HANDBOOK ON RADIATION PROBING, GAUGING, IMAGING AND ANALYSIS
This page intentionally left blank
Handbook on Radiation Probing,
Gauging, Imaging and Analysis
Volume II:
Applications and Design
by
ESAM M.A. HUSSEIN Department of Mechanical Engineering, University of New Brunswick, Fredericton, New Brunswick, Canada
KLUWER ACADEMIC PUBLISHERS NEW YORK, BOSTON, DORDRECHT, LONDON, MOSCOW
eBook ISBN: Print ISBN:
0-306-48403-X 1-4020-1295-0
©2004 Kluwer Academic Publishers New York, Boston, Dordrecht, London, Moscow Print ©2003 Kluwer Academic Publishers Dordrecht All rights reserved No part of this eBook may be reproduced or transmitted in any form or by any means, electronic, mechanical, recording, or otherwise, without written consent from the Publisher Created in the United States of America Visit Kluwer Online at: and Kluwer's eBookstore at:
http://kluweronline.com http://ebooks.kluweronline.com
Dedicated in memory of my Father Mahmoud, my Uncle Roshdi, and my Aunt Alia.
This page intentionally left blank
Contents
Preface Acknowledgments
xix xxi
Foreword
xxiii
VOLUME TWO: APPLICATIONS AND DESIGN
441
PART III:
443
APPLICATIONS
10. PROBING, INSPECTION AND MONITORING 10.1 Surface Condition 10.2 Damage and Flaw Detection 10.3 Residual Stresses 10.4 Flow Obstruction 10.5 Monitors 10.5.1 Process Monitoring 10.5.2 Smoke Detectors 10.5.3 Radon 10.5.4 Other Gases 10.6 Hidden Materials 10.6.1 Industrial Materials 10.6.2 Radioactive Materials 10.6.3 Illicit Materials
447 447 454 456 457 458 458 460 460 462 463 463 463 464
11. GAUGING 11.1 Bulk Density 11.1.1 Alpha-Particle Transmission
465 465 466
vii
viii
Radiation Probing, Gauging, Imaging and Analysis
11.2
11.3 11.4 11.5
11.6
11.1.2 Beta-Particle Transmission 11.1.3 Beta-Particle Scattering 11.1.4 Photon-Based Methods Thickness 11.2.1 Charged Particles 11.2.2 Photon Transmission 11.2.3 Photon Scattering 11.2.4 X-ray Emission 11.2.5 Neutrons 11.2.6 Composition-Independent Porosity and Voidage Water (Moisture) Content Measurements in Fluid Flow 11.5.1 Density 11.5.2 Flow-Rate by Radiotracers 11.5.3 Gas Flow-Rate by Ionization 11.5.4 Flow-Rate by Pulsed-Neutron Activation
11.5.5 Level Measurement 11.5.6 Liquid-Liquid Interface 11.5.7 Leak Detection 11.5.8 Volume 11.5.9 Gas Properties 11.5.10 Flow Distribution 11.5.11 Void Fraction 11.5.12 Multiphase Flow 11.5.13 Isotope Hydrology Dating
12. ELEMENTAL AND CONTENT ANALYSIS 12.1 Nucleus-Based Analysis 12.1.1 Activation Analysis 12.1.2 Passive Emission 12.1.3 Resonance Effects 12.1.4 Fast-Neutron Scatteroscopy 12.1.5 Charged-Particle Scatteroscopy 12.2 Atom-Based Analysis 12.2.1 Fluoroscopic Excitation 12.2.2 Composition Indication 12.3 Hydrogen Measurement 12.3.1 Neutron Slowing-Down 12.3.2 Scattering into Resonances 12.3.3 Beta Particles 12.3.4 Compton Scattering 12.3.5 Cold Neutrons
467 468 468 474 475 476 478 479 482 482 483 484 489 490 491 494 494 495 502 503 506 507 510 511 515 517 518 521 522 522 544 549 553 554 556 556 562 571 574 579 582 584 585
Contents
ix
12.4 Material Content Analysis 12.4.1 Alpha Particles 12.4.2 Beta Particles 12.4.3 Photons 12.4.4 Neutrons 12.4.5 X-ray Fluoroscopic Emission 12.4.6 Mössbauer Spectroscopy 12.4.7 Natural Radioactivity 12.4.8 Combined Techniques
585
586
587
591
595
603
604
604
604
13. IMAGING 13.1 Photon Radiography 13.1.1 Film Radiography 13.1.2 Radioscopy 13.1.3 Flash Radiography 13.1.4 Microfocus Radiography 13.1.5 Megavoltage Radiography 13.1.6 Low-Energy Radiography 13.1.7 Bremsstrahlung Radiography 13.1.8 Laminography 13.1.9 Scatterography 13.1.10 Emission Imaging 13.1.11 Diffraction Imaging 13.2 Neutron Radiography 13.3 Charged-Particle Radiography 13.3.1 Autoradiography 13.4 Tomography 13.4.1 Photon Tomography 13.4.2 Neutron Tomography 13.4.3 Scatter Imaging 13.4.4 Emission Tomography 13.4.5 Proton Tomography 13.5 Imaging for Material Content 13.5.1 Dual-Energy Imaging 13.5.2 Critical-Edge Tomography 13.5.3 Transmission/Scatter Imaging 13.5.4 Photon Coherent-Scatter Imaging 13.5.5 Emission Imaging
607
607
607
608
611
612
613
614
615
615
617
619
621
621
628
630
633
633
638
639
640
640
641
641
641
642
643
644
PART IV:
DESIGN
14. PERFORMANCE PARAMETERS AND DESIGN ASPECTS 14.1 Performance Parameters
647
653
653
x
Radiation Probing, Gauging, Imaging and Analysis
14.2 Statistical Optimization 14.3 Design Objectives 14.4 Source Selection 14.4.1 Radiotracers 14.4.2 Source Generation 14.4.3 Source Energy 14.4.4 Interfering Radiation 14.5 Selection of Technique 14.6 Detection System 14.6.1 Detector Selection 14.6.2 Electronics 14.6.3 Detector Collimation 14.6.4 Filtration
659
662
663
665
666
667
670
671
673
673
674
675
678
15. SOURCE MODULATION 15.1 Source Collimation 15.1.1 Design Parameters 15.1.2 Geometry 15.1.3 Beam Profile 15.1.4 Divergence and Alignment 15.1.5 Collimation of Charged-Particles 15.1.6 Photon Collimation 15.1.7 Fast-Neutron Collimation 15.1.8 Collimation of Thermal-Neutrons 15.2 Filtering 15.2.1 X-Rays 15.2.2 Neutrons 15.3 Neutron Moderation 15.3.1 Moderating Materials 15.3.2 Moderating by Containment 15.3.3 Block Moderation 15.3.4 Moderation by Reflection 15.4 Neutron Multiplication
681
681
681
683
686
687
688
688
689
692
695
695
699
705
705
710
712
714
716
16. DESIGN CALCULATIONS 16.1 Design Parameters 16.2 Monte Carlo Simulation 16.3 Shielding 16.3.1 General 16.3.2 X-Ray Machines 16.3.3 Isotopic Gamma Sources 16.3.4 Neutrons 16.3.5 Computer Codes
719
719
720
728
728
732
734
735
735
Contents
xi
17. EXPERIMENTS 17.1 Experimental Aspects
17.2 Licensing
17.2.1 General
17.2.2 X-Ray Machines
17.2.3 Radioisotopes
17.2.4 Particle Accelerators
17.3 Background Reduction
17.3.1 Definition and Origin of Background
17.3.2 In Transmission
17.3.3 In Scattering
17.3.4 In Emission
17.4 Dynamic Analysis
17.4.1 Expected-Value Analysis
17.4.2 Frequency Analysis
17.4.3 Movement
739 739 742 742 746 748 749 751 751 752 754 756 757 758 759 761
18. FINALIZATION 18.1 Prototyping
18.2 Intellectual Property Protection
763 763 766
A.
Basic Units and Constants
xxvii
B.
List of Elements and Natural Isotopes
xxix
C.
Relativistic Mechanics
xxxv
D.
Quantum Mechanics D.1 Preliminaries D.2 Schrödinger Equation D.3 Concept of Cross-Section D.4 Quantum Electrodynamics
E.
Nuclear/Atomic Parameters for Compounds and Mixtures E.1 Atomic Density E.2 Electron Density E.3 Macroscopic Cross-Section E.4 Effective Mass and Atomic Numbers E.4.1 Electron-Density Based E.4.2 Reaction Cross-Section Based E.4.3 React ion-Ratio Based
F.
Effective Energy F.1 Mean Energy
xxxix xxxix xli xlvi l liii liii liv lv lvii lvii lvii lviii
lxi lxi
xii
Radiation Probing, Gauging, Imaging and Analysis
F.2 Most Probable Energy F.3 Cross-Section Dependent F.4 Best Match G.
Radiation Counting Statistics G.1 Poisson Statistics G.1.1 Mean and Variance G.1.2 Population Statistics G.2 Gross/Background Count Rates G.2.1 Net Count Rate G.2.2 Number of Measurements and Counting Period G.3 Goodness of Data G.4 Current-Mode Statistics G.5 Elemental Error
References
lxii
lxii
lxii
lxv lxv
lxvi
lxvii
lxviii
lxviii
lxix
lxx
lxxii
lxxv
lxxvii
About the Author
clxxxvii
Application Index
clxxxix
Index
cxcix
Contents
Preface Acknowledgments
xix
xxi
Foreword
xxiii
VOLUME ONE: BASICS AND TECHNIQUES
1
1. INTRODUCTION 1.1 Why Radiation 1.2 Nondestructive Examination (NDE) 1.3 Conventional NDE Methods 1.4 Elements of NDE 1.5 Intricacy of Radiation Methods
3
3
4
6
9
10
PART I:
15
BASICS
2. RADIATION TYPES AND SOURCES 2.1 Charged Particles 2.1.1 Alpha Particles 2.1.2 Beta Particles 2.1.3 Discrete-Energy Electrons 2.1.4 Positrons 2.1.5 Heavy-Charged Particles 2.2 Photons 2.2.1 X-ray Machines 2.2.2 Low-Energy Photon Sources 2.2.3 Primary Gamma Rays 2.2.4 Indirect Gamma Rays 2.3 Neutrons 2.3.1 Fast Neutrons 2.3.2 Intermediate-Energy Neutrons 2.3.3 Slow Neutrons 2.3.4 Cold Neutrons 2.4 Natural Sources
xiii
19
19
19
21
25
26
29
30
31
36
44
46
46
48
55
56
58
59
xiv
Radiation Probing, Gauging, Imaging and Analysis
3. MODIFYING PHYSICS 3.1 General 3.2 Cross Sections 3.2.1 Microscopic Cross-Section 3.2.2 Differential Cross-Section 3.2.3 Macroscopic Cross-Section 3.3 Charged Particles 3.3.1 Alpha Particles 3.3.2 Beta Particles 3.4 Photons 3.4.1 Photoelectric Absorption 3.4.2 Incoherent/Inelastic (Compton) Scattering 3.4.3 Coherent/Elastic Scattering 3.4.4 Pair Production 3.4.5 Photo-nuclear Interactions 3.5 Neutrons 3.5.1 Elastic Scattering 3.5.2 Inelastic Interactions 3.5.3 Absorption 3.5.4 Fission and Multiplicity Reactions 3.5.5 Coherent Scattering 3.5.6 Cross Sections 3.6 Radiation Transport 3.6.1 Classical Laws of Conservation 3.6.2 Divergence Law 3.6.3 Attenuation Law 3.6.4 Diffusion Theory 3.6.5 Transport of Charged-Particles 3.7 Radioactive Decay 3.7.1 Kinetics of Decay 3.7.2 Parent / Daughter Decay 3.7.3 Equilibrium 3.7.4 Decay Chains
63
63
66
66
67
67
70
71
75
78
81
82
92
95
99
99
100
103
105
105
106
108
122
125
127
129
130
132
133
133
134
135
137
4. DETECTION METHODS 4.1 Introduction 4.2 Charged-Particle Detectors 4.2.1 Detection by Chemical Reactions 4.2.2 Detection by Direct Ionization 4.2.3 Detection by Scintillation 4.2.4 Semiconductor Detectors 4.3 Photon Detectors 4.3.1 Gas-Ionization Detectors 4.3.2 Scintillation Detectors 4.3.3 Semiconductor Detectors 4.3.4 Radiographic Films 4.3.5 Electrostatic Plates 4.4 Neutrons Detectors
139
139
142
142
144
159
165
171
173
175
182
188
188
189
Contents
xv
4.4.1 4.4.2 4.4.3 Signal 4.5.1 4.5.2 4.5.3 4.5.4 4.5.5 4.5.6 4.5.7
Gas Detectors Scintillation Detectors Other Detection Methods Processing and Analysis Basic Components Pulse-Mode Counting Current-Mode Operation Energy Spectroscopy Timing Measurements Statistics Problems in Pulse Analysis
189
204
216
218
219
224
226
227
228
232
235
5. RADIATION SAFETY 5.1 Introduction 5.2 Principles and Definitions 5.3 Principles of Radiation Protection 5.4 Monitoring and Dosimetry
243
243
244
247
248
4.5
PART II:
TECHNIQUES
253
6. TRANSMISSION METHODS 6.1 Measurement Model 6.2 Pencil-Beam Probing 6.3 Radiography 6.3.1 Film Radiography 6.3.2 Variations of Film Radiography 6.4 Tomography 6.4.1 Problem Formulation 6.4.2 Back-Projection 6.4.3 Successive Approximation 6.4.4 Modal Approximation 6.4.5 Filtered Back-Projection 6.4.6 Image Quality 6.5 Special Methods 6.5.1 Combined with Scattering 6.5.2 Region-of-Interest Imaging 6.5.3 Dual Transmission 6.5.4 Resonance Mapping 6.5.5 Mössbauer Spectrometry 6.6 Charged-Particle Transmission 6.6.1 Alpha Particles 6.6.2 Beta Particles 6.6.3 Electron Radiography
259
259
265
269
270
279
282
282
286
287
295
298
299
302
302
303
303
305
306
307
308
309
309
7. SCATTERING METHODS 7.1 Introduction 7.2 Measurement Model
311
311
312
xvi
Radiation Probing, Gauging, Imaging and Analysis
7.3
7.4 7.5
7.6 7.7
7.8 7.9 7.10
7.2.1 Model for Compton Scattering 7.2.2 Model for Neutron-Elastic Scattering Point Probing 7.3.1 Neglected Attenuation 7.3.2 Signal Modulation 7.3.3 Attenuation Averaging 7.3.4 Constant-Transmission 7.3.5 Normalized Scattering and Transmission 7.3.6 Single Low-Energy Source Transmission-Assisted 7.3.7 Two-Source Transmission-Assisted 7.3.8 Dual-Energy: Special Case 7.3.9 Dual-Energy: General Case 7.3.10 Coherent-Scatter Probing 7.3.11 Probing with Neutrons Multi-Point Probing and Analysis Scatterometry 7.5.1 Measurement Model 7.5.2 Linear Response 7.5.3 Variable Source-to-Detector Distance Method 7.5.4 Ratio Method 7.5.5 Saturated Scattering 7.5.6 Energy Spectrum 7.5.7 Combined Bulk and Probing Measurements Scatterography Reconstructed Scatter-Imaging 7.7.1 Point-by-Point Scanning 7.7.2 Integration Method 7.7.3 Nonlinear Solution 7.7.4 Coherent-Scatter Imaging X-Ray Diffraction and Refraction 7.8.1 X-Ray Diffraction 7.8.2 Refraction Neutron Diffraction Scattering of Charged-Particles 7.10.1 Scattering of Alpha-Particles 7.10.2 Scattering of Beta-Particles 7.10.3 Scattering of Ions
8. EMISSION METHODS 8.1 Gamma-Ray Emission by Neutron Activation 8.1.1 Measurement Model 8.1.2 Thermal-Neutron Activation 8.1.3 Epithermal-Neutron Activation 8.1.4 Fast-Neutron Activation 8.2 Gamma-Ray Emission by Charged-Particle Activation 8.3 Gamma-Ray Emission by Photon Activation 8.4 Gamma-Ray Emission by Positronium Decay
316
318
320
321
322
322
323
325
326
328
329
331
334
335
338
342
344
345
345
346
346
347
350
350
355
356
359
359
361
363
363
363
364
365
366
367
368
371
372
374
377
384
385
392
395
398
Contents
xvii
8.5
399
400
401
8.6
8.7
8.8
Charged-Particles Emission 8.5.1 Charged-Particle Emission by Photon Activation 8.5.2 Charged-Particles Emission by Neutron Activation 8.5.3 Charged-Particle Emission by Charged-Particle
Activation Neutron Emission 8.6.1 Neutron Emission by Gamma-Ray Activation 8.6.2 Neutron Emission by Charged-Particle Activation 8.6.3 Neutron Emission by Neutron Activation X-Ray Emission
8.7.1 Excitation by Isotopic Sources
8.7.2 X-Ray Excitation
8.7.3 Charged-Particle Excitation
Emission from Internal Sources
8.8.1 Radiotracing 8.8.2 Radioactive Materials 8.8.3 Emission Imaging 8.8.4 Gamma Cameras
9. ABSORPTION METHODS
9.1 Absorption of Charged Particles
9.2 Photon Absorption Methods
9.3 Neutron Flux Depression Method
9.4 Decay-Time of Neutrons
402
404
404
405
406
407 408 414 415 417 418 420 425 430 433 433 435 436 439
A.
Basic Units and Constants
xxvii
B.
List of Elements and Natural Isotopes
xxix
C.
Relativistic Mechanics
xxxv
D.
Quantum Mechanics D.1 Preliminaries D.2 Schrödinger Equation D.3 Concept of Cross-Section D.4 Quantum Electrodynamics
E.
Nuclear/Atomic Parameters for Compounds and Mixtures E.1 Atomic Density E.2 Electron Density E.3 Macroscopic Cross-Section E.4 Effective Mass and Atomic Numbers E.4.1 Electron-Density Based E.4.2 Reaction Cross-Section Based E.4.3 Reaction-Ratio Based
xxxix xxxix xli xlvi l liii liii liv lv lvii lvii lvii lviii
xviii
Radiation Probing, Gauging, Imaging and Analysis
F.
Effective Energy F.1 Mean Energy F.2 Most Probable Energy F.3 Cross-Section Dependent F.4 Best Match
G.
Radiation Counting Statistics G.1 Poisson Statistics G.1.1 Mean and Variance G.1.2 Population Statistics G.2 Gross/Background Count Rates G.2.1 Net Count Rate G.2.2 Number of Measurements and Counting Period G.3 Goodness of Data G.4 Current-Mode Statistics G.5 Elemental Error
References
lxi lxi lxii lxii lxii lxv lxv lxvi lxvii lxviii lxviii lxix lxx lxxii lxxv lxxvii
About the Author
clxxxvi
Application Index
clxxxix
Index
cxcix
Preface
The need for this book arose from my teaching, engineering, and research experience in the non-power aspects of nuclear technology. The lack of a comprehensive textbook in industrial applications of radiation frustrated my students, who had to resort to a multitude of textbooks and research publications to familiarize themselves with the fundamental and practical aspects of radiation technology. As an engineer, I had to acquire the design aspects of radiation devices by trial-and-error, and often by accidental reading of a precious publication. As a researcher and a supervisor of graduate students, I found that the needed literature was either hard to find, or too scattered and diverse. More than once, I discovered that what appeared to be an exciting new idea was an old concept that was tried a few decades earlier during the golden era of “Atom for Peace”. I am hoping, therefore, that this book will serve as a single comprehensive reference source in a growing field that I expect will continue to expand. This book is directed to both neophytes and experts, and is written to combine the old and the new, the basic and the advanced, the simple and the complex. It is anticipated that this book will be of help in reviving older concepts, improving and expanding existing techniques and promoting the development of new ones. Hopefully, the consolidation of this material in one book will incite wider use and application of this powerful and useful technology. Therefore, the book is intended to be a single handy source of information for students, instructors, current and potential users of radiation technology, and its design engineers and researchers. The book is divided into four parts to accommodate a wide spectrum of readers. Part I deals with the fundamental aspects of radiation sources, physics and detection, and is particularly helpful for students who are not familiar with nuclear and atomic radiation. Part II is dixix
xx
Radiation Probing, Gauging, Imaging and Analysis
rected to industrial physicists and engineers, as it provides an exposition of the different ways (techniques) by which radiation can be used to meet industrial measurement needs. Part III presents a large number of specific industrial applications. In order to assist the reader, an application index is given at the end of the book, identifying the areas in which radiation techniques are utilized. Those who would like to design a new device, or improve or alter an existing system, can refer to Part IV. This book can serve both as a reference book and as a textbook. To assist readers in searching and locating specific information, two separate indices are provided, paragraphs are given titles, and wide use is made of cross-referencing. Extensive literature is cited, and references are listed in detail. Three one-semester courses can be based on this book. The first part of the book, along with appendices C, D, E and G, can be used in an introductory course on radiation fundamentals to students with no or little background in atomic and nuclear physics. Part II, introduced by Chapter 1 and supplemented by appendix F, can serve as a course on nondestructive examination and imaging with radiation, assisted by example applications from Part III. A design course can be based on Part IV, with design projects assigned for systems described in Part III. For a set of problems and solutions, instructors can contact the author by e-mail at
[email protected]. The author welcomes any comments and suggestions for inclusion in future revisions of this book. ESAM M. A. HUSSEIN
Acknowledgments
Dr. John H. Hubbell has given me the great honor of writing the “Foreword” to the book, and provided viable comments and suggestions. Dr. Hubbell needs no introduction; researchers, practitioners and students of x- and gamma-rays are all familiar with his comprehensive work and tables on photon cross sections. The concept of this work was formulated through discussions with esteemed colleagues: Dr. Ned Kondic (formerly with the US Nuclear Regulatory Commission) in the late 1980’s, and Dr. Richard C. Lanza (Massachusetts Institute of Technology) and Prof. Nares Chankow (Chulalongkorn University, Thailand) in the nineties. Although writing this manuscript was a solo endeavor, it would not have been possible without the effort of all the authors whose work is cited in the book. Mr. P. Jacob Arsenault, Mr. Hassan A. Jama, Dr. Edward J. Waller and Dr. Ilan Yaar, of the Laboratory for Threat Material Detection at University of New Brunswick (UNB), thankfully read some chapters and provided useful suggestions. The prompt and professional response of the staff of the UNB Libraries, particularly at the Engineering Library and the Document Delivery Department, made it possible for me to readily access the based on needed literature. This book was written using platform, with WinTex 2000 as the interfacing editor. Finally a personal note to my wonderful children Mahmoud and Amina: without your love, forbearance, patience and understanding, the completion of this work would not have been possible.
xxi
This page intentionally left blank
Foreword
In browsing through a draft copy of this two-volume “how-to” desk reference on virtually all aspects of the use of photon and corpuscular radiations in the interrogation of materials and structures, I found the presentation format to be unique and useful. Although the variety and comprehensiveness is akin to a topical encyclopedia, the presentation reminded me of a thesaurus, in which the subtopics are not sequenced alphabetically, but, similar to in a thesaurus, are sequenced in a logical progression. Then, going “Roget” one better, at the end of the book are found not one, but two alphabetized indexes, first an “application index” and finally a conventional index alphabetically listing key words and their page numbers from throughout the text. In Volume One (Basics and Techniques), following a brief Chapter 1 (Introduction) surveying the unique features of radiation interrogation, often the only available tool for some NDE (nondestructive evaluation) challenges, Part I (Basics) begins this logical progression, in Chapter 2 (Radiation Types and Sources), with the definitions and nature of the various available radiations and how they can be obtained, then progressing in Chapter 3 (Modifying Physics) to the basic underlying physical processes by which these different radiations interact with atoms and with bulk materials. Part I concludes with a virtual Baedeker to the many types of radiation detectors and their underlying principles in Chapter 4 (Detection Methods) and a briefer Chapter 5 (Radiation Safety) addressing both common-sense and mandatory regulatory concerns. In Part II (Techniques) the logical topical progression continues in Chapter 6 (Transmission Methods) with a comprehensive array of topics ranging from time-honored film radiography to the mathematical intricacies of tomography to the esoteric application of Mössbauer spectrometry. Chapters 7 (Scattering Methods), 8 (Emission Methods) and xxiii
xxiv
Radiation Probing, Gauging, Imaging and Analysis
9 (Absorption Methods) similarly provide encyclopedic coverage of the available methods and techniques in each of these categories. Volume Two (Applications and Design) brings the above wealth of “why?” and “how-to” information “into the real world” beginning in Part III (Applications) with an introductory Chapter 10 (Probing, Inspection and Monitoring) with topics ranging from the function of the alpha-particle sources in most smoke detectors (such as the ones in my home) to monitoring package-filling in opaque containers. This is followed by Chapter 11 (Gauging) listing and exhaustively discussing the otherwise-difficult-or-impossible interrogations of bulk density, thickness, porosity and voidage, moisture content, fluid flow and finally dating including with carbon-14 (geological time scales), tritium (short term, such as for ground waters) and the use of thermoluminescence for TL dating (archeological time scales). Chapter 12 (Elemental and Content Analysis) continues the logical progression of subtopics including nucleus-based analysis (e.g., activation analysis), atom-based analysis (e.g., x-ray fluorescence spectroscopy, XRFS), hydrogen measurement (mostly by neutrons), and material content analysis (e.g., applications of the above-mentioned Mössbauer spectroscopy). Concluding Part III, Chapter 13 (Imaging) catalogs and provides detailed information on the many different kinds of photon radiography, on neutron and charged-particle radiography, on tomography and on imaging for material content such as in dual-energy imaging. Finally, in Part IV (Design) the author shares the experiences and knowledge accumulated in his long and distinguished teaching and research career, much of it involved in synthesizing the above material into the invention, production and putting into practice a significant fraction of the above principles and devices for carrying out NDE tasks. Thus, Chapter 14 (Performance Parameters and Design Aspects) opens Part IV with material on performance parameters, statistical optimization, design objectives, and source, technique, and detection system selections, followed by Chapter 15 (Source Modulation) with collimation considerations, filtration, and for neutrons, both moderation and multiplication. The book’s logical topical progression continues in Chapter 16 (Design Calculations) with subtopics on Monte Carlo simulations, and shielding requirements in the differing cases of x-ray machines, isotopic gamma sources, and for neutron sources. Finally, Chapter 17 (Experiments) treats the important considerations of licensing, background reduction and dynamic analysis to verify that the device will indeed perform its intended function, and the brief Chapter 18 (Finalization) discusses prototyping and intellectual property protection (trade secrets, copyright, trademarks and patents).
xxv
Volume Two closes with several appendices providing valuable information including (A) Basic Units and Constants, (B) List (alphabetically) of Elements and Natural Isotopes, (C) Relativistic Mechanics, (D) Quantum Mechanics, including the Schrödinger equation and the concept of cross-section, (E) Nuclear/Atomic Parameters for Compounds and Mixtures, (F) Effective Energy, and finally (G) Radiation Counting Statistics, including Poisson statistics, mean and variance. Following the appendices is the listing of the 1373 references including full titles and inclusive page numbers, followed in turn by the two indexes mentioned, an Application Index and a conventional Index concluding this monumental and uniquely useful “encyclopedic/thesauric” guide and companion through the thickets of radiation nondestructive probing, gauging, imaging and analysis. John H. Hubbell Ionizing Radiation Division “Emeritus” National Institute of Standards and Technology Gaithersburg, Maryland USA October 31, 2002
This page intentionally left blank
VOLUME TWO:
APPLICATIONS AND
DESIGN
This page intentionally left blank
PART III: APPLICATIONS
This page intentionally left blank
Applications
445
This Part of the book presents examples of industrial applications, classified according to the nature of their indication: probing, inspection, monitoring, gauging, elemental/composition analysis, or imaging. These examination processes, defined in chapter 1, are analogous to those performed by medical physicians when examining patients. A general practitioner “propes” a patient by verbal questioning or by examining certain localized body sites to identify any abnormalities. Since verbal interrogation of objects is not possible, probing in industrial applications refers to the process of searching (on “spot-check basis”) for changes in an object via a series of localized examinations. A physician also attempts to diagnose a disease or a condition via general “inspection” of the patient for signs and symptoms. Patients are also connected to devices to monitor their vital signs. Quantitative measurements (“gauging”) of body parameters, such as blood pressure, body temperature, heart-beat rate, etc. also assist the physician in making a diagnosis. A general practitioner, or a medical specialist, may also order blood tests or bioassay for elemental or composition “analysis”. Medical doctors also acquire radiological, ultrasonic or magnetic-resonance “images” to facilitate the diagnosis process. All these examinations are used to provide proper diagnosis, or for health-monitoring purposes. Industrial examinations aim at the same objectives, assuring the integrity, quality, or condition of an object, material, a part, a structure or a process. To aid readers in findings a particular application in a certain field, or circumstances, an application index is given at the end of the book (page ??). Some applications require a combination of a number of indications and techniques. Therefore, while Part II of this book presented mainly methods based on a single physical indication (e.g. transmission, scattering, emission or absorption), Part III presents some methods that combine more than one indication. Such combination may be required to neutralize the effect of a particular physical parameter, or may be needed to provide supplementary or confirmatory indications.
This page intentionally left blank
Chapter 10 PROBING‚ INSPECTION‚ MONITORING
Probing‚ as defined in chapter 1‚ is the investigation of a particular location. Inspection provides an overall assessment that need not be location-specific. Monitoring is a passive process of probing or inspection. The probing process is particularly helpful in detecting discontinuities caused by abnormal changes in the examined material. Unlike gauging and elemental analysis‚ probing and inspection do not necessarily provide quantified information. Therefore‚ probing and inspection can be seen as assessment tools for diagnosing the condition of an industrial object or a process. Therefore‚ the applications in this chapter are classified by the overall nature of the provided diagnostic information.
10.1.
Surface Condition
The surface condition of industrial components can be affected by deposition and erosion. For example‚ corrosion on the inside walls of pipelines and vessels can cause the condition of internal walls to deteriorate‚ creating safety and operational concerns. While deposition causes the addition of undesirable material‚ erosion results in the loss of primary material. Therefore‚ both processes change the apparent thickness and density of affected walls‚ or in other words‚ the areal density (density × thickness). This makes such measurements particularly amenable to the radiation transmission method discussed in section 6.2. Transmission Probing. With a narrow (well-collimated) beam‚ a rapid scan of a wall can be performed to detect changes in the transmission signal‚ which can be an indication of the occurrence of deposition. Gamma-radiation is particularly useful for such applications due to its high penetrability‚ ease of collimation‚ portability (due to the small size 447
448
Radiation Probing‚ Gauging‚ Imaging and Analysis
of gamma-sources) and mobility (due to the self-powered nature of isotopic sources). Example applications of gamma-transmission using a source include: the inspection of tubes in the radiant section of a cracker furnace for coke deposits‚ and the deposition of powder in the tubes of a serpentine cooler of hot powdered pigment [286]. Severe corrosion or erosion‚ that can result in wall thinning‚ can also be probed by gamma-ray transmission measurements. For example‚ the transmission of photons emitted from an source was used to “spot-check” for thinning in the tubes of heat exchangers by inserting a source in one tube and a miniature Geiger-Müller tube in an adjacent tube [286]. Scatter Probing. When accessibility to two opposite sides of an object is not possible‚ probing by radiation scattering can be employed. Also while probing with radiation-transmission provides indications along the line connecting a source to a detector‚ scattering probes a volume defined by the intersection of the fields-of-view of the source and the detector‚ as discussed in section 7.7.1. Therefore‚ by source and detector collimation‚ the inspected volume can be confined to a small zone‚ providing point-by-point scanning. On the other hand‚ relaxing the collimation of either the source or the detector or both‚ widens the size of the zone of inspection. Since gamma-rays can be readily collimated and have a good penetration depth‚ they are usually used for probing purposes‚ in the backscattering modality‚ to permit one-side inspection. For example‚ the back scattering of photons was used for detecting the corrosion of cast-iron pipelines (so-called graphitization) [287]. Steel rust buildup under insulation was also measured and quantified with backscattering of 160 kV x-rays [288]. Neutrons. Although neutrons are more difficult to collimate than gamma-rays‚ they are useful for probing hydrogenous materials. Neutron scattering is also used to avoid the collimation process required to define a transmission beam. However‚ the lack of collimation produces a larger inspection volume‚ thus neutrons are useful in probing for bulk changes. For example‚ neutron scattering was used to detect the deposition of heavy hydrocarbons at the bottom of pipelines or storage vessels‚ or the fouling of flarestack by ice deposits under severe cold-weather conditions [289]. Charged-Particle Scattering. The backscattering of low-energy (<10 keV) light-ions‚ see section 7.10.3‚ is also used to study surfacedependent phenomena‚ such as chemical catalysis‚ adhesion‚ insulators and electron emission from cathode tubes‚ as well as for studying the
Probing‚ Inspection and Monitoring
449
surface composition of alloys [240]. The backscattering of higher-energy ions‚ in particular ions‚ was used to detect surface impurities of a carbon substrate containing a surface layer of O‚ Si and Au (with 2 MeV ions )‚ silicon samples uniformly doped with As (with 1.8 MeV and to investigate a semiconductor ion-implementation process for depth of implementation‚ damage and impurities [290]. The backscattering of in the MeV range) was also used to monenergetic alpha-particles itor the surface smoothness of rough and polished silicon surfaces [291]. Radiotracer Dilution. Volume measurements‚ using the radiotracer dilution method discussed in section 11.5.8‚ can also be employed to determine the amount of material deposited at the bottom of a tank. For example‚ fluid volume measurements with a radiotracer was used to determine the overall amount of sludge deposited at the bottom of crude oil stock tanks with a tracer in the form of paradiobromobenzene diluted in the oil [277]. The thickness of deposits left over in a vacated tank can also be deduced from volume measurements of the air in the tank by using the dilution of a radiotracer gas‚ such as A similar concept was used to determine the amount of salt deposits on the inside walls of a steam superheater (hideout) by injecting a sodium carbonate solution‚ labeled with into the feed-water and scanning along the outside of the superheater using a collimated detector to determine the location of the hideout [1]. Radiotracers. Radiotracers can also be strategically implanted on surfaces to monitor their deterioration. For example‚ a dual-source method was used to monitor the wear rate of refractory linand ing in steel converters‚ and blast furnaces by embedding a small amount of the source in holes drilled in the refractory bricks‚ and monitoring the radioactivity in samples extracted from molten iron whenever the wear front reaches a source position [292]. Selective radiotracing can also be achieved by electroplating a thin radioactivated layer of material on the surface of the object. This approach has the advantage of reducing the overall amount of used radioactivity‚ while introducing only the radioactivity of choice. For example‚ in studying the corrosion of steel‚ the electroplated layer can be doped with eliminating all the other interfering radioisotopes that would result if the entire object is the low energy activated. Alternatively‚ steel can be doped with x-rays associated with its decay can be recorded on a radiographic film to provide a detailed picture of the status of corrosion. The low energy of these x-rays is advantageous in such radiograhic process as it enables localized imaging of the emission due to its limited penetrability. Such
450
Radiation Probing‚ Gauging‚ Imaging and Analysis
process was used to study the initial stages of corrosion of steel surfaces with corrosive solutions [179]. Another method of selective radiotracing was used for monitoring the deterioration of the wear of the lining of at selected points on blast furnaces by mounting small sources of the lining and monitoring the high-energy photons (1.33 and 1.17 MeV) outside of the furnace. The absence of this activity would then be indicative of sever wear conditions [179]. The high photon-energy of gammas makes it possible to detect the radioactivity from the outside of the furnace‚ while its relatively long half-life (5.27 years) allows the monitoring of lining wear for many years. However‚ the total source activity should be small‚ so that the disappearing source does not introduce a level of activity larger than that allowed in steel. Neutron Activation. The above probing methods are capable of detecting corrosion or erosion only when the amount of material loss is large enough to cause a detectable change in the material’s density or thickness. However‚ to detect a small amount of erosion‚ neutron activation (see section 8.1) can be used. By activating an entire component‚ or portion of the component‚ and monitoring the level of activity in the fluid causing erosion‚ the presence of erosion and its extent can be determined. The activation products act‚ in effect‚ as a radiotracer of the eroded material. No localized information can‚ however‚ be obtained‚ unless only a localized portion of a component is activated. In order to obtain a quantitative indication of the extent of corrosion‚ a correction needs to be made for the decay of the radiotracer‚ or alternatively‚ the measured activity should be compared to that obtained from a similar object not subjected to corrosion. Steel Corrosion/Erosion. Neutron activation is particularly useful for studying the corrosion/erosion of steel. When irradiated with thermal-neutrons‚ the iron in the steel produces (2.73 year) and (44.5 days)‚ with the half-lives given in brackets. The isotope has no gamma-emission‚ but decays by electron-capture emitting x-rays with a maximum energy of 5.19 keV. This long half-life is advantageous for long-term corrosion studies‚ but the low energy of its x-ray emission makes it necessarily to separate the wear debris from the eroding fluid‚ in order to make it possible to detect this poorly penetrating radiation [238]. Therefore‚ is the isotope that is usually monitored‚ as it emits both beta-particles (0.455‚ 0.273 keV‚ maximum) and gammaparticularly the rays (1.099‚ 1.291 MeV‚ . . . ) . The activity level of easily detectable gamma-emission‚ can be measured in the fluid causing corrosion‚ by sampling or by on-line detection of the highly penetrating
Probing‚ Inspection and Monitoring
451
gamma-rays of the resulting The half-life of is reasonably long to allow monitoring the corrosion process over a few months‚ after allowing for the decay of any short-lived isotopes that may result from any other minute elements that may be present in the steel. However‚ some long-lived isotopes may still remain in the steel producing residual activity‚ in particular (5.27 years) that results from the activation which may be present in steel. Neutron activation was used to of study the wear of piston rings in combustion engines [238]. Other applications of this steel activation process include examining the effect of various types of oils and oil additives on the corrosion/erosion process‚ and the detection of the erosion of oil risers by placing an irradiated steel coupon at the bottom of the riser and monitoring the activity in the extracted oil; and for the investigation of corrosion of heat exchangers using activated ferrules inserted into the heat exchangers tubes [277]. Wear. Another example of the use of activation tracers is in studying the wear of a cutting-tool [179]‚ made with tungsten carbide to impart hardness to the tool’s cutting edge. The neutron activating of tungsten in the tool produces a beta-emitter (626.6 keV‚ 1.3 MeV‚ maximum energy) and a gamma-emitter (685.7 keV‚ 479.55 keV) with a half-life of 23.72 h. Both isotopes are transferred to chips produced by the cutting tool. The short-range of beta-particles enables measuring the activity on one side of the chip‚ the surface sheared by the tool. Thus chips emerging on each side of the tool can be independently monitored‚ to determine the extent of the wear in each side. Gamma-emission‚ on the other hand‚ can be performed on a larger amount of chips‚ thus providing a higher count rate‚ and hence better measurement accuracy. Charged-Particle Activation. Localized probing can be achieved by charged-particle activation‚ see section 8.5‚ since a beam of chargedparticles can be focused on a certain spot of the surface. Another advantage of charged-particle activation is the poor penetrability of the charged-particles‚ which limits the activation to within a short distance beneath the surface‚ where corrosion or erosion are likely to take place anyway. This limited range of irradiation also reduces the overall radioactivity‚ by avoiding the activation of the entire object just to inspect the erosion of its surface. This process is known as thin-layer involves the activation (TLA) [277]. For steel‚ the reaction activation of the most abundant natural isotope of iron (91.72%)‚ unlike neutron activation that affects the isotope of lowest abundant isotope‚ (0.28%)‚ or (5.9%). The resulting isotope‚ has a rea-
452
Radiation Probing‚ Gauging‚ Imaging and Analysis
sonable half-life of 77.2 days with the emission of high-energy gammas‚ mainly at 846.77 keV and 1.238 MeV; it is also a positron emitter that can be monitored by the 511 keV gamma-rays associated with positron annihilation. This TLA process has been used in a number of corrosion studies involving the placement of activated coupons into flow components through specially designed gland systems [277]. Implantation of radioactive ions‚ such as and into a surface allows sensitive wear measurements by monitoring the worn away gamma activity of the implanted radioisotope [293]. Mössbauer Spectroscopy. As discussed in section 6.5.5‚ Mössbauer spectroscopy is particularly useful in iron studies‚ since natural iron contains 2.1% and the latter isotope has a strong recoilless absorption of gamma-rays at room temperature. Therefore‚ the technique was used to study corrosion [178]. The shape of the Mössbauer spectrum is affected by the presence of iron oxide and hydroxide compounds that are usually present in the corrosion products. The nature of corrosion can also be identified by this technique. For instance‚ electrochemical corrosion of steel results in the formation of which produces a characteristic peak in the Mössbauer spectrum‚ while atmospheric corrosion results in iron oxides and hydroxides that manifest themselves also as characteristic peaks [178]. Moreover‚ the particle size distribution of iron oxides and other corrosion components also affect the shape of the spectrum and can be useful in archeological‚ geological and artifact studies. Note‚ however‚ that this technique requires the extraction of a small amount of material for analysis. Positrons. Positroniums‚ see section 8.4‚ can also be used for surface analysis of porous media‚ taking advantage of the fact that positroniums tend to travel towards free surfaces. As a positron is captured by an electron in the medium‚ it gives the medium a net positive electrostatic charge‚ that repulses subsequent positrons. The positrons are consequently repulsed away from matter towards void spaces that are devoid of such repulsive force. Positrons tend to travel towards volumes free of electrons‚ such as internal cavities and free surfaces. This in turn provides a unique method for surface analysis‚ from the outside in‚ rather than from the outside to the inside as in other surface probing methods. Positrons traveling towards these void spaces will in turn pick up electrons along the way‚ forming positroniums. The lifetime (or decay constant) of positroniums is‚ therefore‚ useful for probing the surfaces of porous media [261]. Moreover‚ the intensity of measured positroniums is indicative of the total surface area.
Probing‚ Inspection and Monitoring
453
Diffraction. Neutron diffraction can also used to detect surface and near surface inclusions. A sphere of radius causes a small angular deviation of a cold neutron beam by an angle: where is the neutron wavelength [38]. Therefore‚ the diffraction angle is inversely proportional to the particle size‚ offering the possibility of detection of precipitate and corrosion products in alloys [74]. This small-angle scattering technique is used for detecting material inhomogeneity‚ such as in studying the topography of a turbine blade [294]‚ the structure of carbon-black elastomer (rubber) composites [295]‚ and the precipitation of various alloys [296‚ 297‚ 298‚ 299‚ 300]. Refraction. X-ray refraction‚ see section 7.8.2‚ is also used to characterize surfaces and interfaces in high performance ceramics‚ composites and other low density non-metallic materials down to nanometer dimensions [67]. X-ray refraction is caused by the interference‚ and subsequent phase-shift‚ by ultra-small angles‚ of x-ray scattered by objects above 100 nm in size. Therefore‚ the technique was useful in the examination of sinter glass ceramics and carbon fiber-reinforced plastic (CFPR) laminates [67]‚
Reflection. The reflection of cold neutrons (see sections 7.9 and 3.5.5.2) is useful in studying surfaces and interfaces. It has been used for investigating surface chemistry and films‚ such as in studying the adsorption of surfactants‚ polymers and fatty acids and air-liquid‚ liquid-liquid and liquid-solid interfaces [76]. In addition‚ the neutron refractive index of spin-polarized neutrons1 is sensitive to ferromagnetic materials‚ making it possible to study surface magnetism [301]. Industrial applications include [73] studying polymers and polymer blends‚ thin amorphous carbon films‚ Langmuir-Blodgett films2 and semiconductor materials and magnetic multilayers. An interesting application of neutron specular reflection includes substituting (deuterium) atoms for in atoms in has a bound scattering-length‚ of hydrogenous materials. While -3.7406 fm‚ the value of for is 6.671 fm [77]. The large and positive affects the refractive index‚ see Eq. (3.88)‚ making it value of for possible to use selective deuteration to contrast the presence of hydrogen molecules in hydrogenous materials‚ such as polymers. This feature has been used to study‚ with specular neutron reflection‚ the process of 1 The neutron has a spin of and a magnetic moment of Therefore‚ when subjected to a strong magnetic field‚ it can be polarized into a particular direction. 2 Langmuir-Blodgett films are one-molecule thick layers of liquids that float on water‚ transferred to a solid substrate by slowly passing the substrate through the air/water interface. These films may become useful in future molecular electronic and bioelectronic devices
454
Radiation Probing‚ Gauging‚ Imaging and Analysis
adsorption at the interface between a solute and a solvent‚ by substitution of in either phase. The method was used to examine the adsorption of mixed surfactants at the air-water interface [76].
10.2.
Damage and Flaw Detection
Detection of damage or a flaw in an object is the common goal of all techniques. Radiography is the most widely used radiation method in this regard‚ as discussed in section 13.1. However‚ other probing techniques are employed for this purpose; particularly when the application of radiography is not viable; e.g. when it is not possible to radiograph the entire inspected object as in the case of extended or large structures. Gamma-rays are usually employed because of their good penetrability. However‚ alpha- and beta-particles are also used. Beta-particles were utilized for the detection of faults in conventional explosive fuses using a beta-source [302]‚ while an accelerated (2 MeV) and collimated alpha-particles‚ directed close to the axis and planes of a crystal‚ were used to examine lattice damage by monitoring the backscattering of the particles. This method was also used for probing the crystal structure of a Si/SiGe superlattice and an Sb-implanted silicon sample [242]. NDE
Gamma Transmission. Gamma-ray beam transmission is useful for scanning for flaws or defects in a large object‚ such as the multi-stage process columns frequently encountered in the chemical industry. Gammatransmission can be used to monitor the performance of each stage in the column. Example applications of this approach are reported in reference [286] for the detection of tray-fouling of a fractionation column in a phenol plant that led to liquid flooding of some trays‚ and for inspecting distillation and absorption columns for loss of the demister-pad‚ foaming‚ liquid carry-over and tray flooding or damage. A flaw can also be characterized as a deviation from design dimensional tolerances. For instance‚ tight construction and operation tolerances are demanded in satellite and optical systems‚ and microelectronic‚ microsurgical and micromachinery tools. Imaging methods typically lack the spatial resolution required for such precise inspection. Reference [303] suggested the reliance on a template-machine procedure to detect if and where internal components are misaligned‚ and a modelfitting procedure to measure the deviation of out-of-line components. The procedure was demonstrated for the location of wires embedded in a regular array within a uniform fill material‚ using the transmission of xray beams along with a pattern-deviation procedure [303]. The method was devised to determine whether the sense wires in a gas-filled detector are at their intended locations (within a precision of 35 [304‚305].
Probing‚ Inspection and Monitoring
455
Photon Scattering. Gamma-ray backscattering was used to in-situ examine vessels and linings for the presence of voids‚ holes or gaps. For example‚ the method was used to examine the integrity of foamedinjected thermal insulation of pipework [287]. The same method was also used to check location of pipe joints and pipe ends in the downhole pipework associated with wells [287]. An 320 kV x-ray tube was also used to detect density variation between the cogs of synchronization rings produced by powdered metallurgy and used in the automotive industry [306]. Compton scattering was also utilized to detect flaws in near-surface cracks in steel plates under weld deposited cladding [307]‚ to detect defects in the labyrinth of coolant in metal-casted jet-engine turbine blades [308]‚ and to scan aluminum blocks for void [309]‚ Gammarays scattering is also useful in detecting debonding in composite aluminum joints [310]‚ assess impact damage in quasi-isotropic laminated composites [311]‚ and for void and density variations within food materials [312]. Using a source‚ scattering was used for the detection of corrosion pitting in underwater offshore oil risers [313]. Point probing with Compton scattering‚ discussed in section 7.3‚ was applied for detecting surface imperfections‚ up to 1.6 mm‚ in aluminum with the 90° scattering of the 662 keV photons of a source [314]. A similar technique‚ using was applied to locate groups of termite-damages sleepers during continuous scans of a railway track [315]‚ and for locating void and rebars in reinforced concrete blocks and determining their size and position [316‚ 317‚ 318‚ 319]. Scattering at 90° with a source was used to detect the presence‚ position and the amount of obstruction of paraffin (condensed petroleum) deposited in the inner walls of pipelines carrying oil in deep-water (off-shore) exploration [320]. Reference [321] reported measurements using the scattering of the 662 keV photons at different angles to detect and determine the size and location of flaws. The scattering of the 60 keV photons of an source was used for detecting hidden corrosion‚ disbonding‚ macro-cracks‚ and voids near the surface of an aircraft structure [322]. An interesting application of photon scattering is in determining the spatial orientation of fractures in formation rock by measuring the energy spectrum of a radiotracer‚ (0.889 and 1.112 keV)‚ which is significantly altered by scattering in the formation [323]. Neutrons. Neutron scattering was used for the detection of voidage in subsea grouting and cement casing and for the detection of loss of concrete lining of subsea pipes [289]. A method was proposed for measuring the local-density at a certain point in a pipe containing boiling water flow was introduced in reference [205]. The essence of the method
456
Radiation Probing‚ Gauging‚ Imaging and Analysis
is presented in section 7.3.11.1. Small-angle scattering of cold neutrons (see sections 3.5.5.2 and 7.9) is employed in the characterization of flaws that appear as small-particle inclusions‚ such as precipitates in alloys‚ impurities in silicon wafers‚ density fluctuations in polymers and pore sizes in silicas and cement [73]. Positrons. Positron trapping inside lattice defects enables the studying of lattice dislocations. Doppler-broadening of 511 keV gamma emission‚ associated with the annihilation of the positrons‚ was used to evaluate the dislocation structure of deformed thin copper sheets subjected source [324]. to positrons emitted from a Mössbauer spectrum. As discussed in section 6.5.5‚ the Mössbauer spectrum is affected by lattice defects‚ and is useful to study lattice damage in alloys. For example‚ the technique was used for studying radiation damage and aging of aluminum-iron alloys to distinguish between different phases of steel‚ such as ferromagnetic ferrite and paramagnetic austenite phases‚ or different steel alloys [178].
10.3.
Residual Stresses
Residual stresses exist in a material in the absence of an external force‚ and can be due to metal formation and fabrication processes. Residual stresses‚ or for that matter any stresses‚ are not measurable directly‚ but are determined by the corresponding material strain. The strain‚ in turn‚ affects the lattice space‚ the distance in Bragg’s law of diffraction‚ Eq. (3.66). Therefore‚ x-ray diffraction has been for many years the common method for measuring residual stresses‚ see for example references [325]‚ [326] and [327]. However‚ diffractable (cold) neutrons are more penetrating than x-rays‚ making them more appealing for use in industrial applications to measure sub-surface stresses. Neutron diffraction‚ discussed in section 3.5.5.1‚ has established itself as a mature technique for residual stress measurement‚ see reference [236]‚ Residual stress measurement has been made in many engineering components‚ such as a weldment [328]‚ pipes [329]‚ railway rails [330]‚ bent bars [331]‚ turbine components [332]‚ diamond compacts [333]‚ and metal matrix composites [334‚ 335]. Phase transformation during manufacturing affects the material’s mechanical properties and often is the cause behind the creation of residual stresses. Neutron diffraction is‚ therefore‚ used to study phase transformation‚ and its evolution with time‚ as it results in change in the crystallization pattern of materials. The technique has also been applied to study phase transformation in metal alloy composites and joints [336‚ 337‚ 338‚ 339‚ 340‚ 341‚ 342].
Probing‚ Inspection and Monitoring
10.4.
457
Flow Obstruction
Fluid flow can be obstructed by a foreign solid object inadvertently introduced into the flow stream‚ by the solidification of a flowing liquid‚ by the clustering of particulates‚ or by some other means. The direct way for detecting flow blockage is to mount a small sealed gamma-source‚ such as or and a floater that will move with the flow until it is halted by the object blocking the flow. The the position of blockage is then determined by monitoring the radiation level outside the flow container. Flow Area. Flow obstruction can also be determined by measuring the actual flow area. The flow area can be determined using a pulse of a radiotracer‚ if the inlet volumetric flow rate‚ is known and the is measured using a radiotracer‚ say by pulse time‚ as flow velocity‚ described in section 11.5.2.1‚ then flow area‚ A can be calculated as In a vessel‚ the flow volume‚ V‚ can be estimated from the time-of-travel‚ of a radiotracer pulse from the inlet to the exit of the vessel‚ as Reduction in either the value‚ A or in comparison to the nominal (design) values‚ or previously measured values‚ would then indicate the presence of a flow obstruction. Although this method does not provide a localized indication of the obstruction‚ monitoring the arrival of a radiotracer pulse between different stations along the flow can determine the extend of obstruction in the section between two consecutive stations. Also‚ an overall reduction in the flow area can indicate the need to clean-up the flow stream. This method was used to determine the extent of deposition of a polymeric by-product material in an organic chemical organic unit [277]. Thickness. The thickness measurement techniques‚ described in section 11.2‚ can also be used to detect the presence of a flow obstruction‚ by observing any increase in the measured thickness. Gamma-transmission‚ source‚ was used to detect partial blockage by powder coawith a lescence in the tubes of a serpentine cooler of hot powdered pigment by thickness measurements at various stations [286]. Gamma-transmission was also utilized for the detection of flow restrictions caused by deposition of water vapor‚ under cold weather conditions‚ in an overland pipeline carrying hydrogen gas [286]. The neutron slowing-down method for hydrogen detection‚ described in section 12.3.1‚ was used to determine the thickness of water deposition at the bottom of a tank or a pipe [287]. Since the density of hydrogen in the liquid phase is much higher than that in the gas phase‚ most of the slowing-down of neutrons would be caused by the liquid phase‚ and hence the amount of
Radiation Probing‚ Gauging‚ Imaging and Analysis
458
slowing-down‚ measured by backscattering of fast-neutrons‚ is indicative of the amount of water deposited at the bottom of a pipe or a container. Neutron slowing-down (backscattering) was also used to inspect a plant flarestack for ice blockage due to condensation of flare gases in severe cold weather conditions [289]. Reference [343] reported the use of a similar device to measure the moisture content in the medium of percolating filters used in waste-water treatment‚ to detect‚ particularly in winter‚ any material accumulation that can block the flow. Radiolabeling. Sealed radioactive sources can be used to track a moving object‚ such the ‘pigs’ used in pipelines. Cleaning or instrumentation pigs are often used in pipelines carrying gas‚ chemical and oil‚ but they can occasionally become stuck on the pipeline. Locating a stuck pig can often be a tedious and time-consuming process. However‚ if the pig is equipped with a small sealed and short-lived isotope‚ the location of the pig can be easily detected from the outside of the pipe with a radiation detector. The motion of such radioisotope-labeled pig can be also monitored a different stations along the line. The isotopes often used are (2.6 h half life‚ 847 keV main gamma) and (15 h half life‚ 1.369 MeV and 2.754 MeV main gammas). Such radioisotope-labeled pigs have been used in variety of pipelines [277].
10.5. 10.5.1.
Monitors Process Monitoring
Radiotracers are useful for monitoring and optimizing the performance of industrial processes‚ in particular mixing and fluid flow in chemical reactors‚ tanks and pipelines. Some of these applications are discussed in section 11.5‚ and some other example applications are given here. The pyrochemical process of copper production in Poland was optimized using reactor-produced radiotracers: (1.6 MeV gamma‚ 40.2 hour) and (0.5 MeV‚ 12.7 hour)‚ where the numbers in brackets refer‚ respectively‚ to the energy of the emitted gamma-rays and the half-life of the radioisotope [344]. Reference [345] analyzed the use of small quantities of ore irradiated in a reactor to study grinding systems in mills. Adsorption processes in milling plants can also be determined with radiotracers [346]. Seepage in a dike were studied using a pulse of [347]. The efficiency of sewage-treatment plants is determined using for the solid phase and or for the liquid phase [348]. The same isotopes were used to trace factory-waste causing ocean pollution‚ and to trace sand movement in river beds and and ocean floors [349]. Costal erosion was also studied using
Probing‚ Inspection and Monitoring
459
to label sand [349]. The behavior of heavy metal components in effluents from mining waste water were also examined using and radiotracers [349]. Sewage and liquid waste was investigated with tritiated water. The progress of grout‚ up the side of insert piles on offshore oil production platform‚ was monitored using in the form of glass powder suitably matched to cement [348]. The inventory (holdup) of process material (zirconium) in a solvent extraction column was determined using as a radiotracer [350]. The determination of the effectiveness dephosphorization of steel during manufacturing (to reduce its brittleness or to maintain its high phosphorus content to improve its casting properties) was done with the aid of (14 day half-life‚ 1.71 MeV pure beta-emitter) diluted into an open-hearth furnace. [351]. In blast furnaces‚ and radiotracer are used together in blast furnaces to study and measure their furnace performance [349]. The radiotracer dilution technique was a used to study the efficiency (2.69 days halfof electrolytic tanks of aluminum furnaces using life) [352]. Diffraction patterns of cold neutrons (see section 7.9) taken at different stages of the discharge of a commercial battery were utilized to study changes in its lattice structure. Neutron diffraction is also useful in the studying of liquids‚ such as lubricants and refrigerant liquids‚ and when combined with reflectometery (see section 3.5.5.2) diffraction was used to determine the effectiveness of surfactants in detergents [73]. Another interesting application is monitoring the natural process of rain formation. Cosmic-rays produce (37. 3 min‚ half- life)‚ (55 min) and (15 hr) by the spallation of argon in the atmosphere. These cosmogenic radionuclides “label” natural aerosols‚ and can be used as tracers of in-cloud scavenging. These isotopes were measured in rain water samples during storms to study the mechanisms of in-cloud precipitation formation and scavenging processes [353]. Neutron absorption is used to determine the reactive capacity (titration) of a chemical solution. If the active component in the solution contains a thermal-neutron absorbing isotope and if that component is separable from the solution in a different phase‚ the concentration of the titrand can be measured by observing its effect on the flux of thermal-neutrons. The relationship between the neutron flux and the concentration can be then used to determine the end-point of the reaction in precipitation or extraction processes. Solutions containing Cd‚ B‚ Hg‚ In and Ag can employed in this process [24].
Radiation Probing‚ Gauging‚ Imaging and Analysis
460
10.5.2.
Smoke Detectors
Ionization smoke detectors‚ widely used in homes and offices as fire alarms‚ rely on the ionization technique described in section 9.1. A small alpha-source‚ about 30 is used to ionize the air (oxygen and nitrogen) inside an ionization chamber consisting of two plates [14]. The electric charge resulting from the ionization process is collected by applying a voltage across the two plates‚ using a small battery. This current continues to flow as long as the battery is alive. When smoke particles enter the chamber they neutralize the positive charge of the ions by attaching themselves to them. This results in a decrease in the magnitude of the current flowing between the plates‚ which is sensed by the electronics of the detector‚ setting off an alarm. Once the smoke ceases to enter the chamber‚ a fresh supply of air will provide a fresh source of ions‚ and an uninterrupted electric current will flow‚ resetting the alarm. The current can also drop if the voltage supplied by the battery is below a certain preset value‚ which results in a continuous alarm until the battery is replaced. Note that in the absence of a battery‚ there will be no energy supply to power the alarm. Smoke detectors‚ based on this ionization process‚ are capable of detecting a small amount of smoke‚ such as that produced by fire flames‚ oil evaporation‚ or smoldering. It is worth mentioning that there are smoke alarms that do not use a nuclear source; the most common of which rely on light scattering. Photocell alarms (also called photoelectric detectors) are triggered by the scattering of light towards a photo-sensor located off‚ and shielded from‚ the direct path of a light source. Light can only reach the detector if a significant amount of smoke is present within the detector’s volume to scatter light towards the detector and set off an alarm. These photoelectric detectors are best suited for sensing smoky fires‚ such as that produced by a smoldering mattress [354].
10.5.3.
Radon
Radon is a noble radioactive gas‚ a daughter of radium; the latter is one of the members of the decay series of uranium‚ see section 2.4. It seeps from the ground to buildings‚ forming a potential radioactive hazard. Although radium occurs in uranium ores and certain rock types‚ its presence is more widely distributed because it forms water-soluble compounds. The presence of low levels of radon in buildings has been of some concern. The detection of radon relies on measuring the alpha-particles associated with its decay‚ or the alpha‚ beta and gamma-radiation produced by its decay products etc.). To measure radon‚
Probing‚ Inspection and Monitoring
461
a grab sample needs to be collected‚ or air has to continuously flow through a measurement chamber. Grab samples are collected in the field in a container or trapped on activated carbon3‚ then transferred to the laboratory for analysis. References [355] and [356] provide a description of sampling methods and protocols. Grab samples can be analyzed using an ionization chamber‚ with the sample transferred into the chamber with a forming gas (85% N and 15% H) through a platinum black catalyst [357]. Alternatively‚ the sample is transferred into a scintillation cell with a carrier gas. The most widely used method of detecting a low-level of radon is based on the scintillation cell of Lucas [358‚ 359]. This cell consists of a vessel with a transparent window‚ to which radon is transferred by a carrier gas. The inner walls of the cell are covered with a scintillator‚ typically ZnS(Ag) powder. The scintillation light caused by the alpha-decay of radon and its daughters is detected by a photomultiplier tube facing the window. Radon can also be measured by electrostatic collection of the chargedparticles emitted by radon and its progenies. The charged-particles can be collected on a photographic plate [360]‚ scintillator and a photomultiplier tube [361]‚ or a solid-state surface barrier or diffused junction detector [362‚ 357]. With the latter detector‚ the energy of the alphaparticle can be measured‚ allowing rapid monitoring of the 6.0 MeV and 7.7 MeV alpha-particles‚ respectively‚ of the short-lived isotopes (3.10 min‚ half-life) and half-life)‚ two daughters of radon [363]. In addition‚ measuring the 6.8 MeV alpha-particles of of (0.145 s) and the 8.8 MeV alpha-particles of the thorium decay chain‚ allows monitoring thoron in air. The device described in reference [363] has also a moisture correction sensor‚ a noble metal film whose impedance changes when water interacts with the thin film‚ along with a software correction mechanism that accounts for previous alpha particle deposition in the detector. Filter papers were also used to collect uranium particulate in air that may be present in a uranium enrichment plant under upset condition [364]. The alpha particles precipitating on such a filter paper were detected with a diffused junction silicon detector. Long-term accumulation of radon and radon progeny can be measured by passive integration of counts using nuclear-track detectors‚ such as cellulose nitrate and diglycol carbonate plastic films [357]. The density of the tracks left on such films are indicative of the number of alpha3Activated
carbon refers here to the highly adsorbent powdered or granular carbon‚ used in gas purification and chemical extraction.
462
Radiation Probing‚ Gauging‚ Imaging and Analysis
particles to which the film is exposed‚ hence to the cumulative density of radon and radon progeny. A conducting plastic chamber with an electrode at the bottom and a filtered inlet at the top is also used; the ions formed inside the chamber causes the surface voltage of the electrode to drop in proportion to the integrated radon concentration [357]. Solidstate detectors are also used to count the alpha-particles of radon and radon progeny diffused through a filter. For a period of a week or less‚ activated collectors are used‚ on which radon is adsorbed onto activated carbon. The alpha‚ beta and gamma-radiation emitted from the collectors can then be counted [357]‚ Also thermoluminescent (LTD) chips are used for measuring the alpha-particles from radon progeny introduced by an air flow into a filtered-head assembly [357]. An interesting method for determining the cumulative radon concentration over a number of years‚ hence assessing its radiological burden‚ is to measure the activity of radon daughters plated out‚ by their recoil energy‚ on hard materials such as stone or glass [365]. Radon particles and its daughters in the air tend to stick by electrostatic force to solid objects‚ such a vitreous glass. One of the radon daughters has a very short half-life and decays to This alpha-decay gives kinetic energy to causing it to recoil into the glass surface‚ to within about skin depth. The buried nuclei forms in effect an alpha-source‚ as it decays with 22.3 y half-life to The long half-life of enables the glass or stone‚ on which it is plated out‚ to act as a “memory ” of the airborne radon activity over many decades. The activity of is an indicator of the radon concentration. This alpha-decay activity can be measured using an ionization chamber or a track-etch detector [366‚ 367].
10.5.4.
Other Gases
Low-energy beta-sources‚ acting as electron sources‚ are also used in ion chambers to monitor gases entering a chamber. When a gas with high affinity to absorbing electrons‚ enters the chamber‚ it decrease the magnitude of the flowing current. This method is‚ therefore‚ used for the detection of hydrogen and carbon tetrachloride and nitro compounds (including explosives) in air‚ sulphur hexafluoride‚ solvent fume in degreasing operations‚ halogens in pesticides in and gas leaks [368]. Beta and source used in such electron-capture chambersinclude Electron-capture instruments are often connected to a gas chromatography column to measure specific components. A beta-source‚ 18.5 GBq of is used to provide in-flight warning of low rotor-blade gas pressure in a helicopter. Under normal pressure‚ the source is kept shielded. When the pressure drops‚ the source moves to an unshielded position‚
Probing‚ Inspection and Monitoring
463
allowing its beta-particles to reach a fuselage-mounted detector and provide a warning signal in the cockpit [369]. The system is known as in Flight Blade Inspection System (IBIS) [369] A smaller source (1.85 GBq of is used as an ice detector probe [369]‚ with the ice buildup blocking the passage of beta-particles to a detector. Beta-emitters‚ such as (a few to a few tens of GBq) or (about 1 GBq) are also utilized as nighttime markers of equipment (such as parachutes) or exits. [369]
10.6. 10.6.1.
Hidden Materials Industrial Materials
It is sometimes needed in industrial situations to determine whether a specific material‚ hidden from direct view‚ is in its appropriate place. The methods used for level measurement‚ see section 11.5.5‚ are also applied as fill gauges to determine whether a package of a product is filled to the appropriate level. By setting a gauge at a the required fill level‚ the gauge’s response would be abruptly perturbed when the filling material reaches a preset level. That change in response during filling can be used to signal that the package has reached the desired level‚ or when monitoring a pre-filled package to determine whether the package is under-filled. The approach was used to monitor the filling of rail tankers [287]‚ fluid (fruit juice‚ beer‚ etc.) level in cans in assembly lines [238]‚ and the filling level of soap‚ detergent and pharmaceutical packages [179]. Level gauging was also used to guard against boiling dryout in a steam generator [179]‚ and to detect failure due to slumping or collapse of catalyst-bed support in a column. Using a moving beam of well-collimated x-rays‚ individual pellets in nuclear-reactor fresh fuel elements can be inspected for position and length [7].
10.6.2.
Radioactive Materials
The presence of fissile materials in nuclear warheads‚ for treaty verification or in smuggled goods‚ can be detected by monitoring gamma-rays emitted in the energy range from 0.2 to 6.4 MeV [370]. The concept of a hodoscope‚ a battery of detectors‚ was also used to image and detect radioactive objects (such as nuclear fuel within test capsules) and monitor their movements‚ [371‚ 372]. A hodoscope detects neutrons and/or gamma-rays emitted from the material using an array of detectors‚ but can be used also to detect transmitted radiation. The process is referred to as cineradiography [373]. The applicability of this method to the counting and discrimination of nuclear warheads and the monitoring of rocket motors enclosed in their canisters is discussed in reference [374].
464
Radiation Probing‚ Gauging‚ Imaging and Analysis
Nuclear assaying is also used to provide elemental analysis of nuclear materials‚ see chapter 12. One of environmental concerns is that radioactive materials may enter the recycling process as scrap metal. Some metal processing facilities are becoming concerned with this problem and began to consider installing systems for detecting incoming scrap for radioactive materials [375]. Isotopes of concern are and [376]. These isotopes can be detected by their gamma emissions.
10.6.3.
Illicit Materials
Photon backscattering was used for detecting contraband materials‚ mainly drugs‚ hidden in spare automobile tires‚ vehicle walls‚ truck trailer walls‚ etc. [377]. The device known as the “Buster” consists (3.7 MBq) and a CdZnTe detector‚ housed in a small of a small hand-held container. The device is equipped with a microprocessor that provides both a digital display and an audio alert when the inspected object is not empty. A similar device was developed for detecting visually obscured objects hidden within extended walls [378]. Elemental and composition analysis methods are also used for detecting contraband materials‚ see chapter 12.
Chapter 11 GAUGING
Gauging aims at providing a metered (quantified) indication of a quantity of engineering interest, such as density, thickness, porosity and moisture. Fluid properties and flow measurements are also included in this category, as well as age measurement (dating) of archeological and aging objects. Usually gauging does not provide localized (probing) indications, and does not pertain to composition or elemental analysis. In addition, no imaging information are given by gauging. References [206], [379] and [380] provided a survey of radiation gauging devices in a number of industrial fields.
11.1.
Bulk Density
The macroscopic cross-section, as shown in section (3.2.3), is dependent on the material’s density, which indicates that all radiation interactions are density-dependent. However, the macroscopic crosssection also depends on the elemental composition of the material, see Eq. (E.14) in Appendix E. Therefore, for radiation interactions to provide density indications, dependence on material composition must be eliminated or compensated for. Obviously, if one is monitoring density changes of a certain material with a fixed composition, any type of radiation interaction will provide a density-dependent indication. However, if the material composition is not known, or if it changes, one has to rely on composition-independent interactions. Such interactions occur when radiation interacts with the free electrons of the matter, since then material is seen by radiation as merely a “sea” of electrons. For most materials (except hydrogen) the atomic-number, Z, is about half the mass-number, A, hence the electron density is directly proportional to the mass-density as can be deduced from Eq. (E.9). Therefore, 465
466
Radiation Probing, Gauging, Imaging and Analysis
Compton scattering of photons is well-suited for obtaining compositionindependent density measurements. Since for most materials, Compton scattering is the dominant mode of interaction at photon energies from 50 keV to 1.5 MeV, many of the radiation sources listed in section 2.10 are suited for this purpose. However, charged-particles, alpha- and betaparticles, are also useful in density measurement, particularly for small quantities of low-density materials, where the interaction rate of photons is too low to provide a sufficiently strong indication. The application of these various radiation types and interactions are discussed in the following sections.
11.1.1.
Alpha-Particle Transmission
The limited range of alpha-particles makes their use restricted to measuring the density of gases. This can be done by passing the gas between an alpha-source and a charged-particle detector, such as an ionization chamber. As the density of the gas increases, the energy of the transmitted alpha-particles decreases. The energy carried by the transmitted particles is determined by the value of their stopping power, which is a function of the material density, as discussed in section 3.3. An energysensitive detector, such as a surface-barrier detector, can be used to measure the energy of particles emitted from monoenergetic sources as those listed in Table 2.1. Since the stopping power is a linearized estimate of the average energy decrement per unit length, alpha-particles transmitted through a material do not have a monoenergetic energy, even if the source energy is monoenergetic. However, the most probable energy of the transmitted particles (i.e. that corresponding to the peak of the recorded energy distribution) can be related to the material’s density [238]. The transmitted alpha-particles can also be measured with an ionization chamber operating in the current mode, since the current is proportional to the amount of ionization, hence energy, of alpha-particles incident on the chamber (see section 4.5.3). Obviously, the thickness of the material has to be less than the particle’s range, for the detector to provide the proper response. On the other hand, the range itself can be used to measure the material’s density, since as Eq. (3.14) indicates, the range is a function of density. The range can be measured by a detector operating in the pulse mode, such as an ionization chamber, or a GeigerMüller tube, to provide a count rate. However, as Eq. (3.14) indicates, the range of an alpha-particle is proportional to the mass-number of the gas. Therefore, the density indication is dependent on the type of gas used. Another range-based method relies on the use of a thick alpha-source, which due to self-absorption will produce particles of different energies,
Gauging
467
hence different ranges [238]. When these alpha-particles pass through the inspected medium, lower energy particles will be absorbed while higher-energy ones will penetrate the medium. The number of alphaparticles transmitted will decrease with increasing material density. This thick-source concept in effect resembles a transmission mechanism similar to that attained by beta-particles or gamma-rays. All the above [179]. methods are suited only for very thin layers, about Therefore, any container material present between the alpha-source and the detector can absorb most, if not all, the source particles. These methods are not, therefore, suited for measuring the density of gases in a container, a pipe or a pressure vessel. Alpha-particles are, however, useful for measuring the density of gases, fire flames, smoke, etc..
11.1.2.
Beta-Particle Transmission
Beta-particles can also be used to measure density. Since there are more penetrating than alpha-particles, beta-radiation is useful for measuring the density of materials that are more dense than gases, and for thin objects. In the transmission modality, the intensity of betaparticles, as Eq. (3.23) shows, decreases exponentially with the material thickness and its attenuation coefficient, with the latter being density dependent as reflected by Eq. (3.24). Therefore, to perform a density measurement, the material’s size has to be kept constant. This is readily achievable in a process that produces products of a fixed thickness, such as paper products. Liquid samples should also be enclosed in thin containers, or a container equipped with a window through which betaparticles can pass. When used with materials with low atomic-number, Z, as in the case of most liquids, the attenuation-coefficient becomes independent of composition, except for the materials containing a significant amount of hydrogen. For low-Z elements, beta-particles interact primarily with the electrons of the atoms. The microscopic cross-section for such reaction, as Eq. (3.26) indicates, is a function of Z. The macroscopic cross-section, i.e. the attenuation-coefficient, becomes then dependent on where A is the mass-number of the element which scatters the beta-particles, see Eq. (E.14). Since for all elements, except hydrogen, density measurement by beta-particle transmission is reasonably independent of composition. However, in the presence of a significant amount of hydrogen, the estimated density would be overestimated, due to the increased value of from 0.5 to 1.0. If the concentration of hydrogen is known, a correction factor can be applied to the measurement. Alternatively, a calibration curve of density versus count rate can be used. One must keep in mind that the material thickness, while kept constant, should be less than
468
Radiation Probing, Gauging, Imaging and Analysis
the range of beta-particle in the inspected material at the maximum energy of the source’s particles, otherwise no beta-particles will be able to penetrate the object. Both the energy and intensity of the transmitted beta-particles are indicative of the materials attenuation effect, hence its density at a given thickness. Beta transmission is useful for liquiddensity measurement, and was used to determine the density of tobacco in cigarette packing [238].
11.1.3.
Beta-Particle Scattering
Backscattering also offers the ability to perform one-side surface and near-surface measurements. Although, as Eq. (3.28) indicates, the scattering probability of beta-particles is higher in the forward direction, the limited range of the particles does not facilitate performing forwardscatter measurements. Nevertheless, forward scattering has been used to measure the density of air at different altitudes (30 to 60 km), using a low-energy electron source incorporated into a parachute [381]. A similar measurement was reported in reference [238] using a radioisotopic source, Other backscattering density measurements include: measurement of frost density distribution on the surface of a vertical pipe, automatic monitoring of aerosol samples, and measurement of evaporation rate through turgid tobacco leaf [237].
11.1.4.
Photon-Based Methods
Density measurements are most often performed by gamma-ray transmission and scattering, not only to take advantage of the penetrability of gamma-rays, but also to obtain composition-independent density measurements as explained earlier in this section. Although x-rays are more convenient to use than gamma-rays, since their emission can be turned off, the continuous energy spectrum of x-rays contains a large portion of low-energy photons. This makes density measurements with x-rays vulnerable to photoelectric absorption, which limits the penetration depth and makes the measurements strongly dependent on chemical composition. Transmission. In a transmission arrangement, the thickness of the inspected object has to be kept fixed, or be known in advance. According to the transmission measurement model, e.g. that of Eq. (6.1), the strength of the transmission signal depends on both the macroscopic cross-section of the material (which is density dependent when Compton scattering is the dominant mode of interaction) and the thickness of the material traversed by radiation. However, the thickness of the object in transmission measurements should be equal to for optimum
Gauging
469
counting statistics, according to the optimization method discussed in section 14.2. A larger thickness will cause severe degradation of the radiation intensity, and increases the build-up effect (see section 6.1). Section 11.5.1 lists some of the applications of the technique in fluid density measurements. Other applications include the measurement of the density of cement raw meal (to determine the content of solid particles in suspension), the density of cement in rotary kilns, and the density of building materials [179]. The concentration of mud (slit) in water streams can also be measured with gamma-transmission by inserting a forked frame, holding the source on one arm and the detector on the other [179]. Using a collimated beam of photons, one can scan a vessel to determine the density distribution of its contents. This density profiling process has been used to check the packing of catalyst beds and absorption columns [286]. Gamma-transmission was also used to measure density inhomogeneities within compacted powders to monitor the packing uniformity of powder in the pharmaceutical industry [382]. The kinetics of the thermal decomposition of wood and plastic was studied by density measurements using the transmission of photons [383]. Using a number of small gamma-sources distributed across the width of a conveyor belt, multi-transmission was used to measure the density of iron ore on the belt [384]. The use of many sources minimizes the effect of the change in the photon-transmission length by lateral segregation in the ore. Weight Scale. Gamma transmission, as the transmission model of Eq. (6.1) shows, is in effect a measurement of where is the thickness of the material traversed by the radiation. Since in Compton scattering, is equal to with being a the mass-attenuation coefficient which depends on the source energy, transmission provides a measure of the so-called areal density. Now for a constant detection area, the transmission measurement becomes in effect a measure of the mass (or weight) of the material through which the transmitted radiation passes. This is the essence of radiation weight scales that are particularly useful for the nonintrusive measurement of the weight of materials on conveyor belts. The mass flow rate of the material on the belt can be easily deduced from its speed. This no-contact method of weighing can be used at high temperature, and in harsh industrial environments. Scattering. The dependency on thickness in the transmission technique can be overcome by relying instead on photon scattering. This process is schematically shown in Figure 11.1 for two scatterometer arrangements. In the first configuration, Figure 11.1a, both the source and
470
Radiation Probing, Gauging, Imaging and Analysis
the detector are located outside the inspected medium, while in configuration 11.1b, the source-detector assembly is inserted within the medium, perhaps through a guide tube. In both arrangements, the detector is shielded from direct exposure to the source radiation by a metal (usually lead) block. Although arrangement 11.1b involves intrusion through the medium, it is useful for inspecting soil and ground formations where such intrusions are tolerated. Configuration 11.1b also permits studying the change of density with depth as the device is driven deeper inside the medium. The configuration of 11.1a is particularly suited for oneside inspection, when access to two opposite sides of the object is not possible. The measurement model is the same for both configurations of Figure 11.1, since in both cases the source photons encounter a number of collisions before reaching the detector. However, in Figure 11.1a only a smaller fraction of the source particles are utilized as a significant portion of the source photons are not directed towards the medium; al-
Gauging
471
though some of the photons scattered by the walls of the shielding may reach the medium. In either case, some of the scattered photons will succeed in reaching the detector, thus providing an indication of the material density of the volume covered by the photons. The number of scattered photons depends on the macroscopic cross-section of Compton scattering, which is in turn proportional to the material’s density (as explained above). However, Compton scattering is also a removal (attenuation) process of photons, as it can scatter photons away from the detector. The two competing effects of photon scattering and removal can be represented by the following measurement model:
where S is the detector’s response, K is some system constant that incorporates the source strength, detector’s efficiency and system geometry, is the Compton scattering macroscopic cross-section of the material averaged over all scattered photons (as photons continuously lose energy according to Eq. (3.37)), L is an equivalent path-length of photons from the source to the detector, is the material density and is the mass attenuation-coefficient of the medium. The value of L depends on the source-to-detector distance, while the value of is a function of the source energy. The estimated value of according to the model of Eq. (11.1) is the average density of the region covered by the scattered photons. This averaging effect is caused by the many collision encountered by the photons over a wide area before reaching the detector. Therefore, if the medium is not homogeneous, the estimated density will correspond to that of an equivalent homogeneous medium. The model of Eq. (11.1) indicates that the detector response will increase with increasing density, until the density is sufficiently high for the attenuation effect to dominate the scattering effect, then the detectors counts will decrease with increasing density. Therefore, the detector response reaches a maximum value at some density, before decreasing with with density. This maximum density is a function of L and the latter depending on the source energy. Accordingly, for the same detector response, two estimates of the density can be obtained; one from the ascending portion of the response and the other from the descending side. However, to avoid ambiguity, the device can be designed to function on one side of the response curve of Eq. (11.1) by choosing a proper source energy and source–to-detector distance. Devices for measuring the soil density are normally designed to function in the descending side of the response curve. The model of Eq. (11.1), by setting the Compton scattering cross-section equal to the attenuation coefficient (in the argument of the exponential term), ascertains that the Compton effect is the
472
Radiation Probing, Gauging, Imaging and Analysis
dominant process of removing photons. However, as photons lose energy, the photoelectric effect becomes prominent. Since the cross-section of the photoelectric effect is strongly dependent on the atomic-number, see Eq. (3.30), the device can become sensitive to changes in the material composition. This dependence can, however, be diminished by electronically discriminating against low-energy photons, see section 4.5. Applications of this density measurement with photon scattering include the measurement of the density of soil [179, 215, 238]. Compton scattering density measurements was also performed on concrete structures [385, 386]. Reference [387] suggested the use of the backscattering of 50 kV x-rays to rapidly measure the density of an organic material on a steel conveyor belt. The scattering of gamma-rays emitted from a was used to measure the density of coal seams in neutron source water-filled boreholes. An interesting early application of this scattering technique was in the determination of the water content in snow on the ground by measuring its density [179]. Reference [287] reported an application involving the use of the backscattering of photons to detect the extent of a form of corrosion of cast-iron pipes called “graphitization”. This process results when the liquid or the gas in the pipe dissolves iron from the metal cast, allowing the liquid or the gas to diffuse through the pipe walls, reducing in effect the density of the wall. Backscattering is particularly suited for this application, not only because it allows the inspection of buried pipes, by having only access to one side of the pipe, but also because the amount of density change is too small to allow inspection with a transmission technique (even if access to two opposite sides of the pipe was possible). Although reference [287] reported the use of the technique for inspecting pipes carrying river water, to cool a power plant, the technique can also be applied for the inspection of gas pipelines. Backscattering of photons was also used for measuring the density of a layer, or thin-lift, of known and constant thickness on a planar substrate, such as in the repaving of roadways and bridges. Two measurements are required, one before the layer is applied, and one after [388]. A backscattering gauge was also developed for monitoring and control of material conditions in a steel sintering plant by measuring the density of plant material [389]. In coal exploration, gamma-ray scattering is used to detect the position of the interface between coal and underlying rock strata [390]. Also, since ash content is directly related to the mineral content, which in turn is related to density, gamma-scattering can be used an indicator of the ash content [390]. In the oil industry gamma-scattering is used to measure the density, of a formation, which along the speed of sound in the formation gives
Gauging
473
useful seismic information [40]. An x-ray generator (an electron linear accelerator) was considered to provide higher source intensity and improve the detection sensitivity [391, 392, 393, 394]. In well-logging (or wireline logging)1 gamma-scattering is used to determine the density of various layers of the strata as the probe is lowered deep into the ground. Note that the speed, of a longitudinal wave of sound in a where Y is the modulus of elasticity of the solid material is equal to material. Therefore, by measuring with gamma backscattering and with an acoustic method, the value of Y can be determined, indicating the strength of the structure. Measurements are performed in a well-log ) and with a tool containing a gamma-source (typically or one or two gamma-ray scintillation detectors, with the source separated from the detector by some distance. To ensure that the detectors are monitoring Compton scattering, the electronics are set to discriminate against low-energy photons, where the photoelectric effect is dominant. The device is then driven through the borehole and butted against its wall by a spring to reduce the effect of the mud-cake (the residue of drilling mud deposited on the borehole wall) on the measurements. The mud-cake will scatter some photons towards the detector, while preventing other from reaching the detector. However, by viewing the problem of density formation as a problem of two unknowns: the bulk density of and the change in recorded density due to the mudthe formation, then using two measurements, a solution can be found for cake, the two unknowns, thus correcting for the effect of the mud-cake. Two scattering detectors are used for this purpose, one near the source and the second away from the source [40]. Each detector in effect views a different region of the formation and the mud-cake, thus providing two independent measurements. Calibration curves are then employed to determine both and using the count rate provided by the two detectors. Dual-Energy. The dual-energy Compton scattering method, discussed in section 12.2.2.5, was used for the determination of density of a substance enclosed within another substance [395], using the 41 keV source. The method relies and 100 keV photons emitted from a on estimating in advance effective values for the total cross-section of
1 Well-logging, or wireline logging, is the term used in oil exploration to record a log, i.e. a graph of the response versus depth of an instrument (also called a sonde) driven down a hole (called a borehole) at a certain logging speed, to measure some property of the formation through which the borehole is drilled. Measurements can also be performed while drilling by equipping sections of the drillpipe with proper instruments.
Radiation Probing, Gauging, Imaging and Analysis
474
the two substances (as a weighted value at the incident and scattering energies), and by knowing the total distance of travel of radiation from the source to the detector. The problem then has only three unknowns, the density of the central material (causing the scattering), and the total distances traveled by radiation in each of the two material. The three problem unknowns can then be determined from the two scattering measurements, in addition to the fact that the total distance traveled by singly-scattered radiation remains constant and is known in advance. The method was investigated for measuring the electron densities of and consolidated volumes of potassium hydrogen phosphate calcium chloride polystyrene and plexiglass immersed in water. Although the method was developed for use in the human body (e.g. bone surrounded by tissue), the method can be used in industrial applications to measure the density and size of material inclusion within an otherwise uniform medium. Positron Annihilation. Another interesting method suitable for measuring low-density materials, 10 to (such as foam materials, polystyrene and polyurethane) relies on measuring, in coincidence, with two opposite detectors, the two (511 keV) photons produced by the annihilation of a positron. A fixed positron source inserted into the investigated medium can be used for this purpose. Reference [396] reported the use of a (3.08 h half-life, 1.044 MeV maximum energy) source. The measured count rate, recorded at a distance from the source, was experimentally shown to follow the relationship:
where K is a system constant that depends on the strength of the is a factor that depends positron source and the detector efficiency, on the relative size of one detector with respect to the other, hence size and type of the detectors, while and are parameters that describe the attenuation of the count rate with distance from the source.
11.2.
Thickness
Thickness measurements by nuclear methods are useful when noncontact gauging is to be performed within a short time, or when direct access to the material is not possible, such as in measuring the thickness of deposits on the inner walls of a tube. The transmission techniques described in section 11.1.1 for beta-particles and gamma-rays can be used for this purpose, since for a given material and radiation type (i.e. constant total cross-section, transmission will provide the value of the thickness, see Eq. (6.1). The poor penetrability of alpha-particles
Gauging
475
limits their use to thin and light materials. X-ray fluoroscopic emissions and neutrons can also be employed in thickness measurements. A number of standards have been developed for thickness measurement with radiation [397, 398]. The following sections discuss some of the thickness measurement applications classified by the technique used.
11.2.1.
Charged Particles
Alpha Particles. The limited penetration of alpha-particles makes them suitable for measuring the thickness of thin and/or light materials, such as liquid and gas films, gases, papers, plastic coating on paper, ions) etc. The absorption and backscattering of alpha-particles was used for measuring the thickness of aluminum, nickel, silver and gold films in the thickness range of to [399]. Rutherford backscattering was shown to provide higher accuracy than optical methods, in addition to providing indications of film contamination (change in composition). The aperture area of optical diaphragms was also measured by alpha-particle scattering [400].
Beta Particles. The sightly higher penetrability of beta-particles, than most other charged-particles, makes them suitable for measuring thicker or more dense materials, such as paper and plastic sheets and metallic foils, rubberized fabric and coatings on metallic sheets [238, 179]. The transmission of beta-particles not only offers more penetration, but its thickness indications are easier to interpret as they follow empirically the exponential relationship of Eq. (3.23). Beta-particle transmission, as described in section 11.1.2, can used for measuring the thickness of sheet materials of areal densities of typically about This corresponds to a steel sheet of about 0.4 mm in thickness, or an aluminum sheet of 1 mm thick. Table 11.1 provides a guide for selecting a beta-source for a given areal density range. Reference [401] described a method for measuring the thickness, and uniformity, of large area sheets of paper, aluminum, nickel and gold, using a source. An on-line gauge used in the cellulose and paper industry employed a double-transmission technique for improved sensitivity, by magnetically deflecting, by 180°, transmitted particles back through the object [402]. A system employing was also used to monitor and control the production of plastic foils in the 20 to thickness range. The backscattering of beta-particles is most useful in measuring sheet and coating thickness. The detector’s response can be expressed by Eq. (7.72). Thickness gauging with scattered beta-particles is very common; in spite of the fact that the measurements are affected by many parameters. The scattering response is affected by changes in the source-
476
Radiation Probing, Gauging, Imaging and Analysis
to-object and object-to-detector distances, geometry of object, dirt deposits, vibrations, etc. The short range of beta-particles makes them vulnerable to such changes, and may necessitate frequent calibration and or adjustment. Applications of beta-particle scattering include: monitoring of thin oil films in compressors, measurement of thin organic films on optical lenses, and measuring thickness of tin and zinc coatings on steel, of precious metals coatings on printed circuitry and of jewelry and mirror coatings [287]. Reference [237] reported the use of thickness gauging with scattered beta-particles for measuring the thickness of high quality polymer sheets for the predictability and control of layflatness in calendering, on-line measurement of thin organic films on metallic aluminum and steel substrates; and thickness measurement of glass and aluminum containers. An interesting application of beta scattering for thickness measurements is in measuring the thickness, hence strength, of an intact eggshell to determine the effect of pesticides on bird population [24]; a thinner eggshell is indicative of loss of calcium that may be due to exposure to pesticides. Reference [403] provides recommendations for the calibration of commercial backscatter instruments, the choice of electronic equipment for representation of the results, and the operation of the beta detector.
11.2.2.
Photon Transmission
Gamma transmission is also useful in thickness measurements, using the same concept discussed in section 11.1.4, provided that the material density is known. The ability of gamma-rays to penetrate deep into matter makes the technique useful for measuring a large thickness in a dense material. However, the measurement of thickness, as in the case with i the total where density measurements, is optimum when cross-section of the material at the source’s photon energy and is the
Gauging
477
thickness, see section 14.2. This limitation ensures good utilization of the source photons, by allowing a significant amount of photons (about 13.5% of those incident on the object) to reach the detector, while reducing the effect of buildup (photon scattering) on the detector [238]. source, which emits photons with an average enFor example, for a ergy of about 1.25 MeV, is equal to in steel of density of [19], allowing the measurement of a sheet of steel 47.83 mm thick. One can still apply the technique outside this optimum range, and substitute for the lost sensitivity by increasing the source strength and/or the counting time. Therefore, is used for steel thickness up and are applied to steel thickness of up to 150 mm, while to 100 mm and 10 mm, respectively [286]. Gamma-transmission was used for measuring the thickness of hot rolled strip and plate steel [286]. Reference [286] describes a device for pipe-thickness scanning consisting of a source and detector mounted on the opposite ends of an adjustable metal yoke that can be clamped gauge on the outside surface of a pipe or a vessel. An was used to monitor and control the production of rubber strips, from 3 to 40 mm in thickness [404]. Tube thinning produced by corrosion of the tubes of a heat-exchanger, inspected during plant shutdown, was also measured with gamma transmission [286]. A small gamma-source for thin tubes and for thick tubes) is inserted in one tube, while a miniature Geiger-Müller tube is introduced simultaneously in an adjacent tube so that it resides at a location opposite to that of the source. The intensity of the transmitted signal should remain constant unless corrosion thinning occurs in the tube walls between the source and detector. This method is reported to be sensitive to as low as 0.1 mm tube thinning. Although non-radiation techniques such as eddy current and ultrasonics are also used in such applications, radiation transmission offers measurements that are easy to interpret, suitable for use with any type of alloy composition, not dependent on the surface condition and can be rapidly implemented. Reference [157] described a gamma-transmission thickness measurement device that was used to determine the dimensions, shape and weight per unit length, of steel products, such as beams, rails, tubes, etc. The system consists of a triangle-like arrangement, at each edge of which a fan-shaped gamma source is located. Along each side of the triangle a bank of collimated scintillator detectors is positioned to measure the photons transmitted through an object positioned at the center of the triangle. The intensity of the transmitted radiation is used to measure the thickness of the product along the source-detector trajectory. The shape of the inspected object is determined from the dis-
478
Radiation Probing, Gauging, Imaging and Analysis
tribution of the transmitted photons. The product is then moved along an axis normal to the plane of the measurement triangle to provide three-dimensional information, from which the weight per unit length can be determined. This three-beam arrangement can be viewed as a limited-projection tomography. Buildup. To overcome the effect of scattering (buildup) in transmission measurements of thick and dense objects, such as steel plates, reference [405] suggested using a total cross-section in the transmission model of Eq. (6.1) that is a function of the thickness so that:
where is the material’s total cross-section and and are positive constants that are determined experimentally. For a small thickness, in Eq. (11.3) approaches as would be expected since the buildup effect becomes negligible. As the thickness increases, the value of decreases, to compensate for the increased contribution of scattering. Divergence. In applying an exponential transmission model, such as that of Eq. (6.1), the source-to-detector distance should be kept constant, since the model ignores the divergence of the source radiation. However, divergence is inevitable even if the source is well-collimated, see section 15.1. By maintaining the source-to-detector distance constant, the amount of this divergence is kept unchanged at a fixed value. This may be difficult to attain in practice, as it is the case when scanning an irregular object. Reference [406] suggested the use of a dual-beam method, with each beam having a different energy [406]. The ratio of the two transmission measurements then eliminates the divergence effect, if the two sources utilize the same collimator. Reference [406] used (60 keV) and (81 keV) sources to measure the thickness profile of medieval weapons (sword and helmet).
11.2.3.
Photon Scattering
The photon-scattering technique described in section 11.1.4 can also be used in thickness measurements. Backscattering is particularly useful for objects that are too thick to be measured by charged-particles, but are too thin to significantly affect the intensity of transmitted photons. By choosing a source with an energy at which Compton scattering is the dominant mode of interaction in the object material, the measurement model of Eq. (7.10) becomes applicable. With a small thickness (less than one mean-free-path of the source photons) the contribution
Gauging
479
of multiple scattering becomes negligible, further validating the use of the single-scattering model of Eq. (7.10). For a certain material and a given photon source energy, and with all other source-detector parameters fixed, the intensity of the scattered radiation will depend on the thickness, via the exponential attenuation factors and of Eqs. (7.2) As the thickness increases, and (7.7), and the scattering volume, increases, but both and decrease, due to the increased attenuation. The increase in being linear, will originally dominate until the thickness becomes large enough for the attenuation effect to begin to decrease the scattering response. Since this technique is aimed at nottoo-thick objects, the source energy can be chosen, for the maximum thickness expected, so that the scattering response coincides with the ascending portion of the response curve. This simplifies the response of the device and ensures the determination of a unique thickness value system based on this principle was for a recorded measurement. A designed for measuring steel-tube wall-thickness [238]. Reference [287] reported the use of the technique to determine the thickness of a spherical steel vessel, which was thought, after ultrasonic inspection, to have developed apparent thinning, due to the presence of harmless surface interfaces created by impurities or internal crystal boundaries. Such interference would reflect prematurely ultrasonic waves, before they reach the other end of the tube wall, thus giving the mistaken impression of a reduced thickness. Photons, on the other hand, are not affected by such interfaces, and therefore give accurate determination of the thickness. Scattering measurements also enable the inspection of one side of the vessel, unlike transmission measurements which would cover both sides of the vessel. The scattering of 22 keV x-rays at an angle of 135°, showed a nearly linear relationship with wood density, over a wide range of wood densities [407]. The thickness of glass and aluminum containers was measured with backscattering using (136 keV) and (60 keV) and x-rays [408], while reference [409] reported the use of gamma scattering for concrete, carbon blocks and wood thickness-measurement. Compton scattering was also used for coal mining to provide information on the correspondence of strata in regions adjacent to boreholes and to indicate the thickness of particular coal strata and the presence of “dirt bands” within the strata [390].
11.2.4.
X-ray Emission
The X-ray fluoroscopic emission method (discussed in section 8.7) is also useful in thickness measurements. Since these emissions are isotropic, they can be monitored from the same side as the source, which makes the method particularly suited for measuring objects that are only
480
Radiation Probing, Gauging, Imaging and Analysis
accessible from one side. Since x-ray fluoroscopy (XRF) requires the excitation of an atomic shell, its emission probability is highest in elements with many occupied electron orbits and high electron density, i.e. in metals. Therefore, this thickness measurement method is particularly useful for use with thin metal layers and metal coatings. XRF emission is acclaimed to be the most accurate and reliable technique to measure thin metal coatings [410]. Table 8.14 lists some of the isotopic sources that can be used for this purpose, along with the elements that they can excite. The characteristic energy of the emitted photons is used to identify the excited element, hence one can distinguish between emissions from say a coating material and a substrate. By monitoring emitted photons at these energies, one can also discriminate against source radiation that may reach the detector, as well as background radiation. The intensity of emitted x-rays can be estimated using Eq. (8.12), leading to the measurement model:
where C is the recorded count rate at the XRF energy, K is a system constant that incorporates the source intensity, system geometry and and are the attenuation-coefficients of the indetection efficiency, cident and emitted radiation, respectively, is the XRF emission total cross-section (including the emission yield), and is the thickness of the material emitting the fluorescent x-rays. The two exponential terms in Eq. (11.4) account, respectively, for the attenuation of the incident and emitted radiation before and after reaching a depth within the inspected layer, while is the probability of XRF emission within a around Emissions, if they exist, from other surrounding distance material such the substrate under a coating, does not affect the count rate, since it is recorded at an energy different from that of the material of interest. The model of Eq. (11.4), when plotted, will show an exponential increase in the count rate with thickness, to a saturation value of beyond which the count rate will be insensitive to changes in thickness. Therefore, thickness measurements have to be performed at some count rate below the saturation value. The “saturation” thickness can be taken to be equal to i.e. the thickness at which the count rate reaches about 86% of the saturation count rate. Given that metals have large total cross-sections at the low energies of excitation and emission (see Table 8.13), the measurable thickness with XRF is quite small. Also instead of monitoring the K x-rays, one can monitor the lower energy L x-rays, which further reduces the value of enabling the measurement of even smaller thickness. This method is suited for
Gauging
481
measuring thin coatings in the order of micrometers. Therefore, this method was used for measuring the thickness of chromium plates deposited on nickel and tin, cadmium and silver plates [411]. Standards for coating thickness measurement with this method are available [397], while reference [412] discusses the practicality of these standards. Double Transmission. Another approach is to monitor x-ray emissions at the XRF energies of the substrate. One would then have in effect a double-transmission system: source radiation transmitted through the coating layer, with a total cross-section of and XRF radiation transmitted in its way out through the same layer, with a transmission coefficient The measurement model for this double-transmission system would then be: where C is the recorded count rate at the energy of the substrate, is a system constant, and is the coating thickness. The model of Eq. (11.5) assumes that the substrate is a reasonably thick layer so that the XRF emission from the substrate is saturated (reached its maximum value). This method is advantageous only if the energy of XRF emission from the substrate has a lower energy than that of the coating, enabling the measurement of smaller thickness of the coating material. For example, while the K x-ray energy of tin (Sn) is 29.2 keV, that for iron (Fe) is only 7.1 keV [268]. Therefore, for tin coatings on steel, it is advantageous to use the double transmission method over the method depicted by Eq. (11.4) for measuring thin layers [411]. Note that the latter method could be used for even a smaller thickness by monitoring the L x-ray emissions from Sn, of about 4 keV, but the yield is also lower. Ratio Method. Reference [413] reported the use of the ratio between the intensities of various x-ray fluorescence lines for measuring coating thickness, using one of three options: (1) the ratio between the characteristic x-ray lines of the base (substrate); (2) the ratio between the characteristic x-ray lines of the coating; or (3) the ratio between Xradiation emitted by the base and that emitted by the coating. The last method was found to provide the best resolution for Au on Ag, while the first method may be advantageous when x-rays are difficult to detect, as in the case of a light-element coating. X-ray emission induced by a 280 keV proton beam was used for film thickness measurement of very thin layers (5 to 500 nm thick of copper platinum carbon and silicon [414]). The thicknesses of single, double, and triple layered films of Cu, Bi and Au on Mylar substrates were mea-
482
Radiation Probing, Gauging, Imaging and Analysis
sured using the excitations produced by a source, to a minimum thickness of 70 nm for Cu and Bi and 40 nm for Au [415]. The attenuation of x-ray fluorescence was used to measure the thickness of layers of varnish (10 to on the inside and outside of aluminum tubes. Reference [416] described a simple and quick method for measuring thin metallic layers using a source and a proportional counter.
11.2.5.
Neutrons
Neutron absorption techniques (see chapter 9) are useful for measuring the thickness of materials of high absorption cross-section. In addition to the elements of high thermal-neutron absorption cross sections, elements that exhibit cross-section resonances in the epi-cadmium energy range of 0.5 to 2.5 eV, or so, can also be examined with neutron absorption. The suitable elements are indium, hafnium, gold, gadolinium, cadmium, europium, dysprosium, cobalt, manganese, rhodium, samarium, silver, uranium and tantalum [24]. Silver, gold, rhodium and cadmium are elements often used for coating materials. The thickness of such coatings can be determined by measuring their effect on the absorption of thermal or epi-cadmium neutrons, using any of the techniques described in chapter 9. A neutron backscattering technique, employing a moderated source and a detector, was proposed for measuring changes in wall thickness due to corrosion and scale deposits in desalination and chemical plants, for up to 50 mm in iron and more than 100 mm in concrete, aluminum and glass [417].
11.2.6.
Composition-Independent
Thickness measurement with radiation is inevitably compositiondependent, since it is affected by the material cross-section of the radiation used. When composition variations in the measured material are expected, the use of more than one measurement technique becomes necessary, in order to compensate for, or eliminate, composition dependence. An additional measurement can be obtained by using another source energy, or a different type of radiation, that interacts with the inspected material in a manner different from that of the first source. In this regard, reference [418] reported the use of a beta-source, and a or an x-ray machine, to monitor varilow-energy photon source, ation in the composition of aluminum strips, up to 2 mm in thickness. An alternative method to providing composition-independent thickness measurement is to employ two different types of indications for the same source, such as transmission and scattering. This approach was used for
Gauging
483
providing thickness measurement of aluminum strips that are independent of the alloy composition [419, 420].
11.3.
Porosity and Voidage
Porosity and Permeability. Pores are hollow passages into a solid material, or among solid particulates, that allow the passage of a fluid. Porosity and permeability are the terms used to describe the amount of available void space that permit liquids or gases to pass through. Unlike isolated void space, porosity can be measured by detecting the fluid passing through the pores. For instance, in rocks porosity can be indicated by the presence of water or other hydrogenous materials (such as oil). Therefore, porosity in well-logging is determined by measuring the hydrogen content, typically using neutron slowing-down, as explained in section 12.3. Reference [421] describes some of the basic physics of borehole logging using neutron slowing-down, for both static and dynamic measurements, while reference [422] suggested combining the measurement of thermalized neutrons with that of epithermal neutrons and prompt gamma-rays resulting from neutron activation, to improve sensitivity to porosity variation and minimize dependence on salinity. Porosity of closed structures and rock cavities can also be measured with the aid of a gaseous radiotracer, such as by measuring the amount of gas that can seep through the structure from one side to another. This method was used for determining the permeability of rock strata surrounding a hole in the center of a mountain, intended for use as a site for a rock vessel reactor [179], Note that being a rare gas, krypton is chemically inert and thus has low toxicity and low contamination risk. The permeability of rocks can also be estimated in well-logging by measuring the natural radioactivity in the formation. Clay and shale show a higher level of natural activity than sandstone and limestone, and such indication can be correlated to permeability [40, 179, 323]. Voidage. While porosity usually refers to interconnected void that allows fluid flow, voidage is any form of empty (or almost empty) space within a medium. In general, voidage represents air pockets that reduce the overall density of a material. Therefore, the void content of a certain material can be deduced by comparing its measured density (using any of the techniques of section 11.1) to the material’s nominal density. Voidage can also be viewed as a reduction in the thickness of the material that attenuates radiation. Accordingly, the thickness measurement techniques described in section 11.2 can also be used to measure the thickness of the “filling” (non-void) material, and compare the measured thickness to the apparent (geometric) thickness. For ex-
484
Radiation Probing, Gauging, Imaging and Analysis
ample, gamma-ray transmission is applied to detect cavities in a rolled steel, voids between stress-ducts in concrete structures and voids in refractory lining of pipes [286]. Voidage is also measured by gamma-ray backscattering, when access to two opposite sides of the object is not possible, or when the amount of voidage is not large enough to affect a transmission signal. For example, the backscattering of photons from an source was used for the detection of voidage in foamed thermal insulation of pipes, introduced by injecting a foam mixture into a gap created around the pipe by an aluminum alloy cladding [286]. Vapor in steam and gases in multi-phase flows are also seen as void, due to their low density. Methods for measuring the void volume-fraction are discussed in section 11.5.11 and 11.5.12. A substantial proportion of free volume (void) is present in polymers, either as holes, a few tens of a nanometer in size, or larger voids due to packing irregularities [423]. The amount of free volume per gram determines the polymer’s viscosity, hence voidage is an important parameter that affects the utilization of polymers in industrial applications. The characterization of such microscopic holes is very difficult, except with positron annihilation. Positrons and in turn positroniums, see section 8.4, are trapped in holes and cavities. The lifetime of positroniums in a hole depends on the size of the hole; the larger the size, the longer the lifetime of the positronium, due to the increased isolation from the adjacent medium. Therefore, the average size of a free hole (radius if assumed spherical) can be determined from the lifetime (or decay constant) of the orthopositroniums, see section 8.4. This method was used for determining the hole size in epoxy polymers and zeolites [261]. The total fraction of the free volume can be determined from the intensity of the decayed positroniums [424]. Moreover, the shape of the decay curve is also indicative of the distribution of the free volume, which can change with pressure and temperature.
11.4.
Water (Moisture) Content
Water as moisture and wetness appears in many industrial situations. Moisture, defined here as the content of diffused or condensed liquid water, is a quantity of interest in may industrial fields. Knowing the amount of moisture in soil is important in agriculture, soil mechanics and hydrology. It is also often required to measure the moisture content of coke and sinter mix (fed to blast furnaces), clay, concrete (particularly ready-mix concrete), textiles, wool, cotton, plastics, aerosols, gases, wood chips, wood fuel, and other materials, used for manufacturing or processing industrial products. The hydrogen content is an indicator of the moisture content, when water is the dominant source of hydrogen in
Gauging
485
the material. The methods discussed in section 12.3 can then be used for measuring the moisture content. However, by using hydrogen as an indicator of moisture content, no distinction is made between free water that seeps into the material as a moisture, and bound water that is an inherent constituent of the material. Bound water is present in the crystal lattice of some minerals (such as carnallite, limonite gypsum and potash), and within the plate structure of clays [40]. If a significant amount of hydrogen is present in a form other than water, it then becomes necessary to account for the non-water hydrogen by knowing the material composition, either in advance or by some other means. In addition, strong neutron absorbers, such as chlorine, lithium and boron, will also affect the response of moisture content devices based on neutron slowing-down, as they obviously affect the neutron population and its distribution within the inspected medium. In a thin medium, a beta-particle gauge can be used, due to the increase in the attenuation coefficient of beta-particles with the atomic-to-mass number ratio, which is equal to about half for most materials and is equal to unity for hydrogen. Beta-particles were used for measuring the surface wetness of a leaf [425], the frost density distribution on the surface of a vertical pipe [426], and variations in the moisture content of a paper web [179]. Interestingly, it is reported that the intensity of natural background gamma-rays (assumed to be terrestrial gamma-rays) can be related to the moisture content of shallow soil to within ±20% accuracy [427] Reference [289] reports an interesting application of neutron gauging for the detection of water flooding into tabular-tube supports of offshore platforms. Water seepage into these tubes is usually an indication of structure flaws. The neutron-moderation method for hydrogen detection, described in section 12.3, is particularly suited for this purpose, since neutron slowing-down is hardly affected by metallic materials that are often found in these structures. Therefore, a neutron backscattering device was used for this purpose. When the tube is empty, neutron scattering would arise only from the surrounding water. This background signal can be reduced by surrounding the detector surface (except for the portion facing the tube) with cadmium to cut-off the slow-neutron scattered by the surrounding water. Then, when the tube is flooded (filled with water), a high count rate would be observed. Hydrogen as an indicator of moisture water is employed in irrigation management using the neutron slowing-down method [343, 428]. The neutron source, usually Am/Be, is positioned on the surface of the soil, while a thermal-neutron detector is lowered into a hole in the soil. The measured count rate is calibrated against the volume concentration of “free water”; with the latter defined as the water released by drying
486
Radiation Probing, Gauging, Imaging and Analysis
the soil at 105°C. The relationship between the count rate and the water content is typically linear, but the sensitivity of the device, i.e. the slope of the linear curve, depends on the type of soil. The same detectorinsertion approach is used for in-situ measurement of moisture content of wood chips in piles or hoppers, and for determining the moisture in coal and coke [343]. The ratio of the intensity of the 2.223 MeV gamma-rays resulting from the capture of thermal-neutrons by hydrogen and the thermal neutron flux produced by slowing-down fast-neutrons were shown to provide good accuracy and low sensitivity to the elemental composition for measuring the hydrogen content of coal [429]. The moisture content of moulding sands in foundries was also measured with this method, under the harsh working conditions of such operations (high temperature, dust and vibrations) [24], The same reference also reported the use of the technique to control the moisture content in high grade-glasswork to an accuracy of about ±0.1 % at 3 to 5 weight percent concentration, scintillator. A portable gauge using an Am/Be source and a was also designed for the detection and measurement of water infiltration (to as low as in reinforced concrete flat roofs using the backscattering of moderated neutrons [430]. Neutron backscattering was also used to determine the moisture content of iron ore samples to within 0.5% moisture [431]. A system for measuring the moisture content in an underground nuclear waste storage facility is described in reference [432]. The system employed a source and two detectors, one located near the source and the other far from the detector, with the three housed in a core penetrameter that can be inserted into a waste tank. The ratio of the readings of the two detectors (Near/Far) was shown to be indicative of the hydrogen content in the waste. By surrounding the detectors with a thin layer of cadmium, the near-to-far ratio was less sensitive to the presence of neutron absorbing materials, since epi-cadmium (above 0.5 eV in energy) neutrons are not as vulnerable to neutron absorption as thermal-neutrons. The detectors were also shown to be quite stable under the high temperature and the high radiation levels encountered in waste tanks. Inserting a detector within a medium provides a very effective indication, since every neutron that reaches the detector would have traveled through the interrogated medium. However, when it not possible to insert an instrument within the inspected object, the detector can be located outside the object. Then, provisions must be made to minimize the direct exposure of the detector to the source neutrons, see section 17.3.3. Nevertheless, surface-mounted gauges, that include both the source and detector, have been used for measuring the moisture content in concrete
Gauging
487
and building materials, in thermal-insulation layers, in iron ore samples, in live trees, agriculture products, fireclay, plaster and lactose used in pharmaceutical products [24]. Neutron moderation was used for measuring the moisture content of blast-furnace coke [433], and the consistency and fiber density of pulpwood-water slurries [434]. Although neutron scattering and the associated slowing-down process is the most common method of moisture detection, its sphere of influence (sensitive volume) is limited to a small region around the detector’s site, due to the low total cross-section of slow-neutrons. Transmission of fast-neutrons overcomes this difficulty, since the intensity of the transmitted neutrons is also affected by the number of slowed-down neutrons, scattered and removed from the incident beam. The difficulty of fast-neutron transmission is in obtaining a well-collimated beam of fast-neutrons, since the collimation process performed with the help of a moderating material also slows-down the fast-neutrons. Collimation is essential for applying the simple exponential measurement model manifested by Eq. (6.2). Moreover, fast-neutron detectors are less efficient than slow-neutron detectors, as discussed in section 4.4. Nevertheless, neutron transmission was used for measuring, on a conveyor belt, the moisture content in a sinter mix of constant thickness (120 mm) of materials used in iron making [433]. As the measurement model of Eq. (6.2) shows, the transmission measurement is also affected by the material density, via the macroscopic cross-section and the thickness of the material traversed by the neutron beam. In materials of variable density and thickness, a concurrent gamma-transmission measurement can be used to correct for these changes, see section 6.5.3. This so called Neugat (neutron-gamma transmission) method was used for measuring the moisture content in soil and marine sediment, in coke emerging from a weight hopper in iron-processing plants or transported in a conveyor belt, in wood chips and in wheat [343]. Another interesting application of neutron slowing-down is in the measurement of snow accumulation by monitoring the slowing-down of atmospheric neutrons, produced by cosmic-ray protons. Although this neutron flux is quite low, it is measurable, (about over land [343]. The presence of snow (a neutron moderating material) increases the count rate of thermal-neutrons in a detector located at the snow level, due to the scattering and subsequent slowing-down of the atmospheric neutrons. Via the same process, the snow layer will shield a detector located at the ground surface from the atmospheric neutrons. Then, the combined relative change of the thermal flux at two locations, one below the snow layer and the other above it, becomes indicative of the thickness of the snow layer in between the two locations. The ratio
488
Radiation Probing, Gauging, Imaging and Analysis
is indicative of the thickness of the snow layer [343]: where C refers to the count rate of the detector above the snow layer, G, to that below the snow layer and the subscripted variables refer to the count rate recorded at the same detector locations in the absence of the snow. This measurement method is useful for remote monitoring of snow covers in isolated areas, with the recorded count rate continually transmitted via satellite or radio signals. It is also worth noting that reference [435] pointed out that rainfall results in a significant reduction in the number of atmospheric neutrons recorded from 3 m above the ground to 0.40 m underground. It was also noticed that the recovery time to the initial neutron flux, before rainfall, depended on the soil’s moisture content, offering the possibility of remotely and passively measuring soil moisture following rainfall with neutron counting. Gamma-transmission was also used for measuring the moisture content in soil samples. Water resides in the void (pores) of the soil, and the maximum amount of water in soil is that which fills the pores, i.e. saturates the soil. The saturation level, S, is defined as the volume of water, to the volume of void in the soil, that is:
where M and V refer, respectively, to mass and volume, is the void volume fraction, is the nominal density of water and is the “apparent” (or bulk) density of water in soil. The latter density is what determines the degree of attenuation of a gamma-ray beam passing through a sample, which in accordance to the transmission model of Eq. (6.1), and making use of Eq. (11.6), can be written as:
where I is the intensity of the beam passing through a sample of thickness is the total cross-section per unit mass of water, is the intensity of the beam when it passes through a dry sample, i.e. at S = 0, and is a calibration constant that depends on the source energy, soil type and porosity and the sample thickness. Gamma-transmission is particularly suited for measuring the moisture content in a limited volume of soil and in soil columns [436, 437], a process that is difficult to accomplish with neutrons due to the small amount of moderating material. To overcome the dependency of measurements
Gauging
489
on the compactness of the soil sample, a dual-energy gamma-ray transmission method was suggested for measuring the water content in soil tubes [438]. For a sample of constant thickness, the transmission of highsource) provides an indication of energy photons (662 keV from a the mass-density (as Compton scattering dominates), while the transmission of low-energy photons (60 keV from is sensitive to the atomic-number due to the photoelectric effect. The effect of density on the transmission of low-energy photons can then be accounted for using the transmission of high-energy photons, resulting in an indication that is a function of the composition of the soil/water mixture. Thus for a given soil type, and a known transmission thickness, the water content can be estimated. A method for measuring moisture in radioactive wastes was proposed in reference [439], using the scattering of neutrons from a source (Am/Be, inserted into the medium. Subsequent thermalization Pu/Be or causes the activation of a copper probe. Counting the gamma-rays emitted from activated (12.7 h half-life) becomes then indicative of the amount of neutron slowing-down, hence hydrogen content. Copper replaces conventional neutron detectors that are overwhelmed by the high gamma-radiation of the nuclear waste. Such measurements are not, however, real-time, since the activated copper needs to be removed from the inspected medium to measure its activation.
11.5.
Measurements in Fluid Flow
Fluids in the form of liquids, molten materials, and gases of various compounds are encountered in many industrial applications. Measurement of parameters pertaining to the physical properties of these liquids and gases are often required. Although many conventional techniques are available for performing such measurements, most of these methods are intrusive, require direct contact with the flow container, or cannot function in the presence of thick metallic walls associated with highpressure systems. Radiation techniques overcome these difficulties by enabling the performance of non-contact measurements. Thus radiation methods can be the only viable choice for measurements at high pressure and temperature and in harsh industrial environments; although in large vessels it may be necessary to introduce the source, and/or the detector, within the vessel, if the vessel diameter is too large to allow for external inspection. This section shows that many fluid-related properties are measured with radiation methods.
Radiation Probing, Gauging, Imaging and Analysis
490
11.5.1.
Density
The density of a fluid or a gas is a fundamental quantity in fluid and gas dynamics. The density of a fluid varies with temperature and pressure, or when phase transformation (e.g. from liquid to gas) occurs. The density measurement techniques discussed in section 11.1 can be applied to fluids. However, measurements under flow conditions often require rapid sampling, necessitating sometimes the use of detectors that can function in the current mode (see section 4.5) when conventional pulsecounting methods are not statistically adequate. The penetrability of gamma-rays and the direct relationship between their Compton scattering cross-section and density makes them particularly useful for measuring fluids in pipes and vessels. Therefore, the gamma-transmission method is used for measuring the density of a fluid in a pipe, usually by transmitting source photons across the cross-section of the pipe, in a device known as the gamma densitometer [440]. The source and detector fields-of-view should cover the entire section of the pipe to provide a representative indication of the bulk density of the fluid in the pipe. Reference [441] also proposed the use of a wide (strip) source that covers the entire cross-sectional area of the pipe, along with a set of collimated detectors that measure the transmitted radiation. By collimating the source into a pencil beam, and confining the detector field-of-view to receive this beam upon transmission through a pipe or a vessel (so that the contribution of scattered photons is minimized), one can scan the flow to obtain a profile of the density distribution in the vessel. Reference [179] reported the use of gamma-transmission in the petroleum refining industry to distinguish between various grades of oil; determine the concentration of dissolved gases in liquid; detect condensation in different parts of steam boiler; and to measure the particle concentration in fluidized beds, and the concentration of sodium hydroxide in caustic-soda evaporators. Gamma-transmission is also used for the detection, by density changes, of frothing and foaming, liquidliquid interfaces, bubbling and gas slugs [286]. The same reference describes in some detail a nonintrusive radiation transmission method for scanning distillation columns (which can vary in diameter from 0.3 to 8 m) to measure the density profile of a column along its length, using or sources. Such measurements are useful for ensuring that the column’s metallic components are in their proper place and none is missing, for the detection of undesirable foaming or flooding, and for overall confirmation that the liquid and vapor phases in the columns are distributed as required by design. When access to two opposite sides of a pipe or a vessel is not available, and it is not permitted to insert a source or a detector inside the fluid
Gauging
491
enclosure, gamma-scattering measurements become handy. For example, the scattering of high-energy photons, extracted from a reactor was used for dynamic density measurement of boiling water [442], while in situ density measurement in aqueous solutions was performed by the gamma backscattering method [443]. Thermal-expansion coefficient. Density measurements can be used to determine the thermal-expansion coefficient, defined as:
where V is the volume of a material of mass T is its temperature and is its density. According to Eq. (11.8), by measuring the density of material at different temperatures, the value of can be obtained. This method was used to measure the thermal-expansion coefficient for a light oil contained in a vessel at high pressure (13.8 MPa), with the aid of a gamma densitometer [444].
11.5.2.
Flow-Rate by Radiotracers
The mass flow-rate, W, is defined as:
where refers to mass, to time, to density, A to flow area, to distance along flow direction, is mean fluid velocity, and is the volumetric flow rate. The expression of Eq. (11.9) assumes that the liquid is moving in one direction at a constant speed and density, at least within the measurement time. With the flow assumed to be constant and equal to the area of the duct within which a fluid moves, the mass-flow measurement is reduced to a measurement of density and velocity. While density measurements can be conducted as discussed in section 11.5.1, velocity measurement are more difficult to perform non-intrusively. However, radiotracers can be used for this purpose. Although radiotracer-based flow measurements are more accurate than other methods, their non-continuous nature prevents their use in routine measurements. Therefore, they are mainly used to verify or calibrate measurements obtained with conventional methods, or when it is not possible to employ a conventional device. 11.5.2.1 Pulse Timing The most straightforward method for flow measurement involves the injection of a pulse (over a short period of time) of a suitable radioactive
492
Radiation Probing, Gauging, Imaging and Analysis
material at some point in the system, and monitoring the arrival of radioactivity at two different positions separated by some distance downstream from the injection point. As the radiotracer arrives at the first point of detection, the amount of radioactivity emitted from the tracer will rise as the radiotracer approaches the detector, reaching a maximum, at time when the radioactive material is closest to the detector, then it would fall as the radioactivity travels. The same trend will develop at the second detector, but at some later time, Then, the mean velocity, is simply estimated as: Alternatively, one detector can be used, if the pulse injection time is measured. This simple method is suited for turbulent flows, where good mixing of the injected tracer occurs. The detector has also to be placed at some distance from the injection point to allow the mixing process to fully develop. This method is known as the pulse velocity, or peak-to-peak, method. Reference [445] reported the use of this pulse-timing method for measuring the flow rate in feed-water lines of boilers flow to the absorption unit of an adipic-acid2 plant sulfuric acid flow in the reticulation system of an alkalination plant natural gas flow and in flow gas distribution systems the rain pipelines dioisotope employed is given in brackets. Radiotracers were used for measuring the inlet and outlet flows in pulp and paper mills [179].
11.5.2.2
Total Count
Instead of timing the signal, the detector integrated count rate can be used as flow-rate indicator. A detector monitors radiation emitted from a certain volume, V, of the flow. The counts registered by the detector depend on the time spent by the radiotracer within the volume V, assuming that the radiotracer is detected after it has been fully mixed to a certain concentration level. The time, the radiotracer spends that within V is in turn inversely proportional to the fluid’s velocity is, the slower the flow, the more chance the radiotracer has to register a count in the detector. Therefore, the inverse of the time-integrated count rate of the detector becomes indicative of the flow rate. Since no timing measurement is required, this total count method does not require a sharp pulse, as in the case of the peak-to-peak method. The gas flow-rate in chemical processes and steam flow as tritiated water) were measured by the total-count method.
2
Adipic acid,
is a crystal used in the manufacturing of nylon.
Gauging
11.5.2.3
493
Constant-Rate Injection
The pulsing approach can be replaced altogether by continuous injection of the radiotracer. If a radiotracer of a known specific activity (activity per unit volume of the flow material), is introduced into the flow system, through an injection line, at a known volumetric flow rate of it will generate activity at a rate of If there is no leak in the system, there is no reason for the activity to change. However, when the radiotracer enters the system, it will be transported at a volumetric flow rate of where is the flow rate of the fluid. Then, the specific activity of the radiotracer will be reduced to Since and are controlled and known, by measuring the specific activity in the flow material, one can determine its volumetric flow rate, The specific activity of the flow material can be determined by withdrawing a sample, of a certain volume, at a position sufficiently away from the point of injection, and recording the count rate it produces in a detector. Many samples can be analyzed, either to improve the accuracy of measurements, or to detect changes in the flow rate. The volumetric flow rate, is related to the mass Thus, if the fluid’s density, flow rate, W, by the density, is known, or is measured separately, then, W can be determined from This is easier than calculating W using the fluid velocity, since the latter requires knowing the flow area, A, as Eq. (11.9) indicates. Therefore, this so-called constant-rate injection method is suited for applications in which the flow area changes, or is not known. The method is, therefore, suitable for use in containers of irregular geometries, and in open channels and rivers (where a sample can be withdrawn easily for counting) [445]. Under steady state conditions, the radiotracer can be injected only over a limited amount of time, and the method becomes known as the dilution method. Using the dilution method was used to study the fate of contaminants released into the flooded Magela Creek system in Northern Territory of Australia as a consequence of nearby uranium mining operations [446]. The method was also used to measure the efficiency of aluminum-reduction furnaces using [352, 447], and for measuring the flow in water turbines [179]. The constant-rate injection method was also utilized for measuring the water flow rate during the acceptance and performance testing of cooling water pumps in fossil-fired power plants and in the turbine of hydroelectric power stations [348]. The constant-rate injection method was applied to the measurement of organic liquid flowing from a stock tank to calibrate an orifice meter as para-dibromobenzene); effluent discharge from chemical plants to the environment; and gas flow rate in chemical processes [445].
494
Radiation Probing, Gauging, Imaging and Analysis
The method was also utilized in measuring the flow of cooling water in oil refineries [179]
11.5.3.
Gas Flow-Rate by Ionization
The ionization of a gas can be used to measure its flow rate, with the aid of an ionization chamber, see section 9.1. The essence of the method is that a moving gas will remove some of the gas molecules from the domain of the applied electric field, hence reduce the magnitude of the ionization current. The higher the rate of removal, the less time the gas atoms will be exposed to radiation, the lower the ionization current. Therefore, the ionization current decreases as the flow rate increases. However, if the flow rate is too high, so that most of the ions are carried away, or if number of gas atoms ionized is not sufficient, or if the ionization process is too slow to be affected by the movement of the gas, then it may be difficult to obtain measurable indications of the flow rate. The flow rate of the gas must be within an order of magnitude of the velocity of the ions in the electric field [24]; though the latter can be controlled by the magnitude of the applied field. Note, however, that the pressure and temperature of the gas must also be taken into account, as they affect the ionization current, since they affect the gas density, hence the ionization cross-section, defined in Eq. (9.1). Flow rate measurements in pipes can be accomplished by mounting a source of alpha-particles on the inner surface of the tube, held at a positive voltage, with an ammeter connected by wire coaxially mounted on the outside surface of the tube [24]. Alternatively, a source of beta-particles (which is more penetrating than an alpha-particle source) can be mounted on the outside of the pipe, and pulsed with the aid of a movable shutter. The arrival of the ionized atoms at two different stations downstream of the beta-particle source can be monitored with the aid of two pairs of electrodes mounted inside the pipe, with each pair recording a current pulse. The time delay between these two pulses is inversely proportional to the flow rate of the gas [24].
11.5.4.
Flow-Rate by Pulsed-Neutron Activation
The flow rate of a fluid can be measured by activating the fluid material with a short pulse of neutrons and detecting the gamma radiation emitted from the activated nuclei at a known distance downstream from the activation point. Pulsed 14 MeV neutrons are suited for this purpose, as they produce in oxygen-containing fluids (such as water) high-energy photons by the reaction: with the product nuclei decaying with a 7.32 s half-life and giving rise to 6.13 MeV gammas. For
Gauging
495
molten fluids containing sodium, 14 MeV neutrons induce the reaction with the latter nucleus emitting 1.633 MeV gamma as it decays with a 11.0 s half-life. The number of photons detected, C, within a period of time, is related to the flow rate by the relationship:
where is the number per unit time of fluid nuclei of velocity activated by the source neutrons at is the decay-constant of the activated element, is the probability that the nuclei of the activated element will decay before reaching the detection volume, and P is the probability that the decaying nuclei are present in the detection volume within the counting period, If the detection volume has a thickness along the direction of the flow velocity, then P can be estimated as:
The measured velocity can then be related to the average velocity, hence the flow rate. References [158] and [448] provide more comprehensive measurement modeling and analysis of this flow measurement method, while references [449] and [450] discuss the application of this method for flow measurement in sodium and water. The applicability of the technique to two-phase flow measurements is addressed in references [451], [452] and [453]. The technique has also been used to monitor and measure the water flow behind and in wellbore casings, for mechanicalintegrity testing of water injection and disposal wells [454]. Pulsed photon activation, using high-intensity gamma-rays produced from the bremsstrahlung target of an electron linear accelerator [455] can also be used in flow measurements. Photons with an energy greater than 15.7 MeV result in the reaction which can be used to tag oxygen in a water flow. The decay of (122 half-life) produces a positron, which annihilates generating two 511 keV photons, emitted in opposite directions. Monitoring the arrival time of these annihilation photons downstream of the activation location enables the calculation of the speed, hence flow rate, of the water (or boiling water).
11.5.5.
Level Measurement
The measurement of fluid level in a tank or a container is one of the most common applications of radiation gauging. Although other conventional methods of level measurement are available, the non-contact and continuous nature of radiation methods makes them attractive for
496
Radiation Probing, Gauging, Imaging and Analysis
on-line and harsh-environment applications. A number of measurement arrangements are possible, as schematically shown in Figure 11.2. Each of these configurations is discussed below. 11.5.5.1
Photon Transmission
Gamma-ray transmission is the method commonly used in level measurements, since they have the ability to penetrate large tanks, and because it is easy to interpret the indications of the transmission modality. The most common setup is the transverse arrangement (beam parallel to fluid level, Figure 11.2.a), which involves sending a radiation beam horizontally from one side of the tank and receiving the radiation with a detector on the other side of the tank, at the same elevation. If radiation passes through the air (or gas-layer, if any) on the top of the fluid in the tank, a strong transmission measurement would be recorded, otherwise the detector would register a lower count rate as it passes through the fluid. The source-detector assembly can be located at one position for level monitoring purposes, i.e. to determine whether fluid level is above or below a certain value. The transverse transmission measurement is essentially a binary measurement that distinguishes between high or low intensities. Therefore, the count rate obtained from a simple detector, such as Geiger-Müller tube, can be used, which reduces the cost of the device due to the simplicity of the associated electronics. However, if the fluid level is to be monitored at various levels across the tank, many transmission measurements have to be taken at different elevations. Then, the elevation at which the count rate increases to the level corresponding to an empty space determines the level of the fluid in the tank. This is a tedious process, if performed with a one source-detector set. Not only because many measurements need to be taken, but also because proper alignment of the source and the detector, to be at the same elevation, can be difficult, particularly for level measurement in large tanks. A motorized mechanism can be used to move both the source and detector to the different measurement stations, while maintaining their alignment. Alternatively, many source/detector assemblies can be employed. However, if a fan-shaped beam is used, with a width it will cover a larger area of the tank. By blocking the top half angle and placing a long detector, or a set of of the fan beam (from 0 to detectors, opposite to this source, on the other side of tank, the transmission of the other half of the beam (from 0 to can be monitored. Then, the fluid level can be monitored simultaneously over a wider range of levels. Typically the angle is less than 20° [286], since for fan beams wider than this, the distance of travel across the tank, along with the
Gauging
497
498
Radiation Probing, Gauging, Imaging and Analysis
increased divergence of the source photons (see section 3.6.2), would weaken significantly the strength of the transmitted signal. Transverse transmission is used for level measurement in chemical plant vessels [286]; for example to determine the catalyst bed-level in the columns of amines and methanol plants, and to measure the rate of catalyst attrition (to determine whether recharging or regeneration of the catalyst is required). To avoid the complications of the transverse-transmission technique, longitudinal (beam normal to fluid level, Figure 11.2.b) transmission can be performed, say by placing the source at the bottom of the tank (if possible) and the detector at its top. In this arrangement, the source and detector can be fixed in place, ensuring proper alignment, and the liquid level can be continuously monitored. However, the response of the detector will change as the fluid level varies, as demonstrated schematically in Figure 11.2.b. This requires the intensity of the transmitted radiation to be quantified with the aid of a measurement model. Due to the large amount of fluid usually involved in such measurement, the simple model of transmission represented by Eq. (6.1) is not usually adequate, since it is inevitable that scattered radiation would reach the detector. Therefore, the model of Eq. (6.5), which includes the buildup factor should be applied for the longitudinal-transmission technique. Alternatively, a calibration curve for the change of the transmission intensity with fluid level should be established. The build-up factor itself also requires calibration measurements. Reference [456] suggested the use of the attenuation of the intensity of cosmic rays (above 3 MeV to eliminate gamma-rays from natural environmental nuclides) to measure levels in very large storage tanks, and to determine the height of snow piles. 11.5.5.2 Photon Scattering Gamma-ray backscattering can also be used for level measurement. This offers a one-side measurement that does not require access to two opposite sides of the container, and does not require a very strict alignment process. The device can also be manufactured in a single package containing the source and the detector, for portability and mobility. The alignment in scattering is not that crucial, since as schematically demonstrated in Figure 11.2.c, the detector measures radiation scattered by the fluid, when present, at various locations. The response of the detector will tend to be constant as long as its field-of-view within the tank is completely filled with liquid. As the source approaches a location near the top level of the fluid, some of the source photons will escape prior to encountering any scattering with liquid, the detector’s field-o-view will also be partially occupied by the air (or gas if present) on top of
Gauging
499
the fluid. Of course, as the source is moved away into positions corresponding to the voided portion of the tank, the detector response will drop quickly to the background level, since it will only receive photons scattered by the wall of the tank and the surrounding shielding, and if close to the liquid top, by radiation reflected by the liquid. Due to this gradual change in response, exact determination of the liquid level may not be possible, but a good indication can be obtained with prior calibration of the device. For non-hydrogenous liquids, such as chlorine gamma-ray backscattering is used for or titanium tetrachloride level measurement, as an alternative to gamma-ray transmission [287]. Gamma-ray backscattering was also used to monitor on-line continuous flow of the feed to a blast furnace [179]. Although this gamma-ray backscattering method is quite attractive for the reasons discussed above, it has a fundamental drawback that limits it applicability: scattering emerges from a small volume (domain of influence) around the detector. This limited inspection-volume is attributed to the fact that photons scatter in all directions, and the scattered photons have a lower energy than the source radiation, as such very few photons scattered deep inside the container will reach the detector. While this limited domain-of-influence makes the response independent of the vessel diameter, if the latter is larger than the domain of influence, it has some important implications. First, the monitored volume may not be representative of the overall situation in the container, if the liquid distribution is not uniform, e.g. if a flow vortex or an obstruction in the medium elevates the liquid in the vicinity of the device. Secondly, if the container has a thick metallic wall, the wall’s contribution can be quite significant compared to that of the liquid, because of the high density, hence high scattering probability of metals. For instance, for source, 622 keV photons, a steel wall (density of a 10 mm thick would represent the equivalent of 78.6 mm of liquid water at atmospheric pressure density). This obviously reduces the sensitivity of the device. Thermal insulation materials, if present, can also occupy a significant portion of the inspection volume. Although it has a low density, thermal insulation displaces, in effect, the device’s domain of influence. For a 662 keV photons, gamma-ray backscattering becomes practically “blind” to level changes at steel thickness of 32 mm, or a thermal insulation 50 mm thick [287]. Elevating the photon energy, say by using a source, increases the size of the domain of influence of the device, but this comes at the expense of increased divergence of the scattered photons due to increased distance from the collisions sites to the detector (see section 3.6.2). Another problem with using a source with higher energy is the increased shielding requirement
500
Radiation Probing, Gauging, Imaging and Analysis
for both biological purposes and for protecting the detector from direct exposure to the source photons, which increases the size and weight of the device. Neutron backscattering is a more practical way to overcoming the limitations of gamma-ray backscattering, in hydrogenous liquids. 11.5.5.3
Neutron Scattering
Utilizing a neutron source in the system configuration of Figure 11.2.c enables the performance of level measurements using backscattering with all the advantages mentioned in section 11.5.5.2. In addition, neutrons can accommodate thicker metallic walls; up to 130 mm of steel under ideal conditions and practically up to 40 mm thickness [287]. This neutron technique is mainly used with hydrogenous liquids, since it functions by monitoring the slowing-down of fast-neutrons. Therefore, a fastneutron source, such as or Am/Be, is used in conjunction with a thermal-neutron detector or While the hydrogen in the liquid effectively slows-down the neutrons, see section 3.5, the metal hardly affects the energy of the neutrons. Theretofore, the metallic walls of the container have very small effect on the detected neutrons, except that a thick wall effectively occupies a larger portion of the device’s domain of influence, reducing its sensitivity to the presence of the liquid as mentioned in section 11.5.5.2. The presence of a thick thermal-insulation material has also a similar effect. In addition, hydrogen that may be present in the texture of the insulating material, or when the material is wet, can affect the response of the device by giving a false appearance of the presence of liquid. Applications of this technique include measuring the liquid level of liquid ammonia in railway tankers and other vessels carrying hazardous hydrogenous materials; the liquid level in the shell-side of a heat exchanger; and the liquid level in the downcomers of a distillation column [287], particularly during accident emergencies. A continuous neutron backscattering level gauge was also developed for the level measurement of hydrogenous, as well as non-hydrogenous materials (for solid and liquid levels) [431]. In the latter case, although no-significant number of neutrons would be slowed-down, a good number of neutrons would scatter back as fast neutrons. When the device faces a voided space, the response of the detector would decrease due to the lack of a scattering medium. A neutron-scattering device in a nonhydrogenous medium would, therefore, function as a density indicator, in the same fashion as a gamma-ray scattering system. 11.5.5.4
Radioactive Media
For radioactive material in a vessel (such as fission products in solution), a level gauge consisting only of a radiation detector can be used.
Gauging
501
Reference [457] indicated that the detector can be located at the top of the container, but in containers of small diameter-to-height ratio, the detector should be located within the tank along its axis. In very large diameter-to-height ratio containers, it is advantageous to locate an additional detector along its off-center axis. Reactor Level. The liquid level in the pressure vessel of a nuclear reactor (liquid cooled) can also be measured by the effect of radiation on detectors embedded within the vessel, or even detectors located outside the reactor core. Reference [458] demonstrated that the response of a cadmium-covered gas-filled fission chamber located at different elevations outside the reactor core is sensitive to voiding in the upper portion of a pressurized-water reactor. The number of fastneutrons escaping the reactor tend to increase as the water level in the core decreases, due to the lower density of the vapor. Fast-neutrons have a higher probability of leaking from the reactor, than thermal neutrons, and thus provide a better indication of the condition of the core. The response of in-core neutron detectors in water-cooled reactors also changes significantly when the detectors cease to be covered with liquid water, due to the corresponding decrease in neutron collisions, hence neutron flux, around the detector. Therefore, such in-core detectors can be used to determine the liquid level in a reactor vessel during a loss-of-coolant accident [459]. Gamma-radiation inside a reactor core also deposits energy in metals, causing their temperature to increase. This allows the use of gamma-ray calorimetry to monitor conditions within the reactor. The calorimeter is simply a steel rod, equipped with thermocouples along its axis. When the rod is inserted inside a reactor vessel, a certain temperature profile will be established along the rod axis, as long as the rod is fully immersed in water. The temperature profile is recorded electronically. When part of the rod becomes uncovered, i.e. exposed to steam, the temperature of the corresponding thermocouples will increase due to the poor cooling by the steam. The position of these thermocouples will then be indicative of the liquid level [460]. Note, however, a mixture of steam and water provides good cooling, lowering the temperature of the corresponding thermocouples. A similar concept used a heated junction thermocouple, adjacent to another unheated junction, with the two enclosed in a common sheath [461]. The two thermocouples are enclosed in the same sheath and electrically connected to record their temperature difference, which is indicative of the heat-transfer coefficient of the surrounding medium. In the presence of liquid, the good heat-transfer between the two junctions will keep their temperature difference small. On the other
502
Radiation Probing, Gauging, Imaging and Analysis
hand, when the sensor becomes uncovered, the temperature difference will increase due to the poor heat-transfer of steam. In addition, the temperature of the unheated thermocouple acts as a calorimeter.
11.5.6.
Liquid-Liquid Interface
Liquids interface with each other in vessels, atop each another, or in pipelines one following the other. When the two interfacing liquids differ significantly in density, one of the density measuring techniques described in section 11.1 can be used to detect their interface. Gamma-radiation is usually employed because of its high penetrability. The gamma-transmission method for density determination, see section 11.1.4, can be employed for this purpose. Transmission measurements can be performed intrusively, if the size of the flow-container and its wall thickness and density are not prohibitively large to the extent that they suppress the passage of a detectable amount of radiation within a reasonable counting time. This method was employed for detecting the interface between a sweeping liquid propane and a denser mixture of carbon products in a 100 mm pipeline, to enable segregation of the two products at the end of the line [286]. Alternatively, in a large vessel, the source, or both the source and detector, can be gradually inserted inside the vessel. This internal gamma-transmission setup was used for monitoring the density profiles of packed-bed reactors (with an inserted source) and for the measurement of silt densities of lakes and rivers (with an inserted fork carrying the source and the detector at opposite ends) [286]. Gamma-ray backscattering was also employed in well logging, where a compact device containing the source and the detector (separated by a shield) is driven up and down inside a well to locate the interface between liquids in underground storage cavities containing various materials [287]. The gamma source (83.79 d half-life, and 0.889 and 1.120 MeV), activated in a nuclear reactor in the form of scandium oxide, is usually preferred for use in well-logging. The relatively high energy of the source gives a reasonably large distance of penetration, so that it provides a density averaged over a reasonable volume, while its short-half life is a safety feature; in the event that the source is lost within the well. When the two interfacing liquids are similar in density, as may be the case with hydrocarbon products, the change in their elemental content can be used to distinguish between the two liquids. The hydrogencontent measuring methods discussed in section 12.3 can be used for this purpose. For example, the interface between an aqueous (mainly water) and organic water in an effluent holding tank in a plastics manufacturing plant was measured with the aid of the neutron backscattering method
Gauging
503
described in section 12.3.1 [289]. The same reference reported the use of the technique to detect the interface between oil and water in a separator vessel, employing an array of neutron sources and detectors spanning a height of about 450 mm. Gamma-ray transmission, with a source, was also applied to the interzone-layer separating two fluids in an extraction tower, by taken advantage of the density gradient between the two separated fluids at the top and bottom of the tower [462]. Another interesting interface measurement is that utilized to determine the brine/product interface in underground cavities used to store chemicals, such as ethylene, propylene, natural gas and nitrogen. These cavities are typically formed in underground salt layers, about 0.5 km deep, by brine extraction (solution mining). The position of the interface between the brine and the product changes as the product is introduced into or extracted from the cavity. Compton scattering was used to determine this interface by lowering a probe, consisting of a gamma-source, and a gamma detector, and measuring the backscattered photons [287]. An abrupt change in the amount of detected photons is indicative of the presence of an interface due to the change in density of the surrounding medium. Neutron backscattering for level measurement, see section 11.5.5.3, which mainly depends on the hydrogen content, can be used to detect the interface between two liquids with different hydrogen content. For example, the method has been used to monitor the interface between an aqueous solution and an organic liquid in an effluent holding tank and an oil-water separator in a plastic manufacturing operation [287].
11.5.7.
Leak Detection
Radiotracers are the obvious choice for leak detection of fluids, as they can follow the movement of the fluid and determine its flow rate, as explained in section 11.5.2. Under steady-state conditions, the flow rate remains the same at any location along the flow stream. Therefore, by measuring the flow rate at any two points along the flow one can detect any flow imbalance, which can be indicative of the presence of a leak. Also by injecting a radiotracer upstream of an isolation valve, or a relief valve, and determining the flow rate past the valve (which should be zero), any leakage through the valve can be detected and the rate of leakage can be determined. However, the most direct way for leakage detection by radiotracers is to detect the presence of the radiotracer outside the flow system. The radiotracer accompanying the leaked fluid will produce radioactivity outside the flow system. Such radioactivity will be concentrated in a location close to the point of leakage. Therefore,
504
Radiation Probing, Gauging, Imaging and Analysis
the presence of this radioactivity and its location enable the detection of a leak and the determination of its position. Reference [463] discussed a number of case histories in industrial installations in which radiotracers were utilized for lead detection. The (gas), (776.5 keV main gamma radiotracers used included and 35.3 h half-life) in the form of p-dibromobenzene or potassium bromide or ammonium bromide, as a sodium carbonate, and as a tritiated water. Note that is a beta-particle emitter, thus its radiation has limited penetrability, but is can be detected in a flow sample. Argon-41 was also used to find out whether heat exchangers in a nitric acid plant were leaking [464], by injecting a radiotracer at the inlet of the high pressure side of the exchangers and placing detectors at the outlet of the low pressure side (assuming that argon behaves the same way as the process medium). Reference [463] reported the use of radiotracers produced by neutron activation of In, V, Co, Mn and I, elements that were present in a water draining system; these radiotracers were also detected by sampling. Sealed components can be tested for leakage by exposing them externally to a radioactive gas, such as then removing the component away from the exposure and testing them for the presence of radioactivity, which would be then indicative of poor sealing. This concept was used for inspecting hermetically sealed components, such as valves, for gas-tightness [179]. Leak detection is also useful in studying ventilation systems, particularly those designed to carry hazardous gases. By monitoring the radioactivity emitted from the radiotracer, the flow passages of the ventilation system can be determined and any undesirable leakage can be found. Reported applications of radiotracers include studying the flow of gases in coal mines [179], and testing the ventilation system of a newly constructed unit producing a highly toxic chemical [277]. Moreover, in a closed system, the renewal time of ventilation gas can be measured by inserting a pulse of radioactivity and measuring the time it takes to return to the point of origin. The latter was used for determining the renewal time of air in laboratories and houses with the aid of krypton and xenon isotopes, and in metallurgical heat treatment furnaces [179]. 11.5.7.1
Buried Pipelines
Leaks in underground pipelines can be detected by injecting into them a radiotracer and measuring the presence of radioactivity in the adjacent soil medium. This can be done either by sampling of material from the soil and subsequent off-site counting, or by direct monitoring of radioactivity. Pulsed injection of the radiotracer is often used for leak detection. However, it is also possible to utilize continuous leak detection
Gauging
505
for continual monitoring of leakage. Continuous injection can also be useful for locating buried pipelines by monitoring the radioactivity on the surface of the ground. In addition, leak detection under no-flow (static) conditions is also possible, by filling under pressure the pipeline with a liquid or a gas containing the radiotracer then draining it after allowing some time for the radiotracer to seep through any holes or cracks to the adjacent soil medium. For a large leak due to a broken pipe, tracing the radiation emitted from a sealed source mounted on a sealed floating ‘pig’ can determine the location of the leak as the ‘pig’ will stop when there is no flow in the pipe after the break. For buried pipelines containing a radiotracer, the measured activity at the ground surface would be maximum at locations directly perpendicular to the pipeline and would drop rapidly, due to radiation attenuation and divergence, as the detector moves laterally away from the pipeline, unless their is a leak. In the presence of a leak, the level of radioactivity would become high at locations away from the direct location on the surface of the ground above the pipeline, because the radiotracer is no longer confined within the pipe walls but would disperse, along with leaked fluid, in the surrounding ground. In order for radiation to be able to penetrate soil and reach the ground surface, it must have a large penetration ability, while at the same time it should have a short half-life so that the leaked radiation decays quickly, leaving no adverse effect on the environment. is often used [463], as it emits high-energy Therefore, a source like (2.754 MeV) photons and has a half-life (15 h) that is long enough for practical use but is short enough to decay within a reasonable period of time. Another useful source is which emits, as indicated in Table 2.17, several high energy gamma-rays, but its half life of 2.58 h limits its usefulness to shorter pipelines. Also, (2.168 and 1.643 MeV gamma, 37.24 min half-life) is a useful radiotracer for tracking leakage in water mains [179]). For gas tracers, though mainly a beta-particle source, see Table 2.2, also emits gamma-rays in the keV range (mainly 151.2 and 304.9 keV, 4.480 h half-life). Other suitable gases are: (a beta emitter with 5.243 d half-life, useful for sample analysis), in the form of methyl bromide, radon 458, 571, 649 keV gamma, 2.4 h half-life) and (1.294 MeV gamma, 109.34 min half-life) [179]. Aside from the obvious advantage of being able to use krypton as a tracer with gas flows, it also enables the inspection of dry pipes. As a gas, argon can seep through the soil to the ground surface faster than a liquid, allowing a quicker inspection time [463]. For a
source, the total cross-section is about 4.15 × which results in a macroscopic cross-section of for a soil density of Assuming an exponential attenuation
Radiation Probing, Gauging, Imaging and Analysis
506
(that is ignoring the effect of buildup by scattering, see section 6.1), then a distance of 0.86 m will attenuate the radiation to Beyond this distance, for practical purposes, the intensity of the source can be considered to have been fully attenuated. Therefore, depending on soil conditions, the maximum depth of burial of pipelines beyond which the radiation emitted from a radiotracer can be detected is about one meter. At a deeper depth of burial, the radiation detector will need to be inserted in boreholes at some selected locations. An alternative approach is to monitor the radioactivity internally by installing a detector on a ‘pig’ carried by the flow, and sending the recorded measurement by telemetry. By introducing the ‘pig’ into the flow stream, some time after the injection of a radioactive solution [463], the detector would only register a high count rate if it encounters residual radioactivity deposited in the adjacent soil due to fluid leakage. The position of the ‘pig’ along the flow stream where the high count rate is registered defines the location of the leak, such position can be determined electronically (say using a global positioning signal), or mechanically, if the ‘pig’ is cable-driven into the pipe (say by a crane).
11.5.8.
Volume
In regularly shaped vessels, the volume of liquid in the vessel can be inferred from a level measurement, see section 11.5.5. However, when access to the container is not possible, or when the enclosure has a complex geometry (e.g. due to internal intrusions), or when it consists of many interconnected volumes, then the dilution of radiotracers is a powerful technique for volume measurement. The principle of volume determination is based on the conservation of mass, i.e. the mass of the radiotracer. If a radiotracer of measured total activity, is added of the same type of liquid contained in the to a known volume, vessel, it will result in a concentration of Now, if this injected radiotracer is allowed to mix well with a liquid of unknown volume, V, in the vessel, conservation of mass will dilute the concentration of the radiotracer to a value C such that: By taking a sample of volume, of the liquid from the vessel and measuring an activity, say one can determine the diluted concentration Then the unknown volume V can be calculated as For statistical validation, the measurements should be taken over more than one sample. Applications of this radiotracer-balance method for volume determination include: the measurement of inventory of mercury in chlorineisotope (279 keV gamma, 46.41 days); producing cells using an
Gauging
507
the quantity of sludge in crude oil stock tanks with (see Table 2.17) in the form of paradibromobenzene; the volume of a residual chemicalwaste deposits left on the side walls and bottom of a storage tank by indirectly measuring the vacant volume in the tank using a gas tracer (1.294 MeV gamma, 109.34 min half-life); and the volume of palladium catalyst deposits on the walls of a chemical reactor with a source (88 keV gamma, 13.7 h) [277]. The technique is also useful for the determination of the amount of molten metal in an ore-refining process [238]; a task difficult to perform in any other way.
11.5.9.
Gas Properties
Alpha and beta particles are more suited than other types of radiation for the inspection of gases, because of the low density of gases. As these charged-particles travel through a gas, they lose energy and intensity, and in the process can ionize the gas. All these features can be used to determine the density and pressure of a gas, as discussed in section 9.1. Note, however, that these parameters are related, e.g. for an ideal gas where refers to pressure, to density, M to the molecular weight (or mass number), T to temperature and to the universal gas The advantage of nuclear methods over constant; conventional methods is that they provide rapid response in the form of an electrical signal that can be monitored remotely. A charged-particle source, particularly, a beta emitter, can be seen as a replacement of the hot filament (cathode) used in conventional ionization gauge (also called ionization manometers) for vacuum pressure measurements. Such devices rely on the fact that any residual gas atoms left in a vacuum system are subject to ionization by electrons emitted from the filament as they collide with the gas atoms. However, the probability of ionization depends on the type of gas, since the stopping power of a material depends on the atomic-number, as discussed in section 9.1. The ionized atoms are collected with an applied voltage between the filament and an electrode. If the applied voltage, hence electron energy is sufficiently high, each electron is unlikely to collide more than once with the gas atoms at it travels towards the electrode. Then, the amount of ionization current will be directly proportional to the gas density, the more gas atoms the higher the chance that an emitted electron will collide with the gas atoms. Replacing the electron-emitting filament with a source of alpha or beta particles offers some advantages [238]: a stable rate of emission with a long half-life source; eliminating a heat source (hot filament) that stimulates chemical reactions between the gas and the filament and can lead to gas molecular decomposition; and long life-
508
Radiation Probing, Gauging, Imaging and Analysis
time, since there is no filament to burn out. The filament can also burn out if the voltage is increased to allow measurements at higher pressure. In addition, with an isotopic source, there is no need to apply high voltage to accelerate charged-particles, as they are already emitted with high energy. The higher energy also enables the measurement of gas pressure at elevated values. The short range of alpha-particles makes them the preferred source for such applications, as they produce the required ionization within a reasonable distance, allowing the placement of the source and the collecting electrodes close to each other, hence the construction of a compact device. At higher pressure, the effects of ion recombination, ion mobility, etc., play a more prominent role, as in the case of the gas-based detectors, discussed in section 4.2.2. These factors affect the linear relationship between the ionization current and gas pressure, making it more difficult to interpret the results, since these factors are difficult to predict. Nevertheless, the dependence of those factors, as well as the stopping power of the gas, on its composition and atomic-number makes it possible to use the ionization current as an indicator of the composition of a binary mixture of gases, at the same pressure. Reference [238] reported the use of this ionization method for measuring the relative content of an ammonia-argon mixture and a methane-air mixture (in coal-mine atmospheres). The method was used to measure the vapor pressure of fourteen different chemical compounds, enabling the determination of their latent heats of evaporation or sublimation alpha-source [465]. using a The energy lost by charged-particles, after traversing a gas, is also a function of the gas density and its nature. This energy loss can be determined by measuring the remaining energy of a beam after its transmission through gas. Measuring the particle energy requires the use of an energy-sensitive detector, such as surface-barrier semiconductor (see section 4.2.4), and recording and analysis of the measured particle spectrum. This method was used for measuring temperature changes at atmospheric pressure and the density of gaseous flames with alpha sources [238]. Reference [466] presented a method of gas composition indication by iteratively searching for the best fit between experimental and calculated alpha-particle spectra. The range of charged-particles is relatively easy to measure, as it is the distance at which all the particles are absorbed. Therefore, by placing a charged-particle source and a detector within a gas, at some distance from each other, and increasing that distance until the detector’s count rate practically drops to zero, the range of these charged-particles in the gas can be determined. Since the range is a function of the gas den-
Gauging
509
sity, as indicated by Eqs. (3.14), (3.21), the density of gas, or changes in density, can be determined. Changing the distance between the source and the detector can be a tedious task. Therefore, an alternative arrangement is preferred. With beta-radiation, use can be made of the exponential nature of its attention, Eq. (3.23), to measure the intensity of the transmitted radiation and relate it to density. The exponential nature of beta-particle attenuation is due to the wide and continuous distribution of its emission energy, as discussed in section 3.3.2. However, due to the relatively long range of beta-particles in gases, sources of alpha-particles are preferred as they allow the placement of the source and detector within a reasonable distance from each other, for device compactness. Although alpha-sources are monoenergetic (see Table 2.1), their emission can be given, like beta-particles, a wide and continuous energy distribution by using a thick source, where self-absorption within the source material results in the emission of alpha-particles over a wide range; nearly full energy from the surface of the source, minimum energy from the center, and intermediate energies from in between. With a thick alpha-source, the intensity of transmitted radiation can be used to measure gas density (or pressure). At a constant pressure, the intensity of the transmitted radiation can be utilized to determine the relative content of a binary gas mixture, taking advantage of the dependence of the particle range on the atomic-number of the gas, see Eq. (3.14). The attenuation of a thick alpha-particle source was used for measuring the atmospheric air pressure at different altitude and for determining the relative content of a helium-oxygen gas mixture [238]. In spite of their long range, the forward scattering of beta-particles was also used for measuring the density of air at high altitudes, taking advantage of the dependence of the scattering probability of beta-particles on density, as discussed in section 11.1.3. At constant pressure, the density of the gas becomes indicative of its temperature (or more accurately its inverse temperature since for an ideal gas). Then, the gas temperature can monitored by radiation transmission. Using this principle, the transmission of beta-particles was used for measuring the flame temperature in an oxygen steel furnace [179]. The longer range of a beta-particles allows positioning the source and detector away from each other and from the flame, a desirable situation under these high temperature condition. This is a unique way for performing nonintrusive measurements under such harsh conditions. Air humidity can be measured with an ionization chamber that uses atmospheric air as its ionizing gas. To induce ionization, an alphaparticle source is located within the chamber; alpha-particles are used as a source to provide a high ionization current. Humidity introduces
510
Radiation Probing, Gauging, Imaging and Analysis
liquid (water) particles into the air passing through the chamber, which act as recombination centers that decrease the ionization current. Reference [467] reported the use of a double ionization arrangement to enhance the sensitivity of the ionization current to changes in humidity. Each chamber had its ionization source but both shared the same ion collecting electrodes. While one chamber had many small holes to allow atmospheric air through, the other chamber was sealed at atmospheric pressure and kept dry by means of calcium chloride particles. The effect of changes in atmospheric pressure and temperature were minimized by applying a reverse potential voltage in one channel, relative to the other, with the magnitude of voltage bias adjusted so that when the atmospheric air was dry, the cumulative current of the two chambers was zero. Therefore, increased humidity of the air entering the unsealed chamber leads to an imbalance in the voltage of the double chamber, which produces a current, the magnitude of which increases with humidity. Humidity was measured to an accuracy of ±5% with this method [467]. The dew-point can also be obtained from humidity measurements, since the-dew point is normally reached at a relative humidity of atmospheric air of 100 % (i.e. at saturation). The temperature corresponding to this saturation level is the dew-point, i.e. the temperature at which water vapor condenses from air into liquid or solid, forming dew, frost rain or snow. Note that when the dew-point is below the freezing temperature, it is called the frost-point.
11.5.10.
Flow Distribution
Radiotracers provide a direct method for examining the distribution of flow across a plant or open channels. By monitoring the intensity and time of arrival of a tracer at designated points, the flow pattern can be determined. Indications of flow distribution can be obtained by studying the travel time (also called the residence time) of a radiotracer pulse. Early applications of flow-pattern investigations included the study of sewage discharge into the ocean, using and as radiotracers. The method was also used to study the distribution of potential leakage of petroleum products or toxic chemicals into a river, and the subsequent arrival at a water treatment plant [277]. The deep ocean sewage outfalls off Sydney Australia were also evaluated using and or [447]. The spread of subterranean termite colonies either in both forested and urban areas was traced with or in an inert form, by inserting them in a feeding location of a wooden dowel [468]. The retention and migration in a wastewater treatment plant of fiber components containing polyacrylate polymer (used in a number of absorbent consumer products) was studied by tagging of the polymer
Gauging
511
of fiber introduced into the treatment unit [469]. The flow pattern in the leaching tank of a nitrate production process was studied by injecting a pulse of at the inlet of the tank and measuring the activity of samples extracted at the outlet of the tank [470]. The existences of a dead-volume (where solution may be retained) in the corner of the and radiotracer tank was also studied with the aid of simultaneously injected into two corners of the tank [470]. When separate flow passages are present, direct flow-rate measurements, using the methods discussed in section 11.5.2, can be used to determine the flow distribution. Such measurements were used to determine the water flow distribution among the branches of a waste-heat tracer; for studying the flow dispersion of sulfuric acid boiler using a as a tracer; in the reticulation system of an alkylation plant with and for studying the flow distribution in gas distribution networks [445]. Radiotracers have also been used to measure the diffusion coefficient of one substance within another [471]. The diffusion of a radiotracer introduced into a medium will increase the count rate of the radiation emitted from the radiotracer with time as follows:
where N is the count rate at time is that recorded at count zero is the saturation concentration, is a constant related to the and diffusion coefficient where D is the diffusion coefficient in a diffusion cell of length L [471]. The sliding cell method described in reference [471] allows smooth introduction of the tracer material from one cell to another to establish the diffusion process. The same reference described the measurement of self-diffusion in an tracer, by diffusing a radioactive solution into a system, using a non-radioactive one.
11.5.11.
Void Fraction
The gas phase in a multiphase flow is generally viewed as representing a ‘void’ due to its low density. This makes the volume fraction of the gas phase, called the void fraction, particularly amenable to measurement by penetrating radiation, due the negligible effect the gas phase has on radiation, in comparison to liquid or solid. Beta-particle transmission was used for void-fraction measurement, see for example reference [472]. However, this method is limited to high void content, e.g. dispersed water in steam, and the low penetrability of beta-particles necessitates a special thin-window arrangement, restricting its use to low-pressure systems. Gamma transmission is the most common method used for
512
Radiation Probing, Gauging, Imaging and Analysis
void-fraction measurement, in a process known as “densitomtery”, as it in effect measures the density of the non-void phase in the flow. The density-dependence stems from the use of radiation sources with photon energies where Compton scattering dominates, such as see Table 2.10 for energies and half-lives. At lower photon and Tm, energy, and in the presence of metal, the photoelectric effect can slightly alter the dependence of the device on density. Using the transmission model of Eq. (6.2), assuming linear density-dependence of the total crossaccording to section and expressing it in terms of the void-fraction, Eq. (E.16), the void fraction in a pipe can be estimated as:
where I refers to the intensity of the transmitted radiation and the and designate the intensity measured when the pipe is subscripts and are determined full of liquid or gas, respectively. The values of in-situ, to directly account for the attenuation of pipe walls and changes in the source intensity by radioactive decay. This gamma-transmission method is widely applied for void-fraction measurement of gas-liquid two-phase flow in tubes, annuli, rod bundles and nozzles [473]. The measurement model of Eq. (11.13) is based on the transmission model of Eq. (6.2), which requires a narrow-beam so that the buildup of radiation by scattering is negligible. A narrow-beam passing through one chord provides an estimate of the void condition only in that chord. If the flow is not homogeneous, then the estimated void-fraction will not be representative of the entire flow condition within the monitored channel. A wide-beam can be used for this purpose, with provisions made to account for the uneven distribution of the beam profile. This broad-beam approach is, however, limited to small pipes (about 13 mm in diameter), since for larger pipes the transmission response from one end of the pipe can considerably differ from that at its center, thus complicating the interpretation of results [238], which may also be further affected by the contribution of multiple scattering. To overcome this problem, a multi-beam densitometer is employed [473]. This is typically done using one source housed in a shielding container equipped with beam ports (long holes acting as collimators), directed towards the flow channel, typically three [474]. These ports provide in essence multiple beams emanating from the same point (source location), but traverses the flow channels at three different locations along the same section of the channel. Transmission along each beam is recorded, and Eq. (11.13) is applied to each measurement to estimate the void fraction along each beam. The average of the obtained values provides an estimate of the
Gauging
513
overall (global) void fraction within the flow channel, while the variability of the measurements provides an indication of the distribution of the void, or the so-called flow regime. X-ray multi-beam systems were also devised [473]. An interesting x-ray transmission method was reported in reference [475], where the metal walls of the pipe were used to generate x-rays, by bombarding it with beta-particles emitted from a pure betaThe transmission of the generated bremsstrahlung source x-rays was then measured and used to determine the void fraction in a vapor-water mixture. The generated x-rays have an energy that depends on the thickness of the target, but with an effective energy of less that 20 keV. This limits the technique to small tubes, to a maximum of about 8 mm in diameter. The method is also limited to metal walls thickness of about 0.65 mm of steel (or the equivalent), since beyond that thickness the generated x-rays are self-absorbed within the wall. However, such a technique can be useful for studying the flow in small tubes, where conventional sources of x-rays and gamma-rays generate too high a photon energy. Another way to overcome the limitations of single-beam transmission is to employ a scattering technique. Photons are Compton-scattered mainly by the liquid phase, consequently the number of scattered photons is proportional to the liquid content. With high-energy photons, the number of scatters can be limited to one per source particle, making it relatively easy to interpret the results. Reference [212] reported the use of a collimated beam of 9 MeV photons produced by neutron bombardment inside a reactor with a 3 kg nickel target (via the thermal neutron capture with The photons were made incident on a 25 mm plastic tube, and the scattered photons were measured with a NaI(Tl) detector at angle of 20° with the beam. The scattering intensity, at a void-fraction, was modeled (see section 7.5), assuming single scattering, by the relationship:
where is the scattering cross-section for the liquid phase, Reference [476] showed also that information on the spatial distribution of the two phases can be obtained from scattering measurements. A very intense beam, as that extracted from a reactor using a large target, is required to compensate for the fact that most liquids are low in density and as such are not very effective Compton scattering targets. This lowprobability of scattering is also further suppressed if the pipe walls are made of a metal, since metals are more effective Compton-scattering material; as Eq. (3.40) indicates. Photon scattering from the surrounding
514
Radiation Probing, Gauging, Imaging and Analysis
shielding and collimator material further increases the competing background signal. Therefore, the signal (from the liquid) to background ratio tends to be small, necessitating very long counting periods, even with a considerably large source. The backscattering of x-rays from 40 mm diameter steel tube (2.5 mm thick) was used for measuring the void-fraction in air-water flow [477], using four detectors and a wide fan-beam, with the stream line of the flow parallel to the plane of the fan-beam. Reference [478] presented a system that employs an source and cadmium zinc telluride (CdZnTe) detectors to measure radiation at 17 different positions around an aluminum pipe (80 mm inner diameter and 5 mm thick). With energy discrimination, the photon scattering component, with energy less than the source’s 60 keV, can be separated from the uncollided (transmission) radiation. The scattering, along with the transmission detector responses, were used to determine the void fraction and identify the flow regime in oil-gas mixtures. Activation techniques can also be used to produce secondary radiation emitted from the liquid in all directions. Nuclear activation can be useful for this purpose, but the generally low activation cross-section of neutrons in most flow materials results in a low count rate, or demands the use of an intense source. However, photon-activation was employed with heavy-water flows, taking advantage of the photoneutron reaction, see section 12.1.1.2. A photon source of energy above 1.67 MeV can be used to trigger neutron emission from the deuterons of the heavy water. The the amount of emitted neutrons would then be proportional to the density of the boiling heavywater flow, hence to the void fraction [479]. In high-pressure systems, where thick-metallic walls are used, the contribution of the metal to the detector response can far exceed that of the fluid, due to the higher electron density, hence high macroscopic cross-section, of metal. Neutrons, on the other hand, are generally less affected by metals than photons. Therefore, thermal-neutrons extracted from a reactor were initially used for void-fraction measurement, in a beam-transmission arrangement [480, 481, 482, 483]. Thermal-neutron beams obtained from the slowing-down of neutrons emitted from isotopic neutron-sources were also used [484]. Since the efficiency of the neutron slowing-down process is not every high, due to the loss of neutrons in the moderation process, some workers took advantage of the slowing-down ability of the hydrogenous liquids to provide such moderation. The first attempt in this regard measured the transmission of fast-neutrons emitted from an Sb/Be neutron source (see Table 2.17 for properties) with a thermal-neutron detector, and dissolved boron in the fluid to increase its absorption cross-section [485]. The detected thermal-neutron count
Gauging
515
becomes then dependent on the amount of boron in the pipe, hence the liquid, and in turn the void fraction. This technique requires sufficient amount of hydrogenous liquid for the incident fast-neutrons to be slowed-down by liquid, then absorbed by the boron. Therefore, this slowing-down/absorption, technique was applied to water pipes of diameters ranging from 76 to 200 mm in diameter. However, by proper pre-moderation of the incident source neutrons, the need to use boron can be eliminated, and direct scattering of neutrons can be used for void fraction measurement, see reference [213]. This technique, called neutron scatterometry, has been applied for measuring the void fraction of boiling-water in high pressure metallic pipes as small as 22 mm in internal diameter, I.D., (3 mm thick) [486] to as a large as 100 mm I.D. (10 mm thick) [487] and 113 mm in I.D. (7.1 mm thick) [488], and in a rod bundle channel (44.8 mm internal diameter, 4 mm wall thickness, with seven solid metallic rods, each 13.1 mm in diameter) [489, 490]. Phase-distribution information was also deduced from the pattern of the scattering measurements change with time [491]. Fast-neutron scattering was also used for measuring the gas content in a degassing unit used to entrain an inflammable hydrocarbon gas in a plastics intermediates plant [289]. Measuring the interfacial area between the phases of a multiphase flow is a challenging task. One approach to applying radiation to this measurement problem is to place a beta-source in one phase and a scintillating material in the other phase. The number of beta-particles crossing the interface, and causing scintillation in the other phase, will be proportional to the interfacial area, if the beta-particles are absorbed within a short range within the scintillating phase. The intensity of the emitted light becomes, therefore, a measure of the overall interfacial area between the phases. This concept was experimentally verified using an aqueous being the beta-source), interfacing with solid tritium solution (with and liquid scintillators [492]. This concept proved, however, not to be practical, due to the difficulty of limiting the presence or solubility of the materials of the beta-source and/or the scintillator within a single phase.
11.5.12.
Multiphase Flow
Although gamma-ray transmission can be used to measure the overall density of a multiphase flow, as the applications in section 11.1.4 showed, it cannot distinguish between the phases. However, the dualenergy gamma-ray transmission method, discussed in section 6.5.3, can be used to provide such information. It was, therefore, used to measure oil, water and gas volume fractions [493, 494, 495, 496, 497]. While a
516
Radiation Probing, Gauging, Imaging and Analysis
high-energy source, such as (662 keV) or (356 keV), can be used to measure the density of the fluid, a low-energy source, such as provides effective atomic-number (composition) information. The three-phase oil relative permeability can also be deduced from such measurements [498]. Using this technique, it becomes possible to determine the fluid saturation distribution as a function of the volume of gas injected; with the aid of three-phase oil relative permeability curves deduced from oil saturation profiles using analytical calculations. The saturation of nonaqueous-phase liquid in water within sandy porous media and soil was measured with dual-energy gamma-radiation systems [499, 500, 501, 502]. Measurement of the cross-correlation between gamma-transmission measurements of the two gauges, one downstream of the other, can be used to determine the flow velocity [494, 495]. A multi-energy photon-transmission system was also used to account for the change in water salinity in such three-phase flow systems [503]. The diffraction pattern, discussed in section 7.7.4, was also used to measure the oil-to-water ratio, taking advantage of the difference of the diffraction pattern of oil and water. With a 70 kV tungsten x-ray, the diffraction profile for oil (kerosene), when normalized to water, peaks between 15 to 25 keV and is minimum between 32 to 45 keV [504]. The ratio of the diffraction intensity at these energies provides, therefore, an index indicative of the oil-to-water content. In the presence of void that may be present in a multiphase (oil-water-vapor) flow, the scatter-ratio is corrected by the ratio of the logarithm of the transmission measurements obtained at these energy windows, since each transmission measurement is mainly affected by the presence of void and becomes a function of the liquid fraction. The ratio between the two transmission measurements eliminates the effect of void, as one can deduce form the measurement model of Eq. (6.1). It should be kept in mind, however, that a small container of non-metallic material should be used to allow for photon penetration; reference [504] utilized a polypropylene vessel, 60 mm in diameter and 1 mm thick. Talking advantage of the salinity of underground water, and the subsequent increase in its neutron absorption cross-section of thermalneutrons (due to the presence of chlorine), reference [505] reported the use of the transmission and scattering of fast-neutrons from an Am/Be source. The gas-fraction is determined from the transmission measurement, since it is mainly a fast-neutron measurement that is affected most by the absence of material (void). The relative oil-to-water measurement is then determined from the normalization of a slow-neutron scattering measurement, corrected for void fraction, since the scattering from water
Gauging
517
of slow-neutrons is reduced by the absorption in chorine. The method requires, however, a priori knowledge of the level of salinity in water.
11.5.13.
Isotope Hydrology
Isotope hydrology is the term that describes the use of environmental isotopes (see section 8.8.2) to study the hydrological cycle of the waters of the Earth and its interaction with the environment. A good number of studies have been conducted using radioisotopes, a few of which are mentioned here. References [506] and [507] describes how environmental isotopes are used to study ground-water pollution problems, while reference [508] is a good source for information on the use of environmental isotopes (and related tracers) in a variety of applications in hydrology, geology, and biology. A few representative applications are given here. Some isotopes can be used as tracers of water, nutrient, or solute sources. The concentration of tritium can reveal the occurrence of recent ground-water recharge (over the past few decades, due to its limited half-life of 12.43 years), which is indicative of the increased potential of contamination as the ground-water would not have sufficient residence time for the water to become absorbed in the aquifer matrix. The concentration of uranium and thorium (and the activity emitted by their daughters), is useful for studying the movement (pathways) of underground water. The natural fractionization of the even uranium isotopes and by the alpha-decay of the latter, is useful for studying dynamic processes in the hydrosphere. The spatial and temporal variation of the ratio of the concentration in underground water (or disequilibrium) is used for studying ground-water formation and circulation, and for modeling the hydrogeological conditions in mountains areas during floods [509]. Naturally occurring isotopes in the environment are also used to estimate the age of very old ground-water [510], using Reference [511] covers many of the applications of environmental isotopes in hydrology. Radiotracers (such as were also used for measuring the flow rate of ground water [512]. Beryllium-10 (a beta-only emitter with half-life ) is one of the comsogenic nuclides produced by cosmic-rays (spallation of O and N). It exists as a solution in the slightly acidic rain-water, and upon precipitates out of solution as the reaching the ground surface, can be used water becomes more alkaline. The accumulation of to study soil erosion and formation. The shorter-lived cosmogenic (53.28 day, half-life) can be measured in the ground as evidence of recent rainfall, as well as in stream-water to determine the direct contribution of rainfall. References [513] and [514] provide more details on the applications of cosmogenic nuclides in hydrology and related fields.
Radiation Probing, Gauging, Imaging and Analysis
518
11.6.
Dating
Dating is the process of finding the age of an object. Long-lived radioisotopes are particularly suited for this process, since their concentration varies with time. It is, however, necessary to know the initial concentration of the radioisotope, in Eq. (3.156), to relate it to the current concentration, N, hence determine the lifetime, using Eq. (3.156), knowing the decay constant (or half-life) of the radioisotope. A number of radioisotopes are suitable for use in dating studies as discussed below. Atmospheric cosmic-rays produce via the reaction: The generated is rapidly oxidized to form which enters plant life (via photosynthesis) and animal and humane life (via the food chain). An equilibrium between the concentration of and non-radioactive carbon exists in living biological cells. There is one atoms of in living material. As soon as atom for every terra a living-organism dies, the metabolic function of carbon uptake ceases, and no fresh supply of carbon is provided. The concentration of then begins to decline by radioactive decay, with a half-life of 5715 y. The concentration of relative to the equilibrium concentration is, therefore, indicative of the time passed since the death of the livingbecomes organism. After about 10 half-lives, the concentration of very small, practically undetectable. Therefore, carbon-dating is limited to a maximum of 50 to 60 thousand years. The decay of results in the release of beta-particles with a maximum energy of 157 keV (with is, therefore, measured no gamma emission). The concentration of by beta-particle counting. Since the presence of carbon is usually associated with biological processes, any material that contains carbon may be dated. Reference [515] lists some of the types of carbonaceous samples that have been commonly dated using These are: charcoal, wood, twigs and seeds; bone; marine, estuarine and riverine shell; leather; peat; coprolites; lake muds (gyttja) and sediments; soil; ice cores; pollen; hair; pottery; metal casting ores; wall paintings and rock art works; iron and meteorites; avian eggshell; corals and foraminifera; speleothems; tufa; blood residues; textiles and fabrics; paper and parchment; fish remains; insect remains; resins and glues; antler and horn; and water. The same reference [515] presents also an impressive list of the fields in which carbon-dating has been applied. Theses include: archaeology (Dead Sea Scrolls), oceanography (ocean sediments), palaeoenvironmental studies (palaeovegetational reconstruction of the North and South American continents), dendrochronology (ancient bristlecone pine), palaeoclimaCarbon-14.
Gauging
519
tology (palaeoclimates and solar variation) and meteorology (examination of Martian Meteorites); Tritium. Cosmic radiation produces tritium in the upper atmosphere, supplying a constant, though low, quantity of tritium to all precipitation (rain and snow). Therefore, tritium is used to date water that seeps underground, where it becomes protected from exposure to cosmic rays. Tritium dating is achieved by measuring the concentration of tritium in water [179] and comparing it to the equilibrium concentration. However, because of the relatively short half-life of (12.32 y), the method is limited to a maximum age of about 50 years. Thus tritium dating is used to determine the age of “young” ground-water. It should be kept in mind that some excess tritium may be present in water due to the thermonuclear weapon explosions that were performed during and following World War II. Cosmogenic Nuclides. In addition to other cosmogenic nuclides (see section 2.4) can be used for dating. Such include (a pure and (a positron and a gamma beta emitter, half-life These nuclides are produced in quartz crystals of emitter, rock and sand, and found in lakes and rivers due to rock erosion. The longer the rocks are exposed to cosmic rays, the higher the concentration of these radionuclides in the rock, and consequently in river and lake sediments. These isotopes can, therefore, be used for dating river terrace sediments [516]. Other isotopes that can be employed in radioactive dating include, half-life) and (22.6 y, half-life). The long halflife of makes it useful for measuring the age of water for up to 2 million years, since chorine is usually present in water. While is used to date layers of sand and soil up to 80 years [349]. Thermoluminescence. Natural activity, from naturally radioactive materials as well as from cosmic-rays, excites buried crystalline materials. Most of the excited electrons return quickly to their stable state, but a few become trapped for a long time within the crystal and stay at the excited state. These trapped electrons retain a “memory” of the history of their radiation exposure, which can be tapped into by heating the crystal to a temperature high enough to release the excitation energy stored in the crystal with a subsequence emission of luminescence light. If the crystal is cooled and then re-heated, this excess energy will be liberated, and no subsequent light emission can be released. This effect is known as thermoluminescence (TL); it is the same process utilized in
520
Radiation Probing, Gauging, Imaging and Analysis
badges used to monitor personnel exposure to radiation. The intensity of emitted light peaks at temperatures that produce thermal energies sufficient to release the excited electrons from their various traps. The intensity of these TL peaks increases as radiation exposure increases, and thus can be used to determine the age of the crystal, in a process known as TL dating [517]. The age of material is determined from the radiation dose corresponding to the intensity of the recorded light and the average annual radiation dose. Materials which may be dated with this methods are flint (or stone), stalagmitic calcite, sediments and ceramics [518]. Thus the method is used in archeological studies [519] as in the dating of Egyptian pottery [520], volcanic materials [521], sediments [522], bricks structure [523], and even space planets [524], and for investigating the irradiation history of dates and nuts [525]. Various ceramic materials (pottery, bricks, cooked clays, bronze clay-cores) have been also dated by thermoluminescence using the emitted natural radiation [526]. The technique is also used in forensic dosimetry after a radiation accident. For example, this method was used to measure the external exposure dose in the contaminated area near the Chernobyl Nuclear Power Station by measuring the thermoluminescence of quartz in bricks [527].
Chapter 12 ELEMENTAL AND CONTENT ANALYSIS
Elemental analysis is the ability to identify all elements, or some of the elements, present in a material. Content analysis, on the other hand, refers to determining the relative content of known materials in a mixture. For example, determining the elemental composition of soil means identifying the elements in the soil (oxygen, silicon, etc.) and their weight fractions. Also determining how much hydrogen in the soil (say due to water moisture) can be considered as elemental analysis concerned with the detection of one-element (hydrogen). On the other hand, determining the amount of water and soil in mud is considered to be content analysis, since it is known in advance that the mixture contains water and soil, but their relative content is not known. Note that radiation methods in general do not provide explicitly the chemical composition (formulae) of a material, since radiation interacts with either individual electrons or nuclei or their fields, as discussed in chapter 3. Therefore, the effect of chemical bonds on radiation interactions is not very prominent. Molecular information can, however, be extracted when radiation is sensitive to the thermal motion of individual molecules, or possess wave properties that are influenced by the molecular structure of a material, or when the radiation energy is quite low to be affected by electronic (chemical) bonding. Therefore, when the term “composition” is used in this chapter, it refers in general to the overall elemental or material composition of matter, rather than its explicit chemical form. An element can be identified as a nuclide (i.e. by its nuclear properties) or as or as an atom (i.e. by its atomic electrons). While nuclear methods are more specific and can distinguish between two different isotopes of the same elements, atomic methods are also useful in some applications, particularly when the primary interest is in the overall chemical nature of 521
522
Radiation Probing, Gauging, Imaging and Analysis
material. Nuclear methods require radiation that can reach or is affected by the nucleus, thus they utilize the techniques discussed in sections 12.1 and 12.2. Since the number of elements to examine is too enormous to consider one element at a time, this chapter classifies the applications in terms of the technique used. However, the measurement of hydrogen, being one of the most common elements in nature, is discussed in a separate section (12.3). The process of content analysis is discussed in section 12.4.
12.1. Nucleus-Based Analysis 12.1.1. Activation Analysis Activation analysis is perhaps the most definite method for multielemental analysis, since each element provides its own characteristic nuclear emission, regardless of its chemical composition. Though activation analysis is often performed in nuclear reactors or with the aid of large accelerator facilities, it can also be done in situ, using isotopic sources or portable generators. While delayed emissions are often monitored in reactors, prompt emissions are used in applications requiring on-line analysis. The high accuracy of activation analysis and its ability to detect trace amounts of elements adds to the viability of the technique. However, activation by certain types of radiation are more suitable than others. Some methods offer low activation cross-sections, while in others interference between various elements present in an object can obscure a desired indication. This section presents some of the applications in which various techniques have proved to be useful. The techniques are classified primarily in terms of their radiation sources; unlike in chapter 8 where the methods were categorized first by the nature of emitted radiation.
12.1.1.1
Neutron Activation
The ability of neutrons to easily penetrate the nucleus makes them very useful in many elemental-analysis applications by neutron activation, as discussed in this section.
Thermal-Neutron In – Prompt-Gamma Out . Prompt-gamma neutron-activation analysis requires immediate counting of emitted radiation. This necessitates a system arrangement in which the interrogated object and a gamma detector are present at the same time and place, thus prompt-gamma neutron activation cannot be performed within a reactor core or inside a neutron-thermalization assembly. Since there are no direct sources of thermal-neutrons, these neutrons have to be ex-
Elemental and Content Analysis
523
tracted from a reactor, a neutron moderation-assembly that includes an isotopic neutron source, or a neutron generator. A collimator is then used to extract a neutron beam of thermal-neutrons that is directed to the investigated object. The design aspects of these collimators and moderation assemblies are discussed in sections 15.1 and 15.3, respectively. References [528] and [529] describes some of the reactor-based facilities available around the world for performing prompt-gamma activation analysis. Sub-thermal (cold) neutrons can also be used for promptgamma activation. Reference [530] presents a data-set that provides the energy of prompt gamma-rays induced in 79 elements resulting from the activation by sub-thermal (cold) neutrons. A variety of photon detectors can be used for detecting the emitted radiation. Obviously the detector has to be able to measure the energy of the emitted photons, to uniquely identify the originating element. The detector used has also to be resistant to neutron damage and insensitive to neutrons, since even if the detector is well-shielded from the source neutrons, some neutrons may scatter off the object and reach the detector. In this regard, and in NaI(Tl) detectors become activated to and respectively. While the decay of results in two emits many prominent gamma-ray energies at 1.369 and 2.754 MeV, weak gamma-rays ranging in energy from 3.770 keV to 1.434 MeV. These internally emitted photons further scatter within the detector, creating a background component that can interfere with the measured spectrum of photons incident on the detector. While a BGO detector is not as susceptible to neutron internal activation, its casing can be activated, causing interference with the detector response. Such interference can be quite severe at high neutron flux. Semiconductor detectors, such as Ge(Li) and HPGe detectors, are also subject to crystal damage at high neutron flux. Prompt thermal-neutron activation (TNA) can been used for the detection and measurement of the concentration of many elements, see section Table 8.3. A unique feature of this activation method is its ability to detect cadmium and mercury, two of the toxic elements that evade delayedneutron activation analysis [247]. Although (12.22% abundance) is the cadmium isotope with the highest thermal-neutron capture crosssection (20.6 kb), it produces upon neutron absorption a stable isotope, However, the reaction produces 0.559 MeV photons, see Table 8.3. Similarly, although is the isotope of mercury that has the highest capture cross-section (2.2 kb), it produces a stable isotope, while emitting a prompt gamma energy of 0.3681 keV. Therefore, the technique is useful for the measurement of cadmium and mercury in environmental samples. Other example industrial ap-
524
Radiation Probing, Gauging, Imaging and Analysis
plications include the detection of boron in semiconductors and glass, analysis of archeological samples, and on-line analysis of coal and minerals. The technique was also used in mineral exploration and welllogging [247, 256]. The thermal-neutron prompt-gamma technique has been used to determine the concentration of major elements in coal (H, C, N, S), ash (Al, Si, Ca, Fe) [531, 532, 533], limestone (used in manufacturing cement (H, C, Ca, Fe) [532] and a raw glass mixture (for Na, Si and Ca) [533]. The viability of using the same technique was also investigated for offbelt bulk analysis of coal to optimize production, processing and quality operations in coal mines [534]. The technique was also used for the determination of ash, Fe, Si, and Al of coal seams in water-filled boreholes [535]. The percentage of Al, Si and Fe in core were correlated to the deformation temperature and the slagging index of coal1 [535]. In well-logging thermal-neutron activation is utilized for the detection of chlorine, which is usually present in the saline underground water, for localizing oil-water contacts, with the water and oil supplying the thermal-neutrons by slowing-down fast-neutrons emitted from a fastneutron source, such as Am/Be, Pu/Be [40], or a 14 MeV neutron generator. Natural chlorine produces high-energy activation-gamma peaks in the range from 6.6 to 8.6 MeV [246], which are easily detectable. The hydrogen content can also be detected by its 2.223 MeV gammarays, to provide an indication of the shale content and porosity (see section 12.3.1) that can be used to correct for the dependence of salinity on these two factors. The activation peaks from silicon (3.54, 6.38 MeV) and calcium (4.42 and 6.42 MeV) are also useful indications in formation lithology2; though silicon is also detectable by fast-neutron elastic scattering, see Tables 8.5 and 8.6. The salt and sulfur content, relative to that of hydrogen, in a flow stream of crude oil, was determined using an Am/Be source and monitoring the activation gamma-rays of Cl and sulfur, using two characteristics gamma-energies, and hydrogen at 2.223 MeV [536]. The overlapping of the activation gamma-rays from Cl and S, as well as from other elements, were accounted for via a calibration process. The prompt-gamma emitted from the thermal-neutron capture reactions (7.64 MeV gamma) and (1.78 MeV 1
The slagging and fouling of coals during combustion can be predicted by heating a laboratory prepared coal ash in a controlled atmosphere. Initial, deformation softening, hemisphere and f luid (flow) temperatures are recorded. The slagging index is defined in reference [535] as 2 Lithology is the study of stones, rocks or rock formation, in terms of composition, color, texture and structure.
Elemental and Content Analysis
525
gamma) was used for continuous determination of, respectively, iron and alumina in iron ores, using a moderated source [384]. Since does not decay promptly, it has a half-life of 2.3 minutes, a detector down-stream of that used for detecting the prompt-gammas of was employed. The iron ore was placed on an auxiliary conveyor belt moving at speed of less than 3 m/minute to allow the detection of the gammas before they significantly decay. The reaction was also used for determining the aluminum content in bauxite and coal samples with a well-thermalized source [384] A similar application is reported for manganese-grade well-logging [537], and for the elemental analysis of diabase rock (a rock similar to that found under the ocean) [538]. Reference [539] reported the use of this technique to investigate the elemental composition of a phosphate ore. Thermal-neutron activation was used for in situ survey of water pollution by elements such as Hg, Ni, Cl, Fe, Cu, Mn, Cr, Ag, Pb and Zn [540, 541, 542] and for mineral exploration in sea bed [543]. Thermal-neutron activation was also proposed for detecting explosives in airline passenger luggage [544, 545]. Nitro explosives are rich in nitrogen, which is indicated by the emission of a 10.829 MeV gammarays [246]. A similar approach with a source, was used for confirming the presence of a landmine detected by another conventional method (metal detector, ground probing radar and infrared imaging) [546]. Reference [547] assessed the suitability of various neutron sources for use in reaction, showing that a neulandmine detection via the tron generator based on the He reaction and a source are most suited for this purpose. Narcotics, on the other hand, are rich in chlorine, which can be detected by the many gamma-ray peaks it produces [246]. Therefore, thermal-neutron activation was also considered for detecting drugs concealed in cars, trucks and large cargo containers [548]. Such a system can be used for “inspection before an unloaded cargo container from a ship is moved to temporary storage, inspection of trucks unloaded from a ferry, or inspection of vehicles parked close to Federal building or military bases”. The thermal neutrons used in theses techniques are produced by slowing-down neutrons emitted from an isotopic source, namely, or neutron generators [549]. Thermal-Neutron In – Delayed-Gamma Out. This is perhaps the most widely used activation-analysis technique. It can be applied to almost 50 elements. Since the irradiation and counting processes are performed separately, the precautions required to protect a detector against neutron exposure in prompt-gamma activation are not needed in delayed activation. The separation of irradiation and detection allows the per-
526
Radiation Probing, Gauging, Imaging and Analysis
formance of the latter under a low background field, thus improving the statistical confidences in the measurements, see appendix G. Statistical uncertainty can also be further enhanced by increasing the irradiation time and/or the counting time. It also becomes possible to position an object within the neutron field, i.e. within a reactor or a moderation assembly; an efficient way of using the neutron source, by eliminating the need for neutron extraction and collimation. However, this “in-core” irradiation makes it difficult to use the method in on-line or in situ analysis. On the other hand, in-core analysis is limited to small sample sizes and is not suited for heat-sensitive, volatile and unstable materials. Nevertheless, the ability of the technique to provide accurate determination of the elemental concentration of even trace amounts, makes it a very attractive technique for non-destructive analysis of small samples, that may be extracted from a larger object without affecting its usefulness. The detectors used in this method are similar to those employed in prompt thermal-neuron activation, i.e. detectors that are capable of measuring the photon-energy spectrum. The applications of delayed neutron-activation are too many to detail here, but a few representative examples are presented. An on-line system was developed for detecting the presence of vanadium (a highly corroding element) in crude oil and in heavy distillate fuel: via the reaction The latter element decays with a 3.76 minute half-life, emitting 1.434 MeV photons [550]. The thermal neutrons required for this reaction were produced using a moderated source, and the irradiated liquid was transferred to a detection unit with the aid of rubber tubing and a pump. Delayed neutron-activation analysis, with a high resolution gamma (germanium) detector was also applied in well-logging to provide elemental analysis for Na, Mg, Mn and V [551]. In-core (reactor) thermal-neutron activation analysis is used for measuring the concentration of a wide variety of elements in samples, see Table 8.2. Metal alloys, semiconductors, concrete, pottery, glass, bones, plants, forensic samples (e.g. gunshot residues and hair), greases, wood, soils, drugs, plastics, pesticidal residue, cigarettes, oil, rice flower rubber, paper, putty, inks, whiskey and paints are some of the materials analyzed by this method [50, 249]. The reaction (2.414 minutes half-life, and 1.78 MeV gamma energy ) was used to determine the aluminum content in coal [390], and in iron ores [384]. However, the production of by the thermal-neutron activation of via can interfere with the (n,p) reaction or the thermal activation of thermal-activation of Manganese-56 decays with a 2.58 hour halflife and emits 1.81 MeV gammas that may interfere with the 1.78 MeV of also emits 0.874 and 2.11 MeV gammas that can be easily
Elemental and Content Analysis
527
discriminated against. The effect of the reaction can be reduced by ensuring the use of a well-thermalized neutron field, but the interference of the reaction must be taken into consideration when detecting aluminum in manganese-rich iron ores. This can be via its 0.874 and achieved either by detecting the concentration of 2.11 MeV gammas or by waiting until decays, then measuring the strength of the 1.78 MeV gamma peak. While the reaction complicates the measurement of aluminum in manganese ores, it can be used for determining the manganese content. The decay of (2.5789 hour half-life) results in a number of gamma-rays, one of which is 2.113 MeV (14.3% yield) which can be used to detect manganese, while another one (1.81 MeV, 27.2% yield) can interfere with the 1.78 MeV resulting from the reaction, due to the presence of aluminum in the ore. Therefore, the contribution of derived from the 2.113 MeV peak must be first subtracted from the 1.81 MeV peak before the determination of aluminum concentration, to avoid any overlapping between these two closely spaced 1.81 and 1.78 MeV peaks [384] (unless of course a high-resolution detector is used). Thermal-activation analysis using moderated isotopic sources has been also used for determining the concentration of trace impurities in and in iron ore, and in tar sand, and minerals in coal) [552]. The technique was also used for the elemental analysis of a phosphate ore [539]. Reference [553] investigated the use of the technique for the detection of sodium and aluminum in “green liquor”, a mixture of sodium hydroxide and alumina dissolved in water present in the refining process of aluminum at the stage in which the liquor is supersaturated in aluminum prior to precipitation. Sodium can be detected by the gamma of its (1.368 and 2.754 MeV, 14.96 h half-life) (1.779 MeV, 2.25 min half-life). Activation can be achieved by and discrete sampling, where a neutron source is placed at the middle of a sample tank for a certain time then removed, allowing measurement of the activated gamma-rays after a certain decay time. Alternatively continuous sampling can be used by activating the sample in one tank and allowing the activated material to flow into another tank, shielded from the first, where radiation activity is detected. Epithermal-Neutron In – Delayed-Gamma Out. Epithermal neutrons are defined here as neutrons with energy above the cadmium cut-off energy of about 0.5 eV, and below about 1 MeV; an energy range that spans the cross-section resonances, when present. Lower energy neutrons are removed with cadmium filters (1 mm thick or so) and/or borated (boron-containing) materials. Exposure to higher-energy neu-
528
Radiation Probing, Gauging, Imaging and Analysis
trons can be reduced by slightly moderating the source neutrons. Epithermal neutron analysis is favored over thermal-neutron analysis when thermal-neutron absorbers are present, and to overcome interferences from elements emitting similar gamma-ray energies (such as and A number of reactions can be employed in epithermal-activation. Inelastic scattering, though has a lower cross-section, tends to produce nuclides with shorter half-lives (and consequently higher activity) and with lower energy (leading to higher detection efficiency), due to the formation of metastable isomeric states. For example, the reaction leads to the formation of which has a half-life of 42.6 min and produces a 158.30 keV gammas (52.3% yield) [12]. The same parameters for are 7.73 s, 279.00 keV (70.9%) and for are 67.2 min, 899.15 keV (99.17%). This enables fast determination of these elements. It also offers the ability to determine the lead content, since neutron absorption by natural lead produces stable nuclides, or a betaemitter The reaction can be used of for the detection of Br, Sr, Y, Cd, In, Ba, Hf, Os, Au, Hg, Pb, and has been used for rapid determination of Hg, Au and Pb. The transmutation (n,p) and reactions are particularly useful in dealing with interferences between elements, by producing nuclides with different emission characteristics. For example, Si can be activated with and reactions. This redundancy both the can be used to compensate for interferences from nuclides producing the and same activation produces; in this case In addition, some nuclides can only be activated by these reactions, such as O, P and Si. The elements O, F, Na, Mg, Al, Si, S, K, Ca, Ti, V, Fe, Co, Ni, Zn, Ge, As, Nb can be analyzed by the (n,p) reaction, and have been used for the analysis of rocks, pottery, plants, bones and reaction was also used to determine the glass [248]. The silicon concentration in iron and bauxite ores [384]. Epithermal-neutron activation by the reaction is suitable for the detection of Ni, Zn, As, Se, Br, Rb, Sr, Mo, Sb, Cs, Ba, Sm, Tb, Hf, Ta, W, Th, U; thus it has been used for the analysis of coal and fly ash and geological samples [248].
Fast-Neutron In – Prompt-Gamma Out. Since readily available sources emit fast-neutrons, efficient utilization of these sources requires their use directly without moderation or collimation; processes which lead to wastage of neutrons by absorption and divergence. Although, the activation cross-section generally decreases with increasing neutron energy, the direct use of a source enables in situ and on-line activation.
Elemental and Content Analysis
529
The lower activation cross-section can be compensated for by using intense neutron generators. Inelastic scattering is often the reaction of choice in fast-neutron activation. Elements that can be analyzed with this reaction are given in Table 8.6. This reaction has a threshold-energy of 5 MeV or more, see section 8.1.4.2. Therefore, 14-MeV neutron generators are the favored source for use in this technique. Nevertheless, the high-energy tail of the spectrum of neutrons emitted by isotopic sources has been used for this purpose. For example, a source (producing neutrons/s) was used [554, 555] for analyzing carbon coal by measuring the 4.439 MeV gamma associated with the inelastic scattering of fastThe low-energy tail of the spectrum, which is readily neutrons by further reduced in energy by slowing-down by the coal’s hydrogen, was also utilized to determine the hydrogen content of coal via the 2.223 MeV gamma associated with neutron-capture by hydrogen. Prompt-gamma activation analysis in coal exploration or in effluent has been also reported [556]. Some of the other elements analyzed by this method are Al and Si in soil and Cr and Ni in metals [256]. Fast-neutron activation using a 14 MeV neutron generator was also reported for in situ detection of carbon in soil [557]. Reference [558] studied 81 gamma-ray energies arising from the inelastic scattering of fast-neutrons produced by an by 21 elements commonly found in minerals; isotopic source reporting that with a source emitting neutrons/s, element concentration larger than 1% (weight) can be determined in samples weighing 10 to 100 kg. Fast-neutron activation is also used for the determination of carbon-to-oxygen ratio in oil reservoirs,. This ratio is a means of detecting and evaluating oil, since gas/light-oil zones have a low C/O ratio, while heavy oil has a high value [40]. Reference [559] reported the standardization of based probe for assessment of masonry by measuring the water and soluble salt (NaCl) via the prompt gamma-ray emitted form H and Cl. On-line control of raw-mill feed composition is a key factor in the improved control of cement plants. An elemental analyzer for a cement raw-mill feed on a conveyor belt was developed and tested successfully on highly segregated material with a depth range of 100 to 180 mm [560]. The device, based on neutron inelastic-scattering showed, under dynamic in-plant testing, analyzer total errors of 0.49, 0.52, 0.38 and 0.23 weight percent for CaO, and respectively, over 10 minute counting periods. Analysis, on-line, of hot reduced iron ores was also performed by inelastic-scattering, using an neutron source [555, 561]. The iron, oxygen, carbon and silica contents of the ore were determined using the neutron inelastic scattering gamma-rays
530
Radiation Probing, Gauging, Imaging and Analysis
at 0.85, 6.13, 4.43 and 1.78 MeV, respectively, to within 2.2 , 0.6 , 0.5, 1.0 % (weight), respectively. Fast-neutron activation analysis using inelastic gamma-rays has been also considered for the detection of contraband materials in passenger luggage [562, 563, 564] and cargo containers [565]. Of particular interest is the detection of explosive materials and narcotics. Detection of nitrogen-based explosives requires the determination of the relative ratio of the concentration of N, O , C and H [566]. For narcotics, the detection of chlorine is also needed. The characteristic gamma-rays from the reaction utilized for this purpose are: 4.439 MeV for 2.31, 1.64 and 0.72 MeV for 6.13 MeV for 1.22,1.76, 2.65, 2.69, 3.16 for and 3.09, 3.10 MeV for Hydrogen is not detectable by fast-neutron activation. However, fast-neutrons incident on the object will be slowed-down by the hydrogen that may be present, enabling the detection of H by thermal-neutron activation. In order to reduce the background signal produced by the activation of surrounding material, reference [562] suggested the use of pulsed neutrons, of an energy not exceeding 8 MeV, and monitoring the gamma-rays associated with the elements of interest within a short period following the pulse. By closing the detection window when the source neutrons activate the surrounding shielding and structural material, the background component is greatly reduced. With the detector collimated to view a small volume along the direction of the incident neutron beam, the density of and in that voxel can be determined. In the work of reference [565], a pulsed (30 bursts) 14 MeV neutron generator was employed. In addition to the inelastic gamma-radiation collected during the duration of the pulse, gamma-rays emitted between the bursts are also measured as it provides an indication of the thermal-capture of neutrons within the inspected cargo, assuming that the cargo contains sufficient neutron slowing-down material. The inelastic fast-neutron-induced gamma-rays are used to determine the C/O ratio within the inspected voxel, while the thermal-neutron capture gamma is used to determine the Cl/H ratio. These ratios are sufficient to distinguish narcotics from other innocuous materials. Reference [567] discussed the physical factors affecting this pulsed fast-neutron analysis (PFNA) technique. These include the attenuation of incident neutrons as they penetrate matter and the associated neutron scattering, which expands the size of the activated volume. The application of PFNA to drug and explosive detection in cargo containers is discussed in references [568] and [569]. The fast-neutron activation technique is also useful for detecting the presence of chemical weapons and special nuclear materials in cargo and trucks [570, 571]. Reference [572] suggested also the use of the technique,
Elemental and Content Analysis
531
with a source, to determine the composition of space (e.g. Lunar) bodies. The PFNA concept is further extended by detecting, not only the prompt gammas from inelastic-scattering and thermal-neutron activation reactions, but also the delayed-neutrons from the reactions: and (n,p), etc. [573]. While prompt-capture gamma-rays are detected between neutron pulses, during which inelastic gamma-rays are measured, every few hundred pulses the neutron beam is turned off for a few millisecond, to allow for the detection of delayed-gamma emissions. While inelastic prompt-gammas enable the detection of elements such as C, N and O, and prompt-gamma capture identifies H, N, Cl and Fe, delayed-neutron activation is useful for measuring the concentration of O, Si, F and P. The field-of-view, defined by the collimation of gamma-ray detectors, determines the volume from which gamma-rays are emitted. This multi-mode analysis makes the technique suitable for a variety of applications, including: contraband detection [574] (explosives [575, 576] and narcotics [577] ), and on-line elemental analysis of coal and cement [578, 579, 580, 581]. This technique is often refereed to as PELAN (Pulsed Elemental Analysis with Neutrons). An alternative to the use of pulsed neutrons is to time-tag emitted neutrons as well as emitted photons [582], using the alpha-particle associated with neutrons produced by the reaction, (see section 2.3.1.3). In this reaction, in addition to the 14 MeV produced, an alpha-particle emerges in the opposite direction carrying an energy of 3.5 MeV. In a specially designed neutron generator, the emitted alphaparticles, detected using a position-sensitive detector, can be used to tag the direction of the emitted neutrons, which has to be traveling in the opposite direction and originating from the target. At 14 MeV, the emitted neutrons will travel at a speed of about 0.05 m/ns, while the emitted inelastic gamma-rays travel at the speed of light (about 0.30 m/ns). Therefore, using the measured time of emission of the neutron (by its associated alpha-particle) and the time of arrival of the emitted inelastic gamma-rays, along with the direction of the incident neutron, the position of emission of the inelastic gamma-ray from the target can be determined [583, 584]. The time-of-flight, therefore, can be “gated” to probe a particular position (range) within the interrogated object [585], thus enhancing the signal-to-noise ratio by eliminating the detection of emission from outside the range. The energy of the emitted inelastic gamma-rays, as discussed in section 8.1.4.2, can be used to identify the emitting elements. Therefore, an element-by-element image of the target can be obtained. The spectra of the gamma-rays resulting from neutron inelastic-scattering reactions can be used to identify ele-
532
Radiation Probing, Gauging, Imaging and Analysis
ments associated with chemicals in chemical warfare agents, explosives, and narcotics, as well as many pollutants and fissile and fertile nuclear materials [583, 586]. This combined associated-particle, neutron timeof-flight, and inelastic gamma-ray spectroscopy method was also used to investigate the caloric value of coal by measuring its carbon content and even the coal’s via the 4.439 MeV of the reaction with sulphur content via its 1.79, 2.77, 2.23 MeV gammas [585]. The same reference reported the use of the technique to assay the kerogen (organic component) and silicon (from quartz) content and in oil shales; with the latter determined using its 1.779 MeV inelastic gamma [564]). This probing technique was also proposed for detecting drugs, via their carbon and oxygen content, and explosive materials through their nitrogen, oxygen and carbon content [585]. Inelastic scattering with a radioisotope is also used for determining the contents of munition, by the inelastic gamma-ray rays from As, B, Ca, Cl, Fe, H, K, Na, P, S, Ti and Zn [587]. A portable system, known as PINS (portable isotopic neutron spectroscopy) is used by the US Army to detect, among other things, artillery shells and chemicalweapon containers (such as mustard gas) [588]. Pulsed neutrons generated by the interaction of high-energy photons (resulting from the bremsstrahlung radiation of a 6.5 MeV electron accelerator) were also used for elemental analysis by monitoring the gamma-ray emitted as soon as after each bremsstrahlung pulse [589]. Fast-Neutron In – Delayed-Gamma Out. A number of applications have taken advantage of the favorable conditions of delayed-gamma emission analysis, i.e. the ability to prolong irradiation time and perform measurements off-line in a low-background environment, combined with the capability to directly employ a neutron source in situ without the bulky configuration associated with moderated assemblies. Cyclic analysis can also be used with delayed-gamma analysis, to enhance the activation process for short-lived activation products. With a pulsed neutron generator, cycling can be achieved by repeated pulsing. The material content of elements listed in Table 8.5 can be detected by this method, enabling the analysis of metal alloys, minerals, oil, lubricants, and other organic materials. Reference [243] discussed many of the applications of this technique. Oxygen, an element that is difficult to measure by other methods, is wellsuited for fast-neutron activation, via the reaction. Since oxygen is not activated below 9.63 MeV neutron energy, a 14 MeV neutron generator is required. The high energy of emitted photons (6.13 MeV) makes it possible to study oxygen content in metals: steel,
Elemental and Content Analysis
533
titanium, aluminum, beryllium, copper, iron, nickel, chromium, zirconium, tantalum, molybdenum, niobium and cesium. The technique has also been used for the measurement of oxygen content in rocks and organic compounds. Reference [590] reported the use of this reaction to determine the amount of oxygen that may be present in Li-Si alloys in thermally-activated batteries. If air or water is introthe form of duced into the battery, it dioxides the lithium, degrading the battery’s performance [590]. Oxygen activation has also been used to detect water flow in producing and injection wells, to ensure that oil and gas production does not contaminate potable water supplies [323, 591]. Nitrogen can also be measured, via the positron-emitting reaction-product, if it is present in significant quantities, such as in plant materials (e.g. grain products), explosives and propellants, and rubber and fertilizers. Aluminum is also one of the elements that are quite amenable to fastneutron activation, particularly by the 0.84 MeV of the activation product (9.458 min, half-life), and thus the reaction was used for determining the aluminum concentration in bauxite and coal samples [384]. Some other reported applications include the determination of aluminum content in aircraft hydraulic systems (caused by metallic wear) and in engine oil, measurement of aluminum in composite propellants containing ammonium perchlorate, in minerals on the ocean bottom, and in copper and steel alloys. Copper is another element analyzed by this technique, as its activation produces the positron emitter Therefore, copper content in lubricating oils, ores, and brass alloys has been determined by this technique. The most abundant isotope of iron, a unique identifier of when activated by fast-neutrons produces iron. This is used for measuring iron in oil additives, hydraulic fluids, ocean-floor sediments and in bituminous coal samples. Neutron In – Charged-Particle Out. Neutron-absorption can lead to the production of charged-particles, via the or (n,p) reactions. Usually, the decay of the reaction products by gamma-emission is what is utilized in elemental applications. However, in some cases the emitted charged-particles themselves are detected and used to study the depth profile of the neutron-absorbing material. As indicated in section 8.5.2, this techniques requires a high neutron-flux to produce a high level of sensitivity, thus demands a neutron beam extracted from a nuclear reactor. Because of the short range of emitted charged-particles, the technique is limited to studying thin layers and films or in near-surface analysis (by detecting backscattered particles). The sample and the detector must also be enclosed within a vacuum chamber for charged-particles to maintain their energy of emission. The main elements studied by this
534
Radiation Probing, Gauging, Imaging and Analysis
technique are and other elements are listed in Table 8.10. The main application of this technique is in analyzing boron content in semiconductor wafers, borophosphislicate glass and insulators of integrated circuits [264]. Boron is used as a doping material in microelectronic materials, and this technique enables studying the boron concentration and distribution. The method is also used to study the thickness of the boron layer in borophosphislicate glass, deposited as an insulating layer on dense integrated circuits. The technique has been employed for studying the distribution of light elements implanted in heavy matrix materials, such as Li in Nb, He in Nb and Mo [592]. Thermal-Neutron In – Neutrons Out. Neutron fission is the most obvious manifestation of a neutron producing more neutrons by activating, or in effect splitting, the target nucleus into many radioactive fragments. This process can be used for the detection of thorium, uranium and plutonium, by monitoring the delayed-neutrons emitted as a result of the decay of fission products, as explained in section 8.6.3. Thermalneutrons cause fission in both and while fast-neutrons cause fission in and Therefore, thermal-neutrons can be used to determine the concentration of which in natural materials is a direct indication of the total uranium content. Then, if this natural material, such as a geological sample, is exposed to a fast-neutron can be source, the amount of delayed-neutron emission caused by This method of calculated, with the excess count attributed to double irradiation is more readily accomplished by exposing the material first to a mixed source of thermal and fast neutrons, then to epithermal neutrons obtained by covering the material with cadmium or boron. The first exposure provides an indication of the total content of all fissionable materials, and the second exposure gives only the content of elements that are fissionable by fast-neutrons. This method is used for determining the to ratio in enriched or depleted uranium, the uranium-to-plutonium ratio in mixtures and in irradiated nuclear fuel [265]. Reference [593] described a system for measuring the content of fissile elements (in particular and in spent (irradiated) fuel rods of a light-water breeder reactor that utilized a (binary) fuel. A source was used to induce fission in the fuel rod. The source was surrounded with nickel metal (which has a high macroscopic elasticscattering cross-section) and moderated with polyethylene. An In/Cd foil was used to remove low-energy neutrons, since faster neutrons are less susceptible to self-attenuation within the fuel than slower neutrons.
Elemental and Content Analysis
535
Nevertheless, neutron-absorption within an interrogated fuel rod is compensated for by measuring the transmission of source neutrons within the rod, using a (miniature) fission counter (see section 4.4.1.3) to obtain an absorption indication similar to that provided by the fissile material in the fuel, shielded from the gamma-rays of the irradiated fuel with a lead shield. After activation, the rod is removed from the source region and the amount of delayed-neutrons resulting from fission are counted, using a proportional counter. The concentration of the fission products is measured by monitoring its gamma-emission energy (662 keV), using a collimated HPGe detector (see section 4.3.3), and the measured concentration is used to correct for neutron absorption by the fuel’s fission products. Delayed-neutron emission can also be used in principle for the measurement of and by the delayed-neutron precursors (178.3 ms) and (4.175 s half-life). Both the and by fast-neutrons (above 8.2 MeV reactions produce for the former reaction and above 10.5 MeV for the latter). However, can be due to the double reaction: folproduction of lowed by which is caused by thermal-neutron absorption. but the very short halfLithium-9 is produced by the reaction life of makes it difficult to detect with delayed-neutron analysis. Delayed-neutron activation has, however, been used for determining the oxygen and lithium content [265]. Emitted delayed-neutrons are fast-neutrons, but their detection is usually performed with thermal-neutron detectors covered with a moderated material, to increase the detection efficiency. Since neutron exposure can also lead to the release of gamma-rays by activating some elements in the sample, detectors that are not too sensitive to gamma-rays, such and detectors, are employed; preferably shielded by a lead as sleeve to further reduce gamma exposure. To detect delayed-neutrons, the inspected object has to be removed from direct exposure to source neutrons. This can be done by transferring the object out of the exposure zone, or applying a burst (pulse) or neutrons.
Non-thermal Neutron In - Fission-Neutrons Out. Fissionneutrons can also be distinguished, from incident slower neutrons, by their energy, as fission-neutrons have higher energy (2 MeV average energy, 0.72 MeV most probable energy). This process was used for the using, a photoneutron assay of fissile materials, particularly source. Either a or a photon source can be employed, along with a beryllium target, to produce relatively low-energy neutrons (see source, the average energy of the emitted section 2.17). For an
536
Radiation Probing, Gauging, Imaging and Analysis
neurons is 26 keV and 4% of the neutrons are produced at a maximum source produces neutrons of an energy of about 360 keV, while a average energy of about 200 keV. The neutron energies of either sources are below the 1.2 MeV threshold-energy for fission of Therefore, source can be used for the detection of the neutrons of an which undergoes fission at any energy, in a fuel containing and such as an enriched or natural uranium. Reference [594] presented an assembly for use in the assay of reactor fuel rods and small samples of fissile material. This cylindrical assembly had a central hole within which a test sample is introduced. The central test channel is lined with cadmium to remove any thermal-neutrons that may reach the test object. The hole is surrounded with a beryllium layer (14 mm thick) within sources are located at two opposite sides of the sample which two for symmetric irradiation. The beryllium core is surrounded by nickel or titanium (20 to 30 mm), which act as filters (see section 6.46) that selectively reflect (by elastic scattering) source neutrons 26 keV) back to the test channel, while absorbing low-energy thermal-neutrons. The higher energy fission-neutrons are transmitted through towards detectors, assembled radially behind the filter layer. These detectors are source, shielded by lead (70 mm thick) from the gamma-rays of the and those of irradiated fuel rods. A 50 mm layer of iron was used as a reflector around the detector, to increase their count rate by redirecting the neutrons back towards the detectors. The entire assembly was shielded with a borated paraffin shield (about 145 mm thick). The uranium concentration in geological formation was also measured by inducing fission with a neutron source, by the fast-neutron and the thermal-neutron fission of The delayed neufission of trons accompanying the fission process are detected, after their slowingdown, and are distinguished from the source neutrons by their timedelay [595, 596, 597]. Alternatively, prompt fission-neutrons can be detected after they are slowed-down in the formation following the issuing of a pulse of neutrons from a neutron generator [595, 598]. The thermalneutron count rate in the delayed-neutron time-frame (i.e. following the decay of the source pulse) was shown to be greater in the presence of uranium [595]. The die-away time of fast/epithermal neutrons was also shown to be longer in the presence of uranium, that is, the neutron density decreases more slowly due to the production of fast-neutrons by fission [595]. The intensity of the detected fast and epithermal neutrons, following the issuing of the neutron pulse was shown to be directly proportional to the uranium grade (weight per cent). Another application of die-away is determining the degree of purity of graphite, since
Elemental and Content Analysis
537
neutron-absorbing impurities affect the decay-constant of the neutron pulse [599]. Fission induced by a neutron source, such as is used to detect the presence of plutonium in containers [600, 601], when the amount of fissile material is too small to produce sufficient spontaneous-fission and gamma-rays to permit passive assay (see section 12.1.2). The “shuffler” technique is used for this purpose, where a source is placed near the material to be inspected then quickly withdrawn. Delayed-neutron counting is then used to detect the presence and amount of fissile material [602, 603, 604, 605, 606]. The same concept is used to assess the criticality of fissile systems by source-driven noise analysis, since a small change in the fissile system affects the amount of fission introduced by the source and consequently the amount of delayed-neutrons and associated neutron noise after the withdrawal of the source [607]. Neutrons emitted from the spontaneous fission source can be time-tagged by monitoring the fission fragments associated with neutron emission. Such timing information is useful for distinguishing between source neutrons transmitted without interactions in the object and those scattered within the object, or generated by fission if the object contains a fissionable material. This concept is used in a system for nuclear weapon detection, which also analyzed gamma-emissions with time and frequency [608]. A similar approach was used to characterize large uranyl fluoride deposits on the pipes of a former uranium enrichment (gaseous diffusion) plant [609]. Analysis of neutron induced by a source in a subcritical assembly was also used to measure reactivity (degree of subcriticality) of assemblies. [610, 611, 612, 613, 614, 615]. Coincidence measurement of fission neutrons and gamma-rays, induced by an external of neutrons, is also used in fissile-material assaying [616].
12.1.1.2
Photon Activation
Photon In – Photon Out. In spite of the low cross-section of photonuclear reactions, and the fact that they requires the use of a highenergy electron accelerators to produce high-energy photons (tens of MeV’s), photon-activation analysis is particularly competitive over other analysis methods for the following elements: Na, Mg, Ti, V, Cr, Mn, Fe, Co, Zr, Y and Pb [617], see Table 8.9. It is also suited for O, C, N and F. Since photons offer good penetrability, the method can be used for bulk analysis of large objects. The emission of photons is usually the result of the decay of a reaction product, but photoexciation, the reaction,
538
Radiation Probing, Gauging, Imaging and Analysis
is also possible, though not as useful as the other emission mechanisms for elemental determination. The application of photon activation analysis spans many fields. A comprehensive list of applications is given in reference [258], classified as environmental, biological, geological, industrial, archaeological and forensic. Reference [259] mentioned a number of applications. Multielemental analysis of garden soil, rocks, deep-sea sediments, and atmospheric particulate material was performed with this technique. Photon activation was employed for the detection of light-elements in high-purity metals and semiconductor material. Carbon and nitrogen contents in iron, cobalt and chromium, were also measured with the technique. Other detected elements include iodine in soil, nickel in geological material, carbon and trace elements in coal, and selenium in animal feed stuffs. Reference [259] also reported the use of photon activation to measure the protein content of cereals and vegetables. The technique was also used to analyze the composition of medieval iron-based sword and helmet using 30 MeV and 16 MeV bremsstrahlung radiation [406]. Photon-activation was also used in the assay of fission products in spent nuclear fuel assemblies, by the excitation of the fission product to its 4.5 h half-life metastable state and the subsequent counting of the 336 keV transition energy [618]. The gamma-rays (above 1.078 MeV) inducing activation are produced by the decay of the relatively long-lived fission products and Photon In – Neutron Out. Neutron emission by photon-activation can be either prompt or delayed, as discussed in section 8.6.1. Both techniques are suited for the analysis of and The ability to generate prompt neutrons at reasonably low photon-energies from interactions with make it feasible to detect deuterium and beryllium with isotopic sources, with photon energies above 1.67 MeV and 2.33 MeV, respectively. In the case of beryllium, being a solid, the reaction is used as a source of neutrons, see Table 2.17, while photon interactions with deuterium in nuclear reactors (such as CANDU reactors) present an additional source of reactivity. In NDE applications, the radioisotopic sources (2.754 MeV, 99.94% yield) and (2.091 MeV, 5.51% yield) can both be used for detecting while the former is required for detecting In the presence of both elements simultaneously, can be used first to measure the content, and a source is used to measure the total content of both elements. Using photons from a source, the concentration of heavy water in light water [619], and in soil moisture [619, 620], was determined by measuring the neutrons produced via
Elemental and Content Analysis
539
the reaction The same process was used to monitor tritiated water, using as a tag [621]. In addition to these isotopic sources, accelerators can be used to provide a higher photon flux, and hence lower detection limits [259]. Reference [26] suggested the use of the 6.13 and 7.12 MeV gamma-rays produced by the decay of (see section 2.2.4) to detect fissile materials (by the induced photofission [622]), as well as and (considered special nuclear materials) by the reaction. A similar approach is described in reference [623], using a transposable electron accelerator producing 6, 9 and 8 MeV pulsed electron beams (with a pulse duration). repetition rate between 10 to 300 Hz and a 4.5 Another application of photoneutron emission is in the detection of and [624]. Photofisthe fissionable elements: sion occurs when these elements are bombarded by high-energy photos, resulting in a neutron yield much higher than the photoneutron production by other elements. This makes it possible to detect these elements even if they are embedded within another material (as in the case of nuclear waste casks) or encased within cladding (as in the case of fuel rods) [259]. However, the need to use photons of energy in excess of 5 MeV, makes it necessary to employ an accelerator. The penetrability of both incident photons and the fission fast-neutrons makes it also possible to analyze a large volume of material. The analysis of these elements can either be done by monitoring the prompt emission of neutrons by the reaction and by the subsequent fission introduced by the resulting neutrons, or by monitoring the delayed neutrons resulting from the decay of fission produces. In prompt analysis, the background neutron count rate can be high due to neutron production by the reaction with other elements in the inspected object, or with the surrounding shielding and structure material. Delayed-neutron analysis reduces this background signal and can be accomplished by simply turning off the photon-producing accelerator. Neutrons from the photoneutron reaction may also be used to induce neutron activation. For example, by introducing a beryllium photoneutron converter into spent-fuel assemblies, neutrons will be produced by photons from the decay of fission products which emit photons with an energy greater than 1.67 MeV. This mechanism was used to assay spent nuclear fuel assemblies for these fission products by neutron activation of the fission product producing that decays with a 54.1 min giving 417, 1097, 1293 and 2112 keV decay gamma-rays [618]. Delayed-neutron emission, following photon-activation, is also useful for the detection of boron, oxygen and fluorine by the production of the fast-decaying (about 1 s half-life) neutron emitters and as
540
Radiation Probing, Gauging, Imaging and Analysis
explained in section 8.6.1. The short half-life of the these isotopes enables on-line detection of these elements [259]. Also the high energy of incident photons and emitted neutrons makes it possible to analyze an entire object, rather than a small sample of material. The reaction (16.3 MeV threshold-energy) can be used to measure the concentration of by monitoring the delayed-neutrons emitted from the (15.7 MeV threshold-energy) is also useful for latter. The measuring the concentration of by monitoring the 511 keV gamma(a positron emitter, 122.24 s halfrays associated with the decay of life). These two reactions were used for measuring the isotopic concentration ratios of these two oxygen isotopes [625]. The isotope is also useful as a radiotracer for studying the deposition of oxygen. The reaction can be used for measuring the nitrogen concentration, hence the detection of nitrogen-rich explosives [626, 627]. The product isotope, is a positron emitter, with a half-life of 9.97 minutes [13]. The positrons are annihilated by the surrounding electrons of the medium, producing two 511 keV photons emitted into opposite directions. The intensity of these photons is a direct indication of the nitrogen concentration in the material within which is produced. The production of this isotope requires photons of energy of at least 13.5 MeV, which can be produced with a linear accelerator [627]. At this energy, not too many other elements produce positrons, or if produced would have very short or very long half-life. Note also that other positron emitting isotopes can be produced by photon activation: at at and at where is the gamma-ray energy [628]. Although the emitted photoneutrons are fast-neutrons, a thermaldetector, can be used for their detecneutron detector, such as the tion, in spite of its low efficiency, as it is less sensitive than other types of neutron detectors to gamma-rays (see section 4.4). Another approach to neutron detection, particularly suited for this application, is to use a manganese bath to slow-down neutrons and hence increase their crossThe many gamma-rays (ranging section for the reaction in energy from 26.6 keV to 7.4 MeV [12]) emitted by the decay of (2.58 h, half-life) can then be detected with a Na(I) detector [259]. This allows the detection of prompt-neutrons after the source is turned-off, which in turn reduces the effect of source photons and the associated background signal produced by photon scattering in the surroundings.
Photon In – Charged-Particle Out. As indicated in section 8.5, on one hand a high photon-energy is required to induce charged-particles; on the other hand, charged-particles have limited penetrability in mat-
Elemental and Content Analysis
541
ter. The latter fact necessitates the use of thin objects, to allow emitted particles to escape. However, for such a thin object, high-energy photons would hardly interact. Therefore, this interaction modality is not quite useful for elemental analysis, except when high-energy beta-emitters or positrons are produced. However, the technique has been used to measure the concentration of lithium, beryllium and sulfur. The three useful reactions in this regard, as indicated in section 8.5 are: (beta, 3.51 MeV, 0.81 s half-life), (beta, 13 MeV, 0.84 s), and (positron, 4.39 MeV, 2.56 s); where the values in brackets indicate, respectively, the type of particle emitted, its maximum positron energy and the half-life of its originating nucleus. The high energy of emitted particles and their low mass enables them to penetrate thicker objects. The increased thickness also enhances the probability of interaction of the incident high-energy photons. However, the short half-life of the isotopes resulting from these photonuclear reactions necessitates the use of a very rapid mechanism to remove the object, and isolate it, for subsequent delayed-emission analysis. Although these short half-lives makes it possible in principle to perform on-line analysis, the high-energy of incident photons (above 12 MeV) can overwhelm the detection system, since high-energy electrons are produced by the Compton scattering of these photons with the surrounding material. At higher photon energy is produced by the photon activation of Boron-12 (> 50 MeV), has a half life of 20 ms and decays by emitting high-energy electrons. The bremsstrahlung radiation associated with these electrons may be used to detect nitrogen, say in explosives
12.1.1.3
Charged-Particle Activation
The poor penetrability of charged-particles limits their use to nearsurface analysis. On the other hand, their unique feature of losing energy continuously provides them with the ability to determine the spatial distribution of element concentration, i.e. depth profiling. Some specific applications are discussed below. Charged-Particle In – Charged-Particle Out.
As discussed in
section 8.5.3, the energy of emitted charged-particles, for a given source energy, not only indicates whether a particular reaction has taken place, but also it uniquely determines the direction of emission, hence the location of scattering, Eq. (8.9). Therefore, charged-particle spectrometry has been used to measure the distribution of a number of light elements implanted in a heavier matrix material [257]. This analysis has, however, to be performed in vacuum, so that the detected charged-particles do not lose energy after emission from the inspected object. Table 8.11
542
Radiation Probing, Gauging, Imaging and Analysis
lists some of the useful reactions for this technique. The depth profile of hydrogen, deuterium, or helium implanted in metals, was measured with this reaction. Other depth-profile measurements include those of beryllium in nickel alloys, boron in semiconductor (silicon) wafers and glass, and carbon in tantalum carbide films, thin plastic sheets, and organic materials. The depth profile of nitrogen in glass, silicon wafers, steel, organic materials (such as seeds) and human tooth dentine, was also measured with this reaction. The positrons arising from the decay of (66 s, half-life), with the latter produced by the reaction was used to determine the nitrogen content in diamond [629]. The distribution of oxygen in a metal is determined by the reaction since the proton reaction with is endoergic. (0.20%) is compensated for by the The low natural abundance of reactively high cross-section of the reaction for incident protons of energy in the range of 600 to 800 keV. This method is used to examine the oxygen profile in niobium and in steel exposed to moist carbon dioxide Reference [630] reported the use of this reaction, with labeled with as a tracer, to measure the oxygen profile in rutile and sapphire. Most commonly though, a deuteron beam is used for analysis, either with the (d,p) or the reactions, both are exoergic reactions, but the (d,p) reaction is preferred because of the longer range of protons. Therefore, the (n,p) reaction with was utilized for determining the oxygen distribution in silicon wafers and tooth enamel. The reactions and were also used to study the oxygen profile, in particular in the analysis of pellets exposed to a leachant comparable to thermal granite ground water [630]. The distribution of heavy elements embedded in a matrix of other heavy elements has also been studied with charged-particle spectroscopy. Reference [257] reported the determination of the profiles of silicon in metals, chromium in thin layers on metal substrate, and nickel on substrates of metal (copper), while reference [630] discussed the use of the technique for investigating the carbon content of ceramic substrates utilized in high-performance packaging technology, the sulfur diffusion in bulk CdTe and CdTe/CdSi thin-film hetrojunction solar cells, and the silicon diffusion from a thin Si film into polycrystalline gold foils. The reaction induced by 3 MeV ions, was used to detect carbon impurities introduced in the manufacturing of HgCdMnTe semiconductors; is a positron emitter with a 20.38 min half-life [631]. The reaction also takes place, enabling the detection of the oxygen concentration by the annihilation of the positrons emitted by the decay of with a 109.72 min half-life.
Elemental and Content Analysis
543
The superb selectivity and high counting efficiency of coincidence measurement of the two reaction products emitted by charged-particle activation, see section 8.5.3, is particularly useful for detecting trace or small amounts of elements. The method has been used for the determination of trace amounts of hydrogen in aluminum, titanium, uranium and in polyester plastics films [257]. The selectivity of the coincide method makes it also attractive for the isotopic composition determination of lithium and boron [257]. The reaction is utilized in an alpha-proton-x-ray spectrometer (APXs) to analyze in situ the composition of the surface of Mars in the Pathfinder mission [632, 633, 634] and in the Surveyor lunar missions [635], see section 12.1.5. The reactions provided data on light elements (carbon to iron), while the x-rays (produced as a result of atomic excitation by the alpha-source) enables the detection of elements heavier than silicon. Charged-Particle In – Photon Out. This method is often referred to as PIGME, for particle-induced gamma emission. Some elements that can be detected by this technique are given in Table 8.7, and many others are cataloged in reference [257]. The limited range of incident charged-particles makes it possible to confine elemental analysis to near the surface of an object. This makes the technique particularly useful for analyzing small samples, or for studying the distribution of elements implanted in metals to improve their surface quality. The method can monitor either the gamma-rays promptly emitted with the activation reaction or the delayed photons produced as the activation products decay. The former method is known as PIPPS (particle-induced prompt photon spectrometry), as it involves measuring the energy of the emitted gamma-rays to identify the characteristic emission of the elements of interest. The prompt gamma-emission method has been used in many applications [257]. Fluorine was measured in glass, air, cement ores and food samples. Sulfur in coal, magnesium in vegetation, beryllium in air-born dust and in boron carbide, were also measured with the technique. The method was also used for determining the elemental content of chalcogenide glasses (S, As, Ge and Te), and for analyzing archeological artifacts for B, F, Na, Mg, Al, Si, Cu. Geological samples were also analyzed for Li, F, Na, Mg, Al, Ti, Mn and Te. The C, O, Si, Cr, Co, V and Mo content of in steel and the B, Li, F, Na content of niobium was also evaluated. The method was also used for the isotopic analysis of enriched boron. Delayed gamma-emission is mainly used for the detection of light elements (B, C, N and O) in metals and semiconductor materials [255].
544
Radiation Probing, Gauging, Imaging and Analysis
Charged-Particle In – Neutron out. This technique is suitable for measuring light elements: Li, B, C, N, Ca and O. Neutron mission by charged-particle activation has been also used in some applications, in spite of the relatively complex process of measuring the spectrum of neutrons [257]. The technique has been used for the measurement of deuterium concentration in gases (housed in a thin nickel window). Nitrogen in gases and steel, and oxygen in gases and metals, were also measured. The isotopic content of calcium enriched with or were also determined by this method. In the case of oxygen, it can The threshold energy for be measured via the reaction this reaction is only 0.6992 MeV, allowing the use of one of the isotopic sources listed in Table 2.1. Reference [257] reported the utilization of a source for this purpose. Note also that the Be reaction is commonly employed in neutron sources (see section 2.3), because of the low coulomb barrier of beryllium. Therefore, beryllium can be readily detected with the reaction, using either an isotopic source or a ion beam.
12.1.2.
Passive Emission
As indicated in section 8.8.2, radioactive isotopes in a nuclear materials and radioactive waste are identified by their emitted characteristic gamma-rays. Gamma spectroscopy is routinely used for this purpose in nuclear facilities and in nuclear-weapons verification. Radiation emission is also used for detecting tritium in air [636], water [637] and aqueous solutions [638] of nuclear power plants employing heavy water as a coolant, by detecting the beta-rays (18 keV maximum energy) emitted from the decay of (12.3 year, half-life); produced by neutron-absorption by the deuterium of heavy water. Natural emission of radiation is also used in well-logging. Below the surface of the Earth, gamma activity is high in oil-bearing shales, medium for sand, and low for dense carbonates and anhydrites. Naturalradioactivity logs are, therefore, used to locate oil and natural gas. This can be done either by measuring the total radioactivity, including all sources of natural radiation, or by performing gamma-ray spectroscopy to determine the content of U, Th or the U/Th ratio. As indicated in section 8.8.2, the high penetrability of gamma-rays makes them more suited than charged-particles (alpha and beta particles) for use in applications involved large objects, such as the surroundings of a borehole. At any rate, alpha and beta natural emissions are quite weak to be of a practical use in well-logging. The well-logging device for natural emission is simply a photon detector, housed in a steel casing to protect it against hydrostatic pressure.
Elemental and Content Analysis
545
The detector can be hanged by a cable in wireline arrangement, or incorporated into the drill pipe to perform measurements while a well is drilled. In either case, measurements can be stored in a computer chip and sent to the surface through telemetry. Any of the gamma-ray detectors described in chapter 4 can be used for this purpose. However, scintillator detectors have the advantage of high efficiency, which makes it possible to use smaller detectors. In well-logging, a small detector provides a smaller vertical spatial resolution, as it enables the recordings of more measurement points in the log as the tool is driven down a borehole. Geiger-Müller tubes, though less sensitive than scintillators, and have a slower response-time, are inexpensive and simple to operate (as they produce large pulses, and as such require no amplification), but typically large-size tubes are required. Ionization-chambers are large in size and less efficient than scintillation detectors, but are relatively simple since their charge-carriers are collected directly, without the use of fragile photomultiplier tubes as is the case with scintillators. The count rate of a well-logging tool measuring the total natural radioactivity can be modeled as [40]:
where C is the total measurable gamma-radiation signal, is the bulk density of the formation in which the borehole is drilled, is the density of the radioactive mineral or element present in the formation at and is an activity factor characterizing the ravolume fraction dioactivity of mineral or element The model of Eq. (12.1) reflects the fact that the gamma-count rate will depend on the concentration of the radioactive material in the medium, i.e. to the summation of the density of the individual radioactive isotopes However, the density of since the activity per unit each isotope is weighted by the factor, weight of one isotope is different from the others. The factor is typically given relative to the gamma-ray activity per unit weight of where the subscript refers to the element involved. Subsequently, for thorium, [40]. In spite and for uranium of its low relative contribution, contributes significantly (typically about 50%) to the gamma count, as it is more abundant than thorium (28%) and uranium (24%). The bulk density of the formation, is included in the model of Eq. (12.1) to account for the fact that the emitted radiation signal is modified by absorption by the material of the formation. Therefore, a radioactive material present at a certain abundance in a dense formation would give rise to a radiation count lower than that obtained for the same abundance in a lighter formation.
546
Radiation Probing, Gauging, Imaging and Analysis
The measurement model of Eq. (12.1) indicates that, if the total count rate is measured (giving only one piece of information), neither the nature of the active elements nor their relative contribution can be determined. However, the overall level of activity is indicative of shaliness, since shales are the most common radioactive rocks. When the energy spectrum of emitted radiation is measured, typically using a scintillation detector, such NaI(Tl), the intensity of emissions from and the daughters of can be quantified. Since rocks year of age or older are considered to be in secular equilibrium, see section 3.7, the concentration of all members of the decay series of thorium or uranium can be calculated, if the concentration of one of the members of the decay series is measured. Therefore, it is sufficient to measure the at 2.62 MeV concentration of one of the daughters of thorium gamma) and one of the daughters of at 1.76 MeV gamma), see section 8.8.2. Potassium-40 is detected by its unique gamma-emission at 1.46 MeV. Therefore, typically the radiation intensity corresponding to these three energy bins are used to calculate the concentration of the corresponding elements. However, a certain energy bin corresponding to one isotopes is also sensitive to the presence of other isotopes, due to the emission and subsequent scattering within the detector of photons by other daughters isotopes of thorium and uranium. Therefore, the count rate, at an energy bin is generally expressed as [40]:
where and are coefficients for energy bin obtained from calibration. Calibration is initially performed in a special pit containing known concentrations of the three radioactive elements, potassium, thorium and uranium. In the field, a block of material of known concentration of radioactivity (such as monazite) is used to check and adjust the positioning of the energy bins of the spectrum [40]. More than three energy bins can also be monitored, including bins at lower energies (resulting from Compton scattering of higher energy photons within the detector, as well as from lower energy emissions from the daughters of and This also helps reduce the effect of the detector’s escape peaks, resulting from pair-production interactions in the detector (see section 4.3). The use of additional energy bins overdetermines the problem, enabling a least-squares solution that minimizes the effect of statistical variations on the measurements. This is particularly helpful in spectroscopy measurements at lower count rates. Many spectrum measurements can be obtained as a detector is lowered into a borehole. It is then desirable to filter the acquired measurements to reduce the effect of statistical variability on the results, see section 4.5.7.1. Another prob-
Elemental and Content Analysis
547
lem that can degrade the quality of spectral data is detector drifting, due to temperature changes. This is overcome by employing stabilizing electronics, see also section 4.5.7.1. A number of other parameters affect the response of a device monitoring natural activity, whether it is measuring the total count rate or acquiring a spectrum of emitted radiation. The inspection volume, or sphere of influence of a detector depends on the nature of the material surrounding the detector. Therefore, any surrounding fluid, tubing, casing, cement, etc., can affect the value of the count rate recorded by a detector inserted in a borehole. Eccentricity of a detector within the hole can also bias the results, by deviating them from the idealized calibration conditions. Moreover, if the sphere of influence is not completely filled with the formation material, a misleading indication will be obtained. The logging speed, along with the time-constant setting of the detector’s circuitry also affects the readings of the instrument. The faster the logging speed, or the longer the time-constant, the less representative is the recorded log of spatial changes in the bed formation. Reference [40] reported a number of applications of natural overall radioactivity measurement in well-logging. Lithology evaluation for potassium, uranium and thorium-bearing minerals and rocks; was performed using their emissions. The fraction of shales (the most common radioactive rocks) in reservoir rocks; was also estimated. A comparison between wells for shale content is possible by contrasting their natural emissions against each others. Sedimentology indications can be also deduced from the change of gamma emission with depth; the latter information is also used for depth control of drilling and testing equipment. Natural emissions from coal, due to the presence of uranium, thorium and potassium, are indicative of its presence and concentration. The natural gamma-ray activity per unit volume (specific activity) is related to coal concentration, or conversely to the absence of coal (or presence of ash). Natural activity emissions were, therefore, used for measuring the ash content of coal [639], and to discriminate low-ash coal from useless overburden and in-stream sediment [640]. The intensity of natural gamma emission, combined with a density measurement, using the backscattering of photons (see section 7.5) recorded with the same detector, provided an emission-density map from which coal, clay and sand strata were detected from logged drilled holes in a coal mine [641, 642]. The scattering of gamma-rays, introduced by a source, was also used, along with the detection of naturally emitted gamma-rays, to identify three basic components of brown coal formations (coal, clay and sand) [641].
548
Radiation Probing, Gauging, Imaging and Analysis
The 583 keV and 609 keV characteristic gamma-ray associated, respectively, with the decay of (a daughter of and (a daughter of were used to assay the thorium and uranium contents of soil [643]. The same approach was employed for measuring the distribution of natural gamma-emitting radionuclides in soil and water [644], by monitoring, in addition to the above emissions, the 911 keV gamma(a daughter of thorium) and the 1.46 MeV gamma-rays rays of of Airborne surveys are used in mineral exploration, including, in addition to uranium, Ag, Au, Be, Bi, Co, Cu, Hg, Mo, Ni, Pb, Re, Sn, W, Zn and Zr [323]. The 2.6 MeV gamma-rays emitted from the decay of years, half-life) was used for measuring the thorium abundance on the lunar surface [645]. Natural gamma-emission was also used to detect on-stream truckload quantities of shale in sedimentary iron-ore belts [384]. Natural radioactivity from thorium, uranium and their daughters, and from are found in high-grade hematite. The total gamma-activity in the 300400 keV range can be scaled to the alumina concentration of ferruginous scales, hence to the shale content or iron. However, other shale material, such as highly siliceous chert and jaspilite, have low natural radioactivity and, therefore, are not detectable by this method. The use of a large was necessary to enable detecNaI(Tl) detector tion of the small natural radioactivity of the shale. Also, gamma-rays spectroscopic analysis of river sediments collected around phosphate fertilizer plants indicated accumulation of natural radioactivity originating from effluent released from the plants [646]. Another application for natural radioactivity is to use the gamma emissions of from plant contraband materials (such as marijuana and tobacco) to passively detect their presence in cargo containers [647, 648]. Measurement of environmental contamination due to the Chernobyl Nuclear Power Plant accident was done by monitoring the characteristic gamma-rays emitted from the contaminating isotopes, etc. This method is also used for the characterization of nuclear waste, see for example [649]. In addition, contamination with plutonium and americium isotopes was detected by the characteristic x-rays from Pu (17.06 keV) and the 59.6 keV gamma-rays of using a planer HPGe detector [650]. A method for detecting and in contaminated soil, in a nuclear waste site, was reported in reference [651]. The method relies on measuring beta-particles emitted from or (decay daughters of and respectively), at a maximum energy of 2.3 MeV for each isotope. Using flat ribbons composed of numerous square scintillating fibers, and stacked on top of each other, with each connected to a photomultiplier tube, high energy
Elemental and Content Analysis
549
beta-particles will cause scintillation in a number of subsequent layers. On the other hand, lower energy beta-particles, arising from natural daughters, and its daughters and will sources (other only penetrate a layer or two, thus can be discriminated against. Neutrons emitted from plutonium can be used also for monitoring its presence in containers, either by direct counting of the total neutron emission or by coincidence measurement of neutrons emitted by spontaneous fission; the latter is particularly useful when non-plutonium related random neutron emitters are present [600, 601]. References [652] suggested the use of scintillating glass fiber detectors for the detection of plutonium, that may be concealed in freight and vehicles, by its neutron emission. In order to correct for neutron attenuation within the matrix material in which the fissile material is embedded, the transmission and scattering of was measured in some applications [653, 654]. Cosmic-ray interactions with matter produce a “neutron signature” that can be used for verifying the type of nuclear materials within a closed container [655]. When galactic high-energy cosmic radiation interacts with the elements of a planet, they release fast-neutrons. These neutrons are, however, slowed-down in energy by interacting with the nuclei of the regolith, and eventually reach the thermal energy. The neutrons can, therefore, activate the elements of the planet. The gamma-rays emitted from the activated elements can be used to characterize elements such as silicon, oxygen, iron, magnesium, potassium, aluminum, calcium, sulfur, carbon and hydrogen. In addition, water or ice, if present, would affect the is buried beneath a thick (a spectrum of the neutrons, even when refew hundred mm) hydrogen-poor soil [656]. The hydrogen in duces the number of fast and epithermal neutrons, by moderating them, and in turn, tends to increase the thermal-neutron flux [657]. On the other hand, an increase in both the epithermal and thermal-neutron counts was seen as indicative of the presence of a ice cap (frost that precipitates out of the atmosphere) above a hydrogen-rich soil, since the low absorption cross-section of allows more of the epithermal neutrons produced in the soil beneath to reach the atmosphere. This process was used in the analysis of both the Lunar and the Martian surfaces [658, 659, 660].
12.1.3.
Resonance Effects
Energy Spectrum. Resonances exhibited in the neutron total crosssection of some elements, see section 6.5.4, were exploited for elemental analysis by measuring the energy spectrum of transmitted neutrons. With neutrons in the few eV range, the technique was used to measure
550
Radiation Probing, Gauging, Imaging and Analysis
the isotopic abundance of nuclear reactor fuel elements [172], by measuring the energy of transmitted neutrons using a proportional counter detector. By analyzing the measurements at energies corresponding to the resonances of and the abundance of each isotope can be determined. Moreover, in a spent nuclear fuel, the abundance of and were also evaluated [172]. Resonances in the cross-sections of In, Hf, Au, Gd, Cd, Eu, Dy, Co, Ir, Mn, Rh, Sm, Ag and Ta were also used for measuring the concentration of these elements [343]. Neutron resonances at higher energies, between 1 and 3 MeV, observed in the cross-sections of H, C, N and O, was used to determine the concentration of these elements, using a pulsed beam of fastneutrons [173, 661]. A pulsed source enables the measurement of the energy of transmitted photons using the time-of-flight method, discussed in section 4.25. With a broad-energy beam of neutrons (from 0.5 to 10 MeV, obtained by bombarding a beryllium target with 4.5 MeV deuterons), the resonances in many elements can be measured simultaneously. This technique was, therefore, considered for the detection of explosives and drugs [662, 663, 664, 665]. The prompt gamma-rays that is usually associated with neutron production was also utilized to provide gamma-transmission measurements [666]. With gamma-rays in the energy range where Compton scattering dominates, the electron density, of the material present along the radiation source can be determined, see Eq. (3.40). While neutron transmission provides the atomic-density, N, then is a direct measure of the number of electrons per atom, i.e. the atomic number Z. This combined approach of neutron resonance transmission and gamma transmission improves the elemental discrimination ability of the detection system. The fast-neutron transmission spectroscopy techniques was also source [177], taking advantage of the wellapplied using a characterized and smoothly varying nature of the energy spectrum of this source. The analysis of the spectrum of fast scattered neutrons was also proposed for the detection of landmines [218, 667, 668, 669] and illicit drugs [669]. An empirical fast-neutron scatter/transmission technique was also proposed for bulk detection of explosives [670]; with neutron transmission providing an indication of the attenuating ability of the interrogated material, and the scattered neutrons indicate the mass-number, density and fast-neutrons cross-sections of the materials. The unique resonances in the scattering cross-sections of nitrogen and oxygen (two of the main constituents of nitrogen-based explosives) between 1 and 3 MeV energy provide a strong scattering indication,
Elemental and Content Analysis
551
which when mapped against the neutron transmission signal provide a distinguished indication of ammonium-nitrate (an explosive-like material) [670]. Transmission resonance was also utilized for measuring the amount of protein in meat [343]. The concentration of nitrogen is taken as an indication of the protein content. Therefore, by measuring the transmission of monoenergetic neutrons at the 432 keV resonance of nitrogen, its concentration, hence the protein content, can be estimated. Neutron-resonance transmission was also used to measure the isotopic content of fresh and spent nuclear reactor fuel samples, where the content of and in fresh fuel, and the abundances of 11 actinides and 5 fission products in spent fuel, were obtained with neutrons emitted from a 100-MeV electron Linac pulsed neutron source [671]. A similar approach was used to determine the absolute content of and in irradiated fuel, using a fast-chopper time-of-flight spectrometer [672].
Slowing-Down Time Spectrometry. Resonance effects can also be observed using slowing-down-time spectrometry. When a monoenergetic pulse of neutrons is slowed-down in a medium other than hydrogen, it tends to scatter into a narrow energy group, the value of which depends on the mass-number of the slowing-down medium. With such medium, a number of collisions are required to significantly affect the energy of incident neutrons, as evident from Eq. (3.80). However, a significant change in direction takes place and after a sufficiently large number of collisions neutrons “forget” their initial direction and energy, but tend to be “focussed” into a narrow energy band. To understand this focusing effect, let us assume that the total macroscopic scattering cross-section of the medium changes with neutron velocity, as where K and are constants. The average number of collisions per second would be equal to keeping in mind that is equal to mean-freepath of neutrons, see section 3.11. Higher-velocity neutrons will scatter more often, and consequently slow-down at a faster rate than slower Then, the neutron velocity, and in turn energy, will neutrons, if increase with time, after the issuing of the pulse. The energy of the slowed-down neutrons will then be approximately inversely proportional to the square of the slowing-down time [673]. Lead is a suitable element for use in this process, since its scattering cross-section is such that it satisfies the above required behavior of the scattering-cross section, with velocity, hence energy, at most of its energy range. The reader can verify this by plotting the cross-section using the on-line program of reference [27]. Other advantages of lead is that it is readily available,
552
Radiation Probing, Gauging, Imaging and Analysis
not highly absorbing of neutrons, and because of its high mass-number leads to a continuous slowing-down process. This technique, known as lead slowing-down-time spectrometry (LSuses pulses of 14 MeV neutrons, produced by the reaction, since neutron generators based on this reaction are readily available, see section 2.3.1.3. A neutron generator is placed at the center of a large block (a meter or two) of pure lead, with the interrogated object and detectors placed inside the assembly. The scattering of neutrons within the assembly allows the object to be subjected to neutrons at a wide range of energy. The technique has been mainly utilized for the assay of fissile materials, namely and These nuclides, unlike fertile ones such as have strong resonances in the eV range in their fission cross-sections. Therefore, the spectrum of the slowing-down time of neutrons depends on the amount of fissile material present in the interrogated object [674, 675]. DTS),
Gamma-Resonance. Resonance absorption with gamma-rays can also be used for elemental identification, provided that the gamma-rays are sufficiently high in energy to interact with the nucleus. For example, the 9.172 MeV nuclear level of can cause resonant absorption of 9.712 MeV photons, making it possible to determine the concentration of nitrogen, and hence detect explosive materials [676]. Such photons target with 1.75 MeV protons, can be produced by bombarding a to produce an excited nucleus, which then emits the excitation energy in the form of 9.172 MeV photons. The emitted photons can then be directed to the interrogated subject, where they are resonantly absorbed by the nitrogen of the object. From the reduction in the intensity of transmitted radiation, the concentration of nitrogen in the object can be determined. A similar technique can be used for the detection of chlorine-rich narcotics, with the 8.12 MeV gamma-radiation that is resonantly absorbed by175] [175]. Photon-Scatter Resonance. Borehole analysis for copper and nickel using gamma-ray resonance scattering was also reported [677], where gaseous and gamma-sources were used to produce photons with energies that coincide with the critical (resonant) absorption energies of the concerned nuclei, copper and nickel, respectively. For boreholes in rock of constant type and density, the number of resonantly scattered gamma is proportional to the concentration of the wanted element. More information on the use of gamma scattering in the assay of mine boreholes can be found in reference [678].
Elemental and Content Analysis
553
Charged-Particle Resonance. Resonance of charged-particle reactions are also exploited for elemental analysis. The backscattering resonance of alpha-particles at 3.045 MeV with was proposed for the analysis of oxygen in high atomic-number compounds, such as metal oxides and cubic zirconia [679] A number of reactions have strong resonances for activation by charged-particles, as listed in Table 8.8. The increased activation yield of these resonances has been used for the detection of carbon contamination under gold-covering of silicon substrates and for depth profiling of hydrogen in glasses, carbon, metal foils and geological samples. Sodium in glass and silicon substrates, aluminum in silicon and its compounds; and helium, nitrogen and fluorine in metals, were also measured with the technique [257]. This activation technique is particularly useful for analysis of fluorine in small quantities, a task that is not achievable by other methods [680]. Also, the resonant reaction was used to determine the lithium concentration in ‘smart glass’ (a glass that changes from clear to dark by applying electrical bias, typically consisting of two electrochromic layers of and [630]. Enhanced resonances activation of charged-particles was also used for the analysis of oxygen in silicon single crystals, in gallium phosphide oxide films on aluminum, and in metal single crystals and oxide flake (scale) [257]. Oxygen was also measured in silicon surface technology. The technique was also utilized to measure boron in silicon wafers, and aluminum in semiconductors. Resonant profiling was also used, with the reaction for examining the kinetics of hydrogen implantation-induced blistering of semiconductors; for measuring the hydrogen content in amorphous solar-cell materials; and for studying the reaction between water and soda-lime glass [630]. The reaction was also used to measure the profile of nitrogen implantation into aluminum, while the resonant reaction was utilized to determine the fluorine content in dielectric films [630]. Backscattering using 7.6 MeV ions was also used to perform depth profiling of oxygen and carbon in heavy matrices of gold, silver and copper [681]. In this process, advantage was taken of the resonances of the elastic scattering cross-sections at 7.3 MeV for O and 7.65 MeV for C.
12.1.4.
Fast-Neutron Scatteroscopy
The energy of a neutron after encountering an elastic scattering with a nucleus of mass-number A, is determined by value of A, as well as by the angle of scattering, see Eq. (3.80). Therefore, by fixing the energy and direction of an incident neutron beam, and monitoring the
554
Radiation Probing, Gauging, Imaging and Analysis
neutrons scattered at a certain angle, one can determine the value of A from the energy of scattered neutrons, and the density of the element of mass-number A from the intensity of the neutrons at that energy. This technique of measuring the energy of scattering to determine elemental information is called here scatteroscopy, and was proposed for measuring and in mixtures containing these the concentration of elements [228]. The technique was also investigated for detecting explosives by resolving the difference in energy loss of neutrons scattered by the four main elements of explosives: hydrogen, carbon, nitrogen and oxygen [682, 683]. The method was also used to detect these elements, in addition to Al, S, Fe and Pb, in samples weighing 0.2 to 0.8 kg [684]. The energy structure of the elastic scattering cross section of C, N and O, weighted by the energy spectrum of a Pu/Be source, was shown to result in characteristic peaks that were also reflected in the spectrum of backscattered neutrons [685, 686]. The relative ratio of these peaks can also be used for identifying materials containing high concentrations of these elements. Reference [687] studied the transmission characteristics of passing through rare earth and boron loaded concrete slabs, enabling the analysis of concrete for such elemental content.
12.1.5.
Charged-Particle Scatteroscopy
The dependence of Rutherford scattering (nuclear elastic) scattering of alpha-particles, or accelerated ions, on the atomic-number (see section 3.3.1.1), has been utilized for composition determination of thin materials. A number of detectors are available for measuring the spectrum of alpha-particles, including proportional counters, scintillation detectors, Frisch-grid ionization chambers and silicon gold surface-barrier detectors [688]. Reference [237] reported a number of applications. The method was used to determine the atomic-number of thick metal backings, and to obtain complete and detailed in situ chemical analysis of surfaces and thin atmospheres of extraterrestrial bodies. The method was utilized to study the structure and composition of mechanically polished and chemically etched surfaces of CdTe single crystals, and for near-surface analysis of oxygen-containing high atomic-number compounds. The concentration of thin films on high atomic-number substrates and high atomic-number bulk oxides was also measured with this method. The concentration of trace and minor elements (Na, S, Cl, K and Ca [689]) in cigarette tobacco was also determined using this technique. The method was also employed for elemental trace analysis of sugar-spirit solution, wheat and well-water samples. Other applications are also presented in reference [242]. Various types of ion beams were used to study the diffusion of a small cobalt surface impurity into
Elemental and Content Analysis
555
silicon and to characterize nitride and oxide layers on silicon. Changes in the tribo-surfaces of bearing steel subjected to lubricated sliding wear were also monitored with the technique, to examine the effect of additives to the lubricating oil in reducing wear and preventing seizure [690]. The elemental composition of various types of films and film deposits and coatings was also determined using this method. Reference [691] described a system useful for application of Rutherford scattering in an industrial environment, and summarized its utilization in the analysis of microelectronic materials and polymer and synthetic fibers and the study of catalysis agents such as cage compounds in zeolites. Reference [692] described the use of backscattering and forward scattering of ion beams for depth profiling of solids, and provided some representative applications. Alpha spectrometry has also been used to measure the concentration of various plutonium isotopes in samples, and in the analysis of irradiated nuclear fuel and cladding materials for actinide elements and for the chemical separation of actinides [688]. Alpha-particle backscattering, using a alpha-source, was also used for analyzing the chemical composition of the Lunar surface [693]. According to the kinetic of elastic scattering of alphaparticles, Eq. (3.19), for backscattering (i.e. at a scattering angle of the energy of a scattered alpha-particle, is related to its incident energy by:
where A is the mass-number of the target nucleus, and the value of 4 is equal to the mass of an alpha-particle in atomic-mass-units. Therefore, by measuring the scattering energy, one can determine the mass-number, hence identify, the present element. The intensity of scattered particles provides an estimate of the atomic concentration of the scattering element. Since alpha-particles are not very penetrating, the monitored scattering will emerge mainly from near the surface. But even then, an alpha-particle may scatter more than once before being reflected back to the medium, losing additional energy. However, the emerging scattered particles cannot have an energy greater than that of a particle that encountered only one scattering as determined by Eq. (12.3). Therefore, the energy distribution of the scattered alpha-particles from a thick target is a continuous distribution that extends from zero to a maximum energy, determined by Eq. (12.3), and is characteristic of the scattering element. Therefore, the energy at which the scattering spectrum sharply drops to zero corresponds to the values as determined by Eq. (12.3), from which the value of A can be calculated. A monoenergetic alphasource is needed for this application, in order to be able to make use
556
Radiation Probing, Gauging, Imaging and Analysis
of Eq. (12.3). Although, emits two main alpha energies [12], 6.069 (25%) and 6.112 MeV (74%), the two energies are so close that in practice they can be considered as a single energy. The half-life of the source is also sufficiently long (162.8 days) to be of practical value. This source was employed in the alpha-backscattering technique used by the Surveyor 5, 6, and 7 spacecraft [635]. The Mars Pathfinder mission used this technique in its Alpha-Proton-X-ray Spectrometer (APXS) for chemical elemental analysis of the Martian soil and rocks in situ near the landing site [632]. The APXS technique also employed an source and used the reaction for detecting Na, Mg, Al, Si and S, and the characteristic x-rays produced alpha-particle excitation for measuring heavier elements [633, 634]. The backscattering of beta-particles has also been used for composition indication. For example, the backscattering of beta-particles emitted form a source, and detected with a cadmium telluride solid-state detector, was used for the precise determination of the effective atomic-number of materials of atomic-number ranging from 9 to 30 [694]. Reference [24] reported a number of applications. The technique was also utilized to measure the lead content in glass, glazed and porcelain artifacts, and for determining the composition of bronze mirrors and vessels;. Japanese antiques were investigated with this method. The analysis of Pharmaceuticals for the content of heavy elements (Pb, Bi, Cu, Zn, Ca, Au, Sb, I, Hg, and Br) was also performed using this ions was utilized to study the stoichiomethod. The scattering of metric variation in semiconductor layers [695].
12.2. Atom-Based Analysis 12.2.1. Fluoroscopic Excitation Fluoroscopic emissions produced by photon or charged-particle excitation of atomic electrons plays a vital role in elemental analysis. The technique is discussed in section 8.7, and some of its applications are given here. Note that due to the limited penetrability of both the incident and emitted radiation, the method is useful for surface analysis and for examining small samples. The applications of the method can be classified into four categories: qualitative, relative, quantitative and trace analysis. Qualitative Analysis. The objective of this analysis is identify present elements without necessary determining their concentration. Qualitative analysis can also be viewed as a “probing” process for the quick assay of materials to determine whether certain elements are
Elemental and Content Analysis
557
present or not in a sample. This process can be useful, for instance, in detecting a certain contaminant in food produces or a pollutant in an environmental sample. Relative Analysis. This process aims at not only confirming that certain elements are present in an examined material, but also to determine their relative concentration, as done in the content analysis discussed in section 12.4. Signature analysis is used for this purpose, where the presence of main features (characteristic energy peaks) is ascertained as a finger print of the element(s) that ought to be present in a certain material. The intensity of these peaks in the detected signal can then be used to determine the relative content of the elements of interest. This process is useful in metal sorting steel by alloy type analysis of forensic samples and authentication of artifacts and currency [269], with the used isotope given in brackets. Quantitative Analysis. This is the process of calculating the concentration of all elements from their emission spectra. For this process to be accurate, factors that may influence measurements should be carefully considered. Such factors include: background radiation due to photon scattering by, or excitation of, surrounding material, counting dead-time effects (see section 4.5), and radiation-attenuation within a sample. Trace analysis. Detecting a small amount of an element requires particular attention, since the indication signal produced by such analysis can be so weak that it becomes indistinguishable from the background signal. It is, therefore, essential to obtain the maximum possible signalto-background ratio by judicious choice of the excitation energy, detector type, and when possible the inspected object itself. Trace analysis works best with small samples, where the effect of radiation scattering and attenuation is small. It may also be advisable to focus on detecting only one element, rather than measuring simultaneously multiple elements, so that the detection system can be optimized towards the characteristic energy of that element. Reference [696] provided the following recommendations for performing trace elements by fluoroscopic emission:
Monoenergetic sources are preferred over conventional x-ray tubes or bremsstrahlung sources, since the latter produces a continuum of scattering radiation that can interfere with the characteristic fluoroscopic x-rays. Therefore, characteristic x-ray tubes (x-ray tubes with a suitable primary target, or a supplementary secondary target, see section 8.7.2) or isotopic sources (e.g. or should be used.
558
Radiation Probing, Gauging, Imaging and Analysis
While the excitation energy needs to be slightly greater than the K or L absorption-edge energies of the elements to be analyzed, see section 8.7, it should not be too high to avoid introducing significant overlapping background by Compton scattering. The emitted radiation should be detected at angle near 90°, with respect to the incident radiation, since at this angle the probability of Compton scattering is minimal; in accordance to the Klein Nishina relationship of Eq. (3.41). To minimize absorption loses within an inspected specimen, its thickness should not exceed the thickness beyond which an increase in thickness does not appreciably increase the intensity of the emitted fluoroscopic radiation; hence the highest sensitivity is obtained with relatively thin specimens. The detection system should be designed to provide maximum detection efficiency and minimum dead-time loses (see section 4.5). Classification by Atomic Number. The classification of x-ray fluoroscopic emission according to the above mentioned categories depends to a great extent on the intent of the user. What matters is that there is a radiation source available to cause excitation and that a suitable detector is used to measure the emitted x-rays. In this regard, reference [24] classified elemental detection with fluoroscopic emission according to the atomic-number, Z, as follows: Z
(up to K): excitation energy is low, < 4 keV, requiring the use of proportional-counter (gas) detectors to provide the needed energy resolution for low-energy peaks.
21
(Sc – Zn): excitation energy is from 4 to 9 keV, making it possible to employ proportional, scintillation or semiconductor detectors. Excitation is usually achieved with radioisotopic sources.
31
(Ga – Ba): with the excitation energy between 9 and 33 keV, a number of radioisotopic sources can be used in this regard (see Table 2.7), along with mainly scintillation detectors; although proportional counters and semiconductor detectors are also applicable.
58
(Lanthanides): the excitation energy for these rare-earth elements varies from 33 to 55 keV, but their characteristic energies, from the and levels, interfere with each other, which makes it difficult to resolve their fluorescence spectrum without the use of a
Elemental and Content Analysis
559
detector with a high-energy resolution such as the high purity germanium detector, see section 4.3. Photon excitation of these elements can be caused by a number of radioisotopes: while electron excitation can be introduced by
(a beta source with a maximum energy of 224 keV) [697].
(Hf and beyond): with a relatively high excitation energy (55 are to 99 keV), isotopic sources such as and needed. Only scintillation and semiconductor detectors are suitable for this relatively high photon-energy. Since it is vital in fluoroscopic emission to have the right source energy to excite the element(s) of interest, the radiation source used is identified in brackets when discussing the applications below. Note that stating a kV value indicates the use of an x-ray machine as a primary source, while the presence of a slash (/) after a source signifies that the primary source is accompanied by a target that emits the excitation radiation when the target is excited. Since there is an enormous number of applications, only some representative examples of x-ray fluoroscopic emission (XRF) are given below. Food and Agriculture Industry. Photon excitation was used for the analysis of orchard leaves (40 kV W/Mo) for Cr, Mn, Fe, Ni, Cu, Zn, As, Br, Pb, Sr and Pb [696, 269], dried vegetables (60 kV Ag/Nd), [269]. The method was also utilized for and freeze-dried fish the analysis of Mn, Fe, Co, Cu, Zn, As, Br, Rb, Sr and Zr in tobacco, using and sources [689]. Process Industries. XRF is used in the inspection of paint for toxic components (60 kV Ag/Nd). The method was also employed to determine the concentration of bromine in a liquid catalyst used in a petrochemical plant, by exciting the bromine’s 11.9 keV x-rays with an a 59.6 keV photons bombarding a silver target, producing 22.1 keV x-rays. Chlorine in rubber rhenium (a catalyst for hydrogenating of fine chemicals in oil, and arsenic in aqueous solutions were also analyzed [269] Other solutions analyzed by XRF include copper in electrolytic solutions and uranium in aqueous solutions [24]. Coatings were also analyzed for the determination of lead, titanium, mercury, copper and arsenic in paintings, such as those applied to stove finishing, latex paints and inks [24]. The concentration of uranium and plutonium in highly radioactive solutions is determined in nuclear fuel reprocessing plants The technique was also used for the determination of the presence of gaseous uranium
560
Radiation Probing, Gauging, Imaging and Analysis
inside cylinders [270]. X RF is also used for monitoring and subsequent control of gas emissions from industrial furnaces, and for detecting trace metals in process industries and in the feed water of nuclear power plants [698]. Coating and Substrate Interference. When a coating and a substrate contain a common element, the use of XRF to detect elements in the coating becomes problematic, due to interference from the substrate. This is encountered for example when Zn/Fe (galvanneal) coating is used on steel, where the Fe fluorescence emerges from both the coating and the steel substrate. Reference [699] overcame this interference by using two collimated x-ray beams as the excitation sources, one directed normal to the surface and the other at a large inclined angle. The inclined beam travels a longer distance within the substrate, so that when it reaches the substrate its intensity is reduced. Therefore, the inclined beam is used to detect the Fe fluorescence in the coating, while the normal beam is utilized for Zn fluorescence.
Metal Processing. XRF is used for analysis of lead in free-machining steel added to to improve the steel's machining properties and Mn, P, S and Si in blast furnace heats (molten liquid poured in an openhearth steel making process (Cr tube/Cl) and Cr, Mn, Ni, Nb and Mo in stainless steel (Rh tube) [269]. The method has also been utilized for the determination of the following elements in various types of steel with isotopic sources: Cr Mo and NB W and Pb [24]. The same reference also reported the use of XRF to determine Pb in leaded brass Cu in Cu/Sn Sn in Cu/Sn Ni in Ni/Cu/Zn and Al alloy Sn in bronzes and gunmetal and Sn in Sm/Pb solder Mineral Processing and Geological Samples. Chlorine and lead in mineral process materials are analyzed with XRF [269]. Glass, pottery and rock specimens were analyzed for K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, As, Se, Br, Rb, Sr and Pb (42 kV Mo secondary tube) [696]. Geological materials were investigated using the XRF technique for measuring the content of Au Ag V U etc. [24], Slurries can be analyzed on-line with XRF to determine the concentration of Pb calcium tin barium zinc copper etc. [24] In the construction industry, XRF is used
Elemental and Content Analysis
561
for determining the concentration of Mg, Al, Si, Ca and Fe in (Rh tube or [269, 24]. Environmental Samples. XRF was used for the analysis of particulate filters for Ar, Ca, Ti, Cr, Zn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr (42 kV Mo tube) [696]. Reference [643] reported the use of the method to measure the concentration of pollutant around tin mining and smelting operations: Al, Si, Ca, K, As, Ni, Fe and Ti (20 kV excitation potential) and Zn, Sn, W, Bi, Pb and Th (40 kV with a thick rhodium filter). A similar process was used for analyzing suspended dust particulates within and around cement plants [700]. Water is also analyzed for the determination of trace metals [24]. Heavy elements in plants are also detected with the XRF technique for Mn, Fe, Ni, Cu, Zn and Pb Br and Sr [24]. The concentration of chromium in air breathed by workers, during welding chromium-nickel steel, was also determined with XRF [270]. Others. Other interesting applications of XRF include the analysis of genuine and counterfeit bills by comparing their composition and for the forensic analysis of fired or of unfired pistol powder residue [24]. Modern fake reproduction of ancient porcelain, on an object tiles and clay work were also detected by analyzing their composition using XRF [270]. Reference [701] also suggested the use of 80 keV K level of lead to determine its concentration in Pb-Zn deposit ores, with the excitation caused by source photons scattered within the medium. XRF was also used in the characterization of a North Sea reservoir by analyzing stripped samples [702]. Excitation of uranium and plutonium K x-rays, by or 150 kV x-ray sources, and L x-rays by 30 or 55 kV x-ray sources were used for the analysis of both elements in samples of nuclear fuel at different cycle stages, e.g. ores, reprocessing solutions and mixed oxide fuel pellets [703]. The gold-colored layer on the scull piece of a medieval iron-based helmet as the excitation source [406]. Using an Xwere analyzed using ray tube (15 kV, Mo target and Zr filter), and and sources, the XRF technique was used to characterize archaeological ceramics, by measuring their Ca, Fe, Ti, Zr, Ni, Cu, Zn, Rb, Sr, Ba and Y content [704]. PIXE. Particle-induced x-ray emission (PIXE), discussed in section 8.7.3, plays an important role in aerosol analysis [705], particularly in the analysis of very small samples and thin targets, due to the limited range of charged-particles causing atomic excitation. Quantita-
562
Radiation Probing, Gauging, Imaging and Analysis
tive analysis with PIXE is limited to elements of a mass-number of 11 or higher (Na and beyond), due to the lower energy-loss (degradation) necessary for excitation, and the lower x-ray production cross-section of lower atomic-number elements [706]. Reference [267] reported that aerosol analysis represents about 20% of all PIXE applications, and included analysis of samples drawn from urban atmosphere, underground mines, stratospheric and air particles. In addition, PIXE is used for the analysis of water samples for trace amounts of elements [271]. PIXE is also utilized for the analysis of geological samples, such as rocks, mineral drill cores, deep-sea ferro-manganese nodules, etc. [271], and analysis of art and archaeology [707]. Stainless steel foils and iron substrates were and microbeams, as well as a 2 MeV analyzed using a 5 proton beam [708]. X-ray excitation by alpha-particles is also utilized in the alpha-proton-x-ray spectrometer (APXS) to analyze in-situ the composition the surface of Mars in the Pathfinder mission [632, 633, 634] and in the Surveyor lunar missions [635], see section 12.1.5. The ionoluminescence method, see end of section 8.7.3, has been used, in combination with PIXE, for rare-earth element analysis [709], such as in characterizing zircon mineral grains [710]. The method has been also used for the analysis of diamond and other crystals [711], and for the study of ore metal segregation between magmatic brine and vapor [712].
12.2.2.
Composition Indication
Photon interactions, as indicated in section 3.4, are mainly interactions with the individuals electrons of the atom, or with the atom as a whole. Therefore, photon interactions tend to provide atomic, or more precisely atomic-number, indications, rather than element-specific indications. For a compound, photon interactions provide indications that depend on the effective atomic-number of the compound, as defined in appendix E. Such indications can be used for distinguishing between two materials that are different in their atomic-number, but may be close in their density, or for the detection of the presence of a class of materials in a certain range of atomic-numbers. Since the most dominant photon-interaction process, Compton scattering, depends on the electron-density of the material, see section 11.1, it alone does not give composition indications; except in the case of hydrogen-rich material, as discussed in section 12.3.4. However, composition indications can be provided by using a combination of Compton scattering and some other photon interaction. At low-energy, the photoelectric effect (photoabsorption) becomes dominant, and is strongly dependent on the material’s atomic number. Using Eqs. (3.30) and (3.40), one can express the ratio between the macroscopic cross-sections for the photoelectric effect
Elemental and Content Analysis
563
and Compton scattering as:
where Z is the effective atomic-number of the material, see appendix E, N is the atomic-density, the subscripts and c refer, respectively, to the photoelectric and Compton effects, E is the energy at which the interaction takes place and the value of as indicated following Eq. (3.30), varies from 3 to 5, depending on Z and Therefore, at a given energy, the ratio between the cross-section of the photoelectric effect and that of Compton scattering becomes dependent on the atomic-number. Note that the use of the ratio of the two reactions, rather than relying only on the strong dependence on Z of the photoelectric effect, is necessary to eliminate the dependence of the latter on the material’s electron’s density. The question now is how to devise simultaneously two independent indicators that reflect the occurrence of both the photoelectric effect and Compton scattering. A number of possibilities exist, as schematically shown in Figure 12.1, and discussed in the ensuing subsections.
12.2.2.1
Critical-Edge Absorption
If the photon source energy is around the critical absorption-edge of an element, the intensity of the transmitted or scattered radiation would considerably decrease, and the element can be detected within a sample. Elemental tomography using this approach was proposed [713], employing beams from synchrotron-radiation accelerators (see section 2.1.5.1), since such beams can be tuned to the energy of the element of interest. However, the photon energy that corresponds to the absorption-edge of elements is quite low, limiting this elemental tomographic approach to small samples.
12.2.2.2
Dual-Energy Transmission
One can perform two transmission measurements, one at high energy, and the other at a lower photon energy, over the same path length. In this approach the indication obtained is an integral indication over the entire path length; Figure 12.1.a. The measurement model for this method can be formulated with the aid of Eq. (6.1) as:
564
Radiation Probing, Gauging, Imaging and Analysis
where I refers to the intensity of the transmitted radiation through a material of thickness, is the intensity at zero thickness, is the macroscopic cross-section, and and c refer, respectively, to the photoelectric effect and Compton scattering. In the model of Eqs. (12.5a) to (12.5c), it is assumed that the Compton scattering cross-section at is negligible compared to that of the photoelectric effect, thus the total cross-section at is approximately equal to At energy, E, because of the dominance of the total cross-section is set equal to Compton scattering. Using Eq. (12.4), one can see that the logarithmic ratio of the transmission measurements (transmittance), Eq. (12.5c), provides an indication of the effective atomic-number of the material present along the traversed distance, If the transmitted radiation encounters more than one material along then the Z indication will be
Elemental and Content Analysis
565
a weighted average of the atomic-number of the encountered material in accordance to the portion each element occupies across the distance This dual-energy transmission method is the basis of the dual-energy x-ray imaging method used in detecting suspect materials in passenger luggage, see section 13.5. Reference [714] suggested the use of three monochromatic, filtered xray beams for the detection of the concentration of elements (Cl, O, N and C), by monitoring the photoelectric effect (absorption) of photons at energies of 60, 65 and 70 keV, and reconstructing a tomographic image at each of those energies. In a similar fashion, two different energies, within the energy spectrum of transmitted x-rays (less than 25 keV), were employed to determine the mass-fraction of elements within materials composed only of hydrogen, carbon and oxygen, such as combustion materials [715].
12.2.2.3
Transmission and Scattering
Another approach to composition-indication is to record a transmission measurement at low-energy, for the photoelectric effect, while monitoring photon scattering from the same incident beam. Since Compton scattering is possible at all energies, according to Eq. (3.40), this approach can be used to obtain a composition (Z -number) indication of the material encountered along the path of the transmitted radiation; though the scattered photons are attenuated by the surrounding materials as shown schematically in Figure 12.1.b. Modeling the transmission measurement, T, at using Eq. (12.5a) and the scattering measurement, S, with the aid of Eq. (7.12), one obtains:
is the macroscopic cross-section of the radiation before scatwhere tering (along a distance and is that after scattering (along a is the macroscopic cross-section for Compton scattering, distance K is a system constant that incorporates the source strength, detector efficiency and system geometry. Note that because of the dominance of the photoelectric effect at energy its cross-section is used in place of the total cross-section. The composition indication provided by and is dependent to some extent on the di-
this method, via mensions of the object, unlike in the dual-energy transmission method (section 12.2.2.2) where dependence on the object thickness, is elim-
566
Radiation Probing, Gauging, Imaging and Analysis
inated, see Eq.(12.5c). On the other hand, the transmission-scattering method provides indications that cover a more diverse portion of the object, than that is covered by the scattered and transmitted radiation, unlike the dual-energy transmission method which only spans one chord of the object, as indicated in Figure 12.1. The transmission-scattering method, like the dual-energy transmission method, is also employed in the radiograhic imaging of passenger luggage, see section 13.5.
12.2.2.4
Dual Scattering
A third approach is to utilize a high-energy source, and monitor photons scattered at high energy, i.e. after a single collision, and those that scattered after many collisions, Figure 12.1.c. The latter photons would be at low-energy so that they are attenuated by photoelectric absorption as they travel towards the detector. The ratio of the two scattering measurements would then be indicative of the effective atomic-number of the material covered by the scattered photons. This can be shown by formulating the scattering measurements, similar to Eq. (12.6b), as follows:
where and are system constants at the high and low scattering energies, respectively, is the electron-density, the bar designates some “lumped” cross-section value over the many interactions that radiation goes through until it reaches the lower energy, F and G refer to some function formulations, all other parameters are as defined following Eq. (12.6c), and use is made of the expressions in Eq. (12.4) to arrive at the arguments of the functions. Note that inherent in Eq. (12.7a) is the assumption that photons scatter only once before reaching the detector. However, even with a few collisions, one would still expect to be a function of since Compton scattering will remain dominant. The lumping of the cross-sections in Eq. (12.7c) is possible, since after a few collisions photons would tend to “forget” their point of origin and behave as an independent “cloud” of photons that is not directly related to the photon source and can be “lumped” into an equivalent point. The function can be separated, by proper choice of the detection energy, into two functions, so that This function separation is justified by the fact that the scattering of
Elemental and Content Analysis
567
low-energy photons is dependent on and the attenuation process is dominated by photoelectric absorption, which makes the two processes mutually exclusive (i.e. a photon is either scattered or absorbed but not both). In between the low and high energy, the two processes of photoelectric absorption and Compton scattering are competitive, with neither one dominating the other. In that region, it would not be possible to use a “lumped” parameter to arrive at a model like that of Eq. (12.7b), since the photon flux distribution would still be dependent on the source photons and their behavior during the first few collisions. The low and high energy windows need, therefore, to be carefully chosen so that is an atomic-number indicator that is independent of density. In addition, the low-energy scattering should be monitored at a distance sufficiently away from the source, to allow photons to lose enough energy so that the photoelectric effect becomes dominant. Thus, the dual-scattering method provides an indication over a wide volume of the inspected medium. However, as can be seen by comparing Eqs. (12.5a) to (12.5c) and (12.6a) to (12.6c) with Eq. (12.7a) to (12.7c), the dualscattering method is not a direct atomic-number indicator. The dual-scattering method is employed in a litho-density tool in oil exploration for examining rock and mineral formations; with providing the density signals, as discussed in section 11.1, while identifying various rock and minerals [40] and for in situ bulk density of surface formations and average atomic-number [716, 717]. The method has also been proposed for detecting explosives in luggage [718], and narcotics hidden in cargo containers [719]. The same modality was used for the determination of coal face ash content [720], employing a low-activity (1.8 MBq) source along with a small (0.35 MBq) source as a gain stabilizer, i.e. a marker with respect to which energy is calibrated. A similar approach was used for the determination of ash in coal seams intersected by boreholes [721, 722]. The application of the same approach to delineate iron deposits and determine their grade in borehole logging is reported in reference [723]. Reference [724] defined a spectral sensitivity matrix of multiscattered radiation which relates linear variations in the material properties to those of the spectra.
12.2.2.5
Dual-Energy Scattering
A fourth approach in composition indication is to monitor the Compton scattering of photons at two different source energies, one at a higher energy where the attenuation of the scattered photons is mainly via Compton scattering, while the second source energy is lower so that scattered photons are attenuated by photoelectric absorption, Figure 12.1.d. This method eliminates the needed to place two scattering detectors
568
Radiation Probing, Gauging, Imaging and Analysis
away from each other as in the dual-scattering method, and does not require access from two opposite sides of an object as in the case with methods employing transmission measurements. The dual-energy scattering process can be modeled using Eq. (7.12) as follows:
where H refers to the high-energy source, L to the low-energy one, and the other notations are analogous to those used in Eqs. (12.7a) to (12.7c). Note that the formulation of Eq. (12.8b) assumes single-scattering, or an equivalent “lumped” scattering process. This method, as Eq. (12.8c) shows, does not provide a density-independent indicator, but its dependence on the atomic-number, Z , is stronger (to the power than the other methods, which also reduces the dependence of on density. An example application of this method is in the use of backscattering of (1.17, 1.33 MeV) photons to determine the grade of iron ore in samples (iron content), by detecting photons scattered to 46-180 keV for low-energy scattering and 200-1000 keV for high-energy scattering. The ratio of these measurements were reported to provide a densityindependent iron-content indicator [384]. However, in manganese-rich ores, such technique can give a misleading indication, due to the proximity of the atomic-numbers of Mg (25) and iron (26). Elaborate analysis of the energy spectrum of backscattered photons, see section 7.5.6.1, from (662 keV) was also shown to provide rock properties, such as heavy-element content, density and grain size, and was also used to determine the diameter of a borehole [219].
12.2.2.6
Coherent Scattering
Aside from the photoelectric effect, advantage can be taken of the coherent (Rayleigh) scattering process, which also has a cross-section that is strongly dependent on the atomic-number, see Eq. (3.63). Since Rayleigh scattering is a coherent wave interaction that causes only a small change in the direction of the incident radiation, while not changing its energy (see section 3.4), a scattering detector needs to be placed in the proximity of the path of the incident radiation beam, see Figure 12.1. As explained in section 3.4.3.1, the photon energy does not change when Rayleigh scattering occurs, but is altered by Compton scattering, Eq. (3.37). Therefore, Rayleigh scattering can be distinguished
Elemental and Content Analysis
569
from Compton scattering by the photon energy. This, however, requires the use of a monoenergetic source, for ease of discrimination between the two effects. Also, at the small scattering-angles at which Rayleigh scattering dominates (see section 3.4.3.1), the energy change associated with Compton scattering, as can be deduced from Eq. (3.37), would be also small. Therefore, a detector with good energy resolution is required to distinguish between the two modes of scattering, as they need to be measured at the same angle so that the same point of scattering (as defined by the intersection of the incident and scattered beams) is monitored. In Rayleigh scattering, the source energy has to be reasonably low, as Eq. (3.4.3.1) indicates. One of the isotopic sources listed in Table 2.7, such as can be used for this purpose. Although these sources provide monoenergetic photons, which makes it easy to identify Rayleigh scattering by its lack of energy change, the radiation intensity of such sources tends to be quite low, unless a large amount of radioactivity is employed. Therefore, effort was made to make use of monoenergetic photons from x-ray machines. In one application, a secondary tantalum target was used within a 150 keV x-ray machine to produce the Ta (57.5, 57.3 keV) and (66.9 keV) lines [725, 726], which are at about isotopic source (59.5 keV). The the same energy produced by an same workers, using a scattering angle of 12°, also applied the so-called “source/detector filter” technique to avoid the use of a high-resolution expensive photon detector to distinguish between Rayleigh and Compton scattering. An erbium filter was used, as it has an absorption K edge at 57.48 keV, which increases its photon absorption from to Therefore, with this filter placed in the path the incident beam, it attenuates the 57.5 keV peak of the source significantly, reducing both the amount of Rayleigh and Compton scattering, resulting in a total scattering count rate, that can be expressed as:
where the subscript s emphasizes the fact that the incident source beam was attenuated by the erbium filter, T(E) is the attenuation factor introduced by this filter at the source energy E ( = 57.5 keV), and R and C refer, respectively, to the amount of ‘unfiltered’ Rayleigh and Compton scattering signals. Now, by removing the filter from the path of the incident beam and placing it in the in the path of the scattered beam, i.e. detected beam, the detector will record a count rate, that can be expressed as:
570
Radiation Probing, Gauging, Imaging and Analysis
where is the energy of the scattered photons as determined by the Compton scattering kinematics, Eq. (3.37), at the angle of scattering. Note that the energy of photons after Rayleigh scattering stays at the same energy as that of the source. Using Eqs. (12.9) and (12.10), one can show that the Rayleigh-to-Compton scatter ratio (see section 7.3.10) can be expressed as:
Note that due to the nature of the source and filter involved. The scatter ratio of Eq. (12.11) is a strong function of the atomic-number of the scattering medium, as indicated earlier, and was confirmed by measurements [725]. In principle, the effective atomicnumber of materials of atomic-number from six to 83 can be determined by the Raleigh-to-Compton ratio. Applications of the Rayleigh-Compton scatter ratio include: measuring the surface composition of heavy elements, in particular titaniumrich alloys containing aluminum and zirconium [727], and the analysis of bronze or silver-copper alloys [728]. The same method was applied to the determination of the effective atomic-number of compounds of effective atomic-numbers less than 20 [729]. This ratio technique was also utilized for measuring the concentration proportions in substances of major compounds of low atomic-number; such as fat and water content in milk or in meat, and reaction products in organic chemistry [730]. The method was also used in the investigation of carbonization (conversion to carbon) of olive stones by heating them up to high temperature [731]. The ash content in coal samples was also determined by the Compton-Rayleigh scatter ratio [732].
12.2.2.7
Pair Production
In applications where it is not possible to inject a positron emitter within the object to be interrogated, as in the case with solid objects, positron emission may be introduced via the pair-production interaction of photons, which produces a pair of electrons and positrons. At photon energy above 1.022 MeV, the pair-production interaction comes into play, as discussed in sections 3.4.4 and 8.4. Positron annihilation occurs almost immediately and within a very short distance from its point of origin, and produces two 511 keV photons that can be used in emission imaging (discussed in section 8.8.3). The unique energy of these photons makes it possible to distinguish them from scattered photons, or those produced by bremsstrahlung radiation resulting from the recoil electrons of Compton scattering. The photoneutron interaction, discussed
Elemental and Content Analysis
571
in section 8.3, may also lead to the production of positron emitters, particularly by the activation of light elements. Since the cross-section for pair production, Eq. (3.73), is proportional to where Z is the atomic number, positrons induced by this reaction will be strongly indicative of the atomic-number (hence composition) of the positron-emitting material. This ability to distinguish between elements of different atomicnumbers makes this method particularly suited for locating high atomicnumber (heavy) objects in less dense matrices [733]. Reference [734] proposed the use of this method for inspecting the position and condition of rebars inside steel reinforced concrete. Pair-production was also used to measure the ash content (high atomic-number minerals) in coal, along with Compton scattering, since the intensity of annihilation gamma-rays depends on both the atomic-number and density of the material while that of the scattered photons depends only on its density [735]. Isotopic sources that are suitable for inducing pair production are: (1.27 MeV), (1.17, 1.33 MeV), (1.76 MeV) and (69.98 y half-life, 2.615 MeV from decay of daughter Linear accelerators can also be used in this regard, offering the advantage of a high intensity source, but with continuous energy distributions. Reference [736] investigated the use of a 6 MeV accelerator, showing the change in positron emission intensity with atomic-number, Z, from Z = 14 (silicon in sand) to Z = 82 (Pb), while reference [733] studied positron emissions from Z = 4 (Be) to Z = 82 using a source. In the latter work, the 511 keV photons of positron-annihilation were segregated from the rest of the photon spectrum using a high resolution gamma detector (HPGe), while reference [736] reported the use of a difference-filter method, see section 15.2.1.2, to avoid the employment of an expensive energy resolving detector.
12.3.
Hydrogen Measurement
This entire section is devoted to hydrogen, because of its natural and industrial importance. Hydrogen is the most abundant isotope in nature. It is the “maker of water”, as its name means in Greek. Detection of hydrogen is, therefore, associated with the detection of moisture, wetness, dampness and steam. Hydrogen is also an essential component of the many hydrocarbon compounds encountered in biological structures, petroleum and its produces, polymers, etc. Moreover, hydrogen interacts with metals forming hydrides that can cause embrittlement and subsequent deterioration of metallic structures.
572
Radiation Probing, Gauging, Imaging and Analysis
Hydrogen Index. The hydrogen concentration is often indicated, for convenience, by the hydrogen index ( HI ):
The atomic-density of hydrogen in water at standard temperature and pressure (room temperature and atmospheric pressure, STP ) is hydrogen atoms per of water. For hydrocarbons, the HI value can be very small (for gases) to close to unity for some of the heavier oils, depending on composition, phase (gas or liquid) and temperature and pressure. It interesting to remark though that while the HI value for pure water at STP is unity, under the same pressure and temperature, the HI value for saline water is only 0.92 [40]. This reduction in the hydrogen content is due to the fact that the dissolved salt (NaCl) displaces hydrogen, thus reducing its atomic-density. Methods of Detection. Hydrogen has three main basic properties that makes its amenable to detection by radiation: 1 It has about the same mass as a neutron, making it the most effective neutron-slowing down nuclide (see section 3.5). 2 When it captures a thermal-neutron, it emits a characteristic highenergy (2.2232 MeV) gamma-ray (discussed in section 12.1.1). is the only isotope 3 It is the only neutron-free nuclei, therefore ratio of unity, where Z is the atomic-number and A is the with mass-number. Neutron Slowing-Down. The hydrogen nucleus is easily detectable by neutrons. Due to its superb slowing-down power, the amount of fast-neutrons slowed-down (by scattering) in a medium is a direct indication of its hydrogen content in that medium. As indicated in chapter 4.4, the detection of neutrons is most efficient at the thermal energy. Therefore, the slowing-down of neutrons is often detected at the thermal energy using one of the common thermal-neutron detectors and crystals). Note that neutrons need not reach the thermalenergy to provide indications on the presence of hydrogen. Measuring neutrons as they are slowed-down to the epithermal energy (say between 0.1 eV and 1 keV) is also indicative of the hydrogen content. This is particularly useful when measuring a small amount of hydrogen that is not sufficient to fully slow the source-neutrons down to the thermal-energy.
Elemental and Content Analysis
573
Thermal-Neutron Capture. Hydrogen has also a good neutron capture cross-section for neutrons (about 330 mb [176]). This neutron -capture process is accompanied by a characteristic gamma-emission at an energy of 2.2232 MeV (see Table 8.3), which is used to uniquely determine the hydrogen concentration. Since thermal-neutron sources are not readily available, a fast-neutron source can be used if the amount of hydrogen in the inspected medium is sufficient to slow-down the neutrons to the thermal-energy where they can be readily captured. In such arrangement, one can view the capture of slowed-down neutrons and the subsequent gamma emission as a means of indirectly detecting thermalneutrons. The advantage of detecting generated gamma-rays, instead of measuring the thermal-neutron flux, is that gamma-rays are more penetrating than photos, thus a gamma-ray detector would cover a larger volume than a thermal-neutron detector, providing a larger domain of influence. However, this is not an efficient detection process due to the usually small neutron-capture cross-section of the inspected material, in comparison to that of a neutron detector, and to the divergence of the emitted gamma-rays over a wide area away from the gamma detector. Change in Indication. The microscopic cross-section for inelastic scattering of beta-particles with the atomic electrons is a function of the atomic-number, at a given source energy, as Eq. (3.26) indicates, and the macroscopic cross-section is, in turn, a function of Also, the macroscopic cross-section for Compton-scattering is proportional to see Eq. (3.51). The value of is equal to about 0.5 for all atoms, with the exception of where it is equal to unity. Therefore, the presence of hydrogen enhances the probability of both inelastic beta-particle scattering and Compton photon scattering, for the same material density. This is useful in detecting hydrogen when it is present at a quantity that is small enough not to affect the material’s density, but is sufficiently large to show an overall enhancement of the scattering of beta-particle or photons. Hydrogen-Related Properties. The detection of hydrogen is usually used as indicator of water and other hydrogen-containing compounds, but other material properties can also be related to the hydrogen content. For example the lack of hydrogen can be used as a measure of the void (vapor) volume-fraction of boiling water, since the hydrogen concentration in the vapor phase is negligible in comparison to that in the liquid phase up to about 10 MPa in water. Similarly, since rock grains (such as quartz, calcite, etc.) contain no hydrogen, the presence of hydrogen in a ground formation is indicative of the voided
574
Radiation Probing, Gauging, Imaging and Analysis
(pores) volume, through which water and other hydrogenous materials can exist. The fraction of that void is known as porosity. Hydrogen content can also be related to the asphalt-cement content of paved roads. Asphalt mixes consist mainly of the asphalt cement, aggregates, and air voids. While the amount of air void can be determined by an overall density measurement, see chapter 11, the asphalt content can be estimated from a hydrogen measurement. Asphalt is a bituminous derivative of petroleum containing a wide variety of hydrocarbons, while aggregates consist mainly of aluminates and silicates of calcium. Therefore, hydrogen is predominantly present in the asphalt cement, though it is also present in the water of the mix and within the minerals in the aggregate. However, it is generally assumed that the amount of asphalt is directly proportional to the hydrogen content in the mix, and a hydrogen measurement is, therefore, indicative of the asphalt cement content.
12.3.1.
Neutron Slowing-Down
Scatterometery (section 7.5), neutron transmission (section 6.1), the lifetime of a fast-neutron (section 9.4), or neutron activation (section 12.1.1) can be used as indicators of the slowing-down of neutrons by collision with the hydrogen nuclei. Neutron-slowing down is accomplished after neutrons encounter a few collisions with the hydrogen in the medium, see section 3.5. However, some extraneous factors affect this process and may give misleading indications. Although neutrons lose most energy per collision when interacting with hydrogen, they also lose energy, though to a lesser extent, by colliding with other elements present in the medium, see section 3.5. Also, slow-neutrons are absorbed by elements other than hydrogen. Lithium, boron and chlorine are some of the strong neutrons absorbers that may be present in a practical situation. These absorbers remove neutrons that would have otherwise interacted with hydrogen, and thus can influence the hydrogen measurement. Also some elements may have strong resonances in their absorption cross-section at higher energies, typically in the keV range. These resonant absorbers will reduce the number of neutrons available for slowing-down by hydrogen, and in turn lead to an underestimation of the hydrogen content. Therefore, the composition and density of a dry medium can affect the neutron flux distribution, and in turn the response of a device in the presence of hydrogen. Theses effects can be accounted for to a large extent by calibrating the device in a medium similar in its elemental content to the investigation medium.
Elemental and Content Analysis
575
Measurement Models. The measurement model for the response of a hydrogen measurement device that relies on neutrons slowing-down can in general be expressed as:
where N is the device’s response (say, count rate) measured at a hydrogen density of is the count rate at zero hydrogen content (i.e. due to the contribution of radiation background and the matrix material in which hydrogen is embedded), K is a constant that represents the total cross-section of the medium for the slowed-down neutrons and the distance they travel in the medium before reaching the detector (as this depends on the source-detector arrangement), and C is a system constant that incorporates factors such as the source strength, detection efficiency, etc. The model of Eq. (12.12) is based on the notion that the number of slowed-down neutrons increases linearly with hydrogen content, but also decreases exponentially with hydrogen content as hydrogen self-absorbs the slowed-down neutrons. As schematically shown in Figure 12.2, the hydrogen content can be measured in a small confined volume, or within an extended large medium. For these two limits, the model of Eq. (12.12) can be applied as shown below. Confined Medium. Water in a pipe and a soil sample placed in a small test tube are examples of confined media, where the neutron attenuation can be ignored, and Eq. (12.12) reduces to the linear equation:
This is the model used for two-phase flow measurements [213]. Extended Medium. Ground soil, borehole, and a large water tank are examples of extended media, where all neutrons are slowed-down regardless of the hydrogen concentration, as they can travel an unlimited distance. Then the linear dependence in Eq. (12.12) can be replaced by a constant, leading to the model:
where the constant C is replaced by another constant that also depends on the investigated medium. This is the model used in neutron well-logging tools for hydrogen-index measurement [40], where the neutron source is located within the ground with the aid of an access tube. Obviously, only neutrons reaching a detector will be measured, thus the response of a device is confined to a “domain of influence” around the
576
Radiation Probing, Gauging, Imaging and Analysis
detector. If the source and/or the detector are placed at the surface of the ground, or the surface of some other extended medium, such as a concrete structure or an aggregate material, the response of the device will be complicated by the escape of neutrons away from the object. This skews the detector’s domain of influence, by virtue of having a large portion of the source’s field-of-view outside the inspected medium. An approximate, but more encompassing, model of the device’s response can be derived from two-group diffusion analysis, with one group for epithermal-neutrons and the second for thermal-neutrons [238, 737]. It should be kept in mind that the use of the diffusion theory, described in section 3.6.4, for this problem is an approximation. Strictly speaking the diffusion theory should not be used for determining the neutron flux near a boundary (due to the associated strong flux gradient near the surface), which is the case with a detector measuring the neutron flux on the surface of an object. Nevertheless, the diffusion analysis, with the help of some empirical measured parameters, can be used for preliminary analysis to identify the parameters that influence the response of the device. Such analysis can also be readily and more faithfully per-
Elemental and Content Analysis
577
formed with Monte Carlo simulations, see section 16.2. Regardless of the method used to analyze the performance of the device, it is customary to use calibration curves to relate the response of a detector to the hydrogen content, or some other related quantity. It is important to validate the calibration process periodically to ensure that the detector response does not drift as a result of some extraneous effects [738]. The slowing-down of neutrons was used to measure the concentration of carnallite in rock salt, making use of the high water-content of carnallite crystals [343]. The same technique was utilized for measuring the concentration of sulfuric acid in pipelines, by the hydrogen content of the acid. The technique was also applied to the measurement of hydrogen content per unit volume, hence the water content, of coal slurry [390]. Many applications has been reported for the use of neutron scattering for hydrogen as indicative of water content, moisture or wetness, see section 11.4. Backscattering of fast neutrons was proposed as a method for detecting plastic landmines, by the increase in the hydrogen content of explosive materials, and their casings, in comparison to soil [739, 740]. Similarly, a hand-held device is used for detecting hydrogenrich materials, such as narcotics, hidden behind panels made of steel, wood, fiberglass, and even lead-lined materials [741, 742, 743]. An interesting application of neutron moderation combined with a microwave moisture gauge was reported for determining the moisture and oil content in soil samples, to determine the extent of oil contamination and the effectiveness of a contamination process [744]. While the neutron-scattering measurement determines the total hydrogen content in soil (from water moisture and oil), microwaves measure only the water content; with the difference in the indication of the two gauges providing an estimate of the oil content. In order to enhance neutron moderation in a small (cylindrical) sample, an iron reflector of fast-neutrons was used to force fast-neutrons to pass the sample many times. Similarly, a microwave cavity resonator with a slit was used to cause the microwaves to pass through the sample repeatedly, enhancing the moisture measurement sensitivity. Lifetime. The lifetime, or die-away time, of pulsed fast-neutrons, discussed in section 11.3 for measuring porosity in geological formations, can also be used for measuring hydrogen content in extended media, since porosity is indicated by hydrogen which is predominately present in water and oil fluids filling pore spaces in rock. Neutrons slowed-down by hydrogen can be detected by the their late time of arrival to a detec-
578
Radiation Probing, Gauging, Imaging and Analysis
tor. Time-tagging neutrons can, therefore, be used to distinguish neutrons slowed-down by hydrogen from those fast-neutrons scattered by heavier elements. This process was proposed for the detection of landmines, by their higher hydrogen content compared to that of many types of soil [745]. By placing a small source within a fission chamber, a time-trigger is registered when the neutrons are emitted. Neutrons scattered back to a detector after some delay-time (about 5 ms), were considered to be slow-neutrons, the intensity of which is indicative of the hydrogen concentration. Neutron Transmission. Hydrogen content can also be measured with a neutron transmission technique. If a fast-neutron source is used, hydrogen will in effect “soften” the neutron-energy spectrum, as source neutrons will lose considerable amount of energy. Measuring the fastneutron flux is not as efficient as measuring slow neutrons. A thermalneutron detector can be used, but then one would be, in effect, measuring neutrons scattered in the forward direction. On the other hand, if a thermal-neutron detector is covered with a slowing-down material (such as polyethylene) to enhance the detection efficiency by slowingdown the incident neutrons, one would be measuring the transmitted fast-neutrons. However, the detector’s response will also be affected by the hydrogen content in the detector’s moderating material, which complicates the relationship between the detector’s count rate and the hydrogen content of the examined object. If the object does not contain a strong-neutron absorbing material, a thermal-neutron beam (extracted from a nuclear reactor or a neutron-thermalization assembly) can be used as a source in a transmission-based technique. Since hydrogen is a reasonably good neutron-removing element (by scattering and absorption) , the intensity of a beam will decrease exponentially with hydrogen content. This method is the essence of neutron radiography, as discussed in section 13.2. The method has also been used for measuring the voidfraction of two-phase (boiling-water) flow [481], and for measuring the asphalt-cement content of bituminous mixes by placing a sample in a stainless steel pan [746]. Using a source and an NE-213 organic scintillator, fast-neutron transmission was used for measuring the water content distribution in a soil layer packed in a column [747]. The content and distribution of hydrogen in graphite and in zirconium was also measured by the transmission of neutron beams from an isotopic source [748]. Thermal-neutron transmission is also used for hydrogen and water content measurement, due to the higher absorption cross-section of water in comparison to that of many materials. Example applications in-
Elemental and Content Analysis
579
clude measuring the moisture content in pottery [749] and in glass [750], studying humidity transport in building materials, and measuring the porosity of crystalline rocks for assessment of contaminant transport (with water filling the pores) [751]. The transmission of slow-neutrons was also utilized for measuring the hydrogen content in zirconium metal and to study the interactions between hydrogen and uranium [752]. Neutron-transmission, as the model of Eq. (6.2) indicates, is affected by the material density (which determines the macroscopic crosssection) and the material thickness. However, an associated gammatransmission, using the Neugat method described in section 6.5.3, can be used to account for these density and thickness effects. This method has been used for measuring the water content in wool, wheat, latex rubber, acrylic paint and alcohol, and the fat content of meat, dry wool and dairy products [343, 753, 754, 755]. The same method was also used for measuring the hydrogen content in coke, taking advantage of the fact that the transmission of fast-neutrons is mainly affected by the hydrogen concentration and mass per unit area (areal density), while gamma-transmission depends only on the areal density [640]. In source was the work reported in the latter reference, a collimated used, surrounded by a polyethylene moderator to slow-down and scattered neutrons back towards a detector, hence increase their detection probability.
12.3.2.
Scattering into Resonances
A neutron technique that is quite sensitive to the presence of hydrogen in small amounts, is known as the HYSEN (HYdrogen Sensitive Epithermal Neutron) technique [756], also referred to as the Notched Spectrum Technique [757]. As the name implies, the technique relies on the use of epithermal (0.25 eV to 1 keV) neutrons. Such neutrons are usually extracted in the form of a beam from a nuclear reactor, to provide the high neutron-intensity required for good sensitivity. The spectrum is then “notched”, i.e. part of its neutrons are removed, using a thick (3 to 6 mm) “filter” made of a material with a high absorption cross-section of neutrons within this energy. Materials that exhibit high (kilobarn) resonances in their absorption cross-sections include indium, silver and rhodium, see section 15.2.2.2. However, indium is the preferred filter material, because its most abundant isotope, (95.72 %), has a very high cross-section. Indium also is widely used as an activation foil to measure the thermal-neutron flux. A beam of epithermal-neutrons passing through a thick filter of indium, as schematically shown in Figure 12.3, will be depleted of neutrons in the energy range of 1 eV to 1 keV. By supplementing this filter
580
Radiation Probing, Gauging, Imaging and Analysis
with a thin (a mm or so) layer of cadmium, most of the sub-cadmium (< 0.5 eV) neutrons will also be eliminated. Therefore, the spectrum of the neutrons emerging after filtering would be cut–off below 0.5 eV and would be “notched” in between 1 eV and 1 keV. If these filtered neutrons are allowed to pass through a thin foil made also of indium (a 1 mm alloy of 0.05% In in then only neutrons in the energy range outside the windows of the filter (between 0.5 and 1 eV and above 1 keV) will be subjected to absorption by the foil, but at a lower rate due to the lower cross-sections outside the range of resonances. Therefore, this thin foil acts as a reference (background) indicator of the beam’s effect on the sensing foil, another thin foil placed behind the test target, as shown in Figure 12.3. Now if a hydrogen-containing target, say a metal, is placed behind the reference foil, the hydrogen in the target will slow-down some of the higher energy neutrons, thus filling in the “notch” in the spectrum. The metal, on the other hand, hardly affects the neutron energy. Therefore, the emerging beam will be richer in neutrons within the resonance range, and in the sub-cadmium (below 0.5 eV) range, where the cross-section is quite high. When this emerging beam of neutrons interacts with a second foil made also of indium, it will have then a high probability of activating the target. The neutron activation of leads to the
Elemental and Content Analysis
581
formation of which decays with a half-life of 54.29 min, releasing gamma energies that are easily detectable, say by a Na(Tl) detector. The dominant gamma-energies released and their relative yields are: 2.112 MeV (15.5%), 1.097 MeV (56.2%), 1.293 MeV (84.4%), 1.507 MeV (10.0%), 818.70 keV (11.5%), 416.86 keV (27.7%), where the percentage refers to the relative yield [12]. The amount of activation of the second (detection) foil, less that produced in the first (reference) foil, would then be proportional to the hydrogen content of the test target. The emitted photons can also be detected by a film positioned behind each detection foil to provide a radiograph. A modified arrangement of this method that enhances the signal-tobackground ratio, relies on detecting neutrons scattered off-the-beam, rather than those in the direct path of the beam. This can be achieved by using a hollow foil, with the opening diameter of the hole sightly greater than that of the beam [757]. In such arrangement, only neutrons scattered off-the-beam are detected. This arrangement reduces significantly the activation of the reference target and the detection target, by the source neutrons, since there are no longer subjected directly to the neutron beam. Moreover, since neutron scattering by hydrogen is in the forward direction (for single scattering), see section 3.5.1, scattering is favored in the direction of the detection foil. It was found that maximum activation occurs at a scattering angle of 60°. Thus by positing the annular target to detect neutrons scatters by between 45° and 80°, optimum activation of the target is obtained, while minimizing direct exposure to the source beam [757]. The metal, on the other hand, scatters neutrons isotropically but hardly affects, their energy. However, if the amount of hydrogen is sufficiently large to cause multiple scattering, some of the neutrons scattered by the hydrogen will reach the reference foil, increasing the reference signal, hence reducing the signal-to-background ratio. The method is sensitive to hydrogen levels in the range of parts per million [757] The HYSEN technique has been used for measuring hydrogen in steel, titanium aluminide intermetallic compounds (TiAl), obsidian, silicon, diamond and zirconium [758]. A variation of the HYSEN technique relies on the use of an iron filter. Unlike indium, silver and rhodium, which are strong neutrons absorbers in the keV range, iron allows neutrons of energy of about 24.5 keV to pass unaffected. This is due to the sudden decline in its scattering-cross section from an average value of about 12 b to about 0.5 mb. Therefore, subjecting a beam of neutrons to a thick iron sheet will tend to remove most of the neutrons of the beam, by scattering and absorption, except those with an energy of 24.5 keV, which will go through the shield virtu-
582
Radiation Probing, Gauging, Imaging and Analysis
ally unaffected. If this filtered monoenergetic beam is made incident on a test object also made of iron, it will pass though it unaffected, except if the iron contains hydrogen. Hydrogen will scatter the neutrons down in energy to anywhere from the beam’s energy to the thermal-energy, as dictated by the kinematics of neutron scattering, Eq. (3.81). If the hydrogen content is not too high, and the test object is not too thick, less say than 50 mm, source neutrons will tend to suffer no more than one collision, with increasing probability at scattering angels of 40° or more [759]. At a scattering angle of 40°, the neutron energy after a single collision of 24.5 keV, according to Eq. (7.15), is about 14.4 keV. Therefore, by positioning a detector capable of measuring neutron energy in the keV range at about 40° off the beam, one can monitor the amount of scattering by hydrogen, which is in turn proportional to the hydrogen content in the sample. Reference [759] reported measuring the hydrogen content of steel in the parts per thousand range, after unfolding the pulse-height spectrum of a proton-recoil gas detector to obtain the neutron energy. This method is also applicable to measuring the hydrogen content in other metals.
12.3.3.
Beta Particles
While all other stable nuclides have a ratio of about 0.5, for hydrogen is equal to unity, where Z is the atomic-number and A is the mass-number. This unique feature of can be exploited with electron-dependent radiation interactions, such as photons and chargedparticles, to detect the presence of hydrogen. A beta-particle technique was proposed, as early as 1954, to determine the hydrogen content in liquids [760]. This device, and similar systems, depend on the fact that the microscopic cross-section for inelastic scattering with the atomic electrons, which leads to the eventual absorption of beta-particles, is a function of the atomic-number for a given source energy, as the integration of Eq. (3.26) over all scattering angles indicates. Consequently the macroscopic cross-section, becomes a function of with where is the mass-density and u is the atomic mass unit. Since the energy distribution of beta-particles permits their attenuation to be approximated by an exponential function, with an attenuation coefficient, see Eq. (3.23), like is also a function of Note that the expression for in Eq. (3.24) does not include dependence on since for most elements is equal to 0.5. However in the presence of hydrogen doubles in value to unity and accordingly significantly increases, resulting in an increase in the attenuation of beta-particles for the same material density and thickness. The same concept can be used in principle with
Elemental and Content Analysis
583
Compton scattering, since its microscopic cross-section is also a function of see section 12.3.4. However, since the microscopic cross-section for photons is much smaller in magnitude than that of beta-particles, the latter type of radiation offers more sensitivity to changes in the hydrogen content. The measurement model for this beta-particle attenuation technique can be expressed with the aid of Eqs. (3.23) and (E.14), with A = 1 for H, as:
where I refers to the intensity of the incident radiation, is the intensity in the absence of the object, is the thickness of the object, refers is its to the weight-fraction of an element, A is its mass-number, microscopic cross-section, H refers to hydrogen, refers to other elements as in the inspected material, and u is the atomic mass unit. Since where is a the indicated above, is a function of Z, say microscopic cross-section per electron, then keeping in mind that Z = 1 for H, and for all other elements, Eq. (12.15) can be rewritten as:
with the last step made possible by the fact that since the summation excludes hydrogen. Therefore, the weight fraction of H in a test object of known thickness, and a pre-determined density, can be calculated from a transmission measurement by the relationship:
The model of Eq. (12.16) contains two main approximations; namely is element-independent and that for all elements other than hydrogen. While the latter assumption is not a bad one, particularly for light elements, the former assumption is not very adequate for elements of high Z value, where scattering by the electrostatic field of the nucleus becomes important, see sections 3.3.2 and 12.4.2. The nature of the chemical bonding of the material can also affect the value of However,
584
Radiation Probing, Gauging, Imaging and Analysis
for light elements, from Z = 1 to about Z = 10, beta-scattering by the is atomic electrons dominates, and it is reasonable to assume that independent of Z, since then according to Eq. (3.26). The model of Eq. (12.16) is also based on the exponential relationship of betaparticle attenuation, Eq. (3.23), which by is itself is an approximation. Nevertheless, the method has been used for measuring the hydrogen content in hydrocarbons, as they contain mainly elements of The hydrogen content can also be measured in the backscattering modality. Then the scattering response can be represented by the relationship [238]:
where use is made of Eq. (12.16), is the response for a sample of an is the response in the absence of the sample. infinite thickness, and is proportional to In the presence of elements of high Z values, Z, as scattering (elastic and inelastic) of beta-particles by the nucleus becomes more dominant, consequently Then the models of Eqs. (12.15) and (12.17) will have an extra Z-dependent term. While it can be accommodated this complicates the process of determined by prior calibration of the device’s response to the various expected elements in the examined material. It should be noted that due to the small depth of penetration of beta-particles, the use of the method is limited to the analysis of thin sample of liquids, about 2 mm thick. The sample needs to be housed in cells with thin windows made of a low density packing material, such as “Melinex”, to allow source particles to enter and leave the sample. The method is, therefore, most useful for analyzing hydrocarbons, which are binary mixtures of H and C for which the H/C ratio can be determined with this method.
12.3.4.
Compton Scattering
Compton scattering can also take advantage of the fact that is equal to unity for hydrogen, and is equal to 0.5 for all other elements, to determine the hydrogen content. As Eq. (3.51) indicates, the cross-section for Compton scattering is proportional to and thus for the same material density, the cross-section in the presence of hydrogen would be much higher than in its absence. This approach was used for determining the moisture content of wood chips [179], by monitoring the scattering of photons emitted from a source. This measurement is facilitated by the fact that the low moisture content of wood chips does not affect much its density, while it enhances its Compton scattering probability.
Elemental and Content Analysis
585
The same approach, also with a source, but in the transmission modality, was used for determining the hydrogen content of hydrocarbons; resulting in a linear relationship between the logarithm of the count rate and where is the material density and is the weight-fraction of hydrogen in the analyzed solution [24]. Multiple was used for measuring the density scattering of gamma-rays of and water content of soil [216], by taking advantage of the increase in the count rate caused by the doubling of the ratio in the presence of hydrogen.
12.3.5.
Cold Neutrons
Radiation responds mainly to the presence of individual atoms or nuclides, thus it provides elemental (rather than molecular) indications. Therefore, radiation techniques cannot, generally, sense the chemical bond in which a hydrogen atom exists. This should be kept in mind when detection water, which may be present as “free” or “bound” molecules. inherent in the composition of a material, while Bound water is the free-water is that due the water seeping through the material, such as moisture or in that in pores. Non-nuclear techniques such as the measurement of the dielectric constant, microwave absorption and magnetic resonance imaging can be used to discriminate between the two types of water, since their response depends on the chemical composition (molecular binding energy) of materials. However, quasi-elastic neutron scattering of cold-neutrons has been used to quantify the conversion of water from free to bound states, as in the hydration of Portland cement due to the interaction of water with tricalcium silicate [761]. Because of their low energy, the scattering of cold-neutrons is affected by the translation motion of water molecules, resulting in a difference in the scattering behavior of free and bound water molecules.
12.4.
Material Content Analysis
Content analysis aims at determining the relative content, or concentration, of known components of a material. The relative content can either be a volume fraction, or a mass fraction. For a mixture of components, the volume fraction of the the component, is where is the volume occupied by component and V is the total volume of the mixture. The mass fraction, of component is expressed as where and refer, respectively, to the density of component and to that of the mixture. From these definitions, one can show that
586
Radiation Probing, Gauging, Imaging and Analysis
Note that the quantity for a very small or amount of component is often expressed in parts per million (ppm). In order to be able to distinguish between different materials within a mixture, these materials must affect radiation in different ways. Unlike the elemental and composition determination described in sections 12.1 and 12.2, content analysis assumes that the nature of the material present in the mixture is known in advance. However, most techniques for elemental analysis can also be applied to content analysis, as shown in the ensuing sections, which address these methods according to the nature of the radiation used.
12.4.1.
Alpha Particles
Alpha-particle transmission can be used for detecting a binary mixture made of two materials of different densities, since the range of alphaparticles is dependent on the material’s density, see Eq. (3.14). The short-range of alpha-particles limits their use to gases, and necessitates performing measurements in a gas chamber within which the source and detector are placed. With a thick source, i.e. a source that self-absorbs some of the emitted alpha-particles, particles leaving the source will have an energy that varies from zero to the a maximum source energy, Then the dense component when present at a 100% concentration will stop entirely the transmission of alpha-particles through the sample, when the source-to-detector distance is equivalent to the range of alphaparticles in the gas at On the other hand, if the sample contains only the lighter component, the number of transmitted particles will be maximum. Therefore, in a binary mixture of the denser and the lighter components, the number of transmitted particles will depend on the relative concentration of the two components. One then would expect the count rate to vary linearly with concentration, so that the weightof the lighter component can be estimated as:
fraction, where
is the count rate at and C is the count rate at A surface-barrier semiconductor can be used to count the transmitted alpha-particles. It is important to maintain a constant gas pressure and temperature, or to correct for their change, since they directly affect the gas density. This method was used for controlling the mixing of helium and oxygen gases to a specified value [238]. An ionization chamber, see section 4.2.2.1, can also be used for measuring the relative content of binary and ternary gases. The measured ionization current, as shown in section 9.1, is a function of the ionization cross-section, defined by Eq. (9.1), which is in turn, like any macroscopic cross-section, is a linear function of the rel-
Elemental and Content Analysis
587
ative content of the two components of a binary mixture (see appendix E). This method was used for measuring the concentration of small amounts of added gases, such as CO, alcohol, and vapors of fatty acids in air [24]. This application is particularly useful for monitoring hazardous gases in the atmosphere of chemical plants and mines. The method was also used for analyzing mixtures of gases (hydrogen/nitrogen, hydrogen/ethylene, hydrogen/carbon-dioxide, nitrogen/nitrogen-dioxide, nitrogen/carbondioxide, ethylene/ether and helium/xenon) [24]. Ternary mixtures were also analyzed using two independent measurements. These two measurements can be attained at two ranges of operating voltage: plateau and low voltage (see section 9.1). Alternatively, two separation distances between the electrodes can be used to change the radius of the ionization zone, in Eq. (9.2). A nitrogen-hydrogen-ethane mixture was analyzed by this method using a small (28 mm diameter) and a larger (70 mm diameter) ionization chambers [24]. Alpha sources used in these applications include and
12.4.2.
Beta Particles
The strong dependence of the scattering cross-section of betaparticles, on the atomic number, Z, see Eqs. (3.26) and (3.28), can be used to distinguish between two components of various atomic-numbers in a binary mixture. One obvious advantage of beta-particles in a backscattering arrangement is that it is relatively easy to shield the detector from direct exposure to the source particles, because of the limited penetrability of beta-particles. However, the interrogated sample, if fluid or gas, has to be enclosed within a container of a thin widow to avoid absorption of the beta-particles by the walls of the container. Backscattering of beta-particles can also be made independent of material density by ensuring that the thickness of the inspected material is larger than the range of incident particles, so that all incident particles have a chance to interact within the medium. Then the amount of backscattering will be independent of the value of the range, hence independent of the material’s density. The number of backscattered beta-particles where Z is the atomic-number is approximately proportional to of the scattering atom [762]. Therefore, the amount of backscattered beta-particles is dependent on the composition of the scattering material. However, one must keep in mind that the domain of influence of such scattering measurement is within a distance that is no large than the particle’s range, thus any nonuniformity in the distribution of the mixture outside the range would be not be detected.
588
Radiation Probing, Gauging, Imaging and Analysis
A measurement model can be developed for beta-scattering with the premise that the amount of scattering depends on the macroscopic scattering cross-section of beta-particles in a mixture, For an object thicker than the range of incident beta-particles, the amount of absorption of beta-particles can be assumed to be constant, since the particles will be able to travel their entire range. Also since the range of betaparticles is small, the effect of divergence, Eq. (3.6.2), can be assumed to be about the same for all scattered particles. It is, therefore, reasonable to assume that the amount of scattered beta-particles is proportional to Since the microscopic cross-section of beta-particles is a function of the atomic-number, as Eqs. (3.26) and (3.28) indicate, then using for a mixture can be expressed as: Eq. (E.21),
where and refer, respectively, to the effective mass and atomic numbers of component, which can be calculated from the elemental values as shown in appendix E, and is a constant value that depends and nuclear on the relative importance of the atomic scattering effects, as determined by Eqs. (3.26) and (3.28). The approximation in Eq. (12.18) results from the fact that for most elements and materials (except pure hydrogen). Note that since for beta-scattering by atomic electrons, Eq. (3.26), the scattering crosssection, Eq. (12.18), is affected predominately by the nuclear scattering of beta-particles. As Eqs. (3.26) and (3.28) show, nuclear-scattering predominates over scattering by electrons by a factor of Z, and the two mechanisms of scattering have the same probability of occurrence only with hydrogen, Z = 1. Therefore, the presence of hydrogen can be distinguished from other elements and compounds by the virtue that its value is equal to unity, which enhances its scattering cross-section. This fact is used for the detection of hydrogen, as discussed in section 12.3. With the aid of Eq. (12.18), one can use the following model for the scattering of beta-particles in a mixture:
where is the measured detector response for component in the mixture when Obviously, one scattering measurement makes the technique only viable for measuring the content of binary liquids; with the relationship providing a second known quantity. Beta backscattering was used to measure the amount of dissolved salt in liquids, and the analysis of hydrocarbon liquids mixtures [238]. Refer-
Elemental and Content Analysis
589
ence [287] described an instrument, using a source and an ionizationchamber detector, for determining the hydrogen-to-carbon ratio in hydrocarbon liquids encountered in petrochemical processes, covering an H/C ratio from 1 (light fuel oil) to 2.5 (naphtha feedstock). The same method was used for measuring the ash content of coal, taking advantage of the fact that the effective atomic-number of ash is about 13, compared to 6 for the carbon of the coal. Finely-ground, air-dried coal samples were analyzed using the backscattering of a [323]. The method was also used for determining the tungsten content in iron [763]. Composition analysis of tin/lead plating on printed circuit boards by the beta-backscatter method, using a source, was also reported [764]. For materials with high Z, the sensitivity of the scattered radiation to changes in the atomic-number is not as pronounced as in the case of light materials where the change in the value of Z is quite high, see Eq. (12.18). However, using the energy of scattered beta-particles, one can segregate scattering by different elements. The maximum energy of the backscattered beta-particles depends on the atomic-number of the scattering element. Since the scattering cross-section of beta-particles increases with Z, see Eqs. (3.26) and (3.28), elements with higher atomicnumber scatter back beta-particles early in their passage through the material, thus scattered back higher energy beta-radiation before they travel deep into the medium. The maximum energy of backscattering was also observed to be independent of the energy of the incident betaparticles; provided that the incident beta-particles have an energy that exceeds the maximum-energy of backscattering [765], and that the material thickness is larger than the range of the particles in the material so that all beta-particles would have been subjected to scattering. The maximum energy of the scattered beta particles, is proportional where the value of varies from 3 [766] to 5 [765]. The latter to reference reported the following relationship:
Therefore, energy-discrimination can be used to determine the content of the element of the highest atomic-number in a sample, provided that its atomic-number is quite different from that of other present elements. This can be achieved by shielding the detector with a sheet of material (such as aluminum) that is sufficiently thick to absorb all beta-particles except those that are backscattered by the element of the highest atomicnumber. Then, the intensity of the detector response will be proportional to the content of the element of highest Z-value. This method is useful for the analysis of metal alloys and for the determination of the content of the additives with the highest atomic-number, such as tung-
590
Radiation Probing, Gauging, Imaging and Analysis
sten and molybdenum in iron, niobium in chromium, and lead in lead glasses [766]. The use of this method for the determination of iodine and mercury in aqueous solutions was also reported [179]. For a ternary mixture, two independent measurements are required, in addition to the relationship: where is the weightfraction of each species in the mixture. Beta-scattering, as discussed above, can provide one measurement. Beta-transmission can be used to provide the other measurement. However, beta-transmission measurements introduce two difficulties. First, for beta-transmission to be recordable, the thickness of the sample has to be less than the range of the source particles. This conflicts with the requirement of having a material thickness larger than the range to make beta-scattering independent of material density, as discussed above. Therefore, the transmissionmeasurement needs to be performed separately on a thin sample of the mixture. Even then one would be faced with the second difficulty of beta-transmission: the dependence of the transmission coefficient on the material’s density, as evident by Eq. (3.24). However, by performing an independent density measurement, say by simply weighing a known volume of the sample, the dependence on density can be accounted for. The combination of beta-scattering and transmission was used for measuring the relative weight fraction in ternary liquids of hydrogen, carbon and oxygen [767, 768], or hydrogen, carbon and fluorine [767]. Beta-particles are also used in ionization chambers for analyzing the content of gases, using the method discussed in section 9.1. This is the method widely used in gas separation by chromatography to analyze the content of the carrier gas [24]. Beta particles are preferred for this purpose because of their large range, which permits the surveying of a larger gas volume, allowing their use in industrial environments. As explained in section 9.1, the ionization current is a function of the ionization crosssection, defined by Eq. (9.1), which in turn, like any macroscopic crosssection, depends on the relative content of the two components in a binary mixture (see appendix E). Therefore, the method is directly applicable to the content analysis of binary mixtures from a single measurement of the ionization current. For multi-component mixtures, say of N components, N – 1 measurements are required, to determine the relative concentration of each component. Such measurements can be obtained by recording the ionization current at N – 1 stations, e.g., one at the plateau region (described in section 9.1) and the rest at lower voltages. This approach was considered for the analysis of gas, up to a five-component mixture and [24]. Beta-ionization and chambers employ one of the following beta sources:
Elemental and Content Analysis
591
Beta particles, emitted from sources such as and and directed into a stream of an inert gas (such as helium or argon) would lose their energy by inelastic scattering with the gas molecules and, when collected by an anode would produce a constant electric current. However, when an electron-capture gas is introduced into the steam, the slowed-down (to the thermal-energy) electrons would be absorbed by the introduced gas, lowering immediately the electric current. Vapors emitted from volatile compounds, such as nitrogen-based explosives, fertilizer and some household cleaners, produce such electron-capturing gases. Although electron-capture detectors cannot discriminate between different types of electron-capturing gases, when combined with chromatography, or other separation means (see for instance reference [769]), it can be used to characterize certain types of vapors, as those listed above.
12.4.3.
Photons
Low-Energy Transmission. For photons to be able to distinguish between different components in a mixture, they must interact differently with each component. This occurs when the components are sufficiently different to affect the macroscopic cross-section of photons. This most readily occurs at low photon-energy. A number of applications of the transmission and scattering of low-energy photons are discussed here. Low-energy sources are used for measuring the concentration of higher atomic-number elements in hydrocarbons, such as sulfur, lead and chlorine, due to the higher cross-section of these elements at low energy, see Eq. (3.30). Sulfur (one of the elements responsible for the acidification of rain when emitted as sulfur-dioxide during fossil-fuel burning) absorbs low-energy photons more effectively than carbon and hydrogen. For example, for photons emitted from a low-energy photon source of an average energy of about 5.9 keV (see Table 2.7), the total removal (incoherent scattering + absorption) cross-section for S is 11.2 kb/atom while it is only 0.213 kb/atom for C and 0.577 b/atom for H [19]. This large difference in cross-sections makes it possible to detect the presence of S in oil and organic materials through a radiation-transmission technique. A thin sample layer need to be used for this purpose to avoid full attenuation of this low-energy radiation. The same method is also useful for the detection of chlorine in hydrocarbon materials, since Cl has a removal cross-section of 14 kb/atom at 6 keV. Other low-energy photons, such as (22 to 26 keV), see Table 2.7, can also be used for this purpose. However, the same level of photon-energy can be produced by the bremsstrahlung of on zirconium (15 – 50 keV) or from beta-particles emitted from (18.6 keV maximum energy) as they travel through a heavy metal, such as zirconium, titanium in tritiated
592
Radiation Probing, Gauging, Imaging and Analysis
zirconium hydride or titanium hydride foils. This method was used for the measurement of sulfur content in the oil refining industry and for the determination of chlorine in liquid and epoxy plastics and chlorinated hydrocarbons [179]. With a slightly higher photon energy, the radiation transmission was same technique, with the 60 keV of used for the determination of heavy-metal salts (such as uranium) in solutions. Low-energy photon sources has been used for determining the content of a heavy element (Pb) in a light solution (gasoline and lead nitrate) [24], taking advantage of the enhanced contrast of lead absorption at low photon energy, Eq. (3.30). Both (photon energy less than 85 keV) and bremsstrahlung sources, on a uranium target (60-150 keV) and on antimony or on molybdenum (15-50 keV), were used for this purpose. Low-Energy Scattering. The scattering of low-energy photons can also be used for content analysis. The amount of scattered photons, though directly proportional to the mass-density for most materials (see section 11.1) is suppressed by photon absorption by the photoelectric effect. Since the latter effect is a strong function of the atomic-number, Eq. (3.30), materials with a high atomic-number scatter back less photons than those with high atomic-number. Therefore, the backscattering of low-energy photons can be used to distinguish between materials of different composition. This method, with a 85 keV photons from a source was used for determining the shale (ash) content of coal; taking advantage of the fact that while the atomic-number for coal is nearly equal to 6, the effective atomic-number of the mineral content (shale ash) is about 13 [762]. Low-energy sources used for this purpose (84 keV) and (60 keV) [24], (22 keV) [390] include and (13.60 keV) [323]. At these low energies, the medium can be considered to be infinite in size, allowing the use of the measurement model of Eq. (7.51). Then the scattering response of the detector, by the S, can by related to the fractional (per weight) ash content, relationship [390]:
where K is a system constant and and refer, respectively, to the scattering and total macroscopic cross-sections, per unit mass, of the designated material, estimated at some effective energy between that of the source and the detected photons (see section 7.5). The sensitivity of
Elemental and Content Analysis
S to changes in the ash content,
593
can be expressed as:
where use is made of Eq. (12.21). Reference [390] indicated that the highest sensitivity occurs at a source energy of about 15 keV, since the use of a source (13.60 keV). At lower energies, the probability of Compton scattering, see Eq. (3.51), is quite low to cause significant scattering, making it while at higher energies, Compton scattering dominates which reduces the contrast. One complicating factor almost equal to of operating at the optimum energy range is the interference of fluoroscopic emissions from iron, (see section 8.7), which has a K-absorption edge at 7.111 keV, that may overlap the energy range of the detected scattered photons. The strength of this high-intensity peak varies with the iron concentration, but it can be removed, at the detector side, by energy discriminating or by the use of an aluminum filter so that the increase in the count rate by Fe K-fluoroscopic emission is compensated for by the attenuation introduced by the filter material. The source energy determines the energy of the photons scattered within the medium, and in turn the amount of photons present at the excitation energy of the K x-ray of iron. Changing the source energy also affects the amount of fluoroscopic emission. It turned out that at 15.8 keV, the increase in detector counts due to fluoroscopic emission is offset by a decrease in the amount of backscattering, without the use of filtering or energy discrimination. According to Eq. (12.22), higher-energy sources, such as those emitted by (84 keV) and (60 keV), have a theoretical sensitivity to the ash content, but with such sources the scattering process is not fully saturated and the model of Eq. (7.45) should be used. Then the scattering response would be mainly sensitive to density changes, which can be correlated to the ash content [390]. Another factor that affects the measurement of ash content is the hydrogen (in moisture) content, which increases the value from about 0.5 for all other elements to 1 for H (where Z is the atomic number and A is the mass number). This enhances the amount of Compton scattering, by increasing The problem becomes, in effect, a three-component system of coal, ash and hydrogen. Using analysis similar to that of Eq. (12.22) for such ternary-component problem, reference [390] concluded that the optimum source-energy for maximum sensitivity to ash content would
594
Radiation Probing, Gauging, Imaging and Analysis
be between 60 keV and 22 keV In addition to measuring ash content, backscattering of low-energy photons was used for in situ measurement for the lithology (average atomic-number) of formations [716, 717], and for the determination of ash content in coal [770], see also section 12.2.2.4. Dual-Energy Transmission. Dual-energy (high and low) photon sources can be used, in the transmission modality, to determine the elemental content of a material composed of two elements, one has a high atomic number (Z), while the other has a low atomic-number. The presence of the high atomic-element is amplified at the low-energy due to its higher photoelectric cross-section, Eq. (3.30), while at high-energy the contribution of both elements is based only on their atomic-density. This method was used for the determination of the relative content of tin and lead in solder foils [24]; using a source (1.17, 1.33 MeV) and bremsstrahlung sources. The dual-energy photon or transmission technique was also used in the measurement of ash content in coal [640, 771, 772], by viewing the oil as consisting of two materials: hydrocarbons and ash and taking advantage of the fact that ash has an effective atomic-number greater than that of the coal matter. The sources employed for this purpose were: (59.54 keV) and (356.01, 302.85 keV) or (662 keV) [323, 640], or the two-energies source (22.6 and 88 keV) [773]. of a The dual-energy transmission method was used to determine the density and ash content of coal slurry, within a flow cell of constant and known thickness, using the 60 keV and the 662 keV energies, of respectively [390]. For a solid (coal plus ash) weight fraction, and and liquid (water) s, with an ash fraction and a coal fraction weight fraction, (1 – s), the transmission density can be expressed using the measurement model of Eq. (6.1) as:
where is the transmission intensity for an empty cell, is the mixture’s density, and is the macroscopic cross-section per unit mass (mass-attenuation coefficient), and is the thickness of the measurement cell. The low-energy transmission signal is dominated by the mineral (ash) content due its high atomic-number (about 13) and the subsequent prominence of the photoelectric effect, see Eq. (3.30). On the other hand, the high-energy signal is only a function of since the value of is not a function of the atomic-number, see Eq. (3.51) keeping in mind that for all elements except H. Therefore, the ratio of the transmittance, – In at low-energy to that at high-energy is
Elemental and Content Analysis
595
indicative mainly of see discussion around Eq. (12.22), while the If the ash content, is same value at high energy is indicative of known, then the ratio of the two transmission measurements can be used to determine the solid content, Alternatively, if the water content, is measured, e.g. by neutron slowing-down, (see section 12.3), then the two transmission measurements can be used to determine the ash content. Dual and triple energy transmission of photons emitted from an source was used for the determination of the purity of gold [774]. Dual and multi-energy gamma-transmission was also employed for measuring the volume-fraction of oil, water and void in multiphase-flow systems, see section 11.5.11. Rayleigh-to-Compton Scatter Ratio. The Rayleigh-to-Compton scatter ratio method, discussed in section 7.3.10, was used for measuring fat or water content in milk products or in meat [730], using the 60 keV photons of an source. The same technique was also used in the backscattering configuration to detect the elemental content of binary alloys (Ag-Cu, Sn-Cu and Au-Ag) with a source [728], taking advantage of the larger scattering angles (47° and 90°) for Rayleigh scattering attainable with high atomic-number elements, see Eq. (3.64).
12.4.4.
Neutrons
The absorption of neutrons can be used to determine the content of neutron-absorbing elements present within a less absorbing medium. Neutron absorption is highest at low energy, thus thermal-neutrons are usually employed for this purpose. Natural elements that have high, or reasonably high, thermal-absorption cross-sections include: lithium (70.7 b), boron (759 b), chlorine (33.2 b), cobalt (37.2 b), silver (63.6 b), cadmium (2.450 kb), hafnium (102 b), iridium (426 b), gold (98.9 b) and mercury (375 b); where the values in bracket is the thermal-neutron absorption cross-section for elements at their natural abundance [28]. In addition, some rare-earth metals are good thermal-neutron absorbers: neodymium (50.5 b), samarium (5.8 kb), europium (4.6 kb), gadolinium (49 kb), terbium (25.5 b), dysprosium (930 b), holmium (66.5), erbium (162 b) thulium (103 b), ytterbium (36.6 b) and lutetium (77 b). Neutron absorption can be monitored either directly by its effect on the population of incident thermal-neutrons, or indirectly by the characteristic gamma-rays promptly emitted following neutron capture. The latter approach is discussed in section 12.1.1.1, and provides the ability for discriminating between various neutron-absorbing elements that may be present in a medium. However, when the inspected medium is
596
Radiation Probing, Gauging, Imaging and Analysis
a mixture of a highly-neutron absorbing material and a weak-absorbing substance, it is advantageous to directly monitor the thermal-neutron flux. This is because the neutron absorption cross-section is higher cross-section, as the former incorporates all than the capture neutron-absorption reactions, such as the (n,p), (n,d) and reactions. Thermal-neutrons are also easily measurable using one of the detectors discussed in section 4.4. Since readily available neutron-sources are fast-neutron emitters, thermal-neutrons need to be generated by slowing-down fast-neutrons. However, the moderation process (see section 15.3) can be incorporated in the design of the device. Thus, three possible basic configurations for a neutron-absorption device can be configured, as schematically shown in Figure 12.4, and discussed below.
Elemental and Content Analysis
12.4.4.1
597
Transmission
The most direct way to the determination of the content of a neutron absorber in an object is to subject a thin sample of the object to a beam of thermal-neutrons, as schematically shown in Figure 12.4.a. The object has to be thin to avoid complete absorption (blackness) of the beam, since the beam is attenuated exponentially according to Eq. (6.1). Therefore, for a binary mixture of a strong neutron absorber of weight and a weak absorber of weight fraction, the measurefraction, ment model of a neutron transmission device can be expressed as:
where I is the intensity of the transmitted beam at thickness and is that for zero thickness, and A refer, respectively, to the microscopic thermal-neutron and mass-number of each component, is the mixture density, is the thickness through which the neutrons are transmitted, and u is the atomic mass unit. In arriving at the model of Eq. (12.24), use is made of Eq. (E.14) and it is assumed that absorption is the main should neutron-removal process; otherwise the total cross-section, The model of Eq. (12.24) indicates that if the be substituted for thickness of the object and the basic nuclear properties of its can be determined, two components is known, the weight-fraction, provided that the density is also known. If the latter is not known, the transmission measurement will provide an estimate of which can be expressed in terms of parts per million. For optimum statistical counting conditions, the thickness, should be such that the absolute value of the argument of the exponential function in Eq. (12.24) should not exceed the value of 2, when evaluated at maximum expected concentration of an absorber, see section 14.2. This thickness can be quite small for a strong absorber. Moreover, extracting a thermal-neutron beam requires a bulky moderating assembly or a nuclear reactor. Thermal-neutron transmission is most often used in neutron radiography, as a qualitative indicator of the presence of absorbers, see section 13.2. The technique is also used in cross-section measurements of materials, see for example references [775, 776, 777]. The system set-up for such measurements can be useful in devising neutron-transmission systems. The use of thermal-neutron transmission has also been reported, for determining the water content in materials, see section 12.2. Transmission of fast-neutrons directly emitted from isotopic sources is also used in content analysis when the cross-sections of the components
598
Radiation Probing, Gauging, Imaging and Analysis
involved is sufficiently different. In addition to measuring hydrogen content, as indicated in section 12.2, the method was, for instance, used for the analysis of silver concentration of coins [778, 779].
12.4.4.2
Flux Depression
The transmission method discussed in section 12.4.4.1 above is useful when a beam of thermal-neutrons is available, say from a nuclear reactor, or an existing thermalization facility. However, if a new system is to be designed using an isotopic source, constructing a thermalization assembly and extracting a beam from it, is not the most effective process of utilizing a source, since only a small fraction of the source neutrons will be thermalized and extracted by a beam port. It is more efficient to insert the inspected material, or a sample of it, within a thermalization assembly containing a moderating material around a fast-neutron source, as schematically shown in the left-hand-side configuration of Figure 12.4b. Of course, if the inspected material itself is a moderating material, there is no need to use a separate moderator, as shown in the right-hand-side of Figure 12.4b. In the latter configuration, it is possible to place the source and detector in the same enclosure (providing a compact device), since thermal-neutron detectors are not very sensitive to the source’s fast-neutrons. In either case, the moderating material slows the source’s fast-neutrons, creating a “cloud” of thermal-neutrons within the assembly. The presence of material containing a strong neutron absorber will create a depression in the neutron flux, that can be measured with the aid of a thermal-neutron detector inserted either in the proximity of the inspected object, or if possible within the object itself. The amount of flux depression would then depend on the concentration of the neutron-absorbing species in the inspected object. A measurement model can be developed to estimate the amount of flux depression, using the equations presented in section 9.3. However, the modeling process is approximate. Therefore, it is more convenient to calibrate the detector using samples of various known concentrations. This flux-depression method was used for the determination of the boron content in samples of the feedstock of a plant producing a heatresistant (refractory) material [289]; since the presence of boron at high concentration lowers the strength of the material due to the migration of the small boron atoms through the material as it is heated. The method can also be used to measure the concentration of boron in metal alloys (added to improve hardness), glass, glass-reinforced plastics, mineral,
Elemental and Content Analysis
599
rock, detergents3, etc; and cadmium in metals and their alloys and in zinc solutions, etc. [24]. The method was also used for measuring indium in tin, hafnium in zirconium, gold in copper, tantalum in niobium, manganese in aluminum and cobalt in iron [24]. Flux depression can also be used to determine salt (NaCl) content in an extended water medium, with the water providing the moderating material and chlorine being the thermal-neutron absorber [238]. The same method is applicable to the measurement of aqueous salts that contain boron, cadmium, potassium, silver and iron. Note that although the latter two elements are not good absorbers of thermal-neutrons, theirs microscopic cross-section is much larger than that of water: 2.07 b and 2.62 b for potassium and iron, respectively, and 0.66 b for water [28]. The technique was also used for measuring the gadolinium content in the presence of other rare-earth elements [24].
12.4.4.3
Backscattering
If the mixture containing the neutron-absorbing material also contains a neutron-moderating material, the latter can be used for slowing-down the fast-neutrons of the sources thus eliminating the need for a separate moderating assembly or an external beam. This provides flexibility in locating the neutron detector, which can be inserted within the inspected medium itself or located outside of it. However, the latter arrangement is preferred as it enables passive and on-line inspection of an object. This arrangement, as schematically shown in Figure 12.4c, allows the use of a fast-neutron source and the measurement of backscattered slowneutrons. The source and the detector can be placed in the proximity of each other, since thermal-neutron detectors are not too sensitive to fast-neutrons. This not only provides a compact device but also enables “one-side” inspection, an added flexibly. An empirical measurement model for this backscattering method is given by [781]:
where is the detector response at concentration of the absorbing material, is the response at zero concentration, is a system constant, and and are attenuation constants, per unit concentration of absorbing material, the value of which depends on the nature of the 3
The use of borate as a builder in laundry detergents sequesters calcium ions, lowers the interfacial tension between fatty soils and water, enhances the negative surface charge characteristics of pigment soils and provides the wash liquor with alkalinity and significant pH buffering capacity; all have a beneficial effect on detergency performance [780].
600
Radiation Probing, Gauging, Imaging and Analysis
moderating materials. The parameter in Eq. (12.25) can be viewed as the intensity of the thermal-neutron “cloud” created within the material. The number of neutrons reaching a detector is then attenuated The deviation from this simexponentially with increasing value of ple exponential behavior, the second term in Eq. (12.25), is caused by the fact that the “apparent” size of the thermal-neutron “cloud” is affected by the concentration of the absorbing material. At low values of neutrons far away from the detector can still reach it, while at very high concentrations these neutrons would be absorbed before reaching the detector. That is, at low concentrations, the “cloud” appears to the detector to be larger than it would have been at high concentration where the absorbing material in effect masks the far-way neutrons. The second exponential term in Eq. (12.25) is, therefore called the “visibility” term [781]. At high concentrations the value of the visibility term becomes negligible, and the detector response changes exponentially as Therefore, the value of can be determined by the slope of as it the line that best fits the logarithm of the detector response, In varies with at high concentrations, while the value of is determined axis. At low concentraby the intersection of this line with the tion, the intersection of the best-fit line of with the while the constant is simply the detector response is Obviously the value of has to be greater than that of for at the thermal-neutron “cloud” to become invisible at high concentration. This indicates too that the detector response at low value of is quite sensitive to small changes in that is, the device has a better contrast at low absorber concentrations, often a desirable feature.
Neutron backscattering has been used for on-line measurement of boron in boric acid in an effluent solution in a nylon processing plant [289], with the hydrogen and carbon of the nylon acting as the moderator. A device was designed for monitoring the gadolinium concentration in the shutdown system of a CANDU reactor [781, 782]. CANDU reactors inject gadolinium nitrate dissolved in heavy-water into the reactor as one of two methods for terminating the nuclear chain reaction (the other method is the injection of cadmium rods). The gadolinium solution is stored in tanks, and is injected into the reactor, when needed, via pipelines connected to the reactor. The backscattering method provides a simple method for continuously monitoring the gadolinium concentration in the tank to alert reactor operators to any changes in concentration.
Elemental and Content Analysis
12.4.4.4
601
Neutron Die-Away
The neutron decay-time technique, discussed in section 9.4, can be used to measure the macroscopic cross-section of thermal-neutrons in an extended medium, such as rocks. The neutron lifetime in rock is 900 ms for quartz, but is only 5 ms for saline formation water (due to the presence of chlorine in the latter) [40]. Thus the lifetime of thermalneutrons is used to discriminate between salt water and oil, in petroleum explorations. Typically a 14 MeV pulsed-neutron generator is used for this purpose. Such generators are compact and can be gradually inserted into a borehole to examine a formation at various depths. Fast-neutrons are eventually slowed-down, mainly by the hydrogen in the formation, to the thermal-energy, and then begin to dissipate at a rate that depends on the thermal-neutron macroscopic-absorption cross section, according to the measurement model of Eq. (9.13). The thermal-neutron population can be measured directly with a thermal-neutron detector. However, such measurements would provide only local indications from the area surrounding the detector, since thermal-neutrons from farther away would be absorbed in the formation before reaching the detector. Therefore, the thermal-neutron population is recorded directly by the gamma-radiation resulting from its capture. Such gamma-rays have a higher penetration depth than thermal neutrons, thus provide a more global indication of the thermal-neutron population, covering a range of about 0.35 m [40]. Either gamma-rays of energy above 2.223 MeV (produced by the capture of thermal-neutrons by hydrogen), or all photons of energy above 50 keV, can be recorded. The former has the advantage of avoiding counting background gamma-rays from natural radioactivity (see section 8.8.2) and scattered photons, while the latter produces a higher count rate but requires correction for the gamma-ray background [40]. By measuring the neutron population at two different time intervals, the decay time of the thermal-neutrons can be determined, which in turn enables the calculation of the macroscopic absorption cross-section, using Eq. (9.14). Alternatively, the decay time-constant may be measured by determining the relative decay rate is the change in the count-rate over a period and N is where the average count rate within this interval. This is a finite-difference approximation of Eq. (9.12), which provides an estimate of for a as determined by the temperature of given thermal-neutron velocity, the medium (see section 3.5). However, this finite-difference approach is not practical since it requires a very small value of to provide an adequate estimate of the decay rate. To overcome this difficulty, a dynamic self-adjusting approach is used, as explained below.
602
Radiation Probing, Gauging, Imaging and Analysis
If the count rate is measured at two consecutive time intervals, one starting at time and the second interval over a period over a period starting at time then using the exponential measurement and in these two inmodel of Eq. (9.13), the resulting counts, tervals can be related to each other as:
When as Eq. (12.26) shows, Therefore, the dynamic adjustment approach uses a series of pulses, and estimates the ratio in each pulse. With an electronic circuit, the value of is adjusted so that approaches a value of 2, during the next pulse. The process is repeated until then which enables the determination of The electronic signal maintains the value of until the value of changes and the process is repeated. This is the process used in one of the thermal-neutron decay tool of Schlumberger [40], which employs a source that provides a pulse of a duration of every where the value of which determined as explained above. When a second detector is added to such instrument at a position far-away from the first one, the ratio of the counts of the two detectors (near/far ratio) is indicative of the formation’s porosity. Since porosity in rocks is related to the hydrogen content, as explained in section 12.3.1, this ratio is nearly indicative of the hydrogen content. The reason being that neutrons reaching the far-detector are faster neutrons since they would have managed to travel a longer distance without being slowed-down and captured. Therefore, the higher the count rate of the far-detector, the less slowing-down neutrons would have suffered, hence the lower is the hydrogen content. Scaling the far-detector count rate by that of the near detector compensates for the local absorption of neutrons. The inverse of this scaled quantity becomes then indicative of porosity [40]. Thus aside from measuring a thermal-neutron dieaway tool also provides a measure of porosity. Note that a low porosity indicated by such a device may also be due to the presence of a gas, because of the low hydrogen-density in gases. The lifetime, or die-away time, of neutrons slowed-down from 14 MeV to the epithermal energy range was also used to measure the hydrogen content in geological formations [783]. A detector, covered with a gadolinium foil to cut-off thermal neutrons, was used to record the slowing-down of 14 MeV neutron pulses. The advantage of measuring
Elemental and Content Analysis
603
epithermal-neutrons, rather than thermal-neutrons, is that epithermalneutrons are less sensitive to the other neutron-absorbing materials that may be present in the surroundings, such as chlorine. The method is particularly useful when examining air-filled holes and formations where strong thermal-neutron absorbers, such as boron and gadolinium, are present [784]. The neutron die-away method can also be used for detecting fissile materials in nuclear waste drums using a pulse of 14 MeV neutrons [785]. As these neutrons are slowed-down in the drum and by the surrounding material, they would induce fission. The presence of neutrons after the termination of the pulse is then indicative of the presence of fission materials (as small as 1 mg of and However, since the amount of thermal-neutrons produced is greatly affected by the presence of neutron moderating and absorbing materials, reference [785] suggested relying as well on measuring the fission induced by epithermal neutrons. The latter fission is dominant within a short time-period (about 100 following the termination of the pulse.
12.4.4.5
Neutron Activation
Although the neutron-activation techniques discussed in section 12.1.1.1 aim mainly at detecting specific elements, multi-elemental analysis can be used as an indication of the presence of a certain material. For example, contamination of food stuff with soil can be distinguished by the presence of aluminum and silicon, with the two elements detectable by the production of via the thermal-activation reaction These two and the epithermal/fast neutron reaction reactions were used for monitoring the soil content in shredded sugar cane (soil is introduced by modern cane harvesters) [384].
12.4.5.
X-ray Fluoroscopic Emission
The x-ray fluoroscopic emission (XRF) discussed in section 8.7 can also be used for content analysis, by focusing on one element, rather than on many elements as it is the case with elemental analysis, discussed in section 12.2.1. Since the x-ray emission from elements of low atomic-number is lower in energy than that of high atomic-number materials, XRF is particularly useful for measuring the content of metals in hydrocarbons, e.g. iron and cobalt in lubricant’s and silver content in photographic emulsion [179]. A compact XRF device was also used for determining the total sulfur content in coal samples, using as an excitation source and a krypton-filled proportional counter as a detector [786, 787, 788]. The same approach was also used for measuring the content in ambient air and in stacks of a tobacco curing plant [789].
604
Radiation Probing, Gauging, Imaging and Analysis
Uranium enrichment, i.e. the concentration of in enriched uranium is determined by measuring the 186 keV peak and comparing its intensity to that of a standard sample; or by thorough analysis, using a highresolution detector, of the uranium K x-ray profile in the region 89 to 100 keV, where both and have characteristic peaks [790]. The x-ray fluorescence method (EDXRF) was also used to determine the lead concentration in aerosol samples [791]. Lead concentration on painted surfaces was measured in situ using and to excite the lead characteristic x-ray, with the emissions measured using an detector [792].
12.4.6.
Mössbauer Spectroscopy
As indicated in section 6.5.5, the Mössbauer technique is most useful for determining the iron content, since natural iron contains 2.1% and the latter isotope has a strong recoilless-absorption of gamma-rays at room temperature. However, using indirect indications, the technique can be used to determine the concentration of alloying elements in steel carbides and two-phase alloys (such as Fe-Ni-Cr, or Fe-Ni-Mn) [178]. The method is also useful for distinguish between different phases of steel, such as ferromagnetic ferrite and paramagnetic austenite phases, or different steel alloys [178]. In particular, the determination of retained austenite in steel, a quantity that directly affects the quality of steel, can be determined with Mössbauer Spectroscopy. Amorphous ferromagnetic alloys are uniquely studied by this technique, as it provides characteristic spectrum patterns that can be used for studying the crystalization process of amorphous alloys and the amount and location of hydrogen introduced into the alloy [178].
12.4.7.
Natural Radioactivity
Airborne gamma-ray is routinely used to produce maps of natural background activity from K, U and Th. A large volume (50 L) NaI(Tl) detector mounted on an airplane flying at height of about 120 m on a spaced grid lines can produce such maps, enabling the discovery of uranium deposits [348, 793, 794]. Surveys of seabed, using an HPGe detector, has been also useful in identifying areas of deposited radionuclides from the outfall of nuclear reprocessing plants [348].
12.4.8.
Combined Techniques
Content analysis sometimes requires the application of more than one ND E technique. This is illustrated here by considering the case of the bulk analysis of coal, one of the materials for which radiation techniques
Elemental and Content Analysis
605
for content analysis are well-developed [640]. The discussion here is based on references [554] and [640] Coal consists of the basic coal matter (C, H, O, N, S), ash (incombustible minerals, such Al and other silicates), inherent moisture (bound water) and free moisture (from external wetness). The main combustion parameter is the energy released per unit mass (also called caloric value or specific energy), which is directly related to the carbon content. The coal’s ash and moisture content also affect its combustion. Using elemental analysis with the fast-neutron prompt-gamma activation method (see section 12.1.1), the carbon and hydrogen content can be determined [554]. The density of a bulk amount of coal can also be measured with backscattering of gammarays, see section 11.1. The carbon content and the coal’s bulk density can be correlated to its specific energy. For a particular type of coal, the C/H ratio tends to be constant. Therefore, the presence of moisture will introduce an excess of hydrogen, and hence reduce the C/H ratio. This ratio along with the coal density can, therefore, be related to the moisture content of the coal. This correlation fails, however, if the moisture content is high, as the associated increase in the hydrogen content affects the coal’s density, and it also reduces, by slowing-down, the amount of fast-neutrons available for activating the carbon of the coal, which in turn affects the estimated H/C ratio. The slowing-down of fast-neutrons, see section 11.4, can then be used to measure the moisture content. The determination of ash content can be obtained from the prompt emission of 1.78 MeV gamma-rays by the inelastic scattering of fast-neutrons. Alternatively, an increased ash content would increase the bulk density of the coal due to the increased mineral content. This in turn tends to affect the overall carbon and hydrogen content, allowing the correlation of the three parameters (density, C and H activation yields) with the ash content [554].
This page intentionally left blank
Chapter 13 IMAGING
13.1. 13.1.1.
Photon Radiography Film Radiography
Film photon (x-ray or gamma-ray) radiography is used in numerous industrial applications: for inspecting welds in fabricated structures and in pressure vessels, establishing the soundness of cast products, and for the detection of flaws, void spaces and inclusions. In welds, radiography can detect hot tears, shrinkage cracks, trapped gas (blowholes), slag inclusions, lack of fusion, and lack of penetration. In castings, pipe (round cavities at center of an end surface), shrinkage, hot tears, blowholes and sand or slag inclusions may be detected [795]. Although radiography is conventionally used for flaw detection, it is also useful for inspecting process equipment for trouble shooting, such as for detecting flow blockage [286], determining the position of a frozen valve and measuring the extent of corrosion or scale buildup inside pipes and containers, etc. [238]. Radiography is particularly useful for detecting corrosion in irregular regions, such as areas of pipe around welds [286]; the higher penetrability of gamma-radiography is advantageous in this regard. In light materials, such as graphite and beryllium, it may be difficult to detect small cracks and voids, because of the small difference in radiation attenuation between the material and void. However, the contrast of a radiograph can be enhanced by soaking the object in a liquid containing heavy elements, such as carbon tetrachloride [179], that penetrates into the defects and enhances radiation attenuation within the void space. Radiography is also used in quality assurance and product assessment, as for example in the pre-deployment 607
608
Radiation Probing, Gauging, Imaging and Analysis
assessment of conductive tether of the Tethered Satellite System Reflight (TSS-1R) [796]. X-ray radiography of composites has been used to examine glass and boron-fiber reinforced materials for volume-fraction and fiber alignment [797, 798]. However, radiography of carbon-fiber reinforced composites is more difficult, because of the small variation in density of the material in the composite, and their low-density which does not make them amenable to photon absorption. Nevertheless, some attempts have been made to overcome this hindrance, by for example incorporating lead-glass tracers in the fiber material to increase photon absorption [799]. Detection of delamination by transmission-radiography is almost futile, due to the integrated (along the radiation path) nature of radiographic indications. Also debonding of adhesive joints when made with metal adherends is quite difficult to detect. While the presence of metal masks the low-density adhesive material, the void space created by debonding does not affect the intensity of transmitted radiation. The latter problem can be overcome with a scattering technique (see section 10.2), while neutron radiography (section 13.2) provides sensitivity to hydrogen-rich adhesives. Gamma-ray sources, mainly and are widely used in industrial radiography. However, unlike x-ray machines which tend to emit photons in a confined direction, isotopic sources emit radiation in all directions. Therefore, while performing radiography with these sources, access to the radial area around the source must be restricted for safety reasons. However, using a source collimator, the incident radiation can be confined to only the part for which it is necessary to produce a radiograph. This results in an intrinsically safe system with significantly reduced radiation controlled-access area (during exposure), see for example the radiography system reported in reference [800].
13.1.2.
Radioscopy
The term radioscopy is used to refer to real-time, and near real-time, non-film detection, display, and recording of x-ray and gamma-ray images. Standards and guides for radioscopy are available [801, 802, 803]. Real-time radiography is the term more often used to refer to radioscopic systems, but the method is also known as fluoroscopy [7, 134]. Real-time radiography provides an immediate visible image of the inspected object. This is accomplished by projecting the transmitted radiation on a fluorescent (zinc-sulfide or cesium-iodide, sodium dopped) screen, which illuminates visible light with an intensity proportional to the intensity of the incident radiation. The viewer is protected from direct exposure to radiation by covering the back of the screen with a thick sheet of spe-
Imaging
609
cial lead glass. The use of fluorescent screens though convenient comes at the expense of reduced image quality (spatial resolution and material contrast), in comparison to film radiography, due to the coarser grained structure of the screen and its low contrast gradient and the lower optical contrast [7]. But the main limitation of fluorescent screens is the low brightness of the image, which makes it difficult for the eye to observe fine image details. However, images can be enhanced with the aid of an intensifier tube. The light from the fluorescent screen bombards a photocathode to generate electrons that are accelerated by an applied high-voltage to produce a small but very intense visible image on a fluorescent screen inside the image intensifier. The image can then be viewed through a television monitor or recorded by a camera. An image on a fluorescent screen can be photographed with a camera to produce a permanent record. The process is then called photofluorography [134]. However, the image details and resolution can be severely curtailed in this process. Video camera can also be used to capture the radioscopic image to produce a motion picture, in a process known as cinefluorography [134]. Perhaps the most widely encountered application of real-time radiography is screening carry-on passenger baggage at airports. In order to reduce the exposure to photographic films that may be present in the baggage, a short-duration pulse of x-rays is used. Such systems typically employ a fixed vertical linear array of photodiodes to detect the transmitted x-rays when the baggage traverses the radiation source as it travels on the conveyor belt [7]. The recorded measurements are electronically amplified, stored and enhanced, then displayed on a television monitor. This method of image recording does not, however, produce the fine details required in industrial applications for flaw detection in welds and castings. A number of industrial applications have made use of real-time radiography. Reference [7] cites the following examples: high-speed inspection of welds: submerged-arc welds in shipyards, pipe-welds on lay barges and in construction yards; sorting of casting such as automobile wheels; inspection of rubber tires for correctness of metal insertions; observing the flow of molten liquid during castings; inspection of rocket motors and radioactive waste drums using a large gamma-ray sources; and even the radiographing of a full-sized aero-engine running on a test-bed using a 8 MeV accelerator. Some recent applications in this and other areas are discussed below. On-line inspection of arc welding with real-time radiography makes it possible to study and control the welding pool and the heat-affected zone during the welding process. It becomes then possible to detect, and
610
Radiation Probing, Gauging, Imaging and Analysis
monitor on-line, defect formation in the weld and to study metal fusion and filler-metal/base-metal interaction and metal transfer in the welding pool. Radioscopy may also be used for post-service real-time remote testing of weld quality, using information on weld quality received from automatic recognition of real-time radiographic images. For example, an arc welding process control was developed using radiography as a feedback [804, 805, 806, 807]. Real-time radiography was also considered for offshore use to inspect under-water pipelines and assess the quality of circumferential welds [808]. Radioscopy was also used for inspecting manufactured casts, to detect defective castings and to obtain information, on the type and position of defects, that can be relayed back to operators for correction [809]. Monitoring the evolution of molten-liquids is another attractive application of radioscopy. A number of applications have been recently reported in this regard. Molten liquid visualization applications include: monitoring bismuth flow through filters placed in the mold, used in the casting industry to physically remove inclusions in the material and improve the fluid flow within the mold assembly [810]; observing natural convection flow during melting and solidification of a gallium-indium alloy [811, 812, 813]; viewing crystal/melt to study interface dynamics during indium antimonide crystal growth [814, 815, 816, 817]; following the density-field of a layer of liquid gallium, laterally confined in a small cavity, heated from below and cooled from above [818]; examining the flow of a polymer-resin-fluid through a volume of a reinforcement material (fiber glass mats or fabrics) in manufacturing matrix composite materials [819]; and studying liquid-metal behavior in molds of stainless steel and gold [820]. Radioscopy has also proven to be useful for in situ monitoring the progression of wear and damage; as it was used for example to study the effect of laser surface alloying of Ni, Cr on the fretting wear behavior of 6061 aluminum alloys [821]. The terminal damage state of notched composites over a wide range of cross-ply graphite reinforced epoxy specimens was also monitored with real-time radiography [822], which enables the studying of damage initiation and evolution processes in highly filled polymeric material under various loading conditions [823]. Highresolution real-time digital radiography makes it also possible to detect corrosion and cracking in hidden structures of aircraft [824], as well as in turbine-engine components, and composite materials [825]. With realtime radioscopy, it is also possible to examine economically long sections of insulated piping [826], rather than relying on the tedious process of film-based radiography. A real-time digital radiographic examination system, that utilizes a linear array of solid-state detectors instead of a
Imaging
611
film, was developed to aid in the detection of flow-accelerated corrosion and other wall thickness degradation in insulated or uninsulated piping systems [827]. Other example applications of real-time radiography include: investigating the macrostructure of high-temperature superconductors [828]; determining the slag accumulation (slag pool depth as a function of time) in the aft end of the Titan solid rocket motor upgrade [829]; and examining solid rocket motors to obtain information about propellant burning and cracking [830].
13.1.3.
Flash Radiography
Flash radiography is used to record images in a very short duration (a few microseconds). The technique is also known as high-seeped radiography [134]. This is achieved by the use of a pulsed source of radiation. In order to obtain a good quality image within such a duration, the radiation beam has to be very intense. Such a high intensity x-ray source requires a very intense electron beam (as high as 2000 amp), which is in turn produced by the application of a very high-voltage pulse and the use of pointed (needle shaped) cathodes (to increase the current density at the surface of the cathode) [4, 7, 135]. A high-power laser pulse can also be focused onto a solid or gaseous target at very high intensities to produce relativistic and MeV electrons and ions that, in turn, produce x-rays. High-intensity, high-energy photons can also be produced in a linear accelerators, as in the case of the Flash X Ray, or FXR, system of the Lawrence Livermore National Laboratory [831]. Flash radiography enables the imaging of items in motion, by recording rapid sequential images. Therefore, most applications of flash radiography are in imaging events in motion. Some recent examples of these applications are given here. In impact studies, flash radiography was used to image debris resulting from the impact of solid spheres into thin plates to study the impact failure and fragmentation properties of the material from which the spheres were made (tungsten carbide, steel, copper, aluminum, tantalum or titanium) [832, 833, 834, 835]. The technique was also used to study the state and velocity of thin titanium plates accelerated to high velocities (10.3 - 10.9 km/s) with an explosive three-stage launcher to examine their integrity during the acceleration process [836]. The motion of long tungsten projectiles fired against unconfined alumina targets with steel backing was photographed with flash radiography to study the influence of scaling the dimensions of the projectiles [837]. Also, the movement of a 0.5-1.0 g aluminum fragment launched at a speed of 11.2±0.2 km/s was observed in-flight with flash radiography, to study the effectiveness of its launcher [838]. Flash ra-
612
Radiation Probing, Gauging, Imaging and Analysis
diography was also used to observe, and determine the volume-fraction (void fraction), of steam, produced when water interacts with melt or high temperature solid clouds [839]. Flash radiography is useful for imaging jet formation and propagation. Example applications include: studying the penetration of a copper jet in Plexiglas [840]; characterization of jets produced by explosive charges [841, 842]; and for investigating jet-driven circulating flow in closed liquid-metal combustion [843]. Flash radiography was also used to study the internal processes of closed liquid metal combustion systems [844]. The radiographs obtained from flash radiography can be used to interpret dynamic events, by simple visual observations, or extracting density information from the digitization of the radiographs. Examples of quantitative analysis of flash radiographs for shock-wave hydrodynamics analysis are given in reference [845]. With soft (low energy) flash x-rays, lower density materials can be imaged. For example, with soft x-rays it was possible to image the flow of argon streams in ambient air [846], and to visualize flow phenomena (entrainment and streamlines) in coating flows [847]. Images of air bubbles in an old newspaper fiber suspension [848] and in bleached softwood kraft pulp suspensions were also obtained with flash radiography [849].
13.1.4.
Microfocus Radiography
As discussed in section 6.3.1.2, penumbra is one of the factors that affect the quality of an image, and is a problem caused by the finite size of the source. Therefore, with a very small size source, the penumbra effect can be reduced or even eliminated. By electrostatically focusing the electrons bombarding the target on an x-ray tube of a focal spot size of a few micrometers, it is possible to produce a very small (mircofocal) source. However, because of the cooling limitations of such a small target, the intensity of microfocus x-ray tubes is quite low [7, 135]. With such a source, it is possible to detect small flaws by placing the examined object close to the source and positioning the recording device (film or fluorescent screen) at some distance from the object. This is because as Eq. (6.11) shows, for a very small focal spot size, one can afford to increase the film-to-object distance, L, and decrease the source-to-object without significantly increasing the geometric unsharpness distance, of the image. A decreased value of reduces the amount of divergence of the source photons, making the source appear to the image as a more confined beam, so that the source covers an area on the surface of the object that is not different in size from the size of the source itself. The detectability of small flaws is further enhanced by increasing the
Imaging
613
value of L, allowing in effect a geometric magnification of the object as it is projected on the receiving film, or screen, over a wider area. This magnification process, known as projective or shadow radiography, virtually eliminates any image blurring that may be caused by radiation, as the scattering photons are unlikely to reach the recording medium, at least in an area surrounding the projected image, due to the large distance between the object and the recoding medium. These factors combined, enables microfocus radiography to detect flaws of a size about equal to that of the source [4], which makes it possible to examine flaws in the range, found in brittle materials, such as ceramics. In addition to the use of microfocal radiography in detecting flaws in ceramics [850, 851], the method has been used to analyze the failure of heat-coupled thermionic (rhenium and a molybdenum-rhenium) energy converters [852]. The technique was also utilized in the characterization of silicon-carbide specimens, and proved useful in detecting high-density inclusions and isolated voids [853]. Welded repairs on turbine blade tips were also monitored with microfocus x-rays [7]. The welding parameters of small tube-to-tubesheet welds of a steam generator were also evaluated and optimized using microfocal radiography [854]. Microradiography was also used for detection corrosion, such as for the characterization of corrosion pitting in 2024-T3 aluminum alloy [855]. The technique was applied as well to image the thickness variation of electrically deposited Cu-composite coatings placed on a rotating desk electrode [856]. The same reference reported the use of this technique to image archeological pieces found in a Roman villa. Real-time microfocus radiography was used, with the help of a digital image processing system, to determine how discontinuities are created during light-metal casting, following the entire casting process from the filling of the mould until the completion of solidification [857]. The produced images were used for determining changes in metal density, to identify the solidification phase, and to observe the creation and propagation of discontinuities in the sequence of stored images. Microfocus radioscopy was also employed to detect very small defects in ceramic products with high speed and reliability [858]; and for the internal inspection of critical electronic assemblies such as potted modules, populated printed wire boards and ‘black boxes’ with an ultra small focal spot size [859].
13.1.5.
Megavoltage Radiography
For imaging objects of large areal densities (mass density × thickness), it may be necessary to employ high-energy x-rays produced by linear accelerators, typically in the energy range of 4 to 8 MeV [7, 135],
614
Radiation Probing, Gauging, Imaging and Analysis
but higher-energy sources have been used. Most reported applications of megavoltage radiography is in medical imaging during radiotherapy (portal imaging), to take advantage of the high photon-energy used in cancer treatment, see for example reference [860]. However, 1 to 3 MV x-rays are useful for imaging steel thickness from 50 to 200 mm, while 3 to 8 MeV x-rays can be used for radiographing up to 0.3 m of steel [7]. Radiography of cargo containers and vehicles was also performed with the aid of a high-energy linear accelerator similar to that used in radiotherapy [861, 862, 863]. This system is a direct descendant of a rocket container x-ray inspection system, developed to support on-site verification measures included in the arms control agreement with the former system was also developed for Soviet Union. An isotope-based radiography of vehicle and cargo [864]. The 6.13 and 7.12 MeV gammarays emitted from the decay of were also proposed for use in radiography [865]. Such a source can be transported in a small pipe (after irradiating the parent material of or see section 2.2.4) and used to image objects that are difficult to access using other sources [665].
13.1.6.
Low-Energy Radiography
While the radiography of large and dense objects requires the use of megavolt photons, as discussed in section 13.1.5, imaging of thin and lowdensity materials requires photons of low-energy. With x-ray tubes, the maximum energy of emission is controlled, as discussed in section 2.2.1 by the applied voltage, which can be readily reduced to as low as needed. However, to enable low-energy photons, below about 40 keV, to leave the tube housing, the tube must be equipped with a thin widow of a light material. Typically beryllium windows less than a mm thick or a polyester film are used for this purpose [7, 135]. An interesting way to producing the intense low-energy x-rays that can be used in flash radiography (see section 13.1.3) is by the use a high-power laser pulse focused on the surface of a solid. This results in the creation of high-temperature plasma that emits an intense pulse of photons in the extreme ultra-violet (EUV) and the soft x-ray (XUV) regions of the electromagnetic spectrum. The technique employing such a laser source is called laser radiography. These intense sources are useful for flash radiography [866], to resolve small structures such as an imprint on a thin foil [867, 868]. Low-energy x-rays are also useful in performing microradiography. Notice that microradiography differs from microfocus radiography, discussed in section 13.1.4, in the fact that the former does not need a microfocused beam as it employs a regular x-ray beam. However, microscopic details (void, discontinuities, and material constituents) can
Imaging
615
be observed in microradiography as it images thin sections using very slow (fine grains) films placed closely below imaged sections (preferably enclosed in a vacuum cassette) [134]. The developed film is then viewed via optical magnification by a factor of 50 or more. The use of low-energy photons facilities the imaging of such thin sections. Low-energy photons have a high photoelectric cross-section, which enables good absorption within a thin object, and a high material-contrast due to the strong dependence of the cross-section on the atomic-number, see section 3.4. Microradiography is used to inspect metallurgical sections for corrosion, pitting and damage [869, 870, 871]. Example applications of microradiography to polymers include: examining the dispersion of pigment in polyethylene [872], and of magnetic-oxide in polymer matrix, and for imaging the fiber orientation distributions of resin samples filled with short glass fibers at various strains [873]. The technique has been also used to study cemented joints in corrugated cardboard, to distinguish between natural and cultured pearls, and to image the distribution of inorganic spray materials on foils [134].
13.1.7.
Bremsstrahlung Radiography
An interesting emission method of imaging was proposed in reference [874, 875], where the bremsstrahlung (x-ray) radiation associated with the transport of beta-particles within matter is used to reconstruct an image of the beta-source. For a beta-source such as the maximum range in water is about 7 mm, but most of the particles are stopped in the fist few millimeters (see section 3.3.2). Consequently most of the bremsstrahlung radiation is produced in the proximity of the source where the intensity and energy of beta-particles are still high. Therefore, the intensity of the emitted bremsstrahlung radiation is indicative of the position of the beta-source. An image of the distribution of the beta-source within the object can be obtained. However, the energy of the emitted x-rays peaks at an energy of about 30 keV, limiting penetrability of the emitted radiation. This method, theretofore, can be used to image low-density materials, such as plastics and organic materials.
13.1.8.
Laminography
Laminography, as the name indicates, is the process of imaging thin layers within a object. However, unlike computed tomography, discussed in section 6.4, the image is not reconstructed to obtain pixel-by-pixel information. The radiographed layer is virtually defined by moving the source and the film synchronously in opposite directions, as schematically shown in Figure 13.1. The intersections of the radiation projections
616
Radiation Probing, Gauging, Imaging and Analysis
will have in common one plane, called the focal plane. Points on the focal plane will always be projected at the same locations on the film, and hence will be imaged sharply. All other points of the plane will be projected at varying locations on the film, providing a superimposed background image, around the image of the focal plane. The location of the focal plane is determined by the relative positioning of the source, object and film. By moving one of them, a new focal plane can be imaged. The laminographs of many adjacent slices provides a three-dimensional image [876]. Along with a microfocused x-ray source, laminography can provide layer-by-layer radiographs in “slices” a few micrometers in thickness. Therefore, laminography is useful for imaging thin multilayered struc-
Imaging
617
tures, such as ball grid arrays [877, 878] and printed circuit boards. In fact, most of the reported applications of laminography are in the manufacturing of microelectronic circuit boards. The technique is used for the detection of soldering anomalies (such as voids, disbonds and insufficient solder) that are difficult to find or are hidden on the newer packaging interconnect technologies, see for example references [879], [880] and [881]. X-ray laminography inspection is, therefore, an effective tool for screening defects in complex printed circuit boards before their functional testing [882].
13.1.9.
Scatterography
Although scatter imaging is not as widely used as the conventional transmission-based imaging techniques, scatter imaging, or scatterography, offers some advantages, as discussed in section 7.6. Unlike transmission imaging, which requires the source and the detector (or image receptor) to be placed at two opposite sides of the object aligned with respect to each other,scatterography allows placing the source and the detector on the same side. This permits same-side imaging, a useful feature when imaging extended or thick structures. While transmission provides an integrated indication along the path of the incident radiation, see for example Eq. (6.1), scattering can provide point-wise indications, i.e. an indication at the point of scattering. The scattering process is, however, a complex one, since scattering events can overlap each other making it difficult to extract a meaningful image without mathematical unfolding of the measurements, as discussed in section 7.7. However, superficial and near-surface images, and images of light materials can be obtained with direct recording of scattered radiation, as exemplified by the applications presented below. An x-ray backscattering device, called the Comscan [883, 884], is employed in a number of applications. This system uses an array of detectors, with each detector’s field-of-view defining a small voxel on the surface of the object upon intersection with an incident x-ray beam. The intensity of the scattered radiation forms the image, with higher intensity indicating higher material-density and vice versa. This imaging approach was also applied to the imaging of: plastics [885]; castings; aircraft- and automobile structures [886]; an aluminum cast car wheel and an aluminum weld [887]; a glass-reinforced plastic/foam sandwich material [888, 889]; carbon-fiber-reinforced plastics [884]; a plaster painting (fresco); a mummified body, and a medieval bronze clasp [890]. Comscan was also used for the detection of second-layer and metal loss in aircraft structures [891, 884], and for the under-water inspection of sonar domes [892, 893, 894, 895].
618
Radiation Probing, Gauging, Imaging and Analysis
Another Compton-scatter imaging system, called AIDES (Automated Inspection Device for Explosive Charges in Shells) was used as the name applies for imaging shells to detect porosity [896, 897]. The system employed a collimated bremsstrahlung beam (using a 5.6 MeV linear electron accelerator), and six collimated detectors for point-by-point imaging of the shell. Scatter imaging can also be used in real time-imaging. For this purpose, a system was designed employing a 100 to 200 kV x-ray tube and scintillation plates and two image intensifies, along with a charge-coupled device ( CCD ) camera as the readout device [898]. A low-energy/low-dose x-ray backscatter system is available for personnel imaging for detecting materials concealed under clothing [899]. The use of scattering necessitates the scanning of one side at a time (front and back). Isotope-based systems are also used in scatterography. A was designed for void detection in light alloys and plastics [308]. The same reference also mentioned the use of the technique to produce images of aluminum castings, used in the automobile industry, to detect voids of about 2 mm in diameter. Another radioisotope-based Compton scatter system, using a weak source, was also proposed, for detecting voids in sections of steel, polyethylene and an inorganic ceramic cement [900, 901]. The combination of scattering and transmission imaging was considered for imaging vehicles and large cargo containers, with a pair of 450 kV x-ray sources and their corresponding detectors to give two transmission images and two scatter images of the inspected vehicle during a single scan by sweeping (fly-spot) the x-ray beams along the object [902, 903, 904, 905]. The above scatter radiographic methods rely on imaging voxels defined by the intersection of the confined fields-of-view of the source and the detector. Thus, image information is derived directly from the incident radiation beam, after the photons scatter, within the voxel, towards the detector. This imaging approach is in essence based on single scattering. Proper confinement (collimation) of the source and the detector fields-of-view is, therefore, essential in these systems. The two fields-ofview must also intersect to form the imaging voxel. This intersection requires proper alignment of the source, object and detector. Although this alignment process can be cumbersome, it enables three-dimensional imaging, since the voxel(s) can be located anywhere in the space, by proper positioning of the source and the detector. There is, however, a class of imaging systems that are less vulnerable to these alignment process, as they rely on imaging photons that migrated away from the
Imaging
619
source. These migrated photons form a “cloud” of radiation from which photons scatter to detectors. If the distribution of this cloud is disrupted by the presence of abnormalities, the response of the detectors monitoring this cloud will be altered accordingly. One version of this imaging process is the lateral migration radiography system designed for landmine detection [906, 907, 908, 909]. In this system, a collimated beam of x-rays is directed towards the ground and a set of collimated and uncollimated detectors are used to monitor photons that are laterally migrated away from the source beam. The wide field-of-view of the uncollimated detectors makes their response dominated by the flux of highest strength, which is that of photons near the surface. On the other hand, with the collimated detectors, the effect of photons scattered from the ground surface is less dominant, thus they are sensitive to photons emerging from both the surface and depth of the ground. The images produced by these detectors are in effect contours of the detector counts, from which the presence of an anomaly can be identified. Another approach of scatter imaging that relies on mapping photons scattered over a wide volume, with the aid of open (unconfined) detectors, was proposed for imaging pipe walls for the detection of wall thinning (due to corrosion) [910, 911, 912]. The system uses a collimated source with two detectors placed at equal distance but at opposite sides of the source, with the source-detector assembly mounted on the pipe walls and rotated around the surface of the pipe with a stepping motor to map the entire circumference of the pipe. To eliminate detectordependence on the distance from the pipe surface to the detector, the use of a dual-energy source was suggested. The scattering of low-energy photons results mainly from near the surface of the pipe walls, while the more penetrating higher-energy photons scatter from everywhere. The ratio between the counts produced by higher-energy photons to that of the lower-energy ones tended to remain constant as the distance from the detector to the pipe changed. The magnitude of the ratio was shown to be indicative of the pipe wall thickness. Therefore, the contours of this ratio, obtained as the device scans the pipe, provides indications of changes in pipe thickness.
13.1.10.
Emission Imaging
Emissions can arise from a radiotracer injected into the medium, radioactive materials that is already present, or from reactions induced by an external source. Emissions in the form of photons can be readily imaged with a gamma-camera, see sections 4.3.2 and 8.8.4. Flow visualization with radiotracers often employs a gamma camera. For example, a scintillation gamma-camera was used for imaging the movement of
620
Radiation Probing, Gauging, Imaging and Analysis
radiotracers for velocity, trajectory and particle density measurements, in fluidized beds [913, 914] and chemical reactors [915]. Gas-flow inside a fluidization test bed was visualized with the aid of a gamma-camera (190 keV energy, 13 s half-life) observing the emissions from a source [916]. Also, fluid displacement in thin slabs of porous media were source as a tracer observed with a gamma-camera with the help of a in the water phase [917]. Using the same method, the flow of an oxygen and oil (labeled with 140 keV, 6 hour) gas (labeled with was imaged to study the degasification process of a gas merged with a feed stream of heavy oil, by spiking each phase separately with the gamma emitter [916]. Images of the flow of bulk solids (silica spheres) (392 keV, in a storage bunker were obtained by immobilizing 1.658 hour half-life) on some spheres [916]. The location, distribution, and intensity of gamma-ray emitting sources in nuclear sites can also be surveyed with the aid of a gammacamera, see for example references [918], [919], [920], and [921]. The Compton-scatter camera, as discussed in section 8.8.4, offers the ability to provide images at arbitrary image planes. By reconstructing images with such camera at different planes, the location of high intensity ‘hot spots’ can be determined. Therefore, the Compton-scatter camera has found applications in nuclear waste to identify hot spots in mixed waste, image large objects or contaminated areas, and for monitoring production, deployment, shipping and storage of nuclear warheads and components [922, 923]; as well as for imaging radioactive areas in a nuclear fuel reprocessing plant [923, 924]. The indirect imaging technique of coded-aperture, commonly used in astrophysics imaging, is employed to image weak sources of radiation, by blocking the emitted radiation with a mask containing holes of a certain pattern. Radiation emitted from various points in the object that passes the coded-aperture mask, and detected on a scintillation screen, produce a pattern that can be deconvoluted to produce an image of the source intensity and location. Positron emission induced by the pair-production reaction of highenergy photons is also proposed for elemental imaging, see section 12.2.2.7. Reference [925] reported the use of positron emission for imaging oil flow on surfaces. The flow of oil down two planes of different inclinations in a simple aluminum and Perspex tower, in a static journal bearing and on lubricating-oil bearing race, was imaged by labeling the oil with a positron emitter (1.13 hour, half-life) produced from the decay of (270.8 days, half-life).
Imaging
13.1.11.
621
Diffraction Imaging
Patterns produced by x-ray diffraction, discussed in section 7.8.1, can also be recorded on a film. A number of arrangements can be used [134]. The basic Bragg arrangement involves the use of a monoenergetic narrow beam of x-rays and rotating the material specimen until a distinct refraction pattern is recorded. The lattice spacing can then be calculated from this pattern using Bragg’s law, Eq. (3.66). When a multienergetic beam is used (Laue’s method), the examined object stays stationary and dense spots appear corresponding to the planes in the crystal where Bragg’s law is satisfied at the various source energies. Both above arrangements are suited for examining single crystals. The Debye-Scherrer-Hull method overcomes this problem by using a powdered form of a polycrystalline material; hence the name powder method. The powder sample is enclosed in a fine glass capillary or suspended on a fiber or a flat ribbon of a low-density material [134]. The powdered sample offers many random lattice planes that can diffract an incident monoenergetic x-ray beam, producing many pattern fringes from which lattice information can be deduced. In the forward-scattering arrangement, typically used to examine thin samples, a small lead block is placed on the film to prevent the incident beam from fogging the film [134]. To examine the surface of a material, a backscattering modality is utilized. An alternative to film radiography is the use of a microchannel to measure radiation diffracted towards a particular direction. The parallel channel of the plate acts as collimator tubes that limits the detected radiation to that diffracted from a particular region in the medium. A wide x-ray beam can then be used to provide wide-area imaging [926, 927]. The applications of x-ray diffraction are too enormous to individually list here, but the reader can consult references such as [65] and [235].
13.2.
Neutron Radiography
Neutron radiographs are recorded using converter screens, see section 4.4.3.2, which generate beta or gamma radiation that can be recorded on a film. For thermal neutrons, foils of gadolinrhodium ium indium cadmium and silver have been used as converter screens, using the reactions given in the square brackets. These reactions enable direct recording of neutron exposure into a conventional radiographic film [134, 928]. Scintillation screens (zinc sulfide) containing boron are also used, with the alphaand lithium particles of the reaction producing light in the scintillator that can be
622
Radiation Probing, Gauging, Imaging and Analysis
registered on a photographic film, or used to provide a real-time image with the aid of an image intensifier [928]. Light-emitting screens, combined with a large-aperture lens such as those based on system and accompanied with charge-coupled devices (CCD’s), are capable of detecting single neutron events, and thus are employable with low-intensity sources [929, 930]. The use of large amorphous-silicon sensors, instead of the CCD’s, can also provide a high light-coupling between the scintillation screen and the sensor, and eliminate the need for a lens system. For indirect exposure, using the so-called “transfer” method, converter screens made of gold 2.695 days], indium 54.2 minutes] or dysprosium 2.33 hours] are exposed to neutrons, and after the exposure is terminated the screens are removed and brought into contact with a radiographic film [134, 928]. The relatively long half-life of the reaction products, given in the square brackets, makes these isotopes particularly useful for the indirect neutron-radiography methods. Neutron radiography is advantages in two types of applications. First in imaging light materials, where the electron-density is too low to affect photons, particularly when the light material is masked by a more dense material. Secondly, in imaging materials emitting gamma-rays, such as irradiated nuclear fuel elements [931, 932], that produces interference with the photons of x- or gamma-ray radiography. The fissile material remaining in spent nuclear fuel, as well as the fission products, are also good absorbers of neutrons, while the conversion plates, see section 4.4.3.2, used to record the neutron image, are not sensitive to photons. Neutron radiography requires, however, access to a nuclear reactor or large neutron sources; although efforts are made to produce low-flux and mobile systems [933, 934, 935, 936, 937, 938, 939, 940, 941]. Isotope-based real-time neutron-radiography systems are also available, see for example reference [942] which a system. Neutron radiography is a well-established method to the extent that standards of applications are available [943, 944, 945]. Some representative applications are given here. Hydrogen. A unique ability of neutron radiography, and thus one of its main applications, is the detection of hydrogen. For example, neutron radiography was used to visualize small amounts of hydrogen in hydrogen storage alloys, such as [946]. The detection of hydrogen in metal is of particular relevance because of the brittle effect it introduces. Corrosion products are usually hydroxides, thus neutron radiography is more suited for detecting corrosion than other NDE methods that typically detect corrosion by metal loss [928], which occurs only when a
Imaging
623
significant amount of corrosion has taken place. Radiography is helpful in this regard, and was used to detect hydrogen in zirconium alloys utilized in nuclear reactors [947], and hydrogen diffusion in a palladium metal [948] and in a titanium aluminide alloy [949]. Neutron radiography is also more suited for composite materials than photon radiography, due to the low density of the composites. Therefore, neutron radiography can be used to detect voids inclusions and transverse cracks [950] and to determine the resin content of a composite [951]. It is also suited for imaging composite joints with metals, since the adhesive material tends to be more neutron absorbing than the metal [952, 953]. Neutron radiography is also used in imaging honeycomb structures, composites and adhesive layers in aircraft structures [954, 955, 956, 957]. Rubber, plastic seals and other neutron-absorber gasket material can also be examined with neutron radiography, even in metallic assemblies [928]. Epoxy-potted small electronic devices can also be imaged with neutron radiography, since the potting material is usually rich in hydrogen [928]. Neutron radiography is also used to image electrical relays employed in satellites and spacecraft [958], to disclose the presence on any undesirable hydrogenous materials such as a loose insulation [928]. Water. Hydrogen in water, as steam, moisture or two-phase flow, was also observed by neutron radiography. For example, steam generation due to direct contact of hot metal with water was visualized by neutron radiography [959, 960]. The transport processes of moisture and hydrogenous liquids in porous building materials [961, 962, 751], and other porous media [963, 964] was also studied with neutron radiography. The introduction of hydrogen-containing fluids (water or oil) into the pores of a media enables the imaging of the flow distribution in such media [965]. Scanning neutron radiography, where a single narrow beam scans across an object elevated in front of the beam, was utilized in measuring moisture concentration profiles during drying of brick and kaolin clay [966]. In situ measurement of water transport within Nafion in polymer electrolyte fuel cells was also visualized with neutrons [967]. Neutron radiography has also found use in imaging historical artifacts [928] to reveal hydrogen or moisture related details which are not observable by other means.
Flows. Another interesting application is the use of real-time radiography in the design of nozzles for subcooled hot water by imaging the water flow through the nozzle [968]. Many workers also applied neutron radiography to image the two-phase flow in metallic pipe, ducts and channels [969, 970, 971, 972, 973, 974, 975, 976, 977, 978, 979, 980, 981]. The
624
Radiation Probing, Gauging, Imaging and Analysis
flow of water in heat exchangers was also studied with neutron radiography [982, 983]. Visualization and measurement of nitrogen gas-molten lead/bismuth two-phase flow in a rectangular pool made of titanium 5 mm in thickness) were performed [984, 985], since neutrons more easily penetrate such metallic thickness than photons. Neutron radiography proved also useful in the visualization of internal flow in refrigerator components [986, 987, 988, 989, 990, 991]. The water uptake in plant roots was also studied with neutron radiography [992]. The method was also used to study fluid-rock interaction, water infiltration into a porous rock and the displacement of heavy-water by oil and water flooding of a clay-rich rock [993]. Dynamic neutron radiography was used to image the micro architecture and oil infiltration in Visingso sandstone reservoir [994]. Reference [928] reported the use of neutron radiography to study the movement of water/moisture in concrete samples with time and temperature. By observing, with dynamic neutron imaging, the falling of a spheres in a silicate melt, the viscosity and density of the melt was measured at high temperatures and moderate pressures [995]. Backscatter imaging of neutron is also employed for the detection of hydrogenous materials. Reference [996] reported the use of a neutron-sensitive imaging-plate placed close to the object to detect the neutrons scattered from quartz cells containing water; with a neutron beam extracted from a reactor. Neutron Absorbers. Materials containing highly neutron-absorbing elements are obviously natural candidates for neutron radiography. Such elements can be introduced as contrast enhancers into less neutronabsorbing materials to enable imaging of such material, as indicated by some of the examples discussed here. One of those highly neutron absorbers is which can be produced by beta-decay of and the latter can be present in the metal as result of exposure to tritium in fusion and bubbles enable the heavy-water fission reactors. The formation of investigation of tritiated metal samples with neutron radiography [997]. Lithium, another good neutron absorber, was also useful in a number of applications of neutron radiography, such as: imaging of lithium-bearing ceramics and glasses [949]; evaluating the reversibility of rechargeable commercial lithium batteries [998]; and the study of lithium-ion transfer in solid ionic conductors [999, 1000, 1001, 1002, 1003, 1004]. The high neutron absorption cross-section of gadolinium makes it an attractive image enhancer, and was used in the neutron radiography of aircraft aluminum alloys (by the application of an aqueous solution of gadolinium nitrate for the detection of corrosion [957, 1005]; the detection of residual core in the casting of air-cooled turbine blades by the addition
Imaging
625
of gadolinium compounds to the core material [1006, 1007]; and for the study of cracking in concrete [1008]. Gadolinium in the form of gadolinium chloride aerosol was used in real-time neutron radiography to observe the deposition of a neutron absorbing aerosol in a standard cellulose acetate cigarette filters [1009, 1010]. Cadmium was also used in the visualization of liquid-metal flow, by using particles made from a gold-cadmium intermetallic compound as a tracer for visualization of molten liquids [1011, 960, 1012]. Sand coated with was also used for imaging particles in a fluidized bed [1013]. Needles to say, materials containing boron are also good candidates for neutron radiography [1005]. Tracer particles made by bonded to vinyl resin were used to observe material flow in a fluidized bed [1013]. Reference [24] reported the use of neutron-radiography for the determination of rareearth elements (lanthanides) in minerals (monazite and bastnaesite) by placing thin section of the minerals in between thin plates soaked with boron and shielded from gamma-rays with lead sheets. The assembly was then exposed to thermal-neutrons and the ratio of the tracks produced in the developed film with and without the thin mineral sheets, were taken as indicative of the concentration of the neutron-absorbing lanthanides. The neutron absorption of rare-earth elements was also used to examine the ceramic in investment-cast turbine blades, made by molding metal around a ceramic core in which open cooling passages are created by leaching [928]. The injection of gadolinia into the ceramic core further enhances the image. Ceramic capacitors can also be inspected with neutron radiography [928]. The difference in the neutron absorption cross-sections of indium and gallium (with the former more than an order of magnitude larger than the latter) enables the neutron radiography of a gallium-indium alloy to measure any macro-segregation in its solidified ingots [1014]. The neutron absorption ability of uranium was also exploited in determining its concentration in Black Sea sediment samples [1015]. Neutron-absorbing materials (such as sodium-borate or gadolinium nitrate) dissolved in neutron-transparent fluids (such as heavy water and halocarbon oils) were also used to study fluid flow in porous media [965]. The same workers used a metal alloy containing cadmium to measure, with digitized neutron radiography, the porosity patterns etched during the reactive (acidation) dissolution of pores. Neutron radiography was also used to detect explosive materials, even when encased in metal. Explosives (HMX, RDX, PETN) have a total crosssection for thermal-neutrons of about 1.28 to compared to for lead. Therefore, the for stainless steel and presence of these explosives with metallic shells and casing can be easily detected. Neutron radiography was, therefore, used to inspect ammu-
626
Radiation Probing, Gauging, Imaging and Analysis
nition cartridges for the detection of ammunition filling [2, 1005, 1007], and to image explosive lines (used to separate components and eject military pilots), and explosive bolts and detonators [928]. A system was considered for imaging small quantities of metal-encased explosives [1016]. The detection of paper separation-washers and plasticcomponents of fuses was also accomplished by neutron radiography [7]. Nuclear Materials. Neutron-radiography is useful in a number of applications in the nuclear-power industry. It can be used to image fresh fuel to determine its enrichment level since is a much stronger thermal-neutrons absorber that [928], due to the fission of the former by thermal-neutrons. Irradiated fuel, in spite of its high gamma-radiation emission can be imaged with neutron radiography using the transfer method discussed at the beginning of this section. The used converter screen are only sensitive to the neutrons, attenuated by the fuel, but not to the gamma-radiation of the fission products, due to the absence of the film. The image is then transferred from the converter screen to a film, away from the fuel. The imaging of irradiated fuel enables the determination of fuel burnup, i.e. the reduction in the concentration of using the same concept discussed above for fresh
fuel. [928]. Reactor control rods, typically made of cadmium, are also imaged by neutron radiography [928].
Neutron Transparent Materials. Neutron radiography is also useful for imaging low-absorbing materials, such as aluminum, within a more neutron-absorbing medium. For example, neutron radiography was used for inspecting the space shuttle’s solid rocket booster which include aluminum components that may corrode or entrap moisture [1017]. Fast Neutrons. Most of the applications discussed above rely on the use of slow-neutrons (thermal) due to their ease of detection. However, epithermal and fast neutrons are also used in radiography. The so-called transfer technique is often employed, where activation foils are used as the recording medium and the intensity of the gamma-ray produced from the activation process is later recorded on a photosensitive film or a gamma-sensitive scintillation screen [1018]. However, directimaging methods are emerging. For example, the tracks produced on plastic sheets (CR39) were used to image neutrons of energy between 0.1 and 10 MeV [1019]. References [1019] and [1020] reported the use of a converter screen made of polypropylene and ZnS(Ag), in which fastneutrons collide with the hydrogen of the material producing recoiled protons that in turn give rise to luminescence in ZnS(Ag), and the emit-
Imaging
627
ted light can either be recorded on a film or displayed on a television screen. Radiographic images of fast-neutrons can be obtained by measuring the energy of neutrons emitted from a pulsed-source using the time-of-flight method (see section 4.26). The radiograph is then reconstructed from the detected neutron intensity at the source energy. The advantage of this method of measurement is that it eliminates the effect of scattered radiation, and the interference of gamma-rays, by utilizing only uncollided neutrons (i.e. those with the same energy as the source) in formulating the image [1021]. The penetrability of fast-neutrons makes it possible to image light objects enclosed in dense material, such as void in uranium and air-oil two-phase flow in a thick iron block [1019] and in air-water two-phase flow in a 4 × 4 rod-bundle near a spacer [1022]. Reference [1023] also presented a method for imaging neutron sources within a nuclear missile that relies on the use of a neutron camera (similar to that of the Compton camera described in section 8.8.4). The neutron camera monitors the double-scattering of a neutron with the elements of two consecutive arrays of organic-scintillator, and the direction of the incident neutron direction vector is reconstructed from the provided information. Fastneutrons were also used for radiographing thick laminated composite materials [1024]. Very high-energy neutrons (from spallation sources) were also studied for future use in radiography, due to their high penetrability and the direct proportionality of their cross-section to where A is the mass-number [1025]. The latter feature makes it possible to better distinguish light and heavy elements with neutron radiography, in comparison to photon radiography where the contribution of light elements is much weaker than that of heavy elements. To detect fast-neutrons, reference [1025] suggested the use of a converter screen (tungsten or copper plates) that produce protons when bombarded by neutrons. The position of the proton, hence the neutron on the screen, can be determined by a two adjacent multiwire detectors, or by the localized measurement of the electron avalanche produced by the protons on the converter plate [1026]. Alternatively, a matrix of scintillating optical fibers can be employed. Fast-neutron radiography was also used for testing components of space launch vehicles, using a small proton cyclotron and a beryllium target [1027]. Inclusions in Iron. Imaging non-ferrous material present in iron can be performed by iron-filtered neutrons [1028]. Iron has several minima in its total cross-section, at energies in the keV range, specifically, 24, 78 and 134 keV, allowing neutrons at this energy range to pass through reasonably large thickness (up to 200 mm) of iron. Other inclusions in iron,
628
Radiation Probing, Gauging, Imaging and Analysis
such as a Al, Cu, or Pb, will tend to attenuate the neutrons more within these energies, and will accordingly leave a noticeable change in the recorded signal. However, to detect neutrons at these specific energies, neutron spectrometry must be performed. Reference [1028] reported the use of a pulsed photoneutron source (accelerator) that employed 30 MeV electrons on a water-cooled tantalum target. The neutrons were moderated with polyethylene, filtered with two Fe layers (140 mm and 100 mm in thickness) and collimated with borated paraffin and lead collimator. Time-of-flight measurements, see section 4.25, were then used to detect scintillating detector. From the recorded the neutron energy with a neutron intensity at the iron filter energies, at different locations across the objet, radiographs or even tomographs of the object can be constructed. Neutron Diffraction. Recorded neutron-diffraction patterns, see section 3.5.5.1, are a from of radiography. For example, neutron imaging was employed to examine bulk polycrystalline materials, such as the Alnico iron alloys used industrial permanent magnets [1029]. The diffracted cold neutrons were recorded on a scintillator equipped with a lead-glass microchannel plate, placed between the sample and the detector. The microchannel acted as a tube-like collimator to prevent crossover of neutrons diffracted from various locations.
13.3.
Charged-Particle Radiography
Beta Radiography. Beta-particles, though not very penetrating, are useful for imaging thin layers, such as paper sheets [1030, 1031] or oil and were utilized paintings [238]. Low-energy beta-sources, for radiography of forensic documents [1032]. The surface of thicker objects can also be photographed by capturing backscattered beta-particles foil), this method was on a film. With an extended beta-source used to radiograph the surface of a sandstone rock sample containing uraninite, to identify uranium bearing phases [1033].
Electron Radiography. Electrons can be used for imaging in two modalities: transmission (see section 6.6.3) and emission (discussed in section 8.5.1). In the transmission modality, the electrons are generated in a foil of a high atomic-number material (typically lead) by bombardment with x-rays. The generated electrons are transmitted through a thin sheet of material and recorded on a film underneath the sheet to obtain an image of the distribution of its material. This process is, therefore, analogous to that of beta-radiography discussed above, except that
Imaging
629
the use of x-rays allows the generation of a high intensity electron field. To avoid the simultaneous generation of an x-ray image, high-energy photons are employed; a 300 to 400 kV machine with a heavy filter (typically copper) to remove lower energy photons. This methods was used to image papers for watermarks, fiber distribution and ink overprint, and to authenticate rare postage stamps [7]. The technique is also applied to the imaging of wood shavings, leaves, and thin sheets of rubber and plastic [134]. The other modality of electron emission is used to image the surfaces of thick metallic objects. As discussed in section 8.5.1, electrons on the surface of the inspected object are generated with x-rays and the emitted electrons are recorded on a film placed on top of the surface. The source x-rays are filtered to eliminate the low-energy photons that can produce an x-ray image on the film. Electron emission imaging was performed, under low vacuum conditions, on polished sections of a steel-concrete interface to examine whether the formation of any of the hydration products of cement is favored at this location [1034]. The technique was also used to study the dissolution of dental enamel [1035]. Metallic pigment in printed paper (a stamp) was also detected using this method [134]. Proton Radiography. Protons offer the ability to measure small thickness changes, since unlike photons and neutrons, they are easily attenuated by matter. Proton radiography was used to study of the temporal and spatial behavior of shock propagation in a high explosive sample using 800 MeV protons [1036]. Radiography with protons was also considered as a means for examining the safety and reliability of nuclear weapons stockpiles [1037, 1038]. A 800-MeV proton radiography facility has been developed for imaging dynamic objects, such as the evolution of a high explosive burn [1039]. The scattering of 500-1000 MeV protons was also considered for three-dimensional reconstruction of an object with only one exposure, by tracking the passage of the incident scattered beams [1040]. Protons in the GeV energy range can interact with the nucleons (protons and neutrons) of the nucleus in a “quasielastic” fashion that has the characteristic of collision between two particles of identical mass. These collisions result in angular-deviation of the protons. The trajectory of the incident beam and protons scattered in the forward direction can be recorded on a scintillation screen, and used to compute the three-dimensional coordinates of the interaction vertices. The intensity of the interaction vertices reflect the density of the material scattering the protons. This method was used to radiograph
630
Radiation Probing, Gauging, Imaging and Analysis
an electric motor [1041], and to detect defects in 50-mm thick copper and uranium pieces and a liquid hydrogen target [1042]. Ionoluminescence Imaging. The visible light emitted from a material subjected to MeV ions, called ionoluminescence, can produce information on the chemical bonds, energy band structure in semiconductors and impurities and defect distributions in crystals. Proton-beam (2.5 MeV) luminescence was used to image the grains of a zircon mineral and a thin membrane of organic material (Kimfol) [1043].
13.3.1.
Autoradiography
The term “autoradiography” indicates to a “self-induced” image, in the same way “autography” refers to a person’s own handwriting. Autoradiography is, therefore, the imaging of a material emitting radiation. It is thus a from of emission imaging (see section 8.8.3). The radioactive material producing the radiation emission can be introduced in a number of ways as the applications discussed in this section demonstrate. The technique is usually applied to charged-particle emission to provide superficial (surface) images, due to the short range of charged-particles; although imaging of gamma-ray emission is also possible as discussed in section 8.8.4. Natural Radioactivity. Autoradiography lends itself to the imaging of materials containing natural radioactivity. Therefore, the method is (a beta useful for determining the U and Th (alpha emitters) and emitter) content in rocks [1044]. Nuclear emulsions, see section 4.2.1, are typically used for detecting these particles, as they contain a higher concentration of finely grained silver halide than photographic emulsions. The number of tracks left on an emulsion plate is directly proportional to the concentration of the emitting material in the monitored medium (mainly the surface of the medium due to the short range of alpha and beta particles). Since both U and Th are alpha emitters, the recorded images reflect their total concentration, but empirical relationships can be used to determine their relative concentration [1044]. Nuclear Fuel. Nuclear fuel elements can be autoradiographed to determine the fuel distribution and cladding (metal sheath) uniformity in fresh and the fission-product in spent (irradiated) fuel [134]. Fresh fuel emits radiation by the decay and spontaneous fission of its fuel, while spent fuel emits radiation by the decay of its fission products. The radiation emitted is recorded on a film to assess various properties of the fuel elements. When the fuel is uncladed (no metal sheath), or when
Imaging
631
the cladding is uniform, the distribution the film density can be related to the fuel content in the element, see for example reference [1045]. On the other hand, for a uniformly loaded fuel, the film density becomes an indicator of the cladding thickness, and fuel-pellet welds and end plugs [1046]. For spent fuel, a slow (large grain) film is used because of the high intensity of the emitted radiation. The image obtained on the film will then reflect the concentration of the radioactive fission products. Selective autoradiography is also used to distinguish between mixed nuclear fuel uranium and thorium in uraniathoria pellets, by taking advantage of the difference in alpha-particle energy of the daughters of uranium and thorium [1047]. A special film with annealing and pre-etching treatment was used to obtain sufficient track density from the very low specific activity of natural uranium and thorium, and to enable distinguishing between their tracks. The distribution of plutonium on the surface of a pellet, after diffusion annealing, was also obtained by alpha-autoradiography [1048]. Alpha-autoradiography was also utilized to determine the concentration of transuranium nuclides in the primary coolant of a nuclear power plant deposited on filters [1049]. Void that may be present in containers used to store spent fuel can also be detected with autoradiography [1050]. Tritium. In studying metal hydride formation, caused by migration of hydrogen into metal grain boundaries or other discontinues, (a beta emitter) can be used as a substitute for hydrogen, and the autoradiographs of the hydrogen distribution can be monitored by placing a radiographic film next to the specimen [238]. This process was used recently to study the distribution of hydrogen in Ni-based super alloys [1051]. The autoradiography of was also used for studying the effectiveness of a detritiation (tritium removal) process of steel activated in a nuclear fusion facility before disposal as a nuclear waste [1052]. Similarily, the distribution of hydrogen in intermetallic compounds [1053] and in a (Zr, Ti, Ni) alloy [1054], was investigated by means of tritium autoradiography.
Sulfur. Another useful isotope for autographic imaging is (a beta emitter, 87.32 day half-life) which when introduced in welding as a base material, or into the electrode of the welding torch, can be used to visualize how sulphur is distributed into a weld, and from where the sulphur content originates [179]. The same isotope can be introduced into molten steel for later study of the material homogenization by autographing slices of the solidified ingot [7]. The isotope (a beta emitter, 14.262 day half-life) was also used in the autoradiography of
632
Radiation Probing, Gauging, Imaging and Analysis
the leaching of phosphate in structured clay soil [1055]. The positrons emitted from (a positron emitter, 2.6019 y half-life) was used in the study of the diffusion behavior of sodium in poly (ethylene oxide)-poly (vinyl acetate) films [1056]. Activation. The examined object may also be activated in a reactor or by an accelerator. For instance, to study the material transfer from a projectile to the barrel of a rifle, the plating of bullets were irradiated in a reactor to produce (a positron and a beta emitter, 12.700 h half-life) and after shooting the rifle, the distribution of the active material in the inside of the pipe was autoradiographed (after cutting the pipe along its axis) [179]. More recently, the distribution images of C and O in steels and B and O in Al alloys was studied by charged-particle activation-autoradiography, after irradiating the samples with ions (a positron emitter with generated in a cyclotron [1057]; producing a 20.39 min half-life) from B, or C and (a positron emitter with a 109.77 minute half-life) from O. Neutron-induced autoradiography was also applied for measurement of Li-concentration profile in Al-3.5Li and Fe-4.34Ni alloys during solidification [1058]. The distribution of boron implanted into silicon [1059] and in boronized specimens of steel [1060] was also studied with neutron autoradiography. Another application of autoradiography is in determining the efficiency of a polymer chipblender by labeling the chips with a chemical tracer (indium) and irradiating the samples in a nuclear reactor to produce a beta emitter (1.0 MeV maximum energy, 54 min half-life) [1]. The irradiated samples were then autoradiographed on a film and the results analyzed to determine the blending efficiency. Neutron-induced autoradiography also enabled the measurement of the concentration of uranium and boron in some minerals (lorandite, realgar, stibnite, orpiment and dolomite), making use of the tracks produced by the (n,fission) reaction products and the reaction [1061]. Mineral samples were placed in contact with an etched-track detector foils (for uranium detection) and a phosphate-glass etched-track detector (for boron detection) and irradiated in a reactor. Neutron-activation autoradiography was also used for the imaging of paintings [1062, 1063].
Iron. Labeled isotopes, such as (a beta emitter, 44.472 day halflife), can be used to study the distribution of iron in a medium, e.g. iron in magnetic recording tapes or iron ions in the residue of an etching solution [179]. The transport of oxygen in scales growing on nickel atmosphere, was studied by labeling the material and cobalt, in a
Imaging
633
with and subsequently autoradiographing it using the nuclear reaction [1064]. Environmental. Autoradiography has also been useful in environmental studies. For example, the accumulation of waterborne mercury in fish and snow crab brain was studied by injecting the fish with (a beta emitter, 46.612 d half-life) and performing a whole-body autoradiography [1065, 1066]. Autoradiography was also helpful in the identification and analysis of a radioactive particle in a marine sediment sample [1067]. The penetration depth of radiological contamination through the thickness of transite (an asbestos-cement building material) was also investigated by progressively removing layers of material and subsequent autoradiography of the exposed surfaces [1068]. Real Time. One recent attempt to produce real-time digital autoradiographs includes the use of a field-effect transistor integrated on highresistivity silicon (depfet), in the form of a panel of many depfet pixel detectors, as an image receiptor, called a bioscope [1069]. This transistor is attractive for use in real-time autoradiography because of its very low noise at room temperature, its information storage capability and its thin and homogeneous entrance window. This device was used for imaging beta-emissions from a source [1070].
13.4. Tomography 13.4.1. Photon Tomography Although x-ray computed tomography (CT), described in section 6.4, is widely used in medical imaging of the human body, the demands of CT in industrial applications are quite different. In industrial imaging, a wide range of shapes, sizes and densities are encountered and the required spatial-resolution can vary from a few micrometers to centimeters. On the other hand, unlike medical imaging, in industrial radiography the radiation dose delivered to the object is usually of no concern, and object-movement (by patient breathing and nervousness in medical imaging) does not present a problem. Hence, a longer time can be used to acquire the image in industrial radiography. There is also priori information on the nature of the object that can be taken into consideration in reconstructing the image. Therefore, effort has been devoted to developing CT systems especially suited for industrial applications [1071, 1072]. For example, a system was developed specifically for improved tomography of a rocket motor by concentrating the measurements, computations, and radial-resolution at the periphery of the
634
Radiation Probing, Gauging, Imaging and Analysis
test specimen [1073]. Effort was also made to construct tomographic images from the digitization of radiographic images, particularly those obtained with fine resolution using microfocused x-rays [1074, 1075, 1076]. Gamma-ray tomography, which is not used in medical applications due to radiation dose constraints, is employed in industrial radiography, as it provides higher penetrability, see for example reference [1077]. For example, a fourth-generation (see section 6.7), gamma-ray system was used by the steel industry for process control of product (I-beam) manufacturing [1078]. CT can be viewed as a sophisticated nondestructive method for examining the internal details of industrial objects. Tomography is a NDE method with its own standards and guides [1079, 1080, 1081, 1082, 1083, 1084]. Tomography can be used to measure the dimensions of industrial parts, determine their density distribution and detect flaws, find their location and characterize their shape, size and composition [1085]. The collection of many adjacent tomographs (image slices), enables the formation of three-dimensional images. Some of the applications of photon (x- and gamma-rays) computed tomography are given here.
Flaws. A typical NDE application of CT would be in determining the internal location of flaws and discontinuity that are difficult to discern with other methods. Therefore, CT was used for detecting and quantifying the presence and extent of intergranular stress corrosion cracking (IGSCC) in pipe specimens [1086]. Tomography with or sources was also applied to the detection of small cracks caused by hydrogen ingress into carbon steel samples [1087]. CT was also applied to the inspection of bridge weldments [1088]. X-ray tomography was also employed to locate voids inside of injection molded parts [1089]. Ceramics. X-ray-computed tomography is useful in examining ceramic materials. It was used for the localization and the quantitative determination of density differences in dry-pressed alumina compacts [1090]. The determination of the density gradients in slip cast ceramics with CT was correlated with stress distribution in slip casting1 [1091]. CT was also used to quantify internal flaws in a ceramic body [1092]. With microfocused x-rays, x-ray microtomography were performed to detect small flaws on ceramic and metal matrix composites [1093].
1 A slip cast is a porous mold shaped in the negative image of the desired component and filled with a slip consisting of a suspension of fine ceramic particles, which after drying forms the solid component
Imaging
635
Composites. Computed tomography is quite useful in inspecting composite materials, since conventional radiography does not enable separation of indications from overlaying layers. For example, x-ray CT was used in the study of moisture transfer in composite materials [1094]. Xray computed tomography was also used to examine inshore mine-hunter hull composite material [1095], and to inspect other high-performance polymer composites [1096]. Microfocus tomography is useful in damage detection of various continuous-fiber metal matrix composites [1097]. A real-time CT system was also employed to characterize and monitor the growth of defects in composite materials as they undergo destructive testing [1098], High-resolution x-ray tomography also enabled the measurement of the growth of silicon carbide in a woven Nicalon-fiber composite during chemical vapor infiltration, to measure the densification within individual fiber tows and to follow the closure of macroscopic pores in situ [1099]. The microstructure of a chemical vapor infiltrated SiC/SiC ceramic matrix composite was also quantitatively characterized using three-dimensional maps obtained from CT [1100].
Rubber. Computed tomography was utilized to assess the aging of carbon-black-filled materials, and to study the thermo-oxidative degradation and stabilization of rubber materials [1101, 1102, 1103, 1104, 1105]. Microtomography was employed to image the internal structure of carbon-black-filled isobutylene-p-methylstyrene-pbromomethylstyrene (PIB-PMS/BrPMS) curing bladders before and after use-to-failure in the manufacturing of automobile tires [1106].
Manufacturing. CT is a useful tool in manufacturing, particularly in rapid prototyping, reverse engineering and meteorology [1107]. Rapid prototyping refers to processes used to manufacture prototype models of physical objects from CAD (computer-aided-design) data sources by constructing parts gradually, layer-by-layer. CT can be useful in this regard by generating the layer-by-layer information needed to produce three-dimensional numerical representation of scanned components for which parts are to be produced [1107]. In this regard, CT is also useful in generating the CAD data for older designs for which no CAD data are available; such data are needed in many modern numerically controlled machining tools. CT data can also be used in meteorology, to check the dimensionality of a manufactured component, by comparing threedimensional rendered data obtained from CT to those of the design data to ensure consistency.
636
Radiation Probing, Gauging, Imaging and Analysis
Multiphase Flow. X-ray tomography is also useful in multiphase flow studies. For example, it was used to investigate multiphase flow in packed beds [1108, 1109, 1110] and to measure the void-fraction distribution in vertical annulus gas-liquid two-phase flow [978] and in testsections representing pressurized water reactor rod bundles [1111, 1112]. Gamma-ray tomography, applied mainly to image dense objects, was used to measure the void-fraction spatial variations in an air-water bubble column [1113]. Solidification. A CT system was developed for monitoring the progression of solidification in metal (pure aluminum and its alloys) casting melted in a resistance heater furnace, using a 6 MeV linear accelerator to produce a series of time-lapse images showing the movement of the liquid/solid interface during solidification [1114, 1115, 1116, 1117]. The solid fraction of a growing mush generated by directional solidification of aqueous ammonium chloride solutions was also determined by x-ray tomography [1118].
Concrete and Asphalt. A mobile CT unit (employing a source) was designed for inspecting reinforced concrete columns [1119], while pieces of structural concrete were imaged with CT [1120]. Microtomography was applied to the detection of internal damage and measuring crack growth in small mortar cylinders of Portland cement loaded in uniaxial compression, to resolve internal features that are only a few microns in size [1121], and to study the aggregate structure of asphalt concrete [1122]. CT was also used to compare quality and physical conditions of asphaltic mixtures of field specimens [1123, 1124, 1125, 1126]. Exploration. In petroleum exploration, x-ray CT was used to study the swelling and swelling-induced fracturing of cylindrical samples of drained shale in contact with water-based mud placed in a central cylindrical borehole [1127]. Frequent CT images were taken over a 24-hour period (allowing detection of subtle features during swelling), and used to generate quantitative maps of density, subtracted time lapse images, and three-dimensional reconstructions to map failure and fracture patterns. Mud/shale interactions were also studied with x-ray CT in well-bores modeled using steel vessels [1128].
Nuclear Materials. High energy, 2 MeV x-rays were used in the characterization of nuclear waste drum, along with the energy spectrum of the gamma-rays emitted by nuclear materials, to inspect and categorize radioactive waste as low level, transuranic, or mixed waste [1129]. To-
Imaging
637
mography of radioactive reactor fuel samples, pellets and bundles, was performed with radioisotopic source and after subtracting the background radiation (with proper shielding of the object) [1130]. Aerospace. In the aerospace industry, high-energy (megavolt) x-rays were introduced for CT imaging of large and dense objects, such aircraft structures [1131]. Reference [1132] reported the use of CT, with x-ray sources varying from 150 kV to 9 MV, for various aerospace structures and ancillary equipment, such as castings, organic composites and electronics. Three-dimensional CT was also used for rocket motor inspection [1073].
Others. Computed tomography is currently used for inspecting passenger luggage at airports [1133, 1134]. It was also used in the inspection of electrical components and printed wiring assemblies [1135]. A field-transportable CT system (using 160 kV x-rays) was devised for inspecting wooden power poles [1136]. In studying geological structures, x-ray tomography was applied to sandbox experiments to analyze the kinematics of evolution, as well as the three-dimensional geometry of faults in basement-controlled wrench faulting [1137]. A dosimeter consisting of an ion chamber and a housing containing electronics [1120] was also imaged with CT. X-ray tomography was also utilized to image a fibrous polypropylene cartridge filter, and in the investigation of Egyptian mummies [142] Utlrafast. Ultrafast CT scanning systems are emerging, where the scanning process is sped-up by the sequential emission of x-rays from many small individual x-ray sources (targets) surrounding the object. These source are triggered by sequential and rapid electrical switching of an electron beam, see for example reference [1138]. Ultra-fast x-ray tomographic scanners enable the studying of fast-transient multiphase flow phase-distributions [1139, 1140]. 13.4.1.1
Region-of-Interest Imaging
Region-of-interest imaging with computed tomography (see section 6.5.2) was used in a number of applications. As summarized in reference [1141], these applications include: detection and geometrydetermination of shrink cavities in valve castings; imaging the geometry of localized defects in electrical insulators due to electric discharge and of extended defects in thin-walled tubes; and the determination of pore size in ceramics. A real-time region-of-interest-imaging system, with gamma-ray transmission tomography, was also developed to determine
638
Radiation Probing, Gauging, Imaging and Analysis
and control the shape and position of solid-liquid transition in semiconductor manufacturing [1142]. 13.4.1.2
Computed Laminography
This is an approach for imaging flat extended components that are difficult to image with conventional tomography, where the extended size of the plane prevents the accumulation of transmission projection in directions tangential to the plane. The laminography method, discussed in section 13.1.8, provides a limited number of projections that can be utilized in the numerical reconstruction of the images of the plane [1143]. The limited number of projections provided by laminography is compensated for by introducing some a priori information. Numerical reconstruction also removes the background component caused by points outside the focal plane, thus producing sharper images. Reference [1144] presents the results of using this method for imaging circuit boards and weld seams.
13.4.2.
Neutron Tomography
As with neutron radiography, neutron-transmission tomography is particularly useful for imaging hydrogen within other matrix materials. Reference [1145] calculated the minimum detectable mass-fraction of hydrogen in various elements, for different neutron tomography sources: cold (1 meV), thermal (0.025 eV) and fast (14 MeV). The results are shown in Table 13.1. Examples of reported tomography for hydrogen content include the imaging of: cylindrical iron and polyethylene samples (48 mm in diameter) [1019]; compacted soil to detect the different water content levels and to identify the soil composition [1146]; inspection of aircraft fan blades to detect very low levels of hydrogen in a titanium jet engine blades of fully assembled and partially disassembled aircraft [1147, 1148, 1149, 1150, 930]; evaluation of hydrogen content in metallic samples (nickel samples containing a solution) [1151]; detection of corrosion of aluminum, due to build of [1152]; imaging of aircraft honeycomb structures glued between aluminum plates [1152]; and imaging of water in a carnation flower [1153]. Neutron tomography was also used to examine damaged reactor fuel assemblies [928]. Computer tomography was also applied to the analysis and restoration of archaeological samples, for the investigation of small bronze objects [1154]. Reference [1155] suggested the use of digital read-out of charge-coupled devices (CCD’s), along with a scintillating screen and a lens system, in neutron tomography, for fast data acquisition and enhanced spatial resolution.
Imaging
13.4.3.
639
Scatter Imaging
Radiation scatter imaging has also been used in some applications. The main advantage of scatter-imaging systems is that they do not require, like transmission, access to two opposite sides of the object, thus enabling, if necessary backscatter imaging. In addition, images obtained with Compton scattering provide a direct indication of the electrondensity of the material, since the Compton scatter cross-section is directly proportional to density, (see section 3.4). However, as discussed in section 7.2.1, the attenuation of photons before and after scattering weakens the scattering signal, thus this technique is best suited for imaging low electron-density (low atomic-number materials). However, a linear accelerator (6 MeV) as the photon source allowed imaging through a thick and dense wall (8 mm) of steel [1156]. A standard guide for x-ray Compton-scatter tomography is available [1157]. The backscatter imaging of gamma rays (88 keV from was used to detect a corrosion flaw in an aluminum block [1158, 1159], while x-ray backscatter tomography was used to measure the thickness of multilayered walls of light composite materials or denser components provided by powder metallurgy [1156]. Ninety-degree scattering of (662 keV) collimated photons was also used for imaging dense inclusions (lead or copper) in a lighter matrix (aluminum) [181]. Reference [1160] lists the following industrial applications of Compton backscatter tomography: detection of cracks, voids, and inclusions in composite materials, inspection of offshore structures, and inspection of concrete for steel rebar and void enclosures, inspection of aircraft, automobile, and nuclear power industry components. The scattering of fast (14 MeV) neutrons was also used to image the flow of boiling water in a pipe [228]. A combination of gamma/neutron transmission and scatter imaging was proposed for inspection of cargo containers [1161]. While neutrons
640
Radiation Probing, Gauging, Imaging and Analysis
are more effectively slowed-down by interactions with the hydrogen nuclei, gamma-rays are (Compton) scattered by the atomic electrons, hence are more affected by heavy elements. Therefore, the scattering of neutrons and photons provide different but complementary indications. The transmission of neutrons and photons also further confirm the scattering indications, since the intensity of transmitted neutrons tends to be inversely proportional to the hydrogen content while that of photons decreases with increasing content of heavy elements. The combination of these four indicators was proposed for the detection of contraband materials, such as explosives, agriculture products and large sums of money.
13.4.4.
Emission Tomography
Positron emission tomography had found use in some industrial applications. Using water labeled with a compound containing a positron emitter the flooding of water through a porous sandstone saturated with brine/oil was imaged with positron-emission tomography (see section 8.8.3) [1162]. The same reference reported the use of the technique to image the dehydration of water-in-oil emulsions. Photoninduced positron-annihilation radiation-emission was also considered for imaging dense materials, due to the high probability of pair-production in such materials [736, 733]. The tracking of a single small labeled glass bead was used to image the motion of particulate solids, by monitoring the two 511 keV photons associated with the annihilation of the emitted positrons [1163]. The mapping of neutrons emitted from a nuclear weapon was also considered for distinguishing between different types of warheads and missiles, for treaty verification purposes, using neutrons produced by the spontaneous fission of the plutonium in nuclear weapons [1164]. Emission tomography with sources placed within the fluid container was also considered for industrial flow visualization [1165].
13.4.5.
Proton Tomography
Proton beams are also used in computed tomography, with energies up were to 230 MeV [1166]. Proton beams (5 to 7 MeV) focused to 5 used to perform microtornography on capillary tubes and low-density foams, by measuring the residual energy transmitted through the sample. This technique was also used to image direct drive inertial fusion confinement target [1167], and the density of a scorpion stinger [1168].
Imaging
13.5.
641
Imaging for Material Content
Relying on the principles of composition analysis discussed in chapter 12, a number of imaging techniques have emerged to provide material-distribution images. Example applications of these methods are discussed here.
13.5.1.
Dual-Energy Imaging
The ability of dual-energy radiography, discussed in section 6.5.3, to distinguish between organic and non-organic materials, by their density and atomic-number, had made it possible to use this method to image airport passenger luggage for the detection of contraband materials, particularly explosives [1169, 1170, 1171, 1172]. A tomographic system for the same purpose was also developed [1173]. An isotope-based system for for imaging cargo containers has been also considered, using for low-energy photons [1174]. A syshigh-energy photons and tem that uses two energy-groups of an (1.11 TBq) source was also investigated; with a 310.4 keV group containing the 296.0, 308.5 and 316.5 keV energy lines, and a 469.1 keV energy representing the 468.1, 484.6 and 489.1 keV lines [1175]. Dual-energy neutron tomography was employed to image the distribution of water through porous rock [1176]. The use of dual-energy enhances the imaging of small amounts of hydrogen by selecting the second neutron energy so that the other neutron absorbing materials have about the same cross-section in both energies, with the first energy being in the subthermal range where the hydrogen cross-section is highest. Time-of-flight energy discrimination, along with a moderated pulsed-neutron source, was used in this application. The ability of dual-energy (high and low) x-ray imaging to distinguish materials, see section 12.2.2, was used to determine the distribution of water, air, and solids in soil, as well as the soil’s dry bulk density (with 80 kV and 120 kV x-rays) [1177]. Multiple energy x-ray tomography was also suggested for use in imaging mineral samples to determine their principal components [1178, 1179].
13.5.2.
Critical-Edge Tomography
The critical-edge method of elemental identification, discussed in section 12.2.2.1, which uses a tunable photon source that matches the Kabsorption edge of the element of interest was used to image, using transmission tomography, the concentration of uranium in a sample of pitchblende (an ore composed mainly of [1180, 1181, 1182]. The method was also applied for the identification of elements such as Zr,
642
Radiation Probing, Gauging, Imaging and Analysis
Nd, Ba and Sm, using Mo, Sb, Cs, Ce and Gd filters in a boric acid matrix [1183].
13.5.3.
Transmission / Scatter Imaging
As discussed in section 6.5.1, by combining transmission tomography (section 6.4) and scatter tomography (section 7.7), density and composition (atomic-number) information can be obtained. Reference [1184] achieved that by performing these measurements separately using monoenergetic photons: the 60 keV of for transmission, and the for scattering. On the other hand, references [163, 164] 662 keV of presented an x-ray (102 kV) algorithm that relies on recording simultaneously the transmission and scattering measurements. While scatter imaging with photons provides electron-density maps, transmissiontomography reconstructs the total cross-section images that contains both electron density, via Compton scattering, Eq. (3.51), and strong dependence on the atomic number, through the photoelectric effect, Eq. (3.30). While reference [163] used the total cross-section obtained from transmission tomography to approximately correct for the attenuation factors associated with the scattering process, Eq. (7.12), reference [1184] applied a constrained least-squares process to deal with the nonlinearity of the problem (see section 7.7.3). X-ray scattering can also be used, along with transmission-radiography, for detecting explosive materials in passenger luggage [1185], where a rotating chopper-wheel and a stationary slit are used to form a thin beam that raster scans a bag. Either backscattered or forward scattered photons are detected, and used in combination with transmission to provide a density and atomicnumber indications. Within the x-ray energy used, 100 to 140 keV, the photoelectric-effect will still be dominant for metals, suppressing both the transmission and scattering signals. On the other hand, for common organics, Compton-scattering dominates in both measurements, without affecting much either indication due to their low density. Explosive materials, and some narcotics, on the other hand, influence both indications more strongly that most organics but less effectively than metal, thus enabling their detection. 13.5.3.1 Resonance Imaging Radiographic elemental images can also be obtained by fast-neutron transmissions for elements that exhibit resonances in their cross-sections, such as C, N and O, as explained in section 12.1.3. With a pulsed source, and time-of-flight energy measurements, elemental tomographic images were obtained [173, 661, 1186]. Resonance absorption of photons was also considered for imaging of cargo containers to detect contra-
Imaging
643
band materials such as explosives and narcotics [1187, 1188]. Explosives are detected by their high nitrogen concentration via the resonance absorption of 9.17 MeV photons, produced by the reaction, while narcotics are detected by their high chlorine via the resonanceabsorption of 8.21 MeV photons produced via the reaction. These gamma producing reactions require, respectively, the use of protons (produced in an accelerator) of energies of 1.75 or 1.89 MeV and targets employing or Tomographic images are produced from the preferential absorption of these gamma-rays by recording the intensity of the transmitted radiation at different orientations, by rotation and vertical translation of a baggage carousel, or a cargo container. The dip in the neutron cross-section of iron at 24.3 keV (an antiresonance) makes it easier to detect inclusions in iron using iron-filtered neutrons. A time-of-flight neutron radiography/tomography was used in [1189] to detect the presence of 1 mm thick copper within an iron block of 0.20 m thick, and to image the internal structure of cylinders made of Cu-Fe-Pb and Cu-Fe-Al. The time-of-flight technique, see section 4.5.5, facilitates the acquisition of neutron-transmission measurements at the anti-resonance energy 13.5.3.2
Bragg Cutoff Imaging
Below the Bragg cutoff, see section 3.5.5.1, the neutron cross-section drops significantly. This phenomenon can be used to detect the presence of a material by radiographing with cold neutrons at energies just above and below its Bragg cutoff energy. The presence of such material would be indicated by an abrupt enhancement in the amount of transmitted neutrons at energies below the cutoff energy. Time-of-flight measurement with a pulse neutron source facilitates the performance of such elemental imaging. This technique is called time-gated energy-selected (TGES) neutron radiography, and has been applied for the detection of beryllium (5.2 meV) and carbon (2 meV) [1190].
13.5.4.
Photon Coherent-Scatter Imaging
This method of imaging, discussed in section 7.7.4, was applied to the detection of explosives in luggage, taking advantage of the unique diffraction patterns of the investigated material [1191, 1192, 1193, 1194, 1195, 1196, 1197]. The technique was applied to food materials for detecting foreign bodies (such as soft plastics in meat and confectionery products), natural contaminants (such as fruit stones in processed food), and distinguishing between fat and bone tissue in meat processing applications [312]. Reference [1198] reported the detection of macrolon in choco-
644
Radiation Probing, Gauging, Imaging and Analysis
late, blue foil in bacon, cherry stones in cherry jam and wood and bone in chicken breasts, while reference [1199] showed images demonstrating the detection of plastic and glass fragments contaminants in a chocolate phantom. Small-angle scattering complements conventional transmission tomography by providing composition indications [1200, 232], and enables the characteristics of some light materials, such as plastics, that cannot be resolved by transmission tomography alone [1201]. Reference [1202] discussed a number of potential industrial applications of coherent x-ray scatter including: mixing or ice formations during the freezing of food products; discrimination between oil and water; precipitation of colloids in chemical processes, sorting of plastics in recycling facilities; and detection of gem stones in minerals..
13.5.5.
Emission Imaging
Emissions produced by the reactions discussed in chapter 8 can be used to produce tomographic images. For instance, the characteristic gamma emission from thermal or neutron activation of certain elements can be utilized to image objects for their elemental content. This approach was employed in imaging small and large objects, from airline passenger luggage to shipping containers, for the purpose of detecting contraband materials [1203]. The 511 keV photons emitted by the annihilation of positrons, produced following the reaction were also considered for imaging nitrogen in containers for the purpose of detecting nitrogen-rich explosives [627]. References [1204, 1205] presented a nitrogen-camera system for imaging the nitrogen content of concealed explosives by monitoring the gamma-rays detected after irradiating the object, pixel-by-pixel (20 x pixel area), with a pulsed beam of 50 MeV electrons. The camera itself is made a set of scintillator detectors. These electrons produce photons that in turn activate a variety of elements in the volume around the irradiated surface, but (a positron emitter, 11 ms halflife) and (a beta emitter, 20.2 ms half-life) are produced with high yield via the reactions and and In addition, neutrons are also produced by the induced photons interacting within the accelerator and surrounding materials. As these neutrons are slowed-down and captured they will also produce activation gammarays within a short period (about 10 ms following the incident pulse). Gamma emission will continue for another 30 ms or so, as a result of the bremsstrahlung of the decay beta-radiation, the de-excitation of (produced by the beta decay of and the annihilation of the positrons emitted by These gamma emissions, in total, constitute the nitrogen camera signal, although not all these emissions are attributable to
Imaging
645
the presence of nitrogen. However, the main gamma-emitter that competes with nitrogen is the gamma emitted by the photoactivation of which although present at low abundance (1.1%) has a high photoactivation cross-section (with a threshold energy of 25.1 MeV). However, emissions from the photoactivation of can be discriminated against, in principle at least, by the energy of the emitted radiation, since only produced by nitrogen activation generates 511 keV positron annihilation radiation. Also, the maximum energy of the positrons emitted by the decay of is about 16.3 MeV, which is higher than the 13.37 MeV maximum energy of the beta of with the result that the bremsstrahlung photons produced by are higher in energy than those produced by This feature can be used to further discriminate between the two isotopes, hence the elements they are produced from. Another way of discriminating against produced by activation is to employ a beam of energy below the 25.1 MeV threshold-energy of the reaction, which is also below the 30.6 MeV thresholdenergy of the reaction but is above the 17.5 MeV threshold energy of A combination of emission and transmission imaging was proposed for evaluating the radionucluide content of drums containing low-level waste [1206]. Using an external source, transmission tomography is performed to obtain an attenuation-coefficient image of a section. The obtained attenuation-coefficient, adjusted for energy dependence, is then used in emission imaging to correct for the attenuation of the emitted radiation from its point of origin to the detector location. In this technique the energy spectrum of the emitted radiation is used to identify the radioactive nuclide in the drum. Particle-induced x-ray emission (PIXE), discussed in section 8.7.3, can also be used in imaging small samples (less than a few mm), by monitoring the emitted x-rays and relating their energy to the characteristic energy of the originating element. References [1168, 1167] introduced such a tomographic systems, using microprobe ion beams, to image the distribution of Zn and Mn in the sting of a scorpion [1168], Br and I in a direct drive inertial confinement fusion target [1167], and Ni or Cu in metal wires [1167].
This page intentionally left blank
PART IV: DESIGN
This page intentionally left blank
Design
649
The most challenging task for a designer of a radiation-based device is perhaps to justify its use in industrial settings that are adverse to the use of ionizing radiation. In Chapter 1, some justifications for the use of such devices, v.s. the use of other non-radiation techniques, are presented. However, reference [1207] provided an excellent summary of the features that one can use for promoting the application of radiation instruments in measurement and control. These are: Non-Contact: no direct contact with the inspected medium is required, thus measurements with high temperature, high pressure, toxic, acidic, viscous or otherwise “difficult” process materials are made easier.
External: equipment used, sources and detectors, are placed outside the interrogated system so that the devices can be fitted while the plant is on-line. They are also readily accessible for checking and maintenance.
The exception is when a radioactive material needs to be introduced within the interrogated object, such as when radiotracers are employed. But even then, the measuring equipment (detectors) are usually external to the material. Reliable: the failure rate of radiation devices that use radioisotopes is quite low, since such sources are self-powered and require no maintenance (except for leak checks every few months, see chapter 5). The technology of nuclear electronics is also well proven. Therefore, the mean time between failures is low.
System breakdowns are often caused by mechanical components. The designer should keep in mind that the mean-time between failures is determined by that of the weakest component of the system. However, radiation imaging systems with moving parts (such as scanning mechanisms) are routinely used in airport luggage-inspection and in medical diagnosis. Energy Efficient: the power requirements of radiation detection equipment is generally quite low, and no power is needed to generate radiation when radioisotopes are used. Therefore, such devices can be made “intrinsically safe” from an electrical point of view.
However, the use of accelerator-based radiation generators entails the utilization of high-voltage power supplies.
Radiation Probing, Gauging, Imaging and Analysis
650
Uniqueness: in many cases conventional techniques cannot meet all measurement needs, and radiation devices can provide information that is not simply attainable by any other means. There are, however, many situations in which a nucleonic gauge provides the only sensible answer to a measurement and control problem.
Regulatory Burden: the effort associated with the licensing and operation of radiation devices is perceived by some as being taxing. However, such effort ensures a safe and secure operation and use. Regulations are usually introduced for a reason: to ensure safety of workers and the public. Moreover, there is no reason why the routine regulatory checks need be any more time-consuming than those associated with any other plant-installed instrument.
Cost: radiation devices tend to be more costly than other conventional devices. However, taking into account their non-intrusive nature, the saving offered by radiation devices can offset their cost; by eliminating the need to alter or modify an existing plant system to accommodate an instrument, and by avoiding the shutdown of plant to install, repair and maintain instrumentation devices. The savings from this source [installation and commissioning] alone will, in the majority of cases, exceed the cost of the instrument.
As reference [1207] states: Nucleonic gauges can, therefore, compete on an equal footing with conventional gauges and should certainly be among the instrument options considered for any plant or process.
The same reference [1207] concludes by stating: Instrument engineers are finding that for difficult measurement problems, nucleonic instruments possess advantages offered by no other type of instrumentation. There is also an increasing awareness that properly installed, they present no hazard to the work-force. On the contrary, by providing what is in many cases superior control of potentially hazardous process materials, they are a positive enhancement to the safety of operating plant.
Reference [1207] supports the above quoted statements with two case histories: density/level gauges to control foam/liquid in oil gas separators, and control of boric acid flows. One can make similar arguments for most of the applications reported in Part III of this book. Marketing. Successful implementation of radiation-based technologies requires good marketing. Strategies for good marketing of radiation devices include [1208]:
Identifying the needs of a potential user.
Design
651
Demonstrating how a device, whether conceived, developed or available, meets the user’s requirements. Showing the economic and operational benefits of the device. Identifying, if necessary, any adjustments or improvement that may be needed for a device to better meet the user’s requirements. Overcoming the apprehension of potential users and their resistance to accepting radiation technology by an honest approach to the matter, referring to similar systems already in place in other sites, and comparing the risk to other competitive methods that may require contact, intrusions or are simply incapable of meeting the user’s needs. Convincing a potential user of a device is only the first step in the design process. Many technical design aspects and considerations must be dealt with, to provide an accurate, fast, safe and a minimum-cost device. This Part of the book discusses these design issues, which are defined in more detail in chapter 14.
This page intentionally left blank
Chapter 14 PERFORMANCE PARAMETERS AND DESIGN ASPECTS
14.1.
Performance Parameters
A measuring device provides an indication of a physical parameter. The design of a measurement system must, therefore, deal with both the nature of the measured value and the corresponding physical parameter. In radiation devices, the measured value can be a count (pulse) rate or a current or a voltage corresponding to the measured pulses. A pulse-height distribution can also be measured, from which the energyspectrum can be derived. In any case, one needs to find a relationship via a between the physical parameter, P, and the measured quality, measurement model, M, as discussed in Part II of this book. That is:
where M(P) designates that fact that is a function of P, with the function determined by the model M, and K is a system-constant that incorporates system parameters that are not included in the measurement model, such as the source strength, detector efficiency, etc. The constant K can be obtained by calibration. Alternatively, calibration and P. can provide a graph, or an empirical relationship, between The measured parameters, and the corresponding physical parameters, can themselves be functions of the following independent variables:
with being a vector in space defining the spatial dependence of P or refers to the time dependence, and designates the concentration of a species (atom or nucleus) of type i that influences P and and N is the total number of species considered. In global gauging 653
654
Radiation Probing, Gauging, Imaging and Analysis
(chapter 11), where an indication representative of the entire volume is and P are only functions of and the At steady-state, obtained, becomes dependent only on the composition of the examined material. For a fixed composition, becomes a direct indication of P, with the latter being for example, thickness, density, etc. Probing (chapter 10) in space, or at a aims at obtaining an indication at a fixed position, number of such positions, one at a time. In imaging (chapter 13), and but for tomography, where an image is obtained P are functions of are obtained at given values and become only at a section, P and function of and In elemental mapping, one aims at obtaining an but can also be at a certain point indication that is a function of for probing, over the entire volume (independent of for bulk (at indication, or a function of for imaging. All the above mentioned indications can be time-varying, which requires one to pay attention to the dynamic behavior of the measured signal; see section 17.4. Radiation measurements are also subject to statistical fluctuations, and the data acquisition process should be such that a certain level of statistical confidence in the results is attained. The design of a system should also be statistically optimized, as discussed in section 14.2. In general, designers aim at determining and optimizing the following parameters: Accuracy. This is the difference between an “indicated” value and a “true” value. Designers should aim at minimizing this difference to attain high accuracy. Verification against independent measurements or calibration can be used to measure or assure the accuracy of obtained measurements. Calibration of a device during operation, or every time the device is restarted, is needed to guarantee the accuracy of the device under different operating conditions.
Precession. One of the main design goals is to achieve a high degree of repeatability and reproducibility of a measurement, obtained for the same value of P under the same setup conditions. A low degree of statistical spread in the measured indication is required for high precession. Designers need also to specify the smallest and highest obtainable indication value, i.e. the range of the device. Tolerance is the term used to describe variation about the mean output of a device for a given exact condition. The tolerance of a device may vary with the range of
Performance Parameters and Design Aspects
655
measurements. In such a case, the designer must report the tolerance of the device at different ranges of operation. The obvious approach to obtaining good precision is to increase either the counting time or the source intensity. Statistical consideration, see section 14.2, can be used to determine the counting period for a given count rate provided by a certain source strength. While in some applications a long counting time may be acceptable, it is often desirable to obtain precise measurements at high sampling rate, i.e. within a short counting period. Radiation safety considerations may also constrain the intensity of the source that can be utilized to avoid a bulky, heavy or cumbersome shielding. Even if a large source can be used, dead-time and pile-up loses (see section 4.5) may impose a limit on the source intensity that can be used while being able to electronically process the detected signals. Resolving Power. This is the smallest change in P that can be detected with a certain confidence level [1209]. The resolving power, is a measure of the precision in determining a physical parameter P. Two parameters, and that are close to each other can be distinguished from one another if the difference in their value is greater than the statistical uncertainty associated with their value. At a 68% confidence level, see appendix G, the statistical error associated with the difference in value between and is equal to where refers to the statistical variance which is assumed to be equal to the measurement in accordance with Poisson statistics (see appendix G). A device measures instead of P, but is related to using relationship (14.1), by:
where the measurement model of Eq. (14.1) is assumed to be a continuous function, enabling the last step in Eq. (14.2). When and are where and are the close in value, and measurements corresponding to respectively. Then, one can also assume that Therefore, the smallest measurable actual change in P, or the resolving power, is given by:
Note that, when the measurement ceases to change with P, i.e. when would approach infinity, providing no resolution power, as one would expect.
656
Radiation Probing, Gauging, Imaging and Analysis
Signal-to-Noise ratio. Generally refereed to as S/N, the signal-tonoise ratio is defined as:
where is the fluctuation of the signal around which can be caused by statistical variation or electronic noise. Obviously, the value of S/N should be as high as possible. The effect of statistical fluctuations is addressed in appendix G. Other sources of noise may be viewed as those introducing a constant relative-error (electronic noise) or a constantabsolute error (systematic instrument or indication error). When these sources of error are statistically independent from each other their variability can be added for a measured signal as follows [1210]:
where refers to the variance due to statistical fluctuations, is the relative error due to electronic noise and is the absolute systematic error. Electronic noise is generated by detectors and associated electronics. Such noise can be due to changes in temperature (semiconductor detectors and photomultipliers), magnetic (photomultipliers and signalprocessing electronics), and power supply/ high-voltage instability (proportional counters and electronics). While minimizing the source of noise is certainly desirable, strengthening the detected signal is also a sure way to enhance the S/N ratio. The signal can be intensified by using an efficient detector for the radiation type and energy at hand, matching the output of the detector with the proper amplifying electronics, (e.g. matching the frequency of the light emitted by a scintillator to the type of cathode used in a photomultiplier), and using the proper preamplifier type and setting (see section 4.5). Signal-to-Background ratio. Referred to here as S/B, the signalto-background ratio is expressed as:
where is the background measurement, due to radiation scattering, source leakage, natural radioactivity, etc. However, sometimes, system noise is also viewed as part of the background signal, particularly to account for the statistical fluctuations of the background signal as discussed in appendix G. A signal that is very close in magnitude to the background signal is vulnerable to signal noise, as
Performance Parameters and Design Aspects
657
the noise may make the signal closer in value to the background signal. The value of imposes a limitation on the resolving power, i.e. the detection limit, as can be deduced from Eq. (14.3) by setting where is the recorded gross-measurement. Then, (assuming that is independent of P). Using Eq. (14.3), with this leads to the following “lower limit of detection ” [1209]:
Eq. (14.7) provides a quantitative estimate of the effect of the background measurement on the detection limit which can be useful in determining whether effort in lowering the background signal is worthwhile. Contrast/Sensitivity. Designated here by C, the contrast is the relative change in due to a change in P, or:
A good contrast, i.e. a high value of C, assures that a small change in the physical parameter, P, produces a large change in the measured paramObviously the contrast affects the resolving power, Eq. (14.3), eter, and the lower limit of detection, Eq. (14.7). Resolution/Precision. Resolution is the detectable change of any of the independent parameters listed in relationship (14.1) that correspond to the smallest measurable change in say That is,
where
is the concentration of element
Stability. Allowance should be made to ensure stability against shortand long-term variations [410]. Short-term and long-term variations in system and environmental conditions should be taken into account. Short-term variations may include temperature, pressure, high-voltage
658
Radiation Probing, Gauging, Imaging and Analysis
supply, magnetic noise, etc. Long-term effects may include decay of a radioactive source or deterioration of the target in an accelerator-based source, changes in detector characteristics, etc. Periodic verification and calibration of the system is an obvious necessity when dealing with longterm effects. On the other hand, short-term effects may be handled with compensating electronics, comparative measurements with a standard well-controlled object, or by post-processing compensation for ambient effects. Artifacts. In an imaging system, a number of image artifacts can be produced, and effort should be made to eliminate or minimize such artifacts. An artifact is any image feature that does not exist in the imaged object. Since the actual details of an imaged objet may not be known, artifacts can make it difficult to interpret a recorded image. However, understanding the nature and sources of artifacts that may be introduced by a certain imaging system can be helpful in interpreting images produced by that system. The following types of artifacts may exist [160]: Physical Artifacts. These are produced by idealization inherent in the interpretation process. For example, in a transmission-based system, scattering can produce artifacts in the image indicating less attenuation than actually is the case. With a multienergetic source, beam hardening produced by the absorption of lower-energy radiation early in the beam path, will also produce an apparent decrease in the attenuation capacity of the object. Similarly, in a scatter-imaging system based on singlescatter events, multiple scattering can result in an artifact indicating an apparent increase in the amount of scattering. In emission-imaging, artifacts are produced by radiation attenuation which reduces the amount of radiation detected, and by scattering that can increases its strength . Geometric Artifacts. Object geometry (curved or irregular), source geometry (size, uniformity and divergence) and detector geometry (size and collimation) can also produce artifacts by creating irregular image voxels. Misalignment of the source-object-detector geometry also produces geometric artifacts, called parallax artifacts. Systemic Artifacts. These are caused by effects other than those introduced by physical or geometric reasons. Such factors include, source irregularities, detector drift and afterglow (i.e. delayed response), electronic noise, etc.
Performance Parameters and Design Aspects
659
Reconstruction Artifacts. In computer-reconstructed imaging, the image reconstruction algorithm can introduce its own artifacts, due to error propagation, round-off error, etc. Figure-of-Merit This is a design parameter that combines
more than one feature, and is used when improvement in one parameter
comes at the expense of other parameters. For example,
provides the best possible combination of a strong signal, and a high contrast. A figure-of-merit can also incorporate parameters such as cost, radiation exposure, size or weight of shielding, etc.
14.2.
Statistical Optimization
The measurement model of a particular technique or a system can be used along with the provisions of statistical counting discussed in appendix G, to design for optimal statistical conditions. Let us reconsider the generalized measurement model of Eq. (14.1):
. Assuming that the function M is a continuous function, so that it can be
so that: inverted to determine the value of P, from
where is a function that relates to P, and is in effect the inverse of the function M(P). In order to determine the value of P with highest accuracy, its error should be minimized. The statistical variance in P, Var(P), is related to the statistical variance, in the measurement by the rule of combining errors, Eq.(G.4), as follows:
where refers to the error in P, which is equal to as discussed in appendix G. The nature of the function, M, and its inverse, G, in a radiation-based application depends on the type of radiation and its energy, which in turn determines the value of the macroscopic crosssection, of the inspected material. For minimum error in P, one must choose so that:
Using Eq. (14.13), this leads to:
for optimum counting statistics, i.e. minimum error in statistical counting for a given source strength.
660
Radiation Probing, Gauging, Imaging and Analysis
Transmission. To demonstrate the above optimization process, let us
consider the use of a transmission technique, modeled by Eq. (6.1) as:
where I is the measured intensity for a material of thickness, is and is the cross-section the measurement in air (i.e. when of some type of radiation at some energy that needs to be optimized. and Comparing Eqs. (14.16) and (14.1), one can see that The inverse of Eq. (14.16) is given by
which upon comparison with Eq. (14.12) shows that
With I being the measured radiation count rate, according to Eq. (G.3)
the statistical variance in a count is equal to the count itself, that is,
Using relationship (14.15), one can show that:
This is the well-known condition for optimizing transmission-based systems, see for example reference [238]. The reader can verify that the second derivative of the error in P, hence the error in i.e. is positive at which confirms that the error in is minimum at Note that the same condition arises when optimizing a transmission system for best resolution, see Eq. (14.26), since in essence good counting statistics leads to a better ability to resolve changes in system parameters, i.e. better precession. The condition of Eq. (14.18) suggests that the radiation type and energy should be chosen such that it provides a total cross-section, Eq. (14.18) is equivalent to stating that that is the thickness of the material should not exceed the equivalent of two mean-free-paths of the radiation used. Under this condition, the average number of collisions the radiation encounters in a material would be equal to 2. Since not all collisions will lead to scattering towards the transmission detector, the buildup effect, see section 6.1, would not be too severe under these optimized conditions to violate the inherent assumptions behind the measurement model of Eq. (6.1), refer to section 6.1. The above process is equally applicable if one is to measure the value or any other quantity linearly related to it (such as the electronof density in the case of Compton scattering.) The reader can prove this and optimizing for Therefore, for a given value of by setting material type, density and thickness, one can select the source type and
Performance Parameters and Design Aspects
661
energy that satisfies the condition of Eq. (14.18) for optimum counting statistics. Instrument Error. A very high count will also reduce the statistical variability in the detected measurement, and subsequently in the evaluated physical parameter, as one can deduce from Eq. (14.13). A very intense radiation source, or counting for a very long period, will achieve this objective. Both such conditions are used in practice to reduce the statistical uncertainty. Even under such conditions of low counting statistical uncertainty, some other instrument error may arise from effects external to counting; e.g. variability in film quality in radiography or instability in the high-voltage applied to a detector. Then, it is reasonable to assume that the variance of the measurement, is indepen-
dent of the optimization parameter, Eq. (14.15), leading to:
and one can set
in
for optimum conditions for instrument error (not related to counting variability). Applying the above condition to transmission leads to the requirement that Off-Optimum Conditions. For transmission measurements, between the conditions of Eqs. (14.18) and (14.19), one can state that the optimum range for operating a transmission-based device is when for best counting and instrument variability conditions. Note that total variance in the estimated parameter is given by:
where the subscript and refer, respectively, to counting and instrument effects. Operating at would ensure minimum error due to instrument variabilities, while operating with would minimize the statistical counting error. At the device would be very sensitive to variabilities in the measurements, that is, a small error in the measured value would lead to a large error in the estimated parameter, since the response curve given by Eq. (14.16) would be quite steep in the sensitivity of to changes in slope. On the other hand, at P would be quite poor, as the response curve would tend to saturate. In or so, it becomes quite difficult to obtain statistically practice, if acceptable measurements with a source of a reasonable strength, due to the severe attenuation of the source. Therefore, a thickness equal to
662
Radiation Probing, Gauging, Imaging and Analysis
is called the “blackness” thickness or “saturation” thickness, beyond which an instrument becomes insensitive to small changes in the system parameters. Complex Problems. The above analysis was performed for a simple case of transmission with a source of a fixed energy, hence a fixed value of and in a uniform medium, i.e. was not a function of distance. The analysis becomes more complicated when dealing with changes in radiation energy and material uniformity, as the measurement model becomes more complex to be amenable to a simple differential analysis such as that presented above. The same situation may rise when dealing with other techniques, where the measurement model is either too complex or may not exist at all. Then, sensitivity analysis using numerical simulations and laboratory experiments will need to be employed. However, when possible measurement models should be simplified, such as by using the concept of equivalent energy discussed in appendix 6.4, to facilitate the performance of the above optimization analysis. The results of such analysis can then be used as an approximate indication of the optimum measurement conditions around which calculations and experiments may be attempted.
14.3.
Design Objectives
The designer of a device should aim at optimizing performance parameters that are relevant to the problem at hand. Such optimization can be achieved by: Selecting the most suitable radiation source. Section 14.4 examines the factors that should be considered when choosing a source. However, such sources can be modulated in direction or energy, or even in some cases intensity, to better suit the designer needs. Section 15.1 discusses the design of source collimators to confine the incident radiation to a particular direction. Methods to alter the energy of radiation emitted by a source, or to confine it with a certain energy range, are addressed in chapter 15. Choosing the most appropriate indication method: transmission, scattering, activation, etc., and the associated physical modification process (section 14.5). Finding the detector that most effectively and efficiently measure the desired parameter (section 14.6). Studying various effect parameters, using calculations and/or experiments (chapters 16 and 17).
Performance Parameters and Design Aspects
663
Reducing the radiation background (section 17.3). In addition, a proper radiological shielding must be provided (section 16.3). Devices employing radioisotopes or particle accelerators must be also licensed with the appropriate regulating authority. Section 17.2 discusses some of the regulatory issues. Many of the design calculations required in the design process can be performed using the powerful Monte Carlo method of radiation interaction and transport simulation (chapter 16). However, such calculations do not usually incorporate all measurement aspects encountered in the laboratory. Thus experimental verification of the design is essential (chapter 17). Experiments are also used to calibrate a device. Lessons learned from the experimental testing process can then be incorporated in the design and construction of a prototype device suitable for field testing (chapter 18). Field testing for performance evaluation can then be followed, lessons from which can be incorporated in the design of the device (section 18.1). The protection of intellectual property associated with a novel device should also be of concern to the designer (section 18.2).
14.4.
Source Selection
Chapter 2 described various types of available radiation sources. If a designer is to rely on a source that readily exists within the inspected material, such as when the material contains natural radioactivity or is radioactive, then the main design effort will in the modifying physics and the detection system. However, when an external source is to be selected, or an internal source is to be introduced, the choice of the source is crucial to the design. The choice of a source relies on the type of modifying physics employed for the detected indication. However, there are some basic source parameters that a designer must be concerned with. These can be summarized as follows: 1 Nature of emitted radiation: photons, neutrons or charged-particles. 2 Method of radiation generation: by machines or isotopic sources. 3 Energy of emitted radiation. 4 Intensity of emitted radiation (number of radiation entities per second).
Note that the source-energy refers to the energy of a single particle, or a photon, while the source intensity is the number of particles emitted per unit time. The above parameters not only affect the selected modification modality and detection system, but also the portability of a device, which
664
Radiation Probing, Gauging, Imaging and Analysis
depends mainly on the size of the source and the associated shielding. More often than not, a source needs to be altered in energy or direction to better suit the designed device, as discussed in chapters 15. This section focuses on the above basic parameters.
14.4.0.1
Source Nature
One can use the following basic facts to choose a radiation source for a given application: Charged-particles: are affected by the electrostatic (coulomb) field of the atom, thus have a limited penetration range, and interact only with the nucleus when they have a high energy. Photons: interact mainly with the atomic electrons, and result in nuclear interactions only at high photon-energy. Neutrons: interact always with the nucleus.
Charged-particles, whether employed as sources, or detected as scattered or emitted radiation, are limited to use in small samples or gases, due to their poor penetrability. The same conclusion applies to techniques employing low-energy photons, as incident or emerging radiation. With such not-too-penetrating radiation, effort must be made to remove any obstacles in the path of radiation, by for instance performing measurements in a vacuumed cell and the use of thin-window detectors. When dealing with light (low atomic-number) materials, neutrons are generally preferred, since such materials are not too rich in electrons to significantly affect photons. On the other hand, charged-particles can penetrate larger sections of such materials, making it possible to exploit the use of charged-particles. Heavy (high atomic-number) materials are electron-rich, thus strongly affect incident photons. However, if a heavymaterial is too thick, photons may not be able to penetrate deep inside the object, but neutrons may. If the source is to be an internal source, such as in radiotracers, charged-particles are usually excluded because of their limited penetrability, which makes it difficult to detect the emitted signal outside the object. The activity released by these particles may be detected by sampling or an intrusive measurements [276]. However, such charge-particles, in the form of open (unsealed) internal sources present a biological hazard, if inhaled, ingested, or absorbed by the skin. Unless charged-particles and photons are energetic enough to produce nuclear interactions, or are sufficiently low in energy to induce atomic excitation, the indications they provide are electron-density dependent, due to the electron-dependent nature of their reactions. On the other
Performance Parameters and Design Aspects
665
hand, neutrons more easily penetrate the nucleus, because they are neutral, and can produce nucleus (hence element) related indications. The selection of the type of radiation can be viewed as an optimization of the cross-section of the material, to provide optimum performance in contrast and/or resolution. This is in essence a source energy optimization problem, see section 14.4.3, applied to various radiation types. For example, in transmission radiography, the optimum spatial resolution is attained when where is the total cross-section of the inspected material and is its thickness, see section 14.2. Therefore, for a given material and a given thickness, one should choose the radiation source type and energy that result in a value of as close as possible to It is the thicker the object that can clear also that the lower the value of be inspected with optimal spatial resolution. On the other hand, if one needs to distinguish between two materials, the contrast provided by one material should be different from that of the other. Since the contrast for radiography, as Eq. (14.22) indicates, is proportional to the larger the difference in the value of for the two materials, the better the ability of a radiographic system to distinguish between the two materials. For this reason, fast-neutrons were preferred, than photons, for radiographing a light material, such as lithium, surrounded by a dense material, such as uranium, due to the larger difference in the neutron cross-sections of the two materials [1026]. The cross-sections in Table 14.1 illustrate this point. The Table shows that, per unit mass, the maximum photon cross-section for Li and U are about equal, while those for neutrons are quite different. The lower fast-neutron cross-sections for these two elements, than those of photons or thermal-neutrons, make fast-neutrons more penetrating of the material.
14.4.1.
Radiotracers
In choosing a radiotracer, the half-life of its radioactive element should be considerably longer than the counting period, otherwise decay corrections have to be introduced. Obviously, the chemistry of a radiotracer material has to be such that it remains suspended or dissolved in the
666
Radiation Probing, Gauging, Imaging and Analysis
material into which it is embedded. The emitted radiation has also to be sufficiently penetrating of the inspected medium and its container so that it can reach a detector located outside the medium. For liquids, the following radiotracers are available in different chemical forms suitable for use in aqueous or organic liquids [445]: (14.959 h, 1.369 and (35.30 h, 0.554.348 and 776.517 MeV), where the 2.754 MeV) and values in brackets indicate, respectively, the half-life and the energy of the principal photons emitted [12]. For gas radiotracers, the following radioisotopes may be used [445]: (12.32 y, beta: 18.587 keV), (109.34 min, gamma: 1.294 MeV), (4.480 h, beta: 0.841 MeV, (5.243 d; gamma: 0.151 keV; 3934.4 d, beta: 0.687 MeV) and beta: 0.346 MeV), where the values in brackets are the half-life, type of radiation emitted and the maximum energy of emitted beta-particles, or the most intense gamma energy for photons [12]. Note that is also suitable for water and steam, as it can be included in the form of (tritiated water). For beta-emitters, the walls of a container need to be equipped with a thin window in front of the detector to allow radiation to exit the system for detection. Other open sources that can be used as radiotracers include [2]: and
14.4.2.
Source Generation
Radiation can be generated either by the decay of a radioactive material (an isotope) or by a nuclear interaction. The latter typically involves the acceleration of charged-particles to an energy that is sufficiently high for the particles to penetrate the field of the nucleus. However, some isotopic sources are based on nuclear interactions without accelerating the incident charged-particles, as in the case of alpha-reaction neutron sources (see section 2.3.1.1) and photoneutron sources (see section 2.3.2). The choice of the type of source production depends on many factors. To assist the designer, advantages and disadvantages of each type of source generation are discussed below. Radioisotopes are generally small in size, but are of limited emission intensity and are subject to reduction in intensity by radioactive decay. Therefore, internal sources are mainly radioisotopes, due to the obvious difficulty of introducing bulky accelerators into an inspected medium. Portable devices also benefit from the small size of isotopic sources. Although radioisotopic sources have the advantage of being self-powered, i.e. do not require external power supplies, they emit radiation continuously thus cannot be turned-off. The latter makes it necessary to equip them with biological shielding at all times. They are also classified as nuclear materials that require special licenses to acquire, transport, use and
Performance Parameters and Design Aspects
667
dispose of. Isotopic gamma sources have also the advantage of emitting discrete and often monoenergetic photons, since the emitted photons originate from the decay of the nucleus. On the other hand, neutrons produced from isotopic sources possess a wide energy distribution, as indicated in section 2.3. Accelerator-based radiation sources have in general features that are contrary to those of radioisotopes. Accelerator-based photon sources, such as x-ray machines (which are based on electron acceleration) have a wide energy distribution, see section 2.2.1. On the other hand, monoenergetic neutrons can be generated via accelerator-based devices, see section 2.3.1. They tend to be bulky and require a power source, but neutron generators also provide highly intense radiation and can be turned off. Therefore, accelerator-based sources can be stored, when not in use, in a non-shielded area. The intensity of emitted radiation can also be controlled by the current of the accelerated incident chargedparticles, while the energy of generated radiation may be adjusted by varying the acceleration potential. However, such radiation generators require special care in operation and maintenance, and in some cases need highly trained and specialized personnel to operate them. Although accelerator-based sources are not subject to radioactive decay, the target upon which the charged-particle impinge may be depleted or damaged. Cooling of such targets may also be necessary at high radiation emission rate. The cost of an accelerator-based source tends to be higher than that of a radioisotope; although for very high intensity sources, radioisotopes may prove to be comparable in cost or even more expensive, if one includes the cost of disposal. The licensing requirements of such devices tend, therefore, to be more lenient than that of radioisotopes.
14.4.3.
Source Energy
The source energy not only determines the penetration depth of the radiation, but also governs the way radiation will interact with the material of the interrogated medium, as discussed in chapter 3. For chargedparticles, the value of the range determines the maximum depth of penetration of the particles, a quantity that is typically small in value. The range of a given charged-particle at a certain energy in a given material can be evaluated using a library such as SRIM-2000 [47], or using the approximations given in section 3.3. Unlike charged-particles which are continuously affected by the electrostatic field of the atom, neutrons and photons can travel some distance without suffering any interactions at all until they encounter an atom to interact with. However, the penetration depth of photons and neutrons can be roughly taken to be equal to about five mean-free-paths,
668
Radiation Probing, Gauging, Imaging and Analysis
since after such distance most of the original beam of radiation would have interacted with the material; only 0.67% of the incident beam survives. This value is arrived at using the transmission model of Eq. (6.1), with the total macroscopic cross-section being equal to the reciprocal of the mean-free-path. The value of the cross-sections for different elements and at different radiation energies can be found in one of the many available libraries such as ENDF [78] for neutrons and XCOM [19] for photons. These libraries also provide the interaction cross-sections for various modes of interactions, thus can be used to determine the suitability of a proposed type of reaction and the possible interferences from other reactions. For an example of source optimization for an x-ray transmission tomography system see reference [1211]. When dealing with multienergetic sources, determining the depth of penetration and the interaction probability is a challenging task, since each value of the source energy will provide a different value for the penetration depth. One can either use a bounding approach that involves employing the maximum and minimum source energies to provide limits for the penetration depth and the interaction probabilities, or use an equivalent single energy (see appendix F) to determine an effective value for these parameters. A more rigorous approach is to employ Monte Carlo simulations to determine these parameters, see section 16.2. If the optimal energy cannot be found in one of the commonly available sources, one of these sources may be modified in energy using moderators in the case of neutrons (see section 15.3), or filters in the case of photons and neutrons (as section 15.2 shows). If the device to be designed involves the use of multiples sources of different energy or radiation type, the designer must ensure that each source provides a significantly different type of indication, otherwise the use of multiple sources would be redundant. For example, reference [1212] studied the criteria for the selection of photon energy in a dual-energy system for oil-water-gas mixture composition measurement. In addition to penetrability, one also should chose the source energy that assures best contrast. Let us consider the case of a radiationtransmission technique, such as radiography, which can be depicted by the exponential attenuation measurement model of Eq. (6.1):
where I is the intensity of transmission at thickness of a material of and is the intensity in the absence of the a total cross-section material. The contrast, C, of such device to a change in due to say the presence of a void flaw, can be expressed using relationship (14.8)
Performance Parameters and Design Aspects
669
as:
High penetrability is manifested by a high value of I, which can be attained, in accordance to Eq. (14.21), by choosing a source that provides normally the highest energy possible. However, the smallest value of reduces the contrast, as dictated by Eq. (14.22). A a low value of figure-of-merit can be defined as:
Then, a source energy that produces a value of that maximizes the value of in Eq. (14.23) will produce the most optimum system in penetrability and contrast. Note that is maximum when i.e. when the mean-free-path is equal to the thickness of the material. to the above problem, by Reference [1025] proposed alternative defining as the time it takes the signal corresponding to a flaw to reach an intensity level five standard-deviations away from the flaw-free signal; with the best being the lowest time. That is, for a flaw that results in a change in I, becomes equal to the time it takes to reach a value of where is the standard deviation in I. Since, as shown in appendix G, for radiation counting, then is the time for to reach a value of This provides a tradeoff between the decrease in contrast, lower value of with the increase in penetrability, higher value of I. The value of also ensures that the indication due to a flaw is well beyond the statistical fluctuations in the value of I. The value of this figure-of-merit is experimentally measurable. This definition of is particularly useful when the source energy can be varied experimentally; as was the case described in reference [1025], where a tunable high-energy source utilizing a high-energy proton beam on a tungsten target (producing neutrons of energy from 0.1 MeV to 1 GeV) was used. The same concept is also applicable to x-ray machines, where the value of the applied voltage can change, to alter the maximum photon energy. The source energy can also be selected to optimize the resolution or precision of a device. Again in the transmission-based radiographic system discussed above, one can optimize the source energy for the spatial For such a system, using Eqs. (14.21) and (14.9), the resolution, spatial resolution can be expressed as:
670
Radiation Probing, Gauging, Imaging and Analysis
One can take equal to one standard deviation of I, since below this error level, the statistical confidence in the value of I would be quite poor. Using the Poisson statistics of counting, appendix G, along with Eq. (14.21), Eq. (14.24) becomes:
An optimum value for is then obtained when the derivative of with respect to is equal to zero, that is when:
Then the optimum source energy is the energy that results in a value of that is equal to Another way of looking at this conclusion is that the best spatial resolution is obtained when the mean-free-path is equal to half the thickness of the inspected specimen. Interchanging with in the above analysis would have led to the same conclusion, that is the optimum conditions for observing changes in for a fixed thickness, is also when providing then optimum material contrast. Note that the same conclusion is reached from a statistical point view, see section 14.2.
14.4.4.
Interfering Radiation
Radiation sources almost always emit more than one type of radiation. Neutron-emission is usually accompanied by gamma-emission; a gamma-source may also emit beta-particles, while beta-sources may emit photons. Such secondary emissions can interfere with measurements. Therefore, attention must be made to the choice of radiation source and accompanied detectors, in order to ensure that the obtained indications are not greatly influenced by secondary radiation. For this reason, a neutron source may be preferable than an Am/Be source, due to With neutron the lower gamma-field per neutron associated with generators, the detector may be equipped with gamma discrimination electronics (see section 4.5). While gamma-sources can be easily shielded against beta-emission, simply by the material of the source container, it is more difficult to remove gamma-emission from beta-sources since the use of any shielding material will eliminate beta-emissions. Therefore, it is important to choose beta sources with a low gamma yield. In this and are pure (or practically pure, in the case regard, of beta-emitters, while is a beta-source with low gamma emission (0.7%). Although is also a pure beta emitter, its low energy (maximum 18.6 keV) limits its use.
Performance Parameters and Design Aspects
14.5.
671
Selection of Technique
A measurement technique, as explained in Part II, is defined by the nature of its indication, i.e. absorption, transmission, scattering, secondary emission, or a combination of thereof. The modifying physical process, see chapter 3, enables the development of a measurement model that relates the measured indication to the quantity of interest. The availability of a measurement model, not only facilitates interpretation of measurements when a device is operating, but it can also aid the designer in assessing the performance of a device before constructing it. If a measuring device is too complex to enable the development of a measurement model, the designer must rely on detailed simulations or experiments. Some general guidelines for the choice of an indication technique are given here.
Transmission. Transmission is perhaps the most straightforward indication technique, as it has a well-defined path line from the source to the detector, which makes it easy to define the inspected portion of the object. Since transmission relies on measuring uncollided radiation, its indication carries radiation that has the same energy as that of the source; a feature that can be used with monoenergetic sources to eliminate the effect of scattered radiation reaching the detector from the object or surroundings. Also, such energy information in a source of wide spectrum may be used to obtain elemental composition information. However, the information obtained is a “compressed” (integral) indication of the material present within the radiation path line, and is affected by the material thickness. While tomography can “descramble” this compressed information, it requires multiple exposures from many directions. The modifying physics associated with transmission is that of “removal” of radiation from the incident beam, by absorption and/or scattering. Therefore, if a medium is “opaque” to radiation, no useful indication would be deduced. On the other hand, if a medium is too transparent to radiation, the change in indication, caused by changes in the interrogated medium, may be too small to be measurable. Scattering also affects the indication by the “buildup” process that increases the transmission intensity, see section 6.1. The signal-to-background ratio (S/B) for transmission has an upper limit of unity, since the background signal is the transmission indication obtained in the absence of the object. On the other hand, the transmission signal can be quite strong, as it measures the uncollided radiation. Thus the signal-to-noise (S/N) ratio for transmission is quite high.
672
Radiation Probing, Gauging, Imaging and Analysis
Scattering. Perhaps, the main limitation of the transmission method is that it requires access from two opposite sides of the object, a circumstance that may not be available in some situations, as in the case of examining large structures. Backscatter indications can be useful in such applications. The scattering process is normally associated with change in radiation energy, which can be used to distinguish the scattered radiation from that of the source. The energy change in single scattering can also be associated with the scattering angle, as is the case with Compton photon-scattering (section 7.2.1) and neutron elasticscattering (section 7.2.2), providing localized “pointwise” information (section 7.3). Such localization can also be obtained by collimating both the source and the detector to define a small inspection volume, or by utilizing the unique energy-angle relationship of Compton scattering, Eq. (3.37), or that of neutron elastic-scattering, Eq. (3.80). Global inspection is also possible with scattering as it can cover a large volume (section 7.5), if no collimation of the source and detector is used. The lack of collimation enables more efficient use of a radiation source, since radiation collimation is an elimination process that reduces the amount of radiation emanating from the source or reaching the detector. Indeed, one can even argue that scattering is the “natural” way of inspection, since it is the process used by the naked eye to view objects by light reflection. However, a sophisticated interpretation process, provided by the brain in the case of the naked eye, is required to interpret scattering indications. Radiation is scattered from within the medium, unlike light which is reflected only off surfaces. This further complicates the interpretation process. The strength of the scattering signal is quite weak, resulting in a low signal-to-noise (S/N) ratio. On the other hand, the signal-to-background ratio (S/B) can be quite high. Theoretically the S/B ratio for scattering has no limit; if the background signal is brought to zero, S/B for scattering approaches infinity. This enables scattering techniques to provide better material contrast. Scattering also provides three-dimensional information, unlike the two-dimensional (geometric projection) nature of transmission. Emission. The third indication modality is that of secondary emissions, i.e., the emission of radiation which is different in type from that of the source. This is a powerful method for elemental identification, since such emission can be characteristic of the elements involved (chapter 8). However, producing such emissions usually requires an intense radiation source, or a long exposure time, to produce an acceptable signal-to-noise (S/N) ratio. The intensity of emitted radiation is also affected by the distribution of the primary radiation, which in turn is
Performance Parameters and Design Aspects
673
affected by the nature of the interrogated medium. This can make the interpretation of the emitted signal quite difficult, not only in terms of intensity due to the distribution of the primary radiation within the medium, but also by the change in energy of the emitted radiation by scattering within the medium. The signal-to-background ratio (S/B) for secondary emissions can be quite high; approaching infinity since in the absence of the element (s) giving rise to secondary radiation no emission occurs. Therefore, the selectivity, contrast to element(s) of interest, can be quite high. However, activation of elements in surroundings can add to the background signal. Also, interference between elements that give similar emissions can be a problem. In some cases, the detector used may be sensitive to both the primary and secondary radiation, which further complicates the signal analysis process. The primary radiation may also damage the detector of the secondary radiation. Natural radiation emission, or emission from radioactive materials, eliminates the need for primary radiation. However, attention should be paid to the fact that the distribution of the emitting material in a medium also affects the indication signal. Absorption. The absorption indication process, which can be monitored in a variety of ways, as discussed in chapter 9, is mainly useful when interrogating materials that have affinity to absorbing a certain type of radiation. The absorption indication is similar to that of transmission, since both rely on detecting the removal of radiation from the incident radiation. Indeed, transmission techniques are sometimes referred to as absorption techniques. The distinction made here between the two methods is that transmission monitors the signal “transmitted” from the source to detector within a well-defined path through the object. On the other hand, absorption monitors the removal of incident radiation from anywhere the radiation source reaches, including that of scattered radiation. Combined Indications. The use of one type of indication is not exclusive of others. For instance, along with transmission, one can measure the scattered radiation, or even the emitted radiation, since the detectors needed for these techniques do not have to reside at the same location as the transmission detector (s).
14.6. Detection System 14.6.1. Detector Selection As chapter 4 showed, a wide variety of detectors are available for various types of radiation. The choice of a detector for a given application is
674
Radiation Probing, Gauging, Imaging and Analysis
often dictated by the radiation type and energy, and whether a measurement requires a detector with energy-resolution capability. Obviously a high detection efficiency is desirable, but the energy resolution provided by such an efficient detector may not be sufficiently good for the application at hand. A compromise has then to be made between efficiency and resolution. It is advisable to test in the laboratory the operational properties of selected detectors, since those reported by manufacturers are often performed using certain electronic equipment and settings that may not be necessarily identical to those in a different laboratory. Detectors and associated electronics may drift in their settings, and may be affected by field conditions such as heat and moisture. Therefore, routine performance checks should also be conducted to ensure the accuracy and reliability of measurements. In addition to these basic factors, practical specifications such as size, weight, ruggedness, and whether the detector is hygroscopic, and even cost, can be as important as radiation-detection properties. The response of some detectors may also vary with temperature, while some may require special cooling arrangements. In applications where the count rate is high, or the those that require a fast response-time, the detector’s decay time is important as it determines the time beyond which the detector is ready to receive a new signal. If such time is not sufficiently large, signal pile-up will occur, leading to underestimation of the actual count rate. In scintillator detectors, the detector may continue to emit light after the termination of radiation signal, causing an “afterglow” problem that may be problematic in applications with high sampling rate.
14.6.2.
Electronics
The designer of a radiation-device has a variety of electronic systems to chose from, depending on the needs of the devised system, as discussed in section 4.5. The designer may also be involved in providing the specifications required for the miniaturization of electronics for field use. In experimental testing of a developed device, one almost always is faced with the task of selecting the proper settings for various components of the electronics system, such as the pulse shaping-time, the amplification level, the lower window for discriminating against electronic noise, etc. Problems such as pile-up of signals, dead-time losses and signal timewalk may also be encountered. Section 4.5 provides some guidance on dealing with such problems, but the user’s experience and familiarity with the system is crucial in selecting such parameters.
Performance Parameters and Design Aspects
14.6.3.
675
Detector Collimation
In some applications, detector collimation may be necessary to confine the field-of-view of a detector to a certain direction or region in the inspected object. The principles discussed in section 15.1 for source collimation are equally applicable to detector collimation, except that the detector is placed at the receiving end of the collimator, rather than at its entrance as is the case with source collimation. Therefore, a collimator converging in geometry towards the detector is preferable as it allows radiation to reach the detector without colliding with the walls of the collimator (hence losing energy). A converging collimator also confines the exposed surface of the detector to a small area, see for example references [209] and [230]. Slit and Pinhole. When it is possible to cut-off radiation with a thin material, as in the case of charged-particles and photons, slit and pinhole collimators can be used. These collimators are of a very small length, L, thus they do not provide much collimation in terms of direction, but they can control the projection of radiation on a detection (or imaging) plane, as shown in Figure 14.1. As the same Figure shows, the sides of a slit collimator are parallel, while the pinned nature of a pin-hole collimator enables it to receive and deposit radiation over a wider fieldof-view. Nevertheless, the two collimators are quite similar and their names are often used interchangeably. With low-energy radiation, a slit collimator can be also used. This is simply a narrow slit in a thin plate through which radiation can pass. Also similar to the Soller source collimator discussed in section 15.1.2, a multi-slit collimator can be used. This type of collimator is known as slat collimator [158], and allows the detection of well-collimated radiation arising from the object at adjacent locations. Such a collimator is, therefore, useful in systems requiring precise directional information, as in the case of transmission-computed tomography discussed in section 6.4. Magnifying and Minifying. To decrease the divergence of radiation, a long collimator must be used, as is the case with source collimation discussed in section 15.1. A a narrow hole drilled in to the collimator’s material will provide a pencil-beam collimator. The collimator’s length should be such that only radiation incident on the hole in a direction perpendicular to its cross-section will pass through. When the holes are all parallel to each other, the collimator is called a parallel-hole collimator. The collimator hole can be shaped as a cylindrical, or a rectangular duct to provide a pencil-beam collimator. A collimator that converges towards the source of radiation (arising from the object) can
676
Radiation Probing, Gauging, Imaging and Analysis
be also be used, to reduce the size (“minify ”) radiation projection on the recording medium. Alternatively a diverging collimator can be employed to magnify the projections [158], see Figure 14.2.
Performance Parameters and Design Aspects
677
Foucsed. A collimator with many holes is called a multibore collimator. Such a multihole collimator system can also be utilized to provide multiple individual projections. When a multibore collimator consists of holes that converge towards the detector, it is called a focused collimator [158], as it minifies the projected radiation towards a small area on the detector. On the other hand, a magnifying multihole collimator can be used to increase the size of the projection of radiation on the detection plane.
Manufacturing. The material used for constructing source collimators, see section 15.1, can also be used for manufacturing detector collimators. However, usually a single source collimator is needed, unless the source is quite wide to enable the use of multiple collimators. Multiple adjacent collimators are, however, more often used with detectors, since large-size detectors and imaging plates are readily available. The manufacturing of such collimators can be difficult, particularly when using lead, but tungsten, steel, tin, aluminum, or even graphite are used; with the lighter material more suited for lower energy photons. Photon collimators are usually made of lead, but lead is a soft material that is difficult to machine, while casting lead does not usually produce precise collimators.
Reference [1213] reported an interesting method to fabricate a highresolution collimator with a large number of rectangular slots (49) for detectors employed in Compton scatter imaging (see section 7.6). The method involves first defining the volume to be left empty in the body of the collimator, i.e. the volume that constitutes the shape of the collimated radiation, with carbon-epoxy strips, manufactured one-by-one by polymerization under press between two plane plates. The manufactured strips were then held in place by wedging them at each end into holes precisely machined (with a laser beam) into epoxy-resign plates. The two support plates and the carbon-epoxy strips formed a mould, within which tungsten powder impregnated with epoxy resign, was slowly lowered, while vibrating it to ensue high-density of powder, achieving a density close to that of lead. The strips were then removed by expanding the mold by warming it up, allowing easy removal of the strips. Another method for manufacturing precise collimators was reported in reference [1214]. The method involves the use of foam sheets, thin film adhesive, along with lead foils (with 2% antimony and 0.5% tin), stacked together to form one-dimensional parallel and converging slice collimators.
678
Radiation Probing, Gauging, Imaging and Analysis
Energy Discrimination. Detector collimation may also be provided by energy discrimination when possible. This “soft” (or electronic) collimation process is possible when monitoring monoenergetic radiation. The fact that radiation did not change energy from its point of origin to the detector is an indication that no interactions have taken place, thus this energy defines the path of radiation from its origin to the detector. This concept of collimation can also take advantage of the unique relationship between energy and angle of elastic scattering of neutrons, Eq. (3.80), or Compton scattered photons, Eq. (3.37), in single collisions of monoenergetic radiation, see for example references [228] and [230]. Attention should be paid, however, to the fact that a detector is not a point, and the energy recorded at a detector may correspond to more than one point of scattering [210]. Coincidence measurement of positron annihilation radiation is also a form of “soft” collimation, since the emitted photons have a unique (511 keV) energy that when monitored in coincidence at two opposite directions define the location of emission. This is the process used in positron emission tomography, see section 8.8.3. Crosstalk. In the simultaneous collimation of array of detectors, aligned next to each other, attention should be paid to the “crosstalk” between detectors, i.e. the effect of radiation scattered by the collimators of adjacent detectors, or by the other detectors themselves. Care should by taken in constructing such collimators so that they are aligned properly with respect to each other and to the detectors.
Although collimators are usually used to confine the field-of-view of the detector to within a particular direction, a collimator also acts as a detector shield that minimizes exposure to background radiation, or radiation from outside the area of interest. Thus detector collimation increases the signal-to-back ground (S/B) ratio. However, at the same time, the strength of the detected signal is much weaker for a collimated radiation than the case if the detector were not collimated. Therefore, detector collimation decreases the signal-to-noise (S/N) ratio, as the detected signal becomes more vulnerable to noise effects.
14.6.4.
Filtration
As in the case of sources, see section 15.2, it is often desirable to filter a certain range of energy of radiation reaching a detector. With an energysensitive detector, this can be achieved electronically by discarding the portion of the detector’s pulse-height corresponding to the unwanted range of energy. This can also be performed numerically after digitally
Performance Parameters and Design Aspects
679
collecting the pulse-height spectrum. It is sometimes, however, desirable to physically filter some of the radiation reaching the detector. Detector filtering is useful, for example, in removing an undesirable component that overwhelms the energy response of the detector. Filtering can also enable the use of detectors that do not have good energy resolution, since such detectors offer higher counting efficiency and are less expensive. All source-filtering methods discussed in section 15.2 are also suitable for filtering detectors, since radiation reaching a detector can be viewed in NDE as an “indirect source” of radiation, modified by the inspected object.
This page intentionally left blank
Chapter 15 SOURCE MODULATION
Commonly available sources can be modulated in direction, energy, or intensity, to better suit the designer’s needs. The reader is reminded here that energy refers to the energy of a single radiation entity (a neutron, a photon, or a charged-particle), while intensity refers to the number of entities emitted per unit time. Section 15.1 discusses the design of source collimators to confine incident radiation to a particular direction. Section 15.2 shows how filters can be used to either confine radiation energy to a certain range or cutoff unwanted portion of a source’s energy spectrum. Methods to alter the energy of neutrons by slowing them down (moderation) are discussed in section 15.3, while multiplication of neutrons to increase their intensity is discussed in section 15.4.
15.1. Source Collimation 15.1.1. Design Parameters Due to the corpuscular nature of atomic/nuclear radiation, at most of its practical energy range, radiation collimation is performed by elimination, i.e. removing radiation from a source by absorption or scattering. Thus collimation is in effect not the most effective way of utilizing a radiation source, since a significant portion of the radiation emitted from the source is lost in the collimation process. A non-collimated source also provides a wider area of exposure to radiation, but that comes at the expense of loss of localization of indication, a desirable feature in probing and imaging. The lack of collimation also results in an increased background, as the source radiation may directly reach the detector and is scattered by the surroundings. Confining a radiation source into a 681
682
Radiation Probing, Gauging, Imaging and Analysis
beam localizes object’s exposure (radiation field) and results in a significant reduction in radiation background, but that comes at the expense of reduced source utilization. Since radiation collimation is provided by elimination, a collimator is a constructed by creating a cavity within a block of material. The size of the block (shielding) material has to be such that sufficient material is provided in all directions to block the passage of unwanted radiation. Therefore, shielding principles can be used to determine the dimensions of the collimator’s body, see section 16.3. However, as shown in this section, there are many factors that affect the design of a collimator. Therefore, numerical simulations and/or experiments should be used to confirm that the design of a collimator meets expectations. Monte Carlo simulations, see section 16.2, are best suited for this purpose, as the method can easily accommodate the collimator geometry and can provide rich information, without extensive experimentation. The characteristics of an ideal collimator are: Spatial distribution: uniform profile across the field of exposure, with a sharp decrease in density at the edges of the field. Energy: the energy distribution of collimated radiation should be identical to that of the source, such that only uncollided radiation should pass through the collimator. Direction: the direction of the emitted radiation should be identical, or nearly identical, to the geometric shape of the collimator’s port (cavity).
A number of parameters needs to be taken into account when designing a collimator. These parameters are: Geometric parameters: (Figure 15.1) source size, distance between source and collimator entrance, collimator length, L, size of collimator’s aperture, D, size of the field of exposure, W and distance from collimator’s exit to the irradiated object, Collimator shape: parallel, converging, diverging, multistaged (sequential combination of shapes), see Figure 15.2. Radiation type and energy: which determines the nature of the material from which the collimator’s body is manufactured.
The above parameters are discussed in this following sections.
Source Modulation
15.1.2.
683
Geometry
The size and shape of a collimator port depends on factors such as the source size, the desirable field size of radiation on the surface of an object, and the proximity of the source and object to the collimator’s ends. Source size is either the physical size of an isotopic source or the size of the target bombarded by accelerated charged-particles in an acceleratorbased generator or an x-ray machine. The source size introduces a penumbra effect as shown in Figure 15.1, where the width of the collimated incident beam increases from W to due to the source size, s. The penumbra effect creates an extended region at the edges of the beam and the penumprofile, as Figure 15.1 shows. As bra effect disappears. The source intensity in the penumbra’s zone, i.e. beyond W, tends to taper off gradually, while within W the source’s intensity tends to be reasonably uniform, as sketched in Figure 15.1. For this reason, it is desirable to have the smallest possible source size. From the geometry of Figure 15.1, one can show that:
and
Eq. (15.2) indicates that the penumbra effect is reduced, i.e. when the source is small in size is small). For a fixed source size, the penumbra effect can be reduced by bringing the object as close as possible to the collimator’s exit (small value of by increasing the collimator length, L, and/or by increasing the distance from the source to
684
Radiation Probing, Gauging, Imaging and Analysis
the entrance of the collimator, or a combination of the these parameters. Note, however, that increasing L and/or comes at the expense of reduced intensity on the surface, due to radiation divergence, see section (3.6.2). Eq. (15.1) indicates that the size of the radiation field at the object, W, depends directly, as expected, on the size of the collimators aperture at the exit, D, and can be increased by reducing L and/or and increasing Note that the above analysis is applied in one plane (cross-section) of the collimator, but the same principles are applicable to any cross-section of the collimator. Typically, however, the dimensions determined for one plane apply to all other planes to provide a symmetric collimator. The field size, W, is determined by the size of an object, for full exposure, or by the size of the area to be projected on the object. Therefore, according to Eq. (15.1), the designer can control the values of L, and for a given source size to achieve the desired value of D. The values of D and L are typically related to each other by the collimator lengthto-diameter ratio, as discussed below. The value of and should be as close as possible to zero to minimize the effect of radiation divergence. Practical considerations typically dictate the values of and i.e. how close the source and the object can be brought to the proximity of the collimator’s openings at both its ends. It may, however, be advantages in some cases to increase the value of to decrease the amount of radiation scattered from the detector towards the desired field of exposure. If the source size is large, the size of the radiation field reaching an object can be confined to a small area by reducing the size of the collimator aperture, D, or by increasing the collimator length, L, as Eq. (15.1) indicates. The radiation source can also be placed away from the collimator entrance, to increase the value of in Eq. (15.1), but that can result in increased radiation background due to the spread of the radiation away from the collimator. However, the decrease in D and the increase in a both result in a reduction in the fraction of source particles utilized in collimation, while the increase in L and result in decreased intensity by divergence. Alternatively, a converging collimator can be utilized, as shown in Figure 15.2, to confine the radiation field reaching the object into a small area. Such a collimator can also act as a partial shielding for the source, if the thickness of the collimator is sufficiently large. An ideally collimated beam of radiation consists of parallel rays. However, since radiation diverges with distance, a perfectly collimated beam is impossible to obtain. Collimation, therefore, results in a cone-shaped beam. However, the magnitude of divergence of that cone can be reduced to such a small value that the radiation emerging from the collimator becomes for all practical purposes a parallel beam. The degree of di-
Source Modulation
685
vergence is measured by the cone’s half-angle which, as can be concluded from Figure 15.1, is the angle of deviation from the central axis of the radiation emerging at the exit of the collimator, when and are all set to zero. The smaller this angle, the closer the emerging beam to being perfectly collimated. This is obviously archived by reducing the collimator’s diameter-to-length ratio. Since this ratio is typically quite small in value, the inverse of this ratio, is often used as a measure of the degree of collimation, with when the beam is perfectly collimated. Note that moving an object away from a collimator, i.e. increasing will lead to a smaller divergence angle. Therefore, often replaces L in the ratio calculations. In the radiography, the distance is taken as the distance from the film to the collimator’s exit [928]. For a short collimator, the angle is called the acceptance angle, since for a point source placed at the entrance at the exit of the collimator defines of the collimator the angle within which radiation is not eliminated by collimation. Shape. The parallel-collimator geometry of Figure 15.1 can be provided with a right-circular cylindrical hole, or a rectangular parallelepiped port in the collimator’s body. However, this parallel geometry can be replaced with a tapered collimator geometry to provide a coneshaped beam, or a fan-beam (a fan-shaped slit). The collimator can take the shape of a diverging (from the source) or converging (towards the object) cone, as shown schematically in Figure 15.2. The tapering geometry of the collimator usually follows the principles of geometric optics. A conical collimator diverging linearly from the source follows more naturally the path of emitted radiation, thus is generally preferred over a uniformly tapered or a converging conical beam [1215], as it produces a more uniform beam and has a reduced penumbra effect. However, a converging collimator is more suited for confining radiation emitted from a large source into a small area on the surface of the object. Radiation scattering on the interior walls of a converging collimator has also a lower chance of reaching the object than in the case of a uniformly tapered, or a diverging, collimator. When it is possible to completely eliminate incident radiation with a thin layer of material, as in the case of charged-particles, and lowenergy photons and neutrons, slit collimators can be used. A number of adjacent slits can provide a wide-beam of collimated radiation, consisting of many narrow individual beams. One common configuration is known as the Soller collimator, named after Soller who introduced this slittype collimator for use in x-ray experiments [1216]. This collimator consists of a number of thin sheets compiled together to form a set of
686
Radiation Probing, Gauging, Imaging and Analysis
long, narrow, rectangular cavities. Radiation can only pass through such slits, with each slit providing a narrow beam of radiation. This type of collimator is obviously useful when a thin sheet of material is sufficient to absorb diverging radiation and radiation scattered off the walls of the slits. Thus metal sheets are used for charged-particle and low-energy photons. For thermal and cold neutrons, metal (aluminum, steel or brass) sheets, coated with a neutron absorbing material such as cadmium, are used, but Mylar blades coated with gadolinia bearing paint are also utilized [1217].
15.1.3.
Beam Profile
The quality of collimation is affected by four factors: (1) the penumbra effect discussed above, (2) the natural diverging nature of radiation, (3) direct radiation leakage through the collimator’s material, and (4) radiation scattering off the internal walls off the collimator’s port. The intensity of radiation exiting a collimator (i.e. the beam profile) is governed by the law of divergence, discussed in section 3.6.2. If a collimator is short, the distance from a source (or its center) to an edge at the exit of the collimator can be considerably larger than that from the center of the source to the center of the collimator’s exit. This produces a significant reduction in beam intensity at the edges of the collimated beam, in comparison to its center. The result is a nonuniform beam intensity distribution. For a longer collimator, the relative change in distance, and consequently intensity, between the center and the edges of the beam is much smaller, producing a more uniform beam. Using
Source Modulation
687
a long collimator, however, reduces the beam intensity as the distance of divergence increases. If the length (and consequently the attenuating thickness of the collimator’s material) is not sufficiently large, the source radiation will penetrate the collimator’s material producing radiation at the edges of the collimated beam. This will distort the beam profile. Radiation reflected off the walls of the collimator can also add to the distortion of beam uniformity. However, the more significant effect of scattering is the lowering of the mean energy of the collimated radiation. The scattered radiation is lower in energy than the source radiation and can reach all points of the beam profile, contaminating the collimated radiation with lower-energy radiation. If for some reason a non-uniform beam profile is not needed, for example to block exposure of radiation to a particular region of the object, the shape of the beam profile can be altered by placing a suitably shaped block of a radiation-absorbing material, (also called a compensator) in the field-of-view of the beam. The purpose of a compensator is to remove some radiation from beam regions where radiation flux is unwanted. Such compensators are widely used in radiotherapy to shape beams to protect vulnerable organs and to compensate for the non-uniformity of the body. Compensators are typically made of strong radiation-absorbing materials, and for fast-neutrons (where no strong absorbers exist) aluminum can be used as it has a good fast-neutron removal cross-section [1218].
15.1.4.
Divergence and Alignment
After constructing a collimator, it is important to ensure that it is properly installed. That is, the source, object and detection system are aligned together. It is also desirable to measure the degree of convergence, i.e. the acceptance angle, to ensure that the collimator is operating as designed. Although the length-to-diameter, ratio can be directly measured, such measurement does not ensure the straightness and alignment of the collimator. A standard method is available for determining the ratio for collimators and for testing for alignment in neutron radiography [1219]. The method relies on observing and analyzing the radiographs of a test object centered at different planes perpendicular to the axis of the beam. A well-aligned beam will maintain the same object geometry at various planes. From the size of the image at different planes, the degree of beam divergence can be calculated. A misaligned beam will produce skewed object images. The approach can be used whenever it is possible to record a radiographic image of the source radiation. Reference [1220] presented an extension of this standard method that also allows the determination of the centerline of the
688
Radiation Probing, Gauging, Imaging and Analysis
beam by monitoring the position of a radiation-absorbing wire on the image.
15.1.5.
Collimation of Charged-Particles
Collimation of charged-particles is relatively easy due to their short range. Thus, a small thickness of a material can completely absorb the source radiation. Therefore, a collimator can be designed by simply containing the source in a container within which a hole in created in the shape of the desired collimator, e.g. a narrow cylinder for a pencil beam. The electric charge of the particles also enables the application of an electric field to direct the charged-particles towards a particular direction. This is the process used in particle-accelerators to drive charged-particles towards the target.
15.1.6.
Photon Collimation
Lead is usually used in fabricating photon-collimators due to its high density and high atomic-number, which gives it a large total crosssection, particularly for photon absorption, see section 3.4. Lead, however, is a soft metal that is difficult to fabricate, while castings is also difficult particularly for accurate and small-aperture collimators. Therefore, steel inserts are usually used to define the domain of a beam port. Even then, ensuring alignment and straightness of these inserts is difficult to achieve. Although tungsten is easier to fabricate, it is an expensive metal. The use of metal makes it also possible to design flexible collimators, that is collimators that provide a varying field-of-view. Although, such collimators are mainly used in radiotherapy to control a patient’s exposure to radiation, they can also be useful in industrial applications requiring a varying field size. A varying-field collimator can be made of a set of adjustable radiation-opaque interleaved vanes, and is known as a multileaf collimator. This collimator can open and close, with the aid of a motor to regulate a collimator’s aperture and its tapering angle. Design aspects of such collimator for medical applications are reported in references [1221], [1222], [1223], [1224], and [1225]. Although a photon collimator-material, such as lead or tungsten, are good attenuators of photons, they also scatter radiation. Scattered radiation can reach the field of exposure, reducing in effect its effective energy since the scattered photons have a lower energy than the source radiation. Section 15.1.7 discusses ways to reduce the effect of scattered fast-neutrons. Some of these measures are also applicable to photons.
Source Modulation
15.1.7.
689
Fast-Neutron Collimation
Collimation of fast-neutrons is not as straightforward as photon collimation, since there are no materials that can completely absorb neutrons, to enable their confinement in a particular shape or direction. Nevertheless, some general methodologies have emerged, arising from the design of neutron radiography devices [1226, 1227] and the earlier use of 14 MeV neutrons in radiotherapy, [1215, 1228, 1229, 1230, 1231, 1232, 1233]. These aspects are summarized below. Due to the lack of a perfect material for fully absorbing fast-neutrons, many neutrons tend to re-emerge from the walls of a collimator. Some of these re-merging neutrons can scatter towards the area of exposure projected by the collimator on the object. Scattering from the collimator walls also produces slow-neutrons (due to collisions within the body of the collimator) that can alter the energy of the extracted neutron beam. This lowers the quality of the extracted beam, which should have the same energy distribution as that of the source. Therefore, the design of a fast-neutron collimator requires paying attention to the collimator as both an eliminator of neutrons and as a scatterer. The design aspects used in other types of radiation are still applicable to the design of a fastneutron collimator, but special attention have to paid to the contribution of neutron scattering by the collimator’s walls. Since there is no effective material for absorbing fast-neutrons, eliminating fast-neutrons can involve the use of neutron moderating materials (see section 15.3), which are used to slow-down neutrons to about the thermal-energy where they are readily absorbed. However, moderating materials are also good scattering materials, as they slow-down by neutron collisions. Scattering associated with these collisions can deteriorate significantly the quality of the beam profile in terms of energy. Therefore, metals are found to be more suitable as collimator material, if the energy-quality of the beam is of a prime importance. Neutrons scattered off the interior walls of a collimator tend to have encountered no more than one collision, and thus would not have lost much energy if scattered by a metal, see Eq. (3.80). It is preferable to use a dense metal to provide a large number of interactions within a small volume, to reduce the size of the collimator’s material. Thus, iron and tungsten are preferred as collimator materials. Lead, although highly dense, is not employed due to its lower neutron cross-section; but it may be used, as a liner of the walls of the collimator’s port, and at the latter stage of the collimator, to provide shielding against any gamma-rays that may have been produced within the collimator’s material by neutron activation. Even with iron and tungsten, a large thickness of metal is required to provide complete elimination of source neutrons, making the collimator length quite large
690
Radiation Probing, Gauging, Imaging and Analysis
(from 0.4 to 0.6 m for 14 MeV neutrons). This increases considerably the weight of the collimator, making it difficult to design interleaved collimators to provide continuously variable field sizes, as in the case of photons. However, reference [1233] presented a variable fast-neutron collimator system, consisting of sets of jaws mounted on non-concentric circular rails that allow movement of the jaws to control the degree of tapering of the collimator. A a computer-controlled multileaf collimator for fast-neutrons has also been recently reported [1234]. Although tungsten is more expensive than iron, it does not leave behind residual activity. The activation of iron by fast-neutrons is via The reaction product, is a gammathe reaction emitter with a half-life of 2.58 hours. This can leave residual radiation for hours following the termination of neutron production with an accelerator, causing some radiological-protection and material handling problems. On the other hand, tungsten has a low activation cross-sections for fast-neutrons. The high cost of tungsten, and the difficulties associated with its fabrication, rule it out in many cases as a suitable collimator material. With an iron collimator, lead can be used, as explained above, to attenuate the gamma-rays produced in the collimator’s material. Scattered neutrons affect the profile of the extracted beam by creating of wide tail (penumbra) at its edge. Scattering from the collimator’s walls is affected by the geometric parameters shown in Figure 15.1, as well as by collimator’s material and the source energy. As the distance, between the source and the collimator’s entrance decreases, the solidangle subtended by the walls of the collimator at the source increases. This, leads to increased neutron scattering near the inner walls of the collimator. However, practical limitations often put restrictions on the distance from the source to the target. Although it is desirable to increase this distance, to reduce scattering, a very large distance decreases also the intensity of neutrons extracted from a collimator, due to the divergence effect. Also a long distance can make it difficult to align the collimator with the source. Moreover, source neutrons that do not reach the collimator’s entrance will scatter in the surroundings, requiring additional biological shielding or radiation protection precautions. A longer collimator, larger value of L, provides more opportunity for source neutrons to scatter from the walls. While a shorter collimator length reduces scattering, it can increase neutron leakage longitudinally through the shielding material, defying the collimator’s main function as a neutron eliminator. The larger the required field-size, W, the larger will be the size of the aperture, D, at the collimator’s exit, as Eq. (15.1) indicates, and the higher the chance that scattered neutrons will reach the object. The
Source Modulation
691
field size is determined by the area of the object that needs to be exposed to neutrons. To reduce scattering, this area should to be as small as possible. The uniformity of the beam profile is easier to attain if the field size is small, since the effect of radiation divergence on the beam profile would not be very strong. However, a small-area results also in an ineffective utilization of the source neutrons, as most of the source particles would have been lost in the collimation process. A small exposure area may also necessitate multiple scans of the object to cover a wider area. As the target is moved away from the collimator’s exit, (large value of a smaller number of the scattered neutrons will be able to reach the target, since scattered neutrons emerge from the collimator at various angles and diverge away from the target. By applying the divergence law (see section 3.6.2), one can conclude that the amount of scattered neutrons in the beam at the target locations decreases as increases. However, moving the object far away from the source reduces as well the intensity of collimated (uncollided) neutrons, due to the same divergence effect. The effect of scattering can be reduced by shaping a collimator so that the amount of scattered radiation reaching the object is reduced. This can be achieved by the use of a secondary collimator placed closer to the source and tapered so that neutrons scattered by this collimator do not directly reach the walls of the second (primary) collimator, without passing through the collimator’s body. This is best achieved by the use of a combination of converging/diverging collimators [1230, 1232], as shown in see Figure 15.3. Neutrons suffering collisions in the walls of the secondary collimator will themselves be collimated to some degree. The widening of the aperture of the primary collimator enables scattered neutrons in the other collimator to leave the collimator without further collisions in the walls of the primary collimator. Even though these neutrons may reach the object, their higher energy (due to the elimination of additional collisions) and their divergence over the length of the primary collimator reduces their effect on the overall quality of the beam profile. This dual-stage collimator increases the total length of the collimator, reducing the intensity of particles at the collimator’s exit, by radiation divergence. In addition, the use of the converging collimator near the source reduces the thickness of shielding material for a certain solid angle, resulting in increased leakage. The collimator’s material and source energy also affect the scattering cross-section, and consequently determine the amount of scattering in the collimator and the energy of the scattered neutrons. Therefore, for instance, a fast-neutron collimator designed for a neutron source
692
Radiation Probing, Gauging, Imaging and Analysis
will not be suitable for use with a 14 MeV neutron generator. As mentioned earlier, both iron and tungsten are good fast-neutron attenuators. One of their advantage is that they both have an angular scattering cross-section for fast-neutrons that peaks in the forward direction. This encourages neutrons incident on the inner sides of the collimator to scatter forward towards the sides of the collimator away from its aperture, which in turn reduces the magnitude of the scattering component at the exit of the collimator. The inclusion of a second-stage collimator (following the primary collimator) made of a hydrogenous material, such as polyethylene, can further slow-down, and consequently absorb, the neutrons scattered from the metal of the collimator [1228]. A further third-stage collimator made of lead can absorb the 2.223 MeV gamma radiation produced by neutron activation of the hydrogenous material, as well as function as a beam trimmer to decrease the penumbra. However, that additional second stage will scatter low-energy neutrons towards the object, and worsen the beam’s quality be reducing its mean neutron energy.
15.1.8.
Collimation of Thermal-Neutrons
Slow-neutrons can readily be eliminated using an absorbing material, such as lithium, boron, cadmium or gadolinium. Cadmium is often used as it is readily available in malleable metallic sheets and it has a well-defined cut-off energy of 0.5 eV. The absorption cross-section of
Source Modulation
693
cadmium increases from a few barns at above 0.5 eV to 7500 b at 0.5 eV, and remain high throughout the thermal-energy range, see Figure 3.6. Therefore, layers of cadmium as thin as 0.5 mm are very effective in removing neutrons below 0.5 eV. Since, there are no readily available sources for thermal-neutrons, these neutrons are produced by the moderation of fast-neutrons, as discussed in section 15.3. Containment moderation, discussed in section 15.3.2, lends itself to neutron collimation, as a large thermalneutron population is generated within the container and can be extracted through a beam port. Therefore, the discussion on thermalneutron collimation focuses here on collimating containment-moderated thermal-neutrons, although collimators can also be used to confine the field-of-view of neutrons slowed-slown by the other two methods of moderation (blockage and reflection) discussed in section 15.3. Beam extraction from a moderating assembly is achieved by creating a beam hole within the assembly to allow neutrons to escape, as schematically shown in Figure 15.4. If the moderating material is made of a liquid (light or heavy water), or a soft hydrocarbon material (paraffin or polyethylene), steel or aluminum can be used to shape the beam port and maintain its integrity. As for other types of collimators, using optical principles in shaping the collimator also helps its uniformity. That is, a diverging conical collimator tends to provide a more uniform beam profile than a converging one or a parallel beam. The aperture of the beam is usually defined by the desired size of the field. The length of the collimator can be extended all the way inside the assembly to where the source is positioned, but this can come at the expense of a high fast-neutron component within the beam. Since there is a number of good absorbing materials for thermalneutrons, such as cadmium, it is possible to reduce the beam’s penumbra by placing extended cadmium sheets at the collimator’s exit to eliminate neutrons directed towards the edges of the beam. The uniformity of the beam can also be improved by lining the inner walls of the collimator’s port with cadmium, or making the collimator walls using a hydrogenous material (such as polyethylene) loaded with a neutron absorbing material, such as boron or lithium. Thermal-neutron absorbing materials on one side of the collimator’s walls will absorb neutrons scattering towards it from the other side of the collimator. This reduces neutron scattering and the penumbra associated with it. In a large-size field, these neutron-absorbing materials can be used as beam compensators to shape the beam profile into any desired configuration. For good beam quality, the presence of both fast-neutrons and gammaradiation in the extracted beam should be minimized. Fast-neutrons
694
Radiation Probing, Gauging, Imaging and Analysis
may be present due to incomplete thermalization of the source’s neutrons, while gamma-radiation may be emitted directly from the source or may arise from the capture of thermal-neutrons in the moderator and/or collimator material. While fast-neutrons cannot be entirely eliminated, since no material can fully absorb them, the presence of fast-neutrons can be reduced by ensuring that some hydrogenous material is present in front of the source before the inlet of the collimator. This can be done by not extending, within the moderating assembly, the beam port all the way to the source location. This material between the source and the collimator’s entrance will provide a cushioning effect by slowing-down source neutrons and scattering them off in all directions before they enter the collimator. Since some neutron detectors are also sensitive to gamma radiation, it may also be desirable to reduce the gamma-ray content in the thermalneutron field. In this regard, the use of lithium on the collimator walls, to improved the uniformity of the thermal-neutron profile, is more preferable than boron. This is because neutron-absorption in boron results in the production of 0.48 MeV gamma-ray from the excited state of and cadmium neutron-capture arising from the reaction also has many lines of high-energy photons, while neutron capture by produces which is not a gamma-emitter. The gamma-field can also be reduced by placing a high-density metal with a low thermal-neutron absorption cross-section around the collimator and in the path of the neutron beam to remove the gamma-radiation while allowing neutrons to path through. Both lead and bismuth are preferred in this regard than
Source Modulation
695
aluminum and steel. Although aluminum is less absorbing of thermalneutrons than iron, it is still 15 times more absorbing than bismuth, and 2.5 times more absorbing than lead [28].
15.2. 15.2.1.
Filtering X-Rays
X-ray filtering aims at either producing monoenergetic photons from an x-ray source, or eliminating the low-energy tail of the x-ray spectrum to increase the effective energy of emitted photons. One way to produce a monoenergetic beam of photons is to use an x-ray machine equipped with a secondary target that emits characteristic fluorescence x-rays, see section 2.2.2.2. However, filtering can also be used for this purpose. Different methods of filtering are discussed below.
15.2.1.1
Balanced Filters Balanced filters aim at isolating characteristic radiation from the rest of the continuous spectrum of an x-ray machine, see section 2.2.1. Such a peak can be isolated by applying two materials with absorption (K) edges in their photoabsorption-cross section just below and just above the energy range of of the x-ray target, where the photon flux peaks. The photoabsorption cross-section decreases with energy, in accordance to Eq. (3.30), until it reaches the K-edge (i.e. the energy equivalent to the K-shell of the electron in the atom), where it increases sharply, then drops again according to relationship (3.30) following the absorption edge, see Figure 8.2. Consequently, the amount of radiation transmitted through a filter will increase continuously with energy until it reaches an energy equal to the K-edge of the filter, where it abruptly drops to a very low value, after which it increases again with energy. Therefore, if two filters are chosen so that the difference in their transmission is maximized at their K-edge energies, and minimized everywhere else, maximum transmission will occur at the energy range around the characteristic K edge of the target of the x-ray machine. This condition of maximizing the difference is mathematically expressed with the aid of Eq. (6.1) as, For
which requires that
maximize:
and leads to:
Radiation Probing, Gauging, Imaging and Analysis
696
where the subscripts 1 and 2 refer to the two filters, is the source is the intensity of radiation transintensity at the K-edge energy, mitted through the filters, is the value of the total cross-section at is the thickness values the K-edge energy, is the filter thickness and at maximum difference of transmission between the two filters. The other desirable feature of no-photon transmission outside the energy band defined by the K-edges can be expressed mathematically as: For
which leads to, where is the source intensity at energy indicates that the integral is performed outside the energy range defined by is some effective-energy, the K-edge cross-sections of the filters, and see appendix F, that reduces the integrals in Eq. (15.5) into equivalent simple exponential terms. Obviously, the optimum conditions of relationships (15.3) and (15.5) cannot be attained simultaneously, since the first condition requires that both filters have the same thickness, while the latter condition requires different values. Nevertheless, near-optimum conditions can be obtained by selecting near-optimum thickness values. Then if an energy spectrum, is collected with the first filter, and a spectrum is measured in the presence of second filter (in place of the first filter), the difference should be maximum at photon energy between and minimum everywhere else. Therefore, this filter requires and balancing the source at all energies expect within the desired energy band, hence the name “balanced filter”. For commonly used x-ray machines employing tungsten, the energies lie in the range from 59.31 to 57.97 keV, providing in effect a peak at about 59.5 MeV. Then yttrium, with a K-absorption edge at 61.30 eV, or thulium with a K-edge at 59.33 keV, can be used for one filter to define an upper energy-bound of the filter window, while erbium, K-edge at 57.48 keV, can define the lower energy window [1235].
15.2.1.2
Difference Filters
The balanced filter discussed in section 15.2.1.1 relies on the abrupt change in the attenuation-coefficient which occurs around an energy corresponding to the K edge of the filter material, thus it cannot be used at
Source Modulation
697
energies higher than about The difference filter overcomes this hurdle by using two filter materials that are equally absorbing of photons up to some cutoff energy but one is more absorbing than the other at where E is the photon energy. This is achieved by choosing filter materials that differ considerably in their photon-absorption cross-section at the energy that needs to be filtered out, and using the difference in the count rate recorded in the presence of each filter alone in front of the source of radiation. The fact that the photoelectric effect for uranium dominates over other reactions, even at 500 keV, makes it a suitable filter for isolating the 511 keV photon energy associated with positron annihilation [736]. The other filter needs to be made of material dense enough to remove photons below typically a metal. If the two filters are designed so that they equally transmit photons at then the following condition must be satisfied:
where the exponential factors quantify the amount of attenuation provided by each filter, neglecting scattering, the number refers to the two is the total cross-section at and is the filter thickfilters and ness. The relative difference between counts of the two filters at 511 keV, can be expressed as:
where S(511) is the unfiltered count at 511 keV, and is the total cross-section at that energy. The left-hand-side of Eq. (15.8) represents the filter’s efficiency, i.e. the number of counts recorded by the difference filter versus the count obtained with an equally efficient energy resolving detector. Therefore,
Using Eqs. (15.7), (15.8) and (15.9), one can show that the optimum
conditions for maximum difference between the two filters occur when:
1
The largest K edge of all naturally occurring elements is that of uranium and is equal to 116 keV.
698
Radiation Probing, Gauging, Imaging and Analysis
Reference [736] reported, for optimum foils thickness of 2 mm (uranium) for the first filter and 3.8 mm (tantalum) or 13 mm (silver) for the second filter, for maximum difference in counts at 511 keV. A difference filter can also be designed using foils made of the same material by reducing the counting time associated with the less absorbing detector. In this “same-material difference filter”, the counting periods of the two filters, and are chosen such that their integrated counts at are equal, that is:
where is the unfiltered count rate at and is the total crosssection of the filter material. Then, the relative difference in counts at can be expressed as:
Eq. (15.12) clearly shows that the larger the value of the greater the difference, Note that for optimum conditions, i.e. zero difference at the thickness of the second filter for a given value of must be determined using Eq. (15.11). With a uranium filter of thickness and a relative counting period of with in for a uranium metal 18.900 density, Eq. (15.11) gives a value of for the second uranium filter. Reference [736] numerically demonstrated that this unbalanced difference filter substantially increases the filter’s efficiency, i.e.
15.2.1.3
Cutoff Filters
It is often desirable to cut-off the low-energy tail of x-ray photons, to ‘harden’ the spectrum, i.e. increase its effective energy. The common way of achieving this is to place a thin layer of filter material in front of the source, or in some cases in front or the detector, or film in the case of radiography. Lead is used for this purpose. The thickness of the lead filter is in order of a mm, 0.25 mm for 150 kV x-rays, up to 1.5 mm for 1 MV x-rays [7]. These low-thickness values allow absorption of the lowenergy photons without much energy reduction, by Compton scattering in the filter, of higher-energy photons. Combinations of lead and tin, as well as of tungsten, holmium and neodymium, have been used.
Source Modulation
15.2.2.
699
Neutrons
Neutron filtering aims at either removing neutrons of a particular energy-range (absorption filter), or allowing neutrons of a certain energy range to pass through while damping the rest of the energy spectrum (a pass-through filter). Some of these filters are discussed below, based on their acting energy range.
15.2.2.1
Fast Neutrons
Fast neutrons are quite difficult to filter out since there is no material that can fully absorb high-energy neutrons. Nevertheless, there are some elements that have a strong influence on fast-neutrons. For instance, iron has the ability to reduce neutron energy by inelastic scattering down to about 0.845 MeV [176], at which inelastic scattering ceases to occur (cutoff energy of inelastic scattering). Therefore, iron can be used to shift the neutron energy of a fast-neutron source towards lower energies. An iron layer of about 100 to 120 mm in thickness is required for this purpose [24]. Bismuth is also used as a pass-through filter for neutrons while reducing the gamma radiation associated with neutron production. Bismuth is preferred over lead for removing the gamma radiation, associated with neutron production, because of its smaller neutron crosssection. Reference [1236] proposed the use of 100 mm of bismuth for neutrons extracted from a reactor. Silicon is particularly useful for filtering out fast-neutrons while allowing thermal-neutrons to pass through, as it has a low cross-section for slow neutrons but a reasonably high cross-section for fast-neutrons via the reaction [1237]. The strong dip in the neutron cross-section of oxygen at 2.37 MeV [176] can be used as a pass-through filter to produce neutrons at this energy [29, 1238]. However, because of the low density of oxygen, a large thickness is required, even when liquid oxygen is used. Moreover, is transformed to upon irradiation, presenting an explosive hazard [29].
15.2.2.2
Epithermal Neutrons
Absorbing. Epithermal neutrons are easier to filter out because of the resonances in the cross-section encountered in many elements in this neutron-energy range. Materials that exhibit high (kilobarn) resonances in their absorption cross-sections include indium, silver and rhodium; with filter energy ranges as listed in Table 15.1. In addition to the elements listed in Table 15.1, the following can be (125 eV), used as absorption filters: natural CsI (5.6 eV), (2.850 Kev) (335 eV, 1.098 keV, 2.335 keV), Cu (578 eV) and
700
Radiation Probing, Gauging, Imaging and Analysis
where the energy in brackets is the dominant resonance energy [1239]. Reference [37] also listed Hf (1.10 eV), (1.06 eV), Ir (0.66 eV), Er (0.58 and 0.46 eV), Eu (0.39 eV) and as absorption filters. Many other elements with resonant absorption cross-sections can be utilized for filtering, as usually done in activation analysis, see section 8.1.3. Uranium has also four, strong and well defined, resonances, at 6.671, 20.872, 36.680 and 66.020 eV that can be used for filtering [72]. For example, reference [1240] reported the use of tungsten and sodium as filters to reduce the interference of these two elements in the activation analysis of geological samples. Absorbing filters can be used in inverse-filtering to obtain monoenergetic neutrons from a source of a wide energy spectrum. This is achieved by a filter-difference technique, where measurements are taken in the presence and in the absence of a filter, with the difference providing a net indication of the neutrons at the absorbing filter energy, or energies. Reflecting. In some applications, it is desirable to reflect back neutrons towards the inspected object. Nickel has a large (resonance) elastic scattering cross-section in the range of 3 to 30 keV, while titanium has these resonances in the range 10 to 30 keV. Thus, either element can be used as a filter that scatters back neutrons, while allowing higher energy neutrons to pass through [1241]. These same filters tend also to absorb low-energy neutrons. In effect, they act a filters that enhance the back reflection of neutrons in the 5 to 24 keV range. Moderating. Producing neutrons in the epithermal range (1 eV to 10 keV) necessitates the elimination of fast and thermal neutrons, and often as well the reduction of the gamma field. This requires the use of a moderating material with a slowing-down power that is not too high to fully thermalize neutrons emerging from a fast-neutron source, but
Source Modulation
701
with sufficient ability to moderate the neutrons to the epithermal range. (sapphire) is used as an enhancer of epithermalIn this regard, neutrons. Reference [1236] reported the use of 400 mm of this material to slow-down fast-neutrons from a reactor to the epithermal-energy, without increasing the intensity of thermal-neutrons. Fluorine is another attractive mild moderator. Fluorine has a relatively low thresholdenergy (116 keV) [27] for inelastic scattering, compared to other elements (typically about 1 MeV). Its inelastic scattering cross-section is also quite high, peaking to about 3 b at 2.7 MeV. This high inelastic cross-section, combined with the relatively high mass-number (10) makes a mild moderator that “softens” higher energy neutrons without slowing them down to the thermal energy. Reference [1242] suggested the use of fluorine in a compound or along with an iron pass-through filter, to enhance the production of neutrons in the epithermal-energy range. A combination of Al and F, in the form can also be used for this purpose [1243]. A composite material commercially known as FLUENTAL 2 combines the characteristics of the above materials. This is a mixture of (69%), Al (30%) and LiF (1%), and has a density of [1244]. The absence of hydrogen in this material reduces its moderating ability, while the presence of lithium facilitates the removal of any thermalneutrons without subsequent emission of gamma-rays. Lithium fluoride also lowers the porosity of the material, to achieve a higher density. The relatively high density of the material gives it also some gamma removal absorbs some of the epithermal-neutrons, due capacity. Note that nature of neutron absorption, where E is the neutron energy, to the see section 3.5.6.2. However, the amount of neutron absorption can be controlled by depleting the content of lithium. Resonance Pass-Through. Some nuclides exhibit localized minima in their elastic scattering cross-sections, called anti-resonances. These minima result from the interference of the s-waves of potential scattering, see section 3.5.6.2, and typically occur at energies below several hundred keV [29]. The minima allow selective transmission of neutrons at energies corresponding to these anti-resonances. The strong resonances that immediately follow these anti-resonance result in the removal of higherenergy neutrons. Iron is one of those elements, as it has a low scattering cross-section window at 24.3 keV, which makes it a suitable filter for producing a beam rich with neutrons at that energy [29, 1245, 1189]. 2
FLUENTAL is produced by VTT – Chemical Technology: (http://www.vtt.fi/ket /ket1 /bnct/fluental.htm, accessed Nov 2002).
702
Radiation Probing, Gauging, Imaging and Analysis
Supplementing an iron filter with Al and S help reduce the content of higher energy neutrons without degrading the quality of the 24.3 keV neutrons [1245]. Scandium provides a similar effect at 2 keV and was used to produce 2 keV neutrons, from nuclear reactors [29, 1245, 1246]. However, windows at higher energies allow faster neutron to pass through the filter, but these higher-energy neutrons can be suppressed using a secondary filter. Reference [1246] pointed out that a joint filter consisting of Sc, of of and of Co is an effective filter for producing 2 keV neutrons with low high-energy content. Also, reference [1245] reported that adding Mg, Al, S, To, V, Cr, Fe and Co to a Sc primary filter improve the quality of 2 keV neutrons extracted from a reactor beam, Other pass-through filters include: (0.060 keV), (0.160 keV), (0.186 keV), (0.400 keV), (0.500 eV), (2.2 keV), (4.0 keV), (4.5 keV), (14 keV), (47 keV), (48 keV) and Si (55 keV and 144 keV ), where the energy in brackets is the resonance-energy at which filtered neutrons are obtained [29].
15.2.2.3
Thermal Neutrons
Absorbing. Thermal-neutrons can be easily removed using one of the many neutron absorbing elements, such as cadmium, boron, lithium, and dysprosium gadolinium, samarium, europium Neutron absorption by most of these filters results in the production of gamma rays, the intensity of which can be reduced using a bismuth filter [1247]. However, lithium does not produce such capture-gamma radiation, as it relies on the reaction with the reaction product being a beta (not a gamma) emitter. Cadmium offers a severe cutoff of neutrons below about 0.5 eV, unlike the other absorbers for which the neutrons absorption-cross section tends to decrease with energy in accordance to the relationship of section 3.5.6.2, where E is the neutron energy. This so-called cross-section, where is the neutron speed, reduces as well the intensity of epithermal-neutrons. An interesting flexible filtering unit for use in neutron radiography is presented in reference [1248]. It consisted of two symmetrically placed cylindrical lead diaphragms plated with cadmium. Half-cones were made inside these diaphragms, and by rotating them the beam diameter can be varied continuously. The unit was also equipped with Cd and In (see Table 15.1) filters that can be moved into the neutron beam to cut-off low-energy neutrons, when needed.
Source Modulation
703
Pass-Through. Silicon has a low cross-section of about 2.3 b up to the resonance range in the keV range [27] where it significantly increases. Bi and Pb exhibit a similar behavior. Therefore, these elements can be used as pass-through filters for thermal-neutrons. A single-crystal silicon is preferred in this regard than polycrystalline silicon, due to the lower cross-section of single-crystal compared to that of polycrystalline silicon (0.3 b versus 2.3 b) [1236],
Softening. The effective energy of thermal-neutrons can also be reduced beyond their corresponding ambient temperature value of dictated by the Maxwell-Boltzmann distribution, Eq. (3.89), where is the Boltzmann constant and T is the medium’s temperature. This reduction (softening) in energy is used in some applications, such as neutron radiography, to increase the neutron absorption of materials where the cross-section is high at lower energies. Also if this softening effect is significant, it can result in the production of cold-neutrons, as discussed below, section 15.2.2.4. Reference [1249] compared the performance of three filter materials for use in neutron radiography. It concluded that a 30 mm thick Be filter has a modest effect on reducing the effective energy from 25 meV to about 21 meV, while 150 mm thick Bi and 150 mm of Pb can reduce that to about 11 meV and 7.3 meV, respectively. However, all these filters, at the stated thickness, reduced the beam intensity by about a factor of ten. These filters also help remove gamma-rays from neutron beams, due to their high atomic-number. A quasi-single crystal sapphire quartz quasi-single crystal bismuth, and single crystal lead fluoride can also be used to soften the thermal-neutrons. However, measurements showed that the quasi-single crystal sapphire at ambient temperature is a better filter than liquid nitrogen cooled silicon (Si), quartz (SiO2) and bismuth (Bi), for discrimination between thermal and fast-neutrons, or for softening the Maxwellian spectrum [1250]. The Bragg cutoff phenomenon discussed in section 3.5.5.1, can used to remove higher energy neutrons from the thermal-neutron spectrum, as it favors the transmission of neutrons below the Bragg cutoff energy. Beryllium has a Bragg cutoff energy at 5.2 meV, and is commonly used to “soften” the spectrum of thermal-neutrons. This comes, however, at a considerable reduction in the overall intensity of transmitted neutrons due to the relatively high cross-section of Be at the thermal-energy. Other materials that exhibit a similar behavior include: C (2 meV), Al (4 meV), Si (5 meV), Mg (2.6 – 2.9 meV), Bi (2 eV), Fe (5 eV), Zr (2.5 – 3 eV) and Pb (2 eV) or their compounds or crystals, where the values in brackets is the Bragg cutoff energy [1190].
704
15.2.2.4
Radiation Probing, Gauging, Imaging and Analysis
Cold Neutrons
Filtering cold neutrons aims at producing neutrons within a certain wavelength range, or removing the effect of higher energy neutrons. Using a single crystal, Bragg diffraction, Eq. (3.66), can be used to produce neutrons of a certain wavelength, hence energy, at a particular direction. This requires, however, judicious orientation of the incident beam and the diffracting crystal, and of course a high quality crystal. The appearance of a single crystal can also be imitated using multilayers of thin films of different scattering cross-sections, acting like a two-dimensional crystal [37]. The Bragg cutoff method of filtering neutrons, discussed above in section 15.2.2.3, can be utilized to reduce the content of neutrons of energy above the Bragg cutoff-energy of the filter material. Polycrystalline materials can be used for this purpose. Cooling such filters assures also a large increase in the neutron population at higher energies [37], hence providing more effective filtering. Commonly used filter materials include beryllium, silicon, sapphire or pyrolytic graphite. For low-cost filters suitable for use in cold neutron radiography, reference [1251] suggested the use of a polycrystalline beryllium filter cooled by liquid nitrogen, long enough (1 m) to discriminate against gamrna-rays. Curved wave-guides can act as filters [37]. Cold neutrons are reflected from smooth surfaces, because the neutron refractive index is slightly less than one, see section 3.5.5.2. Therefore, neutron wave-guides can be constructed from smooth surfaces, typically boron glass plates coated with as it has a large scattering cross-section. However, the critical angle3 below which total reflection occurs is very small, hence the necessity for long guides. Nevertheless, if the wave guide is curved, neutrons of short wavelengths tend to travel along the concave walls of the curved guide, and the guide acts as a filter that passes low-energy (high wavelength) neutrons. In order to suppress fast-neutrons and gammarays, references [1253] and [1252] suggested the use of a 3 m long filter consisting of parallel stacking of curved glass plates covered with The combination of the Bragg reflection of a single crystal single and bending was studied in reference [1254] as a possible means of filtering.
3 The critical angle, is given by where is the wavelength, N is the atomicdensity of the reflecting material, is its coherent-scattering length, rad for and only rad for natural Ni, with in nm [1252].
Source Modulation
15.3.
705
Neutron Moderation
Source energy is determined by the nuclear decay, or nuclear interaction mechanism, that generates radiation. While the source energy cannot be elevated, it can be moderated to a lower energy. For chargedparticles and photons, there is no need to moderate the source energy, since as shown in chapter 2, there is a variety of sources with various energies to choose from. The situation is different for neutrons, where there are no sources that directly produce thermal-neutrons, as indicated in section 2.3.3. Therefore, the discussion on source moderation is limited here to the moderation of neutrons. Also, it may be desirable to soften (i.e. reduce the energy of neutrons) emitted from a particular neutron source. However, it should be kept in mind that moderation is in effect a removal process, in which not only neutron absorption occurs, but also radiation divergence and escape, from surfaces not directly facing the desired field of exposure, take place. Therefore, moderation comes at the expense of reduced utilization of the full strength of a source. The processes of source thermalization and softening is accomplished by the slowing-down or moderation of neutrons emitted from fastneutron sources. Either isotopic sources, or neutron generators, can be used for this purpose. Since in this moderation process, a good number of neutrons are lost, by absorption, divergence and leakage, it is important to choose both a source and a moderating material that provide the highest thermal-neutron flux per unit source. Obviously, a source with lower energy is easier to thermalize, and hence will provide the highest utilization factor (thermal-neutron flux per unit source, for a given moderator). Accordingly, among the common neutron sources, listed in Table 2.14, is the most attractive source for thermalization, as it provides neutrons with low energy. However, the short half-life of this photoneutron-source and the associated high gamma-ray background (see section 2.3.2) are disadvantages that limit its use. The next most suitable source for thermalization is then as it has the second lowest energy among the other common sources listed Table 2.14.
15.3.1.
Moderating Materials
A wide variety of neutron-moderating materials are available. However, the most common materials are light water heavy water carbon hydrides such as polyethylene, paraffin, etc.), graphite (carbon), and beryllium. The moderating ability of such materials is measured by two parameters. The first is called the slowing-down power, defined as:
706
Radiation Probing, Gauging, Imaging and Analysis
where is the macroscopic scattering cross-section of the material, evaluated at the energy at which the neutrons scatter, and is the average logarithmic energy decrement per neutron collision and is given by [28]:
where A is the mass-number of the scattering element. For a compound, is evaluated by weighting the elemental values by the weight fraction and the scattering cross-section. The second parameter is called the moderating ratio, and is defined as:
where is the absorption cross-section of the material at the thermal energy. The slowing-down power measures how well a moderator slows-down neutrons, while the moderating ratio represents the ability of a moderator to slow-down neutrons without absorbing them. Carbon hydrides and water have a large slowing-down power, while beryllium, carbon and heavy water have large moderating ratios. Table 15.2 provides a summary of the above moderating materials, as well as other materials that have special characteristics that make them suitable for use in some applications. For example, provides also shielding for the gamma-radiation emitted along with neutrons. Beryllium, a light metal, is expensive and brittle, but has the lowest absorption cross-section among metals. Water-extended polyester (WEP) is fire resistant, unlike paraffin and polyethylene which have low flashing and melting points. However, one disadvantage of hydrogen-containing moderators is that when hydrogen absorbs thermal-neutrons it produces 2.223 MeV gamma-rays, which require biological shielding and may interfere with neutron counting if the detector used is sensitive to gammarays. Liquid moderators, such as light water and heavy water is quite expensive. It should be noted can leak and evaporate, while that helium would have been a good moderating material, but it is only available as gas and even at high pressure its slowing-down power is too low. Some metals are also attractive as moderators. Although a neutron does not lose much energy per collision upon scattering with a metal (due to the high mass-number of metals), it can encounter many collisions if the microscopic scattering cross-section is high. The high density of metals further enhances the scattering probability, by increasing the macroscopic scattering cross-section. Titanium, nickel and molybdenum are metals that are attractive as moderators, as they have a large (reso-
Source Modulation
707
nance) elastic scattering cross-section [27]. Reference [593] reported the use of a combination of nickel (enclosing the source) and polyethylene to moderate the neutrons of a source. Lead, tungsten and iron, which are used for gamma shielding, have also large inelastic scattering cross-sections, and thus alter the neutron energy. However, tungsten, because it has many possible excitation levels (hence many possible outgoing energy levels), tends to be a more effective moderator of neutrons by inelastic scattering [594]. Uranium and thorium also have high inelastic cross-sections, but at above about 1 MeV produce fission neutrons, which can interfere with their moderating effect. Neutron moderation can be achieved in a number of ways, as schematically shown in Figure 15.5. In the first arrangement, the slowed-down neutrons are produced within the moderating material itself. This is
708
Radiation Probing, Gauging, Imaging and Analysis
called here moderation by containment and requires either a beam extractor to deliver the neutrons to the outside of the moderator, or the introduction of the interrogated object inside the container. Such arrangement is best suited for isotopic sources, which are sufficiently small to be placed in a pool or within a canister containing the moderating material. The second arrangement is simpler and requires only the placement of a slab of a moderating material in front of the source to slow-down neutrons before they emerge from the other side of the slab. This process is called here block-moderation, since the emitted neutrons are slowed-down before emerging from the slab. This arrangement is suited for neutron generators, which are large in size to be placed inside a container. In the third arrangement, the moderating material is used as backing material which reflects, and slows-down, the source neutrons. This arrangement is suited when mild moderation of the source energy is required. The thickness of material through which neutrons have to path until they are slowed-down, depends on neutron-energy, the type of moderating material, and the energy to which the neutrons needs to be moderated. A simple approach is given here to determine an approximate value of the radius of a spherical canister. However, Monte Carlo simulations, see section 16.2, should be used to refine this estimate, assess the use of more than one moderating material, or the employment of other moderation geometries and arrangements. The simple approach is as follows: Determine the average source energy,
say 2 MeV for a
source.
Source Modulation
709
Choose the desired average energy to which the source neutrons are to be moderated, say the thermal-neutron energy, 0.025 eV. Choose a moderating material, say light water, and find the value of its average logarithmic energy decrement per collision, see Table 15.2. For Calculate the average number of collisions to moderate the source using the relationship [28]: neutrons to the desired energy,
For the example values given above, Find the macroscopic scattering cross-section of the moderating material, Since the cross section varies with neutron energy, which changes with collisions, an accurate value is not obtainable using a simple calculation. However, the values tabulated in Table 15.2, which are evaluated at some epithermal energy, can be used as a first approximation, regardless of the source and moderating energies. For Since the mean-free-path of a neutron, i.e. the average distance between collisions, is equal to and collisions are required, the radius of a spherical canister should then be equal to For the above example values, the required radius would be cm, i.e. 134 mm. It should be kept in mind that the above method provides very crude estimates, as it uses average values and in effect assumes that the slowedneutrons are moving in a straight line with same energy, which is of course completely unrealistic. Nevertheless, the obtained values can be used as a first guess in a subsequent numerical simulation study to optimize the design. It should be kept in mind that moderating materials also function as shielding materials, see section 16.3. Reference [1241] investigated the use of a number of moderating materials in a spherical canister arrangement to optimize the design of source. The main conclusion of this study thermal-neutrons from a is that none of the moderators, by themselves, provide optimum thermalization. Moderators with high slowing-down power soften the neutron spectrum more than the same volume of high moderating-ratio material; however, they capture part of the thermalized neutrons. A combination of a high slowing-down moderating material and material with a high
710
Radiation Probing, Gauging, Imaging and Analysis
moderating-ratio is, therefore, desirable. For example, surrounding the source with a small core of material with a high slowing-down power, followed by a high moderating-ratio, such as prosuchas vides an optimum combination. While would soften the neutron spectrum of the source, it would not absorb many neutrons because of its small volume. The softened neutron spectrum is then easier to moderate with the less slowing-down material, without losing neutrons to absorption. Surrounding the assembly with another layer of increases the thermal flux throughout the moderating assembly, by acting as a neutron reflector. The moderating assembly of reference [1241] for the inner layer, 150 mm of for the secutilized 50 mm of ond layer and 100 mm of for the reflector. Using the macroscopic scattering cross-section data of Table 15.2, the first layer will cause on average 6.8 collisions, while the second layer gives 5.25 and the third layer 13.6 collisions, for a total of average number of collisions of 25.65. This number is greater than the 19.6 collisions estimated in the example given earlier for slowing-down neutron from 2 MeV to 0.025 eV using water alone. The additional 6.05 collisions compensate for the lowerwhich is used to reduce neutron absorption. slowing down power of
15.3.2.
Moderating by Containment
Placing a source in the middle of a moderating material is a very effective way for slowing-down source neutrons, as it entraps neutrons within material and increases their chance of colliding with the nuclei of the material. Collided neutrons are also likely to be subjected to more scattering by the surrounding material, which further enhances the slowing-down process. Since the objective of the process of moderation by containment is to keep most of the neutrons within the container to increase their chance of slowing-down, it is important to decrease neutron leakage. This in turn will reduce the amount of material required and decrease the size of the assembly. For a minimum amount of moderating material, a spherical canister should be used, with the source placed at its center. A sphere offers the smallest surface-to-volume ratio, hence a minimum amount of neutron leakage and maximum retention of neutrons within the system for further moderation. However, it is often more practical to fabricate and handle a cylindrical container. If this is the case, the thickness of the moderating material should remain equal in all directions to the radius of an equivalent moderating sphere placed around the source. This can be done by using a cylindrical canister of a diameter equal to its height, with both being equal to the diameter of the equivalent moderating sphere. Then, the volume of the cylinder, as well its radius,
Source Modulation
711
becomes 1.5 times larger than that of the equivalent sphere that can be inscribed within the cylinder. The increased volume will scatter back some neutron towards the moderating medium, causing more scattering and a slightly increased thermal-neutron flux. Although, the increased volume will also cause more neutron absorption, such absorption would be primarily of neutrons that would have escaped the system if a spherical container were used. Similarly, the increase in the surface area of the cylindrical canister would not increase neutron leakage, in comparison to that of the sphere, since neutrons reaching the surface would have been scattered, or absorbed by the added material in the cylinder before reaching its surface. In summary, the cost of using additional material in a cylindrical canister is somewhat compensated for by the increase in thermal-neutron flux within the assembly. An alternative containment geometry is to place the source in a pool of a moderating material, preferably at the middle of the pool, to increase the effectiveness of the moderation process. This geometry is particularly suited for liquid moderators. Moderating by containment is more practical for use with isotopic sources, due to their small size, but provisions can be made to leave a vacant space within the container to insert the head of a neutron generator. In moderation by containment, the highest thermal-neutron flux is near the center of the assembly, where the source strength is maximum, leakage is minimum and neutron reflection is at its peak. Therefore, to be able to utilize these neutrons, a neutron-beam needs to be extracted out of the moderator, or alternatively the object exposed to the thermalized neutrons can be placed within the container. The latter alternative, though preferable as it enables better use of the thermalized neutrons, is not always practically possible, while beam extraction requires special consideration, as discussed in section 15.1.8. In a moderating assembly, or for that matter a nuclear reactor, a fast and epithermal-neutron beams can also be extracted with the aid of a collimator, see section 15.1.8. The collimator of such an assembly can be equipped with a filter that favors the passage of fast and or epithermalneutrons. A thick (0.4 m) single-crystal silicon was reported to be a good band-path filter for producing thermal-neutrons, as it has a low (0.3 b) cross-section for thermal-neutrons [1236, 1257]. An equal thickness of alumina was also shown to be capable of slowing fast-neutrons to the epithermal energy range, while also reducing the gamma-ray content of the beam [1236, 1257]. A 100 mm layer of bismuth was also found preferable than lead in reducing the gamma-content of the extracted beam, due to the lower cross-section of Bi, compared to Pb.
712
15.3.3.
Radiation Probing, Gauging, Imaging and Analysis
Block Moderation
In this moderation process the passage of source neutrons is blocked by a slab of a moderating material placed in front of the source. This will cause the source neutrons to collide within the slab and lose some of their energy. The neutrons that emerge from the other side of the slab will have an energy distribution that is “softer” (lower in energy) than that of the source. This approach is more suited for neutron generators than for isotopic sources, since the larger size of the generator makes it cumbersome to insert the head of a neutron generator within a container full of moderating material. Moreover, unlike radioisotopes where neutron emission is isotropic, neutrons emitted from neutron generators tend to peak in the forward direction, making them more amenable to block moderation. However, even in reactor beams, block moderation is employed in the form of filtering to favor the generation of epithermalneutrons over thermal ones, or to “soften” the thermal-neutron flux, as explained in sections 15.2.2.2 and 15.2.2.3, respectively. In order to allow a maximum number of neutrons to escape from the block’s moderating material, the area of the surface from which the moderated neutrons emerge has to be as large as possible. This is why a slab geometry is preferred, as opposed to curved geometries. Although, the field of neutrons emerging from the slab will cover a wide area, most of the neutrons will arise from the area closest to the source location, where the neutron intensity is highest. It is also possible to place a beam extractor (collimator), see section 15.1.8, in front of the slab to confine the neutrons. The increase in the surface area of the moderating material comes at the expense of a reduction in the effectiveness of the moderating material, in comparison to moderation by containment, since a larger portion of the neutrons will escape before being subjected to slowingdown. In addition, for isotropic sources, where only neutrons directed towards the slab are slowed-down, the rest of the neutrons, emitted away from the slab, are not utilized. However, the source can be blocked at more than one side, allowing each side to function as a source of sloweddown neutrons. Of course, if the source is blocked in all sides, the blockage becomes in effect equivalent to moderation by containment , as neutrons will be internally reflected from one block to another. In spite of its above mentioned limitations, this moderation arrangement has a number of advantages. It allows easy access to the source, so that the source can be easily retrieved and perhaps used in another application. The method also accommodates the physical size of neutron generators, and allows easy access to them for adjustment or maintenance. In addition, unlike in moderation by containment, there is no
Source Modulation
713
need for the interrogated object to intrude within the moderating material. Although block-moderation is geometrically simple, as it requires only the placement of a slab in front of the source, the determination of the thickness of the slab is not a straightforward task. The thickness of the slab has to be chosen so that it is sufficiently thick to moderate the neutrons, but not too thick to entrap them or absorb them within the block. A too-thin slab will allow most of the source neutrons to pass unaffected by the moderating material, with a few neutrons being moderating, resulting is a slightly softened neutron spectrum. Therefore, a thick slab will absorb most of the slowed-down neutrons within the moderating material. A thick slab may also absorb low-energy neutrons emerging directly from the source, and in effect harden the source spectrum of the neutrons emerging from the other side of the source. This will occur only if high-energy source neutrons can succeed in escaping from the slab, while lower-energy neutrons (from the source or as a result of slowing-down) are absorbed within the slab. Of course, the slab, if thick enough, can become a neutron shield, allowing only a very small fraction of the source neutrons to escape. Due to the competing effects described above, Monte Carlo calculation, see section 16.2, should be used to determine the optimum slab thickness for a given application. Since the scattering cross-section varies from one moderating material to another, as shown in Table 15.2, and it also depends on the neutron energy, the thickness of the slab should be designed for a given moderating material, or combination of materials, for a specific source-energy spectrum. The flux of neutrons emerging from the moderating slab can be seen to consist of two components: (i) those source neutrons that succeed in escaping the slab without colliding with the moderating materials (uncollided component), and (ii) those that are slowed-down by neutron collisions (collided component). The design of a moderating slab should aim at balancing the two components, to achieve the desired level of moderation while maintaining a high neutron output. While minimizing the uncollided neutrons maximizes the removal of high-energy (unmoderated) neutrons, its complete elimination may lead also to a severe reduction in the collided component; an indication that the slab is acting more like a shielding rather than as a moderator. On the other hand, there is a limit to how much one can increase the collided component by increasing the thickness of the slab, before neutron-absorption within the slab starts to remove most of the moderated neutrons. Nevertheless, this maximum collided component is what the designer should aim at, if a well-moderated source is desired.
714
Radiation Probing, Gauging, Imaging and Analysis
A rough guide to determining the thickness of the moderating slab is to use from one third to one half of the required radius of a sphere for moderation by containment, see section 15.3.2. The logic behind this estimate is that, while in moderation by containment a large thickness is needed to moderate and retain the neutrons, block-moderation requires neutrons to leave the system. Therefore, a smaller amount of moderating material has to be used in block moderation. At about one third to one half the radius of a moderating sphere, a sufficient moderation would have been occurred, without a considerable amount of absorption. This rough estimate should be used as an initial guess in a design process, and should be refined according to the specific requirements. One last note on neutron block-moderation, it is a process in which neutrons are delayed. That is, the slowing-down process takes time. Therefore, if a pulsed source is moderated, the duration within which the moderated neutrons are emitted will inevitably be longer than the duration of the pulse generated by the source. This should be taken into account if a moderated pulsed source is to be employed.
15.3.4.
Moderation by Reflection
Neutrons reflected off a moderating material would have encountered a few collisions, and thus moderated in energy. If the source is an isotropic source, the field of reflected neutrons will be blended with unmoderated neutrons emanating from the source away from the reflector. For neutron generators, where the source is biased in the forward direction, the moderating material can be placed in front of the source to reflect back slowed-down neutrons. Neutrons can be reflected back as a result of one collision or multiple collisions. Both will result in a significant loss of neutron energy, since as Eq. (3.80) shows, a large angle of reflection results in a large loss of energy. Multiple scattering compounds the loss of energy, from one interaction to the other. Most of the reflected neutrons are likely to emerge from near the surface of the reflector, since their chance of escaping the moderating material is higher. Theretofore, it is not necessary to use a thick moderating material to achieve good reflection. However, the reflector may be also employed as neutron shield, stopping neutrons from re-emerging from its other surface away from the source. Then the reflector’s thickness should be determined by shielding considerations, see section 16.3. The thickness of the reflector depends on the type of moderating material. A thickness equivalent to, or less than, one mean-free-path of the source neutrons in the moderating material will allow only one collision, thus providing a minimal amount of moderation. On the other hand, a
Source Modulation
715
thick reflector will permit multiple neutron collisions, resulting in more slowing-down, but the collided neutrons may not be able to scatter back towards the source. In determining the thickness of the reflector, it is advisable to start with a moderating material equivalent to one meanfree-path of neutrons at the average source energy, then examine the effect of increasing this thickness. Note also that a metallic reflector may be useful for scattering back neutrons toward the source without affecting much their neutron energy. This allows the reflector to act as a source intensifier, if the source is isotropic, by reflecting neutrons (that would have been otherwise wasted) back towards the object. Note that albedo, a term borrowed from optics, is used by some workers to quantify the reflection process. Albedo is the ratio between the radiation current reflected from a surface to the incident flux density [70]; see section 3.6 for the difference between flux and current. The albedo coefficients reported in the literature are usually obtained by performing Monte Carlo calculations. Since these coefficients were intended for use in shielding calculations, they were reported in units of radiation dose [70]. The albedo values were useful in the past when access to high-speed computers, to perform the calculations, was limited. With the advent of computers and Monte Carlo codes, it is advisable to perform radiation reflection calculations for the particular problem at hand, rather than utilize values reported by others, so that the problems’s special geometry and material can be properly taken into account. Section 16.2 provides some basic information on the Monte Carlo method. Moderation by reflection occurs involuntary in the shielding process, as neutron shielding materials are at the same time moderating materials, see section 16.3. The shielding material around a source reflects back moderated neutrons, which interfere with the neutron field of the source neutrons, if the source is isotropic. This effect can be minimized, if this is undesired, by using a neutron-absorbing element, such as boron or lithium4, within the shielding material, or wrapping its surface with cadmium, to prevent thermal-neutrons from emerging from the shielding. Eliminating reflected neutrons with higher energy is difficult to attain, as they cannot be easily absorbed. However, keeping the shielding at some distance away from the source will tend to reduce their blending with the source neutrons, as the reflected neutrons will diverge over a wide angle.
4
Hydrogenous containing boron or lithium are commercially available, see for example “www.reax.com”.
716
15.4.
Radiation Probing, Gauging, Imaging and Analysis
Neutron Multiplication
The intensity of a neutron source can be enhanced by inducing fission in a target made of a fissile material. Since readily available neutron sources emit fast, or intermediate energy, neutrons, see section 2.3, a material in which fission can be caused by such neutrons is required. The energy spectrum of the resulting neutrons will have a fission spectrum, similar to that of the spontaneous fission source of neutrons, see section 2.3.1.2. Therefore, conversion of a source spectrum to a fission spectrum can be achieved in this process. For example, neutrons emitted from a 14 MeV neuron generator can converted to fission neutrons, which are easier to moderate than the original neutrons, by directing the generator’s neutrons toward a fission target and utilizing the emerging neutrons as a converted source. As Table 15.3 shows, fast fission (at some representative energy range) can occur in both isotopes present in natural uranium, and as although thermal-neutron fission is much more probable well as in and The fission cross-section of and at the for thermal-energy is zero, or is essentially zero, since the fission of these nuclides require an energy of at least 1 MeV [28]. Therefore, the presence of a moderating material in front of the source, to slow-down the neutrons, will enhance considerably the fission process. This is the essence of operation of nuclear reactors, which unfortunately are not portable sources suited for in situ applications. However, the positioning of a target of a fissile material in front of an isotopic source or a neutron generator can boost the neutron flux considerably, thus these targets are often called neutron “boosters”. Because of the relative unavailability and restricted use of and its special handling precautions, its not favored for use as a booster target, in spite of its higher fission yield. Natural uranium, which contains, by weight, and 99.28 % concentration) can as well as enriched uranium (with higher be used as boosters. The higher the degree of enrichment, the lower would be the thickness required for the booster to achieve the same level of multiplication. However, even depleted uranium will provide some boosting of the source strength. The wide energy spectrum of the fission neutrons distorts the energy spectrum of the original source neutrons, unless that source was a fission source such as The field of the multiplied neutrons is also wider than the field of the source, as the fission reaction can take place over a volume larger than that of the source itself. Moreover, the decay of the fission products within the booster results in the production of an additional radiation field that may require biological shielding. For a pulsed source, the multiplication process also prolongs the duration of the pulse.
Source Modulation
717
Delayed-neutron emission from the target, following the termination of a pulse, adds also a neutron background component. Nevertheless, neutron multiplication can increase the source strength by about 15 times with a target, up to 50 times with a target. The target sizes mentioned in reference [1258] were a few tens of mm in thickness, with a small target being 20 × 20 × 20 and an infinite target is assumed to have a thickness of 50 mm. These dimensions provide an indication of the range of target sizes that can be employed. In designing a multiplication assembly, care should be taken to ensure that the assembly is subcritical, with where is the multiplication factor. The multiplication factor is the relative increase in the number of neutrons in one cycle of multiplication, i.e. from the time one neutron induces fission in the multiplying medium to the time the generated neutrons are reabsorbed again to cause further fission. The lifetime of a cycle is in the order of a millisecond. A critical assembly 1) can go supercritical if it is not well controlled, while a supercritical assembly is simply out of control and becomes an explosive hazard. For the first cycle of multiplication will boost an original source strength, the number of neutrons to the second cycle to and so on. Therefore, after an infinite number of cycles, the source strength becomes equal to where (with
is the source intensification factor. Eq. (15.17) demonTherefore, strates how a subcritical assembly, intensities the source strength.
718
Radiation Probing, Gauging, Imaging and Analysis
Since the lifetime of a multiplication cycle is in the order of a millisecond, the series of Eq. (15.17) converges rapidly to in a very short time. The value of the multiplication factor depends on the nature of the multiplying medium (the probability of fission and the number of neutrons produced per fission) and on the geometry of the assembly (which determines the escape probability of neutrons from the medium). The model of Eq. (15.17) is a simple model that does not take into account the details of neutron transport within the assembly; it is in essence a point kinetics model. As the detailed Monte Carol study of reference [1244] demonstrates, the intensity of a neutron beam extracted from a multiplying assembly is considerably lower than that predicted by the model of Eq. (15.17). This is because, the model of Eq. (15.17) provides an overall intensifying factor, over the entire volume of the assembly, while neutrons extracted via a beam port within the assembly is mainly affected by neutron multiplication near the port’s boundary. This is because neutrons produced away from the port are screened from the beam port by self-absorption within the multiplication assembly. Therefore, the model of Eq. (15.17) is a first approximation that should be followed by more detailed analysis and/or experimental measurements. Aside from fission, the intensity of fast-neutrons can also be increased by reflecting neutrons towards the object, by surrounding the object with a material that is a good fast-neutron scatterer. Such a scatterer should not alter the energy of the neutrons, nor absorb a considerable amount of neutrons, otherwise it defies the purpose of enhancing the fastneutron field reaching the object without changing the source energy. The following elements are good fast-neutron reflectors: nickel, iron, molybdenum, lead, tungsten, and [594]. Fission multipliers can also be useful in applications where a high epithermal-neutron flux component is required. By placing a fission plate converter in front of an object exposed to neutrons, fission will take place immediately in front of the object, exposing it to neutrons richer in epithermal-neutrons, as the calculations of references [1259] and [1260] indicate.
Chapter 16 DESIGN CALCULATIONS
16.1.
Design Parameters
Before performing design calculations, it is advisable to segregate the design parameters in to the following categories: Device: parameters related to source, detector, and geometric arrangement. Object: parameters denning object size, shape, density, composition, homogeneity, etc. Performance: parameters that quantify the accuracy, precision, contrast, sensitivity, resolution, etc. Distortion: parameters that inadvertently affect the performance of the device, such as shielding, surrounding walls and objects, natural or spurious object heterogeneity, etc. The performance parameters are dependent parameters, since their values are determined by other parameters. Some of these parameters are controllable by design or setup, and others are beyond the designer’s or the operator’s influence. Usually a designer is faced with many parameters to deal with. It is advisable to vary one parameter at a time, and study its effect on the performance parameters. One should start with the most important (primary) parameters first, then examine the other less important (secondary) parameters. Design calculations are performed for a number of reasons: Proof-of-Concept: to demonstrate the viability of a new concept or idea. 719
720
Radiation Probing, Gauging, Imaging and Analysis
Optimization: to find the design arrangement that optimizes the performance of a device, in terms of contrast, resolution, or some figureof-merit. Parametric Study: to study the effect of various effect parameters that influence the performance of the device. Measurement Modeling: to establish and verify a measurement model for a particular device. Shielding: to design a suitable radiological shielding. Although the design tasks listed above can be performed experimentally in the laboratory, it is useful to perform such studies numerically to avoid unnecessary exposure to radiation, by performing trial-and-error experiments. Calculations also make it possible for the designer to determine the consequences of a design change in an existing device before implementing such a change, thus reducing the cost and risk of design alterations. There are, however, parameters that can only be studied experimentally, such as determining the reproducibility of results (precision), the effect of the surroundings, signal-processing electronics, and detector performance and drift effects that are difficult to numerically simulate. The most effective methods of performing design calculations is the Monte Carlo method; although analytical programs, such as those of references [213] and [1261], can be used in parametric studies. A brief introduction to this method is given in the ensuing section.
16.2.
Monte Carlo Simulation
The Monte Carlo method approximately solves a problem by the simulation of random quantities. The terminology “Monte Carlo” comes from the city of Monte Carlo in the principality of Monaco, famous for its gambling casinos. The computational algorithm is relatively simple. It consists, in general, of a process for producing a random event. The process is repeated N times, each trial is called a “random walk”, or a history. Being independent of each other, the results of all random walks are averaged together to provide an “estimate” of the quantity of interest. Unlike deterministic methods, the Monte Carlo method provides an answer with an error associated with it, so that a confidence level in the obtained results can be established. The process is similar to performing a scientific experiment and is sometimes called the method of stochastic, or statistical experiments or trials. The designer should, therefore, view the use of the method as “computer experimentation”.
Design Calculations
721
Central Limit Theorem. The essence of the Monte Carlo method is the Central Limit Theorem, also known as the law of large numbers. It states that any sequence of length N of independent and identically distributed random variables, with common mean m and variance will produce a random variable:
that is asymptotically normal i.e. reaches a normal distribution of a mean and a standard-deviation when N approaches infinity. In other words, when N is sufficiently large, the average of will approach a normal distribution. Then, the average value, can be used as an estimate of the random variable, and the statistics of this estimate is governed by those of a normal distribution. The central-limit theorem is, therefore, the backbone of the Monte Carlo method. The value of approaches the true expected value, as the number of trials approaches infinity. The variability of is estimated as:
and is called the sample variance. It is not directly an estimate of the distribution variance, but it can be stated that:
where is the estimated value of
say using Eq. (16.2). The 1 confidence interval in the estimated is defined by the interval where
Since
is not known, the following estimate is used
A useful quantity is the “relative error”, also called the “fraction standard deviation” (f.s.d.), defined as:
722
Radiation Probing, Gauging, Imaging and Analysis
An f.s.d. of less than 0.05 (5%) is usually required in Monte Carlo calculations. As Eq. (16.4) indicates, the value of hence that of the f.s.d., That is, to reduce the value of the f.s.d. by half, is proportional to the number of samples, N, must be quadrupled. Random Walks. Radiation transport is simulated in the Monte Carlo methods by tracking the history of source particles1 as they travel through a medium, encountering various types of interactions. The events experienced by the simulated particles are sampled from probability distributions in space, direction and energy (and time in timedependent calculations) that govern radiation interactions as determined by the cross-sections of the nuclei of the material in the encountered media. For more detail, refer to one of the number of the books that deal with the use of this method in solving radiation transport problems, such as references [1262] [1263] and [1264], Advantage and Limitations. The main advantage of the Monte Carlo method is its ability to handle complex geometries. Its main limitation is that it only provides solutions at specified locations, unlike deterministic methods which give solutions at all points in the space considered. This limitation is not, however, important in designing radiation devices, since in such devices one is interested also in measuring the radiation intensity at specific detector locations. However, in Monte Carlo simulations, unlike in experiments, one can position a “detector” within a medium, without disturbing it. This can enable the designer to gain insight into the radiation transport process, and get better understanding of the underlying physical processes. Codes. The most widely used code for particle transport analysis is perhaps the MCNP code [1265]. The COG code [1266] has also powerful feature that makes it attractive for use in designing radiation devices, as it can “simulate complex radiation sources, model 3D system geometries with ‘real world‘ complexity, specify detailed elemental distributions, and predict the response of almost any type of detector” [1267]. Specialpurpose Monte Carlo codes, as those described in references [1268] and [1269] have also been used. Analytical expressions for the cross-sections suitable for use in Monte Carlo simulations are give in reference [1270].
1A particle here also refers to a photon, which is simulated as an entity analogous to a particle.
Design Calculations
723
Setup. The process of setting up a device design-problem in such a Monte Carlo code is analogous to an experimental setup. One needs a source, detectors, and an object with a certain geometry, size and material. One must be aware, however, of any simplifications made in setting up the Monte Carlo problem and their effect on the results. Unlike in the laboratory, one can eliminate the surrounding shielding, since there is no risk of radiation exposure. The shielding can be added at a later stage to examine its effect on the performance of a device, as part of a parametric study. Monte Carlo simulations also require the user to identify the modifying physical processes to be studied. For instance, in a neutron-transport problem, once can choose to simulate also the gamma-rays emitted following neutron capture or inelastic scattering, or can focus only on the neutron-transport problem. Similarly, electrons generated from photon interactions, and the subsequent secondary reaction they induce, can be examined or ignored. Such flexibility enables the designer to perform separate interaction-effect studies, if so desired. Estimators. Detection in Monte Carlo simulations is achieved by a tallying or scoring processes that estimate the particle fluence, and fluence-like quantities (such as energy deposition). In any of the fluenceestimators, the response function of an actual detector can be used as a multiplier of the particle fluence. Tallies estimate the particle fluence based on: the number of particles crossing a surface, number of collisions within a volume, or the number of track-lengths of particles within a volume, or the probability of particles reaching a point (or a ring) in space. The latter is know as the “expected-value” estimator, since it does not require the simulated particle to reach the detector site, but rather it determines at every scattering event the probability of the scattered particle reaching a detector site. This “point detector” estimator is also known as the “next event estimator”, as it estimates the probability of the next scattering “event” being at the detector site, without actually transporting the particle to the detector’s site. The point-detector estimator is a popular one, as is easy to set-up and enables one to designate many detection locations without having to simulate the detector geometry in details. However, a point detector should not be located within positions where scattering events are expected, since the nextevent probability includes the effect, where R is the distance from the collision point to the detector site, in accordance of the law of divergence (see section 3.6.2). When R is close or equal to zero, the estimated particle-fluence approaches infinity and the point-detector estimator becomes unbounded. One can, however, include an exclusion zone (sphere) around the detector to prevent such singularity-causing scores.
724
Radiation Probing, Gauging, Imaging and Analysis
Random-Walk Termination. Monte Carlo codes also require the designation of some means to terminate a random walk. A random-walk is automatically stopped when a particle escapes the system’s geometry or when it is absorbed. However, the latter option is not usually available, since allowing absorption of particles makes it difficult to track radiation in highly absorbing media. Therefore, a weight of unity is typically assigned to the source particle. The weight is reduced by the non-absorption probability each time a particle encounters a collision. The particle is then allowed to survive and the random walk continues in this so-called “non-analog” process. However, the random walk may be terminated when a particle has low weight, below a pre-assigned cutoff value. Similarly, a random walk may be terminated when a particle’s energy reaches a value below a certain cutoff energy. Time-cutoff can also terminate a random walk that may have exceeded a pre-determined maximum age, with the age being the time since the particle’s generation as determined by its speed and distance of travel. The user has, however, to be careful not to prematurely terminate random walks, to avoid loss of valuable information. When possible, it is preferable to let random walks be terminated naturally as the particle escapes into a “universe” outside the domain of study. The domain of study includes the source, object, detectors and shielding, if present, and some surrounding air space. Often, the designer may want to replace air by “void” when radiation interactions in air can be ignored. This speeds up the computations by avoiding the tracking of particles in air. This also eliminates scatters that may occur in air near the site of a point detector, adversely affecting its response. Number of Random Walks. The total number of random walks must be also specified, or one can equivalently specify the execution time in terms of computer processing units (cpu’s). The required number of random walks (or particles) is determined by the level of acceptable uncertainly, keeping in mind the provisions of Eq. (16.4) that relative where N is the number of samples (random error is proportional to walks). The results of Monte Carlo simulations must also satisfy the requirements of the central-limit-theorem discussed above, that is a sufficient number of histories, N, must be followed to allow the estimated value to be approximately normally distributed. The evidence that a solution has reached a value that satisfies that theorem is that the value of estimated quantity does not change much by increasing the number of histories, i.e. the solution converges, and that the estimate error decreases as N increases. It is also important to ensure that the estimated values are obtained from distributions without “holes”, i.e. sampling is
Design Calculations
725
performed over the entire range of a distribution. The MCNP code [1265] performs a number of statistical checks to ensue that the above conditions are satisfied. When reporting Monte Carlo results, one must state both the estimated quantity and the error associated with it, as done when reporting experimental results.
Importance Sampling. If the required level of accuracy cannot be attained by increasing the number of random walks, one may resort to “importance sampling” or “biasing”. Such biasing techniques are designed to encourage particles to travel towards favored areas, directions, energy, or time intervals, while compensating for this biasing process by adjusting the weight designated to the biased particles. Biasing methods should be applied only by experienced users and after trying a few biasing schemes. Importance sampling is based on the concepts of splitting/ Russian roulette or path-length stretching. In splitting, more particles are created in regions, directions, or energies of importance but with reduced weight, such that the total weight of the created particles is equivalent to that of the split particle. Russian roulette is applied to kill unimportant particles, while allowing the occasional particle to survive with an enhanced weight to make up for the lost particles. Path-length stretching artificially reduces the macroscopic cross-section to allow the particle to penetrate deeper into the material, but with a weight accordingly adjusted to compensate for the lower probability of penetration. The process is also called exponential transformation, since it affects the exponential nature of radiation transport, see section 3.6.3.
Comparison to Experimental Results. Relating the results obtained from Monte Carlo simulations to those provided experimentally is a non-trivial task. The Monte Carlo results are all normalized to one source particle. Therefore, one must know the source strength used in the experiments, which is not usually possible. Experimental effects such as detector efficiency and resolution, surroundings, electronic drift or signal pile-up, can produce results that differ from those predicted by simulations. However, the general trend of the results obtained from Monte Carlo simulations should be similar to those of experiment. If not, one must investigate the cause for the difference. This by itself can point to