Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
I
II
The Practice ...
269 downloads
3645 Views
40MB Size
Report
This content was uploaded by our users and we assume good faith they have the permission to share this book. If you own the copyright to this book and it is wrongfully on our website, we offer a simple DMCA procedure to remove your content from our site. Start by pressing the button below!
Report copyright / DMCA form
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
I
II
The Practice of Clinical Echocardiography III
Second Edition Catherine M. Otto MD Professor of Medicine Acting Director, Division of Cardiology Director, Training Programs in Cardiovascular Disease Associate Director, Echocardiography Laboratory University of Washington Seattle, Washington
W.B. SAUNDERS COMPANY An Imprint of Elsevier Science Philadelphia•London•New York•St. Louis•Sydney•Toronto
Book Text
Pagina 1 di 2
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
IV
W.B. SAUNDERS COMPANY An Imprint of Elsevier Science The Curtis Center Independence Square West Philadelphia, Pennsylvania 19106 Library of Congress Cataloging-in-Publication Data The practice of clinical echocardiography / [edited by] Catherine M. Otto.—2nd ed. p. cm. Includes bibliographical references and index. ISBN 0-7216-9204-4 1. Echocardiography. I. Otto, Catherine M. [DNLM: 1. Echocardiography. WG 141.5.E2 P8942 2002] RC683.5.U5 C57 2002 616.1'207543-dc21 2001049709 Acquisitions Editor: Richard Zorab Production Editor: Robin E. Davis Production Manager: Mary Stermel Illustration Specialist: Rita Martello Book Designers: Catherine Bradish and Lynn Foulk THE PRACTICE OF CLINICAL ECHOCARDIOGRAPHY, Second Edition ISBN 0-7216-9204-4
Copyright © 2002, 1997 by W.B. Saunders Company. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Printed in the United States of America. Last digit is the print number: 9 8 7 6 5 4 3 2 1
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/2.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Contributors
V
Gerard P. Aurigemma MD Professor of Medicine and Radiology, University of Massachusetts Medical School; Director, Noninvasive Cardiology, University of Massachusetts Medical Center, Worcester, Massachusetts Quantitative Evaluation of Left Ventricular Structure, Wall Stress, and Systolic Function Thomas J. Benedetti MD Professor of Obstetrics and Gynecology, University of Washington School of Medicine, Seattle, Washington The Role of Echocardiography in the Diagnosis and Management of Heart Disease in Pregnancy Ann F. Bolger MD Associate Clinical Professor of Medicine, Division of Cardiology, University of California, San Francisco, School of Medicine; Director of Echocardiography, San Francisco General Hospital, San Francisco, California Aortic Dissection and Trauma: Value and Limitations of
Echocardiography Hans G. Bosch MSc Senior Staff Member, Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands Two-Dimensional Echocardiographic Digital Image Processing and Approaches to Endocardial Edge Detection Ian G. Burwash MD Professor of Medicine, University of Ottawa; Active Attending Staff, University of Ottawa Heart Institute, Ottawa, Ontario, Canada Indications, Procedure, Image Planes, and Doppler Flows Benjamin F. Byrd III MD Associate Professor of Medicine, Division of Cardiology, Vanderbilt University School of Medicine; Director, Echocardiography Laboratory, Vanderbilt University Medical Center, Nashville, Tennessee Maintaining Quality in the Echocardiography Laboratory Kwan-Leung Chan MD Professor of Medicine, University of Ottawa; Active Attending Staff, University of Ottawa Heart Institute, Ottawa, Ontario, Canada Indications, Procedure, Image Planes, and Doppler Flows Edmond W. Chen MD Fellow, Division of Cardiology, University of California, San Francisco, School of Medicine, San Francisco, California Echocardiographic Evaluation of the Patient with a Systemic
Embolic Event John S. Child MD Professor, University of California, Los Angeles, School of Medicine; Co-Chief, Division of Cardiology, Director, Ahmanson/UCLA Adult Congenital Heart Disease Center, UCLA Medical Center, Los Angeles, California Echocardiographic Evaluation of the Adult with Postoperative Congenital Heart Disease Joseph A. Diamond MD Assistant Professor of Medicine, Mount Sinai School of Medicine; Assistant Attending, The Mount Sinai Medical Center, New York, New York Hypertension: Impact of Echocardiographic Data on the Mechanism of Hypertension, Treatment Options, Prognosis, and Assessment of Therapy Pamela S. Douglas MD Tuchman Professor of Medicine; Head, Cardiovascular Medicine Section, University of Wisconsin Medical School, Madison, Wisconsin Quantitative Evaluation of Left Ventricular Structure, Wall Stress, and Systolic Function Thomas R. Easterling MD Associate Professor of Obstetrics and Gynecology, University of Washington School of Medicine, Seattle, Washington The Role of Echocardiography in the Diagnosis and Management of Heart Disease in Pregnancy Peter J. Fitzgerald MD, PhD Associate Professor of Medicine, Division of Cardiology, Stanford University School of Medicine, Stanford, California Intravascular Ultrasound: Histologic Correlation and Clinical
Applications Kirsten E. Fleischman MD, MPH Assistant Professor in Residence, University of California, San Francisco, School of Medicine; Attending Physician, University of California, San Francisco, Medical Center, San Francisco, California The Role of Echocardiographic Evaluation in Patients Presenting with Acute Chest Pain to the Emergency Room: Diagnosis, Triage, Treatment Decisions, Outcome Elyse Foster MD Professor of Clinical Medicine, University of California, San Francisco, School of Medicine; Director, Adult Echocardiography Laboratory, Moffitt-Long Hospital, San Francisco, California Echocardiography in the Coronary Care Unit: Management of Acute Myicardial Infarction, Detection of Complications, and Prognostic Implications
VI
William H. Gaasch MD Professor of Medicine, University of Massachusetts Medical School, Worcester, Massachusetts; Director, Cardiovascular Research, Lahey Clinic, Burlington, Massachusetts Quantitative Evaluation of Left Ventricular Structure, Wall Stress, and Systolic Function Edward F. Gibbons MD Assistant Clinical Professor of Medicine, University of Washington School of Medicine; Director of Echocardiography, Director of Inpatient Cardiology Services, Virginia Mason Medical Center, Seattle, Washington
Education and Training of Physicians and Sonographers John S. Gottdiener MD Professor of Medicine, State University of New York at Stony Brook, School of Medicine; Director, Noninvasive Cardiac Imaging, St. Francis Hospital, Roslyn, New York Hypertension: Impact of Echocardiographic Data on the Mechanism of Hypertension, Treatment Options, Prognosis, and Assessment of Therapy Brian P. Griffin MD Director, Cardiovascular Disease Training Program, The Cleveland Clinic Foundation, Cleveland, Ohio Echocardiography in Patient Selection, Operative Planning and Intraoperative Evaluation of Mitral Valve Repair Sheila K. Heinle MD Clinical Assistant Professor of Medicine, Division of Cardiology, The University of Texas Southwestern Medical Center, Dallas, Texas Quantitation of Valvular Regurgitation: Beyond Color Flow Mapping Mary Etta E. King MD Associate Professor of Pediatrics, Harvard Medical School; Director, Pediatric Echocardiography, Massachusetts General Hospital, Boston, Massachusetts Echocardiographic Evaluation of the Adult with Unoperated Congenital Heart Disease Tim Kinnaird MB Fellow in Cardiovascular Medicine, London Chest Hospital, London, United Kingdom Pericardial Disease
Katsuhiro Kitamura MD Research Fellow in Medicine, Stanford University Medical Center, Stanford, California Intravascular Ultrasound: Histologic Correlation and Clinical Applications Allan L. Klein MD Professor of Medicine, Ohio State University College of Medicine; Director, Cardiovascular Imaging Research, The Cleveland Clinic Foundation, Cleveland, Ohio Restrictive Cardiomyopathy: Diagnosis and Prognostic Implications Carol Kraft RDCS Lead Cardiac Sonographer, Virginia Mason Medical Center, Seattle, Washington Education and Training of Physicians and Sonographers Carolyn K. Landolfo MD Assistant Professor of Medicine, Duke University School of Medicine; Director, Adult Echocardiography, Duke University Medical Center, Durham, North Carolina The Role of Echocardiography in the Timing of Surgical Intervention for Chronic Mitral and Aortic Regurgitation Jannet F. Lewis MD Professor of Medicine, George Washington University Medical Center; Director of Echocardiography, George Washington University Hospital, Washington, D.C. Doppler and Two-Dimensional Echocardiographic Evaluation in Acute and Long-term Management of the Heart Failure Patient David T. Linker MD
Associate Professor of Medicine, Division of Cardiology; Adjunct Associate Professor of Bioengineering; University of Washington School of Medicine, Seattle, Washington Principles of Intravascular Ultrasound Warren J. Manning MD Associate Professor of Medicine and Radiology, Harvard Medical School; Section Chief, Non-invasive Cardiac Imaging, Beth Israel Deaconess Medical Center, Boston, Massachusetts The Role of Echocardiography in Atrial Fibrillation and Flutter Pamela A. Marcovitz MD Director, Clinical Cardiology Fellowship Program; Director, Echocardiographic Research, William Beaumont Hospital, Royal Oak, Michigan Exercise Echocardiography: Stress Testing in the Initial Diagnosis of Coronary Artery Disease and in Patients with Prior Revascularization or Myocardial Infarction Roy W. Martin PhD Research Professor, Department of Anesthesiology and Center for Bioengineering, Applied Physics Laboratory, University of Washington School of Medicine, Seattle, Washington Interaction of Ultrasound with Tissue, Approaches to Tissue Characterization, and Measurement Accuracy Thomas H. Marwick MD, PhD Professor of Medicine, Head of Section, University of Queensland Department of Medicine; Director of Echocardiography, Princess Alexandra Hospital, Brisbane, Queensland, Australia Stress Echocardiography with Nonexercise Techniques: Principles, Protocals, Interpretation, and Clinical Applications David J. Meier MD
Cardiology Fellow, University of Michigan Health System, Ann Arbor, Michigan The Role of Echocardiography in the Timing of Surgical Intervention of Chronic Mitral and Aortic Regurgitation
VII
Bradley I. Munt MD Clinical Instructor, The University of British Columbia Department of Medicine; Cardiologist, Providence Healthcare and St. Paul's Hospital, Vancouver, British Columbia, Canada Pericardial Disease Danielle Noll MD Department of Cardiology, Echocardiography, Medizinische Klinik, Klinikum Innentadt, Munich, Germany Myocardial Contrast Echocardiography: Methods, Analysis, and Applications Catherine M. Otto MD Professor of Medicine; Acting Director, Division of Cardiology; Director, Training Programs in Cardiovascular Disease; Associate Director, Echocardiography Laboratory, University of Washington School of Medicine, Seattle, Washington Aortic Stenosis: Echocardiographic Evaluation of Disease Severity, Disease Progression, and the Role of Echocardiography in Clinical Decision Making; The Role of Echocardiography in the Diagnosis and Management of Heart Disease in Pregnancy; Echocardiographic Findings in Acute and Chronic Pulmonary Disease Donald C. Oxorn MD
Associate Professor of Anesthesiology, Adjunct Associate Professor of Medicine, University of Washington School of Medicine, Seattle, Washington Monitoring Ventricular Function in the Operating Room: Impact on Clinical Outcome Abraham C. Parail MD Fellow in Cardiology, University of Wisconsin Medical School, Milwaukee, Wisconsin Aging Changes Seen on Echocardiography Robert A. Phillips MD, PhD Associate Professor of Medicine, Mount Sinai School of Medicine; Director, Department of Medicine, Lenox Hill Hospital, New York, New York Hypertension: Impact of Echocardiographic Data on the Mechanism of Hypertension, Treatment Options, Prognosis, and Assessment of Therapy Thomas R. Porter MD Associate Professor, University of Nebraska College of Medicine, Diagnostic Cardiac Ultrasound and Noninvasive Diagnostics, University of Nebraska Medical Center, Omaha, Nebraska Myocardial Contrast Echocardiography: Methods, Analysis, and Applications Harry Rakowski MD Professor of Medicine, Division of Cardiology, University of Toronto; Staff Cardiologist, Toronto General Hospital, Toronto, Ontario, Canada Echocardiography in the Evaluation and Management of Patients with Hypertrophic Cardiomyopathy Rita F. Redberg MD
Associate Professor of Medicine, Division of Cardiology, University of California, San Francisco, School of Medicine, San Francisco, California Echocardiographic Evaluation of the Patient with a Systemic Embolic Event Johan H. C. Reiber PhD Professor of Medical Imaging, Director, Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands Two-Dimensional Echocardiographi Digital Image Processing and Approaches to Endocardial Edge Detection Cheryl L. Reid MD Associate Professor of Medicine, University of California, Irvine College of Medicine; Director, Non-invasive Cardiology, University of California, Irvine, Medical Center, Orange, California Echocardiography in the Patient Undergoing Catheter Balloon Mitral Commissurotomy: Patient Selection, Hemodynamic Results, Complications, and Long-term Outcome Carlos A. Roldan MD Associate Professor of Medicine, University of New Mexico School of Medicine; Staff Cardiologist, Director, Echocardiography Laboratory, Veterans Affairs Medical Center; Staff Cardiologist, University of New Mexico Health Sciences Center, Albuquerque, New Mexico Echocardiographic Findings in Systemic Diseases Characterized by Immune-Mediated Injury Elizabeth W. Ryan MD
Research Fellow in Cardiology, Division of Cardiology, University of California, San Francisco, School of Medicine, San Francisco, California Aortic Dissection and Trauma: Value and Limitations of Echocardiography Kiran B. Sagar MD Professor of Cardiology and Medicine, University of Wisconsin Medical School, Milwaukee, Wisconsin Aging Changes Seen on Echocardiography Nelson B. Schiller MD Professor of Medicine, Radiology, and Anesthesia, University of California, San Francisco, School of Medicine; Director of Echocardiography, San Francisco Veterans Affairs Medical Center; Attending Physician, Cardiology, Echocardiography, and Adult Congenital Heart Disease, Moffitt-Long Hospital, San Francisco, California Clinical Decision Making in Endocarditis Ingela Schnittger MD Professor of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, California The Role of Echocardiography in the Evaluation of Patients After Heart Transplantation Douglas S. Segar MD Clinical Associate Professor of Medicine, Indiana University School of Medicine, Indiana Heart Institute, Indianapolis, Indiana The Digital Echocardiography Laboratory
VIII
David M. Shavelle MD
Interventional Cardiology Fellow, Good Samaritan Hospital, Los Angeles, California Aortic Stenosis: Echocardiographic Evaluation of Disease Severity, Disease Progression, and the Role of Echocardiography in Clinical Decision Making Florence H. Sheehan MD Research Professor of Medicine, Division of Cardiology, University of Washington School of Medicine, Seattle, Washington Quantitative Evaluation of Regional Left Ventricular Systolic Function; Three-Dimensional Echocardiography: Approaches and Applications Bruce K. Shively MD Associate Professor of Cardiology, Oregon Health and Science University; Co-Director, Echocardiography Laboratory, Oregon Health and Science University Hospital, Portland, Oregon Echocardiographic Findings in Systemic Diseases Characterized by Immune-Mediated Injury Mikel D. Smith MD Professor of Internal Medicine/Cardiology, University of Kentucky College of Medicine; Director, Adult Echocardiography Laboratory, Gill Cardiovascular Institute, Albert B. Chandler Medical Center, Lexington, Kentucky Left Ventricular Diastolic Function: Clinical Utility of Doppler Echocardiography A. Rebecca Snider MD Consultant, Pediatric Cardiology, Monmouth Junction, New Jersey General Echocardiographic Approach to the Adult with Suspected Congenital Heart Disease Mark R. Starling MD Professor of Internal Medicine,
Director of Cardiology Training Program, Associate Chief of Cardiology, University of Michigan Medical School; Chief, Cardiology Section, VA Ann Arbor Healthcare System, Ann Arbor, Michigan The Role of Echocardiography in the Timing of Surgical Intervention for Chronic Mitral and Aortic Regurgitation William J. Stewart MD Associate Professor of Medicine, Department of Cardiology, Staff Cardiologist, The Cleveland Clinic Foundation, Cleveland, Ohio Echocardiography in Patient Selection, Operative Planning, and Intraoperative Evaluation of Mitral Valve Repair Marcus F. Stoddard MD Professor of Medicine, University of Louisville School of Medicine; Director, Noninvasive Cardiology, University of Louisville Hospital, Louisville, Kentucky Echocardiography in the Evaluation of Cardiac Disease Due to Endocinopathies, Renal Disease, Obesity, and Nutritional Deficiencies Maran Thamilarasan MD Assistant Staff Cardiologist, The Cleveland Clinic Foundation, Cleveland, Ohio Restrictive Cardiomyopathy: Diagnosis and Prognostic Implications Christopher R. Thompson MD, CM Clinical Associate Professor of Medicine (Cardiology), Director, Echocardiography Laboratory, St. Paul's Hospital, Vancouver, British Columbia, Canada Pericardial Disease Aneesh V. Tolat MD
Clinical Fellow in Medicine, Harvard Medical School; Clinical Fellow in Cardiovascular Diseases, Beth Israel Deaconess Medical Center, Boston, Massachusetts The Role of Echocardiography in Atrial Fibrillation and Flutter Brandon R. Travis PhD School of Chemical Engineering, Georgia Institute of Technology, Atlanta, Georgia Fluid Dynamics of Prosthetic Valves Zian H. Tseng MD Cardiology Fellow, University of California, San Francisco, School of Medicine, San Francisco, California Echocardiography in the Coronary Care Unit: Management of Acute Myocardial Infarction, Detection of Complications, and Prognostic Implications Hannah A. Valantine MD Professor of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, California The Role of Echocardiography in the Evaluation of Patients After Heart Transplantation Samuel Wang MD Assistant Professor of Clinical Internal Medicine, University of California, Davis, School of Medicine; Attending Physician, University of California, Davis, Medical Center, Sacramento, California The Role of Echocardiographic Evaluation in Patients Presenting with Acute Chest Pain to the Emergency Room: Diagnosis, Triage, Treatment Decisions, Outcome E. Douglas Wigle MD Professor of Medicine, University of Toronto; Staff Cardiologist,
Toronto General Hospital, Toronto, Ontario, Canada Echocardiography in the Evaluation and Management of Patients with Hypertrophic Cardiomyopathy Selwyn P. Wong MD Cardiologist, Middlemore Hospital, Auckland, New Zealand Echocardiographic Findings in Acute and Chronic Pulmonary Disease Anna Woo MD Assistant Professor of Medicine, Division of Cardiology, University of Toronto; Staff Cardiologist, Toronto General Hospital, Toronto, Ontario, Canada Echocardiography in the Evaluation and Management of Patients with Hypertrophic Cardiomyopathy
IX
Feng Xie MD Research Assistant Professor, Cardiology, University of Nebraska Medical Center, Omaha, Nebraska Myocardial Contrast Echocardiography: Methods, Analysis, and Applications Paul G. Yock MD Professor of Medicine, Stanford University School of Medicine, Stanford, California Intravascular Ultrasound: Histologic Correlation and Clinical Applications Ajit P. Yoganathan PhD Regents Professor of Biomedical Engineering, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia
Fluid Dynamics of Prosthetic Valves Miguel Zabalgoitia MD Professor of Medicine; Director, Echocardiography Laboratory, University of Texas Health Science Center, San Antonio, Texas Echocardiographic Recognition and Quantitation of Prosthetic Valve Dysfunction William A. Zoghbi MD Professor of Medicine, Director of Echocardiography Research, Baylor College of Medicine; Associate Director, Echocardiography Laboratory, The Methodist Hospital, Houston, Texas Echocardiographic Recognition of Unusual Complications After Surgery on the Great Vessels and Cardiac Valves
X
XI
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/3.html/top
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Preface Echocardiography increasingly has become a key component in the routine evaluation of patients with suspected or known cardiovascular disease. As this technique has evolved and matured, the role of the echocardiographer has shifted from simply providing a description of images to providing an integrated assessment of echocardiographic data in conjunction with the other clinical data from each patient. In effect, echocardiography has become a specialized type of cardiology consultation. The information now requested by the referring physician includes not only the qualitative and quantitative interpretation of the echocardiographic images and Doppler flow data but also a discussion of how this information might affect clinical decision making. Specific examples include decisions regarding medical or surgical therapy (e.g., treatment of endocarditis, surgery for aortic dissection), optimal timing of intervention in patients with chronic cardiac diseases (e.g., valvular regurgitation, mitral stenosis), prognostic implications (e.g., heart disease in pregnancy, heart failure patients), and the possible need for and frequency of periodic diagnostic evaluation (e.g., congenital heart disease, the postoperative patient). This book reflects our role as clinicians with specialized expertise in echocardiography and is of value to cardiology fellows pursuing advanced training in echocardiography, cardiologists in clinical practice, researchers using echocardiographic techniques, and other individuals using echocardiographic approaches in the clinical setting (including anesthesiologists, radiologists, emergency medicine physicians, and obstetricians), as well as to cardiac sonographers, cardiovascular technologists, and nursing professionals.
Each chapter provides an advanced level of discussion, written by an expert in the field, building upon the basic material in the Textbook of Clinical Echocardiography (C. M. Otto, 2nd Edition, WB Saunders, Philadelphia, 2000). The emphasis is on optimal data acquisition, results of recent studies, quantitative approaches to data analysis, potential technical limitations, and areas of active research, in addition to a detailed discussion of the impact of echocardiographic data on patient management. Tables, line drawings, echocardiographic images, and Doppler tracings are used to summarize and illustrate key points. In this Second Edition, the text has been revised to reflect recent advances, illustrations and tables have been updated, and new references have been added to each chapter. The book is organized into sections based on major diagnostic categories. In this new edition, an introductory section on transesophageal echocardiography has been added. Chapters include basic principles of transesophageal imaging, monitoring of ventricular function in the operating room, and a discussion of echocardiographic evaluation of aortic dissection and trauma. Other detailed information on the role of transesophageal echocardiography is integrated into subsequent chapters, which are organized by disease categories. The next section focuses on the left ventricle, with chapters spanning the spectrum from emerging new techniques (e.g., myocardial contrast echocardiography, automated edge detection, tissue characterization, three-dimensional echocardiography) to critical appraisals of quantitative techniques (e.g., left ventricular geometry and systolic function, evaluation of regional function, and assessment of diastolic function). The section on ischemic heart disease includes chapters on the role of echocardiography in the emergency room and coronary care unit, stress echocardiography (exercise and nonexercise), and the basic principles, instrumentation, and clinical applications of intravascular ultrasound in patients with coronary artery disease. The critical role that echocardiography now plays in management of patients with valvular heart disease is evident in a section of chapters on technical aspects of echocardiographic evaluation, optimal timing of surgery and periodic evaluation of patients with valvular regurgitation, management of patients undergoing balloon mitral commissurotomy, clinical decision making in patients with endocarditis, evaluation of disease severity, progression in valvular aortic stenosis, and evaluation of prosthetic valves. The following clinically oriented sections bring together data from both the
echocardiographic and general cardiology literature to discuss the role of echocardiography in patients with cardiomyopathies (heart failure, hypertrophic cardiomyopathy, restrictive cardiomyopathy, and the posttransplant patient) and pericardial disease, pregnant patients with cardiac disease, and a wide range of other vascular and systemic diseases that lead to cardiac dysfunction (hypertension, aortic dissection, pulmonary disease, systemic immune-mediated diseases, renal disease, aging, systemic embolic events, and cardiac arrhythmias). In recognition of the increasing number of adult patients presenting with congenital heart disease, either as a new diagnosis or following prior surgical procedures, three chapters are devoted to this topic. In addition, a new section has been added on the echocardiography laboratory to address issues that increasingly affect our clinical practice, including education and training of echocardiographers, quality improvement in the echocardiography laboratory, and the transition to a digital laboratory. It is hoped that this book will provide the needed background to support and supplement clinical experience and expertise. Of course, competency in the acquisition and interpretation of echocardiographic and Doppler data depends on appropriate clinical education and training as detailed in accreditation requirements for both physicians and technologists, and as recommended by professional societies including the American Society of Echocardiography, the American College of Cardiology, and the American Heart Association. I strongly support these educational requirements and training recommendations; XII
readers of this book are urged to review the relevant documents. In addition, there continue to be advances both in the the technical aspects of image and flow data acquisition and in our understanding of the clinical implications of specific echocardiographic findings. This book represents our knowledge base at one point in time; readers should consult the current literature for the most up-to-date information. Although an extensive list of carefully selected references is provided with each chapter, the echocardiographic literature is so robust that it is impractical to include all relevant references; the reader can use an online medical literature search if an all-inclusive listing is desired. Catherine M. Otto MD
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Acknowledgments
XIII
Sincere thanks are due to the many individuals who made this book possible. Primary recognition goes to the chapter contributors who provided scholarly, thoughtful, and insightful discussions and who integrated the clinical and echocardiographic information into a format that benefits our readers. The support staff at each of our institutions deserves our appreciation for manuscript preparation and providing effective communication, with special thanks to Sharon Kemp and Bev Bubela. The many research subjects who contributed to the data on which our current understanding is based certainly are worthy of our appreciation. The cardiac sonographers at the University of Washington Medical Center (Rachel Elizalde, RDCS; Michelle C. Fujioka, RDMS; Carolyn J. Gardner, RDCS; Caryn D'Jang, RDCS; Scott Simicich, RDCS; David Stolte, RDCS; Rebecca G. Schwaegler, RDMS; Erin Trent, RDCS; and Todd R. Zwink, RDMS) merit acknowledgment. In addition, gratitude is due to Richard Zorab and the production team at W.B. Saunders. Finally, I thank my family for their constant encouragement and support.
XIV
XVIII
NOTICE Medicine is an ever-changing field. Standard safety precautions must be followed, but as new research and clinical experience broaden our knowledge, changes in treatment and drug therapy may become necessary or appropriate. Readers are advised to check the most current product information provided by the manufacturer of each drug to be administered to verify the recommended dose, the method and duration of administration, and contraindications. It is the responsibility of the treating physician, relying on experience and knowledge of the patient, to determine dosages and the best treatment for each individual patient. Neither the Publisher nor the editor assumes any liability for any injury and/or damage to persons or property arising from this publication. THE PUBLISHER
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/5.html/top
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Section 1 - Transesophageal Echocardiography
1
Chapter 1 - Indications, Procedure, Image Planes, and Doppler Flows Ian G. Burwash MD Kwan-Leung Chan MD
Transesophageal echocardiography (TEE) has become a valuable diagnostic imaging modality for the dynamic assessment of cardiac anatomy and function. Since the initial description of esophageal echocardiography in 1976,[1] the potential role and utility of TEE in the evaluation of diseases of the heart and great vessels have expanded to involve all aspects of cardiac disease. The close proximity of the esophagus to the heart and great vessels provided the echocardiographer with an easily accessible window with the potential for excellent visualization of cardiac structures, avoiding the intervening lung and chest wall tissues that limit transthoracic imaging. The potential of TEE to provide a valuable imaging tool became widely recognized in the 1980s with advancements in TEE probe technology, including the availability of single-plane phased array transducers and the addition of color flow and continuous wave Doppler imaging technology. TEE does not supplant transthoracic echocardiography
(TTE), however; it is a complementary imaging modality with its own strengths and weaknesses. The 2
introduction of biplane TEE transducers in the late 1980s and multiplane transducers in the 1990s has resulted in a further expansion of potential diagnostic applications. Perhaps the best evidence of TEE's diagnostic utility and value in patient management is the widespread use of this technology. TEE is found in the inpatient and outpatient ambulatory setting, in the operating room, in the intensive care unit, and in the emergency department. Currently, TEE accounts for approximately 5% to 10% of all echocardiography studies performed. The indications and utility of TEE will likely expand in the future with new technologic advancements such as three-dimensional echocardiography.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/6.html/top
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Performance of Transesophageal Echocardiography Transesophageal echocardiography is a semi-invasive procedure that should be performed only by a properly trained physician who understands the indications for and potential complications of the procedure. Both technical and cognitive skills are required for the competent performance and interpretation of TEE studies (Table 1-1) , and guidelines on training have been published.[2] The physician should be assisted by an experienced sonographer whose tasks are to ensure that optimal images are obtained by adjusting the controls of the echocardiographic system and to ensure safety by monitoring the responses of the patient during the procedure. Although family members or friends are usually not allowed in the room when the procedure is being performed, there are situations in which their presence can be helpful. The presence of a parent can have a calming effect when one is dealing with an apprehensive teenager. A friend or a relative who speaks the same language can relieve much of the anxiety when dealing with an anxious patient who is not fluent in English. Transesophageal echocardiography should be performed in a spacious room that can comfortably accommodate a stretcher. The room should be equipped with an oxygen outlet and suction facilities. A pulse oximeter should be available, to be used mainly in cyanotic patients and patients with severe lung disease. The TEE probe should be carefully examined prior to each use. In addition to visual inspection, it is important to palpate the probe, particularly the flexion portion, to ensure that there is no unusual wear and tear of the probe.[3] Stretching of the steering cables may result in increased flexibility and mobility of the probe tip with buckling of the probe tip within the esophagus.[4] This phenomenon is associated with a poor TEE image and resistance to probe withdrawal. The probe should be advanced into the stomach and straightened by retroflexion of the extreme antiflexed probe tip. We have also detected perforation of the TEE probe sheath by a ruptured steering cable and recommend inspection of the casing for any protruding wires prior to probe insertion.[3] The flexion controls
need to be tested on a regular basis. Anterior flexion should exceed 90 degrees, and right and left flexion should approach 90 degrees. TABLE 1-1 -- Cognitive and Technical Skills Required for the Performance of Transesophageal Echocardiography (TEE) Cognitive Skills Knowledge of appropriate indications, contraindications, and risks of TEE Understanding of differential diagnostic considerations in each clinical case Knowledge of physical principles of echocardiographic image formation and blood flow velocity measurement Familiarity with the operation of the ultrasonographic instrument, including the function of all controls affecting the quality of the data displayed Knowledge of normal cardiovascular anatomy, as visualized tomographically Knowledge of alterations in cardiovascular anatomy resulting from acquired and congenital heart diseases Knowledge of normal cardiovascular hemodynamics and fluid dynamics Knowledge of alterations in cardiovascular hemodynamics and blood flow resulting from acquired and congenital heart diseases Understanding of component techniques for general echocardiography and TEE, including when to use these methods to investigate specific clinical questions Ability to distinguish adequate from inadequate echocardiographic data and to distinguish an adequate from an inadequate TEE examination Knowledge of other cardiovascular diagnostic methods for correlation with TEE findings Ability to communicate examination results to patient, other health care professionals, and medical record Technical Skills Proficiency in performing a complete standard echocardiographic examination, using all echocardiographic modalities relevant to the case Proficiency in safely passing the TEE transducer into the esophagus and
stomach and in adjusting probe position to obtain the necessary tomographic images and Doppler data Proficiency in correctly operating the ultrasonographic instrument, including all controls affecting the quality of the data displayed Proficiency in recognizing abnormalities of cardiac structure and function as detected from the transesophageal and transgastric windows, in distinguishing normal from abnormal findings, and in recognizing artifacts Proficiency in performing qualitative and quantitative analysis of the echocardiographic data From Pearlman AS, Gardin JM, Martin RP, et al: J Am Soc Echocardiogr 1992;5:187–194. Preparation of Patient Patients should be contacted at least 12 hours before the procedure and instructed to fast for at least 4 hours before the procedure. They are informed that they should be accompanied, because they will not be able to drive or return to work for several hours owing to the lingering effect of sedation. On the day of the study, the procedure is explained in greater detail, and informed consent is obtained. Patients are told to expect mild abdominal discomfort and gagging following the insertion of the probe and are reassured that these responses are transient. A 20-gauge intravenous cannula is then inserted for administration of medications and contrast agents, if necessary. Lidocaine hydrochloride spray is routinely used for topical anesthesia, which should cover the posterior pharynx and the tongue. We usually use diazepam 2 to 10 mg intravenously 3
for sedation.[5] Midazolam at 0.05 mg/kg, with a total dose between 1 and 5 mg, can also be used. Sedation is used in about 85% of our patients and should be more sparingly used in elderly patients, because they tend to be more stoic and the effect of sedation is more likely prolonged. On the other hand, sedation is essential in young anxious patients and when the study is expected to be protracted. We aim for light sedation so that at the end of the procedure the patients are awake and can leave with an escort. Heavy sedation is needed in situations in which blunting the hemodynamic responses to the procedure is desirable. One obvious example is a patient undergoing TEE for suspected aortic
dissection.[6] It has not been our practice to use anticholinergic agents such as glycopyrrolate to decrease salivation. In the rare circumstances in which there is excessive salivation, it is usually adequate to simply instruct the patient to let the saliva dribble onto the towel placed under the chin, or the saliva can be removed by intermittent suction. Bacteremia is not a significant risk in TEE, and we do not use antibiotic prophylaxis to prevent endocarditis even in patients with prosthetic heart valves.[7] [8] Esophageal Intubation We perform the TEE study with the patient in the left decubitus position. The physician, the sonographer, and the echocardiographic system are all positioned on the left-hand side of the patient.[5] Artificial teeth or dentures are routinely removed. The flexion controls should be unlocked to allow for maximum flexibility of the probe when it is being inserted. The patient's head should be in a flexed position. The tip of the probe is kept relatively straight and gently advanced to the back of the throat. It should be maintained in a central position, because deviation to either side increases the likelihood that it may become lodged in the piriform fossa. The operator can facilitate this process by inserting one or two fingers into the patient's oropharynx to direct the path of the probe. Gentle pressure is exerted and the patient is instructed to swallow. The swallowing mechanism helps guide the probe into the esophagus. In older patients, cervical spondylosis with prominent protrusion into the posterior pharynx can create difficulty with passage of the probe.[5] Manually depressing the back of the tongue provides more room, allowing the TEE probe to assume a less acute angle and facilitating the intubation of the esophagus. If significant resistance is encountered when the probe is advanced, it is prudent to withdraw the probe and then initiate a new attempt. Esophageal intubation is more difficult with the multiplane probe than with the smaller monoplane and biplane probes.[9] [10] The latter can be used, if available, when esophageal intubation cannot be achieved with a multiplane probe. In experienced hands, the rate of failure of esophageal intubation should be less than 2%.[5] [9] [11]
A bite guard should always be used, except in edentulous patients. Our practice is to put it between the patient's teeth after the TEE probe has been successfully passed into the esophagus. Patients with a very sensitive pharynx may close their mouths involuntarily during esophageal intubation. In these patients, it is safer to insert the bite guard before the insertion of
the TEE probe. The patient should be instructed to keep the guard between the teeth throughout the procedure, and regular checks should be made to ensure that it is in the proper position to prevent damage to the probe or injury to the patient. Even when the probe is inserted without difficulties, it is not uncommon for the patient to develop nausea with or without mild retrosternal or abdominal discomfort. We find it useful to pause for 10 to 15 seconds to allow these symptoms to subside before proceeding with echocardiographic imaging. Our practice is to start with images acquired from the esophagus before advancing the probe into the stomach for the gastric views. The gastroesophageal sphincter is usually reached when the probe is advanced 40 cm from the teeth. Gentle pressure is all that is required to advance the probe through the gastroesophageal sphincter. The patient may again experience nausea and mild discomfort, and it may be advisable to pause momentarily for these symptoms to subside. Imaging of the proximal descending thoracic aorta and aortic arch is generally reserved for the end of the study, because the probe needs to be positioned in the upper esophagus and the patient is generally more aware of the probe at this position and tends to have more discomfort and gagging. Inadvertent passage of the probe into the trachea can occur, particularly in deeply sedated patients. The development of stridor and incessant cough should alert the operator of this possibility. Furthermore, it would be difficult to advance the probe beyond 30 cm from the teeth and the image quality is usually poor.[5] In patients on mechanical ventilation, esophageal intubation is more difficult. We usually introduce the probe with the patient lying supine, because the airway is protected and aspiration is unlikely. The probe is positioned behind the endotracheal tube and gently advanced. It is helpful to have the patient's mandible pulled forward when the probe is being advanced. If there is undue resistance at about 25 to 30 cm from the teeth, slight deflation of the cuff of the endotracheal tube can be considered to ease the passage of the probe. We do not usually remove the gastric tube, which can be used as a guide to help in the proper positioning and passage of the TEE probe. In a minority of intubated patients, successful esophageal intubation may be achieved only with direct laryngoscopy. Image Format There is no general agreement on how the imaging planes should be
displayed. Our preference is to orient the images such that the right-sided structures are on the left side of the screen and the left-sided on the right. The apex of the imaging plane with the electronic artifact is at the top of the screen. Thus, in the longitudinal views, superior structures are to the right of the screen and the inferior to the left.[12]
4
TABLE 1-2 -- Standard Imaging Planes with Multiplane Transesophageal Echocardiography (TEE) at the University of Ottawa Heart Institute
Imaging View Basal
Fourchamber
Standard Imaging Plane Aortic valve
Angle of Imaging Array (degrees) 0–60
Atrial septum
90–120
Pulmonary bifurcation
0–30
Left ventricle
0–180
Mitral valve
0–180
Left ventricular outflow tract
120–160
Transgastric Left ventricle Mitral valve
0–150 0–150
Main Cardiac Structures Aortic valve, coronary arteries, left atrial appendage, pulmonary veins Fossa ovalis, superior vena cava, inferior vena cava Pulmonic valve, main and right pulmonary arteries, proximal left pulmonary artery Left ventricle (regional and global function), right ventricle, tricuspid valve Anterior and posterior mitral leaflets, papillary muscles, chords Aortic valve, ascending aorta, left and right ventricular outflow tracts, pulmonic valve, main pulmonary artery Left ventricle, right ventricle, tricuspid valve Anterior and posterior mitral leaflets, papillary muscles,
Aortic
Coronary sinus Descending thoracic aorta Aortic arch
0
chords Coronary sinus, tricuspid valve
0
Entire descending thoracic aorta
90
Aortic arch, arch vessels, left pulmonary artery
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/7.html/top
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Standard Imaging Planes Advances in TEE transducer technology have culminated in the development of the multiplane probe capable of two-dimensional and color flow imaging in multiple planes. The imaging plane can be steered electronically from 0 to 180 degrees by means of a pressure-sensitive switch, providing views unattainable by monoplane and biplane probes. The following discussion focuses only on standard imaging views routinely performed at the University of Ottawa Heart Institute using multiplane TEE (Table 1-2) . These views are considered "standard" because they have important clinical relevance and can be obtained in most patients with specific imaging planes. Four basic maneuvers are used to obtain specific tomographic views with TEE.[13] The first relates to the positioning of the probe by advancement or withdrawal of the probe. Although this is a simple maneuver, it is the most crucial, and the imaging views can be conveniently categorized according to the location of the TEE probe within the esophagus or stomach (Fig. 11) . The second maneuver involves rotation of the probe from side to side. This is particularly useful when using longitudinal imaging planes, which provide a better demonstration of the continuity between vertically aligned structures such as the superior vena cava and the arch vessels.[12] [13] Steering the imaging plane using the pressure-sensitive switch is the third maneuver to obtain different tomographic views. The ability to image cardiac structures from 0 to 180 degrees not only enhances understanding of cardiac anatomy but also provides a ready means for three-dimensional reconstruction. [14] [15] The fourth maneuver involves manipulation of the anterior-posterior and right-left flexion control knobs. The availability of a steerable imaging plane has drastically reduced the need to use the flexion knobs, but there are situations in which these knobs play a crucial role in obtaining proper tomographic views.[10] [13] The versatility of multiplane TEE provides an almost infinite number of
imaging planes. In our experience, it is useful to categorize them into four groups: basal, four-chamber, transgastric, and aortic views (see Fig. 1-1) . Table 1-2 summarizes the standard imaging planes and the cardiac structures evaluated in these four groups of views. Basal Views The basal group of views is obtained with the TEE probe located in the midesophagus. The base of the heart, Figure 1-1 Diagram showing the transesophageal echocardiography transducer locations for the four standard imaging views: basal (A), fourchamber (B), transgastric (C), and aortic (D).
5
particularly the aortic valve, is well seen. The relationship of the two great arteries can be very well defined and followed cephalad to at least the level of the pulmonary bifurcation. Beyond this level, the interposing trachea make imaging impossible. Three tomographic planes are found to be particularly useful and are routinely performed at our laboratory. Aortic Valve
A short-axis view of the aortic valve can be obtained with the probe at about 30 to 35 cm from the teeth. The left coronary cusp often appears to have nodular thickening if the aortic valve is cut obliquely, which is often the case at 0 degrees.[12] Steering the imaging plane to 30 to 60 degrees should eliminate this artifact by providing an optimal short-axis view of the aortic valve (Fig. 1-2) . [13] A slight pull-back of the transducer should allow visualization of both the left and right coronary arteries. The left coronary artery can be followed to its bifurcation into the left anterior descending and circumflex arteries (Fig. 1-3) . The right coronary artery is more difficult to display, and usually only the proximal 2 to 3 cm is seen (Fig. 14) . Other structures well seen in this view are the left atrial appendage and the left pulmonary veins. The partition between these structures can be quite bulbous and should not be confused with an abnormal intracardiac mass (see Fig. 1-4) .[16] Rotating the probe to the right should reveal the right pulmonary veins.
We like the horizontal plane in imaging the four pulmonary veins. The left and right pulmonary veins are imaged separately. It is difficult to image the upper and lower pulmonary veins, left or right, in the same view because the veins are not located in the same plane with the lower pulmonary veins posterior and inferior to the upper pulmonary veins.[17] When one pulmonary vein is identified, a slight translational movement of the probe should bring out the other, because the orifices of the upper and Figure 1-2 The aortic valve was imaged with the imaging plane at about 60 degrees, showing the three cusps in systole. LA, left atrium; RA, right atrium; RV, right ventricle.
Figure 1-3 The left coronary artery (arrows) was imaged at 0 degrees. Ao, aorta; LA, left atrium.
lower pulmonary veins are in close proximity. The lower pulmonary veins run horizontal to the imaging plane, whereas the upper veins are more anterior and at an obtuse angle, making them more suitable for Doppler assessment. The right and left atrial appendages wrap around the great arteries anteriorly. The left atrial appendage is more prominent and can consist of multiple lobes.[18] A comprehensive interrogation using multiple imaging planes should be performed to exclude left atrial appendage thrombus in the appropriate clinical setting. The right atrial appendage is smaller and triangular in shape (Fig. 1-5) . The endocardial surfaces of both appendages are corrugated and should not be confused with small thrombi.[16] A long-axis view of the aorta can be achieved with the imaging plane at about 120 degrees. A more rightward imaging plane, such as 150 degrees, may be Figure 1-4 The proximal right coronary artery (small arrows) and the bulbous partition between the left atrial appendage and the left upper pulmonary vein (large arrow) are demonstrated. Ao, aorta; LA, left atrium.
6
Figure 1-5 The atrial septum was preferentially imaged using the longitudinal plane to demonstrate its relation with the superior vena cava (SVC). LA, left atrium; RA, right atrium; RAA, right atrial appendage.
needed if the ascending aorta is dilated and tortuous. This view allows the visualization of a longer length of the ascending aorta and thus significantly reduces the blind spot caused by the interposing trachea. Atrial Septum
We prefer to image the atrial septum using the longitudinal plane at 90 to 120 degrees. The fossa ovalis, which is the thinnest part of the atrial septum, and the continuity of the superior vena cava with the right atrium are very well demonstrated in this view (see Fig. 1-5) . This view is particularly valuable in demonstrating the sinus venosus atrial septal defect, which is usually located just inferior to the entrance of the superior vena cava.[19] [20] The foramen ovale, if present, is located at the superior aspect of the fossa ovalis and is readily seen in this view. It is important to advance the probe to the level of the inferior vena cava so as not to neglect the inferior aspect of the atrial septum.[21] Careful sweep of the atrial septum with left-right rotation is needed to visualize the entire atrial septum. Continuous rotation from right to left will sequentially demonstrate the left ventricular outflow tract and the right ventricular outflow tract. Rotating the probe to the right shows the right upper pulmonary vein and provides parallel alignment for Doppler assessment. Pulmonary Bifurcation
The pulmonary bifurcation view is achieved by withdrawal of the probe with the imaging plane at 0 degrees. The pulmonic valve and main pulmonary artery are best seen slightly superior to the aortic valve (Fig. 16) . The pulmonic valve is thinner than the aortic valve and is usually difficult to image in a true cross section. Further slight withdrawal allows imaging the pulmonary bifurcation. The entire length of the right pulmonary artery but only the very proximal portion of the left pulmonary artery can be seen. The right pulmonary artery can usually be followed to its first bifurcation by rotation of the probe rightward, but this maneuver is better performed with the longitudinal plane at 90 degrees. Gradual rotation from left to right provides good visualization in cross section of the entire right pulmonary artery and its first bifurcation. This is an important view in
the detection of proximal pulmonary emboli.[22] [23] Four-Chamber Views Four-chamber views are obtained with the transducer within the middle to lower esophagus. It is difficult to image the left ventricle in its true long axis. Excessive anterior flexion should be avoided to prevent foreshortening of the ventricles. Indeed, to optimize visualization of the left ventricle, it is advisable to withdraw the probe slightly and at the same time attempt gentle retroflexion while maintaining adequate contact between the imaging surface and the esophagus. In the setting of a dilated and unfolded aorta, rotating the imaging plane to about 20 to 30 degrees may be necessary to obtain the four-chamber view without the aorta obscuring the tricuspid valve and part of the right ventricle. Left Ventricle
The inferior septum and anterolateral wall are usually seen in the fourchamber view (Fig. 1-7) . The left ventricular apex is difficult to visualize, particularly in patients with a dilated left ventricle. In addition to retroflexion, rightward flexion can often be helpful to minimize foreshortening of the left ventricle. Far-field imaging can be improved by decreasing the transmission frequency. A continuous sweep from 0 to 180 degrees should be performed to examine the different left ventricular segments Figure 1-6 The bifurcation of the main pulmonary artery (MPA) into the right (RPA) and left (LPA) pulmonary arteries was imaged using the transverse plane. Ao, aorta.
7
Figure 1-7 The four-chamber view showing the left ventricle (LV) and mitral valve. LA, left atrium; RA, right atrium; RV, right ventricle.
so as to have a comprehensive assessment of left ventricular global and regional function (Fig. 1-8) .
Mitral Valve
The mitral valve is well seen using the four-chamber view, but the depth of the imaging plane should be reduced to enhance the resolution of the image ( see Fig. 1-7 and Fig. 1-8 ). To identify the individual scallops of the anterior and posterior mitral leaflets, a careful sweep from 0 to 180 degrees should be made. The technique of visualizing specific scallops of the mitral leaflets have been published,[24] but patient-to-patient variation should be kept in mind. The presence of a good long-axis view of the aortic valve and proximal ascending aorta, usually at Figure 1-8 The left ventricle and mitral valve can be comprehensively assessed by a continuous sweep of the imaging plane, which was about 100 degrees in this example. LA, left atrium; LV, left ventricle.
120 degrees, is a good indication that the middle scallops of both the anterior and the posterior mitral leaflets are imaged and provides the internal reference for the analysis of the other imaging planes. Both papillary muscles can be imaged but usually not in the same plane. The subvalvular chords are seldom completely imaged because they are frequently obscured by the mitral leaflets. The morphologic information obtained from this view should be corroborated by the short-axis view of the mitral valve obtained from the transgastric view, which also allows a better assessment of the subvalvular structures, including the papillary muscles and chords. Four-chamber views are ideal for the assessment of mitral regurgitation in relation to the number of regurgitant jets, the direction of the regurgitant jets, and the severity of regurgitation. [25] [26] Left Ventricular Outflow Tract
We like to image the left ventricular outflow tract at 120 to 160 degrees, because the outflow tract has a horizontal alignment in this plane that may allow optimal imaging even in the setting of a prosthetic aortic valve (Fig. 1-9) . The opening and closing of the aortic valve as well as the presence or absence of aortic regurgitation can be well visualized. The proximal ascending aorta is present in this view. A slight withdrawal of the probe will allow more of the ascending aorta to be visualized (Fig. 1-10) . A slight rotation to the left will show the right ventricular outflow tract with the thin pulmonic valve. Both the motion of the pulmonic valve and the presence or absence of pulmonic regurgitation can be adequately assessed
using this view. Transgastric Views There is slight resistance during the passage of the TEE probe through the gastroesophageal junction, and the Figure 1-9 The left ventricular outflow tract was well seen with the imaging plane at about 120 degrees. Ao, aorta; LA, left atrium; LV, left ventricle; RVOT, right ventricular outflow tract.
8
Figure 1-10 Slight withdrawal of the probe relative to the probe position used to acquire the image shown in Figure 1-9 showed the right pulmonary artery (RPA) in short axis and more of the ascending aorta (Ao). LA, left atrium.
appearance of the liver is a clear indication that the probe is in the stomach. Anterior flexion, often with leftward rotation and flexion, is required to achieve good contact between the imaging surface and the gastric wall. Extreme anterior flexion with further advancement of the probe can sometimes produce images similar to the five-chamber views obtained from the subxiphoid surface approach. Left Ventricle
Multiple cross sections of the left ventricle can usually be obtained using the transgastric approach ( Fig. 1-11 and Fig. 1-12 ). These are the views commonly used in the intraoperative assessment of left ventricular function.[24] Optimization of the short-axis views of the left ventricle Figure 1-11 Transgastric short-axis view of the left ventricle (LV) at the papillary muscle level.
Figure 1-12 Transgastric long-axis view of the left ventricle (LV) with
visualization of the apex.
can be achieved with leftward rotation accompanied by leftward flexion. To visualize the left ventricular apex, gentle advancement of the probe is required together with slight retroflexion. In our experience, the short-axis view of the left ventricular apex can be obtained in about 60% of cases. Another way to visualize the left ventricular apex is to use the longitudinal plane at about 90 degrees (see Fig. 1-12) . Careful lateral rotation can be used to obtain comprehensive regional assessment of the left ventricle. Leftward rotation of this imaging plane can yield a good alignment with the left ventricular outflow tract and aortic valve to allow accurate measurement of the transaortic pressure gradients in the setting of aortic stenosis (Fig. 1-13) . [27] The right ventricle can be seen with rightward rotation of the probe. Both short- and long-axis views of the tricuspid valve are achievable, although Figure 1-13 Transgastric transesophageal echocardiography approach to assess the severity of aortic stenosis using continuous wave Doppler echocardiography.
9
the tricuspid valve and its papillary muscles are better assessed with the long-axis plane. Mitral Valve
The mitral valve can be best assessed using the horizontal imaging plane with the transducer brought up to near the gastroesophageal junction (Fig. 1-14) . Anterior flexion and leftward flexion are usually required to optimize this view. Adjusting the imaging plane to about 20 degrees will help to bring out the lateral commissure. This view provides unambiguous assessment of the individual scallops of both the anterior and posterior mitral leaflets and thus should be attempted in all patients with myxomatous mitral valve degeneration. In our experience, this view is achievable in about 70% of patients. Both the papillary muscle and chords can be demonstrated, and the continuity between these structures and the mitral leaflets is best seen in the long-axis plane. Coronary Sinus
The coronary sinus comes into view when the probe is withdrawn to be near the gastroesophageal junction and the flexion knobs are in relatively neutral positions (Fig. 1-15) . This view can also be achieved by retroflexion with the probe in the lower esophagus. The coronary sinus is seen as a vascular structure located posterior to the left ventricle at the atrioventricular groove draining into the right atrium. The tricuspid valve can be visualized to the right and anterior. A dilated coronary sinus should raise the possibility of the presence of a persistent left superior vena cava, which is the most common cause. Leftward rotation while following the coronary sinus may sometimes demonstrate this anomalous vein. In the esophageal views, the left superior vena cava is usually sandwiched between the left atrial appendage and the left upper pulmonary vein.[28] Figure 1-14 The mitral valve was demonstrated in the short axis showing the anterior (arrows) and posterior (arrowheads) mitral leaflets.
Figure 1-15 The coronary sinus (CS) was demonstrated with the probe at the gastroesophageal junction. LV, left ventricle; RV, right ventricle.
Aortic Views The thoracic aorta is well assessed by TEE because of its close proximity to the esophagus. Descending Thoracic Aorta
The best way to assess the descending thoracic aorta is to use the horizontal imaging plane with the transducer rotated leftward and posterior, followed by slow withdrawal from the level of the diaphragm to the aortic arch (Fig. 1-16) .[16] Because of the relationship between the Figure 1-16 The descending aorta was imaged in the short axis to allow good visualization of entire circumference.
10
Figure 1-17 The aortic arch (AA) was imaged using the longitudinal plane, showing the origin of the left subclavian artery (LSA).
esophagus and the aorta, slight rotational adjustment is required to visualize the entire circumference of the aortic wall as the probe is slowly withdrawn.[29] If the aorta is dilated or tortuous, proper short-axis views of the descending aorta will require adjustment of the imaging plane by 0 to 90 degrees. Aortic Arch
The longitudinal imaging plane at 90 degrees is preferred in imaging the aortic arch because it allows visualization of the entire circumference of the aorta (Fig. 1-17) .[29] Anterior rotation of the longitudinal plane should visualize the entire aortic arch, but the proximal aortic arch may not be visualized when the aortic arch is unfolded. The transducer will need to be withdrawn slightly to image the arch vessels, which course superiorly. In one third of patients, all three arch vessels can be imaged, but in the other two thirds of patients, only the two distal arch vessels can be imaged. It is rare not to be able to image at least one arch vessel. As a rule, the brachiocephalic artery, which is anterior and more rightward, is the most difficult to image because of the interposing trachea. The transverse plane in a more superior location may sometimes show the three arch vessels in their short axis. Advancing the probe by 1 to 2 cm so that the imaging plane is just inferior to the aortic arch can frequently image the proximal left pulmonary artery. It is sometimes possible to follow it to the first bifurcation. This view should be sought in the assessment of patients suspected of having pulmonary embolism.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/8.html/top
Doppler Examination Transesophageal echocardiography can be used to assess the flow patterns across the four cardiac valves, but it does not provide additional information to TTE. Furthermore, good alignment with the transvalvular flows may not be feasible because of the anatomic confines of the esophagus. On the other hand, intracardiac flows such as pulmonary vein flow and left atrial appendage flow are best evaluated by TEE and provide important insight into intracardiac hemodynamics. Pulmonary Vein Flow The pulmonary veins are imaged from the midesophagus level. Pulmonary vein flow can be assessed by placing the pulsed Doppler = sample=20 volume 0.5 to 1.0 cm into the pulmonary veins. The anterior to posterior = direction of the left and right upper pulmonary veins allows the Doppler = ultrasound beam to be aligned parallel to blood flow. This often cannot = be=20 achieved when interrogating the left and right lower pulmonary = veins. The normal pulmonary venous flow pattern can be = divided=20 into three phases: (1) antegrade systolic flow, (2) antegrade diastolic = flow,=20 and (3) retrograde atrial contraction flow reversal (F= ig.=20 1-18) . Two phases of antegrade systolic flow can usually be = appreciated on=20 transesophageal study. Systolic flow is dependent on apical displacement = of the=20 annulus, which is predominantly determined by left ventricular function, = atrial=20 relaxation, and atrial compliance.[3= 0]=20 [3= 1]=20 Left atrial pressure also affects antegrade systolic flow, with = increases in=20 left atrial pressure reducing systolic flow.[3= 0]=20 [3= 1]=20 Mitral regurgitation increases left atrial pressure during systole and = may=20 result in systolic flow reversal in one or all pulmonary=20 veins.[3= 0]=20 [3= 1] =20 Diastolic antegrade flow occurs as the mitral valve opens and left = atrial=20 pressure falls. The diastolic flow profile is dependent on left atrial = pressure,=20 left ventricular relaxation, and ventricular compliance. = [3= 0] =20 [3= 1]=20 Atrial contraction flow reversal is dependent on atrial contractility, = atrial=20 systolic pressure, and left ventricular compliance. The normal pulmonary = venous=20 flow pattern is dependent on heart rate and age.[3= 1]=20 [3= 2]=20 Higher systolic pulmonary venous flow velocities, higher atrial reversal = velocities, and smaller diastolic flow velocities=20
Figure = 1-18 Normal pulmonary venous flow showing two antegrade = flows in=20 ventricular systole and diastole, with a diminutive retrograde flow = caused by=20 atrial contraction. .
Book Text
Pagina 2 di 8
patients younger than 50 years of=20 age.[3= 1]=20 [3= 2]=20 Left Atrial Appendage Flow The left atrial appendage can be imaged from = the=20 midesophagus
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 8
aortic valve short-axis view (30 to 60 degrees) or the = midesophagus=20 two-chamber view (80 to 100 degrees). Left atrial appendage flow should = be=20 recorded by positioning the color flow sector over the left atrial = appendage and=20 placing the pulsed-Doppler sample volume at the site of maximal flow = velocity.=20 This usually occurs in the proximal or middle third of the left atrial=20 appendage. Velocity recordings from the distal third of the left atrial=20 appendage frequently incorporate wall motion artefacts and are usually=20 unsatisfactory. Low-velocity flow may be present, and wall filters = should be set=20 low. The pattern of left atrial appendage flow is = dependent on=20 cardiac rhythm.[3= 3]=20 In patients with sinus rhythm, four left atrial appendage flow waves = have been=20 described (F= ig.=20 1-19) : (1) a large positive wave after the electrocardiographic = P-wave,=20 which represents left atrial appendage contraction and emptying; (2) a = large=20 negative early systolic wave immediately following the QRS complex = representing=20 left atrial appendage filling; (3) alternating positive and negative = waves of=20 decreasing velocity throughout the remainder of systole representing = passive=20 flow in and out of the appendage; and (4) a low-velocity positive = emptying wave=20 in early diastole coinciding with rapid left ventricular filling. In = addition, a=20 low-velocity middiastolic negative filling wave representing appendage = filling=20 from the pulmonary veins may follow the early diastolic atrial appendage = emptying wave. The normal velocities are as follows: left atrial = appendage=20 contraction, 60 =B1 14; left atrial appendage filling, 52 =B1 13; and = early=20 diastolic filling, 20 =B1 11 cm per second.[3= 3]=20 [3= 4] =20 In patients with atrial fibrillation, a regular = atrial=20 contraction wave is absent. However, the left atrial appendage continues = to=20 contract, resulting in irregular oscillating positive and negative = emptying and=20 filling waves with variable velocities. The velocities are usually = larger during=20 ventricular diastole when the mitral valve is open, and=20
Figure = 1-19 Normal left atrial appendage flow pattern in sinus = rhythm,=20 showing prominent atrial emptying and filling = velocities.
smaller during systole when the mitral valve is closed. = Of note,=20 mean left atrial appendage velocities tend to be lower with higher heart = rates=20 because of the smaller proportion of time spent during diastole.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 8
The = early=20 diastolic appendage emptying wave, which coincides with early rapid left = ventricular filling, may still be visualized in atrial fibrillation. In = patients=20 with atrial flutter, the velocity waves are more regular and tend to be = of=20 greater velocity because of the slower atrial contraction rate.=20 Factors other than cardiac rhythm that may = affect left=20 atrial appendage velocities have recently been reviewed and include age, = heart=20 rate, left atrial contractility, left atrial pressure, left ventricular = systolic=20 and diastolic function, mitral stenosis, and mitral=20 regurgitation.[3= 3]=20 The potential clinical utility of assessing = left atrial=20 appendage velocities relates to the association of left atrial appendage = velocities with left atrial spontaneous echo contrast and left atrial = appendage=20 thrombus.[3= 3]=20 [3= 5]=20 [3= 6]=20 Atrial fibrillation patients with a left atrial appendage contraction = velocity=20 of less than 20 cm per second are more likely to have left atrial = appendage=20 thrombus and have a greater risk of ischemic stroke compared with = patients with=20 left atrial appendage velocities of 20 cm per second or=20 greater.[3= 5]=20 [3= 6]=20 Lower left atrial appendage velocity has also been observed in stroke = patients=20 with normal sinus rhythm.[3= 7]=20 Other potential utilities may relate to an ability of left atrial = appendage=20 velocities to predict the success of maintaining sinus rhythm following=20 cardioversion of atrial fibrillation.[3= 3]=20 [3= 8]=20 Coronary Artery Flow The assessment of coronary artery flow may be = limited by=20 motion of the heart during the cardiac cycle and difficulties aligning = the=20 Doppler ultrasound beam parallel to coronary blood flow. Coronary artery = blood=20 flow and coronary artery blood flow reserve are best measured in the = distal left=20 main coronary artery or proximal left anterior descending artery using = the=20 midesophagus aortic valve short-axis view, in which the pulsed-Doppler=20 ultrasound beam can be aligned parallel to coronary blood flow. The = ultrasound=20 beam can only rarely be aligned parallel to flow in the left circumflex = artery,=20 and the right coronary artery cannot be imaged in up to half of all = patients.=20 The normal Doppler flow signal is characterized by a large diastolic = component=20 and small systolic component moving away from the transducer. In = general, normal=20 diastolic velocities are 60 cm per second or less, and diastolic = velocities=20 greater 100 cm per second
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 8
suggest significant obstruction in the=20 artery.[3= 9]=20 [4= 0]=20 [4= 1]=20 Additionally, coronary artery flow reserve can be assessed by measuring = peak or=20 mean diastolic coronary flow velocities at rest and then following = dipyridamole=20 or adenosine infusion. [4= 0]=20 [4= 2]=20 Transaortic and Transpulmonary Flow Transaortic flow can be assessed by imaging the = left=20 ventricular outflow tract and aortic valve in the transgastric long-axis = view=20 (100 to 135 degrees) or deep transgastric long-axis view (0 degrees), in = which=20 the probe is=20 12
advanced deep into the stomach = adjacent=20 to the left ventricular apex and anteflexed until the imaging plane is = directed=20 superiorly to the base of the heart. In these views, the pulsed-Doppler = or=20 continuous wave Doppler beam can be aligned parallel to blood flow to = measure=20 transaortic velocity. Stroke volume can be derived with the additional=20 measurement of either the midesophagus left ventricular outflow tract = diameter=20 or the short-axis aortic valve orifice area at valve leaflet=20 level.[4= 3]=20 [4= 4]=20 In patients with aortic stenosis or other forms of left ventricular = outflow=20 tract obstruction, the transvalvular pressure gradients can be derived = using the=20 simplified Bernoulli equation and continuous wave Doppler signals = obtained from=20 the transgastric longaxis or deep transgastric long-axis view.=20 [2= 7]=20 Transpulmonary flow has been measured by = combining either=20 pulsed Doppler or continuous wave Doppler velocity measurements of = pulmonary=20 artery flow obtained from mid-esophagus short- axis images of the main = pulmonary=20 artery and measurements of the main pulmonary artery=20 diameter.[4= 5]=20 [4= 6]=20 Transmitral and Transtricuspid Flow In the midesophageal four-chamber view or = long-axis view,=20 the pulsed Doppler ultrasound beam can be aligned parallel to = transmitral flow=20 to accurately measure transmitral filling velocities. The pulsed Doppler = sample=20 volume should be kept small (3 to 5 mm) and positioned at the mitral = valve=20 leaflet tips for the evaluation of diastolic function and filling=20 pressures.[3= 0]=20 In contrast, transmitral stroke volume is measured by placing the sample = volume=20 at the mitral
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 8
valve annulus, so that velocity and annular dimensions are = measured at the same location.[4= 7]=20 [4= 8]=20 Transtricuspid filling can be assessed by = pulsed Doppler=20 measurements obtained in the midesophageal four-chamber view. However, = it is=20 frequently not possible to align the Doppler ultrasound beam parallel to = blood=20 flow. The transtricuspid filling pattern is similar to the transmitral = filling=20 pattern, although lower velocities are present.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 14
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Indications for Transesophageal Echocardiography The potential utility of TEE in the assessment and management of patients with suspected and overt cardiac disease is wide-ranging and encompasses the spectrum of cardiac problems encountered in clinical cardiology. TEE can be performed on patients in the ambulatory setting, intensive care unit, coronary care unit, or operating room. In general, TTE should be employed as the initial diagnostic investigation, as this technique is noninvasive and will entail no risk to the patient. Patient factors such as obesity, emphysema, or chest deformities frequently limit ultrasound penetration, resulting in nondiagnostic TTE studies. Surgical bandages may limit the number of available acoustic windows, and mechanical ventilation and surgical devices, such as traction and intra-aortic balloon pumps, may limit the ability to properly position the patient. Subcutaneous emphysema may result in the complete TABLE 1-3 -- Common Indications for Transesophageal Echocardiography Nondiagnostic transthoracic echocardiogram Assessment of native valve disease Assessment of prosthetic valves Assessment of infective endocarditis Assessment of a suspected cardioembolic event Assessment of cardiac tumors Assessment of atrial septal abnormalities Assessment of aortic dissection, intramural hematomas, and aortic rupture Evaluation of congenital heart disease Detection of anatomic coronary artery disease Stress echocardiography
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 14
Evaluation of pericardial disease Evaluation of critically ill patients Intraoperative monitoring Monitoring during interventional procedures inability of TTE to visualize cardiac structures. TEE should be considered in these patients to obtain the necessary diagnostic information. Despite an adequate TTE study, TEE may be indicated to assess cardiac structures not usually seen by TTE, such as the superior vena cava, pulmonary veins, and the descending thoracic aorta, or to provide improved anatomic details such as the detection of flail mitral valve leaflet scallops and valvular vegetations, which are not consistently detected by TTE. Finally, TEE has important applications in the operating room, which are discussed in Chapter 2 and Chapter 19 . The common clinical indications for TEE are given in Table 1-3 . Native Valve Disease The presence, etiology, and severity of native valve disease can usually be determined by TTE. TEE should be reserved for the clinical situation in which TTE findings are inconclusive or a more precise characterization of the valve lesion will alter the patient management plan. Excellent visualization of the mitral valve anatomy is possible by TEE because of the close proximity of the mitral valve to the TEE transducer and the ability to image with high-frequency transducers. The mitral annulus, leaflets, chordal structures, and papillary muscles can all be visualized and evaluated. The use of a multiplane transducer allows a comprehensive, detailed examination of the valve to determine the location and mechanism of mitral regurgitation (see Chapter 19) . Ruptured chordae tendineae can be visualized, and precise anatomic localization of prolapsing or flail leaflet scallops is possible to predict the potential for successful mitral valve repair.[25] [49] [50] Abnormalities of the papillary muscles, such as a partial or complete rupture, are better visualized by TEE than TTE.[51] The severity of mitral valve regurgitation can be quantified using the methods employed for TTE,[52] but color Doppler velocity regurgitant jet areas tend to be larger in size on TEE than TTE because higher transducer frequencies are used and because of the close proximity of the transducer to
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 14
the regurgitant jet.[53] Pulmonary vein flow can be assessed in nearly all patients and provides 13
a valuable measure of mitral regurgitation severity.[54] [55] Regurgitant vena contracta width, regurgitant volumes, and regurgitant orifice areas using the proximal flow convergence zone can be obtained by TEE.[56] [57] In mitral stenosis, TTE is usually satisfactory in assessing the valve morphology and severity of stenosis (see Chapter 20) . TEE appears equivalent to TTE in assessing valve mobility and leaflet thickening, but subvalvular disease and calcification may be underestimated owing to the shadowing effect of thickening and calcification of the mitral leaflets and annulus in the esophageal views.[58] Transvalvular pressure gradients can be measured by aligning the continuous wave Doppler beam parallel to left ventricular inflow through the mitral valve in the midesophageal views.[59] Effective orifice areas can be derived by the pressure half-time method,[59] the proximal flow convergence method, or orifice planimetry.[60] Orifice planimetry requires a tomographic cut of the distal or most narrow mitral orifice, however, which is technically more difficult to obtain by TEE and frequently not possible. The potential suitability of a patient for percutaneous balloon mitral valvuloplasty usually incorporates a detailed TEE assessment of the left atrial chamber and appendage to identify thrombus, in addition to an evaluation of the mitral valve morphology score and mitral regurgitation severity.[61] Transthoracic echocardiography can adequately visualize most aortic valve abnormalities, and only rarely is TEE required for assessment. However, subvalvular abnormalities such as subaortic membranes frequently require TEE for definitive diagnosis. [62] The assessment of aortic regurgitation severity only rarely necessitates a TEE evaluation (see Chapter 17) . Standard Doppler methods used for TTE may be employed using TEE.[63] One of the best measures, the ratio of color jet area to left ventricular outflow tract area, can be obtained from esophageal short-axis images of the outflow tract immediately inferior to the aortic valve. Jet height to outflow tract height can be obtained from esophageal long-axis images. Holodiastolic flow reversal in the descending aorta is always present with severe aortic regurgitation and can be detected by biplane or multiplane TEE using pulsed Doppler.[64] Aortic regurgitation severity may also be quantified by TEE using proximal flow convergence methods and vena
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 14
contracta width.[65] [66] The severity of aortic stenosis is best quantified using transvalvular pressure gradients or valve areas derived by TTE (see Chapter 22) . Continuous wave Doppler interrogation of the aortic valve is possible by TEE using the transgastric long-axis view (100 to 135 degrees) or deep transgastric long-axis view (0 degrees) in which the probe is advanced deep into the stomach adjacent to the left ventricular apex and anteflexed until the imaging plane is directed superiorly to the base of the heart (see Fig. 113) . Good correlations between TTE and TEE gradients have been reported, despite the limited TEE windows.[27] Anatomic orifice area can be derived by planimetry of the maximum systolic aortic valve orifice visualized from esophageal short-axis images. Proper transducer position should be confirmed by rotating to the longitudinal plane and verifying that the leaflet tips are being imaged. Aortic valve areas derived by orifice planimetry correlate well with valve areas derived by TTE using the continuity equation and Gorlin equation valve areas.[27] , [67] [68] Valve calcification may affect the accuracy of TEEmeasured orifice areas.[69] Importantly, orifice planimetry is often more feasible and accurate using multiplane than biplane TEE.[68] Prosthetic Valves Transesophageal echocardiography is an extremely valuable technique in the assessment of prosthetic valve function, because TTE visualization of the prosthetic valve components and function is often limited by the echogenicity of the prosthetic components (see Chapter 24 and Chapter 25) . Reverberation artifacts, attenuation artifact, and acoustic shadowing obscure visualization of the prosthetic components and limit the visualization of structures beyond the prosthesis. Thickening and calcification of the leaflets, or the presence of a torn or flail bioprosthetic leaflet, are better appreciated on TEE. The structure and motion of the occluding device of a mechanical prosthesis may also be better evaluated. TEE provides increased sensitivity for detecting abnormalities of bioprosthetic and mechanical prostheses when compared to TTE.[70] [71] Small abnormalities of prosthetic valves such as leaflet thickening, flail leaflets, vegetations, thrombi, and filamentous strands can be missed on TTE but appreciated on TEE.[70] [71] [72] [73] [74] [75] [76] [77] TEE can be used to distinguish pannus from thrombus formation[78] and to guide thrombolytic therapy use in patients with the latter condition.[79] TEE is especially valuable in assessing mitral prostheses, as the transducer's posterior
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 14
position provides excellent visualization of vegetations and thrombi, which usually locate on the left atrial aspect of the prosthesis.[70] [73] However, the ventricular aspect of a mitral prosthesis may not be adequately seen, and so TTE should complement the TEE assessment. [80] Transesophageal echocardiography can differentiate between normal variant and pathologic prosthetic valve regurgitation.[71] [72] [73] [74] [75] [81] Prosthetic mitral regurgitation is frequently better evaluated by TEE than TTE,[71] [72] [74] because TEE provides excellent visualization of the left atrial cavity without any intervening prosthetic material. TEE should be performed in patients in whom significant mitral regurgitation is not seen on TTE but is a clinical concern. Importantly, TEE allows characterization of mitral regurgitation jets as paravalvular or transvalvular in origin, which may modify the surgical procedure.[72] [74] [82] Multiplane TEE appears to better delineate paraprosthetic mitral regurgitation as compared with biplane TEE.[82] The incremental benefit of TEE in the assessment of regurgitation severity is less clear for aortic prostheses because the aortic regurgitation jet is usually well seen on TTE, and TEE visualization of prosthetic aortic regurgitation may be compromised by partial obstruction of the aortic regurgitation jet by either a mitral or aortic prosthesis in the esophageal views.[75] All bioprostheses and mechanical prostheses are inherently stenotic. The degree of stenosis is dependent on the prosthesis type and size and the presence of an associated pathologic condition such as leaflet calcification, pannus formation, or valve thrombosis.[83] In general, TTE is sufficient to assess the severity of prosthetic aortic or mitral 14
stenosis, but only TEE has sufficient resolution to distinguish these pathologic conditions.[78] In patients with inadequate TTE findings, TEE can quantify prosthetic mitral stenosis by measuring diastolic pressure gradients, pressure half-time, and effective orifice area using the proximal flow convergence method, as described for native mitral stenosis.[60] [84] Prosthetic aortic stenosis can be assessed by measuring transvalvular pressure gradients, as described for native aortic stenosis. [27] Importantly, flow through certain mechanical aortic prostheses results in localized pressure gradients and significant pressure recovery, which may lead to a discrepancy between Doppler and catheterization pressure gradients and an apparent "overestimation" of Doppler gradients.[85]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 14
Infective Endocarditis The presence of a vegetation is a hallmark finding of infective endocarditis, and its identification in the clinical setting of suspected endocarditis confirms the diagnosis[86] (see Chapter 21) In native valve endocarditis, the sensitivity of TTE for the detection of vegetations was 28% to 63%, and the sensitivity of TEE was 86% to 98%. [87] [88] [89] [90] [91] The specificity of the TTE and TEE findings for a vegetation appears similar and exceeds 90% when strict echocardiographic criteria are used for diagnosis.[87] [88] [90] Smaller vegetations are more likely to be detected by TEE than TTE.[88] Isolated case reports have suggested that pulmonic valve vegetations may also be better seen by TEE.[92] TEE does not appear to have an increased sensitivity compared with TTE, however, in the detection of tricuspid valve vegetations.[93] Prosthetic valve endocarditis is more difficult to diagnose using either TTE or TEE. The reported sensitivity of TTE for detecting vegetations was 0 to 43%, and the sensitivity of TEE was superior at 33% to 86%.[70] [89] [94] , [95] Thus, TEE should be performed in patients with suspected prosthetic valve endocarditis if the TTE procedure does not identify a vegetation. Although TEE has an improved sensitivity for detecting vegetations compared with TTE, the impact of TEE on diagnosis appears to be greatest in patients with suspected endocarditis with an intermediate clinical probability of endocarditis, especially patients with prosthetic valves.[96] Importantly, the absence of a vegetation on TEE makes the diagnosis of endocarditis unlikely (<10%), and alternative diagnoses should be considered.[95] [97] However, false-negative TEE studies have been reported, and patients with a high index of suspicion of endocarditis, prosthetic valves, or a persistent bacteremia may benefit from follow-up TEE if the initial study was negative.[95] [97] The complications of infective endocarditis, including abscess formation, leaflet diverticula, leaflet perforation, fistula tracts, mycotic aneurysms, and pseudoaneurysm formation, are better detected by TEE than TTE.[89] [98] [99] [100] [101] In a large series of patients with infective endocarditis, only 28% of surgically or autopsy confirmed abscess cavities were identified by TTE, as opposed to an 87% detection rate by TEE.[98] The specificity of both techniques in the detection of abscess formation exceeded 90%. Thus, patients with a suspected abscess based on clinical grounds or persistent bacteremia should undergo TEE.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 14
The role or potential utility of TEE in uncomplicated confirmed endocarditis is controversial. TEE may provide the clinician with prognostic information. Larger, mobile vegetations on TEE are associated with systemic embolization.[91] Additionally, complications including embolism, abscess formation, need for valve replacement, and death may be more likely to occur in patients with a vegetation that fails to decrease in size with therapy.[102] At this time, we do not perform routine follow-up TEE for cases of uncomplicated confirmed endocarditis. Suspected Cardioembolic Event The potential for a cardioembolic event should be considered in patients suffering cerebral ischemia or a peripheral arterial embolus. The Cerebral Embolism Task Force has suggested that cardiac emboli account for 15% of cerebral ischemic events.[103] Several cardiac abnormalities have a strong association with cardioembolic events and are considered a major risk source (see Chapter 37) . These abnormalities include atrial fibrillation, left atrial or left ventricular thrombi, vegetations, intracardiac tumor, mitral stenosis, mechanical valves, recent myocardial infarction, dilated cardiomyopathy, and intra-aortic debris.[104] Minor risk sources with weaker associations include cardiac abnormalities such as atrial septal aneurysms, patent foramen ovale, spontaneous echo contrast, mitral annular calcification, and mitral valve prolapse.[104] Many of these conditions can be diagnosed by clinical assessment, but echocardiography is frequently required for the diagnosis of many of the anatomic abnormalities. Approximately 7% of patients with a suspected cardioembolic event will have left atrial thrombus in the absence of atrial fibrillation and mitral stenosis. [105] The thrombus is frequently located in the left atrial appendage, a region poorly visualized on TTE. The sensitivity of TTE in detecting left atrial thrombus has been reported to be only 0 to 53%, whereas TEE has a sensitivity of 93% to 100% and a specificity exceeding 95%.[106] [107] In contrast, left ventricular thrombi may be better appreciated by TTE than TEE because of the close proximity of the left ventricular apex to the TTE transducer and the far field position and frequent apical foreshortening of the left ventricular apex on TEE.[108] However, TEE assessment may be beneficial if the TTE findings are inconclusive. [109] Left atrial spontaneous echo contrast is rarely appreciated on TTE, but well seen on TEE because of the close proximity of the left atrium to the TEE transducer and use of higher frequency transducers.[110] TEE may better detect small myxomas and aid in the diagnosis and management by better characterizing the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 14
attachment site.[111] [112] Similarly, TEE is superior in the detection of patent foramen ovale and atrial septal aneurysms.[113] [114] The size of the patent foramen ovale is associated with the cardioembolic risk and can better be appreciated by TEE.[115] A comprehensive characterization of aortic arch atheroma is rarely possible by TTE alone and requires TEE assessment.[35] [116] [117]
The indication for performing a TEE in patients with a suspected cardioembolic event is controversial. Although TEE has a better sensitivity than TTE for detecting potential 15
cardioembolic abnormalities, the yield for identifying a major risk source is limited. An analysis of pooled data from more than 30 cross-sectional studies suggested an overall detection rate for intracardiac masses of 4% for TTE and 11% for TEE.[104] However, the yield was greater in patients with evidence of cardiac disease. TTE and TEE identified an intracardiac mass in 13% and 19% of patients with cardiac disease and only 0.7% and 1.6% in patients without cardiac disease, respectively. In addition, the information obtained by TEE, which may include the identification of minor risk sources, may not significantly alter patient management.[104] [118] Many management decisions will be predetermined by the clinical setting (e.g., the patient with atrial fibrillation requires anticoagulation), and the management of patients with minor-risk cardiac abnormalities is frequently controversial. Thus, TEE should only be performed if the results have a reasonable chance of altering patient management or therapy. In this regard, TEE may have the greatest impact on patient management in the clinical setting of patients younger than 55 years of age with unexplained cerebral ischemia, in patients having recurrent events, or in patients with suspected endocarditis. Atrial Septal Abnormalities Transesophageal echocardiography provides excellent visualization of the atrial septum because of the atrial septum's close proximity to the transducer and perpendicular orientation to the ultrasound beam. Abnormalities of the atrial septum, including atrial septal defects, atrial septal aneurysms, and patent foramen ovale, are identified more frequently by TEE than by TTE.[19] [113] [114] , [119] [120] Sinus venosus defects and associated anomalous pulmonary venous drainage are frequently not
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 14
identified on transthoracic imaging but can be easily detected on TEE study. [19] [20] TEE can be used to assess the severity of left-to-right shunting across the defect, determine the potential for percutaneous closure by accurate localization and characterization of the defect, and be used to assist in proper device placement during percutaneous closure.[121] [122] TEE can also detect thrombus formation within an atrial septal aneurysm and paradoxic emboli across an atrial septal defect.[115] [120] Cardiac Tumors For detecting intracardiac tumors, TEE appears superior to TTE, computed tomography, angiography, and magnetic resonance imaging.[112] [123] The sensitivity of TTE and TEE for the detection of atrial myxomas has been reported to be 95% and 100%, respectively.[123] Nonmyxomatous intracardiac tumors are identified by TTE and TEE in 91% and 100% of patients, respectively.[123] Pericardial or paracardial tumors are detected in only 67% by TTE and 97% by TEE.[123] TEE appears especially valuable in the detection of tumors located at the base of the heart, adjacent to the great vessels, or adjacent to the right heart.[112] [123] In addition, TEE is superior to TTE in characterizing features of a cardiac tumor that may assist in the diagnosis and management, such as the involvement of multiple chambers, the site of tumor attachment, the presence of multiple tumors, infiltration of adjacent structures, tumor calcification, or cyst formation.[112] [123] TEE has been used to guide percutaneous biopsy of intracardiac tumors.[124] However, the size and extent of paracardial involvement is not well assessed by TTE or TEE. In this setting, tomographic imaging with a wider field of view (magnetic resonance imaging or computed tomography) is needed. Aortic Dissection, Intramural Hematoma, and Rupture Aortic dissection can be detected by TEE with a high degree of accuracy and is the diagnostic investigation of choice for suspected aortic dissection in many institutions (see Chapter 3) . [125] The ascending aorta, aortic arch, and descending thoracic aorta can be visualized with excellent resolution owing to the close proximity of the aorta to the transducer and the use of high-frequency transducers. Importantly, a small segment of the superior ascending aorta cannot be visualized using TEE owing to the interposition of the air-filled trachea and bronchus. The sensitivity of monoplane and biplane TEE for the diagnosis of aortic dissection has been reported to be 97% to 100%, with a specificity that has ranged from 77% to 100%.[125] [126] [127] [128] The specificity was found to be greater than 95%, except in one
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 14
study.[126] Multiplane TEE has been associated with similar sensitivities and specificities of 98% to 100% and 94% to 95%, respectively.[129] [130] The sensitivity and specificity of TEE compares favorably with those of other technologies, including aortography, computed tomography, and magnetic resonance imaging.[126] [127] [128] In addition to diagnosis, TEE can determine the extent of the dissection, differentiate the true and false lumens, identify thrombus within the false lumen, identify the site of the intimal tear, and assess for aortic valve involvement. [125] , [126] Involvement of the arch vessels and coronary arteries can also be determined.[125] Additionally, TEE can detect findings of aortic rupture, such as a pericardial effusion, pleural effusion, or mediastinal hematoma, which may significantly alter surgical therapy.[125] Aortic complications after repair may also be detected.[131] Associated aortic abnormalities, such as intramural hematoma and penetrating aortic ulcers, may have a similar presentation to aortic dissection and can be diagnosed using TEE.[128] [129] [132] TEE appears to have a high sensitivity and specificity for the detection of intramural hematoma, [129] but the diagnostic accuracy in the detection of penetrating aortic ulcers is unclear. In the largest series of 12 patients, penetrating aortic ulcers were identified by TEE in 83% of patients.[132] Transesophageal echocardiography has been used in the setting of chest trauma for the diagnosis of traumatic aortic rupture. The reported sensitivity and specificity for the detection of traumatic aortic rupture has ranged from 63% to 100% and 84% to 100%, respectively.[117] [133] However, TEE cannot consistently visualize the superior ascending aorta and aortic arch branch vessels, a frequent site of traumatic injury.[134] Thus, the role of TEE in the diagnostic evaluation of chest trauma patients remains undefined. Congenital Heart Disease
16
Transesophageal echocardiography commonly adds information to the preoperative, intraoperative, and postoperative assessment and management of patients with congenital heart disease[135] [136] (see Chapter 39 , Chapter 40 , Chapter 41 ). TEE can better appreciate abnormalities of the atrial septum and pulmonary veins, and it can be used to guide percutaneous
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 14
closure of atrial septal defects.[19] [20] [119] , [121] [122] [124] In patients with atrioventricular canal defects, the atrioventricular valves and site of chordal insertion can be visualized to determine the potential for surgical valvuloplasty. [137] TEE provides good visualization of an atrial baffle and can detect stenoses or leaks.[138] Complications of a Fontan procedure, such as obstruction or thrombosis, can be evaluated.[139] TEE can characterize right and left ventricular outflow tract obstructions.[62] [135] [137] Abnormalities of the aorta, including aortic coarctation and patent ductus arteriosus, are also better appreciated by TEE than by TTE.[140] [141] Coronary Artery Disease Transesophageal echocardiography can be employed for the diagnosis of coronary artery disease by (1) visualization of coronary stenoses in the proximal vessels or (2) detection of stress-induced regional wall motion abnormalities. The left main coronary artery can be visualized in more than 85% of patients.[39] [142] [143] [144] [145] The proximal left anterior descending artery and proximal left circumflex artery can also be visualized in most patients.[142] [143] [144] The proximal right coronary artery is more difficult to visualize but may still be seen in 50% of patients or more.[142] [144] Several studies have examined the accuracy of TEE in identifying coronary stenoses in the proximal segments of the coronary arteries using two-dimensional and color flow imaging. In patients with visualized vessels, the sensitivity of TEE in identifying significant left main coronary stenoses has been reported to be 91% to 100%, with specificities greater than 90%.[39] [142] [143] [144] [145] The sensitivity for detecting significant proximal left anterior descending artery disease, left circumflex artery disease, and right coronary artery disease has been reported to be 78% to 100%, 50% to 89%, and 82% to 100%, respectively.[142] [143] [144] The sensitivity for detecting coronary artery stenoses significantly decreases, however, if patients with nonvisualized segments are included in the analysis.[144] One author has reported employing TEE and the continuity equation to quantify the severity of stenoses in the left anterior descending artery.[41] In addition, coronary artery flow reserve can be measured using TEE, and differences in flow reserve can be detected in patients with left anterior descending artery stenoses.[40] [42] TEE should not replace coronary angiography in the diagnosis of proximal coronary artery stenoses, but it may be useful in assessing angiographically questionable stenoses involving the left main ostium or the left anterior descending artery in centers in which
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 14
intravascular ultrasonography is not available.[146] Stress echocardiography with TEE imaging has been used to evaluate patients with suspected or confirmed coronary artery disease.[147] [148] TEE provides high-quality images with excellent endocardial resolution. Stress techniques employed to induce ischemia have included transesophageal atrial pacing and pharmacologic methods using either dobutamine or dipyridamole.[147] [148] These techniques have been shown to be highly accurate in the detection of coronary artery disease and to provide information useful in risk stratification, and they may be useful in the assessment of myocardial viability in patients with left ventricular dysfunction.[147] [148] TEE is an invasive procedure with potential risks, however, and stress echocardiography with TEE imaging should be reserved for patients who have poor TTE images. Additional applications of TEE in the assessment of coronary artery disease include the detection of anomalous coronary arteries and the detection and mapping of coronary artery fistulas.[149] Pericardial Disease Pericardial effusions and cardiac tamponade are usually easily diagnosed on TTE and do not require TEE (see Chapter 29) . However, the detection of cardiac tamponade after cardiac surgery can be difficult to diagnose by TTE. Local compression of the right atrium by extracardiac thrombus may not be apparent on TTE because of the posterior position of the thrombus and poor TTE images related to suboptimal patient position, surgical bandages, and drainage tubes. TEE circumvents these problems and can better detect extracardiac compression.[150] Constrictive pericarditis and restrictive physiologic diseases can usually be differentiated on TTE using respiratory monitoring. In patients with nondiagnostic TTE, however, TEE with respiratory monitoring may be useful in differentiating these diseases. [151] Pericardial thickening can be measured by TEE and correlates with computed tomography. [152] In one study, TEE was shown to be superior to TTE in assessing pericardial thickening, intrapericardial metastases, intrapericardial thrombus, and pericardial cysts.[150] Intensive Care Unit The TTE images obtained in the intensive care unit are frequently inadequate because of poor acoustic penetration, limited windows from surgical bandages and drains, mechanical ventilation, and an inability to
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 14
properly position patients. In this setting, TEE can provide essential information that alters patient management. TEE has been shown to be valuable in the assessment of the patient with unexplained hypotension, pulmonary edema, and hypoxia.[153] [154] TEE provides information on myocardial function, valve function, and volume status, which is critical in evaluating the patient with unexplained hypotension or unexplained pulmonary edema. TEE can detect right-to-left intracardiac shunting through a patent foramen ovale, which may occur in ventilated patients requiring high levels of pressure support and right ventricular infarction. [155] [156] The presence of massive or proximal pulmonary emboli can be diagnosed by TEE.[22] [23] Potential complications of myocardial infarction, including left ventricular 17
dysfunction, papillary muscle rupture, and myocardial rupture, may be detected. Intraoperative Monitoring Intraoperative TEE can provide detailed information on cardiac anatomy and function not obtainable by other monitoring technologies and can obtain this information without disrupting the surgical procedure.[157] [158] TEE can evaluate global and segmental left ventricular function, detect intraoperative myocardial ischemia, and monitor hemodynamics, including cardiac output, left ventricular filling pressures, and volume status. The cause of hemodynamic disturbances can be determined and intraoperative complications identified. Importantly, the adequacy of valve repairs or replacements and surgical reconstructions for congenital and acquired diseases can be evaluated prior to leaving the operating room. In 1996, the American Society of Anesthesiologists published recommendations for performing TEE based on the strength of supporting evidence and expert opinion that TEE improved clinical outcome.[157] The complete list of potential indications for TEE in the intraoperative period is extensive and is discussed in more detail in Chapter 2 and Chapter 19 . Monitoring During Interventional Procedures Transesophageal echocardiography is a valuable adjunct to percutaneous mitral valvuloplasty. TEE can guide catheter placement during trans-septal puncture, assist in proper balloon placement, evaluate the valvuloplasty result, identify complications, and shorten procedure and fluoroscopy
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 14
times.[121] [159] It has been used to assist in right ventricular biopsies and biopsies of intracardiac masses.[124] [160] TEE may assist in trans-septal puncture and proper catheter position for radiofrequency ablation.[161] TEE has been used to guide catheter position for percutaneous closure of atrial septal defects, patent ductus arteriosus, ventricular septal defects, and coronary artery fistulas.[122] [162] [163] [164] TEE has also been found to be useful in the pediatric population during creation or enlargement of an interatrial communication or balloon dilation of obstructive left heart lesions. [165] Electrical cardioversion of atrial fibrillation without prolonged anticoagulation has been proposed as a safe procedure if TEE excludes left atrial thrombus.[166] However, this management scheme is controversial and requires further investigation (see Chapter 38) .[167]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/10.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Contraindications to Transesophageal Echocardiography Patients undergoing TEE should be kept on NPO (nothing by mouth) status for 4 to 6 hours prior to the procedure because of the potential for vomiting and aspiration. However, urgent procedures can likely be performed earlier with minimal risk of vomiting and aspiration if there has been only clear fluid intake up to 2 hours prior to the procedure.[168] TEE should not be performed in the uncooperative patient. Patients who are uncooperative should either have the study deferred or be sedated and paralyzed, if necessary. Patients with a tenuous cardiorespiratory status should be intubated and ventilated to avoid decompensation during the procedure. To avoid esophageal rupture, TEE should not be attempted in a patient with esophageal obstruction caused by a stricture or mass. The presence of an esophageal diverticulum should also be considered a relative contraindication because of the possibility of the probe entering and perforating the diverticulum. TEE is contraindicated in the patient with a perforated viscus or active gastrointestinal bleed. Esophageal varices are not a contraindication to TEE. However, the potential additive information should be weighed against the small risk of major bleeding. Severe cervical arthritis or dislocation of the atlantoaxial joint, in which flexion of the neck is severely limited or impossible, should be considered a relative contraindication to TEE. TEE can be performed safely in patients receiving anticoagulation therapy.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/11.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 3
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Complications of Transesophageal Echocardiography Transesophageal echocardiography is a relatively safe procedure with a low complication rate. Procedural complications have been observed in 0.47% to 2.80% of patients with successful esophageal intubation, however (Table 1-4) .[5] [9] [11] [169] The vast majority of complications are minor. Major complications, defined in one study as death, laryngospasm, sustained ventricular tachycardia, or congestive heart failure, occur in approximately 0.3% of patients.[169] In the Multicenter European Survey of 10,419 examinations, the TEE examination had to be interrupted prior to completion in 0.88% of studies.[11] Patient TABLE 1-4 -- Procedural Complications with Transesophageal Echocardiography Major Complications Death Esophageal rupture Laryngospasm or bronchospasm Congestive heart failure or pulmonary edema Sustained ventricular tachycardia Minor Complications Excessive retching or vomiting Sore throat Hoarseness Minor pharyngeal bleeding Blood-tinged sputum Nonsustained or sustained supraventricular tachycardia Atrial fibrillation
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 3
Nonsustained ventricular tachycardia Bradycardia or heart block Transient hypotension Transient hypertension Angina Transient hypoxia Parotid swelling Tracheal intubation
18
intolerance of the probe, including excessive retching or vomiting, was the most common complication, resulting in premature termination of the procedure.[11] In the largest series, deaths have been reported in 0 to 0.03% of patients.[5] [9] [11] , [169] Cardiac complications reported include nonsustained and sustained supraventricular tachycardias or atrial fibrillation, nonsustained and sustained ventricular tachycardia, bradycardia, transient hypotension or hypertension, angina pectoris, congestive heart failure, and pulmonary edema. Pulmonary complications have included transient hypoxia and laryngospasm. Bleeding complications have included minor pharyngeal bleeding or blood-tinged sputum, MalloryWeiss tear, and severe hematemesis in a patient with a malignant tumor invading the esophagus. A minor sore throat may be present for 24 hours after the procedure. Adverse reactions may occur as a result of intravenous sedation, topical anesthesia, or drying agents such glycopyrrolate. Intravenous sedation may result in respiratory depression and hypoxia, hypotension, or paradoxical reactions. Topical anesthesia with benzocaine or lidocaine may result in acute toxic methemoglobinemia, a rare condition in which hemoglobin is oxidized by the topical anesthesia agent and is unable to carry oxygen to the tissues.[170] The partial pressure of oxygen in the blood is normal, but oxyhemoglobin levels are decreased. Patients usually develop cyanosis and dyspnea. On pulse oximetry, oxygen saturation often appears only mildly reduced because this technique cannot distinguish methemoglobin and reduced hemoglobin. The diagnosis can be confirmed with an arterial blood gas sample with measurement of methemoglobinemia. Methylene blue (1
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Summary Transesophageal echocardiography is a very powerful tool that provides a unique acoustic window to assess cardiac structure and function. In our view, a comprehensive study should include the standard views discussed in this chapter. When dealing with specific clinical problems, additional views should be used to obtain the necessary diagnostic information. In critically ill patients, we believe that the initial views should be those that are most pertinent to the clinical question. Adequate diagnostic information would then have been obtained even if the study needs to be terminated prematurely. Finally, we need to be mindful that TEE is a semi-invasive procedure and is not free of risks. Clear and convincing indications should be present before a TEE study is performed.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/13.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 16
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
References 1. Frazin L, Talano JV, Stephanides L, et al: Esophageal echocardiography.
Circulation 1976;54:102–108. 2. Pearlman AS, Gardin JM, Martin RP, et al: Guidelines for physician training in
transesophageal echocardiography: Recommendations of the American Society of Echocardiography Committee for physician training in echocardiography. J Am Soc Echocardiogr 1992;5:187–194. 3. Chan K, Burwash I: Unusual structural abnormality in a biplane transesophageal
transducer with normal imaging function. Am Soc Echocardiog 1998;11:310–312. 4. Kronzon I, Cziner DG, Katz ES, et al: Buckling of the tip of the transesophageal
echocardiography probe: A potentially dangerous technical malfunction. J Am Soc Echocardiogr 1992;5:176–177. 5. Chan KL, Cohen GI, Sochowski RA, et al: Complications of transesophageal
echocardiography in ambulatory adult patients: Analysis of 1500 consecutive examinations. J Am Soc Echocardiogr 1991;4:577–582. 6. Chan K: Impact of transesophageal echocardiography on the management of
patients with aortic dissection. Chest 1991;101:406–410. 7. Steckelberg JM, Khandheria BK, Anhalt JP, et al: Prospective evaluation of the risk
of bacteremia associated with transesophageal echocardiography. Circulation 1991;84:177–180. 8. Melendez L, Chan K, Cheung P, et al: Incidence of bacteremia in transesophageal
echocardiography: A prospective study of 140 consecutive patients. J Am Coll Cardiol 1991;18:1650–1654. 9. Tam JW, Burwash IG, Ascah KJ, et al: Feasibility and complications of single-plane
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 16
and biplane versus multiplane transesophageal imaging: A review of 2947 consecutive studies. Can J Cardiol 1997;13:81–84. 10. Yvorchuk K, Sochowski R, Chan K: A prospective comparison of the multiplane
probe with the biplane probe in structure visualization and Doppler examination during transesophageal echocardiography. J Am Soc Echocardiog 1995;8:111–120. 11. Daniel WG, Erbel R, Kasper W, et al: Safety by transesophageal
echocardiography: A multicenter survey of 10,419 examinations. Circulation 1991;83:817–821. 12. Cohen G, Chan K: Biplane transesophageal echocardiography: Clinical
applications of the long-axis plane. J Am Soc Echocardiogr 1991;4:155–163. 13. Seward JB, Khandheria BK, Freeman WK, et al: Multiplane transesophageal
echocardiography: Image orientation, examination technique, anatomic correlations, and clinical applications. Mayo Clin Proc 1993;68:523–551. 14. Marx GR, Fulton DR, Pandian NG, et al: Delineation of site, relative size and
dynamic geometry of atrial septal defects by real-time three dimensional echocardiography. J Am Coll Cardiol 1995;25:482–490. 15. Flachskampf FA, Chandra S, Gaddipatti A, et al: Analysis of shape and motion of
the mitral annulus in subjects with and without cardiomyopathy by echocardiographic 3-dimensional reconstruction. J Am Soc Echocardiogr 2000;13:277–287. 16. Seward JB, Khandheria BK, Oh JK, et al: Transesophageal echocardiography:
technique, anatomic correlations, implementation, and clinical applications. Mayo Clin Proc 1988;63:649–680. 17. Anderson R, Dussek J, Evans S, et al: Cardiovascular. In Williams PL (ed): Gray's
Anatomy, 38th ed. New York, Churchill Livingstone, 1995, pp 1482–1483. 18. Veinot JP, Harrity PJ, Gentile F, et al: Anatomy of the normal left atrial
appendage: A quantitative study of age-related changes in 500 autopsy hearts— implications for echocardiographic examination. Circulation 1997;96:3112–3115. 19. Kronzon I, Tunick PA, Freedberg RS, et al: Transesophageal echocardiography is
superior to transthoracic echocardiography in the diagnosis of sinus venosus atrial septal defect. J Am Coll Cardiol 1991;17:537–542. 20. Pascoe RD, Oh JK, Warnes CA, et al: Diagnosis of sinus venosus atrial septal
defect with transesophageal echocardiography. Circulation 1996;94:1049–1055.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 16
21. Fagan S, Veinot JP, Chan KL: Residual sinus venosus atrial septal defect following
surgical closure of atrial septal defect. J Am Soc Echocardiogr 2001 (in press). 22. Wittlich N, Erbel R, Eichler A, et al: Detection of central pulmonary artery
thromboemboli by transesophageal echocardiography in patients with severe pulmonary embolism. J Am Soc Echocardiogr 1992;5:515–524. 23. Pruszczyk P, Torbicki A, Pacho R, et al: Noninvasive diagnosis of suspected
severe pulmonary embolism: transesophageal echocardiography vs spiral CT. Chest 1997;112:722–728. 19
24. Shanewise JS, Cheung AT, Aronson S, et al: ASE/SCA guidelines for performing a
comprehensive intraoperative multiplane transesophageal echocardiography examination: Recommendations of the American Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. J Am Soc Echocardiogr 1999;12:884–900. 25. Enriquez-Sarano M, Freeman WK, Tribouilloy CM, et al: Functional anatomy of
mitral regurgitation: Accuracy and outcome implications of transesophageal echocardiography. J Am Coll Cardiol 1999;34:1129–1136. 26. Pieper EP, Hellemans IM, Hamer HP, et al: Additional value of biplane
transesophageal echocardiography in assessing the genesis of mitral regurgitation and the feasibility of valve repair. Am J Cardiol 195;75:489–493. 27. Blumberg FC, Pfeifer M, Holmer SR, et al: Transgastric Doppler
echocardiographic assessment of the severity of aortic stenosis using multiplane transesophageal echocardiography. Am J Cardiol 1997;79:1273–1275. 28. Catoire P, Beydon L, Delaunay L, et al: Persistent left superior vena cava
diagnosed by transesophageal echocardiography. J Cardiothorac Vasc Anesth 1993;7:375–379. 29. Seward JB, Khandheria BK, Edwards WD, et al: Biplanar transesophageal
echocardiography: Anatomic correlations, image orientation, and clinical applications. Mayo Clin Proc 1990;65:1193–1213.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 16
30. Nishimura RA, Tajik AJ: Evaluation of diastolic filling of left ventricle in health
and disease: Doppler echocardiography is the clinician's Rosetta stone. J Am Coll Cardiol 1997;30:8–18. 31. Klein AL, Tajik AJ: Doppler assessment of pulmonary venous flow in healthy
subjects and in patients with heart disease. J Am Soc Echocardiogr 1991;4:379–392. 32. Klein AL, Burstow DJ, Tajik AJ, et al: Effects of age on left ventricular
dimensions and filling dynamics in 117 normal persons. Mayo Clin Proc 1994;69:212–224. 33. Agmon Y, Khandheria BK, Gentile F, et al: Echocardiographic assessment of the
left atrial appendage. J Am Coll Cardiol 1999;34:1867–1877. 34. Tabata T, Oki T, Fukuda N, et al: Influence of aging on left atrial appendage flow
velocity patterns in normal subjects. J Am Soc Echocardiogr 1996;9:274–280. 35. The Stroke Prevention in Atrial Fibrillation Investigators Committee on Echocardiography: Transesophageal echocardiographic correlates of thromboembolism in high-risk patients with nonvalvular atrial fibrillation. Ann Intern Med 1998;128:639–647. 36. Goldman ME, Pearce LA, Hart RG, et al: Pathophysiologic correlates of
thromboembolism in nonvalvular atrial fibrillation: I. Reduced flow velocity in the left atrial appendage (The Stroke Prevention in Atrial Fibrillation [SPAFF-III] study). J Am Soc Echocardiogr 1999;12:1080–1087. 37. Kamalesh M, Copeland TB, Sawada S: Severely reduced left atrial appendage function: A cause of embolic stroke in patients in sinus rhythm? J Am Soc Echocardiogr 1998;11:902–904. 38. Verhorst PM, Kamp O, Welling RC, et al: Transesophageal echocardiographic
predictors for maintenance of sinus rhythm after electrical cardioversion of atrial fibrillation. Am J Cardiol 1997;79:1355–1359. 39. Yamagishi M, Yasu T, Ohara K, et al: Detection of coronary blood flow associated
with left main coronary artery stenosis by transesophageal Doppler color flow echocardiography. J Am Coll Cardiol 1991;17:87–93. 40. Kozakova M, Palombo C, Pratali L, et al: Assessment of coronary reserve by
transoesophageal Doppler echocardiography: Direct comparison between different modalities of dipyridamole and adenosine administration. Eur Heart J 1997;18:514– 523.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 16
41. Isaaz K, da Costa A, de Pasquale JP, et al: Use of the continuity equation for
transesophageal Doppler assessment of severity of proximal left coronary artery stenosis: A quantitative coronary angiography validation study. J Am Coll Cardiol 1998;32:42–48. 42. Redberg RF, Sobol Y, Chou TM, et al: Adenosine-induced coronary vasodilation during transesophageal Doppler echocardiography: Rapid and safe measurement of coronary flow reserve ratio can predict significant left anterior descending coronary stenosis. Circulation 1995;92:190–196. 43. Feinberg MS, Hopkins WE, Davila-Roman VG, et al: Multiplane transesophageal
echocardiographic Doppler imaging accurately determines cardiac output measurement in critically ill patients. Chest 1995;107:679–673. 44. Katz WE, Gasior TA, Quinlan JJ, et al: Transgastric continuous-wave Doppler to
determine cardiac output. Am J Cardiol 1993;71:853–857. 45. Gorscan J III, Diana P, Ball BA, et al: Intraoperative determination of cardiac
output by transesophageal continuous wave Doppler. Am Heart J 1992;123:171–176. 46. Muhiudeen IA, Kuecherer HF, Lee E, et al: Intraoperative estimation of cardiac
output by transesophageal pulsed Doppler echocardiography. Anesthesiology 1991;74:9–14. 47. Hozumi T, Shakudo M, Applegate R, et al: Accuracy of cardiac output estimation
with biplane transesophageal echocardiography. J Am Soc Echocardiogr 1993;6:62– 68. 48. Pu M, Griffin BP, Vandervoort PM, et al: Intraoperative validation of mitral inflow
determination by transesophageal echocardiography: Comparison of single-plane, biplane and thermodilution techniques. J Am Coll Cardiol 1995;26:1047–1053. 49. Foster GP, Iselbacher EM, Rose GA, et al: Accurate localization of mitral
regurgitation defects using multiplane transesophageal echocardiography. Ann Thorac Surg 1998;65:1025–1031. 50. Grewal KS, Malkowski MJ, Kramer CM, et al: Multiplane transesophageal
echocardiographic identification of the involved scallop in patients with flail mitral valve leaflet: Intraoperative correlation. J Am Soc Echocardiogr 1998;11:966–971. 51. Moursi MH, Bhatnagar SK, Vilacosta I, et al: Transesophageal echocardiographic
assessment of papillary muscle rupture. Circulation 1996;94:1003–1009. 52. Schiller NB, Foster E, Redberg RF: Transesophageal echocardiography in the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 16
evaluation of mitral regurgitation: The twenty-four signs of severe mitral regurgitation. Cardiol Clin 1993;11:399–408. 53. Smith MD, Harrison MR, Pinton R, et al: Regurgitant jet size by transesophageal
compared with transthoracic Doppler color flow imaging. Circulation 1991;83:79–86. 54. Klein AL, Obarski TP, Stewart WJ, et al: Transesophageal Doppler echocardiography of pulmonary venous flow: A new marker of mitral regurgitation severity. J Am Coll Cardiol 1991;18:518–526. 55. Hynes MS, Tam JL, Burwash IG, et al: Predictive value of pulmonary venous flow
patterns in detecting mitral regurgitation and left ventricular abnormalities. Can J Cardiol 1999;15:665–670. 56. Grayburn PA, Fehske W, Omran H, et al: Multiplane transesophageal
echocardiographic assessment of mitral regurgitation by Doppler color flow mapping of the vena contracta. Am J Cardiol 1994;74:912–917. 57. Pu M, Vandervoort PM, Griffin BP, et al: Quantification of mitral regurgitation by
the proximal convergence method using transesophageal echocardiography: Clinical validation of a geometric correction for proximal flow constraint. Circulation 1995;92:2169–2177. 58. Marwick TH, Torelli J, Obarski T, et al: Assessment of the mitral valve splitability
score by transthoracic and transesophageal echocardiography. Am J Cardiol 1991;68:1106–1107. 59. Stoddard MF, Prince CR, Tuman WL, et al: Angle of incidence does not affect accuracy of mitral stenosis area calculation by pressure half-time: Application to Doppler transesophageal echocardiography. Am Heart J 1994;127:1562–1572. 60. Degertekin M, Basaran Y, Gencbay M, et al: Validation of flow convergence
region method in assessing mitral valve area in the course of transthoracic and transesophageal echocardiographic studies. Am Heart J 1998;135:207–214. 61. Cormier B, Vahanian A, Michel PL, et al: Transesophageal echocardiography in
the assessment of percutaneous mitral commissurotomy. Eur Heart J 1991;12(suppl B):61–65. 62. Essop MR, Skudicky D, Sareli P: Diagnostic value of transesophageal versus
transthoracic echocardiography in discrete subaortic stenosis. Am J Cardiol 1992;70:962–963. 63. Meyerowitz CB, Jacobs LE, Kotler MN, et al: Assessment of aortic regurgitation
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 16
by transesophageal echocardiography: Correlation with angiographic determination. Echocardiography 1993;10:269–278. 64. Sutton DC, Kluger R, Ahmed SU, et al: Flow reversal in the descending aorta: A
guide to intraoperative assessment of aortic regurgitation with transesophageal echocardiography. J Thorac Cardiovasc Surg 1994;108:576–582. 20
65. Sato Y, Kawazoe K, Nasu M, et al: Clinical usefulness of the proximal isovelocity
surface area method using echocardiography in patients with eccentric aortic regurgitation. J Heart Valve Dis 1999;8:104–111. 66. Sato Y, Kawazoe K, Kamata J, et al: Clinical usefulness of the effective regurgitant
orifice area determined by transesophageal echocardiography in patients with eccentric aortic regurgitation. J Heart Valve Dis 1997;6:580–586. 67. Hoffmann R, Flachskampf FA, Hanrath P: Planimetry of orifice area in aortic stenosis using multiplane transesophageal echocardiography. J Am Coll Cardiol 1993;22:529–534. 68. Kim KS, Maxted W, Nanda NC, et al: Comparison of multiplane and biplane
transesophageal echocardiography in the assessment of aortic stenosis. Am J Cardiol 1997;79:436–441. 69. Cormier B, Iung B, Porte JM, et al: Value of multiplane transesophageal
echocardiography in determining aortic valve area in aortic stenosis. Am J Cardiol 1996;77:882–885. 70. Daniel WG, Mugge A, Grote J, et al: Comparison of transthoracic and
transesophageal echocardiography for detection of abnormalities of prosthetic and bioprosthetic valves in the mitral and aortic positions. Am J Cardiol 1993;71:210–215.
71. Alton ME, Pasierski TJ, Orsinelli DA, et al: Comparison of transthoracic and
transesophageal echocardiography in evaluation of 47 Starr-Edwards prosthetic valves. J Am Coll Cardiol 1992;20:1503–1511. 72. Daniel LB, Grigg LE, Weisel RD, et al: Comparison of transthoracic and
transesophageal assessment of prosthetic valve dysfunction. Echocardiography 1990;7:83–95.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 16
73. Khandheria BK, Seward JB, Oh JK, et al: Value and limitations of transesophageal
echocardiography in the assessment of mitral valve prosthesis. Circulation 1991;83:1956–1968. 74. Chaudhry FA, Herrera C, DeFrino PF, et al: Pathologic and angiographic
correlations of transesophageal echocardiography in the prosthetic heart valve dysfunction. Am Heart J 1991;122:1057–1064. 75. Karalis DG, Chandrasekaran K, Ross JJ Jr, et al: Single-plane transesophageal
echocardiography for assessing function of mechanical or bioprosthetic valves in the aortic valve position. Am J Cardiol 1992;69:1310–1315. 76. Gueret P, Vignon P, Fournier P, et al: Transesophageal echocardiography for the
diagnosis and management of nonobstructive thrombosis of mechanical mitral prosthesis. Circulation 1995;91:103–110. 77. Orsinelli DA, Pearson AC: Detection of prosthetic valve strands by
transesophageal echocardiography: Clinical significance in patients with suspected cardiac source of embolism. J Am Coll Cardiol 1995;26:1713–1718. 78. Barbetseas J, Nagueh SF, Pitsavos C, et al: Differentiating thrombus from pannus
formation in obstructed mechanical prosthetic valves: An evaluation of clinical, transthoracic and transesophageal echocardiographic parameters. J Am Coll Cardiol 1998;32:1410–1417. 79. Ozkan M, Kaymaz C, Kirma C, et al: Intravenous thrombolytic treatment of
mechanical prosthetic valve thrombosis: A study using serial transesophageal echocardiography. J Am Coll Cardiol 2000;35:1881–1889. 80. Tenenbaum A, Fisman EZ, Vered Z, et al: Failure of transesophageal
echocardiography to visualize a large mitral prosthesis vegetation detected solely by transthoracic echocardiography. J Am Soc Echocardiogr 1995;8:944–946. 81. Flachskampf FA, O'Shea JP, Griffin BP, et al: Patterns of transvalvular
regurgitation in normal mechanical prosthetic valves. J Am Coll Cardiol 1991;18:1493–1498. 82. Flachskampf FA, Hoffmann R, Franke A, et al: Does multiplane transesophageal
echocardiography improve the assessment of prosthetic valve regurgitation? J Am Soc Echocardiogr 1995;8:70–78. 83. Reisner SA, Meltzer RS: Normal values of prosthetic valve Doppler
echocardiographic parameters: A review. J Am Soc Echocardiogr 1998;11:201–210.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 16
84. Gorscan J III, Kenny WM, Diana P, et al: Transesophageal continuous-wave
Doppler to evaluate mitral prosthetic stenosis. Am Heart J 1991;121:911–914. 85. Baumgartner H, Khan S, DeRobertis M, et al: Effect of prosthetic aortic design on
the Doppler-catheter gradient correlation: An in vitro study of normal St. Jude, Medtronic-Hall, Starr-Edwards, and Hancock valves. J Am Coll Cardiol 1992;19:324– 332. 86. Durak DT, Lukes AS, Bright DK: New criteria for diagnosis of infective
endocarditis: Utilization of specific echocardiographic findings. Am J Med 1994;96:200–209. 87. Birmingham GD, Rahko PS, Ballantyne FE: Improved detection of infective
endocarditis with transesophageal echocardiography. Am Heart J 1992;123:774–781. 88. Erbel R, Rohmann S, Drexler M, et al: Improved diagnostic value of
echocardiography in patients with infective endocarditis by transesophageal approach: A prospective study. Eur Heart J 1988;9:43–53. 89. Taams MA, Gussenhoven EJ, Bos E, et al: Enhanced morphologic diagnosis in
infective endocarditis by transoesphageal echocardiography. Br Heart J 1990;63:109– 113. 90. Shively BK, Gurule FT, Roldan CA, et al: Diagnostic value of transesophageal
compared with transthoracic echocardiography in infective endocarditis. J Am Coll Cardiol 1991;18:391–397. 91. Mügge A, Daniel WG, Frank G, et al: Echocardiography in infective endocarditis:
Reassessment of prognostic implications of vegetation size determined by the transthoracic and the transesophageal approach. J Am Coll Cardiol 1989;14:631–638. 92. Shapiro SM, Young E, Ginzton LE, et al: Pulmonic valve endocarditis as an underdiagnosed disease: Role of transesophageal echocardiography. J Am Soc Echocardiogr 1992;5:48–51. 93. San Roman JA, Vilacosta I, Zamorano JL, et al: Transesophageal
echocardiography in right-sided endocarditis. J Am Coll Cardiol 1993;21:1226–1230. 94. Zabalgoitia M, Herrera CJ, Chaudhry FA, et al: Improvement in the diagnosis of
bioprosthetic valve dysfunction by transesophageal echocardiography. J Heart Valve Dis 1993;2:595–603. 95. Lowry RW, Zoghbi WA, Baker WB, et al: Clinical impact of transesophageal
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 16
echocardiography in the diagnosis and management of infective endocarditis. Am J Cardiol 1994;73:1089–1091. 96. Lindner JR, Case RA, Dent JM, et al: Diagnostic value of echocardiography in
suspected endocarditis: An evaluation based on the pretest probability of disease. Circulation 1996;93:730–736. 97. Sochowski RA, Chan K-L: Implication of negative results on a monoplane
transesophageal echocardiographic study in patients with suspected infective endocarditis. J Am Coll Cardiol 1994;21:216–221. 98. Daniel WG, Mugge A, Martin RP, et al: Improvement in the diagnosis of abscesses
associated with endocarditis by transesophageal echocardiography. N Engl J Med 1991;324:795–800. 99. Massey WM, Samdarshi TE, Nanda NC, et al: Serial documentation of changes in
a mitral valve vegetation progressing to abscess rupture and fistula formation by transesophageal echocardiography. Am Heart J 1992;124:241–248. 100. Castro SD, Cartoni D, d'Amati G, et al: Diagnostic accuracy of transthoracic and
multiplane transesophageal echocardiography for valvular perforation in acute infective endocarditis: Correlation with anatomic findings. Clin Infect Dis 2000;30:825–826. 101. Vilacosta I, San Roman JA, Sarria C, et al: Clinical, anatomic, and
echocardiographic characteristics of aneurysms of the mitral valve. Am J Cardiol 1999;84:110–113. 102. Rohmann S, Erhel R, Darius H, et al: Effect of antibiotic treatment on vegetation
size and complication rate in infective endocarditis. Clin Cardiol 1997;20:132–140. 103. Cerebral Embolism Task Force: Cardiogenic brain embolism: The second report
of the Cerebral Embolism Task Force. Arch Neurol 1989;46:727–743. 104. Kapral MK, Silver FL, with the Canadian Task Force on Preventive Health Care:
Preventive health care, 1999 update: 2. Echocardiography for the detection of a cardiac source of embolus in patients with stroke. Can Med Assoc J 1999;161:989– 996. 105. Dressler FA, Labovitz AJ: Systemic arterial emboli and cardiac masses:
Assessment with transesophageal echocardiography. Cardiol Clin 1993;11:447–460. 106. Hwang JJ, Chen JJ, Lin SC, et al: Diagnostic accuracy of transesophageal
echocardiography for detecting left atrial thrombi in patients with rheumatic heart
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 16
disease having undergone mitral valve operations. Am J Cardiol 1993;72:677–681. 107. Manning WJ, Weintraub RM, Wakomonski CA, et al: Accuracy of
transesophageal echocardiography for identifying left atrial thrombi. A prospective intraoperative study. Ann Intern Med 1995;123:817–822. 21
108. Mugge A, Daniel WG, Haverich A, et al: Diagnosis of noninfective cardiac mass
lesions by two-dimensional echocardiography: Comparison of the transthoracic and transesophageal approaches. Circulation 1991;83:70–78. 109. Chen C, Koschyk D, Hamm C, et al: Usefulness of transesophageal
echocardiography in identifying small left ventricular apical thrombus. J Am Coll Cardiol 1993;21:208–215. 110. Black IW, Hopkins AP, Lee LCL, et al: Left atrial spontaneous echo contrast: A
clinical transesophageal echocardiographic analysis. J Am Coll Cardiol 1991;18:398– 404. 111. Rittoo D, Cotter L: Detection of a small left atrial myxoma: Value and limitations
of four imaging modalities. J Am Soc Echocardiogr 1997;10:874–876. 112. Mügge A, Daniel WG, Haverich A, et al: Diagnoses of noninfective cardiac mass
lesions by two-dimensional echocardiography: Comparison of the transthoracic and transesophageal approaches. Circulation 1991;83:70–78. 113. Siostrzonek P, Zangeneh M, Gössinger H, et al: Comparison of transesophageal
and transthoracic contrast echocardiography for detection of a patent foramen ovale. Am J Cardiol 1991;68:1247–1249. 114. Pearson AC, Nagelhout D, Castello R, et al: Atrial septal aneurysm and stroke: A
transesophageal echocardiographic study. J Am Coll Cardiol 1991;18:1223–1229. 115. Hausmann D, Mügge A, Daniel WG: Identification of patent foramen ovale
permitting paradoxical embolism. J Am Coll Cardiol 1995;26:1030–1038. 116. Tunick PA, Kronzon I: Atheromas of the thoracic aorta: Clinical and therapeutic
update. J Am Coll Cardiol 2000;35:545–554. 117. Willens HJ, Kessler KM: Transesophageal echocardiography in the diagnosis of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 16
diseases of the thoracic aorta: Part II—atherosclerotic and traumatic diseases of the aorta. Chest 2000;117:233–243. 118. Rauh G, Fischereder M, Spengel FA: Transesophageal echocardiography in
patients with focal cerebral ischemia of unknown cause. Stroke 1996;27:691–694. 119. Mehta RH, Helmcke F, Nanda NC, et al: Transesophageal Doppler color flow
mapping assessment of atrial septal defect. J Am Coll Cardiol 1990;16;1010–1016. 120. Mugge A, Daniel WG, Angermann C, et al: Atrial septal aneurysm in adult
patients: A multicenter study using transthoracic and transesophageal echocardiography. Circulation 1995;91:2785–2792. 121. Rittoo D, Sutherland GR, Shaw TR: Quantification of left-to-right shunting and
defect size after balloon mitral commissurotomy using biplane transesophageal echocardiography, color flow Doppler mapping, and the principle of proximal flow convergence. Circulation 1993;87:1591–1603. 122. Ewert P, Berger F, Daehnert I, et al: Transcatheter closure of atrial septal defects
without fluoroscopy: Feasibility of a new method. Circulation 2000;101:847–849. 123. Engberding R, Daniel WG, Erbel R, et al: Diagnosis of heart tumours by
transoesophageal echocardiography: A multicentre study in 154 patients. Eur Heart J 1993;14:1223–1228. 124. Beaver TA, Robb JF, Teufel EJ, et al: Right ventricular outflow tract obstruction
in an older woman: Facilitated diagnosis with transesophageal echocardiographyguided biopsy. J Am Soc Echocardiogr 2000;13:622–625. 125. Cigarrao JE, Isselbacher EM, DeSanctis RW, et al: Diagnostic imaging in the
evaluation of suspected aortic dissection: Old standards and new directions. N Engl J Med 1993:328:35–43. 126. Nienaber CA, von Kodolitsch Y, Nicolas V, et al: The diagnosis of thoracic aortic
dissection by noninvasive imaging procedures. N Engl J Med 1993;328:1–9. 127. Bansal RC, Chandrasekaran K, Ayala K, et al: Frequency and explanation of false
negative diagnosis of aortic dissection by aortography and transesophageal echocardiography. J Am Coll Cardiol 1995;25:1393–1401. 128. Willens HJ, Kessler KM: Transesophageal echocardiography in the diagnosis of
diseases of the thoracic aorta: Part I—aortic dissection, aortic intramural hematoma, and penetrating atherosclerotic ulcer of the aorta. Chest 2000;116:1772–1779.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 16
129. Keren A, Kim CB, Hu BS, et al: Accuracy of biplane and multiplane
transesophageal echocardiography in diagnosis of typical acute aortic dissection and intramural hematoma. J Am Coll Cardiol 1996;28:627–636. 130. Sommer T, Fehske W, Holzkuecht N, et al: Aortic dissection: A comparative
study of diagnosis with spiral CT, multiplanar transesophageal echocardiography and MR imaging. Radiology 1996;199:347–352. 131. Masani ND, Banning AP, Jones RA, et al: Follow-up of chronic thoracic aortic
dissection: Comparison of transesophageal echocardiography and magnetic resonance imaging. Am Heart J 1996;131:1156–1163. 132. Vilacosta I, San Roman JA, Aragoncillo P, et al: Penetrating atherosclerotic aortic
ulcer: Documentation by transesophageal echocardiography. J Am Coll Cardiol 1998;32:83–89. 133. Smith MD, Cassidy JM, Souther S, et al: Transesophageal echocardiography in
the diagnosis of traumatic rupture of the aorta. N Engl J Med 1995;332:356–362. 134. Ahrar K, Smith DC, Bansal RC, et al: Angiography in blunt thoracic aortic injury.
J Trauma 1997;42:665–669. 135. Ritter SB: Transesophageal real-time echocardiography in infants and children
with congenital heart disease. J Am Coll Cardiol 1991;18:569–580. 136. Weintraub R, Shiota T, Elkadi T, et al: Transesophageal echocardiography in
infants and children with congenital heart disease. Circulation 1992;86:711–722. 137. Sreeram N, Stumper OF, Kaulitz R, et al: Comparative value of transthoracic and
transesophageal echocardiography in the assessment of congenital abnormalities of the atrioventricular junction. J Am Coll Cardiol 1990;16:1205–1214. 138. Kaulitz R, Stümper OFW, Geuskens R, et al: Comparative values of the
precordial and transesophageal approaches in the echocardiographic evaluation of atrial baffle function after an atrial correction procedure. Am J Coll Cardiol 1990;16:686–694. 139. Stümper O, Sutherland GR, Geuskens R, et al: Transesophageal echocardiography
in evaluation and management after a Fontan procedure. J Am Coll Cardiol 1991;17:1152–1160. 140. Engvall J, Sjoqvist L, Nylander E, et al: Biplane transoesophageal
echocardiography, transthoracic Doppler, and magnetic resonance imaging in the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 16
assessment of coarctation of the aorta. Eur Heart J 1995;10:1399–1409. 141. Andrade A, Vargas-Barron J, Rijlaarsdam M, et al: Utility of transesophageal
echocardiography in the examination of adult patients with patent ductus arteriosus. Am Heart J 1995;130:543–546. 142. Tardif JC, Vannon MA, Taylor K, et al: Delineation of extended lengths of coronary arteries by multiplane transesophageal echocardiography. J Am Coll Cardiol 1994;24:909–919. 143. Reichert SL, Visser CA, Koolen JJ, et al: Transesophageal examination of the left
coronary artery with a 7.5 MHz annular array two-dimensional color flow Doppler transducer. J Am Soc Echocardiogr 1990;3:118–124. 144. Samdarshi TE, Nanda NC, Gatewood RP Jr, et al: Usefulness and limitations of
transesophageal echocardiography in the assessment of proximal coronary artery stenosis. J Am Coll Cardiol 1992;19:572–580. 145. Yoshida K, Yoshikawa J, Hozumi T, et al: Detection of left main coronary artery
stenosis by transesophageal color Doppler and two-dimensional echocardiography. Circulation 1990;81:1271–1276. 146. Firstenberg MS, Greenberg NL, Lin SS, et al: Transesophageal echocardiography
assessment of severe ostial left main coronary stenosis. J Am Soc Echocardiogr 2000;13:696–698. 147. Panza JA: Transesophageal echocardiography with stress for the evaluation of
patients with coronary artery disease. Cardiol Clin 1999;17:501–520. 148. Madu EC: Transesophageal dobutamine stress echocardiography in the evaluation
of myocardial ischemia in morbidly obese subjects. Chest 2000;117;657–661. 149. Lin FC, Chang HJ, Chern MS, et al: Multiplane transesophageal
echocardiography in the diagnosis of congenital coronary artery fistula. Am Heart J 1995;130:1236–1242. 150. Hutchison SJ, Smalling RG, Albornoz M, et al: Comparison of transthoracic and
transesophageal echocardiography in clinically overt or suspected pericardial heart disease. Am J Cardiol 1994;74:962–965. 151. Klein AL, Cohen GI, Pietrolungo JF, et al: Differentiation of constrictive
pericarditis from restrictive cardiomyopathy by Doppler transesophageal echocardiographic measurements of respiratory variations in pulmonary venous flow. J Am Coll Cardiol 1993;22:1935–1943.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 15 di 16
22
152. Ling LH, Oh JK, Tei C, et al: Pericardial thickness measured with
transesophageal echocardiography: Feasibility and potential clinical usefulness. J Am Coll Cardiol 1997;29:1317–1323. 153. Heidenreich PA, Stainback RF, Redberg RF, et al: Transesophageal
echocardiography predicts mortality in critically ill patients with unexplained hypotension. J Am Coll Cardiol 1995;26:152–158. 154. Vignon P, Mentec H, Terre S, et al: Diagnostic accuracy and therapeutic impact of
transthoracic and transesophageal echocardiography in mechanically ventilated patients in the ICU. Chest 1994;106;1829–1834. 155. Dewan NA, Gayasaddin M, Angelillo VA, et al: Persistent hypoxemia due to
patent foramen ovale in a patient with adult respiratory distress syndrome. Chest 1986;89:611. 156. Bansal RC, Marsa RJ, Holland D, et al: Severe hypoxemia due to shunting
through a patent foramen ovale: A correctable complication of right ventricular infarction. J Am Coll Cardiol 1985;15:499–504. 157. American Society of Anesthesiologists and the Society of Cardiovascular Anesthesiologists Task Force on Transesophageal Echocardiography: Practice guidelines for perioperative transesophageal echocardiography. Anesthesiology 1996;84:986–1006. 158. Kolev N, Brase R, Swanevelder J, et al: The influence of transoesophageal
echocardiography on intra-operative decision making: A European multicentre study. European Perioperative TOE Research Group. Anaesthesia 1998;53:767–773. 159. Park SH, Kim MA, Hyon MS: The advantages of on-line transesophageal
echocardiography guide during percutaneous balloon mitral valvuloplasty. J Am Soc Echocardiogr 2000;13:26–34. 160. Pytlewski G, Georgeson S, Burke J, et al: Endomyocardial biopsy under
transesophageal echocardiographic guidance can be safely performed in the critically ill cardiac transplant recipient. Am J Cardiol 1994;73:1019–1020. 161. Kantoch MJ, Frost GF, Robertson MA: Use of transesophageal echocardiography
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 16 di 16
in radiofrequency catheter ablation in children and adolescents. Can J Cardiol 1998;14:519–523. 162. Tumbarello R, Sanna A, Cardu G, et al: Usefulness of transesophageal
echocardiography in the pediatric catheterization laboratory. Am J Cardiol 1993;71:1321–1325. 163. van der Velde ME, Sanders SP, Keane JF, et al: Transesophageal
echocardiographic guidance of transcatheter ventricular septal defect closure. J Am Coll Cardiol 1994;23:1660–1665. 164. McElhinney DB, Burch GH, Kung GC, et al: Echocardiographic guidance for
transcatheter coil embolization of congenital coronary arterial fistulas in children. Pediatr Cardiol 2000;21:253–258. 165. Cheung YF, Leung MP, Lee J, et al: An evolving role of transesophageal
echocardiography for the monitoring of interventional catheterization in children. Clin Cardiol 1999;22:804–810. 166. Manning WJ, Silverman DI, Gordon SP, et al: Cardioversion from atrial
fibrillation without prolonged anticoagulation with use of transesophageal echocardiography to exclude the presence of atrial thrombi. N Engl J Med 1993;328:750–755. 167. Moreyra E, Finkelhor RS, Cebul RD: Limitations of transesophageal
echocardiography in the risk assessment of patients before nonanticoagulated cardioversion from atrial fibrillation and flutter: An analysis of pooled trials. Am Heart J 1995:129:71–75. 168. Greenfield SM, Webster GJ, Brar AS, et al: Assessment of residual gastric
volume and thirst in patients who drink before gastroscopy. Gut 1996;39:360–362. 169. Khandheria BK, Seward JB, Tajik AJ: Concise review for primary-care
physicians: Transesophageal echocardiography. Mayo Clin Proc 1994;69:856–863. 170. Grauer SE, Giraud GD: Toxic methemoglobinemia after topical anesthesia for
transesophageal echocardiography. J Am Soc Echocardiogr 1996;9:874–876.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/14.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
23
Chapter 2 - Monitoring Ventricular Function in the Operating Room Impact on Clinical Outcome Donald C. Oxorn MD
Since being introduced into anesthetic practice in the late 1980s, transesophageal echocardiography (TEE) for intraoperative monitoring during cardiac surgery has gained wide acceptance. In 1995, Poterack[1] reported a national survey of anesthesia residency program directors in which 91% reported its use. TEE is relatively noninvasive, can be used in the vast majority of patients, and does not interfere physically with most surgical procedures. In some centers, TEE is used routinely for all cases involving cardiopulmonary bypass, whereas it is used more selectively at others. The usefulness of TEE during noncardiac surgery has been less thoroughly investigated, although if one extrapolates from the experience with hemodynamically unstable intensive care unit patients,[2] its utility in the differential diagnosis of intraoperative hemodynamic instability would appear intuitive. In this chapter, after I offer a general approach to and a personal philosophy on intraoperative TEE, the focus will be on the assessment of cardiac
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
function in the setting of both cardiac and noncardiac surgery. In addition, the impact intraoperative TEE has had on the quality of perioperative care is discussed. Intraoperative assessment of valvular function, chamber size, masses, and great vessels are covered in other sections of the book.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/15.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
An Approach to Intraoperative Transesophageal Echocardiography Intraoperative TEE has become inextricably linked with cardiac anesthesiology. Over the past decade, guidelines for physician training in TEE have been directed primarily at cardiologists[3] [4] [5] and have stressed a background in transthoracic echocardiography, the acquisition of both cognitive and technical skills, and an ongoing program of maintenance of competence (see Chapter 42) . What is the standard that anesthesiologists should hold themselves up to? No written standard exists, although there are several distinct levels of expertise. Some individuals have taken advanced training that has included the performance and interpretation of surface studies under the tutelage of cardiologists and sonographers; others have studied TEE in the operating room during cardiac anesthesiology fellowships or "on the job"; and many have taught themselves by observation in the operating room, attendance at educational symposia, and the study of text and videotape. The educational program for intraoperative TEE at the Cleveland Clinic is a joint effort between cardiac anesthesiologists and cardiologists and is designed to train individuals to the highest level.[6] There are now two examinations of special competence under the auspices of the National Board of Echocardiography. The curriculum for the intraoperative examination focuses primarily on TEE, whereas the curriculum for the examination in general echocardiography emphasizes a broad knowledge of most aspects of echocardiography, both transthoracic and transesophageal. I believe that anesthesiologists who wish to practice intraoperative TEE should adhere to several tenets. Firstly, although attendance at lectures and reviewing written matter is important, didactic material should not
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
24
replace direct interaction with knowledgeable colleagues. My personal experience suggests that beginning with transthoracic echocardiography is an invaluable first step. Secondly, it must be recognized that there will be different comfort levels among practitioners, and consultation with more skilled colleagues, be they anesthesiologists or cardiologists, should be encouraged. Even if intraoperative TEE is used solely as a monitor of ventricular function, it behooves the practitioner to perform a complete examination and to recognize that unexpected pathologic lesions, when present, may necessitate consultation. And lastly, all practitioners who are involved with TEE would serve themselves and their institutions by striving to pass one of the examinations of special competence. A working group of the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists developed guidelines for performing a comprehensive intraoperative TEE examination.[7] Their recommendations are summarized in Figure 2-1 (Figure Not Available) . It is the committee's contention that if the practitioner performs a careful and systematized examination every time the probe is inserted, the chance of missing important findings is minimized, and the potential for teaching is enhanced. Figure 2-1 (Figure Not Available) Twenty cross-sectional views composing the recommended comprehensive transesophageal echocardiography examination. The icon adjacent to each view indicates the approximate multiplane angle. ME, midesophageal; LAX, long axis; TG, transgastric; SAX, short axis; AV, aortic valve; RV, right ventricle; asc, ascending; desc, descending; UE, upper esophageal. (From Shanewise JS, Cheung AT, Aronson S, et al: Anesth Analg 1999;89:870.)
Book Text
Pagina 1 di 14
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Evaluation of Intraoperative Ventricular Function Left Ventricular Filling In the operating room, rapidity is needed in the assessment of preload during periods of hemodynamic instability. Since the introduction of the pulmonary artery catheter in the 1970s, measurement of pulmonary capillary wedge pressure as a surrogate of left ventricular end diastolic volume has been the intraoperative practice standard; however, it is recognized that especially in situations of decreased ventricular compliance, the pulmonary capillary wedge pressure is an inaccurate estimate of preload.[8] TEE has the potential to refine this measurement by allowing Doppler estimation of left atrial pressure, two-dimensional measurement of left ventricular cross-sectional area, and calculation of left ventricular volume. Left Atrial Pressure
Left atrial pressure can be estimated with Doppler TEE by several methods. If mitral regurgitation is present, 25
measurement of the peak velocity of the regurgitant jet and application of the modified Bernoulli equation allows calculation of the left ventriculoatrial pressure gradient; subtraction of this number from the peak systolic blood pressure yields left atrial pressure[9] (Fig. 2-2) . Certain mitral inflow and pulmonary venous variables also correlate with left atrial pressure; Kuecherer et al[10] found that in patients undergoing cardiovascular surgery, changes in the systolic fraction of the pulmonary venous tracing correlated inversely and strongly with pulmonary capillary wedge pressure, and they theorized that this related to decreased atrial compliance. Nomura et al[11] found that in patients with ejection fractions
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 14
less than 35%, the deceleration time of the early velocity of mitral inflow correlated with pulmonary capillary wedge pressure, and that a deceleration time greater than 150 msec was strongly predictive of a pulmonary capillary wedge pressure of less than 10 mm Hg. There are a number of caveats related to the intraoperative estimation of left atrial pressure with TEE. Patients with a rhythm other than sinus or with valvular regurgitation were excluded in most studies; these are the very patients in whom preload estimates are often crucial. In suitable patients, correlations but not absolute values of left atrial pressure are usually yielded. Use of the mitral regurgitation jet to calculate left atrial pressure dictates that mitral regurgitation must be present. And finally, an estimate of left atrial pressure, whether obtained by Doppler echocardiography or by pulmonary artery catheter, may still yield inaccurate estimates of preload in patients with decreased ventricular compliance. End-Diastolic Area and End-Systolic Area
A number of authors have examined the intraoperative relationship between end-diastolic and end-systolic area Figure 2-2 Measuring the peak velocity (V) of the mitral regurgitation (MR) jet and applying the modified Bernoulli equation yields a pressure gradient (PG) between the left atrium and ventricle of 56 mm Hg. Subtracting this value from the systolic arterial pressure of 86 mm Hg gives a left atrial pressure (LAP) of 30 mm Hg. BP, blood pressure.
measured at the transgastric midpapillary level and cardiac volume status. Cheung et al[12] performed an elegant study examining the effect of graded hypovolemia produced by autologous blood collection on hemodynamic and TEE-derived indices of left ventricular preload in patients undergoing coronary artery bypass surgery. Patients with valvular insufficiency, rhythms other than sinus, and overt congestive heart failure were excluded. Patients were stratified on the basis of resting left ventricular function. Enddiastolic area, end-systolic area, pulmonary capillary wedge pressure, and measures of end-diastolic and end-systolic wall stress decreased linearly as blood volume was reduced from 0 to 15% in all patients; however, in patients with impaired left ventricular function, only the TEE-derived indices maintained linearity (Fig. 2-3) (Figure Not Available) . Other studies have also demonstrated that single plane areas, although not
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 14
predictive of absolute left ventricular volumes,[13] [14] can generally be used to monitor for a trend toward increased or decreased volume.[15] [16] [17] It must also be remembered that the presence of a small end-diastolic area or end-systolic area does not always reflect decreased intravascular volume. Small left ventricular volumes can be seen with restrictions to filling, as in pericardial disease, or decreased right heart function, as in right ventricular infarction or large pulmonary embolus[18] (Fig. 2-4) . Patients presenting for cardiac surgery often have preexisting impairment of diastolic function. De Hert et al[19] obtained transmitral flow signals with TEE and high-fidelity recordings of left ventricular pressure in patients anesthetized for coronary bypass. A subset of patients was identified in whom leg elevation resulted in a decreased dP/dt; those same patients developed a restrictive pattern on mitral inflow. Diastolic function is worsened to a variable degree following cardiopulmonary bypass.[20] This explains the frequent inadequacy of left ventricular filling despite seemingly adequate filling pressures.
26
The presence of end-systolic obliteration of the left ventricular cavity, although usually associated with hypovolemia (Fig. 2-5) , may also be associated with increased inotropy, or redistribution of blood out of the thoracic cavity.[21] Left Ventricular Volumes
In an in vitro study using silicone rubber models of the left ventricle, the calculation of left ventricular volumes using multiplane TEE and the disk summation method[22] was found to be highly accurate.[23] However, problems related to the moving heart, exclusion of akinetic segments of the left ventricle, and difficulty in getting a true long-axis view of the left ventricle have led to disappointing Figure 2-3 (Figure Not Available) End-diastolic area (EDA) and end-systolic area (ESA) in response to graded hypovolemia yielded estimated blood volume (EBV) deficits of 0 to 15%. Patients had either normal left ventricular (LV) function or reduced LV function. Control patients were not subjected to hypovolemia. (From Cheung AT, Savino JS, Weiss SJ, et al: Anesthesiology 1994;81:376–387.)
Figure 2-4 Transgastric image of a transesophageal echocardiography
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 14
scan obtained in a patient who had suffered massive fat embolism. Increased pulmonary vascular resistance and subsequent right ventricular (RV) dilation led to impaired left ventricular (LV) filling.
results when used in the perioperative setting.[14] [24] Technologic advances such as three-dimensional TEE,[25] harmonic imaging,[26] and automated border detection may lead to improved intraoperative accuracy. In summary, the assessment of preload with intraoperative TEE is in most cases a semiquantitative estimate based on visual inspection of enddiastolic and end-systolic areas and on temporal comparison with the use of videotape or stored cine loops. Confounding conditions such as right ventricular failure or the administration of inotropic agents must be considered. Global Systolic Function Cardiac Output
Ventricular filling, contractility, wall stress, and heart rate all influence cardiac output. Thus, cardiac output is the measurement most often used in anesthetic and critical care practice as a guide to therapeutic manipulations of cardiac function. Despite its limitations,[27] [28] thermodilution cardiac output measurement has been considered the "gold standard" since being popularized in the early 1970s. Doppler transesophageal echocardiography has the potential to be used in the intraoperative setting for the continuous measurement of cardiac output. These methods utilize the concept that the cross-sectional area of a conduit within the cardiovascular system multiplied by the Doppler-derived timevelocity integral yields the stroke volume through that conduit. When the result is multiplied by heart rate, the product is cardiac output. Several important assumptions are inherent to this approach. Valid area formulas must be applicable to the anatomic site being analyzed. The velocity profile across the valve must be flat and devoid of skew.[29] [30] Whichever anatomic area is chosen, the ability to consistently obtain the image and to interrogate parallel to flow is mandatory. Pulmonary Artery.
With the probe at 0 degrees and retroflexed, the main pulmonary artery and pulmonic valve can be imaged at the base of the heart (Fig. 2-6) . This
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 14
27
Figure 2-5 Transesophageal echocardiogram from a hypovolemic patient. During systole, the posteromedial and anterolateral papillary muscles touch. LV, left ventricle; RV, right ventricle.
Figure 2-6 Imaging at the base of the heart of the main pulmonary artery (PA) and its branches. Pulsed Doppler velocity time integral (VTI) and diameter measurement are used to calculate stroke volume. MnGRAD, mean gradient; PGRAD, peak gradient; PV, pulmonary valve; Vmax, maximum velocity.
28
site has been examined with pulsed wave Doppler,[30] [31] [32] and in a study by Gorcsan et al,[33] using both pulsed wave and continuous wave methodologies, pulmonary artery diameter was measured just distal to the pulmonic valve. Interobserver variability was low in all studies, and correlation with thermodilution was strong in all but the study by Muhiudeen et al,[31] in which patients with inaccurate thermodilution measurements may have been included. The major limitation with using the pulmonary artery is the inability to obtain an adequate two-dimensional image for diameter measurement in up to 25% of patients. Right Ventricular Outflow Tract.
With the probe turned rightward and flexed, the right ventricular outflow tract is imaged from the stomach between 0 and 120 degrees (Fig. 2-7) . Imaging frequency must usually be reduced to ensure optimal penetration. Maslow et al[34] found excellent correlation between cardiac output calculated with pulsed wave Doppler and thermodilution. Patients with pulmonary hypertension, significant tricuspid regurgitation, and non-sinus rhythms were excluded. Again, in a significant percentage (16%) of patients, the two-dimensional image was not suitable. Left Ventricular Outflow Tract.
With the probe in the stomach, turned leftward, in the flexed position, and at low imaging frequency, the aortic valve and left ventricular outflow tract
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 14
can usually be imaged between 0 and 140 degrees (Fig. 2-8) (Figure Not Available) . Imaging from the stomach allows parallel pulsed Doppler interrogation of the left ventricular outflow tract, and its diameter, obtained from either the stomach or the midesophageal 120-degree view, allows calculation of the cross-sectional area and cardiac output (Fig. 2-9) . Strong correlation with thermodilution and low interobserver variability have been described.[35] [36] To avoid contamination of the Doppler signal by the region of flow acceleration adjacent to the aortic Figure 2-7 Pulsed wave (PW) Doppler measurement from the right ventricular outflow tract (RVOT) (color plate). RV, right ventricle.
valve orifice, the sample volume must be placed precisely in the left ventricular outflow tract. Aortic Valve.
Using the transgastric view described for left ventricular outflow tract, several investigators have studied the combination of continuous wave Doppler positioned through the left ventricular outflow tract and aortic valve and cross-sectional area of the aortic valve using the triangle method (Fig. 2-10) .[37] [38] In brief, the triangular shape of the aortic valve orifice at mid-systole is assumed to represent the time averaged value for the aortic valve area. Strong correlation with thermodilution and low interobserver variability were again obtained (Fig. 2-11) . As continuous wave Doppler is used, it is important to confirm that the maximal peak velocity is occurring at the aortic valve. The triangle method is limited to patients with unrestricted aortic valve opening. Mitral Valve.
Using the mitral valve for calculation of cardiac output has the advantages of consistent imaging and parallel Doppler alignment. However, the saddle shape of the mitral annulus makes the area measurement unpredictable, and the cross-sectional velocity skew[29] is of concern when using pulsed wave Doppler. Practical Considerations.
For intraoperative transesophageal Doppler calculation of cardiac output, the left ventricular outflow tract method is the most reproducible. Adjustments in the degree of probe flexion and imaging angle should be
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 14
made to ensure that the aortic valve and ascending aorta are clearly visualized and that the Doppler intercept angle is small (see Fig. 2-9) . Several measurements should be made and averaged, this being especially important when dealing with rhythms other than sinus. In practical terms, Doppler measurement of cardiac output is used when a pulmonary artery catheter is not in place, or when conditions such as severe tricuspid regurgitation render thermodilution inaccurate. There is a need for 29
Figure 2-8 (Figure Not Available) Transesophageal echocardiography imaging from the stomach allows parallel alignment with the ascending aorta. (From Perrino AC Jr., Harris SN, Luther MA: Anesthesiology 1998;89:350–357.) Figure 2-9 Transgastric imaging of the left ventricular outflow tract (LVOT). The ascending aorta is well visualized, and the Doppler intercept angle is small. Pulsed Doppler velocity time integral (VTI) and diameter measurement are used to calculate stroke volume. MnGRAD, mean gradient; PGRAD, peak gradient; Vmax, maximum velocity.
30
Figure 2-10 The triangle method of aortic valve area measurement. (From Darmon PL, Hillel Z, Mogtader A, et al: Anesthesiology 1994;80:796–805.)
further validation of this approach in patients with a spectrum of cardiovascular diseases. Ejection Fraction and Stroke Volume
Although it is somewhat load dependent and therefore not a pure index of "left ventricular function,"[39] ejection fraction is often assumed to reflect ventricular contractility. During intraoperative TEE, the fractional area of change measured at the transgastric midpapillary level is often used interchangeably with ejection fraction, although gauging volume in a potentially asymmetric Figure 2-11 Regression analysis: thermodilution cardiac output (TCO)
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 14
and Doppler cardiac output (DCO) using the aortic valve triangle method. (From Darmon PL, Hillel Z, Mogtader A, et al: Anesthesiology 1994;80:796– 805.)
chamber based on a measure of area has obvious limitations.[40] [41] A number of studies report the relationship between TEE-derived fractional area of change and radionuclide-derived ejection fraction. Clements et al[42] examined the relationship in 12 patients having abdominal aortic aneurysm surgery. There was excellent correlation in patients with both normal and abnormal left ventricular function. In patients with ventricular dyssynergy, fractional area of change led to a slight overestimate of ejection fraction. Urbanowicz et al[13] found strong correlation in 10 patients following coronary artery bypass grafting. In a series of 15 patients following coronary artery bypass grafting, Ryan et al[14] measured TEE ejection fraction using volumes calculated from the modified Simpson's and arealength methods[43] in addition to TEE-derived fractional area of change and radionuclide-derived ejection fraction. Unlike previous studies, variability was calculated and found to be small and not significantly different between the three measurement techniques. Not surprisingly, the TEE volumetric results were more representative of radionuclide ejection fraction than fractional area of change. Smith et al[24] also found that ejection fraction based on TEE volumetric methods were comparable to those obtained with angiography. In an attempt to develop online methods of intraoperative functional assessment, the technique of automated border detection has been used (see Chapter 7) . Automated border detection is based on the principle of acoustic quantification of ultrasonic back scatter signals to detect the bloodtissue interface and thereby define the endocardial edge.[44] Measurements correlate closely to those obtained by manual tracing of the endocardial border. [45] [46] [47] Gorcsan et al[17] examined stroke area, defined as the difference between end-systolic area and end-diastolic area measured at the midpapillary level, and compared the results to stroke volume measured in the ascending aorta by an electromagnetic flow probe in nine patients undergoing coronary artery bypass. Preoperative left ventricular function was largely preserved. Measurements were made before and after cardiopulmonary bypass. There was a strong correlation between the measurements at all periods of the study. Katz et al[48] compared stroke volume as measured by thermodilution to stroke volume obtained with automated border detection determination of end-systolic and end-diastolic areas and volumetric formulas (Fig. 2-12) ; these latter measurements were
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 14
made at the two-chamber and four-chamber midesophageal views. There was a close correlation between stroke volumes obtained by the two methods, but whereas the two-chamber view led to an average underestimate of 0.4 L, the four-chamber view led to an average underestimate of 1.9 L. In a similar study, Greim et al[49] used the twochamber view alone. Directional changes in stroke volume between thermodilution and automated border detection again correlated closely; however, the automated border detection technique significantly underestimated stroke volume. Ejection fraction has been estimated using automated border detection derived measurements of fractional area of change at the midpapillary level and compared to radionuclide-derived ejection fraction.[45] [46] [47] Although the directionality of change was significantly 31
Figure 2-12 An example of transesophageal echocardiography automated border detection from the four-chamber view with ventricular volume estimated on line by the area length method. (From Katz WE, Gasior TA, Reddy SC, et al: Am Heart J 1994;128:389–396.)
correlated, fractional area of change derived by automated border detection consistently overestimated radionuclide-derived ejection fraction. It would appear that fractional area of change more closely estimates ejection fraction in patients with normal ventricular function. The use of TEE-derived volumetric data to estimate ejection fraction is more accurate, but the cumbersome calculations involved do not lend themselves to rapid intraoperative derivation. The use of automated border detection algorithms and programmed volume calculations may prove superior but are largely untested in clinical practice. At present, the intraoperative assessment of ejection fraction is impractical, and stroke volume measurement is best accomplished with either Doppler or thermodilution methodology. Contractility
The end-systolic pressure-volume relationship and resultant end-systolic elastance defines contractility in a load-independent fashion[50] and would therefore be of potential use in the estimation of intraoperative left ventricle contractility and in the quantification of changes resulting from manipulations such as cardiopulmonary bypass.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 14
A number of surrogates of this relationship have been described to facilitate the practical acquisition of this information in an operating room setting. The substitution of femoral arterial pressure for left ventricular end-systolic pressure,[51] end-systolic area for end-systolic volume,[20] [52] [53] and endsystolic wall stress for end-systolic pressure[53] have been made. Although these substituted measurements are not construed as replacements for traditional measures of pressure and volume, their directional change suggests that in cardiac surgical patients undergoing cardiopulmonary bypass, they may be used as an alternative way of assessing loadindependent left ventricular function. The changes in contractility as a result of cardiopulmonary bypass[20] [54] and the administration of anesthetic agents[52] appear better assessed with estimates of end-systolic elastance than with more traditional indices of ventricular performance such as fractional area of change. Figure 2-13 illustrates the decrease in elastance (Ees) and increased chamber stiffness (Kc) that occur following cardiopulmonary bypass, and the mitigating effect of volume loading prior to bypass termination. At present, the methods for data analysis are prohibitively complex.[55] [56] Right Ventricular Function
In the setting of cardiopulmonary bypass, the evaluation of right ventricular function is important. Right ventricular dysfunction often occurs secondary to the inadequate delivery of cardioplegia[57] and to the embolization of intracardiac air down the right coronary artery following separation from cardiopulmonary bypass. The triangular shape of the right ventricle makes its global function hard to quantitate with TEE, and the abnormal septal motion often seen following cardiopulmonary bypass[58] compounds this difficulty. Rafferty et al[59] measured planimetered areas and major and minor axes in both long-axis and short-axis images of the right ventricle with TEE, before and after cardiopulmonary bypass. Unfortunately, the echo measurements, obtained offline, were not compared in a meaningful way to results obtained by thermodilution. Semiquantitative analysis of right ventricular function with TEE has also been attempted with the analysis of hepatic venous flow.[60] Many factors other than right ventricular systolic function, however, affect hepatic venous flow. In patients with diverse causes of right ventricular dysfunction, Vignon et al[61] demonstrated the ability to 32
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 14
Figure 2-13 Effect of cardiopulmonary bypass (CPB) on elastance (Ees) and chamber stiffness (Kc) of the left ventricle. Times of measurement were before the start of CPB (baseline); immediately after separation from CPB (time 0); and 5 minutes (time 5), 10 minutes (time 10), and 15 minutes (time 15) later. In protocol 1, preload was optimized just before the start of the separation procedure from CPB. In protocol 2, preload was optimized 10 minutes before the anticipated separation time. Data are shown as mean ± SEM. In protocol 1, ventricular function after separation from CPB was impaired, with a decrease in Ees and an increase in Kc, and a progressive improvement of ventricular function within the first 10 minutes after separation from CPB. These findings were not seen in protocol 2, in which ventricular function remained unchanged and comparable to baseline values. *Difference between both groups is statistically significant at P < 0.01. (From De Hert SG, Rodrigus IE, Haenen LR, et al: Anesthesiology 1996;85:1063–1075.)
quantitate right ventricular function with color kinesis and surface echocardiography. This method of examining right ventricular function has not been evaluated in an intraoperative setting with TEE. At the present time, TEE assessment of intraoperative right ventricular function is best accomplished by visual inspection and semiquantitative assessment in both the transgastric and the four-chamber views. Excellent transgastric views of all three leaflets of the tricuspid valve and the entire free wall of the right ventricle are best obtained by scanning at approximately 40 degrees (Fig. 2-14) . Regional Wall Motion The suggestion of a link between perioperative myocardial ischemia and cardiac morbidity[62] [63] has led to an intensive search for accurate methods of its intraoperative detection (Fig. 2-15) (Figure Not Available) . Visual inspection of ST segment changes has been the foundation upon which the newer technologies of automated ST analysis and TEE detection of regional wall motion abnormalities have been added. There are several points on which to judge the merits of TEE: Applicability, accuracy, reproducibility, cost, expertise required for interpretation, and prognostic importance. Segmental analysis is most frequently undertaken using the 16-segment model first proposed by Schiller et al[64] and later modified for TEE by Shanewise et al[7] (Fig. 2-16) (Figure Not Available) . Excellent inter- and intraobserver variability has been documented when six segments at the midpapillary level were analyzed offline by an anesthesiologist trained in
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 14
TEE and an echocardiographer.[65] The recognition that coronary occlusion leads to the immediate development of regional wall motion abnormalities[66] and their frequent regression following revascularization[67] has prompted investigators to examine the usefulness of intraoperative TEE as a monitor of ischemia. The paucity of contraindications to TEE means that it can be used in most patients undergoing general anesthesia. The midpapillary view is generally easy to obtain and demonstrates areas of myocardium subtended by the three major coronary arteries. Interpretation is rarely confounded by rhythm disturbances, as is the case for automated ST analysis. TEE cannot be used, however, in patients receiving regional anesthesia, and, because the probe is not inserted until after anesthetic induction, it cannot detect changes during this vulnerable period. Assessment of the accuracy of TEE in the detection of myocardial ischemia has been limited somewhat by the lack of a reliable reference standard. Smith et al[68] found that in patients at high risk of myocardial ischemia who were analyzed offline, wall motion changes could be detected Figure 2-14 Transgastric image of the right ventricular (RV) free wall, septum, and the leaflets of the tricuspid valve.
33
Figure 2-15 (Figure Not Available) Causes of ischemic changes on intraoperative monitors (color plate). (From Fleisher LA: Anesthesiology 2000;92:1183–1188.)
more quickly and commonly than ST segment changes. Conflicting studies[69] [70] regarding the prognostic importance of regional wall motion abnormalities were subsequently published. In a study by London et al,[69] 156 patients undergoing noncardiac surgery who were at high risk for coronary artery disease were studied. Specific clinical, electrocardiographic, or hemodynamic events prompted analysis of stored images. The number of new wall motion abnormalities detected was low, and discordance with electrocardiographic findings was significant (Table 2-1) . The number of postoperative cardiac complications was low. In the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 14
study by Leung et al,[70] patients undergoing coronary artery bypass were examined with electrocardiography and TEE. Although prebypass ischemia was rare, postbypass ischemia was more common and postoperative cardiovascular complications were associated more closely with TEE findings than with electrocardiography alone. It is now accepted that regional wall motion abnormalities, although often the result of myocardial ischemia, may be due to hypovolemia, tethering of nonischemic myocardium, and myocardial stunning after cardiopulmonary bypass.[71] [72] Offline analysis has been employed in most of the large-scale studies involving comparison of TEE with other methods of ischemia detection, but extrapolation to the accuracy of real-time TEE analysis should not be assumed. Regional wall motion abnormalities that subtend the anatomic distribution of coronary TABLE 2-1 -- Comparison of Transesophageal Echocardiography (TEE) and Intraoperative Electrocardiography (ECG) Monitoring for Myocardial Ischemia * TEE + TEE ECG + 8 (1 MI) 11 ECG 24 (2 MI, 1 UA) MI, myocardial infarction; UA, unstable angina. From London MJ, Tuban JF, Wong MG, et al: Anesthesiology 1990;73 (4):644. * P < 0.05.
34
Figure 2-16 (Figure Not Available) A 16-segment model of the left ventricle. A, Fourchamber views show the three septal and three lateral segments. B, Two-chamber views show the three anterior and three inferior segments. C, Long-axis views show the two anteroseptal and two posterior segments. D, Middle short-axis views show all six segments at the midpapillary level. E, Basal short-axis views show all six segments at the basal level. (From Shanewise JS, Cheung AT, Aronson S, et al: Anesth Analg 1999;89:870–884.)
artery flow are more often a result of ischemia than those that do not.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 14
Comunale et al[73] also documented the poor concordance between the TEE and electrocardiography and attributed this finding to the lack of standard definitions of significant regional wall motion abnormalities and ischemic ST changes, the exclusion of longitudinal TEE views, and the use of different models of segment nomenclature. The role of intraoperative monitoring of myocardial ischemia with TEE remains unclear. Intraoperative TEE monitoring is better suited to patients undergoing cardiac as opposed to noncardiac surgery and to those patients in whom more traditional methods of ischemia are deemed inadequate. The ability to monitor additional tomographic planes,[74] [75] the use of cine loops for comparison, and the advent of new technologies such as automated border detection and Doppler tissue imaging should improve accuracy. Regional wall motion abnormalities precede electrocardiographic changes, [76] and, once ischemia is diagnosed, TEE can be used to directly monitor the effects of intervention. Personnel with expertise in the online assessment of wall motion abnormalities are needed, however. Lastly, studies examining the outcomes of patients monitored for myocardial ischemia with TEE are needed. Intraoperative Assessment of Coronary Reserve Dobutamine stress echocardiography is a well-established technique for diagnosing coronary artery disease and predicting the improvement of dysfunctional myocardium postoperatively (see Chapter 14) .[77] [78] The ability to predict the reversibility of left ventricular dysfunction with the use of intraoperative low-dose dobutamine TEE was examined by Aronson et al[79] in the setting of coronary artery bypass grafting. The odds ratios for early and late improvement in myocardial function were 20.7 and 34.6 times higher if preoperative low-dose dobutamine produced improved function than if it did not. The instances when this intraoperative strategy might supplant the normal preoperative assessment of myocardial viability by transthoracic dobutamine stress echocardiography[78] or low-dose dobutamine technetium-99m sestamibi scintigraphy[80] have yet to be determined.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/17.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 7
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Use of Transesophageal Echocardiography to Monitor Intraoperative Cardiac Function in Specific Clinical Entities The use of TEE has improved our ability to intelligently manage postcardiopulmonary bypass instability. It has allowed us to understand the intraoperative changes that occur during some of the newer techniques in coronary revascularization and can guide us in placement of numerous intracardiac and intravascular devices. Its use in monitoring cardiac function during noncardiac surgery is most advantageous in the diagnosis of sudden and unexplained hemodynamic instability. Separation from Cardiopulmonary Bypass At the time of separation of the patient from cardiopulmonary bypass, the use of TEE may guide the anesthesiologist in the use of pharmacologic and nonpharmacologic therapies and can maximize the likelihood of a smooth transition. Intracardiac Air
Left-sided intracardiac air is ubiquitous following procedures in which leftsided chambers have been open to atmosphere and is identified by its characteristic "firefly" appearance. Air is often seen entering the left atrium from the pulmonary veins or enmeshed in the mitral subvalvular apparatus (Fig. 2-17) . Echocardiographic inspection is carried out in the fourchamber and transgastric long-axis views. Careful evacuation by the surgeon is important and involves suctioning on the aortic root vent or needle aspiration of the left ventricular apex to evacuate trapped pockets. As well as guiding evacuation, TEE is 35
Figure 2-17 Four-chamber midesophageal view. As the patient is being
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 7
separated from cardiopulmonary bypass (CPB), a pocket of air enmeshed in the left ventricular subvalvular apparatus is noted (asterisk), with numerous bubbles emanating from it. LA, left atrium; LV, left ventricle.
useful in diagnosing the consequences of embolization through the right coronary ostium, which results in ventricular dysfunction in a right coronary distribution. Cardiac Output
There are a number of potential causes of low cardiac output immediately following cardiopulmonary bypass: perioperative infarction, coronary air emboli, metabolic abnormalities, hypovolemia, left ventricular outflow tract obstruction, and inadequate myocardial protection. It seems intuitive that the yield of TEE when it is used during hemodynamic instability during and after cardiac surgery would be high. Two published series[81] [82] have demonstrated the myriad diagnoses that have been made TABLE 2-2 -- Relevant Intraoperative Transesophageal Echocardiograph Findings Categorized by Indication Indication, n
Finding Severe left ventricular dysfunction ± regional wall motion abnormality Aortic dissection ± aortic regurgitation Significant mitral regurgitation Intracardiac/great vessel shunt Hyperdynamic left ventricular function
HEMODYNAMIC SURGICAL INSTABILITY PLANNING TRAUMA HYPOXEMIA 15 2
1
13
4
2
1
1
2
TOTA NO. O PATIE
2 1
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 7
Severe right 2 1 ventricular dysfunction Extracardiac clot 2 Significant aortic 2 regurgitation Significant 1 tricuspid regurgitation Pericardial 1 tamponade No relevant 5 1 4 3 findings From Brandt RR, Oh JK, Abel MD, et al: J Am Soc Echocardiogr 1998;1 (10):972. and the ability to intervene on many (Table 2-2) . No attempt was made to compare TEE with other diagnostic modalities, although the speed with which information is made available appears hard to supersede. The use of myocardial contrast echocardiography has improved our understanding of the distribution of cardioplegia delivered by both anterograde and retrograde routes. The ability to predict the adequacy of delivery based on knowledge of coronary anatomy and the presence of angiographically demonstrated collateral flow is marginal at best.[83] It is also clear that retrograde cardioplegia does not reliably perfuse the right ventricular free wall,[57] [84] and, in some centers, this observation has led to a strategy of early cardioplegia administration down a vein graft to the right coronary artery.[85] In the future, the use of myocardial contrast echocardiography may help to 36
Figure 2-18 A, Transesophageal echocardiography to investigate hypoxia revealed an expanding ascending aortic aneurysm with main pulmonary artery (PA) compression. B, Normal image for comparison. LA, left atrium; SVC, superior vena cava.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 7
differentiate postbypass stunning, which would be treated with cardiopulmonary support, from graft obstruction, which would be treated with surgical correction.[86] [87] Off-Pump Coronary Bypass Surgery The off-pump bypass surgical approach to coronary revascularization involves bypassing coronary arteries without cardiopulmonary bypass, otherwise known as the "beating heart" operation. TEE can detect regional wall motion abnormalities during intermittent coronary occlusion and cardiac lifting, which, if persistent, may necessitate the institution of cardiopulmonary bypass. The use of color kinesis to better define regional wall motion abnormalities intraoperatively has been described [88] but is limited somewhat by cardiac translocation during surgical manipulation. Cardiac Function in Noncardiac Surgery The use of TEE to monitor cardiac function in noncardiac surgery has been described largely in anecdotal form. In most of the case reports, unexplained hypotension prompted the use of TEE, and subsequent diagnoses have included massive pulmonary embolism,[89] [90] intracardiac tumor extension,[91] retroperitoneal hemorrhage,[92] cardiac tamponade,[93] main pulmonary artery obstruction by an expanding aortic aneurysm[94] (Fig. 2-18) , traumatic cardiac injury,[95] [96] [97] ventilator-induced systemic air embolism,[98] [99] and a case of venous air embolism during pelvic surgery, which resulted in pulseless electrical activity until open cardiac aspiration was undertaken (Fig. 2-19) . Positioning of Intravascular Devices Intraoperative TEE can be used to guide the positioning of a number of intravascular devices: Central Venous Pressure Air Aspiration Catheters.
These are often used during sitting craniotomies to aspirate air that has gained access to the venous circulation. Correct positioning is at the right atrial-superior vena caval junction, and imaging is best in the midesophagus with rightward rotation and a transducer angle of approximately 90 degrees (Fig. 2-20) . Intra-aortic Balloon Pump.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 7
The benefits of intra-aortic balloon pump have been demonstrated with TEE and include improved left ventricular function and decreased wall stress. [100] [101] The balloon pump is best imaged in the descending aorta in a vertical plane. Correct positioning is at the inferior border of the transverse aortic arch.[102] Once the tip of the balloon is visualized at a transducer angle of approximately 90 degrees, the probe marking at the teeth is noted. The probe is slowly withdrawn until the left subclavian artery orifice is seen; the marking is again noted. The distance between the balloon and the subclavian orifice should be approximately 5 cm (Fig. 2-21) . Left Ventricular Assist Device.
As the left ventricular assist device withdraws blood from the left ventricle, left atrial pressure falls below right atrial pressure. It is important Figure 2-19 During pelvic surgery, massive amounts of air are seen entering the right atrium (RA) via the inferior vena cava (IVC).
37
Figure 2-20 A catheter inserted from the arm is positioned at the junction of the right atrium (RA) and superior vena cava (SVC) to evacuate any air that gains access to the venous circulation during sitting craniotomy. LA, left atrium.
to determine whether a patent foramen ovale is present, as right-to-left shunting will invariably occur. The orifice of the ventricular apical cannula should be imaged in the four-chamber view, and the lack of obstruction by adjacent walls should be ascertained[103] (Fig. 2-22) . Right Ventricular Assist Device.
In positioning the right atrial drainage cannula, it is preferable to avoid impingement on the tricuspid valve (Fig. 2-23) . Minimally Invasive Cardiac Surgery.
Port access surgery
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 7
Figure 2-21 Intra-aortic balloon pump (IABP) positioned in the descending thoracic aorta. The left subclavian artery is visualized and not encroached upon.
involves the performance of a variety of surgical procedures through small thoracic ports or very limited incisions. Cannulation for the purposes of cardiopulmonary bypass and cardioplegic arrest is achieved percutaneously. TEE is used to position the various endovascular catheters and to monitor their position during surgery[104] [105] (Fig. 2-24) (Figure Not Available) . Some surgeons prefer an upper sternotomy incision. Cannulation is then achieved directly, except for the retrograde cardioplegia cannula, 38
Figure 2-22 The drainage component of the left ventricular assist device (LVAD) is seen to freely enter the apical region of the left ventricle (LV). LA, left atrium.
which is inserted through blind right atrial puncture and maneuvered into the coronary sinus under TEE guidance[106] (Fig. 2-25) . Left Ventricular Vent.
A left ventricular vent is placed through the right upper pulmonary vein into the left atrium and advanced through the mitral valve into the left ventricle to drain excess ventricular volume on bypass (Fig. 2-26) . Transplant Surgery Transesophageal echocardiography can be used to assess the function of the donor heart prior to procurement and after separation from cardiopulmonary bypass, when Figure 2-23 (color plate.) The drainage component of the right ventricular assist device (RVAD) enters the right atrium (RA) through the appendage (left, arrow). The tip is seen in the right atrium and free of the tricuspid valve on TEE (right). PA, pulmonary artery. Figure 2-24 (Figure Not Available) The various endovascular cardiopulmonary
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 7
bypass catheters for post-access surgery are depicted. (From Siegel LC, St. Goar FG, Stevens JH, et al.: Circulation 1997;96:562–568.)
the effects of the ischemic time may become evident. During lung transplantation, the use of TEE has been described in the evaluation of vascular anastomoses,[107] and a recent case report documented a diagnosis of post-transplant pulmonary venous obstruction.[108] Laparoscopic Surgery As laparoscopic surgery has grown in its application, so has the realization that the associated pneumoperitoneum 39
Figure 2-25 During minimally invasive cardiac surgery, the coronary sinus catheter is seen entering the right atrium (RA) and passing into the coronary sinus. LA, left atrium.
leads to increased left ventricular wall stress[109] and decreased fractional area of change.[110] Following release of the pneumoperitoneum, higher than baseline fractional area of change has been described.[110] These hemodynamic alterations have been attributed to the physical effect of increased intra-abdominal pressure and to the associated neurohumoral changes. TEE has also been used to monitor for intraoperative gas embolization.[111]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/18.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 4
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Transesophageal Echocardiography as a Monitor of Intraoperative Ventricular Function: Impact on Perioperative Complications and Cost-Effectiveness Medical technology assessment has become an important step in the introduction and clinical use of increasingly sophisticated and costly methods of monitoring and diagnosis.[112] In anesthetic and critical care practice, no technology has engendered more controversy than the use of pulmonary artery catheterization, which has become an established monitor of cardiovascular function, despite the lack of significant outcome and costeffectiveness data.[113] [114] The use of TEE to monitor intraoperative ventricular function varies significantly between institutions[1] [115] and relates in part to the experience of the operator, the type of surgical procedure, and the cardiopulmonary reserve of the patient. For TEE to be deemed an effective mode of intraoperative monitoring, it must be shown to provide at least the same if not more information than currently accepted monitoring techniques, have a reasonable cost profile, involve acceptable risk, and alter outcome in a positive way. Kato et al[116] demonstrates the ability to diagnose and effectively manage intraoperative ischemia under TEE guidance, but, as is the case with many subsequent studies, their study falls short in not evaluating the effects of intraoperative TEE monitoring on patient outcome. Several studies have addressed the impact of intraoperative TEE monitoring of ventricular function during coronary bypass surgery. Bergquist et al[117] studied the concordance between real-time intraoperative TEE interpretation by five cardiac anesthesiologists and offline analysis by two blinded investigators in the assessment of left ventricular filling, ejection fraction area, and regional wall motion. Results obtained by the two methods were within 10% of each other 75% of the time with respect to ejection fraction and filling. The accuracy of regional assessment
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 4
Figure 2-26 A left ventricular (LV) vent is seen passing into the left atrium (LA) via a right-sided pulmonary vein. MV, mitral valve.
40
TABLE 2-3 -- Surgical Management Alterations During Coronary Artery Bypass Grafting Based on Transesophageal Echocardiographic Findings
Before CPB, n 2 NA NA 0 8
Before CPB After CPB After Total No. Separation, Separation, CC, of n n n Patients NA NA NA 2 NA 3 1 4 NA NA 2 2 0 0 1 1 2 3 1 12
Alteration Rush to CPB Return to CPB Reopen LVAD/ECMO Additional redo grafts IABP 4 3 2 0 9 CC, chest closure; CPB, cardiopulmonary bypass; ECMO, extracorporeal membrane oxygenation; IABP, intra-aortic balloon pump; LVAD, left ventricular assist device; NA, not applicable. From Savage RM, Lytle BW, Aronson S, et al: Ann Thorac Surg 1997;64(2):368. was variable: more accurate for normal than for abnormal wall motion and better in anesthesiologists with more advanced echocardiographic training. In the second part of the study,[118] TEE was found to be the most important factor in guiding hemodynamic interventions in 17% of cases examined. What is lacking is a clear demonstration that the TEE assessments were correct and that the same interventions would not have been undertaken if guided by more traditional monitors. Cost and outcome were not examined. Savage et al,[87] at the Cleveland Clinic, examined the use of intraoperative
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 4
TEE monitoring in a group of high-risk patients undergoing coronary artery bypass grafting. As well as documenting numerous management changes related to TEE-derived information (Table 2-3) , they documented lower short-term morbidity and mortality rates as compared with a historical group of patients with similar severity scores[119] who were not monitored with TEE (Table 2-4) . An individual not part of the anesthetic or surgical team read the TEE scan; it is uncertain whether someone involved in direct patient management would have as readily garnered the information. In studies from Australia,[120] Europe,[121] Canada,[122] and India,[123] the realtime accrual of information with TEE was demonstrated to be of value in the management of hemodynamic perturbations and the planning of the surgical procedure in coronary bypass grafting as well as other cardiac surgical procedures Table 2-5 , Table 2-6 , and Table 2-7 ). No assessment of the effect of intraoperative TEE TABLE 2-4 -- Patient Outcomes with and without Intraoperative Transesophageal Echocardiography (TEE) Management without TEE 478 64.8 5.9 18 (3.8) 14 (3.5)
Variable Management with TEE Patients, n 82 Age, y 68.4 Severity score 6.1 Hospital deaths, n (%) 1 (1.2) Myocardial Infarction, n 1 (1.2) (%) Cardiac morbidity, n (%) 1 (1.2) 7 (1.5) ICU CNS morbidity, n (%) 3 (3.6) 18 (3.8) Hospital CNS morbidity, n 1 (1.2) 16 (3.3) (%) CNS, central nervous system; ICU, intensive care unit. From Savage RM, Lytle BW, Aronson S, et al: Ann Thorac Surg 1997; 64(2):368.
monitoring on patient outcome was made. These studies are summarized in Table 2-8 . The impact of monitoring of ventricular function during noncardiac surgery
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 4
has not been studied as closely. In a retrospective review by Suriani et al, [124] the use of TEE was associated with some alterations in anesthetic and surgical management in a majority of cases. However, the indications for TEE were subjective, and neither the cost-effectiveness nor the effect on outcome was studied.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/19.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 5
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Summary Has the burden of proof been met with respect to intraoperative TEE as a monitor of ventricular function? If one adopts the premise that rigorously designed, randomized, controlled clinical trials are society's benchmark,[125] TABLE 2-5 -- Impact of Routine Transesophageal Echocardiographic (TEE) Findings on Medical and Surgical Management: Coronary Artery Bypass Grafting After Cardiopulmonary Bypass (N = 120) Clinical Problem/TEE Finding (no. of patients) Consequence (no. of patients) Acute SWMA (8), acute Graft revision (3), papaverine (1), SWMA and medical therapy (5) moderate/severe mitral regurgitation (1) IABP not in optimal position (2) IABP not in descending aorta ST depression (II and V5)/no SWMA (3) Pulmonary
Impact E (3) * †
IABP advanced
I (6) V (2) ‡
IABP reinserted
V (1)
De-cannulation-good outcome
I (3)
Medical therapy for ischemia, not protamine reaction
I (1)
hypertension 3 minutes post protamine/
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 5
widespread SWMA, moderate to severe mitral regurgitation E, essential; I, informative; IABP, intra-aortic balloon pump; SWMA, segmental wall motion abnormality; V, valuable. From Sutton DC, Kluger R: Anaesth Intensive Care 1998;26(3):287. * One patient also classified as valuable for IABP not in descending aorta. † One patient also classified as informative for ST depression without SWMA. ‡ Two patients also classified as informative in problems separating from CPB.
41
TABLE 2-6 -- Influence of Intraoperative Transesophageal Echocardiogra as the Driving Force on Interventions Compared with Other Monito Monitor Intervention, n (%) TEE ELECTROCARDIOGRAPHY Fluid bolus 275 0 (28) Anti-ischemic 207 114 (31) therapy (56) Vasopressor 56 3 (1) or inotrope (16) therapy Change in 4 0 anesthetic (2) depth Vasodilator 6 9 (6) therapy (4) Antiarrythmic 0 55 (89) therapy
ARTERIAL CATHETER 129 (13)
PULMONARY ARTERY OTH CATHETER 73 (7)
11 (3)
31 (8)
183 (51)
27 (7)
164 (78)
2 (1)
96 (68)
13 (9)
0
0
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 5
Surgical 9 17 (33) 12 (23) 0 intervention (17) Miscellaneous 3 2 (6) 27 (75) 3 (8) (8) Total 560 200 (9) 622 (28) 149 (7) (25) From Kolev N, Brase R, Swanefelder J, et al: Anaesthesia 1998;53(8):76 *Indicates that the interventions were not based on information from the four monitors studied. More than half of these interventions were transfusion of blood for low hematocrit.
TABLE 2-7 -- Summary of Surgical Modifications Related to the Intraoperative Use of Transesophageal Echocardiography Modification Number Return on bypass for revision of coronary artery bypass graft 4 Modification of planned surgery: Valvular replacement cancelled 5 Valvular replacement or repair 11 Pleural drainage 3 Detection of air emboli before aortic unclamping 2 Surgical exploration for hemodynamic instability 7 Femoral artery bypass for aortic dissection 2 Others: Ventricular aneurysm resection 1 Aortoplasty 1 Cancellation of aortic dissection (diagnostic error) 1 Left ventricular assist device 1 Total 38 From Couture P, Denault AY, McKenty S, et al: Can J Anaesth 2000;47 (1):20.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 5
TABLE 2-8 -- Summary of Studies Examining the Alterations in Therapy During Cardiac Surgery with the Use of Intraoperative Transesophageal Echocardiography Altered Therapy, Study Population Surgery n/% 98/17% of all Bergquist n = 75, 584 C[118] Interventions revasc interventions et al Savage et n = 82 "High CSurgical change: [87] al risk" revasc 27/33% of patients Hemodynamic change: 42/51% of patients Sutton & n = 120 C16/13% of all patients Kluger revasc
Outcome Reported No Compared to historical controls
No
[120]
C-all 560/25% of all No Kolev et n = 224, [121] 2232 NC interventions al interventions Couture n = 851 C-all 125/15% of all No [122] et al patients Mishra et n = 5016 C-all 1146/23% of all No [123] al patients C-all, coronary and non-coronary cardiac surgery; C-revasc, coronary revascularizations; NC, noncardiac surgery.
42
then the jury is still out. The cost-effectiveness data that have been generated by studies of the use of TEE in congenital cardiac surgery,[126] preparation for elective cardioversion,[127] and determination of antibiotic treatment duration in endocarditis[128] have not yet demonstrated the benefits of monitoring of ventricular function in cardiac or noncardiac surgery. The data collected for studies are often reviewed offline, whereas clinical utility comes from online interpretation. Outcome data are scarce and sometimes conflicting. The "division of labor" in the operating room is also important, as too much attention to TEE may distract the anesthesiologist from other
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 5
monitoring tasks.[129] Transesophageal echocardiography is an expensive undertaking and is not practically carried into the postoperative phase of patient management. Case studies and observational data cannot be dismissed, however. [130] [131] TEE has a unique ability to facilitate the rapid diagnosis of circulatory instability, and a number of observational studies show that information gained during intraoperative TEE frequently guides subsequent therapeutic maneuvers. In response, most fellowships in cardiac anesthesiology have incorporated instruction in the monitoring of ventricular function with intraoperative TEE. It must be emphasized that appropriate physician training and quality assurance[132] are crucial to the correct interpretation of data. Further technologic advancements such as color kinesis, automated border detection, and the use of loop storage for comparison should improve accuracy. Studies examining cost-effectiveness and outcome are needed.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/20.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 13
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
References 1. Poterack KA: Who uses transesophageal echocardiography in the operating room?
Anesth Analg 1995;80:454. 2. Poelaert JI, Trouerbach J, De Buyzere M, et al: Evaluation of transesophageal
echocardiography as a diagnostic and therapeutic aid in a critical care setting. Chest 1995;107:774. 3. Chan KL, Alvarez N, Cujec B, et al: Standards for adult echocardiography training.
Canadian Cardiovascular Society Committee. Can J Cardiol 1996;12:473. 4. Eisenberg MJ, Rice S, Schiller NB: Guidelines for physician training in advanced
cardiac procedures: The importance of case mix [editorial]. J Am Coll Cardiol 1994;23:1723. 5. Pearlman AS, Gardin JM, Martin RP, et al: Guidelines for physician training in
transesophageal echocardiography: Recommendations of the American Society of Echocardiography Committee for Physician Training in Echocardiography. J Am Soc Echocardiogr 1992;5:187. 6. Savage RM, Licina MG, Koch CG, et al: Educational program for intraoperative
transesophageal echocardiography. Anesth Analg 1995;81:399. 7. Shanewise JS, Cheung AT, Aronson S, et al: ASE/SCA guidelines for performing a
comprehensive intraoperative multiplane transesophageal echocardiography examination: Recommendations of the American Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. Anesth Analg 1999;89:870. 8. Hoeft A, Schorn B, Weyland A, et al: Bedside assessment of intravascular volume
status in patients undergoing coronary bypass surgery. Anesthesiology 1994;81:76.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 13
9. Gorcsan JD, Snow FR, Paulsen W, et al: Noninvasive estimation of left atrial
pressure in patients with congestive heart failure and mitral regurgitation by Doppler echocardiography. Am Heart J 1991;121(3 Pt 1):858. 10. Kuecherer HF, Muhiudeen IA, Kusumoto FM, et al: Estimation of mean left atrial
pressure from transesophageal pulsed Doppler echocardiography of pulmonary venous flow. Circulation 1990;82:1127. 11. Nomura M, Hillel Z, Shih H, et al: The association between Doppler transmitral
flow variables measured by transesophageal echocardiography and pulmonary capillary wedge pressure. Anesth Analg 1997;84:491. 12. Cheung AT, Savino JS, Weiss SJ, et al: Echocardiographic and hemodynamic
indexes of left ventricular preload in patients with normal and abnormal ventricular function. Anesthesiology 1994;81:376. 13. Urbanowicz JH, Shaaban MJ, Cohen NH, et al: Comparison of transesophageal
echocardiographic and scintigraphic estimates of left ventricular end-diastolic volume index and ejection fraction in patients following coronary artery bypass grafting. Anesthesiology 1990;72:607. 14. Ryan T, Burwash I, Lu J, et al: The agreement between ventricular volumes and ejection fraction by transesophageal echocardiography or a combined radionuclear and thermodilution technique in patients after coronary artery surgery. J Cardiothorac Vasc Anesth 1996;10:323. 15. Tousignant CP, Walsh F, Mazer CD: The use of transesophageal echocardiography
for preload assessment in critically ill patients. Anesth Analg 2000;90:351. 16. Hinder F, Poelaert JI, Schmidt C, et al: Assessment of cardiovascular volume status
by transoesophageal echocardiography and dye dilution during cardiac surgery. Eur J Anaesthesiol 1998;15:633. 17. Gorcsan JD, Gasior TA, Mandarino WA, et al: On-line estimation of changes in
left ventricular stroke volume by transesophageal echocardiographic automated border detection in patients undergoing coronary artery bypass grafting. Am J Cardiol 1993;72:721. 18. Jardin F, Dubourg O, Bourdarias JP: Echocardiographic pattern of acute cor
pulmonale. Chest 1997;111:209. 19. De Hert SG, Vander Linden PJ, ten Broecke PW, et al: Assessment of lengthdependent regulation of myocardial function in coronary surgery patients using
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 13
transmitral flow velocity patterns. Anesthesiology 2000;93:374. 20. De Hert SG, Rodrigus IE, Haenen LR, et al.: Recovery of systolic and diastolic left
ventricular function early after cardiopulmonary bypass. Anesthesiology 1996;85:1063. 21. Leung JM, Levine EH: Left ventricular end-systolic cavity obliteration as an
estimate of intraoperative hypovolemia. Anesthesiology 1994;81:1102. 22. Erbel R, Krebs W, Henn G, et al: Comparison of single-plane and biplane volume
determination by two-dimensional echocardiography. 1. Asymmetric model hearts. Eur Heart J 1982;3:469. 23. Krebs W, Klues HG, Steinert S, et al: Left ventricular volume calculations using a
multiplanar transoesophageal echoprobe; in vitro validation and comparison with biplane angiography. Eur Heart J 1996;17:1279. 24. Smith MD, MacPhail B, Harrison MR, et al: Value and limitations of transesophageal echocardiography in determination of left ventricular volumes and ejection fraction. J Am Coll Cardiol 1992;19:1213. 25. Hozumi T, Yoshikawa J, Yoshida K, et al: Three-dimensional echocardiographic
measurement of left ventricular volumes and ejection fraction using a multiplane transesophageal probe in patients. Am J Cardiol 1996;78:1077. 26. Rocchi G, de Jong N, Galema TW, et al: Effect of harmonic imaging without
contrast on image quality of transesophageal echocardiography. Am J Cardiol 1999;84:1132. 27. Schuster AH, Nanda NC: Doppler echocardiographic measurement of cardiac
output: Comparison with a non-golden standard. Am J Cardiol 1984;53:257. 28. Levett JM, Replogle RL: Thermodilution cardiac output: A critical analysis and
review of the literature. J Surg Res 1979;27:392. 29. Samstad SO, Torp HG, Linker DT, et al: Cross sectional early mitral flow velocity
profiles from colour Doppler. Br Heart J 1989;62:177. 30. Savino JS, Troianos CA, Aukburg S, et al: Measurement of pulmonary blood flow
with transesophageal two-dimensional and Doppler echocardiography. Anesthesiology 1991;75:445. 43
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 13
31. Muhiudeen IA, Kuecherer HF, Lee E, et al: Intraoperative estimation of cardiac
output by transesophageal pulsed Doppler echocardiography. Anesthesiology 1991;74:9. 32. Izzat MBB, Regragui IA, Wilde P, et al: Transesophageal echocardiographic measurements of cardiac output in cardiac surgical patients. Ann Thorac Surg 1994;58:1486. 33. Gorcsan JD, Diana P, Ball BA, et al: Intraoperative determination of cardiac output
by transesophageal continuous wave Doppler. Am Heart J 1992;123:171. 34. Maslow A, Comunale ME, Haering JM, et al: Pulsed wave Doppler measurement
of cardiac output from the right ventricular outflow tract. Anesth Analg 1996;83:466. 35. Stoddard MF, Prince CR, Ammash N, et al: Pulsed Doppler transesophageal
echocardiographic determination of cardiac output in human beings: Comparison with thermodilution technique. Am Heart J 1993;126:956. 36. Descorps-Declere A, Smail N, Vigue B, et al: Transgastric, pulsed Doppler
echocardiographic determination of cardiac output. Intensive Care Med 1996;22:34. 37. Perrino AC Jr, Harris SN, Luther MA: Intraoperative determination of cardiac
output using multiplane transesophageal echocardiography: A comparison to thermodilution. Anesthesiology 1998;89:350. 38. Darmon PL, Hillel Z, Mogtader A, et al: Cardiac output by transesophageal
echocardiography using continuous-wave Doppler across the aortic valve. Anesthesiology 1994;80:796. 39. Robotham JL, Takata M, Berman M, et al: Ejection fraction revisited.
Anesthesiology 1991;74:172. 40. Schiller NB, Acquatella H, Ports TA, et al: Left ventricular volume from paired
biplane two-dimensional echocardiography. Circulation 1979;60:547. 41. Teichholz LE, Kreulen T, Herman MV, et al: Problems in echocardiographic
volume determinations: Echocardiographic-angiographic correlations in the presence or absence of asynergy. Am J Cardiol 1976;37:7. 42. Clements FM, Harpole DH, Quill T, et al: Estimation of left ventricular volume
and ejection fraction by two-dimensional transoesophageal echocardiography:
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 13
Comparison of short axis imaging and simultaneous radionuclide angiography. Br J Anaesth 1990;64:331. 43. Wyatt HL, Haendchen RV, Meerbaum S, et al: Assessment of quantitative methods
for 2-dimensional echocardiography. Am J Cardiol 1983;52:396. 44. Perez JE, Waggoner AD, Barzilai B, et al: On-line assessment of ventricular function by automatic boundary detection and ultrasonic backscatter imaging. J Am Coll Cardiol 1992;19:313. 45. Cahalan MK, Ionescu P, Melton HE Jr, et al: Automated real-time analysis of
intraoperative transesophageal echocardiograms. Anesthesiology 1993;78:477. 46. Liu N, Darmon PL, Saada M, et al: Comparison between radionuclide ejection
fraction and fractional area changes derived from transesophageal echocardiography using automated border detection. Anesthesiology 1996;85:468. 47. Perrino AC Jr, Luther MA, O'Connor TZ, et al: Automated echocardiographic analysis. Examination of serial intraoperative measurements. Anesthesiology 1995;83:285. 48. Katz WE, Gasior TA, Reddy SC, et al: Utility and limitations of biplane
transesophageal echocardiographic automated border detection for estimation of left ventricular stroke volume and cardiac output. Am Heart J 1994;128:389. 49. Greim CA, Roewer N, Laux G, et al: On-line estimation of left ventricular stroke
volume using transoesophageal echocardiography and acoustic quantification. Br J Anaesth 1996;77:365. 50. Sagawa K: The end-systolic pressure-volume relation of the ventricle: Definition,
modifications and clinical use. Circulation 1981;63:1223. 51. Gorcsan J 3rd, Denault A, Gasior TA, et al: Rapid estimation of left ventricular
contractility from end-systolic relations by echocardiographic automated border detection and femoral arterial pressure. Anesthesiology 1994;81:553. 52. Declerck C, Hillel Z, Shih H, et al: A comparison of left ventricular performance
indices measured by transesophageal echocardiography with automated border detection. Anesthesiology 1998;89:341. 53. O'Kelly BF, Tubau JF, Knight AA, et al: Measurement of left ventricular
contractility using transesophageal echocardiography in patients undergoing coronary artery bypass grafting. The Study of Perioperative Ischemia (SPI) Research Group. Am Heart J 1991;122(4 Pt 1):1041.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 13
54. Gorcsan J 3rd, Gasior TA, Mandarino WA, et al: Assessment of the immediate effects of cardiopulmonary bypass on left ventricular performance by on-line pressurearea relations. Circulation 1994;89:180. 55. Deneault LG, Kancel MJ, Denault A, et al: A system for the on-line acquisition,
visualization, and analysis of pressure-area loops. Comput Biomed Res 1994;27:61. 56. Shih H, Hillel Z, Declerck C, et al: An algorithm for real-time, continuous
evaluation of left ventricular mechanics by single-beat estimation of arterial and ventricular elastance. J Clin Monit 1997;13:157. 57. Winkelmann J, Aronson S, Young CJ, et al: Retrograde-delivered cardioplegia is not distributed equally to the right ventricular free wall and septum. J Cardiothorac Vasc Anesth 1995;9:135. 58. Wranne B, Pinto FJ, Siegel LC, et al: Abnormal postoperative interventricular
motion: New intraoperative transesophageal echocardiographic evidence supports a novel hypothesis. Am Heart J 1993;126:161. 59. Rafferty T, Durkin M, Harris S, et al: Transesophageal two-dimensional
echocardiographic analysis of right ventricular systolic performance indices during coronary artery bypass grafting. J Cardiothorac Vasc Anesth 1993;7:160. 60. Nomura T, Lebowitz L, Koide Y, et al: Evaluation of hepatic venous flow using
transesophageal echocardiography in coronary artery bypass surgery: An index of right ventricular function. J Cardiothorac Vasc Anesth 1995;9:9. 61. Vignon P, Weinert L, Mor-Avi V, et al: Quantitative assessment of regional right
ventricular function with color kinesis. Am J Respir Crit Care Med 1999;159:1949. 62. Slogoff S, Keats AS: Does perioperative myocardial ischemia lead to postoperative
myocardial infarction? Anesthesiology 1985;62:107. 63. Fleisher LA: Real-time intraoperative monitoring of myocardial ischemia in
noncardiac surgery. Anesthesiology 2000;92:1183. 64. Schiller NB, Shah PM, Crawford M, et al: Recommendations for quantitation of
the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of TwoDimensional Echocardiograms. J Am Soc Echocardiogr 1989;2:358. 65. Couture P, Denault AY, Carignan SHP, et al: Intraoperative detection of segmental
wall motion abnormalities with transesophageal echocardiography. Can J Anaesth
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 13
1999;46:827. 66. Tennant R, Wiggers CJ: The effect of coronary occlusion on myocardiol
contraction. Am J Physiol 1935;112:351. 67. Koh TW, Pepper JR, Gibson DG: Early changes in left ventricular anterior wall
dynamics and coordination after coronary artery surgery. Heart 1997;78:291. 68. Smith JS, Cahalan MK, Benefiel DJ, et al: Intraoperative detection of myocardial
ischemia in high-risk patients: Electrocardiography versus two-dimensional transesophageal echocardiography. Circulation 1985;72:1015. 69. London MJ, Tubau JF, Wong MG, et al: The "natural history" of segmental wall
motion abnormalities in patients undergoing noncardiac surgery. S.P.I. Research Group. Anesthesiology 1990;73:644. 70. Leung JM, O'Kelly B, Browner WS, et al: Prognostic importance of postbypass
regional wall-motion abnormalities in patients undergoing coronary artery bypass graft surgery. SPI Research Group. Anesthesiology 1989;71:16. 71. Leung JM, O'Kelly BF, Mangano DT: Relationship of regional wall motion
abnormalities to hemodynamic indices of myocardial oxygen supply and demand in patients undergoing CABG. Anesthesiology 1990;73:802. 72. Seeberger MD, Cahalan MK, Rouine-Rapp K, et al: Acute hypovolemia may cause
segmental wall motion abnormalities in the absence of myocardial ischemia. Anesth Analg 1997;85:1252. 73. Comunale MEHP, Body SC, Ley C, et al: The concordance of intraoperative left ventricular wall-motion abnormalities and electrocardiographic S-T segment changes: Association with outcome after coronary revascularization. Multicenter Study of Perioperative Ischemia (McSPI) Research Group. Anesthesiology 1998;88:945. 44
74. Koide Y, Keehn L, Nomura T, et al: Relationship of regional wall motion
abnormalities detected by biplane transesophageal echocardiography and electrocardiographic changes in patients undergoing coronary artery bypass graft surgery. J Cardiothorac Vasc Anesth 1996;10:719. 75. Rouine-Rapp K, Ionescu P, Balea M, et al: Detection of intraoperative segmental
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 13
wall-motion abnormalities by transesophageal echocardiography: The incremental value of additional cross sections in the transverse and longitudinal planes. Anesth Analg 1996;83:1141. 76. Hauser AM, Gangadharan V, Ramos RG, et al: Sequence of mechanical,
electrocardiographic and clinical effects of repeated coronary artery occlusion in human beings: Echocardiographic observations during coronary angioplasty. J Am Coll Cardiol 1985;5(2 Pt 1):193. 77. Geleijnse ML, Fioretti PM, Roelandt JR: Methodology, feasibility, safety and
diagnostic accuracy of dobutamine stress echocardiography. J Am Coll Cardiol 1997;30:595. 78. Elhendy A, Cornel JH, Roelandt JR, et al: Impact of severity of coronary artery
stenosis and the collateral circulation on the functional outcome of dyssynergic myocardium after revascularization in patients with healed myocardial infarction and chronic left ventricular dysfunction. Am J Cardiol 1997;79:883. 79. Aronson S, Dupont F, Savage R, et al: Changes in regional myocardial function
after coronary artery bypass graft surgery are predicted by intraoperative low-dose dobutamine echocardiography. Anesthesiology 2000;93:685. 80. Leoncini M, Marcucci G, Sciagra R, et al: Comparison of baseline and low-dose
dobutamine technetium-99m sestamibi scintigraphy with low-dose dobutamine echocardiography for predicting functional recovery after revascularization. Am J Cardiol 2000;86:153. 81. Chan KL: Transesophageal echocardiography for assessing cause of hypotension
after cardiac surgery. Am J Cardiol 1988;62:1142. 82. Brandt RR, Oh JK, Abel MD, et al: Role of emergency intraoperative
transesophageal echocardiography. J Am Soc Echocardiogr 1998;11:972. 83. Aronson S, Jacobsohn E, Savage RHP, et al: The influence of collateral flow on the
antegrade and retrograde distribution of cardioplegia in patients with an occluded right coronary artery. Anesthesiology 1998;89:1099. 84. Allen BS, Winkelmann JW, Hanafy H, et al: Retrograde cardioplegia does not
adequately perfuse the right ventricle. J Thorac Cardiovasc Surg 1995;109:1116. 85. Borger MA, Wei KS, Weisel RD, et al: Myocardial perfusion during warm
antegrade and retrograde cardioplegia: A contrast echo study. Ann Thorac Surg 1999;68:955.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 13
86. Aronson S, Savage R, Toledano A, et al: Identifying the cause of left ventricular
systolic dysfunction after coronary artery bypass surgery: The role of myocardial contrast echocardiography. J Cardiothorac Vasc Anesth 1998;12:512. 87. Savage RM, Lytle BW, Aronson S, et al: Intraoperative echocardiography is
indicated in high-risk coronary artery bypass grafting. Ann Thorac Surg 1997;64:368. 88. Kotoh K, Watanabe G, Ueyama K, et al: On-line assessment of regional ventricular
wall motion by transesophageal echocardiography with color kinesis during minimally invasive coronary artery bypass grafting. J Thorac Cardiovasc Surg 1999;117:912. 89. Langeron O, Goarin JP, Pansard JL, et al: Massive intraoperative pulmonary
embolism: Diagnosis with transesophageal two-dimensional echocardiography. Anesth Analg 1992;74:148. 90. Pharo GH, Andonakakis A, Chandrasekaren K, et al: Survival from catastrophic
intraoperative pulmonary embolism. Anesth Analg 1995;81:188. 91. Plowman AN, Bolsin SN, Patrick AJ: Unusual cause of intraoperative hypotension
diagnosed with transoesophageal echocardiography in a patient with renal cell carcinoma. Anaesth Intensive Care 1999;27:63. 92. Yamaura K, Okamoto H, Maekawa T, et al: Detection of retroperitoneal
hemorrhage by transesophageal echocardiography during cardiac surgery. Can J Anaesth 1999;46:169. 93. Hsin ST, Luk HN, Lin SM, et al: Detection of iatrogenic cardiac tamponade by
transesophageal echocardiography during vena cava filter procedure. Can J Anaesth 2000;47:638. 94. Jacka M, Oxorn DC: Pulmonary artery obstruction by aortic aneurysm mimicking
pulmonary embolism. Anesth Analg 1995;80:185. 95. Chavanon O, Dutheil V, Hacini R, et al: Treatment of severe cardiac contusion
with a left ventricular assist device in a patient with multiple trauma. J Thorac Cardiovasc Surg 1999;118:189. 96. Weiss RL, Brier JA, O'Connor W, et al: The usefulness of transesophageal
echocardiography in diagnosing cardiac contusions. Chest 1996;109:73. 97. Tousignant C: Transesophageal echocardiographic assessment in trauma and
critical care. Can J Surg 1999;42:171.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 13
98. Ibrahim AE, Stanwood PL, Freund PR: Pneumothorax and systemic air embolism
during positive-pressure ventilation. Anesthesiology 1999;90:1479. 99. Ho AM, Ling E: Systemic air embolism after lung trauma. Anesthesiology
1999;90:564. 100. Cheung AT, Savino JS, Weiss SJ: Beat-to-beat augmentation of left ventricular
function by intraaortic counterpulsation. Anesthesiology 1996;84:545. 101. Reichert CL, Koolen JJ, Visser CA: Transesophageal echocardiographic
evaluation of left ventricular function during intraaortic balloon pump counterpulsation. J Am Soc Echocardiogr 1993;6:490. 102. Shanewise JS, Sadel SM: Intraoperative transesophageal echocardiography to
assist the insertion and positioning of the intraaortic balloon pump. Anesth Analg 1994;79:577. 103. Scalia GM, McCarthy PM, Savage RM, et al: Clinical utility of echocardiography
in the management of implantable ventricular assist devices. J Am Soc Echocardiogr 2000;13:754. 104. Siegel LC, St. Goar FG, Stevens JH, et al: Monitoring considerations for port-
access cardiac surgery. Circulation 1997;96:562. 105. Coddens J, Deloof T, Hendrickx J, et al: Transesophageal echocardiography for
port-access surgery. J Cardiothorac Vasc Anesth 1999;13:614. 106. Secknus MA, Asher CR, Scalia GM, et al: Intraoperative transesophageal
echocardiography in minimally invasive cardiac valve surgery. J Am Soc Echocardiogr 1999;12:231. 107. Michel-Cherqui M, Brusset A, Liu N, et al: Intraoperative transesophageal
echocardiographic assessment of vascular anastomoses in lung transplantation. A report on 18 cases. Chest 1997;111:1229. 108. Huang YC, Cheng YJ, Lin YH, et al: Graft failure caused by pulmonary venous
obstruction diagnosed by intraoperative transesophageal echocardiography during lung transplantation. Anesth Analg 2000;91:558. 109. Branche PE, Duperret SL, Sagnard PE, et al: Left ventricular loading
modifications induced by pneumoperitoneum: A time course echocardiographic study. Anesth Analg 1998;86:482.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 13
110. Harris SN, Ballantyne GH, Luther MA, et al: Alterations of cardiovascular
performance during laparoscopic colectomy: A combined hemodynamic and echocardiographic analysis. Anesth Analg 1996;83:482. 111. Fahy BG, Hasnain JU, Flowers JL, et al: Transesophageal echocardiographic
detection of gas embolism and cardiac valvular dysfunction during laparoscopic nephrectomy. Anesth Analg 1999;88:500. 112. Fleisher LA, Mantha S, Roizen MF: Medical technology assessment: An
overview. Anesth Analg 1998;87:1271. 113. Connors AF Jr, Speroff T, Dawson NV, et al: The effectiveness of right heart
catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 1996;276:889. 114. Robin ED: Death by pulmonary artery flow-directed catheter: Time for a
moratorium? Chest 1987;92:727. 115. London MJ, Shroyer AL, Grover FL, et al: Evaluating anesthesia health care
delivery for cardiac surgery: The role of process and structure variables. Med Care 1995;33(10 suppl):OS66. 116. Kato M, Nakashima Y, Levine J, et al: Does transesophageal echocardiography
improve postoperative outcome in patients undergoing coronary artery bypass surgery? J Cardiothorac Vasc Anesth 1993;7:285. 117. Bergquist BD, Leung JM, Bellows WH: Transesophageal echocardiography in
myocardial revascularization: I. Accuracy of intraoperative real-time interpretation. Anesth Analg 1996;82:1132. 118. Bergquist BD, Bellows WH, Leung JM: Transesophageal echocardiography in
myocardial revascularization: II. Influence on intraoperative decision making. Anesth Analg 1996;82:1139. 45
119. Higgins TL, Estafanous FG, Loop FD, et al: Stratification of morbidity and
mortality outcome by preoperative risk factors in coronary artery bypass patients: A clinical severity score. JAMA 1992;267:2344. 120. Sutton DC, Kluger R: Intraoperative transoesophageal echocardiography: Impact
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 13
on adult cardiac surgery. Anaesth Intensive Care 1998;26:287. 121. Kolev N, Brase R, Swanevelder J, et al: The influence of transoesophageal
echocardiography on intra-operative decision making: A European multicentre study. European Perioperative TOE Research Group. Anaesthesia 1998;53:767. 122. Couture P, Denault AY, McKenty S, et al: Impact of routine use of intraoperative
transesophageal echocardiography during cardiac surgery. Can J Anaesth 2000;47:20. 123. Mishra M, Chauhan R, Sharma KKHP, et al: Real-time intraoperative
transesophageal echocardiography: How useful? Experience of 5,016 cases. J Cardiothorac Vasc Anesth 1998;12:625. 124. Suriani RJ, Neustein S, Shore-Lesserson L, et al: Intraoperative transesophageal
echocardiography during noncardiac surgery. J Cardiothorac Vasc Anesth 1998;12:274. 125. Pocock SJ, Elbourne DR: Randomized trials or observational tribulations?
[editorial; comment]. N Engl J Med 2000;342:1907. 126. Siwik ES, Spector ML, Patel CR, et al: Costs and cost-effectiveness of routine
transesophageal echocardiography in congenital heart surgery. Am Heart J 1999;138(4 Pt 1):771. 127. Seto TB, Taira DA, Tsevat J, et al: Cost-effectiveness of transesophageal
echocardiographic-guided cardioversion: A decision analytic model for patients admitted to the hospital with atrial fibrillation. J Am Coll Cardiol 1997;29:122. 128. Rosen AB, Fowler VG Jr, Corey GR, et al: Cost-effectiveness of transesophageal
echocardiography to determine the duration of therapy for intravascular catheterassociated Staphylococcus aureus bacteremia. Ann Intern Med 1999;130:810. 129. Weinger MB, Herndon OW, Gaba DM: The effect of electronic record keeping
and transesophageal echocardiography on task distribution, workload, and vigilance during cardiac anesthesia. Anesthesiology 1997;87:144. 130. Benson K, Hartz AJ: A comparison of observational studies and randomized,
controlled trials [see comments]. N Engl J Med 2000;342:1878. 131. Concato J, Shah N, Horwitz RI: Randomized, controlled trials, observational
studies, and the hierarchy of research designs. N Engl J Med 2000;342:1887. 132. Rafferty T, LaMantia KR, Davis E, et al: Quality assurance for intraoperative
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
46
Chapter 3 - Aortic Dissection and Trauma Value and Limitations of Echocardiography Elizabeth W. Ryan MD Ann F. Bolger MD
The rate of mortality with acute aortic dissection escalates hourly, [1] reaching 50% by 48 hours. Immediate diagnosis and therapy are critical for survival. Two thousand new cases of acute dissection are reported in the United States per year[2] the true incidence, including the large numbers of patients who die from unrecognized dissection, has been estimated at more that 10,000 per year.[3] Further, 10% to 30% of acute dissections occurring in the hospital may be misdiagnosed. Prompt diagnosis is a clinical challenge because patient's presenting symptoms may be nonspecific or even misleading. Aortic dissection must be included in the differential diagnosis of chest pain in many patients at risk for dissection and also when simultaneous acute involvement of multiple organ systems does not have a ready explanation. Acute dissection of the aorta can share many of the features of acute myocardial infarction: pain (related to the dissection itself or to myocardial ischemia), electrocardiographic abnormalities consistent with ischemia (resulting from involvement of the coronary ostia in proximal dissection),[4] and elevated serum creatinine kinase levels.[5] True myocardial ischemia is a potential component of the syndrome of aortic dissection. On pathologic examination, Hirst et al[6] found
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
involvement of the coronary arteries in 39 of 505 cases of acute dissection (7.7%). Confusion of acute dissection with myocardial infarction not only delays appropriate treatment but also may lead to disastrous consequences if thrombolytic agents are administered.[7] [8] Thrombolysis impedes compensatory thrombosis of the false channel and promotes uncontrollable hemorrhage in the event of aortic rupture. Given that the incidence of aortic dissection is far less than that of myocardial infarction (0.26% of 5011 patients in the Anglo-Scandinavian Study of Early Thrombolysis trial[7] ) and that ST segment elevation is a relatively rare finding in patients with aortic dissection, classic electrocardiographic changes without physical findings suggesting dissection will rarely mislead clinicians toward thrombolysis.[9] Maintenance of a high suspicion for dissection must be paired with highly reliable tests to avoid such infrequent but catastrophic misdiagnoses. The optimal diagnostic test for acute aortic dissection, therefore, must be accurate, safe, and immediately applicable in a broad range of medical environments. The limited sensitivity of echocardiography for dissection from the transthoracic approach has been greatly improved by transesophageal approaches; transesophageal examinations can be performed within minutes in the emergency department, operating room, or intensive care unit and provides high-quality images of the thoracic aorta as well as of other cardiac and vascular structures at risk. The advantages and limitations of echocardiographic techniques 47
in the management of patients with aortic dissection have been carefully investigated at many centers, and, as a result, their strengths and weaknesses relative to other imaging techniques are being better defined. Ongoing advances in transesophageal probe technology and other ultrasonographic imaging methods are proceeding rapidly, with smaller transducers, multiple and variable imaging planes, and wider ranges of frequencies being made available. These improvements are solidifying the already well-established role of echocardiography in the diagnosis and follow-up of aortic dissection.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/22.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 8
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Pathophysiology of Aortic Dissection Anatomy and Histology The aortic wall consists of three layers: the intima, which is a single layer of vascular endothelium; the media, with concentric layers of smooth muscle cells, collagen, elastin, and extracellular matrix proteoglycans; and the peripheral adventitia, consisting of loose connective tissue that anchors the aorta in surrounding tissues. The vaso vasorum, which perfuses the aortic wall, is contained within the adventitia. Of the three layers of the aortic wall, the structure of the media dominates the wall's mechanical properties.[10] Medial smooth muscle directly influences wall stiffness by contraction. In addition, smooth muscle cells are the major source of the extracellular matrix components. These include the elastin fibers, which can be stretched to 300% of their resting length without rupturing[11] and are important contributors to the normal pulsatile behavior of the vessel. Elastin is less important to the overall strength of the aorta than collagen, however, which is both stiffer and much stronger than elastin. The components of the media vary from vessel to vessel and change with age. In the aortas of older patients, the elastin content decreases and the collagen content increases, resulting in increased vascular stiffness.[12] The mechanical properties of the vasculature are also almost always disturbed in cases of systemic hypertension.[13] Mechanical and Shear Stresses The aortic wall is subjected to mechanical stresses of several forms. Stress, which is expressed as force per unit area, may occur in radial, circumferential, or longitudinal directions.[14] The normal intima bears little of the aorta's stress load. It is exposed to shear stresses, however, which are forces applied parallel to the vessel wall as a result of the viscous effects of blood flow. The amount of these shear stresses varies with the distribution of velocity across the vessel lumen and with local vessel geometry.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 8
Circumferential stress predominantly affects the media. This type of stress (δ) increases with the radial pressure from the aortic lumen (P) and the aortic radius (r), and decreases with increasing wall thickness (h): δ = Pr/h The danger of aortic dilation can therefore be understood: in dilated, thinwalled aortas, the circumferential stresses may be increased many times above normal. In addition, the geometry of the dilating aorta changes progressively from the normal cylinder to an ellipsoidal or even spherical shape. This slowly increases the circumferential stress but quickly exacerbates longitudinal stress. Most atraumatic aortic tears are caused by longitudinal stress, which explains why they are generally transverse in orientation.[15] The ascending aorta experiences additional longitudinal stress owing to the motion of the aortic annulus. Finally, dilated or aneurysmal vessels demonstrate marked stiffness, in part because of loss of elastin.[16] Combined aortic dilation, wall thinning, and shape change sets the stage for intimal rupture and the initiation of dissection. Intimal or medial abnormalities of the aorta increase the resistance to both shear and circumferential stresses. Stress failures of both types may play a role in aortic dissection. Circumferential stress failure can occur when the stresses caused by intraluminal pressure are greatly magnified in the thin fibrous cap of an atheromatous lesion. If the lesion fractures and a small crack develops, the circumferential stress will cause it to extend through the wall.[10] Shear stress failure is due to inhomogeneity in the properties of the vessel wall. Even under normal conditions, mural stresses are greater on the inner than on the outer wall.[15] In the presence of atherosclerosis, incremental variations in the shear resistance between contiguous regions of diseased and normal wall occur. The progression of aortic dissection probably represents an example of shear failure, in which the interface between two such aortic segments with different stiffness leads to separation of medial and intimal layers: the two layers slide relative to one another, because the "glue" of the extracellular matrix cannot withstand the shear stress.[10] Once initiated, dissections behave like a two-ply tube. The intima and the internal elastic lamina of the media form the inner layer, and the outer layer consists of the external elastic lamina and the adventitia. A velocitydependent shear force will then further separate the two layers, creating a false lumen separated from the true lumen by the intima and internal elastic
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 8
lamina.[15] Experimentally, it has been demonstrated that the work per unit area of tissue required to propagate a tear in the aorta is small (15.9 ± 0.9 mJ cm2 ), and independent of the depth of the tear.[17] These concepts of shear and tensile failure are the basis for understanding why different patient populations are at increased risk for aortic dissection. Medial elastic tissue degeneration resulting from hereditary defects of the arterial wall creates the substrate for dissection in patients with Marfan's syndrome, Turner's syndrome,[18] Noonan's disease, Ehlers-Danlos syndrome, and osteogenesis imperfecta.[15] [19] In these patients, as well as in other groups, dilation of the aorta is an important source of tensile failure and a precursor to dissection. Both wall abnormalities (shear failure) and increased wall stress (tensile failure) caused by dilation are important in nonhereditary risk groups. Dissection occurring in hypertensive patients is generally based on 48
high blood pressure, moderate aortic dilation, and medial muscular degeneration predisposing the internal layer to tear.[15] The contribution of shear stress in those patients is infrequent and unpredictable. Atherosclerosis In atherosclerosis, both generalized and focal manifestations can predispose to dissection. True aortic aneurysms are caused by atherosclerotic degeneration of the media and progress to involve all three layers of the vessel wall and to gradual dilation. Increasing risk accompanies diameters exceeding 10 cm, rapid expansion, or symptoms. Formation of laminar thrombus within the aneurysm does not decrease the wall stress. The 1-year survival rate in patients with thoracic aortic aneurysms is less than 60%, and the 5-year survival rate is approximately 20%. False aneurysms are created by through-and-through disruption of the media, with the adventitia alone confining the extravasation.[20] The risk of rupture is even higher in this setting. A third type of atherosclerotic aortic abnormality is penetrating aortic ulceration.[21] [22] In this case, rupture of atherosclerotic plaque causes fissuring into the media and creation of an intramural hematoma, which may progress to rupture or pseudoaneurysm formation. Trauma
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 8
Trauma is another important cause of dissection. Dissection may occur in external, accidental trauma and be difficult to assess in the setting of major multisystem injuries. The region most prone to traumatic injury is the aortic isthmus, where relative tethering by the spinal arteries and ligamentum arteriosum resists abrupt deceleration more than the more mobile transverse arch.[23] Other vulnerable sites include the origin of the innominate artery, particularly with vertical forces from falls, and the ascending aorta above the sinus of Valsalva. [24] Traumatic injuries to the aorta may result in intimal tears, recognizable on transesophageal echocardiography (TEE) scans as mobile flaps. Thrombus may be seen protruding into the lumen; in other cases, intramural hematoma without apparent intimal discontinuity is seen. Although very minor lesions such as minimal hematomas may regress spontaneously, the prognosis of significant aortic trauma is grave. Without repair, there is a 30% rate of mortality within the first 24 hours. Within 1 week, the mortality rate is greater than 50%.[25] Prompt recognition is therefore critical to patient outcome. TEE has been shown to be safe and highly sensitive for aortic trauma after motor vehicle accidents, equivalent to angiography and more expeditiously applied.[26] TEE may also detect other signs of cardiac trauma, including wall motion abnormalities, pericardial effusion, and valvular insufficiency. When the suspicion of aortic rupture in the territory of the transverse arch remains high, computed tomography (CT) may provide better images of those territories. Other sources of trauma include the Heimlich maneuver for respiratory obstruction and cardiovascular procedures. Operative sources of tears in the aorta include cannulation sites for cardiopulmonary bypass, aortic transections for valve or aortic segment replacement, and proximal anastomotic sites for coronary bypass grafts.[27] [28] Very uncommonly, aortic catheterization for angiography may traumatize an atherosclerotic region and prompt dissection.[29] Angioplasty procedures of coronary or renal vessels can also initiate the process.[30] A history of these procedures may be important in alerting the clinician to the possibility of dissection in these patients. Pregnancy Although aortic dissection is mostly a disease of middle-aged or elderly men, women and children can also experience dissection. It has been claimed that half of all aortic dissections occurring in women younger than 40 years of age are associated with pregnancy, particularly during the third trimester or the postpartum period.[31] [32] [33] This finding has been disputed
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 8
by Oskoui and Lindsay,[34] who reviewed their own experience and published a series of 1253 dissections in consecutive patients (868 men and 385 women), with no cases occurring in pregnancy. They concluded that most women experiencing aortic dissection in pregnancy had other risk factors such as hypertension or Marfan's syndrome, and that the apparent association could result from selective reporting and coincidental occurrence of dissection with the very common condition of pregnancy. There are also other well-recognized causes of aortic dissection (Table 31) .[35] [36] [37] [38] [39] [40] [41] [42] [43] Genetic Diseases Of the genetic causes of aortic medial disease and aortic dissection, Marfan's syndrome is the most common and best studied. Although a clinical diagnosis, Marfan's syndrome can be confirmed by linkage to the dominantly inherited gene MFS-1 on 15q21 or by determination of the specific family mutation.[44] Histologic examination of the aortic wall in patients with Marfan's syndrome reveals fragmentation of aortic components, especially the elastic fibers,[45] and abnormal accumulation of collagenous and mucoid materials in the media.[46] Fragmentation of elastinassociated microfibrils also occurs in aortic valve leaflets. [47] The disruption and loss of elastic tissue of the media is attributed to a deficiency of fibrillin, a microfibrillar protein that scaffolds the elastic lamellae in the aortic wall.[48] [49] These changes are greatest in the ascending aorta, which is subject to the greatest pulsatile expansion and therefore the highest stress in systole.[15] The alterations in aortic wall components are associated with abnormal functional properties: aortic elasticity is abnormal in patients with Marfan's syndrome, irrespective of the aortic diameter. [50] A comparative study of aortic wall dynamics between patients with Marfan's syndrome and normal control subjects confirmed that, in both groups, stiffness of the wall increases with age and aortic diameter, but at all ages the patients in the Marfan's syndrome group exhibit a stiffer aorta for a given diameter than the control subjects do.[51] Furthermore, Marfan's syndrome patients have large ascending aortic diameters, but not 49
TABLE 3-1 -- Patient Populations at Risk for Aortic Dissection Genetic disorders (medial abnormalities)
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 8
Marfan's syndrome Turner's syndrome Noonan's disease Ehlers-Danlos syndrome Osteogenesis imperfecta Congenital disorders Aortic coarctation Unicuspid or bicuspid aortic valve Degenerative disorders Hypertension Atherosclerotic vascular disease Aortic ulcer Aortic aneurysm Non-Marfan's syndrome cystic medial necrosis Traumatic causes Deceleration injury Penetrating injury Heimlich maneuver Postprocedural causes Cardiac surgery Cannulation Cross-clamping Aortic valve replacement Angioplasty Coronary Renal Inflammatory disorders Syphilis Giant cell arteritis Other conditions
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 8
Pregnancy Weight lifting Cocaine use Discontinuation of beta blockers Polycystic kidney disease abdominal aortic size, after correction for body surface area.[50] Dissection occurs in Marfan's syndrome patients because of this dilation in combination with wall weakness; mural stress increases dramatically with increasing radius and becomes self-perpetuating[15] (Fig. 3-1) . Echocardiographic evidence of aortic root dilation is present in 60% to 80% of patients with Marfan's syndrome.[52] [53] In one series, aortic dilation was generalized in 51% and localized in 28% of patients.[54] Localized dilation did not appear to represent an earlier stage of aortic involvement, as the patient ages in both groups were identical, as was the duration of follow-up. It could not be determined whether generalized dilation reflected more severe underlying cystic medial necrosis from different specific mutations in fibrillin. Generalized dilation, however, was associated with higher rates of expansion as well as aortic regurgitation. In Marfan's syndrome patients, aortic insufficiency has been associated with decreased survival.[43] The existence of mitral valve prolapse does not appear to be an independent predictor of outcome. The clinical course of patients with Marfan's syndrome with respect to progressive aortic dilation and dissection is variable[55] increased risk has been associated with older age,[54] [55] male gender, aortic root diameters exceeding 60 mm,[56] aortic growth rate,[54] [55] and a family history of dissection.[57] Of great concern is the observation that aortic dissection can occur in Marfan's syndrome patients even in the absence of aortic root dilation.[58] Medical management of Marfan's syndrome patients with aortic dilatation involves beta blockers and observation of aortic root diameter to determine the timing of elective surgery aimed at preventing aortic dissection. Longterm fatality rates are improved with prophylactic aortic root replacement; the 5-year survival rate approximates 97% for elective surgery versus only 51% with emergency surgery for dissection.[59] Operative mortality in experienced centers for elective surgery in Marfan's syndrome patients is low (1.3% to 1.5% 30-day mortality rate versus 11.7% for emergency surgery).[60] [61] In patients with normal aortic valve leaflets, elective aortic valve-sparing surgery may provide better clinical outcomes than aortic root
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 8
replacement,[62] although in this retrospective review, patients undergoing aortic root replacement with aortic valve replacement had more cardiac comorbidities than the patients in whom valve-sparing surgery was possible. The size of aneurysm often determines the feasibility of valvesparing surgery; therefore, some centers recommend elective surgery when the aortic root reaches 50 mm.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/23.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 3
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Spectrum of Aortic Dissection The primary entry tear that initiates aortic dissection is usually transverse and involves more than half of the circumference of the aorta. In 65% of cases, it occurs within 3 cm of the coronary ostia. Ten percent of tears occur in the descending thoracic aorta and another 10% in the arch. Primary tears are rare in the abdominal aorta.[63] Whatever the location of the initial tear, dissections may extend caudally, proximally, or occasionally in both directions. Figure 3-1 Type A aortic dissection (arrows indicate intimal flap) in a patient with Marfan's syndrome. Prolapse of the posterior mitral valve leaflet is also noted.
Anatomic Classification
50
There are several widely used classification systems for dissection (Table 3-2) . The DeBakey classification divides dissections with involvement of the ascending aorta into type I, which extends into the transverse arch and distal aorta, type II, which is confined to the ascending aorta, and type III, which involves the descending aorta only.[64] The Stanford classification[65] was developed from a functional approach based on whether the ascending aorta is involved, regardless of the site of primary intimal tear and irrespective of the extent of distal propagation. This reflects clinical observations that the biologic behavior of the dissection, the clinical prognosis, and how the patient should be managed pivot almost exclusively on whether the ascending aorta is involved.[66] [67] [68] This system of nomenclature describes type A dissections as any with involvement of the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 3
ascending aorta (including DeBakey types I and II), and type B dissections as dissection limited to the descending aorta (DeBakey type III). The clinical classification schemes described do not emphasize the location of the primary entry tear or the extent of the distal propagation of the dissection. These two factors are of less prognostic value and can be technically difficult to determine.[69] [70] When identification of the entry site is possible, the culprit primary intimal tear is more easily resected. Although successful resection of the primary tear does not appear to affect early or late survival rates, it may decrease the incidence of late reoperation.[71] Some cases of aortic dissection will present with multiple "primary" tears. Two separate dissections in the same patient may be more common than previously reported. Roberts and Roberts[72] reported that 3 of 40 necropsy patients had separate proximal and distal thoracic dissections. Although all fatal events were caused by rupture of the acute proximal dissections, a separate distal dissection may still pose a risk for late complications, and therefore recognizing two separate dissections may have important implications in terms of follow-up and therapy.[73] Multiple distal "exit" tears, which decompress the false lumen, are extremely common. Time Course Dissections are also differentiated with respect to their time course. Acute dissections are detected within 14 days of the onset of initial symptoms. Chronic dissections TABLE 3-2 -- Nomenclature of Aortic Dissection Dissection Type Ascending aorta involved
Ascending aorta not involved
Classification Stanford type A DeBakey I DeBakey II University of Alabama "ascending"[56] Massachusetts General Hospital "proximal"[57] Stanford type B DeBakey III University of Alabama "descending"[56] Massachusetts General Hospital "distal"[57]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 3
present more than 2 weeks after onset.[68] [74] This division is arbitrary; it may primarily reflect the fact that the majority of type A dissection patients will die within 2 weeks if untreated.[75] Chronic dissections may be detected because of symptoms or may be an incidental finding. They are differentiated from aortic aneurysms by the presence of an intimal flap and false lumen. These may not be easy to recognize when the false lumen is largely thrombosed. Pronounced atherosclerotic changes may be present in the false lumen in chronic dissections, even when the true lumen walls appear normal and hyperlipidemia is absent.[76] Sequelae The concomitant sequelae of aortic dissection are many and varied. Obstruction of branch vessels may explain acute myocardial ischemia and infarction of cerebral, spinal, bowel, and renal territories. Aortic valve dehiscence with regurgitation, cardiac tamponade from retrograde extension into the pericardium, and frank aortic rupture are all highly morbid consequences.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/24.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 9
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Echocardiography in Aortic Dissection Time is of the essence when aortic dissection is suspected, and the entire thoracic aorta must be visualized. Transthoracic echocardiography is immediately available, and, in some cases of proximal dissection, it may visualize the ascending aortic intimal flap and false lumen, or a flap in the descending aorta may be visible from the suprasternal (Fig. 3-2) or subcostal windows. Other clues to dissection available from transthoracic approaches include pericardial effusion with or without tamponade, aortic valve insufficiency with or without leaflet dehiscence, aortic root dilation, or regional wall motion abnormalities. Given the variable occurrence of any of these abnormalities, it is not surprising that the sensitivity of transthoracic echocardiography has been limited (Table 3-3) . Transesophageal Imaging Transesophageal echocardiography has elevated ultrasonic diagnosis of dissection into the first line of clinical options (Fig. 3-3) . Multiple studies have documented specificity and sensitivity in the range of 98% and 99%, respectively. The recognized blind spot of TEE, involving the distal ascending aorta and superior aspect of the arch, is an important limitation, especially because entry tears in this region are important to clinical management. The goal of imaging the entire thoracic aorta may therefore require a combination of modalities and approaches, including transthoracic views (often from the suprasternal notch), transesophageal windows, and often direct epiaortic or epicardial views at the time of surgery. Transesophageal echocardiography has many discrete advantages in the diagnosis of acute aortic dissection, the most important of which is its documented accuracy. Erbel 51
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 9
Figure 3-2 Suprasternal views of the transverse and descending aorta demonstrate the intimal flap (A, arrows) as well as an entry tear with systolic flow from the true lumen into the false lumen (B) (color plate).
et al,[77] reporting for the European Cooperative Study Group for Echocardiography on a series of 164 patients suspected of acute dissection, demonstrated sensitivity and specificity rates of 99% and 98%, respectively. Another large study by Nienaber et al[78] compared TEE with magnetic resonance imaging (MRI). Both TEE and MRI had perfect sensitivity; the 100% specificity of MRI exceeded the 68% specificity of TEE. The authors suggested that TEE's limited visualization of common ascending aorta pathologic lesions might have accounted for the higher rate of false-positive findings. In that study, strict criteria for diagnosing dissection were not applied (see later discussion); more stringent criteria could minimize false-positive results. Transthoracic echocardiography TABLE 3-3 -- Imaging Modalities for Aortic Dissection
Study Appelbaum et al[67] Miller[66] Daily et al
Modality TTE
Positive Negative Sensitivity, Specificity, Predictive Predictive A % % Value, % Value, % 77 93 — —
TTE TTE
59 83
83 63
— 80
— 70
Miller[66] TEE Chirillo et TEE al[1] Daily et al TEE
98 98
77 97
— 98
— 97
100
68
82
100
88
94
96
84
88
97
97
85
100
100
100
100
98
98
—
—
[65]
[65]
DeBakey Aortography et al[64] Chirillo et Aortography al[1] Daily et al MRI [65]
Miller[66]
MRI
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Silvey et al CT
Pagina 3 di 9
83
100
100
86
94
87
—
—
[83]
Erbel et al CT [94]
CT, computed tomography; MRI, magnetic resonance imaging; TE transesophageal echocardiography; TTE, transthoracic echocardiograp from the suprasternal notch provides additional views of this vulnerable area. The sequential use of TEE and CT, aortography, or MRI is clearly extremely powerful in clarifying suspicious or clinically incongruous results.[79] [80] Transesophageal echocardiography provides additional information about left and right ventricular wall motion and global function and aortic and mitral valve competence. Importantly, with acute type A dissections, TEE is able to detect and determine the severity and mechanism of aortic valve regurgitation[81] and may influence the decision to replace or repair the valve. An important advantage of TEE in cases of dissection is its rapid and safe performance in a wide range of clinical environments, including emergency departments, 52
Figure 3-3 Examining the aorta in multiple planes is essential. In this case, the short-axis view (A) suggests an abscess cavity. The long-axis view (B), however, demonstrates a longitudinal dissection flap (arrows). Ao, aorta; LA, left atrium.
intensive care units, and the operating room. TEE requires minimal patient preparation, avoids the contrast agent and x-ray exposure associated with CT and angiography, and eliminates the time delays and practical encumbrances of MRI. Choice of a "best test" must always take into account the individual center's track record with each modality, as well as access issues. Safety of Transesophageal Echocardiography The safety of transesophageal examinations depends on adequate patient
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 9
preparation with respect to pain, anxiety, and airway protection. Careful monitoring of the electrocardiogram and blood pressure is critical to avoiding adverse affects of TEE. In a study of 54 ambulatory patients, TEE was accompanied by an increase in systolic pressure in 77% of patients. This elevation was moderate (average increase of 16 mm Hg) in most patients, but some patients had acute increases of as much as 51 mm Hg.[82] Abrupt increases of blood pressure must clearly be avoided in any patient suspected of having a dissection. Serial blood pressure monitoring, pulse oximetry, intravenous sedation, topical anesthesia, and control of blood pressure with intravenous vasodilators and beta blockers, if needed, are important to patient safety. With these precautions, the majority of patients can undergo esophageal intubation with minimal distress and good hemodynamic stability. Even so, there has been a reported case of aortic rupture occurring during TEE in a patient with an acute dissection, which might have been elicited by retching and elevated blood pressure.[83] Other commonly reported adverse events during transesophageal studies that must be anticipated and avoided are nonsustained atrial and ventricular arrhythmias, excessive vagotonia with transient atrioventricular block, and arterial hypoxemia.[84] Diagnostic Features The diagnosis of aortic dissection is most secure when very specific criteria are met. Identification of an intimal flap, seen as a mobile, linear echo within the vascular lumen, and flow in the true and false channels on either side of the flap are highly sensitive features of dissection. The motion of the intimal flap toward the false lumen during systole may be a helpful feature. A thickening of the aortic wall in excess of 15 mm has also been used as a sign of dissection, suggesting thrombosis of a false channel, which makes the intimal flap difficult to recognize.[85] Strict adherence to these criteria can avoid confusion with imaging artifacts and manifestations of other types of disease and minimize false-positive results.[86] This is particularly important because most patients suspected of having an aortic dissection have evidence of vascular disease involving the thoracic aorta. In one series of 40 patients evaluated for dissection, abnormal aortic findings (including atherosclerotic plaques, intravascular and extravascular masses, thrombi, and dilation) were found in 16 of 17 patients in whom aortic dissection and coronary artery disease were excluded as explanations for their chest pain.[87] Other underlying aortic abnormalities such as coarctation or prior surgical repair may affect clinical management, but they are also important potential sources of misdiagnosis.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 9
Doppler Findings Color Doppler flow imaging during TEE is an excellent descriptor of aortic flow patterns with acute dissection. Flow in the false channel is variable and complicated; the true lumen, which is often dwarfed by the false channel, is identified by forward systolic flow (Fig. 3-4) . With large proximal entry tears, flow in the nearby segments of the false lumen may have the same direction and timing as the true lumen flow and may reverse in diastole.[88] [89] With 53
Figure 3-4 A short-axis transesophageal echocardiographic view of the descending aorta shows a small anterior true lumen and a larger posterior false lumen that is partially thrombosed (left, arrow). A pulsed Doppler signal from the true lumen, oriented from a long-axis view (right), demonstrates forward systolic flow.
smaller or more distal tears, false lumen flow is less similar to true lumen flow: it may be directed in the opposite direction, and peak velocity may occur later in the cardiac cycle, representing delay of flow into the false lumen. Many areas will show extremely slow, swirling flow with spontaneous echo contrast or partial thrombosis (Fig. 3-5) . These segments tend to be remote from large entry or exit sites, where high-velocity flow keeps these changes from occurring. Finally, areas of complete thrombosis are also seen, and care must be taken to ascertain that the hematoma is entirely intravascular and not actually Figure 3-5 Transesophageal echocardiogram of the descending thoracic aorta demonstrates the true lumen anteriorly and a thrombosing false lumen posteriorly in a patient with acute aortic dissection. As the false lumen thrombosis proceeds, the only clue to dissection may be the apparent "thickening" of the aortic wall.
the result of adventitial rupture, pseudoaneurysm formation, or intramural hematoma (Fig. 3-6) . Multiple communications between the true and false lumens are often identified on careful scanning of the entire thoracic aorta. Some will represent entry sites with flow from the true toward the false channel, and others will be exit sites or have bidirectional flow (Fig. 3-7) . Exit tears,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 9
where flow re-enters the true lumen from the false lumen, may occur at one or multiple sites. The exact location of a given tear can be estimated from the depth of probe insertion from the incisors, an arbitrary but 54
Figure 3-6 Transesophageal view of the descending aorta at 40 cm from the incisors in a patient with a prior proximal dissection and repair. There is discontinuity of the posterior aortic wall and a large thrombus extending into the periaortic tissues. This was confirmed to be a descending thoracic aortic rupture on subsequent surgery.
convenient reference point. Recording this information at the time of the procedure and on the written report not only is helpful in the surgical correction of dissection, but also is extremely important for comparison with postoperative follow-up TEE studies, in which many of the original tears may still be detectable. Identification of the primary entry site must be deduced from location, size, and flow patterns. In some cases, the primary tear cannot clearly be assigned to any one tear, either because of multiple tears as described Figure 3-7 A short-axis transesophageal echocardiographic view of the descending aorta with a large entry tear in the intimal flap. Pulsed Doppler echocardiography demonstrates flow from true to false lumen during systole. FL, false lumen; TL, true lumen.
earlier or, in some cases, because of the TEE blind spot. Adachi et al[90] were able to identify the entry site in 50 of 57 patients with acute dissection. They were more successful in this with type B dissections (90%) than with type A (83%). As mentioned previously, identification of the primary tear is mostly important because ensuring that the surgical repair resects the primary entry site may decrease the incidence of late reoperation. Complications of Dissection An important goal of echocardiographic imaging in aortic dissection is identifying associated complications. Type A dissections may produce acute aortic insufficiency because of annular dilation or disruption of leaflet suspension. TEE can provide detailed morphologic information regarding
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 9
the quality of the leaflet tissue and the mechanism of aortic insufficiency; these can help in the decision regarding valve resuspension versus replacement. Pericardial effusion and tamponade are manifestations of aortic rupture with dissection and are often readily identified on transthoracic views. The Doppler manifestations of pericardial tamponade may be best obtained from external apical views and may obviate preoperative TEE in the interest of moving the patient emergently to the operating room. Small effusions unassociated with tamponade physiology may not be related to rupture and can be evaluated with contrast echocardiography if time and patient stability allow (Fig. 3-8) . Other rupture syndromes can occur at different sites. Uncontained rupture into the mediastinum or pleural space causes sudden death. Some ruptures are contained by the aortic adventitia, resulting in pseudoaneurysm formation or hematoma. In these cases, TEE can detect the intimal breach as well as the extension of the hematoma into the surrounding tissues; contrast can be helpful in delineating protuberant thrombus and rupture (Fig. 3-9) . An important proviso is to image the aorta at an adequate imaging depth so that such a hematoma 55
Figure 3-8 A four-chamber transesophageal echocardiographic view during contrast injection (Optison) shows contrast in the left ventricular cavity but not in the small pericardial effusion (arrow), which was unassociated with tamponade physiology.
can be recognized. These extravasations can be missed if the imaging field is restricted to the expected aortic contours; disastrous consequences can ensue if the site of the extravasation is not corrected along with the proximal aortic repair. Intramural Hematoma A small number of aortic dissections, estimated at 3% to 5%, occur without apparent intimal disruption.[6] [91] The pathologic process in these cases is rupture of the vasa vasorum into a region of medial degeneration, or possibly rupture of atherosclerotic plaque. Patients with this form of disease tend to be older (mean age, 70 years versus 56 years for communicating dissection) and have frequently had long-term hypertension. Transesophageal images
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 9
Figure 3-9 A transesophageal echocardiographic view of the ascending aorta suggests an intimal flap with possible lumen rupture. Contrast injection (A, Optison) does not confirm extravasation outside the aorta (B, arrow).
demonstrate a thickened aortic wall with intramural echo-free spaces, an increased distance from the TEE probe to the inner aortic wall, and focal distortion of the transverse circular configuration of the aorta. This process has been described on CT images as well, seen as circular high-intensity areas along the aortic wall. [92] In their series, Mohr-Kahaly et al[93] described this type of noncommunicating aortic dissection as a dissection membrane without intimal tear and often involving the entire descending thoracic aorta. Early prognosis in those patients was somewhat better than in those with acute "communicating" dissections; this may reflect the tendency for the noncommunicating medial space to heal with complete thrombus formation.[94] These intramural hematomas may progress to typical dissection (in 33%) or to rupture (in 27%) and therefore usually require surgical rather than medical management.[95] Coronary Artery Involvement Involvement of coronary arteries by aortic dissection is an important issue, and one that raises the question of whether preoperative coronary angiography is mandatory. Involvement of one or both coronary arteries by acute aortic dissection has been estimated to occur in 10% to 20% of cases. [96] In a series of 34 aortic dissection patients, Ballal et al[97] detected coronary involvement with TEE in six of seven surgically documented dissected coronary arteries. Of note, electrocardiographic changes were demonstrated in only two of the six patients with coronary involvement. Adequate views of the ostia and proximal vessel were obtained for 88% of left main arteries and 50% of right coronary arteries overall. Visualization of the ostia and proximal coronary arteries continues to improve as variable imaging plane TEE probes are utilized and higher frequencies become available (Fig. 3-10) . A separate but related issue is whether concomitant coronary artery disease, independent of coronary dissection, is an important consideration that should prompt routine angiography. Given the underlying vascular disease 56
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 9
Figure 3-10 A short-axis transesophageal echocardiographic view of the aortic root demonstrates an intimal flap in proximity to the left coronary ostium. LC, left coronary.
that affects many patients with dissection, it is not surprising that coronary disease has been found in up to 43% of patients with aortic dissection. The benefits of addressing potentially important coronary stenoses must be weighed against the risk of delays and aortic manipulation during acute dissection and adjusted for the patient's baseline likelihood of coronary disease. A series of 122 patients from the Cleveland Clinic found no difference in the in-hospital mortality rate between patients who had emergency coronary arteriography before dissection repair and those who did not. Three fourths of all coronary artery bypass procedures performed in that series were done because of coronary dissection rather than obstruction owing to coronary artery disease.[98]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/25.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 5
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Surgical Considerations The planning of surgical correction of aortic dissection is heavily influenced by many of the features discussed earlier. The extent of the dissection, the location of primary tears, and concomitant valvular insufficiency and coronary disease are all critically important to the surgical team. In addition, safe cannulation sites, aortic valve repair strategies, need for coronary reimplantation with root replacement, and confirmation of adequate cardiopulmonary bypass and even intra-aortic balloon function can all be addressed with intraoperative ultrasonography (Table 3-4) . Transesophageal imaging during surgery has the advantage of being nonobtrusive (at least for the surgeon, if not for the anesthesiologist) and is commonly also used as an accurate monitor of left ventricular wall motion and volume status. Intraoperative Echocardiographic Monitoring An additional tool for completing the scan of the aorta is intraoperative imaging from the epicardium or surface of the aorta. The unlimited number of acoustic windows from this approach allows careful interrogation of the aortic root, origins of the great vessels, cardiac valves, and left ventricular wall motion. The transesophageal blind spots in the ascending aorta and transverse arch can be thoroughly inspected from the epicardium, and potential aortic cannulation sites can be evaluated from the exterior aortic surface (Fig. 3-11) . Epicardial views give much greater freedom of visualization and measurement of the aortic valve and allow precise annular sizing before cardiopulmonary bypass to expedite selection of the valvular prosthesis. The position of the coronary ostia relative to the dissection and the annulus can be defined precisely with epicardial views, which may also aid in surgical decisions regarding valve-graft conduit placement or coronary ostial reimplantation. The amount of time required for imaging in the surgical field can be limited
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 5
to a few minutes, but this achievement requires an experienced team with a surgeon or cardiologist familiar with the epicardial techniques and TABLE 3-4 -- Operative Uses of Transesophageal Echocardiography in Aortic Dissection Site Feature Pre–Cardiopulmonary Bypass Assessment Aorta Intimal flap Entry tear * Intramural hematoma Aortic rupture Aortic pseudoaneurysm Distal extent of extension Additional tears False lumen flow patterns, including thrombus Branch vessel involvement * Coronary situs and dissection Involvement of origins of great vessels Underlying pathologic condition Atheromatous disease Coarctation Sites of previous repairs Cannulation and cross-clamp sites Aortic valve Insufficiency Suitability for repair vs. replacement Sizing for allograft replacement Mitral valve Insufficiency Suitability for repair vs. replacement Left and right ventricle Wall motion abnormalities Pericardium Effusion Post–Cardiopulmonary Bypass Assessment Aorta Confirm competency of proximal anastomosis
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 5
Establish baseline for false lumen flow and distal tears Aortic valve Confirm competency of repaired valve Mitral valve Confirm competency Left and right ventricle Wall motion Intra-aortic balloon Confirm position in true lumen * Epicardial and/or epiaortic scanning may be important in fully defining these features.
57
Figure 3-11 Intraoperative epiaortic view of the transverse aortic arch in a patient with acute proximal aortic dissection. The intima is widely dissected and highly mobile. Note the linear streaking artifact from electrocautery.
views. The combination of epicardial and transesophageal techniques ensures that a high-quality ultrasonographic image is acquired of all segments of the aorta above the diaphragm and eliminates any uncertainty regarding involvement of the ascending aorta. Post-cardiopulmonary bypass images from the epicardium can also be extremely helpful in reassessing proximal tears and interrogating suture lines between aorta and conduit. Transesophageal views at the conclusion of cardiac surgery confirm aortic valve or prosthetic valve competency and allow prompt reinstitution of support if significant aortic insufficiency demands surgical revision. Intraaortic balloon pump position can be assessed with TEE (Fig. 3-12) ; accidental placement of the balloon in the false lumen can be disastrous if not immediately recognized.[99] Finally, postoperative TEE images of the graft and native aorta create a baseline for subsequent follow-up studies. Choice of Surgical Procedure The goal of surgical correction of aortic dissection is to prevent the most common causes of death. For type A dissections, death is caused by
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 5
intrapericardial rupture and tamponade in 80% to 90% of cases and by extrapericardial rupture in 5% to 10%. For type B dissection, rupture causes 60% to 70% of deaths. A localized and conservative operative procedure prevents most deaths and is associated with the lowest number of operative risks. This generally consists of resection of a limited segment of aorta containing the worst damage, including the primary intimal tear if possible, and reconstruction of the local pathologic lesion. If required, however, extensive aortic reconstruction for dissection has been reported with longterm survival rates of 88.5% at 1 year and 81.7% at 9 years in a small series of Marfan's syndrome patients.[100] Coexisting Aortic Insufficiency Aortic valve insufficiency complicating aortic dissection has negative effects on outcome and may dictate important issues in the surgical approach. Preservation of the native aortic valve is possible in 86% of type A dissections with excellent results.[101] If the aortic annulus is abnormal because of Marfan's syndrome or annuloaortic ectasia, aortic valve replacement is preferred because of the limited long-term durability of aortic valve reconstruction in these patients. Initiation of cardioplegia for cardiopulmonary bypass usually depends on a competent aortic valve to allow antegrade perfusion of the coronary arteries; in the presence of significant aortic insufficiency, therefore, individual ostial cannulation or coronary sinus retroperfusion may be indicated. The specific causes of aortic insufficiency are also important[81] normal-appearing leaflets with a prolapsing cusp caused by avulsion of the leaflet base may be amenable to aortic repair with resuspension. Other cases may require aortic valve replacement. The specific involvement of the adjacent aortic root is also critical and may require a variable extent of prosthetic conduit. In some cases, human aortic allografts are used, which have the advantage of supplying both natural aortic valve and root. In proximal aortic involvement, the position and involvement of the coronary ostia are important. Ostial reimplantation may be necessary; coronary bypass grafting may be unavoidable if the coronary arteries are dissected. Coronary arteries may be reattached by direct reimplantation with or without a surrounding button of aortic tissue, reattached to a piece of prosthetic conduit (the Cabrol procedure), or completely bypassed with saphenous vein or internal mammary artery grafts. Figure 3-12 The position of the intra-aortic balloon pump (bright echo,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 5
upper right) can be confirmed with transesophageal echocardiography. This balloon is placed correctly in the anterior true lumen.
Coexisting Mitral Regurgitation
58
Mitral regurgitation is a different example of a valvular abnormality associated with aortic dissection. New insufficiency may result from wall motion abnormalities induced by coronary involvement in the dissection, or from acute left ventricular dilation induced by aortic insufficiency. In other cases, mitral regurgitation is part of the underlying disorder, as is the case with Marfan's syndrome with mitral valve prolapse. Identification of the etiologic factors in the mitral insufficiency (e.g., leaflet degeneration, ventricular dilation, papillary muscle ischemia) will influence the need for repair or prosthetic replacement. Confirmation of results on early postcardiopulmonary bypass images is important, especially when the decision is made to leave the mitral valve alone despite some insufficiency in hopes that correction of acute ischemia or dilation will remedy it. Perfusion of Distal Vascular Beds In an acute aortic dissection, organs may be perfused by either the true or the false lumen flow. Organ under-perfusion may occur if flow to the source lumen is compromised. During surgery, malperfusion may be caused by flow reversal when cardiopulmonary bypass is established by cannulation of the femoral artery, with obliteration of major communications between the two lumens from cross-clamping, or with repair of the dissection itself. Neustein et al[102] describe a case in which femoral cardiopulmonary bypass compressed the true lumen and created severe malperfusion once the dissection was repaired. Perfusion through the new ascending aortic graft allowed immediate reinstitution of forward flow.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/26.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 3
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Follow-up of Patients after Repair of Aortic Dissection Persistent Intimal Flaps Despite successful surgical repair of aortic dissection, the aorta retains many abnormalities of structure and Figure 3-13 (color plate.) Distal tears are frequently present in aortic dissection. A, During systole, flow crosses from the true lumen into the false lumen. B, During diastole, flow reverses as the false lumen decompresses. C, Tears are usually multiple; here, two discrete tears with systolic flow into the false lumen are seen at the same level of the aorta. TRUE, true lumen; FALSE, false lumen; DESC AO, descending aorta.
flow. Distal to the repair, the intimal flap and false lumen persist. The false lumen may thrombose, or it may retain flow along with entry and exit flow through multiple fenestrations (Fig. 3-13) . One study detected persistent flap and false lumen in 100% of post-repair patients by MRI.[103] Persistent flow in the false lumen can be detected with TEE in the majority of patients after surgical repair. Mohr-Kahaly et al[89] found persistence of the false lumen in 71% of their postoperative patients at a follow-up interval of 1 to 41 months, and in 82% of their medically treated patients. Dinsmore and Willerson[104] have suggested that long-term survival is poorer in patients with persistent flow in the false lumen. Thrombosis of the false channel seems to be protective, a "natural buttress against future or further extension of the dissection." TEE confirms that sites without communications develop low-velocity flow and thrombus, whereas "healing" changes are less likely to occur in regions with significant tears and persistent flow. TEE also demonstrates aggressive atherosclerotic changes and calcification of the "neointima" lining the false channel. Progression of Disease
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 3
Patients with previous dissection may develop progressive abnormalities of both operated and nonoperated aortic segments. Twenty-five to 40% of original dissections will enlarge over time, and the rate and extent of enlargement are primary factors driving the need for reoperation.[96] In addition, dilation of noncontiguous, nonoperated aortic segments develops in 17% of patients with prior acute type A dissections. Early recognition of this progressive downstream aortic pathology allows reoperation in hopes of preventing rupture or redissection.[105] The concern regarding disease progression commits these patients to routine follow-up studies indefinitely. Pseudoaneurysm Formation Pseudoaneurysms form in 7% to 25% of patients with composite grafts, such as a Bentall procedure, secondary to hemorrhage at a suture line dehiscence. [106] Blood between 59
the graft and aortic wall can create supravalvular aortic stenosis.[107] Both of these complications can be detected and completely delineated by TEE,[108] as well as by CT, angiography, and MRI.[109] [110] Color flow Doppler will demonstrate blood flow into the echo-free space between the graft and the aortic wall. Other postoperative complications include endocarditis and the development of an aneurysm in the sinus of Valsalva.[111] Recurrent Disease Because the symptoms of acute redissection or expansion of a chronic dissection are nonspecific, the ability to reassess rapidly and compare the current findings with previous images is extremely important. Younger patients, those with Marfan's syndrome, and those with primary tears involving the transverse arch are particularly prone to progression of their disease.[112] Because TEE may not be able to reproducibly measure the true transverse diameter of an ectatic aorta, suspicion of chronic expansion usually requires additional confirmatory tests such as CT or MRI. Excellent definition of the intimal flap, false channel thrombi and flow patterns, and consistent reference landmarks for serial sizing over time make MRI a highly reliable method. When recurrent chest pain or hemodynamic instability suggests acute redissection, TEE can rapidly define the new pathologic abnormality and its extent. Changes from baseline postoperative or postdissection images can be extremely helpful in clarifying the etiologic
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Limitations of Transesophageal Echocardiography False-Negative Results The interposition of the trachea between the esophagus and the heart creates a blind spot that obscures portions of the distal ascending aorta, superior transverse arch, and origins of the great vessels. As a result, a dissection limited to these areas could be missed by transesophageal imaging alone. This is of concern because the clinical behavior and therapeutic approach to the patient depends largely on whether the proximal aorta is involved in the dissection. The occurrence of this extremely limited type of dissection must be very rare, because the incidence of false-negative studies has been minimal in large series.[76] In addition, large series have not confirmed a positive angiographic or CT result when the initial TEE result was negative. The involvement of the great vessels may not modify the surgical approach and can be assessed at operation.[113] The combination of transesophageal imaging with transthoracic imaging from suprasternal and parasternal windows yields a much more thorough assessment of the arch. CT, MRI, or angiography can also be used to assess this area when there is persistent clinical suspicion of a dissection that is not detectable by TEE. False-Positive Results The path of ultrasound through the esophageal wall and surrounding tissues may generate near-field artifacts that are often disconcertingly linear and run parallel to the aortic wall, mimicking an intimal flap. In patients with severe atherosclerotic disease, calcification in the wall can present similar artifacts and shadows. Abrupt aortic dilation can create a "shelf," which can resemble a flap as well. Determining that these do not represent true intimal flaps depends on recognizing the minimal mobility of these "structures" and the homogeneity of flow on both sides of the line. The ability to change to a second imaging plane, as is possible with biplane or multiple-plane TEE
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
probes, is extremely helpful in resolving the issue of artifactual "flaps."[86] [114] Multiple-plane imaging also allows better visualization of the proximal ascending aorta, where atherosclerosis and ectasia can be misinterpreted as dissection.[77] Aneurysmal dilation of the aorta is another source of false-positive TEE studies for dissection. Flow in aneurysmal areas is often low-velocity and swirling, similar to the flow in false channels. The absence of an intimal flap is important in avoiding misdiagnosis in this situation. The possibility that the intimal flap is not seen because the false channel has thrombosed must be excluded by carefully scanning up and down the aorta from the abnormal site. An intimal layer identified proximally or distally may be followed back to the suspicious dilated segment to suggest dissection.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/28.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Alternative Approaches to the Diagnosis of Dissection Echocardiography is only one of several diagnostic tests for dissection. The choice of imaging procedure, as well as the clinical confidence in positive or negative results, needs to be gauged relative to the test's performance (see Table 3-3) . Angiography is a time-honored diagnostic method for aortic dissection that may identify the intimal flap and false lumen. In addition, it can define coronary and great vessel ostial involvement. Its sensitivity and specificity for dissection (88% and 94%, respectively) are limited by false lumen thrombosis, intramural hematomas, and equal flow in true and false lumens.[115] [116] The last case is also an important limitation for CT studies, in which differential flow may not be detectable even with dynamic CT imaging.[117] The lower sensitivity (83%) of CT reflects its poor definition of the intimal flap and entry tear. Despite CT's high specificity (90% to 100%), a negative CT result in the presence of high clinical suspicion of dissection requires a second confirmatory test. Extremely slow, swirling flow within a segment of the false channel may not be completely differentiated from thrombus by MRI.[118] MRI's excellent definition of the important components of aortic dissection have resulted in its excellent sensitivity, however, which approaches 100%.[119] The pragmatic issues of imaging acutely ill patients with needs for hemodynamic monitoring or infusion of medications or those at risk for hemodynamic collapse continue to make TEE preferable in many acute settings. As mentioned earlier, MRI may be the procedure of choice for the follow-up of patients with repaired or chronic dissections.
60
In their comparison of angiography, TEE, CT, and MRI techniques for aortic dissection, Barbant et al[120] used data from several published series to compare the accuracy and predictive value of these tests in populations
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
with high, intermediate, and low prevalence of disease. For populations with a high risk of dissection, positive predictive values for all tests exceeded 85%. In intermediaterisk populations (prevalence, 10%), positive predictive values were greater than 90% for CT, MRI, and TEE but less than 65% for angiography. When the disease prevalence was low (1%), as it probably is in most clinical applications of these tests, the positive predictive values were less than 50% for angiography, CT, and TEE, and remained high only for MRI (100%). In any population, the negative predictive value was greater than or equal to 85% for all tests. These results suggest that TEE and other imaging techniques may not perform as well in a low-risk ambulatory population, as suggested by published results from higher-prevalence populations.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/29.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Research Applications and Future Directions Transesophageal echocardiographic images provide excellent spatial resolution, especially with the higher frequencies that are becoming available. Combining this with the high temporal resolution of M-mode methods has allowed investigation of aortic distensibility in normal patients, in patients at risk for vascular disease, and after repair of aneurysms or dissection. These types of methods have documented decreases in elastic aortic properties after aortic surgery, which predispose patients to redissection.[121] Two-dimensional echocardiographic assessments of aortic distensibility have been shown to estimate changes in aortic mechanical properties resulting from increasing age[122] Doppler estimates of pulse wave velocity Figure 3-14 Three-dimensional constructed views of the aorta in shortaxis (left) and long-axis (right) orientations demonstrate the intimal flap separating true and false lumens.
are also being investigated as measures of aortic compliance.[123] Animal models for validation of these parameters include chronic models of accelerated atherogenesis, as well as acute aortic ischemia and decreased distensibility generated by removal of the vasa vasorum.[124] High-frequency ultrasonic integrated backscatter methods are also being applied to the aortic wall (see Chapter 9) . Recchia et al[125] detected sixfold decreases in backscatter and 15-fold decreases in anisotropy, suggesting marked disorganization of the three-dimensional aortic architecture in the aortas of Marfan's syndrome patients as compared with the aortas of normal patients. These types of functional and structural investigations may improve our recognition of aortic disease of many stages and refine our prediction of risk of dissection. Technologic advances in aortic visualization are occurring based on
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
improved transducer designs with more elements, greater freedom in imaging plane, and higher frequencies. These will be the basis for expanding the role of echocardiography in caring for aortic dissection patients, who will be undergoing new types of surgery involving new developments such as stents, balloon fenestration, and aortic valve resuspension.[126] Intravascular ultrasonography has become an extremely important imaging technique within the coronary vessels ( see Chapter 15 Chapter 16 ). Expanding this technology to the larger vessels and cardiac chambers has required lower-frequency transducers.[127] The potentially powerful role of intravascular ultrasonography in combination with angiography may have an important effect on the sensitivity of that technique. Similarly, tissue characterization with ultrasonography may be useful in identifying abnormalities of vessel wall composition, architecture, and material properties and aid in the prediction of primary or secondary dissection events. New ultrasonographic contrast agents that pass from venous injections through the pulmonary bed and into 61
the left-sided circulation may potentially aid in defining entry tears and important communications between true and false lumens.[128] [129] This improved spatial information will also be greatly aided by threedimensional constructs that can be generated from tomographic echocardiographic acquisitions (Fig. 3-14) .[130]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/30.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Summary The grim prognosis of patients with undetected acute aortic dissection demands a rapid, highly sensitive, and efficient diagnostic approach. Transesophageal imaging has excellent sensitivity for aortic dissection, its multiple complications, and its imitators. Intraoperatively, TEE or epicardial imaging identifies surgically relevant features of aortic valve damage and ventricular function. Patients with postoperative or chronic dissection can be followed with TEE, and serious events such as expansion or redissection can be quickly defined when symptoms of recurrent pain appear. Echocardiography is already established as a mainstay in the emergent diagnosis, treatment, and follow-up of patients with acute and chronic aortic dissection, and new technologies and applications will continue to expand its role in the future.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/31.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 11
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
References 1. Chirillo F, Marchiori MC, Andriolo L, et al: Outcome of 290 patients with aortic
dissection: A 12 year multicentre experience. Eur Heart J 1990;11:311–319. 2. Demos TC, Posniak HV, Marsan RE: CT of aortic dissection. Semin Roentgenol
1989;24:22–37. 3. Lilienfeld DE, Gunderson PD, Sprafka JM, et al: Epidemiology of aortic aneurysms:
1. Mortality trends in the United States, 1951–1981. Arteriosclerosis 1987;7:637–643. 4. Satler FL, Levine S, Kent KM, et al: Aortic dissection masquerading as acute
myocardial infarction: Implication for thrombolytic therapy without cardiac catheterization. Am J Cardiol 1984;54:1134–1145. 5. Davidson E, Weinberger I, Rotenberg Z, et al: Elevated serum creatinine kinase
levels: An early diagnostic sign of acute dissection of the aorta. Arch Intern Med 1988;148:2184–2186. 6. Hirst AE, Johns VJ, Kime SW: Dissecting aneurysm of the aorta: A review of 505
cases. Medicine 1958;37:217–279. 7. Wilcox RG, Olsson CG, Skene AM, et al: Trial of plasminogen activator for
mortality reduction in acute myocardial infarction. Lancet 1988;2:525–530. 8. Butler J, Davies AH, Westaby S: Streptokinase in acute aortic dissection. Br Med J
1990;300:517–519. 9. Weiss P, Weiss I, Zuber M, Ritz R: How many patients with acute dissection of the
thoracic aorta would erroneously receive thrombolytic therapy based on the electrocardiographic findings on admission? Am J Cardiol 1993;72:1329–1330.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 11
10. Lee RT, Kamm RD: Vascular mechanics for the cardiologist. J Am Coll Cardiol
1994;23:1289–1295. 11. Mukherjee DP, Kagan HM, Jordan RE, Franzblau C: Effect of hydrophobic elastin
ligands on the stress-strain properties of elastin fibers. Connect Tissue Res 1976;4:177–179. 12. Buntin CM, Silver FH: Noninvasive assessment of mechanical properties of
peripheral arteries. Ann Biomed Eng 1990;18:549–566. 13. Dzau VJ, Safar ME: Large conduit arteries in hypertension: Role of the vascular
renin-angiotensin system. Circulation 1988;77:947–954. 14. Yoganathan AP, Cape EG, Sung HW, et al: Review of hydrodynamic principles for
the cardiologist: Applications to the study of blood flow and jets by imaging techniques. J Am Coll Cardiol 1988;12:1344–1353. 15. Robicsek F, Thubrikar MJ: Hemodynamic considerations regarding the mechanism
and prevention of aortic dissection. Ann Thorac Surg 1994;58:1247–1253. 16. MacSweeney ST, Young G, Greenhalgh RM, Powell JT: Mechanical properties of
the aneurysmal aorta. Br J Surg 1992;79:1281–1284. 17. Carson MW, Roach MR: The strength of the aortic media and its role in the
propagation of aortic dissection. J Biomech 1990;23:579–588. 18. Rubin K: Aortic dissection and rupture in Turner syndrome. J Pediatr
1993;122:670. 19. Ashraf SS, Shaukat N, Masood M, et al: Type I aortic dissection in a patient with
osteogenesis imperfecta. Eur J Cardiothorac Surg 1993;7:665–666. 20. Singer A, Cooke JP: Aortic aneurysm. In Cooke JP, Frolich ED (eds): Current
Management of Hypertensive and Vascular Diseases. Philadelphia, BC Decker, 1992, pp 166–171. 21. Cooke JP, Kazimer FJ, Orszulak TA: The penetrating aortic ulcer: Pathology,
diagnosis and management. Mayo Clin Proc 1988;63:718–725. 22. Harris JA, Bis KG, Glover JL, et al: Penetrating atherosclerotic ulcers of the aorta
[discussion, pp 98–99]. J Vasc Surg 1994;19:90–98. 23. Pretre R, Chilcott M: Blunt trauma to the heart and great vessels. N Engl J Med
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 11
1997;336:626–632. 24. Vlahakes GJ, Warren RL: Traumatic rupture of the aorta. N Engl J Med
1995;332:389–390. 25. Parmley LF, Mattingly TW, Manion WC, et al: Nonpenetrating traumatic injury of
the aorta. Circulation 1958;17:1086–1101. 26. Smith MD, Cassidy JM, Souther S, et al: Transesophageal echocardiography in the
diagnosis of traumatic rupture of the aorta. N Engl J Med 1995;332:356–362. 27. Pieters FA, Widdershoven JW, Gerardy AC, et al: Risk of aortic dissection after
aortic valve replacement. Am J Cardiol 1993;72:1043–1047. 28. Katz ES, Tunick PA, Colvin SB, et al: Aortic dissection complicating cardiac
surgery: Diagnosis by intraoperative biplane transesophageal echocardiography. J Am Soc Echocardiogr 1993;6:217–222. 29. Sakamoto I, Hayashi K, Matsunaga N, et al: Aortic dissection caused by
angiographic procedures. Radiology 1994;191:467–471. 30. Dorsey DM, Rose SC: Extensive aortic and renal artery dissection following
percutaneous transluminal angioplasty. J Vasc Interv Radiol 1993;4:493–495. 31. Braunwald E: Heart Disease. Philadelphia, WB Saunders, 1992, pp 1536–1551. 32. Nolte JE, Rutherford RB, Nawaz S, et al: Arterial dissections associated with
pregnancy. J Vasc Surg 1995;21:515–520. 33. Roberts WC: Aortic dissection: Anatomy, consequences and causes. Am Heart J
1981;101:195–241. 34. Oskoui R, Lindsay J Jr: Aortic dissection in women less than 40 years of age and
the unimportance of pregnancy. Am J Cardiol 1994;73(11):821–823. 35. McDermott JC, Schuster MR, Crummy AB, Acher CW: Crack and aortic
dissection. Wisc Med J 1993;92:453–455. 36. Das G: Cardiovascular effects of cocaine abuse. Int J Clin Pharmacol Ther Toxicol
1993;31:521–528. 37. Biagini A, Maffei S, Baroni M, et al: Familiar clustering of aortic dissection in
polycystic kidney disease. Am J Cardiol 1993;72:741–742.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 11
38. Schor JS, Horowitz MD, Livingstone AS: Recreational weight lifting and aortic
dissection: Case report. J Vasc Surg 1993;17:774–776. 39. Chauvel C, Cohen A, Albo C, et al: Aortic dissection and cardiovascular syphilis:
Report of an observation with transesophageal echocardiography and anatomopathologic findings. J Am Soc Echocardiogr 1994;7:419–421. 40. Eber B, Tscheliessnigg KH, Anelli-Monti M, et al: Aortic dissection due to
discontinuation of beta-blocker therapy. Cardiology 1993;83:128–131. 41. Evans JM, Bowles CA, Bjornsson J, et al: Thoracic aortic aneurysm and rupture in
giant cell arteritis: A descriptive study of 41 cases. Arthritis Rheum 1994;37:1539– 1547. 62
42. Gersbach P, Lang H, Kipfer B, et al: Impending rupture of the ascending aorta due
to giant cell arteritis. Eur J Cardiothorac Surg 1993;7:667–670. 43. Marsalese DL, Moodie DS, Lytle BW, et al: Cystic medial necrosis of the aorta in
patients without Marfan's syndrome: Surgical outcome and long-term follow-up. J Am Coll Cardiol 1990;16:68–73. 44. Child AH: Marfan syndrome—current medical and genetic knowledge: How to
treat and when. J Card Surg 1997;12(2 suppl):131–135. 45. McDonald GR, Schaff HV, Pyeritz RE, et al: Surgical management of patients with
Marfan syndrome and dilatation of the ascending aorta. J Thorac Cardiovasc Surg 1981;81:180–186. 46. Murdoch JL, Walker BA, Halpern BL, et al: Life expectancy and causes of death in
the Marfan syndrome. N Engl J Med 1972;286:804–808. 47. Gott VL, Laschinger JC, Cameron DE, et al: The Marfan syndrome and the
cardiovascular surgeon. Eur J Cardiothorac Surg 1996;10:149–158. 48. Pyeritz RE, McKusick VA: The Marfan syndrome diagnosis and management. N
Engl J Med 1979;300:772–777. 49. Hollister DW, Godfrey M, Sakai LY, Pyeritz RE: Immunohistologic abnormalities
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 11
of the microfibrillar-fiber system in the Marfan syndrome. N Engl J Med 1990;323:152–159. 50. Hirata K, Triposkiadis F, Sparks E, et al: The Marfan syndrome: Abnormal aortic
elastic properties. J Am Coll Cardiol 1991;18:57–63. 51. Jeremy RW, Huang H, Hwa J, et al: Relation between age, arterial distensibility,
and aortic dilatation in the Marfan syndrome. Am J Cardiol 1994;74:369–373. 52. Come PC, Fortuin NJ, White RI, McKusick VA: Echocardiographic assessment of
cardiovascular abnormalities in the Marfan syndrome: Comparison with clinical findings and with roentgenographic estimation of aortic root size. Am J Med 1983;74:465–474. 53. Brown OR, DeMots H, Kloster FE, et al: Aortic root dilatation and mitral valve
prolapse in Marfan's syndrome: An echocardiographic study. Circulation 1975;52:651–657. 54. Roman MJ, Rosen SE, Kramer-Fox R, Devereux RB: Prognostic significance of
the pattern of aortic root dilation in the Marfan syndrome. J Am Coll Cardiol 1993;22:1470–1476. 55. Legget ME, Unger TA, O'Sullivan CK, et al: Aortic root complications in the
Marfan's syndrome: Identification of a lower risk group. Heart 1996;75:389–395. 56. Gott VL, Pyeritz RE, Magovern GJ Jr, et al: Surgical treatment of aneurysms of the
ascending aorta in the Marfan syndrome: Results of composite-graft repair in 50 patients. N Engl J Med 1986;314:1070–1074. 57. Pyeritz RE: Predictors of dissection of the ascending aorta in Marfan syndrome
[abstract]. Circulation 1991;84(suppl II):II-351. 58. Roberts WC, Honig HS: The spectrum of cardiovascular disease in the Marfan
syndrome: A clinicomorphologic study of 18 necropsy patients and comparison to 151 previously reported necropsy patients. Am Heart J 1982;104:115–135. 59. Groenink M, Lohuis TA, Tijssen JG, et al: Survival and complication free survival
in Marfan's syndrome: Implications of current guidelines. Heart 1999;82:499–504. 60. Gott VL, Greene PS, Alejo DE, et al: Replacement of the aortic root in patients
with Marfan's syndrome. N Engl J Med 1999;29;340:1307–1313. 61. Coselli JS, LeMaire SA, Buket S: Marfan syndrome: The variability and outcome
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 11
of operative management. J Vasc Surg 1995;21:432–443. 62. Tambeur L, David TE, Unger M, et al: Results of surgery for aortic root aneurysm
in patients with the Marfan syndrome. Eur J Cardiothorac Surg 2000;17:415–419. 63. Svensson LG, Labib SB: Aortic dissection and aortic aneurysm surgery. Curr Opin
Cardiol 1994;9:191–199. 64. DeBakey ME, McCollum CH, Crawford ES, et al: Dissection and dissecting
aneurysms of the aorta: Twenty year follow-up of five hundred twenty seven patients treated surgically. Surgery 1982;92:1118–1134. 65. Daily PO, Trueblood HW, Stinson EB, et al: Management of acute aortic
dissections. Ann Thorac Surg 1970;10:237–247. 66. Miller DC: Surgical management of aortic dissections: Indications, perioperative
management, and long term results. In Doroghazi RM, Slater EE (eds): Aortic Dissection. New York, McGraw-Hill, 1983, pp 193–243. 67. Applebaum A, Karp RB, Kirklin JW: Ascending vs. descending aortic dissections.
Ann Surg 1976;183:296. 68. DeSanctis RW, Doroghazi RM, Austen WG, Bucklet MJ: Aortic dissection. N
Engl J Med 1987;317:1060–1067. 69. Miller DC: Acute dissection of the descending thoracic aorta. Chest Surg Clin
North Am 1992;2:347–378. 70. Dinsmore RE, Willerson JT: Dissecting aneurysms of the aorta: Angiographic
features affecting prognosis. Radiology 1972;105:567. 71. Miller DC: Improved follow-up for patients with chronic dissections. Semin
Thorac Cardiovasc Surg 1991;3:270–276. 72. Roberts CS, Roberts WC: Aortic dissection with the entrance tear in the
descending thoracic aorta: Analysis of 40 necropsy patients. Ann Surg 1991;213:356– 368. 73. Duch PM, Chandrasekaran K, Karalis DG, Ross JJ Jr: Improved diagnosis of
coexisting types II and III aortic dissection with multiplane transesophageal echocardiography. Am Heart J 1994;127:699–701. 74. Slater EE: Aortic dissection: Presentation and diagnosis. In Doroghazi RM, Slater
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 11
EE (eds): Aortic Dissection. New York, McGraw-Hill, 1983, pp 61–70. 75. Wheat MW Jr: Intensive drug therapy. In Doroghazi RM, Slater EE (eds): Aortic
Dissection. New York, McGraw-Hill, 1983, pp 165–192. 76. Grossman CM, D'Agostino AN: Advanced atherosclerosis in false channels of
chronic aortic dissection. Lancet 1993;342:1428–1429. 77. Erbel R, Engberding R, Daniel W, et al: Echocardiography in diagnosis of aortic
dissection. Lancet 1989;1:457–461. 78. Nienaber CA, Spielmann RP, von Kodolitsch Y, et al: Diagnosis of thoracic aortic
dissection: Magnetic resonance imaging versus transesophageal echocardiography. Circulation 1992;85:434–447. 79. Nienaber CA, von Kodolitsch Y, Nicolas V, et al: The diagnosis of thoracic aortic
dissection by noninvasive imaging procedures. N Engl J Med 1993;328:1–9. 80. Victor MF, Mintz GS, Kotler MN, et al: Two-dimensional echocardiographic
diagnosis of aortic dissection. Am J Cardiol 1981;48:1155–1159. 81. Movsowitz HD, Levine RA, Hilgenberg AD, et al: Transesophageal
echocardiographic description of the mechanisms of aortic regurgitation in acute type A aortic dissection: Implications for aortic valve repair. J Am Coll Cardiol 2000;36:884–890. 82. Geibel A, Kasper W, Behroz A, et al: Risk of transesophageal echocardiography in
awake patients with cardiac diseases. Am J Cardiol 1988;62:337–339. 83. Silvey SV, Stroughton TL, Pearl W, et al: Rupture of the outer partition of aortic
dissection during transesophageal echocardiography. Am J Cardiol 1991;68:286–287. 84. Pearson AC, Castello R, Labovitz AJ: Safety and utility of transesophageal
echocardiography in the critically ill patient. Am Heart J 1990;119:1083–1089. 85. Iliceto S, Nanda NC, Rizzon P, et al: Color Doppler evaluation of aortic dissection.
Circulation 1987;75:748–755. 86. Appelbe AF, Walker PG, Yeoh JK, et al: Clinical significance and origin of
artifacts in transesophageal echocardiography of the thoracic aorta. J Am Coll Cardiol 1993;21:754–760. 87. Chan KL: Usefulness of transesophageal echocardiography in the diagnosis of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 11
conditions mimicking aortic dissection. Am Heart J 1991;122:495–504. 88. Erbel R, Mohr-Kahaly S, Rennollet H, et al: Diagnosis of aortic dissection: The
value of transesophageal echocardiography. Thorac Cardiovasc Surg 1987;35:126– 133. 89. Mohr-Kahaly S, Erbel R, Rennollet H, et al: Ambulatory follow-up of aortic dissection by transesophageal two-dimensional and color-coded Doppler echocardiography. Circulation 1989;80:24–33. 90. Adachi H, Kyo S, Takamoto S, et al: Early diagnosis and surgical intervention of
acute aortic dissection by transesophageal color flow mapping. Circulation 1990;82 (suppl 4):19–23. 91. Eichelberger JP: Aortic dissection without intimal tear: Case report and findings on
transesophageal echocardiography. J Am Soc Echocardiogr 1994;7:82–86. 63
92. Yamada T, Tada S, Harada J: Aortic dissection without intimal rupture: Diagnosis
with MR imaging and CT. Radiology 1988;168:347–352. 93. Mohr-Kahaly S, Erbel R, Kearney P, et al: Aortic intramural hemorrhage
visualized by transesophageal echocardiography: Findings and prognostic implications. J Am Coll Cardiol 1994;23:658–664. 94. Erbel R, Oelert H, Meyer J, et al: Effect of medical and surgical therapy on aortic
dissection evaluated by transesophageal echocardiography: Implications for prognosis and therapy. The European Cooperative Study Group on Echocardiography. Circulation 1993;87:1604–1615. 95. Robbins RC, McManus RP, Mitchell RS, et al: Management of patients with
intramural hematoma of the thoracic aorta. Circulation 1993;88:II1–II10. 96. Crawford ES: The diagnosis and management of aortic dissection. JAMA
1990;264:2537–2541. 97. Ballal RS, Nanda NC, Gatewood R, et al: Usefulness of transesophageal
echocardiography in assessment of aortic dissection. Circulation 1991;84:1903–1914. 98. Penn MS, Smedira N, Lytle B, et al: Does coronary angiography before emergency
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 11
aortic surgery affect in-hospital mortality? J Am Coll Cardiol 2000;35:889–894. 99. Nakatani S, Beppu S, Tanaka N, et al: Application of abdominal and
transesophageal echocardiography as a guide for insertion of intraaortic balloon pump in aortic dissection. Am J Cardiol 1989;64:1082–1083. 100. Niinami H, Aomi S, Tagusari O, et al: Extensive aortic reconstruction for aortic
aneurysms in Marfan syndrome. Ann Thorac Surg 1999;67:1864–1867. 101. Mazzucotelli JP, Deleuze PH, Baufreton C, et al: Preservation of the aortic valve
in acute aortic dissection: Long-term echocardiographic assessment and clinical outcome. Ann Thorac Surg 1993;55:1513–1517. 102. Neustein SM, Lansman SL, Quintana CS, et al: Transesophageal Doppler
echocardiographic monitoring for malperfusion during aortic dissection repair. Ann Thorac Surg 1993;56:358–361. 103. Laissy JP, Blanc F, Soyer P, et al: Thoracic aortic dissection: Diagnosis with
transesophageal echocardiography versus MR imaging. Radiology 1995;194:331–336.
104. Dinsmore RE, Willerson JT: Dissecting aneurysms of the aorta: Angiographic
features affecting prognosis. Radiology 1972;105:567–572. 105. Heinemann M, Laas J, Karck M, Borst HG: Thoracic aortic aneurysms after acute
type A aortic dissection: Necessity for follow-up. Ann Thorac Surg 1990;49:580–584.
106. Barbetseas J, Crawford S, Safi HJ, et al: Doppler echocardiographic evaluation of
pseudoaneurysms complicating composite grafts of the ascending aorta. Circulation 1992;85:212–222. 107. Vilacosta I, Camino A, San Roman JA, et al: Supravalvular aortic stenosis after
replacement of the ascending aorta. Am J Cardiol 1992;70:1505–1507. 108. San Roman JA, Vilacosta I, Castillo JA, et al: Role of transesophageal
echocardiography in the assessment of patients with composite aortic grafts for therapy in acute aortic dissection. Am J Cardiol 1994;73:519–521. 109. Nath PH, Zollikofer C, Castaneda-Zuniga WR, et al: Radiological evaluation of
composite aortic grafts. Radiology 1979;131:43–51. 110. Pucillo AL, Schechter AG, Moggio RA, et al: Postoperative evaluation of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 11
ascending aortic prosthetic conduits by magnetic resonance imaging. Chest 1990;97:106–110. 111. Simon P, Owen AN, Moidl R, et al: Sinus of Valsalva aneurysm: A late
complication after repair of ascending aortic dissection. Thorac Cardiovasc Surg 1994;42:29–31. 112. Haverich A, Miller DC, Scott WC, et al: Acute and chronic aortic dissections:
Determinant of long-term outcome for operative survivors. Circulation 1985;72(suppl 2):22–34. 113. Chan KL: Impact of transesophageal echocardiography on the treatment of
patients with aortic dissection. Chest 1992;101:406–410. 114. Adachi H, Omoto R, Kyo S, et al: Emergency surgical intervention of acute aortic
dissection with the rapid diagnosis by transesophageal echocardiography. Circulation 1991;84(suppl 3):14–19. 115. Cigarroa JE, Isselbacher EM, DeSanctis RW, Eagle KA: Diagnostic imaging in
the evaluation of suspected aortic dissection: Old standards and new directions. N Engl J Med 1993;328:35–43. 116. Bansal RC, Chandrasekaran K, Ayala K, Smith DC: Frequency and explanation of
false negative diagnosis of aortic dissection by aortography and transesophageal echocardiography. J Am Coll Cardiol 1995;25:1393–1401. 117. Mugge A, Daniel WG, Laas J, et al: False-negative diagnosis of proximal aortic
dissection by computed tomography or angiography and possible explanations based on transesophageal echocardiographic findings. Am J Cardiol 1990;65:527–529. 118. Barzilai B, Waggoner AD: Diagnosis of aortic dissection with transesophageal
echocardiography. Cardiology 1991;91:73–83. 119. Laissy JP, Blanc F, Soyer P, et al: Thoracic aortic dissection: Diagnosis with
transesophageal echocardiography versus MR imaging. Radiology 1995;194:331–336.
120. Barbant SD, Eisenberg MJ, Schiller NB: The diagnostic value of imaging
techniques for aortic dissection. Am Heart J 1992;124:541–543. 121. Imawaki S, Maeta H, Shiraishi Y, et al: Decrease in aortic distensibility after an
extended aortic reconstruction for Marfan's syndrome as a cause of postoperative acute aortic dissection DeBakey type I: A report of two cases. Surg Today
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 11
1993;23:1010–1013. 122. Lacombe F, Dart A, Dewar E, et al: Arterial elastic properties in man: A
comparison of echo-Doppler indices of aortic stiffness. Eur Heart J 1992;13:1040– 1045. 123. Lehmann ED, Hopkins KD, Gosling RG: Aortic compliance measurements using Doppler ultrasound: In vivo biochemical correlates. Ultrasound Med Biol 1993;19:683–710. 124. Stefanadis CI, Karayannacos PE, Boudoulas HK, et al: Medial necrosis and acute
alterations in aortic distensibility following removal of the vasa vasorum of canine ascending aorta. Cardiovasc Res 1993;27:951–956. 125. Recchia D, Sharkey AM, Bosner MS, et al: Sensitive detection of abnormal aortic
architecture in Marfan syndrome with high-frequency ultrasonic tissue characterization. Circulation 1995;91:1036–1043. 126. Peterson AH, Williams DM, Rodriguez JL, Francis IR: Percutaneous treatment of
a traumatic aortic dissection by balloon fenestration and stent placement. Am J Roentgenol 1995;164:1274–1276. 127. Weintraub AR, Schwartz SL, Pandian NG, et al: Evaluation of acute aortic
dissection by intravascular ultrasonography. N Engl J Med 1990;323:1566–1567. 128. McRee D, Matsuda M, Stratton J, et al: Transthoracic contrast echocardiographic
detection of ascending aortic dissection. J Am Soc Echocardiogr 1999;12:1122–1124. 129. Kimura BJ, Phan JN, Housman LB: Utility of contrast echocardiography in the
diagnosis of aortic dissection. J Am Soc Echocardiogr 1999;12:155–159. 130. Sugeng L, Cao QL, Delabays A, et al: Three-dimensional echocardiographic
evaluation of aortic disorders with rotational multiplanar imaging: Experimental and clinical studies. J Am Soc Echocardiogr 199;10:120–132.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/32.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 5
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Section 2 - The Left Ventricle 65
Chapter 4 - Quantitative Evaluation of Left Ventricular Structure, Wall Stress, and Systolic Function Gerard P. Aurigemma MD Pamela S. Douglas MD William H. Gaasch MD
The quantitation of left ventricular (LV) systolic function, size, and geometry is critical to the proper evaluation and management of patients with all types of heart disease.[1] For example, the assessment of LV function in patients with coronary artery disease provides better prognostic information than does knowledge of the number of diseased vessels (Fig. 41) . Even when only one or two vessels are diseased, a low ejection fraction (EF) is associated with a higher mortality than that seen in patients with three-vessel disease and a normal EF.[2] Large LV systolic and diastolic volumes are also associated with a poor prognosis[3] [4] thus, a patient with a reduced EF after a myocardial infarction can be categorized according to subsequent risk based on the absolute end-systolic volume (Fig. 4-2) . Furthermore, information concerning LV size and geometry has important
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 5
therapeutic implications, in view of the salutary effects of therapy with angiotensin converting enzyme inhibitors on postinfarction remodeling and prognosis in patients with a reduced EF.[5] Similarly, in cardiomyopathy of any cause, mortality remains high in patients with an EF less than 35%,[6] [7] even with medical therapy. A depressed EF is uniformly present in patients with idiopathic dilated cardiomyopathy and is due to a combination of afterload excess and depressed contractility. In this setting, indices of LV geometry, such as the relative wall thickness or the mass/volume ratio (Fig. 4-3) , provide prognostic information that is independent of the EF.[8] Conversely, it is important to identify the significant percentage of patients with congestive heart failure symptoms who have a normal EF.[9] [10] Measurement of LV volume, mass, and function can provide data that are necessary to define the optimal time for surgery in patients with volume overload hypertrophy owing to chronic, severe mitral or aortic regurgitation. In this regard, the prognostic usefulness of ventricular enddiastolic and end-systolic volumes, the EF, the ratio of end-diastolic volume to mass, systolic stress-shortening relations, and end-systolic pressure-volume relations has been tested in a variety of clinical studies. The end-systolic volume and EF appear to provide the most useful clues to prognosis.[11] [12] [13] [14] [15] [16] [17] [18] [19] [20] Certainly, a most important determinant of postoperative survival is the level of LV systolic function (Fig. 4-4) (Figure Not Available) . In pressure overload hypertrophy owing to aortic stenosis, an assessment of systolic function is perhaps less important than in the regurgitant lesions. Although severe depression of the EF may indicate an increased surgical risk, patients with an EF as low as 20% to 25% can show substantial clinical improvement after aortic valve replacement.[21] [22] [23] In such patients, excessive systolic loads are usually responsible for the low EF; this situation is termed inadequate hypertrophy or afterload excess. Alternatively, 66
Figure 4-1 The relation between left ventricular ejection fraction (EF) and survival in patients with single-, double-, and triple-vessel coronary artery disease (CAD). The negative impact of a low EF is seen in all three groups. Survival is better in patients with three-vessel CAD and a
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 5
normal EF than in those with one- or two-vessel disease and a low EF. (Adapted from Mock MB, Rindqvist I, Fisher LD, et al: Circulation 1982;66:562–567. From Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:368.) Figure 4-2 The relation between left ventricular end-systolic volume (ESV) and survival in patients with normal, near-normal, and abnormal ejection fraction (EF). Data were obtained from patients with a history of myocardial infarction. ESV is a major predictor of survival when the EF is less than 50%. (Adapted from White HD, Norris RM, Brown MA, et al: Circulation 1987;76:44–51. From Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:369.) Figure 4-3 The relation between left ventricular mass/volume (M/V) ratio and survival in patients with an ejection fraction (EF) higher than and less than 20%. Data were obtained from patients with dilated cardiomyopathy. Patients with a normal M/V ratio exhibit better survival than those with a low ratio; this trend is seen in EF categories. (Adapted from Feild BJ, Baxley WA, Russell RO Jr, et al: Circulation 1973;47:1022–1031. From Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:370.)
67
Figure 4-4 (Figure Not Available) Relation of preoperative ventricular function to postoperative survival. These and other published data (see text) indicated that preoperative ventricular function is an important determinant of postoperative survival. ESD (echo), end-systolic dimension by echocardiography; SEF (angio), systolic ejection fraction by angiography; SEF (echo), systolic ejection fraction by echocardiography. (Adapted from Hoshino PK, Gaasch WH: Arch Intern Med 1986;146:349–352. Copyright © 1986 American Medical Association. From Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:371.)
excessive or inappropriate hypertrophy, indicated by a high relative wall thickness, appears to identify a group of patients having a high perioperative risk[24] [25] in this situation, a normal or high EF does not seem to be beneficial. In aortic stenosis, therefore, indices of LV geometry[26] (relative wall thickness) appear to provide prognostic clues that are not reflected in the EF. It is well established that increased LV mass is a strong predictor of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 5
cardiovascular morbidity as well as cardiovascular and all-cause mortality, even when age, blood pressure, and other risk factors are considered[27] [28] [29] [30] [31] [32] (see Chapter 32) . Some investigators have suggested that LV geometry provides prognostic information that is incremental to the extent of LV hypertrophy.[29] [30] [31] For example, an increased ratio of LV wall thickness to cavity dimension[32] identifies patients at higher risk for cardiovascular morbidity and mortality (Table 4-1) ; whether this incremental risk is truly independent of LV mass has been called into question by other data.[33] Thus, a substantial body of clinical research has demonstrated the prognostic value of indices of LV volume, mass, geometry, and function. Most if not all of these indices are routinely available to the clinician from standard M-mode and two-dimensional (2D) and Doppler echocardiography. In this chapter the echocardiographic techniques for evaluating LV geometry, stress, and systolic function are reviewed. Principles and methods are discussed, TABLE 4-1 -- Relation Between Morbid Events and the Pattern of Left Ventricular Geometry Normal LV Mass LVH P RWT ≥ RWT < RWT ≥ RWT < 0.45 (N = 0.45 (N = 0.45 (N = 0.45 (N = 29) 40) 34) 150) 0 3 10 21 < .001
CV deaths (%) CV events 11 15 23 31 .03 (%) All deaths 1 6 10 24 < .01 (%) The prognostic value of LVH for morbid events in men (at an average of 10.2 years of follow-up) is striking. For all end points, the RWT provides incremental value for assessing risk. P-value obtained by analysis of variance. CV, cardiovascular; LVH, left ventricular hypertrophy; RWT, relative wall thickness. From Koren M, Devereux R, Casale PN, et al: Ann Intern Med 1991;114:345–352.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 7
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Definitions and Theoretical Considerations The systolic pumping of the left ventricle is a complex process that involves a coordinated contraction of subendocardial, midwall, and subepicardial muscle fibers. These fibers are arranged in a complex, helical fashion. At the equator of the ventricle, midwall fibers are oriented circumferentially; contraction of these fibers mainly contributes to a decrease in the minor axis (or dimension) of the ventricle and is responsible for generation of much of the stroke volume (Fig. 4-5) . Longitudinally oriented fibers in the subendocardium and subepicardium contribute to shortening of the long axis of the ventricle, also contributing to stroke volume. In addition to circumferential and long-axis shortening, the apex of the left ventricle rotates counterclockwise during systolic contraction, and the base rotates clockwise (as viewed from the apex).[34] [35] Such "twist," like fiber shortening, appears to be influenced by the contractile state of the myocardium. In concert with these shortening and twisting motions, wall thickening contributes to volume displacement and generation of the stroke volume.[36] Preload, afterload, contractility, and geometry influence shortening and thickening.[37] The pumping activity of the left ventricle provides oxygenated blood to the tissues of the body; therefore, the stroke volume can be used as a parameter of the pump performance of the ventricle (Table 4-2) . Because LV systolic pressure and stroke volume are inversely related, using stroke work as an index of ventricular performance can be more appropriate; a stroke work parameter credits the ventricle for the development of pressure and for shortening. When performance is assessed relative to end-diastolic fiber length or a related parameter, ventricular function can be described. Thus, a ventricular function curve can be generated by plotting stroke work against end-diastolic pressure, diameter, volume, or wall stress. Volume loading therefore produces an increment in stroke work (i.e., performance) through use of the Frank-Starling
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 7
68
Figure 4-5 Circumferential and longitudinal fibers contribute to wall thickening and volume displacement. These functions are influenced by left ventricular preload, afterload, contractile state, and geometry. (From Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:374.)
mechanism. By contrast, increased myocardial contractility also can produce an increment in stroke work, but in this case performance is augmented through a change in inotropic state rather than by a change in end-diastolic fiber length. In other words, contractility refers to a basic property of the myocardium that reflects the intensity of its active state. The use of the term contractility should be restricted to situations in which a change in performance or EF cannot be ascribed to a change in preload or afterload. Contractile function is a more general term used to describe changes in performance or function that could be affected by changes in inotropic state, fiber length, or loads. Thus, a change in the EF might best be classified as a change in contractile function; this term is often used interchangeably with systolic function. To fully describe the ventricle, it is necessary to define several additional terms that refer to its mechanical properties. Stress is defined as the force per unit cross-sectional area of a material. It is an engineering term used to compare loads borne by different-sized elements of a material; the total load is less important than the load per unit of material. If the same load is borne by a smaller amount of material, the stress on that material is higher. In a spherical model of the left ventricle, wall stress (σ) is directly proportional to the transmural pressure (P) and inversely proportional to the product of chamber radius (R) and wall thickness (Th): σ = PR/2Th In the left ventricle, geometry is much more complex, and several components of stress exist within the wall (Fig. 4-6) . Of these, meridional and circumferential TABLE 4-2 -- Aspects of Ventricular Function Pump performance The pumping activity of the left ventricle that results in the delivery of oxygenated blood to the tissues. Stroke volume and stroke work are
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 7
parameters of pump performance Ventricular function Left ventricular performance assessed relative to end-diastolic fiber length (or related parameter) Myocardial contractility A basic property of the myocardium that reflects its active state, rather than loading conditions Contractile function A descriptor of ventricular performance or function that is affected by inotropic state, fiber length, or load stresses have most commonly been used in the analysis of LV mechanics. The meridional stress vector is oriented in the longitudinal or apex-to-base direction and represents the component of the load resisting long-axis shortening; circumferential stress is oriented along the equator, perpendicular to the long axis (see Fig. 4-6) and represents the component of the load resisting minor-axis shortening. Meridional stress (σm ) can be calculated as
σm = P · LVID / [4 · Th(1 + LVID/Th)] where P is pressure (mm Hg), Th is wall thickness, and LVID is cavity dimension.[38] This stress parameter does not require measurement of the long axis of the LV cavity. Circumferential stress (σc ) can be calculated as σc = P · a2 [1 + (b2 /r2 )]/(b2 − a2 ) where P is end-systolic pressure (mm Hg), a is the internal (endocardial) radius, b is the external (epicardial) radius, and r is the midwall radius.[39] Other approaches to the calculation of circumferential stress, using minorand major-axis dimensions, have been evaluated.[40] Formulas for calculation of meridional and circumferential stress using 2D echocardiographic data are as follows:[41] σm = 1.33P Am /Ac · 103 kdyn/cm2
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 7
where At is the short-axis area subtended by the LV epicardium and right
side of the septum, Ac is the cavity (endocardial) area, and Am = At − Ac or
myocardial area, and L is the LV cavity length, obtained from the apical four-chamber view. Two-dimensional and M-mode methods yield somewhat different results, with M-mode-derived σm being higher than 2D-
derived values, even in normal subjects. In spherical ventricles, σm by any method tends to overestimate afterload.[42]
The determination of wall stress requires assessment of LV pressure. Invasively determined values may be combined with echocardiographic dimensions, but they are often not available or simultaneously obtained. Three methods have been proposed for using noninvasive recordings to ascertain LV systolic pressures; LV diastolic 69
Figure 4-6 Schematic of the left ventricle (LV) (represented as a truncated ellipsoid) illustrating the major stress vectors. Meridional stress (σm ) is the force acting along the long axis of the LV; meridional stress opposes long-axis shortening. Circumferential stress (σc ) is the force acting in the equatorial direction; circumferential stress opposes circumferential fiber shortening, and circumferentially oriented fibers are located in the midwall of the left ventricle. (From Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:375.)
pressures (and therefore diastolic stress) cannot be reliably determined noninvasively. Although these methods assume that there is no LV outflow gradient, the first and easiest method assumes that end-systolic LV pressure can be approximated by peak arterial pressure.[38] Thus, cuff systolic blood pressure is substituted for LV end-systolic pressure. The second method involves calibration of an externally recorded pulse recording using cuff systolic and diastolic pressures, with calculation of arterial pressures at the dicrotic notch.[43] The third involves the substitution of mean arterial pressure, derived from cuff recording, for end-systolic pressure, given the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 7
close correlation between these two values, as shown by Rozich.[44] Because wall stress parameters incorporate appropriate size normalization, they allow comparison among the mechanical properties of different hearts. End-systolic wall stresses, calculated using end-systolic pressures (or the surrogates discussed earlier) and dimensions, are taken as indices of LV afterload, whereas end-diastolic wall stress, calculated using end-diastolic pressure and dimension, is a measure of LV preload. Preload is the force (i.e., load) acting to stretch the resting myofibril. Preload is commonly estimated as the LV end-diastolic pressure, diameter, or volume, but to be more precise, this force should be normalized for each unit cross-sectional area of muscle and expressed as end-diastolic wall stress. In this manner, LV preload is analogous to the preload on a strip of isolated cardiac muscle in a myograph. This force, which acts to stretch the myocardium, is resisted by the stiffness of the muscle. Thus, the extent to which the myocardial fiber is stretched depends on an interaction between preload and muscle stiffness. [45] Because preload influences initial fiber length, it affects LV systolic performance. This phenomenon, which operates on a beat-to-beat basis, is generally referred to as Starling's law of the heart or the Frank-Starling mechanism. The preload reserve of the ventricle depends on the baseline hemodynamic conditions and the stiffness of the myocardium. Thus, in the upright posture, normal human subjects exhibit a substantial preload reserve, whereas in the recumbent posture they may exhibit a minimal preload reserve. The difference in preload reserve is related to difference in the baseline end-diastolic volume, which is lower in the upright posture than it is when the subject is recumbent, owing to the differences in venous return. This fact should be kept in mind when interpreting exercise studies; the end-diastolic volume of the normal left ventricle generally increases during upright exercise, but it may not during recumbent exercise. Moreover, the ability to recruit the Frank-Starling mechanism may also be limited in hypertrophied ventricles that have abnormal ventricular compliance characteristics. Thus, in patients with aortic stenosis or hypertensive heart disease, there may be little or no increment in LV end-diastolic volume during exercise, and consequently the EF may not increase normally.[46] [47] [48] Such limited preload reserve occurs as a result of a steep diastolic pressure-volume relation in which large changes in filling pressure cause only small changes in volume.[49] This mechanism may even underlie marginal LV function in the basal state.[45]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 7
Despite a low EF, many dilated hearts (particularly those with compensated mitral or aortic regurgitation) generate a normal or high stroke volume. In this instance, although the Frank-Starling mechanism may be a contributing factor, the large stroke volume is primarily a function of the large enddiastolic volume. In other words, the presence of a large LV chamber does not necessarily indicate use of preload reserve at the fiber level. Many such hearts retain the ability to use preload reserve to augment stroke volume. By contrast, in end-stage heart failure, preload reserve may be exhausted (Fig. 4-7) . Afterload can be thought of as the force (i.e., stress) developed by the myocardium after the onset of contraction. As described by the Laplace relation, afterload (systolic wall stress) is directly related to LV systolic pressure and radius, and inversely related to wall thickness. Afterload varies with time, and thus it can be calculated at the instant of aortic valve opening, at the end of ejection, or at any instant throughout systole. Whereas LV systolic pressure and systemic vascular resistance can affect afterload, neither of these should be considered the equivalent of afterload. [50] [51] [52] Likewise, aortic input impedance influences systolic pressure and stress, but impedance is not the equivalent of afterload.[53] In aortic stenosis, the LV systolic pressure may exceed 250 mm Hg, but if there is an appropriate increase in LV wall thickness, the force borne by each unit of heart muscle might remain near normal (i.e., afterload is normal). [51] [52] , [54] On the other hand, an acute increase in systolic pressure or chamber size can result in an increased afterload.[55] By virtue of the inverse relation between load and shortening, an acute increase in afterload generally causes a decrease in shortening, and vice versa (see Fig. 4-7) . Contractility can be defined as the quality of cardiac muscle that determines performance independent of loading conditions. Contractility is easiest to study and define in isolated heart muscles when loading conditions are held constant. For example, if resting length is held constant, the addition of digitalis or norepinephrine to an isolated muscle preparation results in an increase in the 70
Figure 4-7 Left, The relation between left ventricular afterload and fiber shortening. Two coordinates of afterload are shown on a normal curve. If preload is constant, an acute increase in afterload will cause a decrease in
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 7
shortening. During acute interventions in a clinical setting, the relation between aortic pressure and stroke volume is similar to this schematic afterload-shortening curve. A failing ventricle exhibits a depressed curve with reduced shortening; thus, the ejection fraction and stroke volume can be depressed despite a normal afterload. Middle and right, Afterload-shortening relations in moderate and severe left ventricular dysfunction. In moderate dysfunction (middle), shortening in the basal state (A) is depressed; if some preload reserve is present, mild pressor stress does not substantially reduce shortening (B); more marked pressor stress will depress shortening (C). In severe dysfunction (right), inotropic state is markedly depressed and preload reserve is exhausted; under these circumstances, any pressor stress will cause a decrease in shortening. (From Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:377–378.)
extent and velocity of force development and shortening; such increased performance under constant loading conditions reflects an augmented inotropic state (i.e., increased contractility). In many cardiac diseases, abnormal LV pump function may be caused by disordered loading conditions, depression of contractility, or both. For this reason, it may be difficult to determine the exact cause of decreased fiber shortening. Accordingly, there has been considerable interest in the development of a sensitive index of contractility that is not affected by changes in loading conditions.[56] [57] Unfortunately, there is no completely load-independent index of basal contractile state. Thus, directional changes in contractility (during acute hemodynamic interventions) are relatively easy to demonstrate, but it is not possible to define a basal level of contractility in patients with chronic heart disease.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/34.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 14
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Assessment of Left Ventricular Mass, Volume, and Geometry Remodeling of the left ventricle in valvular heart disease, heart failure, and hypertensive heart disease is characterized by changes in LV mass and geometry. Descriptors of LV geometry include the relative wall thickness, short axis/long axis ratio, and volume/mass ratio. These descriptors are easily obtained by M-mode and 2D echocardiography. As suggested earlier, alterations in LV geometry have been used to assist risk stratification in a variety of diseases and to describe more completely remodeling changes effected by valve replacement. In patients with idiopathic dilated cardiomyopathy, for example, a poorer survival is associated with larger short-axis dimension and a greater ratio of short/long axes (i.e., a more spherical LV geometry).[58] The relative wall thickness, when used to estimate the "adequacy" of LV hypertrophy in patients with idiopathic dilated cardiomyopathy, also predicts the increase in contractility in response to dobutamine infusion[59] cardiomyopathy patients with a diminution in relative wall thickness appear to have an attenuated contractile response to dobutamine infusion. In the following section, the methods used to calculate LV mass and describe LV geometry are reviewed. M-mode Echocardiography Mass
Whereas newer and more costly tomographic methods, such as ultrafast computed tomography (CT) and magnetic resonance imaging (MRI), permit more precise quantitation, echocardiography remains the most commonly used technique for estimating LV mass and geometry. M-mode echocardiography is universally available and relatively low cost, and there is a considerable body of evidence supporting its accuracy in LV mass quantitation.[60] [61] [62] [63] Quantitation of mass (see also Chapter 32) is based on the geometric assumption that the ventricle is a prolate ellipsoid with a
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 14
2:1 long axis/short axis ratio.[60] [61] [62] [63] [64] [65] In practical terms, LV mass estimates are most accurate in ventricles with normal shape,[64] [65] specifically, a long axis/short axis ratio that approximates 2:1. It is assumed, of course, that minor axis dimensions are measured in a region free of wall motion abnormalities. This assumption is invalidated in ischemic heart disease with focal wall motion abnormality or in right ventricular overload. Estimates of myocardial mass and volume are derived from LV minor axis dimensions obtained with the transducer in the parasternal position (Fig. 4-8) . Under 2D echocardiographic guidance, the ultrasound beam is aligned so that it is perpendicular to the interventricular septum and 71
Figure 4-8 Schematic of an M-mode echocardiogram obtained using two-dimensional echocardiographic guidance. Measurements are made coincident with the Q wave of the simultaneous electrocardiogram. LVIDd, left ventricular internal dimensions in diastole; LVIDs, left ventricular internal dimensions in systole; PWTd, posterior wall thickness in diastole; PWTs, posterior wall thickness in systole; STd, ventricular septal thickness in diastole; STs, ventricular septal thickness in systole. (From Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:381.)
posterior wall at a level slightly below the mitral leaflet tips; the transducer is then rotated to obtain a short-axis view. This approach maximizes the LV cavity dimension and ensures that proper beam orientation with respect to the papillary muscles is obtained. LV mass is estimated from measurements of septal and posterior wall thickness and LV cavity dimensions at enddiastole using the anatomically validated cube formula[60] [61] [62] [63] [64] [65] LV mass = 0.8{1.04(STd + LVIDd + PWTd )3 − LVIDd 3 } + 0.6 g where STd is the diastolic septal thickness, LVIDd is the diastolic LV cavity dimension, PWTd is the diastolic posterior wall thickness, and 1.04 is the
specific gravity of myocardium. The measurements are made using the American Society of Echocardiography standard technique.[60] As shown by Devereux et al,[61] LV mass estimates made with American Society of Echocardiography measurements overestimate true anatomic LV weights by 20%, necessitating a correction factor of 0.8.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 14
Volume
A simple estimate of LV volume may be obtained from the minor-axis dimension, derived by M-mode echocardiography as V = LVID3 The geometric assumptions are similar to those used for LV mass calculation. However, in the dilated, spherical left ventricle encountered in long-standing valvular regurgitation or dilated cardiomyopathy, the ratio of length to minor-axis dimension decreases, leading to significant overestimation of LV volumes by this simple method. Teichholz et al[66] derived a formula that attempts to correct for this problem: Vd = [7/(2.4 + LVIDd )] · LVIDd 3 LV volumes derived with this formula correlate well with single-plane angiographic estimates.[64] The Teichholz method produces the most accurate volume estimates of any of the M-mode formulas.[67] Because Mmode echocardiography provides minor-axis dimensions of the left ventricle in systole and diastole, the Teichholz method may be used to compute LV volumes at end-systole and end-diastole, and thus to derive stroke volume and cardiac output. A compelling advantage of this method is that LV volume can be determined rapidly from easily obtained M-mode measurements. Relative Wall Thickness
M-mode estimates of myocardial mass and volume are derived from LV minor-axis dimensions obtained with the transducer in the parasternal position (see Fig. 4-8) . These same measurements are used to describe LV geometry. Although the amount of LV mass is an important 72
predictor of subsequent cardiac events in hypertensive disease, the geometry and pattern of LV hypertrophy also provide insight into the pathophysiology of hypertensive hypertrophy[68] and may confer prognostic information. [29] [30] [31] The most commonly used index of the pattern of hypertrophy is the relative wall thickness (RWT),[32] [68] which is calculated as
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 14
RWT ± 2 · PWT/LVID where PWT is the posterior wall thickness and LVID is the LV internal dimension, respectively; relative wall thickness may be measured in diastole or systole. Relative wall thickness also has been expressed as h/R, where h is wall thickness and R is cavity radius. Ford[69] and others[52] [54] have shown that in the normal or compensated ventricle, the relative wall thickness increases in direct proportion to elevations in systolic pressure (Fig. 4-9) . Assuming that there is not a substantial shape change as the ventricle enlarges (i.e., during normal growth), the relation is independent of absolute chamber size. [52] It is also assumed that the magnitude and transmural distribution of stresses are the same in normal ventricles of different size. Systolic dysfunction with dilation is usually associated with a lower relative wall thickness; in contrast, chronic pressure overload produces an increment in wall thickness with little change in the chamber radius (a high relative wall thickness).[70] In untreated hypertensive patients, LV mass and relative wall thickness determinations may be used to subdivide Figure 4-9 Relationship between relative wall thickness (RWT, equivalent to the ratio of thickness to radius) and level of systolic pressure in patients with aortic stenosis (black circles). In normal hearts (open diamonds), RWT increases in direct proportion to the level of systolic pressure. Individuals with a higher thickness-to-radius ratio than predicted by the level of pressure are considered to have inappropriate (or excessive) hypertrophy; by contrast, individuals whose thickness-to-radius ratio is less than that predicted by the level of pressure have inadequate hypertrophy. In normal hearts the relationship between peak pressure (P) and RWT, as defined by Ford,[69] is RWT = 0.0027P.
the population into four general categories (Fig. 4-10) : 1. Concentric hypertrophy (elevations in both LV mass and relative wall thickness) 2. Eccentric hypertrophy (elevation in LV mass with normal relative wall thickness) 3. Concentric remodeling (normal mass but abnormally high relative wall thickness) 4. Normal LV mass and relative wall thickness
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 14
In a population of untreated hypertensive patients, the majority had normal LV mass and normal relative wall thickness; concentric hypertrophy was the least common abnormal pattern observed. [68] What is the clinical relevance of the mass and geometry subcategories? Patients with concentric hypertrophy have a relatively high incidence of adverse cardiovascular and noncardiovascular events compared with patients with eccentric hypertrophy.[30] [31] [32] In addition, concentric geometry, even without hypertrophy, appears to be associated with adverse consequences during follow-up (see Table 4-1) , although not all studies have confirmed that the incremental risk is independent of LV mass. [71] Thus, in hypertensive disease, as noted earlier, incremental information regarding risk for both cardiovascular and noncardiovascular events is provided by assessing geometry as well as LV mass. The relative wall thickness may provide insight into the appropriateness of hypertrophy. There is occasionally more muscle mass than would be required for the observed pressure; thus, a very high relative wall thickness, such as is encountered in hypertrophic cardiomyopathies, "hypertensive hypertrophic cardiomyopathy of the elderly,"[72] [73] [74] [75] uncommonly in hypertension, and not infrequently in aortic stenosis,[70] indicates excessive or inappropriate LV hypertrophy. In our experience, relative wall thickness values greater than 0.8 are uncommon in aortic stenosis, but when present, they appear to represent inappropriate hypertrophy. Indeed, values exceeding 0.8 predict a systolic pressure in excess of 300 mm Hg, a pressure rarely seen, even in adults with aortic stenosis[70] (see Fig. 4-9) . Extreme concentric hypertrophy, with exceedingly high values for relative wall thickness, has been described in elderly patients undergoing aortic valve replacement for aortic stenosis.[25] The interaction among shape, load, and function is complex and important, because each one may influence the others. A decompensated heart clearly demonstrates abnormalities of all three—low relative wall thickness, high afterload, and reduced function—yet it is not possible to state which abnormality is primary. Does the ventricle dilate, thereby raising afterload and reducing pump performance, or is shortening impaired first, leading to dilation, which then raises afterload? Human studies shed little light because of the lengthy time course of disease and other confounding factors; animal studies suggest that all three events may occur in concert.[76] Two-Dimensional Echocardiography Two-dimensional echocardiography permits acquisition of data with
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 14
excellent spatial orientation, because the left 73
Figure 4-10 Left ventricular (LV) volume, mass, and geometry, stress, and systolic shortening in various cardiac disorders. Different cardiac disorders are classified with respect to LV mass, volume, relative wall thickness (RWT), and volume/mass (V/M) ratio, as well as stress and shortening. (Redrawn from Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:385.)
ventricle can be sampled in real time at multiple levels. In many laboratories, therefore, 2D echocardiography is the principal noninvasive means for quantitation of LV volume as well as for the assessment of global and regional systolic function. LV mass and volume quantitation by 2D echocardiography requires high-quality images and true long- and short-axis images of the left ventricle. A variety of geometric models is used to approximate the shape of the left ventricle and to compute LV volumes, including the prolate ellipse model, the hemiellipse model, and others that represent a combination of geometric shapes. Detailed review of the geometric principles underlying these volumes for formulas may be found elsewhere.[64] [65] [77] This chapter emphasizes the applications most suited for clinical use. Mass
Theoretically, 2D echocardiographic assessment of LV mass can improve on the limitations of M-mode methods; mean wall thickness can be backcalculated from planimetered short-axis myocardial area, which helps avoid reliance on single-dimensional determinations. One of the most practical 2D methods for mass calculation, the area-length method, approximates the left ventricle as a cylinder-hemiellipsoid; volume is calculated for both the inner and outer "shells" (the LV cavity and total myocardial area, respectively), as shown schematically in Figure 4-11 : V = 5/6 A × L where A is planimetered short-axis area obtained at the high papillary muscle level and L is the LV length obtained from the apical four-chamber view; area and length measurements are made at end-diastole. In this way, total LV and internal (LV cavity) volume are determined; myocardial
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 14
volume is the difference between the inner and outer shells. [65] [77] [78] [79] Myocardial volume is then multiplied by the specific gravity of myocardium (1.04 g/cc) to compute myocardial mass. The model has been validated by comparing echocardiographic and anatomic LV mass in 21 patients who underwent 2D echocardiographic studies shortly before death [79] there was an excellent correlation between anatomic and echocardiographic mass (r = 0.93 and SEE = 31 g). It is important to note that phantom-generated regression equations were used to correct clinical mass measurements for each 2D echocardiographic machine. Although more complicated 2D echocardiographic methods for mass determination have been associated with greater accuracy, the cylinder-hemiellipsoid area-length method represents a relatively simple and practical approach that yields acceptable results.[64] [65] Volume
As noted earlier, a variety of geometric approaches is described for the quantitation of LV volume from 2D 74
Figure 4-11 Schematic illustrating the technique used to calculate left ventricular (LV) mass with the area-length method. Endocardial and epicardial borders are traced (and papillary muscles excluded). Mean wall thickness (t) is back-calculated from the LV cavity area (A2 ) and total area (A1 ), and minor axis radius (b). The sum a + d is equivalent to the diastolic LV cavity length, which is measured from the apical four-chamber view. (Adapted from Schiller N, Shah P, Crawford M, et al: J Am Soc Echocardiogr 1989;2:358–367. From Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:389.)
echocardiography. There are theoretical advantages for use of the Simpson's rule algorithm, and this approach is preferable when ventricular shape is distorted, such as with an apical aneurysm. The Simpson's rule approach, also known as the method of discs, is predicated on the fact that the volume of the whole left ventricle (or of any object) may be computed as the sum of individual "slice" volumes. In general, the accuracy of the measurement varies directly with the number of slices:
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 14
V is total volume (cavity or myocardial), A is planimetered area, and T is slice thickness. Myocardial volume is then multiplied by the specific gravity of myocardium to estimate myocardial mass. It is best to compute LV volume from two orthogonal apical views with the LV length divided equally along that length[74] [75] [76] [77] [78] [79] apical four- and two-chamber views at end-diastole should be recorded to maximize ventricular length. The use of the cylinder-hemiellipsoid (area-length) method for calculating the volume component represents a reasonable alternative to the method of discs. The method described by Tortoledo et al[80] allows for the computation of end-diastolic volume from 2D-derived minor- and majoraxis dimension and has been shown to correlate closely with single-plane angiographic volumes: EDV = (Dmax × Lmax × 3.42) − 6.44 where Dmax and Lmax are maximal minor- and major-axis dimensions
derived from apical views.
In general, LV volumes derived from 2D echocardiographic measurements are smaller than those obtained by contrast angiography.[64] [65] There are many explanations for these findings, including foreshortening of the maximal length of the left ventricle on 2D echocardiography; differences in measurement of the LV long axis; and the fact that angiographic contrast material fills intermyocardial interstices, contributing to overall LV cavity volume, whereas echocardiography does not account for this volume.[64] Geometry
Compared with M-mode echocardiography, 2D echocardiography offers improved spatial orientation, because the left ventricle can be sampled in real time at multiple levels. Accordingly, 2D echocardiography may be used to quantify the LV mass and chamber volumes of abnormally shaped ventricles, and, because measurements of LV length are possible, this technique provides more extensive description of LV geometry. Estimates of both the short axis/long axis ratio and the volume/mass ratio[81] [82] [83] [84] are possible with 2D echocardiography. In patients with normal LV mass and function, the short axis/long axis ratio ranges from 0.45 to 0.62.[82] [83]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 14
In untreated hypertensive patients with normal LV systolic function, the short axis/long axis ratios range from 0.52 ± 0.04 in patients with concentric remodeling to 0.63 ± 0.03 in patients with eccentric hypertrophy.[68] The short axis/long axis ratio also provides information regarding ventricular compensation in valvular heart disease. As in patients with dilated cardiomyopathy, in whom the ventricle becomes more spherical, patients with poorly compensated aortic stenosis and regurgitation (those with low EFs) tend to have higher short axis/long axis ratios. [84] A high ratio in turn alters the relationship of meridional to circumferential stresses, a change in the distribution of afterload that may affect overall pump performance[84] (see Fig. 4-10) . [84]
The end-diastolic volume/mass ratio in normal men and women, as defined by 2D echocardiography, is approximately 0.8.[83] It has been traditionally assumed that the ratio of LV volume to mass is relatively constant from 75
the most basal to the most apical slices of the left ventricle. A study using the technique of ultrafast CT, which can provide approximately eight tomographic slices through the left ventricle, showed that in normal subjects, the volume/mass ratio decreased from approximately 0.8 at the most basal slice, a finding consistent with results of 2D echocardiography, to approximately 0.25 at the most apical slice. LV mass exceeds LV volume at each slice location.[85] It is important to emphasize that 2D echocardiographic methods have limitations that militate against their routine use for quantitation in the clinical setting[64] [65] (Table 4-3) . M-mode echocardiography samples at approximately 1000 frames per second, whereas the frame rate for 2D echocardiography is orders of magnitude less: 30 to 60 frames per second under optimal conditions. There is considerable image degradation when stop frames are used, making precise endocardial definition problematic. Near-field artifact and poor lateral resolution make it difficult to reliably identify endocardium around the entire ventricular perimeter. Apical views often do not yield images of sufficient quality for manual tracing.[86] Computations tend to be tedious. It is likely that digital technology, which has permitted the growth of stress echocardiography, will be routinely used for LV volume quantitation; at present, however, it appears that most 2D quantitation performed clinically is still subjective.[86] [87]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 14
In view of the limitations discussed earlier, there is considerable interest in the development of online, beat-to-beat volumetric quantitation. One potential solution is the technique of automated boundary detection, which uses integrated backscatter to define a border between echocardiographic picture elements (pixels) assigned to myocardium or LV cavity.[88] [89] [90] Thus, the area of the LV cavity can be displayed for each frame, plotted with respect to time, and the fractional area change computed; the technique may be applied to images obtained from either parasternal or apical windows. Several validation studies have been performed with this technique[88] [89] [90] and have shown an excellent correlation between online LV cavity areas and offline manual planimetry of the corresponding 2D echocardiographic images (Fig. 4-12) . Further software development now permits online estimation of beat-to-beat LV volumes (using the arealength or TABLE 4-3 -- Limitations of Ultrasound Methods for Mass and Volume Quantitation General All methods require high-quality images with good endocardial definition Most methods require geometric assumptions about left ventricular shape and are applicable only to normally shaped hearts M-mode echocardiography Small errors in measurement may lead to large errors in mass/volume determinations May be insensitive to small changes in mass (20–40 g) observed in response to antihypertensive treatment Two-dimensional echocardiography Limited frame rate, making timing of cardiac events difficult Considerable degradation when images are stop-framed Apical images may foreshorten true left ventricular length Tedious, labor-intensive computations Simpson's rule methods), dV/dt, time to peak positive dV/dt, and time to peak negative dV/dt. Software upgrades, such as beat selection and signal averaging, may enhance the application of the automated border detection system for clinical use, which is currently somewhat limited by a significant percentage of technically inadequate studies[86] and other
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 14
technical problems. Assuming these problems will be solved, automated border detection has particular promise for online quantitation of LV volumes obtained by intraoperative transesophageal echocardiography, in view of the generally excellent image quality with this technique. Other automated edge detection systems are in development, and this remains an area of active investigation. Another area of active research is that of three-dimensional (3D) echocardiography (see Chapter 10) . This technique promises to provide the most accurate ultrasound determination of LV volume, mass, and EF, largely because the need for geometric assumptions and on-axis views will be eliminated.[91] [92] [93] [94] Alternative Methods for Quantitation of Left Ventricular Structure and Function In addition to cardiac ultrasound, the clinician may use other noninvasive and invasive techniques to measure LV size and function. A brief review of some of the more commonly used techniques is therefore appropriate. Doppler Echocardiography
Routine Doppler measurements of flow velocity may be combined with echocardiographic dimensional data to determine stroke volume and cardiac output. [94] [95] [96] This technique is known as the time velocity integral (TVI) method. The appeal of this method is that, unlike M-mode and 2D echocardiographic measurements, TVI measurements do not require geometric assumptions about cardiac shape. To compute stroke volume using the TVI method, an integral of the systolic pulsed wave flow envelope in the aortic outflow tract is computed (Fig. 413) . To obtain this velocity spectrum, the transducer is placed in the apical position with the sample volume positioned at the level of the aortic valve annulus. Although the TVI may be obtained in other locations, such as the pulmonary artery or LV inflow, accuracy seems to be best with measurements made in the proximal ascending aorta.[65] The cross-sectional linear dimension of the proximal ascending aorta is obtained in the same approximate location that the pulsed or continuous wave Doppler velocity spectrum is recorded, using the parasternal long-axis window (see Fig. 413) . Stroke volume (SV) is then the product of the TVI and cross-sectional area of the aortic annulus, which is assumed to be circular:
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 14
CSA = π(D/22 ) SV = CSA · TVI
76
Figure 4-12 Technique of automated boundary detection and its application to the study of cardiac volumes and ejection fraction (EF) in clinical practice. Top, A parasternal short-axis image with corresponding enddiastolic and end-systolic areas (EDA and ESA, respectively); the fractional area change for each beat is also displayed below the two-dimensional image. Bottom, In an apical four-chamber view, the corresponding beat-to-beat volume display is shown. From these measurements, the EF can be computed beat to beat. End-diastolic and end-systolic volumes (EDV and ESV, respectively) are given in milliliters.
where CSA is the cross-sectional area of the aortic annulus, D is the linear dimension of the annulus, and TVI is the time velocity integral. Stroke volume and cardiac output obtained by the TVI method correlate well with results of concurrent thermodilution cardiac output determinations in patients who were without left-sided valvular regurgitation.[95] [96] The Doppler TVI method is highly dependent on accurate measurements of aortic annular diameter, because the CSA formula involves squaring the annular dimension; it is also assumed that the Doppler beam is oriented parallel to flow. This method can be particularly useful for following changes in a single patient—beat to beat, or over weeks to months. Doppler echocardiographic assessments of LV function do not depend on measurements of ventricular size (and thus avoid the attendant geometric assumptions and sources of error); they rely on information derived from flow velocities.[96] This information includes measurement of LV stroke volume, cardiac output, and peak flow velocity of aortic ejection, all of which, being ejection phase indices, are dependent on afterload. One approach to the noninvasive assessment of dP/dt has used the continuous wave profile of the mitral regurgitant flow.[97] [98] [99] As we have seen, stroke volume, and thereby cardiac output, may be calculated by measuring the area under the flow velocity contour and multiplying it by the cross-sectional
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 14
77
Figure 4-13 Calculation of cardiac output using the time velocity integral (TVI) method. The continuous wave Doppler-derived TVI (also called velocity time integral [VTI]) is displayed. The cross-sectional area is 3.14 cm2 (π times the square of the annular radius, which is 1 cm2 in this instance) and the TVI is 24.7 cm by planimetry. The stroke volume is 78 cc per beat by equation, yielding a cardiac output of 4.3 L/min at the patient's heart rate of 55.
area of the annulus.[94] [95] Accuracy is dependent on recording velocity parallel to flow and, most importantly, on the aortic diameter measurement used to calculate the cross-sectional area. This method also requires that there be no significant aortic or mitral valve disease. Aortic acceleration and peak flow velocity are both reduced in cardiomyopathy,[94] but this has not received widespread clinical acceptance as a diagnostic tool. Magnetic Resonance Imaging
In many respects, MRI is the ideal method to quantitate LV mass and volume. It combines the attributes of ultrafast CT (noninvasive and permitting true tomographic imaging throughout the entire cardiac volume) with several unique advantages. MRI does not require contrast administration or ionizing radiation, and there is no limitation to image plane selection; thus, the heart may be imaged not only in the familiar contrast ventriculography views but also in the long- and short-axis planes used in standard transthoracic echocardiography. MRI usually provides images with excellent contrast between myocardium and the blood pool so that manual or even semiautomated computerized mass and volume quantitation is possible.[100] For these reasons, MRI has provided the most accurate noninvasive estimates of LV mass and volume to date,[101] even in ventricles distorted by myocardial infarction.[102] A more recent advance, gradient-echo magnetic resonance techniques, displays the heart in cine loop fashion at up to 64 frames per cardiac cycle; this technique can be used to quantitate EF and regional function and to estimate the severity of valvular regurgitation. [103] [104] [105] Although MRI can be used to estimate mass, volume, and EF,[36] [106] [107] ultrasound and radionuclide techniques are currently much more commonly used for this purpose. If technologic advances in MRI lead to shorter scan times and reduced scan costs and permit routine, accurate assessment of coronary anatomy, it is not hard to conceive that this technique will be
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 14
widely used to provide a comprehensive assessment of cardiac structure and function. At present, however, the use of MRI in adult clinical practice is usually confined to answering questions regarding anatomic abnormalities, such as disorders involving the aorta, the pericardium, congenital heart disease, cardiac masses, and RV dysplasia.[108]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/35.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 13
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Assessment of Left Ventricular Systolic Function As shown in Figure 4-5 , the major factors affecting LV systolic performance and function are preload, afterload, myocardial contractile (or inotropic) state, and heart rate. Nonuniform contraction can also be important; thus, regional variations in mechanical function, as occur in coronary heart disease or even with electronic ventricular pacing, can affect stroke volume. Only if synchronous contraction is present, heart rate is stable, and loading conditions are constant does a change in performance indicate a change in contractility. These traditional concepts relating preload, afterload, and contractility are generally considered in the assessment of an acute response to altered hemodynamic conditions. Thus, an isolated increase in preload is said to produce an increment in performance through the Frank-Starling mechanism, whereas an isolated increase in afterload is said to produce 78
TABLE 4-4 -- Clinical Methods Used to Evaluate Systolic Function Ejection fraction Fractional shortening at endocardium and midwall Stress-shortening relations Pressure-volume analysis a decrease in the stroke volume (or EF) by virtue of the inverse forceshortening relation. Unfortunately, in the intact heart, especially in patients with chronic heart disease, it is virtually impossible to produce an isolated change in preload or afterload. For example, nitrates are classified as vasodilators and agents that primarily affect preload, but the associated decrease in LV volume and arterial pressure leads to a reduction in
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 13
afterload. Likewise, a pure arterial vasodilator also reduces heart size (and preload) by augmenting the stroke volume. It is apparent, therefore, that preload and afterload are intimately related, and that it is an oversimplification to assume that isolated changes in preload or afterload occur in patients with chronic heart disease. Most interventions that produce an acute change in preload or afterload also result in a length-dependent change in intrinsic myocardial contractility, [109] which further complicates the assessment of global systolic function. Therefore, acute changes in preload produce changes in performance through the Frank-Starling mechanism and through this length-dependent activation. The importance of this phenomenon in the chronically enlarged or diseased heart is unknown. It is usually not difficult to detect an acute change in LV performance or contractile function, but it is harder to determine the major mechanism or mechanisms responsible for the change. Chronic changes in LV volume, mass, and geometry are even more difficult to interpret because such changes tend to limit our use of the traditional interrelationships of preload, afterload, and contractility. Indeed, there is no acceptable index of basal contractility that can be used in patients with chronic heart disease, nor can LV end-diastolic pressure or even absolute end-diastolic volume be used as a surrogate for fiber stretch in chronically diseased hearts. For these and other reasons, the evaluation of contractile function and the distinction between a compensated and a decompensated ventricle often rest on empiric observations coupled with analyses based on physiologic principles. In the following section the use and limitations of several clinically useful approaches to the evaluation of contractile function are discussed (Table 4-4) . Ejection Fraction The EF is perhaps the most widely used measure of LV systolic function. This parameter is defined as the change in LV volume (i.e., stroke volume) divided by the initial volume (i.e., end-diastolic volume): EF = (EDV − ESV)/EDV where EDV is end-diastolic volume and ESV is end-systolic volume; these may be obtained by either M-mode or 2D echocardiography. In addition, there are other published algorithms that use minor-axis dimensions and an estimate of long-axis shortening derived from 2D echocardiography to
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 13
derive EF directly.[110] The EF, representing volume strain, is appropriately normalized; it can be used as an index of systolic function that is independent of the size of the patient or the ventricle. The normal ventricle ejects more than half of its end-diastolic volume; the average EF, as determined by 2D echocardiography, varies from 63% to 69%.[81] In patients with coronary disease or idiopathic cardiomyopathy, it is generally conceded that values in the range of 40% to 50% are abnormal but of little clinical significance.[1] However, in patients with mitral regurgitation, an EF in this range may denote significant depression in contractile function.[111] Hemodynamic Determinants of the Ejection Fraction
Acute changes in LV loading conditions are known to exert a major influence on the EF. Thus, an acute increase in preload and/or a decrease in afterload results in a higher EF. By contrast, an acute decrease in preload and/or an increase in afterload reduces the EF. Under such circumstances, it can be difficult to decide whether a change in contractility has occurred. If, however, alterations in load are associated with a change in the EF that is opposite to the expected result, it is possible to conclude that a simultaneous change in contractility (i.e., inotropic state) also occurred. For example, an increased EF in the presence of increased afterload likely represents increased contractility, because an increase in afterload would normally be expected to cause a lower EF. Despite its load sensitivity, the EF can therefore provide useful information, even during acute hemodynamic interventions. In this regard, the concept of preload reserve is important. In patients with chronic heart disease, the EF can be an important index of contractile function, in part because of its sensitivity to increased afterload. As LV dysfunction develops and dilation occurs, afterload tends to increase, as dictated by the Laplace relationship, and the EF falls.[55] Such a decline in the EF can be useful in identifying LV dysfunction very early in the course of a disease; it does not, however, identify the underlying mechanism or mechanisms. Therefore, in patients with chronic heart disease, the EF must be interpreted with consideration of the magnitude and time course of changes in loading conditions that evolve during progression of the disease.[111] For example, very early in the course of aortic regurgitation, LV preload and afterload tend to be increased; these changes affect the EF in opposite directions, and it remains within the normal range. As the ventricle remodels and eccentric hypertrophy develops, the loads
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 13
normalize despite LV enlargement; if myocardial contractility is preserved, the EF remains normal. As the hemodynamic burden increases (or contractile dysfunction develops), the afterload increases and the EF decreases. Thus, 79
even a modest decline in the EF can be an important early marker of LV dysfunction. In decompensated aortic stenosis, LV systolic pressures increase in parallel with an increase in wall stress, as predicted by the Laplace relationship. As wall stress progressively rises, EF decreases. Carabello et al[21] have shown that patients with critical aortic stenosis, congestive heart failure, and decreased EF owing to high levels of wall stress ("afterload mismatch") may anticipate improvement in systolic function following afterload reduction associated with valve replacement[21] [111] [112] (Fig. 4-14) . In contrast, those patients whose reduction in EF is out of proportion to the high levels of wall stress are thought to have developed cardiomyopathic changes in addition to excess afterload; such patients generally do not experience functional improvement after valve replacement.[21] [112] This subgroup of patients may be identifiable by a low transvalvular gradient (usually less than 30 mm Hg) in association with severe stenosis of the aortic valve.[21] In the clinical setting, making the proper diagnosis can be challenging. Because the Gorlin equation is flow dependent, patients with primary LV dysfunction and coexistent (mild) calcific aortic stenosis can be difficult to distinguish from those with LV dysfunction caused by unrelieved severe aortic stenosis. Dobutamine echocardiography is increasingly used to help make this distinction and to assess prognosis.[113] Fractional Shortening and Related Indices The fractional change (percentage) in minor-axis dimension is a widely used index of systolic performance; fractional shortening is usually derived from M-mode echocardiographic tracings (see Fig. 4-8) . This measurement Figure 4-14 Relationship between ejection fraction (EF) and endsystolic stress in patients undergoing cardiac catheterization for critical aortic stenosis and severe congestive heart failure. All patients were free of significant coronary artery disease. Patients falling close to the regression line relating EF to stress (open circles) are thought to have
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 13
LV dysfunction owing to excessive wall stress (afterload). These patients experienced a gratifying functional recovery after aortic valve replacement. In contrast, the four subjects who fell below the regression line (dark circles) have depressed EF beyond that predicted by the level of afterload and are considered to have depressed contractility as well. These patients did not experience functional recovery after valve replacement. (Adapted from Carabello BA, Green LH, Grossman W, et al: Circulation 1980;62:42. From Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:416.)
is particularly useful because LV circumferential fiber shortening is responsible for most of the stroke volume. In this regard, fractional shortening is similar to the EF; in the absence of focal wall motion abnormalities, the two indices correlate closely, although the absolute values for fractional shortening are obviously less than that for EF. Fractional shortening, measured at the endocardium (FSendo [%]), is
calculated as
FSendo = 100 × (LVIDd − LVIDs )/(LVIDd ) Normal values for FSendo exceed 30%. As is the case with EF, FSendo is
influenced by factors in addition to contractile state and should be interpreted in the light of loading conditions; increases in preload and decreases in afterload increase fractional shortening.
A refinement of fractional shortening, the velocity of circumferential shortening (Vcf ) reflects the mean velocity of ventricular shortening at the level of the LV minor axis, and it is also calculated from M-mode echocardiographic dimensions: Vcf = FSendo /ET where ET is the ejection time derived either from the duration of aortic valve opening, from the period of aortic forward flow (pulsed or continuous wave Doppler), or from a carotid pulse tracing.[65] The Vcf is expressed in circumferences per second (the lower limit of normal is 1.1 c/sec); because Vcf measures the velocity rather than the extent of shortening, it is
theoretically a more sensitive index of contractility than FSendo and may be
an earlier marker of abnormality in chronic disease states. As with the EF and fractional shortening, this parameter is normalized for LV chamber size
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 13
and may be used to make comparisons between patients. Vcf has been
shown to be
80
relatively insensitive to acute changes in preload.[114] [115] However, it is also possible that this preload insensitivity may be a result of acute elevations in preload increasing heart size (and pressure) and thus increasing afterload. Thus, augmentation in afterload may offset the increased shortening caused by the increased preload. A further refinement in Vcf , the rate-corrected
Vcf ,[64] [65] [113] may be obtained by dividing Vcf by the square root of the
preceding RR interval. This index is designed to allow comparison between patients with differing heart rates. The incremental value of velocity of shortening methods (e.g., Vcf , rate-corrected Vcf ), compared with extent of shortening (e.g., fractional shortening) may be marginal.[116]
Standard M-mode measurements also may be used to estimate circumferential fractional shortening at the midwall (FSmw [%]), using the
same standard M-mode echocardiographic measurements. FSmw is
calculated using a modified two-shell cylindrical model.[37] This method assumes constant LV mass throughout the cardiac cycle and does not require the assumption that inner and outer wall thickening fractions are equal.[37] [117] [118] Most important, in contrast to FSendo , FSmw is not
influenced by LV geometry (relative wall thickness) and therefore has particular use in the evaluation of the hypertrophied heart with increased relative wall thickness (see Fig. 4-16) . Normal systolic function includes the excursion of the mitral annulus toward the relatively immobile apex; thus, the long axis of the left ventricle shortens during systole. An assessment of the longitudinal (or long-axis) shortening of the left ventricle can be made using M-mode measurements under 2D echocardiographic guidance.[119] [120] Using the apical window, the transducer is oriented to maximize apical endocardial to mitral annular distance. M-mode tracings are made with the cursor directed through the lateral aspects of the mitral annulus; recordings of multiple cardiac cycles are made on strip chart paper,[118] [120] and mitral annular excursion is normalized for initial diastolic length. Several investigators have used mitral annular excursion and long-axis
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 13
shortening as a descriptor of ventricular systolic function. Keren and LeJemtel [119] showed that the principal systolic mitral annular excursion toward the apex coincides with the systolic component of pulmonary venous flow; this systolic phase of mitral annular motion is markedly attenuated in patients with dilated cardiomyopathy. Jones and Gibson[120] showed that, in the normal left ventricle, mitral annular excursion toward the apex precedes circumferential shortening, leading to a more spherical LV shape early in systole.[120] These investigators also showed that mitral annular descent was reduced in patients with mitral disease who had undergone valve replacement.[120] In patients with "compensated" hypertensive heart disease, that is, LV hypertrophy and normal EF, longaxis shortening is depressed compared with normal controls.[118] Similar findings have been reported using the technique of MRI tagging, as described later.[121] Other ultrasound techniques have been employed in recent years to investigate LV systolic and diastolic function. Doppler tissue imaging applies a modification of pulsed Doppler methods to the assessment of myocardial systolic and diastolic motion.[122] [123] In this way, the velocity of myocardial tissue or of the mitral annulus, and not just the total excursion, may be measured. The velocity of the diastolic mitral annular motion has been applied to the study of LV diastolic function (see Chapter 6) .[122] [123] Nagueh et al[123] have demonstrated that mitral annular velocity information, when coupled with more traditional mitral inflow velocity data, can be used to reliably predict diastolic pressure. Similarly, more qualitative assessment of ventricular function can be obtained using color Doppler imaging.[124] Stress-Shortening Relations On the basis of extensive experimental and clinical experience, the myocardial force-velocity relation provides a framework for evaluating the contractile state and function of the left ventricle. A most important advantage of assessing function with a stress-shortening analysis is that it avoids afterload dependency, the major limitation of the EF alone. Unfortunately, end-diastolic fiber length (or the degree to which the resting fiber is stretched) is difficult if not impossible to measure; LV end-diastolic pressure or volume or even wall stress fails to provide an absolute measure of fiber length. For this reason, length is generally omitted and the simpler force-velocity or stress-shortening relation is used as a substitute for the force-length-velocity relation. Both systolic stress (the force per unit cross-sectional area of myocardium)
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 13
and shortening (fractional change in length or volume) are appropriately normalized and allow accurate comparisons among hearts of different sizes. [125] Therefore, contractile function in pressure overload hypertrophy, volume overload hypertrophy, and dilated as well as hypertrophic cardiomyopathies may be assessed within the framework of the stressshortening relation. A major limitation of the simple stress-shortening analysis is the assumption that differences in resting length do not substantially influence the stress-shortening relation. In this regard, a distinction must be made between acute interventions and chronic steady-state conditions. Changes in fiber length and appropriate use of preload reserve certainly occur during acute or short-term hemodynamic interventions. However, under chronic conditions (e.g., chronic compensated volume overload), this may not be the case.[126] After the acute or subacute phase, when the compensatory remodeling process is complete and chronic changes in LV volume and mass are established, end-diastolic fiber length may not be substantially different from normal.[127] In pressure overload or concentric hypertrophy, end-diastolic sarcomere lengths may even be less than normal.[128] [129] In such hearts, high chamber stiffness apparently limits use of the preload reserve. It appears, therefore, that assumptions about chronic changes in fiber length are unwarranted. Midwall Stress-Shortening Analysis
The analysis of midwall stress-shortening relations may be superior to that of endocardial stress-shortening relations, especially for comparison of contractile state between 81
hearts differing in LV geometry ( Fig. 4-15 and Fig. 4-16 ). The first advantage of midwall measurements is that the (circumferential) stress vector and the shortening transient are oriented in the same direction, because circumferential fibers predominate in the midwall of the LV.[130] [131] Second, the values for midwall (but not endocardial) shortening are consonant with experimental data indicating that myocardial fibers shorten by approximately 15% to 20%. Circumferential midwall strain ranges from 9% ± 2% in the anesthetized, open chest dog (implanted markers[132] ) to 30% ± 7% in conscious humans (MRI tagging).[133] We believe that the experimental results represent an underestimate of strain, but MRI
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 13
techniques likely overestimate true myocardial shortening. All methods indicate that circumferential shortening at the endocardium exceeds that seen at the midwall. Third, significant differences in chamber radius or circumference may be caused by differences in LV relative wall thickness. [37] By contrast, midwall shortening is independent of relative wall thickness. We believe that studies designed to assess myocardial contractile function should ideally be based on midwall stress-shortening data, not on endocardial Figure 4-15 Left ventricular (LV) shortening in normal LV (top) and in concentric left ventricular hypertrophy (LVH) (bottom), illustrating the added insight into systolic function provided by midwall shortening. LV endocardial dimension (LVID), wall thickness (Th), relative wall thickness (RWT), and LV mass are measured in diastole (d). The systolic dimensions (s) are shown at right. The midwall circumference is indicated by the dotted line. Systolic shortening refers to the percent reduction in the circumference that occurs from diastole to systole. FS endo, the percent reduction of the endocardial circumference (dark inner circle) and FS mw, the percent reduction of the midwall circumference (dotted line), are in the normal range. However, concentric LVH (elevated RWTd and LV mass) is associated with an increased value for FS endo, but a diminution in FS mw, compared with normal LV, owing to the nonuniformity of systolic thickening. Myocardial fibers in the inner (subendocardial) layers contribute more to systolic thickening than those in the outer (epicardial) layers; this effect is exaggerated when concentric geometry is present.
shortening parameters, which may be contaminated by altered ventricular geometry. An example of the usefulness of a midwall stress-shortening analysis is shown in Figure 4-17 . The endocardial stress-shortening relation is normal in patients with pressure overload hypertrophy owing to aortic stenosis; thus, LV function is normal. By contrast, the midwall stress-shortening relation is abnormal in approximately one third of the patients, indicating a subtle depression of myocardial function in these individuals. Pressure-Volume Analysis By plotting LV pressure against volume throughout the entire cardiac cycle, a pressure-volume loop can be generated (Fig. 4-18) . The height of the loop is determined by systolic pressure, and its width is determined by stroke volume; thus, the area within the loop is a measure of stroke work. By definition, such loops incorporate end-diastolic and end-systolic volumes; thus, the stroke volume and the EF are displayed. The bottom
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 13
limb of the loop (i.e., the diastolic pressure-volume curve) 82
Figure 4-16 Endocardial and midwall stress-shortening relations in pressure overload hypertrophy. The top panel shows fractional shortening at the endocardium versus circumferential stress in a consecutive series of patients with severe, symptomatic aortic stenosis who were free of segmental wall motion abnormalities. All patients fall within the 95% confidence intervals of the stress-shortening relationship, suggesting normal contractile function. In contrast, the bottom panel shows midwall shortening versus circumferential stress in the same population. A substantial portion (approximately one third) of these patients demonstrates a diminution in contractility by the midwall analysis.
describes ventricular diastolic compliance. Therefore, the pressure-volume loop can provide a simple yet comprehensive description of ventricular pump function. [134] Such loops can be generated from a variety of techniques that provides ventricular volume data in conjunction with LV pressure. [135] [137] Online, beat-to-beat determinations of LV volumes with automated edge detection can be combined with LV pressure measurements to yield real-time pressure-volume loops, useful in both clinical and research settings[137] [138] [139] (Fig. 4-19) . Pressure-dimension loops derived from M-mode echocardiographic data are adequate surrogates for pressurevolume loops, and they provide the added advantage of simplicity and widespread availability. If only the systolic portion is of interest, calibrated carotid pulse tracings may be substituted for intraventricular pressure, and the data can be obtained entirely noninvasively.[43] By manipulating LV volume and/or arterial pressure, multiple coordinates of the maximal ratio of pressure to volume or dimension (which occurs near end-ejection) can be obtained; these coordinates exhibit a nearly linear direct relation. The slope of this relation (Emax ) is relatively insensitive to
acute changes in loading conditions. The relation shifts upward and to the left during positive inotropic interventions, and it shifts downward to the right when the ventricle is depressed; the slope of the relation generally increases with the former and decreases with the latter ( see Fig. 4-18 and Fig. 4-19 ).
This end-systolic index of contractility is sensitive to acute changes in contractility, but its reliability is diminished in chronically diseased hearts, especially dilated hearts. In large ventricles the end-systolic pressure-
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 13
volume curve can be displaced down and to the right (depressed Emax ), in
the absence of a depressed contractility. For this reason, Emax should be
normalized for heart size,[140] [141] [142] as illustrated in Figure 1-19 . In this example of chronic aortic regurgitation, there is modest LV enlargement, the end-systolic volume is less than 60 mL/m2 , the EF is normal, and the total stroke volume is high. Such data indicate that the ventricle is compensated, albeit larger than normal. However, the depressed slope of the end-systolic pressure-volume relation inappropriately suggests depressed contractility. These disparate conclusions can be reconciled if the effect of chamber dilation on Emax is considered.[140] [141] [142] Thus, if the slope is normalized for chamber size, it approximates that seen in the normal heart.
Recognizing this limitation, end-systolic stress-volume or stress-dimension relations should not be a major criterion for the diagnosis of chronic contractile dysfunction. Certainly, it is not useful as a measure of basal contractility and it has limited applicability in comparisons among normal and diseased hearts. The raw pressure-volume or stress-dimension data provide important diagnostic information and, with few exceptions, the simple measurement of the end-systolic volume or dimension identifies a depressed ventricle. An example of the usefulness of echocardiography pressure-dimension loops is shown in Figure 4-20 . This example illustrates the effect of mitral valve replacement on LV size and function in compensated and decompensated chronic mitral regurgitation. In compensated mitral regurgitation the chamber is enlarged but the end-systolic dimension is only 42 mm, systolic stress is minimally increased, and the fractional shortening is normal (35%). After valve replacement the stress-dimension loop returns to near normal. In decompensated mitral regurgitation the end-diastolic and end-systolic volumes are markedly increased and fractional shortening is low (26%). After mitral valve replacement there is persistent LV enlargement and a further decline in shortening. A similar analysis has been used in patients with aortic regurgitation.[143] (See also Chapter 18.)
83
Figure 4-17 Left ventricular pressure-volume (P-V) loops. The dashed
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 13
line indicates a normal ventricle. An acute decrease in contractile state is shown; the loop is displaced to the right, and the end-systolic P-V line shifts downward and to the right. The effect of an acute increase in contractile state is illustrated by the line on the left; the slope of the end-systolic P-V line is increased (the corresponding loop is not shown). (From Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:418.) Figure 4-18 Pressure-volume loops with inferior vena caval occlusion at baseline and with 3 µg/kg/min of dobutamine infusion in an intact canine model. Volume was assessed online with transesophageal echocardiographic border detection using a Simpson's rule algorithm. End-systolic elastance (Ees ), or the slope of the end-systolic P-V relation, increased with positive inotropic modulation, which is consistent with increased contractility. (Courtesy of Dr. John Gorcsan III.) Figure 4-19 LV pressure-volume loops and end-systolic pressure volume lines illustrate the effects of chronic aortic regurgitation on ventricular size and function. Moderate ventricular enlargement is present, ejection fraction (EF) is normal, and stroke volume (SV) is high. Such data are consistent with compensated aortic regurgitation. However, the slope of the end-systolic P-V relation (Emax ) is reduced. This apparent inconsistency may be resolved by considering the effect of chamber size on Emax . If the slope is normalized for chamber size (end-diastolic volume), the result indicates that Emax is similar in the two ventricles. (Adapted from Shen WF, Roubin G, Choong CYP, et al: Circulation 1985;71:31–38. From Aurigemma GP, Gaasch WH, Villegas B, Meyer TE: Curr Probl Cardiol 1995;20:420.)
84
Figure 4-20 Left ventricular (LV) stress-dimension loops in two cases of mitral regurgitation, before (Preop) and after (Post) mitral valve replacement. In the left panel the preoperative loop indicates compensated ventricular function; the end-diastolic dimension is 6.5 cm, the end-systolic dimension is 4.2 cm, systolic stress is minimally elevated, and fractional shortening is normal (35%). After valve replacement the end-diastolic dimension and end-systolic wall stress return to normal, but fractional shortening decreases (29%). In the right panel the preoperative loop indicates a decompensated ventricle; the end-diastolic and end-systolic dimensions are markedly increased (7.3 cm and 5.4 cm, respectively) and fractional shortening is low (26%). After valve replacement there is persistent LV enlargement and a further decline in fractional shortening. These examples illustrate the LV response to mitral valve replacement in
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 14
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
References 1. Gaasch WH: Diagnosis and treatment of heart failure based on LV systolic or
diastolic dysfunction. JAMA 1994;271:1276–1280. 2. Mock MB, Rindqvist I, Fisher LD, et al: Survival of medically treated patients in
the coronary artery surgery (CASS) registry. Circulation 1982;66:562–567. 3. Hammermeister KE, De Rouen TA, Dodge HT: Variables predictive of survival in
patients with coronary disease. Circulation 1979;59:421–430. 4. White HD, Norris RM, Brown MA, et al: Left ventricular end systolic volume as the
major determinant of survival after recovery from myocardial infarction. Circulation 1987;76:44–51. 5. Pfeffer MA, Braunwald E, Moye LA, et al: Effect of captopril on mortality and
morbidity in patients with left ventricular dysfunction after myocardial infarction: Results of the survival and ventricular enlargement trial. N Engl J Med 1992;327:669– 677. 6. The SOLVD Investigators: Effect of enalapril on survival in patients with reduced
left ventricular ejection fractions and congestive heart failure. N Engl J Med 1991;325:293–302. 7. Bestetti RB, Dalbo CMR, Freitas OC, et al: Non-invasive predictors of mortality for
patients with Chagas heart disease: A multivariate stepwise logistic regression study. Cardiology 1994;84:261–267. 8. Feild BJ, Baxley WA, Russell RO Jr, et al: Left ventricular function and
hypertrophy in cardiomyopathy with depressed ejection fraction. Circulation 1973;47:1022–1031. 9. Vasan RS, Larson MG, Benjamin EJ, et al: Congestive heart failure in subjects with
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 14
normal versus reduced left ventricular ejection fraction: Prevalence and mortality in a population-based cohort. 1999;33:1948–1955. 10. Gottdiener JS, Arnold AM, Aurigemma GP, et al: Predictors of congestive heart
failure in the elderly: The Cardiovascular Health Study. J Am Coll Cardiol 2000;35:1628–37. 85
11. Schuler G, Peterson KL, Johnson A, et al: Temporal response of left ventricular
performance to mitral valve surgery. Circulation 1979;59:1218–1231. 12. Borow KM, Green LH, Mann T, et al: End-systolic volume as a predictor of post-
operative left ventricular performance in volume overload from valvular regurgitation. Am J Med 1980;68:655–663. 13. Gaasch WH, Carroll JD, Levine HJ, et al: Chronic aortic regurgitation: Prognostic
value of left ventricular end-systolic dimension and end-diastolic radius/thickness ratio. J Am Coll Cardiol 1983;1:775–782. 14. Zile MR, Gaasch WH, Carroll JD, et al: Chronic mitral regurgitation: Predictive
value of preoperative echocardiographic indexes of left ventricular function and wall stress. J Am Coll Cardiol 1984;3:235–242. 15. Hoshino PK, Gaasch WH: When to intervene in chronic aortic regurgitation. Arch
Intern Med 1986;146:349–352. 16. Bonow RO, Epstein SE: Is preoperative left ventricular function predictive of
survival and functional results after aortic valve replacement for chronic aortic regurgitation? J Am Coll Cardiol 1987;10:713–716. 17. Carabello BA, Usher BW, Hendrix GH, et al: Predictors of outcome for aortic
valve replacement in patients with aortic regurgitation and left ventricular dysfunction: A change in the measuring stick. J Am Coll Cardiol 1987;10:991–997. 18. Crawford MH, Souchek J, Oprian CA, et al: Determinants of survival and left
ventricular performance after mitral valve replacement. Circulation 1990;81:1173– 1181. 19. Cunha CLP, Giuliani ER, Fuster V, et al: Preoperative M-mode echocardiography as a predictor of surgical results in chronic aortic insufficiency. J Thorac Cardiovasc
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 14
Surg 1980;79:256–265. 20. Bonow RO, Rosing DR, Kent KM, Epstein SE: Timing of operation for chronic
aortic regurgitation. Am J Cardiol 1982;50:325–336. 21. Carabello BA, Green LH, Grossman W, et al: Hemodynamic determination of
prognosis of aortic valve replacement in critical aortic stenosis and advanced congestive heart failure. Circulation 1980;62:42. 22. Connolly HM, Oh JK, Schaff HV, et al: Severe aortic stenosis with low
transvalvular gradient and severe left ventricular dysfunction: Result of aortic valve replacement in 52 patients. Circulation 2000;101:1940–1946. 23. Collinson J, Henein M, Flather M, et al: Valve replacement for aortic stenosis in
patients with poor left ventricular function: Comparison of early changes with stented and stentless valves. Circulation 1999;100(19 suppl):II1–5. 24. Orsinelli DA, Aurigemma GP, Battista S, et al: Left ventricular hypertrophy and mortality after aortic valve replacement for aortic stenosis: A high risk subgroup identified by preoperative relative wall thickness. J Am Coll Cardiol 1993;22:1679– 1683. 25. Aurigemma G, Battista S, Orsinelli D, et al: Abnormal left ventricular intracavitary
flow acceleration in patients undergoing aortic valve replacement for aortic stenosis: A marker for high postoperative morbidity and mortality. Circulation 1992;86:926– 936. 26. Casale PN, Devereux RB, Milner M, et al: Value of echocardiographic measurement of left ventricular mass in predicting cardiovascular morbid events in hypertensive men. Ann Intern Med 1986;105:173–178. 27. Levy D, Garrison RJ, Savage D, et al: Prognostic implications of
echocardiographically determined left ventricular mass in the Framingham Heart Study. N Engl J Med 1990;322:1561–1566. 28. Levy D, Garrison RJ, Savage D, et al: Left ventricular mass and incidence of
coronary heart disease in an elderly cohort. Ann Intern Med 1990;110:101–107. 29. Koren M, Devereux R, Casale PN, et al: Relation of LV mass and geometry to morbidity and mortality in uncomplicated essential hypertension. Ann Intern Med 1991;114:345–352. 30. Verdecchia P, Schillaci G, Borgioni C, et al: Adverse prognostic significance of
concentric remodeling of the left ventricle in hypertensive patients with normal left
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 14
ventricular mass. J Am Coll Cardiol 1995;25:871–878. 31. Devereux R: Left ventricular geometry, pathophysiology and prognosis. J Am Coll
Cardiol 1995;25:885–887. 32. Savage DD, McGhee DL, Oster G: Hypertension associated heart disease among
black Americans. Milbank Q 1987;65:297–321. 33. Krumholz HM, Larson M, Levy D: Prognosis of left ventricular geometric patterns
in the Framingham Heart Study. J Am Coll Cardiol 1995;25:879. 34. Reichek N: Magnetic resonance imaging for assessment of myocardial function.
Magn Reson Q 1991;7:255–274. 35. Buchalter MB, Weiss JL, Rogers WJ, et al: Noninvasive quantification of left
ventricular rotational deformation in normal humans using magnetic resonance imaging myocardial tagging. Circulation 1990;81:1236–1244. 36. Dumesnil J: A mathematical model of the dynamic geometry of the intact left
ventricle and its application to clinical data. Circulation 1979;59:1024–1034. 37. deSimone G, Devereux RB, Roman MJ, et al: Assessment of left ventricular
function by the midwall fractional shortening/end systolic stress relation in human hypertension. J Am Coll Cardiol 1994;23:1444–1451. 38. Reichek N, Wilson J, St. John Sutton M, et al. Noninvasive determination of left
ventricular end-systolic stress: Validation of the method and initial application. Circulation 1982;65:99–108. 39. Gaasch WH, Zile MR, Hoshino PK, et al: Stress-shortening relations and myocardial blood flow in compensated and failing canine hearts with pressure overload hypertrophy. Circulation 1989;79:872–883. 40. St. John Sutton M, Plappert T, Hirshfeld JW, et al: Assessment of left ventricular
mechanics in patients with asymptomatic aortic regurgitation: A two-dimensional echocardiographic study. Circulation 1984;69:259–270. 41. Mirsky I: Review of the various theories for evaluation of left ventricular wall
stress. In Mirsky I, Chiston DN, Sandler H, (eds): Cardiac Mechanics: Physiological, Chemical, and Mathematical Considerations. New York, John Wiley, 1974. 42. Douglas PS, Reichek N, Plappert T, et al: Comparison of echocardiographic
methods for assessment of left ventricular shortening and wall stress. J Am Coll
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 14
Cardiol 1987;9:945–951. 43. Colan SD, Borow KM, Neumann A: Use of the calibrated carotid pulse tracing for
calculation of left ventricular pressure and wall stress throughout ejection. Am Heart J 1985;109:1306–1310. 44. Rozich JD, Carabello BA, Usher BW, et al: Mitral valve replacement with and without chordal preservation in patients with chronic mitral regurgitation. Circulation 1992;86:1718–1726. 45. Gaasch WH, Battle WE, Oboler AD, et al: Left ventricular stress and compliance
in man: With special reference to normalized ventricular function curves. Circulation 1972;45:746–762. 46. Clyne CA, Arrighi JA, Maron BJ, et al: Systemic and LV responses to exercise
stress in asymptomatic patients with valvular aortic stenosis. Am J Cardiol 1991;68:1469–1476. 47. Cuocolo A, Sax F, Brush J, et al: Left ventricular hypertrophy and impaired
diastolic filling in essential hypertension. Circulation 1990;81:978–986. 48. Kitzman D, Higginbotham M, Cobb F, et al: Exercise intolerance in patients with
heart failure and preserved LV systolic function. J Am Coll Cardiol 1991;7:1065– 1072. 49. Bonow RO, Udelson JE: LV diastolic dysfunction as a cause of congestive heart
failure. Ann Intern Med 1992;117:502–510. 50. Schwinger RH, Bohm M, Koch A, et al: The failing heart is unable to use the
Frank-Starling mechanism. Circ Res 1994;74:959–969. 51. Ross J Jr: Afterload mismatch and preload reserve: A conceptual framework for
the analysis of ventricular function. Prog Cardiovasc Dis 1976;18:255–264. 52. Grossman W, Jones D, McLaurin LP: Wall stress and patterns of hypertrophy in
the human left ventricle. J Clin Invest 1975;56:56–64. 53. Pouleur H, Covell JW, Ross J Jr: Effects of alterations in aortic input impedance on
the force-velocity-length relationship in the intact canine heart. Circ Res 1979;45:126– 135. 54. Gaasch WH: LV radius to wall thickness ratio. Am J Cardiol 1979;43:1189–1194.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 14
55. Goldfine H, Aurigemma GP, Zile MR, Gaasch WH: Left ventricular length-force-
shortening relations before and after surgical correction of chronic mitral regurgitation. J Am Coll Cardiol 1998;31:180–185. 56. Carabello BA, Spann JF: The uses and limitations of end-systolic indices of left
ventricular function. Circulation 1984;69:1058–1064. 57. Sagawa K: The end-systolic pressure-volume relationship of the ventricle:
Definitions, modifications, and clinical use. Circulation 1981;61:1223–1227. 86
58. Douglas PS, Morrow R, Ioli A, et al: Left ventricular shape, afterload and survival
in idiopathic dilated cardiomyopathy. J Am Coll Cardiol 1989;13:311–315. 59. Borow KM, Lang RM, Neumann A, et al: Physiologic mechanisms governing
hemodynamic responses to positive inotropic therapy in patients with dilated cardiomyopathy. Circulation 1988;77:625–637. 60. Devereux R, Reichek N: Echocardiographic determination of left ventricular mass
in man. Anatomic validation of the method. Circulation 1977;55:613–618. 61. Devereux RB, Alonso D, Lutas E, et al: Echocardiographic assessment of left
ventricular hypertrophy: Comparison to necropsy findings. Am J Cardiol 1986;57:450–458. 62. Devereux R: Detection of LV hypertrophy by M-mode echocardiography:
Anatomic validation, standardization and comparison to other methods. Hypertension 1987;9(suppl II):19–26. 63. Reichek N: Standardization in the measurement of left ventricular wall mass.
Hypertension 1987;9(suppl II):II27–29. 64. Vuille C, Weyman AE: Left ventricle I: General considerations, assessment of
chamber size and function. In Weyman AE (ed): Principles and Practice of Echocardiography, 2nd ed. Philadelphia, Lea & Febiger, 1994, pp 575–624. 65. Borow K: An integrated approach to the noninvasive assessment of left ventricular
systolic and diastolic performance. In St. John Sutton M, Oldershaw P (eds): Textbook of Echocardiography. Boston, Blackwell Scientific Publications, 1989, pp 97–152.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 14
66. Teichholz LE, Kreulen T, Herman MV, et al: Problems in echocardiographic
volume determinations: Echocardiographic-angiographic correlations in the presence or absence of asynergy. Am J Cardiol 1976;37:7–12. 67. Kronik G, Slany J, Mosslacher H: Comparative value of eight M-mode
echocardiographic formulas for determining left ventricular stroke volume. Circulation 1979;60:1308–1316. 68. Ganau A, Devereux R, Roman M, et al: Patterns of LV hypertrophy and geometric
remodeling in essential hypertension. J Am Coll Cardiol 1992;19:1550–1560. 69. Ford LE: Heart size. Circ Res 1976;39:297. 70. Aurigemma G, Silver K, McLaughlin M, et al: Impact of chamber geometry and
gender on LV systolic function in patients over 60 years of age with aortic stenosis. Am J Cardiol 1994;74:794–798. 71. Krumholz HM, Larson M, Levy D: Prognosis of left ventricular geometric patterns
in the Framingham Heart Study. J Am Coll Cardiol 1995;25:879–884. 72. Topol E, Traill T, Fortuin N: Hypertensive hypertrophic cardiomyopathy of the
elderly. N Engl J Med 1985;312:277–283. 73. Pearson AC, Gudipati CV, Labovitz A: Systolic and diastolic flow abnormalities in
elderly patients with hypertensive hypertrophic cardiomyopathy. J Am Coll Cardiol 1988;12:989–995. 74. Lewis JF, Maron BJ: Elderly patients with hypertrophic cardiomyopathy: A subset
with distinctive LV morphology and progressive clinical course late in life. J Am Coll Cardiol 1989;13:36–45. 75. Fay WP, Taliercio CP, Ilstrup DM, et al: Natural history of hypertrophic
cardiomyopathy in the elderly. J Am Coll Cardiol 1990;16:821–826. 76. Litwin SE, Katz SE, Weinberg EO, et al: Serial echocardiographic Doppler
assessment of left ventricular geometry and function in rats with pressure-overload hypertrophy: Chronic angiotensin converting enzyme inhibition attenuates the transition to heart failure. Circulation 1995;91:2642–2649. 77. Schiller N, Shah P, Crawford M, et al: Recommendations for quantitation of the
left ventricle by two-dimensional echocardiography. J Am Soc Echocardiogr 1989;2:358–367.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 14
78. Schiller NB: Considerations in the standardization of measurement of LV
myocardial mass by two-dimensional echocardiography. Hypertension 1987;9(suppl II):II33–35. 79. Reichek NR, Helak J, Plappert T, et al: Anatomic validation of left ventricular
mass from clinical two-dimensional echocardiography: Initial results. Circulation 1983;67:348–352. 80. Tortoledo FA, Quinones MA, Fernandez GC, et al: Quantification of left
ventricular volumes by two dimensional echocardiography: A simplified and accurate approach. Circulation 1982;67:579–584. 81. Wahr DW, Schiller NB: Left ventricular volumes determined by two-dimensional
echocardiography in a normal adult population. J Am Coll Cardiol 1983;1:863–868. 82. St. John Sutton MG, Plappert T, Crosby L, et al: Effects of reduced left ventricular
mass on chamber architecture, load, and function: A study of anorexia nervosa. Circulation 1985;72:991–1000. 83. Byrd BF, Wahr D, Wang YS, et al: Left ventricular mass and volume/mass ratio
determined by two-dimensional echocardiography in normal adults. J Am Coll Cardiol 1985;6:1021–1025. 84. Douglas PS, Reichek N, Hackney K, et al: Contribution of afterload, hypertrophy,
and geometry to left ventricular ejection fraction in aortic valve stenosis, pure aortic regurgitation and idiopathic dilated cardiomyopathy. Am J Cardiol 1987;59:1398– 1404. 85. Feiring A, Rumberger J, Reiter S, et al: Determination of left ventricular mass in
dogs with rapid-acquisition cardiac computed tomographic scanning. Circulation 1985;72:1355–1364. 86. Martin RP: Real time ultrasound quantitation of ventricular function: Has the
eyeball been replaced or will the subjective become objective? J Am Coll Cardiol 1993;19:321–323. 87. Amico AF, Reisner SA, Stone CK, et al: Superiority of visual versus computerized
echocardiographic estimation of radionuclide left ventricular ejection fraction. Am Heart J 1989;118:1259–1265. 88. Perez JE, Waggoner AD, Barzilai B, et al: On-line assessment of ventricular
function by automatic boundary detection and ultrasonic backscatter imaging. J Am Coll Cardiol 1992;19:313–320.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 14
89. Perez JE, Klein SC, Prater DM, et al: Automated on-line quantitation of left
ventricular dimensions and function by echocardiography with backscatter imaging and lateral gain compensation. Am J Cardiol 1992;70:1200–1205. 90. Vandenburg BF, Rath LS, Stuhlmiller P, et al: Estimation of left ventricular cavity
area with an on-line semiautomated echocardiographic edge detection system. Circulation 1992;86:159–166. 91. King DL: Three-dimensional echocardiography: Use of additional spatial data for
measuring left ventricular mass. Mayo Clin Proc 1994;69:293–295. 92. King DL, Gopal AS, Keller AM, et al: Three-dimensional echocardiography
advances for measurement of ventricular volume and mass. Hypertension 1994;23:172. 93. King DL, Harrison MR, King DL Jr, et al: Ultrasound beam orientation during
standard two-dimensional imaging: Assessment by three dimensional echocardiography. J Am Soc Echocardiogr 1992;5:567–576. 94. Schmidt MA, Ohazama CJ, Agyeman KO, et al: Real-time three-dimensional
echocardiography for measurement of left ventricular volumes. Am J Cardiol 1999;84:1434–1439. 95. Gardin JM, Tomasso CL, Talano JV: Evaluation of dilated cardiomyopathy by
pulsed Doppler echocardiography. Am Heart J 1983;106:1057–1065. 96. Lewis JF, Kuo LC, Nelson JG, et al: Pulsed Doppler echocardiographic
determination of stroke volume and cardiac output: Clinical validation of two new methods using the apical window. Circulation 1984;70:425–431. 97. Bargiggia GS, Bertucci C, Recusani F, et al: A new method for estimating left
ventricular dP/dt by continuous wave Doppler-echocardiography: Validation studies at cardiac catheterization. Circulation 1989;80:1287–1292. 98. Pai RG, Bansal RC, Shah P: Doppler-derived rate of left ventricular pressure rise.
Circulation 1990;82:514–520. 99. Chen C, Rodriguez L, Guererro JL, et al: Noninvasive measurement of the
instantaneous first derivative of left ventricular pressure using continuous wave Doppler echocardiography. Circulation 1991;83:2101–2110. 100. Aurigemma GP, Reichek N, Venugopal R, et al: Automated left ventricular mass,
volume, and shape from 3D MRI: In vitro validation. Am J Card Imaging 1991;5:257– 263.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 14
101. Maddahi J, Crues J, Berman DS, et al: Noninvasive quantification of left ventricular myocardial mass by gated proton nuclear magnetic resonance imaging. J Am Coll Cardiol 1987;10:682–692. 102. Shapiro EP, Rogers WJ, Beyar R, et al: Determination of left ventricular mass by
magnetic resonance imaging in hearts deformed by acute infarction. Circulation 1989;79:706–711. 103. Utz JA, Herfkens RJ, Heinsimer JA: Cine MR determination of left ventricular
ejection fraction. AJR Am J Roentgenol 1987;148:839–849. 87
104. Aurigemma G, Reichek N, Schiebler M, Axel L: Evaluation of mitral
regurgitation by cine magnetic resonance imaging. Am J Cardiol 1990;66:621–625. 105. Aurigemma G, Reichek N, Schiebler M, Axel L: Evaluation of aortic
regurgitation by cardiac cine magnetic resonance imaging: Planar analysis and comparison to Doppler echocardiography. Cardiology 1991;78:340–347. 106. Cranney G, Lotan C, Dean L, et al: Left ventricular volume measurements using
cardiac axis nuclear magnetic resonance imaging. Circulation 1990;82:154–163. 107. Aurigemma GP, Davidoff A, Silver K, Boehmer J: Left ventricular mass
quantitation using single-phase cardiac MRI. Am J Cardiol 1992;70:259–262. 108. Carlson MD, White RD, Trohman RG, et al: Right ventricular outflow tract
ventricular tachycardia: Detection of previously unrecognized anatomic abnormalities using cine magnetic resonance imaging. J Am Coll Cardiol 1994;24:720–727. 109. Allen DG, Kentish JC: The cellular basis of the length tension relation in cardiac
muscle. J Mol Cell Cardiol 1985;17:821–828. 110. Quinones MA, Waggoner AD, Nelson JG, et al: A new simplified and accurate
method for determining ejection fraction with two dimensional echocardiography. Circulation 1981;64:744–752. 111. Ross J Jr: Afterload mismatch in aortic and mitral valve disease: Implications for
surgical therapy. J Am Coll Cardiol 1985;5:811–826.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 14
112. St. John Sutton M, Plappert T, Spiegel A, et al: Early post-operative changes in
LV chamber size, architecture, and function in aortic stenosis and aortic regurgitation and their relation to intraoperative changes in afterload: A prospective twodimensional echocardiographic study. Circulation 1987;76:77–89. 113. DeFilippi CR, Willett DL, Brickner ME, et al: Usefulness of dobutamine
echocardiography in distinguishing severe from non-severe valvular aortic stenosis in patients with depressed left ventricular function and low transvalvular gradients. Am J Cardiol 1995;75:191–194. 114. Colan SD, Borow KM, Neuman AS: The left ventricular end-systolic wall stress-
velocity of fiber shortening relation: A load independent index of myocardial contractility. J Am Coll Cardiol 1984;4:715–724. 115. Quinones MA, Gaasch WH, Alexander JK: Influences of acute changes in
preload, afterload, contractile state, and heart rate on ejection and isovolumic indices of myocardial contractility in man. Circulation 1976;53:293–300. 116. Aurigemma GP, Meyer TE, Sharma M, et al: Evaluation of extent of shortening
versus velocity of shortening at the endocardium and midwall in hypertensive heart disease. Am J Cardiol 1999;83:792–794. 117. Shimizu G, Zile M, Blaustein AS, Gaasch WH: Left ventricular chamber filling
and midwall fiber lengthening in patients with left ventricular hypertrophy: Overestimation of fiber velocities by conventional midwall measurements. Circulation 1985;71:266–272. 118. Aurigemma GP, Silver KH, Fox MA, et al: Depressed midwall and long axis
shortening in hypertensive left ventricular hypertrophy with normal ejection fraction. J Am Coll Cardiol 1995;26:195–202. 119. Keren G, LeJemtel T: Mitral annulus motion: Relation to pulmonary venous and
transmitral flows in normal subjects and in patients with dilated cardiomyopathy. Circulation 1988;78:621–629. 120. Jones CR, Gibson D: Functional importance of the long axis dynamics of the
human left ventricle. Br Heart J 1990;65:215–220. 121. Palmon L, Reichek N, Yeon S, et al: Intramural myocardial shortening in
hypertensive left ventricular hypertrophy with normal pump function. Circulation 1994;89:122–131. 122. Sohn DW, Chai IH, Lee DJ, et al: Assessment of mitral annulus velocity by
Doppler tissue imaging in the evaluation of left ventricular diastolic function. J Am
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 14
Coll Cardiol 1997;30:474–480. 123. Nagueh SF, Middleton KJ, Kopelen HA, et al: Doppler tissue imaging: a
noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures. J Am Coll Cardiol 1997;30:1527–1533. 124. Sutherland GR, Stewart MJ, Groundstroem KWE, et al: Color Doppler
myocardial imaging: A new technique for the assessment of myocardial function. J Am Soc Echocardiogr 1994;7:441–458. 125. Mirsky I, Pasternac A, Ellison RC: General index for the assessment of cardiac
function. Am J Cardiol 1972;30:483–491. 126. Ross J Jr: Adaptations of the left ventricle to chronic valvular overload. Circ Res
1974;35:64–70. 127. Ross J Jr, Sonnenblick EH, Taylor RR, et al: Diastolic geometry and sarcomere
lengths in the chronically dilated canine left ventricle. Circ Res 1971;28:49–56. 128. Sonnenblick EH: Correlation of myocardial ultrastructure and function.
Circulation 1968;38:29–44. 129. Laks MM, Morady F, Swan HJC: Canine right and left ventricular cell and
sarcomere lengths after banding the pulmonary artery. Circ Res 1969;24:705–710. 130. Greenbaum R, Ho S, Gibson D: Left ventricular fibre architecture in man. Br
Heart J 1981;45:248–263. 131. Streeter D, Spotnitz H, Patel D: Fiber orientation in the canine left ventricle
during diastole and systole. Circ Res 1969;24:339–346. 132. Villareall FJ, Lew WYW, Waldman LK et al: Transmural myocardial deformation
in the ischemic canine left ventricle. Circ Res 1991;68:368–381. 133. Clark NR, Reichek N, Bergey P, et al: Circumferential myocardial shortening in
the normal human left ventricle. Assessment by magnetic resonance imaging using spatial modulation of magnetization. Circulation 1991;84:67–74. 134. Sagawa K, Maughan L, Suga H, Sunagawa K: Cardiac Contractility and the
Pressure-Volume Relationship. New York, Oxford University Press, 1988. 135. Magorien DJ, Shaffer P, Bush CA, et al: Assessment of left ventricular pressure-
volume relations using gated radionuclide angiography, echocardiography and
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 14
micromanometer pressure recordings. Circulation 1983;67:844–852. 136. McKay RG, Aroesty JM, Heller GV, et al: Left ventricular pressure-volume
diagrams and end-systolic pressure-volume relations in human beings. J Am Coll Cardiol 1984;3:301–312. 137. Gorcsan J III, Gasior TA, Mandarino WA: Assessment of the immediate effects of cardiopulmonary bypass on left ventricular performance by on-line pressure-area relations. Circulation 1994;89:180–190. 138. Gorcsan J III, Denault A, Gasior TA, et al: Rapid estimation of LV contractility
from end systolic relations by echocardiographic automated border detection and femoral artery pressure. Anesthesiology 1994;81:553–562. 139. Katz WE, Gasior TA, Reddy SC, Gorcsan J III: Utility and limitations of biplane
transesophageal echocardiography for estimation of LV stroke volume. Am Heart J 1994;128:389–396. 140. Sagawa K: The ventricular pressure-volume diagram revisited. Circ Res
1978;43:677–680. 141. Bogen DK, Ariel Y, McMahon TA, Gaasch WH: Measurement of peak systolic
elastance in intact canine circulation with servo pump. Am J Physiol 1985;249:H585– H593. 142. Berko B, Gaasch WH, Tanigawa N, et al: Disparity between ejection and end
systolic indexes of left ventricular contractility in mitral regurgitation. Circulation 1987;75:1310–1319. 143. Gaasch WH, Carroll JD, Levine HJ, et al: Chronic aortic regurgitation: Prognostic
value of left ventricular end-systolic dimension and end-diastolic radius/thickness ratio. J Am Coll Cardiol 1983;1:775–782. 144. Gottdiener JS, Livengood SV, Meyer PS, et al: Should echocardiography be
performed to assess the effects of antihypertensive therapy? Test-retest reliability of echocardiography for measurement of left ventricular mass and function. J Am Coll Cardiol 1995;25:424–430. 145. Dahloff B, Pennert K, Hanson L: Reversal of left ventricular hypertrophy in
hypertensive patients: A meta-analysis of 109 treatment studies. Am J Hypertens 1992;5:95–110.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 14
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26017484/1031/38.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
88
Chapter 5 - Quantitative Evaluation of Regional Left Ventricular Systolic Function Florence H. Sheehan MD
Two-dimensional (2D) echocardiography is well suited to the assessment of regional left ventricular systolic function for both clinical and research applications. Every region of the ventricle can be examined at high spatial and temporal resolution, allowing a more comprehensive visualization than with other imaging modalities. Furthermore, echocardiography is portable, safe, and relatively inexpensive, so serial studies can be obtained without risk to the patient to follow disease progression or response to therapy. Quantitative methods have been developed for measurement of systolic function both for diagnosis and for evaluation of treatment efficacy and prognosis in patients with ischemic heart disease. These methods also allow analysis of the structure-function relationship of the left ventricle and mitral valve, of asynchrony in the timing of contraction, and of the heart's compensatory response to disease processes. Thus, echocardiographic examination offers high informational content for both clinical and research applications.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/39.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 4
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Semiquantitative Assessment of Regional Systolic Function In clinical practice, visual assessment provides a rapid evaluation of regional systolic function. In each imaging plane, the ventricular contour is divided into several segments. Each segment is assigned a numeric value that indicates its degree of asynergy. Methodology Segmentation of Ventricle
Several schemata have been devised for dividing the ventricle into 14 to 20 segments.[1] [2] The American Society of Echocardiography's most recent recommendation is for a 16-segment model (Fig. 5-1) .[2] The goal is to obtain sufficient detail to characterize the pattern of dysfunction 89
Figure 5-1 Sixteen-segment model for visual assessment of regional wall motion, recommended by the American Society of Echocardiography. A, anterior; AL, anterolateral; AS, anteroseptal; PL or IL, postero-or inferolateral; I or P, inferior or posterior; IS or PS, infero- or postero-septal; RV, right ventricle; L, lateral; S, septal. (From Schiller NB, Shah PM, Crawford M, et al: Am Soc Echocardiogr 1989;2:358–367.)
in patients with ischemic heart disease without overburdening the clinician. The locations of the segments follow the perfusion territory of the three major epicardial arteries (Fig. 5-2) to facilitate the diagnosis of ischemic dysfunction. Wall Motion Score
The severity of dysfunction is scored visually in each segment. The recommended standard assigns a score of 1 for normal contraction or
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 4
hyperkinesis, 2 for hypokinesis, 3 for akinesis, 4 for dyskinesis, and 5 for aneurysmal segments. [2] Some investigators use the system developed for angiography by Herman and Gorlin,[3] which assigns 1 for normal motion, 2 for mild or moderate hypokinesis, 3 for severe hypokinesis or akinesis, 4 for dyskinesis, and 5 for aneurysmal segments. Gibson et al[4] recommended evaluating wall thickening as well as motion in scoring segmental function because of reports that wall motion varies widely in normal subjects. However, wall thickening evaluation is not included in the American Society of Echocardiography's recommendation for regional function assessment.[2] Hyperkinesis can be distinguished from normal motion and may be assigned a negative value (e.g., -1) to indicate that its contribution to global function is opposite to that of segments with depressed function.[5] A global wall motion score is then calculated by summing or averaging the readings in all of the segments. The region of infarction can be evaluated separately from the noninfarct region by averaging the scores in the appropriate subset of segments. [6] Validation Comparison with Other Imaging Modalities
In clinical validation studies, the echocardiographic score agreed exactly with the score obtained from contrast ventriculograms in 44% of segments; agreement within one functional class was seen in 68% to 88% (Table 5-1) [7] [8] [9] [10] [11] [12] that is, agreement is higher for distinguishing normal from abnormal contraction than in identifying grades of abnormality. Comparable results were obtained in comparisons of radionuclide ventriculography versus 2D echocardiography (see Table 5-1) .[9] [13] In a significant minority of patients, however, the discordance is two or three classes. In one study, the global wall motion score by 2D echocardiography and angiography correlated with r = .70.[11] Factors Affecting Diagnostic Accuracy
Many factors influence the apparent accuracy of qualitative assessment of wall motion. Obvious direct factors are image quality and correct positioning of the image plane relative to the left ventricle. Another important factor is the difference between imaging modalities. Unlike contrast and radionuclide ventriculography, 2D echocardiography is tomographic, producing images of discrete slices of the heart; therefore, the different modalities do not obtain exactly comparable views of each
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 4
segment. The training and experience of the observer are also important, both in recognizing normality and in differentiating classes of abnormality. Even with adequate training, significant intra- and interobserver variability exists in visual assessment. In general, variability increases with the number of grades. Exact agreement within and between observers ranges from 81% to 95%.[14] [15] [16] [17] However, allowance of a one-grade error (e.g., combining normal with hypokinesis or dyskinesis with aneurysm) improves intra- and interobserver agreement to 98% to 99%. These variability rates are comparable to those reported for the 90
Figure 5-2 Regions of single-vessel infarct asynergy. The maximum predicted area of infarct akinesis or dyskinesis and adjacent, noninfarct hypokinesis is depicted for each coronary artery. The ventricular model is based on 11 segments evaluated from short-axis sections obtained at the level of the mitral valve, papillary muscles, and apex. The mitral and papillary level sections were each divided into five segments. LAD, left anterior descending coronary artery; LCX, left circumflex coronary artery; RCA, right coronary artery. (From Stamm RB, Gibson RS, Bishop HL: Circulation 1983;67:232– 244.)
visual assessment of wall motion from contrast ventriculograms.[18] [19] To minimize the impact of observer variability, most studies report readings made by consensus between two or more observers. Variability reduces the sensitivity of qualitative assessment in diagnosing abnormality or detecting change in function. In patients studied after bypass surgery, wall motion in the revascularized segments improved significantly from baseline values when measured quantitatively, but they did not improve significantly when assessed visually.[20] Nevertheless, the global wall motion score has been repeatedly shown to predict survival in patients with acute or chronic myocardial infarction.[11] [21] Other clinical applications TABLE 5-1 -- Diagnostic Accuracy of Semiquantitative Echocardiography Analysis: Agreement Analysis: Agreement with Other with Other Imaging Modalities No. of Patients Echo Views No. of Classes
% Concordance ±1 COMPLETE CLASS Reference
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Comparison with contrast ventriculography 105 4 SAX, 1 apical 66 2 apical 24 2 parast, 2 apical 47 2 parast, 2 apical 47 2 parast, 2 apical 50 3 SAX, 3 LAX 20 2 parast, 2 apical Comparison with radionuclide ventriculography 24 2 parast, 2 apical 39 Subcostal
Pagina 4 di 4
2: normal vs. abnormal 4: nl, hypo, ak, dys
— 94
2: nl/hypo, ak/dys
—
87 Kisslo et al[7] 100 Ohuchi et al[8] 68 Hecht et al [9]
2: normal vs. abnormal 4: nl, hypo, ak, dys
—
5: nl, hypo, ak, dys, aneur 2: normal vs. abnormal
44
2: nl/hypo, ak/dys
—
69
—
79 Freeman et al[10] 94 Freeman et al[10] 88 Shiina et al[11] 77 Lundgren et al[12]
64 Hecht et al [9]
5: hyper, nl, hypo, 86 98 Ginzton et ak, dys al[13] ak, akinesis; aneur, aneurysm; dys, dyskinesis; hypo, hypokinesis; LAX, long axis (include apical views and parasternal long-axis view); nl, normal; parast, parasternal; SAX, short axis. are diagnosis of acute infarction in patients with nondiagnostic electrocardiograms, estimation of infarct size, and prediction of complications of infarction.[4] [22] [23]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/40.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 24
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Quantitative Analysis of Regional Systolic Function Overview of Calculable Parameters As a tomographic imaging modality, 2D echocardiography allows delineation of both the endocardial and epicardial contours of the left ventricle. Consequently, it is 91
possible to calculate not only those parameters reflecting endocardial displacement, such as are used to analyze contrast ventriculograms, but also parameters based on measuring wall thickness. For clinical applications, the most commonly measured parameters are wall motion and wall thickening. The velocity of wall motion can also be measured by analyzing the Doppler signals generated by myocardial tissue. For research, other parameters of interest include midwall shortening, epicardial motion, shape, and wall stress. These measurements can be performed not only in two dimensions, within the plane of imaging, but also in three dimensions and even in four dimensions, with time. Through multiplanar image acquisition, echocardiography provides more complete visualization of the left ventricle than can be provided by either radionuclide or contrast ventriculography. Methods have been developed for three-dimensional (3D) reconstruction of the endocardium and epicardium and for performing 3D analysis of left ventricular dimensions, shape, and regional and global function (see Chapter 10) . Unlike with other imaging modalities, the visibility of landmarks on echocardiogram images (e.g., the papillary muscles, valve planes, and right ventricular septal insertion) helps to localize functional defects on the ventricle. From a multiplanar analysis of function, an estimate of infarct size can be derived by mapping the location of the dysfunctional region on the endocardial surface.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 24
The analysis of function, both regional and global, measures the alteration of the left ventricle between two time points in the cardiac cycle. For clinical purposes, the contours at end-diastole and end-systole are generally compared. Some investigators have also studied the extent of contraction at specific phases such as during isovolumic contraction or relaxation.[24] Frame-by-frame analysis through the cardiac cycle provides information on the synchrony of regional function. This can be taken to the "fourth dimension" by performing 3D analyses of the left ventricle at multiple time points through the cardiac cycle. Four-dimensional analysis is feasible with currently available fast computer technology and is being undertaken for teaching purposes. Application to clinical medicine will require automated border detection (see Chapter 7) to relieve the labor and tedium associated with analyzing so many images. Wall Motion Wall motion analysis measures the displacement of the left ventricular endocardium. To normalize for patient-to-patient differences in heart size, the measured motion is divided by the left ventricular dimension at enddiastole. The resulting unitless shortening fraction is analogous, on a local and linear level, to the global volume ejection fraction. Unlike the ejection fraction, however, wall motion may have negative values, which indicate paradoxical outward motion during systole. Implicit Assumptions
There are two major assumptions implicit in wall motion analysis. The first is that a one-to-one correspondence can be made from anatomic points on the left ventricular contour at end-diastole to the same points at end-systole. Second, the location of the patient relative to the imaging equipment remains stable. In fact, both assumptions are compromised in 2D image analysis. Nevertheless, the methods developed for wall motion analysis attempt to deal with these sources of imprecision. Methods for Wall Motion Analysis
Because it is not possible to track specific points on the left ventricle over time, there is no gold standard for judging the accuracy of methods for measuring wall motion. As a consequence, there is a plethora of methods, all of which model rather than measure wall motion. Almost all methods available for analysis of wall motion from echocardiogram images were developed initially for contrast ventriculograms. Ventriculograms have
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 24
only one clearly visible landmark—the aortic valve—although some investigators attempt to identify the apex as a second landmark even though it is not an anatomic structure. Because the aortic valve is the only structure whose motion can be tracked over time, all other points on the ventricle have to be identified by their distance from the aortic valve. Echocardiograms display more anatomic landmarks, but they have not been used to make additional correspondences between the endocardial contour at end-diastole and end-systole, probably because the descent of the base toward the apex during systole moves different "slices" of the ventricle into and out of the imaging plane, so that the landmarks cannot be tracked over time. Most wall motion analysis methods for echocardiography employ a radial coordinate system. Motion is assumed to proceed from all points on the endocardial contour toward a single point, the center of area (Fig. 5-3) . There is little evidence supporting this assumption, although some data suggest a multicentric motion pattern.[25] However, the radial approach seems inherently suited to analysis of short-axis images. The radial method has also been applied to contours from apical views.[26] In methods based on a rectangular coordinate system, motion is measured along hemiaxes constructed at intervals along and perpendicular to the long axis of the ventricle. Rectangular coordinate system methods are applied only to apical views.[27] [28] [29] The apex is the least well visualized part of the contour; therefore, construction of a coordinate system based on identification of the apex may be subject to variability. One author justified the coordinate system approach by its similarity at the apex to a method derived by tracking endocardial landmarks felt to represent trabeculae.[30] The concept in these two methods is that endocardial displacement at the apex results from apical obliteration as the lateral walls contract toward the long axis. However, a study that also tracked endocardial landmarks found that apical wall motion proceeds toward the base, that is, 90 degrees off from the direction dictated by the first endocardial landmark method.[31] An angiographic analysis of the motion of surgically implanted metallic markers also reported that apical wall motion proceeds toward the base.[32] Thus, the 92
Figure 5-3 Method used for analysis of regional left ventricular
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 24
contraction in a schematic of a short-axis two-dimensional echocardiographic image. The junction between the posterior right ventricular free wall endocardium and right ventricular septal endocardium was chosen as a landmark and a line drawn to the farthest point on the lateral left ventricular wall epicardium. From the midpoint of this line (1–7), 12 equidistant radii are drawn to separate the image into 12 cavity and wall segments. Percentage area change of each cavity segment and percentage thickening of the wall along each radius during systole are calculated. Solid lines, end-diastole; interrupted lines, end-systole. (From Pandian NG, Skorton DJ, Collins SM, et al: Am J Cardiol 1983; 51:1667–1673. Reprinted with permission from Excerpta Medica Inc.)
rectangular coordinate system, endocardial landmark, and midwall marker methods produce radically different descriptions of the direction of endocardial displacement at the apex. Only part of this discrepancy can be explained by the differing motions of the endocardium versus the midwall, which become separated during systole owing to relatively greater thickening of the inner myocardium.[33] Little of the discrepancy can be attributed to left ventricular torsion that rotates different layers of myocardium to different extents around the long axis of the left ventricle.[34] The Figure 5-4 Centerline method for regional wall motion analysis. Left, End-diastolic (ED) and end-systolic (ES) endocardial contours of the left ventricle from the apical long-axis echocardiographic view with the centerline midway between the two contours. Right, One hundred equidistant chords (not all shown) are constructed perpendicular to the centerline and numbered counterclockwise from the anterior aortic valve. The motion at each chord is normalized by the end-diastolic perimeter to yield a dimensionless chord fractional shortening. (From Wohlgelernter D, Cleman M, Highman A, et al: J Am Coll Cardiol 1986;7:1245–1254. Reprinted with permission from the American College of Cardiology.)
disagreement between these studies illustrates the current lack of knowledge and forms the justification for modeling rather than attempting to measure regional wall motion, at least until more definitive results can be obtained. Two methods have been developed for modeling wall motion without using a coordinate system. Gibson et al[35] divide the end-diastolic contour into a number of evenly spaced points and measure the distance from each to the nearest point on the end-systolic contour. In the centerline method, a centerline is drawn midway between the end-diastolic and end-systolic contours. Motion is measured along 100 chords evenly spaced along and
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 24
perpendicular to the centerline and normalized by the end-diastolic perimeter length (Fig. 5-4) .[36] [37] [38] [39] Because they make no assumptions concerning the geometry of the left ventricular contour, both methods can be applied to chambers of diverse shapes. For example, the centerline method has been used to measure wall motion in the right ventricle as well as from different views of the left ventricle, unaffected by distortions of ventricular shape resulting from disease processes. Wall Motion Parameters
Motion can be measured in one dimension as the linear distance between the end-diastolic and end-systolic contours and normalized to yield a shortening fraction. Alternatively, function can be measured in regions of the left ventricle: the change in the area of a region between end-diastole and end-systole normalized by the end-diastolic area yields a regional ejection fraction (Fig. 5-5) . Studies have shown that such an area parameter is less subject to variability in delineating the endocardial contour, probably because the variability at individual contour points is averaged out over the region.[29] [40] [41] The principal drawback to regional assessment lies in the definition of the regions. Although the perfusion territories of the major epicardial coronary arteries have been mapped,[42] studies have shown that dysfunction in 93
Figure 5-5 Schematic of diastolic and systolic left ventricular outlines subdivided into octants, showing different approaches to measuring regional contraction. A, regional area change; H, hemiaxis shortening; P, segmental endocardial perimeter contraction. Similar measurements can be made for other approaches of segmenting the ventricular contour. (From Moynihan PF, Parisi AF, Feldman EL: Circulation 1981;63:752–760.)
patients with ischemic heart disease may extend beyond the defined territory of the stenosed artery.[5] [43] [44] [45] [46] [47] This result may be due to multivessel disease, border zone dysfunction, and/or variable coronary anatomy. In patients with multiple critical stenoses or infarctions, there may be multiple regions of dysfunction that run together and cannot be distinguished from each other.[5] The only distinguishing feature about border zone dysfunction is that it is less severe than dysfunction in the central ischemic region.[48] [49]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 24
The impact of variable coronary anatomy on the measurement of regional left ventricular function is significant, because dysfunction may be underestimated if the central ischemic region straddles two adjacent segments, each of which also containing some normally contracting myocardium.[36] One solution to this problem is to measure wall motion at many discrete points around the ventricular contour and then average the motion of points lying within the region of interest. This approach is flexible enough to adjust for variable coronary anatomy while retaining the advantage of lower variability for regional analyses, and it has been applied successfully using the centerline method to analyze function in the center of, on the periphery of, and remote from the ischemic region.[36] [50] It is important to note that the motion of multiple points from different locations on the contour cannot be averaged validly unless the motion values have comparable distributions. For wall motion, the normal mean and standard deviation vary by location on the ventricle (see "Definition of Normal Values"). One solution is to convert the shortening fraction values to a Z score (i.e., to units of standard deviations from the mean of a normal reference population).[41] After conversion, a value of zero indicates normal motion, positive values indicate hyperkinesis, and negative values indicate hypokinesis. The magnitude of the wall motion value indicates the clinical significance of the abnormality. These standardized wall motion values can be averaged over regions and compared among different regions and different patients. Validation Using Empirical Criteria
The various methods for wall motion analysis have been "validated" clinically using empirical criteria. The principal criteria are high sensitivity and specificity in distinguishing patients with diseased hearts from normal subjects. The problem with this approach is that the demonstrated diagnostic accuracy depends not only on the parameter but also on the patient populations used for testing. For example, the diagnostic accuracy of a new method will appear to be much higher if the diseased patients have myocardial infarction than if they merely suffer from chronic stable angina, simply because the latter have near-normal function. For this reason, the relative merits of the various methods of wall motion analysis are best assessed from comparative studies of two or more methods. Most comparisons have been made on contours drawn from contrast ventriculograms (Table 5-2) . These studies have shown that the radial and centerline methods have higher diagnostic accuracy than methods based on a rectangular coordinate system. One study of 2D echocardiograms in the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 24
subcostal view reported that the centerline method is less likely to diagnose abnormality in normal subjects than the radial method.[26] In contrast, another echocardiographic study found that a rectangular coordinate system approach yielded higher diagnostic accuracy than either the radial or centerline methods.[28] The homogeneity of the normal group is the second empirical criterion. A narrow normal range, reflected by a small standard deviation, enhances sensitivity in diagnosing TABLE 5-2 -- Comparison of Sensitivity and/or Specificity of Methods of Wall Motion Analysis in Detecting Regional Dysfunction Methods RadialED COM > radialES COM, LA
Reference Papapietro et al[122]
RadialLA > radialES COM, ED + ES COM
Karsch et al *
Radial > area > rectangular Area, radialmidwall >> radialED + ES COM ,
Karsch et al * Lorente et al †
rectangular in anterior MI RadialED + ES COM , radialmidwall >>
Lorente et al †
rectangular, area in inferior MI Radialmidwall > rectangular > radialED + ES Colle et al ‡ COM
Area > radialLA , rectangular
Gelberg et al[41]
Centerline, rectangular >> radialmidwall
Sheehan et al §
Centerline = radialmidwall = rectangular
Lamberti et al
Centerline >> radialmidwall
Ginzton et al[26]
Radialmidwall > radialLA , radialES COM ,
Ingels et al ¶
rectangular Rectangular > centerline, radial Assmann et al[28] A >> B, C indicates that method A was significantly better than methods B and C, and that B and C do not differ from each other; A > B indicates method A was better than method B but not compared statistically; Area
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 24
specifies that regional ejection fractions were measured; Radialmidwall
refers to the method of Ingels et al; Centerline refers to the centerline method of Sheehan et al; ED COM, origin at end-diastolic center of mass; ES COM, origin at end-systolic center of mass; ED + ES COM, origin of each contour at that contour's center of mass; LA, origin at midpoint of long axis; MI, myocardial infarction.
*Clin Cardiol 1980;3:123. †Int J Cardiol 1985;7:361. ‡Arch Mal Coeur 1982;75:395. §In Sigwart U, Heintzen PH, (eds): Ventricular Wall Motion. Stuttgart, Georg Thieme Verlag, 1984, p 139. In Computers in Cardiology. Long Beach, Calif., IEEE Computer Society, 1985, p 467. ¶Circulation 1980;61:966.
94
abnormality (Fig. 5-6) . For example, in calculating sample size for a clinical trial, the number (n) of patients per group is proportional to the square of the standard deviation (σ):
One way to evaluate a method quickly is to divide the value for the normal mean by the normal standard deviation. If the quotient is greater than 2, then akinesis is unlikely to lie within the normal range (defined as the mean ± 2 SD). If akinesis differs from the normal mean by less than 2 SD, then a patient's motion must be dyskinetic or aneurysmal to be considered definitely abnormal. Such a method is relatively insensitive to lesser degrees of dysfunction. Additional considerations in selecting a method of wall motion analysis are its ability to focus on a user-defined region of interest and its applicability to other chambers of the heart or to particularly distorted ventricular
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 24
contours. The importance of these considerations depends on the intended application. Effect of Cardiac Translation on Wall Motion Analysis
The second assumption implicit in wall motion—that the heart's position is stable—is particularly problematic for 2D echocardiography. During systole, the left ventricle rotates about its long axis and translates anteriorly. [51] [52] There is no easy way to distinguish contraction from the translational motion of the heart. Several empirical methods have been proposed to "correct for" translation by realigning the end-systolic contour relative to the end-diastolic contour (Fig. 5-7) . For contrast ventriculography, Figure 5-6 Effect of variability on diagnostic accuracy. Bottom, Probability distribution functions for a normal (—) and disease (---) population. When the variability of the measurement is low and the standard deviation (SD) is narrow, virtually no overlap exists between the two groups. Top, When variability is greater, as indicated by a higher SD, the overlap between the same two populations increases from 11% to 68%. (From Sheehan FH: Measurement of left ventricular function from contrast angiograms in patients with coronary disease. In Brundage B [ed]: Comparative Cardiac Imaging-Function, Flow, Anatomy, Quantitation. Rockville, Md, Aspen Publications, 1990, pp 101–118.)
95
Figure 5-7 Reference systems. The method of reregistration of the contours is shown on the left; the resulting superimposition of contours is shown on the right. Top, Fixed external reference system. There was no realignment of the drawn outlines between extension of radii from (in this example) the enddiastolic center of the area. Middle, Floating reference system with translation. The center of area in end-diastole and the center of area in end-systole were superimposed. Bottom, Floating reference system with translation and rotation. The centers of area in end-diastole and end-systole were superimposed for translation. The long axis from the center of the area to the apex at end-diastole was superimposed over the long axis in end-systole for rotation. □, end-diastolic center of area; •, endsystolic center of area. (From Schnittger I, Fitzgerald P, Gordon E, et al: Circulation 1984;70:242–254.)
realignment methods have no theoretical advantage over using a fixed reference system (i.e., analyzing the motion of the endocardial contour relative to the image frame [53] ) and may even worsen the reproducibility of the analysis.[40]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 24
For echocardiographic analysis, the question of realignment has not been definitively answered because of conflicting evidence. There are data to show that use of a fixed reference system may cause artifactual hypokinesis in a normal heart[54] however, using a floating reference (i.e., realigning) may present a dysfunctional segment as normal.[54] Parisi et al[55] found that fixed and floating reference systems yield equal accuracy in detecting the presence of wall motion abnormalities, but the fixed reference system was superior for localizing the abnormality. Schnittger et al[56] performed a detailed analysis of several methods for correcting for translation and rotation. They reported that the optimal analysis method differs by view. In the apical four-chamber view, correction for translation by superimposing the center of mass in the enddiastolic and end-systolic contours yielded the highest sensitivity and specificity in distinguishing patients with diseased hearts from normal subjects. However, in the short-axis view at the papillary muscle level, optimal results were obtained with a fixed reference. Zoghbi et al[57] reaffirmed the superior performance of the fixed over the floating reference analysis for the short-axis view, but they found that realignment using an epicardial centroid yielded the best correlation between wall motion and regional wall thickening. The need for realignment in the four-chamber view was reiterated by Force et al,[54] who found that patients with normal function studied after bypass surgery developed artifactual septal hypokinesis when analyzed using a fixed reference system. Feneley et al[58] [59] also found that a fixed reference causes artifactual dyskinesis in the septum when measured from short-axis images in patients with right ventricular volume overload or after bypass surgery. Wall Thickening In analyzing wall thickening, the thickness of the myocardium is measured at two or more time points in the cardiac cycle, then the measurements are compared. The thickness change is normalized by the end-diastolic dimension, as for wall motion. Normal myocardium thickens during systole. Dysfunctional myocardium exhibits decreased thickening or even thinning. Because each measurement of wall thickening is made from a single time point, thickening analysis is independent of artifact owing to cardiac translation. For this reason, many investigators prefer thickening for analyzing regional systolic function.[60] Experimental Basis
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 24
The validity of wall thickening as a parameter of regional systolic function was initially demonstrated in experimental animals. In a series of acute and chronic studies, Ross and Franklin[61] showed a linear relationship between wall thickening and subendocardial fiber shortening measured using implanted ultrasonic crystals. Heikkila and Nieminen[62] reported that wall thickening is preferable because of its larger signal and lower variability compared with epicardial segment shortening. The accuracy of wall thickness measurements from echocardiograms was established initially using M-mode imaging of postmortem specimens.[62] The accuracy of wall thickening measurements from 2D echocardiograms has been validated for the calculation of ventricular mass.[63] [64] Subsequently, several investigative groups demonstrated 96
the feasibility of noninvasive regional wall thickening analysis by 2D echocardiography [44] [55] , [65] [66] and explored the potential clinical usefulness of this method for diagnosis of infarction, estimation of infarct size, and assessment of recovery and response to treatment. Measurements of wall thickening obtained from analyzing 2D echocardiograms are higher than those obtained using implanted ultrasonic crystals. This discrepancy is due to placement of the crystals in the subendocardium, whose movement underestimates true endocardial excursion.[63] Implicit Assumptions
Two assumptions are made in analysis of regional wall thickening. The first assumption is that wall thickness is measured along a vector orthogonal to the myocardial wall; that is, the imaging plane should be orthogonal to the wall and thickness should be measured in a radial direction within that plane, because analysis at oblique angles overestimates wall thickness. Some investigators advocate 3D analysis to ensure orthogonality.[67] In practice, the problem of oblique imaging pertains primarily to magnetic resonance imaging and computed tomography, which image in parallel planes, rather than to echocardiography, which offers greater flexibility in selecting each imaging plane. Nevertheless, this potential source of error should not be overlooked. The second assumption is the same as for wall motion: that a one-to-one correspondence be made between points on the ventricular contour at enddiastole and at end-systole. Actually, a strict correspondence is not possible
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 24
because different slices of ventricle are imaged in systole and diastole owing to the translational motion of the heart through the imaging plane and the descent of the base toward the apex.[51] [52] However, the methods developed to date provide an estimated correspondence that has served well for both clinical and research applications. Figure 5-8 Measurement of wall thickening by the centerline method. The epicardial and endocardial contours of the left ventricular wall are displayed at end-diastole (left) and end-systole (right). Thickness is measured as the length of each of 100 chords constructed perpendicular to and evenly spaced along a line in the center of the myocardial wall (not shown), midway between the epicardial and endocardial contours. The end-diastolic endocardial contour is reproduced on the end-systolic plot to illustrate the extent of endocardial wall motion. (Redrawn from Sheehan FH, Feneley MP, DeBruijn NP, et al: J Thorac Cardiovasc Surg 1992;103:347–354.) Methods for Analyzing Regional Wall Thickening
Two methods are used for wall thickening analysis. The radial method measures wall thickness along radii extending from an origin usually located at the center of area, or at the midpoint of an anatomically defined diameter.[29] [51] [54] This method is most suitable for analyzing short-axis views with their near-circular contours, but it has also been applied to apical views.[68] In the centerline method, a centerline is drawn midway between the endocardial and epicardial contours. Wall thickness is measured along chords constructed perpendicular to and evenly spaced along the centerline (i.e., in the direction of the local radial vector[38] [69] [70] ) (Fig. 5-8) . In both methods the correspondence between end-diastole and end-systole relies on even distribution of points around the ventricular contour. No attempt has yet been made to anchor the point numbering system to available anatomic landmarks other than those used to define the start and end of the border. In short-axis views, border tracing usually begins at the junction of the right ventricle and septum, because the papillary muscles are not visible at all levels. In apical views, the border begins and ends at the valve planes. Wall thickening may be affected by cardiac motion if the wall thickness measurements are not performed independently at each time point. For example, Pandian et al[51] measured wall thickening using a radial coordinate system defined at end-diastole and superimposed on the end-
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 24
systolic contours. In a patient with marked translational motion, the origin of this coordinate system may deviate from the center of the end-systolic contour. However, these investigators measured the translation and rotation of short-axis "slices" and found that the mean rotation in their 12 normal subjects was 1.0 ± 7.6 degrees counterclockwise, and translation averaged 1.7 ± 21.4 mm to the right and 6.7 ± 37 mm anteriorly. Realignment to correct for translation and rotation did not alter the mean or range of normal thickening.[51] Force 97
et al[54] reported that rotation in the dog averages 3.5 degrees and also recommended against corrective realignment. However, it is not clear how much translation affects wall thickening measurements in patients with diseased hearts. Comparison of Wall Motion and Wall Thickening Several studies have been performed that compare wall motion, wall thickening, and other parameters. Because no test has yet been developed for anatomic validation of methods for wall motion analysis, the comparisons with wall thickening have used empirical criteria. In deciding between these two parameters, theoretical and practical considerations are also worthy of attention. Theoretical Considerations
When the left ventricle is modeled as a thick-walled cylinder contracting radially and longitudinally, it can be shown mathematically that wall thickening, midwall shortening, and longitudinal axis shortening are related, but internal radius shortening (i.e., wall motion) is significantly influenced by the degree of left ventricular hypertrophy.[71] In ventricles with normal wall thickness, wall motion and wall thickening correlate closely.[72] However, the relative contribution of wall thickening, but not of wall motion, to ventricular power during ejection increases with increasing hypertrophy.[73] Thus, for example, wall motion may be inappropriately elevated in patients with hypertrophy owing to chronic valvular disease or cardiomyopathy. The discordance between wall motion and either wall thickening or midwall fiber shortening, both of which do not display hyperkinesis in these patients, is related to the relative wall thickness (compared with the chamber radius).[71] [74] [75] Thus, analysis of regional wall thickening more accurately reflects the functional status of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 24
hypertrophied ventricles than does endocardial wall motion. TABLE 5-3 -- Heterogeneity of Wall Motion and Wall Thickening in Normal Subjects *
N 10 10 12 12 12 10 14 14 14 9 9 9 9
% Wall % Wall Motion Thickening MEAN COEF. MEAN COEF. ± SD OF VAR. ± SD OF VAR. Reference Method View Hemiaxis SAX 30 ± 7 0.29 — — Moynihan shortening mitral et al[29] Hemiaxis SAX 35 ± 0.36 — — Moynihan shortening papillary 13 et al[29] Radius SAX 44 ± 0.39 52 ± 0.52 Pandian et shortening mitral 17 27 al[51] Radius SAX 49 ± 0.39 53 ± 0.43 Pandian et shortening chordal 19 23 al[51] Radius SAX 53 ± 0.34 53 ± 0.45 Pandian et shortening papillary 18 24 al[51] Radius SAX 24 ± 5 0.21 18 ± 0.72 Sandor et shortening papillary 13 al[76] Area change SAX 39 — — — Haendchen mitral et al[78] Area change SAX 56 — — — Haendchen papillary et al[78] Area change SAX 61 — — — Haendchen apical et al[78] Area change SAX 61 ± 0.16 38 ± 0.45 Ren et al[77] mitral 10 17 Area change 4CH: 69 ± 0.23 37 ± 0.38 Ren et al[77] apex 16 14 Area change 4CH: 62 ± 0.26 25 ± 0.40 Ren et al[77] postlateral 16 10 Area change 4CH: 70 ± 0.19 35 ± 0.43 Ren et al[77] septum 13 15
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 15 di 24
4CH, apical four chamber; Coef. of Var., coefficient of variation (calculated as standard deviation/mean); N, number of subjects; SAX, short axis; SD, standard deviation. *Table displays representative data only from cited references; for complete data, see reference.
In addition to being independent of the degree of hypertrophy, wall thickening analysis is independent of translational artifact; therefore, no empirical realignment needs to be performed to correct for cardiac translation or rotation, and patients can be evaluated serially before and after bypass surgery without having to adjust for the effect of pericardiectomy on septal motion. The disadvantage of measuring wall thickening is that it does not reflect the contribution of epicardial motion to stroke volume.[57] Practical Considerations
Wall thickening analysis requires delineation of the epicardial contours as well as the endocardial contours. This doubling of work is not merely time consuming but also introduces additional opportunity for error. Imaging must be performed with the intent to quantify regional wall thickening, so that care is taken to include the epicardium within the scan sector throughout the cardiac cycle. Empirical Comparisons
The final arbiter between wall motion and wall thickening, each with its theoretical advantages and practical disadvantages, is performance. Because diagnostic accuracy is intimately related to normal variability, several investigators have performed comparative studies (Table 5-3) .[29] , [51] [69] [76] [77] [78] In general, although both akinesis and the absence of wall thickening are rare in normal subjects, wall thickening is more heterogeneous (i.e., has a higher coefficient of variation). The normal range, defined as mean ± 2 standard deviations, is more likely to encompass 0% thickening than 0% motion. The higher wall thickening variability is due in large part to point-to-point differences in end-diastolic wall thickness and can be reduced by using the end-diastolic perimeter length to normalize the observed change in wall thickness.[69]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 16 di 24
In diagnosing myocardial infarction, both parameters perform well (see "Diagnosis of Myocardial Infarction" 98
and "Assessment of Infarct Size"). Wall motion is slightly more sensitive in detecting dysfunction (96% vs. 93%), and wall thickening is slightly better in identifying normally functioning regions (100% vs. 83%) (Table 5-4) . In clinical studies, wall thickening has proved to be more sensitive in detecting dysfunction.[77] [79] For estimation of infarct size, both parameters yield comparable results (Table 5-5) . Tissue Doppler Imaging of Myocardial Velocity Low-velocity Doppler signals returned by myocardial tissue can be analyzed to assess regional ventricular function without the need for border delineation. [80] The velocities are presented visually using color coding, but they can also be quantified. The M-mode format provides higher temporal resolution. For accuracy 2D tissue Doppler imaging should be performed at a frame rate fast enough to capture changes in velocity.[80] Although it is a form of mapping rather than imaging, the pulsed wave Doppler mode allows peak velocity to be measured with high temporal and spatial resolution within the sample volume.[81] The accuracy of velocity measurements by tissue Doppler imaging has been validated in phantoms against M-mode echocardiography, in experimental animals by comparison with sonomicrometry, and in normal subjects versus M-mode.[80] [82] [83] The artifactual velocity contributed by the heart's translational motion can be canceled by computing a myocardial velocity gradient as the difference TABLE 5-4 -- Accuracy of Regional Systolic Function Analysis in Dia Myocardial Infarction Diagnosis Study Group Human: 37 acute MI Human:
Locatio SENSITIVITY SPECIFICITY Accurac Method Threshold (%) (% (%) Semiquantitative Abnormal 100 — 9
Semiquantitative Hypo, ak,
—
—
9
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
26 TMMI, 6 SEMI Human: 66 acute MI Human: 20 MI, 18 normal Human: 20 MI, 18 normal Human: 20 MI, 18 normal Human: 15 MI Human: 48 acute MI Human: 18 angina, 12 SEMI Human: 18 angina, 12 SEMI Human: 32 angina, 33 acute MI Dog: 27 Dog: 27
Pagina 17 di 24
dys
Semiquantitative Hypo, ak, dys
—
—
9
Area change
<2 SD
95
89
—
Hemiaxis shortening
<2 SD
85
78
—
Perimeter shortening
<2 SD
90
72
—
Semiquantitative Hypo, ak, dys Semiquantitative Hypo, ak, dys
90
54
—
—
—
9
Semiquantitative Akinesis
50
100
—
Semiquantitative Severe hypo
83
100
—
Semiquantitative Abnormal
94
84
—
Area change
<2 SD
77
83
7
Wall thickening <2 SD
81
100
8
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 18 di 24
— Human: 9 Wall motion <2 SD 100 — TMMI 6 Wall motion <2 SD 33 — — SEMI 9 Wall thickening <2 SD 89 — — TMMI 6 Wall thickening <2 SD 83 — — SEMI 6 Epicardial <2 SD 0 — — SEMI motion Human: Semiquantitative Hypo, ak, 94 — 9 95 acute dys MI Human: Semiquantitative Hypo, ak, 100 — — 31 TMMI dys 9 Semiquantitative Hypo, ak, 56 — — SEMI dys Dog: 24 Wall thickening ≤0 71 100 — MI, 5 nl Dog: 24 Wall motion ≤0 63 80 — MI, 5 nl Human: Semiquantitative Hypo, ak, 100 — 9 32 acute dys MI Human: Semiquantitative Hypo, ak, — — 8 73 TMMI dys Human: Semiquantitative Hypo, ak, 93 — 7 92 acute dys MI ak, akinesis; dys, dyskinesis; hypo, hypokinesis; MI, myocardial infarctio normal; SD, standard deviation; SEMI, subendocardial MI; TMMI, transmu between the endocardial and epicardial velocities normalized by the local wall thickness. [84] This correction, however, can only be applied to the anterior and posterior segments in the parasternal short-axis view, whose motion parallels the direction of the ultrasound beam.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 19 di 24
The normal range differs between the base and apex, the anterior and posterior walls, and the endocardium, midwall, and epicardium regardless of whether it is measured in M-mode as a tissue velocity, in 2D as a myocardial velocity gradient, or by pulsed wave Doppler as a peak velocity.[84] [85] [86] Variability is not lower than for other echocardiographic indices of ventricular function.[87] Several clinical applications have been proposed[88] even though the technology is limited to ventricular segments lying within ± 15 degrees of the incidence angle. In apical views, tissue Doppler imaging captures only longitudinal shortening. Tissue velocities measured from the apex failed to correlate with visual wall motion scores in infarct patients, although the velocity gradient between base and apex did reflect the number of dysfunctional segments. [89] A more recent study indicated that velocity measurement by pulsed Doppler improves diagnostic accuracy of viability assessment by dobutamine stress echocardiography.[90] In contrast, another study found this mode unable to discriminate control versus scar tissue when systolic velocity was measured, although diastolic velocities proved to be useful. [91] Clinical acceptance of tissue Doppler imaging is currently inhibited by the lack of consensus or standardization among the various acquisition and quantification modes. This modality's greatest contribution may be to applications for which it offers unique information. For example, 2D tissue Doppler acceleration 99
TABLE 5-5 -- Evaluation of Myocardial Infarction by Two-Dimensio Study No. of Echo Group Subjects Timing View Method Estimation of infarct size Dog 25 5.5 hr 1 Semiquant LAX +3 SAX Human 20 2–4 4 Semiquant days SAX Human 29 2–4 4 Semiquant days SAX
Infarct Size Threshold Parameter Hypo, ak, Tc99 dys
Hypo, ak, Thallium 201 dys Hypo, ak, Tc99 dys
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 20 di 24
Human
60
Human
15
Human
48
Dog
20
Dog
20
Dog
24
Dog
24
Dog
27
Dog
27
Dog
10
Human
61
Dog
11
Human
20
<12 hr 3 LAX +5 SAX Varied 3 SAX <12 hr 3 apical 2 hr 1 LAX +3 SAX 48 hr 1 LAX +3 SAX 20 min 2 SAX 2 days 2 SAX Varied 3 SAX Varied 3 SAX 6 hr 4 SAX <12 hr 4 LAX +3 SAX 6 hr 3 SAX +3 apical <1 yr 3 SAX
Semiquant
Hypo, ak, Peak CK-MB dys
Semiquant
Ak, dys
Semiquant
Hypo, ak, Peak CK-MB dys <0 Histopatholog
Wall thickening
Postmortem
Wall thickening
<0
Histopatholog
Wall thickening Wall thickening Area change
<0
Histopatholog
<0
Histopatholog
<2 SD
Histopatholog
Wall thickening Semiquant
<2 SD
Histopatholog
Semiquant
Hypo, ak, Peak CK dys
Semiquant; endocardial surface map
Abnormal Histopatholog
Semiquant; endocardial
Abnormal Postmortem
Abnormal Histopatholog
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 21 di 24
+ 2 surface map apical Dog 10 72 hr 5 Radial SAX shortening at ES Dog 10 72 hr 5 Radial SAX shortening over cardiac cycle Correlation with the size of the risk region Dog 24 20 min 2 Wall SAX thickening Dog 24 2 days 2 Wall SAX thickening Dog 10 6 hr 4 Semiquant SAX Dog 11 3 hr 4 Wall motion SAX Dog 11 3 hr 4 Wall motion SAX Dog 11 3 hr 4 Circumference SAX Dog 11 3 hr 4 Wall motion SAX over cardiac cycle Wall Dog 12 2 hr 1 SAX thickening: referenced to contrast defect Dog 12 2 hr 1 Wall SAX thickening: COM method
<15%
Histopatholog
<15%
Histopatholog
<0
Angiography
<0
Angiography
Abnormal Echo contrast <10%
Echo contrast
<20%
Echo contrast
Ak, dys
Echo contrast
<95% CI
Echo contrast
<95% CI
Echo contrast
<95% CI
Echo contrast
Risk Study No. of Echo Group Subjects Timing View Method
Infarct Size Threshold Parameter ESTIM
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Dog
Pagina 22 di 24
18
60 min 1 Wall <95% CI Microsphere SAX thickening Dog 16 60 min 1 Wall <2 SD Microsphere SAX motion Dog 16 60 min 1 Wall <95% CI Microsphere SAX motion Dog 16 60 min 1 Wall Dys Microsphere SAX motion Dog 16 60 min 1 Wall <2 SD Microsphere SAX thickening Wall <95% CI Microsphere Dog 16 60 min 1 SAX thickening Dog 16 60 min 1 Wall Dys Microsphere SAX thickening ak, akinesis; CI, confidence interval; CK, creatine kinase; CK-MB, creati COM, center of mass (method of realignment for translation); Corr. Coef., c dys, dyskinesis; ES, end-systole; hypo, hypokinesis; LAX, long axis; SAX, deviation; SEE, standard error of estimate; semiquant, semiquantitative anal Tc 99m pyrophosphate scintigraphy. * Percentage circumference.
100
imaging can localize the onset of mechanical contraction for electrophysiology testing. [92] Epicardial Motion The motion of the epicardium can be measured as a parameter of regional systolic function by applying methods for wall motion analysis to the epicardial contour. Compared with endocardial motion, however, epicardial motion is much lower in magnitude,[76] [78] [79] because thickening of the wall during systole contributes about half of what is measured as endocardial displacement.[93] Because measurement of epicardial motion is subject to the same sources of error and variability as endocardial motion, its lower
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 23 di 24
magnitude results in an unfavorably high coefficient of variation,[76] which may explain its low sensitivity in detecting the presence of myocardial infarction.[79] Shape Analysis It has long been established that the left ventricle becomes more spherical when it dilates and decompensates.[94] [95] This compensatory mechanism allows a more even distribution of regional stress and improves ventricular efficiency. More recently it has been recognized that similar changes occur on a regional level in patients with recent myocardial infarction. Measurement of the magnitude of these changes provides information on the mechanism, magnitude, and time course of remodeling and its effect on prognosis. Global Shape
The analysis of global left ventricular shape is performed using general mathematical models. Most commonly, the ventricle is assumed to be elliptic, and its degree of sphericity is assessed by determining the ratio of the long-axis length to the short-axis diameter.[96] This parameter is subject to variability in measuring the axis lengths. Other parameters of global shape have also been developed, such as the ratio of the end-diastolic volume to the volume of a sphere with equivalent long-axis length, the ratio of the end-diastolic volume to the volume of the sphere with equivalent surface area, or the following ratio[97] [98] [99] 4π(Area)/(Perimeter2 ) In an experimental heart failure model, shape measurements based on axis length and area-to-perimeter ratios were less sensitive to incipient ventricular decompensation than the volume-to-surface area ratio.[99] Regional Shape
In patients with regional dysfunction (e.g., secondary to myocardial infarction), the left ventricular contour may develop regional abnormalities in curvature. [97] Curvature is a major determinant of wall tension, and changes in ventricular shape have been attributed to acute elevation in stress at the time of infarction; remodeling redistributes these stresses to improve efficiency. [100] [101] Analysis of regional curvature has been shown to provide diagnostic information when measured from contrast
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 24 di 24
ventriculograms.[102] However, relatively little investigation has been performed in measuring regional curvature from 2D echocardiograms. [103] This lack of investigation may be because the apparent shape of the left ventricle in 2D echocardiography is greatly influenced by the imaging plane and is therefore dependent on the skill and care of the sonographer acquiring the images. It may be preferable, when analyzing echocardiograms, to measure regional shape using a method that is relatively insensitive to oblique imaging. One approach is to compare the lengths of the contour segments between the papillary muscles in the shortaxis view (Fig. 5-9) . This simple but effective method has proved useful for studying ventricular remodeling in patients with myocardial infarction. [104] Expansion (lengthening) of the infarct region is accompanied by thinning of the myocardium; therefore, the ratio of wall thickness in the diseased and normal regions provides another parameter of left ventricular geometry.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/41.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 8
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Imaging and Image Analysis for Quantification Image Acquisition Technique
Unlike contrast ventriculography, in which the view angles are fixed, 2D echocardiography relies on the skill Figure 5-9 Method of measuring the expansion index and thinning ratio, shown in a midventricular section from a patient with anterior infarction and asynergy. Segment lengths were measured between midpoints of papillary muscle landmarks. a, average thickness of asynergic zone; b, average thickness of nonasynergic zone; LV, left ventricle; RV, right ventricle; x, endocardial length of asynergy-containing segment; y, endocardial length of segment without asynergy. Expansion index, x/y; thinning ratio, a/b. (Copyrighted and reprinted with the permission of Clinical Cardiology Publishing Company, Inc., and/or the Foundation for Advances in Medicine & Science, Inc. From Jugdutt BI, Michorowski BL: Clin Cardiol 1987;10:641–652.)
101
of the sonographer in locating the desired anatomic slice in each patient. It is important to locate the various "standard" views with precision, reduce heterogeneity in the normal population, enhance diagnostic accuracy, and reduce variability between repeated studies in the same patient. The quality of quantitative analysis improves if the person performing image acquisition also performs the analysis. A sonographer with experience in quantification can recognize images that will be difficult to analyze and will enhance them as much as possible during acquisition. The American Society of Echocardiography has published recommendations concerning imaging for quantitative analysis of the endocardial contour. [2]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 8
Additional attention also may be needed to ensure visualization of the epicardium (e.g., increasing depth to ensure that the epicardium and anatomic landmarks are visible within the sector scan throughout the cardiac cycle and increasing lateral gain to improve edge definition along walls parallel to the beam). In patients with poor endocardial edge definition, intravenous injection of a contrast agent (e.g., albumin microbubbles) opacifies the chamber and improves endocardial depiction. [105]
An electrocardiographic rhythm strip should be acquired and recorded with the image to facilitate selection of a normal sinus beat (not following a premature beat) for analysis. Analog versus Digital Imaging
Echocardiograms are traditionally recorded on videotape at 30 frames per second. Because of the nature of analog imaging, only half of the scan lines are laid down at this rate; the other half of the lines, which alternate between the first set, are recorded 1/60 second later. Thus, each image frame consists of two half-resolution fields offset by 1/60 second. In analog-to-digital conversion, the convention is to treat each frame as a single image, regardless of the component fields. Digital images have a resolution of 256 × 256 or 512 × 512 pixels. Using the higher format retains the original image's resolution, but it requires four times as much computer memory. In practice, digitization at the 256 × 256 pixel resolution produces acceptable results. Digitization is necessary for quantitative analysis and facilitates comparison of serial studies.[106] As the speed of computer workstations increases and the price of digital memory decreases, the use of digital imaging will increase to take advantage of these benefits. This scenario is best exemplified by imaging systems intended for exercise echocardiography, which acquire and display up to four cine loops at a time, so that small changes in wall motion can be more easily appreciated. The same technology can be used to compare serial studies on the same patient. Networking between computers will allow images to be accessed from different locations in the hospital. Indeed, it may be possible in the near future to transmit and receive cardiac images over long distances for consultations. Image Analysis
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 8
Frame Selection
When the objective is to select a representative cardiac cycle of images for quantitative analysis, the principal consideration is to find a beat in which the endocardial and epicardial contours are clearly visible throughout the cardiac cycle. In general, images acquired near end-expiration are clearer because there is less respiratory motion artifact and less lung interposition between the transducer and the heart. During inspiration, the beat-to-beat variability is higher than at end-expiration, especially at the apex (Fig. 510) .[107] The electrocardiographic rhythm strip assists in selecting a normal sinus beat or a beat of average RR interval in patients with atrial fibrillation. The end-diastolic frame is that with maximum cavity area and generally lies on or one frame after the R wave. The end-systolic frame is that with minimum cavity area. Identification of end-systole may be difficult in patients with asynchronous wall motion, because the timing of minimum cavity area may differ between views. End-systole can be identified from the second heart sound if a phonocardiogram is recorded during imaging. [108] Alternatively, the average time of minimum cavity area can be determined from reviewing all views and then applied to each view by noting its timing on the electrocardiogram. Border Tracing
The objective of border tracing is to delineate the left ventricular endocardial and epicardial contours. The endocardial edge is the interface between the bright echoes at the edge of the myocardium and the darker region of the ventricular cavity. Deciding where the endocardium lies among the bright echoes may be difficult, particularly when the contour is roughened by trabecular reflections. Contributing to the roughness is the relatively poorer resolution parallel to the echo beam. Studies in postmortem hearts have shown that tracing the leading edge of the endocardial echoes reduces underestimation of the cavity area compared with tracing the innermost black-white border.[109] In practice, this approach is associated with unacceptable variability, because the leading edge of the wall nearest to the transducer is separated from the trailing edge at the lumen by the bright border pixels.[109] [110] Some investigators suggest that the trailing edge of the nearer wall be traced and then corrected using image processing techniques to approximate the leading edge. [110] Along walls parallel to the echo beam, phantom studies have shown that accuracy is greatest when the midpoint of the leading edge is traced.[109]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 8
By convention, the papillary muscles are included in the cavity (Fig. 5-11) . It is recommended that the trabeculae also be included in the cavity, for two reasons. First, this is the approach used for analyzing contrast ventriculograms, which have a high accuracy for volume determination.[111] Indeed, the reported underestimation of volume by 2D echocardiography techniques may be related in part to inclusion of trabeculae with the myocardium in 102
Figure 5-10 Variability in the analysis of regional wall motion. Top, The effect of respiration on variability in 10 normal subjects. The regional ejection fraction between two consecutive beats from an inspiratory phase (variability Insp) is compared with the variability between two beats from the end-expiratory phase of two consecutive respiratory cycles (variability Exp). The variability is expressed as the mean of the absolute differences. In addition, the mean values for regional ejection fraction are presented from the second of the two consecutive beats from the inspiratory phase (mean Insp) and from an end-expiratory phase (mean Exp). Bottom, Variability in regional left ventricular function as measured at end-expiration in 20 normal subjects. The intraobserver, interobserver, and interbeat variability in regional ejection fraction are expressed as the mean of the absolute differences. In addition, the 10th to 90th percentile range for the regional ejection fraction in normal subjects is presented. Note that the interbeat variability is comparable to the intraobserver and interobserver variability. REF, regional ejection fraction. (From Assmann PE, Slager CJ, van der Borden SG, et al: J Am Soc Echocardiogr 1990;3:478–487.)
earlier studies.[112] Second, the borders traced for volume analysis can be applied to analysis of regional function as well. If trabeculae are traced, the borders of the endocardium are extremely noisy, and the resulting measurements of wall motion or wall thickening suffer from wide point-topoint variability. Some automated border detection programs have been developed. [113] As these methods become available commercially, it is important to remember that the physician ultimately must take responsibility for verifying that the border is drawn correctly. One image processing technique does not attempt to define a continuous endocardial contour such as a human observer would trace, but rather detects all blood-tissue interfaces lying within a user-defined region of interest.[114] Because the process can be performed in real time, the displacement of the interfaces through the cardiac cycle can be computed. Using color coding, an image is generated
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 8
representing regional wall motion.[115] The method has been validated for measurement of volume and ejection fraction; for wall motion assessment its segmental analysis does not differ more from the consensus of two human observers than the humans do from each other.[115] Assistance from Digital Workstations
Digital workstations were initially developed for acquisition and display of image loops for exercise echocardiogram interpretation. With the increased interest in quantitation, workstation software is currently available for reviewing images and tracing the borders of the left ventricle and other structures. A properly programmed digital workstation can assist image analysis in a number of ways.
103
Figure 5-11 (color plate.) Border tracing. In the initial tracing of the endocardial contour, the papillary muscles are included with the chamber, which produces a smooth contour for analyzing wall motion and wall thickening. Then the papillary muscle borders are traced separately and can be inserted for calculation of left ventricular volume. The epicardial contour is also shown. Cine Loop.
Few images are of such high quality that they can be analyzed entirely from a single stopped frame; therefore, it is essential to be able to review the full cardiac cycle in cine loop format, because watching wall motion helps to identify the endocardial and epicardial borders. The ability to watch wall motion is particularly important in analyzing images of borderline quality. Sometimes it is helpful to toggle quickly between the frame being analyzed and the preceding or following frame to look for a flash of movement that might help to identify an elusive border. Having control over the gray scale and contrast level also may assist in identifying a dim border segment. Review of the cine loop should be available not only before tracing but also during tracing so that the border can be traced in segments as they are identified. Cine loop review is also needed to double-check the tracing, which is most easily accomplished by alternately hiding and displaying the border while viewing the images. Tracing and Editing.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 8
There are two main methods of tracing: continuous drawing and dot entry. Continuous drawing allows direct delineation of complex border shapes, but it requires good hand-eye coordination. With dot entry, the spaces between the dots are filled in using spline curves. Dot entry is easier for the user and faster over regions that have a simple shape. However, in highly curved regions, the spline curve may not put the border where it was intended; in this case, the border would need to be edited. The workstation software should allow editing of any part of the traced border. Programs that allow selected border segments to be stretched in or out to a new position ("rubber banding") are easier to use than programs that delete the border segment and redraw it, because the latter requires more steps, and connecting the new segment smoothly to the raw ends of the remaining original border is difficult. As a final check, the observer should turn off the border overlay, review the cine loop again, and then turn the overlay back on to confirm the accuracy of the border placement. A custom program developed at the University of Washington allows the user to enter additional points on the border to demarcate segments whose definition is of low confidence. This customized option may help in the subsequent data interpretation. These warning points can also be used to omit the affected segments from regional function analysis. The ability to retain partial borders for analysis makes maximum use of the data by reducing the number of patients whose studies are rejected. The use of digital workstations does not reduce the fatigue associated with image analysis. Paying careful attention to details such as ambient lighting, ergonometrically sound furnishings, and periodic rest periods helps to maximize observer attention to detail and improve accuracy. Because of the possibility of fatigue, observers should not trace more than four hours per day on a regular basis. Variability Many factors affect the accuracy of quantitative image analysis and the precision or repeatability of a measurement. One must be aware of these sources of variability so that measures can be taken to minimize their impact. Beat-to-Beat Variability
Because patients are living, breathing subjects, there is variability between
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 8
different cardiac cycles. This variability can be minimized by averaging over multiple consecutive cardiac cycles. Sandor et al[76] reported that threebeat averaging reduced the normal standard deviation for wall motion and wall thickening by 34% and 38%, respectively. Variability is higher during inspiration than expiration; end-expiratory cardiac cycles are least subject to motion artifact (see Fig. 5-10) . [107] Intraobserver and Interobserver Variability
In general, variability is higher for wall thickening than wall motion.[51] [69] [77] This difference is due mostly to point-to-point variability in enddiastolic wall thickness, because normalization of thickness change by enddiastolic perimeter length reduces variability to that of wall motion.[69] Variability in measuring wall thickening can also be reduced if thickness change is normalized by the end-diastolic wall thickness computed over a local region rather than at a discrete point on the ventricular contour.[70] The magnitude of inter- and intraobserver variability is low, ranging from 5% to 10% of the mean measurement for both wall motion and wall thickening, and it is not significantly higher than the variability between consecutive cardiac cycles (see Fig. 5-10) .[57] [77] , [107] [116] Pandian et al[51] reported intraobserver variability exceeding 50% of the mean for wall thickening, perhaps because the 104
beat and frame selection were not held constant between repeated tracings. Variability in measuring regional function is highest at the apex.[52] Pertinent to methods that use a coordinate system based on anatomic landmarks, the intra- and interobserver variability for landmark identification is 4.4% and 3.5% of the ventricular circumference, respectively.[44] Study-to-Study Variability
Echocardiography is the imaging modality most suitable for serial studies (e.g., to follow a patient's response to treatment), because it is safe, portable, and inexpensive. Study-to-study variability is low for 2D echocardiography, ranging from 7% to 15%.[16] [56] Some of the contributing factors cannot be controlled, such as changes in hemodynamic or emotional state. In stable patients, however, day-to-day changes in heart rate and blood pressure are small and do not significantly affect measurement of the ejection fraction.[117] Variability is 5% between studies acquired by different
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 8
sonographers but analyzed by the same observer, which is lower than the 7% variability for images acquired by the same sonographer but analyzed by different observers.[117]
MD Consult L.L.C. http://www.mdconsult.com /das/book/view/26040709/1031/42.html/top Bookmark URL:
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Research Applications Two-dimensional echocardiography is particularly useful as a research tool because of its large informational content. Regional function can be assessed qualitatively or measured quantitatively in terms of endocardial wall motion, wall thickening, or epicardial motion. From wall thickness measurements it is possible to measure mass, wall stress, and even regional stroke work, a parameter of local oxygen consumption.[165] To this list can be added 108
measurement of left ventricular shape, a major determinant of stress and function. The ability to clearly visualize the valve allows assessment of the relationship between valvular and ventricular function.[166] [167] [168] Frameby-frame analysis can be performed to analyze the synchrony of regional function through the cardiac cycle.[116] [169] By infusing echo contrast or performing tissue characterization analysis, the functional status of the myocardium can be related to its perfusion and pathology.[170] [171] By incorporating knowledge of spatial position and orientation of imaging planes, the 2D data can be used to create 3D reconstructions of the left ventricle,[172] which provide a more comprehensive view of this complex organ and allow for more detailed and accurate analysis of spatial relationships. Thus, left ventricular volume can be measured without geometric assumptions concerning its shape, wall thickness can be measured without error from oblique imaging, and shape can be better appreciated in three dimensions. These tools facilitate research to improve understanding of the pathophysiology of the disease process, the mechanisms by which the left ventricle attempts to compensate, and the beneficial effect of therapeutic interventions. However, it is important for investigators interested in applying these techniques to understand the limitations of the method as
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
well as its potential benefits. It is generally known that spatial resolution within the imaging plane is higher in the direction of the echo beam than parallel to it. It is equally important to understand that spatial resolution is lowest orthogonal to the imaging plane: the so-called slice thickness owing to finite beam width causes inaccuracy in delineating complex curved surfaces.[173] [174] The temporal resolution, up to 30 frames per second, allows for comparisons of end-diastole to end-systole and analysis of asynchrony,[116] [169] but it may not be adequate for patients with high heart rates (e.g., infants). Two-dimensional echocardiography has been used to acquire the end point measurements in several clinical trials. For example, echocardiographic assessment of wall motion was performed to evaluate functional recovery after angioplasty or thrombolytic therapy for acute myocardial infarction and after coronary artery bypass surgery for angina.[17] [175] [176] [177] Other applications are to test drugs for side effects and to study the effects of anesthetics and surgical procedures.[178] [179] In general, however, echocardiography has not been considered the imaging modality of choice for clinical trials. This fact may be due to poor echogenicity in up to 25% of patients, usually as a result of coexistent lung disease. Another reason may be the reliance on skill, training, and reproducibility of sonographers in acquiring images in comparable imaging planes between patients. New technologic advances in imaging equipment may alleviate this problem in the future, for example, by displaying the position of each imaging plane online to actively assist in properly orienting each acquisition.[180] [181] [182] These sources of data loss and variability are greater than for other imaging modalities, but they are more than compensated for by the much greater informational content of echocardiographic examinations. It can be anticipated that echocardiography will be increasingly employed for clinical investigation in the future.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/44.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 18
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
References 1. Edwards WD, Tajik AJ, Seward JB: Standardized nomenclature and anatomic basis
for regional tomographic analysis of the heart. Mayo Clin Proc 1981;56:479–497. 2. Schiller, NB, Shah PM, Crawford M, et al: Recommendations for quantitation of the
left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of TwoDimensional Echocardiograms. J Am Soc Echocardiogr 1989;2:358–367. 3. Herman MV, Gorlin R: Implications of left ventricular asynergy. Am J Cardiol
1969;23:538–547. 4. Gibson RS, Bishop HL, Stamm RB, et al: Value of early two dimensional
echocardiography in patients with acute myocardial infarction. Am J Cardiol 1982;49:1110–1119. 5. Stamm RB, Gibson RS, Bishop HL, et al: Echocardiographic detection of infarct-
localized asynergy and remote asynergy during acute myocardial infarction: Correlation with the extent of angiographic coronary disease. Circulation 1983;67:233–244. 6. Bourdillon PDV, Broderick TM, Sawada SG, et al: Regional wall motion index for
infarct and noninfarct regions after reperfusion in acute myocardial infarction: Comparison with global wall motion index. J Am Soc Echocardiogr 1989;2:398–407. 7. Kisslo J, Robertson D, Gilbert B, et al: A comparison of real-time, two-dimensional
echocardiography and cineangiography in detecting left ventricular asynergy. Circulation 1977;55:134–141. 8. Ohuchi Y, Kuwako K, Umeda T, Machii K: Real-time, phased-array, cross-sectional
echocardiographic evaluation of left ventricular asynergy and quantitation of left ventricular function: A comparison with left ventricular cineangiography. Jpn Heart
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 18
1980;21:1–15. 9. Hecht HS, Taylor R, Wong M, Shah PM: Comparative evaluation of segmental
asynergy in remote myocardial infarction by radionuclide angiography, twodimensional echocardiography, and contrast ventriculography. Am Heart J 1981;101:740–749. 10. Freeman AP, Giles RW, Walsh WF, et al: Regional left ventricular wall motion
assessment: Comparison of two-dimensional echocardiography and radionuclide angiography with contrast angiography in healed myocardial infarction. Am J Cardiol 1985;56:8–12. 11. Shiina A, Tajik AJ, Smith HC, et al: Prognostic significance of regional wall
motion abnormality in patients with prior myocardial infarction: A prospective correlative study of two-dimensional echocardiography and angiography. Mayo Clin Proc 1986;61:254–162. 12. Lundgren C, Bourdillon PDV, Dillon JC, Feigenbaum H: Comparison of contrast
angiography and two-dimensional echocardiography for the evaluation of left ventricular regional wall motion abnormalities after acute myocardial infarction. Am J Cardiol 1990;65:1071–1077. 13. Ginzton L, Conant R, Brizendine M, et al: Exercise subcostal two-dimensional
echocardiography: A new method of segmental wall motion analysis. Am J Cardiol 1984;53:805–811. 14. Bhatnagar SK, Al-Yusuf AR: Significance of early two-dimensional
echocardiography after acute myocardial infarction. Int J Cardiol 1984;5:575–84. 15. Loh IK, Yzhar C, Beeder C, et al: Early diagnosis of nontransmural myocardial
infarction by two-dimensional echocardiography. Am Heart J 1982;104:963–968. 16. Deutsch HJ, Curtius JM, Leischik R, et al: Reproducibility of assessment of left
ventricular function using intraoperative transesophageal echocardiography. Thorac Cardiovasc Surg 1993;41:54–58. 17. Otto C, Stratton JR, Maynard C, et al: Echocardiographic evaluation of segmental
wall motion early and late after thrombolytic therapy in acute myocardial infarction: The Western Washington Tissue Plasminogen Activator Emergency Room Trial. Am J Cardiol 1990;65:132–138. 18. Chaitman BR, DeMots H, Bristow JD, et al: Objective and subjective analysis of
left ventricular angiograms. Circulation 1975;52:420–425.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 18
19. Wexler LF, Lesperance J, Ryan TJ, et al: Interobserver variability in interpreting
contrast left ventriculograms (CASS). Cathet Cardiovasc Diagn 1982;8:341–355. 109
20. Lazar HL, Plehn JF, Schick EM, et al: Effects of coronary revascularization on
regional wall motion. J Thorac Cardiovasc Surg 1989;98:498–505. 21. Kan G, Visser CA, Koolen JJ, Dunning AJ: Short and long term predictive value of
admission wall motion score in acute myocardial infarction. A cross sectional echocardiographic study of 345 patients. Br Heart J 1986;56:422–427. 22. Nixon JV, Narahara KA, Smitherman TC: Estimation of myocardial involvement
in patients with acute myocardial infarction by two-dimensional echocardiography. Circulation 1980;62:1248–1255. 23. Horowitz RS, Morganroth J, Parrotto C, et al: Immediate diagnosis of acute
myocardial infarction by two-dimensional echocardiography. Circulation 1982;65:323–329. 24. Gibson DG, Prewitt TA, Brown DJ: Analysis of left ventricular wall movement
during isovolumic relaxation and its relation to coronary artery disease. Br Heart J 1976;38:1010–1019. 25. Goodyear AVN, Langou RA: The multicentric character of normal left ventricular
wall motion. Implications for the evaluation of regional wall motion abnormalities by contrast angiography. Cathet Cardiovasc Diagn 1982;8:225–232. 26. Ginzton LE, Berntzen R, Lobodzinski S, et al: Computerized quantitative segmental wall motion analysis during exercise: Radial vs. centerline left ventricular segmentation. In Ripley KL (ed): Computers in Cardiology. Long Beach, Calif, IEEE Computer Society, 1985, pp 157–160. 27. Rein A, Sapoznikov D, Lewis N, et al: Regional left ventricular ejection fraction
from real-time two-dimensional echocardiography. Int J Cardiol 1982;2:61–70. 28. Assmann PE, Slager CJ, van der Borden SG, et al: Comparison of models for
quantitative left ventricular wall motion analysis from two-dimensional echocardiograms during acute myocardial infarction. Am J Cardiol 1993;71:1262– 1269.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 18
29. Moynihan PF, Parisi AF, Feldman EL: Quantitative detection of regional left
ventricular contraction abnormalities by two-dimensional echocardiography: I. Analysis of methods. Circulation 1981;63:752–760. 30. Slager CJ, Hooghoudt TEH, Serruys PW, et al: Quantitative assessment of regional
left ventricular motion using endocardial landmarks. J Am Coll Cardiol 1986;7:317– 327. 31. Caiani EG, Cerutti S: Analysis of left ventricular wall motion using dynamic
alignment. Comput Cardiol 2000 (in press). 32. Ingels NB Jr, Mead CW II, Stinson EB, Alderman EL: A new method for
assessment of left ventricular wall motion In Ripley KL, Ostrow HG (eds): Computers in Cardiology. Long Beach, Calif, IEEE Computer Society, 1978, pp 57–61. 33. Homans DC, Sublett E, Lindstrom P, et al: Subendocardial and subepicardial wall
thickening during ischemia in exercising dogs. Circulation 1988;78:1267–1276. 34. Young AA, Kramer CM, Ferrari VA, et al: Three-dimensional left ventricular
deformation in hypertrophic cardiomyopathy. Circulation 1994;90:854–867. 35. Gibson DG, Sanderson JE, Trail TA, et al: Regional left ventricular wall movement
in hypertrophic cardiomyopathy. Br Heart J 1978;40:1327–1333. 36. Sheehan FH, Bolson EL, Dodge HT, et al: Advantages and applications of the
centerline method for characterizing regional ventricular function. Circulation 1986;74:293–305. 37. Wohlgelernter D, Cleman H, Highman A, et al: Regional myocardial dysfunction during coronary angioplasty: Evaluation by two-dimensional echocardiography and 12 lead electrocardiography. J Am Coll Cardiol 1986;7:1245–1254. 38. McGillem MJ, Mancini GBJ, DeBoe SF, Buda AJ: Modification of the centerline
method for assessment of echocardiographic wall thickening and motion: A comparison with areas of risk. J Am Coll Cardiol 1988;11:861–866. 39. Ginzton, LE: Stress echocardiography and myocardial contrast echocardiography.
Cardiol Clin 1989;7:493–509. 40. Sheehan FH, Stewart DK, Dodge HT, et al: Variability in the measurement of
regional ventricular wall motion from contrast angiograms. Circulation 1983;68:550– 559.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 18
41. Gelberg HJ, Brundage BH, Glantz S, Parmley WW: Quantitative left ventricular
wall motion analysis: A comparison of area, chord and radial methods. Circulation 1979;59:991–1000. 42. Jugdutt BI, Hutchins GM, Bulkley BH, Becker LC: Myocardial infarction in the
conscious dog: Three-dimensional mapping of infarct, collateral flow and region at risk. Circulation 1979;60:1141–1150. 43. Kerber RE, Marcus ML, Ehrhardt J, et al: Correlation between
echocardiographically demonstrated segmental dyskinesis and regional myocardial perfusion. Circulation 1975;52:1097–1104. 44. Lieberman AN, Weiss JL, Jugdutt BI, et al: Two-dimensional echocardiography
and infarct size: Relationship of regional wall motion and thickening to the extent of myocardial infarction in the dog. Circulation 1981;63:739–746. 45. Wyatt HL, Meerbaum S, Heng MK, et al: Experimental evaluation of the extent of myocardial dyssynergy and infarct size by two-dimensional echocardiography. Circulation 1981; 63:607–614. 46. Pandian NG, Kyoanagi S, Skorton DJ: Relations between 2-dimensional
echocardiographic wall thickening abnormalities, myocardial infarct size and coronary risk area in normal and hypertrophied myocardium in dogs. Am J Cardiol 1983;52:1318–1325. 47. Hutchins GM, Bulkley BH, Ridolfi RL, et al: Correlation of coronary arteriograms
and left ventriculograms with postmortem studies. Circulation 1977;56:32–37. 48. Homans DC, Asinger R, Elsperger KJ, et al: Regional function and perfusion at the
lateral border of ischemic myocardium. Circulation 1985;71:1038–1047. 49. Buda AJ, Zotz RJ, Gallagher KP: Characterization of the functional border zone
around regionally ischemic myocardium using circumferential flow-function maps. J Am Coll Cardiol 1986;8:150–158. 50. Sheehan FH, Doerr R, Schmidt WG, et al: Early recovery of left ventricular
function after thrombolytic therapy for acute myocardial infarction: An important determinant of survival. J Am Coll Cardiol 1988;12:289–300. 51. Pandian NG, Skorton DJ, Collins SM, et al: Heterogeneity of left ventricular
segmental wall thickening and excursion in 2-dimensional echocardiograms of normal human subjects. Am J Cardiol 1983;51:1667–1673. 52. Assmann PE, Slager CJ, Dreysse ST, et al: Two-dimensional echocardiographic
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 18
analysis of the dynamic geometry of the left ventricle: The basis for an improved model of wall motion. J Am Soc Echocardiogr 1988;1:393–405. 53. Clayton PD, Jeppson GM, Klausner SC: Should a fixed external reference system
be used to analyze left ventricular wall motion? Circulation 1982;65:1518–1521. 54. Force T, Kemper A, Perkins L, et al: Overestimation of infarct size by quantitative
two-dimensional echocardiography: The role of tethering and of analytic procedures. Circulation 1986;73:1360–1368. 55. Parisi A, Moynihan P, Folland E, Feldman C: Quantitative detection of regional
left ventricular contraction abnormalities by two-dimensional echocardiography. II. Accuracy in coronary artery disease. Circulation 1981;63:761–767. 56. Schnittger I, Fitzgerald P, Gordon E, et al: Computerized quantitative analysis of
left ventricular wall motion by two-dimensional echocardiography. Circulation 1984;70;242–254. 57. Zoghbi WA, Charlat ML, Bolli R, et al: Quantitative assessment of left ventricular
wall motion by two-dimensional echocardiography: Validation during reversible ischemia in the conscious dog. J Am Coll Cardiol 1988;11:851–860. 58. Feneley M, Farnsworth A, Shanahan M, Cheng V: Mechanisms of the
development and resolution of paradoxical interventricular septal motion after uncomplicated cardiac surgery. Am Heart J 1987;114:106–114. 59. Feneley M, Gavaghan T: Paradoxical and pseudoparadoxical interventricular septal
motion in patients with right ventricular volume overload. Circulation 1986;74:230– 238. 60. Kittleson MD, Knowlen GG, Johnson LE: Early and late global and regional left
ventricular function after experimental transmural myocardial infarction: Relationships of regional wall motion, wall thickening, and global performance. Am Heart J 1987;114:70–78. 61. Ross J Jr, Franklin D: Analysis of regional myocardial function, dimensions, and
wall thickness in the characterization of myocardial ischemia and infarction. Circulation 1976;53:I88–I92. 62. Heikkila J, Nieminen MS: Echoventriculography in acute myocardial infarction.
IV. Infarct size and reliability by pathologic anatomic correlations. Clin Cardiol 1980;3:26–35.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 18
110
63. Feneley M, Hickie J. Validity of echocardiographic determination of left
ventricular systolic wall thickening. Circulation 1984;70:226–232. 64. Weiss RJ, Buda AJ, Pasyk S, et al: Noninvasive quantification of jeopardized
myocardial mass in dogs using 2-dimensional echocardiography and thallium-201 tomography. Am J Cardiol 1983;52:1340–1344. 65. Nieminen M, Parisi AF, O'Boyle JE, et al: Serial evaluation of myocardial
thickening and thinning in acute experimental infarction: Identification and quantification using two-dimensional echocardiography. Circulation 1982;66:174– 180. 66. Heikkila J, Tabakin BS, Hugenholtz PG: Quantification of function in normal and
infarcted regions of the left ventricle. Cardiovasc Res 1972;6:516–531. 67. Beyar R, Shapiro EP, Graves WL, et al: Quantification and validation of left
ventricular wall thickening by a three-dimensional volume element magnetic resonance imaging approach. Circulation 1990;81:297–307. 68. Erbel R, Schweizer P, Meyer J, et al: Sensitivity of cross-sectional
echocardiography in detection of impaired global and regional left ventricular function: Prospective study. Int J Cardiol 1985;7:375–389. 69. Sheehan FH, Feneley MP, DeBruijn NP, et al: Quantitative regional wall
thickening analysis by transesophageal echocardiography. J Thorac Cardiovasc Surg 1992;103:347–354. 70. Yang P, Otto C, Sheehan F: The effect of normalization in reducing variability in
regional wall thickening. J Am Soc Echocardiogr 1997;10:197–204. 71. Dumesnil J, Shoucri R, Laurenceau J, Turcot J: A mathematical model of the
dynamic geometry of the intact left ventricle and its application to clinical data. Circulation 1979;59:1024–1034. 72. Sasayama S, Franklin D, Ross J Jr, et al: Dynamic changes in left ventricular wall
thickness and their use in analyzing cardiac function in the conscious dog: A study based on a modified ultrasonic technique. Am J Cardiol 1976;38:870–879. 73. Azancot I, Masquet C, Bourthoumieux A, et al: Myocardial hypertrophy, rate of
change of free wall thickness and directional components of ventricular power in man.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 18
J Physiol (Paris) 1981;77:695–703. 74. Aurigemma GP, Silver KH, McLaughlin M, et al: Impact of chamber geometry and
gender on left ventricular systolic function in patients >60 years of age with aortic stenosis. Am J Cardiol 1994;74:794–798. 75. Dong SJ, MacGregor JH, Crawley AP, et al: Left ventricular wall thickness and regional systolic function in patients with hypertrophic cardiomyopathy: A threedimensional tagged magnetic resonance imaging study. Circulation 1994;90:1200– 1209. 76. Sandor T, Henschke C, Risser TA, et al: Quantitative analysis of left ventricular
wall motion and thickness using two-dimensional echocardiography. Int J Biomed Comput 1983; 14:431–439. 77. Ren JF, Kotler Mn, Kakki, AH, et al: Quantitation of regional left ventricular
function by two-dimensional echocardiography in normals and patients with coronary artery disease. Am Heart J 1985;110:552–560. 78. Haendchen RV, Wyatt HL, Maurer G, et al: Quantitation of regional cardiac
function by two-dimensional echocardiography. I. Patterns of contraction in the normal left ventricle. Circulation 1983;67:1234–1245. 79. Henschke CI, Risser TA, Andor T, et al: Quantitative computer-assisted analysis of
left ventricular wall thickening and motion by 2-dimensional echocardiography in acute myocardial infarction. Am J Cardiol 1983;52:960–964. 80. Miyatake K, Yamagishi M, Tanaka N, et al: New method for evaluating left ventricular wall motion by color coded tissue doppler imaging: In vitro and in vivo studies. J Am Coll Cardiol 1995;25:717–724. 81. Isaaz K, Thompson A, Ethevenot G, et al: Doppler echocardiographic
measurement of low velocity motion of the left ventricular posterior wall. Am J Cardiol 1989;64:66–75. 82. Gorcsan J III, Strum DP, Mandarino WA, et al: Quantitative assessment of
alterations in regional left ventricular contractility with color-coded tissue Doppler echocardiography: Comparison with sonomicrometry and pressure-volume relations. Circulation 1997;95:2423–2433. 83. Donovan CL, Armstrong WF, Bach DS: Quantitative Doppler tissue imaging of the
left ventricular myocardium: Validation in normal subjects. Am Heart J 1995;130:100–104.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 18
84. Uematsu M, Miyatake A, Tanaka N, et al: Myocardial velocity gradient as a new
indicator of regional left ventricular contraction: Detection by a two-dimensional tissue doppler imaging technique. J Am Coll Cardiol 1995;26:217–223. 85. Palka P, Lange A, Fleming AD, et al: Doppler tissue imaging: Myocardial wall
motion velocities in normal subjects. J Am Soc Echocardiogr 1995;8:659–668. 86. Galiuto L, Ignone G, DeMaria AN: Contraction and relaxation velocities of the
normal left ventricle using pulsed-wave tissue Doppler echocardiography. Am J Cardiol 1998;81:609–614. 87. Vinereanu D, Khokhar A, Fraser AG: Reproducibility of pulsed wave tissue
Doppler echocardiography. J Am Soc Echocardiogr 1999;12:492–499. 88. Rambaldi R, Poldermans D, Vletter WB, et al: Doppler tissue imaging in the new
era of digital echocardiography. G Ital Cardiol 1997;27:827–839. 89. Jamal F, Derumeaux G, Douillet R, et al: Analysis and quantification of
longitudinal contraction of the left ventricle in myocardial infarction. Value of Doppler myocardial tissue imaging. Arch Mal Coeur Vaiss 1999;92:315–322. 90. Rambaldi R, Poldermans D, Bax JJ, et al: Doppler tissue velocity sampling
improves diagnostic accuracy during dobutamine stress echocardiography for the assessment of viable myocardium in patients with severe left ventricular dysfunction. Eur Heart J 2000;21:1091–1098. 91. von Bibra HV, Tuchnitz A, Klein A, et al: Regional diastolic function by pulsed
Doppler myocardial mapping for the detection of left ventricular ischemia during pharmacologic stress and perfusion testing: A comparison with stress echocardiography and perfusion scintigraphy. J Amer Coll Cardiol 2000;36:444–452. 92. Yin L-X, et al: Ventricular excitation maps using tissue Doppler acceleration
imaging: Potential clinical application. J Amer Coll Cardiol 1999;33:782–787. 93. Gould KL, Lipscomb K, Hamilton GW, Kennedy JW: Relation of left ventricular
shape, function and wall stress in man. Am J Cardiol 1974;34:627–634. 94. Burton AC: The importance of the shape and size of the heart. Am Heart J
1957;54:801–810. 95. Dodge HT, Frimer M, Stewart DK: Functional evaluation of the hypertrophied
heart in man. Circ Res 1974; 34–35(suppl II), II122–II127.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 18
96. D'Cruz IA, Aboulatta H, Killam H, et al: Quantitative two-dimensional
echocardiographic assessment of left ventricular shape in ischemic heart disease. J Clin Ultrasound 1989;17:569–572. 97. Gibson DG, Brown DJ: Continuous assessment of left ventricular shape in man. Br
Heart J 1975;37:904–910. 98. Lamas GA, Vaughan DE, Parisi AF, Pfeffer MA: Effects of left ventricular shape
and captopril therapy on exercise capacity after anterior wall acute myocardial infarction. Am J Cardiol 1989;63:1167–1173. 99. Tomlinson CW: Left ventricular geometry and function in experimental heart
failure. Can J Cardiol 1987;3:305–310. 100. Bogen DK, Rabinowitz SA, Needleman A, et al: An analysis of the mechanical
disadvantage of myocardial infarction in the canine left ventricle. Circ Res 1980;47:728–741. 101. Mitchell GF, Lamas GA, Vaughan DE, Pfeffer MA: Left ventricular remodeling
in the year after first anterior myocardial infarction: A quantitative analysis of contractile segment lengths and ventricular shape. J Am Coll Cardiol 1992;19:1136– 1144. 102. Mancini GBJ, DeBoe SF, Anselmo E, LeFree MT: A comparison of traditional
wall motion assessment and quantitative shape analysis: A new method for characterizing left ventricular function in humans. Am Heart J 1987;114:1183–1191. 103. Sawada H, Fujii J, Takata H, et al: Quantitation of regional left ventricular wall motion by curvature: Two dimensional echocardiographic analysis. J Cardiogr 1986;16:789–798. 104. Jugdutt BI, Michorowski BL: Role of infarct expansion in rupture of the ventrical
septum after acute myocardial infarction: A two-dimensional echocardiographic study. Clin Cardiol 1987;10:641–652. 105. Crouse LJ, Cheirif J, Hanly DE, et al: Opacification and border delineation
improvement in patients with suboptimal endocardial border definition in routine echocardiography: Results of the phase III Albunex Multicenter trial. J Am Coll Cardiol 1993;22:1494–1500. 111
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 18
106. Feigenbaum H: Digital echocardiography in myocardial infarction. Aust NZ J
Med 1992;22:521–526. 107. Assmann PE, Slager CJ, van der Borden SG, et al: Quantitative echocardiographic
analysis of global and regional left ventricular function: A problem revisited. J Am Soc Echocardiogr 1990;3:478–487. 108. Moynihan PF, Parisi AF, Folland ED, et al: A system for quantitative evaluation
of left ventricular function with two-dimensional ultrasonography. Med Instrum 1980;14:111–116. 109. Conetta DA, Geiser EA, Skorton DJ, et al: In-vitro analysis of boundary
identification techniques used in quantification of two-dimensional echocardiograms. Am J Cardiol 1984;53:1374–1379. 110. Garcia E, Gueret P, Bennett M, et al: Real time computerization of two-
dimensional echocardiography. Am Heart J 1981;101:783–792. 111. Dodge HT, Sandler H, Ballew DW, Lord JD Jr: The use of biplane
angiocardiography for the measurement of left ventricular volume in man. Am Heart J 1960;60:762–776. 112. Helak JW, Reichek N: Quantitation of human left ventricular mass and volume by
two-dimensional echocardiography: In vitro anatomic validation. Circulation 1981;63:1398–1407. 113. Geiser EA, Wilson DC, Wang DA, et al: Autonomous epicardial and endocardial
boundary detection in echocardiographic short-axis images. J Amer Soc Echocardiogr 1998;11:338–348. 114. Vandenberg BF, Rath LS, Stuhlmuller P, et al: Estimation of left ventricular
cavity area with an on-line, semiautomated echocardiographic edge detection system. Circulation 1992;86: 159–166. 115. Lang RM, Vignon P, Weinert L, et al: Echocardiographic quantification of
regional left ventricular wall motion with color kinesis. Circulation 1996;93:1877– 1885. 116. Gillam LD, Hogan RD, Foale RA, et al: A comparison of quantitative
echocardiographic methods for delineating infarct-induced abnormal wall motion. Circulation 1984;70:113–122. 117. Himelman RB, Cassidy MM, Landzberg JS, Schiller NB: Reproducibility of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 18
quantitative two-dimensional echocardiography. Am Heart J 1988;115:425–431. 118. Brutsaert DL: Nonuniformity: A physiologic modulator of contraction and
relaxation of the normal heart. J Am Coll Cardiol 1987;9:341–348. 119. Azancot I, Vannier D, Vannier A, et al: Utilisation of a minicomputer for analysis
and database management of hemodynamic parameters for routine and research applications. In Ripley KL, Ostrow HG (eds): Computers in Cardiology. Long Beach, Calif, IEEE Computer Society, 1979, pp 441–444. 120. Huhmann W, Duangphung K: Left ventricular wall motion. A comparison of six
evaluation methods. Z Kardiol 1980;69:818–826. 121. Karsch KR, Lamm U, Blanke H, Rentrop KP: Comparison of nineteen
quantitative models for assessment of localized left ventricular wall motion abnormalities. Clin Cardiol 1980;3:123–128. 122. Papapietro SE, Smith LR, Hood WP Jr, et al: An optimal method for angiographic
definition and quantification of regional left ventricular contraction. In Ripley KL, Ostrow HG (eds): Computers in Cardiology. Long Beach, Calif, IEEE Computer Society, 1978, pp 293–296. 123. Falsetti HL, Marcus ML, Kerber RE, Skorton DJ: Quantification of myocardial
ischemia and infarction by left ventricular imaging. 1981;63:747–751. 124. Rozanski A, Diamond GA, Forrester JS, et al: Alternative referent standards for
cardiac normality. Ann Intern Med 1984;101:164–171. 125. Gerstenblith G, Grederiksen J, Yin FCP, et al: Echocardiographic assessment of a
normal adult aging population. Circulation 1977;56:273–278. 126. Tennant R, Wiggers CJ: Effect of coronary occlusion on myocardial contraction.
Am J Physiol 1935;112:351–361. 127. Gould KL, Lipscomb K, Hamilton GW: Physiologic basis for assessing critical
coronary stenosis. Am J Cardiol 1974;33: 87–94. 128. Schwarz F, Flameng W, Thiedemann K-U, et al: Effect of coronary stenosis on
myocardial function, ultrastructure and aortocoronary bypass graft hemodynamics. Am J Cardiol 1978;42:193–201. 129. Sheehan FH, Brown BG, Dodge HT, et al: Quantitative analysis of the
relationship between coronary artery stenosis and regional left ventricular wall
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 18
motion. In Sigwart U, Heintzen PH (eds): Ventricular Wall Motion. Georg Thieme Verlag, Stuttgart, 1984, pp 198–205. 130. McMahon MM, Brown BG, Cukingnan R, et al: Quantitative coronary
angiography: Quantitation of the critical stenosis in patients with unstable angina and single-vessel disease without collaterals. Circulation 1979;60:106–113. 131. Sheehan FH, Mathey DG, Schofer J, et al: Factors determining recovery of left
ventricular function following thrombolysis in acute myocardial infarction. Circulation 1985;71:1121–1128. 132. Harrison DG, Ferguson DW, Collins SM, et al: Rethrombosis after reperfusion
with streptokinase: Importance of geometry of residual lesions. Circulation 1984;69:991–999. 133. Braunwald E, Rutherford JD: Reversible ischemic left ventricular dysfunction:
Evidence for the "hibernating myocardium." J Am Coll Cardiol 1986;8:1467–1470. 134. Cohen M, Charney R, Hershman R, et al: Reversal of chronic ischemic
myocardial dysfunction after transluminal coronary angioplasty. J Am Coll Cardiol 1988;12:1193–1198. 135. Heger JJ, Weyman AE, Wann LS, et al: Cross-sectional echocardiography in
acute myocardial infarction: Detection and localization of regional left ventricular asynergy. Circulation 1979;60:531–538. 136. Nieminen M, Heikkila J: Echoventriculography in acute myocardial infarction II:
Monitoring of left ventricular performance. Br Heart J 1976;38:271–281. 137. Meltzer RS, Woythaler JN, Buda AJ, et al: Two dimensional echocardiographic
quantification of infarct size alteration by pharmacologic agents. Am J Cardiol 1979;44:257–262. 138. Visser CA, Lie KI, Kan G, et al: Detection and quantification of acute, isolated
myocardial infarction by two dimensional echocardiography. Am J Cardiol 1981;47:1020–1025. 139. Weiss JL, Bulkley BH, Hutchins GM, Mason SJ: Two-dimensional
echocardiographic recognition of myocardial injury in man: Comparison with postmortem studies. Circulation 1981;63:401–408. 140. Visser CA, Kan G, Lie KI, et al: Apex two dimensional echocardiography:
Alternative approach to quantification of acute myocardial infarction. Br Heart J 1982;47:461–467.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 18
141. O'Boyle JE, Parisi AF, Nieminen M, et al: Quantitative detection of regional left
ventricular contraction abnormalities by 2-dimensional echocardiography: Comparison of myocardial thickening and thinning and endocardial motion in a canine heart. Am J Cardiol 1983;51:1732–1738. 142. Van Reet RE, Quinones MA, Poliner LR, et al: Comparison of two-dimensional
echocardiography with gated radionuclide ventriculography in the evaluation of global and regional left ventricular function in acute myocardial infarction. J Am Coll Cardiol 1984;3:243–252. 143. Widimsky P, Gregor P, Cervenka V, Visek V: Two-dimensional
echocardiography in acute transmural and non-transmural myocardial infarction. Cor Vasa 1984;26:12–19. 144. Pandian NG, Skorton DJ, Collins SM, et al: Myocardial infarct size threshold for
two-dimensional echocardiographic detection: Sensitivity of systolic wall thickening and endocardial motion abnormalities in small versus large infarcts. Am J Cardiol 1985;55:551–555. 145. Aebischer N, Bise AC, Gabathuler J, Lerch R: Prognostic value of bidimensional
echocardiography in the acute phase of myocardial infarct. Schweiz Med Wochenschr 1985;115:1641–1646. 146. Widimsky P, Kopsa P, Cervenka V, et al: The possibility of non-invasive
identification of occluded coronary artery in acute myocardial infarction. Cor Vasa 1986;28:428–437. 147. Horowitz RS, Morganroth J: Immediate detection of early high-risk patients with
acute myocardial infarction using two-dimensional echocardiographic evaluation of left ventricular regional wall motion abnormalities. Am Heart J 1982;103:814–822. 148. Ideker RE, Behar VS, Wagner GS, et al: Evaluation of asynergy as an indicator of
myocardial fibrosis. Circulation 1978;57:715–725. 149. Reimer KA, Lowe JE, Rasmussen MM, Jennings RB: The wavefront
phenomenon of ischemic cell death. Circulation 1977;56:786–794. 150. TIMI Research Group: Immediate vs delayed catheterization and angioplasty
following thrombolytic therapy for acute myocardial infarction. J Am Med Assoc 1988;260:2849–2858. 151. Kemper AJ, O'Boyle JE, Sharma S, et al: Hydrogen peroxide contrast-enhanced
two-dimensional echocardiography: Real-time in vivo delineation of regional
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 15 di 18
myocardial perfusion. Circulation 1983;68:603–611. 112
152. Nishimura RA, Tajik AJ, Shub AC, et al: Role of two-dimensional
echocardiography in the prediction of in-hospital complications after acute myocardial infarction. J Am Coll Cardiol 1984;4:1080–1087. 153. Guyer DE, Foale RA, Gillam LD, et al: An echocardiographic technique for
quantifying and displaying the extent of regional left ventricular dyssynergy. J Am Coll Cardiol 1986; 8:830–835. 154. Wilkins GT, Southern JF, Choong CY, et al: Correlation between
echocardiographic endocardial surface mapping of abnormal wall motion and pathologic infarct size in autopsied hearts. Circulation 1988;77:978–987. 155. Mann DL, Foale RA, Gillam LD, et al: Early natural history of regional left
ventricular dysfunction after experimental myocardial infarction. Am Heart J 1988;115:538–546. 156. Kaul S, Pandian NG, Gillam LD, et al: Contrast echocardiography in acute
myocardial ischemia. III. An in vivo comparison of the extent of abnormal wall motion with the area at risk for necrosis. J Am Coll Cardiol 1986;7:383–392. 157. Maroko PR, Libby P, Ginks WR, et al: Coronary artery reperfusion. I. Early
effects on local myocardial function and the extent of myocardial necrosis. J Clin Invest 1972;51:2710–2716. 158. Mock MB, Ringqvist I, Fisher LD, et al: Survival of medically treated patients in
the Coronary Artery Surgery Study (CASS) Registry. Circulation 1982;66:562–568. 159. Schwartz RS, Ilstrup DM, Vlietstra RE, et al: Weighted ventriculographic wall
motion score for improved survival prediction in patients with coronary artery disease. Cathet Cardiovasc Diag 1989;18:79–84. 160. Nishimura RA, Reeder GS, Miller FA Jr, et al: Prognostic value of predischarge
2-dimensional echocardiogram after acute myocardial infarction. Am J Cardiol 1984;53:429–432. 161. Shah PK, Pichler M, Berman DS, et al: Noninvasive identification of a high risk subset of patients with acute inferior myocardial infarction. Am J Cardiol
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 16 di 18
1980;46:915–921. 162. Bishop HL, Gibson RS, Stamm RB, et al: Role of two-dimensional
echocardiography in the evaluation of patients with ventricular septal rupture postmyocardial infarction. Am Heart J 1981;102:965–971. 163. Jugdutt BI: Identification of patients prone to infarct expansion by the degree of
regional shape distortion on an early two-dimensional echocardiogram after myocardial infarction. Clin Cardiol 1990;13:28–40. 164. Tischler MD, Niggel J, Borowski DT, LeWinter MM: Relation between left
ventricular shape and exercise capacity in patients with left ventricular dysfunction. J Am Coll Cardiol 1993;22:751–757. 165. Nakano K, Sugawara M, Kato T, et al: Regional work of the human left ventricle
calculated by wall stress and the natural logarithm of reciprocal of wall thickness. J Am Coll Cardiol 1988;12:1442–1448. 166. Kono T, Sabbah HN, Rosman H, et al: Left ventricular shape is the primary
determinant of functional mitral regurgitation in heart failure. J Am Coll Cardiol 1992;20:1594–1598. 167. Boltwood CM, Tei C, Wong M, Shah PM: Quantitative echocardiography of the
mitral complex in dilated cardiomyopathy: The mechanism of functional mitral regurgitation. Circulation 1983;68:498–508. 168. Alam M, Rosenhamer G: Atrioventricular plane displacement and left ventricular
function. J Am Soc Echocardiogr 1992;5:427–433. 169. Weyman AE, Hogan TD Jr, Gillam LD, et al: Importance of temporal
heterogeneity in assessing the contraction abnormalities associated with acute myocardial ischemia. Circulation 1984;70:102–112. 170. Skorton DJ, Melton HE Jr, Pandian NG, et al: Detection of acute myocardial
infarction in closed-chest dogs by analysis of regional two-dimensional echocardiographic gray-level distributions. Circ Res 1983;52:36–44. 171. Armstrong WF, Mueller TM, Kinney EL, et al: Assessment of myocardial
perfusion abnormalities with contrast-enhanced two-dimensional echocardiography. Circulation 1982;66:166–173. 172. Geiser EA, Lupkiewicz SM, Christie LG, et al: A framework for three-
dimensional time-varying reconstruction of the human left ventricle: Sources of error and estimation of their magnitude. Comput Biomed Res 1980;13:225–241.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 17 di 18
173. Geiser EA, Skorton DJ, Conetta DA: Quantification of left ventricular function by two-dimensional echocardiography: Consideration of factors restricting image quality. Am Heart J 1982;103:905–910. 174. Garrison JB, Weiss JL, Maughan WL, et al: Quantifying regional wall motion and
thickening in two-dimensional echocardiography with a computer-aided contouring system. In Ostrow HG, Ripley KL (eds): Computers in Cardiology. Long Beach, Calif, IEEE Computer Society, 1977, pp 25–35. 175. Presti CF, Gentile R, Armstronf WF, et al: Improvement in regional wall motion
after percutaneous transluminal coronary angioplasty during acute myocardial infarction: Utility of two-dimensional echocardiography. Am Heart J 1988;115:1149– 1155. 176. Touchstone D, Beller GA, Nygaard TW, et al: Effects of successful intravenous
reperfusion therapy on regional myocardial function and geometry in humans: A tomographic assessment using two-dimensional echocardiography. J Am Coll Cardiol 1989;13:1506–1513. 177. Bourdillon PDV, Broderick TM, Williams ES, et al: Early recovery of regional
left ventricular function after reperfusion in acute myocardial infarction assessed by serial two-dimensional echocardiography. Am J Cardiol 1989;63:641–646. 178. Nakashima Y, Maldareli W, Oka Y, Sisto DA: Evaluation of the effects of
different cardioplegic techniques on left ventricular function during coronary artery bypass surgery using transesophageal echocardiography. Cardiovasc Surg 1993;1:587–593. 179. Slavik JR, LaMantia KR, Kopriva CJ, et al: Does nitrous oxide cause regional
wall motion abnormalities in patients with coronary artery disease? Anesth Analg 1988;67:695–700. 180. King DL, Harrison MR, King DL Jr, et al: Improved reproducibility of left atrial
and left ventricular measurements by guided three-dimensional echocardiography. J Am Coll Cardiol 1992;20:1238–1245. 181. Sheehan FH: Measurement of left ventricular function from contrast angiograms
in patients with coronary disease. In Brundage BH (ed): Comparative Cardiac Imaging—Function, Flow, Anatomy, Quantitation. Rockville, Md, Aspen Publications, 1990, pp 101–118. 182. Kloner RA: Coronary angioplasty: A treatment option for left ventricular
remodeling after myocardial infarction? J Am Coll Cardiol 1992;20:314–316.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 18 di 18
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/45.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
113
Chapter 6 - Left Ventricular Diastolic Function Clinical Utility of Doppler Echocardiography Mikel D. Smith MD
Left ventricular diastolic function is recognized as an important contributing factor in the pathophysiology of many common cardiovascular diseases. The clinical manifestations of cardiomyopathy, hypertension, and coronary artery disease are often the result of abnormalities of left ventricular filling. Diastolic dysfunction may be present prior to, or concomitant with, systolic dysfunction. Although treatments are often aimed at improving left ventricular contractile performance, they may conflict with appropriate therapy for diastolic abnormalities. Recently, attention has been increasingly directed toward the diagnosis, evaluation, and treatment of diastolic dysfunction. Although catheterization measurements of diastolic performance remain the standard, these invasive parameters have proved technically challenging and tedious to acquire. In recent years, a large body of literature has accrued describing various Doppler echocardiographic techniques for assessing diastolic function. These methods have given new insight into the flow dynamics of the left ventricle, mitral valve, and pulmonary veins and have allowed a more practical noninvasive assessment of diastolic function. Several features of Doppler flow patterns have emerged as having
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
important diagnostic and therapeutic implications. This chapter reviews the state of the art in the Doppler echocardiographic assessment of left ventricular diastolic function, relates these methods to the physiology of left ventricular filling, and describes the use of these techniques in clinical decision making.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/46.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Physiology of Diastole Definition. Traditionally, diastole has been described as the portion of the cardiac cycle that begins with aortic closure (S2 ) and ends with mitral closure (S1 ). Importantly, this definition includes the isovolumic relaxation phase. Normal diastolic function may be clinically defined as the ability of the left ventricle to accommodate an adequate filling volume to maintain cardiac output while operating at a low pressure. Phases of Diastole. For descriptive purposes, the diastolic period can be divided into four stages (Fig. 6-1) . [1] After systolic ejection is complete and left ventricular 114
Figure 6-1 Schematic of intracardiac pressures and volumes to define the four stages of diastole. The periods of isovolumic relaxation, rapid filling, slow filling (diastasis), and atrial filling are shown. See text for description. AVC, aortic valve closure; AVO, aortic valve opening; LV, left ventricle; MVC, mitral valve closure; MVO, mitral valve opening. (From Zile M: Mod Concepts Cardiovasc Dis 1989;58:67.)
pressure falls below aortic pressure, the aortic valve closes. This marks the beginning of isovolumic relaxation, which subsequently ends at mitral valve opening. During this interval, pressure continues to fall at a rapid rate, while ventricular volume remains constant. Events occurring during this phase have been attributed mainly to myocardial relaxation and have been shown to be an energy-requiring process. At this time, myofibrils return to their resting state from the contracted state. The left ventricular cavity changes in geometry, while volume remains constant.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
When left ventricular pressure falls below left atrial pressure (crossover point) the mitral valve opens, and the rapid filling phase begins. The peak rate of filling is directly related to the magnitude of the left atrial-left ventricular pressure gradient. Even though relaxation continues, the rapid increase in left ventricular volume counterbalances this effect and results in a gradual rise in pressure. Physiologically, this appears to represent a complex interaction between left ventricular suction (active relaxation),[2] and passive viscoelastic properties of the myocardium (compliance). As relaxation slows and the atrium empties, the atrioventricular pressure gradient gradually dissipates, and this phase of left ventricular filling ends. The third phase of diastole consists of passive filling during diastasis. In this period, the left atrial and ventricular pressures are nearly equal, so filling is mainly the result of pulmonary venous flow, with the left atrium essentially acting as a passive conduit. The amount of filling is directly proportional to left ventricular compliance. The final phase of diastole is atrial contraction. This active process contributes approximately 15% of left ventricular filling in normal subjects and possibly more in patients in various disease states. This phase is most affected by left ventricular stiffness and external pericardial restraint (as a resistance to left atrial ejection), atrial contractility, and left atrial-left ventricular synchrony (i.e., the PR interval). This final phase of diastole is terminated with the subsequent rise in ventricular pressure and mitral valve closure. The last three phases after mitral valve opening have also been termed auxotonic relaxation, since left ventricular volume continues to increase, although pressure changes are variable.[3]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/47.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 3
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Invasive Measures of Diastolic Function From the description just given, it should be evident that no single parameter can be derived that will adequately describe diastolic performance. Left ventricular filling is the result of a variety of complex forces, including myocardial relaxation, ventricular suction, ventricular stiffness, viscoelastic properties of the myocardium, erectile filling of the coronary arteries, atrial contraction, ventricular interdependence, and pericardial restraint. To understand the role of Doppler echocardiographic information in assessing diastolic function, it is necessary to have a working knowledge of other conventional methods. Traditionally, catheterization-based methods for studying diastolic events have focused on evaluation of the relationship between left ventricular pressure and volume. Because of the dynamic nature of diastole, measurements have been derived to describe the function of the ventricle during its isolated phases. The indices of function have centered on the evaluation of relaxation, filling, or compliance (Fig. 6-2) . As shown, these measurements are not interchangeable and, like Doppler descriptors, describe different phenomena during the sequential phases of diastole. They may also be variably influenced by changes in factors such as load or heart rate (Table 6-1) . Hemodynamic indices describing early diastolic events include peak -dP/dt, the time constant of isovolumic left ventricular pressure decay or tau (τ), the isovolumic relaxation time (IVRT), and the half-time of ventricular pressure decline (T1/2 ).[4] [5] Peak -dP/dt. Just after aortic valve closure and early during the isovolumic phase, left ventricular pressure falls exponentially. The maximal rate of this rapid pressure decline (peak -dP/dt) can be obtained with high-fidelity,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 3
micromanometer-tipped catheters in the ventricular cavity. This value is taken as the lowest value of the first derivative of left ventricular pressure (see Fig. 6-2) and typically yields values in the range of 2000 ± 400 mm Hg per second for normal subjects.[6] [7] The index becomes decreased (less negative) with impaired relaxation due to ischemia. [7] However, the peak dP/dt is dependent on sympathetic tone and absolute aortic pressure and reflects properties of left ventricular relaxation at a single point in time.[8] [9] Tau. Weiss' group and others[7] , [9] [9] have proposed the use of a time constant of relaxation (tau, τ) to describe pressure fall throughout isovolumic diastole. The measurement 115
Figure 6-2 Schematic showing the relationship of pressures, rate of pressure change (dP/dt), volumes, and Doppler transmitral and pulmonary venous flows. The portion of the cardiac cycle and index of diastolic function are shown in block letters and include tau, isovolumic relaxation time (IVRT), peak -dP/dt, peak filling rate (PFR), rapid filling fraction (RFF), and atrial filling fraction (AFF) along with the corresponding Doppler measures of transmitral and pulmonary venous flow. The derivation of these indices is described in the text, and the characteristics and limitations of these parameters are listed in Table 6-1 . Kv, modulus of chamber stiffness.
assumes a monoexponential decay in left ventricular pressure from aortic closure (taken as peak -dP/dt) to an arbitrary point 5 mm Hg above enddiastolic pressure (approximating mitral valve opening). The pressure values are converted to a logarithmic scale and fitted to a straight line (Fig. 6-3) . The negative reciprocal of the slope of this line represents the exponential decay time constant (TL) and is expressed in milliseconds. Normal values for tau range from 25 to 40 msec. Higher values represent reduced early diastolic distensibility due to relaxation at excessively slow rates. Tau may be relatively load independent[6] but does not describe events during any phases of ventricular filling. Nevertheless, the time constant of relaxation remains an accepted standard and widely used invasive descriptor of left ventricular diastolic function. Chamber Stiffness. Catheterization methods have also been derived for pressure-volume events
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 3
during filling. The assessment of diastolic mechanics in the catheterization laboratory requires highly accurate determinations of both pressure and volume. The simultaneous recording of these values allows the calculation of compliance as the rate of change in volume per rate of change in pressure, dV/dP (Fig. 6-4) . The reciprocal of this value, dP/dV (called chamber stiffness), is usually derived by obtaining pressures at different volumes, measured at end-diastole. Since this relationship is exponential for the left ventricle, the rate of change is calculated from a single point and represents the instantaneous slope of the tangent to this curve. Chamber stiffness values are preload dependent, so that an increase in volume from point A to point B will result in an increase in chamber stiffness (see Fig. 64A) . However, when dP/dV is plotted against pressure, a linear relationship exists for a given ventricle (see Fig. 6-4B) . The slope of the line describing chamber stiffness versus pressure is called the modulus of chamber stiffness, or Kv. Although Kv is relatively independent of pressure and volume, comparison between ventricles of different volume must be normalized for chamber stiffness (i.e., VdP/dV). The reciprocal dV/VdP represents specific chamber compliance. Normal values for Kv range from 0.010 to 0.025, and dV/VdP data generally fall between 0.015 and 0.045.[10] Although often difficult to acquire, these values are descriptive of events occurring in late diastole and define the passive components of ventricular filling. The values have not been validated for acute conditions, making comparisons among patients somewhat impractical.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/48.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Radionuclide Descriptors of Filling Contrast ventriculography and radionuclide angiography have been used to describe the volume changes that occur with ventricular filling.[11] When volumes are calculated and plotted over time, the resultant curve can readily define the rapid filling, diastasis, and atrial contraction phases of diastole (see Fig. 6-2) . The first derivative of this time-activity curve (dV/dt) describes the peak filling rate and time to peak filling rate. Other available measurements include the atrial filling fraction and early or rapid filling fraction. In summary, there are a number of time-honored methods for describing left ventricular diastolic function. Catheterization methods have the advantage of combining pressures with volume but are tedious, often define only a single point in time, and are load dependent. Although these elegant indices can provide significant insight regarding the physiology of ventricular diastole, their practical application to individual patients remains limited.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/49.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 25
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Doppler Echocardiographic Indices of Diastolic Function Isovolumic Relaxation Time Dynamic left ventricular relaxation begins at the time of peak systolic pressure.[12] The process continues as ventricular pressure falls below aortic pressure, ejection ceases, and the valve closes. Left ventricular pressure continues to fall even as volume remains constant during the isovolumic phase of diastole but prior to mitral valve 116
TABLE 6-1 -- Description and Limitations of Conventional Diastolic Function Indices Index Description Limitations Catheterization -dP/dt First derivative of LV pressure Sympathetic tone and decay during IVRT afterload dependent No filling data Tau (τ) Time constant of exponential No filling data decay of LV pressure during isovolumic period Kv Modulus of LV chamber Requires multiple stiffness measured at endpressures/volumes diastole Normalized for volume Radionuclide Peak filling Maximal slope of filling curve No pressures
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 25
rate Rapid filling Fraction of early, late filling fraction, atrial filling fracture Transmitral Doppler IVRT Continuous wave Doppler across MV, aortic valve; time between aortic closure, MV opening Peak E, Ei Peak A, Ai
Early filling velocities and integrals Late filling velocities and integrals
No data during IVRT
Age dependent
No filling data Preload dependent Age dependent
Limited by atrial function, heart rate, and rhythm Deceleration Deceleration time from peak E Preload dependent time to baseline velocity Pulmonary vein Doppler Peak S, Si Forward flow velocities from Age and preload atrial relaxation and MV dependent annulus motion Mitral regurgitation Peak D, Di Forward flow velocities due to Age and preload LV relaxation dependent S/D Systolic fraction; ratio (%) Age and preload from Si /Di dependent Atrial reversal
Reverse flow due to atrial contraction
Age dependent
Limited by atrial function, LV compliance A, atrial filling velocity; Ai , integral of atrial filling velocity; D,
diastolic velocity; Di , integral of diastolic velocity; E, early filling
velocity; Ei , integral of early filling velocity; IVRT, isovolumic relaxation
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 25
time; Kv, modulus of left ventricular chamber stiffness; LV, left ventricular; MV, mitral valve; S, systolic velocity; Si , integral of systolic velocity.
Figure 6-3 The derivation of the time constant of relaxation (tau) from left ventricular (LV) pressure recordings. A, Plot of LV pressure over time. The solid line represents the monoexponential decay during the isovolumic period. B, Plot of the log of these LV pressure values over time. The reciprocal of the slope of this line represents tau (TL ) expressed in milliseconds. A, slope of the line; TL , tau.
117
Figure 6-4 Derivation of the modulus of chamber stiffness from pressure and volume recordings in the left ventricle. A, Pressure/volume plot for the left ventricle is shown in a hatched line. Pressures are obtained at two separate volume states (A and B). The slope of the tangent of this line at these points represents stiffness, dP/dV. B, The stiffness values at points A and B plotted versus pressure, which gives a straight (dashed) line. The slope of this line is called chamber stiffness, Kv.
opening. M-mode echocardiography with simultaneous phonocardiography traditionally has been used to assess the length of this period between aortic closure and mitral opening.[13] With the aortic closure sound (phono) recorded on a separate channel from but with the same time sweep as mitral leaflet opening (M-mode echo), the aortic closure-mitral opening time interval (representing IVRT) can be readily measured. The IVRT has been described for normal subjects and for subjects in various disease states, including hypertrophic cardiomyopathy and ischemic heart disease.[14] [15] Generally, as relaxation becomes impaired, the IVRT is prolonged, with normal values approximating 65 ± 20 msec.[16] More recently, the phonocardiographic method has been replaced by a continuous wave Doppler echocardiographic method. In this technique, the continuous wave beam is directed from the apical five-chamber view across the region between the aortic outflow tract and the mitral inflow tract (Fig. 6-5) . The Doppler echocardiographic spectrum in this position includes aortic valve flow with valve closure and the onset of mitral inflow, so that
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 25
the aortic closure-mitral opening interval can be determined. Comparisons of Doppler IVRT with catheterization measurements of this time period have shown reasonable correlations.[17] Notably, nuclear scintigraphy conventionally includes the IVRT in the early filling phase, since the volume/count technique is unable to distinguish isovolumic changes.[11] [18] [19]
The IVRT has been demonstrated to be shortened in restrictive cardiomyopathy, probably because of high left atrial pressures resulting in early mitral opening.[20] Although the IVRT describes a limited portion of early diastole, abnormalities of this index have been described as a noninvasive predictor of ventricular diastolic dysfunction in doxorubicininduced cardiomyopathy.[21] However, measurement of the IVRT as the sole predictor of diastolic function is limited, since no information on ventricular filling is provided (see Table 6-1) . Transmitral Flow The use of pulsed Doppler echocardiography to describe events of left ventricular filling is based on the assumption that transmitral blood flow velocities are representative of volumetric flow.[22] According to the law of conservation of mass, true volumetric transmitral flow is equal to the velocity of flow times the area of the orifice (F = A × V). Thus, the dynamic nature of the mitral orifice during diastole plays a role in producing the flow profile. Although the mitral cross-sectional area remains Figure 6-5 Technique for measurement of isovolumic relaxation time by continuous wave Doppler with the beam directed between the aortic outflow tract and mitral inflow. The interval between aortic valve closure (valve click) and onset of mitral flow can be measured in milliseconds (arrow).
118
Figure 6-6 Normal pulsed wave Doppler recording taken from mitral valve tips showing peak E (early) and A (late) diastolic flows as well as a low-velocity flow during diastasis (L wave). The integrated area under the early peak (Ei ) and late peaks (Ai ) can be measured, as can the deceleration time (DT).
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 25
relatively constant in size at the annulus level, the diastolic area of flow constantly changes at the leaflet tips.[23] The Doppler velocity profile, therefore, does not represent a direct recording of volumetric flow but is proportional to the atrioventricular pressure gradient, according to the modified Bernoulli equation: P1 − P2 = 4(V2 ), one of the main
determinants of transvalvular blood flow.[24] [25] True volumetric flow rates can be derived when combined with valve area measurements, although a significant benefit of this step in assessing diastolic function has not been well established.
The typical pulsed wave Doppler transmitral spectral pattern is shown in Figure 6-6 . The two phases of forward flow in early diastole and late diastole can be readily identified by their triangular shape and are separated by a brief period of diastasis. The early phase, or E wave, represents flow during the rapid filling phase, while the second peak, or A wave, represents transmitral flow occurring as a result of atrial contraction. The E and A waves are two well-defined peaks within the spectrum and usually display a linear upslope and downslope that can be measured as acceleration and deceleration, respectively, in centimeters per second.[2] Other conventional measurements include the peak E and A velocities, as well as the integrated areas within each phase, Ei and Ai . At slower heart rates, the E and A waves are separated by low, flat velocities during diastasis. These velocities are more readily recorded using low wall filter settings and sweep speeds of 50 or 100 mm per second. Occasionally, a separate distinct and positive inflow wave is seen immediately after the E wave; this wave has been designated the L wave (see Fig. 3-6) . It is thought to represent pulmonary venous flow passing through the left atrium, which acts as a conduit during this period.[26] Studies performed to compare transmitral velocities with ventricular cineangiography have found a significant correlation for both early and late phases. [17] [27] , [28] Studies by Friedman et al[11] and Spirito et al [19] demonstrated similar findings for Doppler versus radionuclide techniques. However, filling time intervals between Doppler and these methods have not correlated well, in part because of the inclusion of IVRT by nuclear methods but not by Doppler echocardiography.[11] Normative data from Doppler transmitral velocities have been reported mainly as control data for studies of various disease states.[29] [30] [31] [32] [33] [33] A normal peak E wave velocity is in the range of 70 to 100 cm per second,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 25
with a peak A wave of 45 to 70 cm per second, resulting in an E/A ratio of 1.0 to 1.5. The normal deceleration time (DT) for the E wave is 160 to 220 msec. Table 6-2 gives a summary of normal values from various echocardiography laboratories as taken from the literature. The recording methods and the populations sampled vary considerably among centers. Therefore, normative data should be established for each laboratory using standard examination and measurement techniques so that individual subjects can be evaluated against control subjects. Abnormal Transmitral Flow Patterns
Although the ranges for normal values are wide and Doppler parameters are affected by a variety of hemodynamic and physiologic factors, patients with proven diastolic dysfunction have been shown to demonstrate characteristic abnormalities in the spectral flow profile. Rarely is a single finding diagnostic of a specific disease process, but constellations of abnormalities tend to be present for a given pathophysiologic condition.[34] Thus, three distinct clinical patterns of abnormal transmitral flow have been described. [34] [35] [36]
The first pattern consists of a prolonged IVRT and deceleration time with a reduced peak E and an increased peak A wave velocity (Fig. 6-7) . These findings have been associated with normal early diastolic filling pressures and are attributed to impaired left ventricular relaxation.[35] [37] The delay in relaxation directly lengthens the IVRT and produces a smaller atrioventricular gradient in early diastole. The effect is a reduced E wave velocity with a more Figure 6-7 Impaired relaxation pattern of Doppler transmitral flow. A reduced E wave velocity, prolonged deceleration time (DT), and predominant flow during atrial contraction (A) are characteristic of this pattern.
119
TABLE 6-2 -- Normal Values Reported for Transmitral Flow b
Study
Age Sample Subjects Range Volume Peak E Ei Peak A Ai (N) (yr) Location (cm/sec) (cm) (cm/sec) (cm) E/A
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 25
Takenaka, et al[14]
16 19–60 Tips
60 ± 9
— 38 ± 8
Gardin, et al[56]
52 21–78 Midleaflet
54 ± 12
— 47 ± 11
Graettinger et al[31]
47 12–14 Tips
Maron et al
35
73 ± 12 6.5 39 ± 7 ± 1.4 69 ± 12 — 27 ± 7
29
[96]
Bryg et al [42]
Gardin et al
Highest recorded
33 30–49 Highest 62 ± 14 recorded
— 33 ± 7
18
— 46 ± 13
50
Highest 59 ± 14 recorded
10 24–29 Annulus 108 ± 10
— 58 ± 15
12 30–49 Annulus 103 ± 16
— 71 ± 17
10 50–68 Annulus 91 ± 16
— 80 ± 15
8 21–30 Tips
66 ± 11
— 41 ± 7
18 61–70 Tips
45 ± 10
— 55 ± 11
[32]
Douglas et al[30]
17 29–60 Annulus 62 ± 9
— 40 ± 8
— 1.52 ± 0.25 — 1.06 ± 0.35 2.2 1.37 ± ± 0.5 0.2 — 2.7 ± 0.7 — 2.0 ± 0.6 — 1.2 ± 0.4 — 1.98 ± 0.53 — 1.52 ± 0.36 — 1.07 ± 0.41 — 1.6 ± 0.31 — 0.82 ± 0.34 — 1.61 ± 0.39
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Wind et al
Pagina 8 di 25
Appleton et al[35]
40 22–60 Tips
Hatle et al
20 27–63 Tips
1.5 ± 0.32 1.1 ± 0.3 0.89 ± 0.4 0.87 ± 0.17 86 ± 16 13 ± 56 ± 13 5.5 1.6 2.9 ± ± 1.1 0.5 84 ± 18 — 61 ± 14 — —
40 25–65 Tips
86 ± 16
[115]
Drinkovic et al[28]
Pearson et al[89]
24 42–76 Annulus 68 ± 12 8.6 ± 1.8 62 20–66 Tips 64 ± 10 8.9 ±2
48 ± 11 3.6 ± 1.0 59 ± 8 5.3 ± 1.1 Annulus 47 ± 13 6.1 52 ± 10 4.3 ± ± 1.5 0.9 18 65–84 Annulus 58 ± 15 — 69 ± 17 —
[107]
— 1.6 ± 0.5 Kitzman et 10 21–32 Tips 82 ± 12 11 ± 43 ± 10 4.1 1.85 [29] al 2.6 ± ± 1.2 0.25 10 62–73 Tips 56 ± 13 7.9 59 ± 14 5.5 0.92 ± ± ± 2.2 1.2 0.4 25 25–45 Tips 74 ± 8 — 38 ± 3.2 2.5 1.96 Cacciapuoti [33] ± ± et al 0.7 0.2 25 46–65 Tips 73 ± 7 — 38 ± 3 2.4 1.82 ± ± 0.6 0.25 25 66–85 Tips 70 ± 5 — 62 ± 3.1 2.6 1.28 ± ± 0.5 0.24 A, atrial filling velocity; Ai , integral of actual filling velocity; E, early fil Klein et al
— 56 ± 13
[36]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 25
filling velocity; IVRT, isovolumic relaxation time. gradual downslope (or prolonged deceleration time). The increased peak A wave velocity and Ai are likely the result of diminished early diastolic flow
with a higher left atrial residual volume at the time of atrial contraction.[35]
A second transmitral flow pattern has been termed restrictive (Fig. 6-8) . The characteristics of this pattern are a short (or normal) IVRT and reduced deceleration time, along with increased E wave and diminished A wave Figure 6-8 Restrictive pattern of Doppler transmitral flow. The high early velocity (E), short deceleration time (DT), and diminished atrial velocity (A) are typical of this pattern.
velocities.[20] [36] Thus, filling is predominantly shifted to the rapid filling phase in early diastole and is thought to be due to a high cross-over pressure at the time of mitral valve opening in the presence of a relatively nondistensible left ventricle. The result is a high early velocity of transmitral flow but with rapid equilibration of the atrioventricular pressures and an abrupt cessation of flow (short deceleration time). Late diastole is characterized by diminished atrial transport caused by high left ventricular pressures, poor atrial function, or both.[20] [36] A third pattern has been termed normalized or pseudonormal.[35] This pattern has characteristics of normal transmitral velocities but results from counterbalancing influences of both abnormal relaxation and restrictive forces. This pattern represents an intermediate pattern between the two ends of the pathologic spectrum and may be viewed as a transition from one pattern to another.[34] An example of a pseudonormal pattern is shown in Figure 6-9 . The pseudonormal flow pattern shows nearly equal E and A wave velocities, with a deceleration time that is either normal or shortened. The fact that flow patterns can be seen to change over time within individual patients has caused concern that transmitral Doppler tracings alone may not be used to 120
Figure 6-9 Pseudonormal pattern of Doppler transmitral flow. Nearly equal E and A velocities, with a slightly prolonged deceleration time
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 25
(DT), are shown.
identify diastolic dysfunction.[38] [39] Indeed, it is currently recognized that patients with a pattern of impaired relaxation may convert to "normal" (pseudonormal) as a result of increased mitral regurgitation, hypervolemia, or increased ventricular stiffness resulting from progression of the underlying disease. These physiologic changes can all potentially produce an increased E wave and more rapid deceleration slope. Similarly, the restrictive pattern may be affected by lowering preload.[40] [41] The ability of Doppler flow patterns to mutate as a result of changes in load compromises the use of these recordings from a single examination to assess diastolic function. Thus, serial studies, along with available clinical or direct hemodynamic information, may be beneficial in sorting out findings in individual patients. In addition, studies of Doppler recordings of pulmonary vein flow have contributed to knowledge in this area. Physiologic Factors Affecting Transmitral Flow
A number of physiologic variables have been shown to influence the pattern of flow across the mitral valve during diastole; these include age, heart rate, heart rhythm, loading conditions, systolic function, atrial function, and phases of respiration. The complex interplay of these parameters results in the final spectral Doppler echocardiographic signal. It is therefore important to consider each of these factors to interpret the clinical relevance of the Doppler echocardiographic findings. Age.
Age has been found to be an important determinant of the transmitral flow profile.[32] [42] In studies of normal populations, the peak E wave and integrated E wave (Ei ) velocities have been shown to decrease with advancing age from 20 to 75 years. The peak A and Ai velocities increase
with age, resulting in a decreased E/A ratio.[43] Furthermore, the IVRT and deceleration time have been demonstrated to be progressively longer with age. Thus, Doppler examination of normal, young patients may resemble the restrictive pattern, whereas patients with advanced age often show findings compatible with impaired relaxation. It has been proposed that these changes are due to the development of left ventricular hypertrophy, since wall thickness and mass are known to increase over time in the normal population.[44] An increase in hypertrophy
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 25
and myocardial stiffness could lead to delayed relaxation and result in prolonged IVRT, decreased E wave, and longer deceleration time. This development of a "physiologic state of hypertrophy" remains hypothetical, since Doppler echocardiographic characteristics were not dependent on blood pressure or left ventricular mass in these studies.[29] Heart Rate.
Changes in heart rate affect the resulting transmitral flow pattern by several mechanisms. As heart rate increases and the diastolic interval is shortened, the A wave begins to encroach on the preceding E wave. Studies of patients with dual-chamber pacemakers have shown a decreased E wave peak velocity and Ei , with concomitant increases in A waves with heart rates up to 90 beats per minute. [45] The increase in atrial contribution may be due to a reflex increase in myocardial contractility (the Bowditch phenomenon); a rise in left atrial pressure; or, more simply, the result of higher atrial volume at the onset of atrial systole due to elimination of diastasis.
Similarly, in normal volunteers with atrial pacing via a transesophageal electrode, the peak A wave was seen to increase by a mean value of 8 cm per second for each increment of 10 beats per minute in heart rate.[46] Most studies have shown that at rates greater than 100 beats per minute, the E and A waves become fused, making conventional measurements of peak velocities, velocity integrals, and acceleration or deceleration unobtainable in most cases (Fig. 6-10) . Heart Rhythm.
Changes in atrioventricular synchrony due to alterations in the PR interval, atrial fibrillation, or ectopic rhythms can cause dramatic changes in Doppler transmitral flow. A prolongation of the PR interval usually results in a reduced E wave component, possibly due to more complete atrial emptying and a reduced diastolic time interval, especially during the rapid filling period. Atrial ectopic rhythms and heart block may provide a variety of E and A wave profiles depending on the timing of atrioventricular dyssynchrony (Fig. 6-11) . Atrial fibrillation results in an absence of organized A wave velocities, with variable E waves, depending on the length of the preceding RR interval. Loading Conditions.
Loading conditions have a substantial impact on the Doppler transmitral flow pattern. The most important variable appears to be the left ventricular
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 25
preload, which can have a profound effect on E wave velocities. A study by Choong et al[40] first demonstrated that the administration of nitroglycerin reduced the peak Figure 6-10 Fusion of the E and A waves due to increased heart rate. The peak early (arrow) and late velocities remain distinguishable.
121
Figure 6-11 Doppler transmitral flow in a patient with atrial fibrillation. The tracing shows variability in peak E wave velocities depending on RR interval. No A wave velocities are present.
E, Ei , and deceleration rates of the rapid filling phase without significant
changes in A wave parameters. Most importantly, these changes were noted to resemble the pattern of impaired relaxation, even though there was no hemodynamic evidence for diastolic dysfunction. The mechanism for these changes is felt to be related to a decreased left atrium—left ventricle pressure gradient at the time of mitral valve opening ("cross-over pressure"), which results in lower E wave velocities. [47] Other studies using a tilt table or lower body negative pressure have substantiated these findings.[48] Conversely, increasing preload by volume expansion in a canine model has been shown to result in an increased peak E wave velocity, with a lesser effect on the A wave. [49] Of all hemodynamic parameters evaluated, left atrial pressure was the most significant determinant of peak E wave values. Systolic Function.
Left ventricular systolic function also affects the transmitral flow rate during the rapid filling phase. Studies in dogs[50] and humans[51] have shown that left ventricular end-systolic volume is indirectly correlated with peak E wave velocity. Thus, in the presence of systolic dysfunction or increased afterload, the early diastolic velocities can be expected to be reduced, with deceleration time prolonged. These important studies make it clear that one must take volume status and loading conditions into account before classifying patients into categories of diastolic dysfunction. Obviously, patients evaluated in an
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 25
echocardiographic laboratory may be subject to extremes of load and volume due either to the underlying disease process or to treatment with vasoactive drugs. Careful consideration of these circumstances must be given to individual patients during analysis of the Doppler data. Atrial Function.
The size and functional status of the left atrium itself may contribute to changes in the Doppler transmitral flow profile. For example, it has been noted that the reduced atrial contractility (or "atrial stunning") that occurs after cardioversion of patients with atrial fibrillation or flutter results in a reduced peak A-wave velocity.[52] Thus, despite restoration of sinus rhythm, the atrial transport function (and A wave component) of diastole may remain impaired for weeks after cardioversion.[52] , [53] Theoretically, any acute process affecting atrial function (e.g., inflammation, scarring, or infarction) could produce similar abnormalities in transmitral flow. Respiration.
The physiologic intrathoracic pressure changes that occur during normal breathing produce minor changes in transmitral flow. As a result of negative pressures—and, consequently, enhanced peripheral venous return—developed during inspiration, right heart and transtricuspid flows predominate.[54] [55] Concurrently, the transmitral velocity spectrum yields reduced peak E wave velocities in the range of 5% to 10%.[55] Since little or no change is seen in the corresponding A wave, the E/A ratio may fall slightly under that seen in normal circumstances. These changes are compatible with known physiologic reduction of left ventricular preload during inspiration. However, in situations of acute right heart strain or pericardial tamponade, the effect of respiration on transmitral flow has been shown to be much more dramatic. To minimize respiratory changes, most laboratories record the transmitral spectral Doppler echocardiogram with the patient in held, shallow endexpiration. Technical Considerations of Transmitral Flow Measurements Two-Dimensional Imaging Plane.
Doppler recordings of transmitral flow must be performed in a standardized fashion for consistency. Since the Doppler equation includes a term for angle of incidence (cos theta), the technique for recording transmitral flow
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 25
velocities is optimally performed from the apical window (four-chamber, two-chamber, or long-axis views). Most laboratories use the four-chamber view because of its orthogonal relationship to the major diameter of the mitral annulus. Pulsed Wave versus Continuous Wave Doppler.
Because of its superior temporal and range resolution, pulsed wave Doppler echocardiography is the preferred technique for recording transmitral flow. Although the continuous wave method may ensure that the highest velocities are recorded, these signals may arise from other locations along the interrogating beam path (i.e., from aortic insufficiency) rather than via diastolic transmitral flow. In addition, the pulsed wave signal provides a "cleaner" outer border that readily lends itself to tracing peak velocities and slopes. However, the continuous wave Doppler technique is required for obtaining the IVRT, as previously described. Sample Site.
Studies in the literature differ according to optimal location of the pulsed wave sample volume. Some investigators have recommended placing the sample volume near the center of the mitral annulus, just on the ventricular side, using two-dimensional imaging for positioning. This scheme has the advantage of being more reproducible among patient studies and providing a better evaluation of the atrial component.[56] Recordings made between the mitral leaflet tips yield higher velocities of flow and a better assessment of the rapid filling phase.[57] [58] Since no clear consensus currently exists, each laboratory must establish a protocol for recording and analysis, as the spectral profiles often differ at these locations (Fig. 6-12) . As shown in Table 6-2 , normal values are sample site dependent, and published studies must be read carefully if the methods are to be reproduced.
122
Figure 6-12 Pulsed wave Doppler transmitral flow recordings from the two most commonly used sample sites. Top, Spectral pattern recorded from mitral valve leaflet tips shows nearly equal E and A wave components. Bottom, Recording from mitral valve annulus level demonstrating a smaller E wave and predominant A wave. Modal Velocity.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 15 di 25
Flow through the normal mitral orifice with normal cardiac output remains essentially laminar and has a blunt profile.[59] Thus, the border of the pulsed wave velocity spectrum generally exhibits very little spectral dispersion, since at any given instant the red cell targets within the region of interest are moving at nearly the same speed and direction. However, the border does show a finite width. The darkest portion of this band represents the modal velocity and has been suggested as the best location for tracing or measuring the spectrum, as it should be less susceptible to changes in gain. [56]
E and A Waves.
At slower heart rates, the early (E) and late (A) contributions to left ventricular filling can be readily identified, as well as the lower velocities occurring during diastasis (if wall filters are kept low). However, at heart rates above 100 beats per minute, the individual E and A waves often become fused,[46] making measurements of Ei and Ai difficult. At higher
heart rates (around 130 beats per minute), peak velocities may not be readily discriminated and appear as a single large wave (see Fig. 6-10) . Various approaches have been taken to this problem. For example, the E and A waves can be measured by extrapolating the descending and ascending slopes, respectively, through the merged portion of velocity spectrum. Another approach involves dropping a perpendicular line from the point of convergence. Our experience suggests that integrated timevelocity values may be less reliable in this setting and that perhaps only peak velocity values should be used, since these usually remain distinctly visible. The E wave deceleration time can usually be obtained by extrapolating the visible portions of the downslope to the baseline. If Ei and
Ai are to be measured, a convention should be adopted for the laboratory. It should be noted that use of these different methods may account for differences in time-velocity integrals and time intervals between separate examinations and centers. Diastasis.
The velocities recorded between the E and A waves represent the ventricular filling that occurs during diastasis. Normally these velocities are low and represent a very small contribution to overall volume of flow. Indeed, if wall filters are increased to eliminate noise around the baseline, the velocity spectrum during the period may be completely eliminated. Since this portion of the Doppler spectrum may be helpful in understanding
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 16 di 25
pulmonary vein flows, the wall filters should be adjusted as low as possible to eliminate noise and yet preserve the outer border of the spectrum during this time period. Deceleration Slope versus Deceleration Time.
Measurements of the descending limb of the transmitral E wave have been reported in terms of both deceleration slope (cm per second squared)[14] [60] and time (msec).[35] [36] The slope is defined by the rate of decline from the peak velocity, whereas deceleration time describes the time interval between peak velocity and the point of intercept of the decay slope (or extrapolated slope) with the baseline. Although these parameters have both been used to describe relaxation events in early diastole, they are not equivalent. The deceleration slope is influenced by and directly related to peak E velocity, whereas deceleration time has the advantage of being more independent of the E velocity.[34] Pulmonary Vein Flow Normal Patterns
Doppler echocardiographic recordings of flow within the pulmonary venous system have been obtained using both transthoracic and transesophageal windows. [61] These spectral patterns have yielded important insight into the physiology of left ventricular filling and diastolic function. The pattern of flow is largely determined by transmitral flow and left atrial function. A typical example of pulsed wave Doppler recording of pulmonary vein velocities is shown in Figure 6-13 . The pattern consists of two forward waves and one reverse (below the baseline) wave. One forward wave occurs during systole (S) and coincides with left atrial relaxation immediately after atrial contraction. The systolic wave occasionally demonstrates two separate components at slow heart rates; these may be distinguished by a notch in the upslope (see Fig. 6-13B) . The early component (SE ) is thought to result from atrial relaxation, and the late systolic wave (SL ) has been described as originating from movement of the mitral annulus toward the apex.[61] [62]
The other forward wave occurs during diastole (D) and coincides with the early transmitral flow and ventricular filling but is delayed by approximately 50 msec.[26] In this
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 17 di 25
123
Figure 6-13 Normal Doppler pulmonary vein flow tracings using transthoracic (A) and transesophageal (B) techniques. A, Nearly equal systolic (S) and diastolic (D) waves and a small reverse flow at enddiastole (Ar). B, Transesophageal recording demonstrates laminar flow with well-defined early (SE ) and late (SL ) systolic waves.
context, the diastolic flow can be viewed as produced by ventricular relaxation, resulting in forward pulmonary vein flow, with the left atrium acting as a conduit after mitral valve opening. With short RR intervals, the systolic and diastolic waves may merge, resulting in a single forward-flow wave. Thus, depending on heart rate and rhythm, the pulmonary vein velocities above the baseline may be recorded as monophasic, biphasic, or triphasic.[26] Reverse flow can often be recorded as a small, brief velocity signal below the baseline during atrial contraction (just after the P wave). This wave has been variously designated the pulmonary vein A (PVa) or atrial reversal (Ar) wave and represents retrograde pulmonary vein flow (see Fig. 6-13) . It is usually larger when the atrial afterload is high from left ventricular hypertrophy or restrictive/constrictive processes.[34] [63] Some workers have termed the systolic and diastolic forward waves as J and K waves [26] [64] or X and Y waves, respectively.[65] Although labeling of the pulmonary vein velocity has not yet been standardized as for transmitral flow, most recent investigators have used the S and D designations. This format has the advantage of being readily associated with timing within the cardiac cycle. However, the J and K terminology is more easily associated with the L wave of transmitral flow during diastasis and thus is preferred in some laboratories. Other authors have named these as X and Y waves to correspond to the x and y descent of the pulmonary capillary wedge pressure tracings. In this scheme, the atrial reversal velocity is called the Z wave.[66] Measurements
As with the transmitral flow, the conventional assessment of pulmonary vein velocity waves has included the measurement of peak velocities, as well as the time velocity integral for S (Si ) and D (Di ). The ratio of the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 18 di 25
systolic to diastolic components has also been described by peak S/peak D or expressed as the systolic fraction (percent) by the following equation[63] [66]
The peak Ar velocity, velocity time integral, and duration (Adur , in milliseconds) have also been defined.[41] [63] [66]
Fewer studies of normative data are available for pulmonary vein flow than for transmitral Doppler data. Table 6-3 lists the mean (±SD) values reported from a number of important series in the literature for reference. However, as indicated, some of these investigations were performed in patients undergoing catheterization or elective operations and thus may not reflect values obtained during a routine echocardiographic examination. In general, the S wave is predominant in normal patients, with peak velocities ranging from approximately 40 to 60 (±15) cm per second and time velocity integrals of 15 ± 5 cm. The SE component is usually smaller than SL, with peak velocities of 30 to 40 (±10) cm per second. The diastolic wave has been measured in the range of 35 to 45 (±15) cm per second with a velocity integral of around 7.5 to 9.5 (±4) cm. The ratio of peak S to peak D has been described in normal subjects as 1.3 to 1.5 (±0.3), with a systolic fraction of 60 to 68 (±10%). The peak A wave is normally the smallest of the velocity components at -22 to -32 (±10) cm per second, with integrated values of 2 ± 1 cm. The Ar duration has been found to be helpful in the clinical interpretation of pulmonary vein flow and is approximately 137 ± 31 msec. Abnormal Patterns of Pulmonary Vein Flow
The alterations in transmitral waveforms seen in various cardiac disease states and loading conditions and with aging have also been described for pulmonary vein velocities.[34] , [41] Since pulmonary vein tracings provide additional information about atrial filling and function, these patterns have been used in conjunction with transmitral flows to better define abnormalities of ventricular filling. In patients with impaired left ventricular relaxation, the pulmonary vein
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 19 di 25
flow during early diastole (D) becomes smaller, corresponding to decreased E wave velocities at the transmitral site, both being related to a slower rate of ventricular relaxation. As a result, pulmonary vein flow is shifted toward the systolic phase (S) and results in a 124
TABLE 6-3 -- Normal Values Reported for Pulmonary Vein Flow by Pu
Study Keren et al[62] Keren et al[26] Nishimura et al[41] * Kuecherer et al[66] * Castello et al[61]
Age Patients Range Peak S Si Peak D Di Fra (N) (yr) Technique (cm/sec) (cm) (cm/sec) (cm) (% 13 1–83 TTE 44 ± 10 — 53 ± 15 — — 12
26–49 TTE
48 ± 8
— 49 ± 11
—
—
19
45–80 TEE
41 ± 13
— 33 ± 14
—
—
60
35–78 TEE
19
20–65 TEE
41 ± 13 9.2 32 ± 15 ±4 52 ± 15 12 ± 44 ± 14 4.4
12
TTE
Kuecherer et al[65] Arakawa et al[71]
12
33–60 TTE
44
17–70 TEE
Rossvoll and Hatle
28
15–75 TTE
5.2 66 ± ±3 — 7.8 ± 4.4 50 ± 14 11 ± 41 ± 6 2.5 — 1.5 ± 3.1 63 ± 18 — 46 ± 12 — 68 ± —
12.8 — ± 3.3 56 ± 12 — 40 ± 13
— 68 ±
— 65 ±
[63] †
Brunazzi et al[67] †
96
40
TTE
48 ± 13 11.7 57 ± 10 12.7 47 ± ±4 ±2
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 20 di 25
41–50
50 ± 11 12.5 46 ± 11 11.4 54 ± ±4 ±2 51–60 55 ± 12 13.3 40 ± 9 10.5 56 ± ±3 ±4 61 60 ± 10 15.1 36 ± 14 9.7 61 ± ±4 ±4 Ar, atrial reversal velocity; Adur, atrial reversal duration; Di , integral of d
systolic velocity; Si , integral of systolic velocity; D, diastolic velocity; TEE echocardiography; TTE, transthoracic echocardiography.
* During coronary artery bypass grafting. † Undergoing diagnostic catheterization with normal pulmonary wedge pressure.
higher peak S, Si , and systolic fraction (Fig. 6-14A and B) . The effect on
the Ar wave is variable, depending on left ventricular distensibility at atrial contraction.[34] [63] If left ventricular compliance remains low, the Ar remains normal or small; however, if compliance is diminished, the Ar wave can become dramatically increased, reflecting Figure 6-14 Transmitral (A) and pulmonary vein flow (B) in a hypertensive patient with impaired relaxation. The transmitral pattern reveals typical peak A greater than peak E and prolonged deceleration time. Pulmonary vein flow shows a predominant systolic (S) wave and a small or absent Ar wave. C and D, Corresponding tracings from a patient with similar history. The transmitral pattern again shows a prolonged deceleration time and prominent A wave, while the pulmonary vein flow demonstrates a large Ar wave and prominent S wave.
more reflux into the pulmonary veins due to a resistance to forward emptying during atrial contraction (see Fig. 6-14C and D) . The pseudonormal pattern is thought to represent a transition between impaired relaxation and restrictive phases and is associated with a normal transmitral flow. Patients 125
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 21 di 25
Figure 6-15 Patient with a pseudonormal transmitral flow (A) and corresponding pulmonary vein recording (B). As atrial compliance has become reduced, the pulmonary vein flow demonstrates smaller forward velocities during systole and predominant diastolic flow (D).
in this category often have had progressive increases in left atrial volume and pressure due to decreasing left ventricular compliance over time. Because atrial compliance often becomes gradually reduced in this setting, the pulmonary venous flow during systole (S) is reduced owing to decreased atrial relaxation. Thus, the diastolic (D) wave may become predominant, with Si /Di less than 1 and systolic fraction less than 50%. A characteristic feature to this pattern is also a larger Ar wave, reflecting reduced ventricular compliance (Fig. 6-15) .
The features of pulmonary vein velocity waveforms in patients with restrictive physiology are a small S wave and a large D with an abrupt cessation of flow. The Ar wave size and duration are variable depending on the state of left atrial function. If left atrial contractility is preserved, the pulmonary vein A may be very large and prolonged. However, if left atrial failure has occurred due to chronic dilation, the Ar may become diminutive (Fig. 6-16) . A summary of the combined characteristics of transmitral and pulmonary vein flow changes commonly seen in various disease states is shown in Table 6-4 .[34] Estimation of Left Atrial Pressure
A relationship between pulmonary venous flow variables and mean left atrial or left ventricular diastolic pressures Figure 6-16 Transmitral recording in a patient with restrictive transmitral flow pattern (A) and corresponding pulmonary vein flow (B) from an apical transthoracic approach. Both demonstrate evidence of high velocities during early diastole (arrows). The pulmonary vein recording shows virtually no forward systolic flow and a small or absent Ar wave.
has been described.[63] [66] [67] [68] Kuecherer et al[66] compared pulmonary vein flow variables as well as mitral inflow with mean left atrial pressure (LAP) in 47 consecutive patients undergoing cardiovascular surgery and transesophageal echocardiography. The pulmonary vein systolic fraction correlated best with LAP (r = -.88; SEE = 3.5 mm Hg). The relationship between the two parameters was described by the following equation:
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 22 di 25
LAP = 35 − 0.39 × (systolic fraction) The authors believed that the shift from predominant systolic flow to diastolic flow seen with rising left atrial pressure was most likely due to decreased left atrial compliance.[66] Retrospective evaluation of the data also suggested that a systolic fraction less than 55% was 91% sensitive and 87% specific for predicting a mean left atrial pressure of 15 mm Hg or greater. A similar study using transthoracic pulmonary venous flow recordings was reported by Brunazzi et al[67] in 116 consecutive patients undergoing elective catheterization that included measurements of pulmonary capillary wedge pressures (PCWP). The systolic fraction was again noted to correlate best, with r = -.88 and SEE = 3.1 mm Hg. A success rate of 83% was reported in recording 126
TABLE 6-4 -- Characteristic Doppler Findings in Various Stages of Diastolic Dysfunction
E/A DT, msec IVRT, msec S/D AR, cm/sec Vp ,
Normal (young) >1 <220
Normal (older) ≥1 <220
Delayed Pseudonormal Restrictive Relaxation Filling Filling <1 1–2 >2 >220 150–200 <150
<100
<100
>100
60–100
<60
<1 <35
≥1 <35
≥1 <35
<1 ≥35
<1 ≥25
>55
>45
<45
<45
<45
>8
<8
<8
<8
cm/sec Em , >10
cm/sec AR, pulmonary venous peak atrial contraction reversed velocity; DT, early left ventricular filling deceleration time; E/A, early-to-atrial left
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 23 di 25
ventricular filling ratio; Em , peak early diastolic myocardial velocity;
IVRT, isovolumic relaxation time; S/D, systolic-to-diastolic pulmonary venous flow rate; Vp , color M-mode flow propagation velocity.
Modified from Garcia MJ, Thomas JD, Klein AL: J Am Coll Cardiol 1998;32:872. pulmonary vein flow from the transthoracic window, and the authors suggested that a systolic fraction of less than 36% percent predicted a mean PCWP of 18 or greater, with a 90% sensitivity and 85% specificity. Rossvoll and Hatle[63] have demonstrated a strong relationship between systolic fraction and the pre-A wave left ventricular end-diastolic pressure (LVEDP). A systolic fraction less than 40% was predictive of LVEDP greater than 18 mm Hg (r = -.70). These investigators also found that the pulmonary A wave duration (Adur ) was frequently prolonged, whereas the transmitral A wave was significantly shortened in patients with increased LVEDP. The difference ([PV − Adur ] − [M − Adur ]) in milliseconds
correlated best with LVEDP (r = -.68). A longer duration of the pulmonary vein A wave than transmitral A wave predicted LVEDP greater than 15 mm Hg with a sensitivity of 85% and specificity of 79%. This study was also recorded using the transthoracic approach in 45 patients undergoing diagnostic catheterization. Factors Affecting Pulmonary Vein Flow
As with transmitral recordings, a number of physiologic factors may affect the pulmonary vein Doppler echocardiographic velocity profile. Age.
Studies of normal subjects with a wide age range have demonstrated that the diastolic components are diminished and the systolic velocities are increased with advancing age.[69] [70] [71] A trend toward a larger atrial flow reversal wave has also been noted, perhaps reflecting abnormalities of left ventricular diastolic performance as part of the normal aging process. Loading Conditions.
The volume of pulmonary venous flow occurring during systole is dependent on preload—that is, with preserved myocardial contractility and increasing preload (i.e., volume loading), the atrial preload will also
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 24 di 25
increase, resulting in increased pulmonary venous systolic flow. This increase in S and S/D has been observed in human studies in the operating room[65] and in canine experiments.[72] A direct correlation between both systolic and diastolic forward flows and cardiac output has also been found. [41]
The effect of afterload was studied by Nishimura et al.[41] Patients given phenylephrine in the operating room exhibited variable responses in pulmonary vein flow patterns. Those with a dramatic rise in PCWP (>50%) showed an increase in diastolic pulmonary vein velocities, and a middiastolic flow wave (L) became apparent. Mitral Regurgitation.
Changes in transmitral and pulmonary vein velocity profiles have been found to be useful clinical markers for the estimation of severity of mitral insufficiency. Castello et al[73] found a significantly lower peak S/D velocity ratio (0.4 ± 1.3) in patients with moderate to severe regurgitation compared with patients with less regurgitation (1.4 ± 0.5, P < .0001). This trend toward "systolic blunting" was more remarkable as regurgitation worsened. In patients with severe mitral regurgitation, the systolic flow was reversed (retrograde) into the pulmonary veins. The presence of reversed systolic flow was identified as a sensitive (90%) and specific (100%) marker for severe regurgitation in the 75 patients evaluated.[73] Similar results were reported by Klein et al.[74] An equally high sensitivity and specificity for reversed systolic flow was noted, and the pattern subsequently returned to normal after operative repair in 22 patients. Thus, significant mitral regurgitation may alter the phasic appearance of pulmonary venous flow, with a progressive increase in the diastolic (D) wave component for increasing grades of insufficiency. Technical Considerations in Pulmonary Vein Flow Recordings Transesophageal versus Transthoracic Methods.
The pulmonary vein flow spectrum is generally of superior quality when recorded from the transesophageal window. The transesophageal window has been described as especially helpful in recording reversed flow during atrial contraction (Ar) and in separating the two components of forward systolic flow (SE and SL) (see Fig. 6-13) .[73] Indeed, the transthoracic method may be limited in these areas, yielding Ar recordings of acceptable quality in the minority of patients studied.[69] [73]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 25 di 25
When the transthoracic four-chamber view is used, the right upper (medial) pulmonary vein is recommended for sampling. Spectral data from this site correlate well with velocities recorded from the same vein using the transesophageal technique.[73] The use of color flow or newly available echocardiographic contrast agents may help in identifying the location of the pulmonary vein orifice and in improving Doppler signal intensity from transthoracic studies.[73] Although 127
the esophageal window normally allows imaging of all four pulmonary veins, the upper veins are preferred for sampling because they provide a more parallel flow angle for Doppler interrogation.[70] The advantages of the transesophageal study must be weighed against those of patient discomfort to determine the need for this procedure in each clinical instance. Sample Position.
The ideal position for sampling pulmonary vein velocities and analyzing waveforms is 0.5 to 1 cm from the pulmonary vein orifice into the left atrium.[73] Sampling at greater depths results in spectral broadening, decreased diastolic flow velocities, and loss of phasic characteristics of systolic flow.[64] Pulmonary Vein Size.
One potential factor affecting reproducibility of pulmonary vein inflow velocities is variation of the vein orifice size during the cardiac cycle. Studies of vein dimensions and flow in both dogs and humans have not demonstrated this to be a substantial factor under physiologic conditions.[75] However, in comparisons between mitral and pulmonary vein flow velocities, this factor must certainly be considered.[41]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/50.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 14
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Clinical Applications of Doppler Techniques for Assessing Diastolic Function Transmitral and Pulmonary Vein Recordings: A Combined Approach From the preceding discussion, it should be clear that no single noninvasive or catheterization-derived parameter can be used to describe the complex nature of diastolic function. As with systolic measures of performance, there are general descriptors (e.g., ejection fraction) and more specific measurements (e.g., Vmax , dP/dt, and mean velocity of circumferential
fiber shortening [Vcf ]) that define the process of contractility in greater
detail. Each measurement must be evaluated in the context of the clinical situation so that modifiers such as age, loading conditions, and volume status can be included.
Since the 1980s, diastolic dysfunction has become increasingly recognized as an important part of many clinical syndromes.[76] [77] [78] [79] Consequently, Doppler echocardiography has been recognized as a readily available tool for evaluating left ventricular filling and has given the clinician a method for better understanding these events. However, it must be recognized that the diagnosis of diastolic abnormalities is not routine and requires significant effort and knowledge, even for the experienced echocardiographer. In specific disease states, Doppler variables have provided a conceptual framework for understanding pathophysiology without necessitating cardiac catheterization. Recordings of transmitral and pulmonary vein flows, along with isovolumic relaxation time, should be evaluated in context with other two-dimensional echocardiographic information to best apply these techniques (see Table 6-4) . For example, in the assessment of left ventricular filling, the thickness, cavity size, and systolic function, as well as left atrial size, should be assessed. In other settings, the Doppler
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 14
data may provide more subtle clues that are helpful in distinguishing restrictive from constrictive processes. Thus, although the Doppler information represents a significant advance in the field, its use for detecting abnormal hemodynamics may still be considered part of the "art of medicine." [80] More recent studies also suggest that these noninvasive indices may give insight regarding the prognosis of various heart diseases. [81] Therefore, the following section reflects an attempt to give illustrative case examples of the use of Doppler in various cardiac problems. The cases include a discussion of relevant literature regarding the use of Doppler in these areas; further details can be found in subsequent chapters as noted. Case Examples and Literature Review Hypertensive Heart Disease (Pressure Load Left Ventricular Hypertrophy)
A 74-year-old woman with a history of hypertension presented to the clinic with complaints of dyspnea on exertion. Specifically, for the past 6 months she has had difficulty climbing stairs, carrying laundry, and vacuuming the house. Physical examination revealed a blood pressure of 170/110 with a heart rate of 90 beats per minute. There was no jugular venous distention or evidence of pulmonary congestion. Trace pedal edema was present. The left ventricular impulse was sustained, the carotid pulses were normal, and a grade 2/6 systolic ejection murmur was heard along the left sternal border. A 12-lead electrocardiogram revealed high voltage and secondary ST-T wave changes compatible with left ventricular hypertrophy. Twodimensional echocardiography with Doppler was performed to evaluate left ventricular function. Interpretation.
The Doppler transmitral flow recording from this patient is shown in Figure 6-17 and exhibits several features characteristic of patients with hypertension and left ventricular hypertrophy. The spectral profile shows a reduced E wave, prolonged deceleration time, and predominant A wave. The peak E/A ratio is less than 1.0, and the deceleration time was measured to be 200 msec. The IVRT was also found to be prolonged at 150 msec (see Fig. 6-17B) . These features are consistent with the pattern of impaired relaxation. The reduced velocities of early filling reflect the loss of ability of the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 14
hypertrophied ventricle to relax quickly and develop a negative pressure gradient ("suction") after mitral opening. The prolonged deceleration time shows that the process of relaxation continues well into diastole, while the increased peak A velocities and Ai show that the atrial volume remains high in late diastole and that atrial contractility is preserved in this case. Although a similar pattern may also be seen in healthy elderly patients, the magnitude of prolongation of deceleration time and IVRT are helpful in distinguishing this as abnormal relaxation. A prolonged IVRT has been reported to be a sensitive sign of this condition, independent of heart rate.[82]
128
Figure 6-17 A, Transmitral pulsed wave recording of a patient with hypertensive heart disease showing delayed deceleration time at 200 ms (arrow) and A greater than E. B, The isovolumic relaxation time (IVRT) (dashed lines) was prolonged at 150 msec. C, Pulmonary vein recordings in the same patient showing absent D wave and prominent Ar velocities suggesting reduced left ventricular (LV) compliance.
The Doppler pulmonary vein flow (see Fig. 6-17C) demonstrates a reduced D component (corresponding to a smaller transmitral E wave) and more prominent S wave (due to larger atrial stroke volume). However, if left ventricular compliance is reduced, a prominent Ar wave may also be seen. [83]
Literature Review.
Several studies of adult patients with hypertensive left ventricular hypertrophy have found this constellation of abnormalities to be present and statistically to be significantly different from findings in control subjects (see Chapter 32) .[84] [85] [86] [87] The pattern of impaired relaxation has also been reported in patients with concentric left ventricular hypertrophy due to aortic stenosis,[88] hypertensive hypertrophic cardiomyopathy of the elderly,[89] and hypertrophy due to obesity heart syndrome.[90] [91] Further evidence that the pathophysiology is related to hypertrophy is available from longitudinal studies in which regression is associated with reversion of this pattern to normal. Progressive improvement in E/A velocities have been demonstrated over 3 to 6 months in patients treated with angiotensin-converting enzyme inhibitors[92] [93] and in patients undergoing aortic valvuloplasty.[94] These effects may be due to
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 14
the direct reduction of afterload or the inhibition of connective tissue protein and collagen production by these drugs.[92] The classic example of impaired relaxation shown (see Fig. 6-17) is not always seen in patients with hypertensive left ventricular hypertrophy. Indeed, patients with high left atrial pressures may have a normal or "pseudonormalized" transmitral flow pattern.[35] [95] Elevated filling pressures result in a higher cross-over pressure gradient in early diastole, resulting in a larger E wave, while left ventricular end-diastolic pressures become elevated to result in smaller atrial contribution. For example, the pseudonormal pattern has also been reported in patients with aortic stenosis and systolic dysfunction[88] and those with chronic hypertension with eccentric hypertrophy.[85] The presence of significant mitral regurgitation may also elevate early filling velocities and result in a normal pattern. However, these exceptions should be apparent from clinical or echocardiographic information. Some authors have suggested that the transmitral flow profile can be used to help choose antihypertensive therapy [95] that is, when delayed relaxation is present, patients are more likely to benefit from a slower heart rate (e.g., beta blockers). Conversely, patients with elevation of diastolic filling pressures may be more likely to respond to diuretics or vasodilator therapy. Clearly, more clinical trials are necessary to assess drug effects on diastolic function and Doppler velocity patterns. Hypertrophic Cardiomyopathy
The diastolic Doppler transmitral velocity profile in patients with hypertrophic cardiomyopathy is variable (see Chapter 27) . Most patients have some evidence of diastolic dysfunction when compared with control subjects. Studies by Maron et al[96] and Lewis et al[97] showed that more than 80% of patients with hypertrophic cardiomyopathy, including those without symptoms or obstruction, had at least one abnormal index of transmitral flow. Typically, the abnormalities were similar to those described for hypertensive hypertrophy: a reduced E velocity, larger A wave component, and prolonged IVRT and deceleration time. These data are concordant with results of nuclear studies of left ventricular filling in patients with hypertrophic cardiomyopathy. Bonow et al[98] described reduced filling during the rapid filling phase, with more filling occurring during atrial systole. However, other investigators have shown that patients with this disorder may present with normal (or pseudonormal) flow profiles.[14] [33] Subgroup analyses in these studies suggest that this pattern may result from mitral regurgitation, a common associated finding.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 14
Dilated Cardiomyopathy
A 52-year-old man with a long history of an "enlarged heart," diagnosed as idiopathic dilated cardiomyopathy, 129
has been treated with digoxin and diuretics. He presented to the clinic with a history of medical noncompliance and excessive salt and water intake for 3 weeks. Echocardiograms in the past revealed four-chamber enlargement, a dilated hypocontractile left ventricle with thin walls, and an estimated ejection fraction of 30%. Physical examination showed elevated neck veins, bibasilar rales, a pulsatile enlarged liver, and dependent edema to the knees. A grade 2/6 pansystolic murmur was heard at the apex. A two-dimensional echocardiographic and Doppler study was performed to evaluate left ventricular function and rule out pericardial effusion (Fig. 618) and compared with a study performed 1 year earlier. Interpretation.
The tracings in Figure 6-18 demonstrate a number of important findings that can be helpful in the diagnosis and management of this patient. The earlier recording (see Fig. 6-18A) shows a transmitral pattern similar to that shown in Figure 6-7 . The delayed deceleration time and predominant A wave suggest impaired relaxation. However, the spectral Doppler scan now has changed to reflect a restrictive pattern (see Fig. 6-18B) . As the disease process has continued, ventricular compliance has decreased, despite a lack of any evident change in systolic performance. A rising left atrial pressure (higher preload) has resulted in a predominant E component, while the A wave has diminished due to deteriorating contractility and a more noncompliant left ventricle (higher atrial afterload). Most importantly, the availability of serial tracings greatly aids in this assessment of worsening diastolic dysfunction. Literature Review.
Several studies have evaluated left ventricular filling patterns in patients with congestive heart failure due to dilated cardiomyopathy (see Chapter 26) .[81] [99] [100] [101] [102] The combined data suggest that patients with this disorder may present with any of the patterns within the spectrum of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 14
diastolic abnormalities. Lavine and Arends [100] found that patients with dilated cardiomyopathy and normal left ventricular filling pressures had a prolonged IVRT and reduced E/A ratio, while those with pulmonary capillary pressures greater than 15 mm Hg demonstrated an increased peak E and E/A (2.1 ± 0.4). The two patient groups had similar ages, left ventricular dimensions, and degrees of systolic dysfunction. Mitral regurgitation appeared to be one factor accounting for increased E velocities. Similarly, Takenaka et al[103] found that dilated cardiomyopathy patients without mitral regurgitation typically had a pattern of abnormal relaxation, Figure 6-18 Transmitral flow recordings in a patient with dilated cardiomyopathy. The earlier recording (A) shows a slightly delayed deceleration time and A greater than E, suggesting an impaired relaxation pattern. Transmitral flow recording 1 year later (B) shows markedly an increased E wave and a near-absent A wave typical of the restrictive pattern. Conversion to this pattern suggests a higher preload and has been associated with a poorer prognosis.
whereas patients with mitral regurgitation had a "normalized" pattern. Subjects in the mitral regurgitation group differed from normal subjects in having a shorter deceleration time. Vanoverschelde et al[101] also found the pattern of left ventricular filling to be closely related to both left atrial pressure and the presence of significant mitral regurgitation. Because the majority of patients with dilated cardiomyopathy are studied while on medications, drug effects must also be considered. A study by Makhoul et al[104] demonstrated a direct relationship between PCWP changes induced by intravenous isosorbide dinitrate and the transmitral E/A ratio. The E/A ratio was initially high (restrictive pattern) and was reduced by more than 50% after nitrates in nearly all patients with class IV congestive heart failure. Perhaps the most important clinical information obtainable from Doppler tracings in patients with dilated cardiomyopathy and heart failure relates to functional status and prognosis. Studies by Vanoverschelde et al[101] and Xie et al[105] have demonstrated a clear relationship between transmitral flow pattern and New York Heart Association functional class. Patients with increased peak E velocities or shortened deceleration, or both, had poorer treadmill performance compared with those who had a pattern of impaired relaxation. These clinical data support the idea that the restrictive pattern represents increased preload and abnormal left ventricular compliance.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 14
Studies by Xie et al[81] and Werner et al[99] have shown the restrictive filling pattern to predict a higher mortality rate in patients with systolic dysfunction. Both series found that patients with a deceleration time of 140 msec or less and an E/A ratio 2.0 or greater had a 2-year survival rate of approximately 50%, compared with heart failure patients with reduced ejection fractions but without this pattern who had a survival rate greater than 90%. Although some authors have correlated an increased peak E wave and higher mortality rate with the degree of mitral regurgitation, [101] two 1994 studies[81] [99] showed no significant difference in this parameter. Thus, the pattern of short IVRT, predominant early diastolic filling (by transmitral peak E wave and pulmonary vein D waves), and a prominent Ar wave and dilated left atrium may all reflect a stage of severely decreased left ventricular compliance and high filling pressures.[34] Findings of this nature may have direct clinical applications, such as encouraging more aggressive medical treatment or consideration of earlier evaluation for heart transplantation.
130
In summary, patients with systolic dysfunction, ventricular dilation, and clinical evidence of heart failure may be heterogeneous in their Doppler transmitral or pulmonary venous flow patterns. However, interpretation of these tracings can be extremely helpful if the clinical setting is considered. [102] [106]
Constrictive Pericarditis versus Restrictive Cardiomyopathy
A 38-year-old man presented with severe dyspnea on exertion, worsening over the past year. An earlier evaluation had revealed normal pulmonary function and "no evidence of cardiac disease," based on normal systolic function. Physical examination revealed elevated jugular venous pressure with Kussmaul's sign and pulsus paradoxus of 15 mm Hg; blood pressure was 90/60. The liver was palpably enlarged, with evidence of ascites and 3+ peripheral edema. There were no audible murmurs or gallops. A Doppler echocardiographic examination was obtained to evaluate left ventricular function and to rule out a constrictive or restrictive process. Interpretation.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 14
The spectral Doppler tracings from this patient are shown in Figure 6-19 . The findings are typical for the "restrictive" transmitral flow pattern: a short IVRT, a high-velocity peak E wave (>100 cm per second) with abrupt cessation of flow and, therefore, extremely short deceleration time (120 msec). The A wave component is nearly absent, with a peak velocity of less than 35 cm per second, and resultant peak E/A of 2.2. The Ei /Ai ratio is also increased at 2.4. The dramatic shift of flow to early diastole along with abrupt cessation of the E wave is compatible with the "dip and plateau" pattern seen in right and left ventricular pressure tracings in patients with constrictive pericarditis. The beat-to-beat variation in E wave size is noteworthy and corresponds to changes during respiration frequently seen with constrictive
Figure 6-19 Spectral Doppler transmitral flow in a patient with constrictive pericarditis. The tracing shows high peak E velocity greater than 100 cm/sec and small A component barely visualized because of high heart rate. The beat-to-beat variation in E wave size shows a greater than 50% change during inspiration (arrows). This finding may be helpful in distinguishing constrictive pericarditis from restrictive cardiomyopathy.
physiology, but less often with restrictive cardiomyopathy. Literature Review.
Appleton, Hatle, and Popp have published several studies describing the typical Doppler echocardiographic features of patients with restrictive cardiomyopathy. [20] [107] These series included patients with systemic infiltrative disorders (e.g., amyloidosis and Fabry's disease) and postcardiac transplant patients.[107] Comparison of these patients with normal subjects and with a group with coronary artery disease led to the initial description of the patterns of transmitral flow: impaired relaxation, "normalized," and restrictive.[35] Comparison of flow velocity patterns with invasive hemodynamic data showed correlations between transmitral E wave and left ventricular filling pressure (r = .59), and between IVRT and the rapid filling wave (r = -.72). Klein et al[36] demonstrated similar Doppler findings in a large group of 53 patients with biopsy-proven cardiac amyloidosis. This study found the restrictive pattern to be most associated with advanced stages of the disease. Pulmonary vein flows were also recorded by transthoracic echocardiography in 29 patients and showed that those with advanced disease had markedly decreased peak systolic (S) filling and increased diastolic (D) filling compared with normal subjects.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 14
Atrial systolic function was believed to remain intact (despite left atrial enlargement), since the Ar wave was prominent in 10 patients. A follow-up study of 63 consecutive patients with biopsy-proven cardiac amyloidosis from the same center has shown a high 1-year mortality rate in patients with the restrictive pattern (51%) compared with those who had a deceleration time greater than 150 msec (8%; P < .001). The combination of shortened deceleration time and increased peak E/peak A ratio greater than 2.1 was the most predictive of a high-risk group, whereas the E/A ratio alone exhibited the single best correlation with survival.[108] Fewer clinical data are available from patients with constrictive pericarditis. A study by Hatle et al[107] compared seven patients with constrictive pericarditis, 12 with restrictive cardiomyopathy, and 20 normal subjects. Both constrictive and restrictive groups demonstrated a shorter transmitral deceleration time during held breathing at end-expiration, compared with control subjects. However, during normal inspiration, the patients with constriction showed marked increases in IVRT (50%) and decreases in peak E wave velocity (mean, -33%; all patients, greater than 25%), and these changes were small in the restrictive and control groups (see Fig. 6-19) . Indeed, no patient in the restrictive group had a greater than 15% change in either variable. The transtricuspid flow velocity changes of an increased peak E wave and a peak A wave with shortened deceleration time were also much larger in the constrictive pericarditis patients. The respiratory variation was not seen in five patients who underwent repeat studies after pericardial stripping. The authors theorized that the dramatic changes in transmitral and transtricuspid flow seen during inspiration likely were due to displacement of the interventricular septum and ventricular interdependence in patients with constriction who have a fixed total cardiac volume. Conversely, patients 131
with restrictive cardiomyopathy have a marked reduction in left ventricular compliance that remains relatively constant regardless of the respiratory phase.[107] Thus, patients with abnormalities in ventricular filling due to restrictive muscle disease or pericardial constriction may be readily identified by the "restrictive" Doppler transmitral filling pattern. These data suggest that careful study of diastolic transmitral and transtricuspid velocity during the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 14
phases of respiration may also be used to separate these groups. Although these results are promising, larger series are needed to confirm these findings. Pericardial Effusion and Cardiac Tamponade
Abnormalities in left ventricular filling have been described in patients with cardiac tamponade. A preliminary report from Pandian et al[109] first described alterations in flow velocity across all four cardiac valves; these alterations coincided with the phases of respiration. The primary study was carried out in a canine model but also included three patients who had documented tamponade physiology and underwent pericardiocentesis. The authors noted an increase in transtricuspid flow velocities and concomitant decrease in transmitral peak E and A waves (-42%) during inspiration. Appleton et al[110] studied seven patients with tamponade compared with 14 patients who had effusion due to malignancy, cardiac surgery, myocardial infarction, chronic renal failure, or cardiac transplantation. The patients with tamponade and severe hemodynamic alterations had a significant change in transmitral filling indices when the first Doppler beat of expiration was compared with the first beat of inspiration: peak E (−43 ± 9%), peak A (−25 ± 12%), IVRT (85 ± 14 msec), Ei (−52 ± 10%), and Ai (−28 ± 22%). Similar decreases were noted in aortic velocities, whereas transtricuspid and transpulmonic flows increased during inspiration. The variation was eliminated after pericardial drainage. Half of the group of patients without tamponade also showed respiratory variations compared with control subjects, but not of the magnitude seen in patients with tamponade. The authors concluded that the Doppler flow abnormalities seen with effusion are extremely sensitive to changes in pericardial pressure and should be viewed as a continuum.
In an animal model described by Gonzales et al,[111] significant respiratory variation in Doppler parameters was noted to occur at low intrapericardial pressures and preceded the echographic findings traditionally associated with clinical tamponade (i.e., right atrial inversion[112] and right ventricular diastolic collapse[113] ). It was concluded that the Doppler findings are sensitive and persist throughout all stages of tamponade but are not predictive of pericardial pressures or the severity of hemodynamic compromise. Picard et al[114] demonstrated similar findings using aortic and pulmonic flow velocities in animals. Their report did not include mitral or tricuspid Doppler data but acknowledged that the E and A waves tended to
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 14
merge in tamponade because of associated tachycardia, and that the transtricuspid Doppler interrogation was often difficult because of compression of the right heart chambers. These limitations may also prove substantial in patients with severe clinical cardiac tamponade. Myocardial Ischemia
Several studies have demonstrated that acute coronary occlusion results in diastolic dysfunction (see Chapter 12) . Most studies have used Doppler indices recorded before and during angioplasty in patients with angina[15] [115] [116] as the clinical model for evaluating the effects of ischemia on diastolic function. Wind et al[115] reported an increased proportion of left ventricular filling during late diastole and a decreased E/A ratio in 34 patients with normal global systolic function who underwent Doppler echocardiographic examination 1 day before and 1 day after coronary angioplasty for angina. These findings were thought to be consistent with impaired relaxation, as previously reported from radionuclide scans in coronary angioplasty patients.[117] The authors provided indirect evidence that the abnormal diastolic indices were due to a prolongation of IVRT, although this was not directly measured. Labovitz et al[116] investigated 32 patients during coronary angioplasty and found that evidence of diastolic left ventricular dysfunction was the earliest change during coronary occlusion with the balloon, preceding electrocardiographic changes, chest pain, or systolic wall motion abnormalities. Impaired relaxation was the pattern most often exhibited and occurred within 15 seconds of balloon inflation but returned to baseline by 15 seconds after deflation. Masuyama et al[118] also found a reduction in peak E-wave velocities and E/A ratio in serial Doppler echocardiographic studies of patients undergoing percutaneous transluminal coronary angioplasty to be a strong predictor of significant coronary restenosis. The most complete comparison of hemodynamic and Doppler indices of diastolic function in patients with coronary disease has been performed by Stoddard et al.[15] Their study evaluated the relationship of chamber stiffness and relaxation (tau) to the traditional transmitral indices in 35 patients undergoing diagnostic catheterization for chest pain. Subjects without coronary artery disease and with normal relaxation were found to have a direct correlation between increasing chamber stiffness and enhanced early filling velocities. Conversely, the group with coronary
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 14
disease showed a significant indirect correlation between impaired relaxation and decreased peak E velocity. Although their findings differ from those of previous studies in that a variety of patterns of transmitral flow were found, they are consistent with early observations by other investigators.[119] The authors concluded that chamber stiffness has a greater influence than relaxation on the pattern of diastolic filling in patients without coronary disease. In contrast, abnormal relaxation appears to be the predominant factor influencing the Doppler pattern in patients with coronary disease and an abnormal tau value. El-Said et al[120] studied the effects of ischemia on left ventricular filling using Doppler transmitral flow recordings 132
during dobutamine stress echocardiography. Their data showed marked decreases in peak E velocities (-22%) and time to peak E acceleration (28%) in ischemic subjects, whereas 10 control subjects had an increase in both values (+33% and +75%, respectively; P < .0001). There was no overlap in the percentage change from baseline to peak dobutamine stress values between normal subjects and patients who had documented singlevessel coronary disease. The authors also found diastolic abnormalities to be more sensitive than induction of wall motion abnormalities for detecting coronary stenoses. Thus, the transmitral Doppler pattern of impaired relaxation appears to be the type most often seen in association with acute (or induced) myocardial ischemic syndromes. Fewer data exist for patients with chronic coronary artery disease or previous myocardial infarction. Fujii et al[121] showed a reduced E/A ratio and prolonged deceleration time to be common in patients with a history of infarction, regardless of location. Other studies comparing inferior with anterior infarct patients have suggested that transtricuspid Doppler echocardiographic recordings may be more sensitive in demonstrating abnormal filling and high right ventricular end-diastolic pressures.[122] One study also suggests a significant relationship among infarct size, degree of systolic dysfunction, and restrictive transmitral flow patterns.[123] This pattern is seen more often in coronary artery disease patients with a worse functional class and poorer prognosis.[81] [105] However, larger studies specifically designed to assess the clinical applicability of Doppler filling patterns in this population are currently not available.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 14
Another active area of investigation is the use of Doppler echocardiographic techniques to assess changes in left ventricular relaxation produced by commonly used cardioactive drugs. Myreng and Myhre[124] first reported enhanced relaxation and a shift in left ventricular filling toward early diastole in 20 patients given oral verapamil. The patients studied had documented coronary artery disease and showed baseline transmitral filling patterns that did not differ from those of control subjects. After verapamil administration, an increased peak E velocity and E/A ratio and shortening of IVRT were seen. The authors have reported a similar "normalization" of transmitral flow in coronary disease patients after beta blocker treatment.[125] However, the effects of calcium and beta blockade on diastolic function remain controversial.[126] Caramelli et al[127] concluded that the shift in transmitral flow to early diastole can be attributed to effects on heart rate and an increase in pulmonary wedge pressure in a study of 32 patients with anterior wall infarction who were given intravenous atenolol. Nishimura et al[128] have also shown an increase in peak filling rate and a concomitant rise in left ventricular end-diastolic pressure after intravenous verapamil, with no consistent change in tau in 20 patients with coronary artery disease and preserved left ventricular function. Thus, although the use of Doppler echocardiographic methods for assessing pharmacologic effects on diastolic function remains promising, peak filling rates alone should not be used as a marker for improved relaxation. Pulmonary Hypertension
The role of the pericardium and right ventricular function in left heart filling have been recognized from elegant animal studies by Ross,[129] Sonnenblick,[130] and Glantz and coworkers.[131] [132] Patients with primary pulmonary hypertension have also been found to have abnormal left ventricular filling by Doppler echocardiography. [133] Essentially, these patients have been described as having a redistribution of transmitral flow to late diastole, with low E/A ratio (often <0.5), and prolongation of the IVRT. Louie et al[133] have shown this finding to be related to distortion of the left ventricular geometry caused by flattening of the interventricular septum. A subsequent study from the same center showed that patients with right ventricular volume overload (from severe tricuspid insufficiency) had a normal IVRT and reduced atrial component.[134] These effects were related to differences in timing of leftward septal displacement in patients with an intact pericardium. These and other studies[135] point out the importance of diastolic ventricular interaction as a determinant of filling, which may have
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 14
profound effects on relaxation and early diastole (see Chapter 33) . Post-Cardiac Transplantation
The noninvasive evaluation of the transplanted heart has become an integral part of the long-term follow-up of post-cardiac transplantation patients (see Chapter 30) . An increase in left ventricular mass, decreased volume, and evidence of reduced systolic function have all been described in patients who have acute or chronic rejection.[136] [137] [138] Doppler abnormalities of diastolic function have also been described.[137] [139] [140] [141] [142] In a large series of patients, Valantine et al[141] evaluated 64 patients undergoing hemodynamic and Doppler echocardiographic studies as part of the routine follow-up 1 to 13 years (mean, 5 years) after cardiac transplantation. Ten patients were found to have strikingly abnormal (restrictive) transmitral flow patterns. This group had a higher incidence of rejection as the only identifiable clinical difference. Restrictive filling also was associated with impaired systolic performance. Preliminary data comparing Doppler parameter recordings with endomyocardial biopsy findings have shown a relationship between transtricuspid (right ventricular IVRT) and transmitral (left ventricular IVRT) flow patterns and degree of rejection as assessed microscopically.[141] [143] Although preliminary, these data encourage the notion that, in the future, noninvasive examination of transplant patients may help to define which chronic transplant patients have a low likelihood of rejection and thus avoid the need for repeated biopsies.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/51.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 6
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Newer Doppler Echocardiographic Approaches to Diastolic Function Two-Dimensional Left Ventricular Volume Methods Echocardiographic methods have been described to assess the time course of diastolic changes in left ventricular 133
Figure 6-20 (color plate.) Recording of left ventricular (LV) volume curves (A) using acoustic quantitation. This method allows a real-time assessment of area or volumes and rate of change (B) within a region of interest. The technique provides curves similar to those of radionuclide angiography for assessing the contributions of early and late filling.
volume and dimension.[144] [145] M-mode methods are limited by the need for geometric assumptions to calculate volume and inaccuracies introduced by regional wall motion differences. Traditional two-dimensional techniques require off-line manual tracing of imprecise borders from multiple stillframe images. The frame rate produced at usual scanning depths (around 30 per second) is also slow relative to the instantaneous changes that occur during the isovolumic time period. As a result of these problems, alternative methods have been developed. Research in this area has led to the development of computer-assisted automated border detection algorithms.[146] [147] By differentiating between ultrasound backscatter from myocardium and low-energy reflectances from blood within the left ventricular cavity, these systems can track the motion of the endocardial edge throughout the cardiac cycle. Commercially available programs currently include a real-time assessment of area, volumes, and rate of change within a region of interest (Fig. 6-20) . The accuracy of this method compares well with manual edge tracing and has
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 6
been validated in studies using radionuclide and cineangiographic standards. [148] [149] The main advantage of these methods of quantitation is the on-line availability of data. Comparisons between Doppler and acoustic quantitation in diastolic measurements of the rapid filling and atrial filling phases have shown significant correlations. [150] Therefore, this method has potential uses in evaluating left ventricular filling. However, the technique is gain dependent and requires significant operator experience to acquire reproducible data, especially in patients with characteristics that lead to less than ideal image quality.[151] Noninvasive Measurement of Tau The rate of left ventricular pressure decline has remained a reference standard for the assessment of the relaxation phase of diastole, but its measurement is invasive and requires the use of high-fidelity catheters. A new method has been developed to noninvasively measure tau using continuous wave Doppler spectral recordings of mitral regurgitation.[152] [153] The method involves tracing the deceleration phase of the mitral regurgitant spectral signal and applying the Bernoulli equation to obtain the instantaneous pressure gradient between the left ventricle and the left atrium (Fig. 6-21) . The derivation of tau from this velocity curve has been validated in both animal[152] and human[153] studies using simultaneous catheterization data for corroboration. Although the technique necessitates offline computer analysis of tracings and is not applicable in patients without a complete mitral regurgitant envelope, the results are promising, showing good correlations with results of invasive methods. Additional clinical studies are needed to determine the feasibility of this technique in clinical practice. Color M-Mode Doppler Echocardiography Several investigators have described a new method for relating ventricular inflow velocities to left ventricular relaxation.[154] [155] [156] [157] This method uses color M-mode Doppler echocardiography from apical windows, directed along the longitudinal axis of inflow from mitral valve to apex. The recording typically shows the two waves (early filling and atrial contraction) of flow propagation from the base toward the apex (Fig. 6-22) . The slope of the early filling wavefront has been shown to represent the presence of intraventricular gradients produced from active recoil (suction) of the ventricular myocardium.[156] [158] The velocity of streamlined
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 6
flow propagation into the ventricle (Vp ) is therefore described along the Mmode line by the slope of the color wavefront, in centimeters per second. Measurements of Vp have now been successfully obtained using either the leading edge (transition from black to color) or by tracing along any isovelocity line. More reproducible measurements can be obtained by (1) adjusting 134
Figure 6-21 A, Simultaneous mitral regurgitation Doppler velocity curve and high-fidelity left ventricular (LV) pressure curve. The time constant of relaxation (tau) is calculated from the LV pressure curve using a semilogarithmic model. B, Digitized Doppler velocity curve at 3 msec intervals in which the velocities have been converted to pressure using the modified Bernoulli equation. This new method has been described for the noninvasive assessment of tau. (From Nishimura RA, Schwartz RS, Tajik AJ, Holmes DR: Circulation 1993;88:148.)
the color scale or baseline shift to produce color aliasing, (2) tracing the slope of the first aliasing velocity line, (3) tracing the slope from the mitral leaflet tips to a position 4 cm distally into the left ventricle, and (4) avoiding intracavity flow originating before mitral opening.[159] The method may not be applicable to patients with tachycardia, arrhythmia, or heart block. Young, healthy individuals generally have Vp greater than 55 cm per second, whereas older people have Vp greater than 45 cm per second.[159] Patients with abnormal Figure 6-22 (color plate.) Color M-mode Doppler recording of diastolic flow toward the apex from the four-chamber view. The patient had severe left ventricular (LV) systolic dysfunction and a restrictive transmitral flow pattern. The inflow propagation of velocities (Vp ) is indicated by the slope of the color change during early diastole (dotted white line). The measured slope in this patient was abnormally low at 30 cm/sec.
transmitral filling patterns such as delayed relaxation, restrictive or pseudonormal, will generally have Vp less than 45 cm per second. Thus,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 6
when combined with other Doppler parameters, measurement of early filling by color M-mode may be useful in distinguishing pseudonormal from normal patterns (see Table 6-4) .[159] This method appears to be less affected by preload than transmitral or pulmonary vein flow.[160] For example, a "pseudonormal" transmitral flow pattern can be produced by increased left atrial pressure in otherwise normal patients. A blunted S wave is commonly seen in young people (especially athletes) in whom the left atrium is functioning as a "passive conduit" and can masquerade as restrictive cardiomyopathy. These situations may be clarified by examining the color M-mode slope during the early filling phase. Another important potential use for color M-mode is in the differential diagnosis of restrictive cardiomyopathy versus constrictive pericarditis.[161] Since color M-mode describes the early inflow of the blood column along the longitudinal axis, this will be rapid in constrictive physiology, whereas filling toward the apex is delayed in restriction. Doppler Tissue Imaging Another promising technique for the noninvasive evaluation of diastolic function involves the direct recording of mitral annulus motion. The technique was first described using M-mode echocardiography[162] but has since evolved to the use of pulsed-wave Doppler spectral recordings, with the sample volume located on the posterolateral portion of the mitral annulus or in the adjacent myocardium.[163] Imaging is usually performed from the apical four-chamber view to minimize the effects of translation 135
and rotation of the heart, while maximizing the longitudinal excursion of the annulus and base. Since tissue Doppler echocardiography involves the assessment of motion of the strong signal reflections (myocardium), the high pass filters are bypassed. Low gain amplification is also used to eliminate the weaker blood flow signals. The result is a triphasic signal with forward velocity toward the apex during systole, and two "away" signals during the early (Em) and the atrial (Am) phases of diastole (Fig. 6-23) . Thus, the diastolic signal appears as a mirror image of the transmitral inflow pattern. The Em wave is also referred to as Ea (for annulus) or E' in the current literature.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 6
In normal subjects, the Em wave is larger than the Am component, but the ratio falls with age. In restrictive or hypertrophic cardiomyopathies, the early myocardial relaxation phase has been shown to be reduced to less than 8 cm per second. In constrictive pericarditis, the Em values are greater than 8 cm per second, which allows separation of these two groups despite similar tramsmitral flow patterns[164] (see Table 6-4) .[159] A recent study by Sohn et al[165] has shown Em values from tissue Doppler echocardiograms to correlate well with tau as measured during catheterization and to be relatively unaffected by preload changes induced by volume infusion and nitroglycerin. Patients with pseudonormal filling were separated from normal by an Em velocity of less than 8.5 cm per second and an Em/Am ratio less Figure 6-23 Patterns of mitral annulus velocity as recorded by Doppler tissue imaging, with sampling of the septal side of the mitral annulus from the apical view. Note the changes in pattern from normal to restrictive physiology, along with corresponding transmitral flows. The Doppler tissue image may be helpful in differentiating pseudonormal from normal and restrictive transmitral flow patterns. (From Sohn, et al. J Am Coll Cardiol 1997;30:479.)
than 1, with a sensitivity of 88% and a specificity of 67%. Thus, the combination of transmitral flow patterns and color M-mode and tissue Doppler measurements may be helpful in distinguishing patients in various stages of diastolic dysfunction (see Table 6-4) . Estimation of Left Ventricular Filling Pressures As described previously, various Doppler echocardiographic indices of transmitral and pulmonary vein flow have been combined to predict left atrial pressure. Similarly, by combining transmitral E wave velocities with a preload-independent parameter such as the velocity of motion of the lateral mitral annulus (Ea), a reasonable estimate of left atrial pressure can be obtained. Nagueh et al found that an E/Ea ratio of greater than 10 correlated well with a mean pulmonary capillary wedge pressure of greater than 15 mm Hg.[166] The correlation coefficient was 0.87 in 60 patients who had hemodynamic measurements, with the relationship described by the following equation: PCWP (mm Hg) = 1.24[E/Ea] + 1.9 The authors proposed that left ventricular filling pressure can be estimated (with a 95% confidence level of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 6
136
± 7.6 mm Hg) from these two simple Doppler measurements. These findings have recently been confirmed by Ommen et al.[167] Their study consisted of 100 consecutive patients who underwent catheterization with micromanometer-tipped catheters and simultaneous Doppler measurements. A ratio of E/E' (or E/Ea) greater than 15 identified patients with elevated LVEDP greater than 12 mm Hg, whereas an E/E' ratio less than 8 accurately predicted normal pressures. Patients with ratios between 8 and 15 had widely variable ventricular diastolic pressures. The authors also noted that, in their experience, adequate signals were more often obtained from the medial or septal portion of the annulus. Although there are currently few such data available, these early and well conducted investigations are highly suggestive that the combination of tissue Doppler and mitral inflow velocities can be used to noninvasively estimate left ventricular filling pressures.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/52.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Summary Diastolic dysfunction of the left ventricle has been increasingly appreciated as an important factor in the syndrome of clinical heart failure. The need for noninvasive methods to assess left ventricular filling has led to Doppler echocardiography as a means for describing these events. After a decade of research, it is clear that various patterns of abnormal filling are readily recognized from transmitral and pulmonary vein flow velocity recordings. Although obtaining optimal measurements requires care and diligence on the part of the operator, these data can be obtained in the majority of patients. Further studies of long-term follow-up are needed to determine whether prognostic information can be obtained from Doppler data in subsets of patients. The importance of response of Doppler echocardiographic patterns to drug therapy in patients with heart failure has also not been adequately evaluated. Clearly, this is an active area of investigation and a field in evolution that promises to provide further insight into the pathophysiology and mechanisms of heart disease.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/53.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 16
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
References 1. Zile MR: Diastolic dysfunction: Detection, consequences, and treatment. Part I:
Definition and determinants of diastolic function. Mod Concepts Cardiovasc Dis 1989;58:67. 2. Sabbah HN, Stein PD: Negative diastolic pressure in the intact canine ventricle:
Evidence of diastolic suction. Circ Res 1981;49:108. 3. Zile MR: Hemodynamic determinants of echocardiographically-derived indices of
left ventricular filling. Echocardiography 1992;9:289. 4. Mirsky I: Assessment of diastolic function: Suggested methods and future
considerations. Circulation 1984;69:836. 5. Mirsky I, Pasipoularides A: Clinical assessment of diastolic function. Prog
Cardiovasc Dis 1990;32:247. 6. Starling MR, Montgomery DG, Mancini GBJ, Walsh RA: Load independence of the
rate of isovolumic relaxation in man. Circulation 1987;76:1274. 7. Weisfeldt ML, Scully HE, Frederiksen J, et al: Hemodynamic determinants of
maximum negative dP/dt and periods of diastole. Am J Physiol 1974;227:613. 8. Gaasch WH, Blaustein AS, Andrias CW, et al: Myocardial relaxation II:
Hemodynamic determinants of the rate of left ventricular isovolumic pressure decline. Am J Physiol 1980;239:41. 9. Weiss JL, Frederiksen JW, Weisfeldt ML: Hemodynamic determinants of the time
course of fall in canine left ventricular pressure. J Clin Invest 1976;58:751. 9A. Gaasch WH, Cole JS, Quinones MA, Alexander JK: Dynamic determinants of left
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 16
ventricular diastolic pressure-volume relations in man. Circulation 1975;51:317. 10. Karliner JS, Peterson KL, Ross J Jr: Left ventricular myocardial mechanics:
Systolic and diastolic function. In: Grossman W (ed): Cardiac Catheterization and Angiography, 3rd ed. Philadelphia, Lea & Febiger 1988, pp 232–245. 11. Friedman BJ, Drinkovic N, Miles H, et al: Assessment of left ventricular diastolic
function: Comparison of Doppler echocardiography and gated blood pool scintigraphy. J Am Coll Cardiol 1986;8:1348. 12. Brutsaert DL, Rademakers FE, Sys SU, et al: Analysis of relaxation in the
evaluation of ventricular function of the heart. Prog Cardiovasc Dis 1985;28:143. 13. Feigenbaum H: Echocardiographic evaluation of left ventricular diastolic function
[editorial]. J Am Coll Cardiol 1989;13:1027. 14. Takenaka K, Dabestani A, Gardin JM, et al: Left ventricular filling in hypertrophic
cardiomyopathy: A pulsed Doppler echocardiography study. J Am Coll Cardiol 1986;8:1263. 15. Stoddard MF, Pearson AC, Kern MJ, et al: Left ventricular diastolic function:
Comparison of pulsed Doppler echocardiographic and hemodynamic indexes in subjects with and without coronary artery disease. J Am Coll Cardiol 1989;13:327. 16. Rahko PS, Shaver JA, Salerni R, Uretsky BF: Noninvasive evaluation of systolic
and diastolic function in severe congestive heart failure secondary to coronary artery disease or dilated cardiomyopathy. Am J Cardiol 1986;57:1315. 17. Rokey R, Kuo LC, Zoghbi WA, et al: Determinations of parameters of left ventricular diastolic filling with pulsed Doppler echocardiography: Comparison with cineangiography. Circulation 1985;71:543. 18. Magorien DJ, Shaffer P, Bush C, et al: Hemodynamic correlates for timing
intervals, ejection rate, and filling rate derived from the radionuclide angiographic volume curve. Am J Cardiol 1984;53:567. 19. Spirito P, Maron BJ, Bonow RO: Analysis of Doppler echocardiographic and
radionuclide angiographic techniques. J Am Coll Cardiol 1986;7:518. 20. Appleton CP, Hatle LK, Popp RL: Demonstration of restrictive ventricular
physiology by Doppler echocardiography. J Am Coll Cardiol 1988;11:757. 21. Stoddard MF, Seegar J, Liddell NE, et al: Prolongation of isovolumetric relaxation
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 16
time as assessed by Doppler echocardiography predicts doxyrubicin-induced systolic dysfunction in humans. J Am Coll Cardiol 1992;20:62. 22. DeMaria AN, Wisenbaugh T: Identification and treatment of diastolic dysfunction:
Role of transmitral Doppler recordings [editorial]. J Am Coll Cardiol 1987;9:1106. 23. Fisher DC, Sahn DJ, Friedman MT, et al: The mitral valve orifice method for
noninvasive two-dimensional echo Doppler determination of cardiac output. Circulation 1983;67:872. 24. Holen J, Aaslid R, Landmark K, Simonsen S: Determination of pressure gradient in
mitral stenosis with a noninvasive ultrasound Doppler technique. Acta Med Scand 1976;199:455. 25. Curtois M, Vered Z, Barzilai B, et al: The transmitral pressure-flow velocity
relation, effect of abrupt preload reduction. Circulation 1988;78:1459. 26. Keren G, Meisner JS, Sherez J, Yellin EL: Interrelationship of mid-diastolic mitral
valve motion, pulmonary venous flow, and transmitral flow. Circulation 1986;74:36. 27. Choong CY, Herrmann HC, Weyman AE, Fifer MA: Left ventricular diastolic
pressure-volume relation in man derived from Doppler and two-dimensional echocardiography [abstract]. Circulation 1986;74:II–46. 28. Drinkovic N, Wisenbaugh T, Kwan OL, et al: Assessment of diastolic left
ventricular function by Doppler: Comparison with catheterization measurements [abstract]. J Am Coll Cardiol 1986;7:227A. 137
29. Kitzman D, Sheikh KH, Beere PA, et al: Age related alterations of Doppler left
ventricular filling in normal subjects are independent of left ventricular mass, heart rate, contractility and loading conditions. J Am Coll Cardiol 1991;18:1243. 30. Douglas PS, Berko BA, Iolo A, Reichek N: Variable responses of mitral valve
motion and flow in systemic hypertension and in idiopathic dilated cardiomyopathy. Am J Cardiol 1987;60:363. 31. Graettinger WF, Weber MA, Gardin JM, Knoll ML: Diastolic blood pressure as a
determinant of Doppler left ventricular filling indexes in normal adolescents. J Am Coll Cardiol 1987;10:1280.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 16
32. Gardin JM, Rohan MK, Davidson DM, et al: Doppler transmitral flow velocity
parameters: Relationship between age, body surface area, blood pressure and gender in normal subjects. Am J Noninvas Cardiol 1987;1:3. 33. Bryg RJ, Pearson AC, Williams GA, Labovitz AJ: Left ventricular systolic and
diastolic flow abnormalities determined by Doppler echocardiography in obstructive hypertrophic cardiomyopathy. Am J Cardiol 1987;59:925. 33A. Cacciapuoti F, D'Avino M, Lanca D, et al: Progressive impairment of left
ventricular diastolic filling with advancing age: A Doppler echocardiographic study. J Am Geriatr Soc 1992;40:245. 34. Appleton CP, Hatle LK: The natural history of left ventricular filling
abnormalities: Assessment by two-dimensional and Doppler echocardiography. Echocardiography 1992;9:437. 35. Appleton CP, Hatle LK, Popp RL: Relation of transmitral flow velocity patterns to
left ventricular diastolic function: New insights from a combined hemodynamic and Doppler echocardiographic study. J Am Coll Cardiol 1988;12:426. 36. Klein AL, Hatle LK, Burstow DJ, et al: Doppler characterization of left ventricular
diastolic function in cardiac amyloidosis. J Am Coll Cardiol 1989;13:1017. 37. Ishida Y, Meisner JS, Tsujioka K, et al: Left ventricular filling dynamics: Influence
of left ventricular relaxation and left atrial pressure. Circulation 1986;74:187. 38. DeMaria AN, Wisenbaugh T, Smith MD, et al: Doppler echocardiographic
evaluation of diastolic dysfunction. Circulation 1991;84(Suppl I):I–288. 39. Shapiro SM, Bersohn MM, Laks MM: In search of the holy grail: The study of
diastolic ventricular function by the use of Doppler echocardiography. J Am Coll Cardiol 1991;17:517. 40. Choong CY, Herrmann HC, Weyman AE, Fifer MA: Preload dependence of
Doppler derived indexes of left ventricular diastolic function in humans. J Am Coll Cardiol 1987;10:800. 41. Nishimura R, Abel M, Hatle L, Tajik A: Relationship of pulmonary vein to mitral
flow velocities by transesophageal Doppler echocardiography: Effect of different loading conditions. Circulation 1990;81:1488. 42. Bryg RJ, Williams GA, Labovitz AJ: Effect of aging on left ventricular diastolic
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 16
filling in normal subjects. Am J Cardiol 1987;59:971. 43. Miyatake K, Okamoto M, Kinowhita N, et al: Augmentation of atrial contribution
of left ventricular inflow with aging as assessed by intracardiac Doppler flowmetry. Am J Cardiol 1984;53:586. 44. Sartori MP, Quinones MA, Kuo LC: Relation of Doppler derived left ventricular filling parameters to age and radius/thickness ratio in normal and pathologic states. Am J Cardiol 1987;59:1179. 45. Herzog CA, Elsperger KJ, Manoles M, et al: Effect of atrial pacing on left
ventricular diastolic filling measured by pulsed Doppler echocardiography [abstract]. J Am Coll Cardiol 1987;9(Suppl A):197A. 46. Harrison MR, Clifton ED, Pennell A, DeMaria AN: Effect of heart rate on left
ventricular diastolic transmitral flow velocity patterns assessed by Doppler echocardiography in normal subjects. Am J Cardiol 1991;67:622. 47. Nishimura RA, Abel MD, Hatle LK, Tajik AJ: Assessment of diastolic function of
the heart: Background and current applications of Doppler echocardiography. Part II. Clinical studies. Mayo Clin Proc 1989;64:181. 48. Berk MR, Xie GY, Kwan OL, et al: Reduction of left ventricular preload by lower
body negative pressure alters Doppler transmitral filling patterns. J Am Coll Cardiol 1990;16:1387. 49. Choong CY, Abascal VM, Thomas JD, et al: Combined influence of ventricular
loading and relaxation on the transmitral flow velocity profile in dogs measured by Doppler echocardiography. Circulation 1988;78:672. 50. Curtois M, Mechem C, Barzilai B, Ludbrook P: Factors related to end-systolic
volume are important determinants of peak entry diastolic transmitral flow velocity. Circulation 1992;83:1132. 51. Miki S, Yokota Y, Seo T, Yokoyama M: Dependence of Doppler
echocardiographic transmitral early peak velocity on left ventricular systolic function in coronary artery disease. Am J Cardiol 1991;67:475. 52. Manning WJ, Leeman DE, Gotch PJ, Come PC: Pulsed Doppler evaluation of atrial mechanical function after electrical cardioversion of atrial fibrillation. J Am Coll Cardiol 1989;13:617. 53. Grimm RA, Stewart WJ, Maloney JD, et al: Impact of electrical cardioversion of
atrial fibrillation on atrial appendage function and spontaneous echo contrast:
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 16
Characterization by simultaneous transesophageal echocardiography. J Am Coll Cardiol 1993;22:1359. 54. Riggs TW, Snider AR: Respiratory influence on right and left ventricular diastolic
function in normal children. Am J Cardiol 1989;63:858. 55. Dabestani A, Takenaka K, Allen B, et al: Effects of spontaneous respiration on left ventricular filling as assessed by Doppler echocardiography. Am J Cardiol 1988;61:1356. 56. Gardin JM, Debastani A, Takenaka K, et al: Effect of imaging view and sample
volume location on evaluation of mitral flow velocity pulsed by Doppler echocardiography. Am J Cardiol 1986;57:1335. 57. Drinkovic N, Smith MD, Wisenbaugh T, et al: Influence of sampling site upon the
ratio of atrial to early diastolic transmitral flow velocities by Doppler [abstract]. J Am Coll Cardiol 1987;9:16A. 58. Ding ZP, Oh JK, Klein AL, Tajik AJ: Effect of sample volume location on
Doppler-derived transmitral inflow velocity values. J Am Soc Echocardiogr 1991;4:451. 59. Samstad S, Torp HG, Linker DL, et al: Cross-sectional early mitral flow velocity
profiles from color Doppler. Br Heart J 1989;62:177. 60. Myreng Y, Smiseth DA: Assessment of left ventricular relaxation by Doppler
echocardiography: Comparison of isovolumic relaxation time and transmitral flow velocities with time constant of isovolumic relaxation. Circulation 1990;81;260. 61. Castello R, Pearson A, Lenzen P, Labovitz A: Evaluation of pulmonary venous
flow by transesophageal echocardiography in subjects with a normal heart: Comparison with transthoracic echocardiography. J Am Coll Cardiol 1991;18:65. 62. Keren G, Sherez J, Megedish R, et al: Pulmonary venous flow pattern—its
relationship to cardiac dynamics: A pulsed Doppler echocardiographic study. Circulation 1985;71:1105. 63. Rossvoll O, Hatle LK: Pulmonary venous flow velocities by transthoracic
ultrasound: Relation to left ventricular diastolic pressures. J Am Coll Cardiol 1993;21:1687. 64. Smallhorn JF, Freedom RM, Olley PM: Pulsed Doppler echocardiographic
assessment of extraparenchymal pulmonary vein flow. J Am Coll Cardiol 1987;9:573.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 16
65. Kuecherer HF, Kusumoto F, Muhiudeen IA, et al: Pulmonary venous flow patterns
by transesophageal echocardiography: Relation to parameters of left ventricular systolic and diastolic function. Am Heart J 1991;122:1683. 66. Kuecherer H, Muhiudeen IA, Kusumoto FM, et al: Estimation of mean left atrial
pressure from transesophageal pulsed Doppler echocardiography of pulmonary venous flow. Circulation 1990;82:1127. 67. Brunazzi MC, Chirillo F, Pasqualini M, et al: Estimation of left ventricular
diastolic pressures from precordial pulsed-Doppler analysis of pulmonary venous and mitral flow. Am Heart J 1994;128:293. 68. Channer S, Wilde P, Culling W, Jones JV: Estimation of left ventricular end
diastolic pressure by pulsed Doppler ultrasound. Lancet 1986;3:1005. 69. Masuyama T, Lee JM, Tamai M, et al: Pulmonary venous flow pattern as assessed
with transthoracic pulsed Doppler echocardiography in subjects without cardiac disease. Am J Cardiol 1991;67:1936. 70. Klein AL, Tajik AJ: Doppler assessment of pulmonary venous flow in healthy
subjects and in patients with heart disease. J Am Soc Echocardiogr 1991;4:379. 71. Arakawa M, Akamatsu S, Terazawa E, et al: Age-related increase in systolic
fraction of pulmonary vein flow velocity-time integral from transesophageal echocardiography in subjects without cardiac disease. Am J Cardiol 1992;70:1190. 138
72. Hoit B, Shao Y, Gabel M, Walsh R: Influence of loading conditions and contractile
state on pulmonary venous flow: Validation of Doppler velocimetry. Circulation 1992;86:651. 73. Castello R, Pearson AC, Lenzen P, Labovitz A: Effect of mitral regurgitation on
pulmonary venous velocities derived from transesophageal echocardiography colorguided pulsed Doppler imaging. J Am Coll Cardiol 1991;17:1499. 74. Klein A, Obarski TB, Stewart WJ, et al: Transesophageal Doppler
echocardiography of pulmonary venous flow: A new marker of mitral regurgitation severity. J Am Coll Cardiol 1991;18:518.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 16
75. Rajagopalan B, Friend JA, Stollard T, Lee GJ: Blood flow in pulmonary veins: III. Simultaneous measurements of their dimensions, intravascular pressure and flow. Cardiovasc Res 1979;13:684. 76. Topol EJ, Taill TA, Fortuin NJ: Hypertensive hypertrophic cardiomyopathy of the
elderly. N Engl J Med 1985;312:277. 77. Dougherty AH, Nacarelli GV, Gray EL, et al: Congestive heart failure with normal
systolic function. Am J Cardiol 1984;54:778. 78. Harizi RC, Bianco JA, Alpert JS: Diastolic function of the heart in clinical
cardiology. Arch Intern Med 1988;148:99. 79. Soufer R, Wohlgelertner D, Vita N, et al: Intact systolic left ventricular function in
clinical congestive heart failure. Am J Cardiol 1985;55:1032. 80. Appleton CP: Doppler assessment of left ventricular diastolic function: The
refinements continue [editorial]. J Am Coll Cardiol 1993;21:1697. 81. Xie G, Berk MR, Smith MD, et al: Prognostic value of Doppler transmitral flow
patterns in patients with congestive heart failure. J Am Coll Cardiol 1994;24:132. 82. Bahler RC, Vrobel TR, Martin RL: The relation of heart rate and shortening
fraction to echocardiographic indices of left ventricular relaxation in normal subjects. J Am Coll Cardiol 1983;2:926. 83. Abe H, Yokouchi M, Deguchi F, et al: Measurement of left atrial systolic time
intervals in hypertensive patients using Doppler echocardiography: Relation to fourth heart sound and left ventricular wall thickness. J Am Coll Cardiol 1988;11:800. 84. Pearson AC, Labovitz AJ, Mrosek D, et al: Assessment of diastolic function in
normal and hypertrophied hearts: Comparison of Doppler echocardiography and Mmode echocardiography. Am Heart J 1987;113:1417. 85. Ren JF, Pancholy SB, Iskandrian AS, et al: Doppler echocardiographic evaluation
of the spectrum of left ventricular diastolic dysfunction in essential hypertension. Am Heart J 1994;127:906. 86. Marabotti C, Genovesi-Ebert A, Ghione S, et al: Diastolic function in the different
patterns of left ventricular adaptation to essential hypertension. Int J Cardiol 1994;44:73.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 16
87. Kuo LC, Quinones MA, Rokey R, et al: Quantitation of atrial contribution to left
ventricular filling by pulsed Doppler echocardiography and the effect of age in normal and diseased hearts. Am J Cardiol 1987;59:1174. 88. Otto CM, Pearlman AS, Amsler LC: Doppler echocardiographic evaluation of left
ventricular diastolic filling in isolated valvular aortic stenosis. Am J Cardiol 1989;63:313. 89. Pearson AC, Gudipati CV, Labovitz AJ: Systolic and diastolic flow abnormalities
in elderly patients with hypertensive hypertrophic cardiomyopathy. J Am Coll Cardiol 1988;12:989. 90. Grossman F, Orem S, Messerli F: Left ventricular filling in the systemic
hypertension of obesity. Am J Cardiol 1991;68:57. 91. Chakko S, Maya M, Allison MD, et al: Abnormal left ventricular diastolic filling in
eccentric left ventricular hypertrophy of obesity. Am J Cardiol 1991;68:95. 92. Kapuka GK, Seto S, Mori H, et al: Reversal of diastolic dysfunction in borderline
hypertension by long-term medical treatment: Longitudinal evaluation by pulsedDoppler echocardiography. Am J Hypertens 1993;6:547. 93. Esper RJ, Burrieza OH, Cacharron JL, et al: Left ventricular mass regression and
diastolic function improvement in mild and moderate hypertensive patients treated with lisinopril. Cardiology 1993;83:76. 94. Stoddard MF, Vandormael MG, Pearson AC, et al: Immediate and short-term
effects of aortic balloon valvuloplasty on left ventricular diastolic function and filling in humans. J Am Coll Cardiol 1989;14:1218. 95. Hatle L: Doppler echocardiographic evaluation of diastolic function in
hypertensive cardiomyopathies. Eur Heart J 1993;14(Suppl J):88. 96. Maron BJ, Spirito P, Green KJ, et al: Noninvasive assessment of left ventricular
diastolic function by pulsed Doppler echocardiography in patients with hypertrophic cardiomyopathy. J Am Coll Cardiol 1987;10:733. 97. Lewis JF, Spirito P, Pelliccia A, Maron BJ: Usefulness of Doppler
echocardiographic assessment of diastolic filling in distinguishing "athlete's heart" from hypertrophic cardiomyopathy. Br Heart J 1992;68:296. 98. Bonow RO, Frederick TM, Bacharach SL, et al: Atrial systole and left ventricular
filling in hypertrophic cardiomyopathy: Effect of verapamil. Am J Cardiol 1983;51:1386.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 16
99. Werner GS, Schaefer C, Dirks R, et al: Prognostic value of Doppler echocardiographic assessment of left ventricular filling in idiopathic dilated cardiomyopathy. Am J Cardiol 1994;73:792. 100. Lavine S, Arends D: Importance of the left ventricular filling pressure on diastolic
filling in idiopathic dilated cardiomyopathy. Am J Cardiol 1989;64:61. 101. Vanoverschelde JL, Raphael DA, Robert AR, Cosyns JR: Left ventricular filling
in dilated cardiomyopathy: Relation to functional class and hemodynamics. J Am Coll Cardiol 1990;15:1288. 102. Xie GY, Berk MR, Smith MD, et al: The role of the left atrium in heart failure: Assessment by transmitral and pulmonary vein Doppler [abstract]. J Am Soc Echocardiogr 1993;6:34. 103. Takenaka K, Dabestani A, Gardin JM, et al: Pulsed Doppler echocardiographic
study of left ventricular filling in dilated cardiomyopathy. Am J Cardiol 1986;58:143. 104. Makhoul N, Hasanein J, Dagan T, et al: Doppler diastolic transmitral flow
patterns in severe heart failure: Response to controlled changes in filling pressure using intravenous isosorbide dinitrate. Cardiology 1994;85:235. 105. Xie G, Berk MR, Smith MD, DeMaria AN: Relationship of Doppler transmitral
flow patterns to functional status in patients with congestive heart failure. Am Heart J 1996;131:766. 106. Basnight MA, Gonzalez MS, Kershenovitch SC, Appleton CP: Pulmonary venous
flow velocity: Relation to hemodynamics, mitral flow velocity and left atrial volume and ejection fraction. J Am Soc Echocardiography 1991;4:547. 107. Hatle LK, Appleton CP, Popp RL: Differentiation of constrictive pericarditis and
restrictive cardiomyopathy by Doppler echocardiography. Circulation 1989;79:357. 108. Klein AL, Hatle LK, Taliercio CP, et al: Prognostic significance of Doppler
measures of diastolic function in cardiac amyloidosis. Circulation 1991;83:808. 109. Pandian NG, Wang SS, McInerney K, et al: Doppler echocardiography in cardiac
tamponade: Abnormalities in tricuspid and mitral flow response to respiration in experimental and clinical tamponade [abstract]. J Am Coll Cardiol 1985;5:485A. 110. Appleton CP, Hatle LK, Popp RL: Cardiac tamponade and pericardial effusion:
Respiratory variation in transvalvular flow velocities studied by Doppler
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 16
echocardiography. J Am Coll Cardiol 1988;11:1020. 111. Gonzalez MS, Basnight MA, Appleton CP: Experimental pericardial effusion:
Relation of abnormal respiratory variation in mitral flow velocity to hemodynamics and diastolic right heart collapse. J Am Coll Cardiol 1991;17:239. 112. Gillam LD, Guyer DE, Gibson TE, et al: Hydrodynamic compression of the right
atrium: A new echocardiographic sign of cardiac tamponade. Circulation 1983;68:294.
113. Armstrong WI, Schilt BI, Helser DJ, et al: Diastolic collapse of the right ventricle
with cardiac tamponade: An echocardiographic study. Circulation 1982;65:1491. 114. Picard MH, Sanfilippo AJ, Newell JB, et al: Quantitative relation between increased intrapericardial pressure and Doppler flow velocities during experimental cardiac tamponade. J Am Coll Cardiol 1991;18:234. 115. Wind BE, Snider RA, Buda AJ, et al: Pulsed Doppler assessment of left
ventricular diastolic filling in coronary artery disease before and immediately after coronary angioplasty. Am J Cardiol 1987;59:1041. 116. Labovitz AJ, Lewen MK, Kern M, et al: Evaluation of left ventricular systolic and
diastolic dysfunction during transient myocardial ischemia produced by angioplasty. J Am Coll Cardiol 1987;10:748. 139
117. Bonow RO, Bacharach SL, Green MV, et al: Impaired left ventricular diastolic
filling in patients with coronary artery disease: Assessment with radionuclide angiography. Circulation 1981;64:315. 118. Masuyama T, Kodania K, Nakatani S, et al: Effects of changes in coronary
stenosis on left ventricular diastolic filling assessed with pulsed Doppler echocardiography. J Am Coll Cardiol 1988;11:744. 119. Drinkovic N, Wisenbaugh T, Nissen SE, et al: Sensitivity and specificity of
transmitral flow velocity measurements in detecting impaired left ventricular compliance [abstract]. Circulation 1986;74:II-46. 120. El-Said EM, Roelandt JRTC, Fioretti PM, et al: Abnormal left ventricular early
diastolic filling during dobutamine stress Doppler echocardiography is a sensitive
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 16
indicator of significant coronary artery disease. J Am Coll Cardiol 1994;24:1618. 121. Fujii J, Karzaki Y, Sawada H, et al: Noninvasive assessment of left and right
ventricular filling in myocardial infarction with a 2-dimensional Doppler echocardiographic method. J Am Coll Cardiol 1985;5:1155. 122. Isobe M, Yazaki Y, Takaku F, et al: Right ventricular filling detected by pulsed Doppler echocardiography during the convalescent stage of inferior wall acute myocardial infarction. Am J Cardiol 1987;59:1245. 123. Johannessen K, Cerqueria M, Stratton J: Influence of myocardial infarction size
on radionuclide and Doppler echocardiographic measurements of diastolic function. Am J Cardiol 1990;65:692. 124. Myreng V, Myhre E: Effects of verapamil on left ventricular relaxation and filling
dynamics in coronary artery disease: A study by pulsed Doppler echocardiography. Am Heart J 1989;117:870. 125. Myreng Y, Ihlen H, Nitter-Hauge SL: Effects of beta-adrenergic blockade on left
ventricular relaxation and filling dynamics in coronary artery disease: A pulsed Doppler echocardiographic study. Eur Heart J 1988;9:1167. 126. Manning WJ, Shannon RP, Santinga JA, et al: Reversal of changes in left
ventricular diastolic filling associated with normal aging using diltiazem. Am J Cardiol 1991;67:894. 127. Caramelli B, dos Santos RD, Abensur H, et al: Beta-blocker infusion did not
improve left ventricular diastolic function in myocardial infarction: A Doppler echocardiography and cardiac catheterization study. Clin Cardiol 1993;16:809. 128. Nishimura RA, Schwartz RS, Holmes DR, Tajik AJ: Failure of calcium channel
blockers to improve ventricular relaxation in humans. J Am Coll Cardiol 1993;21:182.
129. Ross J Jr: Acute displacement of the diastolic pressure volume curve of the left
ventricle: Role of the pericardium and the right ventricle. Circulation 1979;59:32. 130. Sonnenblick EH: The structural basis and importance of restoring forces and
elastic recoil for the filling of the heart. Eur Heart J 1980;6(Suppl A):107. 131. Glantz SA, Misbach GA, Moores WY, et al: The pericardium substantially affects
the left ventricular diastolic pressure-volume relationship in the dog. Circ Res 1978;42:433.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 16
132. Alderman EL, Glantz SA: Acute hemodynamic interventricular shift of the
diastolic pressure-volume curve in man. Circulation 1976;54:662. 133. Louie EK, Rich S, Brundage BH: Doppler echocardiographic assessment of
impaired left ventricular filling in patients with right ventricular pressure overload due to primary pulmonary hypertension. J Am Coll Cardiol 1986;8:1298. 134. Louie EK, Rich S, Levitsky S, Brundage B: Doppler echocardiographic
demonstration of the differential effects of right ventricular pressure and volume overload on left ventricular geometry and filling. J Am Coll Cardiol 1992;19:84. 135. Stojnic BB, Brecker SJD, Xiao HB, et al: Left ventricular filling characteristics in
pulmonary hypertension: A new mode of ventricular interaction. Br Heart J 1992;68:16. 136. Dubroff JM, Clark WB, Wong CYH, et al: Changes in left ventricular mass
associated with the onset of acute rejection after cardiac transplantation. Heart Transplant 1983;3:103. 137. Paulsen W, Maid N, Sagar K, et al: Left ventricular function of heart allografts
during acute rejection: An echocardiographic assessment. J Heart Transplant 1985;4:525. 138. Greenberg ML, Uretsky BF, Reddy S, et al: Long-term hemodynamic follow-up
of cardiac transplant patients treated with cyclosporine and prednisone. Circulation 1985;71:487. 139. Popp RL, Schroeder JS, Stinson EB, et al: Ultrasonic studies for the early
detection of acute cardiac rejection. Transplantation 1971;11:543. 140. Dawkins KD, Oldershaw PJ, Billingham ME, et al: Changes in diastolic function
as noninvasive markers of cardiac allograft rejection. Heart Transplant 1984;3:286. 141. Valantine HA, Appleton CP, Hatle LK, et al: A hemodynamic and Doppler
echocardiographic study of ventricular function in long-term cardiac allograft recipients. Circulation 1989;79:66. 142. Boucek MM, Mathis CM, Kanakriyeh MS, et al: Serial echocardiographic
evaluation of cardiac graft rejection after infant heart transplantation. J Heart Lung Transplant 1993;12:824. 143. Xie GY, Morris EJ, Mattson MD, et al: Value of right and left ventricular
diastolic parameters by Doppler echo to predict cardiac rejection after transplantation
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 16
[abstract]. J Am Coll Cardiol 1993;21:41A. 144. Upton MT, Gibson DG: The study of left ventricular filling from digitized
echocardiograms. Prog Cardiovasc Dis 1978;20:359. 145. Shimizu G, Zile MR, Blaustein AS, Gaasch WH: Left ventricular chamber filling
and midwall lengthening in patients with left ventricular hypertrophy: Overestimation of fiber velocities by conventional midwall measurements. Circulation 1985;71:266. 146. Geiser EA, Conetta DA, Limacher MC, et al: A second generation computer-
based edge detection algorithm for short-axis, two-dimensional echocardiographic images: Accuracy and improvement in interobserver variability. J Am Soc Echocardiogr 1990;3:79. 147. Perez JE, Waggoner AD, Barzilai B, et al: On-line assessment of ventricular
function by automatic boundary detection and ultrasonic backscatter imaging. J Am Coll Cardiol 1992;19:313. 148. Gorcsan J III, Schulman DS, Koch L, et al: Echocardiographic automated border
detection derived left ventricular ejection fraction: Comparison with radionuclide angiography [abstract]. Circulation 1991;84(Suppl II):II-585. 149. Sapin PM, Kwan OL, Xie GY, et al: The assessment of left ventricular filling
dynamics using an on-line automatic border detection algorithm: Comparison with cineangiography. Echocardiography 1995;12:559. 150. Chenzbraun A, Pinto FJ, Popylisen S, et al: Comparison of acoustic quantification
and Doppler echocardiography in assessment of left ventricular diastolic variables. Br Heart J 1993;70:448. 151. Smith MD, Xie G, Sapin PM, et al: Factors affecting the determination of left
ventricular area by acoustic quantitation [abstract]. J Am Coll Cardiol 1992;19:199A. 152. Chen C, Rodriquez L, Levine RA, et al: Noninvasive measurement of the time
constant of left ventricular relaxation using the continuous-wave Doppler velocity profile of mitral regurgitation. Circulation 1992;86:272. 153. Nishimura RA, Schwartz RS, Tajik AJ, Holmes DR: Noninvasive measurement of
rate of left ventricular relaxation by Doppler echocardiography: Validation with simultaneous cardiac catheterization. Circulation 1993;88:146. 154. Brun P, Tribuoilloy C, Duval AM, et al: Left ventricular flow propagation during
early filling is related to wall relaxation: A color M-mode Doppler analysis. J Am Coll Cardiol 1992;20:420.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 15 di 16
155. Stugaard M, Smiseth DA, Risoe C, Ihlen H: Intraventricular early diastolic filling
during acute myocardial ischemia: Assessment by multigated color M-mode Doppler echocardiography. Circulation 1993;88:2705. 156. Curtois M, Ludbrook PA: Intraventricular pressure gradients during relaxation
and filling. In Gaasch WH, Le Winter MM (eds): Left Ventricular Diastolic Dysfunction and Heart Failure. Philadelphia, Lea and Febiger, 1994, p 150. 157. Greenberg NL, Vandervoort PM, Thomas JD: Estimation of diastolic
intraventricular pressure gradients from color M-mode Doppler spatiotemporal velocities: Analytical Euler equation solution. Los Alamitos, CA, Computers in Cardiology 1994, IEEE Computer Society Press, 1995, p 465. 158. Greenberg NL, Vandervoort PM, Thomas JD: Instantaneous diastolic transmitral
pressure differences from color Doppler M-mode echocardiography. Am J Physiol 1996;271:H-1267. 159. Garcia MJ, Thomas J, Klein AL: New Doppler echocardiographic applications for
the study of diastolic function. J Am Coll Cardiol 1998;32:865. 140
160. Takatsuji H, Mikami T, Urasawa K, et al: A new approach for evaluation of left ventricular diastolic function: Spatial and temporal analysis of left ventricular filling flow propagation by color M-mode Doppler echocardiography. J Am Coll Cardiol 1996;27:365. 161. Rodriguez L, Ares MA, Vandervoort PM, et al: Does color M-mode flow
propagation differentiate between patents with restrictive vs. constrictive physiology? J Am Coll Cardiol 1996;27:268A. 162. Gibson DG, Prewitt TA, Brown DJ: Analysis of left ventricular wall movement
during isovolumic relaxation and its relation to coronary artery disease. Br Heart J 1976;38:1010. 163. Isaaz K, Munoz del Romeral L, Lee E, Schiller NB: Quantitation of the motion of
the cardiac base in normal subjects by Doppler echocardiography. J Am Soc Echocardiogr 1993;6:166. 164. Garcia MJ, Rodriguez L, Ares MA, et al: Differentiation of constrictive
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 16 di 16
pericarditis from restrictive cardiomyopathy: Assessment of left ventricular diastolic velocities in the longitudinal axis by Doppler tissue imaging. J Am Coll Cardiol 1996;27:108. 165. Sohn DW, Chai IH, Lee DJ, et al: Assessment of mitral annulus velocity by
Doppler tissue imaging in the evaluation of left ventricular diastolic function. J Am Coll Cardiol 1997;30:474–80. 166. Nagueh SF, Middleton KJ, Kopelen HA, et al: Doppler tissue imaging: A
noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures. J Am Coll Cardiol 1997;30:1527. 167. Ommen SR, Nishimura RA, Appleton CP, et al: Clinical utility of Doppler
echocardiography and tissue Doppler imaging in the estimation of left ventricular filling presures: A comparative simultaneous Doppler-catheterization study. Circulation 2000;102:1788.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/54.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
141
Chapter 7 - Two-Dimensional Echocardiographic Digital Image Processing and Approaches to Endocardial Edge Detection Hans G. Bosch MSc Johan H.C. Reiber PhD
Digital image processing techniques nowadays can be found in any ultrasonography machine or offline analysis system. Moreover, ultrasonography machines have evolved from mainly analog, video-type technology into fully digital, computer-like systems. Digital image storage and digital processing of echocardiographic images, both for image enhancement and for analysis, are widely practiced. Some forms of automated image analysis and automated border detection (ABD) techniques (also known as edge detection, border delineation, or edge finding) are commercially available. However, automated border detection is still in the process of development. Many issues remain to be solved, but important breakthroughs can be expected soon. Automated border detection can potentially supply the echocardiologist with quantitative, less subjective tools for research and clinical practice. However, ultrasonography is a difficult imaging modality for interpretation, for both humans and computers. Frequently, unrealistic expectations as
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
well as unfounded denunciation of the possibilities of image processing and automated analysis are encountered. In this chapter, we want to provide the clinician with some insight into the background of different techniques and supply some practical guidelines for 142
the choice and use of techniques and their possibilities and limitations.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/55.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Digital Image Processing and Endocardial Edge Detection: Why and When? Digital image processing concerns all manipulation of images by a computer. In a more limited sense, it refers to enhancement or analysis of images. Image enhancement aims at improvement of images, for visual interpretation or for further automated analysis. This can range from a simple contrast adjustment up to sophisticated filtering. The user can apply these when all or parts of an image need improved visualization. Image analysis generally involves the derivation of some quantitative measures or parameters from images. In a narrower sense, this often refers to automatic localization and outlining (edge detection, border detection) of certain structures. In echocardiography, the left ventricular (LV) endocardium is of prime interest. Outlining of the LV endocardial border is necessary for quantitative measurements of LV cavity area and calculation of volume, local wall displacement and velocity, and so on. Combination with the epicardial border allows calculation of wall thickness and LV mass. Besides quantitative measurements based on delineated areas or caliper distances, visual estimation of parameters (such as ejection fraction) or semiquantitative classification (e.g., wall motion scoring for stress echocardiography) still plays an important role in clinical practice. Eyeballing can be done fast, without much ado, and some experts reach an admirable accuracy. In general, however, it is inaccurate, irreproducible, and hard to learn.[1] Visual estimation of quantifiable measures should be discouraged for any purpose beyond a rough classification, whenever a quantitative alternative is present. Quantitative analysis is advisable when repetitive interpretations are done, when more subtle differences are sought, when interpretation experience is limited, and whenever scientific research is the goal.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
The classic method of outlining the borders is manual drawing. Any ultrasonography machine or offline analysis system has facilities for this, using a mouse, trackball, or similar device. Manual drawing, however, is known to have high inter- and intraobserver variability; it is strenuous and time consuming for the operator and requires expertise and dexterity. Drawing of all frames in the cardiac cycle, over multiple cycles and over multiple stages (as in stress echocardiography), is especially hard to perform practically, in terms of both consistency and workload. Automated Border Detection (ABD) in principle can provide solutions to these problems. Potentially, any measurement that requires manual drawing of borders or indication of landmark points may benefit from automated detection techniques. Moreover, if ABD can be performed online and in real time, it opens possibilities for real-time monitoring of parameters such as LV area and volume. Procedures such as stress echocardiography that currently rely totally on visual scoring of wall motion and comparison between different stages could benefit enormously from automated analysis; the lack of quantification and the large inter- and intraobserver and interinstitution variabilities[2] are perceived as important limitations. No practical automated method for stress echocardiographic analysis is available yet, but some promising developments are described here.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/56.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 4
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Digital Image Storage, Communication, and Compression The basis of digital image processing and analysis is the availability of images in digital form. Digital image storage and related subjects are discussed in more detail in the chapters on the digital echocardiography laboratory; in this chapter, an overview of properties of importance for image processing is given. The generation of ultrasonographic images, including ultrasound physics, radiofrequency signal processing, scan conversion, and the instrumentation of ultrasonography machines, is beyond the scope of this chapter. Excellent descriptions on these subjects can be found in many handbooks.[3] [4] [5] [6] Digital Images Digital images are bitmaps, large rectangular matrices of dots or pixels (picture elements) in which the brightness (or color) at each position is represented by a numeric (digital) value. Brightness level is also referred to as intensity or gray value. Typical sizes for echo images are 640 × 480 × 24-bit, equivalent to an NTSC color image, or 768 × 576 × 8-bit for a PAL black and white image. NTSC and PAL are U.S. and European video standards. This should be read as 640 columns by 480 rows of pixels (width X height), 24 bits per pixel. The composing colors red, green, and blue are each coded by 8 bits, giving 256 levels per color, allowing 16.8 million color combinations. A cineloop or movie is a sequence of such images, typically at a frame-rate of 30 or 25 images per second. A digital representation makes it possible to store images as data files and process these in a computer—hence, digital image processing. Analog images, as they are used in TVs and VCRs, consist of a continuously varying electrical signal (the video signal) that represents the brightness along horizontal lines in the image. Such a signal is subject to noise and degradation when it is transmitted over a line or stored on a VCR tape. On the other hand, digital images do not degrade when copied, transmitted, or stored for longer periods. Digital images can be stored on digital media such as floppy disks,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 4
MOD, CD-ROM, or DVD, transported over networks, stored in large databases, and linked with any other patient information. The main drawback is still the huge amount of data storage that is involved—a single VCR tape of 2 hours carries the equivalent of about 200 gigabytes of uncompressed color images. With image compression and selection, we can limit the storage requirements considerably, but still we cannot use digital storage simply instead of a VCR now. Inside the ultrasonography system, echo images are 143
always created as digital images. Frame-rates and image size can be very different from the typical video values. For display on a monitor and recording on VCR, these digital images are converted into an analog video signal. Not all ultrasonography machines support the storage or communication of digital images, and some can only store single frames, not cineloops. For digital image processing and analysis, digital images are a prerequisite. If only analog video output or VCR tape is available, it is possible to redigitize the analog signal with the help of computer devices named frame grabbers or video digitizers. Note that this introduces unwanted image deterioration in the form of noise and jitter, loss of spatial and temporal detail, loss of separation between image, graphics and color overlays, and loss of additional information such as calibration and patient information. Storage Formats and Image Communication DICOM
The current method of choice for digital image storage and exchange is DICOM (Digital Imaging and Communications in Medicine [7] ). DICOM 3.0 is a generally accepted international standard for medical images proposed by the DICOM committee, a cooperation of professional organizations such as the American College of Radiology, the American College of Cardiology, and the European Society of Cardiology and experts from the medical imaging industry and standardization organizations such as the National Electrical Manufacturers Association. Originally developed for radiography, DICOM now encompasses extensions for most image modalities, including ultrasonography, magnetic resonance imaging, computed tomography, x-ray angiography, and nuclear imaging. The
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 4
DICOM standard is still being extended and improved to better support stress echocardiography, three-dimensional echocardiography, ultrasonography, and others. DICOM should improve the exchangeability of all medical image data. As its name implies, DICOM is a communication standard rather than a file format—it defines the way in which medical imaging devices such as ultrasonography machines, Picture Archiving and Communications Systems (PACS) servers, and printers communicate to transport, store, retrieve, find, or print images and associated patient information. All major manufacturers have committed themselves to support DICOM; eventually, this should allow easy networking in multivendor environments, workable PACS systems, and easy and transparent offline viewing and analysis. Ultimately, this may lead to the digital integrated patient record, which should contain the full patient file, including patient history, laboratory reports, images of all modalities, and other information. DICOM covers every detail of medical image handling, for a multitude of imaging modalities and uses, all captured in substandards that are defined by subcommittees and working groups. Therefore, DICOM is a very complicated standard: the full description covers several thousands of pages.[8] A very readable explanation of DICOM for echocardiographers is given by Thomas. [9] Note that the statement that devices are "DICOM compliant" is rather meaningless; DICOM defines a multitude of services and imaging modalities. For each piece of equipment, a DICOM Conformance Statement defines precisely which services are supplied and supported for what modalities and to what extent. For ultrasonography, it is good to know that image loop storage is not a part of the standard US (ultrasound) modality, but of the later defined US-MF (Ultrasound-MultiFrame) modality. To verify interoperability between devices, the conformance statements should be compared—not a simple job for a novice in DICOM.[10] Proprietary Formats
Several manufacturers still use or support their own proprietary formats for storage of digital image runs with associated patient and image information. Such formats include HP-TIFF or DSR,[11] DEFF[12] (both TIFF extensions), and VINGMED. Although these digital formats may be adequate or even have certain advantages in a single-vendor environment, they may complicate exchange with other departments or hospitals, use of PACS, offline analysis systems, and so on. General Purpose Formats
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 4
Other widely used general-purpose image formats are BMP, TIF, GIF, and JPEG. These are often used for export of screen shots or single images for use in reports, presentations, and papers. These formats generally lack the possibility for storage of image loops (movies) and additional patient information. For movies, AVI, MPEG, and QuickTime are popular formats. These are also general-purpose formats without possibilities for storage of associated data. Image Compression For reducing the data storage requirements, image compression can be employed. A distinction should be made between lossless and lossy image compression. For lossless compression techniques (such as Run Length Encoding [RLE], Lossless JPEG, or various general-purpose file compression techniques such as LZW [used in the ubiquitous ZIP or TAR]), reversing the compression will produce a perfect copy of the original image. Unfortunately, lossless compression generally only reduces file sizes by a factor of 2 to 5. Lossy compression can reach much higher compression ratios (up to 20 to 100) at the cost of a certain amount of image degradation, generally by eliminating information for which the eye is least sensitive. This degradation may be very acceptable visually (JPEG factor 20 has been found to produce only diagnostically nonsignificant degradation[13] ), especially when compared with the degradation associated with VCR storage. However, the compression 144
artifacts may certainly influence digital image processing and analysis. Severely lossy compression is not advisable for archiving or when digital image postprocessing is foreseen. Lossy compression techniques include Lossy JPEG, fractal and wavelet compression, and MPEG, a popular compression scheme for movies. DICOM currently supports RLE and JPEG (lossless and lossy) compression. MPEG and JPEG 2000 compression schemes have been proposed as extensions to the standard.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/57.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 7
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Digital Image Processing Digital image processing[14] [15] is a science by itself and cannot be discussed here in great detail. Medical image processing is a thriving subdiscipline with many applications and innovations that have become valuable tools in the hands of the clinician. Several good handbooks on medical image processing, with special attention to ultrasonography, are available.[16] [17] [18] [19]
Image Enhancement: Level Manipulations, Filtering Image enhancement deals with the improvement of images, either for visual interpretation or as a preprocessing for analysis. Most of the techniques described here are available in any general-purpose program for manipulating digital images, such as photo editors, as well as on most ultrasonography machines and offline analysis programs. The simplest class of operations is level manipulations: operations that change the brightness level or color of each pixel without considering any neighboring pixels. These operations are also known as lookup-table (LUT) operations, because the original brightness of the pixel is simply used to look up the new value in a conversion table. Operations of this class include brightness level manipulations and pseudocoloring. Brightness Level Manipulations
This class includes all one-to-one conversions of image brightness levels (input) to display brightness levels (output), either linear or nonlinear. Examples are digital contrast/brightness adjustments, image inversion, gamma correction, and histogram-based conversions. The histogram H(I) of an image is a function that describes, for each brightness level I, the number or percentage of pixels in the image that have this brightness level. Histogram-based conversions include histogram stretching, a linear contrast stretch between the minimum and maximum values of I (or certain
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 7
percentiles) in the histogram; and histogram equalization, a nonlinear transformation that redistributes the gray levels I so that a flat histogram is obtained, increasing the contrast in brightness ranges with many pixels and reducing the contrast in less frequented ranges. Some examples are given in Figure 7-1 . Note that many level manipulations may result in clipping ( See Fig. 7-1C,D , and E ) and in reduction of the effectively used number of brightness levels. The extreme example is thresholding (see Fig. 7-1E) , in which all brightness levels above a threshold are set to white, and all below to black. Pseudocolors
Pseudocoloring involves a direct conversion of brightness levels to a color scale, generally labeled with fancy names such as Rainbow, Ocean, or Harvest. As the eye is more sensitive to color differences than to intensities, this may reveal subtle contrast differences. It can be visually pleasing but it is highly suggestive, as it clusters similar gray values into color groups. Because brightness levels in ultrasonography by themselves do not represent any physical property (see the section on problems and pitfalls) and are highly dependent on gain, signal attenuation, and time gain control, among other factors, the borders that are suggested visually by these colors have no practical significance.[20] This technique is also applied sometimes to highlight brightness values above some threshold with a color, such as during injection of contrast material. Similar objections apply in such a case. Filtering
Filtering is the generic name for image operations that consider neighborhoods of pixels and deal with the spatial or temporal aspects of the image. Filtering operations include noise reduction, smoothing or blurring, and sharpening or edge enhancement. Smoothing or low-pass filtering (e.g., uniform, Gaussian) is used in many ABD methods (see later discussion) to reduce the speckle noise and get more or less homogeneous regions; highpass edge enhancing or detection filters (e.g., Sobel, Laplacian) are often used to find (candidate) border points. Note that most smoothing methods change the positions of edges and cannot differentiate between noise and weak signals. High-pass filters tend to be very sensitive to noise. In general, filtering does not improve the appearance of ultrasonographic images without simultaneously removing valuable information. Smoothing and sharpening filters may be available on your ultrasonography machine for real-time use: keep the above-mentioned caveats in mind when using this
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 7
option. Many more complex forms of postprocessing exist, including median filters, temporal smoothing, morphologic operators such as opening and closing, region growing, matched filters, texture analyses, wavelet transforms, and Fourier and cosine transforms, all of which have been used as parts of ABD methods. Most of these have little practical value by themselves. Image Interpretation: The Interpretation Pyramid The interpretation of highly complex information like medical images is an extremely complicated task. We humans 145
Figure 7-1 Image brightness conversions (look-up table operations) and their results. A, Identity: no change; B, inversion; C, increased contrast (note clipping, C); D, decreased brightness; E, thresholding; F, histogram equalization.
146
Figure 7-2 The image interpretation pyramid.
tend to underestimate it considerably: for us, vision is a very natural process that we perform instantly and automatically. From the study of human perception, we know that vision is anything but a simple, straightforward process. Think of the many well-known optical illusions: there is a lot of hidden interpretation going on. In the interpretation of images, a certain number of information abstraction levels can be distinguished. This is generally known as the image interpretation pyramid (Fig. 7-2) . The levels of this pyramid give us more insight into the mechanisms of different automated techniques and their limitations. A good analogy is found in the interpretation of handwriting or spoken language. This analogy is described in Table 7-1 . For interpretation of a written text, one has to know about the alphabet, spelling, vocabulary,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 7
syntax, and semantics, and ultimately about the subject of the text, the intentions of the source, and adornments such as humor, sarcasm, and metaphors. These last aspects concern real-world knowledge that has nothing to do with language—it refers to the domain that the text is discussing. In practice, this is not just a simple bottom-up TABLE 7-1 -- Abstraction Level Hierarchy Associated Level General Speech Image Cardiac Operations 0 Raw data Samples Pixels Pixels Image generation 1 Features Amplitude, Intensity, Intensity, Preprocessin filtering, frequency texture, texture, feature gradients gradients extraction 2 Structures Phonemes Edges, Edges, Linking, regions regions merging, matching, clustering 3 Objects Words World Cardiac Model entities, structures relaxation, borders, (lumen, border objects endocardium finding, valve) classification 4 Object sets Sentences Scene Cardiac Scene scene modeling, interobject relationships 5 Interpretation Significance Scene Interpretation High-level interpretation and interpretatio diagnosis expert systems, rul process of combining letters into words into sentences into significance. Text can be fragmented; there are imperfections such as misspellings and ambiguities, unknown words, and missing domain knowledge that necessitate interactions and feedback between all levels, and even guessing, to come to a consistent interpretation.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 7
Cardiac Image Interpretation
In image interpretation, we have a similar hierarchy. At the basis, we find the raw image information (pixels). Going up, we encounter image features such as local texture and gradients; structures such as regions (groups of adjacent pixels with similar properties) and edges (lines of sudden change, between regions); objects such as a square or a person; and a scene, such as a football match. At the top we have significance, such as finding out who's winning; this requires very specific knowledge on behavior of the players and audience, rules of the play, and so on.
147
Interpretation of medical images, especially of a complex, dynamic organ like the heart, is still more difficult, as it requires expert knowledge about the three-dimensional anatomic structures in the heart, their dynamic behavior, pathology and anatomic variability between patients, and the intricacies of the imaging modality involved. This last point specifically is not to be underestimated for ultrasonography. Again, interpretation is not a simple bottom-up process. Missing or ambiguous information, disturbances such as noise and artifacts, and higher-level knowledge of anatomy, physiology, and pathology are involved and necessitate feedback and interactions between levels. Clearly, very different sorts of knowledge are applied at each level to come to a valid interpretation, and only the lower levels have to do with image properties: higher levels concern sizes and shapes of cardiac parts, anatomic models of the heart, physiology, congenital or pathologic conditions, and so on. Automated border detection systems generally have very limited knowledge at the higher interpretation levels, and resolve this in one of three ways, as follows: 1. They use simplifying assumptions regarding the objects. For example, the left ventricle is a dark, round object in the middle of the image; the endocardial contour is convex, the endocardium is the strongest edge in the image, the cardiac wall will not move more than x pixels per frame. Most of such assumptions will hold only to some extent or are overly general. 2. They limit themselves to a subset of the problem domain, for aspects like cross sections (e.g., only midpapillary short-axis), image quality
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 7
(no dropouts, low noise), anatomy (e.g., no congenital defects), or imaging equipment or settings (scale, gain, frequency). 3. They require the user to handle the high-level aspects by initializing, steering, or correcting the system. The level of knowledge that a certain system applies, the validity of its assumptions, and the ease of interaction for the user determine the "intelligence" and practical value of the system. Rules for a Well-Behaved Automated Border Detection Method
No practical system can do without the intervention of the user. Ideally, there is only one desired and necessary interaction; in cases in which there is room for multiple interpretations, the user should have the final decision. In practice, a computer system can never have all the high-level knowledge that the physician has, and it requires the physician's intervention to handle these blind spots. Systems with little high-level knowledge and models, however, rely heavily on the user to handle their shortcomings and mistakes (USER = Universal Solution for Error Recovery). With these limitations in mind, we can formulate a few criteria for a good and well-behaved ABD method. 1. The method should generate "correct" contours. Because this judgment may be subjective (in the light of multiple possible interpretations), a system should be able to adapt to the expert user's general ideas about correct contours. 2. The contours should be reproducible; this seems obvious for an automatic system, but almost all systems require some type of user interaction (setting of certain parameters, indicating some start point or region, selection of the images to be analyzed, corrections), which will lead to some variability in results. This inter- and intraobserver difference should possibly be smaller than the considerable inter- and intraobserver variabilities associated with similar manual work. 3. The method should be user-friendly; it should only address the user for high-level expert decisions. It should not require him or her to handle "stupid" mistakes or do repetitive corrections. Some implications are as follows: • It should not generate physically or anatomically impossible solutions; unlikely solutions should be marked as such. It should supply alternative hypotheses (when relevant). • It should not override user-drawn contours, for example, unless
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 7
specifically asked to (apart from clean-up of minor imperfections). • It should allow for easy, intelligent, minimized control and correction (the intent of the correction should be applied throughout the whole image set).
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/58.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 15
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Automated Border Detection in Echocardiography Problems and Pitfalls of Border Detection in Ultrasonography Ultrasonography is a particularly difficult imaging modality for interpretation. Outsiders mostly find it hard to interpret, contrary to other tomographic modalities such as computed tomography and magnetic resonance imaging. Ultrasonography suffers from several specific drawbacks, which also impede automated analysis. 1. There is no simple physical relation between pixel intensity and any physical property of the tissue visualized, in contrast to the LambertBeer law for radiography or the Hounsfield units for computed tomography. In ultrasonography, images are formed by sound reflection and scattering, resulting in a combination of interference patterns (ultrasound speckle patterns) and reflections at tissue transitions. Different tissues are often distinguishable only by subtle differences in texture (speckle patterns) or behavior of texture over time, rather than by different intensity values. 2. Ultrasonographic image information is very anisotropic and positiondependent, as reflection intensity, spatial resolution, and signal-tonoise (S/N) ratio are very dependent on both the depth and the angle of incidence of the ultrasound beam, as well as on the user-controlled time gain compensation (depth gain) settings. Even the definition of the border position may be direction-dependent (leading edge or trailing edge borders[20] ). 148
3. Image disturbances can occur, such as artifacts caused by side lobes, reverberations, lateral and radial point spread functions, and significant amounts of random noise. Many of these problems are associated with high gain settings, which are often necessary in obese or older patients.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 15
Speckle noise can be seen as an artifact as well; although it is an inherent part of ultrasound imaging, it often veils anatomic details. 4. Missing information can occur, such as dropouts (for structures parallel to the ultrasound beam), shadowing (behind acoustically dense structures), scan sector limitations, and limited echo windows. Stillframe images generally miss some information; the human eye compensates for this when viewing a sequence of images. It resolves ambiguities and interpolates the missing parts by exploiting the temporal behavior of structures and texture, which allows discrimination between noise, artifacts, and anatomy. 5. Problems can arise that are caused by the limited temporal resolution and the scanning process. The sequential scanning of lines combines information from different time moments into one image. For quickly moving structures, this may lead to spatial distortion. When the scan frame-rate is not synchronous with the video frame-rate of 25 or 30 images per second, sharp transitions between "old" and "new" scan line information may appear in still images. These effects are stronger for lower scan frame-rates. 6. Two-dimensional ultrasonography generally lacks spatial reference information. No exact spatial localization of the cross-sectional plane is known. In three-dimensional techniques such as magnetic resonance imaging or computed tomography, this information is often employed in model positioning for the detection. In cardiac ultrasonography, the choice of the imaged cross section depends both on the skill and precision of the sonographer and on the available echo window, which is limited by ribs or other structures. Apart from volume measurement errors, this may also result in detection problems if the ABD method relies on assumptions of shape, distance between epicardium and endocardium, and the presence or absence of other structures such as valves or papillary muscles. Practical Considerations for Automated Border Detection Practical considerations for appropriate border detection (either automatic or manual) are listed in Table 7-2 , subdivided into three categories. Acquisition and Image Quality
The primary requirement for any analysis, whether automated, manually traced, or visual, is optimal image quality. If the border cannot be seen, it can only be guessed at (more or less intelligently). Therefore, one should optimize image quality, standardize system settings, and reduce variability
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 15
in settings and cross sections. Select a depth such that the object of interest fits well TABLE 7-2 -- Practical Considerations for Automated Border Detection Acquisition and image quality Optimize border visualization Limit variation in system settings (gain, power, time gain control, lateral gain control) Limit variation in cross sections (use landmarks) Proper region of interest/depth High frame-rate Digital storage (preferably lossless); no filtering No spatial/temporal subsampling or small regions of interest for storage Border definitions and consistency Inventory of desired calculations Standardize border drawing definitions: Inclusion or exclusion of papillary muscles, trabecular structures, valves, etc. Position of edges: leading, peak, trailing Exclusion criteria and special cases: Image quality: foreshortening, dropouts, artifacts, noise Pathologies: hypertrophy, dilation, cardiac masses, etc. Congenital deformations, etc. Assess inter- and intraobserver variabilities: To test standardization To check errors against study goal, estimate patient population size for significance Include acquisition protocol? Choice of detection technique Check specifics of technique against problem: Cross sections Cardiac objects (left ventricle, right ventricle, endocardium, epicardium)
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 15
Border definitions Single frame, ED/ES, full-cycle, multicycle Real-time online or offline with corrections Dependence on image quality, artifacts, settings Amount and types of user interaction Is manual analysis a practical alternative? inside the scan sector and fills most of it. Try to adjust acoustic power, overall gain, time gain control, or lateral gain control such that the endocardium is best and most homogeneously visualized. Remember that stop-frame images are much harder to interpret than moving sequences; individual frames may be much less pleasing than the cineloop suggests. Since most detection methods do not use interframe relationships, they actually use single frames and suffer from the higher uncertainty. A high frame-rate (at least 25 frames per second) is advisable, both for full-cycle analysis or for proper selection of end-diastolic (ED) and end-systolic (ES) frames in case of ED/ES analysis. For image storage, use digital images whenever possible—do not store images on videotape to redigitize later. Avoid lossy compression with high compression rates, image subsampling (resolution reduction), and temporal subsampling (frame rate reduction). When selecting a region of interest for storage, make sure that it will contain the object completely over the full time range. Contour Definitions and Consistency
Before attempting manual or automated detection, make sure that proper criteria are defined for the desired contours. This may depend on the desired calculations to 149
be performed from the contour. Trabecular structures, papillary muscles, or valves can either be included or excluded for certain calculations (LV volume, regional wall motion, LV mass). Many points need to be standardized: whether leading, maximum, or trailing edges are drawn; what to do in case of foreshortening, dropout, and so on.[20] [21] When possible, perform inter- and intraobserver comparisons and try to reach consensus before starting a large study. In some cases, this should include the image acquisition, to assess inter- and intraoperator variability in the choice of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 15
cross section, ultrasonographic system settings, and other factors. Choice of Detection Technique
When considering an automated technique for border detection, it is wise to check the following against the specifications of the automated method: the cross sections involved, the object to be detected (e.g., left ventricle, right ventricle, atrium); single-frame, ED/ES, full-cycle or multicycle analysis; the brand and type of echo machine used; the type of contour to be found (blood-tissue border or other, such as epicardium); online or offline availability of the detection; possibilities for user correction of the boundaries (in offline case); dependency on system gain, image quality, and common artifacts such as dropouts or noise; and amount of user interaction needed. In case no suitable automated technique is found for a certain analysis, manual measurements may (or may not) provide a practical alternative. Overview of Automated Border Detection Methods Ever since the invention of echocardiography, methods have been devised for the automated analysis of these images. Literally hundreds of methods have been reported,[22] [23] most of which have only academic value.[24] [25] We do not try to present a complete taxonomy here and limit ourselves to the main directions of research. We refrain from any comparisons on reported success scores, as there are no standard test data sets for this purpose, nor standard test criteria. It is also difficult to compare the type and extent of user interaction, reproducibility, and so on. Any success scores reported depend very much on the chosen inputs and their quality. Because of lack of a gold standard, contours are generally judged by an expert or compared with contours manually drawn by one or more experts, or derived values such as area or volume are compared with some alternative measurement. Most of these values are hard to compare between studies. A rough measure for the worth of a method could be the number of patients on which it has been tested. Methods that have been tested on fewer than 10 patients probably have no practical value (although their academic value may be high): no matter how naive the method, one can always find a few images on which it will work. A listing of a representative cross section of reported techniques is given in Table 7-3 . For each level, the most basic technique is given first. This one is often applied by methods that focus on other levels. Not surprisingly, older techniques generally operate on a lower level. Of level 5, few true
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 15
examples currently exist. The terms "knowledge-based," "intelligent," and "model-driven" are widely misused, even for the most basic techniques at any level. Feature-Based Method: Integrated Backscatter Method, Advantages, and Limitations
The clinically most widespread method for ABD is by far HewlettPackard's Acoustic Quantification (AQ[26] ), which is installed in several Hewlett-Packard (Philips) ultrasonography machine models (Fig. 7-3) . AQ is not an ABD system in the strict sense as described previously, because it merely does a blood/border/tissue pixel classification (by thresholding) on the basis of the integrated backscatter energy of the radiofrequency ultrasound signal. Therefore, it falls into the lower hierarchical levels of the image interpretation pyramid. However, its use of the radiofrequency data, the online real-time applicability, and widespread availability make it a valuable tool. A real-time lumen area plot and area change (dA/dt) plot can be generated, as well as a real-time frame-to-frame monoplane volume calculation. When used with care in images of good quality, it can give very nice results. However, AQ also suffers from some serious drawbacks, [27] [28] which can be summarized as follows: • The AQ borders are very sensitive to image quality (noise, dropouts) and gain settings (time gain control, lateral gain control), and often difficult to control for the user. Cardiac cycle-dependent intensity changes can influence area change calculations.[27] • AQ uses a fixed, user-drawn region of interest within which the blood pixels are counted. Parts of the ventricle (the valve plane and/or septum) tend to move in and out of such a region throughout the cycle, resulting in considerable measurement errors because of missed parts of the ventricle or included parts of the atrium and the other ventricle. • It is mostly impossible to eliminate tissue parts within the ventricle (valve, papillary muscle, and trabecular structures) or to exclude dropout regions from the ventricle, and noise and artifacts may cause serious problems, especially in difficult patients. Reported success scores in larger patient populations vary widely. • The contours are very noisy, which can be expected for a thresholding-type technique; this implies that they are not directly suitable for regional wall motion calculations. A procedure for extracting and postprocessing these contours has been reported.[29] • The method is real time by nature, as it uses the radiofrequency
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 15
signal, which is available only during image acquisition. Apart from representing a unique advantage, this feature also means that the method cannot be used offline, nor can the same images be reanalyzed with different settings. Whenever radiofrequency data can be stored, this limitation will be resolved. Figure 7-3 (color plate.) Acoustic quantification on Philips (HewlettPackard) equipment. (Courtesy Philips Medical Systems Ultrasound, Andover, Mass.)
150
TABLE 7-3 -- Overview of Automated Border Detection Methods at Different Abstraction Levels Level Name Basic Technique(s) 1. Heavy smoothing for Preprocessing noise/speckle reduction[68] Contrast stretching Histogram equalization
2. Edge or region detection
Advanced Techniques Spatiotemporal smoothing[69]
Morphologic filters[70] Texture filters: inverse difference moment[71] wavelet transforms[72] Fourier-based filters[73] Radiofrequency data processing: integrated backscatter (AQ) [26] Global or local thresholding Advanced edge detectors: [69] [74] Marr-Hildreth[77] [78] Canny[79] [80] [81] rank-based operator[82] Simple edge detectors such Pattern or profile matching[51] as difference-of-boxes[65] [75] [76]
Matched filters[83] arc filters [40]
Region detection: region growing[73] fuzzy clustering;
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 15
resolution pyramids; neural nets; Markov random fields [84]
3. Geometric Implicit models: e.g., radial objects or search for candidate points, [68] models interpolation/linking, smoothing/shape filtering
Classification of edge points by fuzzy reasoning[78]
Dynamic Programming optimization[42] [80] [85] [86] [87] Simulated annealing[81] selforganizing maps (SOM, Kohonen)[82] Snakes/balloons/active contours/deformable contours, etc.[75] [79] [80] , [88] Active shape models (ASM) [51] [52]
4. Anatomic None or implicit: Hardstructure or coded scene models Manually positioned
User-drawn
Single geometrical shape models—2D, 2D + T, 3D, 3D + T: Model positioning/landmark finding techniques: row/column sums,[76] [78] arc filters,[40] template matching; Hough transform [81] fuzzy logic[72] Shape parameters (2D + [23] T) 3D shape neural nets[89] Composite models (several objects and their relation, e.g., ventricles and septum)—2D, 2D + T, 3D, 3D + T: Point distribution models [53]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 15
Multiple active contours[79] Fuzzy neural nets (2D)[90] Adaptation of models to image and user[23]
5. None Interpretation, high-level knowledge User intervention: correction Use of patient group derived of contours, etc models: neural nets,[70] SOM, [82] geometrical eigenvariations (PDM)[51] [53] Learning behavior over all cases analyzed Rule-based analysis Pathology awareness Multiple hypothesis generation 2D, two-dimensional; 3D, three-dimensional; PDM, Point Distribution Models; T, time.
Most of these problems are exemplary for a low-level method that does not use any geometric models or knowledge about cardiac anatomy. Apart from these drawbacks, the use of radiofrequency data supplies superior basic information for blood-tissue classification and may well serve as a basis for higher-level developments, especially when the digital radiofrequency data become available for offline postprocessing. The use of harmonic imaging (see later discussion) has been shown to improve AQ border delineation[30] [31] but does not eliminate most of these problems. A spin-off of AQ is known as color kinesis[32] [33] (Fig. 7-4) . This technique is in essence a method of presenting the time sequence of AQ contours in a single image, by color-coding the lumen area for each time frame and superimposing the images. This method renders a rainbow-like lumen in which each color represents some time-offset from ED. Provided there is little global heart translation, this can give a good impression of wall motion patterns in systole or diastole, especially when these motions are analyzed per region.[33] [34] [35] Of course, all limitations of AQ apply here as
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 15
well, plus the concern of overall heart translation, making this technique also challenging to apply accurately.
151
Figure 7-4 (color plate.) Color kinesis image on Philips (HewlettPackard) equipment. (Courtesy Philips Medical Systems Ultrasound, Andover, Mass.) Clinical Use
Acoustic Quantification has been applied in clinical studies for many purposes, especially for looking at left ventricular function (lumen area, volume, and fractional area change). Studies on right ventricular function have been reported as well.[36] Combination of AQ data with invasively measured ventricular pressure has been reported,[37] allowing pressure-area and pressure-volume loops to be constructed, which may hold promise for the assessment of LV mechanical performance. Color kinesis has been used for studying wall motion patterns in several patient groups, systolic and diastolic function, regional wall motion in stress echo, and other parameters.[35] [38] [39] Structure-Based Method: Matched Filters As an example of a structure-based method, we highlight the method by Geiser and Wilson and their group[24] , [40] [41] for automatically detecting endocardial and epicardial borders in short-axis echocardiograms. The method is based on matched filters that respond to arclike structures. The first step applies a filter that responds to the bright epicardial-pericardial interface at the posterior wall. Subsequently, other circular structures along the wall are detected and, after update of the LV center estimate, redetected (an example of high-to-low level feedback). This gives an estimate of epicardial position, which is used as a region of interest. Radial edge detectors are used to locally adjust epicardial edges and to estimate the (relatively strong) anteroseptal endocardial edge. From the estimated wall thickness, the border search is further limited and final endocardial and epicardial edge estimates are found (Fig. 7-5) . This method seems practically useful (it has been validated on a large set of quality-selected patients), and it is clever in the sense that it uses feedback
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 15
between a high-level model of a short-axis cross section and low-level feature data. From a theoretical viewpoint, it is vulnerable because of the cascade of dependent steps, each of which may fail and cause the process to break down. Much of the applied geometrical and expert knowledge (such as the order of strength of expected features) seems to be coded into the steps of the algorithm rather than being captured in a general model. Such an approach may be hard to extend to other views or to certain pathologic conditions that break the assumptions, as this requires redesigning the algorithm. Object-Based Method: Echo-CMS Method
As an example of an object-based (pattern- and geometric model based) ABD method, we describe the Echo-CMS system (MEDIS Medical Imaging Systems, Leiden, The Netherlands) that was developed in our laboratory. The system has been designed for practical use, with the main intent of quantifying endocardial wall motion and lumen volume frame-toframe. A relatively simple circular model-based Dynamic Programming approach is used for short-axis views.[28] [42] An LV center point is indicated by the user, defining a circular model and region of interest in which the strong endocardial edge is found by Dynamic Programming using first derivatives and smoothness and distance constraints. The found border is used as a model in neighboring frames to allow frame-to-frame analysis. In the different long-axis views (apical four-chamber, two-chamber, and parasternal long axis), a more elaborate semiautomated pattern-based approach is used.[23] [43] For the analysis of one or more complete beats (Fig. 7-6A) , one ED and ES contour must be manually drawn (Fig. 7-6B) . Next, three landmark points characterizing the position of the LV (apex and mitral valve attachment points, which are the end points of the contour) are extracted from the contours and interpolated or extrapolated linearly over the cycles. The user is required to inspect these markers over the cycles and may then redefine, if necessary, intermediate positions where the true position deviates from the estimated position. Now, the automated contour detection is started. From the manually drawn ED and ES contours, models are extracted describing the geometrical shape of the ventricle over the cycle and the intensity profiles in a neighborhood of the drawn contours. All models (phase, pose, geometry, and edge profiles) are interpolated over the cycle and extrapolated over other cycles ( see Fig. 7-6C, D andE ). The resulting geometry models are positioned over the images ( Fig. 7-7A and B ), which are resampled along straight lines perpendicular to the models.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 15
For each point of all scan lines (see Fig. 7-7C, left) , a cost value is calculated representing the likelihood of this point as a contour point: unlikely points will have high costs. The cost is calculated from a combination of edge detectors, match differences with the edge profile models, and local edge reliability measures. Through this rectangular array of cost values (see Fig. 7-7C, center) , an optimal connective path is determined using a Dynamic Programming approach. Cumulative costs for all connective paths are calculated, applying position-dependent penalties for deviation from a straight path. In this way, local stiffness of 152
Figure 7-5 (color plate.) Short-axis border detection with arc filters. Top, Short-axis echocardiographic images at end-diastole and endsystole. Bottom, automatically generated borders at end-diastole and end-systole. (From Sheehan F, Wilson DC, Shavelle D, Geiser EA: Echocardiography. In Sonka M, Fitzpatrick JM (eds): Handbook of Medical Imaging, vol 2. Medical Image Processing and Analysis. Bellingham, Wash, SPIE—The International Society for Optical Engineering, 2000, p 609.)
parts of the border is modeled. The path with overall lowest cost is selected as optimal (see Fig. 7-7C, right) and by inversion of the resampling process converted into a new contour (see Fig. 7-7D) . After detection of all contours (see Fig. 7-6F) , the user may apply any corrections by overdrawing part of a contour. Consecutively, all models are updated with the extra user-defined information, which is interpolated and extrapolated over the sequence, followed by a redetection of all non-manual contours. In short, this method uses full-cycle models for the two-dimensional pose, shape, and local stiffness properties of the wall and for the intensity profiles of the edges. Case-specific and user-specific information is incorporated by collecting information from all user-defined contours. Drawbacks are the need for two manually defined borders and the marker manipulations. Clinical Use
This method has been applied in studies on wall motion patterns for pacemakers[44] [45] and systolic function.[46] [47] [48] The system has some very strong features, including tracking of structures other than blood-tissue borders (user-defined positions); temporal and spatial coherence; and basic
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 15
knowledge of LV anatomy and appearance. For research purposes, it has been shown to be a valuable tool, but at the moment it is mainly focused on frame-to-frame or multibeat analyses of wall motion patterns. For ED/ES analyses, it offers no extra benefits, as the ED/ES contours need to be defined manually. Population Model-Based Method: Active Appearance Models Great promise is held by a new class of techniques called Active Appearance Models (AAMs). These techniques were originally developed by Cootes and coworkers[49] [50] for facial recognition and medical image analysis, as an extension of the active shape model (ASM[51] [52] [53] ) approach. We have recently applied AAMs to magnetic resonance imaging [54] and echocardiography [55] with very promising results. These techniques derive the typical shape and appearance of an echocardiogram from a large 153
Figure 7-6 Echo-CMS semiautomated border detection procedure. A, Electrocardiogram (ECG) and original images; B, manual drawing of two contours and inspection of markers; C, generation of pose models (landmarks); D, generation of shape models; E, generation of profile models (match patterns); F, automatically detected contours. Figure 7-7 Echo-CMS dynamic programming border detection. A, Original image; B, image with landmarks and shape model; C, scan value matrix (left), cost value matrix (middle), and detected path (right); D, image with detected contour.
154
Figure 7-8 Active appearance model: average four-chamber images of left ventricle from 65 patients, at different moments in the cardiac phase. A, End-diastole; B, mid-systole; C, end-systole; D, end of rapid filling; E, start of atrial filling.
set of example images with expert-drawn contours. Principal Component Analysis (PCA) on a point distribution model extracts the average organ shape and the principal variations (so called eigenvariations) of shape. By
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 15
warping all examples to the average shape, an average image (Fig. 7-8) and principal image variations (Fig. 7-9) can be found. By applying another PCA, simultaneous shape and intensity, eigenvariations are modeled in an Appearance Model. Such an appearance model can synthetically generate "probable" echocardiographic images similar to the variations shown in Figure 7-9 . By deforming the model Figure 7-9 (color plate.) Active appearance model eigenvariations: Top to bottom: eigenvariations 1 to 4 of four-chamber left ventricle at end-diastole. Left to right: average minus 3 standard deviations, average, average plus 3 standard deviations. Note the simultaneous shape and intensity variations.
along the characteristic model eigenvariations, using a gradient descent minimization of the difference between the synthetic and the real image, the desired structure can be found (Fig. 7-10) . This can be done fast and fully automatically with good results. This technique has some significant advantages: it models both average organ shape and all variations over a population of examples; it models the complete organ Figure 7-10 Active appearance model matching results on end-systolic left ventricular four-chamber image. A, Image with initial model; B, intermediate iteration; C, final matching result.
155
appearance, including typical artifacts; it captures the expert's definition of proper border definition; it can model complex shapes (e.g., LV endocardium plus LV epicardium, right ventricle, valves); it is not limited to blood-tissue borders; and it is easily customizable for different types of images. Limitations of this technique are its dependence on the training data, the selected population of examples, and the quality of the expert contours.
MD Consult L.L.C. http://www.mdconsult.com
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 4
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Future Promise In the near future, serious improvements in the applicability of ABD can be expected. Some instrumental developments will have important effects, and the ABD methods themselves will improve. Impact of Instrumental Developments Harmonic Imaging
Any technical measure that improves visual image quality is likely to improve ABD as well. This is certainly true for harmonic imaging. Originally intended to be used in combination with contrast, harmonic imaging has been shown to improve endocardial visualization in twodimensional echocardiography[56] without contrast as well.[30] It has also been shown to improve endocardial tracking by AQ as rated visually,[30] and by correlating AQ EF measurements to x-ray ventriculography.[31] AQ with harmonic imaging still underestimates absolute volumes and can be technically difficult to perform. Note that harmonic imaging will not improve image quality in all cases, and that it sometimes results in a very grainy image. ABD techniques that rely on image texture may be influenced, but others should certainly benefit from harmonic imaging. Tissue Doppler, Strain Imaging
Tissue Doppler imaging can supply real-time information on tissue velocity in the direction of the ultrasound beam, and thus in itself is a method for quantification of motion.[57] [58] [59] [60] The derived strain rate imaging[61] and strain imaging [62] [63] techniques provide an estimate of local tissue strain, but their practical value remains to be established. For certain purposes, this may become an alternative to border motion detection approaches, but the one-dimensionality of the measurement limits its use considerably. Tissue Doppler information could also well be included in ABD techniques, as it provides clues both on presence and local speed of tissue. ABD might
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 4
supply additional (transversal) motion information. Three-Dimensional and Four-Dimensional Ultrasonography
In principle, three-dimensional image acquisition may provide superior input data for ABD. Border positions can be detected more reliably if information from neighboring slices can be used: spatial continuity, like temporal continuity, may provide additional clues in difficult-to-interpret cases. Furthermore, real volumes can be calculated from three-dimensional data instead of monoplane or biplane estimates. However, the triggered acquisition of such image sets may introduce motion artifacts. Threedimensional smoothing and cut-plane interpolations may also influence border positions. This modality will probably benefit most from an inherently three-dimensional or four-dimensional model-based detection technique. Momentarily, real-time three-dimensional ultrasonography (Volumetrics, Durham, NC) is becoming available[64] [65] this eliminates triggering problems and motion artifacts, but image quality is still limited. With improvement of image quality, real-time 3D echocardiography may become an important substrate for ABD. Contrast
Ultrasonographic contrast agents can be used for luminal opacification to improve visualization of the endocardial border, or for myocardial opacification. Contrary to what is sometimes suggested,[66] it is unlikely that contrast will directly enhance ABD. Although lumen opacification may boost the visual interpretation, application of contrast still has many pitfalls. The transient nature of the opacification, incomplete or inhomogeneous filling of the cavity, shadowing, and local destruction of microbubbles (causing mixing of "white" and "black" blood), especially, make it hard to model the lumen appearance for any detection method. Next-generation contrast agents or special-purpose border detection techniques may provide solutions. Digital Image Storage and Radiofrequency Data
Digital image storage and communication will have a positive effect on general image quality and the availability of additional information (calibration, time, patient age and sex, body surface area, physiologic signals, protocol stages, views) can be a highly important source of a priori information for ABD techniques. As soon as raw radiofrequency information becomes available via digital storage, digital postprocessing of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 4
these data may provide superior input for ABD methods, effectively combining the strengths of AQ with those of high-level model-based approaches. Developments in Image Processing Model-Based Techniques
As seen in the section on Active Appearance Models, the biggest promises come from new developments in higher-level image processing. These techniques can model the complete appearance of a cardiac echo scene, 156
including patient variabilities. This approach may allow more natural solutions than older, edge-based or geometric model-based approaches. Because both shape variations over a large patient set and image appearance variations can be modeled, these techniques may handle typical artifacts, locally differing edge patterns, and other problems while restricting themselves to probable shapes. Furthermore, it seems possible to separate these models in patient-specific, view-specific, and pathologyspecific parts,[67] allowing more precise and flexible models and opening views to automated classification. The next-generation ABD technique for ultrasonography may well emerge from this family. Intelligent Systems
At the interpretation level, we enter the domain of artificial intelligence. Work in this field, especially in conjunction with image interpretation, is still in its infancy. Many high-level interpretation problems will need techniques from the field of artificial intelligence to be solved: formal reasoning from rule-based expert knowledge; generating multiple hypotheses with measures of confidence; reasoning with pathologic or congenital conditions during detection; checking overall consistency of an interpretation and taking action to resolve conflicts; opportunistically choosing an optimal detection strategy for the image data presented; and learning from operator corrections and actions. Ultimately, such developments may lead to an intelligent "automated image interpretation assistant" for echocardiographers.
MD Consult L.L.C. http://www.mdconsult.com
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Summary Automated border detection for ultrasonography is still undergoing development. Few clinically applicable systems exist, and automation is limited. Positive expectations exist for the future. On the instrumental side, new opportunities will emerge from computer and ultrasonographic hardware improvements, availability of digital images and of raw radiofrequency information, and the perfection of techniques such as harmonic imaging, tissue Doppler imaging, real-time three-dimensional echocardiography, and maybe contrast echocardiography. In the field of ABD, improvements will result from several new technologies at the higher hierarchical levels (especially better three- and four-dimensional geometric modeling, anatomic scene descriptions, and modeling of anatomic interpatient variability and pathologic conditions) and techniques from artificial intelligence.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/61.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 9
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
References 1. Foster E, Cahalan MK: The search for intelligent quantitation in echocardiography:
"Eyeball," "trackball" and beyond. J Am Coll Cardiol 1993;22:848. 2. Hoffman R, Lethen H, Marwick TH, et al: Analysis of interinstitutional observer
agreement in interpretation of dobutamine stress echocardiograms. J Am Coll Cardiol 1996;27:330. 3. Feigenbaum H: Instrumentation. In Echocardiography. Philadelphia, Lea & Febiger,
1986, p 1. 4. Geiser EA: Echocardiography: Physics and instrumentation. In Skorton DJ,
Schelbert HR, Wolf GL, Brundage BH (eds): Marcus Cardiac Imaging: A Companion to Braunwald's Heart Disease. Philadelphia, WB Saunders, 1996, p 273. 5. Weyman AE: Physical principles of ultrasound. In Weyman AE (ed): Principles and
Practice of Echocardiography. Philadelphia, Lea & Febiger, 1994, p 3. 6. Weyman AE: Cross-sectional scanning: Technical principles and instrumentation. In
Weyman AE (ed): Principles and Practice of Echocardiography. Philadelphia, Lea & Febiger, 1994, p 29. 7. Kennedy TE, Nissen SE, Simon R, et al: Digital Cardiac Imaging in the 21st
Century: A Primer. Bethesda, Md, American College of Cardiology, Cardiac and Vascular Information Working Group, 1997. 8. DICOM Committee: Digital Imaging and Communications in Medicine (DICOM),
1999 ed. Rosslyn, Va, National Electrical Manufacturers Association, 1999. 9. Thomas JD: The DICOM image formatting standard: What it means for
echocardiographers. J Am Soc Echocardiogr 1995;8:319.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 9
10. Waitz AS: An echocardiographer's guide to determining whether DICOM disk
interchange can be achieved between two systems. In Kennedy TE, Nissen SE, Simon R, et al (eds): Digital Cardiac Imaging in the 21st Century: A Primer. Bethesda, Md, American College of Cardiology, Cardiac and Vascular Information Working Group, 1997, p 138. 11. Anonymous: Digital Storage and Retrieval (DSR) File Format Specification V 0.18
(Report Nr. 77450-99000). Andover, Mass, Agilent Technologies, Healthcare Solutions Group, Imaging Systems Division (ISY), 2000. 12. Bono J: Data Exchange File Format (Report Nr. 9062-0085-00 rev B). Bothell,
Wash, ATL Ultrasound, 1992. 13. Karson TH, Chandra S, Morehead AJ, et al.: JPEG compression of digital
echocardiographic images: Impact on image quality. J Am Soc Echocardiogr 1995;8:306. 14. Castleman KR: Digital image processing. Englewood Cliffs, NJ, Prentice-Hall,
1996. 15. Sonka M, Hlavac V, Boyle R: Image Processing, Analysis and Machine Vision,
2nd ed. Pacific Grove, Calif, International Thomson-Brooks/Cole, 1999. 16. Collins SM, Skorton DJ: Cardiac Imaging and Image Processing. New York,
McGraw-Hill, 1986. 17. Skorton DJ, Schelbert HR, Wolf GL, Brundage BH: Marcus Cardiac Imaging: A
Companion to Braunwald's Heart Disease, 2nd ed. Philadelphia, WB Saunders, 1996. 18. Sonka M, Fitzpatrick JM: Handbook of Medical Imaging, vol 2. Medical Image
Processing and Analysis. Bellingham, Wash, SPIE—The International Society for Optical Engineering, 2000. 19. Thomas JD: Digital image processing. In Weyman AE (ed): Principles and Practice
of Echocardiography. Philadelphia, Lea & Febiger, 1994, p 56. 20. Vuille C, Weyman AE: Left ventricle I: General considerations, assessment of
chamber size and function. In Weyman AE (ed): Principles and Practice of Echocardiography. Philadelphia, Lea & Febiger, 1994, p 575. 21. Nidorf SM, Weyman AE: Left ventricle II: quantification of segmental
dysfunction. In Weyman AE (ed): Principles and Practice of Echocardiography.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 9
Philadelphia, Lea & Febiger, 1994. 22. Sher DB, Revankar S, Rosenthal S: Computer methods in quantitation of cardiac
wall parameters from two dimensional echocardiograms: A survey. Int J Card Imaging 1992;8:11. 23. Bosch JG, van Burken G, Nijland F, Reiber JHC: Overview of automated quantitation techniques in 2D echocardiography. In Reiber JHC, van der Wall EE (eds): What's New in Cardiovascular Imaging. Dordrecht, The Netherlands, Kluwer, 1998, p 363. 24. Sheehan F, Wilson DC, Shavelle D, Geiser EA: Echocardiography. In Sonka M,
Fitzpatrick JM (eds): Handbook of Medical Imaging, vol 2. Medical Image Processing and Analysis. Bellingham, WA, SPIE—The International Society for Optical Engineering, 2000, p 609. 25. Geiser EA: Edge detection and wall motion analysis. In Chambers J, Monaghan M
(eds): Echocardiography: An international review. Oxford, Oxford University Press, 1993, p 71. 157
26. Perez JE, Waggoner AD, Barzilai B, et al: On-line assessment of ventricular
function by automatic boundary detection and ultrasonic backscatter imaging. J Am Coll Cardiol 1992;19:313. 27. Marcus R, Bednarz J, Coulden R, et al: Ultrasonic backscatter system for
automated on-line endocardial boundary detection: Evaluation by ultrafast computed tomography. J Am Coll Cardiol 1993;22:839. 28. Bosch JG, Reiber JH, van Burken G, et al: Automated contour detection and
acoustic quantification. Eur Heart J 1995;16 (Suppl J):35. 29. Chandra S, Garcia MJ, Morehead AJ, et al: Spatiotemporal Fourier filtration of
acoustic quantification endocardial border using carthesian vs. polar coordinate system. In Proceedings, Computers in Cardiology. Los Alamitos, Calif, IEEE Computer Society Press, 1994, p 17. 30. Spencer KT, Bednarz J, Rafter PG, et al: Use of harmonic imaging without echocardiographic contrast to improve two-dimensional image quality. Am J Cardiol 1998;82:794.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 9
31. Tsujita-Kuroda Y, Zhang G, Sumita Y, et al: Validity and reproducibility of echocardiographic measurement of left ventricular ejection fraction by Acoustic Quantification with Tissue Harmonic Imaging technique. J Am Soc Echocardiogr 2000;13:300. 32. Lang RM, Vignon P, Weinert L, et al: Echocardiographic quantification of regional
left ventricular wall motion with color kinesis. Circulation 1996;93:1877. 33. Mor-Avi V, Vignon P, Koch R, et al: Segmental analysis of color kinesis images:
New method for quantification of the magnitude and timing of endocardial motion during left ventricular systole and diastole. Circulation 1997;95:2082. 34. Vignon P, MorAvi V, Weinert L, et al: Quantitative evaluation of global and
regional left ventricular diastolic function with color kinesis. Circulation 1998;97:1053. 35. Koch R, Lang RM, Garcia MJ, et al: Objective evaluation of regional left
ventricular wall motion during dobutamine stress echocardiographic studies using segmental analysis of color kinesis images. J Am Coll Cardiol 1999;34:409. 36. Helbing WA, Bosch HG, Maliepaard C, et al: On-line automated border detection
for echocardiographic quantification of right ventricular size and function in children. Pediatr Cardiol 1997;18:261. 37. Gorcsan J, Romand JA, Mandarino WA, et al: Assessment of left ventricular
performance by on-line pressure-area relations using echocardiographic automated border detection. J Am Coll Cardiol 1994;23:242. 38. Carey CF, Mor-Avi V, Koch R, et al: Effects of inotropic stimulation on segmental
left ventricular relaxation quantified by color kinesis. Am J Cardiol 2000;85:1476. 39. Mor-Avi V, Spencer KT, Lang RM: Acoustic quantification today and its future
horizons. Echocardiography 1999;16:85. 40. Geiser EA, Wilson DC, Wang DX, et al: Autonomous epicardial and endocardial
boundary detection in echocardiographic short-axis images. J Am Soc Echocardiogr 1998;11:338. 41. Geiser EA, Wilson DC: Automatic center point determination in 2-dimensional
short-axis echocardiographic images. Pattern Recognition 1992;25:893. 42. Bosch JG, Savalle LH, van Burken G, Reiber JHC: Evaluation of a semiautomatic
contour detection approach in sequences of short-axis two-dimensional
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 9
echocardiographic images. J Am Soc Echocardiogr 1995;8:810. 43. Bosch JG, van Burken G, Reiber JHC: Automatic frame-to-frame contour
detection in echocardiograms using motion estimation. In Proceedings, Computers in Cardiology. Los Alamitos, Calif, IEEE Computer Society Press, 1992, p 351. 44. Auricchio A, Ghanem A, Groethus F, et al: Echocardiographic analysis of left ventricular contraction patterns in left bundle branch block and congestive heart failure [abstract]. J Cardiac Failure 1999;5(Suppl 1):3. 45. Breithardt OA, Kramer A, Schiffgens B, et al: Characteristics of left ventricular
contraction patterns and acute changes with multisite pacing in patients with heart failure as assessed by echocardiographic semiautomatic contour detection [abstract]. Eur Heart J 2000;21:351. 46. Fry SJ, Hunziker PR, Bosch HG, et al: Automated echocardiographic confirmation
of regional wall motion abnormalities: Quantitation of continuous LV volume [abstract]. J Am Coll Cardiol 1998;31:56A. 47. Hunziker PR, Schöb L, Lefkovits M, et al: Automatic border detection in
dobutamine stress echo: How do normal and ischaemic segments behave objectively and quantitatively? [abstract]. Eur Heart J 1999;20:618. 48. Hunziker PR, Yuan D, Schöb L, et al: Objective and quantitative stress echo
analysis to diagnose coronary disease using model-based image processing [abstract]. J Am Coll Cardiol 2000;35:413A. 49. Cootes TF, Edwards GJ, Taylor CJ: Active Appearance Models. In Proceedings,
European Conference Computer Vision. Berlin, Springer, 1998;2:484. 50. Edwards GJ, Taylor CJ, Cootes TF: Interpreting face images using Active
Appearance Models. In Proceedings of the 3rd International Conference on Face and Gesture Recognition. Nara, Japan, IEEE Computer Society Press, 1998, p 300. 51. Cootes TF, Hill A, Taylor CJ, Haslam J: Use of active shape models for locating
structures in medical images. Image Vision Computing 1994;12:355. 52. Cootes TF, Taylor CJ, Cooper DH, Graham J: Active shape models: Their training
and application. Comp Vision Image Understanding 1995;61:38. 53. Parker AD, Hill A, Taylor CJ, et al: Application of point distribution models to the
automated analysis of echocardiograms. In Proceedings, Computers in Cardiology. Los Alamitos, Calif, IEEE Computer Society Press, 1994, p 25.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 9
54. Mitchell SC, Lelieveldt BPF, van der Geest RJ, et al: Segmentation of cardiac MR images: An active appearance model approach. In Proceedings, SPIE Medical Imaging 2000, Image Processing. Bellingham, Wash, SPIE—The International Optical Engineering Society, 2000;3979:224. 55. Bosch JG, Mitchell SC, Lelieveldt BPF, et al: Feasibility of fully automated border
detection on stress echocardiograms by Active Appearance Models [abstract]. Eur Heart J 2000;21:11. 56. van Camp G, Franken PR, Schoors D, et al: Impact of second harmonic imaging on
the determination of the global and regional left ventricular function by 2D echocardiography: A comparison with MIBI gated SPECT. Eur J Echocardiogr 2000;1:122. 57. Isaaz K: What are we actually measuring by Doppler tissue imaging? J Am Coll
Cardiol 2000;36:897. 58. Hunziker PR, Picard MH, Jander N, et al: Regional wall motion assessment in
stress echocardiography by tissue Doppler bull's-eyes. J Am Soc Echocardiogr 1999;12:196. 59. Derumeaux G, Ovize M, Loufoua J, et al: Assessment of nonuniformity of transmural myocardial velocities by color-coded tissue Doppler imaging: Characterization of normal, ischemic, and stunned myocardium. Circulation 2000;101:1390. 60. Pasquet A, Armstrong G, Beachler L, et al: Use of segmental tissue Doppler
velocity to quantitate exercise echocardiography. J Am Soc Echocardiogr 1999;12:901. 61. Heimdal A, Stoylen A, Torp H, Skjaerpe T: Real-time strain rate imaging of the
left ventricle by ultrasound. J Am Soc Echocardiogr 1998;11:1013. 62. Armstrong G, Pasquet A, Fukamachi K, et al: Use of peak systolic strain as an
index of regional left ventricular function: Comparison with tissue Doppler velocity during dobutamine stress and myocardial ischemia. J Am Soc Echocardiogr 2000;13:731. 63. Urheim S, Edvardsen T, Torp H, et al: Myocardial strain by Doppler
echocardiography: Validation of a new method to quantify regional myocardial function. Circulation 2000;102:1158. 64. Qin JJX, Jones M, Shiota T, et al: New digital measurement methods for left
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 9
ventricular volume using real-time three-dimensional echocardiography: Comparison with electromagnetic flow method and magnetic resonance imaging. Eur J Echocardiogr 2000;1:96. 65. Takuma S, Zwas DR, Fard A, et al: Real-time, 3-dimensional echocardiography
acquires all standard 2-dimensional images from 2 volume sets: A clinical demonstration in 45 patients. J Am Soc Echocardiogr 1999;12:1. 66. Kamp O, Sieswerda GT, Visser CA: State-of-the-art: Stress echocardiography
entering the next millennium. In Reiber JHC, van der Wall EE (eds): What's new in cardiovascular imaging. Dordrecht, The Netherlands, Kluwer, 1998, p 351. 67. Costen N, Cootes TF, Edwards GJ, Taylor CJ: Simultaneous extraction of
functional face subspaces. In Proceedings, IEEE Computer Vision & Pattern Recognition. Los Alamitos, Calif, IEEE Computer Society Press, 1999, p 492. 158
68. Grube E, Mathers F, Backs B, Luederitz B: Automatische und halbautomatische
Konturfindung des linken Ventrikels im zweidimensionalen Echokardiogramm: Invitro Untersuchungen an formalinfixierten Schweineherzen. Z Kardiol 1985;74:15. 69. Ezekiel A, Garcia EV, Areeda JS, Corday SR: Automatic and intelligent left
ventricular contour detection from two-dimensional echocardiograms. In Proceedings, Computers in Cardiology. Los Alamitos, Calif, IEEE Computer Society Press, 1985, p 261. 70. Klingler JW, Vaughan CL, Fraker TD, Andrews LT: Segmentation of
echocardiographic images using mathematical morphology. IEEE Trans Biomed Eng 1988;35:925. 71. Montilla G, Barrios V, Roux C, et al: Border detection in echocardiography images
using texture analysis. In Proceedings, Computers in Cardiology. Los Alamitos, Calif, IEEE Computer Society Press, 1992, p 643. 72. Setarehdan SK, Soraghan JJ: Automatic left ventricular feature extraction and
visualisation from echocardiographic images. In Proceedings, Computers in Cardiology. Los Alamitos, Calif, IEEE Computer Society Press, 1996, p 9. 73. Verlande M, Flachskampf FA, Schneider W, et al: 3D reconstruction of the beating
left ventricle and mitral valve based on multiplanar TEE. In Proceedings, Computers
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 9
in Cardiology. Los Alamitos, Calif, IEEE Computer Society Press, 1991, p 285. 74. Han CY, Lin KW, Wee WG, et al: Knowledge-based image analysis for automated
boundary extraction of transesophageal echocardiographic left-ventricular images. IEEE Trans Med Imaging 1991;10:602. 75. Hozumi T, Yoshida K, Yoshioka H, et al: Echocardiographic estimation of left ventricular cavity area with a newly developed automated contour tracking method. J Am Soc Echocardiogr 1997;10:822. 76. Monteiro AP, Marques de Sa JP, Abreu-Lima C: Automatic detection of
echocardiographic LV-contours: A new image enhancement and sequential tracking method. In Proceedings, Computers in Cardiology. Los Alamitos, Calif, IEEE Computer Society Press, 1988, p 453. 77. Chu CH, Delp EJ, Buda AJ: Detecting left ventricular endocardial and epicardial
boundaries by digital two-dimensional echocardiography. IEEE Trans Med Imaging 1988;7:81. 78. Feng J, Lin W-C, Chen C-T: Epicardial boundary detection using fuzzy reasoning.
IEEE Trans Med Imaging 1991;10:187. 79. Chalana V, Linker DT, Haynor DR, Kim Y: A multiple active contour model for
cardiac boundary detection on echocardiographic sequences. IEEE Trans Med Imaging 1996;15:290. 80. Dong L, Pelle G, Brun P, Unser M: Model-based boundary detection in
echocardiography using dynamic programming technique. In Proceedings, SPIE Medical Imaging V. Bellingham, Wash, SPIE-The International Society for Optical Engineering, 1991, p 178. 81. Friedland N, Adam D: Echocardiographic myocardial edge detection using an
optimization protocol. In Proceedings, Computers in Cardiology. Los Alamitos, Calif, IEEE Computer Society Press, 1989, p 379. 82. Belohlavek M, Manduca A, Behrenbeck T, et al: Image analysis using modified
self-organizing maps: Automated delineation of the left ventricular cavity in serial echocardiograms. In Proceedings of the 4th International Conference on Visualisation in Biomedical Computing, VBC '96. Berlin, Springer, 1996, p 247. 83. Detmer PR, Bashein G, Martin RW: Matched filter identification of left-ventricular
endocardial borders in transesophageal echocardiograms. IEEE Trans Med Imaging 1990;9:396.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 9
84. Herlin IL, Nguyen C, Graffigne C: Stochastic segmentation of ultrasound images.
In Proceedings of the 11th IAPR International Conference on Pattern Recognition A: Computer Vision and Applications. Los Alamitos, Calif, IEEE Computer Society Press, 1992, p 289. 85. Dias JMB, Leitao JMN: Wall position and thickness estimation from sequences of
echocardiographic images. IEEE Trans Med Imaging 1996;15:25. 86. Gustavsson T, Molander S, Pascher R, et al: A model-based procedure for fully
automated boundary detection and 3D reconstruction from 2D echocardiograms. In Proceedings, Computers in Cardiology. Los Alamitos, Calif, IEEE Computer Society Press, 1994, p 209. 87. Maes L, Delaere D, Suetens P, et al: Automated contour detection of the left
ventricle in short axis view and long axis view on 2D echocardiograms. In Proceedings, Computers in Cardiology. Los Alamitos, Calif, IEEE Computer Society Press, 1990, p 603. 88. Cohen LD: Note on active contour models and balloons. CVGIP Image
Understanding 1991;53:211. 89. Coppini G, Poli R, Valli G: Recovery of the 3-D shape of the left ventricle from
echocardiographic images. IEEE Trans Med Imaging 1995;14:301. 90. Brotherton T, Pollard T, Simpson P, DeMaria A: Echocardiogram structure and
tissue classification using hierarchical fuzzy neural networks. In Proceedings, IEEE Conference on Acoustics, Speech, and Signal Processing. IEEE New York, Computer Society Press, 1994, p 573.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/62.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
159
Chapter 8 - Myocardial Contrast Echocardiography Methods, Analysis, and Applications Thomas R. Porter MD Danielle Noll MD Feng Xie MD
Background The use of hand-agitated saline as a source of ultrasonographic contrast was first described in 1968, based on the concept of creating a gas-blood interface for ultrasonic enhancement of blood within the heart. During the following years, bubbles from agitated saline as well as a variety of other substances were used as echocardiographic contrast agents. Because of the large size of the microbubbles, their use was restricted to right heart contrast, when administered via a peripheral vein. This application included the detection of congenital or acquired intracardiac shunts, assessment of right-sided valvular regurgitation, and diagnosis of complex congenital heart defects and pulmonary arteriovenous fistulas. Although color Doppler, echocardiography now provides an easy method of detecting shunts, agitated saline has remained helpful in other areas such as quantifying tricuspid regurgitant velocities. [1] In the past, use of ultrasonographic contrast agents for left-sided imaging, however, could be performed only by direct injection of bubbles into the left atrium or ventricle.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
Initial studies aimed at detecting myocardial contrast used microbubbles produced by hand agitation or solutions containing carbon dioxide gas. Because of the short duration of the contrast, these agents were given either into the aortic root or directly into the coronary artery.[2] [3] [4] [5] [6] Since these studies, however, significant developments have been made in how intravenous microbubbles can be used to study myocardial perfusion. The stimulus for these developments includes an improved understanding of coronary physiology in patients with coronary artery disease, advances in ultrasonographic imaging, and the development of microbubbles that reach the coronary microcirculation after intravenous injection. The purpose of this chapter is to first illustrate the methods used to create ultrasonographic contrast. Second, we examine how these methods have been used to quantify myocardial perfusion, risk area, infarct size, and collateral blood flow with myocardial contrast echocardiography. Finally, 160
Figure 8-1 Effect of incorporating gases with lower diffusivity and solubility into microbubbles. When microbubbles contain only room air (RA) or sulfur hexafluoride (SF), an intravenous injection produces no myocardial contrast compared with baseline (BL). When these microbubbles contain a gas with low diffusivity and solubility such as perfluoropropane (PESDA), intravenous injection produces bright myocardial contrast. (From Porter TR, Xie F, Kilzer K: J Am Soc Echocardiogr 1995;5:710–718.)
the clinical applications of contrast echocardiography are reviewed.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/63.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Characteristics of Microbubbles Microbubbles have to meet numerous physical and chemical standards to reach the left ventricular cavity and myocardium following venous injection. The first requirement is size. Microbubbles of more than 8 µm diameter are filtered from the pulmonary circulation and will not reach the left ventricular cavity.[7] The scattering cross section of a microbubble is related to the sixth power of its radius, and thus the smaller bubbles that reach the left ventricle are less reflective than the bubbles filtered by the pulmonary circulation. To detect the comparatively weak echoes of the bubbles small enough for transpulmonary passage, imaging modalities have been developed that register the more "microbubble-specific" resonant frequencies. The resonant frequency of a microbubble is inversely related to its diameter.[8] Another problem arising with the small microbubble size requirement is surface tension. The internal pressure of gases within microbubbles is increased dramatically as the size of a microbubble decreases to less then 7 µm. Therefore, the gases within the microbubbles are at very high concentrations and rapidly diffuse into blood. This immediately reduces the size and hence the contrast effect, a limitation becoming most evident when attempts are made to obtain myocardial ultrasonographic contrast from an intravenous injection. The transit time required to reach the left ventricular cavity from an intravenous injection is greater than 5 seconds and, therefore, significant amounts of gas will have escaped from the microbubble at this point. Therefore, a second requirement for intravenous microbubbles is to have a method of preventing dissolution after exposure to blood. The gas composition is one of the most important factors for retention of microbubble size in circulation. First-generation contrast agents contained
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
room air, which is 78% nitrogen. Since nitrogen rapidly diffuses, these microbubbles survived only seconds.[9] To overcome this problem, slowly diffusing, insoluble gases were incorporated into the microbubbles. This improved the duration of ultrasonographic contrast in blood and even achieved myocardial contrast from an intravenous injection.[10] As shown in Figure 8-1 , by incorporating higher molecular weight gases such as perfluoropropane (molecular weight 188 g/mol) into microbubbles instead of room air, the same intravenous dose of dextrose albumin–coated microbubbles can produce a significantly greater amount of myocardial contrast than the same dose of microbubbles containing room air.
161
A third requirement is safety. Perfluorocarbon-containing microbubbles have been shown to have minimal toxicity in humans. The most frequent side effects noticed with Optison, the first and until now only secondgeneration ultrasonographic contrast agent approved by the Food and Drug Administration (FDA), are headache (5.4%), nausea and vomiting (4.3%), warm sensation or flushing (3.6%), and dizziness (2.5%). [11]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/64.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 4
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Ultrasonographic Imaging Techniques Although electromechanical sonication and fluorocarbon gases have rendered the microbubbles more stable, 163
their detection in the myocardium with echocardiographic equipment remained difficult with conventional imaging techniques. The invention of second harmonic imaging, intermittent imaging, harmonic power Doppler and, recently, pulse inversion Doppler and power modulation has dramatically enhanced the myocardial contrast produced from intravenously injected microbubbles. Second Harmonic and Intermittent Imaging Microbubbles in an ultrasonic field have the ability to scatter ultrasound not only linearly but also nonlinearly. At peak incident pressures (above 0.1 megapascals), the microbubbles respond in a nonlinear manner. This physical property is attributable to the fact that gas bubbles are compliant and react to insonification at diagnostic frequencies with compression and rarefaction, thus emitting radial oscillations. The magnitude of compression and rarefaction is not the same with each oscillation, and therefore both linear and nonlinear returning waves occur. [44] The nonlinear responses typically occur in harmonics and can be received and filtered by an appropriate echocardiography system. Since tissue and side lobes exhibit a significantly smaller nonlinear response to ultrasound (Fig. 8-3) , ultrasonic transducers that selectively receive the harmonic frequency produce a much better signal-to-noise ratio and more sensitive detection of microbubbles than conventional imaging.[45] Microbubbles are destroyed by ultrasound when it is transmitted at diagnostic intensities (mechanical indices >0.3). Destruction can be
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 4
reduced by selecting one image out of every one to several cardiac cycles, triggered to the electrocardiogram. This has been referred to as intermittent imaging. When the intermittent ultrasound impulse is at a high intensity (above 0.9 mechanical index), there is a strong and brief nonlinear echo. This transient scattering process is the third mode of action microbubbles show in an ultrasonographic field in addition to linear and harmonic response to ultrasound waves.[46] [47] Interrupting the high-intensity ultrasound for a short period of time allows for replacement of microbubbles, which then produce contrast enhancement for the following (triggered) frame. When microbubbles are administered as a continuous infusion and the ultrasound pulsing interval is incrementally varied, the reappearance of bubbles in the myocardium permits the calculation of mean microbubble velocity and plateau (or peak) myocardial signal intensity.[48] Multiplying these two variables together, one can better estimate myocardial blood flow. Therefore, with a combination of second harmonic and so-called intermittent imaging, it has become possible to noninvasively examine myocardial perfusion in animals and humans using a wide variety of intravenous higher molecular weight microbubbles.[8] [49] [50] [51] [52] (Harmonic) Power Doppler Power Doppler images are based on the integrated power in the Doppler signal instead of its mean frequency Figure 8-3 Illustration of returning signal intensity (indicated by arrow length). Microbubbles have the greatest harmonic signal intensity, but myocardium also has a harmonic response. Fortunately, the side lobe (SL) artifacts have very little harmonic signal intensity and thus do not reduce the image quality of a harmonic image as they do in fundamental images. (From Porter TR: Harmonic ultrasound imaging during routine and contrast-enhance echocardiography. Cardiac Ultrasound Today 1998;4:121.)
shift, as used in conventional color Doppler.[53] The amplitude of the Doppler signal is related to the concentration of scatterers at a particular location. This amplitude is much greater in the presence of microbubbles when compared with the signal of red blood cells.[54] This Doppler signal is more sensitive but, more importantly, is not subject to aliasing and is independent of the angle of insonation. It is, however, subject to flash artifacts, which occur with movement of the heart. Combining power Doppler with intermittent harmonic imaging (harmonic power Doppler) can
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 4
decrease these flash artifacts at the expense of real-time imaging. Harmonic power Doppler has been successfully employed in animal[55] and human myocardial perfusion studies, showing satisfactory concordance in the comparison between echocardiographic and 99m Tc-sestamibi single photon emission computed tomography (SPECT) stress imaging.[56] [57] Low Mechanical Index Imaging Accelerated Intermittent Imaging
As previously mentioned, microbubbles are destroyed when exposed to ultrasound at high power output. Although 164
interrupting the imaging process by taking triggered images helps keep a sufficient concentration of contrast agent in the myocardial capillaries, the dynamic character of the echocardiographic examination cannot be used with triggered or intermittent imaging. If the mechanical index is set low enough to prevent major bubble destruction, while still allowing the microbubbles to resonate, the image acquisition can be performed continuously (because of the higher frame-rate), and real-time data on both wall motion and perfusion can be obtained. This procedure, termed accelerated intermittent imaging, has proven to be extremely helpful, especially during stress echocardiography in humans.[58] [59] Pulse Inversion Doppler and Power Modulation
Another possibility for achieving real-time visualization of myocardial function and perfusion is the application of the recently developed pulse inversion technique. The intention of this new method is the separation of linear and nonlinear scattering using the radiofrequency domain. Alternately positive and negative pulses of identical amplitude are transmitted into the tissue, the sum signal of which is equal to 0 (Fig. 8-4) . The responses of linear scatterers to that kind of pulses, therefore, will be cancelled. On the other hand, the signal from nonlinear scatterers (which do not react to positive and negative pressures in the same way) will be unequal to 0 and can be registered as a bubble-specific response (see Fig. 84) .[60] Although pulse inversion is subject to motion artifacts, pulse inversion Doppler overcomes this by sending multiple pulses of alternating polarity into the myocardium. This allows one to visualize wall thickening and contrast enhancement simultaneously at very low mechanical indices
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 4
(<0.2) while maintaining an excellent signal-to-noise ratio. Initial studies using this technique in humans have demonstrated brilliant myocardial opacification from very small bolus injections of intravenous Optison.[61] [62] Figure 8-4 A depiction of how pulse inversion technology is able to enhance the signal-to-noise ratio from microbubbles at a very low mechanical index (<0.3). By sending pulses of alternating polarity, tissue signals cancel. Microbubbles, however, exhibit a nonlinear response to ultrasound even at these low mechanical indices, and hence the returning signals do not cancel. The resulting returning signal is a pure nonlinear response with almost nonexistent background signal. (Courtesy of Advanced Technology Laboratories, Bothell, Wash.)
Power modulation is another technique that improves the signal-to-noise ratio at very low mechanical indices. This technique, developed by Agilent Technologies (Andover, Mass), is also a multipulse cancellation technique, only here the power of each pulse is varied. The low-power pulses create a linear response, whereas the slightly higher power pulse results in a linear response from tissue but a nonlinear response from bubbles (Fig. 8-5) . The linear responses from the two different pulses (the amplified low-power pulse and the slightly higher power pulse) can be subtracted from each other; the transducer then only sees the nonlinear behavior, which emanates exclusively from the microbubbles. Both pulse inversion Doppler and power modulation can be used at very low mechanical indices to assess myocardial contrast in real time with excellent spatial resolution at higher band-widths.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/66.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 10
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Clinical Application of Ultrasonographic Contrast Via different injection routes, ultrasonographic contrast agents have been used to study various clinical problems in the cardiac catheterization laboratory and operating room, and now in the noninvasive setting (Table 8-2) . Detecting Acute Ischemia/Risk Area With Intracoronary and Aortic Root Injection
Prior to the development of stabilized perfluorocarbon microbubble contrast agents, clinical studies aiming at myocardial perfusion assessment mostly involved administration of air-filled microbubbles in the coronary arteries or aortic root. Bolus injections of air-filled microbubbles have been used to assess infarct size. Since microbubbles only enter regions where capillary integrity is preserved, this approach results in a more direct assessment of viability than definition of the contractile reserve. In several animal and human investigations, intracoronary ultrasonographic contrast injections have successfully delineated the area at risk after acute myocardial infarction, which is defined as the complete transmural extent of the perfusion bed supplied by an occluded coronary artery.[74] [75] [76] These studies have shown that area at risk measured with intracoronary contrast is superior to clinical, electrocardiographic, hemodynamic, or angiographic data in determining actual risk area. TABLE 8-2 -- Specific Clinical Applications of Myocardial Contrast Echocardiography Route of Injection Intracoronary
Clinical Parameters Measured Area at risk
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Aortic root
Intravenous injection or infusion
Intravenous infusion
Pagina 2 di 10
Perfusion bed size Infarct size Coronary flow reserve Collateral flow Area at risk Infarct size Coronary flow reserve Adequacy of cardioplegic delivery Adequacy of bypass graft perfusion Area at risk Infarct size No reflow Perfusion defect size Myocardial blood volume Myocardial blood flow Red blood cell velocity Subendocardial blood flow
168
Figure 8-10 An example of the myocardial ultrasonographic contrast produced with perfluorocarbon-exposed sonicated dextrose albumin (PESDA). A, Short-axis view of the left ventricle in an open chest dog with a left circumflex occlusion before contrast injection. B, Myocardial contrast in the anteroseptal myocardium after intravenous contrast, also illustrating a large contrast defect in the posterolateral left ventricular myocardium. C, After reperfusion, an intravenous injection of this perfluorocarbon-exposed sonicated dextrose albumin produces homogeneous contrast throughout the myocardium. With Intravenous Injection
As previously discussed, intravenous microbubbles encapsulating high molecular weight gases in combination with new imaging techniques have made the noninvasive assessment of myocardial perfusion with
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 10
echocardiography possible. These techniques have already been employed in clinical investigations and extend the findings of contrast studies performed with intracoronary and aortic root injections of contrast material. In several animal experiments, the spatial distribution of hypoperfusion after coronary artery occlusion and reperfusion has been accurately quantified with intravenous myocardial contrast echocardiography (Fig. 810) .[41] [77] [78] [79] Perfusion defects delineated by ultrasonographic contrast were found to correlate well with the extent of wall motion abnormality in the corresponding myocardial segment and postmortem measurement of risk area.[77] Peak myocardial videointensity within the hypoperfused segment following bolus injection of microbubbles has correlated closely with radiolabeled microsphere-derived flow in the infarct area.[41] Continuous infusions of microbubbles have been employed to quantify reductions in myocardial blood flow using the destruction-replenishment techniques described previously.[48] Assessment of the Effect of Myocardial Revascularization Intracoronary and Aortic Root Application
Intracoronary and aortic root injections of air-containing microbubbles have been used to assess the outcome of coronary angioplasty in patients with critical coronary artery stenoses.[80] Mudra et al[81] demonstrated that the half-time of contrast washout from peak myocardial videointensity after intracoronary contrast decreased after successful angioplasty. In their study, this rate of contrast washout from the myocardium returned to abnormal values when restenosis occurred. With intracoronary injection of sonicated albumin, Porter et al[82] described an immediate improvement in antegrade coronary blood flow reserve in a majority of patients who underwent angiographically successful angioplasty. The degree of improvement in diameter stenosis by quantitative angiography correlated closely with the magnitude of improvement in the area under the time intensity curve after intracoronary papaverine injection. Other investigators have demonstrated a correlation between the pressure gradient across a coronary stenosis before and after angioplasty and the degree of improvement in peak myocardial contrast produced by intracoronary contrast.[83] Identification of patients with the "no-reflow" phenomenon has been another important clinical application for intracoronary ultrasonographic contrast. This phenomenon, described first in an animal setting by Kloner et al in 1974,[84] is characterized by a lack of recovery in microvascular
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 10
perfusion although the occluded coronary artery is successfully reopened by angioplasty or thrombolysis. Ito et al[85] were the first to systematically examine myocardial perfusion with intracoronary microbubbles in patients with acute anteroseptal myocardial infarction immediately following restoration of antegrade flow in the left anterior descending artery. Using intracoronary sonicated radiographic contrast, they demonstrated that 23% of the patients had persistent contrast defects (i.e., no reflow) in the area at risk after recanalization. The long-term prognosis of these no-reflow patients was impaired, and there was significant deterioration in regional and global systolic function at follow-up. These findings have been confirmed by other investigators. Visualization of collateral myocardial blood flow before and after revascularization has been demonstrated with intracoronary contrast. In patients with occluded vessels, injection of ultrasonographic contrast material into adjacent coronary arteries can produce myocardial contrast enhancement in the perfusion bed subtended by the occluded vessel.[86] [87] This phenomenon is clinically relevant because it indicates viability of the perfusion bed subtended by the occluded coronary artery.[88] Sabia et al[89] demonstrated that revascularization of an occluded coronary artery after myocardial infarction improved function only when ultrasonographic contrast delivered into the 169
opposite coronary artery resulted in contrast enhancement to the perfusion bed of the occluded artery prior to revascularization.[90] The spatial extent of collateral blood flow as defined by contrast echocardiography correlated closely with improvement in regional function within the infarct zone. These observations suggest that intracoronary contrast echocardiography may be a valuable tool in determining whether revascularization procedures are indicated (Fig. 8-11) . When employed in the operation room during coronary bypass grafting, intracoronary and aortic root injections of ultrasonographic contrast agent have been useful in several aspects. The effectiveness of the saphenous vein graft has been determined by injection of air-filled microbubbles into the cross-clamped aortic root or directly into the graft.[91] [92] [93] Aortic root injections of microbubbles before cardiopulmonary bypass have also guided the sequence of bypassing.[94] The peak myocardial videointensity following intra-aortic contrast-enhanced cardioplegia injections has
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 10
correlated with the eventual improvement in wall motion after bypass grafting.[91] [95] Retrograde (via the coronary sinus) and antegrade cardioplegic delivery have been compared by using myocardial contrast echocardiography. In these small studies, retrograde delivery was found to be superior in providing myocardial perfusion in certain cases.[96] Keller et al[96] investigated the possibility of quantifying myocardial blood flow in the arrested heart during open heart surgery and found that the washout of microbubbles was markedly prolonged during antegrade crystalloid cardioplegia, so that it was no longer correlated with tissue flow (Fig. 812) . The washout delay appeared to be due to albumin microbubble adherence to the venules, suggesting that endothelial damage is caused by the cardioplegic solution.[97] This microvasculature damage could be partly Figure 8-11 Changes in myocardial contrast after intracoronary injection of contrast in both the vessel being dilated (recipient vessel area) and the coronary artery providing angiographic collaterals to the vessel being dilated before and after successful angioplasty in six patients. As can be seen, the amount of recipient vessel area contrast enhanced by the artery supplying collateral flow decreases significantly in most patients immediately after angioplasty. PTCA, percutaneous transluminal coronary angioplasty. (From Grill HP, Brinker JA, Taube JC, et al: J Am Coll Cardiol 1990;16:1594.)
Figure 8-12 Different time intensity curves from the myocardium at the same flow rate demonstrating the effect of the cardioplegia-arrested heart on washout of contrast material. This is markedly different than the washout of contrast material from a beating heart. (From Keller MW, Kaul S, Spotnitz WD, et al: J Am Coll Cardiol 1990;16:1267.)
avoided when cardioplegia was mixed with blood. The greater the amount of blood in the cardioplegic solution, the higher was the observed microbubble transit rate. [98] With Intravenous Injection
By using second-generation contrast agents and intermittent nonlinear detection modalities, several investigators have recently succeeded in detecting the no-reflow phenomenon from intravenous administration of microbubbles in patients with acute myocardial infarction following revascularization. Lepper et al[99] studied myocardial contrast enhancement in patients with acute infarction undergoing angioplasty immediately before
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 10
and 24 hours after recanalization using intravenous perfluorocarboncontaining microbubbles (NC100100; Nycomed Imaging AS) and intermittent harmonic imaging. An improvement of myocardial perfusion within 24 hours after intervention was predictive of functional recovery verified at 4-week follow-up. These investigators found that myocardial contrast imaging performed within an hour after revascularization is likely to lead to an underestimation of the ultimate infarct size. Actual infarct size in this time frame is best assessed following the use of a coronary vasodilatator. [100] Porter et al[101] used intravenous PESDA to identify patients with the noreflow phenomenon following successful restoration of antegrade flow after acute myocardial infarction (Fig. 8-13) . In concordance with previous studies using intracoronary contrast, lack of contrast enhancement in the perfusion bed of the infarct-related artery was predictive of a subsequent lack of recovery in both regional and global myocardial function. There are no human studies evaluating intravenous ultrasonographic contrast imaging for the detection of 170
Figure 8-13 Examples from two different patients who had anteroseptal and apical myocardial infarctions and similar wall motion score indexes following restoration of epicardial flow in the left anterior descending artery. The patient on the right had a persistent perfusion defect (no reflow, arrowheads), whereas the patient on the left demonstrated reflow in the same regions (arrowheads). MI, myocardial infarction. (From Porter TR, Li S, Oster R, Deligonul U: Am J Cardiol 1998;82:1173. Reprinted with permission from Excerpta Medica Inc.)
collateral vessels. However, Mills et al[102] studied the development of coronary collaterals flow in a canine model by examining the spatial and temporal course of a contrast defect following acute coronary occlusion using intravenous echocardiographic contrast and second harmonic intermittent imaging modalities. Thus, intravenous myocardial contrast echocardiography may be useful in assessing myocardial viability in the perfusion beds of patients with occluded coronary arteries. Detection of Coronary Artery Disease With Intracoronary and Aortic Root Contrast Injections
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 10
Early attempts to determine perfusion defects in patients with coronary artery disease were restricted to the catheterization laboratory. Cheirif et al [25] described in a canine model a close correlation between dipyridamole contrast echocardiography and thallium-201 SPECT in assessing the extent of jeopardized myocardium when moderate to severe degrees of coronary stenosis were present. DeFilippi et al[103] compared intracoronary myocardial ultrasonographic contrast enhancement with wall motion responses to dobutamine (contractile reserve) in 35 patients with chronic coronary artery disease. They found that both contractile reserve and myocardial contrast enhancement were predictive of functional recovery in hypokinetic segments following revascularization. Contrast echocardiography with intracoronary Albunex was used to identify myocardial hibernation by Nagueh et al[104] in patients with stable coronary artery disease and left ventricular dysfunction. These investigators reported myocardial contrast echocardiography, thallium-201 SPECT, and dobutamine stress echocardiography to be of comparable sensitivity in predicting functional recovery after revascularization, but specificity was highest with dobutamine stress echocardiography. With Intravenous Contrast Injections and Infusions
Until the last few years, radionuclide scintigraphy has been the diagnostic tool to address myocardial perfusion during stress testing. This method, especially when performed with 99m Tc rather than 201 Tl, provides high sensitivity in identifying patients with coronary artery disease. It is limited, however, by relatively poor spatial resolution and frequent attenuation artifacts. With intravenous perfluorocarbon contrast agents and nonlinear ultrasonographic techniques, detection of underperfused myocardial segments during stress echocardiography has become feasible (Fig. 8-14) . Using intravenous Optison and intermittent harmonic imaging, Kaul et al [105] described a 92% concordance between segmental perfusion scores by myocardial contrast echocardiography and 99m Tc-sestamibi SPECT at rest and during dipyridamole stress. Porter et al[52] likewise indicated a close correlation 171
Figure 8-14 (color plate.) Myocardial contrast produced from 0.3 mL
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 10
intravenous injections of Optison at rest (left) and during dobutamine stress (right) echocardiography in three different patients with significant coronary artery disease in three different coronary artery territories. Ultrasonographic imaging is done with pulse inversion Doppler, and this results in bright myocardial opacification in normal regions at mechanical indexes of 0.2 or less. A, Inducible anteroseptal and apical defect; B, inducible inferior perfusion defect; C, inducible lateral wall contrast defect. All patients were found to have greater than 50% diameter narrowings at coronary angiography in the left anterior descending (A), right coronary artery (B), and left circumflex artery (C), respectively.
172
between regional peak myocardial videointensity following intravenous PESDA and radionuclide tracer uptake during dipyridamole stress echocardiography performed with intermittent harmonic imaging. Most recently, Heinle et al[57] used an intravenous Optison infusion and harmonic power Doppler imaging at long pulsing intervals during adenosine stress testing to compare perfusion with 99m Tc-sestamibi SPECT in 123 patients with suspected coronary artery disease. There was an overall concordance between both techniques of 83%; concordance was higher in patients with no or multivessel coronary artery disease. Correlation was also dependent on which coronary territory was involved, with the best agreement occurring in the left anterior descending territory (81%). Agreement was not as good between the two techniques in the left circumflex (72%) or right coronary artery (76%) territories.[57] On a segmental basis, the highest concordance between techniques was in the midanterior septum (82%), whereas there was poor agreement in the basal lateral (51%) and posterolateral (59%) segments. This may be due to the fact that, even with continuous Figure 8-15 An example of an apical perfusion defect in the apical longaxis view (arrowheads) during dobutamine stress (bottom panels) using a continuous infusion of perfluorocarbon containing microbubbles. Under baseline conditions (top panels), no contrast defect was observed at incremental pulsing intervals. At peak dobutamine stress, an apical contrast defect was observed even at the longer 3000 msec pulsing interval. This patient had a totally occluded left anterior descending artery at angiography. DOB, dobutamine; PI, pulsing interval. (From Porter TR: Echocardiography 2000;17:92.)
infusion, assessment of the basal regions is often affected by attenuation. Nonetheless, use of a continuous infusion reduces attenuation artifacts and
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 10
provides more homogeneous myocardial contrast opacification. It also may eventually allow us to clinically quantify myocardial blood flow (Fig. 815) . In patients with coronary artery disease, a noninvasive diagnostic option for the definition of occlusion degree would be particularly helpful. Animal stress echocardiographic studies involving continuous perfluorocarbon microbubble infusion and intermittent harmonic imaging have shown a strong correlation between the severity of a coronary stenosis and the severity of a replenishment contrast defect at peak dobutamine stress.[106] Low mechanical index imaging techniques have recently emerged as a much more practical method of detecting myocardial perfusion abnormalities during stress echocardiography.[58] Cwajg et al[59] used accelerated intermittent imaging and intravenous bolus injections of Optison and PESDA at rest and during dobutamine stress 173
Figure 8-16 (color plate.) An example of real-time myocardial contrast enhancement produced with an intravenous Optison injection (0.3 mL) in one patient at rest (top panels), during intermediate dose dobutamine at 70% predicted maximum heart rate (middle panels), and during peak infusion at more than 85% predicted maximum heart rate (bottom panels). Note that with low mechanical index pulse inversion Doppler echocardiography, myocardial contrast enhancement is seen throughout the cardiac cycle. Note that there was an inducible anteroseptal and apical perfusion defect during stress, which became evident at the intermediate dobutamine infusion stage. ED, end-diastole; ES, end-systole.
echocardiography in 45 patients with known or suspected coronary artery disease. In this study, the real-time assessment of perfusion improved the sensitivity of the test in detecting angiographically significant stenoses by more than 10%.[59] More recent phase II studies have demonstrated the incremental value of myocardial perfusion assessment using accelerated intermittent imaging during exercise testing. [107] With the advent of pulse inversion Doppler echocardiography, low mechanical index imaging during stress echocardiography has higher spatial resolution and improved signalto-noise ratio (Fig. 8-16) . Distribution of Transmural Myocardial Blood Flow Because of the high spatial resolution of ultrasonographic imaging, several investigators have demonstrated differences in the degree of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 10
echocardiographic contrast produced by an intracoronary or aortic root injection between the subendocardial and subepicardial layers of myocardium. Animal studies even demonstrated after an intracoronary injection of a monosaccharide-based contrast agent (SHU-454) that differences in the transmural distribution of contrast could be detected at different times in the cardiac cycle.[107] Lim et al[108] demonstrated with an intracoronary injection of hand-agitated contrast material in humans that there was a lower subendocardial contrast intensity during pacing in regions supplied by a critical coronary stenosis. Although these findings in humans are promising, subsequent animal studies have not been able to confirm that intracoronary or aortic root injections of ultrasonographic contrast agent can distinguish subendocardial from subepicardial blood flow.[90] These investigators have shown that transmural attenuation of the myocardium caused by the contrast agent creates a false impression of relative decreases in subendocardial contrast. In addition, there are other limitations involved in using ultrasonographic contrast to define transmural differences in ultrasonographic contrast, such as (1) the nonspecific scattering properties of microbubbles, (2) the signalto-noise problems that occur even with epicardial imaging in differentiating the subendocardium from subepicardium, and (3) interference from scattering of microbubbles within the arterioles and venules. These same investigators, however, have demonstrated that the quantitative assessment of myocardial blood flow that can be achieved with a continuous intravenous infusion of microbubbles may also be able to delineate transmural differences. [109] In an open chest canine study, only the endocardial-to-epicardial ratio of the product of the initial contrast replenishment slope and plateau myocardial signal intensity correlated with radiolabeled 174
microsphere measurements, whereas transmural measurements of myocardial blood volume did not.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26040709/1031/68.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 7
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Other Intravenous Applications of Microbubbles Improved Endocardial Border Delineation Several different intravenous ultrasonographic contrast agents have demonstrated their ability to improve the diagnostic value of echocardiographic examinations in patients with suboptimal imaging conditions. In routine ultrasonographic examinations of patients with poor echocardiographic windows, contrast enhancement of the left ventricular cavity provides better delineation of the endocardial border. Clinically, this could give more information regarding regional and global systolic function that could not be assessed with routine echocardiography. Tissue harmonic imaging by itself has significantly improved endocardial border, often eliminating the need for intravenous ultrasonographic contrast agents filled with room air.[110] During the last few years, studies have shown that intravenous perfluorocarbon-containing microbubbles, because of their consistent left ventricular opacification, have improved border definition in the left ventricle of patients with suboptimal tissue harmonic images (Fig. 8-17) . Figure 8-17 An example of how intravenous perfluorocarbon microbubbles can improve endocardial delineation at end-diastole (DIAS) and end-systole (SYS) when compared with harmonic imaging above in a technically difficult patient. With the addition of intravenous contrast, the previously poorly delineated borders are now well visualized throughout the cardiac cycle. AC, after contrast; BC, before contrast. (From Porter TR: Echocardiography 2000;17:92.)
Optison proved its superiority over Albunex in a multicenter study that included 200 patients with suboptimal baseline pictures.[111] In this trial, full ventricular opacification could be achieved in 87% of the patients using the maximum intravenous Optison dose (5 mL), but only in 36% with optimal Albunex dosing (0.22 mL/kg). In patients with an echocardiogram that was
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 7
nondiagnostic because of poor images, the use of Optison resulted in diagnostic quality images in 74% of all cases, whereas the use of Albunex converted only 26% of poor-quality images to images of diagnostic value. Although the use of Optison increases the costs for routine transthoracic echocardiograms, substantial cost savings could still be made in the examination of patients with poor baseline harmonic image quality, because it would prevent the need for additional diagnostic studies in these situations. [112] Reilly et al[113] recently studied the effect of intravenous Optison injections in harmonic transthoracic echocardiography in the intensive care unit. Their results indicated a significant increase in interpreter confidence in evaluating myocardial segments that could not be analyzed without contrast application. Furthermore, the ability to estimate left ventricular ejection fraction was clearly improved with Optison. To accurately detect wall motion abnormalities during stress echocardiography, clear definition of endocardial borders is of particular importance. Several first-generation ultrasonographic contrast agents such as Albunex, 175
Levovist, and BY 963 have already been studied in pharmacologic and exercise stress tests, and all of the trials described better overall image quality at peak stress with these intravenous agents as compared with standard imaging.[114] [115] [116] [117] [118] [119] Contrast enhancement was especially helpful in interpretation of anterior and lateral wall segments.[119] Malhotra et al[120] most recently compared stress echocardiograms performed with both fundamental and harmonic imaging modalities with and without intravenous Optison contrast in 200 patients. They reported that the combination of harmonic ultrasonography with Optison resulted in the most consistent endocardial border delineation, which significantly exceeded the quality of either fundamental contrast imaging or tissue harmonic imaging alone. Interobserver agreement with Optison and harmonic imaging in this study was 95%. Unfortunately, in none of these studies has there been an analysis of whether improving endocardial border definition affects the sensitivity or specificity of the test when compared to radionuclide imaging or quantitative angiography. Contrast-induced homogeneous opacification of the left ventricular cavity
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 7
could also assist physicians in detecting left ventricular thrombi or tumors [121] [122] and complications of acute myocardial infarction such as myocardial rupture and left ventricular pseudoaneurysm.[123] It has also been used during transesophageal echocardiography to delineate false and true lumen in patients with aortic dissection.[124] Doppler Enhancement Intravenous microbubbles affect Doppler recordings because the scatter from them is much greater than from red blood cells. Microbubbles therefore can increase the signal strength in a Doppler examination markedly, which may be helpful in patients with suboptimal imaging quality. Von Bibra et al[125] described a significant enhancement of spectral and color Doppler and an increase in the signal-to-noise ratio in the quantitative assessment of aortic stenosis, pulmonary venous flow, and mitral regurgitation by intravenous injection of Levovist. Transthoracic pulmonary venous flow velocities have been improved by intravenous contrast enhancement to the point that they are comparable to those obtained with transesophageal imaging. [126] Moreover, intravenous microbubble ultrasonographic contrast was successful in providing a clear spectral signal across stenotic aortic valves, in cases in which the echocardiogram would have been nondiagnostic without contrast enhancement.[127] The gradients determined using contrast-enhanced Doppler signals correlated well with catheterization calculations. [127] Okura et al[128] studied the effect of Albunex in 45 patients with prosthetic aortic valves. They found a significant improvement in transvalvular continuouswave Doppler signal intensity with intravenous Albunex, increasing the frequency of satisfactory Doppler signals from 64% to 93% of patients. In patients with congestive heart failure, Kuecherer et al[129] used intravenous ultrasonographic contrast during exercise to evaluate cardiac functional reserve. They reported close correlation between echocardiographic estimation of systolic pulmonary artery pressure and invasively measured values both at rest and during stress testing. Safety of Myocardial Contrast Echocardiography There are no investigations in large study populations concerning the safety of intra-aortic or intracoronary application of microbubbles. In smaller studies, there have been isolated reports of transient chest pain after intracoronary sonicated albumin.[28] In a study of 18 patients given injections of intracoronary Albunex (commercially available sonicated albumin), 1 mL injections had no effects on systolic or diastolic function.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 7
However, 2 mL injections did transiently alter diastolic function.[130] The effects of ultrasonographic contrast agents compare favorably with the effects of radiographic contrast agents that transiently affected both systolic and diastolic function. Stabilized gas-containing intravenous microbubbles contained by albumin or lipid shells disrupt during insonication and are also pressure sensitive. The gas that is emitted from the bubble is excreted via the lungs, whereas the components of the shell are metabolized by liver enzymes. Perfluorocarbon gases are not metabolized but only exhaled. The safety of intravenous contrast agents containing high molecular weight gases has been tested in both animals and humans. The results of these studies suggest that perfluorocarbon-exposed sonicated dextrose albumin,[12] Definity,[131] Optison,[132] SonoVue,[133] and NC100100[134] all produce no significant hemodynamic abnormalities or serious side effects. After repeated intravenous application of Albunex over several months in 12 patients, there was no evidence of an immune reaction, such as IgE or IgG antibodies, and there were no adverse effects on left and right heart hemodynamics.[135] Animal studies have demonstrated bioeffects resulting from the interaction between microbubbles, low-frequency ultrasound, and tissue. Although both hemolysis and platelet lysis have been described in animal studies, to date these effects have not been observed in the clinical setting.[136] [137] Therapeutic Application of Microbubbles and Ultrasound A number of studies indicate that ultrasound microbubbles not only enhance the diagnostic value of an echocardiographic examination, but may also be used for therapeutic purposes. Drug Delivery
The fact that microbubbles are destroyed by the ultrasound beam has led to the study of their potential role in depositing adherent drugs or genes to an "ultrasound-targeted" organ.[138] Skyba et al[139] studied the intravascular destruction of perfluorocarbon-containing microbubbles 176
and the bioeffects of this process in the isolated spinotrapezius muscle of rats. With just one sweep of a diagnostic ultrasound transducer (2.3 MHz), microbubble destruction was observed that caused local microvessel
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 7
rupture. When the bubbles were mixed with colloidal particles, these particles were also "microinjected" into the interstitial space. The degree of microbubble destruction and resulting "drug delivery" was directly related to the mechanical index used.[140] Porter et al[141] demonstrated that perfluorocarbon-exposed sonicated dextrose albumin microbubbles bind large quantities of synthetic antisense oligonucleotides. These oligonucleotides are synthetic gene products that can be used to inhibit the translation of messenger RNA into proteins and enzymes that regulate pathologic processes such as neointimal hyperplasia following vascular injury. Their experiments indicated that external diagnostic ultrasound released the synthetic antisense into the insonified kidney if the antisense oligonucleotide was given intravenously bound to PESDA. In a recently published study, recombinant adenovirus containing β-galactosidase was attached to the surface of intravenously injected perfluorocarbon-containing albumin microbubbles and successfully targeted to the myocardium of rats by diagnostic ultrasound at a high mechanical index (1.5). Postmortem analysis showed β-galactosidase transgene expression in the myocardium after ultrasound antigene delivery, but no expression of the transgene in the control groups that had received Figure 8-18 (Figure Not Available) (color plate.) Echocardiographic delivery of microbubbles containing galactosidase (AdCMV-β-Gal). A, Short-axis view of rat heart reveals galactosidase staining 4 days after ultrasonic destruction of microbubbles carrying recombinant adenovirus containing β-galactosidase. B, Fast red stain of a 7 µm section from heart in A shows nuclear localization of galactosidase staining (× 20). C, Representative section from a control rat showing no galactosidase staining. D, Microscopic section from same control rat showing no galactosidase staining. (From Shohet RV, Chen S, Zhou Y-T, et al: Circulation 2000;101:1554, with permission.)
microbubbles alone, virus alone, or virus plus ultrasound (Fig. 8-18) (Figure Not Available) .[142] Targeted intramyocardial gene delivery has also been reported in vivo with lipid-encapsulated microbubbles. [143] Thrombolysis
Several investigators have examined the potential of high-energy ultrasound alone to dissolve thrombi in vitro as well as in an animal setting. Transcatheter ultrasound was able to reduce thrombus weight and possibly recanalize occluded femoral arteries.[144] Since this process involves cavitation, more recent investigations have focused on whether microbubbles could potentiate this phenomenon. When combined with intravenous perfluorocarbon microbubbles, low-
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 7
intensity, high-frequency ultrasound significantly increased the thrombolytic effect of urokinase in vitro. Even more importantly, ultrasound plus perfluorocarbon-containing microbubbles alone proved to be equivalent to urokinase in degree of thrombus dissolution. Therefore, it appeared that ultrasound and microbubbles could produce a localized clot lysis similar to a fibrinolytic agent without a systemic lytic state.[145] Invasive clot dissolution with therapeutic ultrasound and PESDA alone has been successfully tested in animal experiments. In a study involving 10 rabbits, iliofemoral arteries received 177
Figure 8-19 (Figure Not Available) Case example of angiography of both iliofemoral arteries following thrombotic occlusion of the iliac arteries (A and B). The right iliac artery was treated with intravenous perfluorocarbon-exposed sonicated dextrose albumin (PESDA) and transcutaneous ultrasound, resulting in recanalization after 30 minutes of therapy (C). The control side, treated with PESDA alone, remained occluded (D). (From Birnbaum Y, Luo H, Nagai T, et al: Circulation 1998;97:130, with permission.)
transcutaneous ultrasound treatment on one side and no ultrasound treatment on the other after an acute artery thrombotic occlusion. PESDA was given intravenously. After ultrasound treatment, all arteries that had received PESDA and ultrasound were recanalized by angiography, but none of the arteries treated with PESDA alone were patent (Fig. 8-19) (Figure Not Available) . Ultrasound alone also was unable to recanalize any of the thrombosed vessels.[146] Although more investigation on this field is required, the combination of ultrasound and microbubbles may turn out to be a promising alternative to the established thrombolytic strategies because of its ability to localize treatment to just the desired area. Detecting Inflammation
According to several experimental studies, albumin microbubbles used for ultrasonographic contrast enhancement persist in the myocardium in regions undergoing ischemia followed by reperfusion. The reason for this prolonged persistence is not exactly known yet. There is evidence, however, that endothelial glycocalyx damage and the presence of inflammatory extracellular matrix increase microbubble adherence to vascular endothelium.[147] [148]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 7
Lindner et al[149] hypothesized that during the early inflammatory response after reperfusion, activated leukocytes adherent to the venular endothelial surface may bind microbubbles and therefore prolong their transit. Using tumor necrosis factor-α injection in an animal setting, they have shown that both lipid and albumin microbubbles attach to activated leukocytes. The binding of the albumin microbubbles was mediated by β2 -integrins while the interaction between leukocytes and lipid microbubbles involved the complement pathway.[149] In a subsequent investigation, the involved leukocytes were identified to be mostly neutrophils and monocytes. Lipid and albumin microbubbles were phagocytosed by these cells and remained acoustically active for up to 30 minutes. During this time, they responded to ultrasound and could be detected in vivo after microbubbles from the blood pool had already vanished (Fig. 8-20) (Figure Not Available) .[150]
These findings describe the potential of microbubbles to noninvasively assess inflammation and may even lead to a possibility for drug delivery to the affected organ system. Furthermore, since albumin-coated microbubbles adhere to sites where vascular endothelial damage occurs, 178
Figure 8-20 (Figure Not Available) Effects of single pulses of ultrasound (P1 through P4 ) at different peak negative acoustic pressures on phagocytosed albumin-coated microbubbles. Note that neutrophil cell membrane disruption and distortion occurred at higher peak negative pressures (- 1600 kPa). BL, baseline. (From Lindner JR, Dayton PA, Coggins MP, et al: Circulation 2000;102:531, with permission.)
this may be a method of targeting the delivery of drugs bound to the microbubble without ultrasound. For example, we have recently demonstrated that PESDA microbubbles can concentrate the delivery of the antisense to the c-myc protooncogene to balloon-injured sites in the coronary artery and thus prevent neointimal hyperplasia.[151]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/69.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Summary The use of intravenous microbubbles for perfusion imaging is now a realtime reality. Future multicenter studies will demonstrate whether there is an incremental clinical benefit to examining myocardial perfusion during stress echocardiography and in acute coronary syndromes. Intravenous microbubbles also have a potential therapeutic role in the areas of targeted drug delivery, enhancing thrombolysis, and detecting inflammation.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/70.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
183
Chapter 9 - Interaction of Ultrasound with Tissue, Approaches to Tissue Characterization, and Measurement Accuracy Roy W. Martin PhD
The purpose of this chapter is to provide insight into what happens when a beam of ultrasound is launched into the body. What are the factors that affect this interrogating energy? How does it interact with the tissue and return reflected information to us? What can contaminate this returned information? What influences the accuracy of the information, and how may we further use information that is present in the signal but has largely been ignored? The answers to these questions provide understanding of common problems encountered daily (such as imaging artifacts and concern about the accuracy of measurements we make from these images). Furthermore, they also provide understanding of methods that extend beyond conventional imaging, such as feature extraction, border detection, and tissue characterization. The thrust of this chapter is to provide insight into basic fundamentals and then to apply those fundamentals to aid in understanding some tissue characterization methods, the recent developments in harmonic imaging, and several measurement errors.
MD Consult L.L.C. http://www.mdconsult.com
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 8
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Beam Patterns Ideally, we'd like to generate an infinitely narrow pencil beam of ultrasound that could be swept rapidly through the tissue, thereby interrogating all the regions of interest. Unfortunately, as we currently understand the physics of the problem, ultrasound energy doesn't allow this; instead of being narrow like laser beams, the beams are more like broad flashlight beams. Furthermore, the intensity is not uniform within and throughout the beam. This lack of a narrowness and uniformity leads to measurement errors and can contribute to artifacts. In addition, we would ideally like to be able to generate infinitely short pulses of ultrasound energy, but this is also only approximated in practice. Short pulses are easier to generate than narrow beams and therefore are not addressed in the chapter. Aperture The general term aperture refers to an opening through which radiation passes. In ultrasound transducers, aperture refers to the active surface of the transducer that emits or receives ultrasound waves. The behavior of these waves is similar to that of a plane wave passing through a hole that is the same size and shape as the active surface of the transducer; therefore, the use of the term has evolved. Several examples of commonly used apertures are shown in Figure 9-1 . With respect to the wavelength λ of the ultrasound, the size of the aperture of the ultrasound transducer is responsible for the overall beam pattern. The focusing and excitation patterns provide further modification to this general pattern. The wavelength of the sound is equal to the speed of sound c, in the media adjacent to the transducer divided by the ultrasound frequency f (i.e., λ = c/f). For example, because the average value of the speed of sound in tissue is 1540 m per second, then at 3 MHz, λ = 0.5 mm. Consider a circular aperture as shown in Figure 9-1A . If the radius of the aperture, a, is much less than the wavelength, the beam pattern is very
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 8
broad, whereas if the aperture radius is much greater than the wavelength, the beam is narrower in the region referred to as the far field. In addition, other features of the beam patterns are influenced by the radius-towavelength size. A radius of approximately 10 times the wavelengths has been found to be a good compromise (i.e., a/λ = 10). The beam 184
Figure 9-1 Geometry of various apertures of transducers used in medical ultrasound. A, circular disc; B, square; C, rectangle; D, annular array; E, square array aperture; F, rectangular array aperture; G, annular aperture; H, small rectangular aperture. Note that D is composed of an assemblage of annular apertures such as G and that E and F are composed of sets of small rectangular apertures such as H.
patterns for three ultrasound frequencies at which this ratio is constantly maintained are shown in Figure 9-2 . [1] [2] The different patterns in the near field and far field of the transducer are seen in Figure 9-3A . Regions of increasing and decreasing pressure isocontours are present in the near field. This near-field effect is due to wavelets from various regions of the aperture arriving at different phases at several points in the near field. Consequently, these wavelets add and subtract depending on their relative Figure 9-2 Beam pattern (3 dB below the axial value) is shown for three circular apertures where a/λ = 9.7. The apertures lie in the x-plane and y-plane at the base, and the ultrasound energy radiates vertically in this illustration (z-direction). The ultrasound frequencies and radius of each aperture (from left to right) are 5, 3.5, and 2 MHz and 0.3, 0.43, and 0.75 cm, respectively. Note that the point along the z-direction where the beam is the most constricted for each aperture is known as its near-far field transition. Points closer to the aperture are in the near field, whereas further points are in the far field. (Data from Weyns A: Ultrasonics 1980;18:183–188.)
phase with respect to each other. In the far field, this phenomenon is not present because they are all of the same relative phase. In the transition region between the near field and the far field, the beam pattern becomes much narrower and there are no pressure fluctuations because of little difference in the phase of arriving wavelets. The distance at which this transition occurs (the extent of the near field) can be calculated easily for a
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 8
disc transducer[3] [4] as near-field distance = a2 λ. In the far field the beam pattern increases progressively with distance because of the uniform spreading of the propagating energy. The excitation of the transducer with a short (instead of a continuous) tone burst reduces the complexity of the pattern in the near held (see Fig. 9-3B) . A common method of increasing the resolution in a portion of the imaging region is to introduce focusing into the transducer. The modification of a flat disc aperture to a curved aperture is illustrated in Figure 9-3C .[2] [5] The effect is like "pulling" the center of the flat aperture to the left, which also pulls the transition of the near field to far field to the left while decreasing the diameter of the beam in this region. A further effect is increasing beam divergence in the far field. The more the aperture is "pulled" to the left, the sharper the focusing becomes (i.e., the narrower the beam, the closer the focused region is to the transducer, and the greater the divergence of the beam in the far field) (Fig. 9-4) . Square and rectangular apertures ( see Fig. 9-1B and Fig. 9-1C , respectively) have beam patterns (Fig. 9-5) somewhat different from those of the disc-type of transducer (see Fig. 9-2) . First, symmetry is lost. The pattern is the same along the x-z–plane as the y-z–plane at the origin of the x-y–plane. However, at diagonal points, the pattern differs from the axial plane patterns. The rectangular aperture even differs at the x-z– to the y-z– planes. The near field, the distance to the transition, and the far fields all differ because the aperture distance to wavelength varies for these cases. The diagonal varies even further. Arrays The arrays that are commonly used have properties similar to those of the apertures discussed earlier. The structure of the arrays is illustrated in Figure 9-1 ( see Fig. 9-1D , an annular array; Fig. 9-1E , a square array; and Fig. 9-1F , a rectangular array). The annular array is composed of annular elements, such as the element illustrated in Figure 9-1G , and the square and rectangular arrays are composed of elements as illustrated in Figure 91H . The overall beam pattern considerations of an array are determined by the overall size of the array.[4] Therefore, if the radius-to-wavelength ratio of the annular array (see Fig. 9-1D) is the same as that of a solid disc (see Fig. 9-1A) , then the beam patterns are very similar (e.g., patterns such as those of Fig. 9-2 , Fig. 9-3A , and Fig. 9-3B ). A like consideration applies to the square and rectangular arrays ( see Fig. 9-1E versus Fig. 9-1B and
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 8
Fig. 9-1F versus Fig. 9-1C , respectively). The individual elements of the arrays have their own beam patterns, but an assemblage of multiple array elements gives the overall aperture pattern. It is of interest to consider the miniature element in Figure 9-1H . The 185
Figure 9-3 The 3-dB isocontours for beam patterns along a plane passing through the axis of the transducers. On the left the edge view of the transducer on this plane is illustrated. A, Continuous wave pattern for a disc transducer. B, Beam pattern for the transducer in A but resulting from a very short tone burst of excitation (e.g., two cycles). C, Transducer surface that has been made curved (e.g., spherical curvature) showing how applying such a curvature changes the beam pattern from a flat disc (dotted pattern) to a more focused pattern of the curved surface disc. The arrows indicate the direction the pattern changes as a flat transducer becomes spherical. (Data from Weyns A: Ultrasonics 1980;18:183–188, 219–223.)
pattern of this rectangle element is similar to the pattern of Figure 9-1C except that the dimensions with respect to the wavelength are different. The vertical length of the array element (see Figure 9-1H) Figure 9-4 Beam pattern (3 dB below the axial value) for three circular apertures where a/λ = 9.7. The apertures lie in the x-plane and y-plane at the base, and the ultrasound energy radiates vertically in this illustration (z-direction). Right, for a disc transducer; center and left, for spherically focused transducers with the same aperture size as the disc. The radius of the spherical surface for the left pattern is much less than the radius for the center figure, thus increasing the focusing effect. (Data from Weyns A: Ultrasonics 1980;18:219–223; and Kossoff G: Ultrasound Med Biol 1979;5:359–365.)
is the same as the vertical length of Figure 9-1C ; therefore, the beam patterns in the vertical direction are the same. However, the horizontal width of the element (see Figure 9-1H) is very small in contrast to the horizontal width of the square or rectangle aperture of Figure 9-1B or Figure 9-1C . Therefore, in a horizontal plane the beam Figure 9-5 Beam pattern (3 dB below the axial value) for a square aperture (left) and a rectangular aperture (right). The apertures lie in the x-plane and y-plane at the base, and the ultrasound energy radiates vertically in this illustration (z-direction). For the rectangular aperture
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 8
(right), the near-field to far-field transition distances are different along the x-axis versus the y-axis. Also, beam pattern spreading is different in the far field. (Data from Weyns A: Ultrasonics 1980;18:183–188.)
186
pattern transition of the near field to the far field occurs very close to the face of the element, and the far-field pattern diverges greatly and almost immediately in front of the face of the element. In fact, for a proper array, the element has a beam pattern that is so broad (approaching 180 degrees in angle) that its pattern overlaps with the patterns of all the other elements of the array. This overlap allows the array to have an overall pattern nearly identical to that of a solid aperture of the same size as the array. The real difference between an array and a single-element transducer is that each element in the array is connected to the electronic system, and therefore individual control of the timing associated with the transmission and reception of ultrasound is possible. For example, during transmission from an annular array, a beam of ultrasound energy is launched that focuses at a point similar to that discussed for a curved surface (see Fig. 9-3C) . This action is accomplished by exciting the outer element of the array first and then progressively exciting each annular element slightly later as one moves toward the center of the array. The real advantage is that the focus point can be electronically controlled by varying the respective time delays between elements. The greater the delay, the sharper the focus. During reception, by delaying the signals received by each element in a similar but inverse manner (across the array), one can achieve focusing comparable to transmission focusing. These signal delays are instituted before all the signals from each array element are combined to represent the A-line echo. However, the receiving situation is even more advantageous than transmission. Because the amount of delay imposed across the array can be varied continually as the signals are received, tracking the propagating wave is possible; that is, the receiving focus can move and remain pinpointed on the position of the transmitted burst of energy as it propagates away from the transducer. This action is called dynamic focusing and provides a narrower receiving beam over a much larger axial length than that which occurs without such focusing. It is worth noting that during the transmission of a burst or pulse of ultrasound, the focal point can be set only when the beam is launched. Therefore, only a fixed focal point can be used for transmission, but a dynamically tracking focus can be used
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 8
during reception. Many systems use multiple transmissions, varying the focal point each time and using only the information received from each focal region, thereby blending the transmissions to make a composite received line. This approach, however, slows down the scanning rate, as each line requires several transmissions. This method is widely used in noncardiac scanning, in which a high imaging rate is not so important. Therefore, when multiple focusing positions, or zones, can be set (as is possible with some ultrasound machines), one must check that the frame rate is still fast enough for the desired purpose. Further electronic "tricks" can be employed to improve the beam pattern in modern ultrasound instruments. For example, rather than use the whole array when imaging near the transducer, one may use a smaller group of elements for that zone, which increases resolution in the near region. A further improvement is to use for each focusing zone the number of elements that gives the best resolution (e.g., a small group for the focusing zone nearest the transducer, a somewhat increased size for the next zone, and similar increasing sizes for each zone located farther from the transducer). Other improvement methods include apodization, tissue aberration correction, and synthetic apertures. A similar discussion to the annular array, regarding using delays across the array for focusing, also applies to square and rectangular arrays. However, the focusing pairs of elements are located an equal distance (but opposite) from the horizontal center line of the array, and they are not connected together as in the annular array. Furthermore, because each element can be controlled electronically in addition to focusing the array, one can also steer the beam to produce electronic scanning of a region. This electronic scanning is in contrast to the annular array, which must be mechanically swept to interrogate a region of tissue. Electronic scanning is accomplished by adding a linearly increasing delay to the elements, proceeding from one side of the array to the other. This action allows launching and receiving a beam at an angle with respect to the face of the array. The amount of delay used, or the slope of this linearly increasing delay across the array, determines the amount of the steering angle produced. Therefore, to perform a sector scan, one changes the slope of delay profile across the array between scan lines, proceeding to scan from one side of the sector to the other. A shortcoming of the square or rectangular arrays discussed is that electronic focusing occurs only in the horizontal direction ( see Fig. 9-
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 8
1E and Fig. 9-1F ) because there is no electronic control in the vertical or elevational direction. In contrast, the annular array produces symmetric focusing around the axis, thereby usually producing markedly improved resolution. Consequently, there has been interest in designing rectangular arrays that have some or complete control of the beam pattern in the elevation direction as well. Two-dimensional (2D) or 11/n dimensional arrays are being employed for focusing in the elevational direction. (The 1/n implies that some amount of an array is distributed in the elevation direction, but it is less than a full assemblage of elements compared with the lateral direction.) The simplest designs have been referred to as 11/2 dimensional arrays, arrays in which a small division of the aperture has been made in the vertical direction (Fig. 9-6A) . It is not necessary to have separate transceivers for each vertical element here because it is possible to electrically wire together elements that are symmetrically displaced around a horizontal center line. For example, in Figure 9-6A , the vertically displaced elements associated with row 1 can be electrically connected together, as can elements labeled 2 in the figure. (Note: Only the individual elements in a column can be thus connected or the ability to sector scan would be lost.) By connecting elements in this manner, one can use phasing delays between numbers 1, 2, and the center element to produce focusing in the vertical direction at any of the horizontal steered angles, thereby improving the spatial resolution of the beam. In order to accomplish this, one needs only three times as many transceivers, even though the number of elements in the array has been increased five times. Of course, more than five elements can be used in a column 187
Figure 9-6 Two styles of array design offering added electronic beam control in comparison with the arrays of Figure 9-1 . A, So-called 11/2 dimension array offering electronic focusing in the vertical or elevational direction as well as full scanning control in the horizontal or lateral direction. B, Two-dimensional array offering complete three-dimensional beam scanning.
to provide even greater improvement, giving rise to the 1/n nomenclature. The complete 2D array of Figure 9-6B allows complete control of the beam in three-dimensional (3D) space if each element is connected to a
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 8
transceiver and the delay control for each element is provided in the ultrasound system.[6] The problem is that achieving 3D resolution equivalent to current 2D imaging requires many elements and transceivers. For example, a 64-element array and a 3D scanning system equivalent to a 2D array would need 64 × 64 (or 4096) elements, as well as electric connecting wires, transceivers, and delay control elements. The fabrication and cost of such a system are formidable, but they may be less so in the future. A less complicated electronic system, using a 2D array, has been clinically tested for producing biplane images.[7] With this latter approach, the array elements are connected through a multiplexing method to a standard 2D scanning system in such a way that sector scanning can be performed in the horizontal plane; then the array is switched so scanning can occur in the vertical plane. Undoubtedly, numerous permutations of approaches between a full array and multiplexing of the array will emerge in the near future.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/73.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 10
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Ultrasound Properties of Tissue There are four main acoustic or ultrasound properties of tissue: the velocity of propagation, acoustic impedance, attenuation, and the scattering of ultrasound. The first three of these are discussed in this section; the following section is dedicated to a more in-depth discussion of scattering. Velocity, impedance, and scattering are interrelated, and they all relate to the various constituents of different types of tissue as well. These parameters for most tissues have been measured,[8] [9] [10] but the published values vary greatly. This variation is due to differences in measurement methods, conditions of measurement (e.g., frequency, temperature), species tested, and tissue conditions (e.g., excised, fresh, fixed). Velocity of Propagation The velocity of propagation is fundamental to all ultrasound assessments. The commonly used average velocity of tissue at 37°C is 1540 m per second, which is used by most ultrasound machines for displaying calibration markers. Of course, individual tissues vary from this value, as illustrated in Table 9-1 . An approximate range of soft tissue variation for most tissue of usual concern with ultrasound is ±5%. The speed of sound also varies with the temperature of the tissue. Generally, most tissues have a small increase in speed as the temperature increases (a positive temperature coefficient); however, fat tissue has been found to have the opposite effect—a decrease in velocity occurs as temperature increases. [11] For in vitro experiments it is valuable to use water solutions that have the same speed of sound at room or body temperature that tissue has at body temperature. Speed regulation can be accomplished by varying the salinity of the water, as listed in Table 9-1 .[12] The speed of sound, c, in homogeneous media is given by the equation c = (β/ρ)1/2
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 10
where β is the bulk modulus of the media and ρ is the density.[4] The stiffer a material, the greater its bulk modulus. It is generally believed that the bulk modulus varies more than density, and that it is therefore the primary factor accounting for the variation in velocity. Acoustic Impedance The second parameter, acoustic impedance, z, is related to velocity and density: z = ρc = ρ(β/ρ)1/2 = (βρ)1/2 Among other things, acoustic impedance is a useful parameter for assessing the amount of reflection and transmission that can occur at the boundary of two layers of tissue. The acoustic reflection coefficient Rc , which is defined as the ratio of reflected acoustic pressure pr to the incident acoustic
pressure pi on the boundary, is given as pr /pi = Rc = (z2 − z1 )/(z1 + z2 )
where z1 is the acoustic impedance of the first medium and z2 is the impedance of the second medium.[4]
The transmission coefficient Tc is defined as the ratio of the acoustic
pressure transmitted pt into the second medium with respect to the acoustic pressure incident on the boundary from the first medium[4] pt /pi = Tc = 1 + Rc
188
TABLE 9-1 Impedance Velocity Density * (106 Temperature Other 3 Material (m/s) (kg/m ) kg/m-s) (°C) Conditions
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 10
Air
343
Lung (bovine)
570 gv 360
Lung 640 gv (bovine) Lung 710 gv (bovine) Lung 830 gv (bovine) Lung 860 gv (bovine) Water 1482 [14] Water 1476 Water 1497 Water 1488 Water 1509 Water 1540
1.2
0.000415
20
0.21
22
430
0.28
22
540
0.38
22
640
0.53
22
720
0.62
22
998 [89] 1.48 [14, 89]
20 22 37 22 37 22
38
0% salinity [4] 0% salinity [4] 0.9% salinity [12] 0.9% salinity [12] 4.62% salinity [12] 3.10% salinity [12] 44% hematocrit [88] 40% hematocrit [88] Peritoneal, 1–7 MHz [16] Stomach, 5 MHz [11] Breast [14]
37
Orbital, 6–7 MHz
Water
1540
37
Blood
1556 [88] 1579 [88] 1580
23
Blood
Fat (bovine) Fat 1412 (canine) Fat 1435 (human) Fat 1462
1055 [89] 918
1.67 [88, 89] 1.45
Atmospheric pressure [4] 66% inflated, 0.55 MHz [89, 90] 60% inflated, 0.55 MHz [89] 49% inflated, 0.55 MHz [89] 64% inflated, 0.55 MHz [89] 32% inflated, 0.55 MHz [89] 0% salinity [14]
37 20 37
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
(human) Liver (human) Liver (human) Liver (canine) Spleen (canine) Kidney (canine) Muscle (canine) Muscle (human)
Pagina 4 di 10
1584 [16] 1607 [16] 1596
1064 [89] 1064 [89]
1.69 [16]
20
[14] 1–7 MHz [16]
1.71 [16]
37
1–7 MHz [16]
37
5 MHz [11]
37
5 MHz [11]
37
5 MHz [11]
37
Skeletal, 5 MHz [11] Cardiac, perpendicular to fiber, 5 MHz [92] Cardiac, parallel to fiber, 5 MHz [92] Pig, age 5 mo, 15 MHz [91] Achilles, perpendicular to fiber, 5 MHz [30] Achilles, parallel to fiber, 5 MHz [30] Skull, outer table [93] Skull, inner table [93]
1601 1569 [11] 1593
1040 [89]
1.63 [11, 89]
1530
1052
1.61
18
Muscle 1555 (human)
1052
1.64
18
1094
1.87
25
1050
1.75
20
1050
2.12
20
1880
5.43–5.68
37
1910
4.56–5.52
37
*
*
Skin 1710 (porcine) Tendon 1670 (bovine) *
Tendon 2020 (bovine) *
Bone (human) Bone (human)
2890– 3020 2389– 2390
*Formalin fixed. gv, group velocity; [], reference number.
Attenuation
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 10
The third parameter, attenuation, is defined as the loss in the amplitude of an acoustic signal as it propagates. This parameter is responsible for the decrease in the echo signal strength at greater imaging depths, and it is why time-varying gain compensation is used in almost all ultrasound machines. It has been observed that the amplitude of a wave decreases with distance in a logarithmic manner. This phenomenon was first observed with light and has been credited to Beer, Lambert, and/or Bourgher (not necessarily in that order). (Various texts and literature seem confused about whom to credit, and they refer to it as the Beer law, the Lambert law, or various combinations of their names [e.g., Beer-Lambert-Bourgher law].) The phenomenon can be described as follows: For a propagating acoustic pressure wave, if the pressure at point 1 is defined as p1 and the pressure at point 2 a further distance l (in centimeters) from the first point is defined as p2 , then the attenuation between the two points can be given by p2 = p1 e−αl where α is the attenuation coefficient defined in nepers per centimeter (Np/cm), or just cm-1 . Alternative units for the attenuation coefficient (αdB ) are decibels per
centimeter and directly relate acoustic pressure and distance to attenuation, p1 /p2 l = αdB . It is easily shown using logarithms that αdB (dB/cm) =
8.686α (Np/cm), which is a useful constant, because the attenuation coefficients are often given both ways. Finally, it is worth pointing out the relationship of attenuation with respect to intensity of ultrasound. The intensity I of an ultrasound wave has units of watts per centimeter squared and is defined as the average power of a wave per unit area (in centimeters squared). The intensity is related to the amplitude of the acoustic pressure p in most cases by the following equation: I = p2 /2z where z is the acoustic impedance as defined earlier. Therefore, for a propagating wave, the intensity at point 1, I1 , is related to the intensity at a point 2, I2 , located a distance l away by the following equation:
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 10
I2 = I1 e−2αl The difference from the acoustic pressure equation is the 2 in the exponent.
189
The attenuation coefficient by itself does not separate out various mechanisms responsible for the loss of energy from the propagating wave. In order to provide further distinction, the attenuation coefficient has been defined to describe the scattering loss from the wave and the absorption of energy from the wave. The scattering directs energy in other directions, and the absorption describes the amount of energy in the wave turned into heat. The coefficient α is then defined as α = αs + αa , where αs is due to scattering and αa is due to absorption. One has to be careful in taking
coefficients from the literature because the distinction is not always made. Particularly in early work, the attenuation was called the absorption coefficient, because researchers did not realize that the scattering effect entered into their results. In fact, it is difficult to measure these effects in isolation. The next two important aspects of attenuation are that it is temperature- and frequency-dependent. Most tissues (not bone) have a negative temperature coefficient. [13] [14] Fat, as discussed later, has a high negative coefficient. All tissues have a strong frequency effect, with the attenuation coefficient varying directly with a power of frequency. For example, α = afb , where f is the frequency and a and b are constants. The power term b varies from 1 to as high as 4; the latter number is for αs , when scatters are much smaller than the wavelength (as discussed later in the scattering section). Most tissues have a coefficient b ranging between 1 and 2. The b (power of the exponent) attenuation factor for water is 2, because absorption is related to the viscosity of the water and the square of the velocity of particle motion. Absorption in tissue is believed to be related to the relaxation processes in the tissue,[15] but this is still not fully understood. The high dependence of the attenuation on frequency is why high-frequency transducers are not used to image deep in the body. The depth in the body at which one can image is inversely related to the ultrasound frequency used. This fact is emphasized by the expression of the attenuation coefficient as α/f in much of the literature. In considering the attenuation as a function of frequency,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 10
from the excellent compiled data,[9] [10] it is useful to fit a polynomial function to several of the tissues in which the simple expression (α = afb ) does not provide an adequate fit. The results of this equation and the simpler expression for attenuation for several tissues are given in Table 92 . Note: These fitted equations apply only in the specified frequency range designated; if applied out of that range they may provide erroneous results. TABLE 9-2 -- Approximate Ultrasound Attenuation Coefficients Material Air
Lung Water Blood
Fat
Liver Muscle Skin Bone
α(Np/cm) 1.86 × 10-13 f2
Comments Dry, 1 atmosphere
1.98 × 10-13 f2 + 6.36 × 10-7 f + 3.47 Canine, 1–5 MHz
Kinsler et al
8.1 × 10-15 f2 9.77 × 10-16 f2 + 1.09 × 10-9 f -6.22 × 10-15 f2 + 2.45 × 10-7 f 0.127
[4]
45% Goss et al[9] hematocrit, 2–50 MHz Pig back, 2– Gammell et 20 MHz al[13] Taniguchi et al[95] Goss et al[9]
1.3 × 10-7 f
[10]
Goss et al[9]
2.0 × 10-7 f 1.59 × 10-16 f2 + 2.55 × 10-8 f 0.0195 -4.01 × 10-19 f3 + 2.16 × 10-12 f2 4.12 × 10-7 f
Reference Tempest and Parbook[94] Goss et al[9]
[10]
2.0–10 MHz Goss et al[9] [10]
0.25–3.5 MHz
Goss et al[9] [10]
Fat seems to be a special tissue that is worth discussing briefly because it probably is responsible for the fuzziness of transcutaneous echocardiograms in many people. The reported measurements for fat are
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 10
puzzling because of the dispersed range of attenuation values reported.[8] [9] [10] This variation may be partially caused by differences in measurement techniques. However, the attenuation of fat is known to exhibit a strong temperature dependence, and if the temperature at which the attenuation measurements were made is not reported it is difficult to make comparisons. For example, it has been shown that attenuation of excised mammalian fat samples at body temperature is much less than that taken at room temperature.[13] [16] Furthermore, the freshness of the specimen, the species and breed of the donor, and the region in the body from which the specimen is required may also play an important role in the value of attenuation measured. [13] Finally, because of the energy storage function of adipose tissue and the variation in lipid concentrations in adipocytes (adipose cells) in relationship to the degree of obesity,[17] the nutritional state of the donor could also affect the attenuation measurements obtained within a given species and region of the body. In general, the major fat tissue, white adipose tissue, is known to consist of cells 25 to 200 µ in diameter, composed of weight of 60% to 80% lipid, 5% to 30% water, and 2% to 3% protein. From 90% to 99% of the lipid is triglyceride. [18] These adipose cells are held in "grapelike" aggregates by connective tissue called lobules.[19] The cell sizes have been correlated with the degree of obesity (hypertrophic obesity). [17] In some tissue regions (hyperplastic obesity) the number of the cells correlates more strongly with obesity. For example, a general trend in male humans is hypertrophic obesity in the abdominal regions, whereas female humans show hyperplastic obesity in the subcutaneous femoral and gluteal fat depot regions.[20] The average size of adipocytes in pigs and sheep has been reported to be greater in the omental and the perirenal regions than in the subcutaneous region, whereas in humans the reverse has been found.[17] Cell diameters ranged from 25 to 180 µ in adult pigs ready for market.[17] As discussed later, the size of a scatter with relationship to the wavelength of the sound can affect the frequency dependence of the scattering. Therefore, the nutritional state and location of the fat may affect its attenuation properties. The other interesting constituents of tissue are water and collagen. Water and collagen tend to have opposite 190
effects on ultrasound attenuation. Water content generally reduces
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 10
attenuation, whereas collagen increases attenuation.[21] [22] [23] [24] [25] Because water itself has a low attenuation in contrast to tissue, it is reasonable to expect that as the water content increases, the attenuation coefficient decreases. Fields and Dunn[26] in 1973 were the first to relate how the prominent differences in values of modulus between collagen and muscle may apply to the ultrasound echo properties of tissue. They pointed out that the low-frequency elasticity constant of collagenous fibers from tendon is about 1000 times greater than that of other tissues (e.g., 109 dyne/cm2 for collagenous fibers versus 105 to 107 dyne/cm2 for smooth muscle, [27] 2 × 108 dyne/cm2 for human calcaneal tendinous, and 5 × 104 dyne/cm2 for dog abdominal muscle).[28] From the above relationship of the bulk modulus β to acoustic impedance (z = [βρ]1/2 ) and velocity (c = [β/ρ]1/2 ), it is easily realized that tissue highly distributed with collagen may have sharp changes in z and c, which would produce high inhomogeneity in acoustic properties, thereby leading to a tissue with high scattering. An example of this is the highly collagenous tissue in the submucosa of the intestine. The submucosa produces much higher echogenicity than the muscle in the wall. [29] However, measurements of the modulus of fixed bovine flexor tendon at 5 MHz have revealed values of 45.1 × 109 dyne/cm2 in the direction of fiber orientation and 30.8 × 109 dyne/cm2 perpendicular to the fibers,[30] which were found to be only factors of 1.8 and 1.3 greater than the values in fixed human myocardium, with the fibers respectively oriented. One would expect higher ratios based on the low-frequency measurements of bulk modulus and the fact that only 1% (wet weight) of the myocardium is collagen, whereas 30% (wet weight) of the tendon is collagen. [30] The high modulus of the myocardium may be due in part to the fixation process, but it may also explain why the myocardium is both echogenic and attenuative. A high degree of scattering can produce a high attenuation coefficient, because attenuation is composed of both scattering and absorption. Goss and O'Brien[31] in 1979, using a 100-MHz acoustic microscope, measured the velocity of propagation in mouse tail tendons and found an average value of 1733 ± 56 m per second; this is in the range that Hoffmeister et al [30] found in 1994 for cross-fiber tendon velocity. Two other specific tissues, bone and lung tissue, also affect transcutaneous cardiac imaging. The attenuation of lung tissue has been found to vary with the degree of inflation,[32] [33] [34] and of course it is highly attenuative even with low inflation (see Table 9-2) . Both velocity and attenuation have been found to increase with increasing mineral content in bone.[35]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 8
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Scattering One of the most important events in ultrasound interrogation is the scattering of the propagating energy from its initial pathway as it encounters various structures. This event is important for several reasons, but foremost is that the scattered energy is detected in medical ultrasound imaging. Clearly, the more a region tends to scatter ultrasound, the more hyperechoic it is (all other things being equal). Therefore, understanding scattering is important in understanding what is actually measured, as well as in estimating what can be measured in a particular situation. The complexity of scattering is directly related to the complexity of the structure being investigated. Some of the initial understanding was provided by Lord Rayleigh[36] as early as 1877, but today research in scattering continues. Considerable insight into scattering can be obtained by first considering scattering from a single particle in a homogenous medium. As the mechanical properties of the particle with respect to the surrounding medium vary, so does the scattering. Further, the size of the particle with respect to the wavelength of the interrogating sound is very important. When the size of the particle is very large with respect to the wavelength, the particle reflects like a smooth surface. A second useful area for deliberation is scattering from a surface both smooth and rough, but this is not discussed here. Third, it is useful to consider tissue as a structure in which (1) the velocity of propagation varies some fractional amount with distance, and (2) each point in the tissue has identical acoustic properties over only a finite length (a correlation length). These three cases are simplifications of what occurs at all sites in the body, but they provide helpful insight for understanding the more complex situations. Some useful terms have grown out of the radar and sonar literature and have been applied to medical ultrasound in order to provide quantitative descriptions: Scattering cross σs = Ps /Ii with units of area (e.g., section
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Differential scattering cross section
Pagina 2 di 8
σd (theta) = R2 Is (theta)/Ii
Backscattering cross σ = R2 I (180°)/I b s i section Backscattering coefficient
ηb = R2 Is (180°)/Ii V
cm2 ); with units of area per solid angle; with units of area per solid angle (e.g., cm2 /Sr); and with units of area per volume-solid angle or 1/length-solid angle (e.g., cm-1 Sr-1 )
where Ii is the ultrasound intensity incident on the particle; Ps is the average
power scattered from the particle; R is the radial distance from the particle to an observation point (where R is considered to be in the far field of the scatter); theta is the angle between the direction the sound is scattered and the direction the sound is propagating; Is (180 degrees) is the scattered intensity in the back direction (i.e., theta = 180 degrees); and V is a unit volume (e.g., cm3 ).
Each of these terms has a physical meaning. The scattering cross section σs describes the amount of cross-sectional area needed in the incident beam to contain as much power as is scattered by the object (i.e., power = area × intensity). The differential scattering cross section relates the incident intensity to the intensity scattered per unit solid angle in the direction described by the angle theta. The backscattering cross section relates the incident intensity to that scattered opposite to the direction the beam is 191
propagating (i.e., back, theta = 180 degrees). Most ultrasound instruments detect only backscattered signals, not those scattered at other angles. The radial distance R appears in the last two equations because we are relating two intensity terms, and we assume the scattered intensity is uniform over some small solid angle (consistent with the far-field approximation of an aperture). There is a directional or angular factor in the equations because scattering in a particular direction (e.g., the back direction) may be different from scattering in other directions; therefore, the units are area per solid
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 8
angle, where the solid angle is defined in the units of steradians (Sr). Finally, these first two terms have worked well in radar and sonar, in which there are usually single objects in a homogenous medium producing the scattering. However, when one tries to apply these terms to tissue, a rather nonhomogeneous medium, the term backscattering coefficient ηb was
developed. This term relates the back directional scattering cross section σb to a volume or region rather than a single particle; hence ηb = σb per unit
volume, which takes on the expression related to Is (180 degrees)/Ii with the units of 1/length-solid angle (e.g., cm-1 Sr-1 ). Scattering from a Single Particle Scattering from a small fixed sphere in a fluid was first studied by Rayleigh. Small was defined as a sphere with a radius a where the circumference of the sphere, 2πa, divided by the wavelength λ is much less than 1 (i.e., ka = 2πa/λ <<1). In this equation, k is the wave constant = 2πf/c; f is the frequency of the wave; and c is the velocity of propagation. In the Rayleigh range, the differential scattering cross section has been shown for elastic spheres to be given by σd = 0.11 k4 a6 [{(κe + κ)/κ} + {3(ρe + ρ)/(2ρe + ρ)}cos (theta)]2 where, respectively, κ and ρ are the compressibility and density in the fluid, κe and ρe are the compressibility and density in the sphere, and theta is the
angle between the direction of the incident ultrasound energy and the direction of the scattered intensity, which for backscattering is 180 degrees. The red blood cell with a radius of about 4 µ is an example of a particle that is small compared with the wavelength for frequencies below 61 MHz (ka 1 at that frequency) and therefore falls into the Rayleigh scattering region. Therefore, the red blood cell can be approximated as an elastic sphere, and the equation for the scattering cross section in the Rayleigh region for elastic spheres can be applied in the back direction. The compressibility for plasma and a blood cell,[37] respectively, are κ and κe = 40.9 and 34.1 × 10−−12 cm2 /dyne, and the density ρ and ρe = 1.021 and
1.092 g/cm3 . Further, for backscattering, because cos (180 degrees) = −1, then σb = 6 × 10−−3 k4 a6 and k = 2πf/c (where f is the frequency and c is the velocity of propagation), the backscattering cross section is proportional to
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 8
the fourth power of the frequency and the sixth power of the radius. Therefore, the scattering of blood is very dependent on frequency. The ratio of the backscattering cross section to the geometric cross section of the sphere (area of a circle of radius a) is given as σ/πa2 = 2.8(ka)4 This normalized relationship is plotted in Figure 9-7 on the left side of the graph. When ka → 1 there is often a resonance effect in which σ/πa2 oscillates above and below 1 as ka approaches, equals, and becomes greater than 1. For large scatters, the values of ka > 1, the value of σ/πa2 → 1 (if the sphere is infinitely stiff); that is, the scattering cross section becomes equal to the geometric cross section. Therefore, when ka << 1, the surface of the sphere appears as a flat surface with respect to wavelength, and the scattering becomes the same as reflection from a flat surface. For spheres with other values of compressibility, but large enough so the duration of the burst of ultrasound is over before the wave passes from the front of the particle to the back, σ/πa2 → [(z2 − z1 )/(z1 + z2 )]2 , where z1 is the acoustic impedance in the fluid media and z2 is the impedance of the particle. This
term is essentially the intensity reflection coefficient for an interface between two layers.[4] Therefore, there are three regions:
1. Rayleigh region, ka << 1, where σ/πa2 is proportional to the fourth power of frequency; that is, σ/πa2 = 2.8 (ka4 ) 2. Resonance region, ka 1, where σ/πa2 oscillates 3. Large scatter region, ka > 1, where σ/πa2 → the intensity reflection coefficient; further, when ka << 1, the scatter is so large it acts like a surface When ka 1 backscattering resonates, and the angular scattering around the sphere varies and is no longer uniform or isotropic. A particle that is a gas bubble in fluid is interesting for Figure 9-7 Scattering from a sphere in three regions of size with respect to wavelength. See text for discussion.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 8
192
a number of medical reasons (e.g., air emboli and/or ultrasound contrast agents). The isotropic (scattering in all directions equally) scattering cross section equation for a gas bubble in water is given by σs = 4πa2 /{[(fr /f)2 − 1]2 + (f/fr )2 δ2 } where f is frequency of sound, fr is bubble resonance
frequency, and δ is the damping coefficient for the bubble in the fluid.[37] This damping coefficient is related to the thermal properties of gas and fluid, the damping owing to scattering, and the viscosity of the fluid.[38] A value of δ = 0.15 is typical for air in water at 1 MHz. A plot of σs /πa2 , the ratio of scattering to the geometric cross section of a spherical bubble, is shown in Figure 9-8 , and the bubble size needed for resonating at various frequencies is shown in Figure 9-9 . Scattering from Multiple Particles When scatters are spaced in a medium at an adequate distance from each other, then the overall scattering cross section per unit volume (i.e., scattering coefficient) is given by the sum of the scattering cross sections of all the particles in the volume. If all scatters have the same scattering cross section, the number of scatters in the volume times the scattering cross section gives the scattering coefficient. However, when the scatters are located close together, the incident intensity on each scatter may be different because of shadowing from other scatters and/or intensity scattered onto it from other scatters. Further, the scattering arriving at some distant point from each scatter may also be different because of the effect just mentioned, and the scattering pathway from each particle may be altered by other particles in the way. When the particles are close enough for this action, multiple scattering effects occur. Shung et al[39] have studied this Figure 9-8 Isotropic scattering from an air bubble in blood. The vertical axis is the normalized scattering cross section. It is normalized by dividing the scattering cross section by the geometric cross section of the air bubble. The horizontal axis (f/fr ) is the ratio of the ultrasound frequency to the frequency at which the bubble will resonate.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 8
Figure 9-9 Approximate air bubble size at which resonance will occur for various frequencies in blood at body temperature.
effect with respect to scattering from blood at various hematocrits (e.g., porcine blood in laminar flow). Clearly, the higher the hematocrit, the greater the density of blood cells in a unit volume, and one would expect that scattering would linearly increase with the hematocrit if there were no multiple scattering effects. Yuan and Shung[40] described the observed findings with the following equation in terms of the backscattering coefficient: ηb = [σb Wo (1 − Wo )4 ] / [V(1 + 2Wo )2 ] where Wo is the hematocrit expressed as a fraction, V is the volume being studied, and σb is the backscattering cross section from a single cell. This
equation provides an excellent fit to the data in the 1993 report of Shung et al,[39] in which σb = 2.17 × 10−2 cm2 , V = 68 cm3 , and frequency = 7.5
MHz. The results are plotted in Figure 9-10 . The backscattering coefficient increases approximately linearly with hematocrit to a value of about 8%, then the rate of increase decreases until the scattering coefficient reaches a maximum at 13%; thereafter, it decreases with higher values of the hematocrit. When scatters are located closely together, the scattering is less than expected (based on a linear increase with the number of particles). Another interesting finding with blood is that the backscattering coefficient increases as the velocity of the blood decreases. For example, scattering from venous blood is greater than that from arterial blood, which is thought to be due to red blood cells clumping together at slower flow velocities, whereas at higher velocities the fluid shear tends to separate them. Considering that the backscattering cross section in the Rayleigh region is related to the sixth power of the radius of the scatter, clumping could increase the size of each scatter considerably, thereby increasing the scattering amplitude greatly because of this sixth power effect. This may be much more dominant than the fact that the number of individual scatters would 193
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 8
Figure 9-10 The calculated backscattering coefficient for porcine blood in laminar flow for various hematocrit values. (Data calculated from an equation given by Yuan YW, Shung KK: J Acoust Soc Am 1988;84:52– 58; Data from Shung KK, Kuo IY, Cloutier G: Ultrasonic scattering properties of blood. In Roelandt H, Gussenhoven EJ, Bom N (eds): Intravascular Ultrasound. Boston, Kluwer Academic, 1993, pp 119–139.)
be reduced. In fact, reduction may also reduce some of the multiple scattering effect for normal hematocrits of 45%, thereby increasing scattering. The effect would be somewhat like moving to the left from 45% in Figure 9-10 . Because of this increased scattering, blood speckle movement can be observed with the higher-quality B-mode imaging equipment in venous blood but generally not in arterial blood. Finally, stagnant but unclotted blood becomes hyperechoic quickly after cell motion stops. However, on stirring it the blood becomes hypoechoic until the motion stops. Backscattering from Tissue Certain types of tissue, in some ways, acoustically can be considered to be a collection of scattering particles embedded in an acoustic conducting medium. A more meaningful model has been to consider the variation of the velocity of propagation through the tissue, and a term called the correlation length of the structure.[41] The average velocity variation µc is (<∆c>2 /∆c2 )1/2 , where c is the velocity of propagation and <∆c> is the time average change in the velocity as it propagates through a region of tissue. The maximal correlation length b is an expression of the spatial distance over which the acoustic properties of a region remain correlated (based on autocorrelation) with some initial starting point in the tissue. Basically, the acoustic properties are the same for a distance of about b from the starting point. For a region of tissue there is a distribution of correlation lengths. If one assumes a uniform distribution of correlation lengths in the tissue from zero to some maximal value bm , the following expression describes the backscattering coefficient for such tissue[41]
ηd = (3µ2 k/4π)[tan−1 (kbm ) + (1/9)tan−1 (3kbm ) − kbm /(1 + k2 bm 2 ) −
kbm /3(1 + 9k2 bm 2 )]
where k is the wave constant discussed earlier. The following constants
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 8
were found to fit scattering data from dog heart muscle: the percentage root mean square of velocity variation µ = 4.94 and bm = 0.17 mm.[42] Applying
this equation and constant for various values of frequency produces the graph shown in Figure 9-11 . This has been compared over the frequency range of 3 to 7 MHz to measurements and was found to provide a good fit.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/75.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 7
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Tissue Characterization In general terms, ultrasound tissue characterization is an effort to use ultrasound to identify certain physiologic or pathologic conditions of tissue, or to try to classify various features or traits in specific regions of tissue that may be of diagnostic value. This identification has usually involved the application of some form of quantitative measurement and therefore goes beyond the usual imaging and Doppler processing and display. The general trend is to develop in vivo methods of measuring various acoustic parameters such as the velocity of propagation, acoustic impedance, acoustic attenuation, and scattering amplitude, then to apply the methods to normal and diseased tissue. This endeavor has a history starting in the 1970s and was spearheaded, in part, by a symposium titled Ultrasonic Tissue Characterization in 1976[43] the symposium has continued annually since. This annual Figure 9-11 Backscattering coefficient versus frequency for scattering from canine heart muscle using the equation given in the text. The kbm values for 30, 14.1, 5, and 2.5 MHz are, respectively, 2.1, 1, 0.35, and 0.18, and they are found to fit data from O'Donnell, Mimbs, and Miller. [42]
194
meeting has been a forum for presenting new areas of research into this broad field. The initial endeavor met with considerable enthusiasm, but when many of the approaches failed to demonstrate clinical use, the approaches lost their support. Some approaches failed because they were too complex to be implemented in a practical manner at the time; others failed because they were never taken to the point of adequate clinical testing; and some failed just because they seemed to provide no
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 7
improvement in the "characterization" of the tissue tested. Many of the complexities are now more easily overcome with today's computing power and improvements in transducers. Nevertheless, these solutions often pose a Catch-22. To be clinically tested they need to be implemented into commercial machines, but the companies are reluctant to implement or explore such methodologies until the clinical demand or market has been demonstrated. Furthermore, the processing involves obtaining or controlling the ultrasound signals at "primitive" levels in the system, not easily performed by people who do not have the technical details of the specific ultrasound machine involved (i.e., nonmembers of the company making the machine). In spite of this problem, and because of the diligence of the investigators involved, some significant progress has been made related to echocardiography. Worthy of note is the application of various measures of myocardium ultrasound backscattering. These measures have been more readily applied to the in vivo case because they are more compatible with standard echocardiography interrogation. However, early work in the 1970s, for example, frequency and angular scattering effects,[44] backscattering coefficients versus frequency,[45] and attenuation measurement,[46] used excised tissue. In vitro work has continued to provide more basic information from which our understanding of the ultrasound tissue interaction has grown. In addition, early in vivo work involving the study of scattering from normal and ischemic hearts[47] helped fuel some of the work that has been widely reported. The term backscattering coefficient as defined earlier has continued and is continuing to be applied as a prominent measure of tissue characterization. Interested readers can find a comprehensive review of cardiac tissue characterization up to 1986 in a chapter provided by Skorton and Collins [48] in Greenleaf's book dedicated to tissue characterization using ultrasound. There are two troublesome problems in quantitative backscatter measurement. Both problems concern obtaining calibrated data related only to the region of interest. The first problem is the way the ultrasound machines are designed. They have been developed to provide the operator with numerous controls to produce the highest quality image. Adjustment of these controls may change the power transmitted, the gain of the amplifiers, the control curves in the time-varying gain, and the signal-togray level conversion (nonlinear compression). Consequently, unless all these controls are always set the same from patient to patient (which they
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 7
rarely are), the amplitude of the echoes at the receiver are very difficult to quantify and compare from patient to patient. Finally, the frequency response and beam patterns of various transducers and instruments tend to be different, so they require calibration. A useful method of calibration has involved applying the transducer to some type of test phantom with a standard reflector (e.g., a large metal sphere) and recording echoes from it to represent reference data for comparison.[48] The more successful methods, in addition to this, have used information from a point in the imaging system where it has not been adjusted in the various manners mentioned earlier. Usually this is early in the instrument when the signals are still in the radio frequency form. Either the signal is tapped off at this point and linearly amplified, and brought out of the machine to a data acquisition system, or a special section in the instrument has been built to process these signals in a way that is needed just for tissue characterization (which is different from that used for image production). The second major problem is that the intervening tissue between the transducer and the site for measurement interferes with the signals in its passage, which poses formidable problems. This interference is in the form of attenuation, which is unknown not only in amplitude but also in its frequency dependence. The variation in the velocity of propagation through this intermediate region also can distort the beam (phase aberration) and affect measurements. Therefore, the most practical method has been comparing (when possible) adjacent regions of tissue of interest (e.g., suspected disease versus normal, blood versus wall, or changes in echoes from the proximal to the distal portion of the region) or comparing the same region at various time points (e.g., the changes during the cardiac cycle). These comparisons produce more relative measurements, but they offer more reliable approaches. Two measurements, spectral analysis and integrated backscatter, have been particularly studied, the latter extensively. Both methods involve making measurements of the radio frequency or uncontaminated rectified radio frequency signals obtained from a region in an image by setting a window of interrogation at a specific location in the tissue. Electronically, this means sampling and measuring the returning echoes during a specific time period. In spectral analysis, the signals are converted from the time domain to the frequency domain by using the Fourier transform, then the converted echoes are normalized by dividing by the amplitude of the similar frequency components acquired from signals from a calibration target. Comparison of the rate that the amplitude of the different
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 7
frequencies changes over the spectrum has provided a relative measure of attenuation with frequency. Integrated backscatter has been more widely employed in cardiology. The method involves operating directly on the time domain signals. All the signals received during the set duration for interrogation are rectified in some way and integrated or added. This result is then normalized by dividing it by the similar measure (e.g., summation) from a reference target. Neither the spectral analysis nor the integrated backscatter approach by itself can compensate for the intervening tissue effect; therefore, these measurements need to be compared in some manner, as mentioned earlier. Comparison to scattering from blood in the cardiac chambers has been considered, and comparison of scattering from the myocardium to the pericardial interface has been successfully employed in diabetic patients.[49] Further, recording and analyzing the variation of 195
the amplitude of the integrated backscatter during the cardiac cycle have been highly useful. In fact, the cyclic variation of integrated backscatter has been found to provide useful diagnostic information. Overall backscatter has been found to be useful in depicting cardiomyopathy, [50] [51] [52] infarcts,[53] [54] [55] ischemia,[56] [57] [58] [59] [60] [61] and stunned myocardium.[62] [63] Infarcts that have become highly collagenous produce high backscatter and are more attenuative. Calcification produces even higher scattering and prominent shadowing beyond the calcification because of the high attenuation of the calcified tissue. The cyclic variation of integrated backscatter during the cardiac cycle has been found by Milunski et al[62] to be about 3.8 dB (0.65) in dogs, with the highest amplitude occurring during the cycle shortly after the QRS complex and minimum at end-systole. When ischemia was produced in these animals (15-minute occlusion),[62] the cyclic variation was reduced to 1.7 dB and wall thickening was reduced from 37% to 17%. Within 20 minutes of reperfusion, cyclic variation had recovered to baseline, whereas wall thickening only recovered to 23% in 2 hours. Based on the wall-thickening recovery rate and results of other occlusion experiments,[64] [65] the tissue was believed to be "stunned" and would have nearly recovered in 48 hours. The findings indicated that the recovery of the cyclic variation of integrated backscatter precedes the recovery of wall thickening after the myocardium has received an ischemia insult and then been reperfused. In a second report from the same group,[63] cyclic variations in integrated backscatter were studied in 21 patients within 24 hours of having symptoms, indicating acute
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 7
myocardial infarction. Measurements from infarcted and normal regions of the heart were made. The average magnitudes of the cyclic variations were 0.8 dB in the infarct areas and 4.8 dB in normal areas. In 15 patients patency was later determined by coronary arteriography, then the patients were restudied with ultrasound within an average of 7.1 days after arteriography. In patients in which patency was documented, cyclic variation had increased from an average of 1.3 to 2.5 dB, whereas in patients without patency the cyclic variations had no recovery. Neither group had shown any significant wall-thickening recovery based on echocardiography at the time of the studies. This second study[63] tended to confirm the findings in animals.[62] In the Milunski et al studies,[62] [63] the normal variation found in the humans was about 1 dB greater than that in the dogs. Perhaps this result reflects a difference between dogs and humans, but it also may reflect the vigorous compensatory contractions that can occur in normal regions of the heart when a portion of the heart is infarcted, in contrast to when the entire heart is normal. We have observed this compensation effect using a regional ejection fraction measure when 3D imaging infarcted hearts. [66] Therefore, care should be taken when using other regions of diseased hearts for comparison. Further, numerous studies of cyclic variation by various investigators around the world have been sparked by the earlier and other findings. Not all investigations have found the same results, perhaps owing in part to differences in the study methods. Finally, considerable interest has been stimulated in trying to understand what exactly the ultrasound scattering mechanism is that is responsible for these findings; a few of these studies are discussed further later. Two related studies provide some insight into why there may be cyclic variations during the cardiac cycle. The orientation of myocardial fibers changes from the epicardium to the endocardium.[67] The scattering from the myocardium has been modeled as cylinder-shaped scatters, centered randomly, but angularly oriented and embedded in homogeneous medium. [68] The model demonstrated anisotropic backscattering, which varied with the orientation of the ultrasound impingement to the angle of alignment of the cylinders (maximal scattering when perpendicular), and their simulations could be fit to angular integrated backscattering measurements of others.[69] More recently, Rose et al[70] used ellipsoid shells with acoustic properties of collagen as elementary scatters in a homogeneous medium with the average properties of myocardium as a scattering model. The implications were that the myocytes are surrounded by collagen that forms
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 7
the major scattering surface, whereas the rest of the tissue is fairly homogeneous. Based on the understanding of the dominant role that collagen plays in ultrasound scattering and the geometric arrangement of the collagen matrix of the myocardium,[71] this finding is reasonable. It also may explain why the myocardium is so echogenic. Again the model could be found to fit angular measurement data of others.[69] Therefore, as the myocytes shorten and expand with contraction, their orientation also may change with contraction, and this may produce a change in the backscattering. It doesn't, however, exactly explain why stunned but perfused myocardium might have cyclic variation whereas infarcted myocardium has little. Further studies of normal, stunned, and infarcted dog hearts were conducted with 5-MHz backscattering and 100-MHz scanning laser acoustic microscope measurements.[72] Ultrasound measurements were compared with myocardial water, lipid, and protein content measurements. The average attenuation at 100 MHz was significantly greater in normal (179 dB/cm) than in stunned (136 dB/cm) and infarcted (136 dB/cm) myocardium, and the velocity of propagation was significantly higher in normal and stunned myocardium (1597 and 1600 m per second, respectively) than in infarcted (1575 m per second) myocardium. The 5MHz backscatter was increased in the infarcted (-42.5 dB) compared with the normal and stunned (-47 dB) regions. These changes are interesting when compared with the tissue findings of significantly increased water content (81%) in infarcted regions, whereas the water content in normal and stunned regions is 73%. The protein content is lower in the infarcted regions (18.5%) than in the normal regions (21.5%), and an increase in lipid content is found in stunned (8.5%) compared with normal (5.5%) and infarcted (0.8%) regions. Perhaps most interesting is the increase in water content in the infarct areas. The reduction in attenuation and speed is consistent with the increase in water, based on the earlier discussions. Loss of intermyocyte collagen struts has been found with infarction, and this loss correlated with infarct expansion. [73] If backscattering from the myocardium is operating in the region of multiple scattering, an increase in spacing 196
between scatters may decrease the canceling effect of multiple scattering and thus increase the backscattered signal, but this is only speculation. The presence of fluid can increase the echogenicity in other muscle tissue, but it
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 7
depends on the way the fluid collects.[74] Once again, insight has been gained into myocardium backscattering, but why cyclic variation may recover in stunned myocardium but not in infarcted myocardium remains a mystery.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/76.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 4
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Harmonic Imaging The new imaging formats referred to generally as harmonic imaging have improved the quality of images considerably. Interestingly, harmonic imaging has come about by serendipity. In trying to find methods of enhancing echo contrast images, researchers developed harmonic imaging and more recently pulse inversion imaging. It has been found by accident that these techniques improve images without the need to inject echo contrast. In seeking a reason for this improvement, we have learned that some of the former ways of thinking about ultrasound propagation imaging have not been entirely correct. The generally accepted concept was that ultrasound waves at acoustic levels used in diagnostics propagate in a completely linear manner. "Linear" in this setting implies that if one transmits at a certain frequency, the received energy returns only at the same frequency as that transmitted. One exception is Doppler shifts that might occur because of tissue or blood movement. However, Doppler frequency shifts in the human body are only fractional shifts in frequency from the fundamental, whereas harmonics involves frequencies two, three, or more times higher in frequency than the fundamental. In order to understand these frequency shifts, it is helpful to review what happens in a sound wave. An acoustic wave propagates away from an acoustic source of vibrating particles because particles adjacent to them must respond to the force by applying a countering force (Newton's third law of motion). In turn, these new stressed particles also must apply force to particles more distal but adjacent to them. Therefore, such a disturbance of vibrating particles couples through the media, particle by particle, continuing to attempt to satisfy the condition that in equilibrium the sum of all forces must be zero. This dynamic coupling action constitutes the propagation of a wave. The speed at which it propagates is related to the mass of the particles (i.e., the density of the media) and its "springlike characteristics" (i.e., bulk modulus). Further, the greater the velocity at which the particles originally
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 4
vibrate, the greater the acoustic pressure in that region and the higher the intensity. As the wave propagates, one can consider the net velocity at which the particles move. This net velocity is the sum of both the particle velocity from the vibration and the speed at which the wave propagates. In a standard longitudinal wave, the particles vibrate along an axis that is in the same orientation as wave propagation. However, during the positive pressure (compressional part of the wave) the particles move in the same direction as the wave is propagating, but during the negative pressure (rarefactional part of the wave) they move in the opposite direction. The net effect is that the particles move slower during the rarefactional portion of the wave because the particle motion subtracts from the speed of propagation. In the compressional segment of the wave, particle velocity adds to the speed of propagation. These effects accumulate as the wave propagates along and have the tendency to distort a sine wave, with the compressional part becoming sharp at the front of the wave and the rarefactional part becoming retarded. The overall appearance tends toward a sawtooth-shaped wave rather than its original sinusoidal form. This distorted wave can be described as a wave composed of a certain amplitude of the fundamental frequency (f0 ) and various levels of higher harmonics (2f0 , 3f0 , 4f0 , and so on). The closer the distortion approaches the shape of a sawtooth wave, the higher the amplitude of the harmonics. On the other hand, if the wave remains a sine wave, there are no harmonics. A final key point is that the intensity or amplitude of the acoustic pressure is important. The higher the amplitude, the more rapid or closer to the transducer this nonlinear distortion occurs. This understanding of nonlinear propagation has principally been derived from propagation in water,[75] in which the attenuation is low. There have been no reports on experimental measurements in actual tissue (of which the author is aware); however, there have been several recent reports of nonlinear modeling, including tissue equivalent attenuation.[76] [77] [78] A major effect of tissue according to these models is that the increased attenuation with frequency tends to nullify the generation and propagation of higher harmonics to some extent. Therefore, the generation of sharp sawtooth waves appears unlikely. However, the wave can still be rich with harmonics as verified by the fact that harmonic imaging actually works. Considering earlier discussions, the reasons why images are now better are explained. First, the generation of harmonics requires the fundamental
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 4
frequency to propagate some distance. This indicates that the various aberrations and possible reverberation effects that occur at the skin, fat, and muscle layers of the chest wall do not affect the harmonic waves because they develop deeper in the tissue. Therefore, the detrimental effects on the conventional image that occur as the result of aberration to the beam[79] owing to the chest wall is avoided, at least for the transmission portion of a transceiving process. Second, the higher the amplitude, the greater the tendency to produce these harmonics more rapidly and more extensively. Therefore, the generation of harmonics occurs more rapidly in the center of the beam of the wave at the fundamental frequency because the intensity there is higher. This action causes the harmonic beam to be narrower. As mentioned earlier in the chapter, for the same size aperture a higher frequency also produces a narrower beam pattern. The net result of these effects is that higher harmonics produces a beam pattern that is narrower than the beam formed at the fundamental frequency. This narrower beam leads to a higher resolution image. Finally, as indicated in Figure 9-7 , if the scatters fall in the Rayleigh region, the backscattering increases for the higher harmonics. Therefore, one anticipates increased backscattering from cardiac muscle (see Fig. 9-11) for 197
the higher harmonics. Similarly, backscattering from a nonperpendicular angle of encounter of the acoustic beam with a semirough scattering boundary may produce higher backscatter at the higher frequencies. These two effects also are most likely contributing factors to the improved images of the endocardium obtained by harmonic imaging. Having described the mechanisms for image improvement that harmonic imaging provides, there are still some design aspects of a conventional ultrasound imaging system that have to be overcome to obtain these advantages. These aspects include features that are needed for high range resolution. A wide bandwidth system is required to ensure the transmission and reception of very-short-duration excitation bursts. The shorter the duration, the wider the frequency spectral content of the excitation signal and the wider the bandwidth needed to transceive it. A wide bandwidth excitation signal also produces wide bandwidth harmonics. The difficulty arises because the lower frequency components of the harmonics tend to overlap into the frequency range needed for the higher frequency components of the fundamental excitation signal. This action degrades the advantage of the harmonic signals. Therefore, to receive only harmonics,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 4
special designs are needed. Careful shaping of the excitation signal and filtering of the received signal have been successfully employed.[80] An alternative is the use of pulse inversion methods,[76] which appear to automatically suppress the fundamental excitation signal and tend to allow recovery of only the harmonic. Although the advantages of harmonic imaging are becoming well recognized in echocardiography laboratories, there are limited formal studies of the advantages of harmonic imaging. Reports from symposia have provided some documentation. Improvements were found in visualization of the aortic valve in 70% of 40 patients with harmonic imaging, whereas visualization was possible in only 35% of the patients with normal imaging.[81] Left ventricular thrombi was looked for in 93 patients with myocardial infarction and only 7 were found with use of normal imaging, but two additional ones were found with use of harmonic imaging. [82] Harmonic imaging is now routinely used in the echocardiography laboratory at the University of Washington Medical Center because of the advantageous experience with its use. The only shortcoming our cardiac sonographers report is that valve leaflets tend to appear thicker with harmonic imaging than with normal imaging. This effect most likely arises from an artifact produced in the processing system, which is caused by the rapid movement of the valve leaflets. However, a more in-depth study is needed to clarify this observation and what the artifact mechanism actually is. Of final note, harmonic imaging is being found to provide better images in numerous other areas beyond echocardiography. This method is indeed an advancement in ultrasound imaging.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/77.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Summary The physics of ultrasound in terms of beam patterns, propagation, attenuation, and scattering is important in echocardiography. Some of the important aspects of these factors have been discussed in this chapter. This is by no means an exhaustive review, but it may stimulate the reader to more reading in this area and may provide some assistance in understanding this sometimes nonclinical literature. The spatial resolution, which consists of range resolution (related to the pulse duration), lateral resolution (related to the lateral beam width), and elevation resolution (related to the elevation beam width), is very important in the accuracy of length, area, and volume measurements. These factors are particularly important when the ultrasound beam impinges on boundaries obliquely. Evolving technical improvements in imaging, which improve resolution and reduce aberration effects of tissue (e.g., harmonic imaging), will provide more accuracy in quantitative measurement by reducing the effects that have been discussed. Continued technical improvement and discovery is certainly a hope for the future.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/79.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 4
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Measurement Errors Numerous errors can result when quantitative measurements are made using ultrasound. One area of difficulty is the variation in the speed of sound. Generally, most instruments use a value of 1540 m per second for the average speed of sound in tissue at 37°C. The calibration markings on the screen for distance are based on this value. Further, for phase arrays the delays used in the instrument to steer the beam to produce the scanning sector also use this value. As discussed earlier, the speed in different tissues varies to some extent. For example, if the distance across the aorta is measured as 2 cm based on the calibration on the screen using 1540 cm per second whereas the actual speed of sound in blood is 1579 cm per second, there would be an error of -2.5%. This is an error in making a onedimensional measure along the direction the ultrasound propagates. If the speed of sound is different from 1540 m per second, the angle of the phased array may be different, so lateral measurements in the image also can suffer some error because of speed-of-sound differences. Circular structures can become elliptic if there is a great difference in the speed of sound. Perhaps bigger mistakes can be made when investigators are performing in vitro studies using water or excised tissue at room temperature. The problem with water can be avoided by using a salinity of 4.62% (see Table 9-1) , in which the speed of sound is 1540 m per second. The speed of sound in excised, fixed tissue at room temperature also varies from body temperature speeds. Although the speed-of-sound errors can be quite important in many situations, the larger errors often may occur because the beam patterns are not ideal (i.e., infinitely narrow and pencil-like) and the duration of the interrogation pulse is not infinitely short. The earlier discussion explains imperfections of beam patterns, and later I discuss how these imperfections can cause errors in area and volume measurements. First, some of the errors that can occur from a finite duration of the interrogation pulse are illustrated in Figure 9-12 . The beam width is assumed to be very narrow.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 4
Two situations (a short and a long pulse) are shown in which the beam passes from a hypoechoic Figure 9-12 Diagram illustrating how the range resolution (related to the length of the interrogating pulse) can increase thickness of the ultrasound appearance of a hyperechoic layer. See text for explanation.
198
to a hyperechoic layer, then back to a hypoechoic layer, again through a hyperechoic layer, and back to a hypoechoic layer. The two types of pulse are shown at different positions along the structure. They are shown just as they are entering the hyperechoic layers and just after the trailing edge of the pulse exits the hyperechoic layers. The resulting A-mode lines are illustrated. The key points here are that the beginning of the echo starts at the leading edge of the pulse, passing from a hypoechoic to a hyperechoic region, but the end of the echoes from the hyperechoic to hypoechoic passage do not end until the trailing edge clears the hyperechoic layer. The two pulse durations, when used for linear scanning of the two layers, then produce images as illustrated. With the long-duration pulse, the hyperechoic layers appear much thicker than they really are and the distance between the layers appears shorter than it really is (compare d2 on the figure with d1). Therefore, the pulse duration (which is of course related to the range resolution) if excessive may result in quite an error in layer thickness measurements. This has been a concern in measuring the layers of intestinal walls in gastroenterology,[83] measuring blood vessel walls, and measuring cardiac wall thickness. This consideration has brought up the topic of leading to leading boundary edge outlining and trailing to leading edge with correction methods.[84] [85] The next consideration is the effects of lateral beam width, which are illustrated in Figure 9-13 for narrow pulses and in Figure 9-14 for long pulses. The transducer is on the left with a beam pattern diverging to the right. Two situations are shown: (1) when the beam encounters boundaries fairly perpendicularly ( see Fig. 9-13A and Fig. 9-14A ) and (2) when the beam encounters boundaries obliquely ( see Fig. 9-13B and Fig. 9-14B ). In Figure 9-13A , the A-line echoes from a tubular structure (perhaps a shortaxis left ventricular view) are illustrated. Echo 1 arises from the proximal wall and echo 2 from the distal wall. Even with a short-duration pulse, echo
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 4
4 is of longer Figure 9-13 Diagram illustrating how a short-duration pulse with a lateral beam pattern that is diverging and has a finite width can affect the measurement of wall thickness. The lateral beam width is related to the lateral resolution of the system. A, Beam tends to encounter the wall fairly perpendicularly. B, Beam encounters the wall at an oblique angle. See text for discussion. Figure 9-14 Diagram illustrating how a long-duration pulse with a lateral beam pattern that is diverging and has a finite width can affect the measurement of wall thickness. The lateral beam width is related to the lateral resolution of the system. A, Beam tends to encounter the wall fairly perpendicularly. B, Beam encounters the wall at an oblique angle. Note the increase in the wall echoes compared with those of Figure 9-13 . See text for a detailed discussion.
duration than echo 2 because a portion of the beam encounters the distal wall earlier than in Figure 9-13A (normal encounter). The effects of the longer pulse are shown in Figure 9-14 . Echoes 1 and 2 are of longer duration than those of echoes 1 and 2 in Figure 9-13A because of the effect illustrated in Figure 9-12 . In addition, echoes 3 and 4 are of longer duration than 3 and 4 in Figure 9-13B . If one is measuring the inside dimension or inside area of a chamber, the oblique encounter with a wide beam reduces the inside dimensions of the structure (compare d2 with d1 in Figure 9-13 ). This effect is even further aggravated by the long pulse (compare d2 in Figure 9-14 with d2 in Figure 9-13 ). This phenomenon can contribute to the underestimation of chamber or vessel area measurements with ultrasound. The final consideration is the effect of the beam width on the elevation direction. In Figure 9-15A a tubular structure is imaged so that the ultrasound imaging plane encounters the wall of the tubular structure perpendicularly. If the lateral beam width is extremely narrow and the pulse is very short, the image that is generated is similar to that illustrated in Figure 9-15C . The geometry of the imaged structure is faithfully reproduced. However, if the imaging plane encounters the wall at an oblique angle, because it has a certain beam width, it in essence images a thick oblique slice through the wall, like the slice illustrated in Figure 915B . Considering that echoes are generated as long as a portion of the beam is cutting tissue, the imaging of the structure shown in Figure 9-15B
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 4
results in an ultrasound image as in Figure 9-15D (i.e., essentially an image with a reduced cross-sectional area of the inner chamber and increased area of the outer contour). In the real imaging situation, the lateral beam width and pulse duration also contaminate the image; therefore, the cross section of the inner cavity is reduced even more and the outer border area increased more than shown in Figure 9-15D . These effects may play important 199
Figure 9-15 Diagram illustrating how the elevation resolution (i.e., a finite beam width in the elevation direction) can affect the ultrasound image obtained from a tubular structure. A, Beam pattern encounters the wall in the elevation direction (direction out of the paper) at a fairly perpendicular angle. B, Beam encounters the wall in the elevation direction at an oblique angle. C, Type of image of the wall structure that is produced with perpendicular encounter as in A. D, Type of image of the wall structure that is produced with an oblique encounter as in B. Note the reduced inside area and enlarged outer area.
roles in causing underestimation of the inner area or volume (such as the volume of the left ventricle) of chambers or vessels. Much of the underestimation reported in the literature when measuring volumes (e.g., with 3D ultrasound) may arise from the oblique encounter with nonperfect beam patterns and pulses. Therefore, by orientating the imaging beam of the probe so that it encounters the organ walls as perpendicularly as possible, the best accuracy can be obtained. The method reported by Gopal et al[86] [87] in making 3D measurements of left ventricular volume is favorable from this viewpoint. It is also possible to correct for some of these artifacts by the way the contours are outlined. Perhaps, in some of the measurements in which underestimation was not reported, the outlining was performed in a manner that placed the border well into the echo boundary of the image. It is therefore very important to understand the various measurement artifacts that can arise and try to design measurement methods to minimize these effects.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/78.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
202
Chapter 10 - Three-Dimensional Echocardiography Approaches and Applications Florence H. Sheehan MD
Two-dimensional echocardiography provides visualization of many structures in the beating heart; however, interpretive skills are needed for the observer to mentally formulate the heart's complex three-dimensional anatomy. In three-dimensional echocardiography, the spatial location and orientation of each two-dimensional image plane is recorded with the image so that information from multiple images can be analyzed jointly. This permits multiplanar image data to be assembled into three-dimensional displays that facilitate the assessment and communication of anatomic relations. The three-dimensional format also enables the quantification of the size, shape, and function of cardiac structures with minimal geometric assumptions, a particular advantage when dealing with disease-distorted anatomy or complex shapes such as the right ventricle. Although threedimensional echocardiography was conceptualized in 1961, most of the advances were made during the past decade after fast and inexpensive computers became more readily available; Belohlavek et al[1] have reviewed the earlier work.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Modes of Three-Dimensional Echocardiography Three-dimensional echocardiography is often equated with volumetric imaging to obtain spatial visualization of cardiac anatomy[2] [3] (Fig. 10-1) . In this mode of three-dimensional echocardiography, spatially dense image data sets are acquired and processed to permit the shape of the structures to be appreciated visually using three-dimensional display formats such as surface rendering, which employs shading to indicate topology. The image data set can be opened at any cut-plane to provide a surgeon's eye view of the heart's interior. The third dimension can also be appreciated using stereoscopy or holography.[4] [5] In the surface modeling mode of three-dimensional echocardiography, the three-dimensional surface of the targeted structure is reconstructed based on tracings of its border from multiple image planes (Fig. 10-2) . All chambers and valves can be reconstructed, as well as intracardiac structures such as the papillary muscles and chordae tendineae for quantitative analysis of size, shape, function, and spatial relationships between structures. Surface modeling is the mode of three-dimensional echocardiography that provides superior accuracy in measuring ventricular volume and mass, and for accurate, reproducible measurement of a variety of cardiac descriptors. Volumetric imaging is primarily used to search visually for structural abnormalities such as congenital defects or deformed valves, although volumetric data sets can also be analyzed to measure volume or a defect's size. In both modes of three-dimensional echocardiography, quantification currently requires manual image analysis. Because both modes of three-dimensional imaging involve 203
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
Figure 10-1 Volumetric imaging provides a realistic, "surgeon's eye" view of the heart. This study is of an in vitro heart imaged in a water bath. AML, anterior mitral leaflet; AoV, aortic valve; LV, left ventricle; LVOT, left ventricular outflow tract; PML, posterior mitral leaflet; RVOT, right ventricular outflow tract. (From Sheehan FH, Wilson DC, Shavelle D, Geiser EA: Echocardiography. In Sonka M, Fitzpatrick JM [eds]: Medical Image Processing and Analysis. Bellingham, Wash., SPIE Press, 2000, pp 609–674.)
the acquisition of image data continuously through the cardiac cycle, it is possible to prepare the data in time-varying format for visual review of the heart's dynamic function or for quantitative analysis of asynchronous events. As for visualization at end-diastole and end-systole, dynamic presentation is easily automated in volumetric mode.[6] For quantitation, however, the border tracing must be repeated at every time point, a daunting prospect until the accuracy and reliability of automated border detection suffices to be used clinically. Figure 10-2 Left ventricular endocardial surface of a normal subject at end-diastole, reconstructed using the piecewise smooth subdivision surface method from freehand transthoracic scanning.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/82.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 8
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Image Acquisition The intended approach to data analysis determines the method for image acquisition. In general, imaging for surface reconstruction uses free hand scanning. In contrast, the tight format required for volumetric imaging has until recently mandated the acquisition of these data sets using a mechanical device at fixed spatial intervals. Because certain methods for surface reconstruction incorporate assumptions concerning the position and orientation of the image planes, the requirements for a particular analysis need to be met during acquisition. Violation of the assumptions introduces error into the analysis.[7] Tracking Systems Knowledge of the position (x, y, z) and orientation (ρ, phi, theta) of the ultrasound transducer permits assembly of the images and their derived data in three-dimensional space. There are a number of methods for tracking the transducer during scanning. These methods can be classified into mechanical, line of sight, and magnetic. Each technology has its own advantages and limitations. The oldest type of mechanical system employs a series of articulated arms with encoders at the joints (Fig. 10-3) . The scanhead is placed at one end of the system and the other end (the base) is rigidly mounted to a reference frame. Reading the encoders provides rotational information about the articulated arms attached to that joint. Knowing the length of the arms and the rotations yields the position and orientation of the transducer with respect to the base. The major limitations to using mechanical arms are bulk and intrusion into the measurement space. It is awkward for the sonographer to manipulate the arms to reach all required positions and orientations. Each degree of freedom in the arm's motion presents a potential source of error.[8]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 8
204
Figure 10-3 Schematic representation of an articulated arm for mechanical tracking of the ultrasound transducer. This arm has 6 degrees of freedom. (From Nikravesh PE, Skorton DJ, Chandran KB, et al: Ultrasonic Imaging 1984;6:48–59.) Figure 10-4 Mechanical tracking permits acquisition of images in parallel planes (A), angulated scans (B and C), or rotational scans (D) from the transesophageal window. (From Flachskampf FA, Franke A, Job FP, et al: Am J Cardiac Imaging 1995;9:141–147.)
205
Another mechanical approach is to rotate or angulate the transducer within a constant location while recording the angle (Fig. 10-4) . Rotational scans are generally performed at the apex around the long axis of the left ventricle but can also be acquired at parasternal, subcostal, suprasternal, or transesophageal windows for volumetric imaging, such as to assess congenital defects.[3] [9] [10] By acquiring a full 180-degree rotation and checking that the first and last images are mirror images, one can be assured that transducer position was maintained during image acquisition. Rotational scanning is the most common acquisition mode for volumetric imaging. Angulating the transducer from a fixed position produces a fanlike are of images and has been successfully performed in the transthoracic parasternal window for the left and right ventricles [11] and in the transesophageal approach.[12] [13] One major disadvantage of rotational and angulated scanning is that not all hearts fit within the image volume circumscribed by the rotated or angulated sector, so that the margins of dilated hearts even in children may be incompletely imaged.[14] If the left ventricle can be visualized completely within a parasternal rotation, experimental studies indicate that the accuracy of volume measurement is greater than with an apical scan, presumably because of the low incidence angle of the ultrasound beam to most of the myocardial wall.[15] A second disadvantage is that poorly visualized structures cannot be recovered by scanning elsewhere, because imaging is limited to one acoustic window. Third, the quality of the images often varies when the transducer is rotated mechanically about a fixed axis; in contrast, freehand scanning permits adjustment of the image plane to obtain optimal image quality.[16] A fourth disadvantage of rotational and angulated scans is the relatively limited
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 8
spatial resolution in the far field where the image planes are more widely separated. For visualization of congenital defects, this problem is handled by centering the axis of rotation over the region of interest. Linear scanning, also called bread-loafing, parallel slicing, or pullback scanning when referring to transesophageal acquisition, generates images in parallel planes (see Fig. 10-4) . The narrow intercostal space limits a transthoracic interrogation of the entire ventricle.[2] However, partial scans still permit specific localized defects to be studied, for example, to examine congenital atrioventricular valve defects or to examine the success of a surgical correction.[17] Complete data sets can occasionally be obtained from the subcostal window.[17] A transesophageal echocardiography system was developed to obtain parallel image planes by straightening the esophagus[18] (Fig. 10-5) . Unfortunately, this maneuver displaces the transducer posteriorly away from the apex.[6] Owing to these acoustic window restrictions, linear scanning is more commonly used in abdominal imaging. Line of sight systems include ultrasonic and optical tracking systems. Ultrasonic tracking systems typically utilize a single sound wave source and three fixed, known sensors[19] [20] (Fig. 10-6) . The speed of sound through air allows the range between the source and sensors to be determined. Triangulation determines position. Multiple sound sources are required to determine orientation. Ultrasonic systems suffer from shadowing, ambient noise, Figure 10-5 Diagram of system for parallel tomographic image acquisition. After the transesophageal echocardiographic probe is positioned posterior to the heart, the carriage is straightened and the transducer is retracted with the use of a stepper motor to obtain closely spaced (1 mm) images. (From Wollschlaeger H, Zeiher AM, Geibel A, et al: Transesophageal echo computer tomography of the heart. In Roelandt JRTC, Sutherland GR, Iliceto S, Linker DT [eds]: Cardiac Ultrasound. London, Churchill Livingstone, 1993, pp 181– 185.)
and interference due to acoustic reflections. The accuracy depends on maintaining constant air temperature, which affects the velocity of sound by about 2% per 10°C. [21] Furthermore, the need to maintain a clear path between transmitter and sensor restricts the sonographer's movement, the device produces unpleasant sounds, and the size of the sensor impedes imaging. Optical systems are not temperature sensitive but do suffer not only from shadowing but also from high cost and inflexibility, the latter due to the need to keep the cameras in a known alignment. Therefore, they have
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 8
not been applied to three-dimensional echocardiography. The magnetic field system generates three orthogonal fields whose strength and direction are detected by a small, light receiver mounted on the transducer [21] [22] [23] (Fig. 10-7) . Only magnetic field systems combine the following: (1) 206
Figure 10-6 Ultrasonographic transducer with three spark gaps (arrowhead) mounted. This configuration provides direct transmission of audible sound toward the localizing array of four microphones. (From Handschumacher MD, Lethor JP, Siu SC, et al: J Am Coll Cardiol 1993;21:743–753. Reprinted with permission from the American College of Cardiology.)
They are able to track the position and orientation of the scanhead during freehand scanning; (2) they allow acquisition of images from randomly oriented image planes; (3) they allow acquisition of images from multiple acoustic windows; and (4) they permit imaging within the body as well as transcutaneously. The disadvantages Figure 10-7 Schematic of three-dimensional echocardiographic image acquisition using a magnetic field system to track the position and orientation of the ultrasonographic transducer. (From Nguyen TV, Bolson EL, Zeppa M, et al: Am J Cardiol 1999;84:208–213. Reprinted with permission from Excerpta Medica Inc.)
are that sources of ferromagnetic interference such as hospital beds must be distanced from the field, and the system's safety for patients with pacemakers or implanted defibrillators is unknown. A novel ultrasonography machine has been developed that is capable of acquiring a pyramidal volume of image 207
Figure 10-8 Schematic of the image set acquired using a matrix array transducer. Demonstrated are two adjustable orthogonal B-scans perpendicular to the transducer and three adjustable C-scans parallel to the face of the transducer. (From Zwas DR, Takuma S, Mullis-Jansson
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 8
S, et al: J Am Soc Echocardiogr 1999;12:285–289.)
data using a two-dimensional array transducer[24] (Fig. 10-8) . Because it obtains the entire image set from one cardiac cycle instead of assembling images acquired over multiple cardiac cycles, this "real-time" system eliminates the assumption, inherent in multiple beat analysis, that all of the component two-dimensional images fall on the same phase of the cardiac cycle and that the function, position, filling, and rhythm of the heart remain constant throughout imaging. The disadvantages are that images are acquired in a single acoustic window, enlarged hearts will not fit within the pyramid, a specialized ultrasonography machine must be purchased, and image quality is poorer than for three-dimensional echocardiography acquired using conventional ultrasonography machines.[25] In addition, the C-scan images, which are short-axis cross-sectional views parallel to the transducer face, have relatively poor lateral resolution. Consequently, volume and mass are underestimated and less accurate than measurements made from the B-scan images.[26] The speed of the three-dimensional acquisition enables scans to be obtained without sedation, even in infants.[27] One system provides real-time tracking of image plane position and orientation in addition to recording these parameters. The current image's location is indicated by a line of intersection with a previously acquired reference or "scout" image[20] (Fig. 10-9) . This technology helps to verify that the short-axis images are being acquired in nonintersecting image planes, a requirement of the polyhedral surface reconstruction method.[28] Use of a tracking system assumes that the patient will remain in the same position throughout imaging. To avoid inadvertent patient movement during image acquisition, it is important to explain the procedure in advance, coach the patient through the phases of the study, and carefully monitor the patient's position. Mechanical tracking also assumes system stability, but probe slippage can occur during a rotation or other manipulation.[29] Therefore, it is prudent to check the image data for possible misregistration, to obtain accurate quantitative analysis. To avoid using tracking systems, some investigators succeeded in producing three-dimensional reconstructions of the left ventricle based on freehand scans within a single acoustic window, by making assumptions concerning the location of the image planes. In one method, the alignment of short-axis contours along a parasternal long-axis contour is deduced from their vertical span and distance from the transducer.[30] Another approach is to assume the spatial location of the image planes based on the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 8
anatomy visible in the image. Fazzalari et al[31] located two orthogonal apical views by scanning anatomically, then rotated the transducer ±45 degrees away to record two additional views, which sufficed to reconstruct the left ventricle. Aakhus et al[32] located three standard apical views anatomically and then assigned to each its theoretical angular rotation. Though ingenious in their utilization of image data to substitute for tracking, these methods' assumption that the image planes were correctly positioned anatomically may not be correct.[33] Imaging Protocol One advantage of three-dimensional compared with two-dimensional echocardiography is that the quantitative analysis does not rely on the ability of the sonographer to acquire images positioned properly in certain standard views relative to the patient's cardiac anatomy. That is, when the reconstructions and measurements are derived from five or more image planes, the locations of those planes are not tightly prescribed. This is because the volume and function measurements are made from surface reconstructions rather than from geometric assumptions. There remain certain minimal requirements, however. The most important are visualization of the apex to define the long-axis length of the left ventricle, and adequate coverage of the ventricle. The protocol for image acquisition is dictated first by the tracking system and then by the reconstruction method. The least flexible are the mechanical systems that acquire a rotational or angulated scan from a fixed position within a single acoustic window or a linear scan from the esophagus. In contrast, articulated arms, acoustic locators, and magnetic field tracking systems permit freehand scanning. Freehand scanning has the potential for allowing the images to be acquired from whatever combination of acoustic windows and views provides optimal image quality for a given subject. The surface reconstruction program may limit this freedom, however. For example, the polyhedral surface reconstruction method requires nonintersecting short-axis views,[34] and the bicubic spline representation was designed for multiple long-axis views.[35] In contrast, the piecewise smooth subdivision surface method and methods based on spherical templates 208
Figure 10-9 Photograph of the line of intersection display. The long-
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 8
axis view (center) is the reference image showing the "line of intersection" display identifying the location of the short-axis images obtained for volume computation. Below and to the sides are the individual short-axis cross sections from apex to base, with endocardial borders outlined. (From Sapin PM, Schroder KM, Gopal AS, et al: J Am Coll Cardiol 1994;24:1054. Reprinted with permission from the American College of Cardiology.)
accept intersecting short- and long-axis views.[36] [37] [38] Since patients vary in the image quality available at the parasternal versus apical windows, having the flexibility to acquire images at either or a combination of windows increases study yield and interpretability. Electrocardiographic and Respiratory Gating Because a three-dimensional image or surface reconstruction is assembled from the data of multiple cardiac cycles, it is necessary to segregate the acquired two-dimensional images according to phase in the cardiac cycle. This may be done manually, by selecting the image frames occurring at end-diastole and end-systole with the aid of the electrocardiogram (ECG), visually assessed chamber area, and closure of the mitral and aortic valves. Technology is available for triggering the acquisition of a cycle of images beginning at the R wave on the ECG in each plane; a volumetric set of image data can thus be accumulated at fractional or temporal intervals through the cardiac cycle. More sophisticated systems also filter out ectopic and premature beats. One should be aware that each ultrasonographic image requires a finite time interval for inscription. Thus, for example, the images showing the peak of the R wave on the ECG trace will cover variably overlapping time intervals around end-diastole, unless triggering is employed. This is unlikely to cause significant error, however, because end-diastole and end-systole are the periods of minimum change in chamber dimension. Analysis of contrast ventriculograms has shown that reducing the frame-rate from 30 to 15 frames per second did not increase error in measuring left ventricular volume or function.[39] On the other hand, reconstructions based on multiple cardiac cycles will be affected by the variable timing if the structure is moving rapidly, for example, a valve leaflet during opening. For fetal imaging in which no ECG is available for gating, retrospective cardiac gating can be performed using Fourier analysis of pixel intensity to reconstruct dynamic volumetric data sets.[40] Patient respiration alters the position of the heart within the chest. In freehand scanning, the patient is coached to breath-hold at end expiration without a Valsalva maneuver. Even heart failure patients are able to
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 8
perform multiple 6-second breath-holds with brief rests in between.[41] In device-driven systems, the image acquisition may be gated to the respiratory cycle, such as by impedance measurement.
MD Consult L.L.C. http://www.mdconsult.com /das/book/view/26070721/1031/83.html/top Bookmark URL:
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 23
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Quantitative Analysis of the Ventricles For quantitative analysis of ventricular size, shape, and function from threedimensional echocardiographic scans, it is necessary to extract the borders of the structure of interest from the images that have been acquired in multiple planes, reconstruct the structure from the borders, and make the desired measurements from the reconstructed surface. The advantage of this approach is that highly accurate representation of structures such as the left or right ventricle can be achieved from which its 209
Figure 10-10 (color plate.) System for image analysis. The twodimensional images are reviewed (right), and the borders of the target organ and associated anatomic landmarks are traced. Using position and orientation information from the tracking system, the x and y coordinates of each border are transformed into x, y, and z coordinates for display in a three-dimensional window (left) in which image and border registration can be verified. Here the red and green borders are traced from the left ventricular endocardium and epicardium, the blue and violet from the right ventricle, and the spheres from valve orifices, ventricular apices, and other anatomic landmarks. (From Sheehan FH, Bolson EL, McDonald JA, et al: Comput Cardiol 1998;25:649– 652. Copyright © 1998 IEEE.)
dimensions, shape, and function can be measured directly without geometric assumptions. The disadvantage is the labor required to trace the borders. Methods are being devised to alleviate the labor of tracing by automatically detecting heart borders from the images (see Chapter 7) . Also, a rapid analysis can be made from a small number of images by sacrificing some of the accuracy or information content (see "Measurement of Volume"). Border Tracing
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 23
Human variability in border tracing has a greater impact on the accuracy and variability of quantitative analysis than error in image plane tracking or image timing relative to the ECG.[7] However, the multiplanar nature of three-dimensional echocardiography makes it possible to review tracings in their spatial as well as their temporal context. That is, border definition can be assisted not only by playing a cardiac cycle of images to track motion but also by using image information from adjacent or intersecting planes, or both, to compensate for poor image quality.[36] Another advantage of threedimensional imaging is the ability of some surfacing algorithms to handle partial borders rather than requiring a complete contour in each image plane.[36] [42] The missing information in one plane is provided in an intersecting plane or interpolated by the surfacing algorithm from nearby border data. A recommended design feature in the tracing software is handling the border as an overlay rather than replacing pixels in the image. [42] This allows the border display to be turned off while the original image is reviewed and then on again to verify that the tracer still agrees with the border location. A three-dimensional display format for reviewing traced borders facilitates the identification of discrepant borders (Fig. 10-10) . Based on their frequency and location, it is then easy to determine whether a single image was misinterpreted or a set of images was misregistered, such as due to patient movement.[42] The technological tool that will have the greatest impact on bringing threedimensional echocardiography into clinical practice is, of course, automated border detection. Numerous studies have already been performed to solve this problem, but none has yet succeeded. Current automation algorithms are reproducible but not accurate. For example, performing three-dimensional echocardiography with acoustic quantification by online integrated backscatter analysis produces smaller endocardial contours and volumes than by manual tracing.[43] Identification of the endocardial and epicardial contours can be aided using myocardial contrast enhancement.[44] Greater accuracy as well as reproducibility in measuring myocardial mass has been obtained in animal studies. It is important to employ a long-lasting contrast agent that persists into the myocardial phase to avoid attenuation from the chamber opacification and to obtain a time window long enough for the threedimensional echocardiographic scan. Doppler myocardial imaging can increase the yield and accuracy of three-
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 23
dimensional echocardiography by using the frequency shift of the returning ultrasound signal in addition to its amplitude. Because the frequency shift is relatively independent of attenuation by chest wall structures, 210
Doppler myocardial imaging provides more complete endocardial boundary detection (80% to 85%) than gray scale images (67% to 71%; P < .05).[45] Surface Reconstruction Many methods have been developed for reconstructing the ventricular endocardial and epicardial surface from traced borders (Table 10-1) . The methods vary in (1) the assumptions or constraints placed on the input data, (2) geometric manipulations inherent in the reconstruction model, and (3) fidelity to cardiac anatomy. Given a series of ventricular contours in parallel planes, it is easy to extrapolate between the contours to produce an enclosed surface if desired for visualization. Such surfaces take a simple form with a single opening at the valve plane if produced from short-axis images alone, since long-axis views are needed to define both valves. Another approach for images acquired in an apical rotational scan is to intersect the traced borders with a series of parallel planes perpendicular to the long axis. The points where each plane intersects the traced borders are connected into a polygon or fitted to produce a curved contour[35] [46] [47] (Fig. 10-11) . Similar surfacing can be performed even if the images are not apical; for example, parallel planes can be intersected with borders from randomly oriented views.[48] The advantage here is the ability to utilize whatever combination of views provided optimal interrogation in a given patient. Instead of intersecting a set of traced borders with parallel planes, the borders can be intersected with a set of rotationally related planes to define the ventricular surface.[19] Borders traced from an angulated scan lend themselves to reconstruction using a cylindrical coordinate system.[11] The contour's area in each pair of adjacent image planes and the plane's angle of tilt are used to compute a wedge volume; the sum over all wedges is the chamber volume. It is computationally simpler to connect the points of intersection in each plane to form a polygon instead of fitting a curve to them,[49] but one risks underestimation of slice area and ventricular volume because, for example,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 23
the area of a dodecahedron is 4.5% less than the area of the circle circumscribing it.[7] A comparison of 12-, 24-, 48-, and 96-sided polygons revealed that 48 sides provides accurate representation of the shape and area of borders traced from photographs of short-axis slices of excised hearts.[50] The polyhedral surface reconstruction method operates on borders traced from short-axis images. Each traced border is divided into 180 points, and corresponding points on adjacent borders are connected to form a triangular tiled surface (Fig. 10-12) .[51] To enable the connections, the input image planes need not be parallel but must not intersect each other within the body of the ventricle. To check the short-axis images being acquired, Gopal et al initially record one or two parasternal long-axis images on which they display the locations of the short-axis images as lines of intersection. [20] The left ventricle is reconstructed from about eight or nine contours; the outflow tract is not delineated. This method has been Figure 10-11 Bicubic spine surface reconstruction. A, Left ventricular borders are traced from apical views. The algorithm compensates for skewed scan planes by stretching their borders lengthwise to match the longest long axis. The borders are then intersected with planes parallel to the mitral plane. B, Wire-frame representation of the reconstructed endocardial surface. (From Maehle J, Bjoernstad K, Aakhus S, et al: Echocardiography 1994;11:397–408.)
extensively validated in vitro and in vivo for left ventricular volume and mass[52] [53] [54] and can also be applied to the atria. Reconstruction can also be done based on a spherical coordinate system. In the method by Martin et al,[38] the x, y, and z coordinates of the manually traced borders are mapped into spherical coordinates before being fitted into a surface. These authors had developed a transesophageal echocardiography probe capable of recording images from both angulated and rotational sweeps.[55] Their approach was therefore designed to facilitate the handling of borders obtained from image planes with nontraditional orientations. An advantage of this method is that irregularly spaced and partial borders can be utilized. The method tends to round off all aspects of the ventricle, however, making it difficult to create sharp edges or orifices at the valves. A similar tendency to smooth out the valve planes is seen in a method based on deforming an initially spherical
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 23
211
TABLE 10-1 -- Accuracy in Measuring Ventricular Volume and Fun Reconstruction Chamber Standard Subject Method Studies in Phantoms and Heart Models Phantom True Balloons Connect borders Phantom True Balloons Polyhedral surface Phantom True Balloons Polyhedral surface
Patient, Parameter N r
Phantom True Phantom True Phantom True
Phantom True
Phantom True
Phantom True Phantom True
Balloons Spheric template Balloons Spheric template LV Volumetric models scan; sum of slices Balloons Piecewise smooth subdivision surface Balloon Volumetric + pump scan; sum of slices
Balloon Polyhedral + pump surface Balloons Bicubic spline
Volume
8 0.
Volume
17 0.
Volume
30 0.
Volume
11 0.
Volume
10 0.
Volume
23 0.
Volume
6 1.
EDV
29 0.
ESV
0.
EF
0.
Volume
—
Volume
8
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 23
Studies in in vitro Left Ventricles LV True Heart casts LV True Excised hearts LV True Excised hearts LV True Excised hearts LV
True
Heart casts Excised hearts Excised hearts Excised hearts Excised hearts
LV
True
LV
True
LV
True
LV
True
LV
True
Excised hearts
LV
True
Excised hearts
LV
True
Connect borders Connect borders Connect borders Connect borders; polar coordinates Polyhedral surface Spheric template Spheric template Spheric template Volumetric scan; sum of slices Piecewise smooth Subdivision surface Bicubic spline
Volume
5 0.
Volume
10 0.
Volume
11 0.
Volume
7 0.
Volume
15 0.
Volume
11 0.
Volume
28 0.
Volume
10 0.
Volume
14 0.
Volume
5 1.
Volume
Excised Volumetric Volume hearts scan; sum of slices LV True Excised Pyramidal scan; Volume hearts sum of slices Studies in Experimental Animals
11
7 0.
12 0.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 23
LV
Thermo
LV
Balloon in heart
LV
LV
LV
Balloon in heart
balloon in heart
Balloon in heart
Exptl Spherical animals coordinate system Exptl Spheric animals template
Exptl Spheric animals template
Exptl Spheric animals template
Exptl Spheric animals template
SV
57 0.
EDV
46 0.
ESV
38 0.
SV
38 0.
EF
38 0.
Volume
69 0.
SV
32 0.
EF
32 0.
EDV
19 0.
ESV
0.
SV
0.
EF
0.
Volume
84 0.
EDV
46 0.
ESV
38 0.
SV
38 0.
EF
38 0.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
LV LV
Pagina 8 di 23
Flow
Exptl animals Conductance Exptl catheter animals
Pyramidal scan; SV sum of slices Volumetric EDV scan; sum of slices ESV EF
LV LV
LV
LV
Balloon in heart Angio
Angio
Angio
Studies in Humans LV Doppler LV
Doppler
LV
MRI
Exptl Cylindrical animals Patients Sum of slices
Patients Connect borders; polar coordinates
Children Connect borders
Normal subjects Normal subjects Normal subjects
Spheric template Spheric template Polyhedral surface
Volume
14 0. 15 0.
0. 0. 11 0.
EDV
9 0.
ESV
7 0.
Volume
8 0.
SV
0.
EF
0.
Volume
26 0.
SV
0.
SV
19 0.
SV
14 0.
EDV
15 0.
ESV
0.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
LV
LV
Pagina 9 di 23
Angio
RNA
Normal Polyhedral subjects surface
Patients Polyhedral surface
EDV
39 0.
ESV
0.
EF
0.
EF
51 0.
0. LV
MRI
LV
Doppler
LV
MRI
Patients Polyhedral surface Patients Piecewise smooth subdivision surface Children Polyhedral surface
LV
Angio
Patients Polyhedral surface
LV
RNA
LV
MRI
Patients Volumetric scan; sum of slices Patients Volumetric and scan; sum of normal slices subjects
EDV
26 0.
ESV SV
0. 5 0.
EDV
12 0.
ESV EF EDV, ESV
0. 16 0.
EF
41 0.
EDV
46 0.
ESV
0.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
LV
Pagina 10 di 23
EF EDV
0. 24 0.
"
ESV
24 0.
"
EF
24 0.
SV
20 0.
EDV
50 0.
RNA,
ESV
0.
MRI
EF
0.
Angio
Patients Volumetric scan; sum of slices
Thermo LV
Angio,
Patients Bicubic spline
Right Ventricular Validation Studies RV True Heart Volumetric casts scan; sum of slices RV True Excised Volumetric hearts scan; sum of slices RV True Heart Replication and casts interpolation of three borders RV True Heart Piecewise casts smooth subdivision surface RV MRI Patients Volumetric scan; sum of slices
Volume
15 0.
Volume
14 0.
Volume
24 0.
Volume
10 0.
EDV
16 0.
ESV
0.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
RV
Pagina 11 di 23
MRI
Children Volumetric scan; sum of slices
EDV
13 0.
ESV
0.
EF
0.
2D, two-dimensional; Angio, ventricular angiography; EDV, end-diastoli volume; Exptl, experimental; LOA, limit of agreement (95%); LV, left vent subjects; R, Pearson correlation coefficient; RNA, radionuclide angiography standard error of the estimate; SV, stroke volume; Thermo, thermodilution.
214
Figure 10-12 Wire-frame reconstruction of a left ventricle using eight unequally spaced, nonintersecting short-axis image planes positioned with the line of intersection. (From Gopal AS, King DL: Threedimensional echocardiography. In Otto CM [ed]: Clinical Echocardiography. Philadelphia, WB Saunders, 1996, p 140.)
template along rays originating from the sphere's center to fit the traced data[36] (Fig. 10-13) . Nevertheless, this method has been flexible enough to reconstruct a variety of shapes, including excised ventricles and phantoms with localized protuberances, papillary muscle indentations, and aneurysms, and it accepts partial borders from images providing only limited visualization of the target chamber. It has yielded good accuracy in both left and right ventricular volume and mass measurement.[56] [57] [58] A method that measures ventricular volume accurately may not accurately represent the ventricle's three-dimensional shape, because there is an infinite number of shapes that contain a given volume. Most methods have been validated only for volume because no clinical applications Figure 10-13 Reconstruction using an initially spheric template. Left, Traced borders of human right ventricular cast with inflow region at upper left, apex below, and outflow at upper right. Right, Surface fitted to traced borders. (From Jiang L, Handschumacher MD, Hibberd MG, et al: J Am Soc Echocardiogr 1994;7:151–158.)
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 23
beyond volume, ejection fraction, and mass were foreseen. However, regional ventricular function, stress, and shape can only be analyzed using methods that reconstruct the ventricle with spatial accuracy. Only one method has been shown to faithfully reproduce the threedimensional shape of the ventricle: the piecewise smooth subdivision surface reconstruction method.[37] [37] This method was developed to avoid the inherent limitations of other methods, which restricted their anatomical accuracy or application to different three-dimensional image acquisition techniques. A triangulated abstract mesh is designed as a model for each ventricle. Because it embodies knowledge about the expected shape of the targeted structure, the abstract mesh allows diversely shaped structures to be reconstructed, such as the left and right ventricles, atria, and papillary muscles. For example, parts of the mesh can be marked as sharp to handle valve and venous orifices and the junction of the right ventricular septal and free walls (Fig. 10-14) . Additional facets can be added to produce complex shapes. In fitting the abstract mesh to the manually traced borders, the locations of anatomic landmarks such as the apex, borders of the interventricular septum, or papillary muscle insertions can be retained for future reference (Fig. 10-15) . All four chambers of the heart can be reconstructed (Fig. 10-16) . Two methods have been developed to evaluate a three-dimensional surface's spatial fidelity to an anatomic specimen. Pirolo et al[59] made a solid biventricular model from photographs of a canine heart cut into parallel short-axis slices and showed that measurements of slice volume, slice area, slice perimeter, and other dimensions were similar in the photographs and model. Since the images were made after the heart had been sliced, this approach avoided the difficult problem of aligning the model to the specimen to ensure that the measurements were made at anatomically corresponding locations. To validate the piecewise smooth subdivision method, surface reconstructions 215
Figure 10-14 (color plate.) The piecewise smooth subdivision surface reconstruction method begins with a control mesh that embodies knowledge concerning the expected shape of the target organ. A, For the right ventricle, the control mesh indicates that there are sharp edges (indicated by yellow line segments) around the orifices of the pulmonary and tricuspid valves (filled with pink) and between the septal (blue) and free (green) walls. B, Final surface
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 23
reconstruction of the same patient at end-diastole (wire mesh) and end-systole (blue). (From Sheehan FH, Bolson EL, McDonald AL: Comput Cardiol 2000;27:119–122. Copyright © 2000 IEEE.) Figure 10-15 (color plate.) In the piecewise smooth subdivision method, borders of anatomic landmarks can be carried through to the final surface reconstruction. A, Wire mesh display of borders traced of the left ventricular endocardium (black), mitral annulus (blue filled circles), aortic valve (green filled circles), and papillary muscles (red). B, On the fitted surface, the locations of the papillary muscle insertions are displayed in red.
216
Figure 10-16 All four chambers can be reconstructed using the piecewise smooth subdivision method. The atrioventricular valves are fitted using a Fourier series approximation,[98] and the aortic and pulmonary valve orifices are fitted to a planar ellipse.
of animal hearts generated by three-dimensional echocardiography were aligned using anatomic landmarks to laser scans of plaster casts of those hearts; the small orthogonal distance between the two three-dimensional data sets proved this method's spatial fidelity[37] [37] (Fig. 10-17) . Measurement of Volume The advantage of three-dimensional echocardiography is its avoidance of geometric assumptions concerning the shape of the ventricle that are required to estimate volume from one or two two-dimensional views. This is the reason for the superior accuracy of three-dimensional echocardiography in volume determination, since the suitability of geometric assumptions is less for diseased hearts than for normally shaped hearts. The advantage is greater Figure 10-17 The piecewise smooth subdivision method produces reconstructions that accurately represent the three-dimensional surface of the target organ.[37] Left, laser scan of a plaster cast of a left ventricular endocardium; right, surface reconstruction.
for the right ventricle. One reason is that its complex shape is more difficult to model geometrically than that of the left ventricle. In addition, the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 23
paucity of clear anatomic landmarks makes it difficult to obtain reproducible views; the resulting ambiguity in image plane position increases the variability of volume measurements by two-dimensional echocardiographic methods. It is actually not necessary to reconstruct the endocardial surface to measure ventricular volume. Simpson's method is a computationally simplistic approach that can avoid assumptions regarding the ventricle's shape if the heart has been imaged in closely spaced parallel image planes. Then the area enclosed by the endocardial border traced in each plane is multiplied by the distance between the planes to obtain the volume of its corresponding "slice" of the ventricle. The volume of the ventricular chamber is then computed as the sum of the slice volumes. As in integral calculus, the accuracy of the volume measurement and of the threedimensional shape representation increases with the number of slices or image planes. Once the ventricular endocardium has been reconstructed, volume is measured directly from that surface without further assumptions. For example, to determine volume from a triangulated mesh surface, the volumes of tetrahedra defined by each surface triangle and a common origin are summed. Validation of the accuracy of ventricular volume measurement by threedimensional echocardiography is performed both in vitro and in vivo. The robustness of a reconstruction method can be assessed from its ability to handle not only a range of ventricular sizes but also a variety of shapes, as might be observed in diseased hearts. In vitro testing permits validation against the true value rather than against the modality that threedimensional echocardiography is supposedly replacing. In vitro models include phantoms such as balloons or fixed heart specimens. Experimental in vivo validation has been performed by positioning a balloon within the left ventricle for measuring volume over the cardiac cycle.[60] Clinical validation is by comparison with other imaging modalities such as magnetic resonance imaging, radionuclide ventriculography, contrast ventriculography, or computed tomography, or with flow measurements by Doppler or thermodilution. All clinical imaging modalities have their respective sources of error and variability, however. For example, magnetic resonance images smooth out trabeculae on the ventricular endocardium, thus shortening the border and diminishing the computed volume.[61] Therefore, it can be argued that comparing the novel—in this case three-
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 15 di 23
dimensional echocardiography—with a more established imaging modality is actually an assessment of intermodality variability.[58] Because of the labor required to manually trace ventricular borders, it is advantageous to determine the minimum number of image planes that need to be analyzed and the effect of further data reduction on volume accuracy. Some investigators have found that volume or its derived parameters can be accurately determined from just three or four image planes.[15] [31] [32] [62] [63] [64] However, the standard error of the estimate when volume is measured from so few views is substantially larger than the 4 to 11 mL reported using borders from at least eight views.[30] , [51] [53] Buckey 217
et al[11] recommended at least six to eight planes, depending on the size of the ventricle. Their analysis was performed in vitro, however; a larger number of image planes may be needed clinically to compensate for poorer image quality. Tanabe et al[65] were able to obtain accurate volumes with only four to six axial images. Since this study was performed in small in vitro canine hearts, the results are comparable to a report that a 1 cm distance between serial parallel image planes suffices for the left ventricle. [66] In patients, left ventricular volumes measured from a three-dimensional image set acquired by rotational scanning and cut into 8-mm thick shortaxis paraplanes was comparable to volumes measured from 2.9-mm thick paraplanes, leading the authors to recommend the sparser data set for its speedier analysis.[67] However, because endocardial definition on paraplane images is poorer than on the original images used to synthesize them, the more complete volumetric data afforded by a dense rotational scan fails to provide superior accuracy over a simpler and faster freehand scan.[68] A theoretical analysis found that variability in left ventricular volume and mass determination by three-dimensional echocardiography decreases in proportion to the reciprocal square root of the number of slices.[69] In general, there is an inverse relationship between the knowledge inherent in the reconstruction method and the number of borders that must be traced. The spherical template method requires at least 8 to 12 images for accurate left ventricular volume determination but does not constrain the position or orientation of the images.[70] The polyhedral surface method utilizes fewer borders, eight or nine, but the reconstruction algorithm assumes nonintersecting short-axis image planes.[51] The piecewise smooth subdivision surface reconstruction method incorporates knowledge of the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 16 di 23
expected shape of the left ventricle via its abstract mesh.[37] It is thus able to provide accurate volume measurement and shape representation with as few as five randomly oriented left ventricular borders once the valve orifices have been defined.[71] Even this method cannot reconstruct the left ventricle from two borders, however. To proceed from such sparse data requires further shape assumptions such as relating the ventricle to an ellipsoid and produces only moderate accuracy (see Table 10-1) .[51] [53] Relatively little research has been performed to define the minimum amount of border data required to measure right ventricular volume accurately. Buckey et al[11] recommended at least six to eight planes for the right as well as the left ventricle, depending on the size of the ventricle. Janicki et al[66] recommend that more image data be acquired for the right ventricle because of its shorter longitudinal length and continually changing cross-sectional area. The smallest number of borders required uses just three standard, mutually orthogonal views (coronal, sagittal, and shortaxis), which are replicated and then interpolated.[72] Good accuracy is achieved by assuming that the shape of the coronal outline is constant over the anteroposterior extent of the ventricle. Measurement of Ventricular Mass The volume of a ventricle's myocardium is computed as the difference between its endocardial and epicardial volumes (Table 10-2) . Ventricular mass is determined by multiplying the myocardial volume by its specific gravity. Three-dimensional echocardiography has been shown in most studies to provide highly accurate and reproducible measurements of left ventricular mass; however, results for the right ventricle have been much poorer against both in vitro and in vivo standards. Reasons include incomplete visualization of the entire epicardium and greater obscurity of the myocardial-epicardial interface compared with the blood-tissue interface. The underestimation of right ventricular mass in one study was attributed to the surfacing method's tendency to round out sharp edges such as at the apex and distal outflow tract.[57] Measurement of Ventricular Function Nearly all validation studies have shown that measurement of ejection fraction by three-dimensional echocardiographic surface reconstructions more closely resembles the comparison standard than by two-dimensional techniques (see Table 10-1) . This is not unexpected, given the higher accuracy of three-dimensional echocardiography for volume measurement.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 17 di 23
Visual assessment of regional ventricular function can be performed from volumetric data sets using software to display each region dynamically. The image data can be cut to provide views that optimize endocardial definition and orientation. In one study, however, more segments could be visualized by standard two-dimensional echocardiography than from a real-time threedimensional echocardiographic scan. [73] Quantitative analysis of regional left ventricular function in three dimensions remains in its infancy, in part because most reconstruction algorithms fail to produce surfaces that are sufficiently faithful to the shape of the ventricular surface. Unlike volume, a measurement whose accuracy can be determined objectively, the analysis of regional function assumes knowledge of the pathway by which anatomic points on the left ventricular contour at end-diastole can be tracked to the same anatomic location at endsystole. For two-dimensional image analysis, attempts have been made to track endocardial "landmarks" or surgically implanted midwall markers. The wide discrepancy (90 degrees) between the trajectories for apical motion derived from these tracking studies acts to diminish confidence in their validity, however. The alternative is to use models of wall motion instead (for a wider discussion, see Chapter 5 ). The models developed to analyze wall motion from three-dimensional image sets are similar to those for two-dimensional images. An example is measuring wall motion radially toward a central origin or long axis.[7] [74] Because of the lack of objective evidence, such models are validated using empirical criteria such as sensitivity and specificity in distinguishing normal subjects from patients, just as was done for two-dimensional models. One study compared six reference systems and found greatest agreement with visual assessment when wall motion is measured toward the long axis.[75] More studies have been performed assessing regional function from the local change in wall thickness. Wall thickening more accurately reflects function 218
TABLE 10-2 -- Accuracy in Measuring Ventricular Mass by Three-Di Reconstruction Patients, Chamber Standard Subject Method N r SEE Re LV True Excised Polyhedral 11 0.995 2.91 Y =
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 18 di 23
LV
True
LV
True
LV
True
LV
True
LV
True
LV
True
hearts surface Excised Piecewise hearts smooth subdivision surface Excised Volumetric hearts scan; sum of slices Excised Bicubic spline hearts Excised Volumetric hearts scan; sum of slices Excised Pyramidal scan; hearts sum of slices
Excised after scan LV True Excised after scan LV at risk Contrast Exptl animals LV
MRI
LV
MRI
LV
MRI
Volumetric scan; sum of slices Pyramidal scan; sum of slices
Volumetric scan; sum of slices Normal Polyhedral subjects surface Children Polyhedral surface Patients Volumetric scan; sum of slices
8.2 5 0.998 2.5 Y = +1
7 0.95 11.97 Y = - 2. 15 —
14 0.98
12 0.99
—
M diff 1.4 9.6 Y = +0 2.8 Y = +0
8 0.997 1.05 Y = 2.2 21 0.94
8.5 Y = +1
8 0.947 21
Y= +2
15 0.93
9.24 Y = +1 12 — — M diff 5.8 12 0.78 35.8 Y = 0.6
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 19 di 23
LV
MRI
LV
MRI
RV
True
Patients Volumetric scan; sum of slices Patients Deformable shell
20 0.99
8.5 Y = 0.7
25 0.99
6.9 Y = +1
Excised Piecewise 10 0.996 4.5 Y = hearts smooth subdivision surface RV True Hearts Polyhedral 12 0.96 2.7 Y = +0 excised surface after scan RV MRI Patients Volumetric 16 0.65 — Y = scan; sum of +1 slices 1D, one-dimensional; 2D, two-dimensional; ED, end-diastolic; ES, end-sy left ventricle; MRI, magnetic resonance imaging; RMS, root mean square; S estimate. in hypertrophied hearts[76] and is independent of artifact caused by cardiac translation. The disadvantage is the need to trace and reconstruct the epicardium in addition to the endocardium. This doubling of work is not merely time consuming but also introduces additional opportunity for error. Imaging must be performed with the intent to quantify regional wall thickening, so care is needed to ensure that the epicardium is included in the scan sector throughout the cardiac cycle. Three-dimensional wall thickening analysis requires measurement of wall thickness orthogonal to the left ventricular wall. Analysis can been performed using twodimensional techniques on short-axis image planes located near the middle of the left ventricle. Accuracy is necessarily diminished in the more apical planes, however, where the oblique sectioning causes wall thickness to be overestimated. One method to measure regional wall thickness orthogonal to the left ventricular wall is to segment the myocardium into 64 elements and divide
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 20 di 23
each element's volume by the mean distance between its endocardial and epicardial surfaces. [77] The centersurface method measures wall thickness along locally orthogonal vectors in the same way as in the centerline method for two-dimensional borders.[41] [78] [78] The vectors are normal to a three-dimensional medial surface constructed midway between the endocardial and epicardial surface reconstructions (Fig. 10-18) . Wall thickening is computed as the change in thickness normalized by the local end-diastolic wall thickness. To indicate the severity of an observed value's deviation from normal, thickening can be converted to units of standard deviations from the mean of the reference population, analogous to the approach used in two-dimensional measurement [78] [78] (Fig. 10-19) . Regional left ventricular function has also been evaluated from reconstructions of the endocardium and epicardium using finite element analysis. [79] More recently, a biomechanical model has been developed incorporating information about local fiber direction as well as material properties. The deformation of the myocardium was tracked between enddiastole and end-systole using curvature analysis.[80] The strain measurements predicted by this model have agreed well with sonomicrometer measurements in vivo.[81] Estimation of Infarct Size Infarct size is assessed from echocardiograms by measuring the amount of dysfunctional myocardium. The underlying assumption is that the extent of infarction correlates linearly with the extent of dyssynergy.[82] As in measuring ventricular volume, accuracy depends on the number of echocardiographic image planes analyzed and on the assumptions concerning the spatial location of the image planes and the geometry of left ventricular shape. Owing to limited visualization of the left ventricle, twodimensional echocardiographic approaches have quantified the proportion of infarcted myocardium, such as its 219
Figure 10-18 (color plate.) The centersurface method permits measurement of wall thickness orthogonal to the local myocardial wall. [158] Here the close and distant thirds of the left ventricle have been "cut away" to provide a tomographic view. A medial surface (green) is constructed midway between the endocardium (yellow) and the epicardium (blue). Chords are drawn perpendicular to the centersurface and extended
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 21 di 23
to the endocardial and epicardial surfaces. The length of each chord is the local wall thickness.
circumferential extent in a short-axis view, rather than absolute infarct mass.[83] [84] [85] Such proportional measurements are unsuitable for serial studies because the fraction is affected by myocardial remodeling and thinning of the infarct region. Because of the more comprehensive assessment of the left ventricular surface, three-dimensional echocardiography yields absolute infarct size measurements that correlate closely with the true values in experimental animals.[86] [87] The principal difficulty with estimating infarct size from the extent of dyssynergy is deciding whether to include hypokinetic myocardium in the infarct region. Theoretically, including hypokinetic myocardium will overestimate infarct size because akinesis results from fibrosis of as little as 25% of the thickness of the myocardium.[88] If the infarct is transmural, then the infarct mass is truly equivalent to the mass of myocardium displaying akinesis or dyskinesis.[87] However, the transmurality of an infarction is difficult to determine ante mortem. When regional function is quantified rather than assessed visually, it is still necessary to select a threshold. In one clinical study, infarct mass by magnetic resonance imaging was associated with myocardium having absolute wall thickening greater than 2 mm.[89] The area of dysfunctional endocardium has been reported to correlate better with histopathologic infarct size than does the mass of dysfunctional myocardium, probably because of assumptions in the mass calculation.[86] Perhaps more importantly, three-dimensional measurements are also more consistent and less variable than two-dimensional.[86] The advantage here is that use of this metric as a clinical trial end point may reduce the number of patients needing to be enrolled. Following coronary occlusion, echocardiographic contrast material can be injected to define the size of the region at risk of infarction by its failure to show contrast enhancement.[90] [91] The contrast defect region corresponds to the infarct region in the absence of coronary reperfusion. Using volumerendering techniques, the size and location of the perfusion defect can be displayed within the framework of the reconstructed ventricle. Shape There has been relatively little progress in developing techniques for analyzing regional left ventricular shape from three-dimensional echocardiographic data. Most of the research has been conducted on
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 22 di 23
magnetic resonance images despite the poor spatial resolution in the longitudinal axis. However, the methods developed for one modality are theoretically transferable to another modality. The most common approaches to shape analysis are geometry based. Regional curvature analysis has been applied for tracking endocardial displacement [80] and analyzing regional left ventricular strain. [81] The center-axis method measures distance radially from the long axis to the endocardial surface[92] (Fig. 10-20) . Its advantage is ease of computation; however, the results shift with the location of the long axis. The alignment method differs conceptually from previously described shape analysis methods because it directly compares the shape of a patient's heart with a reference heart after aligning them along regions of similar topography[93] (Fig. 10-21) . Shape differences are then Figure 10-19 (color plate.) Example of the visual presentation of regional left ventricular function in three dimensions. Here the wall thickening at each vertex has been converted into units of standard deviations from the mean of a normal reference population. Cool colors represent levels of hypokinesis; warm colors, hyperkinesis (color scale developed by S. Maza). Visualization as an overlay on the patient's three-dimensional surface facilitates appreciation of the location, extent, and severity of dysfunction.
220
Figure 10-20 A, The center axis method measures regional shape in terms of radial distance from a center axis to the endocardial surface. To normalize for heart size, the distance from the center axis to the reconstructed surface is divided by center axis length. The left ventricle is divided into 16 segments whose shape is calculated as the mean radial distance of the points lying within that segment to the center axis. B (color plate.), The severity of shape abnormality is displayed using a color scale allowing visual appreciation of the difference between a normal subject (NL74) and anterior and anterolateral dilation in a patient with idiopathic dilated cardiomyopathy (CM99). (From Munt BI, Leotta DF, Martin RW, et al: J Am Soc Echocardiogr 1998;11:761– 769.) Figure 10-21 (color plate.) The alignment method measures regional shape in terms of distance between the patient's heart and a reference such
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 23 di 23
as normal average heart.[93] Here a normal end-diastolic left ventricular endocardial surface (mesh) has been deformed at the inferoapical wall (arrow) and aligned with its original, undeformed self (red surface) along regions of similar shape. The magnitude of shape abnormality can be quantified using the centersurface algorithm.
221
measured in terms of local orthogonal distance between them. Applications of regional shape analysis include assessing left ventricular remodeling following acute myocardial infarction,[93] [94] assessing regional stress,[95] and defining the pathophysiology of functional mitral regurgitation.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/84.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 5
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Quantitative Analysis of the Valves Three-dimensional echocardiography has contributed much more to the understanding of valvular heart disease than to the understanding of the ventricles. The ability to reconstruct the three-dimensional geometry of the valves, associated structures, and blood flow has not only provided mechanistic insight into the nature of disease processes but also totally altered our perception of normal cardiac anatomy. Owing to the dynamic nature of valvular function, which cannot be appreciated in the arrested heart, surgeons must rely on preoperative assessment based on imaging. For this reason, it has been a major focus of investigation to improve our knowledge of the structure-function relationship to better assist in surgical planning. Mitral Valve and Mitral Apparatus It was three-dimensional echocardiography that finally provided the tools for elucidating the saddle shape of the mitral annulus in humans.[96] Through three-dimensional reconstructions, this study demonstrated how the alignment of leaflet to annulus in the apical four-chamber view can give the artifactual appearance of mitral valve prolapse, resulting in false diagnosis by two-dimensional echocardiography. The underlying concept, that incomplete Figure 10-22 Schematic of the mitral annulus as reconstructed in three dimensions using Fourier series. The various dimensional parameters provide assessment of annular shape. (From Kaplan SR, Bashein B, Sheehan FH, et al: Am Heart J 2000;139:378–387.)
visualization of complex anatomical structures can lead to profound misunderstanding of their functionality, has stimulated the application of three-dimensional echocardiographic evaluation of numerous other cardiac
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 5
pathologies to ensure that similar oversights are avoided. The most studied component of the mitral valve apparatus is the annulus. It can be visualized clearly from a rotational transesophageal scan and reconstructed by fitting a smooth spline curve or Fourier series approximation to the traced points.[97] [98] The area and eccentricity of the annular orifice are measured from its projection onto a least squares fitted plane. Annular height is measured relative to this plane. The accuracy of three-dimensional echocardiography for measuring these parameters has been validated in vitro.[98] Additional parameters of interest are its peak-topeak and valley-to-valley spans and annular motion, consisting of descent toward the left ventricular apex and tilting (Fig. 10-22) . Four-dimensional analysis of the annulus' shape change throughout the cardiac cycle is performed by reconstructing the annulus at multiple time points defined either from cardiac events or by normalization.[99] [100] [101] [102] The shape and dynamics of implanted annuloplasty rings can also be analyzed.[103] Ignoring the valve's three-dimensional shape, annular area can be estimated by planimetering its apparent orifice from short-axis paraplanes.[104] All components of the mitral apparatus can be reconstructed and analyzed quantitatively, not just the annulus. Leaflet reconstruction permitted analysis of leaflet-annular relations.[96] The left ventricle and left atrium can be reconstructed using surfacing methods.[105] The papillary muscles can be located and measured even though they are difficult to reconstruct because of their highly variable anatomy, and the chordae tendineae can be analyzed for position and orientation[105] (Fig. 10-23) . Such measurements are useful for evaluating functional mitral regurgitation.[42]
222
Figure 10-23 (color plate.) Reconstructions of the left ventricular endocardium at end-diastole and the papillary muscles of a normal subject (left) and a patient with idiopathic dilated cardiomyopathy (right). The principal chordae tendineae proceeding from each papillary muscle head are displayed as pink or green line segments. The reconstructions enable visualization of the enlargement of the left ventricle, the outward displacement of the papillary muscle insertions, and the divergence of the chordae tendineae in the cardiomyopathy patient.
Aortic Valve
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 5
There are several theoretical advantages of three-dimensional echocardiography for measurement of aortic valve area. First, direct planimetry of the valve's cross-sectional area or measurement of its radius from two-dimensional echocardiography is subject to error because of offaxis imaging of the valve, especially if shape is distorted due to congenitally bicuspid or degenerative stenosis. Second, calculation of valve area using the continuity equation method depends on proper positioning of the Doppler sample volume. Malpositioning of the image plane by as little as 10 degrees or 1.5 mm causes significant overestimation of valve area.[106] Three-dimensional echocardiography permits the orifice to be directly planimetered from a paraplane image that is correctly positioned anatomically in the true orifice, providing more consistent agreement with area determined by the Gorlin formula or the Doppler continuity equation than planimetry from two-dimensional images.[107] Regurgitant Flow The application of three-dimensional echocardiography for measurement of regurgitant flow rate using three-dimensional echocardiography promises an improved means for estimating effective orifice area and regurgitant volume, which are more reliable indicators of regurgitation severity. The increased accuracy that has been achieved can be attributed to avoidance of geometric assumptions inherent in the two-dimensional proximal isovelocity surface area (PISA) method. These assumptions are that the isovelocity surface is hemispheric in shape, the orifice is small and circular and lies on a flat surface, and the region adjacent to the flow convergence region is free of flow interference. To date, more research has been performed for assessment of mitral than aortic regurgitation. One reason is that the saddle shape of the mitral annulus and the variable leaflet topography violate the assumptions of the PISA method. There are several approaches for assessing valvular regurgitation that totally avoid using the PISA method. These methods are subject to pathophysiologic variations and imaging factors, however. One threedimensional approach is measurement of the regurgitant orifice area from a volumetric data set by direct planimetry from a cut plane providing a left atrial view of the orifice at its maximal area.[108] The authors validated it in vivo by demonstrating agreement between the three-dimensional and PISA measurements. Another approach is to analyze the dimensions of the regurgitant jet from multiplanar color Doppler images. For example, threedimensional Doppler measurement of proximal cross-sectional jet area
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 5
correlated well with vena contracta area determined using laser flow visualization in vitro, although with 25% overestimation despite optimization of gray level threshold and color gain.[109] This error was attributed to poor lateral resolution of Doppler echocardiography, resulting in difficulty delineating the edge of the jet core from the adjacent entrainment flow. Jet volume agreed closely with mean and peak regurgitant flow, regurgitant fraction, and regurgitation stroke volume by electromagnetic flow meter in animal models of aortic regurgitation.[110] [111] Jet volume also agreed closely with angiographic grade of regurgitation in patients with eccentric as well as central jets, whereas two-dimensional jet area predicted regurgitation severity in central jets only.[112] One reason for the 223
greater accuracy of three-dimensional analysis is difficulty finding the plane displaying the maximum area of wall jets and eccentric jets from two-dimensional images. It is important to be aware that the relationship between jet volume and regurgitant flow-rate varies with Doppler angle, jet origin, jet-wall relationship (centric or eccentric), and orifice shape.[113] [114] It is possible to modify the PISA method to eliminate invalid assumptions. In vitro studies have shown that a number of factors affect the size and shape of the isovelocity surface. Its area varies with orifice shape, being larger for elongated split orifices than for circular or triangular orifices. Its shape is flattened near the orifice and eccentric for eccentric orifice shapes. One three-dimensional study described the shape of the flow convergence region as "complex and unpredictable" in its variety.[115] The varying local shape of the isovelocity surface away from hemispheric reflects the variations in leaflet and inlet geometry.[116] Simply reconstructing the actual three-dimensional isovelocity surface observed from Doppler data has been shown to enhance accuracy in measuring aortic regurgitation in an animal model.[117] The analysis of the regional shape of the three-dimensional reconstruction can be taken one step further, to compute the flow rate at each constituent of the Doppler isovelocity surface from its area and anglecorrected velocity (Fig. 10-24) . Integration over the entire surface generates a regurgitant flow measurement that correlates with true flow in vitro over a range of flow-rates and orifice shapes.[114] This is thus a Figure 10-24 (color plate.) Cut-away view of Doppler isovelocity
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 5
surfaces in the flow convergence region (FCR), as measured at three velocity thresholds. The surfaces are flattened and elongated, reflecting the eccentric shape of the orifice (rectangular).[159]
geometry-independent method for quantifying regurgitant flow.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/85.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Processing Three-Dimensional Echocardiographic Data for Visual Assessment Visual assessment of image data has two forms. Volume rendering is a three-dimensional presentation of image data from closely positioned planes to obtain a realistic "surgeon's eye" view of the heart primarily for visual assessment. [118] For displaying the results of a quantitative analysis, three-dimensional surface reconstruction and graphics may be employed to facilitate appreciation of the anatomic location and extent of observed abnormalities. In volumetric mode, multiple images are acquired in close proximity and regular intervals and processed to create voxels, or three-dimensional image elements. Digital reformatting and image processing may be used to fill the space between image planes through interpolation to obtain a solid volume of voxel data, align the image data temporally, segment the tissue from the blood pool, and filter out noise and artifact. An algorithm assigns a binary value to each voxel to classify them as lying within versus outside the myocardium. The surface of the myocardium is generated by the computer from the boundary between voxel classes. The spatial dimension is displayed using volume rendering, a format that uses different gray levels 224
to indicate the depth of cardiac structures so that those lying "further" from the viewer are dimmer. Image processing tools are applied to give the sense of reality to the presentation, for example hiding distant regions that lie behind proximal regions. Lighting can also be arranged to illuminate "closer" features more brightly and cast shadows on surfaces behind them. The feeling of depth can be enhanced by computing pairs of images that are slightly rotated relative to each other and presenting one of these to each eye to create a stereoscopic display. Another tool allows the voxel set to be rotated and translated smoothly so that the viewer can peer into the heart
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
from different perspectives. One advantage of volumetric imaging is the ability to compute twodimensional cross sections ("any-plane views") in planes that could not be acquired from standard precordial or transesophageal transducer positions. [3] [6] The quality of such synthetic images tends to be inferior, however, probably because of the interpolation required to fill in gaps between the original images. Most frequently, volumetric images are acquired using a mechanical device to obtain a closely spaced rotational scan. Techniques are being developed for interpolation between images acquired at high spatial frequencies from angulated freehand scans, however.[119] Recently, a method has been developed for spatial compounding of ultrasonographic images that combines information from multiple views while assigning higher weights to image data acquired at a near 0 incidence angle to the ultrasound beam. [120] Applied to scans of the shoulder, the method improved image quality in synthetic planes as demonstrated by reduction in the width of the border of the bone and lessened variability in intensity along the border. This kind of novel technology thus can enhance the information content of paraplane images while permitting combined volumetric analysis of multiple freehand scans. Prior to the ready availability of three-dimensional computer graphics and inexpensive computers, multiplanar image data were presented in various two-dimensional formats. One approach is to divide the left ventricle into four longitudinal quadrants that can be laid out "flat."[121] This permits assessment of endocardial surface area and area of infarcted myocardium based on regional dysfunction.[85] The left ventricle can also be presented as a bull's eye; however, regional areas are distorted, with particular exaggeration of the area of the base.[35] [47] This distortion can be avoided by mapping the multiplanar two-dimensional data onto a three-dimensional surface reconstruction of the ventricle (see Fig. 10-19) .
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/86.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 9
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Applications of Three-Dimensional Echocardiography Clinical Applications The avoidance of geometric assumptions in measuring ventricular volume is an important factor in the greater accuracy of three-dimensional as compared with two-dimensional echocardiographic techniques. This is even more evident when evaluating disease-distorted hearts. For example, the volume, mass, and ejection fraction of left ventricles compressed by pulmonary hypertension and in single ventricles of left ventricular morphology is more accurately determined by three-dimensional than by two-dimensional echocardiography (using magnetic resonance imaging as the standard).[122] [123] Similarly, the asymmetric crescent shape of the right ventricle poses problems for modeling from two-dimensional views but can be accurately represented using three-dimensional echocardiography, even in patients with congenitally distorted anatomy.[14] The anticipation is that three-dimensional echocardiographic techniques are useful for monitoring patients at risk of developing right ventricular dilation and heart failure. Similar methods can also be applied for measuring atrial volume.[124] Pericardial effusion volume is more accurately measured by threedimensional than by two-dimensional echocardiography. The reasons extend beyond the elimination of geometric assumptions concerning the shape of the ventricle and the spatial location and orientation of the image planes. In particular, three-dimensional echocardiography affords better visualization of all levels of the heart and is thus able to handle loculated effusions that may be asymmetrical in shape and unusual in location.[125] Another clinical application in which three-dimensional echocardiography has proven superior to two-dimensional is measurement of aneurysm volume.[126] [127] The avoidance of geometric assumptions and ability to accept and utilize nonstandard views combine to permit reconstruction of the aneurysm separate from the body of the left ventricle. This tool may be
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 9
useful in planning surgical repair, estimating the size of the residual left ventricle, evaluating the stroke volume wasted by dyskinesis, and computing the expected functional benefit of surgery. Diagnosis The volumetric mode offers great potential for enhancing the diagnostic yield of an echocardiographic examination for several reasons. First, the possibility of cutting the image data in any plane reduces reliance on sonographer experience and skill and may even provide views that are difficult to acquire from traditional acoustic windows.[3] [6] That is, the size, shape, and motion of cardiac abnormalities can be displayed from any perspective. Even static views, when displayed from different perspectives, can assist in identifying structural abnormalities, visualizing their shape, and measuring their extent. The volume-rendered display assists experienced reviewers in diagnosing congenital, valvular, and structural pathologies, presumably by reducing the requirement for mental integration of the image data, so that sensitivity and specificity for discriminating normal from abnormal hearts is significantly enhanced compared with diagnosis from two-dimensional views.[128] Three-dimensional imaging has been estimated to provide improved spatial understanding of cardiac pathology over conventional transesophageal echocardiography in about one third of cases.[129] Transthoracic three-dimensional echocardiographic image sets provide information not seen in the two-dimensional study in the same proportion (one third) of adults with congenital heart disease. [130]
225
One application is to assess the extension of abscesses into neighboring structures and to visualize mass lesions.[131] Another application is assessment of cardiac tumors to determine their shape, dimensions, origin, location, and involvement of valves prior to surgery.[132] Cutplane views provide a surgeon's eye preview of cardiac anatomy, for example, of the aortic valve from an aortotomy or of the mitral valve from above or below ("atriotomy" or "ventriculotomy" view).[133] It is speculated that such visualization may prove useful in surgical planning. For example, mitral valve abnormalities could be visualized as they would be seen intraoperatively for discussion with surgical consultants.[17] In patients with congenital anomalies, three-dimensional echocardiography provides additional diagnostic information on the mitral valve, aortoseptal
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 9
continuity, atrial septum, and atrioventricular septal defects.[130] [134] Identifying small lesions or visualizing thin structures such as the aortic valve is beyond the resolution of the image, however.[130] To facilitate interpretation, cutting planes can be displayed dynamically to review the motion of valves or other segments of cardiac anatomy. Intrauterine sonography can provides prenatal assessment of anatomic and functional status regarding the myocardium, valves, and great vessels.[135] Therapy Planning and Assessment Volumetric imaging has been touted for therapeutic evaluation of atrial septal and other congenital defects because it can cut the image data to provide en face views that provide direct visualization of the defect in children and adults by the transesophageal or transthoracic approach.[133] , [136] These views provide information on the shape of the defect and its location relative to adjacent structures. However, measurement of its size and shape from en face views has variable accuracy.[134] [137] [138] [139] Clinical applications are presurgical planning and evaluation of the success of transcatheter closure of the defect.[138] Transesophageal three-dimensional echocardiography of ventricular septal defects can also be performed to quantify their location relative to ventricular apices and valve insertions, area, and circumference, for planning surgical or catheter repair.[140] Intraoperative transesophageal three-dimensional echocardiography of the valves provides the surgeon with information complementary to that yielded by routine two-dimensional echocardiography in the form of additional morphologic definition or interpretation of abnormalities seen on two-dimensional study.[141] In this study, the greatest contribution as well as the greatest error of three-dimensional echocardiography was in identifying leaflet fenestrations. Visualization of the valve leaflets during mitral balloon valvuloplasty can be performed from the esophageal window to monitor the process, guide and optimize commissural splitting, and minimize valvular regurgitation by arresting the procedure once minor leaflet tears appear. [142] The functionality of rigid mitral annuloplasty rings and their impact on outflow tract patency can be assessed using threedimensional imaging and reconstruction.[143] These studies were performed using magnetic resonance imaging, but three-dimensional echocardiography analytic tools are currently available and can be applied to assess the flexibility of mitral annuloplasty rings even when the absolute accuracy of annulus dimension is suboptimal.[96] [98] [144] Volumetric reconstruction has also been shown to assist in presurgical
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 9
planning for right as well as left ventricular outflow obstruction by providing visualization of the morphology of the obstruction.[145] [146] Reconstruction of the left ventricular outflow tract by tracing its border from parallel short-axis paraplane images provides characterization of the anomalies specific to hypertrophic cardiomyopathy, identification of abnormal geometry that may prove useful in understanding the mechanism of obstruction, and assessment of the efficacy of surgery in remodeling the outflow tract.[147] Physiology and Pathophysiology Three-dimensional echocardiography has unparalleled potential for elucidating the mechanism of disease processes, owing to its high spatial and temporal resolution. For example, four-dimensional analysis of the annulus has permitted characterization of how the normal mitral valve achieves area reduction during systole through a combination of perimeter shortening and shape modulation.[101] [102] Such techniques permit measurement of the extent to which annular dynamics and static dimensions may be altered by disease processes such as ischemic heart disease or cardiomyopathy. Three-dimensional echocardiographic analysis of the components of the mitral apparatus has been instrumental in elucidating the cause of functional mitral regurgitation.[101] [148] [149] Serial Studies Measurements of ventricular volume, mass, and ejection fraction by threedimensional echocardiography are far more reproducible than by twodimensional echocardiography or by visual assessment (Table 10-3) . The clinical advantage of reproducible measures is sensitivity in detecting changes in a patient's condition. For example, patients with valvular lesions require close monitoring to select optimal timing for a surgical repair. Another important clinical application is the long-term monitoring of right ventricular volume and function following surgical repair of congenital defects such as Fallot's tetralogy in patients with residual pulmonary valve dysfunction or an intra-atrial baffle for transposition of the great arteries. With two-dimensional techniques, variability was introduced by estimating right ventricular volume from image planes whose anatomic position may have been difficult to reproduce from study to study. With threedimensional imaging, this source of error is eliminated. One analysis of interobserver variability reported that three-dimensional echocardiography has a 92% to 95% probability of detecting a change of 15
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 9
mL in left ventricular end-diastolic volume, of 11 mL in end-systolic volume, 226
TABLE 10-3 -- Variability in Measuring Ventricular Volume and Fu Patients, Method Parameter N Interob Polyhedral Volume 17 4. Polyhedral Volume 30 2.65
Chamber Standard Subject Phantom True Balloon Phantom True Balloon; distortions Phantom True Balloon Spheric Volume template Phantom True Balloon Volumetric Volume with scan; sum pump of slices EF LV True Excised Spheric Volume hearts template LV True Excised Spheric Volume hearts template LV True Excised Bicubic Volume hearts spline LV True Excised Volumetric Volume hearts scan; sum of slices LV True Excised Pyramidal Volume hearts scan; sum of slices LV True In vivo Spheric Volume (balloon) template LV True In vivo Volumetric Volume (balloon) scan; sum of slices LV Balloon Exptl Cylindrical Volume
11
2
29
1
11
3 4
28
3
11
-1
7
13
12
0.8 ±
14
3
14
2.
11
6±
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 9
in heart
animals
LV
Doppler
LV
MRI
Normal subjects Normal subjects
LV
Angio
Patients
LV
RNA
Patients
LV
MRI
Patients
LV
RNA
Patients
LV
MRI
Patients
LV
Angio
Patients
LV
MRI
Patients and normal subjects
Spheric SV template Polyhedral EDV
14
2
15
4.
ESV Polyhedral EDV
39
10
51
8 — 10
26
8
25
7 4 5
12
<
16
< < 1.9 ±
ESV EF Polyhedral EF surface Polyhedral EDV surface ESV EF Volumetric EF scan; sum of slices Polyhedral EDV surface ESV EF Polyhedral EDV surface ESV Volumetric EDV scan; sum of slices
46
6
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
LV
LV
Pagina 7 di 9
Angio
Angio, RNA, MRI
Patients
Patients
ESV EF Volumetric Volume scan; sum of slices EF Bicubic EDV spline
24
3 3 3
10
3 6
ESV 3 EF 3 RV True Heart Volumetric Volume 15 4 casts scan; sum of slices RV MRI Patients Volumetric EDV 16 4 scan; sum of slices ESV RV MRI Children Volumetric EDV 13 1.4 ± scan; sum of slices Angio, ventricular angiography; EDV, end-diastolic volume; EF, ejection experimental; LV, left ventricle; MRI, magnetic resonance imaging; RNA, r standard deviation; SEE, standard error of the estimate; SEM, standard error and a change in ejection fraction of 2% when a rotational scan is performed at 16-degree increments.[150] Another observer variability study found that three-dimensional echocardiography can detect a smaller change in left ventricular volume (11 to 13 mL) with 95% confidence than twodimensional echocardiography, which can only detect change that exceeds 21 to 24 mL.[69] However, no difference in variability was found between two-dimensional and three-dimensional measurement of mass.[69] An advantage also accrues to clinical research, since fewer patients need be enrolled in a clinical trial to obtain statistical power to detect a treatment effect.[151] Aid to Clinical Image Acquisition
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 9
227
Unlike other tomographic imaging modalities, standard ultrasonographic image acquisition is heavily dependent on the skill and experience of the sonographer. It is often difficult to obtain standard views of the right ventricle.[14] Studies have shown that even standard views of the left ventricle are difficult to acquire consistently in the prescribed location, even by experienced sonographers. [33] Consequently, referral centers frequently repeat studies rather than trusting a study from an outside hospital or clinic. The resulting worsening of medical costs and inefficiency can, however, by improved by three-dimensional technology. One approach is to assist the sonographer in locating anatomically correct image planes for the standard two-dimensional echocardiographic views. An image plane positioning error that foreshortens the long axis by 1 cm may underestimate left ventricular volume by 5%.[7] By tracking the transducer, a line of intersection can be displayed on the ultrasonographic image that indicates the current image plane's position in relation to a previously acquired scout image to provide visual guidance (Fig. 10-25) . Such a system has been shown to reduce interobserver variability to one third the level observed for unguided measurements.[152] Performing three-dimensional echocardiography, which does not require standard views, yielded more accurate and reproducible ejection fraction determinations by novice sonographers that approached the performance of experts using twodimensional echocardiography in accuracy and reproducibility of ejection fraction determination.[153] Experts were always more accurate than novices for either three-dimensional or two-dimensional measurement, but the three-dimensional technology allowed novices to acquire Figure 10-25 Visual guidance to facilitate ultrasonogram acquisition in the anatomically correct spatial planes. A and B, A line of intersection indicates the spatial location of the current image plane where it intersects with "scout" images previously acquired in orthogonal views. C and D, More guidance is provided when the spatial orientation as well as location of the current image plane (translucent image) are displayed relative to the scout images.
228
data sets of diagnostic quality. It is speculated that three-dimensional
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 9
echocardiography may permit echocardiography in regions lacking skilled sonographers, if combined with remote expert interpretation. Modeling Three-dimensional echocardiography offers the ability to reconstruct the chambers, valves, and other structures of the heart in the highest spatial and temporal resolution of any imaging modality. These data have many potential uses. For example, surgeons involved in designing a total artificial heart have sought improved annular definition for planning inflow and outflow ports of the device. [154] Reconstructions of the endocardium and epicardium are useful for finite element analysis of left ventricular stress and material properties. [155] Heart reconstructions can also be used to model the stress and fatigue of pacemaker leads in any combination of implantation configurations[105] [156] (Fig. 10-26) . Three-dimensional echocardiographic reconstructions of valve geometries seen in mitral stenosis have been used to generate models by stereolithography for analysis of the relationship between cardiac structure, pressure, and blood flow.[157]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/87.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Summary Three-dimensional echocardiography has the potential to become a major clinical imaging modality because it Figure 10-26 Reconstruction of a normal right ventricle illustrating its use for measuring various internal dimensions, such as the distances spanning the apex and centroids of the tricuspid and pulmonary valves (white lines). (From Sheehan FH, McDonald AL, Bolson EL: Paper presented at 11th International Conference on Mechanics in Medical Biology, April 2–5, 2000, Maui, Hawaii.)
offers realistic visualization and accurate quantitation in combination with ultrasonography's traditional advantages of cost, portability, and freedom from ionizing radiation. These qualities already make three-dimensional echocardiography a valuable and productive tool for clinical research. Application of three-dimensional echocardiography to the clinical environment awaits the development of automated image analysis.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/88.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 3
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Section 3 - Ischemic Heart Disease
235
Chapter 11 - The Role of Echocardiographic Evaluation in Patients Presenting with Acute Chest Pain to the Emergency Room Diagnosis, Triage, Treatment Decisions, Outcome Samuel Wang MD Kirsten E. Fleischmann MD, MPH
Background and Principles Several million patients in the United States each year present to emergency rooms with chest pain suggestive of acute coronary syndrome. However, a minority of these patients are ultimately diagnosed with myocardial ischemia or infarction.[1] [2] Conversely, approximately 5% of those with acute myocardial infarction are mistakenly discharged from the emergency room.[3] [4] A considerable body of evidence has accumulated since the 1980s supporting the hypothesis that early treatment of myocardial infarction improves the rate of coronary arterial patency, myocardial salvage, and patient survival.[5] [6] [7] [8] [9] Thus, it is clear that
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 3
early diagnosis and treatment of acute chest pain have significant benefits for the individual patient, and for the society that finances the health care. The diagnosis of myocardial infarction is usually made on the basis of the patient's clinical history, electrocardiogram (ECG), and serum cardiac enzyme levels. Although these three methods in combination provide a relatively effective diagnostic approach, each has its own limitations. Patients presenting with "atypical chest pain" not infrequently rule in for myocardial infarction; on the other hand, patients presenting with symptoms typically associated with acute coronary syndrome may not, in fact, have myocardial ischemia or infarction. Although ST-segment changes on ECG provide a useful diagnostic tool for acute coronary syndrome, they may be absent in the initial ECG in a significant portion of patients who subsequently 236
meet the criteria for myocardial infarction. Pericarditis or prior myocardial infarction with aneurysm formation can cause ECG changes similar to those in acute myocardial infarction; the examination of subsequent ECGs in the former case and comparison with previous ECGs in the latter may help with differential diagnosis. The presence of pre-existing left bundle branch block (LBBB) results in baseline repolarization abnormalities that limit the utility of ECG in the diagnosis of acute myocardial infarction in these patients. Although a number of criteria have been proposed to discern indicators of acute myocardial infarction within the LBBB morphology,[10] these criteria have been found to be insensitive in the diagnosis of acute myocardial infarction.[11] Determination of serum cardiac enzyme levels constitutes a more sensitive and specific test.[12] However, serum cardiac enzyme levels may not be elevated until several hours after the onset of myocardial infarction; therefore, sole reliance on this method may delay starting appropriate treatment. Echocardiography can be a useful adjunct in the assessment of patients with chest pain. By evaluating global ventricular function as well as regional wall motion, echocardiography may allow the early diagnosis of myocardial ischemia and infarction, as well as determination of the coronary vascular territory involved. It is also useful in the differential diagnosis of acute chest pain by excluding such possibilities as aortic dissection, effusive pericarditis, and aortic stenosis among other conditions (Table 11-1) ; these topics are covered in greater detail in their respective
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 3
chapters in this book. In the remainder of this chapter, we concentrate on the current and developing applications of echocardiography to the early diagnosis of acute coronary syndromes, as well as their advantages, limitations, and potential impact on patient management and outcome.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/90.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Echocardiography and the Physiology of Acute Ischemia Acute ischemia results in a cascade of biochemical and physiologic changes in myocardial tissue.[13] When coronary flow is cut off, biochemical changes are quickly followed by abnormalities in diastolic and then systolic function. Moreover, these functional changes may precede development of classic electrocardiographic changes or even development of symptoms[14] and occur well before release of detectable amounts of enzyme markers such as creatine kinase and troponin. Thus, development of systolic regional wall motion abnormalities such as those TABLE 11-1 -- Goals of Echocardiography in Evaluation of Patients with Acute Chest Pain Diagnosis of acute coronary syndrome Determination of coronary vascular territory involved Assessment of the area of myocardium at risk Evaluation of global ventricular function Exclusion of other cardiac causes of chest pain Aortic dissection Pericarditis (with effusion) Aortic stenosis Hypertrophic cardiomyopathy detected by echocardiography occurs at a relatively early stage after onset of ischemia. This has led to considerable interest in the use of echocardiography to aid in the diagnosis and prognosis of acute coronary syndromes and in defining the coronary territory involved.
MD Consult L.L.C. http://www.mdconsult.com
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 5
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Technical Aspects of Echocardiography in the Emergency Department Image Acquisition Echocardiographic examination of patients with chest pain in the emergency room should concentrate on the evaluation of biventricular function and global and regional left ventricular wall motion to look for evidence of cardiac ischemia or infarction. It should also screen for other possible nonischemic causes of chest pain such as aortic stenosis, hypertrophic cardiomyopathy, effusive pericarditis, and aortic dissection. The standard transthoracic two-dimensional echocardiographic views should be used for evaluation of all the left ventricular wall segments, including parasternal long-and short-axis, apical long-axis, and apical twoand four-chamber views (Fig. 11-1) . If adequate image quality cannot be achieved from the apex, subcostal four-chamber and short-axis views or parasternal short-axis views with the transducer moved more apically may be acquired instead. Off-axis or oblique views make interpretation of regional wall motion abnormalities more difficult and should be avoided. A well-trained and experienced sonographer or echocardiographer is essential in such a clinical setting. The sonographer should be trained to obtain the required images in an efficient manner, avoiding spending time on aspects of the examination not needed for immediate clinical use. Attention should be paid to proper patient positioning, use of appropriate transducers, and adjustment of machine settings. High-frequency transducers may improve the visualization of apical structures. In obese patients or those with chronic obstructive pulmonary disease, lowerfrequency (2.0 to 2.5 MHz) transducers and a subcostal window may be used to optimize the images. Colorization of two-dimensional echocardiographic images and, more recently, echo contrast have also been used to enhance visualization of the endocardial border.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 5
Optimization of endocardial border definition is of utmost importance. In addition to the standard techniques mentioned, newer imaging modalities such as second harmonic imaging and contrast echocardiography can be used for this purpose. Commercially available echocardiographic contrast agents contain air-filled microbubbles which are small enough to pass through the pulmonary circulation after intravenous administration. They opacify both ventricular cavities, allowing the border between myocardium and blood to be more easily identified (Fig. 11-2) . This technique is especially effective when combined with second harmonic imaging, which also improves the visualization of other cardiac structures.
237
Figure 11-1 Still frames from the echocardiogram of a patient with acute chest pain, showing severe hypokinesis of the anterior, septal, and apical walls, in parasternal short-axis (A, diastole; B, systole) and apical fourchamber (C, diastole; D, systole) views.
238
Figure 11-2 Improvement in left ventricular endocardial border delineation with the use of intravenous echocardiographic contrast and second harmonic imaging (A, without contrast; B, with echocardiographic contrast).
In an early study by Horowitz et al[15] on the use of echocardiography in patients with acute chest pain, adequate images were obtained in 81% of the patients. A large, multicenter study performed in Denmark in the early 1990s involving 7001 patients early after an acute myocardial infarction reported assessable echocardiograms in 93% of the patients.[16] With continual advances in echocardiographic technology since that time, one can expect to obtain adequate echocardiograms in an even larger proportion of patients. Stress Echocardiography Multiple studies have demonstrated the safety of stress testing if myocardial infarction and unstable angina are ruled out after several hours
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 5
of observation. Echocardiographic imaging may be used in conjunction with exercise or pharmacologic stress to assess for ischemia, depending on the patient's ability to perform adequate exercise. For exercise stress, one of the standard treadmill exercise protocols, such as the Bruce or modified Bruce protocol, can be used. Because wall motion abnormalities associated with exercise may be ephemeral after treadmill exercise terminates, echocardiographic examination should start within a few seconds after exercise terminates. This helps avoid significant decrease in heart rate below the maximum achieved, which may have an impact on the sensitivity of the test. An alternative exercise method is the supine bicycle protocol. A patient in a supine position exercises on a specially designed bicycle mounted on the echocardiographic examination table. The amount of energy spent increases with each 3-minute exercise stage. In this approach, echocardiographic images can be acquired during exercise, thereby eliminating the delay seen with treadmill exercise between the cessation of exercise and the start of imaging. In addition, images can be recorded at low, medium, and peak levels of exercise stress for comparison in this protocol, whereas only preand poststress images are generally recorded for treadmill protocols. The supine bicycle exercise protocol is preferred if spectral Doppler echocardiographic measurement of tricuspid regurgitation velocity is required for estimation of pulmonary artery systolic pressure. For patients unable to achieve adequate levels of exercise, pharmacologic stress testing can be performed. The intravenous dobutamine protocol is most commonly used in the United States. After acquisition of baseline resting echocardiographic images, dobutamine infusion is generally started at 5 µg/kg/minute, and increased to 10, 20, 30, and 40 µg/kg/minute at each successive stage of 3-minute duration. The test is terminated if the patient develops evidence of cardiac ischemia, hypotension as a result of vasodilation or left ventricular outflow obstruction, significant arrhythmia, or other dobutamine-related side effects or if 85% of maximum predicted heart rate is achieved. In patients who do not achieve adequate heart rate with dobutamine infusion at 40 µg/kg/minute, such as those taking beta blockers, atropine may be administered intravenously with doses of 0.1 to 0.25 mg each, up to a total of 1 mg. Second harmonic imaging has also been found to improve endocardial border definition, diagnostic accuracy,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 5
239
and interobserver agreement for dobutamine stress echocardiography in patients with impaired image quality. In a study by Franke et al,[17] second harmonic imaging without use of echocardiographic contrast increased the sensitivity for the diagnosis of coronary artery disease in patients with poor image quality from 64% to 92% (P < .001). Specificity was 75% for both imaging modalities. Improvement in endocardial border delineation was most pronounced in all lateral and anterior segments. Image Interpretation The accurate interpretation of regional wall motion abnormalities requires an experienced echocardiographer. Using various views from the study, wall thickening and systolic endocardial motion are evaluated for all left ventricular myocardial segments. Each segment is classified as hyperkinetic, normal, hypokinetic, akinetic, or dyskinetic. The American Society of Echocardiography recommends a 16-segment model for evaluation of regional wall motion (Fig. 11-3) .[18] Each segment is assigned a score on the basis of visual inspection of its contractility: normal, 1; hypokinesis, 2; akinesis, 3; dyskinesis 4; and aneurysm, 5. A semiquantitative measure of the extent of regional wall motion abnormalities, known as the wall motion score index (WMSI), can be calculated by averaging wall motion scores for all visualized segments. A normal left ventricle has a WMSI of 1, while a ventricle with more significant left ventricular dysfunction would have a higher WMSI. WMSI has been found to relate to infarct size on clinicopathologic studies[19] and to perfusion defect size on single photon emission computed tomographic (SPECT) imaging.[20] A similar wall motion index using a 14-segment model has also been found to be a predictor of long-term survival in patients with chest pain.[21] The evaluation of stress-induced regional wall motion abnormalities in stress echocardiography requires careful comparison of rest and stress images, which is facilitated by digital acquisition and display of such images. ECG-gated digital acquisition allows video clips lasting one to several cardiac cycles to be captured and stored in memory. Thus, several clips can be acquired and the most satisfactory one for each view selected for repeated comparative display. Comparison of rest and stress images from each view is facilitated by the use of side-by-side quad-screen display of synchronized cineloops. Digital image acquisition and display in stress
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 5
echocardiography have been found to have comparable diagnostic accuracy for coronary artery disease to videotape recording, and superior interobserver and intraobserver agreement.[22] [23] Mohler et al[24] compared digital echocardiographic images with videotape images in a prospective study involving 117 patients admitted to the emergency department with chest pain and found 94% overall agreement regarding regional wall motion and good correlation in WMSI determined using these two different technologies. The authors concluded that digital echocardiographic imaging provides an accurate summary of the complete examination, as well as relevant diagnostic data for assessment of Figure 11-3 A 16-segment model for evaluation of regional wall motion as recommended by the American Society of Echocardiography. A, anterior; AL, anterolateral; AS, anteroseptal; I, inferior; IL, inferolateral; IS, inferoseptal; PL, posterolateral; PS, posteroseptal. (Adapted from Schiller NB, Shah PM, Crawford M, et al: J Am Soc Echocardiogr 1989;2:358–367.)
patients presenting with chest pain to the emergency department.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/92.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 8
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Clinical Applications Triage of Patients with Chest Pain in the Emergency Department A number of studies have assessed the use of two-dimensional transthoracic echocardiography or stress echocardiography in evaluating patients presenting with chest pain and suspected acute coronary syndrome. [15] [25] [26] [27] [28] [29] [30] [31] [32]
Horowitz et al[15] studied 80 patients who presented with acute chest discomfort to the emergency department and had no previous myocardial infarction, valvular heart 240
disease, cardiomyopathy, or significant pericardial effusion. Twodimensional echocardiography was performed within 8 hours of admission. Locations of regional wall motion abnormalities were described using a five-segment model, with septal, anterior, posterolateral, posterior, and apical segments. The echocardiograms were technically inadequate in 15 patients (19%) in this study performed in the early 1980s. Of the 33 patients with clinical evidence of myocardial infarction, 31 had regional wall motion abnormalities on the initial echocardiogram (sensitivity, 94%). The other 2 patients had uncomplicated nontransmural myocardial infarctions. In comparison, the initial ECG was diagnostic of acute myocardial infarction in 45%, and the initial creatine kinase-MB level was elevated in 52%. Of the 32 patients without clinical myocardial infarction, 27 had normal regional wall motion on the initial echocardiogram (i.e., specificity, 84%). It is noteworthy that none of the patients with normal regional wall motion on the initial echocardiogram had an in-hospital clinical complication. In the late 1980s, Sabia et al performed a prospective study using two-
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 8
dimensional echocardiography in 180 consecutive patients who presented to the emergency department with symptoms suggestive of acute myocardial infarction.[27] [33] The echocardiographic findings were not utilized in actual patient management but in assessing the diagnostic accuracy and cost of an alternate management scenario. The echocardiograms were technically inadequate in 6%. Regional wall motion was assessed using a 12-segment model. Among the 30 patients with acute myocardial infarction, 9 had ST-segment elevation on ECG (sensitivity, 30%), 3 had normal ECGs, 8 had ECGs with LBBB, paced rhythm, or other baseline repolarization abnormalities that make the diagnosis of acute myocardial infarction impossible, and 10 had nonspecific ECG findings. Twenty-nine of these 30 patients with acute myocardial infarction had technically adequate echocardiographic studies. Twenty-seven had regional wall motion abnormalities (sensitivity, 90%). Among the 13 patients with in-hospital complications, all had regional wall motion abnormalities on the initial echocardiogram, whereas only 4 had ST-segment elevation on the initial ECG. Sabia et al proposed an alternate scenario for the management of patients who present to the emergency department with possible acute myocardial infarction.[33] Those with acute ST-segment elevation on ECG would be admitted to the coronary care unit. The others would undergo twodimensional echocardiography. If the study was technically inadequate, admission to the hospital would be decided using conventional criteria. For patients with technically adequate studies, those with regional wall motion abnormalities would be admitted to the hospital, and those with normal wall motion or with global dysfunction would be discharged. If this scenario is applied to the set of study patients, hospital admissions are reduced by 32% (coronary care unit admissions by 25%, and non-coronary care unit admissions by 41%), total hospital stay for all patients is reduced by 23%, and estimated total cost is 24% lower. Under this scenario, two patients with small acute myocardial infarctions and no complications would be sent home. In comparison, two patients with larger acute myocardial infarctions were sent home using the conventional criteria and one of them had a complication after acute myocardial infarction (complete heart block requiring permanent pacemaker). The authors concluded that two-dimensional echocardiography is superior to conventional criteria in the diagnosis of patients with suspected acute myocardial infarction in the prediction of in-hospital complications and in reducing hospital admissions and total cost. This conclusion would be strengthened by further prospective validation in a different cohort of patients.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 8
Use in Chest Pain Centers and Clinical Algorithms Specialized chest pain centers have been established to evaluate patients presenting with acute chest pain with published studies describing clinical outcome in patients treated according to a chest pain algorithm.[34] For example, Gibler and coworkers published results from their "Heart ER Program," a diagnostic and treatment program for patients with chest pain in an urban tertiary care emergency department.[35] Their initial evaluation algorithm is summarized in a flow diagram in Figure 11-4 . A total of 1010 patients with symptoms suggestive of acute coronary syndrome were enrolled over a 32-month period. Patients with known coronary artery disease, acute ST-segment elevation or depression of greater than 1 mm, hemodynamic instability, or clinical presentation consistent with unstable angina were directly admitted to the hospital. Other patients were entered into the 9-hour evaluation program during which creatine kinase-MB levels were checked on presentation and every 3 hours afterwards for three times and 12-lead ECG or ST-segment was continuously monitored. After the 9hour evaluation period, two-dimensional echocardiography and graded exercise testing were performed in the emergency department and used to reach discharge decisions. Of the 1010 patients, 829 (82.1%) were discharged from the emergency department, and 153 (15.1%) were admitted to the hospital for further evaluation. Among the 153 admitted patients, 52 (33.9%) were found to have a cardiac cause for their symptoms; 43 (28.1%) had acute coronary syndrome (12 with acute myocardial infarction, 31 with myocardial ischemia). The authors concluded that the "Heart ER Program" provides an effective approach for evaluation of low- to moderate-risk patients with possible acute coronary syndrome in the emergency department. Trippi et al[28] reported a clinical trial using dobutamine stress echocardiography for evaluation of patients presenting with chest pain to the emergency room to determine who can be safely discharged from the emergency department. The echocardiograms were digitized for electronic transmission according to their tele-echocardiography protocol. One hundred sixty-three patients with negative results on initial ECGs and blood studies who were recommended for hospital admission to rule out myocardial infarction or ischemia were evaluated. Rest echocardiography was performed in the emergency room and transmitted to an interpreting cardiologist. If the echocardiogram
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 8
241
Figure 11-4 Chest pain evaluation algorithm used in the Heart ER Program by Gibler and coworkers. ECG, electrocardiographic; CAD, coronary artery disease; CK-MB, creatine kinase-MB; 2D, twodimensional. (Data from Gibler WB, Runyon JP, Levy RC, et al: Ann Emerg Med 1995;25:1–8.)
was normal, dobutamine stress echocardiography was performed by a trained nurse, with images again transmitted to the cardiologist. The test was completed within an average of 5.4 hours after presentation to the emergency room. Using clinical follow-up data and cardiac catheterization as the gold standard, the authors determined the sensitivity of the test to be 89.5%, the specificity 88.9%, and the negative predictive value 98.5%. In a later phase of the trial, patients with normal dobutamine stress echocardiography were released from the hospital; these constituted approximately 72% of the patients. Assessment of the Need for Urgent Coronary Angiography Coronary angiography is generally regarded as the gold standard in the diagnosis of coronary artery disease. In patients with a nondiagnostic ECG and a high pretest probability of coronary artery disease, clinicians can elect to have patients proceed directly to coronary angiography, possibly followed by percutaneous coronary interventions. This modality yields accurate information of coronary anatomy and may lead to prompt revascularization, which improves myocardial salvage and survival in patients with acute coronary artery occlusion. It does not directly provide information on the functional significance of the coronary artery stenoses, which can only be inferred from the location and severity of stenosis. Echocardiography can assist in the decision concerning the need for urgent coronary angiography. Normal global and regional wall motion may persuade the clinician to take a more conservative approach, with later stress testing to rule out significant coronary artery disease. The finding of a new wall motion abnormality, however, may prompt more urgent coronary angiography and intervention. Risk Stratification and Analysis of Long-Term Clinical Outcome Various diagnostic tests have been studied for their prognostic value in the treatment of patients with acute coronary syndrome. Savonitto et al [36]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 8
performed a retrospective analysis of the presenting ECGs of patients enrolled in the Global Utilization of Strategies To Open 242
Occluded Arteries in Acute Coronary Syndromes (GUSTO-IIb) study and found the 30-day incidence of death or myocardial reinfarction to be 5.5% in patients with T-wave inversion, 9.4% in patients with ST-segment elevation, 10.5% in patients with ST-segment depression, and 12.4% in patients with ST-segment elevation and depression (P < .001). Compared with those who had T-wave inversion only, the odds ratios (OR) of 30-day death or reinfarction remained higher for those with ST-segment elevation (OR, 1.68; 95% confidence interval [CI], 1.36–2.08), for those with STsegment depression (OR, 1.62; 95% CI, 1.32–1.98), and for those with STsegment elevation and depression (OR, 2.27; 95% CI, 1.80–2.86) after multivariate adjustment for other risk factors. Initial elevation in creatine kinase level is also associated with greater risk of death and reinfarction, as is elevation in serum troponin levels. [37] [38] [39] A number of studies have demonstrated the incremental utility of echocardiography, beyond clinical assessment and electrocardiography, in predicting clinical outcome of patients with acute chest pain.[40] [41] In a prospective study involving 466 visits to a large urban emergency department by patients with acute chest pain, Fleischmann et al[40] examined echocardiographic predictors of serious predischarge complications in patients with chest pain. Doppler echocardiograms were performed an average of 21 hours after presentation and used to assess global biventricular function, regional wall motion, and valvular disease. Regional wall motion was assessed using a wall motion index on the basis of a 14segment model. The composite complications end point included significant recurrent myocardial ischemia, heart failure, or arrhythmia. In univariate analysis, the following variables predicted complications: left ventricular function (OR, 2.9; 95% CI, 1.6–5.1), right ventricular function (OR, 2.7; 95% CI, 1.2–6.2), left ventricular end-diastolic dimension Figure 11-5 Kaplan-Meier survival curves for patients presenting with chest pain stratified by left ventricular function. LVD, left ventricular dysfunction. (From Fleischmann KE, Lee RT, Come PC, et al: Am J Cardiol 1997;80:1266–1272, with permission from Excerpta Medica Inc.)
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 8
(OR, 1.6/cm; 95% CI, 1.1–2.3), left ventricular end-systolic dimension (OR, 1.4/cm; 95% CI, 1.1–1.9), and wall motion index (OR, 3.0; 95% CI, 1.8–4.8). In multivariate analysis, wall motion index remained an incremental predictor of subsequent complications beyond clinical and electrocardiographic variables. In a companion study involving 448 patients, the long-term survival of these patients was examined.[21] The follow-up period was 35.0 ± 12.1 months. In univariate Cox regression analysis, left ventricular function and size, wall motion index, right ventricular function, and aortic, mitral, and tricuspid regurgitation were significant predictors of total and cardiovascular mortality. In multivariate analysis involving a model adjusted for clinical and electrocardiographic data, the following were found to be independent predictors of mortality: moderate or severe left ventricular dysfunction (mortality rate ratio, 3.2; 95% CI, 1.8–5.8), and more than mild valvular regurgitation (mortality rate ratio, 2.0; 95% CI, 1.1–3.6). These two echocardiographic findings offer incremental prognostic value over clinical and ECG information alone in patients presenting with acute chest pain syndrome. Kaplan-Meier survival curves for these patients stratified by left ventricular function and by the grade of mitral regurgitation are shown in Figure 11-5 and Figure 11-6 , respectively. Chuah et al,[42] from the Mayo Clinic, examined the incremental utility of dobutamine stress echocardiography over clinical and rest echocardiographic variables in predicting outcome in a cohort of 860 patients with known or suspected coronary artery disease. The patient population in this study was not restricted to patients presenting to the emergency room with chest pain. Semiquantitative evaluation of regional wall motion was performed using the WMSI on the basis of the 16-segment model of the American Society of Echocardiography. The patients were followed for up to 52 months. End points consisted 243
Figure 11-6 Kaplan-Meier survival curves for patients presenting with chest pain stratified by grade of mitral regurgitation (MR) (on a 4+ scale). (From Fleischmann KE, Lee RT, Come PC, et al: Am J Cardiol 1997;80:1266–1272, with permission from Excerpta Medica Inc.)
of cardiac death and myocardial infarction. Seventy-two patients underwent
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 8
coronary artery revascularization before any cardiac event during the follow-up period and were censored. Nonfatal myocardial infarction occurred in 36 patients, and cardiac death in 50 patients. Using a stepwise Cox multivariate regression model involving clinical and rest and stress echocardiographic data, the following were found to be independent predictors of cardiac events: a history of congestive heart failure (hazard ratio, 2.51; 95% CI, 1.54–4.07), the percentage of abnormal segments at peak stress (hazard ratio, 1.14; 95% CI, 1.05–1.23), and an abnormal left ventricular end-systolic volume response to stress (Hazard ratio, 1.98; 95% CI, 1.14–3.46). The model that incorporated clinical and stress echocardiographic data was found to be the best at predicting subsequent cardiac events. Evaluation of Other Causes of Chest Pain Although determination of global systolic function and regional wall motion is of paramount importance in the evaluation of patients presenting with acute chest pain to the emergency department, rapid screening for certain other causes of chest pain should not be neglected, especially in those patients whose presentation appears atypical for ischemic chest pain. Aortic dissection is potentially life-threatening and may be seen on transthoracic echocardiogram, although sensitivity is limited, precluding its use as a first-line imaging technique to exclude dissection. Evidence of an intimal flap may be seen in the aortic root and proximal ascending aorta on the parasternal long-axis view, in the aortic arch on the suprasternal view, and in the descending abdominal aorta on the subcostal view (Fig. 11-7) . The descending thoracic aorta cannot be adequately examined on a transthoracic study, however. In a series of 67 patients from the Mayo Clinic, the sensitivity of transthoracic echocardiogram was 79%, and the positive predictive value was 91%.[43] Transesophageal echocardiography Figure 11-7 Suprasternal view from a transthoracic echocardiogram demonstrating an aortic dissection involving the aortic arch and the ascending aorta.
244
(TEE; especially multiplane) is a more sensitive and specific technique for
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 8
examination of the thoracic aorta and should be performed if there is clinical suspicion of aortic dissection. Effusive pericarditis can be easily diagnosed, and the size of the pericardial effusion can be assessed on the transthoracic echocardiogram. The subcostal window is especially useful for this purpose even in patients in whom poor image quality is achieved on parasternal or apical views. The potential hemodynamic consequences of the pericardial effusion may be evaluated with examination of right heart chambers for collapse, Doppler echocardiography of mitral and tricuspid inflow velocities, and twodimensional examination of the inferior vena cava and its variation in size with inspiration. If pericardiocentesis is desired for diagnostic or therapeutic purposes, echocardiographic guidance can facilitate safe performance of the procedure. [44] [45] [46] [47] Rapid screening for aortic stenosis can be made with Doppler measurement of transaortic valvular flow velocity and two-dimensional examination of calcification and motion of the aortic valve leaflets. Similarly, assessment for echocardiographic evidence of hypertrophic obstructive cardiomyopathy can be made with measurement of septal thickness, detection of systolic anterior motion of the mitral valve leaflet, and Doppler echocardiographic measurement of a significant gradient in the left ventricular outflow tract.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/93.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 4
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Cost-Effectiveness Analysis Rapid advances in science and technology in the past century have improved the quality of health care and have also resulted in a great increase in health care costs. This development has generated increasing interest in applying the techniques of cost-effectiveness analysis to evaluate preventive, diagnostic, and therapeutic strategies in medicine. Table 11-2 lists key terms used in cost-effectiveness analysis. In formal cost-effectiveness analysis, cost is expressed in terms of monetary units, and effectiveness is expressed in units such as the number of lives saved, the years of life saved, the days of disability avoided, and so on. [48] To analyze difficult and complex clinical problems for which no clear consensus exists among experts, a clinical decision model may be constructed to outline explicitly various diagnostic or therapeutic options, and the possible clinical events and outcomes. Probabilities for various clinical events and outcomes can be estimated on the basis of the best available current evidence from the medical literature or, if this is not available, from the physicians' clinical judgment. Each possible outcome is assigned a cost and a utility. By convention, perfect health is assigned a utility value of 1, and death is assigned a value of 0. Various schemes have been devised to assign utility values to different degrees of disease or symptom severity. Thus, cost and health benefit can be calculated for the various options under consideration. The conclusions drawn from any type of clinical decision analysis can only be as accurate as the assumptions on which the model is based. In cases in which the TABLE 11-2 -- Key Terms in Cost-Effectiveness Analysis Cost: amount of resource required, usually expressed in monetary units. Effectiveness: health benefit achieved, commonly expressed in units such as the number of lives saved, the days of disability avoided, the years of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 4
life saved, and so on. Clinical decision model: a model of the clinical problem, usually constructed in the form of a decision tree, in which various diagnostic or therapeutic options are outlined, and the possible clinical events and outcomes are enumerated and assigned probabilities and utilities. This can be used to analyze the cost or health benefit of various options. Utility: the benefit associated with a specific outcome. By convention, perfect health is assigned a value of 1, and death is assigned a value of 0. Sensitivity analysis: an analysis in which certain parameters in the clinical decision model are systematically varied over reasonable ranges, so as to determine whether the results of the model are significantly affected. This is especially important if there is significant uncertainty or variability in the values of certain parameters. QALY: quality-adjusted life-year. Incremental cost-effectiveness: additional cost-effectiveness of a new strategy compared with the baseline strategy. parameters in the model can vary over a certain range or in which there is uncertainty regarding their values, it is critical to determine whether variation of parameter values over reasonable ranges significantly affects the results of the analysis. This process is referred to as sensitivity analysis. Given the results of a cost-effectiveness analysis, the decision about whether it is worthwhile to spend a certain additional amount to achieve an incremental benefit will depend on the society's values and socioeconomic conditions. In many analyses of health care delivery in the United States, the cost of renal dialysis (approximately $35,000 to $40,000 per patient per year in 1995) is often used as the benchmark for the cost that the American public is willing to bear to prolong life by 1 year. Data on the cost-effectiveness of echocardiography in patients presenting to the emergency department with acute chest pain are scarce. In more general cost-effectiveness analyses of diagnostic strategies for patients with chest pain, most studies have found the preferred initial strategy to be noninvasive testing for patients with low to intermediate pretest probability of coronary artery disease, and coronary angiography for those with high pretest probability. In a study by Kuntz et al,[49] exercise echocardiography cost $41,900 per quality-adjusted life-year (QALY) saved compared with exercise electrocardiography for 55-year-old men with atypical angina.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 4
Exercise SPECT cost $54,800 per QALY saved compared with exercise electrocardiography for these patients. The incremental cost-effectiveness ratio of routine coronary angiography compared with exercise echocardiography was $36,400 per QALY saved for 55-year-old men with typical angina. For 55-year-old men with nonspecific chest pain, the incremental cost-effectiveness ratio of exercise electrocardiography compared with no testing was $57,700 per QALY saved. The authors concluded that exercise electrocardiography or exercise echocardiography resulted in reasonable cost-effectiveness ratios for patients 245
at mild to moderate risk for coronary artery disease in terms of age, sex, and type of chest pain. Garber and Solomon analyzed the cost-effectiveness of five test strategies for patients with a history of chest pain and intermediate pretest probability (25% to 75%) of coronary artery disease.[50] These strategies involved a noninvasive test (treadmill exercise testing, planar nuclear imaging, SPECT, stress echocardiography, or positron emission tomography) followed by coronary angiography if the noninvasive test was positive. Using information from published literature on the sensitivity and specificity of each test, disease prevalence, and treatment efficacy, and basing cost calculations on Medicare payments, the authors developed a decision analytic model to assess the health outcomes and costs of the different strategies. They found that stress echocardiography improved health outcomes and reduced costs relative to exercise stress testing and planar nuclear imaging. The incremental cost-effectiveness ratio was $75,000 per QALY for SPECT relative to echocardiography, more than $640,000 per QALY for positron emission tomography relative to SPECT, and $94,000 per QALY for immediate coronary angiography relative to SPECT. The authors concluded that stress echocardiography, stress SPECT, and immediate coronary angiography are cost-effective alternatives to positron emission tomography and other strategies. Exercise treadmill testing for assessment of chest pain or risk stratification has been found to be cost-efficient even if greater expense is incurred when such tests are performed outside of regular laboratory hours. Krasuski et al [51] studied 195 patients scheduled for exercise stress testing during weekends or holidays for assessment of chest pain (75%) and other indications; the study population was not limited to chest pain patients from
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 4
the emergency department. The authors found the approach to be safe and effective for risk stratification and to shorten hospital stay. Although a formal cost-effectiveness analysis was not performed in this study, this approach was found to result in cost savings even when the greater expenses associated with testing during weekends or holidays were taken into consideration. For a general discussion of cost-effectiveness analysis for noninvasive diagnostic testing for coronary artery disease, refer to the paper by Hunink et al.[52]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/94.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Limitations Limitations in the Use of Regional Contractile Function to Evaluate Ischemia Evaluation of acute coronary syndrome with echocardiography has several limitations. Between episodes of cardiac ischemia, the patient's wall motion may be completely normal. Therefore, a normal resting echocardiogram performed in such a patient cannot rule out cardiac ischemia as the cause of the patient's symptoms. Stress testing should be considered after myocardial infarction is ruled out. The presence of pre-existing left ventricular dysfunction secondary to nonischemic cardiomyopathy or valvular heart disease makes the evaluation of new regional wall motion abnormalities more difficult and may cause the specificity of this technique to be lower for this population of patients. Image Quality The detection of regional wall motion abnormalities requires adequate visualization of endocardial borders. In patients with morbid obesity, chest wall deformity, chest trauma, or recent thoracic surgery, views with good image quality may be difficult to acquire, especially given the time constraints imposed by the need for rapid diagnosis and institution of therapy. The use of newer echocardiographic modalities, such as second harmonic imaging with echocardiographic contrast administration, may improve endocardial border delineation in such patients and make echocardiographic evaluation in the emergency department more practical. Personnel Availability Ready availability of sonographers to perform echocardiographic examinations and echocardiographers to interpret them is essential if
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
echocardiography is to enjoy more widespread use in the evaluation of patients with chest pain in the emergency department. This is not a problem during usual working hours in most hospitals. However, it may not be economically practical to have the personnel physically "on call" in the hospital 24 hours a day for most community hospitals or even tertiary medical centers. Contacting sonographers and echocardiographers on call outside of the hospital inevitably causes a delay in the management of such patients. One approach to deal with this problem is to train emergency department personnel to perform echocardiograms. An obstacle to successful implementation of this approach is the difficulty in gaining and maintaining sufficient experience in performing echocardiographic studies in the context of the rotating shift system in most emergency departments. This logistical problem may be at least partially solved with the advent of digital tele-echocardiography systems. Acquired images can be transmitted over a high-speed network to an experienced echocardiographer outside the hospital for immediate interpretation. Future systems may incorporate the capability for greater real-time interaction between the off-site interpreting physician and the on-site sonographer to ensure the acquisition of all requisite images for any particular clinical situation.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/95.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Future Developments Tele-echocardiography The accurate interpretation of stress echocardiographic images requires experienced echocardiographers, who may not be immediately available in the hospital during off-hours. Having an experienced echocardiographer available in the hospital 24 hours a day or to come into 246
the hospital when such cases occur may not be practical in many hospitals. In addition, the latter option may further delay definitive treatment. Electronic transmission of echocardiographic images has been used as part of telemedicine projects in a number of centers. In nonemergency settings, successful use has been reported in the difficult diagnostic cases requiring expert interpretation, such as patients with congenital heart disease.[53] [54] [55] In the clinical trial by Trippi et al[28] using dobutamine stress echocardiography to determine which patients presenting with chest pain to the emergency room may be safely discharged, the echocardiograms were digitized into a quad-screen systolic eight-frame cineloop format with resolution of 320 by 240 pixels, and transmitted to the interpreting physician over the standard telephone line using a proprietary "lossless" format developed before DICOM standards.[56] [57] The test was completed within an average of 5.4 hours after presentation to the emergency room. It was found to have very good sensitivity and specificity and could potentially result in significant cost savings, as discussed previously in the section on Clinical Applications. Rapid technologic developments since that time, including faster processor speed, availability of higher capacity random access memory, and faster network connections via the Internet or dedicated lines may result in more
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
widespread use of this technology. Of course, the transmission of patientspecific data over publicly accessible networks will require proper encryption to ensure patient privacy. Myocardial Contrast Echocardiography The use of echocardiographic contrast with second harmonic imaging to evaluate myocardial perfusion is one of the most exciting developing areas of echocardiography. Ultrasonographic imaging for this purpose needs to be intermittent so as to minimize the destruction of micro-bubbles in the contrast agent. This technique, when perfected, has potential uses in the diagnosis of acute myocardial infarction, determination of ischemic and infarcted areas in conjunction with stress testing, evaluation of reperfusion status, detection of no reflow in the microvascular coronary circulation after restoration of flow in the epicardial coronary arteries, and evaluation of myocardial viability. Although promising, this echocardiographic technique needs to be further refined before its utility in the examination of patients with acute chest pain syndrome can be evaluated. Other Modalities Doppler tissue imaging[58] [59] [60] and color kinesis[61] [62] (Fig. 11-8) are two of the promising new imaging modalities, although further studies are needed to determine their utility in routine assessment of regional wall motion.
MD Consult L.L.C. http://www.mdconsult.com /das/book/view/26070721/1031/96.html/top Bookmark URL:
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 3
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Chest Pain Centers Centers dedicated to diagnostic evaluation of patients presenting with chest pain suggestive of acute coronary syndrome have been set up in a number of medical centers in the United States, with the goal of improving the efficiency of evaluation while preserving or improving outcomes.[2] [34] [63] Most chest pain centers are based within the emergency department or in an adjacent observation unit. Others are located in a part of an inpatient telemetry unit. Patients presenting to the emergency department with chest pain are first stratified into several risk groups on the basis of their history, physical examination, and initial 12-lead ECG. High-risk patients, including those with significant acute ST-segment changes, hemodynamic instability, and known history of coronary artery disease, are admitted directly, usually to the coronary care unit. Those with acute ST-segment elevation or new LBBB will receive reperfusion therapy with thrombolytic agents or cardiac catheterization. Patients with low to moderate pretest probability of acute coronary syndrome, who have no contraindications to diagnostic testing according to the chest pain center protocol and no serious comorbid conditions that may interfere with discharge from the emergency department, are evaluated further in the chest pain center. Other low- to moderate-risk patients may be admitted to a step-down telemetry unit for further evaluation. Patients with noncardiac chest pain are treated and triaged according to their diagnosis. Although individual protocols vary, patients in the chest pain center often undergo serial cardiac enzyme marker determinations (e.g., at 0, 3, and 6 hours after presentation). Serial 12-lead ECGs or continuous ST-segment monitoring is also performed. The monitoring period generally ranges from 6 to 12 hours, although an experience with immediate stress testing in lowrisk patients has also been reported. [64] [65] Patients who develop evidence of acute coronary syndrome during the period of monitoring are admitted. The
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 3
rest will undergo further diagnostic testing after the monitoring period for diagnosis of coronary artery disease and for risk stratification. A number of studies address possible choices for diagnostic testing in emergency department patients presenting with chest pain.[27] [28] [35] , [41] [66] [67] [68] [69] Graded exercise ECG testing is often obtained for those patients who can exercise to an adequate level, have no contraindications to exercise testing, and have no baseline ECG abnormalities that may interfere with the interpretation of stress ECGs. Exercise or pharmacologic stress imaging can be utilized in other patients. The incremental value and costeffectiveness of imaging for patients being evaluated in chest pain centers who can exercise requires further study, as suggested by the American Heart Association.[70] Stress testing is usually supervised by an appropriately trained physician and performed in a dedicated area with resuscitative equipment available and should conform to American Heart Association guidelines for exercise ECG laboratories.[70] [71] As mentioned in an earlier section, accurate acquisition and interpretation of stress echocardiograms requires an experienced sonographer and echocardiographer. Thus, the chest pain center performing stress echocardiography will need a physician experienced in echocardiography to be available on call in or near the hospital, unless tele-echocardiography equipment is available to transmit images to the interpreting physician. Patients 247
Figure 11-8 (color plate.) Tissue Doppler imaging (TDI; top) and myocardial velocity gradient (MVG; bottom) images of the left ventricle in the parasternal short-axis view from a patient with left anterior descending coronary artery obstruction: at baseline (left), with low-dose (10 µg/kg/min) dobutamine (middle), and with high-dose (30 µg/kg/min) dobutamine (right). In the TDI images, the anteroseptal wall is color-coded blue because it is moving away from the transducer during systole. Similarly, the posterior wall is color-coded red because it is moving toward the transducer. MVG is derived from TDI, and it is defined as the slope of the regression line of the intramyocardial velocity profile across the myocardium. It reflects regional wall thickening and has been shown to be independent of the translational motion of the heart. In the MVG images, thickening of the myocardium is color-coded red, and thinning of the myocardium is color-coded blue. Calculated segmental MVGs are shown beside the corresponding segments. In this patient, MVG undergoes a dose-responsive increase in the posterior segment and no significant change in the anteroseptal segment supplied by the diseased coronary artery. (From Tsutsui H, Uematsu M, Shimizu H, et
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 3
al: J Am Coll Cardiol 1998;31:89–93. Reprinted with permission from the American College of Cardiology.)
with positive stress tests will usually be admitted for further evaluation; those with negative evaluations will generally be discharged from the chest pain center with careful attention to adequate outpatient follow-up. An important part of the work of a successful chest pain center involves community outreach to increase public awareness of the importance of seeking prompt medical attention for chest pain. This will further improve the clinical outcome of patients presenting to the emergency department with acute coronary syndrome.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/97.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Summary Transthoracic, transesophageal, and stress echocardiography may all be useful in the evaluation of patients with acute chest pain presenting to the emergency department. Echocardiography can aid in the diagnosis of cardiac ischemia and myocardial infarction, help assess for other important causes of chest pain, and provide incremental prognostic information on both short- and long-term outcomes. New developments to enhance imaging and endocardial border definition, digital acquisition of images, tele-echocardiography, and the possibility of perfusion-based imaging using echocardiographic contrast promise to increase its utility even further in the future.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/98.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
251
Chapter 12 - Echocardiography in the Coronary Care Unit Management of Acute Myocardial Infarction, Detection of Complications, and Prognostic Implications Elyse Foster MD Zian H. Tseng MD
The earliest experimental models of myocardial infarction demonstrated that regional wall motion abnormalities ensue shortly after cessation of coronary flow.[1] When a coronary artery is ligated, the first abnormality is an impairment in relaxation of the affected wall. The diastolic abnormalities are followed within seconds by the development of systolic contraction abnormalities. These systolic abnormalities can be readily detected by conventional echocardiographic methods and form much of the basis for the echocardiographic evaluation of ischemia. Although segmental abnormalities in diastolic function are not readily measured by conventional echocardiography, the available information regarding global diastolic dysfunction has recently been found to have important prognostic significance.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/100.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Historical Perspective The use of echocardiography in patients with myocardial infarction occurred with the introduction of the first echocardiographic imaging techniques. [2] [3] [4] [5] M-mode echocardiography, with its high frame rate, permitted precise assessment of the reduction in wall thickening, but it was limited by its narrow view of the left ventricle. For example, fractional shortening, measured from the ventricular dimensions at the level of the basal septum and posterior wall, inaccurately represented global left ventricular function in patients with mid and apical wall motion abnormalities. Two-dimensional (2D) sector scanning, developed in the late 1970s, provided the necessary tomographic views for a complete evaluation of regional ventricular function. This bedside imaging method was soon employed widely for the early identification of apical aneurysms and thrombus formation[6] , [7] in patients with anterior myocardial infarction. Two-dimensional quantitative techniques also were developed that could accurately measure left ventricular ejection fraction in the presence of regional wall motion abnormalities. The role of right ventricular infarction in low output syndromes was appreciated,[8] [9] [10] and the high prevalence of post-myocardial infarction pericardial effusions was recognized.
252
The introduction of spectral and color Doppler echocardiography in the mid-1980s further enhanced the role of echocardiography by providing essential hemodynamic information. In addition, timely noninvasive diagnosis of complications of acute myocardial infarction, such as mitral regurgitation and ventricular septal defects, was possible. Newer methods, such as tissue Doppler imaging and mitral flow propagation velocities,[11] have enhanced our capacity to define left ventricular diastolic function
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
Transesophageal echocardiography allows better definition of the anatomic alterations responsible for the complications of acute myocardial infarction (e.g., papillary muscle rupture). Finally, the advances in digital imaging techniques since the 1980s have enabled the dissemination of stress echocardiography, which has assumed a major role in evaluation of patients with ischemic heart disease, as discussed in Chapter 13 and Chapter 14 . The portability of echocardiography and the extent of hemodynamic and anatomic information it provides ensure its place in the coronary care unit (CCU). Although its ability to provide direct information regarding coronary anatomy and myocardial perfusion have been limited to date, there is continued progress in these areas.
MD Consult L.L.C. http://www.mdconsult.com /das/book/view/26070721/1031/101.html/top Bookmark URL:
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Applicable Modes of Echocardiography Transthoracic echocardiography (TTE) provides a rapid bedside assessment of wall motion and global left ventricular function, and it excludes the presence of complications.[12] [13] In the patient presenting with chest pain who has a nondiagnostic electrocardiogram, identification of a segmental wall motion abnormality assists in the determination of definitive therapy. In the patient with an established myocardial infarction, early noninvasive evaluation of ejection fraction indicates therapy with beta blockers, angiotensin converting enzyme inhibitors, or both. When recurrent pain complicates reperfusion therapy, electrocardiographic changes may be nonspecific. In this situation, echocardiography helps differentiate between recurrent ischemia and pericarditis. Importantly, the cause of hemodynamic instability in patients with myocardial infarction often can be established without invasive monitoring. In patients with severe hemodynamic compromise, TTE may be limited by mechanical ventilation and an inability to adequately position the patient. In this group, transesophageal echocardiography (TEE) has proven to be efficacious, especially in ruling out complications related to cardiac rupture.[14] [15] [16] [17] [18] [19] [20] [21] [22] Although large numbers of patients with acute myocardial infarction have not been studied, with careful sedation and close monitoring, TEE can be performed safely.[23] [24] [25] Stress echocardiography has assumed an increasingly important role in assessing the postinfarction patient for evidence of myocardial viability and for assessing the risk for recurrent ischemia. Dobutamine echocardiography, using low doses that do not significantly alter hemodynamics, has been shown to improve function in viable myocardial segments. Higher doses of dobutamine as well as exercise echocardiography can be used to detect residual ischemia, but they should be used with caution early after myocardial infarction.[26] Although one study showed no increase in cardiac enzymes after dobutamine stress, [27]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
there are isolated case reports of free wall rupture in association with highdose dobutamine stress testing within the first week following myocardial infarction.[28] [29] Contrast echocardiography remains investigational for the evaluation of myocardial perfusion. Only one intravenous left-sided contrast agent is commercially available in the United States. Although this agent crosses the pulmonary circulation and opacifies the left ventricular cavity, in the approved dose ranges it does not routinely offer adequate assessment of myocardial perfusion. In a study using an investigational agent, a comparison between single photon emission computed tomography (SPECT) and myocardial contrast echocardiography (MCE) revealed limited sensitivity and high specificity for MCE detection of moderate or severe perfusion defects. MCE also underestimated the extent of SPECT defects. [30] The accuracy of MCE was enhanced by the combination of MCE and wall motion assessment.[30] [31] Rapid technologic developments in this field are under way. Saline contrast may be indicated for enhancement of tricuspid regurgitant jets in order to estimate pulmonary artery pressures and to exclude a patent foramen ovale in patients with cerebral embolization or hypoxemia in the setting of right ventricular infarction.[32] [33]
Although three-dimensional (3D) echocardiography has proved to be an important research tool, it has not yet been widely adopted in the clinical setting. Studies in canine models suggest that accurate quantitation of infarct size with and without the use of myocardial contrast may be possible in the future.[34] [35]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/102.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Advantages and Limitations of Echocardiography in the Coronary Care Unit The major advantages to echocardiography in the CCU include its portability, noninvasive nature, and the wealth of anatomic and hemodynamic information provided. TEE, a semi-invasive technique, has an extremely low complication rate even among the most seriously ill.[36] [37] The limitations of echocardiographic evaluation include the limited transthoracic windows often encountered in the acutely ill coronary care patient, frustrating identification of important complications. Newer technologies such as tissue harmonics have enhanced endocardial border definition even in the most difficult patients. Another limitation is the largely qualitative analysis of regional wall motion abnormalities; quantitative techniques are cumbersome, require manual tracing, and, for the most part, have not been widely employed in the clinical setting.[38] [39] Nevertheless, surface echocardiography remains a mainstay of noninvasive diagnosis in the CCU.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/103.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 8
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Pathophysiology and Echocardiographic Correlations Timing and Evolution of Infarction The effects of acute coronary ligation in animal models of experimental myocardial infarction have been studied by echocardiography, leading to several observations: 253
1. Acute coronary ligation results in diminished systolic wall thickening and outward motion of the affected myocardial segment (dyskinesis) with close correlation between echocardiography and sonomicrometry. [40] [41] [42] [43]
2. The degree of dyskinesis produced was directly related to the severity of the perfusion deficit.[40] 3. Interventions during ischemia that increase afterload worsen wall motion, whereas afterload-reducing and inotropic agents improve wall motion.[40] [44] 4. The extent of wall motion abnormalities correlates with infarct size to a variable degree. In one study the wall motion abnormalities present at 2 hours following coronary ligation tended to overestimate infarct size because function had improved over the subsequent 48 hours. Although in this dog model echocardiographic infarct size even as predicted by late (48 hours) wall motion abnormalities correlated poorly with pathologic infarct size,[45] subsequent studies demonstrated that the extent of regional contraction abnormalities on 2D echocardiography with early (20 minutes) or late (2 days) echocardiography after permanent coronary occlusion correlated well with infarct size.[46] Despite these seemingly disparate results, these early studies provided a
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 8
basis for clinical studies using echocardiography to measure the beneficial effects of pharmacologic interventions on infarct size.[47] [48] [49] [50] [51] Reperfusion Therapy, Myocardial Stunning, and Infarct Size Experimental studies have demonstrated that approximately 30 minutes following an acute coronary occlusion, a wavefront of myocardial necrosis begins to proceed from endocardium to epicardium, resulting in a transmural myocardial infarction over a period of 4 to 6 hours.[52] This observation, coupled with the work of DeWood et al,[53] who demonstrated that an acute coronary thrombosis was responsible for most acute myocardial infarctions, led to what is probably the major therapeutic advance in cardiology: the use of thrombolytic therapy or primary angioplasty for acute myocardial infarction. The theoretical basis for the use of early reperfusion is grounded in the work of early investigators in this field who showed that timely restoration of coronary flow (i.e., coronary reperfusion) salvages myocardium. However, improvement in flow had variable immediate effects on wall motion abnormalities, with most animals showing improvement but others showing no improvement or even worsening.[40] After reperfusion there is no significant correlation between infarct size and extent of regional dyskinesis or area of systolic wall thinning by 2D echocardiography after reperfusion performed up to 10 days after reperfusion.[46] [54] Thus, echocardiographic wall motion abnormalities as a predictor of infarct extent appeared to be more accurate following permanent occlusion than after occlusion with reperfusion. There are several plausible explanations for the lack of correlation between infarct size and regional wall motion abnormalities in reperfused myocardium. Most often echocardiographic assessment results in an overestimation of infarct size. After restoration of flow, there may be persistent postischemic dysfunction in viable myocardial segments, known as myocardial stunning. The pathophysiologic basis for this phenomenon is covered in several excellent reviews.[55] [56] [57] Wall motion abnormalities 2 weeks after reperfusion correlate better with infarct size, [54] which suggests that return of function of stunned myocardium may be significantly delayed. The rate at which reperfusion occurs also affects function, and it may be relevant in terms of the type of therapy chosen in the acute postinfarction period. In a canine model of infarction, sudden complete reperfusion resulted in increased wall thickness and slow return of function over a 7-day period, which is consistent with cell swelling and reperfusion injury (albeit reversible). In contrast, staged partial reperfusion (followed
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 8
by complete reperfusion) did not lead to an immediate increase in wall thickness, with functional recovery being seen as early as 30 minutes.[58] Thus, echocardiography early after a reperfused myocardial infarction (i.e., within 2 weeks) may overestimate the eventual area of necrosis because of stunning, reperfusion injury, or both. Infarct size also may be overestimated if the abnormal motion of infarcted myocardium impairs endocardial motion of adjacent normal myocardium owing to a "tethering" effect. [59] Alternately, the area of necrosis may be underestimated in the presence of a nontransmural infarction that subtends less than 25% of the wall thickness, with the salvaged normal subepicardial region resulting in overall normal segmental function.[60] In patients with old infarctions (>6 months), echocardiographic infarct size tends to underestimate the volume of necrosis when measured at autopsy.[61] In some cases, the ventricular remodeling process may be responsible for the change in the tendency from early (<2 weeks) overestimation to late (>6 months) underestimation of infarct size.[62] To identify postischemic ventricular dysfunction or "stunned myocardium," investigators have examined the effect of inotropic stimulation on the function of reperfused, noninfarcted myocardium and compared it with the effect on infarcted tissue. Serial 2D echocardiography during dopamine infusion demonstrates an increase in the contractility of the reperfused myocardium, with improvements in systolic wall thickening and fractional area change. This improvement in regional function is associated with an improvement in regional myocardial blood flow.[63] This study and others provided the experimental basis for the clinical use of dobutamine in detecting myocardial viability.[64] [65] [66] [67] [68] [69] Another echocardiographic method under investigation for determining myocardial viability is ultrasonic tissue characterization.[70] [71] [72] Nonischemic myocardium shows cyclic variation in the integrated backscatter, whereas in ischemic myocardium this variation is diminished or lost. MCE using sonicated iodinated contrast media identifies segments with persistent flow deficits despite reperfusion of the epicardial vessel. The areas of no reflow are believed to be due to microvascular damage and correspond to nonviable segments as identified by positron emission tomography and thallium scintigraphy.[73] MCE also can measure the extent of microvascular occlusion,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 8
254
which occurs after prolonged ischemia and prevents adequate reperfusion. [74]
Infarct Localization Infarcts are localized both with respect to the transmural extent of the infarction (i.e., subendocardial versus transmural) and to the anatomic location as related to the coronary distribution of the infarct related artery. Small nontransmural (i.e., subendocardial) myocardial infarctions may not be detected as an abnormality in contractile function. The transmural extent of infarction and regional systolic function is inversely related to fractional radial shortening in both acute (6 hours after occlusion) and subacute (72 hours after occlusion) infarctions.[60] [75] [76] Fractional shortening continues to deteriorate as the percent of total wall (transmurally) involved increases from 75% to 100%, contradicting the work of others who suggested the subepicardial third of the myocardium contributed little to systolic wall thickening.[77] The circumferential extent of the infarction and, to a lesser extent, its longitudinal extent (i.e., base to apex) correlate with the distribution of the affected coronary artery.[78] [79] The anterior, anterolateral, anteroseptal, and apical (anterior and septal) segments correspond roughly to the left anterior descending artery (LAD) distribution. The lateral wall and lateral apex are in the distribution of the left circumflex. The inferolateral wall is supplied by the posterior descending artery. In 80% of the population, the posterior descending artery arises from the right coronary artery (RCA) and supplies the inferolateral wall as well as the inferior free wall and inferior septum (right dominant). In the other 20% of patients, the posterior descending artery arises from the circumflex artery (left dominant system). The right ventricle is supplied by the RCA via its acute marginal branches. In general, infarctions in the LAD distribution tend to be more apically situated, whereas those in the RCA and the circumflex distribution are more basal in their location. Moreover, the extent of apical involvement and its distribution depends, to a degree, on the relative supply from the left anterior and posterior descending arteries. Of course, the presence of collaterals and previous bypass surgery alters the distribution of ischemia and infarction relative to the involved arterial supply. The most commonly accepted method for analyzing wall motion uses the 16-segment model recommended by the American Society of Echocardiography[38] (Fig. 12-
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 8
1) , with the approximate and most common native coronary arterial distribution in relation to these segments depicted in Figure 12-2 . Experimental Models of Mitral Regurgitation Mitral regurgitation is common in the setting of acute myocardial infarction. Only recently have experimental studies elucidated the mechanism. These studies have demonstrated incomplete coaptation of the mitral valve leaflets owing to alteration of systolic left ventricular geometry Figure 12-1 The 16-segment model for segmental wall motion analysis recommended by the American Society of Echocardiography.[29] A, anterior; AL, anterolateral; AS, anteroseptal; I, inferior; IL, inferolateral; IS, inferoseptal; L, lateral; PSAX, parasternal short axis; S, septal; SAX, short axis.
during ischemia.[80] [81] Infarction of a papillary muscle and the underlying ventricular myocardium results in incomplete leaflet coaptation owing to an increase in the distance from the point of mitral leaflet coaptation to the mitral annulus.[81] [82] Although the extent of the underlying wall motion abnormality may be small and left ventricular function may be globally preserved, papillary muscle ischemia alone is insufficient to cause mitral regurgitation. These studies are supported by the clinical observation that mitral regurgitation occurs in patients with ischemia or infarction of the inferolateral or posteromedial papillary muscle and a small area of underlying myocardium with otherwise well-preserved left ventricular function.[15] Incomplete leaflet coaptation also may occur as a result of severe global left ventricular dysfunction rather than localized papillary muscle dysfunction. [80] The proposed mechanisms contributing to malcoaptation of the leaflets in the setting of global ventricular dysfunction include a prolonged rate of rise of left ventricular pressure (i.e., Figure 12-2 Arterial distribution of blood flow superimposed on a parasternal short-axis view. LAD, left anterior descending; LCx, left circumflex; RCA, right coronary artery.
255
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 8
decreased dP/dt), with less force exerted on the mitral leaflets; poor systolic approximation of the left ventricular walls; mitral annular dilation; and malalignment of the papillary muscles owing to increased left ventricular end-diastolic volume. More recent data from a canine model using 3D echo-cardiography suggest that functional mitral regurgitation associated with left ventricular systolic dysfunction occurs only in the presence of left ventricular dilation.[83] Hemodynamically significant mitral regurgitation relates strongly to the 3D geometry of the mitral valve attachments at the papillary muscle and annular in the presence of left ventricular dilation (i.e., postpericardiectomy). Likewise, in vitro modeling studies demonstrated an integrated mechanism of regurgitation in which an altered balance between abnormal leaflet tethering and decreased coapting forces results in mitral incompetence.[84] Thus, hemodynamically significant mitral regurgitation is seen both in patients with small inferior myocardial infarctions and posteromedial papillary muscle involvement and in patients with large anterior infarctions, left ventricular dilation, and globally reduced systolic function. Infarct Healing and Remodeling Echocardiographic studies have contributed significantly to the understanding of infarct healing and the ventricular remodeling that takes place in the hours and days following an acute myocardial infarction. The importance of these phenomena are recognized in relation to the beneficial effects of delayed reperfusion and afterload reduction with angiotensin converting enzyme inhibitors that reduce infarct expansion and ventricular dilation. The concept of infarct expansion originated with the observation that the infarcted segment of myocardium thins and stretches with an increase in the circumferential extent of the necrotic zone (Fig. 12-3) (Figure Not Available) . The clinical observation that infarct expansion is associated with higher mortality, both early (in-hospital) and late after myocardial infarction, [85] [86] , [72] led to the postulate that the change in the topography of the infarcted zone increases the hemodynamic burden on the remaining normal walls, Figure 12-3 (Figure Not Available) Concept of infarct expansion. In the initial phase of the infarction (left), there is regional dilation and thinning limited to the infarcted region. Over time, in addition to further expansion of the area of infarct, there may be
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 8
compensatory dilation of the remaining ventricle (right). (Redrawn from Eaton LW, Weiss JL, Bulkley BH, et al: N Engl J Med 1979;300:57–62. Copyright 1979 Massachusetts Medical Society. All rights reserved.)
resulting in ventricular dilation and hypertrophy.[85] [87] [88] Both clinical and experimental data suggest the following: 1. Expansion of the endocardial segment occurs as early as 10 minutes after occlusion.[89] 2. Infarct thinning and expansion are progressive over a period of 7 days. [88]
3. A critical mass of infarction (approximately 20% of total left ventricular mass) was required for expansion.[90] 4. Infarct expansion in the dog is more likely after LAD than after left circumflex occlusion.[89] 5. Infarct expansion led to aneurysm formation.[88] 6. The segment lengths of normal myocardium increase in the presence of infarct expansion, leading to ventricular dilation.[91] 7. Microvascular obstruction in infarcted tissue plays a role in remodeling by reducing local myocardial function, which contributes to the dysfunction of adjacent noninfarcted myocardium.[92] The clinical significance of infarct expansion is further emphasized by the demonstration of the beneficial effects of a patent infarct-related artery. [87] Histologic studies in a rat model of infarction demonstrated that reperfusion too late to salvage myocardium (no reduction in infarct size or transmurality) inhibits infarct expansion[93] and was associated with increased scar thickness.[94] Echocardiographic studies in dogs showed that delayed reperfusion of an infarct (as late as 5 to 6 hours after occlusion) acutely decreases the degree of infarct thinning and ventricular dilation.[95] [96] Although delayed reperfusion may convert a bland infarct into a hemorrhagic infarct and may increase the risk of myocardial rupture slightly, many clinical studies support the concept that an open artery provides substantial benefit, possibly through decreased left ventricular dilation and aneurysm formation and, as a corollary, a decreased incidence of arrhythmias and a lower mortality.[87] [97] The time course of left ventricular remodeling following successful reperfusion in acute myocardial infarction is suggested by a 2D echocardiographic study that showed progressive infarct thinning for up to 1 month and left ventricular dilation for up to 14 days. The degree of remodeling as reflected in left ventricular volume was greatest in the patients with the largest infarcts (peak creatine kinase > 8000 U/L). Despite the progressive remodeling,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 8
wall motion score improved rapidly by 14 days, and it continued to improve gradually to 1 year. [98] Vasodilator therapy, theoretically through a reduction of left ventricular wall stress, influences post–myocardial infarction remodeling and improves prognosis. The salutary effects of treatment with angiotensin converting enzyme inhibitors, first shown in a rat model by Pfeffer et al,[99] [100] include attenuation of left ventricular dilation, improved left ventricular performance with a downward shift of the pressure-volume curve and higher ejection fraction, and improved long-term survival. These findings were subsequently confirmed in post–myocardial infarction patients with left ventricular dysfunction in the Survival and Ventricular Enlargement (SAVE) trial. Two canine studies using echocardiographic measurements have shown that nitrates and enalapril had similar beneficial effects on the remodeling process.[101] [102] The Carvedilol Heart Attack Pilot Study (CHAPS) demonstrated 256
attenuation of left ventricular remodeling with postinfarction administration of carvedilol. Echocardiography at baseline and after 3 months of treatment showed reduced left ventricular volumes and sphericity (long-axis–to– short-axis ratio).[103]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/104.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 10
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Echocardiography in the Diagnosis and Early Risk Stratification of Acute Myocardial Infarction Transferring the experience from the animal laboratory into the CCU, clinical investigators have confirmed the usefulness of echocardiography in diagnosis, localization, prognostic staging, and detecting of complications of myocardial infarction. Diagnostic Role of Echocardiography For an imaging modality to be useful in the diagnosis of myocardial infarction, it must be feasible in the majority of patients. Images of the left ventricle adequate for segmental analysis of wall motion can be obtained in greater than 90% of patients by skilled sonographers.[104] [105] [106] Tissue harmonic imaging and left-sided contrast agents have increased the percentage of patients in whom technically adequate images can be obtained.[107] [108] [109] In one study of segmental and global function in 70 critically ill patients, the number of uninterpretable segments fell from 5.4 with fundamental (standard) imaging to 4.4 with harmonic imaging and finally to 1.1 with a left-sided contrast agent. In addition, the usefulness of the modality is directly related to its sensitivity and specificity and to the prevalence of the disease in the population studied. The accuracy of an echocardiographic diagnosis of a myocardial infarction is dependent on echocardiography's ability to detect wall motion abnormalities in the involved segment. As shown in the animal laboratory, the severity of the wall motion abnormality depends on the transmural extent of the infarction and the circumferential limits depend on the arterial distribution and collateral blood supply. In considering the specificity of wall motion abnormalities for diagnosis of acute myocardial infarction, other causes of segmental dysfunction must be recognized. A false-positive diagnosis can often be avoided if wall
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 10
thickening is examined in addition to endocardial motion. The inward motion of the endocardial surface may be delayed or paradoxical owing to abnormal conduction in the presence of Wolff-Parkinson-White syndrome, [110] a left bundle branch block,[111] or right ventricular pacing. [112] Paradoxical septal motion also is present in right ventricular volume overload and following open heart surgery.[113] [114] In these conditions, the systolic thickening of the septum or other involved segment (e.g., posterolateral wall in Wolff-Parkinson-White syndrome, type A) should be preserved.[115] Nonischemic causes of segmental dysfunction that result in reduced systolic thickening and endocardial motion include focal myocarditis[116] and idiopathic cardiomyopathy. Several studies that have examined the specificity of echocardiographic wall motion abnormalities for diagnosis of acute myocardial infarction are worth noting. Among 65 patients presenting to the emergency room with chest pain, there were 5 false-positive echocardiograms, demonstrating regional asynergy in patients without infarction for a specificity of 85%.[117] In a more recent study by Peels et al[118] of 43 patients with chest pain and normal or nondiagnostic electrocardiogram, the specificity of echocardiographic wall motion abnormalities was 78% for ischemia and only 53% for infarction. The apparent discrepancy between the two studies is probably due to differences in prevalence of disease in the population studied. Sabia et al[105] used echocardiography to study 202 patients presenting to the emergency room with acute shortness of breath or chest pain. Of the 140 patients who were ruled out for myocardial infarction, 60 had regional wall motion abnormalities detected by echocardiography. Of those patients, 52% (31 of 60) had had a prior infarction and 53% (32 of 60) were found to have evidence of coronary artery disease on subsequent testing. Although the development of electrocardiographic Q waves is usually associated with a transmural infarction, the absence of Q waves does not always signify a nontransmural or subendocardial infarction.[119] Non–Qwave infarctions are usually smaller, are associated with smaller enzyme leaks,[120] and more often are in the distribution of the left circumflex artery. [121] Two-dimensional echocardiographic evidence of a wall motion abnormality is present in 90% to 100% of patients with Q-wave infarctions [117] [122] [123] [124] compared with 75% to 85% in patients with non–Q-wave [104] [114] [117] [123] [124] [125] infarctions. , The most widely used scoring system for grading the severity of a wall
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 10
motion abnormality is that recommended by the American Society of Echocardiography, in which normal = 1, hypokinesis = 2, akinesis = 3, dyskinesis = 4, and aneurysm = 5[38] (Table 12-1) . Unlike other published scales,[106] hyperkinesis is not distinguished from normal contraction. Weiss et al[124] demonstrated that the finding of akinesis or dyskinesis is most common in the setting of transmural infarction, with milder degrees of wall motion abnormalities (i.e., hypokinesis) most likely representing nontransmural infarction or ischemia. Localization of Infarction Clinical studies have documented the accuracy of echocardiography in identifying the site of coronary occlusion. Echocardiographic localization has significant advantages TABLE 12-1 -- Scoring System for Grading Wall Motion[38] Score 1 2 3 4 5
Wall Motion Normal Hypokinesis Akinesis Dyskinesis Aneurysmal
Endocardial Motion * Normal Reduced Absent Outward Diastolic deformity
Wall Thickening * Normal (>30%) Reduced (<30%) Absent Thinning Absent or thinning
*In systole.
257
over electrocardiographic localization, particularly for apical and lateral wall myocardial infarctions. Pierard et al[126] correlated echocardiographic infarct location with the site of coronary obstruction by coronary angiography in 45 patients and by necropsy in 4 patients. They assigned specific segments to the major coronary branches and found the following sensitivities: basal anterior = first diagonal (LAD, 71%) basal anteroseptal = first septal perforator (LAD, 83 middle anterior = second diagonal (LAD, 100%)
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 10
middle anteroseptal = second septal (LAD, 89%) basal posteroseptal = dominant RCA (89%) right ventricular anterolateral segment = right ventr ular marginal branch (83%)
Ogawa et al[127] analyzed the location of echocardiographic wall motion abnormalities, electrocardiographic Q wave, and angiographic site of coronary artery occlusion in 26 patients with single-vessel disease. Inferior Q waves (II, III, and aVF) were associated with mid-inferior wall motion abnormalities. Furthermore, extension to the inferior septum correlated with RCA disease, whereas extension to the inferolateral wall correlated with circumflex coronary disease. A tall R wave in V1 was associated with
posterolateral wall motion abnormalities and a coronary lesion of the proximal circumflex artery. Electrocardiographic evidence of lateral infarction (Q in lead I or aVL) correlated with wall motion abnormalities of the inferolateral and anterolateral walls and disease in the circumflex system involving a large obtuse marginal branch. Circumflex disease also was associated with the presence of a Q wave in V6 and dyssynergy of the lateral and inferior apical walls.[127]
These studies did not compare echocardiographic to electrocardiographic localization of infarction. However, a study by Otto et al[106] suggested that imaging may be more precise, with an 81% concordance between echocardiography and angiography compared with 76% for electrocardiography.[106] Thus, the use of echocardiography to identify the region of segmental dyssynergy in the patient presenting with a myocardial infarction is clinically accurate in determining the site of coronary occlusion (Table 12-2) . One caveat is that the presence of pre-existing wall motion abnormalities and surgical grafts or collateral circulation altering the distribution of flow must be taken into account. Right Ventricular Infarction Right ventricular infarction (Table 12-3) occurs in up to one third of patients with inferior wall infarction and is seen rarely in patients with anterior infarction. The right ventricle is predominantly supplied by acute marginal branches of the RCA that arise in the middle third of its anatomic course. Occlusion of the RCA proximal to the origin of these branches results in ischemia and usually infarction of the right ventricle. Much less frequently, the right ventricle receives blood supply from a dominant left circumflex artery. In addition, the anterior apex of the right ventricle may
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 10
be supplied by the LAD "wrapping" around the apex of the heart. TABLE 12-2 -- Coronary Distribution Associated with Echocardiographic Segments Echocardiographic Segment Coronary Artery Supply * Base Anterior septum Proximal LAD Anterior Proximal LAD Anterolateral Proximal LAD (LCx) Inferolateral LCx Inferior RCA Inferior septum RCA Mid Anterior septum Mid LAD Anterior Mid LAD Anterolateral Mid LAD (LCx) Inferolateral LCx Inferior RCA Inferior septum RCA Apex Anterior Distal LAD Lateral Distal LAD Septum Distal LAD Inferior PDA (LAD) LAD, left anterior descending artery; LCx, left circumflex artery; PDA, posterior descending artery; RCA, right coronary artery. *Coronary distribution is variable in the presence of revascularization.
The hemodynamic consequences of right ventricular infarction were first recognized in the mid-1970s with several descriptions of the associated
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 10
clinical syndrome appearing simultaneously in the literature.[128] [129] Using gated scintigraphy, detectable right ventricular dyssynergy was reported by other investigators shortly thereafter.[130] [131] In one of these reports, Sharpe et al[112] also described the M-mode echocardiographic finding of right ventricular infarction. In 6 patients, they found evidence of right ventricular enlargement and paradoxical septal motion correlating with the scintigraphic and hemodynamic findings. Isner and Roberts[132] reported the incidence of right ventricular infarction in 236 necropsy specimens of acute and chronic infarctions. In their series, none of the 97 patients with pathologic evidence of an isolated anterior wall myocardial infarction had right ventricular involvement. In contrast, the incidence of right ventricular involvement in patients with infarction involving the posterior wall was 24% (33 of 139). Specifically, all of the right ventricular infarcts, which were confined to the posterior portion of the right ventricular free wall, TABLE 12-3 -- Echocardiographic Signs of Right Ventricular Infarction PRIMARY Right ventricular dilation Segmental wall motion abnormality of the right ventricular free wall Decreased descent of the right ventricular base SECONDARY Paradoxical septal motion Tricuspid regurgitation Tricuspid papillary muscle rupture Pulmonary regurgitant jet pressure half-time ≤150 msec Dilated inferior vena cava Right-to-left interatrial septal bowing Right-to-left shunting across patent foramen ovale
258
occurred in the 65 specimens with transmural infarction involving the posterior septum (33 of 65, or 50%). A subsequent pathologic study described that infarction of the right ventricular anterior free wall occasionally can be contiguous with an extensive anteroseptal infarction.[133] The diagnosis of right ventricular infarction should be suspected in a
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 10
patient with evidence of jugular venous distention and clear lung fields in the setting of an inferior myocardial infarction. Although the electrocardiographic sign of ST segment elevation in V4R is both sensitive
and specific for the diagnosis,[134] it does not provide information as to the extent of involvement. The 2D echocardiographic signs of right ventricular infarction include right ventricular dilation, decreased right ventricular function, segmental wall motion abnormalities, and paradoxical septal motion (Fig. 12-4) .[135] Quantitative measurement of right ventricular ejection fraction by echocardiography is difficult because of the lack of an adequate geometric model for calculation of volumes; instead, fractional area change and descent of the right ventricular base are commonly used measures of right ventricular function. Right ventricular failure with high right atrial pressures results in bowing of the interatrial septum into the left atrium and dilation of the inferior vena cava with lack of inspiratory collapse.[136] Echocardiographic indicators of right ventricular function correlate with clinical status and prognosis. Goldberger et al[136] compared the echocardiographic characteristics in patients with hemodynamically significant infarction (jugular venous pressure [JVP] > 13 mm Hg; n = 9) with those without (JVP < 13; n = 15). There was no difference in the frequency of detectable wall motion abnormalities between the two groups (77% versus 66%). However, the group with higher estimated JVP had less descent of the base (.7 cm versus 1.3 cm); less inspiratory collapse of the inferior vena cava (22% versus 45%) and a greater right-to-left ventricular size ratio (1.1 versus 0.6). The pressure half-time of the pulmonary regurgitant jet reflects the compliance of the right ventricular Figure 12-4 Four-chamber view of an echocardiogram from a patient after an inferior infarction with right ventricular involvement. There is enlargement of the right ventricle (RV) and right atrium (RA). The left ventricle (LV) appears small and the interatrial septum is deviated from right to left, suggesting elevated right atrial and right ventricular enddiastolic pressures.
chamber. In a recent study, a short pressure half-time of the pulmonary regurgitant jet (<150 msec) in patients with right ventricular infarction was the only predictor of in-hospital events.[137] Thrombolytic therapy has been proved efficacious in right ventricular infarction, and echocardiographic features correlate with effective revascularization. In a recent study of 108 consecutive patients with a right ventricular infarction, there was a 78%
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 10
correlation between Thrombolysis in Myocardial Infarction (TIMI) grade III perfusion in and normalization or improvement of right ventricular function by echocardiography.[138] Interatrial septal motion and interventricular septal motion normalized in all reperfused patients. The major complication rate and mortality were higher in patients with echocardiographic findings of right ventricular dysfunction persisting after thrombolytic therapy.[138] Two other complications associated with right ventricular infarction deserve mention. First, papillary muscle dysfunction associated with ischemia and right ventricular dilation may result in functional tricuspid regurgitation. Rarely, papillary muscle rupture may involve the tricuspid valve. Second, severe hypoxemia owing to right-to-left shunting across a patent foramen ovale has been reported with large right ventricular infarctions in association with elevated right atrial pressures. [139] Echocardiography for Prediction of Early Mortality Using echocardiography in the setting of acute myocardial infarction, clinical investigators have identified several important prognostic indices: (1) the extent of the wall motion abnormalities within the infarct zone; (2) the degree of infarct expansion and ventricular dilation; and (3) the presence of wall motion abnormalities outside the infarct zone (i.e., infarct extension). The importance of diastolic function as a prognostic indicator is discussed later. An echocardiographic wall motion score has been the most widely used measure of functional infarct size in clinical practice. The total score is derived by assigning a grade of 1 through 5 (see Table 12-1) to each myocardial segment that is adequately visualized. For a segment to be scored, the majority of the endocardium within that segment must be apparent, and wall thickening and endocardial motion should be examined. The scores for each segment are added and then divided by the number of segments graded for a total wall motion score. Several studies have demonstrated that a higher wall motion score index (12 to 24 hours after admission) is associated with a higher rate of in-hospital complications, including malignant arrhythmias, pump failure, and death.[104] [140] A higher wall motion score index also predicts a higher rate of complications, including free wall rupture, ventricular septal defect or papillary muscle rupture, and death from cardiogenic shock.[140] A higher wall motion score, signifying a more extensive infarction, also is predictive of late mortality. [140] [141] In reviewing the literature on this subject, it is important to
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 10
recognize that many different scoring systems have been described, with consequent variability 259
in the absolute number of the wall motion score index associated with a poor prognosis. Infarct expansion is defined as an increase in the endocardial surface area of the infarcted zone owing to thinning and stretching secondary to necrosis and scar tissue formation. A landmark study in 1979 used serial 2D echocardiography to study 28 patients in the first 2 weeks after myocardial infarction. In eight patients, all with anterior infarctions, there was a progressive increase in the endocardial length of the infarcted segment and progressive ventricular dilation. In the group without infarct expansion (9 inferior myocardial infarction patients, 11 anterior myocardial infarction patients), there was little or no dilation. Although the number of patients in each group was too small from which to draw firm conclusions, the group with infarct expansion had a higher mortality rate (50%) compared with the group without expansion (0%). Other clinical studies have suggested that this mechanism contributes to congestive heart failure and poor functional status after infarction.[142] Later studies in the era of reperfusion confirm that infarct expansion is more common in anterior infarctions, but they suggest that most of the dilation is present by 3 hours.[143] Wall motion abnormalities remote from the infarction site may be present early in the course of the infarction or may develop in the presence of postinfarction angina, suggesting de novo ischemia. The echocardiographic finding of remote asynergy at or soon after clinical presentation is strong evidence of multivessel disease. Abnormal wall motion in a second (or even third) coronary distribution is possibly due to (1) previous infarction, (2) increased myocardial oxygen demands placed on the noninfarcted segment as a result of increased wall stress outstripping its oxygen supply, (3) a cessation in its collateral blood supply that originated from the newly occluded vessel, or (4) simultaneous infarctions in multiple coronary beds, the least likely cause.[144] Infarct extension results from the development of ischemia and infarction in a region remote from the original site after the initial event. Postinfarction angina with electrocardiographic changes distant from the acute infarct (i.e., "ischemia at a distance") is associated with a worse
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 10
prognosis than ischemia within the infarct zone.[145] Although early observations were based on electrocardiographic evidence alone, more recent echocardiographic investigations show similar results.[125] [145] [146] Isaacsohn et al[146] performed echocardiography during 19 episodes of postinfarction ischemia. Echocardiographic extension was detected in seven of nine episodes with clinical evidence of extension (recurrent chest pain, new increase in creatinine kinase level, or new electrocardiographic changes). The in-hospital mortality rate was significantly greater in those with echocardiographic evidence of infarct extension (50% versus 12%) and was poorest in those with a high wall motion score.
MD Consult L.L.C. http://www.mdconsult.com /das/book/view/26070721/1031/105.html/top Bookmark URL:
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 20
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Detecting Complications of Acute Myocardial Infarction The prognosis of myocardial infarction is directly related to the extent of necrosis (Table 12-4) . A large TABLE 12-4 -- Echocardiography in Complications of Myocardial Infarction HEMODYNAMIC STATES Hypovolemia Right ventricular infarction Globally reduced left ventricular contractility MECHANICAL COMPLICATIONS Papillary muscle rupture Ventricular septal rupture Free wall rupture and tamponade OTHER Left ventricular aneurysm Mural thrombus infarction encompassing greater than 40% of the heart is likely to result in severe pump failure. Transmural infarction is more likely to result in complications related to rupture, occurring in up to 3% of patients. Thus, in the hemodynamically unstable patient, it is critical to exclude rupture, a situation that is potentially amenable to surgery, before concluding that cardiogenic shock is on the basis of pump failure. In most cases, TTE (supplemented when necessary by TEE) is sufficient to exclude papillary muscle, free wall, and ventricular septal ruptures. Hemodynamic Classification of Myocardial Infarction Using Doppler Echocardiography
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 20
A carefully performed Doppler echocardiographic study can provide sufficient information to determine a patient's hemodynamic category after infarction. A hemodynamic classification on the basis of these well-studied parameters is given in Table 12-5 . A simple method of estimating stroke volume is to measure the stroke distance, that is, the velocity time integral (VTI) of aortic flow by pulsed wave or continuous wave Doppler. Although continuous wave Doppler measurements are more reproducible, they can be used only in patients with normal semilunar valves; even a mild degree of stenosis increases the VTI. At a heart rate of 70 to 80 beats per minute, the normal stroke distance is 13 to 15 cm for the pulmonary artery and 18 to 20 cm for the aorta.[147] [148] Stroke distance varies inversely with heart rate, but it holds constant over a wide range of body surface areas.[149] This method eliminates the error in cardiac output measurements introduced by estimating the cross-sectional area of the orifice. Moreover, stroke distance measurements are simple to measure online. Recently, automated cardiac output measurements, based on the digital velocities from color flow mapping, have become available on some systems.[150] A more detailed discussion of Doppler measurements of cardiac output is found in Chapter 26 . Mitral inflow, measured at the tips of the leaflets in the four-chamber view, is informative with regard to diastolic function and left ventricular filling pressures.[151] Derived parameters of the time velocity curve include the ratio of peak early filling velocity to atrial filling velocity (E/A 260
TABLE 12-5 -- Hemodynamic Classification of Myocardial Infarction * by Echocardiography Hemodynamic Category LVEF Normal Nl Hyperdynamic Nl to incr Hypovolemia
Pulmonary LVOT Mitral Venous RVEF VTI E/A Flow Nl 20 A wave S > D † cm dom † Nl >20 A wave S > D † cm dom †
Variable Nl
<20
A wave S > D †
PASP (TR velocity) IV Nl N Nl to slight incr Nl to
N
Sm
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
LV Failure Mild
Pagina 3 di 20
Mild decr Mod decr Severe decr Variable
Nl to decr Nl to decr Nl to decr Decr
cm
dom †
Mild decr Mod decr Sev decr Decr
E wave dom E wave dom E wave dom A wave dom †
decr
S>D
sp co
Mild incr Mod incr Mod incr Decr
N pl Severe S< D Incr N incr decr pl decr, decreased; D, diastolic; dom, dominant; E/A, ratio of early to late (a ventricular diastolic inflow velocity; incr, increased; IVC, inferior vena cava left ventricular ejection fraction; LVOT, left ventricular outflow tract; Mod, MR, mitral regurgitation; Nl, normal; PASP, pulmonary artery systolic pres right ventricular; RVEF, right ventricular ejection fraction; S, systolic; SFR flow reversal; TR, tricuspid regurgitation; VSD, ventricular septal defect; V velocity time integral; w/o, without. *As described by Pasternak, Braunwald, and Sobol.[162] †In the infarction age group. ‡Dependent on extent of LV infarction.
ratio), the deceleration time of early filling curve and the isovolemic relaxation time. Two distinct patterns of inflow reflect the two categories of diastolic dysfunction: impaired left ventricular relaxation and decreased left ventricular compliance. Impaired relaxation is characterized by a decreased E/A ratio and prolonged deceleration and isovolumic relaxation times; this pattern is encountered in chronic ischemic heart disease and hypertension and as a result of normal aging. The restrictive flow pattern noted under
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 20
conditions of diminished left ventricular compliance demonstrates an increased E/A ratio and shortened isovolumic relaxation and deceleration times. This inflow pattern occurs in restrictive cardiomyopathies and in association with elevated filling pressures. An intermediate stage of diastolic function is present with "pseudonormalization" of the mitral filling pattern, usually associated with a moderate elevation of filling pressures. In a recent study of postinfarction patients with left ventricular ejection fraction less than 35%, a mitral deceleration time of less than 120 msec was highly predictive of a pulmonary capillary wedge pressure of greater than 20 mm Hg[152] (Fig. 12-5) . In a second study of patients with systolic dysfunction after infarction (ejection fraction >40%), there was an increased rate of adverse events in two years of follow-up in patients with higher mitral E/A ratios and shorter deceleration times.[153] This finding has been confirmed in subsequent studies[11] [154] [155] (Table 12-6) . Several new parameters of diastolic function have been studied in postinfarction patients. The deceleration time of the diastolic component of pulmonary venous flow has a better correlation with wedge pressure in post patients with myocardial infarction than does the mitral deceleration time. The sensitivity and specificity of a pulmonary venous deceleration time less than 160 msec in predicting greater than or equal to 18 mm Hg in pulmonary capillary Figure 12-5 Mitral inflow signal from a patient with a large anterior myocardial infarction. There is an increased E wave velocity and a shortened deceleration time. The deceleration time was measured between the two arrows as 80 msec. This measurement is evidence of elevated filling pressures and is a poor prognostic sign (see text).
261
TABLE 12-6 -- The Role of Diastolic Functional Parameters in Prognosis After Myocardial Infarction Reference n Comment Pozzoli et 107 Patients with cardiac events had significantly higher E/A ratios and shorter mitral deceleration time al[153] Sakata et 206 Decreased A wave was associated with high in-hospital mortality and congestive heart failure al[154]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 20
Nijland et 95 1-yr survival rate: restrictive filling, 50%; nonrestrictive al[155] filling, 100% Moller et 110 Deceleration time < 140 msec was the most powerful predictor of cardiac death al[11] Total 518 wedge pressure were 97% and 96%, respectively, compared with 86% and 59%, respectively, for a mitral deceleration time of less than 130 msec.[156] The propagation velocity of mitral inflow measured on M-mode color Doppler echocardiography also has prognostic significance.[11] Technically adequate pulmonary venous flow tracings can be obtained in the majority of patients with surface echocardiography. The predominant pulmonary venous flow pattern is triphasic, with the initial systolic (S) forward flow in pulmonary veins occurring during atrial relaxation (xdescent), a second systolic phase coinciding with basal descent of the left ventricle, and forward flow during diastole (D) occurring in the conduit phase of ventricular filling while the mitral valve is open (y-descent). During atrial systole there is a low-velocity retrograde flow signal (A wave). In subjects older than 40 years of age with normal filling pressures, the peak velocities and VTIs are higher during systole than during diastole, and the duration of the pulmonary venous A wave is less than that of the mitral A wave. With high filling pressures, diastolic filling predominates and the A wave duration exceeds that of the mitral A wave.[110] [157] [158] In patients with acute myocardial infarction, a systolic fraction of pulmonary venous flow less than 45% was highly associated with a pulmonary capillary wedge pressure greater than 18 mm Hg.[150] Additionally, systolic flow reversal in the pulmonary veins is an important sign of hemodynamically significant mitral regurgitation.[159] Measurements of pulmonary artery systolic pressure using tricuspid regurgitant jets with or without contrast enhancement have been well validated in the literature,[160] and the size and respiratory dynamics of the inferior vena cava can be used to estimate right atrial pressure. [161] Combining these parameters with measurements (quantitative or qualitative) of left and right ventricular function and color flow Doppler interrogation for valvular abnormalities results in a comprehensive evaluation of the hemodynamic state after infarction as defined by
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 20
Pasternak, Braunwald, and Sobel[162] using invasive data. A recent study found that a combination of automated Doppler cardiac output and pulmonary venous flow measurements was highly accurate in predicting the hemodynamic subset as measured invasively.[150] When the data are incomplete from a transthoracic examination, one should not hesitate to employ TEE given its established safety even in the critically ill patient. Of course, the hemodynamic information available from an echocardiographic examination is available only at a single point in time, and continued invasive monitoring may be necessary in patients with ongoing instability. Recurrent Ischemia After Infarction Although there have been few studies evaluating the usefulness of echocardiography in patients with recurrent ischemia after myocardial infarction, many clinicians rely on echocardiographic evaluation in this setting, given the sensitivity of this technique for detection of wall motion abnormalities. Worsening of wall motion after initial improvement suggests reocclusion of the infarct-related vessel. Wall motion abnormalities in regions remote from the area of infarction suggest multivessel disease.[146] In addition, alternative causes for chest pain after myocardial infarction (e.g., pericarditis) may be evident on echocardiographic examination. Postinfarction Pericarditis and Pericardial Effusion Postinfarction pericarditis most often occurs after a Q-wave infarction between 3 and 10 days following the myocardial infarction. Onset after 10 days is usually considered Dressler's syndrome. Chest pain caused by pericarditis typically is pleuritic and is accompanied by the auscultatory finding of a pericardial friction rub. Although a pericardial effusion is very common after infarction, it is not pathognomonic of pericarditis. Several investigators have reported on the incidence of pericardial effusion following infarction,[163] [164] [165] [166] [167] as summarized in Table 12-7 . In all the studies reviewed, pericardial effusion was associated with larger infarctions as measured by wall motion scores[163] [166] or degree of creatine kinase elevation.[164] [166] The TABLE 12-7 -- Incidence of Pericardial Effusion After Infarction Study Pierard et al[166] Galve et al[165]
No. of Patients 66 138
No. with Effusion (%) Comments 17 (26) Anterior > inferior 39 (28) Anterior > inferior
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Charlap et al
Pagina 7 di 20
172 30 (17)
Peaked on 3rd day Echo at 72 hr
[164]
Sugiura et al
185 44 (24)
Inferior MIs only; higher incidence with RV infarct Widimsky and 192 82 (43) Peaked 5th day; CHF or [167] Gregor death more common; no increase with thrombolysis or heparin CHF, congestive heart failure; MI, myocardial infarction; RV, right ventricular. [163]
262
incidence of congestive heart failure and mortality is higher in those patients with effusions apparent on echocardiography.[167] In almost all cases the effusions are small and hemodynamically insignificant. Thus, the effusion did not cause the increase in morbidity and mortality but serves as yet another marker of a large infarction. Mitral Regurgitation Ischemic mitral regurgitation can be defined as valvular incompetence associated with myocardial ischemia or infarction in the absence of primary leaflet or chordal pathology (Fig. 12-6) . Acute mitral valve incompetence may occur in the setting of myocardial infarction owing to necrosis and rupture of papillary muscle tissue or incomplete coaptation of the mitral valve leaflets owing to distortion of ventricular architecture. Mitral regurgitation is common in the setting of acute myocardial infarction, with a reported incidence rate between 10% and 50%. Of almost 12,000 postinfarction patients catheterized at Duke University, 19% had evidence of mitral regurgitation by angiography.[168] [169] Hemodynamically significant mitral regurgitation occurs equally in anterior and inferior infarcts. Risk factors for significant postinfarction mitral regurgitation include advanced age, female gender, diabetes, and prior infarction.[170] [171] In patients with myocardial infarction, moderate to severe mitral regurgitation is associated with substantially reduced short- and long-term survival, with up to a 24% early and 54% 1-year mortality rate.[171] [142]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 20
Severe postinfarction mitral regurgitation also is an independent risk factor for coronary artery bypass surgery operative mortality. [168] Moreover, in patients presenting to the emergency room with chest pain, moderate or severe Figure 12-6 (color plate.) Mitral regurgitation in a patient with an inferior myocardial infarction and resultant inferobasal aneurysm. A, Diastolic deformity in this apical two-chamber view (arrow). B, Lack of thickening in this region during systole (arrow). C, Moderately severe mitral regurgitation (double arrow).
mitral regurgitation by echocardiography was associated with high risk for overall and cardiovascular mortality (risk ratio = 2.0).[172] Among these patients, only 60% had audible murmurs. The clinical recognition of mitral regurgitation in the setting of myocardial infarction may be confounded by several variables. Up to 50% of patients with hemodynamically significant mitral regurgitation do not have an audible murmur owing to rapid equalization of left ventricular and left atrial pressures (especially in a low output state) or because the murmur is obscured by lung sounds in a patient with pulmonary edema or mechanical ventilation.[171] In view of the adverse prognosis, early diagnosis is desirable to institute medical or surgical interventions that potentially improve outcome. Although some authors have advocated TTE in all patients admitted with myocardial infarction, this approach is probably not costeffective. However, echocardiography is mandatory in the postinfarction patient with a new systolic murmur, pulmonary edema, or sudden cardiac decompensation. In this situation, TTE is 100% sensitive in detecting mitral regurgitation and in distinguishing mitral regurgitation from ventricular septal defect.[173] Detection and grading of mitral regurgitation is accomplished with 2D, Mmode, color, and spectral Doppler techniques. Two-dimensional imaging detects abnormalities in the mitral valve apparatus, including flail leaflets or ruptured chordae. Although color flow parameters are those most often used, accurate grading of mitral regurgitation severity should encompass other echo-Doppler signs as well.[174] [175] In the patient with pulmonary edema, the unexpected findings of a small infarction, a hyperdynamic left ventricle, increased early mitral inflow velocity, or all three [176] should prompt a careful search for mitral regurgitation even when color flow Doppler mapping is unrevealing.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 20
263
Papillary muscle necrosis with rupture and a flail leaflet is a life-threatening complication of myocardial infarction that requires surgical intervention. The more frequent involvement of the posteromedial papillary muscle is thought to be due to its blood supply from a single coronary artery. Chordae to both leaflets arise from each of the papillary muscles so that in cases of "complete" rupture of the entire trunk of a papillary muscle, both leaflets are affected. In less severe cases, the rupture is "incomplete" and only a single head is torn. The 2D echocardiographic findings include prolapse of one or both leaflets, a flail leaflet, and liberation of a portion of the papillary muscle.[177] In some patients, the ruptured muscle may remain tethered to the chordae and chaotic motion is not present. Spectral and color flow Doppler imaging of the jet is usually easily accomplished with surface imaging, but an eccentric path of flow may complicate its identification. In our experience, TEE is superior in this regard,[36] supported by multiple case reports in the literature[16] [19] [21] (Fig. 12-7) . When only a single head of the papillary muscle is affected (incomplete rupture), medical stabilization often is possible. Initial treatment should include afterload reduction with diuretics, angiotensin converting inhibitors, nitroprusside, and (in cases of severe cardiac decompensation) inotropic support and intra-aortic balloon pump. When rupture is complete, involving the main trunk of the papillary muscle, the complication is uniformly fatal without immediate recognition and prompt repair.[177] [178] In the other forms of ischemic mitral regurgitation, reperfusion therapy with thrombolytics or angioplasty should be considered first-line therapy because reperfusion may improve regurgitant severity and patient prognosis. Coronary bypass in conjunction with mitral valve surgery should be considered in patients who show benefit from medical therapy or nonsurgical revascularization. Coronary bypass with mitral valve surgery is necessary in patients who develop circulatory collapse as a result of mitral regurgitation, despite the relatively high operative mortality in this patient group. In those patients who receive surgery for severe ischemic mitral regurgitation, there is evidence that early surgery, concomitant revascularization, and repair, rather than replacement, improve survival.[179] [180] In the recent SHOCK trial (SHould we use emergently revascularized Occluded Coronaries in cardiogenic shocK?), the survival rate in patients with
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 20
Figure 12-7 (color plate.) Transesophageal echocardiogram of a patient with papillary muscle rupture after an acute inferior myocardial infarction. The papillary muscle rupture was incomplete and the head of the papillary muscle remained tethered to the mitral chordae. A, The triangular density representing the head of the papillary muscle (arrow) can be seen within the body of the left ventricle during systole. B, Associated severe mitral regurgitation with a prominent area of proximal isovelocity surface acceleration (double arrow).
acute severe mitral regurgitation who underwent surgery (40%) was higher than in those treated medically (71%, P < .003).[181] Ventricular Septal Rupture Ventricular septal defect owing to myocardial rupture complicates 1% to 3% of all acute myocardial infarctions and up to 5% of all fatal infarctions. In the GUSTO-1 trial (Global Utilization of Streptokinase and TPA for Occluded coronary arteries), the incidence of ventricular septal rupture was only 0.2% (84 of 41,021 enrolled patients), suggesting that thrombolytic therapy has reduced the incidence of rupture.[182] Ruptures occur only in the presence of transmural infarction and result from hemorrhage within the necrotic zone. Independent risk factors for the development of a ventricular septal defect are similar to those for papillary muscle rupture and include first infarction, advanced age (>65), hypertension, and female gender.[183] [184] There appears to be a higher incidence in patients without a history of prior angina and with infarcts in the distribution of a single vessel.[183] [184] [185] Thus, septal rupture appears to be more likely following abrupt occlusion of a single artery that vascularizes a territory for which there is little collateral flow.[184] Unlike papillary muscle rupture, ventricular septal rupture occurs with equal frequency among patients with anterior (LAD) and inferior (RCA) infarctions but less frequently in those with lateral (left circumflex artery) infarctions.[186] Conflicting evidence exists as to the effect of thrombolytic therapy on the development and outcome of postinfarction ventricular septal defect. Thrombolytic administration that is delayed more than 12 hours following the onset of chest pain may increase the incidence of ventricular septal rupture.[97] However, in most cases the slight increase in the risk of rupture is outweighed by the overall benefit of reperfusion therapy. In the GUSTO1 study, the onset of rupture was earlier on average (1 day) than that reported previously, suggesting that although thrombolytic therapy reduced the rate of rupture, it tended to occur earlier after thrombolysis.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 20
Ventricular septal defects usually present 3 to 6 days after infarction with recurrent chest pain, dyspnea, and sudden hypotension or shock. A new harsh pansystolic murmur is present in approximately 50% of patients. Bedside 264
echocardiography has been demonstrated to be highly sensitive and specific in the diagnosis of ventricular septal defect. The defect can be visualized by transthoracic 2D imaging in 40% to 70% of patients.[177] [187] The use of contrast and color flow Doppler imaging improves the sensitivity to 86% and 95%, respectively.[21] [97] [173] [177] When TTE is suboptimal, TEE is highly accurate with a reported 100% sensitivity and specificity, [188] [189] with improved delineation of the site of defect, the morphology, and presence of multiple defects[190] (Fig. 12-8) . The most common site for a ventricular septal rupture is the posteroapical septum. Visualization of the area of myocardial dropout is most often accomplished in the parasternal short-axis view just below the level of the papillary muscles or in the apical four-chamber view with slight posterior angulation of the probe. Anterior septal defects most often occur in the distal one third of the septum and are visualized in the apical four-chamber view with anterior angulation or in an apical short-axis view. Postmyocardial infarction ventricular septal defects may be multiple and often have a serpiginous course through the myocardium.[191] Associated echocardiographic findings include evidence of elevated right ventricular pressure including right ventricular dilation, decreased right ventricular systolic function, and paradoxical septal motion. Signs of increased right atrial pressure include right atrial dilation, bowing of the interatrial septum toward the left throughout the cardiac cycle, and plethora of the inferior vena cava. Color flow Doppler imaging is particularly useful in demonstrating the exact position of the defect; the width of the jet correlates with the size of the defect as measured at surgery.[191] Although the peak gradient across the ventricular septal defect measured with continuous wave Doppler allows an estimate of right ventricular systolic pressure, the measurement should be used with caution in patients with complex defects involving indirect tracts through the myocardium. [191] A recent study demonstrated a fair correlation between this Doppler estimate of right ventricular systolic pressure and that measured at catheterization (r = 0.71); the values were similar to those estimated from the tricuspid
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 20
regurgitant jet. Echocardiography provides prognostic and diagnostic information in patients with ventricular septal rupture. Rupture Figure 12-8 (color plate.) Transesophageal echocardiogram showing a large ventricular septal defect (VSD) involving the posterior septum in a patient with a large inferior myocardial infarction and right ventricular extension. Left, The area of discontinuity can be visualized as a large, irregularly shaped area of myocardial dropout. Right, Color flow demonstrates left-to-right shunting across this ventricular septal defect. LV, left ventricle; RV, right ventricle.
of the posterior septum after inferior myocardial infarction is associated with a higher mortality rate, apparently related to the degree of associated right ventricular dysfunction.[186] [192] Moreover, posterior septal ruptures tend to be more complex and associated with remote myocardial involvement. In contrast, anterior septal defects more often have a direct course and involve a discrete myocardial region. Overall mortality is 95% to 100% without surgical intervention.[193] The strongest indicator of poor prognosis is the development of cardiogenic shock associated with as much as a 90% mortality rate.[192] Although early surgery appears to improve survival when cardiogenic shock is present, results in the recent SHOCK trial were disappointing. In the surgically treated group, the survival rate (19%) was only slightly better than that of the medically treated group (5%).[186] Right ventricular systolic pressure tended to be higher and right atrial pressure lower, among the survivors. When the patient can be stabilized medically, operative mortality may be improved when surgical repair is delayed until 6 weeks following the event.[184] In summary, the value of echocardiography in patients with suspected ventricular septal rupture is its ability to provide an accurate, timely diagnosis and important prognostic information that may assist in therapeutic decision making. Rupture of the Ventricular Free Wall and Pseudoaneurysm Free wall rupture occurs in approximately 3% of all acute myocardial infarctions,[194] and it is one of the leading causes of fatality (8% to 20%).[195] [196] [197] [198] [199] Risk factors for free wall rupture are similar to those for papillary muscle and ventricular septal rupture; however, this complication is more likely to occur in patients with a transmural myocardial infarction involving the posterolateral wall associated with a left circumflex occlusion
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 20
or with a LAD occlusion.[201] Early successful reperfusion appears to decrease the risk of rupture. In one study of approximately 1300 patients, the overall incidence of cardiac rupture was lower in those receiving thrombolytic therapy (1.7%) than in those in the conventional therapy group (2.7%). Among
[200]
265
patients who receive thrombolytic therapy, patients older than 70 years of age and women had higher rates of rupture.[202] Moreover, patients in whom reperfusion was unsuccessful had a significantly higher rate of rupture than those who were successfully reperfused (5.9% versus 0.5%).[203] Conversely, late reperfusion appears to increase the risk of myocardial rupture though decreasing overall mortality.[97] [204] The use of nitrates in acute myocardial infarction may decrease the risk of rupture by as much as 30%.[205] The intensity of post-thrombolytic anticoagulation with heparin or hirudin does not appear to affect the rate of rupture. [202] Although ventricular free wall rupture usually presents clinically as an acute catastrophic event leading to rapid demise, several recent pathologic and clinical studies have suggested that many cases may involve subacute dissection and tearing of the myocardium before hemodynamic collapse.[194] [196] [200] [205] , Intramural hematoma or hemorrhage at the junction of the necrotic and the normal myocardium results in a small endocardial rent. The tear usually takes a circuitous pathway through the myocardium, ending in a small epicardial opening. Clinically, a prodrome of ongoing or recurrent chest pain (in the absence of an elevation in creatinine kinase), repetitive large volume emesis, unexplained agitation, hypotension or syncope may be associated with the initial small tear.[194] [196] [200] A small amount of hemorrhage into the pericardial space of blood may precede the final catastrophic event. Patients diagnosed during this subacute phase and taken promptly to surgery have a greater chance of survival. A second mechanism of rupture through the wall of an aneurysm has been described. [206]
Echocardiography has a high sensitivity for rupture[194] when the diagnosis is sought and all the echocardiographic findings are considered. The most frequent finding is pericardial effusion; the absence of pericardial effusion virtually excludes rupture. Increasing size of effusion and the presence of thrombus in the pericardial space significantly increases the specificity for rupture (>98%). [194] [204] , [207] An intrapericardial thrombus appears as an
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 20
echo-dense mass; it may be mobile, undulating within the pericardial space or immobile, impinging on the cardiac chambers.[208] Direct visualization of the myocardial tear is possible with TTE in as many as 40% of patients.[201] Other echocardiographic findings include evidence of Figure 12-9 The difference between a true aneurysm (A) and a false aneurysm (B). Note that in the true aneurysm there is continuity of myocardium in the region of dilation, in contrast to the loss of this continuity in the pseudoaneurysm. (Modified from MacKenzie JW, Lemole GM: Tex Heart Inst J 1994;21:296–301.)
tamponade with right atrial and right ventricular diastolic collapse (40%), [201] respiratory variation of the tricuspid and mitral inflow pattern, and plethora of the inferior vena cava. Echocardiographic guidance of pericardiocentesis of the hemopericardium may be life saving in the patient with hemodynamic collapse before the patient can be transported to surgery. Patients at risk for rupture may be identified by evidence of infarct expansion with significant wall thinning at the infarct site. The mortality rate of free wall rupture in the absence of surgical intervention approaches 100%,[199] although recent series report as much as a 50% survival rate in patients who underwent pericardiocentesis and conservative medical management.[201] [209] The in-hospital mortality rate for those who undergo surgical repair is in the range of 40%.[193] [201] [204] Those who survive until hospital discharge appear to have a good long-term prognosis. Thus, early echocardiographic diagnosis with prompt surgical or percutaneous drainage is mandatory in patients who develop postinfarction myocardial rupture. A pseudoaneurysm is a myocardial rupture contained by pericardial adhesions resulting in a pouch that communicates with the left ventricular cavity. [177] A distinguishing echocardiographic feature is the narrow neck, compared with the broader "entrance" to the body of a true aneurysm, with a "neck" diameter-to-maximum diameter ratio less than 0.5. An echocardiographic study showed that this sign was only 60% sensitive in patients with post-myocardial infarction pseudoaneurysms.[210] The majority of post-myocardial infarction pseudoaneurysms were located in the inferoposterior or posterolateral regions (associated with right coronary or left circumflex coronary occlusions).[210] The walls of the pseudoaneurysm are composed of pericardium rather than
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 15 di 20
the thin-walled myocardial scar of true aneurysm (Fig. 12-9A) . Occasionally a pseudoaneurysm may occur after rupture of the thin wall of a true aneurysm with the development of a "mixed" aneurysm (see Fig. 129B) . [211] Spectral and color Doppler imaging demonstrate characteristic flow in and out of the pericardial cavity at the site of the tear, as well as abnormal flow within the pseudoaneurysm. Respiratory variation of the peak systolic velocity has also been demonstrated.[212] A meta-analysis suggested that TEE has a higher diagnostic accuracy (>75%) than TTE (26%), although data 266
was available in only a small number of patients[213] (Fig. 12-10) . Surgical repair is the preferred treatment, although new reports have demonstrated that conservative medical treatment in certain high-risk patients is not associated with an increased risk of cardiac rupture.[210] [213] Infarct Expansion and Aneurysm Formation Infarct expansion is an increase in the circumferential extent of the area of infarction that results from stretching and thinning of the infarcted zone. Early clinical studies demonstrated that this phenomenon with a consequent increase in left ventricular volume and wall stress was associated with an adverse prognosis.[85] The importance of infarct expansion has been underscored by clinical trials using angiotensin converting enzyme inhibitors in patients with left ventricular dysfunction after myocardial infarction. In the SAVE trial (Survival and Ventricular Enlargement), which showed a 21% reduction in cardiovascular mortality with the use of captopril,[214] echocardiography demonstrated that ventricular enlargement and reduced fractional area change were independent risk factors for cardiac events. Patients treated with captopril had a lower incidence of ventricular enlargement, which was associated with the lower risk of events,[50] a finding that has been confirmed in subsequent studies.[141] [215] The final expression of infarct expansion is aneurysm formation. In the Coronary Artery Surgery Study (CASS) there was a 7.6% incidence of angiographically documented left ventricular aneurysms.[216] In a study by Visser et al,[218] the incidence of aneurysm was 22% (35 of 158), and most of those occurred in patients with anterior infarction. Formation of an aneurysm occurs only with transmural infarction with a full-thickness scar and, thus, is more frequent following a Q-wave than a non-Q-wave
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 16 di 20
infarction. An aneurysm is more likely to complicate an infarct in the LAD distribution than in the right or circumflex arteries.[218] Spontaneous rupture of an acute aneurysm is rare (see "Rupture of the Ventricular Free Wall"), and late rupture virtually never occurs. Serial 2D echocardiographic studies show that aneurysmal dilation is present as early as 5 days after myocardial infarction (15 of 35, 43%, in the Visser study), and new aneurysms after 3 months are unlikely.[218] Despite the Figure 12-10 Transgastric views in transesophageal echocardiogram showing a large pseudoaneurysm involving the inferolateral wall. Left, short-axis view (horizontal plane); right, long-axis view (longitudinal plane).
beneficial clinical course attributed to delayed reperfusion with thrombolytic therapy, there has been no reduction in the frequency of ventricular aneurysms.[219] [220] The echocardiographic appearance of a ventricular aneurysm parallels the pathology. A true aneurysm is defined as a deformity of the thinned infarct segment that is apparent during diastole as well as during systole (see Fig. 12-6) and demonstrates a diastolic contour abnormality. In contrast, a dyskinetic myocardial segment deforms during systole, extending beyond the normal contour of the myocardium. The involved myocardial segment is scarred with thin walls (<7 mm) and increased echogenicity owing to the increased collagen content. [114] The wall of the aneurysm may eventually calcify. The most common location is the left ventricular apex, which is involved in approximately 90% of patients. Aneurysms may vary in size, and very small aneurysms may be difficult to visualize by echocardiography. Technically, the detection of an apical aneurysm is highly dependent on the skill of the operator. Routine employment of highfrequency transducers with a shallow focal point enhances near-field resolution and aids examination of the left ventricular apex. Left-sided contrast agents also may enable detection of small apical aneurysms. Using these methods, the sensitivity of TTE for detection of apical aneurysms should approach 100%. Occasionally, spontaneous echocardiographic contrast may be visible in large aneurysms. It should be noted that TEE may not provide adequate visualization of the left ventricular apex and, therefore, in our experience, is less sensitive than surface imaging.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 17 di 20
Echocardiographic recognition of a left ventricular aneurysm is clinically relevant for the following reasons: 1. The early formation of an aneurysm adversely affects early (inhospital) and late (1 year) mortality.[218] 2. Thrombi are frequently found within aneurysms. 3. Aneurysms and left ventricular thrombi are associated with systemic embolization. In patients with refractory heart failure and angina or recurrent embolic events, aneurysmectomy may be recommended occasionally. Functional measurements of the residual myocardium using quantitative 2D echocardiography is highly predictive of operative mortality and the clinical success of this procedure.[221] [222] A basal (residual) ejection fraction of greater than 40% was associated with a satisfactory result.[222] Left Ventricular Thrombus
267
Studies in the early 1980s demonstrated a high sensitivity (90% to 95%) and high specificity (80% to 85%) for the echocardiographic identification of left ventricular thrombus.[223] [224] A prerequisite for thrombus formation is the presence of a segmental wall motion abnormality, most commonly in the left ventricular apex. The ultrasonic appearance of a mural thrombus is that of a mass distinct from the endocardium and protruding to a variable extent into the left ventricular cavity. Under ideal conditions, the surface of the thrombus can be distinguished clearly from the underlying endocardium and the mass can be visualized in two different imaging planes. The tissue characteristics of an acute thrombus are usually similar to that of the myocardium (Fig. 12-11) . A chronic thrombus may have increased reflectivity, demonstrate a layered appearance corresponding to the lines of Zahn, and contain areas of calcification (Fig. 12-12) . The base of attachment to the wall may be broad in the case of a sessile thrombus and narrow in a pedunculated thrombus. When multiple characteristics of the thrombus are analyzed, mobility of the thrombus is most closely associated (positive predictive value, 85%) with embolic events.[220] [225] In any given patient, the morphology may spontaneously change from sessile to pedunculated and vice versa; mobility may resolve spontaneously.[226] False-positive echocardiographic diagnoses are usually a result of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 18 di 20
pseudotendons (i.e., false chordae) spanning the left ventricular apex, coarse trabeculations associated with left ventricular hypertrophy, or nearfield artifacts (commonly present with low-frequency transducers). Highfrequency transducers with a short focus point can sometimes differentiate true thrombus from these other phenomena. Left-sided contrast agents may outline the contours of the thrombus, creating a filling defect[227] [228] with improved detection of thrombus. Thrombi most commonly develop in the presence of a large infarction during the hospitalization phase of a Figure 12-11 Acute thrombus in the posterior aspect of the apical septum. Note that the large mass is homogeneous in texture, without evidence of calcification.
Figure 12-12 Four-chamber view depicting a chronic thrombus within an apical aneurysm. The appearance of the thrombus is layered with areas of calcification. The layers correspond to the lines of Zahn.
myocardial infarction.[229] Like aneurysms, they are more likely following a myocardial infarction in the LAD (up to 33%) than in the RCA or left circumflex artery distribution (less than 1%).[230] [231] New data demonstrate that the best predictor of left ventricular thrombus formation after acute anterior myocardial infarction is a high initial end-systolic volume.[232] Anticoagulant therapy appears to decrease the risk of embolic events and enhances the resolution of thrombus, although spontaneous resolution also may occur.[229] [233] Patients with a left ventricular thrombus identified during the initial hospital stay have an increased long-term mortality rate (22%) compared with those without thrombi (7%). Left ventricular thrombi usually resolve during the first month after anterior myocardial infarction with routine thrombolytic and aspirin treatment, but appearance and resolution of thrombi can continue in a significant proportion of patients (12%).[234] In general, thrombolytic therapy appears to decrease the rate of mural thrombus development. In the Western Washington Randomized Trial of intracoronary streptokinase, the incidence of thrombus and emboli was similar in both treated and untreated groups,[219] but most other trials of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 19 di 20
intravenous thrombolytic agents have shown a reduction in the incidence of thrombi and emboli.[235] [236] [237] [238] Moreover, in the GISSI-2 trial there was no significant difference between the four treatment groups (recombinant tissue plasminogen activator ± heparin, streptokinase ± heparin), with an overall incidence of 28%.[239] The overall tendency for reperfusion therapy to decrease the size of the infarction is likely to lower the risk of thrombus formation. In addition, after thrombolysis, most patients receive an inhospital period of anticoagulation, which is known to decrease the rate of thrombosis and embolization[239] (Table 12-8) .
268
TABLE 12-8 -- Effect of Thrombolytic Therapy on Incidence of Left Ventricular Thrombus in Anterior Wall Myocardial Infarction Study Eigler et al
No. of Patients Agent 22 SK
Mean Time Treated Untreated to Rx (hr) (%) (%) P <3 1/12 (8) 7/10 (70) <.005
[235]
Stratton et al
83 SK *
[219]
Natarajan et al[237] Lupi et al[236] Bhatnagar and al-Yusuf
45 SK 63 SK 118 r-TPA
4.7 7/45 6/38 (16) (16) <6 0/27 (0) 8/18 (44) ≤3 4/19 (22) <4 3/54 (5.5)
NS <.05
30/44 (54) <.05 8/44 (18) † <.05
[238]
NA 34/74 10/25 (40) NS (46) Domenicucci 222 SK, NA 26/97 71/125 <.005 [240] et al alteplase (27) (57) NA, not available; NS, not significant; r-TPA, recombinant tissue plasminogen activator; SK, streptokinase. Mooe et al
99 SK
[234]
*Intracoronary. †Received heparin.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 20 di 20
The decision to prescribe oral anticoagulation following hospital discharge is influenced by two additional considerations. Embolic events occur most likely in the first month after myocardial infarction and rarely occur in the absence of thrombus identified by echocardiography.[240] However, the risk of cerebral or systemic embolization after infarction is increased in patients with large apical aneurysms and poor systolic function independent of echocardiographically documented mural thrombus. Second, chronic mural thrombi, persistent for more than 3 months following a myocardial infarction, are very unlikely to embolize. Changes in the morphology of the thrombus with evidence of protrusion are most likely to predict late embolism (>3 months).[240] Thus, most physicians perform an echocardiogram during the acute phase of an anterior wall infarction to measure left ventricular function and to detect aneurysm, thrombus, or both. In the presence of a large apical aneurysm with or without a visible thrombus, oral anticoagulation is recommended in the absence of contraindications.[241]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/106.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Post-Myocardial Infarction Risk Stratification Echocardiography has an important role in the evaluation of a patient after discharge from the CCU. Echocardiography during low-dose dobutamine infusion is used to detect myocardial viability in segments that have persistent dysfunction following reperfusion.[64] Echocardiography during higher dose dobutamine infusion or with dynamic stress can be used to detect residual ischemia. Caution should be exercised in the first week after a transmural infarction because cases of myocardial rupture during highdose dobutamine infusion have been reported.[28] [29] Contrast echocardiography will have an important role with the development of reliable perfusion agents.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/107.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Summary Early experimental models employing echocardiography for the detection and quantitation of ischemia and infarction helped investigators elucidate the pathophysiology. This work was directly transferable into the CCU and provided the basis for the clinical diagnostic and prognostic role of echocardiography. Advances in echocardiography, especially color flow Doppler imaging, increased the capabilities of echocardiography in detecting the occurrence of complications, such as ventricular septal defect and papillary muscle rupture. Future directions include the detection of flow deficits using myocardial contrast echocardiography and more accurate quantitation of infarct size using 3D techniques.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/108.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
275
Chapter 13 - Exercise Echocardiography Stress Testing in the Initial Diagnosis of Coronary Artery Disease and in Patients with Prior Revascularization or Myocardial Infarction Pamela A. Marcovitz MD
Stress echocardiography consists of a number of stress techniques used in conjunction with echocardiographic imaging. Exercise echocardiography is the most established of these techniques and has been increasing in popularity since the first paper was published on the use of twodimensional echocardiography with bicycle exercise in 1979.[1] Although the images were crude, they served to successfully demonstrate ischemia following cardiovascular stress and its resolution following coronary artery bypass grafting (Fig. 13-1) (Figure Not Available) . With technologic advances, including improvements in imaging and digitization, stress echocardiography has seen widespread acceptance as a first-line technique for the diagnosis of coronary disease. Recently, stress echocardiography has been increasingly used for prognostication in various patient subsets, including patients with chronic coronary disease, patients with recent revascularization, patients with recent myocardial infarction, and female patients. Despite recent advances, however, the principles of its use remain
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
the same. In the presence of a significant coronary stenosis, an adequate level of physical exertion results in a transient mismatch between oxygen supply and demand, resulting in a wall motion abnormality within an area of myocardium supplied by a stenotic artery. The wall motion abnormality is detectable by echocardiography and serves as a marker of the degree and severity of ischemia. Future advancements may bring the ability to simultaneously track myocardial perfusion.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/111.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 3
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Rationale and Theoretical Basis for Ischemia Detection with Stress Echocardiography The rationale for the use of echocardiography to detect ischemia in conjunction with stress testing is that ultrasonography can visualize wall motion abnormalities that arise as the result of a transient mismatch between oxygen supply and demand, in turn resulting in ischemia.[2] [3] [4] [5] Regardless of the stress modality used to induce ischemia, the echocardiographic response to exercise will reflect the underlying state of the coronary arteries.[6] [7] [8] [9] In the absence of coronary artery disease, there will be inward motion (endocardial excursion of at least 5 mm) and increased wall thickening. These characterize the "normal hyperdynamic response" following exercise and signify normal underlying coronary arteries. Conversely, in myocardium subtended by a critical stenosis, a mismatch between oxygen supply and demand will develop during exercise, resulting in ventricular systolic dysfunction or dyssnergy, in a segment or segments of myocardium during cardiovascular stress. Dyssynergic responses may be classified by the degree of abnormality present: 1. Hypokinesia: less than normal (5 mm) degree of inward myocardial excursion and thickening 2. Akinesia: complete lack of inward motion and thickening 276
3. Dyskinesia: paradoxical outward motion and thinning of affected segment or segments. Figure 13-1 (Figure Not Available) Images from a 30-degree sector scanner demonstrating an exercise-induced apical abnormality prior to coronary artery bypass grafting (A) and normal apical wall motion after revascularization (B). (From Wann LS, Favis JV, Childress RH, et al: Circulation 1979;60:1300–1308. Reproduced with permission. Copyright 1979 American Heart Association.)
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 3
The observation that abnormal wall motion reflects an underlying mismatch in supply and demand serves as the premise for the use of echocardiographic imaging in stress testing and occurs during a variety of states in which oxygen supply to the myocardium is reduced. Using a stylus attached directly to myocardium in an animal model, Tennant and Wiggers [10] were among the first to demonstrate that disruption of the coronary blood supply produces wall motion abnormality. Immediately after snare occlusion of a coronary artery, a reduction in wall thickening was observed, followed by normalization of wall motion along with release of the snare. This observation has since been validated with echocardiography in clinical settings in which arterial occlusion occurs, including balloon angioplasty and myocardial infarction.[11] [12] A variety of models have been studied to determine, in detail, the temporal and spatial sequence of events that occur during decreased regional blood flow of sufficient severity to create an imbalance in the myocardial oxygen supply-demand relationship. These models have included graded snare coronary occlusion in animals, balloon angioplasty, exercise, atrial pacing, and observation of spontaneous anginal episodes in humans.[13] [14] [15] [16] [17] [18] [19] In the early animal studies, a closely coupled relationship was noted between myocardial wall thickening and coronary flow, such that reductions in blood flow of 10% to 20% were found to impair regional (but not global) wall thickening within an ischemic zone. The observed reduction in wall thickening was found to be proportional to severity of flow reduction, with greater degrees of flow restriction causing greater severity in regional wall motion abnormalities.[16] , [20] Thus, whereas hypokinesis is noted following a threshold reduction in blood flow of around 10% to 20%, akinesis is observed with flow reduction of greater than 80%, and paradoxial motion, or dyskinesis, with transmural reductions in flow. These early studies also noted a tendency for decreased wall thickening to be more closely coupled with subendocardial rather than subepicardial flow and to extend into adjacent regions beyond welldemarcated zones of reduced flow, a phenomenon known as tethering.[3] [21] As the opportunities for echocardiographic monitoring grew, these observations in animals were extended to humans.[22] [23] [24] [25] Taken together, these studies form the basis for what we now regard as standard echocardiographic observations of ischemic myocardium. After acute, complete coronary occlusion, a series of predictable changes takes place in the myocardium, beginning with the development of diastolic and systolic dysfunction, followed by ST segment depression and angina. A
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 3
wall motion abnormality is one of the initial events seen with the development of ischemia and precedes development of ST segment changes or angina by several minutes. This so-called ischemic cascade, which is known to occur after occlusion of a coronary artery, may occur in ischemic myocardium subtended by a critical stenosis whenever oxygen supply-demand mismatch occurs.[26] [27] [28] A similar temporal relationship between wall motion and electrocardiographic changes has been noted in multiple studies of patients undergoing balloon angioplasty.[12] [29] [30] [31] Hauser et al[31] noted that regional endocardial dysfunction was seen by echocardiography at 19 seconds, electrocardiographic changes occurred at 30 seconds, and chest pain occurred at 39 seconds after balloon inflation. In addition to clinical settings involving coronary occlusion, the "ischemic cascade" was found to occur in ischemic myocardium subtended by a severe stenosis subjected to cardiovascular stress. Examining changes following exercise-induced ischemia in the region of a coronary stenosis, Sugishita et al[28] noted that the average time to onset of wall motion abnormality was 30 seconds, versus 90 seconds for electrocardiographic changes. Clinically, the ability to detect exercise-induced regional wall motion abnormalities increases with the severity and number of coronary occlusions.[32] [33]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/112.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 20
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Diagnostic Approach Choosing the Optimal Form of Stress
277
Exercise is one of a number of stress modalities performed in conjunction with echocardiographic imaging. An adequate level of stress is a prerequisite to performing exercise echocardiography. For the purposes of stress testing, clinically adequate exercise is usually defined as the ability to reach at least 85% of predicted heart rate, based on resting heart rate and age. For patients able to exercise maximally, exercise echocardiography provides a wealth of information regarding the overall level of fitness, functional capacity, and the clinical significance of an ischemic response, as well as the prognosis related to coronary disease. Given the additional diagnostic and prognostic information provided by exercise and hemodynamic parameters, exercise should be the stress method of choice whenever feasible. In the event that a patient cannot perform adequate exercise, other stressors are used (Table 13-1) . For patients unable to perform maximal exercise or to reach a target heart rate, pharmacologic methods of inducing stress are commonly used. These are discussed in greater detail in Chapter 14 , but briefly, currently available pharmacologic methods can be divided into one of two general categories: agents that simulate exercise and coronary vasodilators. [34] The first of these are sympathomimetic amines, are infused intravenously, and induce stress in similar fashion to exercise, that is, through increasing heart rate, blood pressure, and contractility. Of the exercise-simulating agents, dobutamine has emerged as the agent of choice in the United States, largely because of its availability and low cost. Dobutamine exerts its physiologic effects through beta agonist activity, increasing myocardial oxygen demand in a similar fashion to exercise. Unlike exercise, however, dobutamine is unable to provide information about level of fitness or electrocardiographic or
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 20
hemodynamic response to exercise. In addition, TABLE 13-1 -- Stress Modalities Used with Echocardiographic Imaging Exercise Treadmill Supine bicycle Upright bicycle Lateral bicycle Pharmacologic stress Dobutamine Dobutamine-atropine Arbutamine (not currently available) Epinephrine Isoproterenol Dipyridamole Dipyridamole-dobutamine Adenosine Pacing Esophageal Atrial Other Hand grip Cold presser Mental stress Hyperventilation Postventricular beats dobutamine frequently does not cause an adequate rise in heart rate, and for this reason, atropine is often needed to increase myocardial oxygen demand.[35] [36] Despite these drawbacks, dobutamine can provide information about the presence or absence of coronary disease, which is valuable in patient management decisions and prognostication. Arbutamine, which is the only pharmacologic stress testing agent approved by the Food and Drug Administration, provides a more balanced heart rate and blood
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 20
pressure response without the need for atropine.[37] [38] Because of cost, however, and because it did not provide a clear advantage over dobutamine, Arbutamine was withdrawn from the market. Isoproterenol, because it produces extreme tachycardia, is no longer used as a stress agent. Atrial pacing, sometimes employed via a transesophageal approach, is reliable but is cumbersome and uncomfortable for the patient and therefore rarely used. Vasodilators, such as dipyridamole and adenosine, create ischemia through the mechanism of coronary steal, or the selective dilation of nonstenotic coronary beds. Following administration of these agents, normal coronary beds dilate preferentially in relation to stenotic beds, in effect shunting flow away from stenotic beds and rendering them ischemic. Some experts believe, and the medical literature suggests, that echocardiography has a lesser sensitivity for the detection of coronary disease when vasodilators are used, as compared with exercise and dobutamine.[39] [40] [41] Nonetheless, dipyridamole continues to be used for the detection of coronary disease, chiefly outside the United States, where the cost of this agent is lower. The type of stress one chooses to apply in conjunction with echocardiography should be based on the patient's ability to exercise and the diagnostic information one wishes to gain from testing. For example, for the initial diagnosis of coronary artery disease in a patient whose chest pain is provoked by physical exertion, exercise would be preferred. For patients unable to exercise maximally because of arthritis, peripheral vascular disease, or general deconditioning, pharmacologic stressors are more appropriate. Rarely, chest pain may be believed to be provoked by vasospasm, and for those patients whose chest pain is suspected to be vasospastic, ergonovine or hyperventilation may be appropriate.[42] [43] The choice of stress should also be governed by the patient's familiarity with types of activities. In the United States, the most popular form of applied physical stress for the purposes of diagnostic testing for coronary disease remains treadmill exercise. Familiarity with walking may lead to achievement of higher cardiovascular workloads. In European countries, upright bicycle exercise is a more familiar activity and has assumed a prominent role. More recently, the supine bike, sometimes with lateral angling, is emerging in the United States as a popular technique for assessment of coronary artery disease. Supine bicycle exercise facilitates imaging whenever a continuous record of echocardiographic images is desired. In the diagnosis of coronary disease, bicycle exercise allows one to determine more precisely the level of exercise at which ischemia develops,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 20
which, as discussed later, may be advantageous in the serial assessment of patients. Bicycle exercise also facilitates assessment of the clinical significance of valvular 278
Figure 13-2 Stress echocardiography laboratory equipment set-up, beginning in the lower left-hand corner and moving clockwise: crash cart, frame grabber, echocardiography machine, bed with shelf above for pulse oximeter and automated blood pressure cuff, electrocardiographic monitoring machine, blood pressure (BP) cuff (manual), treadmill, intravenous (IV) infusion pump for pharmacologic stress echocardiography, and IV equipment. The room measures 15 × 18 feet and requires no more than two steps for the patient between treadmill and bed.
heart disease and pulmonary hypertension through assessment of Doppler jets at various workloads. Equipment, Methodology, and Personnel The equipment needed for exercise echocardiography partially depends on the type of stress applied in conjunction with echocardiography. In all cases, high-quality echocardiographic instrumentation with an integrated or free-standing digital frame grabber, an offline analysis system, and either a treadmill or bicycle (supine or upright) connected to a computerized 12lead electrocardiograph are required. The ergonomics of the stress echocardiography laboratory should facilitate moving from the imaging bed to the treadmill and back to the imaging bed immediately after exercise in as few steps as possible. Following the use of any standard treadmill protocol, the patient steps off the treadmill and onto the imaging bed. Extra steps spent between equipment may result in a critical loss of imaging time during the immediate postexercise period, leading to loss of sensitivity. Thus, the most critical period of time in performing exercise echocardiography is that spent between the termination of exercise and the start of imaging. A typical floor plan for a stress echocardiography laboratory that requires a minimum number of steps for both patient and technician-sonographer is shown in Figure 13-2 . The set-up shown in Figure 13-2 rarely requires multiple steps for the patient between the treadmill and imaging bed. Imaging should take place as quickly as possible, since it has been shown that information about ischemia, particularly single-vessel disease, will be lost as the heart rate returns to
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 20
normal. Some experts believe that special imaging beds with lateral cut-outs for apical imaging facilitate image acquisition. Images are typically captured in four views for side-by-side comparison in a digital format. The parasternal long- and short-axis and apical four- and two-chamber views have traditionally been used, with the substitution of subcostal images, if necessary, for patients with chronic obstructive pulmonary disease or postbypass surgical bandages that interfere with imaging windows.[44] Modification of chest lead placement is sometimes necessary to 279
obtain the best imaging windows and rarely interferes with the integrity of the electrocardiographic response. The question of whether to perform a complete baseline study with Doppler imaging or to simply capture the minimum number of images required for stress imaging often arises. In our laboratory, the practice is to perform a complete baseline study unless one has recently been performed and there has been no interim change in the patient's clinical status. The personnel required to perform exercise echocardiography varies in different laboratories depending on local standards of practice, hospital regulations, and level of billing. In most cases, at least two people are required to carry out exercise echocardiography: a technician-sonographer to perform the imaging and a second technician to monitor the patient's hemodynamic, electrocardiographic, and symptomatic responses to exercise. Regardless of the type of exercise used (i.e., treadmill or bicycle), a sonographer records baseline images at rest, followed by images during or immediately after peak exercise, while a monitoring technician notes and records the hemodynamic and electrocardiographic responses to exercise. At the completion of exercise, the monitoring technician assists the patient in quickly stepping off the treadmill or upright bicycle and reassuming the left lateral decubitus position for postexercise and recovery images, which take place on an imaging table or bed. Alternatively, a nurse or a physician may monitor and assist the patient. One advantage to physician monitoring is that it allows for immediate image interpretation of poststress images. Some laboratories use registered nurses trained as sonographers for both imaging and monitoring functions, eliminating the need for two staff members. Depending on local standards of practice, some hospital laboratories require physician presence in all cases, either in the stress
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 20
echocardiography room itself, or within the immediate area. In our hospital's echocardiography laboratory, all pharmacologic stress tests and high-risk patients referred for exercise tests are supervised directly by a physician. Outpatient clinic echocardiographic laboratories are growing in number. The equipment is the same as for hospital laboratories, but often one technician performs both monitoring and imaging functions, with a physician available within a few steps of the laboratory. The need for frequent hemodynamic monitoring will be facilitated by the use of an automated blood pressure cuff. Obviously, it is best not to perform exercise echocardiography on high-risk patients in this setting. The safety of exercise echocardiography is comparable to the safety of other stress testing modalities. A reported mortality rate of 1 in 10,000 patients with adverse events ranging from 4 to 9 in 10,000 are reported for stress electrocardiography, echocardiography, and nuclear scintigraphy.[45] [46] [47] [48] As with any form of stress testing, a crash cart should be kept within the vicinity of the testing area. Outpatients referred to hospital laboratories may not be well known to the staff performing the test, and for safety reasons, heart rate–lowering medications such as beta blockers and calcium channel blockers are sometimes continued. A question occasionally arises about whether to stop a patient's beta blocker prior to testing, since rapid decay of heart rate response after discontinuing exercise is largely responsible for loss of wall motion information. This may create the problem of achieving a submaximal test because of inadequate heart rate response. One potential solution in clinically stable patients is to decrease their beta blocker dose on the evening prior to testing to one-half dose, and to hold beta blockers on the morning of the test. This simple protocol often allows patients to minimize the antichronotropic effects of beta blockade while still retaining some measure of safety with a weaning protocol. Analysis of poststress images has been greatly facilitated by online digitization of images, which allows side-by-side comparison of views.[6] [49] [50] Prior to the development of digital images, the feasibility was lower— around 70%—for successful imaging in an unselected population owing to motion and respiratory artifact. With the advent of digital techniques, feasibility has risen to well over 90% in experienced laboratories. Frame grabbers for digital display allow selection of the optimal images out of multiple cardiac cycles, after all images are obtained. Thus, the technician
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 20
is able to select images without lung interference after all imaging is completed. Asking the patient to perform a breathing maneuver for 2 to 5 seconds during acquisition is another technique that facilitates obtaining high-quality images devoid of respiratory artifact. This maneuver, which works best when practiced during baseline imaging, involves asking the patient to exhale completely or "take in a half breath" and hold his or her breath for a few seconds during the postexercise images. Following optimal image selection, which may be performed by the physician or an experienced sonographer, images are then displayed in side-by-side format with prestress and poststress images adjacent to each other for comparison, generally in right-to-left fashion (Fig. 13-3) . Side-by-side comparison of segments in a gated format facilitates recognition of more subtle abnormalities, raising diagnostic accuracy. Most digitization systems acquire loops of eight frames for each view, with 50 msec allowed for each frame. This time period allows for systolic frames, with a limited portion of diastole, to be captured by triggering image acquisition at the beginning of the R wave of the electrocardiogram. Eight frames are then displayed in a continuous loop format for playback. Imaging acquisition time should be of sufficient duration to digitize all four views but must be performed quickly enough to visualize transient wall motion abnormalities, lest important information be lost as ischemia quickly resolves. Approximately 10 to 20 seconds are needed for digital capture of each view. Ideally, all four views can be digitally captured in approximately 1 minute. In our laboratory, postexercise apical views are captured first to facilitate recording wall motion in distal coronary territories, which are most likely to display ischemic abnormalities. A videotaped recording is made for back-up, and review of these images is recommended to ensure that the captured images are representative of the videotape. Treadmill Exercise Echocardiographic Protocol The most popular form of stress used in exercise echocardiographic testing in the United States is treadmill 280
Figure 13-3 Quad-screen format depicting parasternal long-axis and shortaxis views. Diastolic frames (DIAS) and systolic frames (SYS) at baseline (PRE) and immediately after treadmill exercise (POST) are shown. The
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 20
ventricular response is normal after exercise, with increased endocardial excursion and increased wall thickening in all visualized segments.
exercise, partly because of the familiarity of walking as a form of exercise and partly because of improved image quality over that of bicycle protocols. Analysis of images depends on the direct comparison of preexercise and postexercise images. Parasternal long-axis, short-axis, fourchamber, and two-chamber images are obtained at rest both on videotape and, as noted previously, on an eight-cell cine loop for display in a side-byside quad-screen format at 50 msec per frame. In our laboratory, a complete baseline study with Doppler examination is usually performed simultaneously. The patient is then asked to step onto the treadmill and to begin exercise on one of various standard protocols available. The Bruce protocol is the most commonly used protocol, but the modified Bruce or the Cornell protocol are options for patients who are not in optimal cardiovascular condition or who require a longer warm-up period. Once baseline images are obtained, treadmill exercise proceeds in usual fashion, limited by symptoms, significant electrocardiographic changes, or a predetermined maximal exercise capacity. After cessation of exercise, the patient steps off the treadmill and reassumes the left lateral decubitus position for 281
Figure 13-4 Wall motion score index incorporating a 16-segment model using the scoring system depicted at the top. Numbers 5 and 7 are arbitrarily assigned a score of 4 (indicating dyskinesis), whereas 6 (akinesis with scar) defaults to 3 (akinesis) for the purposes of calculating the wall motion score index. The report shows scores for pre-exercise and postexercise wall motion and demonstrates apical akinesis after treadmill exercise. The global wall motion score index is normal before exercise (1.0) and worsens (1.3) after exercise.
posttreadmill imaging within seconds. This requires a degree of patient agility, as well as considerable operator skill. As noted, because time delays may allow the decay of heart rate, and induced wall motion abnormalities may normalize quickly after exercise, any undue delays during the critical period between cessation of exercise and start of imaging may have the effect of lowering the overall accuracy of the test, particularly in areas of collateral flow, single-vessel disease, and moderately stenotic (50–70%) lesions.[51] Conversely, at higher workloads, greater degrees of ischemia
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 20
occasionally ensue, and prolonged myocardial stunning may take place, with wall motion abnormalities persisting for several minutes after exercise.[1] [52] [53] [54] Because of the technical difficulties involved in the acquisition of images within a limited time frame, a learning curve exists for the experienced technician-sonographer of about 50 stress echocardiographic studies. This learning curve is clearly required prior to smooth performance and acquisition of images within the required 90second time period. Bicycle Exercise Echocardiographic Protocol Two bicycle protocols are currently in use: upright and supine. Although these are more widely used in Europe in conjunction with echocardiography, both have enjoyed an increase in popularity in the United States. In each of the bicycle protocols, imaging is performed at baseline, at peak exercise, and immediately after exercise. The upright bicycle protocol is shown in Table 13-2 . In the upright bicycle protocol, two-dimensional baseline images are recorded at rest in the parasternal long- and short-axis and apical four-chamber and two-chamber views in the left lateral decubitus position. The patient moves onto the upright bicycle, and the apical views are repeated at rest in the upright position. Using the same view facilitates comparison between rest and peak images. Exercise then begins with the patient pedaling, sometimes following a brief warm-up period, and proceeds in increments of 25 to 50 watts in 2- or 3minute stages. As the patient exercises, apical views can be recorded on tape throughout the examination. End points for bicycle exercise are the same as for treadmill imaging: predetermined age-related peak heart rate, the development of significant symptoms, or significant electrocardiographic changes. Just prior to stopping at peak exercise, the apical four-chamber and two-chamber views are recorded, and the patient resumes the left lateral decubitus position on an examining bed or table for immediate postexercise parasternal views, as well as repeat apical views. Digital TABLE 13-2 -- Upright Bicycle Protocol 1. Complete baseline study performed in left lateral decubitus position 2. Parasternal long-axis, short-axis, four-chamber, and two-chamber views recorded on tape and digitized 3. Patient assumes upright position on bicycle for apical rest views 4. Pedaling begins at 60 rpm, 25 watts, and increases by 25 watts every 2
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 20
to 3 minutes 5. Peak exercise views obtained at the end of each stage 6. At completion of exercise, patient reassumes left lateral decubitus position for immediate postexercise and recovery images
282
images are captured at the end of each stage, with each subsequent stage overriding the previous peak image. In this way, if a patient suddenly stops exercising early in any stage, the last image captured will be the peak exercise image. The exercise protocol itself may vary. One popular protocol is to have the patient begin pedaling at 60 rpm at 25 watts and to increase the resistance by 25 watts every 2 minutes while the patient continues to pedal at 60 rpm. Maximal exercise is then terminated at 250 watts or at 85% of the predicted maximal heart rate. Because many patients undergoing testing are older, their ability to pedal is highly variable, and tremendous latitude may be necessary in selecting workloads. Smaller increases in resistance are usually necessary in elderly individuals and patients unaccustomed to bicycle exercise. Also, variations in the imaging protocol are sometimes needed because of technical difficulty in obtaining apical views during exercise. One alternative to apical imaging is subcostal views.[44] This approach eliminates superimposition of the air-filled lung and may be more feasible for patients with chest wall deformities or chronic obstructive lung disease. Compared with the upright bicycle, supine bicycle exercise has a simpler protocol in that all imaging takes place with the patient on the bicycle, eliminating the need for an additional imaging table or bed for parasternal views. After acquisition of all four baseline views (parasternal long-axis, parasternal short-axis, four-chamber, and two-chamber) as described earlier, the patient begins pedaling in the supine position while apical views are obtained at each stage and recorded on videotape during exercise in similar fashion to the upright bicycle. At peak exercise, the images are digitized for viewing in quad-screen side-by-side format as previously described. In our laboratory, the four quadrants consist of pre-exercise images on the left and peak exercise images on the right, a display similar to that used in posttreadmill exercise. In addition, recovery images are
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 20
recorded on videotape after the heart rate and blood pressure have returned to pre-exercise levels. Comparison of Stress Modalities As mentioned earlier, all forms of exercise have their relative advantages and disadvantages, and selection of stress modality should be based on individual patient characteristics, the patient's ability to exercise, and the information one wishes to obtain (Table 13-3) . With treadmill exercise, imaging at peak stress is technically difficult and, although a few reports have explored the feasibility of peak treadmill imaging, posttreadmill imaging TABLE 13-3 -- Comparison of Peak Bicycle and Posttreadmill Imaging Peak Bicycle Imaging Improved sensitivity Slightly decreased specificity Lower cardiovascular workloads More leg fatigue
Posttreadmill Imaging Less cumbersome protocol Improved image quality Higher cardiovascular workloads More familiar, better tolerated by most patients
remains the most widely applied technique. Advantages of treadmill exercise include patient familiarity as well as a lack of need for additional equipment, since most laboratories and hospitals are already equipped with a treadmill for routine exercise testing. In many cases, a digital frame grabber to digitize images at baseline and at peak exercise for side-by-side comparison is the only additional equipment required. One of the main disadvantages of the treadmill is that it relies on capture of images in "allor-none" fashion after exercise, providing a post-stress "snapshot" of the heart. Unlike with bicycle stress, which provides multiple views of the heart at various intermediate stages of stress, the exact stage of onset of ischemia cannot be detected with treadmill protocols. An advantage of bicycle exercise, therefore, is the ability to image at various levels of stress, allowing the time to onset of ischemia to be recorded and compared between serial studies, possibly providing additional prognostic information. Peak images, rather than posttreadmill images, also have the theoretical advantage of higher sensitivity, since wall motion abnormalities may revert to normal within seconds after exercise.[52] This advantage of bicycle exercise over treadmill exercise may be offset,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 20
however, by the fact that in the United States patients are usually more accepting of treadmill exercise and less limited by leg fatigue, since walking is a familiar activity. Exercising in the supine position requires that the weight of the legs be supported against gravity and may lead to earlier stopping because of leg discomfort and fatigue. In addition, supine exercise may lead to submaximal heart rate response and lower cardiovascular workloads, with the development of angina at a lower pressure rate product. [55] [56] Thus, maximal workloads attained in the supine position may actually be lower than those obtained in the upright position on the bicycle or the treadmill. Upright bicycle exercise theoretically produces higher workloads at equivalent levels of blood pressure and heart rate but provides a more cumbersome protocol. The major potential advantage of imaging performed at peak exercise rather than postexercise is that transient ischemia and its ensuing wall motion abnormalities may resolve quickly and be missed with posttreadmill testing, leading to a lower sensitivity for the detection of coronary artery disease. As noted, however, the higher workload achieved with treadmill exercise may offset the potential benefit of imaging during peak exercise. One study has directly compared the sensitivity and specificity of peak versus postexercise imaging using the same exercise modality in the same patients. Presti et al[52] used upright bicycle echocardiography to evaluate 104 consecutive patients referred for known or suspected coronary disease. Of these, 96 patients had echocardiograms suitable for wall motion analysis at rest, during peak bicycle exercise, and immediately after bicycle exercise (feasibility, 92%). The overall sensitivity of postexercise imaging for the detection of coronary disease was 70%, compared with 100% for peak exercise images. When the parasternal views were added, three additional patients demonstrated postexercise abnormalities. When the coronary anatomy of patients with false-negative studies was examined, it was found that the development of wall motion abnormalities 283
at only peak exercise was more likely to occur in patients with stenotic areas supplied by collateral flow. There have been few direct comparisons of different types of exercise in conjunction with echocardiography in the same patient population. Three studies have compared treadmill testing and bicycle exercise testing in conjunction with echocardiography. The earliest of these, by Applegate et
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 20
al,[57] evaluated 21 patients after myocardial infarction using low-level, symptom-limited stress testing, with similar workloads achieved in each form of exercise. This study suggested that the delay in posttreadmill imaging did not significantly affect the sensitivity for detection of exerciseinduced ischemia in this postmyocardial infarction population. Two studies have compared posttreadmill with peak supine bicycle exercise in a stable population with coronary disease.[58] [59] One of these studies noted an advantage for peak stress bicycle imaging in the identification of coronary disease. Dagianti et al,[58] examining a small series of 10 male patients with coronary disease, noted 100% sensitivity for supine bicycle with only 60% for posttreadmill imaging. In a larger series of 74 patients, Badruddin et al [59] noted a sensitivity of 83% and specificity of 70% for supine bicycle and 75% and 90% for treadmill echocardiography, a difference that did not reach statistical significance. Taken together, these data may indicate a relatively small advantage in the detection of ischemia for selected patients who are able to perform bicycle exercise, particularly patients with singlevessel disease or collateral flow. Interpretation of Stress Echocardiograms Echocardiograms can be interpreted qualitatively, with a descriptive summary of the myocardial response to exercise, or quantitatively, providing a numeric description of wall motion (see Fig. 13-4) . For clinical purposes, a descriptive summary of wall motion response often provides enough information to aid the referring clinician in patient management. Regardless of the chosen scheme, a normal echocardiogram is one in which there is normal resting wall motion and a hyperdynamic response to exercise with symmetric wall thickening and equal excursion in all segments. The development of a wall motion abnormality either at peak exercise or immediately after exercise is sensitive and specific for ischemia and is evidence of underlying coronary disease. Using a qualitative approach, wall motion is often described as "normal," "ischemic," or "fixed," depending on the response to exercise (Table 13-4) . Ischemic segments are labeled as such if they appear normal or mildly hypokinetic at rest and worsen with exercise, whereas fixed areas are akinetic at rest and are unchanged or become dyskinetic with exercise, implying scarred myocardium due to transmural infarction. In most studies, new wall motion abnormalities may be detected when a coronary stenosis of greater than 50% exists, with increased likelihood for detection with stenoses of greater than 70%. Accordingly, using a visual estimate of 50%
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 20
as a cut-off point would result in a lower sensitivity for detection of coronary disease than using 70%. Hypokinetic TABLE 13-4 -- Categorization of Exercise Echocardiographic Wall Motion Responses Wall Motion at Rest Normal Normal Abnormal excursion (thinned) Abnormal excursion (preserved thickness)
Wall Motion During Exercise Normal Abnormal: Worsening Fixed: No significant change New or worsening abnormality
Category Normal Ischemic Scar: Transmural infarction Hibernating
areas with full-thickness myocardium that worsen after exercise are likely to represent areas that are both viable and ischemic, the resting abnormality representing stunned or hibernating myocardium. Using qualitative terms such as these, one generally reports a description of wall motion and a diagnosis such as "inferior hypokinesis following exercise, consistent with inferior ischemia." Occasionally, lack of hyperdynamic response or frank hypokinesis will be noted in myocardium that is not supplied by a significant stenosis. This situation has been noted in aortic valve disease, in extreme elevations in blood pressure, and, in our experience, occasionally with occult myopathy. The most widely accepted quantitative approach is the wall motion score index recommended by the American Society of Echocardiography, which uses a scoring system from 1 to 4 depending on the degree of abnormality. [60] A grade of 1 is assigned to normal segments and 2 through 4 for hypokinetic, akinetic, or dyskinetic segments, respectively. Some laboratories also grade the lack of development of a hyperdynamic response as abnormal, assigning a grade of 0 to hyperkinetic regions. Grading lack of hyperdynamic response as abnormal results in higher sensitivity for the detection of coronary disease but may result in poorer specificity.[61] Using this wall motion scoring system, one then assigns a number to each of 16 segments and divides by the total number of segments for the calculation of a global wall motion score index (Fig. 13-5) . Alternatively, individual coronary territories can be assigned a "regional" wall motion score index. Either a global score or a regional score can then be used to assess responses to specific medical therapy or to cardiac
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 15 di 20
interventions over time. With use of a regional wall motion score index, it is possible to predict the specific location of a coronary artery stenosis from the area of the wall motion abnormality and thus to provide important prognostic information regarding the nature of the underlying disease. A schematic representation of coronary blood supply in each segment using a 16-segment model is shown in Figure 13-5 . With this scheme, accurate distinction of anterior from posterior circulation is possible. Within the posterior circulation, separating left circumflex from right coronary artery territory is much more difficult because of individual variation in anatomy. In most situations, however, important diagnostic information is provided simply by separating the left anterior descending territory from the posterior circulation. Obviously, segments with normal resting ventricular 284
Figure 13-5 Diagram depicting how coronary artery territory is incorporated into the 16-segment model. Although some overlap is commonly seen, separation of anterior from posterior circulation is 80% to 90% accurate. Individual variation in coronary anatomy usually precludes accurate separation of right coronary from left circumflex territories. (Modified from Segar DS, Brown SE, Sawada SG, et al: J Am Coll Cardiol 1992;19:1199, with permission from the American College of Cardiology.)
function that augment during exercise indicate a patent coronary blood supply. Figure 13-3 depicts a normal hyperdynamic ventricular response after exercise, implying normal coronary arteries. As noted, normal resting ventricular function in a segment or segments that worsen during exercise indicates the presence of significant underlying coronary disease and ischemia. Figure 13-6 depicts an ischemic response following treadmill exercise. In this case, a 52-year-old woman with new-onset exertional discomfort demonstrated normal resting systolic function. After 6 minutes of exercise, a wall motion abnormality developed in the anterior septum, signifying left anterior descending artery ischemia (as seen in the postexercise systolic image). This patient was found to have a 75% stenosis of the left anterior descending artery. Abnormal resting ventricular function that worsens during or after exercise is sometimes a confusing picture and may represent one of a number of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 16 di 20
potential clinical possibilities. Areas of full-thickness myocardium that are hypokinetic at rest may represent areas of chronic repetitive stunning, chronically ischemic (hibernating) myocardium, or previous nontransmural myocardial infarction supplied by a critically stenosed artery. Regardless of the cause of resting hypokinesis, worsening after exercise is likely to represent an ischemic response. Segments that are bright, thin, and akinetic at rest and become dyskinetic after exercise are more likely to represent transmural infarction without significant ischemia. The patient depicted in Figure 13-7 is a 54-year-old man with chest discomfort who was able to exercise for 8 minutes on a Bruce protocol. The wall motion is normal at rest. Following treadmill exercise, an abnormality developed in the basal inferior segments (seen in the lower right-hand frame), and at catheterization the patient was found to have an 80% stenosis of the right coronary artery. One sees a break point in the myocardium (arrow) at the junction of the right coronary and left anterior descending artery territories, signifying left anterior descending artery patency juxtaposed against a stenosed right coronary artery. The patient in Figure 13-8 demonstrates abnormalities in the same myocardial segments of the basal inferior wall; however, in this case the myocardium is thinned and aneurysmal at rest, consistent with prior transmural infarction of the interior wall. Worsening 285
Figure 13-6 Exercise echocardiogram demonstrating anterior ischemia with dyskinesis of the anterior septum in parasternal long-axis view after exercise. The response suggests hemodynamically significant disease in the left anterior descending artery. DIAS, diastolic; POST, postexercise; PRE, pre-exercise (baseline); SYS, systolic.
in this case from akinesis to dyskinesis represents a fixed abnormality consistent with scar rather than ischemia. At catheterization, a total occlusion of the right coronary artery was found. As noted, myocardium that is hypokinetic at rest may represent stunning, hibernating, or a mixture of normal and infarcted myocardium. Accurately sorting out and interpreting the responses to exercise in these complex cases often requires integration of angiographic data derived from cardiac catheterization as well as the clinical
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 17 di 20
Figure 13-7 Exercise echocardiogram demonstrating inferior ischemia. Diastolic (DIAS) and systolic (SYS) frames at baseline (PRE) and after exercise (POST) demonstrate normal resting wall motion with outward systolic motion (dyskinesis) of basal inferior segments after exercise. This patient had a critical stenosis of the right coronary artery. (See text for further explanation.)
history. Some of these complex responses and the possible relationship to the underlying clinical significance are shown in Table 13-5 . Advantages and Disadvantages of Exercise Echocardiography When compared with routine treadmill exercise, there are a number of advantages to performing exercise echocardiography, 286
Figure 13-8 Exercise echocardiogram demonstrating prior inferior wall myocardial infarction due to right coronary artery occlusion. The basal inferior segments are echogenic and akinetic at rest, suggesting scar. After exercise, the scarred region becomes dyskinetic, indicating "fixed" disease. DIAS, diastolic; POST, postexercise; PRE, pre-exercise (baseline); SYS, systolic.
as shown in Table 13-6 . Although routine treadmill testing remains the most prominent form of diagnostic testing for patients with known or suspected coronary disease in the United States, its sensitivity and specificity are limited in many patients in whom the ST segment response is unreliable or uninterpretable.[62] [63] [64] [65] Patients who have a high likelihood of false-positive, false-negative, or nondiagnostic electrocardiographic responses demonstrate improved accuracy for the detection of coronary TABLE 13-5 -- Clinical Interpretation of Complex Responses * Interpretation Normal Excursion Wall thickness CAD/No MI Excursion
At Rest
After Exercise
Normal Normal
Hyperdynamic
Normal
Hypokinetic, akinetic, or dyskinetic
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Wall thickness Normal CAD/Nontransmural MI Excursion Hypokinetic or akinetic
Pagina 18 di 20
Augmented, hypokinetic, akinetic, or dyskinetic (dependent on infarct artery patency)
Wall thickness Partial or full CAD/Transmural MI Excursion Akinetic Akinetic or dyskinetic Wall thickness Thinned CAD/Hibernating/Stunned Excursion Hypokinetic or Incompletely investigated May akinetic augment with mild exercise Wall thickness Partial or full CAD, coronary artery disease; MI, myocardial infarction. * Response depends on extent of residual stenosis.
disease with the addition of echocardiography.[6] These include women; patients with left bundle branch block; patients taking digoxin; patients with prior nontransmural myocardial infarction, Wolff-Parkinson-White syndrome, or mitral valve prolapse; patients with hyperventilation ST segment changes; and a large group of patients with nonspecific ST-T wave changes at rest. Echocardiographic imaging in conjunction with exercise stress testing has been shown to increase the diagnostic accuracy in patients such as these with resting electrocardiographic abnormalities, which some experts believe make up as much as 30% to 40% of patients presenting for exercise testing. A major advantage of exercise echocardiography is its versatility in the diagnosis of structural heart disease not related to coronary disease. Echocardiography has the ability to diagnose any and all forms of structural heart disease as a cause of angina or other cardiac symptoms. Thus, if exertional symptoms are due to valvular heart disease, pulmonary hypertension, diastolic dysfunction, or pericardial disease, the diagnosis can be made with exercise echocardiography. Figure 13-9 provides an example in which shortness of breath was suspected to be an anginal equivalent in a
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 19 di 20
patient with multiple risk factors TABLE 13-6 -- Relative Advantages and Disadvantages of Stress Echocardiography Advantages Versatile (evaluates all structural abnormalities) Portable
Disadvantages Analyzed qualitatively Requires additional trained personnel Requires additional equipment Adds time to routine treadmill test
Minimal space requirements Increases sensitivity and specificity Evaluates wall thickening Low risk
287
Figure 13-9 Parasternal long-axis and short-axis views depicting a normal hyperdynamic response to exercise in a patient with severe left ventricular hypertrophy and resting repolarization changes on electrocardiogram. Systolic frames (SYS) are compared before (PRE) and after (POST) treadmill exercise. DIAS, diastolic.
for coronary disease. In this case, a patient with chronic renal disease, hypertension, and obvious left ventricular hypertrophy demonstrated baseline secondary ST segment changes and a positive electrocardiographic response to exercise, while the echocardiographic response clearly demonstrates a normal hyperdynamic response, with increased endocardial excursion and symmetric wall thickening in all segments. In some cases, the baseline study may provide clues to diagnosis and reveal a contraindication to stress testing, such as the finding of critical aortic stenosis or significant pericardial effusion. In our laboratory, a previously unsuspected but important cardiac diagnosis occasionally emerges from the resting echocardiographic study and engenders a reason to cancel the stress test. In this respect, exercise echocardiography provides a measure of safety unattainable by routine electrocardiographic monitoring or radionuclide imaging. Another advantage is that echocardiographic equipment can be transported to any area equipped with a treadmill or stationary bicycle, such
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 20 di 20
as the hospital emergency department. Echocardiography is also the only bedside imaging technique that evaluates systolic wall thickening. There are some potential disadvantages to the addition of echocardiography to routine treadmill testing. First, it requires additional personnel and training. In most laboratories this requires two technicians, but one experienced technician may perform both the imaging and monitoring tasks, provided there is a physician in the immediate area (see Equipment, Methodology, and Personnel and also Fig. 13-2) . Another potential disadvantage to exercise echocardiography is the need for additional equipment, which in some cases is only a device for frame-grabbing digital images, since many outpatient clinics and hospitals are already equipped with echocardiographic instrumentation and a treadmill. Echocardiographic imaging also adds approximately 30 minutes to the time of the routine treadmill test. Also, although the results are reproducible, to date no highly quantifiable methods exist to evaluate wall motion or systolic thickening in the clinical setting.[64] Until an easily quantifiable system for wall motion evaluation exists, interpretation of stress echocardiograms remains largely qualitative. Given the overall accuracy reported, this has not proved a major disadvantage. Obviously, these potential disadvantages are a trade-off for increased diagnostic accuracy compared with treadmill testing. It is important to remember, however, that as with any form of imaging in conjunction with exercise testing, the sensitivity of stress echocardiography will be poor in patients who cannot reach an adequate level of cardiovascular stress. For those patients, pharmacologic stress echocardiography is a desirable alternative (see Chapter 14) . Patients who should undergo pharmacologic stress because of high rates of false-negative results due to inadequate exercise levels include patients with peripheral vascular disease, patients with orthopedic problems, elderly persons, and individuals who are deconditioned. For these and other unselected patient populations, the reported accuracy of dobutamine echocardiography for the diagnosis of known or suspected coronary disease has been excellent, around 85% to 95%. This is well within the range of competing nuclear imaging techniques.[7] [8]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/113.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 22
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Clinical Applications of Exercise Echocardiography Accuracy in the Identification of Coronary Artery Disease Several studies have been published reflecting the overall accuracy of exercise echocardiography in the diagnosis 288
of coronary artery disease.[44] [51] [52] [55] , [61] [66] [67] [68] [69] [70] [71] [72] [73] [74] [75] [76] [77] [78] [79] In the first of these studies, published by Wann et al[1] [6] in 1979 at Indiana University, patients were studied with a 30-degree sector scanner during peak supine bicycle exercise. Despite primitive equipment, the overall sensitivity was 87% and the specificity was 100%, not unlike the sensitivities and specificities currently reported with state-of-the-art imaging equipment and digital acquisition techniques. The accuracy of various exercise stress echocardiographic techniques has been verified in numerous laboratories. Many early studies reported sensitivities in the range of 60% to 90%, whereas more recently, particularly with the advent of digital imaging methodologies, sensitivities have more consistently been in the higher end of this range. Table 13-7 compares the sensitivities and specificities of some of the larger reported studies. Many of the early studies focused on the ability of stress echocardiography to detect changes in global function, sometimes using radionuclide ventriculography as the gold standard.[69] [80] [81] [82] These studies demonstrated an increase in indices of global systolic function (such as ejection fraction or pressure/volume ratio) for normal subjects and depressed indices for patients with previous myocardial infarction. One of the first large studies demonstrating increased sensitivity and specificity with the addition of echocardiography to routine treadmill testing using arteriography as the gold standard was that of Armstrong et al,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 22
[6]
in which 95 patients underwent both posttreadmill exercise and cardiac catherization. Of the 59 patients in whom there was no evidence of prior infarction, 44 were found to have coronary disease at subsequent coronary arteriography. Exercise echocardiography was abnormal in 35 of these 44 patients, for an overall sensitivity of 80%. In contrast, the exercise electrocardiogram demonstrated ischemia in only 19 of these patients (sensitivity, 43%) and was normal in 13 patients (30%) and nondiagnostic in 12 patients (27%), demonstrating the ability of exercise echocardiography to identify coronary disease in patients with an ambiguous or inaccurate treadmill response. Conversely, exercise echocardiographic results were normal in 13 of 15 patients without coronary disease, for a specificity of 87%. In 36 patients with prior infarction, 35 had rest or exercise-induced wall motion abnormalities, or both, for a sensitivity of 97%. TABLE 13-7 -- Accuracy of Exercise Echocardiography
Study Limacher et al[69] Armstrong et al[6] Armstrong et al[32] Ryan et al
Patients, n Modality 73 Treadmill
Single Stenosis Vessel * Grade, Sensitivity, Disease, Sp % % % 50 91 64
95 Treadmill
50
88
—
123 Treadmill
50
88
81
64 Treadmill
50
78
76
[72]
Sawada et al[124] Crouse et al[61] Marwick et al[76] Hecht et al
57 Treadmill/upright bicycle 228 Treadmill
50
86
88
50
97
92
150 Treadmill
50
84
77
180 Supine bicycle
50
93
84
[50]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Ryan et al
Pagina 3 di 22
309 Upright bicycle
50
91
86
150 Treadmill
50
91
—
80 Treadmill
50
89
76
[51]
Roger et al [67]
Marangelli et al[143]
* Definition of significant coronary artery disease.
Because the inclusion of patients with left ventricular wall motion abnormalities at rest falsely elevates the sensitivity of echocardiography for the detection of coronary disease (a fact that is also true for radionuclide imaging), a later study from the same laboratory examined the use of exercise echocardiography in 64 patients with normal wall motion at rest.[72] Twenty-four patients had no angiographic evidence of coronary artery disease, and all 24 had a negative exercise echocardiogram, for a specificity of 100%. Of 40 patients with coronary disease, 31 had a positive exercise echocardiogram (sensitivity, 78%). In a more current era, Marwick et al[76] reported an overall sensitivity of 84% and a specificity of 86% in 150 patients who underwent exercise echocardiography and coronary arteriography, with slightly higher sensitivity and slightly lower specificity when patients with nondiagnostic test results were excluded. Nondiagnostic test results stemming from an inability to reach a target heart rate in the setting of beta blocker use is a common problem in a clinical setting and appears to affect sensitivity more than specificity.[83] Sensitivities and specificities may vary between studies depending on the prevalence of disease in the population under study, the definition of significant disease, and the criteria used for a positive test. Clinical factors such as age, cardiac risk factors, and prior history of angina, all of which affect pretest likelihood of coronary disease, influence sensitivity and specificity, with sensitivities tending to be higher in populations with a higher pretest likelihood of disease. Sensitivity and specificity are also affected by the criteria used to define a positive test. Crouse et al[61] reported a high sensitivity of 97% and a relatively low specificity of 64% in a series of 228 patients undergoing treadmill echocardiography as a screening test. In this study, a normal test was defined as the presence of hypercontractility in addition to the absence of inducible wall motion abnormalities, adding to
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 22
the sensitivity but detracting from the specificity of the results. Probably the biggest influence on specificity is that of posttest referral bias, which alludes to the fact that as a test becomes more accepted by the medical community, more patients with positive tests, and fewer of those with normal studies, are referred for coronary arteriography. Since only a small proportion of those with normal studies are given the opportunity to verify their test results, this 289
tends to lower specificity dramatically. Concomitantly, sensitivity is raised, since more patients with positive tests are referred for angiography. This point was illustrated in a study of 244 men and 96 women by Roger et al[80] that noted that bias in referral patterns for angiography may have a dramatic effect in lowering specificity. Accuracy of all types of stress testing is equally affected by biased referral for cardiac catherization or "verification bias," with lower sensitivities and higher specificities likely compared with those reported. To overcome posttest referral bias, in some studies a "normalcy" rate is calculated for subgroups thought to be at low risk for coronary artery disease within a population. This can then be used as a reasonable substitute for specificity. Thus, through clinical characteristics and demographic factors, subgroups likely to have a less than 5% pretest likelihood of significant coronary disease are identified, and these patients are then assumed to be free of significant coronary artery disease. The number of patients with a normal stress test within this group are identified. Normalcy is then calculated as the number of patients with a normal exercise test divided by the number of those at very low clinical risk for the disease. A few studies have reported normalcy rates when the catheterized population was skewed in the direction of patients with coronary disease. In a published series of 180 patients studied with supine bicycle and coronary arteriography, Hecht[50] reported an overall sensitivity of 93%, a specificity of 86%, and an overall accuracy of 92%. The normalcy rate for 42 patients who had a less than 5% pretest likelihood of significant coronary disease was 100%. Similarly, Marwick et al[36] have reported a normalcy rate of over 90% in 29 of 150 patients with normal results on an exercise echocardiogram and low pretest likelihood. Another influence on the accuracy of exercise echocardiography is the definition of significant disease, which is in part determined by the physiologic significance of a stenosis. This was illustrated in a study by
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 22
Sheikh et al[33] who found that stenoses of greater than 75% diameter were more frequently associated with wall motion abnormalities during exercise echocardiography than stenoses of less than 25%. Stenoses in the range of 50% appeared to be evenly divided between positive and negative results when assessed by visual estimates of stenosis. Using quantitative angiographic methods, however, the authors were able to further stratify the ventricular responses into two subgroups. Those patients with wall motion abnormalities were associated with luminal stenoses of greater than 50%, whereas normal wall motion was associated with stenoses of less than 50%, suggesting that visual estimates may be unable to determine which stenoses in the moderate range are significant. This and other studies highlight the limitations inherent in using a diameter stenosis as visually determined to define significant disease.[73] [85] [86] Factors such as proximal location, presence of collateral flows, and plaque morphology have been shown to influence coronary flow, particularly in the setting of submaximal effort. Some recent studies have used intravascular ultrasonography rather than arteriography to define significant stenoses, and these studies further emphasize the limitations of "luminography" as a gold standard. An arteriogram being a two-dimensional representation of a three-dimensional artery may under- or overrepresent the degree of stenosis depending on the views selected. Factors such as bends or kinks in the vessel may cause some areas to falsely appear stenotic, whereas plaque irregularity may lead to underassessment of the functional significance of stenoses.[87] In clinical practice, functional assessment of a stenosis in relation to results of stress testing should always be undertaken along with integration of clinical factors with angiographic results. Currently, the overall accuracy of exercise echocardiography is in the range of 80% to 90%. A recent meta-analysis of 2637 patients reported in 24 articles noted an overall sensitivity of 85% and specificity of 77% for exercise echocardiography, examining only studies in a current era that reported results for all patients such that the calculation of sensitivity and specificity was possible with numbers of patients reported, along with coronary angiography used as the reference test.[88] Taken together, these studies illustrate the ability of exercise echocardiography to identify patients with angiographically significant disease and to provide an assessment of the physiologic significance of stenoses comparable to other stress imaging tests. Exercise Echocardiography After Angioplasty
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 22
Because of its ability to target separate coronary artery distributions, exercise echocardiography may be an ideal tool for surveillance of patients after coronary interventions. Studies suggest that echocardiographic imaging can assess the initial outcome of angioplasty, atherectomy, and stenting, as well as provide valuable information regarding the presence of restenosis.[89] [90] [91] [92] [93] [94] [95] [96] [97] [98] [99] [100] One of the early studies demonstrating the ability of exercise echocardiography to provide a functional assessment in patients before and after angioplasty was that of Broderick et al[91] in which 36 patients were studied before and after coronary angioplasty. Thirty-one patients demonstrated ischemia with either an abnormal exercise test result (exercise-induced ST depression or angina) or an abnormal exercise echocardiogram (exercise-induced wall motion abnormalities). After successful angioplasty, 17 patients continued to demonstrate exerciseinduced ischemia by either electrocardiographic or echocardiographic criteria. Although 12 of these 17 patients continued to demonstrate exercise-induced wall motion abnormalities, most were improved compared with the studies prior to angioplasty. Exercise duration, workload, and METS (metabolic equivalents) increased after angioplasty, suggesting that some of the wall motion abnormalities after angioplasty might be explained by a greater ischemic burden. Since follow-up studies were performed 2 weeks or more after angioplasty and no patient had undergone repeat angiography, it is possible that some of these failures to demonstrate improvement represented early restenosis. A few other studies from high-volume laboratories have reported success in the use of exercise echocardiography to evaluate patients before and after angioplasty. Labovitz et al[94] noted new exercise-induced echocardiographic abnormalities in 12 of 17 patients prior to angioplasty and 290
in none of these patients after angioplasty. When 1 mm of ST segment depression was added to the criteria for ischemia, 16 of 17 patients demonstrated ischemia prior to angioplasty. Thus, using a combination of electrocardiographic and echocardiographic criteria increased the sensitivity for the detection of coronary artery disease from 71% to 94%. Both of these studies demonstrate improved accuracy with the addition of two-dimensional echocardiography to exercise testing in postprocedure
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 22
assessment of the functional significance of coronary artery disease. In the study by Labovitz et al,[94] exercise ejection fraction also improved after angioplasty and was similar to that noted in age-matched normal control subjects. In our laboratory, if inducible wall motion abnormalities remain or recur after angioplasty at similar workloads as those noted prior to angioplasty, coronary arteriography is generally undertaken if the patient has symptoms or if a large coronary territory is in jeopardy. Figure 13-10 demonstrates the resting and posttreadmill systolic frames from a patient who had undergone angioplasty of the left anterior descending artery 3 months previously and who had developed atypical chest pain. Postexercise systolic images of the apical four-chamber view demonstrate an apical wall motion abnormality. At catheterization, the patient was found to have restenosis with a 90% luminal narrowing of the middle left anterior descending artery. Limited data have been published on the use of exercise echocardiography in the detection of restenosis, but these have been encouraging in suggesting a role for exercise echocardiography in the long-term follow-up of patients undergoing angioplasty. Hecht et al[93] used supine bicycle echocardiography to examine 80 patients an average of 6 months after angioplasty to determine whether this Figure 13-10 Systolic frames of apical four-chamber (A) and twochamber (B) views at rest (PRE) and after exercise (POST) demonstrating an apical abnormality in a patient with prior left anterior descending artery angioplasty. This patient was found to have restenosis at the site of previous percutaneous transluminal coronary angioplasty.
technique could detect restenosis. The overall sensitivity of supine bicycle exercise echocardiography was 87%, compared with 55% for electrocardiographic sensitivity. The specificity was 95% for exercise echocardiography, compared with 79% for exercise electrocardiography. Sensitivity was highest (91%) for the left anterior descending artery. The sensitivity of supine bicycle echocardiography for the detection of restenosis was surprisingly high, despite a low percentage of patients achieving 85% of predicted maximal heart rate, suggesting that the restenosis lesion was hemodynamically significant at a low cardiovascular workload. The fact that supine bicycle stress echocardiography utilizes peak exercise imaging may account for the higher sensitivities reported with this technique. In another study, Dagianti et al[101] demonstrated the
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 22
usefulness of supine bicycle echocardiography shortly after balloon angioplasty to detect clinical restenosis at 6 months. Sixteen of 18 patients who subsequently went on to develop symptomatic restenosis documented angiographically had an early positive bicycle echocardiogram, suggesting that visual estimates may overestimate the early procedural success and that substrate for the restenosis lesion may begin early. Supine bicycle echocardiography was not successful in predicting asymptomatic angiographic restenosis, again pointing out that when performed in an asymptomatic population, percent diameter stenosis as determined by arteriography may not be an accurate reflection of the adequacy of flow. Chest pain is more closely linked to coronary flow reserve than is absolute stenosis diameter.[102] [103] Thus, patients who are asymptomatic despite angiographic evidence of restenosis may be better treated conservatively, particularly if they are able to engage in exercise without limitation. Few studies have compared radionuclide methods with 291
stress echocardiography for assessment of angioplasty results. One study compared single photon emission computed tomography (SPECT) thallium and exercise echocardiography before and after angioplasty. Fioretti et al[92] compared the results of exercise echocardiography with thallium-201 SPECT before and after angioplasty in 23 patients. Prior to angioplasty, the concordance rate between the two techniques was 78%. Nineteen patients were restudied with both techniques within 4 weeks after angioplasty. Echocardiography and SPECT were concordant in 17 of these 19 patients (89%), suggesting that exercise echocardiography is a feasible alternative to thallium-201 SPECT techniques for assessing patients who are undergoing angioplasty. These studies suggest that exercise echocardiography may have a role in serial assessment of patients undergoing coronary revascularization, both in the initial detection of functionally significant stenoses and in the assessment of the results of interventions. In contrast to these, an earlier study by Aboul-Enein et al[104] reported a sensitivity of only 67% using posttreadmill echocardiography to detect restenosis 6 months after successful coronary angioplasty. Looking at maximal predicted heart rate, pressure rate product, and exercise duration, the authors could find no significant differences between the 32 patients in whom exercise echocardiography correctly predicted restenosis and 16
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 22
patients with false-negative results, suggesting a lack of functional significance of the angiographically determined stenosis. Differences in populations between this study and others with better sensitivity for restenosis detection may explain the lower sensitivity noted by these authors. Whereas the patients in the latter study underwent exercise echocardiography and coronary arteriography 6 months after angioplasty as part of a study protocol, regardless of symptoms, the patients in the study by Hecht et al,[93] for example, were evaluated because of recurrent chest pain, suggesting a higher pretest probability. Also, 38 of 48 (80%) of those found to have angiographic restenosis in the study by Aboul-Enein et al[104] had single-vessel disease, which is less likely to produce a positive test result. More recently, Mertes et al[95] examined the role of bicycle stress echocardiography utilizing peak exercise imaging in 86 patients approximately 6 months after nonsurgical revascularization, including angioplasty, stenting, and atherectomy. The overall sensitivity for peak bicycle stress echocardiography in the detection of significant coronary artery disease was 83%, and the specificity was 85%. This is compared with a sensitivity of 42% for stress electrocardiographic detection of significant coronary artery stenoses. In this study, stress echocardiography was also found to be useful for detecting progression of previously existing coronary stenoses that had not undergone revascularization. Interestingly, all patients with false-negative results in this study had failed to achieve the target heart rate at peak exercise. To circumvent the problem of suboptimal exercise, Hoffman et al [105] used transesophageal pacing echocardiography in the detection of restenosis in 60 patients approximately 5 months after successful angioplasty. The sensitivity of transesophageal pacing echocardiography for the detection of restenosis or progression of coronary disease in nondilated vessels was 84% and compared favorably with the 86% sensitivity for technetium-99m sestamibi-SPECT imaging. The sensitivity of electrocardiography in this study was 50%. Many centers have gone to the use of pharmacologic stress echocardiography after revascularization in patients who are unable to perform maximal exercise. Preliminary data suggest that dobutamine stress echocardiography is able to identify patients with significant coronary stenosis prior to angioplasty and to demonstrate improvement in wall motion abnormalities after successful angioplasty (see Chapter 14) .
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 22
Exercise Echocardiography After Coronary Artery Bypass Grafting Although exercise echocardiography has become an accepted modality as a screening test in the initial evaluation of patients with suspected coronary artery disease, limited data exist regarding the use of exercise echocardiography to predict graft patency after coronary artery bypass grafting. Treadmill exercise testing has been the accepted modality for evaluation of patients after bypass surgery, but the high prevalence of resting electrocardiographic abnormalities in this group introduces a high rate of nondiagnostic electrocardiographic responses. For this reason, thallium SPECT imaging was recognized early on as a valuable adjunct in sorting out the nondiagnostic electrocardiographic responses in such patients.[106] It seems logical that if exercise echocardiography is able to accurately detect ischemic segments in territories deprived of blood supply via native vessels, segments supplied by stenotic grafts would be similarly detected. Although few in number, published studies using exercise echocardiography to detect graft patency have been extremely encouraging; these are summarized in Table 13-8 .[107] [108] [109] Sawada et al[107] used upright bicycle exercise echocardiography to assess bypass graft patency in 41 patients at a mean of 6 years after coronary artery bypass surgery. The presence of inducible ischemia was correlated with vessel stenoses, including obstructed bypass grafts, obstructed native vessels without prior revascularization, and diseased native vessels distal to anastomotic sites. In the 35 patients with graft stenosis, exercise echocardiography demonstrated ischemia in 33 patients, a sensitivity of 94%. Exercise echocardiography also correctly identified five of six patients without significant disease, with a specificity of 83%. Through the use of segmental wall motion analysis, accurate identification of the location of significant stenoses (i.e., anterior vs. posterior circulation) was possible. The sensitivity for detection of TABLE 13-8 -- Accuracy of Exercise Echocardiography After Coronary Artery Bypass Grafting (CABG) Study Sawada et al[107] Crouse et al[108] Kafka et al[109]
Patients, n 41 125 182
Years After CABG 6 7 3.6
Sensitivity, % 94 98 79
Specificity, % 83 92 82
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 22
292
compromised arterial supply in the left anterior descending distribution was 89%, and in the posterior circulation it was 88%. Crouse et al[108] studied 125 patients a mean of 7 years after coronary artery bypass grafting and reported a sensitivity of 98% and a specificity of 92% for the detection of graft or native vessel stenoses of 50% or greater reduction in luminal diameter. More recently, Kafka et al[109] reported that exercise echocardiography was able to successfully detect both singlevessel disease and multivessel disease, with a sensitivity of 77% and 96%, respectively, in a population of 182 patients undergoing symptom-limited treadmill exercise, electrocardiography, and exercise echocardiography for routine follow-up. Patients in this study had undergone revascularization with coronary artery bypass grafting 3½ years previously. Despite a lower prevalence of disease in this series when compared to the series of Sawada et al[107] and Crouse et al, [108] the overall sensitivity and positive predictive value were high (85%) when compared with exercise electrocardiography, which had a positive predictive value of only 62%. The negative predictive value for the corresponding techniques was 81% and 52% for exercise electrocardiography and echocardiography, respectively. In summary, the results of exercise echocardiography compare favorably to results of studies using thallium SPECT in the detection of ischemia in the region of coronary artery bypass grafts. Echocardiography performed in conjunction with exercise electrocardiography has a high feasibility rate— greater than 90% in these reported series—and provides superior sensitivity and specificity than exercise electrocardiography alone. These studies illustrate the ability of exercise echocardiography to identify graft as well as native disease stenosis in a population in whom interpretation of electrocardiographic response is less than optimal. Exercise Echocardiography After Acute Myocardial Infarction Following successful reperfusion for acute myocardial infarction, accurate prognostic assessment is critical in directing expensive and limited invasive resources to those patients who will receive the greatest benefit. Two important determinants of prognosis are left ventricular systolic function and the severity of underlying coronary artery disease. Medical centers performing primary angioplasty may use the results of cardiac catheterization to provide risk assessment, but most clinicians have traditionally performed noninvasive testing to predict prognosis and guide
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 12 di 22
future therapy. The practitioner has a choice of tests with which to accomplish this assessment. In the past, two tests have frequently been called upon to provide assessment of systolic function and ischemia: radionuclide ventriculography or echocardiography to determine systolic function and submaximal exercise testing for the assessment of ischemic burden. More recently, stress echocardiography has been used to provide data about both left ventricular function and the presence of residual ischemia to assess future risk of cardiac events. Future ischemic events appear to involve increasingly complex interactions between an ischemic milieu and inflammation, but stress echocardiography is a relatively inexpensive test that has been shown to correctly stratify patients into highand low-risk subgroups. Submaximal exercise testing can be safely performed after myocardial infarction and has been shown to provide useful prognostic information with regard to subsequent cardiac events.[110] [111] Treadmill testing, however, while able to identify some patients who are at high risk for subsequent cardiac events, has a sensitivity of only 50% to 70% for the prediction of subsequent coronary events.[112] [113] Thallium scintigraphy has been shown to improve the sensitivity for prediction of cardiac events after myocardial infarction.[114] More recently, two-dimensional echocardiography after low-level treadmill exercise has been shown to provide useful information for the purposes of risk stratification and prediction of subsequent cardiac events.[57] [115] [116] Most of the studies examining exercise echocardiography for postmyocardial infarction assessment were performed before the widespread use of reperfusion therapy and included as events the "soft" events of revascularization. Nonetheless, these studies demonstrate the ability of exercise echocardiography to identify a high-risk group, particularly when combined with clinical risk assessment. Jaarsma et al[115] studied a group of 43 patients with exercise echocardiography within 3 weeks of acute myocardial infarction. All patients were noted to have resting wall motion abnormalities. Images obtained immediately after exercise demonstrated new wall motion abnormalities, remote from the site of myocardial infarction, in 18 patients, 17 of whom were shown to have multivessel coronary artery disease. This is compared with only 5 of 25 patients without remote wall motion abnormality who were found at catheterization to have multivessel disease. The development of a new wall motion abnormality, remote from the site of myocardial infarction, predicted multivessel coronary disease with a
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 13 di 22
sensitivity of 77% and a specificity of 95%. It also predicted a high-risk group for reinfarction or recurrent angina within 12 weeks, demonstrating the ability of exercise echocardiography to predict a higher risk group for cardiac events based on the identification of patients with multivessel disease. Transient remote ischemia during the first several hours of acute myocardial infarction has been attributed to a supply-demand imbalance in areas perfused by a critically stenosed vessel in noninfarcted segments of myocardium. Because remote ischemia signifies multivessel disease, these patients would presumably be at high risk for the development of subsequent events. Ryan et al[116] examined the predictive value of either remote or adjacent asynergy in 40 patients shortly after myocardial infarction using posttreadmill exercise echocardiography and found it to have an excellent predictive value for subsequent cardiac events. In a 6- to 10-month follow-up period, cardiac events occurred in 20 patients, 16 of whom had a positive exercise echocardiogram (80% sensitivity). A negative exercise echocardiogram was predictive of a good clinical outcome without subsequent cardiac events in 19 of 20 patients (specificity, 95%). In this group of postmyocardial infarction patients, treadmill characteristics were unable to identify high- and low-risk groups. Likewise, Applegate 293
et al[57] found that neither electrocardiographic nor clinical characteristics could identify a high-risk group in another study of 21 patients who underwent symptom-limited treadmill exercise shortly after acute myocardial infarction. In this study, multivariate logistic regression analysis was performed on several clinical, treadmill, and electrocardiographic characteristics. Wall motion abnormalities immediately after exercise and echocardiographically determined ejection fraction had the highest predictive value (P < .001) for the prediction of future cardiac events. In patients treated with thrombolysis, the ability to exclude significant multivessel disease may help to avoid cardiac catheterization and to direct expensive resources and higher risk technologies to those patients who are at higher risk for poor outcome. Quintana et al[117] examined exercise echocardiography within a week after myocardial infarction in 70 patients, about half of whom had received thrombolytic therapy. Exercise
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 14 di 22
echocardiography correctly identified a high-risk group for cardiac events within 2 weeks after myocardial infarction. Twenty-two percent (6 of 27) of those with a positive exercise echocardiogram, versus only 5% (2 of 43) of those with negative studies, suffered an early cardiac event. At 4-year follow-up, the cumulative event-free survival rate was significantly better in patients with a negative exercise echocardiography. While the electrocardiographic response also identified patients in whom events were more likely to occur, exercise electrocardiography was unable to identify a low-risk group. These studies demonstrate the usefulness of twodimensional exercise echocardiography in helping to stratify patients into high- and low-risk groups after myocardial infarction and to predict a highrisk group for subsequent cardiac events on the basis of ischemia. An area of current active clinical investigation is the application of pharmacologic stress echocardiography to identify stunned and hibernating myocardium after myocardial infarction. The goal of these techniques is to determine potentially viable segments of myocardium that would be expected to recover function without revascularization after myocardial infarction, as opposed to those that are more likely to benefit from revascularization. Dobutamine echocardiography, discussed in Chapter 14 , has shown promise in the area of identification of stunned segments in the immediate post-infarction period and has been widely utilized for this purpose. Recruitment of myocardial segments with low-dose dobutamine shortly after acute myocardial infarction identifies segments that are likely to recover function without further intervention.[118] [119] Subsequent deterioration of some segments with higher doses of dobutamine (the socalled "biphasic" response) signify segments that may improve only after revascularization is performed. In theory, a low level of exercise could potentially be used to identify viable myocardium in analogous fashion to low levels of dobutamine infusion. A study by Hoffer et al[120] has investigated the utility of low-level bicycle exercise shortly after myocardial infarction to identify reversible dysfunction through augmentation of stunned segments. These authors noted improvement with low-level bicycle exercise in some akinetic segments within the infarction zone of patients with recent myocardial infarction, similar to the augmented response seen in viable segments with low-dose dobutamine infusion. Segments that improved with exercise were more likely to recover function at follow-up, signifying reversible dysfunction. Since multiple graded levels of exercise were not tested, it is unknown whether some segments that improve with low levels of exercise would demonstrate a biphasic response as well, with higher cardiac workloads. Whether
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 15 di 22
echocardiographic monitoring during multiple graded levels of exercise could detect ischemic segments suitable for revascularization has not been investigated. Exercise Echocardiography in Women Despite the fact that cardiovascular disease is the number one killer of women in the United States, accounting for approximately 500,000 deaths annually, most studies involving noninvasive techniques to identify patients with coronary artery disease focused exclusively on men, until relatively recently. Because of a variety of social, economic, and medical beliefs, women were excluded from populations with coronary disease under study. Even in the current era, there are surprisingly few studies examining diagnostic and prognostic implications of noninvasive testing of women (Table 13-9) . One reason for the paucity of published data in the noninvasive assessment of coronary disease in women is the fact that stress testing is believed to be less accurate in women. Indeed, early studies of electrocardiographic stress testing in women usually displayed poorer sensitivity and specificity for the identification of significant coronary disease.[63] [121] [122] In retrospect, however, the majority of these studies were performed in women who, according to Bayesian theory, were of low pretest likelihood with lower disease prevalence than their male cohorts, a factor that adversely affects specificity. The low disease prevalence in populations under study contributed to the belief that women are less likely to suffer from coronary disease and less likely to need referral for invasive testing. As discussed previously, verification bias, or the tendency to avoid sending those with negative test results for cardiac catheterization, is also a major contributor to lower test specificity in women. Contributing to the lower sensitivity of stress testing in women is the fact that, in many early studies, women appear to have lower exercise capacity, achieving submaximal levels of cardiovascular stress more often, thereby rendering it less likely that ischemia would be provoked. In addition, hormonal and autonomic factors, inappropriate catecholamine release, syndrome X, and the presence of more comorbid diseases at the time TABLE 13-9 -- Studies Examining the Accuracy of Exercise Echocardiography in Women Study Sawada et al[124] Williams et al[125] Marwick et al[126]
Year 1989 1994 1995
Patients, n Sensitivity, % Specificity, % 57 86 86 70 88 84 161 80 81
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Roger et al[84]
Pagina 16 di 22
1997
96
79
37
294
of diagnosis, may further contribute to test inaccuracies in women. In an effort to increase the overall accuracy of stress testing in women, some practitioners have advocated the use of imaging techniques as an initial test. Recent studies have focused on the addition of echocardiographic imaging as a means to increase the accuracy of stress testing as an initial diagnostic test in women.[123] Recent studies have examined the echocardiographic responses to treadmill or bicycle exercise in women also undergoing diagnostic catheterization. [84] [124] [125] [126] Sawada et al[124] examined the diagnostic value of exercise echocardiography in 57 women with chest pain syndromes using coronary arteriography as the gold standard. Sensitivity and specificity for echocardiographic detection of coronary stenosis of 50% or greater were both 86%. Exercise echocardiography was particularly useful in sorting out patients with atypical chest pain with coronary disease (sensitivity, 84%) from those with a nondiagnostic exercise electrocardiogram who were free of coronary disease (specificity, 82%). Similarly, Williams et al[125] compared the accuracy of the exercise echocardiogram to the accuracy of 12-lead electrocardiography performed during maximal treadmill exercise in 70 women with a 53% pretest probability for coronary disease. Defining significant coronary disease as greater than 50% stenosis, exercise echocardiography had a sensitivity of 88% for the detection of coronary artery disease, compared with 57% for electrocardiographic analysis using ST depression of greater than 0.1 mV. The specificity of exercise echocardiography was 84%, compared with 51% for echocardiographic analysis. In both of these studies, the accuracy of exercise echocardiography significantly exceeded that of exercise electrocardiography and paralleled larger studies of predominantly male patients. [6] [51] , [61] [76] Marwick et al[126] investigated the use of exercise echocardiography in the detection of coronary disease in women and found it to have an overall accuracy of 81%, compared with overall accuracy of 64% for exercise electrocardiography. In addition, these authors examined the cost of exercise echocardiography and noted that it compared favorably with
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 17 di 22
several potential diagnostic strategies in the work-up of cardiac symptoms in women. These authors sought to identify a diagnostic strategy that would balance the cost of diagnostic testing (defined as local Medicare reimbursement) with the lowest number of false-negative results and the fewest inappropriate referrals for cardiac catheterization. Compared with electrocardiography or echocardiography as an initial test (with and without Bayesian analysis) or angiography alone as the only diagnostic work-up, exercise echocardiography provided the best overall accuracy at the least cost. Data continue to accumulate that exercise echocardiography, because of preserved accuracy in patients with low to intermediate pretest likelihood of disease and because Medicare reimbursement rates are roughly half of those for radionuclide methods, may be the initial stress test of choice for women. The ultimate test of any noninvasive strategy may not be its ability to detect disease but its ability to predict future events. Recent studies have examined the ability of exercise echocardiography to predict prognosis in patients with known or suspected coronary artery disease.[127] [128] [129] Some of these studies focus on outcomes of women or include women as a major proportion of patients. One of the first of these studies was that of Sawada et al,[127] which encompassed 71 women among 148 patients who were followed for 28 ± 8 months after having a normal exercise echocardiogram. Cardiac events occurred in 2.8% (2 women) at 28 months without evidence of abnormality on exercise echocardiogram, demonstrating the ability of exercise echocardiography to identify a low-risk group for future events. Likewise, McCully et al[128] reported, in a large group of patients of whom about half were women, an excellent event-free survival rate for patients with normal treadmill echocardiograms who achieved an adequate level of cardiovascular stress (>5 METs for women). Another study examining prognosis in women reported that exercise-induced ischemia predicted cardiac events. In a multivariate analysis, Heupler et al[129] demonstrated incremental predictive value for exercise echocardiography in addition to clinical factors and exercise electrocardiography. Many of these studies have been performed in academic centers where referral of higher risk patients may falsely elevate the sensitivity of diagnostic testing and its ability to prognosticate. Exercise echocardiography has also been shown to correctly stratify women as to risk in a community setting. In a study of 1188 women with known or suspected coronary disease who underwent treadmill exercise echocardiography, the degree of ischemic wall motion abnormality was an
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 18 di 22
important factor in identifying a very high risk group.[130] Patients with resting wall motion abnormalities in addition to exercise-induced ischemic abnormalities had the highest rate of cardiac death and myocardial infarction. These studies highlight the ability of echocardiography to risk-stratify patients into high-, intermediate-, and low-risk subsets based on echocardiographic response to exercise and to select patients who will most benefit from further invasive procedures. Further studies will need to be performed. Exercise Echocardiography in the Determination of Prognosis The acceptance of stress echocardiography as a diagnostic tool able to guide decision making for medical and interventional procedures has allowed for follow-up of patients with coronary disease. Published event rates for patients with myocardial infarction undergoing exercise echocardiography were discussed earlier and demonstrate a higher rate of cardiac events in patients with significant degrees of inducible ischemia after infarction. As with acute myocardial infarction, the major determinants of prognosis in chronic coronary artery disease are overall left ventricular function and the presence and severity of ischemia. Echocardiography, in its ability to evaluate both of these factors, makes an ideal tool for the determination of prognosis. Event rates for patients with chronic coronary disease with normal or abnormal test results have been examined with regard to "hard" cardiac events such as myocardial infarction and cardiac death as well as "soft" cardiac events such as revascularization. These findings demonstrate a more benign prognosis for patients with normal exercise echocardiograms, with higher event rates noted for those with inducible ischemia (Table 13-10) 295
TABLE 13-10 -- Exercise Echocardiography for Prognostic Assessment of Patients with Known or Suspected Coronary Artery Disease
Study Sawada et al[127]
Patients, n Follow-up, mos 148 28
Event Rates * Abnormal Normal SE SE — 1.7/.85 *
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Marwick et al[132] Krivokapich et al
Pagina 19 di 22
463 360
44 12
9/6.5 34/9
7/2 9/2
1325
23
—
2.5/<1
[131]
McCully et al[128]
* Percentage of events at 12 months, total/spontaneous. SE, stress echocardiography.
Two studies have noted low event rates of less than 1% per year in patients with normal resting function and no exercise-induced wall motion abnormality.[127] [128] Importantly, in both of these studies, a normal study finding is defined as one that is normal both at rest and with exercise. In some cases, higher event rates have been noted for patients with negative test results, and often these higher event rates were reported in studies that allowed patients with resting wall motion abnormalities to be included within the "negative" group. Krivokapich et al,[131] defining a negative test result as lack of ischemia with exercise, noted a higher event rate of 9% in patients with a negative exercise echocardiogram. In this study, soft events such as revascularization were also included as events, obviously having had an adverse affect on total event rate. When only myocardial infarction is examined, the event rate dropped to only 2%. Likewise, Marwick et al[132] noted in a group of 463 patients an event rate of 7% for patients with a negative exercise echocardiogram but when 15 of 20 patients with revascularization as the only event were excluded, the event rate was reduced to less than 2% per year for spontaneous events. These studies demonstrate that exercise echocardiography in patients undergoing stress testing for known or suspected coronary disease is able to effectively stratify patients as to future risk and to guide therapy for patients at higher risk. The presence of electrocardiographic ST depression appears to add prognostic information to the value of the echocardiographic response. For example, in the study of Marwick et al[132] , the rate of events including revascularization was highest in patients with both echocardiographic and electrocardiographic evidence of ischemia (event rate, 45%), with a lower event rate of 38% in patients without exercise-induced electrocardiographic changes. Likewise, Krivokapich et al[131] noted highest event rates for patients with both electrocardiographic and echocardiographic evidence of ischemia. In patients without echocardiographic evidence of ischemia,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 20 di 22
however, event rates were still higher in patients with a positive exercise electrocardiogram compared with a negative electrocardiogram. In both of these studies, although echocardiographic wall motion response appears to provide the greatest prognostic information, the electrocardiographic response appears to add prognostic value. Dobutamine echocardiography, discussed elsewhere, has provided the largest group of data for prognostication in patients referred for known or suspected coronary disease.[133] [134] In particular, dobutamine echocardiography appears to be able to accurately stratify risk in patients scheduled for vascular surgery, with published data encompassing more than 1500 patients.[135] Together, exercise and pharmacologic stress echocardiography is quickly gaining momentum as a test that can accurately and effectively stratify patient risk and guide therapeutic decisions. Cost-Effectiveness Issues The rising tide of health care costs, along with recent government budget cuts for reimbursement for many inpatient procedures, mandates that physicians be aware of the relative costs of procedures they order or perform on their patients. The cost of any procedure can be examined from a variety of viewpoints, including the cost to the patient—that is, insurance or Medicare reimbursement—the actual cost to the hospital or physician performing the test, and the cost of further diagnostic testing that the test result initiates. Cost-effectiveness examines cost versus healthcare outcome, usually expressed as a unit of effect on health care, such as survival or quality-assisted life-years. This is not meant to be a comprehensive discussion of cost analysis but a simple comparison of stress echocardiography with other testing strategies that provide similar information at similar risk to the patient. Several authors have addressed the issue of cost-effectiveness of stress testing as an initial strategy as compared with proceeding directly to invasive tests, and many of these assessments highlight the importance of determining pretest likelihood of disease prior to testing.[136] [137] [138] [139] If a high degree of likelihood exists that a patient has coronary disease, (greater than 75%), then the best initial strategy is likely to be proceeding directly to angiography, as suggested by Bayes' theorem. On the other hand, in case of very low pretest likelihood (i.e., less than 20%), perhaps no further testing is recommended. For patients with intermediate pretest likelihood of disease, the best initial strategy has been shown to be noninvasive testing
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 21 di 22
followed by catheterization in patients with high likelihood of significant coronary disease based on results of noninvasive testing. In contrast, Shaw et al[136] examined the use of radionuclide imaging as an initial strategy in women and found that noninvasive testing was approximately $1000 less over a 2.5-year period as compared with proceeding directly to catheterization for patients with intermediate pretest likelihood of disease. Similarly, Marwick et al[126] examined multiple different strategies involving stress electrocardiography or echocardiography versus catheterization as an initial strategy, noting that exercise echocardiography led to the least number of false results, providing the greatest sensitivity and specificity for detection of coronary disease. False-positive test results were presumed 296
to lead to inappropriate angiography. Thus, although exercise electrocardiography was a less costly test from the standpoint of reimbursement, it was assumed to lead to a higher number of inappropriate catheterizations. Medicare fees and volumes for various stress testing techniques, which were published in 1996, compared professional and technical fees as well as relative value units (RVUs), which provide an estimate of relative cost.[140] Within the published guidelines of the American College of Cardiology and the American Heart Association for exercise testing, while treadmill testing alone was noted to be least costly (3.30 RVUs), performing this test in all cases would not necessarily result in lower cost of patient care, since test inaccuracies can be expected to lead to further unnecessary testing. Imaging adds considerably to the cost of reimbursement (5.3 times that of treadmill), as does echocardiography (2.3 times higher). However, as discussed previously, given the improved accuracy of exercise echocardiography, its relatively lower expense as an imaging modality when compared with radionuclide technology makes it an attractive alternative. In comparison with radionuclide techniques, echocardiography is likely to be reimbursed at roughly half the relative cost, based on Medicare reimbursement. In this light, few studies have examined nuclear techniques with echocardiography as a screening test. Garber et al[137] compared an initial strategy of arteriography with one of five noninvasive strategies, initially including echocardiography, nuclear techniques with SPECT, positron emission tomography, or treadmill electrocardiography. There were no significant differences in life expectancy based on the initial diagnostic test. The total cost of a strategy
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 22 di 22
that used echocardiography was less than one that began with radionuclide based on a cost-effectiveness ratio. Because of improved sensitivity compared with treadmill testing, exercise echocardiography resulted in better outcome. Thus, echocardiography was a highly cost-effective alternative to treadmill or radionuclide imaging. Kuntz et al[138] examined the cost-effectiveness of noninvasive strategies with exercise treadmill electrocardiography, exercise echocardiography, or SPECT nuclear imaging versus arteriography in the initial diagnosis of coronary disease. These authors found that either exercise electrocardiography or exercise echocardiography resulted in "reasonable" cost-effectiveness ratios for patients with mild to moderate risk for coronary artery disease. Proceeding directly to arteriography was costeffective for patients with high pretest probability of coronary artery disease. Further studies of both cost and outcome will need to be performed in randomized fashion with longer term follow-up to determine whether exercise echocardiography will continue to assume a greater role in settings where HMO-driven decisions mandate the most information at the least cost.
MD Consult L.L.C. http://www.mdconsult.com /das/book/view/26070721/1031/114.html/top Bookmark URL:
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Exercise Echocardiography Compared with Other Imaging Modalities A number of studies have compared exercise echocardiography with the more well established radionuclide techniques for the diagnosis of coronary disease. An early study compared two-dimensional echocardiography with radionuclide angiography during left lateral decubitus bicycle ergometry.[44] This study noted a higher sensitivity, 91%, for radionuclide angiography versus 76% for exercise echocardiography using a bicycle protocol. The problem with this and many subsequent studies is that such comparisons take place in centers where one or the other of the techniques being compared is more widely utilized, and different levels of expertise exist for the competing technologies. An exception to this is the large study of 292 patients reported by Quinones et al[141] that analyzed all patients with both exercise echocardiography and SPECT thallium for the diagnosis of coronary disease. Sensitivity for single-vessel disease was quite low with both techniques (58% for echocardiography and 61% for thallium SPECT), and both techniques correctly identified three-vessel disease with a 94% sensitivity. Specificity was similar in both groups (88% for echocardiography and 81% for thallium SPECT). In a comparison of exercise echocardiography with technetium-99m MIBI-SPECT, Pozzoli et al[142] found a good correlation between perfusion and wall motion in 103 consecutive patients, with concordance in 84% of segments overall. Concordance was especially high (91%) in patients with previous myocardial infarction. These studies, while limited, demonstrate the ability of both techniques to detect patients with significant disease, providing similar clinical information about the functional significance of underlying coronary disease. The advantage of echocardiography lies in its ability to provide additional information about left ventricular function and underlying valvular disease without adding significantly to the time of the echocardiographic study. The accuracy of exercise echocardiography has also been compared to that
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
of echocardiography with different forms of cardiovascular stress. Beleslin et al[40] compared exercise, dobutamine, and dipyridamole echocardiography in 136 consecutive patients with a high prevalence of coronary artery disease. The sensitivity of exercise echocardiography was 88%, compared with 82% for dobutamine echocardiography and 74% for dipyridamole echocardiography. Specificity for exercise, dobutamine, and dipyridamole echocardiography was 82%, 77%, and 94%, respectively. All three tests were noted to have acceptable diagnostic value, with a higher diagnostic accuracy for stress echocardiography in patients with singlevessel disease. Similarly, Marangelli et al[143] compared exercise, dipyridamole, and transesophageal atrial pacing in conjunction with echocardiography in 104 consecutive patients with normal resting wall motion who underwent coronary arteriography. The sensitivities for exercise, transesophageal atrial pacing, and dipyridamole were 89%, 83%, and 43%, respectively, suggesting that exercise and atrial pacing have similar sensitivities and may exceed the sensitivity of pharmacologic stress with vasodilators. In comparison with nonexercise forms of cardiovascular stress, the additional information gleaned from analysis of the hemodynamic response to exercise proves to be an invaluable adjunct in the clinical assessment of patients. If the patient is able to exercise, the additional clinical value gained in analyzing the physiologic exercise data adds 297
incrementally to the information learned from wall motion analysis alone.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/115.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 1
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Summary Exercise echocardiography is an accurate technique for initial diagnosis of coronary disease and can provide prognostic information in many subgroups with known disease. Over the past decade, its acceptance by the medical community has grown and current applications have expanded to include diagnosis and prognosis in a wide range of patients, including women, for whom accuracy and cost appear better than other comparable techniques. Current clinical applications of exercise echocardiography include diagnosis of suspected coronary disease, guiding percutaneous intervention, surveillance of patients following coronary bypass surgery, and prediction of prognosis in chronic coronary disease as well as acute myocardial infarction. Accuracy of exercise echocardiography is now considered to be at parity with other noninvasive imaging techniques with a cost roughly half that of competing nuclear techniques. Its lower cost makes exercise echocardiography an attractive alternative as an initial diagnostic test and in follow-up of patients with coronary disease.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/116.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 5
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
301
Chapter 14 - Stress Echocardiography with Nonexercise Techniques Principles, Protocols, Interpretation, and Clinical Applications Thomas H. Marwick MD, PhD
302
TABLE 14-1 -- Indications for Nonexercise Stressors Unable to Exercise Inability to exercise maximally Diagnosis of coronary artery disease, decision making
Able to Exercise Specific indications Coronary spasm
Myocardial viability Risk stratification Developing indications Situations preventing exercise Onset of ischemia Angiography laboratory, operating room New technologies (TDI, CK, contrast) CK, color kinesis; TDI, tissue Doppler imaging.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 5
Background Indications for Nonexercise Stress Testing The performance of a maximal level of exercise is a critical determinant of the sensitivity of all stress modalities for the detection of coronary artery disease. Unfortunately, many patients—fully 30% to 40% at some tertiary centers (Fig. 14-1) (Figure Not Available) —either cannot exercise at all or cannot exercise maximally,[1] but these patients may still need to undergo stress testing for diagnostic, decision making, or prognostic purposes. The most common causes of limited exercise capacity are vascular disease (either peripheral or cerebrovascular) and orthopedic problems. Other situations warranting nonexercise stress testing include severe cardiopulmonary disease and general debility, especially among the elderly, in whom pharmacologic testing with both dobutamine and vasodilators has been shown to be well tolerated and reliable.[2] [3] [4] [5] Although the inability of a patient to exercise maximally constitutes the main indication for the use of nonexercise stressors, such stressors are less commonly indicated in other situations (Table 14-1) . The most important of these situations include circumstances in which the use of a pharmacologic agent may offer diagnostic dimensions that are not available from exercise stress, for example, the diagnosis of coronary spasm using ergonovine stress testing.[6] [7] A similar scenario involves patients early or late after myocardial infarction, after which left ventricular dysfunction may not be permanent. The diagnostic challenge in this situation is that whereas stunned myocardium improves spontaneously, the revascularization of hibernating Figure 14-1 (Figure Not Available) Proportion of patients undergoing exercise testing who are unable to exercise maximally. (From Marwick T: Acta Clin Belg 1992;47:1– 51.)
myocardium has implications for functional capacity and prognosis. As discussed later in the chapter, echocardiography can be used with dobutamine[8] or dipyridamole[9] [10] stress, or both,[11] for the identification of viable myocardium. Pharmacologic agents are more appropriate than exercise for stress testing in some environments, such as the cardiac catheterization laboratory or operating rooms. Finally, nonexercise methods have been used in
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 5
preference to exercise echocardiography even in patients who are able to exercise because of their relative technical ease. The incremental nature of these stressors means that the time-course of ischemia can be identified; these data are not available using posttreadmill stress and are more difficult to obtain with bicycle exercise testing. Although the decision to use a nonexercise stress may not be justifiable with routine echocardiographic imaging at present, the facilitation of adjunctive techniques discussed subsequently—such as tissue Doppler, color kinesis, and contrast echocardiography (which may be less feasible during exercise than nonexercise stress)—could in the future justify the use of nonexercise techniques in patients who are able to exercise. Choice and Mechanism of Action of Nonexercise Stressors There are two general groups of nonexercise stress agents: those that induce ischemia by increasing myocardial work and oxygen consumption (exercise-simulating agents), and those that induce ischemia by influencing coronary perfusion and therefore myocardial oxygen supply (vasoactive agents). The latter include the coronary vasodilators dipyridamole and adenosine, which cause ischemia by provoking coronary steal, and ergonovine, which can be used to provoke coronary spasm. In addition to these stressors, nonpharmacologic approaches including hand-grip and the cold pressor test[12] [13] have been used. Hand-grip testing is often combined with dobutamine-atropine testing,[14] but the cold pressor test has not been widely adopted clinically because of limited efficacy and patient discomfort. Exercise-Simulating Agents
The exercise simulators include dobutamine and other sympathomimetic agents, pacing stress, and atropine 303
(usually used as an adjunct to the other approaches), all of which increase cardiac work and myocardial oxygen requirement. Thus, the induction of ischemia and regional dysfunction reflects the inability of the diseased coronary circulation to respond to this increased oxygen demand, a process that parallels the response to exercise. However, processes additional to classic "demand" ischemia may be active, and sympathomimetic agents may place an additional stress on the heart through effects on cardiac metabolism—an "oxygen-wasting" effect. In a group of patients with
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 5
ischemic responses to both dobutamine and exercise, ischemia appeared at a significantly lower rate-pressure product during dobutamine than during exercise stress, consistent with the presence of a factor additive to that of cardiac work suggested experimentally.[15] [16] [17] Another contributor to this process might include concurrent "supply" ischemia due to reduction of coronary flow; certainly, sympathomimetic agents cause a dose-dependent reduction of subendocardial perfusion and maldistribution of coronary flow, in the face of mild coronary stenoses.[18] The latter component, together with regional flow heterogeneity based on tachycardia-induced coronary vasodilation, [19] is responsible for perfusion defects detected at myocardial perfusion imaging. Because increased cardiac workload and oxygen demand is the usual mechanism underlying ischemia in most ambulatory situations, the exercise-simulating agents are often considered to be a more physiologic means of stressing the heart, although "demand" ischemia may be combined with reduction in coronary supply due to vasospasm or coronary steal. Vasoactive Agents
The use of dipyridamole in combination with myocardial perfusion imaging is based on the induction of maximal coronary vasodilation in all territories. Flow heterogeneities (and therefore apparent perfusion defects) develop if a coronary stenosis limits the regional hyperemic response.[20] Of note, this process does not involve the provocation of ischemia in a functional or metabolic sense. In contrast, the development of regional wall motion abnormalities at stress echocardiography necessitates the induction of ischemia. The chief mechanism of vasodilator-induced ischemia is coronary steal,[20] which may be either "vertical" or "horizontal" through the left ventricular wall. The best known mechanism is horizontal steal, in which blood flows to nonstenosed from stenosed territory, owing to reduced collateral flow into the stenosed territory because of depressurization of vessels supplying the collaterals due to increased runoff. Vertical steal also occurs because of vasodilator-induced depressurization of the microcirculation, causing subendocardial vessels to collapse under the greater extravascular pressure in this region and "stealing" flow to the subepicardium from the subendocardium. Other mechanisms of vasodilator-induced ischemia, unrelated to coronary steal, include reduced coronary supply because of coronary spasm (which is the major effect of ergotamine), systemic hypotension, or collapse of the stenosis. Under conditions of maximal coronary hyperemia, driving pressure is the main determinant of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 5
myocardial perfusion because vasodilator reserve is exhausted. Hence, systemic hypotension may accentuate hypoperfusion due to coronary steal. Stenosis "collapse" may be provoked if profound microcirculatory vasodilation causes a reduction of lateral pressure induced by increased flow. Finally, myocardial oxygen demand may be increased in response to increased cardiac workload because of increased sympathetic activity secondary to angina. Agents Used to Identify Myocardial Viability
In the presence of dysfunctional but viable myocardium, regional function is enhanced by the inotropic effect of low-dose dobutamine, although this appears to require both recruitable perfusion and an increment in metabolism.[21] The mechanism of this is ill-defined but most likely pertains to enhanced calcium cycling. Viable myocardium supplied by a patent infarct-related vessel (generally corresponding to stunned myocardium) demonstrates a sustained improvement during the infusion, which then reverses after the test. Viable tissue supplied by a stenosed infarct-related artery (which may involve stunned or chronically ischemic— "hibernating"—tissue) is characterized by an initial improvement, occurring at low doses (<20 µg/kg/minute), or low heart rates, or both, followed by deterioration of regional function as the chronotropic effect becomes more prominent and myocardial work increases.[8] If the region is supplied by a critically stenosed artery, however, it may be possible for the territory to become ischemic before there is a noticeable enhancement of contractility. Moreover, the ability of the myocardium to thicken is determined by the amount of infarcted tissue within the segment.[22] Myocardial viability may also be inferred from the contractile response to dipyridamole. The mechanism of this is also putative but probably relates to myocardial congestion with interstitial fluid due to vasodilation. A socalled mini-Starling effect may be caused by this congestive process, producing additional tension on the myofibrils.[23]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/118.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 11
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Principles of Nonexercise Stress Techniques Pharmacology and Physiopathology of Nonexercise Stress Techniques Exercise-Simulating Agents
The exercise-simulating agents include dobutamine, dopamine, epinephrine, and isoproterenol. Of these, dobutamine has become the most commonly administered exercise-simulating agent, and the majority of published data on pharmacologic stress echocardiography have involved this agent. Arbutamine, a dobutamine isomer, was developed in the last decade but showed no substantial clinical merits compared with its parent compound, and distribution of the agent has been discontinued.[24] [25] Dopamine 304
stimulates alpha receptors and, if it extravasates, may cause localized limb ischemia due to vasoconstriction. Dopamine may also be a less effective precipitant of myocardial ischemia than is dobutamine.[26] Although other sympathomimetic agents have been used for stress testing,[27] epinephrine and isoproterenol are probably the more arrhythmogenic. This side effect is dose dependent, but its avoidance by conservative dosing may compromise the sensitivity of the test by limiting the amount of stress on the heart. Dobutamine is predominantly a beta-1 agonist, and normal areas become hyperkinetic in response to its inotropic effect. Myocardial segments supplied by a stenosed coronary artery may become akinetic or dyskinetic but more commonly are unable to augment their thickening and excursion, and the contrast between this response and the hyperkinetic function of normal segments facilitates the detection of zones with abnormal function. Vasodilation and chronotropy appear at higher doses, [26] usually at the 20 µg/kg/minute level of the routine dobutamine stress protocols, reflecting
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 11
the stimulation of other receptors to a lesser degree. This chronotropic response appears to be the most important factor in terms of precipitating ischemia; most dobutamine stress protocols cause a mean heart rate increment of 40 to 50 beats per minute and mean peak heart rates of 110 to 120 beats per minute.[28] [29] [30] [31] [32] [33] [34] However, reflex bradycardia may occur in response to hypertension. The vasodilator effects of dobutamine may cause blood pressure to fall at peak doses, although blood pressure normally rises in response to the inotropic effect of the drug. Increases in myocardial oxygen demand due to increased cardiac work, as well as a weak vasodilator effect, lead to the development of coronary hyperemia in territories supplied by normal coronary arteries. Although this response is probably less than that induced by coronary vasodilators, the coronary hyperemic response to dobutamine stress permits its combination with perfusion scintigraphy.[34] [35] [36] [37] The detection of myocardial perfusion defects in the presence of coronary disease may be augmented by partial volume effects due to thinning of the ischemic wall. Vasoactive Agents
Most of the experience with pharmacologic stress echocardiography using vasoactive agents has been obtained with the coronary vasodilators dipyridamole and adenosine. The coronary vasodilators differ with respect to the onset and duration of their effects. Dipyridamole increases endogenous adenosine levels by reducing cellular reuptake and metabolism, and thereby acts indirectly.[20] This indirect mechanism causes some delay between the administration of this agent and the timing of peak vasodilation, the half-life of this effect being 6 hours. The indirect action of dipyridamole may account for interindividual variations in the magnitude of its effects. Adenosine acts directly on the vasculature, its vasodilator efficacy being equivalent to that of papaverine.[38] The potency and speed of onset of adenosine cause its side effects to be more intense but also more short-lived than those of dipyridamole. An increasing amount of literature describes the combination of ergonovine with echocardiography. This agent has a direct effect on the vessel; responsiveness to acetylcholine may be related to loss of nitric oxide production at the site of disease. Exercise Simulation Using Pacing Stress
Several nonpharmacologic approaches have been used for stress echocardiography, including "physiologic" stresses such as the cold pressor
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 11
test, which are poorly tolerated. Pacing is an alternative means of increasing cardiac work without resorting to pharmacologic techniques. Pacing-induced tachycardia increases myocardial oxygen consumption and thereby causes myocardial ischemia in the setting of significant coronary stenoses.[39] [40] The reduction of subendocardial perfusion with pacing[40] may also contribute to the development of ischemia. Ventricular pacing is not favored, as it causes both abnormal regional contractility and abnormal perfusion, so that pacing stress techniques generally involve atrial stimulation, either transvenously or via the esophagus (only the latter having gained acceptance as a routine stress modality). Of these, direct atrial pacing has been used for other stress imaging tests, but it is invasive and therefore has not achieved acceptance. Of the transesophageal pacing approaches, the "pill" electrode has formerly been studied, but although this technique is effective, it has the disadvantage of causing significant discomfort. Attachment of pacing electrodes to transesophageal echocardiography probes has been reported in trials[41] [42] but has not moved into commercial production; perhaps miniaturized transnasal probes could make this feasible. The development of a small esophageal pacing catheter offers enhanced contact between the electrodes and the esophagus, which facilitates the test. In particular, the technique causes less discomfort than other pacing techniques because of the presence of smaller pacing thresholds.[43] Atrial pacing stress is more invasive than pharmacologic stress echocardiography but may be useful in patients in whom the pharmacologic approaches are contraindicated or associated with side effects. Moreover, this technique has additional attractions that might justify its use in preference to pharmacologic testing. These include the capacity to achieve a target heart rate in virtually all patients, the potential to immediately terminate the tachycardia if the patient develops complications (in contrast to pharmacologic methods, which require a period of time for the effects to dissipate), and the ability to perform measurements in the ischemic ventricle at a low heart rate (after cessation of pacing). The latter may be of particular value if Doppler indices of diastolic function are being assessed, as these are difficult to measure in the presence of tachycardia (which with dobutamine takes some time to resolve, by which time the ischemia may also have dissipated). Using atrial pacing stress, ischemic myocardium has been shown to have reduced ventricular compliance.[44] Sudden termination of stress during ischemia may also be of value in the combination of stress testing with color flow Doppler echocardiography, as the use of low frame-
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 11
rates may pose a problem at high heart 305
rates. However, despite the benefits of transesophageal atrial pacing, its availability for many years,[45] and recent data showing correlation with dobutamine echocardiography despite a shorter test duration and better patient tolerance,[43] this technique has not become widely used because it remains somewhat invasive. Combined Approaches
Atropine reduces the depressant effect of vagal stimulation on heart rate and may be particularly useful when reflex reduction of the heart rate occurs in response to blood pressure elevation. The combination of atropine with dobutamine has been found to be useful in patients who fail to develop an adequate degree of tachycardia in response to dobutamine, the most common situation involving patients taking beta receptor antagonists.[46] [47] [48] An additional component of tachycardia (and therefore ischemia due to increased oxygen demand) can also be obtained by combining atropine with dipyridamole.[49] [50] [51] In both circumstances, the addition of atropine to other stressors has been associated with an increment in sensitivity. Indeed, there is a trend toward earlier use of atropine during the dobutamine protocol,[52] [53] especially in beta-blocked patients. However, although nondiagnostic results of a submaximal heart-rate response can be avoided by the use of atropine, this adjunct does not help the results of submaximal tests that reflect premature termination of pharmacologic stress due to side effects. The rationale for combining dobutamine and dipyridamole Figure 14-2 End-diastolic apical four-chamber image in fundamental (A) and harmonic (B) modes. The use of harmonic imaging substantially improves visibility of the lateral wall and distal structures.
reflects their action through different mechanisms. The sequence of drug administration can be used to produce a stepwise stress on the heart. The initial administration of dipyridamole permits detection of the most severe coronary stenoses due to the development of coronary steal. The subsequent incremental administration of dobutamine progressively increases oxygen demand, permitting the identification of progressively
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 11
more moderate stenoses.[54] The combination has also been used to enhance the accuracy of detection of myocardial viability.[11] Although the combination of these techniques has afforded higher levels of sensitivity than the individual tests can provide, using the current methodology, this is obtained at the cost of an unacceptably long stress protocol.[54] Echocardiographic Approach to Nonexercise Stress Techniques Image Acquisition
The technical challenges of pharmacologic and pacing stress, although less extreme than those posed by exercise echocardiography (as the patient is neither moving nor hyperventilating), mandate the use of the best available echocardiography equipment. The development of harmonic imaging has made a substantial impact on endocardial visualization[55] [56] [57] (Fig. 14-2) and therefore the feasibility of stress echocardiography.[58] Although very few patients (<2%) have completely uninterpretable images, 306
failure to detect the endocardium in every myocardial segment is very common, and contrast is indicated if two to four segments are completely or partially obscured (Fig. 14-3) . Typically, transthoracic images are obtained in the four standard views (parasternal long- and short-axis and apical four- and two-chamber). Transesophageal echocardiography has been employed in combination with both pharmacologic[59] [60] [61] and pacing stress,[41] [42] [62] usually for patients with inadequate transthoracic images. During transesophageal imaging with pharmacologic stress, we approximate the standard imaging planes as closely as possible by recording transverse and longitudinal esophageal and transgastric short- and long-axis views. During pacing with electrodes attached to the transesophageal echocardiography probe, the need to stimulate the esophagus inhibits the ability to move the transducer, so that imaging is performed in the transgastric planes only. Although the constraints of a busy stress echocardiography schedule may preclude the performance of a detailed examination in every patient, a "screening" M-mode, pulsed wave (especially for left ventricular inflow), and color Doppler echocardiographic examination should be performed at the beginning of every study. Time should also be taken to optimize twodimensional echocardiographic images, gain settings (for endocardial
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 11
detection), and image size (to obtain the best spatial resolution and framerate). During the stress, the patient is imaged continuously, and the images are stored on videotape. When the study is performed for the diagnosis of coronary disease, the digital quad-screen display is filled with a resting image, a low-dose image (10 µg/kg/minute dobutamine, 0.56 mg/kg dipyridamole, or a small heart rate increment with pacing), and two highdose images (40 µg/kg/minute dobutamine or 0.84 mg/kg dipyridamole with or without atropine), or a peak and early poststress image. When a resting wall motion abnormality is present, and the clinical question pertains to the possibility Figure 14-3 Use of myocardial contrast for left ventricular opacification during stress echocardiography. Compared with harmonic imaging (A), the post-contrast end-diastolic apical four-chamber image (B) shows significant improvement of lateral wall resolution.
of viable myocardium, we obtain two low-dose images (5 and 10 µg/kg/minute dobutamine) and one high-dose image. Image Processing
Both videotape and digital techniques are used for interpretation and archiving of stress echocardiograms. Because modern echocardiography systems are fully digital, digital image capture is an easy process that permits rapid acquisition. Moreover, digital image processing facilitates image display and interpretation by allowing a side-by-side display of resting, low-dose, and high-dose images, as well as the ability to review individual frames (the latter permitting an effective evaluation of the temporal sequence of contraction). Although the use of digital echocardiography enhances the accuracy of nonexercise echocardiography, however, all studies should be recorded on videotape as well as in digital format. This provides a back-up in case technical problems with the digital capture (especially triggering) or corruption of the archived data threaten loss of the study. Indeed, routine review of videotape has a significant impact on diagnosis, probably by permitting review of off-axis images and regions that are not adequately represented by saving a single cardiac cycle. [63]
Qualitative Interpretation
The interpretation of stress echocardiograms for clinical purposes is based on a qualitative evaluation of regional function at rest and stress.[64] Some
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 11
standardization is obtained by scoring regional wall motion and thickening in a number of segments, the most widely used being a model based on that of the American Society of Echocardiography,[65] wherein the left ventricle is divided into 16 307
Figure 14-4 (Figure Not Available) Effect of a training period on the accuracy of interpretation of dipyridamole stress echocardiograms by learning and experienced groups of observers (shown at initial [Before] and follow-up [After] periods). (From Marwick T: Stress Echocardiography. Amsterdam, Kluwer Academic Publishers, 1994.)
segments (anterior, septal, lateral, and inferior at the apex, with these segments as well as anteroseptal and posterior segments at the base and midpapillary muscle level). Despite this standardization, however, the expertise of the physician interpreting the test is critical, and even accomplished echocardiographers require a significant learning period. In a study of echocardiographers learning dipyridamole stress echocardiography, Picano et al[66] reported that 100 supervised studies were required to bring the accuracy of "novices" to the level of "experts" (Fig. 14-4) (Figure Not Available) . The standard qualitative algorithm for interpretation of pharmacologic stress echocardiography is summarized in Table 14-2 . With the exception of the low-dose responses to dobutamine and dipyridamole, which denote myocardial viability (see later discussion), it may also be applied to pacing or other stressors. Regional wall motion at rest may be classified as normal, hypokinetic, akinetic, or dyskinetic. Severe hypokinesia may be difficult to distinguish from akinesia; a useful guide is based on endocardial excursion, with less than 2 mm identifying akinesia and less than 5 mm indicating hypokinesia. Regions that fail to thicken or that move only in late systole (after movement of the adjacent myocardium) may be moving passively and should be considered akinetic, irrespective of endocardial excursion. Segments with resting akinesis or dyskinesis are most likely composed of infarcted myocardium if the wall is TABLE 14-2 -- Interpretation of Myocardial Viability and Ischemia Using Dobutamine Echocardiography Resting
Peak/Poststress
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Diagnosis Normal Ischemic
Pagina 8 di 11
Function Normal Normal
Low-Dose Normal Normal (unless severe CAD)
Function Hyperkinetic Reduction vs. rest
Reduction vs. other segments Delayed contraction Viable, patent Hypo/akinetic Improvement Sustained IRA improvement Viable, Hypo/akinetic Improvement Reduction (c/w lowstenosed IRA dose) Infarction A/dyskinetic No change No change CAD, coronary artery disease; c/w, compared with; IRA, infarct-related artery. thinned and dense,[67] but in the absence of thinning are quite likely to consist of viable tissue. Indeed, hypokinetic segments are not identified as being infarcted, on the basis that residual contraction implies the presence of residual viability. Because the process of thinning and fibrosis takes some time after infarction, myocardium of normal thickness is commonly seen after recent or non-transmural infarction. Improvement of abnormal function in response to low doses of dobutamine (5 or 10 µg/kg/minute) or dipyridamole (0.28 or 0.56 mg/kg) suggests the presence of viable myocardium (Fig. 14-5) , although this finding is more reliable if the segment subsequently deteriorates, which indicates ischemia. The global left ventricular responses to dobutamine stress include an increase in cardiac output and reduction of left ventricular cavity size, although neither is as prominent with vasodilator stress. Left ventricular dilation implies multivessel or left main coronary artery disease, but this is less commonly seen with pharmacologic than exercise stress,[68] probably because of reduction of left ventricular loading. Together with an extreme inotropic response, this afterload reduction may produce cavity obliteration, and although this response is favorable prognostically (presumably reflecting a low probability of multivessel disease), it may impair sensitivity because endocardial excursion is reduced and small areas of wall motion are unrecognized.[69]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 11
The normal regional response of segments to maximal 308
Figure 14-5 End-diastolic and end-systolic freeze-frame images illustrating left ventricular enlargement at dobutamine echocardiography in a patient with left ventricular dysfunction and multivessel coronary artery disease. There is a resting wall motion abnormality in the apex, which is unchanged with stress. At peak stress, there is left ventricular enlargement with reduction of systolic motion and thickening of the lateral (and to a lesser degree the septal) wall.
inotropic stress is to increase endocardial excursion, speed of contraction, and degree of myocardial thickening. A deterioration of function from rest, or after an initial enhancement of function, indicates the development of ischemia with either dipyridamole or dobutamine (Fig. 14-6) . Variants of an overt deterioration include delayed contraction ("tardokinesis") and a reduction of myocardial thickening. Caution should be applied in the assessment of areas adjacent to zones of myocardial infarction, which may be tethered by the infarcted zone and hence fail to improve function with stress, or even appear dyskinetic if the infarct bulges during stress. Careful examination of wall thickening may assist in distinguishing peri-infarct ischemia and tethering. The diagnosis of ischemia in segments with abnormal resting function depends on the stress agent and is more difficult. At dobutamine echocardiography, if a segment shows akinesia or dyskinesia at rest, a further deterioration of function probably reflects increased loading rather than ischemia.[70] The most challenging interpretation is the diagnosis of ischemia in segments with resting hypokinesis. Segments demonstrating a stress-induced improvement are classified as normal, and those showing a deterioration (compared with either rest or low-dose) are identified as ischemic. However, differentiation between degrees of hypokinesia may be difficult, even with side-by-side cine-loop analysis. Some caution needs to be applied in the interpretation of regional variations in the degree of hyperkinesis, as these may occur in normal patients.[71] The diagnosis in hypokinetic regions that fail to improve function in response to stress is debated; if adjacent segments mount a hyperkinetic response, we characterize these as ischemic. The greatest limitations of the current application of stress
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 11
echocardiography are concerns related to subjectivity and reproducibility. Although single-center studies 309
Figure 14-6 Apical two-chamber views illustrating the development of myocardial ischemia (reduced wall thickening) of the apex during dobutamine stress echocardiography. End-diastolic images are given on the left and systolic images on the right, with resting images above and peak dose below.
have suggested that the interobserver variation in interpretation is small,[72] interinstitution variability (although similar to that of other imaging techniques) is significant.[73] Interinstitution variability is particularly a problem in studies of poor image quality and in patients with mild ischemia. This discordance has been progressively reduced by definition of standard reading criteria[74] and more recently by the adoption of harmonic imaging.[75] The following reading guidelines are useful for controlling variation: minor degrees of hypokinesia are not identified as ischemia (especially if only apparent at peak and not at poststress readings); focal abnormalities that do not follow angiographic territories are ignored; abnormalities are corroborated whenever possible with another view; basal inferior and septal segments are not identified as abnormal in the absence of a neighboring abnormal segment; studies are read by multiple observers whenever possible; and reading is blinded to all other data. Finally, we find a standard sequence to be of value in the interpretation of stress echocardiograms (both exercise and nonexercise). We first review the video images of the resting examination, including M-mode and Doppler components. On beginning the review of the digital images, we first check that images are triggered correctly and the prestress, peak stress, and poststress views are comparable. We then briefly review the side-byside display to see if there are new wall motion abnormalities or obvious changes in cavity size (suggesting multivessel disease) or cavity shape. Segmental analysis is carried out by careful comparison of regional function in each of the 16 segments, comparing the same site at rest and at stress. Both wall motion and thickening are compared, using both cine-loop and frame-by-frame review of the digital images. If image quality is not good enough to permit the use of thickening criteria, the reader should focus on the first part of systole to minimize the contribution of rotational or translational movement. Finally, videotaped stress images are examined,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 11 di 11
to review nonstandard views 310
and to check on conclusions based on the digitized images. From review of digital and video data, the site, extent (number of abnormal segments), severity (segmental wall motion score), time of onset and offset of ischemia, and the effect of ischemia on global left ventricular function can be derived.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/119.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 10
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Technical Aspects of Nonexercise Stress Techniques General Considerations The preparation for nonexercise stress testing does not deviate substantially from preparation for exercise stress testing. These tests should be performed in the fasting state, partly because nausea is a side effect with some agents (especially transesophageal pacing, dipyridamole, and adenosine), and also in case complications ensue, with attending risks of aspiration. For dipyridamole stress testing, coffee, tea, and cola drinks should be avoided for 12 hours before the examination, as xanthines antagonize the effects of dipyridamole on adenosine metabolism, as well as by direct competitive inhibition of adenosine activity. For diagnostic testing, patients should be instructed to stop anti-ischemic drugs on the day of the procedure, but medications may be continued if testing is being performed to assess the adequacy of therapy. During the preparatory stage of the test, intravenous access is secured, and electrocardiographic monitoring may be modified to remove electrodes from the echocardiographic windows. A minimum of two personnel (sonographer and physician) is mandatory for performance of these protocols, and many centers involve a nurse as well. Clinical and electrocardiographic monitoring during the tests parallels the monitoring undertaken during exercise stress testing. In addition to the usual resuscitation equipment, intravenous beta-adrenoreceptor blocking agents and nitrates should be available to treat severe ischemia, and for dipyridamole testing, aminophylline should be available for the treatment of severe ischemia, which occurs occasionally. Exercise-Simulating Agents Protocols for Administration of Sympathomimetic Agents
Dobutamine has been administered using various empirical dose regimens,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 10
but the relative plasma levels with these have not been studied, and none is clearly superior to the others. The most widely used is an incremental administration (Fig. 14-7) from 5 µg/kg/minute to 40 µg/kg/minute in 2- or 3-minute stages.[28] [29] [30] [31] [32] [33] [34] Variants include maximal doses of up to 50 µg/kg/minute and down to 20 µg/kg/minute; lower dose-rates administered over longer periods are able to attain hemodynamic effects similar to those obtained by the high-dose protocols.[33] New accelerated dobutamine protocols are currently being used to reduce the duration of the test, but whichever regimen is applied, a reasonable (i.e., 2- to 3-minute) period at peak heart rate is desirable, as ischemic wall motion abnormalities may take a short time to become apparent. If atropine is added to induce an increase in heart rate, the usual dose is 1 to 2 mg total in 0.25-mg increments. Arbutamine is no longer marketed, but other agents might be applied using a similar closed-loop computerized delivery system. The age and weight of the patient, target heart rate, and rate of heart rate augmentation (heart rate slope) were entered into the device. Based on the response to an initial dose, the microprocessor automatically increased the infusion rate to achieve the required rate of augmentation and eventually the desired peak. As the target rate was approached, the infusion was reduced and stopped. The device had a number of alarms to alert the supervising physician to responses that require attention, as well as safety features that permitted automatic shut-off of the system. Such a system could reduce the need for a nurse to increase the drug and monitor the hemodynamics. Hemodynamic Responses to Sympathomimetics
Dobutamine enhances left ventricular contractility at low doses, usually without the development of tachycardia. At doses greater than 20 µg/kg/minute, systolic blood pressure increases, and the heart rate augments to more than 100 beats per minute. Using a standard protocol without atropine, heart rate can be expected to increase to about 120 beats per minute in most patients, reflecting a heart rate increment of 40 to 50 beats per minute. In normotensive patients, the systolic blood pressure usually increases to about 170 mm Hg (an increment of 30 to 40 mm Hg), without a significant change of diastolic blood pressure. The systolic pressure response may be marked in hypertensive patients and blunted in patients with left ventricular dysfunction or multivessel coronary disease. The peak rate-pressure product increases to the range of 16,500 to 20,000. Although the development of ischemia at lower dobutamine doses and cardiac workloads indicates the presence of more extensive coronary
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 10
disease, there is too much overlap for the hemodynamic response to be a reliable predictor of one-, two-, or three-vessel disease. The hemodynamic response to dobutamine shows significant variability between patients. Beta-adrenergic blockade may attenuate the physiologic responses to dobutamine through a process of competitive antagonism at the receptor level. Patients taking beta blockers have a significantly lower heart rate response (to a peak of 90 to 100 beats per minute), and a lower double-product (to levels of around 14,000), although this may be attenuated by use of atropine. The peak systolic blood pressure is less during dobutamine than exercise, although this difference is less than with heart rate.[29] Indeed, the cardiac stress imposed by dobutamine (even at maximal dobutamine dosage) is less than that obtainable with maximal exercise testing. In several head-to-head comparisons between 311
Figure 14-7 Standard incremental dobutamine protocol, starting at 5 µg/kg/min and going to 40 µg/kg/min with incremental atropine. Images and hemodynamics are obtained at the end of each stage.
dobutamine and exercise stress in the same patients, systolic blood pressure levels were comparable, but peak heart rate and double product were significantly greater during exercise than dobutamine stress.[33] [76] [77] [78] [79] [80] [81] These disparities have important implications for the relative sensitivity of dobutamine and exercise echocardiography (see later discussion). Side Effects of Stress Testing with Sympathomimetic Agents
Other than the development of myocardial ischemia, dose-limiting side effects experienced during dobutamine protocols generally reflect intense adrenergic stimulation. Consequently, dobutamine stress is contraindicated in patients with severe hypertension and serious arrhythmias. Serious side effects are rare during dobutamine stress testing. In more than 1000 dobutamine studies reported by Mertes et al,[82] no patients died or suffered myocardial infarction or sustained tachyarrhythmias. Similarly, in 650 studies with dobutamine and atropine reported by Poldermans et al,[83] no patients died or suffered myocardial infarction, and cardiac arrhythmias were most likely in patients with left ventricular dysfunction or pre-existing
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 10
ventricular arrhythmias. In a multicenter study reported by Picano et al,[50] nine major cardiac events occurred in nearly 3000 studies (three due to ventricular tachycardia, two from ventricular fibrillation, two from myocardial infarction, one with severe ischemia, and one with hypotension). In this study, atropine psychosis was observed in five patients, but this finding has not been reported from other studies and this author has yet to see this complication in a personal experience of over 5000 studies, many of which have involved atropine usage. In our experience, serious side effects of dobutamine stress occurred in 3 per 1000 patients,[84] a similar result to that of a large German study.[85] Nonetheless, in case reports, fatalities have been reported from ventricular fibrillation and cardiac rupture.[86] Moreover, the safety of the test in patients at highest risk—those with severe left ventricular dysfunction—has been described only in small populations.[87] Nonetheless, considering that the sickest patients (those unable to exercise and those with questions of myocardial viability) undergo the test, this safety profile can be considered to be quite favorable and may in part reflect the detection of the extent and severity of ischemia by online echocardiographic imaging, permitting termination of the stress before serious problems arise. The most frequent serious but nonfatal complications are myocardial infarction and arrhythmias, although atrial fibrillation and sustained ventricular tachycardia are rare, and more common rhythm problems include atrial and ventricular extra systoles and nonsustained atrial and (less often) ventricular tachycardias. Other problems include palpitations (due to increased contractility), hypertension, anxiety (sometimes manifested as dyspnea or vagal reactions), tremor, and urinary urgency. Hypotension may arise from the vasodilator effect of high-dose dobutamine, the development of outflow tract obstruction, or the development of severe ischemia. [88] [89] [90] [91] Unlike hypotension during exercise testing, it does not denote the presence of serious coronary disease or left ventricular dysfunction. [92] All of the studies documenting the sensitivity and specificity of dobutamine stress echocardiography have documented these complications, but the recorded frequency of these side effects has varied from 5% if only serious, dose-limiting side effects are considered[28] to 82% if all side effects are included.[33] One source of variability relates to the definitions used to identify side effects. For example, in the initial experience with dobutamine stress testing, hypotension (which is usually asymptomatic) provoked termination of the test if the systolic blood pressure decreased by more than
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 10
20 to 30 mm Hg or a greater than 15 mm Hg fall from baseline, whereas most centers now continue the infusion unless the systolic blood pressure falls to less than 100 mm Hg or the patient becomes symptomatic. Another source of variability relates to the type of stress protocol, the incidence being lower if the test is terminated for attainment of a target heart rate or when echocardiographic evidence of ischemia is seen[28] or if submaximal test responses are excluded.[29] Vasodilator Stress Protocols Stress Protocols
For dipyridamole stress, an intravenous line is inserted into a large proximal arm vein to minimize local discomfort from this strongly alkaline compound. Various dipyridamole administration regimens have been used, both intravenous and oral, although the absorption of the latter is variable and the approval of the intravenous form of 312
this agent by the Food and Drug Administration has removed the main reason for using this route. For myocardial perfusion imaging, the most commonly administered dose is 0.56 mg/kg IV,[93] but this infusion protocol has unsatisfactory levels of sensitivity when combined with stress echocardiography. The sensitivity of dipyridamole echocardiography can be significantly enhanced[94] [95] by an additional 2 minutes of infusion if the initial response is negative and no major side effects have appeared. Because the time of onset of ischemia correlates with the severity of coronary disease and prognosis (see later discussion), we record images every 2 minutes from the conclusion of the first dose until 18 minutes from the start of the study. Digitized images are saved at rest, before the start of the second dose (8 minutes), after the second dose (12 minutes, which is the most common time for the onset of ischemia), and at 16 minutes. Aminophylline (in aliquots of 50 to 75 mg IV) can be used to counteract the effects of dipyridamole if severe ischemia or side effects arise; the threshold for using this agent is influenced by the overall left ventricular function and the clinical state of the patient. Because dipyridamole acts via endogenous adenosine release, there is some delay between the time of its administration and the development of its effects. In contrast, because exogenous adenosine is able to act directly, it rapidly achieves steady state, and its biologic effects are of rapid onset.[38] It
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 10
is therefore suitable for injection using an incremental dose schedule, with echocardiographic imaging at the end of each stage. Various dosing regimens have been used for echocardiographic studies, including a fixed dose of 0.14 or 0.17 mg/kg/minute and incremental protocols (3-minute stages starting at 0.10 mg/kg/minute, increasing to 0.14 and 0.18 mg/kg/minute).[96] [97] [98] [99] The use of aminophylline is rarely required for side effects, as these resolve within a minute of stopping the infusion. Hemodynamic Responses to Vasodilators
The mechanism of action of vasodilator agents is chiefly through the phenomenon of coronary steal. There is a small contribution of increasing oxygen demand from tachycardia,[23] which may be a response to angina and side effects rather than arising from the agents themselves. Similarly, blood pressure is usually little changed by these stressors, which may cause hypotension. The addition of atropine leads to an augmentation of heart rate and cardiac work, [49] [51] effectively combining reduced coronary supply with increased oxygen demand. Side Effects of Dipyridamole and Adenosine
The development of side effects during dipyridamole stress usually follows completion of the infusion and rarely precludes completion of the study. Side effects usually resolve spontaneously, but, if necessary, aminophylline can be used to reverse the effects of dipyridamole. Minor side effects, including flushing and headache (which reflect the systemic vasodilator effects of the compound), occur in about two thirds of patients studied with high-dose dipyridamole.[100] Severe or prolonged myocardial ischemia is infrequent but can be treated with nitrates or aminophylline. Serious side effects are very rare[50] [101] severe myocardial ischemia and infarction, bronchospasm, and complete heart block and even death have been reported. The frequency of these serious complications is probably less than with dobutamine, although ensuring that the comparison groups are matched for baseline risk is always difficult. Dipyridamole stress is contraindicated in patients with untreated atrioventricular block and bronchospastic disorders, although patients with chronic obstructive airway disease with no or minimal airway reactivity may undergo the test. Adenosine differs from dipyridamole stress only to the extent that the adenosine causing the physiologic effects is exogenous rather than endogenous. The side effect profile is therefore similar, and although the intensity and frequency of side effects with adenosine exceed those of
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 10
dipyridamole, they are of shorter duration. Some form of side effect occurs in most patients undergoing adenosine stress.[102] In response to a high-dose protocol, [99] side effects prevented about one third of patients from achieving peak dose, a comparable frequency to that found with dobutamine. As the effect of adenosine is very transient, cessation of the infusion is usually the only treatment required for side effects. Vasoconstrictor Protocols An increasing amount of literature has developed regarding the use of ergonovine for the diagnosis of coronary spasm, especially in regions where this diagnosis is made in the absence of fixed coronary stenoses. In the West, however, this finding is considered unusual, with spasm being recorded in 4% of patients in whom it is suspected clinically, although the return may be increased significantly by focusing on smokers and patients with some coronary disease.[103] Although most practitioners feel more comfortable with the use of this agent in the angiography laboratory,[103] because spasm can be visualized directly and intracoronary nitrates infused to treat severe spasm, a significant evidence base attests to its safety when applied noninvasively in patients without significant stenoses.[104] [105] [106] Although most of the evidence base relates to patients in whom significant stenoses have been excluded, the test has been applied to some patient groups without previous angiography.[6] [7] The standard protocol involves repeated bolus doses of ergonovine maleate at 5-minute intervals up to a total cumulative dose of 0.35 mg, unless echocardiographic evidence of abnormal left ventricular wall motion is detected. Pacing Stress Stress Protocols
The use of transesophageal pacing requires topical pharyngeal anesthesia and mild sedation. The end points of the test are the same as those for other nonexercise stressors; 313
in the absence of these end points, pacing at peak heart rate is continued for 3 minutes. No protocol has been uniformly accepted. Although formerly we used an incremental protocol commencing at 100 beats per minute, with increases in 2-minute stages, we now take the heart rate to 85% of predicted maximum immediately, followed by 100% of predicted
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 10
maximum. The benefit of a short protocol is that electrode movement and loss of capture are less likely. Atropine is often required to overcome Wenckebach's atrioventricular block. In our practice, we digitize resting, 100 beats per minute, peak, and post-pacing images and apply the usual guidelines for interpretation. Hemodynamic Responses
The hemodynamic response to pacing stress is more controllable than the response to pharmacologic agents. The heart rate is usually increased to 150 or 160 beats per minute, and systolic blood pressure is increased by only a small amount, giving a rate-pressure product of 15,000 to 20,000. In the case of atrial pacing using transesophageal imaging, the insertion of the transesophageal probe in an awake patient may itself provoke hemodynamic TABLE 14-3 -- Sensitivity and Specificity of Echocardiography with Dob 50 Patients)
Study Sawada et al
Significant Multivessel Myocard Dobutamine Stenosis Disease, n Infarctio n (% Al Patients, Protocol, Diameter, (% All N µ/kg/min % CAD) CAD) 103 30 >50 14 (40) 35 (43)
[28]
Cohen et al[29] Salustri et al
70 52
40 40
>70 >50
35 (69) 17 (46)
19 (37) 14 (38)
Marcovitz & 141 Armstrong[32] Mazeika et al 50
30
>50
47 (43)
—
20
>70
24 (67)
13 (36)
40 + atropine 40
>50
15 (32)
28 (60)
>50
74 (52)
0 (0)
66
40
>70
21 (42)
0 (0)
80
40
>50
33 (58)
15 (26)
[31]
[33]
McNeill et al
80
[46]
Marwick et al 217 [34]
Hoffmann et al[81] Previtali et al [78]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 10
Takeuchi et al 120
30
>50
37 (50)
62 (84)
40 + TEE 40 + TEE 40
>70 >70 >50
16 (76) 37 (60) 11 (9)
7 (33) 23 (37) 41 (34)
40 40 40 + dipyridamole 30 40 40
>50 >50 >50
21 (49) 16 (12) 16 (12)
9 (21) 38 (29) 38 (29)
>50 >50 >70
36 (55) 27 (67) 15 (60)
24 (37) 18 (41) 41 (39)
40 + atropine 40 + atropine 40 + atropine 40 + atropine 40 + atropine 40 + atropine
>50
42 (46)
25 (27)
>70
109 (74)
105 (71)
>50
34 (54)
0 (0)
>50
48 (40)
38 (30)
>50
122 (58)
>50
142 (61)
214 (70)
>50
113 (66)
55 (24)
>50 >50
— 15 (60)
>50
70 (64)
[214]
Prince et al[215] 81 Panza et al[59] 76 Beleslin et al 136 [79]
Senior et al[216] 61 Ostojic et al[54] 150 Ostojic et al[54] 55 Daoud et al[217] 76 54 Ho et al[218] Dagianti et al 60 [219]
Pingitore et al 110 [51]
Ling et al[220]
183
San Roman et al[221] Anthopoulos et al[222] Dionisopoulos et al[223] Elhendy et al
102 120 288 96 f
[224]
210 m Hennessy et al 219 [225]
Huang et al[226] 93 Lewis et al[227] 93 Nagel et al[228] 208
40 + atropine 40 Modified protocol 40 + atropine
—
— — 0 (0)
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Beleslin et al 168
Pagina 10 di 10
40
>50
0 (0)
40 (24)
[117]
SVD = single vessel disease, TEE = transesophageal echocardiography. changes and hence ischemia, so that "resting" transesophageal echocardiographic images may not be truly acquired at rest. Side Effects
Fewer side effects occur during transesophageal pacing than with pharmacologic stressors. The frequency of esophageal discomfort, gagging, or nausea is much lower with modern pacing electrodes. Angina may be provoked by stress but is usually self-limiting after cessation of pacing. Atrial flutter or fibrillation may also be precipitated. Esophageal injury is theoretically possible in response to high levels of stimulation over a prolonged period, but this has not been reported clinically.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/120.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 10
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Accuracy of Nonexercise Stress Echocardiography for Diagnosis of Coronary Artery Disease Dobutamine Stress Echocardiography The sensitivity and specificity of dobutamine echocardiography for the detection of coronary artery disease and results of recent studies are summarized in Table 14-3 . The 314
sensitivity for significant disease (defined as visually assessed stenoses of greater than 50% or greater than 70%) is variable between studies, with an interquartile range of 75% to 92%. The addition of atropine appears to enhance the sensitivity of the test, as does transesophageal imaging. The interquartile range for specificity ranged from 77% to 93%, which is comparable to that of exercise echocardiography. No single feature accounts for these false-positive results, although the most frequent site of false-positive results[107] is the basal inferior wall. Patients with apparent abnormalities in this segment should be identified as having coronary disease only if an adjacent segment (basal septal, mid-inferior, posterior) is also involved. One problem with assessments of sensitivity and specificity is that a 50% or 70% stenosis cutoff is arbitrary and does not take into account stenosis location or vessel size, both of which clearly influence the likelihood of an abnormal response. This concern has been addressed in several studies that have compared the results of dobutamine echocardiography with stenosis diameter at quantitative coronary angiography.[108] [109] [110] The angiographic cut-off value with the best predictive value for a positive dobutamine test was a luminal diameter of 1.07 mm, percent diameter stenosis of 52%, and percent area stenosis of 75%, of which minimal lumen diameter was found to have the best predictive value for a positive dobutamine stress test (odds
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 10
ratio, 51; sensitivity, 94%; specificity, 75%).[108] Stenoses smaller than 1 mm in diameter can be identified with a sensitivity of 86%. [109] [110] The previous analyses were limited by comparison with the anatomic severity of stenosis, whereas a more physiologic comparison would be more meaningful. Myocardial fractional flow reserve is a functional index of coronary stenosis severity that takes into account collateral flow and is calculated as the ratio of mean hyperemic distal coronary to aortic pressure. The degree of dobutamine-induced dyssynergy correlates significantly better with myocardial fractional flow reserve than percent stenosis or minimal lumen diameter, and the sensitivity of dobutamine echocardiography is significantly lower for lesions in vessels smaller than 2.6 mm than for larger vessels.[109] Because the existence of a regional wall motion abnormality identifies the presence of coronary disease, dobutamine echocardiography demonstrates higher sensitivities in patients with myocardial infarction. In patients with single-vessel coronary disease, the sensitivity of dobutamine echocardiography (ranging from 40% to 70%) is lower than in patients with multivessel disease. As dobutamine produces a less potent stress on the heart than exercise (see earlier discussion), the results of dobutamine stress are probably more susceptible to external influences than are those of exercise echocardiography or myocardial perfusion scintigraphy. This may be pertinent to the extrapolation of results from clinical trials (in which patients were carefully supervised and tested under optimal conditions, off therapy), to routine clinical practice, in which patients are often tested on therapy and are more likely to have a "suboptimal" test result because of inability to complete the protocol or interference by beta-blocker therapy.[34] Stress Echocardiography Using Other Sympathomimetic Agents Combination of echocardiography with other agents, such as epinephrine and isoproterenol, offers moderate sensitivity in the diagnosis of coronary artery disease.[111] Failure to attain higher levels of sensitivity with these compounds has in part reflected limitations in the administered dose brought about by concerns about side effects. The sensitivity of arbutamine echocardiography for the identification of ischemia was 76%, and the sensitivity for identification of coronary disease was 84%. No specificity data were obtained, but in a group at low probability of coronary disease, the normalcy was 96%.[112] As in the case of dobutamine and exercise echocardiography, the sensitivity was lower in
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 10
patients with less extensive disease and also in patients who were stressed submaximally. However, arbutamine stress echocardiography seems unlikely to be developed further for commercial reasons. Dipyridamole Stress Echocardiography Studies of more than 50 patients that address the accuracy of vasodilator stress echocardiography for the identification of coronary artery disease are summarized in Table 14-4 . The use of the low-dose (0.56 mg/kg) protocol is associated with lower sensitivities than those generally reported with the high-dose regimen, which range from 58% to 94%. The addition of atropine to dipyridamole appears to enhance the sensitivity of the test.[49] [113] In patients with single-vessel coronary disease, the sensitivity of dipyridamole echocardiography is in the range of 50%, and this has an important influence on the sensitivity of this test in comparison with dobutamine. Most studies show the specificity of the technique to be excellent. As in the case of dobutamine, the use of transesophageal imaging has enhanced the accuracy of dipyridamole stress echocardiography.[114] There appears to be more variation in the sensitivity of vasodilator stress echocardiography than for dobutamine and exercise echocardiography. The main variables that account for this heterogeneity are patient selection and the definition of "significant" disease. The use of greater than 70% diameter stenosis as a criterion of significant coronary disease has tended to enhance the sensitivity, as patients with milder stenoses (who would be more difficult to detect) are not included. Of more importance, however, are clinical factors, such as the prevalence of myocardial infarction and multivessel disease and the cessation of antianginal therapy[115] many of the more favorable results pertain to populations with a high percentage of patients with more severe coronary disease. As in the case of dobutamine stress, investigators have sought to address the accuracy of dipyridamole stress with physiologic rather than anatomic criteria of significant stenosis.[116] In 30 patients with isolated stenoses of the left anterior descending coronary artery, predictors of an abnormal dipyridamole echocardiogram were a stenotic flow reserve of less than 2.8, stenosis diameter greater than 59%, lumen diameter less than 1.35 mm, and coronary flow reserve less than 2.0, of which stenotic flow reserve was the only independent predictor of ischemia. This 315
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 10
TABLE 14-4 -- Accuracy of Vasodilator (Dipyridamole and Exercise) Ech of More Than 50 Patients)
Patients, Study N Picano et al 66 [94]
Picano et al
93
[100]
Masini et al
83
[229]
Massa et al
52
[156]
Cohen et al
50
[230]
Picano et al
445
[231]
Simonetti et al[232] Zoghbi et al
51 73
[97]
Severi et al
429
[126]
Mazeika et al[233] Picano et al
55 130
[49]
Previtali et al[78] Marwick et al[99]
80 97
Multivessel Myocardia Definition Disease, n Infarction n (% All of CAD, (% ALL CAD) Agent Dose % CAD) Dipyridamole, >70 20 (40) 9 (18) 0.56 mg/kg 48 (67) 17 (24) Dipyridamole, >70 * 0.84 mg/kg Dipyridamole, >70 24 (62) 15 (38) * 0.84 mg/kg Dipyridamole, >70 12 (23) 9 (17) * 0.84 mg/kg Dipyridamole, >70 28 (78) 16 (44) 400 mg PO 119 (46) 0 (0) Dipyridamole, >50 * 0.84 mg/kg Dipyridamole, >70 0.84 mg/kg * >75 24 (44) 38 (70) Adenosine, 0.14 µg/kg/min * 114 (46) 0 Dipyridamole, >75 * 0.84 mg/kg 30 (75) 18 (45) Dipyridamole, >70 * 1.00 mg/kg Dipyridamole, >50 — — 0.84 mg/kg + atropine 33 (58) 15 (26) Dipyridamole, >50 * 0.84 mg/kg Adenosine, >50 28 (47) 0 (0) 0.18 µg/kg/min *
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Ostojic et al [54]
Marangelli et al[123] Beleslin et al[79] Dagianti et al[219] Tawa et al[98]
Djordevic et al[234] San Roman et al[221] Pingitore et al[51] Anthopoulos et al[222] Beleslin et al[117] HG, hand grip.
Pagina 5 di 10
150 Dipyridamole, 0.84 mg/kg * 60 Dipyridamole, 0.84 mg/kg * 136 Dipyridamole, 0.84 mg/kg * 60 Dipyridamole, 0.84 mg/kg * 67 Adenosine, 0.17 µg/kg/min + HG 58 Adenosine, 200 µg/kg/min * 102 Dipyridamole, 0.84 mg/kg * 110 Dipyridamole, 0.84 mg/kg + atropine 120 Adenosine, 0.14 µg/kg/min * 168 Dipyridamole, 0.84 mg/kg *
>50
16 (12)
38 (29)
>75
19 (54)
>50
11 (9)
41 (34)
>50
15 (60)
41 (39)
>50
7 (18)
22 (55)
>50
34 (54)
0 (0)
>50
48 (40)
38 (30)
>50
0 (0)
40 (24)
—
>50
* Low-dose positivity permits conclusion of study before stated "peak" dose.
study was interesting on two grounds: First, it implies that dipyridamole identifies fewer mild stenoses than dobutamine echocardiography, and second, it identified angiographic variables of stenosis severity to relate to dipyridamole echocardiographic results better than intracoronary Doppler variables. Other studies have confirmed that the optimal angiographic cutoff point for dipyridamole stress echocardiography is 60%, as compared with 58% for dobutamine and 54% for exercise echocardiography.[117]
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 10
Vasodilator Stress with Adenosine Echocardiography The accuracy of adenosine stress echocardiography is also detailed in Table 14-4 . There is less of an evidence base for this test than for other pharmacologic approaches, and the published data show significant variations in accuracy. The most favorable results may be influenced by a high prevalence of multivessel coronary disease or prior infarction, the sensitivity being only 60% in patients with a normal electrocardiogram.[97] In patients without prior infarction, the sensitivity of this test was less than 60%.[99] The dose and duration of adenosine have an important influence on sensitivity, as does the coadministration of atropine. The accuracy of adenosine echocardiography has recently become the source of considerable interest because of the possibility of combining standard stress echocardiography and assessment of myocardial perfusion, either using contrast echocardiography or coronary flow reserve. Several studies have now shown that the intense coronary vasodilation induced by adenosine permits the comparison 316
of rest and hyperemic images using contrast echocardiography.[118] , [119] Although this comparison is certainly also feasible with dipyridamole,[120] adenosine may be superior. Similarly, coronary flow reserve may be measured at transthoracic or transesophageal echocardiography, using adenosine[121] as a vasodilator. The longer time course and less predictable peak flow with dipyridamole make this a less attractive agent, and if this is selected, high dose is certainly required. [122] Pacing Stress Echocardiography Table 14-5 details the accuracy of studies that have combined atrial pacing with echocardiography. Generally, very favorable results have been obtained with this stress, although the number of studies and patients within studies is still limited. The accuracy of both transesophageal imaging and pacing probably reflects the benefits of high-quality images as much as the role of pacing stress, as similar favorable findings have been obtained using transesophageal echocardiography with dobutamine and dipyridamole, as discussed earlier. The discrepancy between the reported accuracy in contrast with the limited application of the test is striking. Indeed, this became more prominent after
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 7 di 10
a recent landmark study[43] found that transesophageal atrial pacing had a high level of feasibility, and safety, duration, and patient acceptance were more favorable than with dobutamine stress echocardiography. Moreover, the tests showed a high level of concordance in inducing regional wall motion abnormalities. Although the lack of clinical uptake for this modality may not appear to be readily understood, the following are important issues that influence our continued use of pharmacologic stress. First, the evidence base for diagnostic, management, and prognostic information using pharmacologic agents is substantially greater than with pacing stress. Second, the pacing test is unlikely to be useful for the detection of viable myocardium, and even when this is not needed from a clinical standpoint (e.g., the patient is not being evaluated for possible revascularization), the biphasic response has been shown to facilitate the distinction of ischemia in the setting of resting wall motion abnormalities. Third, although advances in pacing catheter technology have improved patient tolerance, as documented earlier, most patients and some TABLE 14-5 -- Sensitivity and Specificity of Atrial Pacing Stress Ech Definition Sensitivity: Patients, Feasibility, of CAD, Overall, % Sensi Study N Method % % (n) SVD, Iliceto et al 85 TTE 95 >75 91 (56) 80 (2 [45]
Lambertz 50 et al[42] Zabalgoitia 36 et al[235] Kamp et al 71
TEE
100
>50 93 (41)
85 (2
TEE
90
>70 90 (21)
100 (1
TEE
99
>50 83 (52)
69 (1
TEE
94
>70 86 (20)
—
31
TTE
—
75 92 (26)
—
80
TTE
77
>75 83 (35)
75 (1
65
TTE
69
TTE
[41]
Norris et al 32 [236]
Anselmi et al[237] Marangelli et al[123] Michael et al[238] Schroder
>50 87 52
>50 82 (69)
— 82 (6
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 10
et al[239] SVD, single vessel disease; TEE, transesophageal echocardiography; TTE echocardiography. clinicians look upon the test as being excessively invasive. We believe the test will have several "niche" applications for situations in which dobutamine is unattractive: patients with hypertension or rhythm contraindications to dobutamine, potentially unstable patients (because the stress can be stopped suddenly), or patients with chronotropic incompetence of various causes. Comparison Between Nonexercise Stressors for the Diagnosis of Coronary Artery Disease Selection of the Optimal Pharmacologic Stress
It is clear from Table 14-3 and Table 14-4 that both dobutamine and vasodilator stress echocardiography are effective for the diagnosis of coronary artery disease. However, the relative efficacy of the stressors cannot be assessed by merely comparing the results of individual studies in the literature, because of variations in the study groups. The optimal study design should be based on a head-to-head comparison of the tests in the same patients, under the same conditions, as summarized in Table 14-6 . Such studies have generally demonstrated similar levels of feasibility with dobutamine and vasodilator stress. The sensitivity of dobutamine stress echocardiography has been shown to exceed that of vasodilator stress almost exclusively, although the two are close enough to be considered comparable in several studies. The main source of discrepancy appears to be patients with single-vessel coronary disease, among whom dobutamine appears to be superior to dipyridamole echocardiography. This difference parallels a significantly greater cardiac workload with dobutamine compared with vasodilator stress. As the contraindications to inotropes and vasodilators vary, the selection between them may be individualized; patients with hypertension or arrhythmias should undergo a vasodilator stress, and patients with bronchospasm or conduction disorders should be submitted to inotropic stress. However, in the majority of patients who do not have these contraindications, dobutamine appears to be the most sensitive agent for pharmacologic stress echocardiography, at least for diagnostic purposes.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 9 di 10
317
TABLE 14-6 -- Studies Comparing Sensitivity and Specificity of D Echocardiography Multivessel Myocardial Disease, n Infarction, Sensitivity: S (% All n (% All Dobutamine, Dip CAD) CAD) % 18 (72) — 76 56
CAD, Patients, n Study N (%) Martin et al 40 25 [240] (63) Salustri et al 46 18 18 (64) [152] (39) Marwick et 97 59 28 (47) [99] * al (61) 80 57 33 (58) Previtali et [78] (71) al Beleslin et 136 119 11 (9) [79] al (88) Ostojic et al 150 131 16 (12) [54] (87) Dagianti et 60 25 15 (60) [219] al (42) Anthopoulos 120 89 48 (40) [222] * et al (74) 102 63 34 (54) San Roman [221] (62) et al Loimaala et 60 44 18 (41) [205] al (73) Fragasso et 101 56 37 (65) [241] al (56) CAD, coronary artery disease.
15 (83)
79
82
0 (0)
85
58
15 (26)
79
60
41 (34)
82
74
38 (29)
75
71
41 (39)
72
52
38 (30)
87
66
0 (0)
77
77
0 (0)
93
95
0 (0)
88
61
* Adenosine used instead of dipyridamole.
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 10 di 10
Selection of Pacing Rather than Other Nonexercise Stress
Few data are available to evaluate the relative status of pacing in relation to pharmacologic approaches to nonexercise stress testing. A recent comparison of pacing to dipyridamole stress echocardiography in 80 patients with suspected coronary disease and without prior infarction[123] showed the feasibility of the test was less with pacing stress than dipyridamole (77% versus 96%, P < .0001). In patients in whom pacing and dipyridamole testing were feasible, the respective sensitivities were 83% and 43% (P = .0005), and specificities were 76% and 92% (P = NS). Although these favorable results for pacing stress may reflect the inadequacies of dipyridamole echocardiography for diagnostic stress testing, a recent comparison with dobutamine stress echocardiography recently documented[43] that transesophageal atrial pacing showed safety, duration, and patient acceptance results more favorable than those achieved with dobutamine stress echocardiography, with a high level of concordance in inducing regional wall motion abnormalities.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/121.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 2
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Assessment of Disease Significance Using Nonexercise Echocardiography In patients with known coronary artery disease, stress imaging procedures are often performed to facilitate clinical decision making, for example, regarding the referral of patients for coronary intervention. The location, extent, and severity of coronary disease can be important in this respect, and all can be determined using nonexercise echocardiography. The use of stress echocardiography for identification of the "culprit" coronary lesion is often constrained by the assumptions inherent in allocating territories of the heart to individual coronary vessels. The most ambiguous areas in this respect are the apex (usually assumed to be within the territory of the left anterior descending coronary artery) and the posterior wall (usually assumed to be supplied by the left circumflex artery). Because of the equivocal involvement of the right coronary or left circumflex vessels in the posterior territory, investigators have examined the ability to discern the presence of coronary disease in the anterior and posterior circulations. Although in the pre-harmonic imaging era the lateral wall was a source of false-negative results, the accuracy of dobutamine echocardiography in each territory appears to be equivalent (Fig. 14-8) . More severe disease in the vessel supplying an ischemic region generally correlates with a more severe wall motion disturbance. Likewise, multivessel disease usually corresponds to extensive areas of ischemia or the development of global ventricular dysfunction, or both, evidenced by poststress reduction of ejection fraction or increase of end-systolic volume, although these are much less common than with exercise, probably because of left ventricular unloading at peak stress. The presence of stenoses in multiple vessels is well known to be predictive of an adverse prognosis in patients with coronary artery disease. Consequently, the recognition of multivessel disease as such may be important in planning revascularization rather than medical therapy. The ability of dobutamine stress
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 2
echocardiography to predict multivessel disease is greatest in patients with a history of previous myocardial infarction, under which circumstances its sensitivity for the correct identification of disease is 80% to 85% and its specificity is 88%.[28] [124] In contrast, the sensitivity for multivessel disease in patients without previous infarction is approximately 70%[28] and exceeds the levels reported in this situation using exercise echocardiography. A close correlation has been demonstrated between the extent of ischemia defined by dobutamine echocardiography and perfusion scintigraphy, although both underestimate the angiographic extent of disease as measured by the Gensini score,[34] a reflection of the difficulties of assessing the functional implications of disease extent on anatomic grounds. In addition to the "space coordinate" (i.e., extent of abnormal segments),[20] another physiologic indication of the extent of coronary disease is the "time coordinate" (i.e., ischemic threshold). Using dobutamine stress, multivessel disease may also be predicted if ischemia has an early onset (similar to the "ischemia-free" time at 318
Figure 14-8 Lateral wall ischemia. Freeze-frame images in the apical four-chamber view demonstrate normal thickening at rest (above), with reduced thickening at peak stress (arrows).
exercise testing), corresponding to its occurrence at a low dose or provocation at a low heart rate and rate-pressure product.[29] [125] Similarly, at dipyridamole stress, ischemia at "standard dose" (0.56 mg/kg) correlates with the presence of multivessel disease, [100] a lower ischemic threshold at exercise testing [126] as well as a worse prognosis (see later discussion). Nonetheless, patients with severe single-vessel disease may also demonstrate an early onset of ischemia, so that this relationship is only an approximate guide to lesion severity.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/122.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 8
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Prognostic Evaluation Using Nonexercise Echocardiography Comparison of the results of nonexercise echocardiography with those of angiography validates the accuracy of these tests for diagnostic purposes and permits comparison with other noninvasive methodologies. The disadvantage of this approach, however, is that the angiographic criteria of stenotic significance are somewhat arbitrary and may not correlate with "physiologic" significance. A less artificial analysis is to use patient outcome to judge the efficacy of testing. Functional testing is commonly used for cardiac risk stratification in various groups of patients, such as those with chronic, stable angina or those who have had a myocardial infarction; for predicting complications at major noncardiac surgery; and in planning which patients should undergo coronary intervention. Prediction of Cardiac Events in Patients Undergoing Major Noncardiac Surgery Coronary artery disease is highly prevalent in patients with vascular disease elsewhere,[127] and cardiac events are the leading cause of perioperative complications at vascular surgery.[128] However, whereas coronary disease and 319
"soft" end points (postoperative unstable angina and heart failure) are frequent in patients with vascular disease, "hard" end points (death, myocardial infarction) occur in less than 10% of patients in the perioperative period, even in the absence of preoperative coronary intervention.[129] As the pretest probability of an event is low, Bayes' theorem would suggest that even if a noninvasive test were positive, the chance of an event would remain small. This explains the low predictive value of a positive test in many previous studies of stress testing in this setting. However, it is also important to remember that severe coronary
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 8
disease is also the major contributor to late deaths after vascular surgery, and the screening of vascular patients for significant coronary disease is important for both perioperative and late risk stratification. The first step in preoperative risk stratification is clinical evaluation.[130] Patients with unstable coronary syndromes within the last 6 months constitute a high-risk group and, if surgery is mandatory, warrant careful functional testing to delineate the extent of jeopardized myocardium and possible intervention preoperatively. Those with previous bypass surgery (within 5 years) or coronary investigations (within 2 years) do not require reinvestigation in the absence of recurrent symptoms. The nature of the planned surgery is important; procedures carrying low cardiac risk such as ophthalmic or laparoscopic surgery should not provoke extensive risk evaluation, whereas vascular, major orthopedic, and major abdominal operations engender significant cardiac risk. Finally, the patient history has an important influence on risk, but the standard anesthetic risk scores[131] have limited applicability among vascular patients, who have greater cardiac risk than the general surgical populations from whom these risk scores were initially obtained. A simple score derived from the patient's age, presence of diabetes, angina, prior infarction, and congestive heart failure has been shown to identify low-risk patients, who do not need further investigation.[132] In a recent series of more than 4300 patients[133] undergoing high-risk surgery, history of ischemic heart disease, congestive heart failure or cerebrovascular disease, insulin treatment, and preoperative serum TABLE 14-7 -- Use of Stress Echocardiography to Predict Events in Patients Undergoing Vascular Surgery
Study Tischler et al[242] Sicari et al [243]
Rossi et al [244]
Predictive Value, % Patients, Events, POSITIVE NEGATIVE Stress N n TEST TEST Even Dipyridamole 109 8 78 99 MI, UAP, CHF Dipyridamole 121 9 25 98 Death MI, UAP Dipyridamole 110 10 100 Death MI,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 8
Pasquet et al Dipyridamole
129
9
30
97
Dobutamine
57
4
21
100
Dobutamine
60
13
29
93
Eichelberger Dobutamine et al[247] Langan et al Dobutamine
70
5
19
100
74
3
48
100
93
4
74
100
Poldermans Dobutamine et al[250] + atropine
131
15
43
100
Poldermans Dobutamine + atropine et al[251]
181
18
32
100
Poldermans Dobutamine + atropine et al[125]
300
27
38
100
Pellikka et al[252]
Dobutamine + atropine
80
8
29
98
Ballal et al
Dobutamine + atropine
233
8
all rvs
96
[136]
Lane et al [245]
Lalka et al [246]
[248]
DavilaDobutamine Roman et al + atropine [249]
[253]
UAP Death MI, UAP Death MI, CABG Death MI, UAP MI, UAP MI, AP, CABG MI, UAP, CABG Death MI, UAP, CHF Death MI, UAP, CHF MI, AP, LVF Death MI, UAP, CHF Death MI, UAP
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 8
AP, angina pectoris; CABG, coronary artery bypass graft surgery; CHF, congestive heart failure; LVF, left ventricular failure; MI, myocardial infarction; UAP, unstable angina pectoris. creatinine level greater than 2.0 mg/dL were markers of risk; patients with none, one, two, or three or more of these factors had major cardiac complication rates of 0.4% to 0.5%, 0.9% to 1.3%, 4% to 7%, and 9% to 11%, respectively. It is important to keep in mind that patients with vascular disease are often inactive and are usually asymptomatic even in the presence of significant coronary disease. For patients at intermediate risk, stress imaging techniques with nonexercise stressors are required if screening is to be undertaken, as limitations of their exercise capacity render exercise testing approaches inadequate for the diagnosis of coronary artery disease, and the low sensitivity of pharmacologic stress electrocardiograms mandates the use of an imaging test. The relative availability and low cost of stress echocardiography, along with the potential for combining this approach with nonexercise stress, makes this an attractive technique for preoperative risk stratification. Table 14-7 shows that both dipyridamole and dobutamine stress echocardiography are effective for this purpose. The predictive value of a negative test is very high (usually greater than 90%), but as is the case with perfusion scintigraphy, the predictive value of a positive test is intermediate, varying from 20% to 70%. This value may be further stratified by paying attention to the ischemic threshold and the clinical risk factor status (Fig. 14-9) (Figure Not Available) . Clearly, the occurrence of cardiac events at the time of surgery does not only relate to the presence of coronary stenoses but is also modulated by medical treatment and anesthetic intervention. Only a handful of studies have compared stress echocardiography with single photon emission computed tomography (SPECT) for the prediction of perioperative cardiac events. From a meta-analysis of published work with dobutamine echocardiography and SPECT (mainly with dipyridamole stress), Shaw et al[134] concluded that the tests had comparable levels of accuracy but that cost features weighed in favor of echocardiography. A direct comparison by the group in Liege, Belgium showed the techniques to have similar prognostic value,[135] but another 320
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 5 di 8
Figure 14-9 (Figure Not Available) Evaluation of risk in patients undergoing vascular surgery. Patients without clinical predictors of risk rarely have a positive dobutamine study (DSE), are unlikely to suffer events, and usually do not require testing. The presence of ischemia is predictive of events, especially if the patient has multiple clinical risk factors or a low ischemic threshold. MI, myocardial infarction; neg, negative; pos, positive; preop, preoperative. (From Poldermans D, et al: J Am Coll Cardiol 1995;26:648–653.)
comparison by a different Belgian group showed echocardiography to be significantly more specific than SPECT.[136] Prognostic Evaluation of Patients with Stable Coronary Disease Although the frequency of major cardiac events is low in stable chronic coronary disease (less than 1% per year), risk stratification is an important aspect of these patients because some have been shown to have a more favorable prognosis with intervention. The detection of left main or multivessel disease at coronary angiography is often used to identify subgroups likely to benefit from revascularization, but this procedure is too costly and invasive to be used for prognostic evaluation of all patients. As in the case of preoperative risk stratification, clinical data (including the severity of angina, prior infarction, heart failure, and diabetes) may identify high- and low-risk subgroups,[137] [138] and additional investigations are of most value in those at intermediate or greater risk. Exercise capacity and ST segment depression at exercise testing offer important prognostic information in patients who are able to exercise,[139] [140] and exercise SPECT [141] or exercise echocardiography have been shown to provide incremental data in some patients.[142] In those patients who are unable to exercise, pharmacologic stress echocardiography is a useful prognostic tool (Table 14-8) . The detection of ischemia at pharmacologic stress echocardiography has been shown to be an independent predictor of adverse outcomes, incremental to clinical and resting echocardiographic data. During dipyridamole stress, cardiac events occurred in 41% of patients with wall motion abnormalities occurring at low dose and 26% of those with high-dose responses (a reflection of the prognostic importance of ischemic threshold). Even in patients with known exercise electrocardiographic and coronary angiographic data,[143] ischemia at dipyridamole echocardiography was a better predictor of cardiac events (relative risk, 1.9) than either coronary stenoses or age (relative risks, 1.3 and 1.0, respectively). Similar data have been gathered during dobutamine stress testing (see Table 14-8) . The prognostic value of pharmacologic stress appears to be preserved within various subgroups, including
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 6 di 8
hypertensive patients.[144] Few data have been gathered regarding comparisons between the stressors. Dobutamine and dipyridamole have been shown to offer effective and comparable efficacy of risk stratification in patients at low to moderate risk of cardiac events.[145] The prognostic content of stress echocardiography seems to be similar to that of SPECT.[146] The prognostic components of both tests include the presence, severity, and extent of induced ischemia. Perhaps the most important aspect of the prognostic literature is that a negative test portends extremely low risk, evidenced by an event rate of 1% or less per year. Prognostic Evaluation of Patients after Myocardial Infarction The frequency of cardiac events in the first year after myocardial infarction exceeds that in patients with chronic stable angina. Although clinical features such as age and the presence of heart failure should be used in the initial stratification of patients, the amount of infarcted and 321
TABLE 14-8 -- Use of Stress Echocardiography to Predict Events in Patie with Chronic Stable Coronary Disease Predictive Value, % Mean Patients, Follow- POSITIVE NEGATIVE TEST Comm Study Stress N up, mo TEST 51 24 68 77 High ri Mazeika et Dobutamine [254] al 77 10 50 87 Afridi et al Dobutamine [255]
Poldermans et al[256] Kamaran et al[257] Marcovitz et al[258] Schroder et
Dobutamine
430
17
26
87
Dobutamine
210
16
43
92
Dobutamine
291
15
10–17
99
Dobutamine
134
19
31
94
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
al[259] Steinberg et al[260]
Pagina 7 di 8
Dobutamine
Senior et al Dobutamine
120
60
67
67 All eve
13 121
15
45
95 Hard events 88
860
52
14
96
13
—
1659
36
8–20
539
36
26
539
36
41
94
134
19
27
92
[261]
Chuah et al Dobutamine [262]
Davar et al Dobutamine
72 F
[263]
Poldermans Dobutamine et al[264] Picano et al Dipyridamole [144] (high dose) Dipyridamole (low dose) Schroder et Dipyridamole al[259]
100 Norma studies 96 Hard events 94
residual ischemic myocardium are major determinants of outcome that cannot be quantified clinically. Previously, the techniques used for this purpose included the exercise electrocardiogram, resting echocardiography, nuclear ventriculography, and thallium imaging. In a comparison of these alternatives,[147] the optimal approach for prediction of postinfarction complications was shown to be thallium imaging and nuclear ventriculography. Stress echocardiography, however, offers a means of replacing these two tests with one. Ischemia may be assessed as homozonal dyssynergy (peri-infarct ischemia) or heterozonal dyssynergy (multivessel disease), and infarction may be estimated from the resting wall motion score index. Exercise testing offers prognostically important adjunctive data on functional capacity. However, the majority of the postinfarction stress echocardiography literature (Table 14-9) concerns pharmacologic stress studies for three reasons: first, nonexercise studies are useful in patients who cannot exercise; second, they are useful for assessment of myocardial viability (see later discussion); finally, they provide an opportunity for
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 8 di 8
obtaining a near-maximal stress reading early in the patient's admission, before many patients and physicians feel comfortable about performing maximal exercise stress testing. The last aspect is perhaps the most important, as early risk evaluation may identify at-risk patients before the occurrence of an event, permitting a reduction in hospital length of stay for low-risk patients and justifying angiography and possible intervention in those at higher risk. Both pharmacologic and atrial pacing stress tests have been used for risk assessment after myocardial infarction. All have proven to be effective for the detection of multivessel disease[124] [148] [149] and predictive for the subsequent development of cardiac events. Although atrial pacing is very safe (as the stress may be terminated instantly), it remains invasive and uncomfortable, and the pharmacologic techniques are best validated for this purpose. Moreover, the use of pharmacologic stress permits evaluation of myocardial viability, the detection of which has important implications for revascularization decisions. Table 14-9 summarizes the prognostic implications of positive and negative nonexercise stress echocardiography in patients after infarction. With dipyridamole stress echocardiography, the presence of ischemia and its time of onset are important predictors of cardiac events[150] in elderly patients, ischemia was an independent predictor of mortality.[151] An equivalent evidence base has been reported with dobutamine in the postinfarct period.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/123.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 4
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Evaluation of Therapy Using Nonexercise Echocardiography Medical Therapy In contrast to myocardial perfusion scintigraphy, the identification of ischemia with stress echocardiography is dependent on the development of ischemia. This is a disadvantage to the extent that antianginal therapy reduces the sensitivity of stress echocardiography, particularly when dipyridamole stress is used.[115] Patients on beta blockers account for most patients who fail to attain a heart rate greater than 85% of age-predicted maximum. With dobutamine echocardiography, the interaction between dobutamine and beta blockers involves competitive inhibition, and if enough dobutamine is administered, this effect may be overcome, leading several studies to suggest that concurrent drug therapy has no effect.[152] Atropine can be used to enhance the sensitivity of dobutamine stress testing, without reducing specificity or inducing serious side effects. The interaction between medical therapy and the development of ischemia may be of use in evaluating the adequacy of therapy.[153] [154] Although some data are being gathered with exercise echocardiography, the role of nonexercise stress remains largely unexplored. [155] In large part, this lack of data reflects the subjectivity of wall motion scoring, and use of stress echocardiography should become more feasible with a truly quantifiable approach. Follow-up after Coronary Interventions After angioplasty and bypass surgery, recurrent symptoms of chest discomfort may result because of restenosis 322
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 4
TABLE 14-9 -- Application of Nonexercise Stressors to Post
Patients, FollowStudy Year N Timing Stress up, mo Outcomes Iliceto[44] 90 83 <3 wks Atrial Pacing 14 Reinfarction, angina Res * 95 69 3–5 Atrial Pacing 12.6 Cardiac death, days reinfarction, revascularizatio 217 Dipyridamole 24 Cardiac death Bolognese 92 [202]
Sclavo †
92
103 5–8 days
Dipyridamole 14.5
Picano[49] 93 Chiarella ‡ 94
925 10 days Dipyridamole 251 70 hrs Dipyridamole
Picano § 95 Neskovic 95
1080 10 days Dipyridamole 93 2–3 Dipyridamole wks
Cardiac death, reinfarction Cardiac death, reinfarction, angina Cardiac death
Cardiac death, reinfarction Cardiac death, reinfarction, angina 14 Cardiac death 13 days Cardiac death Cardiac death, reinfarction Cardiac death, reinfarction, angina 14 Reinfarction 16 Cardiac death Cardiac death,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Sclavo ¶
Pagina 3 di 4
97
Lanzarini 96
60 3–4 days
Dipyridamole 15
41 8 days Dobutamine
7.5
[129]
Carlos £
97
214 2–7 days
Sicari[166]
97
778 12 days Dobutamine
9
Greco
97
178 12 days Dobutamine
17
Previtali
98
152 9 days Dobutamine
15
Dobutamine
>12
reinfarction Cardiac death, reinfarction, angina Cardiac death, reinfarction, angina, revascularizatio Reinfarction, angina, revascularizatio Cardiac death, reinfarction, angina, ventricular tachycardia, congestive hea failure Cardiac death Cardiac death, reinfarction Cardiac death, reinfarction, angina Cardiac death Cardiac death, reinfarction Cardiac death, reinfarction, angina Cardiac death
[30]
Cardiac death, reinfarction Cardiac death, reinfarction,
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Picano[237] 98
Pagina 4 di 4
314 12 days Dobutamine
9
angina Cardiac death Cardiac death, reinfarction Cardiac death, reinfarction, angina
* Res et al: Am J Cardiol 1995;76:1112–1114 † Sclavo et al: Eur Heart J 1992;13:1348–1355 ‡ Chiarella et al: Eur Heart J 1994;15:842–850 § Picano et al: J Am Coll Cardiol 1995;26:908–913 Neskovic et al: Am Heart J 1995;129:31–39 ¶ Sclavo et al: G Ital Cardiol 1997;27:1000–1007 £ Carlos et al: Circulation 1997;95:1402–1410 Greco et al: J Am Coll Cardiol 1997;29:261–267
and graft closure, respectively. Because angioplasty is most often performed for single-vessel disease, routine exercise testing is usually considered to be insensitive for the diagnosis of restenosis, and exercise echocardiography or exercise myocardial perfusion imaging are often performed. Pharmacologic stress echocardiography performed before and after angioplasty has been shown to predict resolution of ischemia using dipyridamole[156] [157] and dobutamine stress.[158] [159] If the patient cannot exercise, pharmacologic stress echocardiography can be used effectively for the diagnosis of restenosis,[160] [161] the sensitivity being significantly greater than that of the stress electrocardiogram.[162] Similarly, after bypass surgery, stress imaging tests are usually obtained for diagnostic purposes (because the resting eletrocardiogram is often nondiagnostic). Exercise echocardiography has been shown to be accurate in this context, and if the patient cannot exercise, pacing or pharmacologic stresses can reasonably be used.[163] [164] The major application of echocardiography and perhaps stress echocardiography after revascularization, however, is to assess the improvement of dysfunctional but viable myocardium.[165]
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/124.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 4
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
Assessment of Myocardial Viability Using Nonexercise Echocardiography Clinical Significance Left ventricular dysfunction after myocardial infarction is due not only to loss of myocardium but also to stunned and hibernating myocardium. Stunned myocardium shows spontaneous resolution of dysfunction,[166] but hibernating tissue requires myocardial revascularization to 323
resume normal function.[167] [168] Myocardial revascularization in patients with viable myocardium may be indicated to improve cardiac function or overall functional capacity, as well as to avoid subsequent cardiac events from this inherently unstable tissue. Thus, clinical decisions about whether to revascularize, which vessel to revascularize, and how to do it may be influenced by the detection of viable myocardium. In the following section, evaluation of the accuracy of various tests for the identification of viable myocardium is based on recovery of function after myocardial revascularization. This criterion is an imperfect gold standard, being influenced by the adequacy of revascularization, bypass graft closure, and restenosis, but it has the attraction of having direct clinical relevance. By this criterion, conventional techniques used for the detection of myocardial scar and viability (Q waves on the electrocardiogram, regional left ventricular dysfunction at ventriculography, and "fixed" perfusion defects at conventional scintigraphic procedures) have been found to be inaccurate. More accurate alternatives include position emission tomography and thallium scintigraphy using rest-redistribution or stressredistribution-reinjection protocols, both of which have a high negative predictive value.[169] A positive test result is less predictive of functional recovery, however, probably manifesting the sensitivity of these tests for
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 4
small regions of viable myocardium that may not be able to contribute to regional function when revascularized. The use of dobutamine and dipyridamole stress echocardiography to detect viable myocardium has a large evidence base and is now part of standard practice. Use of Dobutamine Echocardiography for the Diagnosis of Viable Myocardium Administration of sympathomimetic agents (such as isoproterenol, dopamine, and dobutamine) has been shown to reverse postischemic left ventricular dysfunction.[170] [171] [172] [173] The typical response of viable myocardium is to increase thickening in response to low doses of dobutamine; in the presence of a stenosed infarct-related artery, function subsequently deteriorates as the tissue becomes ischemic. Indeed, there is a balance between the recovery of function and the development of ischemia, and, at least in theory, the development of ischemia may compromise the functional recovery of areas that are marginally perfused at rest. The highdose response (>20 µg/kg/minute) has been shown to be a less reliable predictor of recovery.[8] Although some investigators start at lower doses, or use only a low-dose protocol for the assessment of viability, and others use 5-minute rather than 3-minute increments, [174] there does not appear to be a clear benefit in favor of any of these alternatives. Dipyridamole has been shown to enhance both segmental shortening and load-independent indices of ventricular function in stunned myocardium.[175] The mechanism of this phenomenon is unclear, but a "local Frank-Starling response" (whereby augmentation of myocardial blood volume leads to increased sarcomere separation) appears to be the most likely explanation. Additionally, an indirect sympathomimetic response to dipyridamoleinduced ischemia may contribute to improvement of regional function, as may resolution of ischemia secondary to improvement of coronary perfusion. Dipyridamole appears to be an effective alternative in low-dose and "infra-low-dose" protocols[176] the choice of agent is dependent on local expertise and preference. The interpretive criteria are similar, irrespective of the stressor. Viable segments are characterized by reduced resting function, which augments in response to low-dose dobutamine (usually 7.5 to 10 µg/kg/minute). There is continued augmentation if there is a patent infarct-related artery or the tissue is well collateralized. In the presence of a stenosed infarct-related artery, an increasing proportion of segments become ischemic at dobutamine doses greater than 10 µg/kg/minute.[177] This initial
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 4
improvement followed by deterioration in function constitutes the "biphasic response," which is strongly predictive of eventual functional recovery of the tissue.[177] A uniphasic response is less predictive of recovery, and a classic ischemic response is not very predictive of the recovery of resting function. Because the biphasic response is the most reliable finding (Fig. 14-10) , our preference is to induce ischemia whenever possible by proceeding to maximal stress (i.e., 40 µg/kg/minute dobutamine with or without atropine), rather than using a discreet "viability" or low-dose protocol. In patients with severe left ventricular dysfunction, this approach warrants caution, and early termination may be needed if ischemia is progressive or if other responses might induce instability. Finally, viability studies are the most difficult to interpret, and we commonly use both digital display, including doses of both 5 and 10 µg/kg/minute, and videotape for review of the study. The response of regional function to dobutamine is influenced by the extent of viable tissue, the degree of residual stenosis, the extent and magnitude of collateral vessels, the size of the risk area (which influences tethering), and the presence of drug therapy,[178] of which the extent of viable tissue and perfusion warrant further attention. The uniphasic response is an ambiguous signal that may be caused by part of the wall mounting a dobutamine response (i.e., admixture of scar and normal tissue) or all of the wall mounting a partial response (i.e., viable myocardium). The ability to discriminate the extent of subendocardial damage, with its implications for the likelihood of subsequent functional recovery, is poor. With respect to perfusion, augmentation of function is dependent on delivery of more substrate; thus, tissue supplied by more severe stenosis may become ischemic before it augments function. This may compromise the recognition of viability. The accuracy of dobutamine for prediction of regional functional recovery is summarized in Table 14-10 , although there is a large evidence base, most studies are relatively small and derive from expert centers. The overall sensitivity of dobutamine (approximately 80%) appears greater than that of dipyridamole stress (approximately 60%), although the specificity of the former is less (78% vs. 87%). Moreover, the nuclear approaches are more sensitive but less specific than these echocardiographic techniques.
324
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 4
Figure 14-10 Apical four-chamber diastolic (right) and systolic (left) views at rest (top), with low-dose dobutamine (middle), and with peakdose dobutamine (below), illustrating a "biphasic" response to dobutamine stress (reduced systolic thickening at rest, increment with low dose, and deterioration at peak dose) in the lateral wall.
Prediction of Recovery of Global Function and Outcome Improvement of left ventricular function within individual segments is not usually the goal of revascularization, whereas improvements in ejection fraction, exercise capacity, and outcome are therapeutic goals. Recent work has sought to address the ability to predict these parameters. Stress echocardiography can be used to predict improvement of global left ventricular function after revascularization. Cornel et al[179] has reported an 89% sensitivity and 81% specificity for prediction of a significant (5%) improvement in ejection fraction, using a cut-off point of 4 of 16 viable (biphasic) segments at dobutamine echocardiography. Similarly, the global ventricular response to low-dose dobutamine is a strong predictor of global functional recovery.[180] Other factors clearly influence the likelihood of recovery, including an inverse relationship with the number of thinned and akinetic segments or ventricular volumes. [181] The revascularization of patients with adequate amounts of viable myocardium (usually >25% of left ventricular mass) is associated with improved functional class. The presence of viable myocardium may influence outcome in two ways. First, revascularized viable tissue may lead to improved function and thereby improved outcome.[182] Second, non-revascularized viable tissue may be unstable and act as a substrate for recurrent events,[183] including mortality.[184] These outcomes have not been reported in all series,[185] probably because of heterogeneity in populations studied and responses; for example, a uniphasic response early after infarction may be a benign finding.
MD Consult L.L.C. http://www.mdconsult.com Bookmark URL: /das/book/view/26070721/1031/125.html/top
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 1 di 6
MD Consult information may not be reproduced, retransmitted, stored, distributed, disseminated, sold, published, broadcast or circulated in any medium to anyone, including but not limited to others in the same company or organization, without the express prior written permission of MD Consult, except as otherwise expressly permitted under fair use provisions of U.S. Copyright Law. Subscriber Agreement
Otto: The Practice of Clinical Echocardiography, 2nd ed., Copyright © 2002 W. B. Saunders Company
New Technologies that May Solve Limitations of Stress Echocardiography Image Quality Although perfect image quality is certainly not essential for a stress echocardiographic study to be interpretable, 325
TABLE 14-10 -- Sensitivity and Specificity of Dobutamine Echocardiogra for Identification of Myocardial Viability (Segmental Analysis) * Study Pierard †
Stress Dobutamine
Smart * [8]
Dobutamine
Previtali[30]
Dobutamine
Cigarroa ‡ Marzullo[275] Alfieri § Watada
Dobutamine Dobutamine Dobutamine Dobutamine
La Canna ¶ Dobutamine Dobutamine Charney[276] Perrone-Filardi Dobutamine
Patients, Sensitivity, Specificity, N % (n) % (n) Comm 17 83 (6) 73 (8/11) Early p MI 51 86 (22) 90 (26/29) Early p MI 42 79 (63) 70 Early p (109/158) MI 25 82 (11) 86 (12/14) 14 82 (49) 92 (24/26) 14 91 (93) 78 (25/32) 21 83 (66) 86 (43/50) Early p MI 33 87 (205) 82 (89/109) 17 71 (31) 93 (27) 18 88 (48) 87 (27/31)
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 2 di 6
£
Afridi Arnese[70]
Dobutamine Dobutamine
20 74 (38) 38 74 (33)
Senior[110] Bolognese[202]
Dobutamine Dobutamine
45 87 (45) 30 89 (27)
73 (55/76) 95 (130/137) 82 (123) 91 (45)
Poli #
Dobutamine
51 72 (78)
68 (176)
Dipyridamole
51 51 (78)
82 (176)
40 40 36 73
40 79 (73)
94 (133) 94 (133) 63 (65) 86 (238/277) 83 (36)
53 69 (32) 86 (50) 30 89 (62) 18 68 (46)
100 (26) 57 (46) 82 (106) 83 (63)
Varga[10]
Dipyridamole Dobutamine Dobutamine Bax[283] Vanoverschelde Dobutamine
78 (40) 76 (40) 85 (27) 76 (167)
[285]
Perrone-Filardi Dobutamine
Early p MI Early p MI Early p MI
[282]
Furukawa[67] Cornel[87] Nagueh[279]
Dobutamine Dobutamine Dobutamine Dobutamine
Total
Dobutamine Dipyridamole
Akinet Hypok Biphas respon
726 81 78 (1065/1312) (1401/1796) 91 60 (71/118) 87 (269/309)
MI, myocardial infarction. * Average ejection fraction approximately 35%. † Pierard et al: J Am Coll Cardiol 1990;15:1021–1031 ‡ Cigarroa et al: Circulation 1993;88:430–436 § Alfieri et al: Eur J Cardiothoracic Surgery 1993;7:325–330 Watada et al: J Am Coll Cardiol 1994;24:624–630 ¶ La Canna et al: J Am Coll Cardiol 1994;23:617–626 £ Perrone-Filardi et al: Circulation 1995;91:2556–2565
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 3 di 6
Afridi et al: Circulation 1995;91:663–670 # Poli et al: Heart 1996;75:240–246
it certainly favors concordance between observers[73] and facilitates an accurate diagnosis of disease extent and distinction of ischemia and scar. Major improvements in image quality obtained from harmonic imaging have translated into improvements in the accuracy of stress echocardiography.[58] Likewise, the use of contrast echocardiography may facilitate delineation of the endocardial border; the implications of this finding are addressed in another chapter. Quantitative Approaches to Interpretation As mentioned earlier, the current qualitative algorithm for interpretation of stress echocardiograms requires a significant level of expertise on the part of the observer. A less subjective means of interpretation would be attractive on the grounds of feasibility and reproducibility. Either semiquantitative or fully quantitative strategies of examining wall motion can be used to evaluate global and regional left ventricular function. Global indices (ejection fraction or end-systolic volume) are insensitive to milder degrees of ischemia and are not an answer to the shortcomings of qualitative interpretation. Wall motion scoring offers a semiquantitative regional approach, which may improve the reproducibility of observers, but this does not constitute a major deviation from the regional approach used by most experienced readers and does not measure function independent of the observer. True quantitation of regional function may be based on following either radial or longitudinal myocardial motion (see Chapter 5) . The simplest approach involves tracing of endocardial (and for some methods, epicardial) interfaces and their superimposition using a fixed or floating reference system and measurement of endocardial excursion or myocardial thickening. Historically, this approach has been limited by three major technical limitations, but recent developments have addressed some of these limitations. First, excellent border definition of both endocardium and epicardium (especially in the apical views) was obtainable in less than 50% of images, but harmonic imaging has improved image quality substantially, and contrast echocardiography may also be of value. Second, failure to
mhtml:file://D:\Documents%20and%20Settings\Administrator\Desktop\Otto\ECOCA... 06/02/2005
Book Text
Pagina 4 di 6
compensate for rotational or translational cardiac movement may be associated with false-positive results, but correction for movement of the heart may also compromise sensitivity. A postprocessing approach (using color-enhanced digitized cine-loops) may be used to correct translational movement.[186] Third, the 326
process of tracing multiple systolic and diastolic frames is tedious, timeconsuming, and unattractive for clinical practice. However, recent developments in edge-tracking have led to automated programs for measuring endocardial excursion. Along similar lines, Perez has developed an online quantification of ventricular function during dobutamine echocardiography using acoustic quantification.[187] The feasibility and accuracy of this approach has now been documented in several studies[188] [189] (Fig. 14-11) (Figure Not Available) . Myocardial tissue Doppler may provide another me