glass bottle. Benzidine-pyridine reagent. Mix 18 ml of redistilled pyridine, 12 ml of water, and 3 ml of conc. HC1. Add 10 ml of the benzidine solution, and shake until a clear solution is obtained. Prepare this solution fresh daily. Standard cyanide solution, 1 mg/ml. Dissolve 0.2503 g of KCN in cold water which has been previously boiled, and dilute the solution with similar water to volume in a 100-ml standard flask. Store the solution in a polyethylene bottle. This solution is unstable.
Procedure Place the alkaline solution (about 10 ml) containing not more than 10 ~tg of CN- in a 25-ml standard flask. Acidify the solution with glacial acetic acid and add 1 ml in excess. Immediately add 1 ml of bromine water. Mix the solution thoroughly, and let it stand for 10 min with occasional shaking. Add a 1.5% solution of sodium arsenite dropwise to reduce the excess of bromine, then 2-3 drops more. Add 5 ml of the benzidine-pyridine reagent, and stir the solution. After 30 sec, add 5 ml of ethanol, make up to the mark with water, and stir well. After 15 min, measure the absorbance of the solution at 530 nm against a reagent blank.
15.2 Methods of determination
149
15.2.2. Other methods In an extractive spectrophotometric method for determining cyanide, a coloured ion-pair formed between cyanide complex of Fe(II) and bathophenanthroline is extracted into chloroform [20]. Several indirect methods for determination of cyanide involve the displacement by cyanide of metals from their complexes with organic reagents, with subsequent change in colour of the solutions, such as the methods using Hg(II) complexes with diphenylcarbazone [21 ] and Methylthymol Blue [22]. The cyanide ion can displace Ag from its associates with phen and Bromopyrogallol Red [23], and eosin [24]. Cyanide ions liberate coloured ferroin from the solid [Fe(phen)32+][I3-]2. A method based on displacement of IO3- from the sparingly soluble Pb(IO3)2, with subsequent reaction of the IO3- with iodide added, and determining the liberated I2 as the coloured starch complex has also been proposed [26]. Cyanide enhances the redox potential of copper(II). Spectrophotometric methods for determining cyanide based on this property involve oxidation of phenolphthalein [27]. Phenolphthalein has been used in determining cyanide by the flow injection technique [27].
15.2.3. Analytical applications The benzidine-pyridine method has been used mostly for determining cyanide in waters and sewage [9,28]. The p-phenylenediamine method has been applied for determining cyanide in water and sewage [7,29-31] and in fodder [32]. The barbituric acid method was used for determining cyanide in sewage [33]. Cyanide was also determined by this method in industrial waste-water using the FIA technique [34]. The pyridine-pyrazolone method has been used in the determinations of cyanide in water [18], sewage [18,19], blood [35], free cyanide in ferro- and ferricyanides [36] and in cyanide complexes of Pt and Pd, after decomposition of the complexes [37].
15.3. Separation and determination of other carbon compounds Thiocyanate is separated from cyanide by distilling off HCN from a weakly acid medium. With bromine and chloramine-T, thiocyanate is converted into cyanogen bromide and cyanogen chloride, respectively, and determined as a polymethine dye by the benzidinepyridine method or pyridine-barbituric acid method [38-40]. The latter method has been applied for continuous determination of thiocyanate in blood plasma and in urine [40]. In the absence of cyanide, thiocyanate can be determined as the thiocyanate complex FeSCN 2+, formed in acid medium with excess of Fe(III) [41 ]. Thiocyanate may be extracted and determined as the ion-association complexes formed by SCN- with Methylene Blue (1,2dichloroethane) [42], Rhodamine B (benzene) [43], and ferroin (nitrobenzene) (44). In an indirect method, thiocyanate and Hg(II) form a mixed-ligand mercury complex with quinoline, which can be extracted into chloroform. This complex can be treated with a CHC13 solution of dithizone to form the Hg(HDz)2 complex [45]. Ferrocyanide [hexacyanoferrate(II), Fe(CN)64-] can be determined as the Prussian Blue formed by addition of Fe(III) in hydrochloric acid solution [46]. The Prussian Blue is extractable into chloroform in the presence of dimethyl-lauryl-benzylammonium bromide [47]. Ferrocyanide decomposes, with liberation of HCN, on heating with tartaric acid and
150
15. Carbon
EDTA. The hydrogen cyanide is distilled off and determined by the barbituric acid method. Ferrieyanide [hexacyanoferrate(III), Fe(CN)63-] can be determined using its oxidising properties, e.g., by the oxidation of 5-sulphobutylamide-2'-methoxyphenylanthranilic acid in 4 M NaOH medium [48]. Ferricyanide has been separated from ferrocyanide by extraction (butanol, amyl alcohol), associated with triphenyl-n-propylphosphonium ion. The absorbance of the extract has been measured at 420 nm [49]. Carbon monoxide can be determined by reduction of silver in alkaline solutions of Ag p-sulphanoylbenzoate and measuring the absorbance of the coloured Ag sol obtained [5052]. The method has been used for determining CO in air and in blood. Carbon monoxide has also been determined (in the presence of NO, SO2, and CO2) by reduction of Ag(I) from its salt with sulphanilic acid [53]. The reduction of Pd(II) by CO followed by reaction with KIO3 to form ICln- ions which form ion-pairs with Pyrronine Y (extraction with benzene) has also been used for determination of CO [54]. The yellow cacotheline is reduced to the violet dihydroxycacotheline by Pd formed in the reduction of PdC142- complex by CO [55]. Carbon dioxide is determined in gas mixtures on the basis of its acidic properties, e.g., by passing the gas through a solution of NaHCO3 in the presence of a pH indicator such as Phenol Red or phenolphthalein [56,57]. Carbon traces in titanium, zirconium, and other metals have been determined by oxidising the sample with a mixture of PbCrO4 and V205 at 1,200 ~ and absorption of the CO2 evolved in an alkaline solution of Thymol Blue [58].
References 1. Willekens G.J., Van Den Bulcke A.,Analyst, 104, 525 (1979). 2. Zhu Y.R., Wei F.S., You F., Talanta, 30, 795 (1983). 3. Blanco M., Maspoch S., Talanta, 31, 85 (1984). 4. Leschber R., Schlichting H., Z. Anal. Chem., 245, 300 (1969). 5. Tobia S.K., Gawargious Y.A., E1-Shahat M.F., Analyst, 99, 544 (1974). 6. Hilbert F., Darwish N.A., Z. Anal. Chem., 255, 357 (1971). 7. Hangos-Mahr M., Pungor E., Kuznetsov V.,Anal. Chim. Acta, 178, 289 (1985). 8. Wroflski M., Talanta, 28, 255 (1981). 9. Higson H.G., Bark L.S., Analyst, 89, 338 (1964). 10. Kaur P., Upadhyay S., Gupta V.K.,Analyst, 112, 1681 (1987). 11. Bailey P.L., Bishop E., Analyst, 97, 691 (1972). 12. Upadhyay S., Gupta V.K.,Analyst, 109, 1619 (1984). 13. Lambert J.L., Ramasamy J., Paukstelis J.V., Anal. Chem., 47, 916 (1975). 14. Nagashima S.,Anal. Chim. Acta, 99, 197 (1978). 15. Broderius S.J., Anal. Chem., 53, 1472 (1981). 16. Csikai N.J., Barnard A.J. Jr.,Anal. Chem., 55, 1677 (1983). 17. Nagashima S., Anal. Chim. Acta, 91, 303 (1977). 18. Goulden P.D., Afghan B.K., Brooksbank P., Anal. Chem., 44, 1845 (1972). 19. Nagashima S., Anal. Chem., 55, 2086 (1983). 20. Mariaud M., Levillain P., Talanta, 34, 535 (1987). 21. Okutani T., Utsumi S., J. Chem. Soc. Jpn., Pure Chem. Sect., 87, 444 (1966). 22. Nomura T., Bull. Chem. Soc. Jpn., 41, 1619 (1068). 23. Dagnall R.M., E1-Ghamry M.T., West T.S., Talanta, 15, 107 (1968). 24. Buhl F., Kania K., Chem. Anal. (Warsaw), 24, 689 (1979). 25. Lambert J.L., Manzo D.J., Anal. Chem., 40, 1354 (1968). 26. Verma K.K., Tyagi P., Ekka M.G., Talanta, 33, 1009 (1986). 27. Haj-Hussein A.T., Talanta, 44, 545 (1997).
References 28. Royer J.L., Twichell J.E., Muir S.M.,Anal. Lett., 6, 619 (1973). 29. Montgomery H.A., Gardiner D.K., Gregory J.G., Analyst, 94, 284 (1969). 30. Casapieri P., Scott R., Simpson E.A., Anal. Chim. Acta, 49, 188 (1970). 31. Botto R.I., Karchmer J.H., Eastwood M.W., Anal. Chem., 53, 2375 (1981). 32. Harris J.R., Morson E.H., Hardy M.J., Curtis D.J., Analyst, 105, 974 (1980). 33. Drikas M., Routlej B.I.,Analyst, 113, 1273 (1988). 34. Rios A., Luque de Castro M.D., Valcarce! M., Talanta, 31, 673 (1984). 35. Baar S.,Analyst, 91, 268 (1966). 36. Kruse J.M., Thibault L.E.,Anal. Chem., 45, 2260 (1973). 37. Gilbert B.L., Olson B.L., Reuter W., Anal. Chem., 46, 170 (1974). 38. Giraudi G., Grillo C., Anal. Chim. Acta, 128, 169 (1981). 39. Nagashima S., Anal. Chem., 56, 1944 (1984). 40. Sharma A., Thibert R.J., Mikrochim. Acta, 1985 I, 357. 41. Whiston T.G., Cherry G.W., Analyst, 87, 819 (1962). 42. Koh T., Iwasaki I., Bull. Chem. Soc. Jpn., 40, 569 (1967). 43. Guerrero A.H., Roig A.M.,Anal. Chem., 45, 1943 (1973). 44. Yamamoto Y., Tarumoto T., Hanamoto Y., Bull. Chem. Soc. Jpn., 42, 268 (1969). 45. Einaga H., Ishii H., Talanta, 20, 1017 (1973). 46. Roberts R.F., Wilson R.H., Analyst, 93, 237 (1968). 47. Galik A., Vopravilova J., Talanta, 21,307 (1974). 48. Mushtakova S.P. et al., Zavod. Lab., 51, No 6, 6 (1985). 49. Senise P., Oliveira R.L.,Anal. Chim. Acta, 81,419 (1976). 50. Ciuhandu G., Chieu A., Z. Anal. Chem., 255, 35 (1971). 51. Bock R., Bockholt B., Z. Anal. Chem., 260, 274 (1972). 52. Bell D.R., Reiszner K.D., West P.W., Anal. Chim. Acta, 77, 245 (1975). 53. Gorska R.W., Jarym-Agaeva N.T., Zh. Anal. Khim., 43, 651 (1988). 54. Selvapathy P., Pitchai R., Ramakrishna T.V., Talanta, 37, 539 (1990). 55. Lambert J.L., Chiang Y.C.,Anal. Chem., 55, 1829 (1983). 56. Aminot A., Kerouel R., Analusis, 18, 289 (1990). 57. Edwards R.T. et al., Anal. Chim. Acta, 261, 287 (1992). 58. Nazarenko V.A., Biriuk E.A., Antonovich V.P., Zavod. Lab., 33, 22 (1967).
151
Chapter 16. Chlorine Chlorine (C1, at. mass 35.45) exists at room temperature as a gas (C12) which has oxidizing properties. Chlorine occurs in several oxidation states: chloride -I, hypochlorite I, chlorite III, chlorate V and perchlorate VII. Chloride exhibits reducing properties towards powerful oxidants, such as Mn(VH) and Ce(IV). In its other oxidation states, chlorine has oxidizing properties. Hypochlorite and chlorite are rather unstable, and are subject to gradual disproportionation into chloride and chlorate. Of the chloro-anions, only chloride reveals strong complex-forming capacity.
16.1. Separation of chloride and chlorine Small amounts of chloride can be separated from many other elements by precipitation, as silver chloride, from dilute HNO3 [1 ]. Bromide, iodide, and thiocyanate are also precipitated. Chloride has been separated as PbCI2 with lead phosphate as a collector [2]. Chloride is often oxidized to chlorine and separated by distillation [3] (see the Methyl Red method). The chloride is oxidized with periodate, permanganate, or cerium(W), in a sulphuric acid medium, after separation of Br- and I- by oxidation to Br2 and I2 with potassium periodate in dilute HNO3. Chloride may also be separated by distilling the volatile hydrogen chloride, which is collected in a solution containing excess of silver ions [4]. Chromatographic separations of mixtures of halide ions by using strongly basic anion exchange resins have been proposed [5].
16.2. Determination of chloride and chlorine Chloride is often determined as AgC1 by the simple turbidimetric method, but spectrophotometric methods are more accurate, and more sensitive. Many such methods are based on the oxidation of chloride to chlorine, which undergoes subsequent redox reaction resulting in either the appearance or disappearance of colour (e.g., the Methyl Red method described below). In direct methods involving chloride ions, advantage is taken of the higher stability of the colourless Hg(II) chloride complex in comparison with that of other coloured Hg(II) complexes.
16.2.1. Methyl Red method The sample solution is placed in a still with an oxidizer which oxidizes chloride to C12. The chlorine is steam-distilled and trapped in a receiver containing an acidified solution of Methyl Red (formula 16.1). The oxidation of Methyl Red by chlorine results in a partial bleaching of the solution, thus orovidin~ a basis for an indirect method of determining chloride [6]. cooH
(CH,)zN~N~---'~Q=~ N
(16.1)
One molecule of the dye reacts with two molecules of chlorine (C12). The difference in
16.2. Determination of chloride and chlorine
153
absorbance of the Methyl Red solution before and after the reaction with chlorine enables one to calculate the value of e which expresses indirectly the sensitivity of the method. The molar absorptivity ~ = 1.17.104 (a = 0.33) at ~max : 515 nm. Chloride is oxidized with potassium periodate in a dilute sulphuric acid solution. The solution of KIO4 in H2804 is first heated to distil off any chlorine formed from chloride impurities in the reagents. The optimum acid concentration for the Methyl Red colour reaction with chlorine is 1 M H2804. Bromide and iodide interfere in this method. The presence of 5 ~tg of Br- increases the results by 60-70% in the determination of 5 ~tg of C1-. Positive errors owing to iodide are smaller and less reproducible, than those owing to bromide.
Reagents Methyl Red, 0.0005% solution in 1M H2804. Dissolve 50.0 mg of the dye in 1 M H2804 and dilute the solution with the acid in a volumetric flask to 1 litre. Dilute 25 ml of this solution with 1 M H2804 in a volumetric flask to 250 ml. Standard chloride solution: 1 mg/ml. Dissolve in water 1.6486 g of sodium chloride, previously ignited at 400-500~ and dilute the solution with water to volume in a 1-1itre standard flask. Periodate reagent. Add 200 ml of conc. H2804 to 300 ml of water, and mix. Place the cooled solution in a 750-ml distillation flask, and add 12 g of KIO4. When the salt has dissolved, add a few fragments of porous porcelain, connect the flask to the condenser, and distil off and discard the first 200 ml of water. To the cooled solution in the distillation flask add 200 ml of water, with stirring. Add a fragment of porcelain, and again distil off 200 ml of water. Transfer the cooled chlorine-free reagent solution to a glass-stoppered bottle.
Procedure
Preliminary preparation. Place 25 ml of the periodate reagent in the distillation flask, add 10 ml of water, and stir well. Add a few fragments of porous porcelain and distil 10 ml of water into a receiver containing 5 ml of the Methyl Red solution. Transfer the solution from the receiver to a 25-ml standard flask, make up to the mark with water, and measure the absorbance of the solution against water. The absorbance measured should not be lower than the absorbance of the solution obtained by diluting 5 ml of the Methyl Red solution with water in a 25-ml standard flask. If the absorbance is lower, add 10 ml of water to the distillation flask, and repeat the procedure described above.
Separation and determination of C1. Introduce 10 ml of the sample solution containing not more than 50 ~tg of C1 (chloride) into the distillation flask containing the periodate reagent prepared as described above. Mix the solution thoroughly, add a fragment of porcelain, and distil 10 ml of water together with the separated chlorine into the receiver containing exactly 5 ml of the Methyl Red solution. Transfer the solution from the receiver to a 25-ml standard flask, and dilute to the mark with water. Measure the absorbance of the partly decolorized red solution at 515 nm against water. Notes. 1. A weighed portion of the sample can be added to the distillation flask containing the periodate reagent, and 10 ml of water are then added. 2. Complete discoloration of the Methyl Red solution implies that too large a sample was taken. 3. The weight of a sample is limited by the solubility of the sample in the periodate. During distillation, the solution in the flask should remain clear.
154
16. Chlorine
4. The same aliquot of periodate reagent in the distillation flask can be used for several successive determinations of chloride (e.g., when preparing a calibration curve).
16.2.2. Turbidimetric method The method involves comparing the turbidity formed when silver nitrate is added to an acidified (HNO3) sample solution containing chloride, with the turbidity formed in standard solutions. The method is simple but has rather low precision. Instead of visual comparison of the turbidities in colorimetric cylinders, the absorbance can be measured with a photometer. The development of turbidity of AgC1 is a rather slow process. A time lapse of 15-20 rain after the addition of silver nitrate is necessary to allow the AgC1 precipitate to become stabilized. Variations of temperature within the range 20-30~ and of acidity between 0.01 and 0.1M HNO3 have no effect on the determination. An aqueous acetone medium stabilizes the suspension [7], but commercial acetone may contain chloride, and should, therefore, be purified by distillation in the presence of sodium hydroxide. Higher concentrations of electrolytes and organic compounds have adverse effects on the formation of the AgC1 sol. Ions which form precipitates with silver nitrate in acid medium, i.e., bromide and iodide, interfere in turbidimetric determinations. It has been proposed that one might precipitate AgC1 in the presence of gelatine under exposure to short-wave ultraviolet radiation. The absorbance of the resulting violet-brown colour is measured at 435 nm [ 8].
Reagents Silver nitrate, 0.1 M solution (--2%). Standard chloride solution: 1 mg/ml (preparation as in Section 16.2.1.). Potassium sulphate, 2% solution (chloride-free). Barium nitrate, 2% solution (chloride-free).
Procedure Co-precipitation of C l with a collector. Acidify the sample solution (100-200 ml) with HNO3, add 5 ml of the K2SO4 solution, and heat to -~80~ Add dropwise a mixture of 6 ml of the Ba(NO3)2 solution, and 2 ml of the AgNO3 solution with stirring. Keep the solution at -~ 60~ for 1 h, then cool and filter, using paper washed free from chloride, and wash the precipitate three times with --0.01 M HNO3 by decantation. Discard the filtrate, and add 10 ml of 2 M NH3 to a beaker containing the precipitate of BaSO4 and AgC1. Thoroughly mix the liquid and the precipitate, refilter (using the same filter paper), and wash the filter paper and the precipitate with dilute ammonia solution. The filtrate contains the separated chloride. Determination of chloride. Place the sample solution (or the ammoniacal filtrate obtained as described above), containing not more than 40 gg of chloride, in a Nessler cylinder, acidify with dilute HNO3 (to make the final solution 0.05 M HNO3), dilute with water to 40 ml, add 2 ml of AgNO3 solution, and stir well. Prepare at the same time a series of standards covering the range 0-40 lag of C1- in exactly equivalent Nessler cylinders. Let the cylinders stand for 15 min in the dark, and then compare the turbidity obtained in the sample solution with that of the standards. The cylinders should be observed from above, against a black background, in a brightly and uniformly lit location.
16.2. Determination of chloride and chlorine
155
16.2.3 Other methods for determining chloride and chlorine Several methods for determining small amounts of chlorine are based on the oxidation of certain organic reagents in a colour reaction, which serves as a basis for spectrophotometric determination. The same principle is used in determining chlorides after they are oxidized to chlorine. Among the organic reagents used in this procedures are: Methyl Red (discussed above), o-tolidine (formula 16.2) (e = 3.4.10 4) [1,9,10], Methyl Orange (e = 4.0.10 4) [1012], and dicarboxidine [13]. The method has been applied also in the FIA technique [10].
HzN~ ' ~ . _ ~ ~ ~ ~ ~
NHz
(16.2)
In the benzidine-pyridine method [14,15], chlorine reacts with cyanide ions to form cyanogen chloride (CNC1). The product of the reaction of CNC1 with pyridine (glutaconaldehyde) is condensed with primary amines to form polymethine dyes. Chlorine in air can be determined by passing air through an alkaline solution of 4nitroaniline and measuring the absorbance of the compound formed (e= 1.9.10 4 at 485 nm) [ ! 6]. Chlorine in tap-water has been determined by adding phenolphthalein (in the reduced form) and ferrocyanide. The ferricyanide ions formed produce an equivalent amount of red phenolphthalein (in alkaline medium) [17]. When a solution containing chloride is passed through a column of granular silver iodate, the chloride displaces an equivalent amount of IO3-, which reacts with I- added to give iodine (3 molecules of I2 per mole of C1- ion), which can be determined by the starchiodine method (see Section. 25.2.1) [18,19]. In the indirect thioeyanate method (not very sensitive, e~5.103) the determination of chloride [20-28] has been based on the displacement of SCN- ion from the mercury(H) thiocyanate complex by chloride ions, to give a stable mercury chloride complex. After addition of Fe(III) in excess, the red Fe(SCN) 2+ complex is formed, and the absorbance is measured at 480 nm. In the FIA method the UV detection has been applied in the absence of Fe(III) ions [29]. In another indirect method for determining chloride use is made of the fact that HgC12 is more stable than the violet Hg(II) diphenylearbazone complex [30,31 ]. The violet colour of the solution is a function of the chloride concentration. In other indirect methods chloride displaces Methylthymol Blue [32] or Xylenol Orange [33] from their complexes with mercury(H).
16.3. Determination of other chlorine compounds Perchlorate ions form extractable ion-associates with basic dyes such as Brilliant Green (e= 9.4.104) [34,35], Malachite Green [36,37], Crystal Violet [38], Methylene Blue [39], and the oxidized form of Variamine Blue [40]. Chloroform, dichloroethane, benzene, nitrobenzene and toluene have been used as extractants. Perchlorate impurities in potassium chlorate have been determined by these sensitive methods [34]. The FIA technique has been applied in the determinations [35]. Methods based on extractable ion-pairs of C104- with bathoferroin [41], and neocuproin [42] are less sensitive. In an indirect method, perchlorate has been determined by extraction
156
16. Chlorine
with the tetrabutylphosphonium ion into o-dichlorobenzene, followed by displacement of the C104- by the Fe(III)-thiocyanate complex anion to form a coloured complex. The method was used for determining 0.003% C104- in potassium chlorate [43]. The oxidizing properties of chlorate are utilized in its spectrophotometric determination. Chlorate admixtures in perchlorates have been determined by its colour reaction with benzidine [44] and bis-thiosemicarbazone dimedone (e= 1.9.104 at 417 nm) [45]. Chlorate in water has been determined with o-tolidine [46]. At a suitably high chloride concentration in 3-7 M H2804, chlorate reacts quantitatively with C1- to form C12, which decreases the absorbance of Methyl Orange [47]. Chlorine dioxide is determined from its absorbance as the coloured product ()Lmax = 490 nm) of its reaction with tyrosine [48]. Chlorine dioxide has been found to reduce the absorbance of Acid Chrome Violet K [49]. Spectrophotometric methods of determining C102 with the use of Chlorophenol Red have been proposed [50,51]. A scheme for analysing mixtures of CI-, C10-, C102-, C103-, C104-, and C102 using spectrophotometric and other methods has been devised [52].
16.4. Analytical applications The Methyl Red methods have been used for determining trace amounts of chloride in chemical reagents (sulphates, phosphates, oxides, hydroxides) [6]. The method cannot be used for determining traces of chloride in nitrates, as some nitric acid can be, formed which oxidizes and bleaches Methyl Red. When free chlorine is determined in tap water, a sample of water is placed in a still (with no oxidizer) and chlorine is distilled, along with some water, into a receiver containing Methyl Red. The sample water may also be added directly to a Methyl Red solution. The turbidimetric method has been used in automated determinations of chloride in natural and potable waters [53]. Chlorine has been determined in water [14,15] and in selenium [54] by the benzidinepyridine method. The indirect thiocyanate method has been applied for determining chloride in blood serum [27], water [2,55,56], plants [57,58], industrial waste waters [24], geological materials [59], organic substances [60,61], barium sulphate [28], silicate minerals [62], and catalysts [63]. The FIA technique was used in determination of chlorine in ethanol [64]. A sensitive method for determining chlorine in tap water has been based on the reaction of chlorine with thio-Michler's ketone (formula 46.2) (~ = 7.7.104 at 640 nm). The method has been applied in the FIA technique [65]. The reaction of chlorine with 4-nitroaniline has been applied in the continuous method of determining chlorine in air [66]. Another method of determining chlorine in air ias been based on the liberation of an equivalent amount of iodine, which as 13- forms an extractable ion associate with Crystal Violet [67].
References 1. Scheubeck E., Ernst O., Z. Anal. Chem., 254, 185 (1971). 2. Rodabaugh R.D., Upperman G.T., Anal. Chim. Acta, 60, 434 (1972). 3. Elsheimer H.N., Johnston A.L., Kochen R.L., Anal. Chem., 38, 1684 (1966). 4. Reichel W., Acs L., Anal. Chem., 41, 1886 (1969). 5. Zalevskaya T.L., Starobinets G.L., Zh. Anal. Khim., 24, 721 (1969).
References 6. Marczenko Z., Lenarczyk L., Chem. Anal. (Warsaw), 11, 1221 (1966). 7. Palei P.N., Udal'tsova N.I., Zavod. Lab., 30, 151 (1964). 8. Hoffmann H.E., Z. Chem., 17, 147 (1977). 9. Johnson J.D., Overby R.,Anal. Chem., 41, 1744 (1969). 10. Leggett D.J., Chen N.H., Mahadevappa D.S., Analyst, 107, 433 (1982). 11. Laitinen H.A., Boyer K.W., Anal. Chem., 44, 920 (1972). 12. D'Amboise M., Meyer-Grail F., Anal. Chim. Acta, 104, 355 (1979). 13. Gr6ningsson K., Analyst, 104, 367 (1979). 14. Nicolson N.J., Analyst, 90, 187 (1965). 15. Webber H.M., Wheeler E.A., Analyst, 90, 372 (1965). 16. Gabbay J., Davidson M., Donagi A.E., Analyst, 101, 128 (1976). 17. Shahine S.A., Mahmoud R.M., Microchem. J., 21, 286 (1976). 18. Mor E.D., Beccaria A.M., Poggi G., Anal. Chim. Acta, 99, 361 (1978). 19. Utsumi S., Yokota J., Isozaki A., Bunseki Kagaku, 29, 703 (1980). 20. Elsheimer H.N., Kochen R.L., Anal. Chem., 38, 145 (1966). 21. Florence T.M., Farrar Y.J., Anal. Chim. Acta, 54, 373 (1971). 22. Kirsten W.J., Lindholm-Franzen I., Microchem. J., 25, 240 (1980). 23. Vekid B., Ra~em D.,Anal. Chim. Acta, 193, 331 (1987). 24. Van Staden J.F.,Anal. Chim. Acta, 261,453 (1992). 25. Yoshinaga T., Ohta K.,Anal. Sci., 6, 57 (1990). 26. Tanase I., Ioneci I., Dumitrescu V., Rev. Chim. (Bucarest), 40, 1004 (1989). 27. Van Staden J.F., Talanta, 38, 1033 (1991). 28. Torrades F., Castellvi M., Fresenius'J. Anal. Chem., 349, 734 (1994). 29. Cirello Egamino J., Brindle I.D., Analyst, 120, 183 (1995). 30. Kemula W., Hulanicki A., Janowski A., Talanta, 7, 65 (1960). 31. Novak J., Hauptman Z., Z. Anal. Chem., 217, 340 (1966). 32. Nomura T., Komatsu S., J. Chem. Soc. Jpn. Pure Chem. Sect., 90, 168 (1969). 33. Humphrey R.E., Hinze W.L., Anal. Chem., 45, 1747 (1973). 34. Burns D.T., Tungkananuruk N., Anal. Chim. Acta, 199, 237 (1987). 35. Burns D.T., Chimpalee N., Harriott M.,Anal. Chim. Acta, 217, 177 (1989). 36. Akiyama S. et al., Bull. Chem. Soc. Jpn., 56, 947 (1983). 37. Galban J., Urarte M.L., Aznarez J., Microchem. J., 41, 84 (1990). 38. Uchikawa S., Bull. Chem. Soc. Jpn., 40, 798 (1967). 39. Iwasaki I., Utsumi S., Kang C., Bull. Chem. Soc. Jpn., 36, 325 (1963). 40. Tusakova N.N., Mushtakova S.L., Frumina N.S., Zavod. Lab., 46, 22 (1980). 41. B~kowski W., Ba:kowski A., Microchem. J., 29, 137 (1984). 42. Weiss J.A., Stanbury J.B., Anal. Chem., 44, 619 (1972). 43. Fogg A.G., Burns D.T., Yeowart E.H., Mikrochim. Acta, 1970, 974. 44. Burns E.A., Anal. Chem., 32, 1800 (1960). 45. Leyva J.A., Mochon M., Diaz N., Misiego M., Mikrochim. Acta, 1984 III, 295. 46. Urone P., Bonde E., Anal. Chem., 32, 1666 (1960). 47. Yamasaki S. et al., Bunseki Kagaku, 28, 566 (1979). 48. Tumanova T.A., Pakhomova L.N., Maiorova L.P., Zavod. Lab., 36, 1036 (1970). 49. Knechtel J.R., Janzen E.G., Davis E.R., Anal. Chem., g0, 202 (1978). 50. Fletcher I.J., Hemmings P.,Analyst, 110, 695 (1985). 51. Sweetin D.L., Sullivan E., Gordon G., Talanta, 43, 103 (1996). 52. Prince L.A., Anal. Chem., 36, 613 (1964). 53. Ramirez-Munoz J.,Anal. Chim. Acta, 74, 309 (1975). 54. Barasel D., Jaetsch K., Z. Anal. Chem., 249, 234 (1970).
157
158
16. Chlorine
55. Rodabaugh R.D., Upperman G.T., Anal. Chim. Acta, 60, 434 (1972). 56. Ru~i6ka J., Stewart J.W., Zagatto E.A.,Anal. Chim. Acta, 81, 387 (1976). 57. Fessel Graner C.A., Paulucci J.B.,Anal. Chim. Acta, 123, 347 (1981). 58. Allen C.R., Allen S., Anal. Biochem., 173, 54 (1988). 59. Chan C.C., Lab. Rob. Autom., 2, 83 (1990). 60. Rowe R.D., Anal. Chem., 37, 368 (1965). 61. Marquardt R.P., Anal. Chem., 43, 277 (1971). 62. Huang W.H., Johns W.D., Anal. Chim. Acta, 37, 508 (1967). 63. Koshy V.J., Garg V.N., Talanta, 34, 905 (1987). 64. Krug F.J. et al., Anal. Chim. Acta, 130, 409 (1981). 65. Zenki M., Komatsubara H., T6ei K.,Anal. Chim. Acta, 208, 317 (1988). 66. Shina A., Gabbay J.,Analyst, 111, 183 (1986). 67. Lomonosov S.A., Shukolukova N.I., Chernoukhova V.I., Zh. Anal. Khim., 28, 2389 (1973).
Chapter 17. Chromium Chromium (Cr, at. mass 52.00) occurs in a series of coloured species corresponding to the II-, III-, and VI- oxidation states. In spectrophotometric analysis, Cr 3+, CrO42-, and Cr207 zions are determined. Chromium(III) hydroxide, which precipitates at pH-5, is amphoteric, dissolving in strongly alkaline media. Chromium(III) forms inert complexes, e.g., with oxalate, tartrate and EDTA. Chromium(II) is a strong reducing agent, and chromium(VI) has oxidizing properties.
17.1. Methods of separation and preconcentration 17.1.1. Extraction Comprehensive studies of the behaviour of traces of chromium, and of methods of separation, have been presented [ 1]. A selective, and fairly simple method for separating chromium is the extraction of chromium(VI) with MIBK from 1-3 M hydrochloric acid [1,2]. The method enables chromium to be separated from most elements (e.g., V, Fe, Mn, and Ni). Only In, T1, Sb, Hg, W, and Re are co-extracted if present in significant quantities (>1%). The recommended procedure involves extracting Cr(VI) with 2 portions of MIBK from 2 M HC1, washing the extract with 2 M HC1, and stripping the chromium with water. Chromium(VI) has been extracted with mesityl oxide from 1 M HC1 and 2.5 M KC1 medium, and stripped with dilute ammonia [4]. Inert solvents (e.g., CHC13, C6H6, 1,2-dichloroethane) extract ion-associates of chromate with high molecular-weight amines, e.g., TOA [4], tribenzylamine [5], and 4-(5nonyl)pyridine [6], from acid media (HC1, H2SO4, HC104, HNO3). TOPO in benzene and a tetraphenylarsonium salt in CHC13 have also been used [ 1]. In an acidic medium (pH---1.7) and at a temperature not higher than 10~ chromium(VI) reacts with H202 (-0.02 M) to form blue perchromic acid which can be extracted into ethyl acetate, isoamyl alcohol, or similar oxygen-containing solvents. These methods permit the separation of Cr from V, Fe, and most other metals [7]. Perchromic acid can also be extracted with solutions of tertiary amines or quaternary ammonium salts [8,9]. The anionic thiocyanate complex of chromium(III) has been extracted with MIBK or cyclohexanone [10] , and with 5% TOA in CC14 [11] . The complexes of Cr(III) with NTA [12] or DCTA [13,14] have been extracted with solutions of Aliquat 336 in CHC13 or 1,2-dichloroethane. Methods of solvent extraction of chromium have been reviewed [ 15].
17.1.2. Precipitation and other methods Traces of chromium(III) are precipitated as the hydroxide with NaOH (in moderate excess), or with ammonia. Fe(III), A1, Zn, or La (2-4 mg) are used as collectors [1,16,17]. When a sample is fused with Na202 or NazCO3 (with or without KNO3), Cr(III) is oxidized to Cr(VI), which is leached from the melt with water, whereas Fe, Mn (reduced with ethanol from MnO42- to MnO2 aq), Cu, Ni, Co, Ti, and most other metals remain in the solid phase. Losses of chromium owing to retention in the precipitate are insignificant. Such
160
17. Chromium
elements as V, Mo, As, and A1 pass into the alkaline solution together with Cr(VI), when the melt is leached with water. Chromium(III) can be oxidized in a hot alkaline solution (NaOH) to soluble CrO42- with H202 or bromine. Traces of chromium(VI) can be separated by coprecipitation with barium or lead sulphate [18]. Since chromium(m) is not retained on anion exchangers when 0.02-12 M HC1 is used as eluent, it can be separated from a number of metals [1]. Strongly basic anion-exchangers retain V(V), Cr(VI), and Mo(VI) from acetate solution at pH 2.5-3. These metals are washed out with 0.6 M NaOH, 8 M HC1, and 1 M HC1, respectively. Many metals can be separated from chromium by retaining Cr(VI) ions on strongly basic anion exchangers [19,20]. Water samples containing chromate are adjusted to pH --5 and passed through an anion-exchange resin bed (C1-). The chromate is eluted with a solution of an acidic reductant [21 ]. The distillation of chromium as CRO2C12, normally applied for separation of macroamounts of Cr, has also been applied with success in the separation of traces. The distillation is carried out at 200-210~ from a perchloric acid medium, through which CO2 and HC1 are bubbled [ 1].
17.2. Methods of determination Chromium is usually determined by the diphenylcarbazide method. This method is particularly useful for determining traces of chromium. Larger amounts of chromium can be determined either by the chromate method, or by the method based on the Cr(III)-EDTA complex.
17.2.1. Diphenylcarbazide method 1,5-Diphenylcarbazide reacts in acid medium with chromium(VI) ions to give a violet solution which is the basis of this sensitive method. It has been shown that the cationic Cr(III)-diphenylcarbazone complex is formed by oxidation of diphenylcarbazide with chromium(VI). It has been assumed that the reaction proceeds with nascent, not yet hydrated Cr(III) ions, obtained in the reduction of Cr(VI) with diphenylcarbazide which is oxidized to diphenylcarbazone:
0
0
(17.1)
The molar absorptivity, ~, of the coloured product of the chromium(VI) reaction with 1,5diphenylcarbazide is 4.3.104 (a = 0.83) at )Lmax = 545 nm. The colour intensity obtained in the reaction depends on the quality of the 1,5-diphenylcarbazide used [22,23]. The oxidation of Cr 3+ to Cr2072- is critical for the determination of Cr by the diphenylcarbazone method. The oxidation is normally done in acid medium with KMnO4 or with (NH4)28208 in the presence of silver ions. The excess of MnO4- is either decomposed by azide or precipitated as MnO2 aq in the presence of Mn 2+ ions. The excess of persulphate is either decomposed by boiling the solution or reduced by azide. Fusing solid samples with sodium carbonate or sodium peroxide converts Cr(III) into Cr(VI). Since the absorbance of the solution varies with acidity, the pH should be kept constant at the optimum value of pH --1
17.2. Methods of determination
161
(--0.05 M H2SO4). The presence of HC1 should be avoided. The diphenylcarbazide method is almost specific for chromium(VI). Interferences result only from Fe, V, Mo, Cu, and Hg(II) present at much higher concentrations than the chromium. Iron(III) can be masked by phosphoric acid or EDTA. Iron(III) can also be separated as Fe(OH)3, after chromium has been oxidized to Cr(VI), or by extraction. Vanadium can be separated from Cr(VI) by extraction as its oxinate at pH --4. Molybdenum is masked with oxalic acid, and Hg(II) is converted into the chloride complex. When small amounts of Cr(III) are to be determined in the presence of Cr(VI), the Cr(III) is first separated by precipitation of the hydroxide, with A1 or Fe(III) as the collector and ammonia as the precipitant. The precipitate is then dissolved, and the Cr(III) is oxidized to Cr(VI) and determined with diphenylcarbazide. Traces of Cr(VI) were determined in Cr(III) after Cr(VI) had been leached with 0.1 M NaOH [24]. The preliminary extraction of Cr(VI) before its determination with 1,5-diphenylcarbazide has been discussed elsewhere [3,25].
Reagents 1,5-Diphenylcarbazide, 0.2% solution in acetone. Dissolve 0.2 g of the reagent in 100 ml of acetone containing 1 ml of H2SO4 (1 +9). Keep the solution in an amber-glass bottle. Standard Cr(VI) solution: 1 mg/ml. Dissolve in water 2.8300 g of KzCr207 previously dried at 140~ and dilute the solution with water to volume in a 1 litre standard flask. Potassium permanganate, -.0.02 M solution. Sodium azide, NAN3, 2.5% solution.
Procedure Place in a beaker a solution containing not more than 20 ~tg of Cr. If the solution contains chloride add a little sulphuric acid, and evaporate to fumes. Cool the residue, add --15 ml of water and 3 or 4 drops of KMnO4 solution, cover the beaker with a watch glass, and heat without boiling for 15 min. The acidity of the solution should at this point be 0.05- 0.1 M H2SO4. If the pink colour disappears in the course of heating, add more KNInO4 solution dropwise. Reduce (decolorize the pink solution) the excess of oxidant (MnO4- or MnO2 aq.) by adding sodium azide solution dropwise, waiting a few sec after the addition of each drop. Transfer the cooled solution to a 25-ml standard flask, add 1 ml of the diphenylcarbazide solution, dilute the solution with water to the mark, and mix thoroughly. Measure the absorbance at 545 nm, using water as the reference.
17.2.2. Chromate method The method for the determination of chromium, based on the colour of Cr2072- or CrO42- ions, is an example of a precise but rather insensitive method. It may be based either on the greenish-yellow colour of CrO42- ions present in alkaline solution, or on the orange-yellow colour of dichromate Cr2072- ions, formed from CrO42- ions by acidification of the solution. Figure 17.1 shows the absorption spectra of dichromate (1) and chromate (2). The absorP3tion peaks lie in the near-ultraviolet at 350 nm (~ = 7.5.102) and at 373 nm (~ = 1.4.10 ), respectively. The molar absorptivity of dichromate at 400 nm is only 1.6.10 2 (a 0.003). The concentration of the acid in dichromate solutions affects the colour. An approximately 1 M H2SO4 medium is most suitable. If chromium is present as Cr(III), it must first be oxidized to Cr(VI). In acid media (H2SO4, HC104), chromium can be oxidized with permanganate, persulphate in the presence 9
9
9
9
162
17. Chromium
of Ag + ions as catalyst, bismuthate, or periodate. Perchloric acid oxidizes chromium(HI) when heated to boiling (-~200~
t,..) Ol
! 350 373
t,00
,
.,
500
wavelengm, nm
Fig. 17.1. Absorption spectra of dichromate (in 1 M H2S04) (1) and chromate (in ammoniacal medium) (2) In alkaline media, Cr(III) can be oxidized with bromine, H202, or Na202. Fusion with an alkaline flux (NazCO3, Na202) also converts chromium into Cr(VI). The alkaline medium enables chromium(VI) to be separated easily from the majority of metals which form coloured solutions and give sparingly soluble hydroxides [Fe(III), U(VI), Ce(IV), Cu, Co, Ni]. Any coloured MnO4- ions formed during the oxidation are reduced with sodium azide or oxalic acid. In the presence of phosphoric acid which may be added to mask Fe(III), the colour of the solution is slightly changed owing to the formation of the mixed chromate-phosphate ions HCrPO72- and HzCrPO7-. In the extraction-spectrophotometric methods, the ion-association complexes of dichromate ions (in dilute H2SO4 medium) with tribenzylamine, TOA or Aliquat 336 [4], tetraphenylarsonium ion [26], or 1-naphthylmethyltriphenylphosphonium ion [27] are extracted into CHC13 or 1,2-dichloroethane.
Reagents Potassium permanganate,--0.02 M solution. Sodium azide, NAN3, 2.5% solution. Standard chromium(VI) solution: 1 mg/ml. Preparation as in Section 17.2.1.
Procedure Oxidize the chromium to Cr(VI) in a solution containing not more than 3 mg of Cr, as described in the diphenylcarbazide method. [More KMnO4 will be needed, in this case, if the Cr(III) content is greater]. Neutralize the chromium(VI) solution, and then add 5 ml of H2SO4 (1+3) . Make the solution up to the mark with water in a 25-ml standard flask, and measure the absorbance at 400 nm against water. Notes. 1. Chromium(VI) standard solution is used to construct the calibration curve. The procedure is thereby simplified, the oxidation of chromium being unnecessary. 2. For absorbance measurement of chromate an alkaline medium is required; 0.1 M sodium or potassium carbonate solution is suitable.
17.2. Methods of determination
163
17.2.3. E D T A method Ethylenediaminetetraacetic acid (EDTA, formula 17.2) forms coloured complexes with cations which have chromophoric properties (e.g., Fe, Cr, Cu, Co, Ni). These complexes, which are not very intensely coloured, form the basis of several less sensitive spectrophotometric methods, such as that for chromium(HI)
o>.,0,,
HO "N"--CH2"--CHz~N-- 0 H~~CH2C/ "CH2C(oH
(17.2)
With chromium(III), EDTA forms a violet complex in slightly acidic medium. The complex is formed slowly in the cold, but more rapidly if the solution is heated [28,29]. The sensitivity of the method is not high. The molar absorptivity is 1.4.102 at 540 nm (a = 0.003). The colour intensity diminishes as the pH is reduced. In a hot solution EDTA reduces Cr(VI) to Cr(III). This reaction is catalyzed by traces of Mn(II). Coloured ions, and those giving coloured complexes with EDTA, interfere in the determination of chromium as its EDTA complex. Oxalic and citric acids interfere in the colour reaction. The chromium(III-EDTA complex has been extracted by a solution of Aliquat-336 in non-polar solvents before the spectrophotometric determination [30]. As with EDTA (Complexone III) , DCTA ( Complexone IV) has also been used as a spectrophotometric reagent for chromium [13,14,17,31,32]. The Cr(III)-DCTA complexes have been extracted with chloroform solutions of Aliquat 336 [13,14].
Reagents EDTA, 2.5 % solution of the disodium salt. Standard chromium(HI) solution: 1 mg/ml. Dissolve 9.1970 g of chrome alum CrNH4(SO4)2.12H20 in water containing 2 ml of conc. H2SO4, and accurately dilute the solution with water to 1 litre. Working solutions are obtained by suitable dilution of the standard solution with 0.01 M H2804.
Procedure To the sample solution (10-15 ml) containing not more than 3 mg of Cr, add a little NHzOH.HCI and 3 ml of the EDTA solution. Adjust the solution with ammonia to pH 4-5, and heat to boiling. Continue gentle boiling for 2 min, then cool and dilute the solution to volume with water in a 25-ml standard flask. Measure the absorbance at 540 nm, using water as the reference.
17.2.4. Other methods The azo reagents are often used for determination of chromium as Cr(III). Cr was also determined with PAR [33]. The methods based on the ion-association compound of Cr 3+ with PAR and Zephiramine (CHC13, ~;= 4.7.104 at 540 nm) [34] or xylometazolinium cation (e = 4.8.104 at 530 nm) [35] are much more sensitive. A lesser sensitivity is attained in the method based on the ternary complex with PAR and H202. Sensitive methods are based on 5-Br-
164
17. Chromium
PADAP (formula 4.3, e = 7.9.104 at 600 nm) [37-39]. Cr(III) has also been determined with TAR (e = 5.0.104) [40], TAN [41] and Arsenazo III (~ = 2.6.104) [42]. Because of the considerable inertia of the Cr(III) complexes all the reactions involving azo reagents should be carried out after a short heating to 90-100 ~ Methods for chromium with use of triphenylmethane reagents are less sensitive; examples are: Chrome Azurol S (~ = 5.9.104) [43,44], Xylenol Orange (~ = 1.0.104) [45], and Malachite Green [46]. A much higher sensitivity is obtained when Cr(III) is determined with the use of Eriochrome Cyanine R in the presence of surfactant CTA (~ = 6.8.104) [47]. Cr(III) was determined with Eriochrome Cyanine by means of the derivative spectrophotometry [48]. Other organic reagents recommended for determining chromium include phenylfluorone [49] and o-nitrophenylfluorone (in the presence of CTA) (e = 1.1.105 at 582 nm) [50], Methylene Blue (~ = 8.3.104) [51], Pyrogallol Red [52], morin [53], and 2,2'-diquinoxalyl [54]. Chromium was also determined by a sensitive method based on the ion-associate of Cr(VI) with Rhodamine 6G in aqueous solution containing poly(vinyl alcohol) [55], and after extraction into toluene [56]. In an indirect method, the chromium(VI) is used to oxidize Fe(II) to Fe(III), which then forms a coloured complex with Tiron [57]. In another method, a known amount of iron(II) is added in excess to the Cr(VI) solution and the surplus is determined with ferrozine [58].
17.3. Analytical applications The flow-injection technique (FIA) has been applied for determining chromium(VI) with 1,5diphenylcarbazide [59-64], Cr(VI) and Cr(III) in the same solution [65-67], and Cr in the presence of iron [68]. The product of the Cr reaction with diphenylcarbazide was floated with lauryl sulphate [69]. Ion exchange on a mixed ion-exchange bed has been also used for the pre-concentration of that product [70]. 1,5-Diphenylcarbazide has been used for determining chromium in biological samples [71,72], water [16,18,73-77], soil [78,79], industrial waste waters [80], wood [81], various minerals [24,82,83], ilmenite [84], sapphires and rubies [85], tin [86], palladium 87], rhenium and its compounds [88], cerium dioxide [89], and salts of alkali metals [6]. Diphenylcarbazide was also applied in the determination of chromium speciation in silicon [90], and after preliminary separation of Cr(III) and Cr(VI) by HPLC [91 ]. The chromate method has been applied for determining chromium in, for example, steels [26], catalysts [92], and natural waters [93,94]. The EDTA method was used for determining Cr in soils and refractory materials [95] and in ores [96,97]. Among the other methods mentioned above, Chrome Azurol S was used for determining Cr in steel [44], and Rhodamine 6G was used for determining Cr in steels, geological samples, and sewage [51].
References 1. Beyermann K., Z. Anal. Chem., 190, 4; 191, 346 (1962). 2. Katz S.A., McNabb W.M., Hazel J.F.,Anal. Chim. Acta, 25, 193 (1961); 27, 405 (1962). 3. Shinde V.M., Khopkar S.M., Z. Anal. Chem., 249, 239 (1970). 4. Adam J., Pfibil R., Talanta, 18, 91 (1971). 5. Donaldson E.M., Talanta, 27, 779 (1980). 6. Iqbal M., Ejaz M.,Anal. Chem., 47, 936 (1975). 7. Tuck D., Anal. Chim. Acta, 27, 296 (1962). 8. Sastri M.N., Sundar D.S., Anal. Chim. Acta, 33, 340 (1965).
References
165
9. Barakat S.A., Burns D.T., Harriott M.,Anal. Chim. Acta, 272, 135 (1993). 10. Sukhanovskaya A.I. et al., Zh. Anal. Khim., 25, 1563 (1970). 11. McClellan B.E. et al., Anal. Chem., 46, 306 (1974). 12. Irving H.M., A1-Jarrah R.H., Anal. Chim. Acta, 60, 345 (1972). 13. Adam J., Pfibil R., Talanta, 21, 1205 (1974). 14. Kinhikar G.M., Dara S.S., Talanta, 21, 1208 (1974). 15. Rao V.M., Sastri M.N., Talanta, 27, 771 (1980). 16. Chuecas L., Riley J.P., Anal. Chim. Acta, 35, 240 (1966). 17. Fuhrman D.L., Latimer G.W., Talanta, 14, 1199 (1967). 18. Yamazaki H.,Anal. Chim. Acta, 113, 131 (1980). 19. Fritz J.S., Sickafoose J.P., Talanta, 19, 1573 (1972). 20. Mulokozi A.M.,Analyst, 97, 820 (1972); Talanta, 20, 1341 (1973). 21. Pankow J.F., Janauer G.E., Anal. Chim. Acta, 69, 97 (1974). 22. Willems G.J., Lontie R.A., Anal. Chim. Acta, 51, 544 (1970). 23. Friese B., Umland F., Z. Anal. Chem., 286, 107 (1977). 24. Mocak J., Vani6kova M., Labuda J., Mikrochim. Acta, 1985 II, 231. 25. Adam J., Pfibil R., Talanta, 21, 616 (1974). 26. Baishya N.K., Barnah G., J. Indian Chem. Soc., 59, 389 (1982). 27. Burns D.T., Kheawpintong S., Anal. Chim. Acta, 177, 253 (1985). 28. Den Boef G., Poeder B.C., Anal. Chim. Acta, 30, 261 (1964). 29. Fuji Y., Kyuno E., Tsuchiya R., Bull. Chem. Soc. Jpn., 42, 1569 (1969). 30. Irving H.M., A1-Jarrah R.H.,Anal. Chim. Acta, 63, 79 (1973). 31. Fuhrman D.L., Latimer G.W., Jr., Talanta, 14, 1199 (1967). 32. Panel J., Coll. Czech. Chem. Comm., 50, 2840 (1985). 33. Ivanov V.M., Golubitskii G.B., Gen'i L.I., Zh. Anal. Khim., 40, 36 (1985). 34. Yotsuyanagi T. et al.,Anal. Chim. Acta, 67, 297 (1973). 35. Anjaneyulu Y., Reddy M.R., Kavipurapu C.S.,Analyst, 111, 1167 (1986). 36. Ferng W.B., Parker G.A., Z. Anal. Chem., 304, 382 (1980). 37. Wei Fu-sheng et al., Mikrochim. Acta, 1982 II, 67. 38. Guo-zhen Fang, Cui-ying Miao, Analyst, 110, 65 (1985). 39. Rathaiah G.V., Eshwar M.C., Analyst, 111, 61 (1986). 40. Subrahmanyam B., Eshwar M.C., Mikrochim. Acta, 1976 II, 579. 41. Rathaiah G.V., Eshwar M.C., Bull. Chem. Soc. Jpn., 58, 2447 (1985). 42. Tataev O.A., Guseinov V.K., Zh. Anal. Khim., 30, 935 (1975). 43. Pantaler R.P., Pulyaeva I.V., Zh. Anal. Khim., 50, 1634 (1985). 44. Fang G.Z., Liu J.K., Talanta, 39, 1579 (1992). 45. Tataev O.A., Abdulaev P.P., Zh. Anal. Khim., 25, 930 (1970). 46. Parkash R., Bansal R., Kaur A., Rehani S.K., Talanta, 38, 1163 (1991). 47. Jarosz M., Biernat J., Chem. Anal. (Warsaw), 33, 685 (1988). 48. E1-Sayed A.Y., Abd-Elmottaleb M., Anal. Lett., 27, 1727 (1994). 49. Izquierdo-Hornillos et al., Anal. Chim. Acta, 142, 325 (1982). 50. Wen-bin Qi, Li-zhong Zhu, Talanta, 33, 694 (1986). 51. Kamburova M., Talanta, 40, 713 (1993). 52. Sicilia D., Rubio S., Perez Bendito D., Anal. Chim. Acta, 284, 149 (1993); 297, 453 (1994). 53. E1-Sayed A.Y., Khalil M.M., Talanta, 43, 583 (1996). 54. Baranowska I., Microchem. J., 26, 55 (1981). 55. Liu Shaopu, Wang Fuchang, Talanta, 38, 801 (1991). 56. Maheswari V., Balasubramanian N., Chem. Anal. (Warsaw), 41, 569 (1996). 57. Abdullah K.A., Hassan Y.I., Bashir W.A., Microchem. J., 27, 319 (1982).
166 58. 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. 69. 70. 71. 72. 73. 74. 75. 76. 77. 78. 79. 80. 81. 82. 83. 84. 85. 86. 87. 88. 89. 90. 91. 92. 93. 94. 95. 96. 97.
17. Chromium
Bet-Pera F., Jaselskis B., Analyst, 106, 1234 (1981). De Andrade J.C. et al.,Analyst, 108, 621 (1983). De Andrade J.C., Rocha J.C., Baccan N., Analyst, 109, 645 (1984). Whitaker M.J.,Anal. Chim. Acta, 174, 375 (1985). Alonso-Chamarro J., Bartroli J., Barber R., Anal. Chim. Acta, 261, 219 (1992). Peixoto C.R., Goshikem Y., Baccan N., Analyst, 117, 1029 (1992). Andrade F.J., Tudino M.B., Troccoli E., Analyst, 121, 613 (1996). De Andrade J.C., Rocha J.C., Baccan N., Analyst, 110, 197 (1985). Ruz J. et al.,Anal. Chim. Acta, 185, 139 (1986); Talanta, 33, 199 (1986). Matsouka S. et al., Analyst, 124, 787 (1999). Martelli P.B. et al., Anal. Chim. Acta, 308, 397 (1995). Aoyama M., Hobo T., Suzuki S., Anal. Chim. Acta, 129, 237 (1981). Shijo Y., Sakai K., Bull. Chem. Soc. Jpn., 59, 1455 (1986). Bryson W.G., Goodall C.M., Anal. Chim. Acta, 124, 391 (1981). Agterdenbos J. et al., Talanta, 19, 341 (1972). Yoshimura K., Ohashi S., Talanta, 25, 103 (1978). Manzoori J.L., Sorouraddin M.H., Shemiran F., Anal. Lett., 29, 2007 (1996). Ososkov V., Kebbekus B., Chesbro D., Anal. Lett., 29, 1829 (1996). Savvin S.B. et al., Zh. Anal. Khim., 51,308 (1996). Osaki S., Osaki T., Takashima Y., Talanta, 30, 683 (1983). Solano G. et al., J. Radioanal. Nucl. Chem., 179, 173 (1994). Milacic R. et al.,Analyst, 117, 125 (1992). Barrais P.,Analusis, 17, 87 (1989). Williams A.J., Analyst, 93, 611 (1968). Nechitailov A.A., Prokof'ev V.V., Krasin'kova M.V., Zh. Anal. Khim., 50, 2007 (1985). Yoshikuni N., Talanta, 43, 1949 (1996). Pilkington E.S., Smith P.R., Anal. Chim. Acta, 39, 321 (1967). Chirnside R.C. et al., Analyst, 88, 851 (1963). Pilipenko A.T., Voronina A.I., Nabivanets B.I., Zavod. Lab., 36, 273 (1970). Babkina T.A., Potapenko L.I., Zavod. Lab., 58, No 10, 6 (1992). Ryabchikov D.I., Lazarev A.I., Lazareva V.I., Zh. Anal. Khim., 19, 1110 (1964). Grekova I.M., Golik N.N., Serbinovich V.V., Zh. Anal. Khim., 38, 443 (1983). Girard L., Hubert J., Talanta, 43, 1965 (1996). Trojanowicz M., Pobozy E., Worsfold P.J., Anal. Lett., 25, 1373 (1992). Haukka S., Saastamoinen A.,Analyst, 117, 1381 (1992). Thomas O.,Analusis, 17, 221 (1989). Thomas O., Gallot S., Naffrechoux E., Fresenius'J. Anal. Chem., 338, 241 (1990). Ohls K., Riemer G., Z. Anal. Chem., 317, 774 (1984). Bennet H., Marshall K., Analyst, 88, 877 (1963). Patnaik U., Muralidhar J., Talanta, 42, 553 (1995).
Chapter 18. Cobalt Cobalt (Co, at. mass 58.93) occurs predominantly in the II oxidation state. In some complexes it is readily oxidizable to Co(III). The hydroxide Co(OH)2 is precipitated at pH -~7.5 and is insoluble in excess of NaOH. Cobalt forms ammine, cyanide, tartrate and EDTA complexes. Blue chloride complexes are formed in fairly concentrated chloride solutions.
18.1. Methods of separation and preconcentration 18.1.1. Extraction 1-Nitroso-2-naphthol, a popular spectrophotometric reagent for cobalt, is sometimes used in the preliminary extraction of Co from other metals before its determination [1-3]. Very small amounts of cobalt can be separated together with traces of other heavy metals by extraction with dithizone [4-6]. Within the pH range from 6 to 10 the extraction of cobalt is quantitative. The stability of Co(HDz)2 to dilute HC1 permits the separation of cobalt from other metals which form easily decomposed dithizonates (e.g., Cd, Zn, and Pb) [7]. Dithizone can be used for separating Co from Ni after the Ni has been converted into Ni(phen)32+ [5]. Thiocyanate complexes play an important role not only in the spectrophotometric determination of cobalt, but also in its separation from other metals [8-11 ]. The complex has been extracted with Alamine, TOPO [9], methyltrioctylamine [10], and DAM [ 11 ]. 18.1.2. Ion exchange and other methods When a solution of metals in 9 M HC1 is passed through a strongly basic anion-exchanger column, the chloride complexes of Co, Cu, Zn, and Fe(III) are retained by the resin, whereas Ni, Mn, and Cr are eluted since they do not form stable chloride complexes. Cobalt is eluted from the column with 4 M HC1. More dilute hydrochloric acid (e.g., 0.01 M) elutes Cu, Zn, and Fe(III) [ 12,13]. Cobalt has been separated from other metals by elution with hydrochloric acid mixed with acetone [14] or with tetrahydrofuran and glycol monomethyl ether [ 15]. Traces of cobalt can be precipitated as the hydroxide with La, A1, or Fe(III) as collectors [16,17]. Co(II) has been separated from Co(HI) by precipitating Co(II) with acetylacetone from ammoniacal medium [ 18]. A solid chelating material, 1-nitroso-2-naphthol supported on silica gel, provides a rapid and highly selective mean of separating traces of Co(H) from natural waters [19]. Open-cell polyurethane foam loaded with PAN azo reagent [20], and organic resins modified with nitroso-R salt have been used similarly [21,22].
18.2. Methods of determination The thiocyanate method is suitable for the determination of relatively large amounts of cobalt. Methods with nitroso-naphthols or nitroso-R salt are specific but not very sensitive. An example of a really sensitive method is that using the azo reagent, 5-Br-PADAP.
18.2.1. Thiocyanate method In concentrated solutions of K, Na or ammonium thiocyanate, CO 2+ ions produce a blue
168
18. Cobalt
colour which fades when the solution is diluted with water, owing to dissociation of the complex. The addition of acetone or any other water-miscible organic solvent (e.g., ethanol) which suppresses the dissociation of the complex, restores the blue colour to the solution. A complex with the formula Co(SCN)42- is predominant in the blue solution. In solutions with lower SCN- concentrations, and in the absence of acetone, pale pink Co(SCN) + exists. The colour intensity depends on the concentrations of SCN- and acetone. In solutions containing 50% acetone an increase in KSCN concentration above 10% gives no further increase of colour intensity. The acidity of the solution influences the colour intensity, so it should be kept constant (within 0.1-1 M HC1). The acidity of the solution affects the absorbance and should therefore be kept constant (between 0.1 and 1 M HC1) in the sample and the reference solutions. At )~max : 620 nm the molar absorptivity ~ (of a solution containing 10% of KSCN and 50% of acetone) is 1.9.103 (a = 0.032). Since iron(III) forms coloured complexes with SCN- ions, it interferes in the determination of cobalt. Larger quantities must be separated [e.g., by extraction, or by precipitation with Zn(OH)2]. Smaller amounts can be masked with fluoride, phosphate, or reduced to Fe(II) with ascorbic acid or SnCI2. Interfering elements include other metals which form coloured thiocyanate complexes (e.g., V, Bi, U, Cu, Mo, and W), and metals which give precipitates [Ag, Cu(I)] or consume thiocyanate ions to form colourless complexes ( e.g. Hg). Finally, ions which are themselves coloured (e.g., Ni and Cr) interfere when present at high concentrations. Copper(H) can be masked by means of thiosulphate or thiourea, and vanadium can be masked with tartaric acid. The cobalt(II) thiocyanate complex can be extracted with oxygen-containing solvents, such as a mixture of diethyl ether with isoamyl alcohol (1+1), MIBK, or acetylacetone [23,24]. The molar absorptivity, e, of the complex in the ether-isoamyl alcohol mixture is about 30% smaller than in the aqueous acetone media. The anionic cobalt(II) thiocyanate complex reacts with many organic bases to form ionassociates which can be extracted into CHC13, or other non-polar solvents. Organic reagents used for this purpose include DAM [25], TOA [26], triphenylsulphonium ion [27], or 2,4dichlorobenzyltriphenylphosphonium ion [28].
Reagents Potassium or ammonium thiocyanate, 50% solution. Standard cobalt solution: 1 mg/ml. Dissolve 4.7800 g of COSO4.7H20 in water containing 2 ml of conc. H2SO4, and dilute the solution with water to 1 litre. Alternatively use 2.6300 g of anhydrous cobalt sulphate prepared by ignition of the hydrous salt at --400~ The anhydrous salt dissolves more slowly. Thiosulphate-phosphate solution. Dissolve in water 40 g of NazSzO3.5H20 and 10 g of Na3PO4.12H20 and dilute the solution with water to 250 ml.
Procedure
Acetone variant. To the sample solution in a 25-ml standard flask containing less than 0.5 mg of Co, add enough HC1 to give a final concentration of 0.5 M. Add 5 ml of the thiocyanate solution. If a red colour appears (indicative of iron), add the ascorbic acid solution dropwise until the red colour is discharged, and then add 1 ml more. Add 12 ml of acetone, and dilute the solution with water to the mark. Measure the absorbance of the blue solution at 620 nm, using water as the reference.
169
18.2. Methods of determination
Extraction variant. Slightly acidify the sample solution containing not more than 0.5 mg of Co. Add 5 ml of the thiosulphate-phosphate solution and 5 ml of the thiocyanate solution, and adjust to pH 3.5-4.0. Transfer the solution to a separating funnel, and extract the complex with two 10-ml portions of a mixture of diethyl ether and isoamyl alcohol (1 + 1). Make up the combined ext